0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SFC-HC

SFC-HC

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    HANDY CONTROLLER FOR SF4C

  • 数据手册
  • 价格&库存
SFC-HC 数据手册
Type 4 PLe SIL3 Ultra-slim LIGHT CURTAIN SF4C SERIES Conforming to Machine & EMC Directive Certified Conforming to OSHA / ANSI Certified by NRTL Certified [Excluding SF4C-F□ □(-J05)] Machine safeguarding without sacrificing productivity Ultra-slim Light Curtain The picture is an image. 2012.10 panasonic.net/id/pidsx/global Introducing a Type 4 light curtain that combines high end performance with an ultra-slim enclosure. The SF4C series has been designed to offer a machine safeguarding solution without sacrificing productivity. Its size and shape allow for it to fit efficiently into small machinery while maximizing the usable working space for the equipment operator. Slim 13 mm 0.512 in Min. sensing object: ø14 mm (ø0.551 in) [Beam pitch 10 mm (0.394 in)] ø25 mm (ø0.984 in) [Beam pitch 20 mm (0.787 in)] Operating range: 0.1 to 3 m (0.328 to 9.843 ft) Max. 640 mm 25.197 in Min. 160 mm 6.299 in Hand protection type • Zero dead zone mounting is possible • Close vertical mounting of two units is possible 13.2 mm 0.520 in SF4C (with mounting bracket) 43 mm 1.693 in Previous model (with mounting bracket) * Usable work space is 60 mm 2.362 in wider than previous model. 1 Industry first* * Based on research conducted by our company as of March 2009 Large built-in multi-purpose indicators Large LED bars on each side of the light curtain provide a wide visibility indicator that can be customized for various applications be means of independent external inputs. The indicator can be used as an operation indicator, job indicator, etc. sensing object: ø14 mm ø0.551 in; Finger protection type Minimum Beam pitch: 10 mm 0.394 in Tighter Beam Pitch The finger type has a 10 mm 0.394 in beam pitch which allows additional protection while reducing overall size. Safety distance Hand protection type Finger protection type 102 mm 4.016 in 18 mm 0.709 in Shortened by 84 mm 3.307 in * Calculation based on ISO 13855 with 41 ms or longer being the machinery’s maximum stopping time. * The light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855) Simple Safety Distance Calculations The response time of all finger protection light curtains in the finger type is 9 ms or less. Recalculation of the safety distance is unnecessary for each time light curtain length is changed. 102 mm 4.016 in Shortened by 84 mm 3.307 in Hand protection type 18 mm 0.709 in 100 mm 3.937 in min. * Finger protection type Characteristic safety distance for light curtain Characteristic safety distance for the machinery's maximum stopping time *The light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855) 2 Smart equipment Center mounting on a □30 mm □1.181 in aluminum frame Large multi-purpose indicator 88 mm 3.465 in Previous model Installation is time-consuming Wiring is time-consuming Front opening is decreased 3 Machine safeguarding without sacrificing productivity Slim size for efficient applications Available work space is expanded from the previous model, and productivity is improved. If the machine opening is 500 mm 19.685 in Previous SF4C series Usable work space Usable work space 83 % (414 mm 16.299 in) 95 % (474 mm 18.661 in approx.) Usable work space approx. 12 % UP (60 mm 2.362 in) 43 mm 1.693 in 43 mm (including mounting bracket) 1.693 in 13.2 mm 0.520 in (including mounting bracket) If the machine opening width is 500 mm 19.685 in 13.2 mm 0.520 in If the machine opening width is 500 mm 19.685 in Can be used in a variety of applications for simplified equipment [Large multi-purpose indicator] The bright LED indicators located in the center of both sides of each light curtain can be illuminated green or red by using external inputs. There is no need for setting up a separate indicator, so that equipment is consolidated. Previous SF4C series Location is inconvenient and inefficient Location is convenient and streamlined Look at job indicator Green Red Green / Red Look at “large multi-purpose indicator” Job indicator (prepare separately) External input device Job indicator (Lighting / blinking signal) Power source Power source Light curtain Light curtain SF4C Large multi-purpose indicator Input 1 Startup switch Startup switch Control circuit Operator Input 2 Control circuit Operator Applications Use as an operation indicator Use as an error indicator Use as a muting lamp Light curtain’s presence and operation can be checked at a glance. Confirm errors at a glance. Also, details of the error condition can be checked on the digital display. ●Solid green ●Blinking red Equipment is operating There is no need to buy and install a separate muting lamp. Error present Normal Normal Error blinking ●Solid red Emergency stop Confirm detail of error quickly on the digital display. * SF4C-F□ differs in the position of digital display. Use the handy-controller SFC-HC to change lighting conditions. Refer to p.6 for details * If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handycontroller SFC-HC to change the setting, and connect the muting lamp output wire (red) of this light curtain to an incandescent lamp separately. Refer to p.6 for details 4 From designing and constructing equipment to exporting and maintenance Beam-axis alignment indicators help to reduce startup time The beam channels of the light curtain are displayed in four blocks so that incident light position is shown at a glance. When the beam channel at the bottommost channel (or topmost channel), which is used as a reference for beam-axis alignments, is correctly aligned, the LED blinks red. After this, each block lights red as the beam axes successively become aligned. When all channel beam axes are aligned, all LEDs light green. The display also has a stability indicator (STB) added so that setup can be carried out with greater stability. A B C D 1 block OSSD 3 block STB 2 block Beam-axis alignment indicator The bottommost channel beam axis is aligned 4 block Beam channels are displayed in 4 blocks Only the beam axes of the two lower blocks are aligned STB STB A B C D A B C D Blinking OSSD Light up OSSD The bottommost LED ‘D’ is blinking red The bottom two LEDs ‘C, D’ light up in red All channel beam axes are aligned STB Light up A B C D Light up OSSD Light up All LEDs ‘A to D’ light up in green Furthermore, STB display allows the most stable incident light status* to be confirmed. A single model supports both PNP and NPN polarities reducing model numbers PNP transistor output and NPN transistor output are combined in a single model. Overseas equipment that uses PNP, replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations where the control circuits for a single model are suitable for use worldwide. ■ Polarity can be changed easily by changing wiring When the output polarity setting wire (shield) is connected to 0 V, PNP output is selected, and when it is connected to 24 V, it switches to NPN output. PNP circuit 0V Output polarity setting wire (Shield) NPN circuit 24 V IP67 protection structure An IP67 (IEC / JIS) rating is achieved with an ultra-slim size for protection from environmental factors. Lightweight! The SF4C series is made of resin that is approx. 45 % lighter than the conventional aluminum case type. Its lightweight body eases the burden on the mounting surface of the equipment and contributes to overall reduced weight during equipment transportation or overseas shipment. *Except the cable part PNP / NPN polarity indicator Either PNP or NPN side lights depending on which is selected. Material suitable for manufacturing a secondary battery SF4C body is made of resin and the mounting bracket is made of Stainless Steel (SUS), so materials used are limited. Suitable for manufacturing secondary batteries or for food production equipment. Mounting bracket: SUS304 Mounting screw: SUSXM7 * A fast response time for all models SF4C-H□: 7 ms*, SF4C-F□: 9 ms* The SF4C series reduces the safety distance as well as the calculation work required for the safety distance among models with different beam channels. * When connecting safety sensors (light curtains, etc) to the safety input, the response time will be the total time of connected units. Mutual interference is reduced without needing for interference prevention lines The ELCA (Extraneous Light Check & Avoid) function automatically shifts the scan timing in order to avoid interference. 5 Body case: Polycarbonate alloy * Effective from production in November 2010. Reducing the number of malfunctions caused by extraneous light Double scanning method and retry processing are effective in eliminating the effects of extraneous light. Machine safeguarding without sacrificing productivity Handy-controller SFC-HC enables the user to select a variety of settings SFC-HC Operation of the large multi-purpose indicators can be configured Operation of large multi-purpose indicators (factory setting: mode 0) Large Large Mode multi-purpose multi-purpose Control outputs Muting (OSSD 1 / OSSD 2) function Override function indicator 1 indicator 2 OFF Enabled Enabled High or Low High or Low ON 0 Solid red Solid green 1 Blinking red Blinking green 2 Solid red Blinking green 3 Blinking red Solid green 4 (Note 1) Solid red Blinking red 5 (Note 1) Blinking green Solid green 6 (Note 1) Solid green Solid red Blinking green 7 (Note 1) Solid red Blinking red Solid green Blinking green Notes: 1) The blinking condition is prioritized over the solid condition. Notes: 2) During lockout, it is possible to blink red. Lockout blinking function When lockout occurs Enabled Blinking red Disabled Auxiliary output has selectable output configuration Mode No. Description 0 Negative logic of the control outputs (OSSD 1, OSSD 2) (factory setting) 1 Positive logic of the control outputs (OSSD 1, OSSD 2) 2 For test input enabled: output OFF, For Disabled: output ON 3 For test input enabled: output ON, For Disabled: output OFF 4 For unstable incident beam: OFF (Note 1) 5 For unstable incident beam: ON (Note 1) 6 For muting: ON 7 For muting: OFF 8 For beam received: ON, For beam interrupted: OFF (Note 2) 9 For beam received: OFF, For beam interrupted: ON (Note 2) A For safety input enabled: ON, Disabled: OFF B For safety input enabled: OFF, Disabled: ON C For lockout: OFF D For lockout: ON Notes: 1) The output cannot be used while the fix blanking function, floating blanking function or the muting function is activated. 2) This device outputs the beam received / interrupted state under activating the auxiliary output switching function using the handy-controller irrespective of activating other functions, fixed blanking function, floating blanking function, and muting function. Fixed blanking function which allows selective beam channels to be activated improves productivity Floating blanking function which allows non-specified beam channels to be deactivated improves productivity The SF4C series is equipped with a fixed blanking function which allows specific beam channels to be selectively interrupted without causing the control output (OSSD) to output the OFF signal. This function is convenient for use with applications in which certain fixed obstacles tend to interrupt specific beam channels. Furthermore, this function provides greater safety as the control output (OSSD) will automatically output the OFF signal if the fixed obstacles are subsequently removed from the specific beam channels. 