Type 4 PLe SIL3
Ultra-slim
LIGHT CURTAIN
SF4C SERIES
Conforming to Machine
& EMC Directive
Certified
Conforming to
OSHA / ANSI
Certified by
NRTL
Certified
[Excluding SF4C-F□
□(-J05)]
Machine safeguarding without sacrificing productivity
Ultra-slim Light Curtain
The picture is an image.
2012.10
panasonic.net/id/pidsx/global
Introducing a Type 4 light curtain that combines high end performance with
an ultra-slim enclosure.
The SF4C series has been designed to offer a machine safeguarding
solution without sacrificing productivity. Its size and shape allow for it to fit
efficiently into small machinery while maximizing the usable working space
for the equipment operator.
Slim
13 mm 0.512 in
Min. sensing object: ø14 mm (ø0.551 in) [Beam pitch 10 mm (0.394 in)]
ø25 mm (ø0.984 in) [Beam pitch 20 mm (0.787 in)]
Operating range: 0.1 to 3 m (0.328 to 9.843 ft)
Max.
640 mm
25.197 in
Min.
160 mm
6.299 in
Hand protection type
• Zero dead zone mounting is possible
• Close vertical mounting of two units is possible
13.2 mm 0.520 in
SF4C (with mounting bracket)
43 mm 1.693 in
Previous model (with mounting bracket)
* Usable work space is 60 mm 2.362 in wider than previous model.
1
Industry first*
* Based on research conducted by our company as of March 2009
Large built-in multi-purpose
indicators
Large LED bars on each side of the light curtain provide a wide visibility indicator
that can be customized for various applications be means of independent external
inputs. The indicator can be used as an operation indicator, job indicator, etc.
sensing object: ø14 mm ø0.551 in;
Finger protection type Minimum
Beam pitch: 10 mm 0.394 in
Tighter Beam Pitch
The finger type has a 10 mm 0.394 in beam pitch which allows
additional protection while reducing overall size.
Safety distance
Hand protection type
Finger protection type
102 mm 4.016 in
18 mm 0.709 in
Shortened by
84 mm 3.307 in
* Calculation based on ISO 13855 with 41 ms or longer being the machinery’s maximum stopping time.
* The light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855)
Simple Safety Distance Calculations
The response time of all finger protection light curtains in the
finger type is 9 ms or less. Recalculation of the safety distance
is unnecessary for each time light curtain length is changed.
102 mm 4.016 in
Shortened by
84 mm
3.307 in
Hand protection type
18 mm
0.709 in
100 mm
3.937 in min. *
Finger protection type
Characteristic
safety distance
for light curtain
Characteristic
safety distance for
the machinery's
maximum stopping time
*The light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855)
2
Smart equipment
Center mounting on
a □30 mm □1.181 in
aluminum frame
Large multi-purpose
indicator
88 mm
3.465 in
Previous model
Installation is
time-consuming
Wiring is
time-consuming
Front opening
is decreased
3
Machine safeguarding without sacrificing productivity
Slim size for efficient applications
Available work space is expanded from the previous model, and productivity is improved.
If the machine opening is 500 mm 19.685 in
Previous
SF4C series
Usable work space
Usable work space
83 %
(414 mm 16.299 in)
95 %
(474 mm 18.661 in approx.)
Usable work space
approx.
12
% UP
(60 mm 2.362 in)
43 mm 1.693 in
43 mm
(including mounting bracket) 1.693 in
13.2 mm 0.520 in
(including mounting bracket)
If the machine opening width is 500 mm 19.685 in
13.2 mm
0.520 in
If the machine opening width is 500 mm 19.685 in
Can be used in a variety of applications for simplified equipment [Large multi-purpose indicator]
The bright LED indicators located in the center of both
sides of each light curtain can be illuminated green or red
by using external inputs. There is no need for setting up a
separate indicator, so that equipment is consolidated.