1, 2 or 3 non-specified beam channels can be deactivated. If the number of beam channels that are interrupted is less than or equal to the set number of beam channels, then the control output (OSSD) will not output the OFF signal. This function is useful in the event when the positions of obstacles within the sensing area must be changed during object rearrangement, or when an object passes through the light curtain’s sensing area. Note: When the floating blanking function is used, the size of the min. sensing object is changed. Refer to “PRECAUTIONS FOR PROPER USE” (p.24) for details. A variety of other functions can be selected Setting monitoring function This function allows the user to confirm the details of each light curtain setting. (Note) Protection function Unless the password is not input, any setting change of the light curtain cannot be allowed. The factory setting is set to invalid for the protecting function. Copy function Allows settings details to be copied into other light curtains. In the event that the same setting must be input into several different light curtains, this function will reduce the time required for the input of settings. (Note) Muting lamp diagnosis setting When the muting lamp diagnosis is disabled, the muting function will continue to operate even if the lamp is blown. Note: This setting is possible for SF4C series Ver.2.0 or later. 6 Useful built-in muting control function improves productivity Safety, productivity, and cost reduction [Muting control function] Previous Muting lamps Muting sensors Safety circuit (Safety relay, etc.) Light curtain SF4C series The light curtain has a built-in muting control function that causes the line to stop only when a person passes through the light curtain, and does not stop the line when an object passes through. The muting sensors and muting lamps can be connected directly to the light curtain. Furthermore, the large multi-purpose indicators can be used as muting lamps, which contribute to less wiring troubles, improvement of safety and productivity, and cost reduction. Muting unit Muting lamps Muting sensors Safety circuit (Safety relay, etc.) SF4C series * If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handy-controller SFC-HC to change the setting, and connect the muting lamp output wire (red) of this light curtain to an incandescent lamp separately. Selective muting area [Separate muting control function for each beam channel] The handy-controller SFC-HC can be used to carry out muting control for specified beam channels only. Because individual beam channel can be specified to suit the object, separate guards to prevent entry do not need to be set up. While muting control is active (line operating) HC Line stopped For example, depending on the height of the object, the muting function can be activated for 10 beam channels starting from the bottom most, so that if the 11th or subsequent beam channels are interrupted, it is judged that a person has entered the area and the line stops. Safety measures when objects exit [Exit muting control function] Muting at the exit of a machine is now possible using the handy-controller SFC-HC. Just set a Max. four sec. delay timer on the muting sensors located at the exit. This is efficient for places with no installation space for muting sensors and also reduces cost and wiring. HC Entrance side Exit side Muting sensors are not needed on the exit side! By installing muting sensors only within the dangerous zone and setting up a delay timer on the sensor, muting control is made possible even on the exit side where muting sensors cannot be installed. 7 Machine safeguarding without sacrificing productivity Cost reduction in safety circuit without a safety relay unit Safety circuit is constructed without the need for a safety relay unit [External device monitoring function] Previous The light curtain has a built-in external device monitoring function (such as deposited relay monitoring) and an interlock function. This allows a safety circuit to be constructed so that a separate safety relay unit is not needed, and the control box has become smaller to help to achieve to lower costs. Light curtain SF4C series Monitoring Reset input Safety relay unit Safety relays Motor, etc. Safety relays Motor, etc. Reset input Monitoring SF4C series The light curtain can directly connect to external devices (safety relay, etc) without an exclusive control unit. This allows for simplified equipment, cost reduction, and error prevention. Industry first*! Wire-saving when connecting to safety devices [Safety input function] Contact outputs such as an emergency stop switches or a safety door switches can be connected to the light curtain. Also, by using the handy-controller SFC-HC up to three sets of light curtains can be cascade connected for a consolidated safety output. * Based on research conducted by our company as of March 2009 Direct connection of safety devices SF4C series Previous Safety door switch, emergency stop switch, etc. Monitoring Light curtain Safety door switch, emergency stop switch, etc. 2NC Monitoring 2NC Contactor Safety relays Safety relay unit Contactor Safety relays Motor, etc. A safety relay unit is needed for connecting safety devices other than light curtain. SF4C series Motor, etc. Direct connection of various safety devices is possible for a simplified safety circuit. By using the handy-controller SFC-HC up to three sets of light curtains can be cascade connected for a consolidated safety output. (Note) 2NC Monitoring Contactor Monitoring Safety relay unit Motor, etc. Two safety relays are needed Light curtain for each set of light curtain Three sets of light curtains require three sets of safety relays. 2NC Safety door switch, emergency stop switch, etc. Just two safety relays are enough Monitoring Safety door switch, emergency stop switch, etc. Individual monitoring by auxiliary output Monitoring HC SF4C series Previous Contactor Motor, etc. Outputs of safety devices are consolidated in one unit. SF4C series Individual monitoring on light curtains is possible while the outputs of three sets of light curtains and other safety devices are consolidated in one unit. Note: This setting is possible with the use of handy-controller SFC-HC for SF4C series Ver.2.1 or later. 8 SF4C PRODUCT CONFIGURATION Maintenance is prioritized Pigtailed type (Mounting bracket, connector attached cable) Basic set in one model No. Cable type [Mounting bracket, with 5 m (16.404 ft) cable] Standard mounting bracket MS-SFC-1 (Accessory) Standard mounting bracket MS-SFC-1 (Accessory) 1 2 4 3 Cable 5 m 16.404 ft (discrete wire) Connector attached cable 0.5 m 1.640 ft ORDER GUIDE 1 2 Light curtains Finger protection type Hand protection type Appearance Min. sensing object ø25 mm ø0.984 in Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) (20 mm 0.787 in beam pitch) Type Operating range (Note 1) 1 Pigtailed type SF4C-F15-J05 Beam channel No. 10 mm 0.394 in Number of beam Protective height (mm in) 2 Cable type channels 15 160 mm 6.299 in SF4C-F15 Model No. (Note 2) SF4C-F23-J05 SF4C-F23 23 240 mm SF4C-F31-J05 SF4C-F31 31 320 mm 12.598 in SF4C-F39-J05 SF4C-F39 39 400 mm 15.748 in SF4C-F47-J05 SF4C-F47 47 480 mm 18.898 in SF4C-F55-J05 SF4C-F55 55 560 mm 22.047 in SF4C-F63-J05 SF4C-F63 63 640 mm 25.197 in SF4C-H8-J05 SF4C-H8 8 160 mm 6.299 in SF4C-H12-J05 SF4C-H12 12 240 mm 9.449 in SF4C-H16-J05 SF4C-H16 16 320 mm 12.598 in SF4C-H20-J05 SF4C-H20 20 400 mm 15.748 in SF4C-H24-J05 SF4C-H24 24 480 mm 18.898 in SF4C-H28-J05 SF4C-H28 28 560 mm 22.047 in SF4C-H32-J05 SF4C-H32 32 640 mm 25.197 in 9.449 in Protective height 0.1 to 3 m 0.328 to 9.843 ft Beam pitch 10 mm 10 mm 0.394 in 0.394 in Beam channel No. 10 mm 0.394 in Protective height 0.1 to 3 m 0.328 to 9.843 ft Beam pitch 10 mm 20 mm 0.394 in 0.787 in Notes: 1) The operating range is the possible setting distance between the emitter and the receiver. Receiver cannot be placed in this range Actual operating range 0.1 m of the light curtain 0.328 ft Setting range of the receiver Emitter Receiver 3m 9.843 ft 2) The model No. with suffix “E” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver. (e.g.) Emitter of SF4C-H8-J05: SF4C-H8E-J05, Receiver of SF4C-H8-J05: SF4C-H8D-J05 Receiver 3 4 Mating cables Appearance 9 Model No. SFB-CC3-MU SFB-CC7-MU SFB-CC10-MU For receiver For emitter 3 With connectors on both ends 4 Mating cables With connector on one end Type SFB-CCJ3E-MU Description Length: 3 m 9.843 ft Cable with connector on one end for pigtailed type Net weight: 430 g approx. (2 cables) Two cables per set for emitter and receiver Length: 7 m 22.966 ft Cable color: Gray (for emitter), Gray with black line (for receiver) Net weight: 1,000 g approx. (2 cables) Length: 10 m 32.808 ft Connector color: Gray (for emitter), Black (for receiver) Net weight: 1,300 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in Length: 3 m 9.843 ft Net weight: 190 g approx. (1 cable) 10 m 32.808 ft Cable with connectors on both ends for pigtailed type SFB-CCJ10E-MU Length: Net weight: 660 g approx. (1 cable) Cable color: Gray (for emitter), Gray with black line (for receiver) SFB-CCJ3D-MU Connector color: Gray (for emitter), Black (for receiver) Length: 3 m 9.843 ft Net weight: 210 g approx. (1 cable) The min. bending radius: R6 mm R0.236 in 10 m 32.808 ft SFB-CCJ10D-MU Length: Net weight: 680 g approx. (1 cable) SF4C ORDER GUIDE Spare parts (Accessories for light curtain) Standard mounting bracket Designation Model No. Description • Standard mounting bracket MS-SFC-1 Allows the light curtain to be mounted at the rear with one M5 hexagon-socket-head bolt. Mounting direction of the bracket can be selected between vertical or horizontal (no dead zone). (4 pcs. per set for emitter and receiver) Test rod ø14 SF4C-TR14 Min. sensing object for regular checking (ø14 mm ø0.551 in) Test rod ø25 SF4C-TR25 Min. sensing object for regular checking (ø25 mm ø0.984 in) MS-SFC-1 M5 hexagonsocket-head bolt Purchase separately. Light curtain Four bracket set Four M3 (length: 4 mm 0.157 in) countersunk screws Light curtain Standard mounting bracket MS-SFC-1 (Accessory) M3 (length: 4 mm 0.157 in) countersunk screw with loose-proof agent OPTIONS Mounting bracket NA2-N compatible mounting bracket Designation NA2-N compatible mounting bracket Model No. Description MS-SFC-2 Used when changing over area sensor NA2-N series to the SF4C series. The mounting holes of NA2-N series can continue to be used. Center mounting by a M6 hexagon-socket-head bolt is also possible. (4 pcs. per set for emitter and receiver) • Versatile bracket MS-SFC-3 Two ways of mounting are possible. 1 Rear mounting which enables beam adjustment 2 Dead zoneless center mounting on aluminum frame (4 pcs. per set for emitter and receiver) Intermediate supporting bracket for versatile bracket MS-SFC-4 Used to support the light curtain in the middle. Be sure to purchase it when using MS-SFC-3 on SF4C-F55(-J05), SF4C-F63(-J05), SF4C-H28(-J05) or SF4C-H32(-J05). (2 pcs. per set for emitter and receiver) Versatile bracket MS-SFC-2 Mounting holes for M4 screw Mounting hole for M6 hexagon-sockethead bolt M4 screw Purchase separately. Light curtain Intermediate supporting bracket for versatile bracket • MS-SFC-3 • MS-SFC-4 Mounting holes for M4 screw Mounting hole for M6 hexagon-sockethead bolt Mounting hole for M6 hexagon-sockethead bolt Mounting hole for M6 hexagon-sockethead bolt (Mount on either one) Mounting holes for M4 screw 10 SF4C OPTIONS Control unit Designation Appearance Slim type control unit Model No. SF-C13 Description Use a discrete wire cable to connect to the light curtain. Relay output. Compatible with up to Control Category 4. ●Recommended safety relay Safety relay Panasonic Corporation SF series Item Safety relay SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142) DIN terminal block SFS4-SFD (AG1S847) Note: Contact Panasonic Corporation for details on the recommended products. Type Model No. Contact arrangement Rated nominal switching capacity Min. switching capacity Coil rating Rated power consumption Operation time Release time Ambient temperature Applicable standards With LED indicator SFS3-L-DC24V SFS4-L-DC24V 3a1b 4a2b 6 A / 250 V AC, 6 A / 30 V DC 1 mA / 5 V DC 15 mA / 24 V DC 20.8 mA / 24 V DC 360 mW 500 mW 20 ms or less 20 ms or less -40 to +85 °C -40 to +185 °F (Humidity: 5 to 85 % RH) UL, C-UL, TÜV Y-shaped connector Type Appearance Wire-saving Y-shaped connector Model No. Description SFC-WY1 Wire-saving connector for SF4C-F□-J05 and SF4C-H□-J05. Cables of emitter and receiver are consolidated into one cable for wire-saving. Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield), large multi-purpose indicator input 1, and large multi-purpose indicator input 2 only. Power wire and synchronization wire are connected inside the connector. Interlock is disabled (automatic reset). WY1-CCN3 Cable with connector on one side WY1-CCN10 Cable length: 3 m 9.843 ft Net weight: 200 g approx. (1 cable) Mating cable for Y-shaped connector Cable color: Gray (with black line) Connector color: Black Cable length: 10 m 32.808 ft The min. bending radius: R6 mm R0.236 in Net weight: 620 g approx. (1 cable) By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced. Previous A total of 24 wires Only 7 wires Less wiring mistakes! Reduced wiring time! Easy wiring to Safety PLC, etc. SF4C series SF4C series Safety PLC / Remote I/O Safety relay unit SF-C13 CC-Link Safety system remote I/O unit SF-CL1T264T 11 Y-shaped connector Safety PLC / Remote I/O Safety relay unit SF-C13 CC-Link Safety system remote I/O unit SF-CL1T264T SF4C OPTIONS Product configuration Emitter Receiver Extension cable Extension cable (1 cable for receiver) SFB-CCJ3D-MU (3 m 9.843 ft for receiver) SFB-CCJ10D-MU (10 m 32.808 ft for receiver) SFB-CCJ3D (3 m 9.843 ft) SFB-CCJ10D (10 m 32.808 ft) Pigtailed type 0.5 m 1.640 ft Extension cable (1 cable for emitter) SFB-CCJ3E-MU (3 m 9.843 ft for emitter) SFB-CCJ10E-MU (10 m 32.808 ft for emitter) Cable with connector on one side (Common for all models) Y-shaped connector SFC-WY1 WY1-CCN3 (3 m 9.843 ft) WY1-CCN10 (10 m 32.808 ft) Connector pin layout Connector pin No. Black connector 2 1 8 3 Receiver 7 Emitter 6 4 5 Gray connector Description 1 OSSD 2 2 +24 V 3 OSSD 1 4 Not used 5 Large multi-purpose indicator input 1 6 Large multi-purpose indicator input 2 7 0V 8 Output polarity setting wire (Shield) Wiring diagram of control unit SF-C13 • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively. • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side. Light curtain (SF4C-F□-J05 and SF4C-H□-J05) Light curtain (SF4C-F□-J05 and SF4C-H□-J05) Y-shaped connector WY1-CCN□ +24 V DC Not used (Yellow-green) +24 V (Brown) +24 V DC Y-shaped connector WY1-CCN□ Not used (Yellow-green) +24 V (Brown) Large multi-purpose indicator input 1 (Gray) 0V (Blue) Large multi-purpose indicator input 1 (Gray) Large multi-purpose indicator input 2 (Gray / Black) Output polarity setting wire (Shield) Large multi-purpose indicator input 2 (Gray / Black) Output polarity setting wire 0 V (Shield) (Blue) PLC, etc. OSSD 2 (White) OSSD 1 (Black) OSSD 2 (White) A1 S1 OSSD 1 (Black) L1 RESET (Note 1) (Note 1) FUSE1 FUSE2 (Note 2) S2 S3 S4 X1 X2 X3 13 23 33 41 S1 S2 S3 S4 X1 X2 F K1 Ui SF-C13 control circuit A2 0V INTER_LOCK AUX KA, KB: Force-guided relay F.G. or magnet contactor 33 41 K1 OUT L1L2L3 34 42 KB KB KA N FUSE2 RESET (Note 1) (Note 2) K2 FAULT 14 24 X3 13 23 SF-C13 control circuit K2 OUT L1 (Note 1) FUSE1 A1 F.G. F Ui PLC, etc. KA M 3~ Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated. A2 0V INTER_LOCK FAULT 14 24 34 42 AUX KA, KB: Force-guided relay KB or magnet contactor KA N L1L2L3 KB KA M 3~ Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated. 12 SF4C OPTIONS Handy-controller Appearance Model No. Pigtailed type Mating cable Handycontroller Fix ed Floa bla ting nki Aux blan ng Lig iliary king ht con emoutput trol iss ion FU NC TIO N Control circuit Designation SFC-HC Co de Mo Pr nitor ote Co ct py FUNCTION CA NC EL EN CANCEL TE ENTER R Cable type Handy-controller Cable set +V 0 V Cable set for cable type connection Synchronization – Synchronization + Not used Control circuit SFC-WNC1 FUNCTION CANCEL Terminal block ENTER Handy-controller Metal protection case Applicable beam channels Designation Metal protection case (2 pcs. per set for emitter and receiver) SF4C-H□ SF4C-F□ 8 15 MS-SFCH-8 12 23 MS-SFCH-12 16 31 MS-SFCH-16 20 39 MS-SFCH-20 24 47 MS-SFCH-24 28 55 MS-SFCH-28 32 63 MS-SFCH-32 • MS-SFCH-□ • MS-SFCH-8 Model No. SPECIFICATIONS Light curtain individual specifications Item Model No. SF4C-F□ Type Pigtailed type SF4C-F15-J05 Cable type SF4C-F15 Current consumption No. of beam channels Protective height Large multi- purpose indicator lights off Large multi- purpose indicator lights up PFHD MTTFd Net weight Pigtailed Total of type emitter and Cable type receiver ( ) Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05 SF4C-F47-J05 SF4C-F55-J05 SF4C-F23 SF4C-F31 SF4C-F39 SF4C-F47 SF4C-F55 SF4C-F63-J05 SF4C-F63 15 23 31 39 47 55 63 160 mm 6.299 in 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in Emitter: 70 mA or less Emitter: 75 mA or less Emitter: 80 mA or less Emitter: 85 mA or less Receiver: 80 mA or less Receiver: 85 mA or less Receiver: 90 mA or less Receiver: 95 mA or less Emitter: 105 mA or less Emitter: 110 mA or less Emitter: 115 mA or less Emitter: 120 mA or less Receiver: 110 mA or less Receiver: 115 mA or less Receiver: 120 mA or less Receiver: 125 mA or less 2.29 × 10–9 2.73 × 10–9 3.18 × 10–9 3.62 × 10–9 4.06 × 10–9 4.50 × 10–9 4.95 × 10–9 100 years or more 210 g approx. 270 g approx. 340 g approx. 400 g approx. 470 g approx. 540 g approx. 600 g approx. 600 g approx. 670 g approx. 730 g approx. 800 g approx. 860 g approx. 930 g approx. 1,000 g approx. Item Model No. SF4C-H□ Type Pigtailed type Cable type Current consumption No. of beam channels Protective height Large multi- purpose indicator lights off Large multi- purpose indicator lights up PFHd MTTFD Net weight Pigtailed Total of type emitter and Cable type receiver ( ) 13 SF4C-H8-J05 SF4C-H8 Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05 SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05 SF4C-H12 SF4C-H16 SF4C-H20 SF4C-H24 SF4C-H28 SF4C-H32 8 12 16 20 24 28 32 160 mm 6.299 in 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in Emitter: 70 mA or less Emitter: 70 mA or less Emitter: 75 mA or less Emitter: 80 mA or less Receiver: 85 mA or less Receiver: 90 mA or less Receiver: 95 mA or less Receiver: 100 mA or less Emitter: 120 mA or less Emitter: 120 mA or less Emitter: 120 mA or less Emitter: 120 mA or less Receiver: 135 mA or less Receiver: 140 mA or less Receiver: 145 mA or less Receiver: 150 mA or less 1.66 × 10–9 1.90 × 10–9 2.10 × 10–9 2.33 × 10–9 2.54 × 10–9 2.77 × 10–9 2.98 × 10–9 100 years or more 240 g approx. 300 g approx. 360 g approx. 420 g approx. 490 g approx. 550 g approx. 610 g approx. 630 g approx. 700 g approx. 760 g approx. 820 g approx. 880 g approx. 950 g approx. 1,000 g approx. SF4C SPECIFICATIONS Light curtain common specifications Type Applicable standards Item Model No. International standard Pigtailed type SF4C-F□-J05 North America (Note 3) Min. sensing object (Note 5) Effective aperture angle Supply voltage Control outputs (OSSD 1, OSSD 2) Operation mode Protection circuit Response time Auxiliary output (Non-safety output) Operation mode Protection circuit ELCA function Test / reset input function Interlock function External device monitoring function Safety input function Muting function Override function Environmental resistance Optional functions (Note 9) SF4C-F□ SF4C-H□ JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL 3) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PL e), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 Operating range (Note 4) Beam pitch SF4C-H□-J05 IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3) Japan Europe (EU) (Note 2) Cable type 0.1 to 3 m 0.328 to 9.843 ft 10 mm 0.394 in 20 mm 0.787 in 10 mm 0.394 in 20 mm 0.787 in ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)] 24 V DC +10 –15 % Ripple P-P 10 % or less PNP open-collector transistor / NPN open-collector transistor (switching method) • Max. source current: 200 mA • Max. sink current: 200 mA • Applied voltage: same as supply voltage • Applied voltage: same as supply voltage (between the control output and +V) (between the control output and 0 V) • Residual voltage: 2.5 V or less (source current 200 mA, • Residual voltage: 2.5 V or less (sink current 200 mA, when when using 10 m 32.808 ft length cable) using 10 m 32.808 ft length cable) • Leakage current: 200 μA or less (including power supply OFF condition) • Leakage current: 200 μA or less (including power supply OFF condition) • Max. load capacity: 1 μF (No load to Max. output current) • Max. load capacity: 1 μF (No load to Max. output current) • Load wiring resistance: 3 Ω or less • Load wiring resistance: 3 Ω or less ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal)(Note 6,7) Incorporated OFF response: 9 ms or less, ON response: 90 ms or less OFF response: 7 ms or less, ON response: 90 ms or less OFF response: 9 ms or less, ON response: 90 ms or less OFF response: 7 ms or less, ON response: 90 ms or less PNP open-collector transistor / NPN open-collector transistor (switching method) • Max. source current: 100 mA • Max. sink current: 100 mA • Applied voltage: same as supply voltage • Applied voltage: same as supply voltage (between the auxiliary output and +V) (between the auxiliary output and 0 V) • Residual voltage: 2.5 V or less • Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable) (sink current 100 mA, when using 10 m 32.808 ft length cable) OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the handy-controller SFC-HC). Incorporated Incorporated (reducing mutual interference automatically) Incorporated Incorporated [Manual reset / Automatic reset (Note 8)] Incorporated Incorporated (safety contact) Incorporated Incorporated Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting Degree of protection IP67 / IP65 (IEC) Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –13 to +140 °F Ambient humidity Ambient illuminance Dielectric strength voltage 30 to 85 % RH, Storage: 30 to 85 % RH Incandescent light: 5,000 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Emitting element Material Cable Cable extension Accessories 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each Infrared LED (Peak emission wavelength: 855 nm 0.034 mil) Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy 0.15 mm2 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector 0.15 mm2 12-core heat-resistant PVC cable, 5 m 16.404 ft long Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note 10) MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No. SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. 3) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL / ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards. 4) The operating range is the possible setting distance between the emitter and the receiver. The light curtain can detect an object less than 0.1 m 0.328 ft away. 5) When the floating blanking function is used, the size of the min. sensing object is changed. For details, refer to “Safety distance” (p.24~). 6) The outputs are not “OFF” when muting function is active even if the beam channel is interruped. 7) In case the blanking function is valid, the operation mode is changed. For details, refer to “Safety distance” (p.24~). 8) The manual reset and automatic reset are possible to be switched depending on the wiring status. 9) In case of using optional function, the handy-controller SFC-HC is required. 10) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver). 