Previous
SF4C series
Location is inconvenient and inefficient
Location is convenient and streamlined
Look at job indicator
Green
Red
Green
/ Red
Look at “large multi-purpose indicator”
Job indicator
(prepare separately)
External input device
Job indicator
(Lighting / blinking signal)
Power source
Power source
Light curtain
Light curtain
SF4C
Large multi-purpose
indicator
Input 1
Startup
switch
Startup
switch
Control circuit
Operator
Input 2
Control circuit
Operator
Applications
Use as an operation indicator
Use as an error indicator
Use as a muting lamp
Light curtain’s presence and operation
can be checked at a glance.
Confirm errors at a glance. Also,
details of the error condition can be
checked on the digital display.
●Solid green
●Blinking red
Equipment is
operating
There is no need to buy and install a
separate muting lamp.
Error present
Normal
Normal
Error
blinking
●Solid red
Emergency stop
Confirm detail of error
quickly on the digital display.
* SF4C-F□ differs in the position of digital display.
Use the handy-controller SFC-HC to change lighting conditions.
Refer to p.6 for details
* If a failure diagnosis of muting lamp is needed as
by the result of risk assessment, use the handycontroller SFC-HC to change the setting, and
connect the muting lamp output wire (red) of this
light curtain to an incandescent lamp separately.
Refer to p.6 for details
4
From designing and constructing equipment to exporting and maintenance
Beam-axis alignment indicators help to reduce startup time
The beam channels of the light curtain are displayed in four blocks so that incident light position is shown at a glance. When the
beam channel at the bottommost channel (or topmost channel), which is used as a reference for beam-axis alignments, is
correctly aligned, the LED blinks red. After this, each block lights red as the beam axes successively become aligned. When
all channel beam axes are aligned, all LEDs light green. The display also has a stability indicator (STB) added so that setup
can be carried out with greater stability.
A
B
C
D
1 block
OSSD
3 block
STB
2 block
Beam-axis
alignment
indicator
The bottommost channel
beam axis is aligned
4 block
Beam channels are
displayed in 4 blocks
Only the beam axes of the
two lower blocks are aligned
STB
STB
A
B
C
D
A
B
C
D
Blinking
OSSD
Light
up
OSSD
The bottommost LED ‘D’
is blinking red
The bottom two LEDs ‘C, D’
light up in red
All channel beam axes
are aligned
STB
Light
up
A
B
C
D
Light
up
OSSD
Light
up
All LEDs ‘A to D’
light up in green
Furthermore, STB display
allows the most stable incident
light status* to be confirmed.
A single model supports both PNP and NPN polarities reducing model numbers
PNP transistor output and NPN transistor output are combined in a single model. Overseas equipment that uses PNP,
replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations
where the control circuits for a single model are suitable for use worldwide.
■ Polarity can be changed easily by changing wiring
When the output polarity setting wire (shield) is
connected to 0 V, PNP output is selected, and when it
is connected to 24 V, it switches to NPN output.
PNP circuit
0V
Output polarity setting wire
(Shield)
NPN circuit 24 V
IP67 protection structure
An IP67 (IEC / JIS) rating is achieved with an ultra-slim
size for protection from environmental factors.
Lightweight!
The SF4C series is made of resin that is approx. 45 %
lighter than the conventional aluminum case type. Its
lightweight body eases the burden on the mounting
surface of the equipment and contributes to overall
reduced weight during equipment transportation or
overseas shipment.
*Except the cable part
PNP / NPN polarity indicator
Either PNP or NPN side lights
depending on which is selected.
Material suitable for manufacturing a
secondary battery
SF4C body is made of resin and the mounting bracket is
made of Stainless Steel (SUS), so materials used are
limited. Suitable for manufacturing secondary batteries
or for food production equipment.
Mounting bracket: SUS304
Mounting screw: SUSXM7 *
A fast response time for all models
SF4C-H□: 7 ms*, SF4C-F□: 9 ms*
The SF4C series reduces the safety distance as well as
the calculation work required for the safety distance
among models with different beam channels.