14 SF4C SPECIFICATIONS Control unit Item Model No. Connectable light curtains Applicable standards Control category SF-C13 Light curtain manufactured by Panasonic Industrial Devices SUNX IEC 61496-1, UL 61496-1, JIS B 9704-1 ISO 13849-1 (JIS B 9705-1) compliance up to Category 4, PL e standards Supply voltage / Current consumption 24 V DC ± 10 % Ripple P-P 10 % or less / 100 mA or less (without light curtain) Fuse (power supply) Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down Enabling path NO contact × 3 (13-14, 23-24, 33-34) Application category Rated operation voltage (Ue) / Rated operation current (le) Contact resistance Contact protection fuse rated Pick-up delay (Auto reset / Manual reset) Response time (Recovery time) Auxiliary output AC-15, DC-13 (IEC 60947-5-1) 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection). Min applicable load: 10 mA (at 24 V DC) (Note 2) 100 mΩ or less (initial value) 4 A (slow blow) 80 ms or less / 90 ms or less 10 ms or less Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) Rated operation voltage / current Contact protection fuse rated Semiconductor auxiliary output (AUX) Output operation Excess voltage category Polarity selection function Pollution degree 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 2 A (slow blow) PNP open-collector transistor • Max. source current: 60 mA On when the light curtain is interrupted II Incorporated (Cable connection allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain 2 Protection Enclosure: IP40, Terminal IP20 Ambient temperature Enclosure material –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F ABS Net weight: 200 g approx. Notes: 1) Where measurement conditions have not been specifed precisely, the conditions used were an ambient temperature of +20 °C +68 °F 2) If several SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 3) Refer to our website for details of specifications. Dilating when SF-C13 units are mounted close together 6 Rated operation current (A) Weight 5 4 3 2 1 0 32 35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F) Handy-controller Model No. Item Supply voltage Current consumption Communication method Digital display Function indicators Functions Ambient temperature Ambient humidity Voltage withstandability Insulation resistance SFC-HC 24 V DC +10 –15 % Ripple P-P 10 % or less (common to light curtain power supply) 65 mA or less RS-485 two-way communications (Specific procedure) 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.) Green LED × 9 (Set function is displayed.) Fixed blanking / Floating blanking / Auxiliary output change / Satety input setting change / Large multi-purpose indicator setting change / Muting setting change / Interlock setting change / External device monitoring setting change / Override setting changing function 60 sec. / Protecting –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure Cable 12-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables) Weight Net weight: 200 g approx. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 15 SF4C I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram I/O circuit diagram Terminal No. of pigtailed type Color code Emitter Terminal No. of pigtailed type Color code Emitter (Brown) +V (Brown) +V (Pink) Test input / 470 Ω Reset input 6.8 kΩ 6.8 kΩ 6.8 kΩ 6.8 kΩ (Red) Muting lamp output 6.8 kΩ 470 Ω (Yellow) Override input *S2 6.8 kΩ Sensor circuit 3 kΩ + – (Gray) Safety input 1 24 V DC % +10 –15 6.8 kΩ (Shield) Output polarity setting wire Internal circuit Receiver 47 kΩ 6.8 kΩ Sensor circuit 6.8 kΩ (Pink) Test input / Reset input 6.8 kΩ 6.8 kΩ 470 Ω 0.47 μF Load (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – Users’ circuit Internal circuit Receiver *S2 *S2 Users’ circuit (Orange / Black) Synchronization – (Orange) Synchronization + (Orange) Synchronization + (Brown) +V (Brown) +V (Gray) Large multi*S2 purpose indicator input 1 (Shield) Output polarity setting wire K1 (Black) Control output 1 (OSSD 1) 470 Ω (Light blue / White) *S2 Muting input 1 470 Ω (Light blue / Black) *S2 Muting input 2 470 Ω (Yellow-green) External device monitoring input K2 K1 (White) Control output 2 (OSSD 2) K2 6.8 kΩ 6.8 kΩ 470 Ω (Yellow-green) External device monitoring input 0.47 μF 6.8 kΩ 47 kΩ 0.1 μF (Black) Control output 1 (OSSD 1) 47 kΩ 0.1 μF (White) Control output 2 (OSSD 2) 47 kΩ 6.8 kΩ 0.1 μF K1 (Shield) Output polarity setting wire *S1 6.8 kΩ (Blue) 0 V 470 Ω (Gray) Large multi470 Ω purpose indicator input 1 *S2 47 kΩ (Gray / Black) Large multi- *S2 470 Ω purpose indicator input 2 K1 (Light blue / White) 470 Ω Muting input 1 *S2 6.8 kΩ (Light blue / Black) 470 Ω Muting input 2 *S2 K2 K2 6.8 kΩ (Blue) 0 V (Blue) 0 V 0.1 μF 6.8 kΩ K1, K2: Force-guided relay or magnet contactor Internal circuit (Yellow) Override input (Orange) Synchronization + (Gray / Black) Large multi- *S2 purpose indicator input 2 6.8 kΩ 0.47 μF 470 Ω (Blue) 0 V Sensor circuit 47 kΩ 47 kΩ 470 Ω 0.1 μF (Gray / Black) Safety input 2 24 V DC % +10 –15 6.8 kΩ 6.8 kΩ (Orange / Black) Synchronization – 47 kΩ 0.1 μF 3 kΩ 6.8 kΩ (Pale purple) 470 Ω Interlock setting input 0.47 μF 0.1 μF (Gray) Safety input 1 6.8 kΩ 0.47 μF (Gray / Black) Safety input 2 (Yellow-green / Black) Auxiliary output + – 3 kΩ (Red) Muting lamp output 3 kΩ 0.1 μF Load (Yellow-green / Black) Auxiliary output (Pale purple) 470 Ω Interlock setting input *S2 0.47 μF 0.47 μF *S1 Sensor circuit 0.47 μF (Shield) Output polarity setting wire Internal circuit Users’ circuit * S1, S2 K1, K2: Force-guided relay or magnet contactor Users’ circuit * S1, S2 Switch S1 • Test input / Reset input For manual reset Vs to Vs – 3.5 V (sink current 5 mA or less): OFF (Note) Open: ON Switch S1 • Test input / Reset input For manual reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON For automatic reset Vs to Vs – 3.5 V (sink current 5 mA or less): ON (Note) Open: OFF For automatic reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON Switch S2 • Interlock setting input, Override input, Muting input 1 / 2, Large multi-purpose indicator input 1 / 2, Vs to Vs – 3.5 V (sink current 5 mA or less): Valid (Note) Open: Invalid Switch S2 • Interlock setting input, Override input, Muting input 1 / 2, Large multi-purpose indicator input 1 / 2, 0 to +2.5 V (source current 5 mA or less): Valid Open: Invalid Note: Vs is the applying supply voltage. 16 SF4C I/O CIRCUIT AND WIRING DIAGRAMS Connection example Basic wiring: Min. operation only This is the general configuration using one set of the emitter and receiver facing each other. The control outputs (OSSD 1 / OSSD 2) turn OFF if the light is interrupted, while they automatically turn ON if receive the light. The auxiliary output is used to invalid the external device monitoring function. The auxiliary output cannot be connected to external devices. Receiver (Red) Muting lamp output (p.21~) Open (Yellow) Override input (p.22) Open (Pale purple) Interlock setting input (p.17~) Open (Brown) +V (Pink) Test input / Reset input (p.18) (Gray) Safety input 1 (p.18~) + (Gray / Black) Safety input 2 (p.18~) – (Shield) Output polarity setting wire (Blue) 0 V (Yellow-green / Black) Auxiliary output (p.20) (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (p.20) (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Light blue / White) Muting input 1 (p.21~) Open (Light blue / Black) Muting input 2 (p.21~) Open (Gray) Large multi-purpose indicator input 1 (p.19) Open (Gray / Black) Large multi-purpose indicator input 2 (p.19) Open Emitter Gray cable Gray cable (with black line) Receiver Emitter 24 V DC % +10 –15 Gray cable Gray cable (with black line) 24 V DC % +10 –15 K1, K2: Force-guided relay or magnet contactor K1, K2: Force-guided relay or magnet contactor Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input (Red) Muting lamp output (p.21~) Open (Yellow) Override input (p.22) Open (Pale purple) Interlock setting input (p.17~) Open (Brown) +V (Shield) Output polarity setting wire (Gray) Safety input 1 (p.18~) + (Gray / Black) Safety input 2 (p.18~) – (Pink) Test input / Reset input (p.18) (Blue) 0 V (Yellow-green / Black) Auxiliary output (p.20) (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (p.20) (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Light blue / White) Muting input 1 (p.21~) Open (Light blue / Black) Muting input 2 (p.21~) Open (Gray) Large multi-purpose indicator input 1 (p.19) Open (Gray / Black) Large multi-purpose indicator input 2 (p.19) Open Disabled (Automatic reset) Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input Disabled Not used PNP Invalid Disabled (Automatic reset) Disabled Not used NPN Invalid PRECAUTIONS FOR PROPER USE Interlock function • You can select whether interlock is enabled (manual reset) or disabled (automatic reset) by the way in which the interlock setting input wire (pale purple) is connected. Interlock function Reset operation Interlock setting input (pale purple) Enabled Manual reset When selecting PNP output: Connected to +V When selecting NPN output: Connected to 0 V Disabled Automatic reset Open Make sure that there exist no operator in the dangerous zone when using the interlock function, which can result in death or serious injury. Interlock enabled (manual reset) • The control outputs (OSSD 1 / OSSD 2) are not turned ON automatically even though this light curtain is receiving the light. When this light curtain is reset in light received condition [open the test input / reset input → short-circuit the light curtain to +V for PNP output or 0 V for NPN output → open], the control outputs (OSSD 1 / OSSD 2) are turned ON. Emitter Emitter +24 V DC Interlock setting input (Pale purple) 17 Interlock setting input (Pale purple) 0V Test input / Reset input Beam received condition 20 ms or less Open Short-circuited Beam received Beam interrupted ON Control outputs (OSSD 1, OSSD 2) OFF T 90 ms or less T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) The reset switch shall be placed in area where all of the dangerous zone shall be comprehended and outside of the dangerous zone. Interlock disabled (automatic reset) • The control outputs (OSSD 1 / OSSD 2) are turned ON automatically when this light curtain receives light. Emitter Open Interlock setting input (Pale purple) In case that this light curtain is used under automatic reset mode, set the system not to be automatic reset by the safety relay unit, etc. (conforming to EN 60204-1) • It is also possible to change the interlock setting condition by the using the handy-controller SFC-HC. SF4C PRECAUTIONS FOR PROPER USE Test input function Safety input function • This function enables checking of the device operation by forcibly turning ON / OFF the control outputs (OSSD 1 / OSSD 2) of the receiver with the emitting light is received. • The selection of output ON / OFF is available by applying the test input / reset input wire (pink). Interlock function enabled (manual reset) Emitter Emitter Switch S1 +24 V DC Open: Control output ON 0 V: Control output OFF S1 Interlock setting input (Pale purple) Interlock setting input (Pale purple) Test input / Reset input (Pink) Test input / Reset input (Pink) • This function controls the control outputs (OSSD 1 / OSSD 2) of this light curtain by receiving detection signal of a safety contact or safety sensor which is connected to the safety input 1 wire (gray) and the safety input 2 wire (gray / black). • The control outputs (OSSD 1 / OSSD 2) forcibly turning OFF when safety input 1 / 2 is OFF. • A safety contact can be connected at the factory setting of this light curtain. • When connecting a safety sensor, the handy-controller SFC-HC is required. (Note) Furthermore, the number of safety sensor, which be able to connect this light curtain is 2. • Series connection is also available when connecting other SF4C series as a safety sensor to the safety input 1 wire (gray) and