* When connecting safety sensors (light curtains, etc) to the safety input,
the response time will be the total time of connected units.
Mutual interference is reduced without
needing for interference prevention lines
The ELCA (Extraneous Light Check & Avoid) function
automatically shifts the scan timing in order to avoid
interference.
5
Body case: Polycarbonate alloy
* Effective from production in
November 2010.
Reducing the number of malfunctions
caused by extraneous light
Double scanning method and retry processing are
effective in eliminating the effects of extraneous light.
Machine safeguarding without sacrificing productivity
Handy-controller SFC-HC
enables the user to select
a variety of settings
SFC-HC
Operation of the large multi-purpose
indicators can be configured
Operation of large multi-purpose indicators (factory setting: mode 0)
Large
Large
Mode multi-purpose multi-purpose Control outputs
Muting
(OSSD 1 / OSSD 2) function
Override
function
indicator 1 indicator 2
OFF Enabled Enabled
High or Low High or Low ON
0
Solid red Solid green
1
Blinking red Blinking green
2
Solid red Blinking green
3
Blinking red Solid green
4 (Note 1) Solid red Blinking red
5 (Note 1) Blinking green Solid green
6 (Note 1)
Solid green Solid red Blinking green
7 (Note 1) Solid red Blinking red
Solid green Blinking green
Notes: 1) The blinking condition is prioritized over the solid
condition.
Notes: 2) During lockout, it is possible to blink red.
Lockout blinking function
When lockout occurs
Enabled
Blinking red
Disabled
Auxiliary output has selectable output configuration
Mode No.
Description
0
Negative logic of the control outputs (OSSD 1, OSSD 2) (factory setting)
1
Positive logic of the control outputs (OSSD 1, OSSD 2)
2
For test input enabled: output OFF, For Disabled: output ON
3
For test input enabled: output ON, For Disabled: output OFF
4
For unstable incident beam: OFF (Note 1)
5
For unstable incident beam: ON (Note 1)
6
For muting: ON
7
For muting: OFF
8
For beam received: ON, For beam interrupted: OFF (Note 2)
9
For beam received: OFF, For beam interrupted: ON (Note 2)
A
For safety input enabled: ON, Disabled: OFF
B
For safety input enabled: OFF, Disabled: ON
C
For lockout: OFF
D
For lockout: ON
Notes: 1) The output cannot be used while the fix blanking function,
floating blanking function or the muting function is activated.
2) This device outputs the beam received / interrupted state under
activating the auxiliary output switching function using the
handy-controller irrespective of activating other functions, fixed
blanking function, floating blanking function, and muting function.
Fixed blanking function which allows selective beam
channels to be activated improves productivity
Floating blanking function which allows non-specified
beam channels to be deactivated improves productivity
The SF4C series is equipped with a fixed blanking
function which allows specific beam channels to be
selectively interrupted without causing the control output
(OSSD) to output the OFF signal. This function is
convenient for use with applications in which certain
fixed obstacles tend to interrupt specific beam channels.
Furthermore, this function provides greater safety as the
control output (OSSD) will automatically output the OFF
signal if the fixed obstacles are subsequently removed
from the specific beam channels.
1, 2 or 3 non-specified beam channels can be
deactivated. If the number of beam channels that are
interrupted is less than or equal to the set number of
beam channels, then the control output (OSSD) will not
output the OFF signal. This function is useful in the event
when the positions of obstacles within the sensing area
must be changed during object rearrangement, or when
an object passes through the light curtain’s sensing area.
Note: When the floating blanking function is used, the size of the
min. sensing object is changed. Refer to “PRECAUTIONS
FOR PROPER USE” (p.24) for details.
A variety of other functions can be selected
Setting monitoring function
This function allows the user to confirm the details of
each light curtain setting. (Note)
Protection function
Unless the password is not input, any setting change
of the light curtain cannot be allowed. The factory
setting is set to invalid for the protecting function.