the safety input 2 wire (gray / black). • The safety contacts are available for an emergency stop switch with two N.C. (Normally Closed) contacts, etc., and the safety sensor is available for a light curtain or a safety switch with semiconductor output etc. Note: This setting is possible for SF4C series Ver.2.1 or later. S1 Switch S1 0V Open: Control output ON +V: Control output OFF Beam received condition at ON state Output operation Interlock function enabled (automatic reset) Emitter ON with non-operating status Safety (Emergency stop switch, etc.) Safety input 1: +V contact Guard closed ON Safety input 2: 0 V (Safety switch etc.) Emitter Switch S1 +24 V DC S1 Open Open: Control output OFF 0 V: Control output ON Interlock setting input (Pale purple) Interlock setting input (Pale purple) Wiring example for safety contact Open Test input / Reset input (Pink) Open: Control output OFF +V: Control output ON Control outputs (OSSD 1 / OSSD 2) 0 V DC Wiring example for safety sensor (light curtain etc.) Receiver 2 Receiver 2 Emitter 2 Safety sensor (Ex. SF4C) Emitter 2 Safety sensor (Ex. SF4C) +24 V DC +24 V DC Safety input 1 (Gray) Safety input 2 (Gray / Black) Safety input 1 (Gray) Safety input 2 (Gray / Black) Receiver 1 15 ms or less Short-circuited: Valid Open: Invalid 0 V (Blue) Test input / Open (OFF) Reset input Short-circuited (ON) • Safety input Safety input 2 (Gray / Black) 0V • When the test input is valid, the control outputs (OSSD 1 / OSSD 2) become OFF. • By using this function, malfunction due to extraneous noise or abnormality in the control outputs (OSSD 1 / OSSD 2) and the auxiliary output can be determined even from the equipment side. • In case of PNP output, normal operation is restored when the test input / reset input wire (pink) is connected to +V (for manual reset: open). • In case of NPN output, normal operation is restored when the test input / reset input wire (pink) is connected to 0 V (for manual reset: open). +24 V DC +V (Brown) Safety input 1 (Gray) S1 Switch S1 Open Light-ON (Light curtain etc.) Safety input 1, 2 Guard closed ON When using PNP output: +V When using NPN output: 0 V (Safety switch etc.) Safety sensor Emitter Test input / Reset input (Pink) Beam received condition at OFF state Control output 1 (Black) 0V Control output 1 (Black) Control output 2 (White) Control output 2 (White) Receiver 1 Emitter 1 Emitter 1 90 ms or less ON SF4C SF4C OFF Do not use the test input function for the purpose of stopping the machine in which this light curtain is installed. Failure to do so could result in death or serious injury. Safety input 2 (Gray / Black) Safety input 2 (Gray / Black) Safety input 1 (Gray) Safety input 1 (Gray) Control output 1 (Black) +V (Brown) Control output 2 (White) Control output 1 (Black) K1 0 V (Blue) K1 Control output 2 (White) K2 K2 • Safety input of this light curtain 0V Vs to Vs-3.5 V: ON Open: OFF • Safety input of this light curtain 0 to +2.5 V: ON Open: OFF Note: Vs is the applying supply voltage. 18 SF4C PRECAUTIONS FOR PROPER USE • Use 0.2 mm2 or more shielded cable when connecting other SF4C series cable to the safety input 1 / 2. • When extending the cable of other SF4C series which is connected to the safety input 1 / 2, use the exclusive cable and the total cable length should be 40.5 m 132.874 ft or less (for each emitter / receiver). If the total cable length is exceeding 40.5 m 132.874 ft, the device may malfunction, resulting in death or serious injury. • Response time of safety sensor is the sum of the response time of this light curtain and safety sensor itself. This light curtain Safety sensor Large multi-purpose indicator function • The selection of lights up / lights off is available by applying the large multi-purpose indicator input 1 (gray) or the large multi-purpose indicator input 2 (gray / black). Receiver Receiver Switch S1 +24 V DC S1 Large multi-purpose indicator input 1 (gray) Response time of this light curtain 9 ms (SF4C-F□) 7 ms (SF4C-H□) Response time of safety sensor In case of using SF4C-H□ as safety sensor. Response time of safety sensor + response time of this light curtain = 7 ms + 7 ms = 14 ms • Use a safety contact which incorporates two N.C. (Normally Closed) contacts and connect both the safety input 1 wire (gray) and the safety input 2 wire (gray / black). Take care that if only one wire is connected, the light curtain may not operate normally. • When using the light curtain in PNP output (or NPN output), use PNP output (or NPN output) safety sensor. The control outputs (OSSD 1 / OSSD 2) become OFF by using wrong output type of sensor. • Series connection is also available when connecting other SF4C series to the safety input 1 / 2. However, this light curtain does not incorporate the interference prevention function. Thus, take sufficient care when installing the light curtains. • Use a safety sensor which incorporates a crossover short-circuit function in the control output and connect both the safety input 1 wire (gray) and the safety input 2 wire (gray / black). Take care that if only one wire is connected, the device may not operate normally. • Make sure to connect to +V or 0 V when not using safety input function. For PNP output For NPN output Safety input Safety input Safety input 2 wire Safety input Safety input 2 wire function 1 wire (gray) (gray / black) 1 wire (gray) (gray / black) Safety contact Connected to +V Connected to 0 V Connected to +V Connected to 0 V input mode Safety senser Connected to +V Connected to +V Connected to 0 V Connected to 0 V input mode • It is possible to change the setting of input mode by using the handy controller SFC-HC. 19 0 V: Lights up in green Open: Lights off Large multi-purpose indicator input 2 (gray / black) Large multi-purpose indicator input 2 (gray / black) S2 S1 Switch S2 +V: Lights up in red Open: Lights off Control output 2 (OSSD 2) S2 Switch S2 0 V: Lights up in red Open: Lights off Large multi-purpose indicator input 1 (gray) Switch S1 Control output 1 (OSSD 1) +V: Lights up in green Open: Lights off 0 V DC • By wiring the large multi-purpose indicator input 1 (gray) and the large multi-purpose indicator input 2 (gray / black) to the auxiliary output wire (yellow-green / black) or the muting lamp output wire (red), the outputs operate simultaneously with the outputs. When used in conjunction with auxiliary output Receiver Emitter When used as muting lamps Receiver Emitter Auxiliary output (Yellow-green / Black) Muting lamp output (red) Large multi-purpose indicator input 1 (gray) or Large multi-purpose indicator input 2 (gray / black) Large multi-purpose indicator input 1 (gray) or Large multi-purpose indicator input 2 (gray / black) • Connected to auxiliary output Auxiliary output is ON: Lights up Auxiliary output is OFF: Lights off • Connected to muting lamp output Muting lamp output is ON: Lights up Muting lamp output is OFF: Lights off • It is also possible to change the large multi-purpose indicator operation setting (lights up, blinks, lights off) by using the handy-controller SFC-HC. SF4C PRECAUTIONS FOR PROPER USE Auxiliary output (Non-safety output) In case of setting the external device monitoring function to disabled • This light curtain incorporates the auxiliary output for the nonsafety output. The auxiliary output is incorporated in the emitter. Normal operation Auxiliary output setting Test input Negative logic of the control outputs (OSSD 1 / OSSD 2) ON Emitter Control outputs (OSSD 1 / OSSD 2) Lockout Light received Light interrupted OFF ON • Connect the external device monitoring input (yellowgreen) to the auxiliary output (yellow-green / black). At this time, set the auxiliary output as “negative logic of control outputs (OSSD 1, OSSD 2)” (factory setting). • The auxiliary output (yellow-green / black) cannot be connected to external devices. ON Receiver Emitter Emitter Auxiliary output (Yellow-green / Black) External device monitoring input (Yellow-green) +24 V DC Auxiliary output (Yellow-green / Black) +V (Brown) Auxiliary output Load (Yellow-green / Black) Load 0 V (Blue) • It is also possible to set the external device monitoring function to disabled by using the handy-controller SFC-HC. 0 V DC Note: When the external device monitoring function is set disabled, the auxiliary output cannot be used. For details, refer to “External device monitoring function” listed below. T Beam received Beam received condition Beam interrupted T Beam received Beam received condition Beam interrupted 90 ms or less ON Control outputs (OSSD 1, OSSD 2) OFF 90 ms or less External device monitoring input ON Control outputs (OSSD1, OSSD2) 300 ms or less ON OFF 300 ms or less T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) OFF 30 ms or less ON Auxiliary output (Negative logic of the OSSD) OFF 10 ms or less T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) Do not use the auxiliary output for the purpose of stopping the machine in which the SF4C series is installed. Failure to do so could result in death or serious injury. • The time set for external light curtain monitoring is 300 ms or less. Exceeding 300 ms turns the light curtain into lockout status. It can be set within 100 to 600 ms (in units of 10 ms) by using the handy-controller SFC-HC. T Beam received Beam received condition Beam interrupted • It is also possible to change the auxiliary output by using the handy-controller SFC-HC. ON Control outputs (OSSD 1, OSSD 2) OFF External device monitoring input External device monitoring function • This is the function for checking whether the external safety relay connected to the control outputs (OSSD 1, OSSD 2) perform normally in accordance with the control outputs (OSSD 1, OSSD 2) or not. Monitor the contact “b” of the external safety relay, and if any abnormality such as deposit of the contact, etc. is detected, change the status of the light curtain into lockout one, and turn OFF the control outputs (OSSD 1, OSSD 2). In case of setting the external device monitoring function to enabled 300 ms ON OFF Lockout status T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) Beam received Beam received condition Beam interrupted 90 ms or less ON Control outputs (OSSD 1, OSSD 2) OFF External device monitoring input ON OFF 300 ms Lockout status • Connect the external device monitoring input (yellow-green) to the external safety relay connected the control outputs (OSSD 1, OSSD 2). Receiver Receiver +24 V DC +24 V DC +V (Brown) +V (Brown) External device monitoring input (Yellow-green) K1 Control output 1 (Black) K2 Control output 2 (White) Control output 1 (Black) Control output 2 (White) K1 K2 K1 External device monitoring input (Yellow-green) K1 K2 K2 0 V (Blue) 0 V (Blue) 0V 0V 20 SF4C PRECAUTIONS FOR PROPER USE Muting function • Incorrect use of the muting control may cause accidents. Please understand the muting control fully, and use it. As for the muting control, the following international standards define the requirements. ISO 13849-1 (JIS B 9705-1) IEC 61496-1 (UL 61496 / JIS B 9704-1) IEC 60204-1 (JIS B 9960-1) IEC / TS 62046 EN 415-4 ANSI B11.19-1990 ANSI / RIA R15.06-1999 • Use the muting control while the machine cycle is not in danger mode. Maintain safety with the other measure while the muting control is activated. • For the application that the muting control is activated when a workpiece passes through the sensor, place the muting sensor so that the conditions for the muting control cannot be satisfied by intrusion of personnel when the workpiece is passing through the sensor or the workpiece is not passing through it. • The muting lamp should be installed in a position where it can always be seen by operators who set or adjust the machine. • Be sure to check the operation of the muting function before its use. Furthermore, check the state of the muting lamp (cleanliness or brightness etc.). • The muting function turns the safety function of this light curtain into disabled temporarily. When the control outputs (OSSD 1, OSSD 2) are ON, this function is available for passing the workpiece through the sensing area of the light curtain without stopping the machinery. Notes: 1) By using handy-controller SFC-HC, and connecting normally open (N.O.) type muting sensor to muting input A, and normally closed (N.C.) type muting sensor to muting input B, then muting function can be used for 0 to 3 sec. 2) Using handy-controller SFC-HC can configure muting lamp diagnosis function. If setting muting lamp diagnosis function to ineffective, muting function continues even when the lamp is out or not connected. 