Copy function
Allows settings details to be copied into other light
curtains. In the event that the same setting must be
input into several different light curtains, this function will
reduce the time required for the input of settings. (Note)
Muting lamp diagnosis setting
When the muting lamp diagnosis is disabled, the muting
function will continue to operate even if the lamp is blown.
Note: This setting is possible for SF4C series Ver.2.0 or later.
6
Useful built-in muting control function improves productivity
Safety, productivity, and cost reduction [Muting control function]
Previous
Muting
lamps
Muting sensors
Safety circuit
(Safety relay, etc.)
Light curtain
SF4C series
The light curtain has a built-in muting
control function that causes the line to
stop only when a person passes
through the light curtain, and does not
stop the line when an object passes
through. The muting sensors and
muting lamps can be connected
directly to the light curtain.
Furthermore, the large multi-purpose
indicators can be used as muting
lamps, which contribute to less wiring
troubles, improvement of safety and
productivity, and cost reduction.
Muting unit
Muting
lamps
Muting sensors
Safety circuit
(Safety relay, etc.)
SF4C series
* If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the
handy-controller SFC-HC to change the setting, and connect the muting lamp output wire
(red) of this light curtain to an incandescent lamp separately.
Selective muting area [Separate muting control function for each beam channel]
The handy-controller SFC-HC can be
used to carry out muting control for
specified beam channels only.
Because individual beam channel can
be specified to suit the object, separate
guards to prevent entry do not need to
be set up.
While muting control is active (line operating)
HC
Line stopped
For example, depending on the height of the object, the muting function can be activated for 10 beam
channels starting from the bottom most, so that if the 11th or subsequent beam channels are
interrupted, it is judged that a person has entered the area and the line stops.
Safety measures when objects exit [Exit muting control function]
Muting at the exit of a machine is now
possible using the handy-controller
SFC-HC. Just set a Max. four sec.
delay timer on the muting sensors
located at the exit. This is efficient for
places with no installation space for
muting sensors and also reduces cost
and wiring.
HC
Entrance side
Exit side
Muting sensors are not needed on the exit side!
By installing muting sensors only within the dangerous zone and setting up a delay timer on
the sensor, muting control is made possible even on the exit side where muting sensors
cannot be installed.
7
Machine safeguarding without sacrificing productivity
Cost reduction in safety circuit without a safety relay unit
Safety circuit is constructed without the need for a safety relay unit [External device monitoring function]
Previous
The light curtain has a built-in external
device monitoring function (such as
deposited relay monitoring) and an
interlock function. This allows a safety
circuit to be constructed so that a
separate safety relay unit is not
needed, and the control box has
become smaller to help to achieve to
lower costs.
Light curtain
SF4C series
Monitoring
Reset input
Safety relay unit
Safety relays
Motor, etc.
Safety relays
Motor, etc.
Reset input
Monitoring
SF4C series
The light curtain can directly connect to external devices (safety relay, etc) without an
exclusive control unit. This allows for simplified equipment, cost reduction, and error
prevention.
Industry first*! Wire-saving when connecting to safety devices [Safety input function]
Contact outputs such as an emergency
stop switches or a safety door switches
can be connected to the light curtain.
Also, by using the handy-controller
SFC-HC up to three sets of light curtains
can be cascade connected for a
consolidated safety output.
* Based on research conducted by our company
as of March 2009
Direct connection of safety devices
SF4C series
Previous
Safety door switch,
emergency stop switch,
etc.
Monitoring
Light curtain
Safety door switch,
emergency stop switch,
etc.
2NC
Monitoring
2NC
Contactor
Safety relays
Safety relay unit
Contactor
Safety relays
Motor, etc.
A safety relay unit is needed for connecting safety devices other than
light curtain.
SF4C series
Motor, etc.
Direct connection of various safety devices is possible for a simplified
safety circuit.
By using the handy-controller SFC-HC up to three sets of light curtains can be cascade connected for a consolidated safety output. (Note)
2NC
Monitoring
Contactor
Monitoring
Safety relay unit
Motor, etc.