3) The muting time of this light curtain is unlimited by factory setting. Using the handy-controller SFC-HC, muting time can be set in 1 sec. unit from 1 to 600 sec. Specification for muting sensor Operation when Operation when sensor is ON sensor is OFF N.O. (Normally open) type ON with “Dark-ON” condition (photoelectric sensor, etc.) ON with “Normally open” condition (inductive proximity sensor, etc.) ON with object contacted condition (position switch, etc.) 0 V or +V Open • Be sure to use the muting sensor that satisfies the above table “Specification for muting sensor”. If the other muting sensor not satisfying the specification above, the muting function might become enabled with the timing that the machine designer cannot expect and could result in serious injury or death. • It is recommended that two muting lamps should be connected in parallel. However, take care not to exceed 6 W in total. Installation condition of muting sensor Muting sensor B Guard Light curtain Muting sensor C Muting sensor D Muting sensor A S (m/sec.) Muting function enabled Sensing object Receiver Receiver Guard Emitter Emitter 1 +24 V DC +24 V DC +V (Brown) 1 +V (Brown) 2 Safety zone Muting lamp output (Red) Muting lamp output (Red) Muting input 1 (Light blue / White) Muting input 1 (Light blue / White) Muting input 2 (Light blue / Black) Muting input 2 (Light blue / Black) 1 2 0V • The muting function becomes valid when all the conditions listed below are satisfied: 1 The control outputs (OSSD 1, OSSD 2) shall be ON. 2 The safety input 1 / 2 shall be ON. 3 Time difference between the time during muting input 1 / 2 becomes ON from OFF (open) and the time during muting input 1 / 2 becomes OFF (open) from ON should be between 0.03 to 3 sec. (Note 1) • The lamp to be connected to the muting lamp output shall be an incandescent lamp of 1.5 to 6 W. (When the muting lamp diagnosis function is enabled) (Note 2) • The following devices, photoelectric sensor with semiconductor output, inductive proximity sensor, position switch on N.O. (Normally open) contact, etc. are available for applying to the muting sensor. 21 3 3 Dangerous zone Shorten the distances between muting sensors A to C and between B to D than the whole length of the sensing object. The time of the sensing object to be passed through the muting sensors A to B shall be 0.03 to 3 sec. Distance between A and B (m) < S (m/sec.) × 3 (sec.) S: The moving speed (m/sec.) of the sensing object The time of the sensing object to be passed through the muting sensors C to D shall be under 3 sec. Distance between C and D (m) < S (m/sec.) × 3 (sec.) S: The moving speed (m/sec.) of the sensing object SF4C PRECAUTIONS FOR PROPER USE Muting sensor A Muting sensor B Muting sensor C Muting sensor D Emitter Emitter +24 V DC +V +V Test input / Reset input (Pink) +V (Brown) Override input (Yellow) To muting input 1 of light curtain To muting input 2 of light curtain Override input (Yellow) Muting sensor A 0V To muting input 1 of light curtain Muting sensor C 0V Muting sensor B 0V Muting sensor D 0V To muting input 2 of light curtain ON OFF Muting sensor B ON 30 ms to less than 3 sec. (Note 1) If one of the four conditions above becomes valid or timing exceeds 60 sec. (Note 2), the override function becomes valid. OFF Muting sensor C ON OFF Muting sensor D ON OFF Muting function ON OFF Beam received Beam received condition of Beam interrupted light curtain Control outputs (OSSD 1, OSSD 2) 0V • The override function becomes valid when all the conditions listed below are satisfied: 1 The safety input 1 / 2 shall be ON. 2 The signal shall be input to either muting input 1 or 2, or to both of the inputs. 3 The override input (yellow) shall be connected to +V (0 V when using NPN output), and the test input / reset input shall be opened (3 sec. continuously). 4 When the muting lamp diagnosis function is enabled, an incandescent lamp of 1.5 to 6 W shall be connected. (Factory setting is disabled) (Note 1) Muting sensor A 0 V (Blue) Test input / Reset input (Pink) 50 ms to 1 sec. (Note 2) T Notes: 1) Using handy-controller SFC-HC can configure muting lamp diagnosis function. If setting muting lamp diagnosis function to ineffective, muting function continues even when the lamp is out or not connected. 2) By using handy-controller SFC-HC, a change between 1 and 600 sec. by 1 sec. per unit is possible. 3) The override function operates only when the automatic reset is ON (the interlock is disabled). ON OFF • Make sure to operate the system for starting override function manually. Furthermore, the system shall be placed in area where all of the dangerous zone shall be comprehend and outside of the dangerous zone. • Using override function, make sure that there exist no operator in the dangerous zone, which may result in death or serious injury. T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) Notes: 1) By using handy-controller SFC-HC, and connecting normally open (N.O.) type muting sensor to muting input A, and normally closed (N.C.) type muting sensor to muting input B, then muting function can be used for 0 to 3 sec. This setting is possible for SF4C series Ver.2.1 or later. 2) If the muting lamp does not light up even if 1 sec. or more when the muting lamp diagnosis function is valid, the muting function becomes invalid. When the muting lamp diagnosis function is invalid, the muting function becomes valid 50 ms to 1 sec. after the input conditions of the muting sensor A (C) and B (D) were satisfied. • It is possible to set the muting function into disabled per beam channel respectively and to specify the input order of the muting inputs 1, 2 to be set into enabled by using the handy-controller SFC-HC. Within 1 sec. Test input / Reset input Open Short-circuited Open Override input Short-circuited Override function • This function sets the safety function of this light curtain enabled forcibly. When using the muting function, the override function can be used to start the machinery at times such as when the control outputs (OSSD 1 and OSSD 2) are OFF or when the muting sensors are ON when the line is to be started. ON Muting Sensor A / C OFF Muting Sensor B / D OFF ON Override function ON 3 to 4 sec. (Note 1) T Override input time: Max. 60 sec. (Note 2) OFF Sensing object Within the protection area ( ) Absent Present ON Control outputs (OSSD 1, OSSD 2) OFF 90 ms or less T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□) Notes: 1) This is when the muting lamp diagnosis function is valid. If the muting lamp does not light up even if 1 sec. or more is passed, the override function becomes invalid. When the muting lamp diagnosis function is invalid, the muting function becomes valid 3 sec. after the input conditions of the muting sensor A (C) and B (D) were satisfied. 2) By using handy-controller SFC-HC, a change between 1 and 600 sec. by 1 sec. per unit is possible. 22 SF4C PRECAUTIONS FOR PROPER USE Part description and function Indicator section of emitter Digital error indicator Top end Model information Incident light intensity indicator [STB] Fault indicator [FAULT] PNP indicator [PNP] A NPN indicator [NPN] B Test input indicator [TEST] C Beam-axis alignment indicator [RECEPTION] D Safety input 1 indicator [S1] Operation indicator [OSSD] Safety input 2 indicator [S2] A Beam-axis alignment indicator [RECEPTION] B C Large multi-purpose indicator D Note: SF4C-F15(-J05) does not incorporate the digital display. PNP indicator [PNP] A NPN indicator [NPN] B Test input indicator [TEST] C Beam-axis alignment indicator [RECEPTION] Safety input 2 indicator [S2] Digital error indicator Operation indicator [OSSD] Indicator section of receiver Digital error indicator Incident light intensity indicator [STB] Fault indicator [FAULT] PNP indicator [PNP] A NPN indicator [NPN] B Function setting indicator [FUNCTION] C Interlock indicator [INTERLOCK] D Sensing surface side Description Function When the large multi-purpose indicator input 1 is valid: lights up in red Large multi-purpose indicator When the large multi-purpose indicator input 2 is valid: (Red / Green) (Note 1) lights up in green When the large multi-purpose indicator input invalid: OFF When stable light is received: lights up in green Incident light intensity indicator When unstable light is received: lights up in orange (Orange / Green) [STB] When light is interrupted: OFF (Note 2) Beam-axis alignment indicator [RECEPTION] A B Muting input 1 indicator [MU1] Muting input 2 indicator [MU2] OSSD indicator [OSSD] Note: SF4C-F15(-J05) does not incorporate the digital display. Beam-axis alignment indicator (Red / Green) [RECEPTION] C Incident light intensity indicator [STB] Fault indicator [FAULT] PNP indicator [PNP] A NPN indicator [NPN] B Function setting indicator [FUNCTION] C Interlock indicator [INTERLOCK] D Muting input 1 indicator [MU1] Muting input 2 indicator [MU2] Digital error indicator Left side Right side Common to emitter and receiver D Safety input 1 indicator [S1] Bottom end Incident light intensity indicator [STB] Fault indicator [FAULT] Large multi-purpose indicator D Beam-axis alignment indicator [RECEPTION] Digital error indicator (Red) When light curtain top receives light: lights up in red When light curtain top end receives light: blinks in red When control outputs (OSSD 1 / OSSD 2) are ON: light up in green When light curtain upper middle receives light: lights up in red When control outputs (OSSD 1 / OSSD 2) are ON: lights up in green When light curtain lower middle receives light: lights up in red When control outputs (OSSD 1 / OSSD 2) are ON: lights up in green When light curtain bottom receives light: lights up in red When light curtain bottom end receives light: blinks in red When control outputs (OSSD 1 / OSSD 2) are ON: lights up in green When light curtain is lockout: lights up for incident error content Fault indicator (Yellow) [FAULT] When fault occurs in the light curtain: lights up or blinks OSSD indicator [OSSD] PNP indicator (Orange) [PNP] When PNP output is set: lights up NPN indicator (Orange) [NPN] When NPN output is set: lights up Emitter Description Operation indicator (Red / Green) [OSSD] (Note 3) Receiver Function Lights up while light curtain operation is as follows [sequential operation]: When control outputs (OSSD 1 / OSSD 2) are OFF: lights up in red When control outputs (OSSD 1 / OSSD 2) are ON: lights up in green Description OSSD indicator (Red / Green) [OSSD] Function setting indicator (Orange) [FUNCTION] Interlock indicator (Yellow) [INTERLOCK] Muting input 1 indicator (Orange) [MU1] Muting input 2 indicator (Orange) [MU2] Function When control outputs (OSSD 1 / OSSD 2) are OFF: lights up in red When control outputs (OSSD 1 / OSSD 2) are ON: lights up in green When handy-controller is connected: blinks When blanking function is enabled: lights up (Note 4) When interlock is enabled: lights up When interlock is disabled: OFF When muting input 1 is valid: lights up When muting input 1 is invalid: OFF When muting input 2 is valid: lights up When muting input 2 is invalid: OFF Test input indicator When test input is valid: lights up (Orange) [TEST] When test input is invalid: OFF Safety input 1 indicator When safety input 1 is valid: lights up (Orange) [S1] When safety input 1 is invalid: OFF Safety input 2 indicator When the safety input 2 is valid: lights up (Orange) [S2] When the safety input 2 is invalid: OFF Notes: 1) It is also possible to change the large multi-purpose indicator operation setting (lights up, blinks, lights off) by using the handy-controller SFC-HC. 2) The status when light is interrupted refers to the status that the some obstacle is existed in the sensing area. 3) Since the color of the operation indicator changes according to the ON / OFF status of the control outputs (OSSD 1, OSSD 2), the operation indicator is marked as “OSSD” on the light curtain. 4) The blanking function is set by using the handy-controller SFC-HC. 5) The description given in [ ] is marked on the light curtain. 23 SF4C PRECAUTIONS FOR PROPER USE • When this light curtain is used in the “PSDI mode”, an appropriate control circuit must be configured between this light curtain and the machinery. For details, be sure to refer to the standards or regulations applicable in each region or country. Safety distance • Calculate the safety distance correctly, and always maintain a distance which is equal to or greater than the safety distance, between the sensing area of this light curtain and the dangerous parts of the machinery. (Please check the latest standards for the equation.) If the safety distance is miscalculated or if sufficient distance is not maintained, there is a danger of serious injury or death. • Before designing the system, refer to the relevant standards of the region where this device is to be used and then install this device. • This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. • Both emitter and receiver are adjusted in combination at factory setting, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under model No.) • Make sure to carry out the test run before regular operation. • Do not install this light curtain with a machine whose operation cannot be stopped immediately in the middle of an operation cycle by an emergency stop equipment. Dangerous part of machine Emitter S Receiver Beam axis S: Safety distance Sensing area • Make sure to install this light curtain such that any part of the human body must pass through its sensing area in order to reach the dangerous parts of the machinery. If the human body is not detected, there is a danger of serious injury or death. • Do not use any reflective type or retroreflective type arrangement. • Furthermore, never use this light curtain facing several receivers towards one emitter or vice versa. Example of correct installation Dangerous part Sensing area Protective structure Dangerous part Sensing area Example of incorrect installation Dangerous part Sensing area Dangerous part The sizes of the minimum sensing objects for this light curtain vary depending on whether or not the floating blanking function is being used. Calculate the safety distance with the proper size of the minimum sensing object and appropriate equation. Size of minimum sensing object when applying floating blanking function Invalid Setting (Note 1) 1 beam channel 2 beam channels 3 beam channels SF4C-F□(-J05) ø14 mm ø24 mm ø34 mm (Min. sensing object ø14 mm) ø0.551 in ø0.945 in ø1.339 in SF4C-H□(-J05) ø25 mm ø45 mm ø65 mm (Min. sensing object ø25 mm) ø0.984 in ø1.772 in ø2.559 in Note: Refer to p.6 for details of the floating blanking function. ø44 mm ø1.732 in ø85 mm ø3.346 in • Safety distance is calculated based on the following equation when a person moves perpendicular (normal intrusion) to the sensing area of the light curtain. In case the intrusion direction is not perpendicular to the sensing area, be sure to refer to the relevant standard (regional standard, specification of the machine, etc.) for details of the calculation. (Please check the latest standards for the equation.) For use in Europe (EU) (as EN 999)] (Also applicable to ISO 13855 / JIS B 9715) For intrusion direction perpendicular to the sensing area Sensing area • Equation 1 S=K×T+C S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity of operator’s body or object (mm/sec.) Normally taken as 2,000 (mm/sec.) for calculation T: Response time of total equipment (sec.) T = Tm + TSF4C Tm: Maximum halting time of machinery (sec.) TSF4C: Response time of the SF4C series 0.007 (sec.) C: Additional distance calculated from the size of the minimum sensing object of the light curtain (mm) However, the value of “C” cannot be less than 0. C = 8 × (d – 14) d: Minimum sensing object diameter (mm) 24 SF4C PRECAUTIONS FOR PROPER USE • For calculating the safety distance “S”, there are the following five cases. First calculate by substituting the value K = 2,000 (mm/sec.) in the equation previous. Then, classify the obtained value of “S” into three cases, 1) S < 100, 2) 100 ≤ S ≤ 500, and 3) S > 500. For Case 3) S > 500, recalculate by substituting the value K = 1,600 (mm/sec.). After that, classify the calculation result into two cases, 4) S ≤ 500 and 5) S > 500. For details, refer to the instruction manual enclosed with this product. • When this light curtain is used in the “PSDI mode”, an appropriate safety distance “S” must be calculated. For details, be sure to refer to the standards or regulations applicable in each region or country. • Equation 1 S=K×T+C S: Safety distance (mm) K: Intrusion velocity of operator’s body or object (mm/sec.) Taken as 1,600 (mm/sec.) for calculation T: Response time of total equipment (sec.) T = Tm + TSF4C Tm: Maximum halting time of machinery (sec.) TSF4C: Response time of the SF4C series 0.007 (sec.) C: Additional distance calculated from the size of the minimum sensing object of the light curtain (mm) C = 850 (mm) (Constant) For use in the United States of America (as per ANSI/RIA 15.06) • Equation 2 S = K× (TS + TC + TSF4C + Tbm) + Dpf S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity {Recommended value in OSHA is 63 (inch/sec.) ≈ 1,600 (mm/sec.)} ANSI/RIA 15.06 does not define the intrusion velocity “K”. When determining “K”, consider possible factors including physical ability of operators. TS: Halting time calculated from the operation time of the control element (air valve, etc.) (sec.) TC: Maximum response time of the control circuit required for functioning the brake (sec.) TSF4C: Response time of light curtain (sec.) Tbm: Additional halting time tolerance for the brake monitor (sec.) The following equation holds when the machine is equipped with a brake monitor. Tbm = Ta – (Ts + Tc) Ta: Setting time of brake monitor (sec.) When the machine is not equipped with a brake monitor, it is recommended that 20 % or more of (Ts + Tc) is taken as additional halting time. Dpf: Additional distance calculated from the size of the minimum sensing of the Dpf = 61.2 mm 2.409 in (SF4C-H□), 23.8 mm 0.937 in (SF4C-F□) Dpf = 3.4 × (d – 0.276) (inch) ≈ 3.4 × (d – 7) (mm) d: Min. sensing object diameter 0.985 (inch) ≈ 25 (mm) (SF4C-H□) Min. sensing object diameter 0.552 (inch) ≈ 14 (mm) (SF4C-F□) • If the floating blanking function is used, min. sensing object become larger. When d > 64 mm 2.5 in, Dpf = 900 mm 3 ft as per ANSI/RIA 15.06 25 Output waveform [Control outputs (OSSD 1, OSSD 2) ON] • Since the receiver performs the self-diagnosis of the output circuit when the light curtain is in beam received condition (ON status), the output transistor becomes OFF status periodically. (Refer to the figure below.) When the OFF signal is fed back, the receiver judges the output circuit as normal. When the OFF signal is not fed back, the receiver judges either the output circuit or wiring as error, and the control outputs (OSSD 1, OSSD 2) maintain OFF status. Since the OFF signal of this light curtain might cause malfunction, perform the connection paying attention to the input response time of the machine to be connected to this light curtain. Beam Beam received received Beam condition interrupted 90 ms approx. or less 3.4 ms approx. (SF4C-F□) 2.5 ms approx. (SF4C-H□) Control output 1 ON (OSSD 1) OFF 35 to 75 μs approx. Control output 2 ON (OSSD 2) OFF 20 μs approx. 35 to 75 μs approx. 310 μs approx. 35 to 75 μs approx. 40 μs approx. 310 μs approx. 45 μs approx. 20 μs approx. 40 μs approx. 35 to 75 μs approx. * This OFF pulse appears in every 5 sec. cycle. Influence of reflective surfaces If there exists a reflective surface in the place where this light curtain to be installed, make sure to install this light curtain so that reflected light from the reflective surface does not enter into the receiver, or take countermeasures such as painting, masking, roughening, or changing the material of the reflective surface, etc. Failure to do so may cause the device not to detect, resulting in death or serious injury. • Install this light curtain at a distance of 0.16 m 0.525 ft or more from reflective surfaces such as metal walls, floors, ceilings, sensing objects, covers, panels or glass surfaces. Side view Top view Reflective surface Reflective ceiling Emitter 0.16 m 0.525 ft Receiver Emitter Operating range 0.1 to 3 m 0.328 to 9.843 ft 0.16 m 0.525 ft Reflective floor 0.16 m 0.525 ft Operating range 0.1 to 3 m 0.328 to 9.843 ft Receiver SF4C PRECAUTIONS FOR PROPER USE Handy-controller Others This light curtain enables to set each function using the handy-controller SFC-HC. Among the functions, the contents related to the safety distance such as the size of the minimum sensing object and response time are varied depending on the setting condition. When setting each function, re-calculate the safety distance, and make enough space larger than the calculated safety distance. Failure to do so might cause the accident that the device cannot stop quickly before reaching the dangerous area of the machinery, resulting in the serious injury or death. • Refer to the instruction manual enclosed with the handy-controller for details of the function settings for using handy-controller SFC-HC. Troubleshooting quick reference sheet Digital error indicator Possible cause Incorrect wiring. Affected by large noise. Handy-controller setting error. • Our products have been developed / produced for industrial use only. • Do not use during the initial transient time (2 sec.) after the power supply is switched on. • Avoid dust, dirt and steam. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Disclaimer • The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some intellectual properties, such as patent rights, with respect to such applications, or that the described application may not infringe any intellectual property rights, such as patent rights, of a third party. Incorrect number of beam channels of emitter and receiver. Interlock setting input wire (pale purple) or test input / reset input wire (pink) connected incorrectly. Affected by extraneous light, or mutual interference occurring. Safety input 1 (gray) or safety input 2 (gray / black) connected incorrectly. Control output 1 (black), control output 2 (white) connected incorrectly. Output polarity setting wires (shield) connected incorrectly. Output polarity setting wire is disconnected or short-circuited to other wire. External device (safety relay, etc.) is connected incorrectly or welding, out of the specified range. Auxiliary output wire (yellow-green / black) and external device monitoring input wire (yellow-green) are disconnected. Auxiliary output wire (yellow-green / black) is disconnected or short-circuited. Auxiliary output setting is changed by SFC-HC. Wiring, voltage or supply capacity is incorrected. Muting lamp output wire (red) connected incorrectly. Muting lamp is out of the specified range. Muting lamp output circuit malfunction. Control output 1 (black), control output 2 (white) connected incorrectly or flowing overcurrent. Emitter is in lockout status. Affected by noise. Internal circuit is broken down. Synchronization + wire (orange) or synchronization – wire (orange / black) connected incorrectly. Receiver or emitter malfunction. Receiver is in lockout status. [TEST] Test input / reset input wire (pink) is open when selecting automatic reset. Test input / reset input wire (pink) is connected to 0 V or +V when selecting manual reset. * Refer to the instruction manual for details. 