Two safety relays are needed
Light curtain for each set of light curtain
Three sets of light curtains require three sets of safety relays.
2NC
Safety door switch,
emergency stop switch,
etc.
Just two safety relays
are enough
Monitoring
Safety door switch,
emergency stop switch,
etc.
Individual monitoring by auxiliary output
Monitoring
HC
SF4C series
Previous
Contactor
Motor, etc.
Outputs of safety devices
are consolidated in one unit.
SF4C series
Individual monitoring on light curtains is possible while the outputs of
three sets of light curtains and other safety devices are consolidated
in one unit.
Note: This setting is possible with the use of handy-controller SFC-HC for SF4C series Ver.2.1 or later.
8
SF4C
PRODUCT CONFIGURATION
Maintenance is prioritized
Pigtailed type (Mounting bracket, connector attached cable)
Basic set in one model No.
Cable type [Mounting bracket, with 5 m (16.404 ft) cable]
Standard mounting bracket
MS-SFC-1 (Accessory)
Standard mounting bracket
MS-SFC-1 (Accessory)
1
2
4
3
Cable 5 m 16.404 ft (discrete wire)
Connector attached cable 0.5 m 1.640 ft
ORDER GUIDE
1 2 Light curtains
Finger protection type
Hand protection type
Appearance
Min. sensing object ø25 mm ø0.984 in Min. sensing object ø14 mm ø0.551 in
(10 mm 0.394 in beam pitch)
(20 mm 0.787 in beam pitch)
Type
Operating range
(Note 1)
1 Pigtailed type
SF4C-F15-J05
Beam
channel
No.
10 mm
0.394 in
Number of
beam
Protective height (mm in)
2 Cable type channels
15
160 mm 6.299 in
SF4C-F15
Model No. (Note 2)
SF4C-F23-J05
SF4C-F23
23
240 mm
SF4C-F31-J05
SF4C-F31
31
320 mm 12.598 in
SF4C-F39-J05
SF4C-F39
39
400 mm 15.748 in
SF4C-F47-J05
SF4C-F47
47
480 mm 18.898 in
SF4C-F55-J05
SF4C-F55
55
560 mm 22.047 in
SF4C-F63-J05
SF4C-F63
63
640 mm 25.197 in
SF4C-H8-J05
SF4C-H8
8
160 mm
6.299 in
SF4C-H12-J05
SF4C-H12
12
240 mm
9.449 in
SF4C-H16-J05
SF4C-H16
16
320 mm 12.598 in
SF4C-H20-J05
SF4C-H20
20
400 mm 15.748 in
SF4C-H24-J05
SF4C-H24
24
480 mm 18.898 in
SF4C-H28-J05
SF4C-H28
28
560 mm 22.047 in
SF4C-H32-J05
SF4C-H32
32
640 mm 25.197 in
9.449 in
Protective height
0.1 to 3 m
0.328 to 9.843 ft
Beam pitch 10 mm
10 mm
0.394 in
0.394 in
Beam
channel
No.
10 mm
0.394 in
Protective height
0.1 to 3 m
0.328 to 9.843 ft
Beam pitch 10 mm
20 mm
0.394 in
0.787 in
Notes: 1) The operating range is the possible setting distance between the
emitter and the receiver.
Receiver cannot be
placed in this range
Actual operating range
0.1 m of the light curtain
0.328 ft
Setting range of
the receiver
Emitter Receiver
3m
9.843 ft
2) The model No. with suffix “E” shown on the label affixed to the product is
the emitter, “D” shown on the label is the receiver.
(e.g.) Emitter of SF4C-H8-J05: SF4C-H8E-J05,
Receiver of SF4C-H8-J05: SF4C-H8D-J05
Receiver
3 4 Mating cables
Appearance
9
Model No.
SFB-CC3-MU
SFB-CC7-MU
SFB-CC10-MU
For receiver For emitter
3
With connectors
on both ends
4
Mating cables
With
connector
on one end
Type
SFB-CCJ3E-MU
Description
Length: 3 m 9.843 ft Cable with connector on one end for pigtailed type
Net weight: 430 g approx. (2 cables) Two cables per set for emitter and receiver
Length: 7 m 22.966 ft Cable color: Gray (for emitter),
Gray with black line (for receiver)
Net weight: 1,000 g approx. (2 cables)
Length: 10 m 32.808 ft Connector color: Gray (for emitter), Black (for receiver)
Net weight: 1,300 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in
Length: 3 m 9.843 ft
Net weight: 190 g approx. (1 cable)
10 m 32.808 ft Cable with connectors on both ends for pigtailed type
SFB-CCJ10E-MU Length:
Net weight: 660 g approx. (1 cable) Cable color: Gray (for emitter), Gray with black line (for receiver)
SFB-CCJ3D-MU
Connector color: Gray (for emitter), Black (for receiver)
Length: 3 m 9.843 ft
Net weight: 210 g approx. (1 cable) The min. bending radius: R6 mm R0.236 in
10 m 32.808 ft
SFB-CCJ10D-MU Length:
Net weight: 680 g approx. (1 cable)
SF4C
ORDER GUIDE
Spare parts (Accessories for light curtain)
Standard mounting bracket
Designation
Model No.
Description
•
Standard
mounting
bracket
MS-SFC-1
Allows the light curtain to be mounted at the rear with one M5
hexagon-socket-head bolt. Mounting direction of the bracket
can be selected between vertical or horizontal (no dead zone).
(4 pcs. per set for emitter and receiver)
Test rod ø14
SF4C-TR14
Min. sensing object for regular checking
(ø14 mm ø0.551 in)
Test rod ø25
SF4C-TR25
Min. sensing object for regular checking
(ø25 mm ø0.984 in)
MS-SFC-1
M5 hexagonsocket-head bolt
Purchase
separately.
Light
curtain
Four bracket set
Four M3 (length: 4 mm 0.157 in)
countersunk screws
Light curtain
Standard mounting bracket
MS-SFC-1 (Accessory)
M3 (length: 4 mm 0.157 in) countersunk screw
with loose-proof agent
OPTIONS
Mounting bracket
NA2-N compatible mounting bracket
Designation
NA2-N
compatible
mounting
bracket
Model No.
Description
MS-SFC-2
Used when changing over area sensor NA2-N series to the
SF4C series. The mounting holes of NA2-N series can continue
to be used. Center mounting by a M6 hexagon-socket-head
bolt is also possible.
(4 pcs. per set for emitter and receiver)
•
Versatile
bracket
MS-SFC-3
Two ways of mounting are possible.
1 Rear mounting which enables beam adjustment
2 Dead zoneless center mounting on aluminum frame
(4 pcs. per set for emitter and receiver)
Intermediate
supporting
bracket
for versatile
bracket
MS-SFC-4
Used to support the light curtain in the middle. Be sure to
purchase it when using MS-SFC-3 on SF4C-F55(-J05),
SF4C-F63(-J05), SF4C-H28(-J05) or SF4C-H32(-J05).
(2 pcs. per set for emitter and receiver)
Versatile bracket
MS-SFC-2
Mounting holes for M4 screw
Mounting hole for
M6 hexagon-sockethead bolt
M4 screw
Purchase
separately.
Light
curtain
Intermediate supporting bracket for versatile bracket
• MS-SFC-3
• MS-SFC-4
Mounting holes
for M4 screw
Mounting hole for
M6 hexagon-sockethead bolt
Mounting hole for
M6 hexagon-sockethead bolt
Mounting hole for
M6 hexagon-sockethead bolt
(Mount on either one)
Mounting holes
for M4 screw
10
SF4C
OPTIONS
Control unit
Designation
Appearance
Slim type
control unit
Model No.
SF-C13
Description
Use a discrete wire cable to connect to the light curtain.
Relay output.
Compatible with up to Control Category 4.