26 SF4C DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. SF4C-F□ □ SF4C-H□ Light curtain Mounting bracket assembly dimensions Mounting drawing for the light curtains using the standard mounting brackets MS-SFC-1 (accessory). 30 1.181 10 0.394 30 13.2 0.520 1.181 t 2 t 0.079 10 0.394 7.7 (0.303 ) 5.4 0.213 ( ) 18 0.709 Display section (Note) Large Multi-purpose indicator 5.4 0.213 ( ) 13 0.512 21 0.827 30 1.181 7.7 (0.303 ) 12 0.472 Display section (Note) ( ) DCB A Large Multi-purpose indicator ( Beam pitch ) E AB ( 88 3.465 Large Multi-purpose indicator 13 0.512 Large Multi-purpose indicator ) Large Multi-purpose indicator ( 88 3.465 ) Receiver Model No. A B C 88 (3.465 ) Large Multi-purpose indicator E Large Multi-purpose indicator Beam pitch F 10 0.394 Emitter D 88 (3.465 ) E BA 10 0.394 Emitter 13 0.512 50.5 (1.988 ) F 16 10 0.630 0.394 13.2 0.520 t 2 t 0.079 12 0.472 Display section (Note) Large Multi-purpose indicator F 16 10 0.630 0.394 7.7 (0.303 ) 21 0.827 Beam pitch F 30 1.181 18 (0.709 ) 50.5 (1.988 ) 88 3.465 88 (3.465 ) 21 0.827 21 (0.827 ) 50.5 (1.988 ) 88 3.465 13.2 0.520 t 2 t 0.079 18 (0.709 ) 21 (0.827 ) 50.5 (1.988 ) 88 (3.465 ) 13.2 0.520 t 2 t 0.079 18 0.709 Display section (Note) 13 0.512 21 (0.827 ) DCB A 7.7 (0.303 ) Receiver SF4C-F15(-J05) SF4C-H8(-J05) 140 5.512 160 6.299 172 6.772 184 7.244 130 5.118 45 (1.772 ) SF4C-F23(-J05) SF4C-H12(-J05) 220 8.661 240 9.449 252 9.921 264 10.394 210 8.268 SF4C-F31(-J05) SF4C-H16(-J05) 300 11.811 320 12.598 332 13.071 344 13.543 290 11.417 ø15.6 ø0.614 SF4C-F39(-J05) SF4C-H20(-J05) 380 14.961 400 15.748 412 16.220 424 16.693 370 14.567 ø6 0 236 Digital error indicator SF4C-F47(-J05) SF4C-H24(-J05) 460 18.110 480 18.898 492 19.370 504 19.842 450 17.717 SF4C-F55(-J05) SF4C-H28(-J05) 540 21.260 560 22.047 572 22.520 584 22.992 530 20.866 Model No. F SF4C-F63(-J05) SF4C-H32(-J05) 620 24.409 640 25.197 652 25.669 664 26.142 610 24.016 SF4C-F□ 10 0.394 Note: Measurement of drawing above is display section of SF4C-H□. In case of SF4C-F□, the position of digital indicator (red) is different as right figure. Also, digital indicator (red) is not incorporated in SF4C-F15□. SF4C-H□ 20 0.787 MS-SFC-1 Standard mounting bracket (Accessory) 30 1.181 t2 t 0.079 10 0.394 MS-SFC-2 NA2-N compatible mounting bracket (Optional) t2 t 0.079 6 0.236 11.8 5.4 0.465 0.213 2-ø4.5 ø0.177 14.8 6.5 0.583 0.256 21 34 0.827 1.339 M3 countersunk screw mounting hole (for main body mounting) Material: Stainless steel (SUS304) Net weight: 32 g approx. (4 pcs.) Package weight: 35 g appox. Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached. 27 30 1.181 18 0.709 2 0.079 7.5 0.295 5 0.197 37 1.457 22.5 0.886 M3 countersunk screw mounting hole (for main body mounting) Material: Stainless steel (SUS304) Net weight: 36 g approx. (4 pcs.) Package weight: 40 g appox. Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached. SF4C DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. SF4C-F□ SF4C-H□ □ SF4C-H Light curtain Mounting bracket assembly dimensions Mounting drawing for the light curtains using the versatile brackets MS-SFC-C3 (optional) and intermediate supporting bracket for versatile brackets MS-SFC-F4 (optional). 7.5 ( 0.295 ) Display section (Note) 15 ( 0.591 ) 7.5 ( 0.295 ) MS-SFC-3 2 0.079 Display section 6.5 0.256 (Note) 15 ( 0.591 ) 2 0.079 6.5 0.256 MS-SFC-3 Display section (Note) Display section (Note) MS-SFC-3 MS-SFC-3 (22 0.866) Large Multi-purpose indicator Large Multi-purpose indicator Large Multi-purpose indicator MS-SFC-4 D A C 8 0.315 30 1.181 42 1.654 12.7 0.500 15 ( 0.591 ) 7.5 ( 0.295 ) 6.5 0.256 B 12.7 0.500 15 ( 0.591 ) 7.5 ( 0.295 ) 25.7 1.012 Emitter Inter mediate supporting bracket SF4C-F15(-J05) SF4C-H8(-J05) – SF4C-F23(-J05) SF4C-H12(-J05) – SF4C-F31(-J05) SF4C-H16(-J05) – SF4C-F39(-J05) SF4C-H20(-J05) – SF4C-F47(-J05) SF4C-H24(-J05) – SF4C-F55(-J05) SF4C-H28(-J05) ○ ○ SF4C-F63(-J05) SF4C-H32(-J05) 6.5 0.256 2 0.079 25.7 1.012 Receiver Model No. Large Multipurpose indicator A 8 0.315 21 0.827 MS-SFC-4 A’ 6.5 0.256 B 175 – 6.890 255 – 10.039 335 – 13.189 415 – 16.339 495 – 19.488 575 238 to 338 22.638 9.370 to 13.307 655 278 to 378 25.787 10.945 to 14.882 30 1.181 B’ (22 0.866) (22 0.866) 6.5 0.256 2 0.079 30 1.181 42 1.654 2 0.079 12.7 0.500 25.7 1.021 42 1.654 8 0.315 21 0.827 B’ 6.5 0.256 12.7 0.500 25.7 1.021 Emitter Receiver C D Model No. Inter mediate supporting bracket 190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378 160 6.299 240 9.449 320 12.598 400 15.748 480 18.898 560 22.047 640 25.197 SF4C-F15(-J05) SF4C-H8(-J05) – SF4C-F23(-J05) SF4C-H12(-J05) – SF4C-F31(-J05) SF4C-H16(-J05) – SF4C-F39(-J05) SF4C-H20(-J05) – SF4C-F47(-J05) SF4C-H24(-J05) – SF4C-F55(-J05) SF4C-H28(-J05) ○ ○ Notes: 1) Measurement of drawing above is display section of SF4C-H□ In case of SF4C-F□, the position of digital indicator (red) is different. Also, digital indicator (red) is not incorporated in SF4C-F15□. SF4C-F63(-J05) SF4C-H32(-J05) A' B' D 116 – 4.567 196 – 7.717 276 – 10.866 356 – 14.016 436 – 17.165 516 209 to 309 20.315 8.228 to 12.165 596 249 to 349 23.465 9.803 to 13.740 160 6.229 240 9.449 320 12.598 400 15.748 480 18.898 560 22.047 640 25.197 2) Be sure to mount MS-SFC-4 when using SF4C-F55(-J05)/F63(-J05)/ H28(-J05)/H32(-J05). MS-SFC-3 Versatile bracket (Optional) 14.5 0.571 2-ø4.5 ø0.177 Large Multi-purpose indicator D A’ 6.5 0.256 21 0.827 30 1.181 42 1.654 6.5 0.256 2 0.079 D MS-SFC-4 8 0.315 21 0.827 B Large Multipurpose indicator MS-SFC-4 D A C 6.5 0.256 Large Multi-purpose indicator (22 0.866) Large Multipurpose indicator 30 1.181 18 0.709 2 0.079 ( 6 0.236 5 0.197 6.5 0.256 Material: Stainless steel (SUS304) Net weight: 75 g approx. (4 pcs.) Package weight: 90 g appox. t1.5 t0.059 ) 13 (0.512 ) 3 (0.118 ) 14.5 0.571 7.5 0.295 22.5 37 0.886 1.457 M3 countersunk screw mounting hole (for main body mounting) M3 countersunk screw mounting hole (for main body mounting) (3 0.118) (3 0.118) (6 0.236) 21.5 0.846 (13 0.512) 7 0.276 6.5 0.256 23 0.906 5 0.197 t2 t0.079 2 0.079 18 0.709 30 1.181 2-ø4.5 ø0.177 t1.5 t0.059 t2 t0.079 Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached. 28 SF4C DIMENSIONS (Unit: mm in) MS-SFC-4 The CAD data in the dimensions can be downloaded from our website. Intermediate supporting bracket for versatile bracket (Optional) 43.5 1.713 27 1.063 (31 1.220) 27.3 1.075 ( 13.6 0.535 10.5 0.413 ) 9.7 0.382 t2 t0.079 8 0.315 6 0.236 6.5 0.256 6.5 0.256 27 1.063 37 1.457 Material: Stainless steel (SUS304) Net weight: 40 g approx. (2 pcs.) Package weight: 60 g appox. 10 0.394 20 25 0.787 0.984 3 ( 0.118 ) Two bracket set MS-SFCH-□ Metal protection case (Optional) Assembly dimensions Mounting drawing for the light curtains using the metal protection case (MS-SFCH-□). 18 0.709 ø6.4 ø0.252 (M6 mounting hole) (When using MS-SFC-2) 36.2 1.425 ø5.4 ø0.213 (M5 mounting hole) 19.6 0.772 (When using MS-SFC-1) ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1) 26 1.024 Display section 10 0.394 3 43.5 0.118 1.713 E 96 90 3.543 3.780 43.5 1.713 6 0.236 8 0.315 F 26 1.024 D C B A 5 0.197 5 0.197 D A 26 1.024 ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1) 19.6 0.772 ø6.4 ø0.252 (M6 mounting hole) (When using MS-SFC-2) 18 0.709 ø5.4 ø0.213 (M5 mounting hole) 4-ø4.8 ø0.189 (M4 mounting hole) (When using MS-SFC-2) (When using MS-SFC-1) 36.2 1.425 t2.3 t0.091 Model No. MS-SFCH-8 MS-SFCH-12 MS-SFCH-16 MS-SFCH-20 MS-SFCH-24 MS-SFCH-28 MS-SFCH-32 29 A B C D E F 190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378 180 7.087 260 10.236 340 13.386 420 16.535 500 19.685 580 22.835 660 25.984 175 6.890 255 10.039 335 13.189 415 16.339 495 19.488 575 22.638 655 25.787 172 6.772 252 9.921 332 13.071 412 16.220 492 19.370 572 22.520 652 25.669 162 6.378 242 9.528 322 12.677 402 15.827 482 18.976 562 22.126 642 25.276 26 1.024 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378 Net weight (2 pcs.) Model No. 160 g approx. MS-SFCH-8 240 g approx. MS-SFCH-12 340 g approx. MS-SFCH-16 420 g approx. MS-SFCH-20 520 g approx. MS-SFCH-24 600 g approx. MS-SFCH-28 700 g approx. MS-SFCH-32 A D 190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378 172 6.772 252 9.921 332 13.071 412 16.220 492 19.370 572 22.520 652 25.669 SF4C DIMENSIONS (Unit: mm in) SFB-CC□-MU The CAD data in the dimensions can be downloaded from our website. Mating cable with connector on one end (Optional) 45 (1.772 ) SFB-CCJ□-MU Mating cable with connectors on both ends (Optional) 45 (1.772 ) L 45 (1.772 ) L ø15.6 ø0.614 ø15.6 ø0.614 ø15.6 ø0.614 ø6 ø0.236 ø6 ø0.236 • Length L • Length L Model No. Model No. Length L Length L SFB-CC3-MU 3,000 118.110 SFB-CCJ3D-MU SFB-CC7-MU 7,000 275.590 SFB-CCJ3E-MU 10,000 393.700 SFB-CCJ10D-MU SFB-CC10-MU 3,000 118.110 SFB-CCJ10E-MU SFC-WY1 Y-shaped connector (Optional) WY1-CC3 WY1-CC10 66 2.598 22.5 0.886 13.5 0.531 42 (1.654 ) 41 1.614 Mating cable (Optional) L ø14 ø0.551 ø6 ø0.236 ø14 46.6 31 ø0.551 1.835 1.220 Model No. ø9 ø0.354 Length L WY1-CC3 3,000 118.110 WY1-CC10 SFC-HC Handy-controller (Optional) 65 2.559 25.4 1.000 10,000 393.700 SF-C13 Control unit (Optional) 30 1.181 6.75 0.266 4 0.157 23 0.906 10,000 393.700 35 1.378 67.3 2.650 ø6 ø0.236 cables, 0.5 m 1.640 ft long 130 5.118 5 0.197 6 0.236 34.5 1.358 3 × 5 = 15 3 × 0.197 = 0.591 91.6 3.606 FUNCTION 140 5.512 CANCEL ENTER 10 0.394 13.5 0.531 80 3.150 6.5 80.8 0.256 3.181 Suitable for 35 mm 1.378 in width DIN rail 5 0.197 13 0.512 22.5 0.886 30 Light curtain selection guide Do you require Type 4? YES NO Is the protective height 640 mm 25.197 in or YES less? NO SF2B Ver.2 NO 640 mm 25.197 in or more Type2 • Definition of terms Is the operating range 3 m 9.843 ft YES or less? 3 m 9.843 ft or more Protective height SF4C Min. sensing object SF4B Ver.2 Operating range Seamless structure for superior environmental resistance Seamless structure for superior environmental resistance Introduction to Panasonic Industrial Devices SUNX sensors that can be used as muting sensors Compact Photoelectric Sensor CX-400 SERIES • World standard size • 148 types for a wide variation Ultra-slim Photoelectric Sensor EX-10 SERIES U-shaped Micro Photoelectric Sensor PM-64 • 3.5 mm 0.138 in thickness • Long sensing range: 1 m 3.281 ft (thru-beam type: EX-19) SERIES • Extremely compact and space saving • A lineup of quick fitting-up connector type * The EX-20 series that is compatible with M3 mounting screws is also available. Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES • Industry longest in stable sensing range • 10 times the durability (Compared to previous models) • IP68g protective construction * Check the specifications for the muting sensors before making a selection. Refer to "PRECAUTIONS FOR PROPER USE" (P.21~) for details. Please contact .......... 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7211 Facsimile: +81-568-33-2631 Global Sales Department Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved © No. CE-SF4C-2-7 October, 2012 Specifications are subject to change without notice. 2012 PRINTED IN JAPAN
SFC-HC 价格&库存

很抱歉,暂时无法提供与“SFC-HC”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SFC-HC
  •  国内价格 香港价格
  • 1+3620.664811+450.55369
  • 10+3291.5329310+409.59668

库存:1