●Recommended safety relay
Safety relay
Panasonic Corporation
SF series
Item
Safety relay
SFS3-L-DC24V (AG1S132)
SFS4-L-DC24V (AG1S142)
DIN terminal block
SFS4-SFD (AG1S847)
Note: Contact Panasonic Corporation for details on the
recommended products.
Type
Model No.
Contact arrangement
Rated nominal
switching capacity
Min. switching capacity
Coil rating
Rated power
consumption
Operation time
Release time
Ambient temperature
Applicable standards
With LED indicator
SFS3-L-DC24V
SFS4-L-DC24V
3a1b
4a2b
6 A / 250 V AC, 6 A / 30 V DC
1 mA / 5 V DC
15 mA / 24 V DC
20.8 mA / 24 V DC
360 mW
500 mW
20 ms or less
20 ms or less
-40 to +85 °C -40 to +185 °F (Humidity: 5 to 85 % RH)
UL, C-UL, TÜV
Y-shaped connector
Type
Appearance
Wire-saving
Y-shaped
connector
Model No.
Description
SFC-WY1
Wire-saving connector for SF4C-F□-J05 and SF4C-H□-J05. Cables of
emitter and receiver are consolidated into one cable for wire-saving.
Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield),
large multi-purpose indicator input 1, and large multi-purpose indicator
input 2 only.
Power wire and synchronization wire are connected inside the connector.
Interlock is disabled (automatic reset).
WY1-CCN3
Cable with
connector
on one side
WY1-CCN10
Cable length: 3 m 9.843 ft
Net weight: 200 g approx.
(1 cable)
Mating cable for Y-shaped connector
Cable color: Gray (with black line)
Connector color: Black
Cable length: 10 m 32.808 ft
The min. bending radius: R6 mm R0.236 in
Net weight: 620 g approx.
(1 cable)
By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken
for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced.
Previous
A total of 24 wires
Only 7 wires
Less wiring mistakes! Reduced wiring time!
Easy wiring to Safety PLC, etc.
SF4C series
SF4C series
Safety PLC / Remote I/O
Safety relay unit SF-C13
CC-Link Safety system
remote I/O unit SF-CL1T264T
11
Y-shaped connector
Safety PLC / Remote I/O
Safety relay unit SF-C13
CC-Link Safety system
remote I/O unit SF-CL1T264T
SF4C
OPTIONS
Product configuration
Emitter Receiver
Extension cable
Extension cable (1 cable for receiver)
SFB-CCJ3D-MU (3 m 9.843 ft for receiver)
SFB-CCJ10D-MU (10 m 32.808 ft for receiver)
SFB-CCJ3D (3 m 9.843 ft)
SFB-CCJ10D (10 m 32.808 ft)
Pigtailed type
0.5 m 1.640 ft
Extension cable (1 cable for emitter)
SFB-CCJ3E-MU (3 m 9.843 ft for emitter)
SFB-CCJ10E-MU (10 m 32.808 ft for emitter)
Cable with connector on one side
(Common for all models)
Y-shaped connector
SFC-WY1
WY1-CCN3 (3 m 9.843 ft)
WY1-CCN10 (10 m 32.808 ft)
Connector pin layout
Connector
pin No.
Black connector
2
1
8
3
Receiver
7
Emitter
6
4
5
Gray connector
Description
1
OSSD 2
2
+24 V
3
OSSD 1
4
Not used
5
Large multi-purpose indicator input 1
6
Large multi-purpose indicator input 2
7
0V
8
Output polarity setting wire (Shield)
Wiring diagram of control unit SF-C13
• Connect the light curtain control outputs OSSD 1 and
OSSD 2 to S1 and S2 respectively.
• Connect the light curtain control outputs OSSD 1 and
OSSD 2 to S4 and S2 respectively and ground the + side.
Light curtain
(SF4C-F□-J05 and SF4C-H□-J05)
Light curtain
(SF4C-F□-J05 and SF4C-H□-J05)
Y-shaped connector
WY1-CCN□
+24 V DC
Not used (Yellow-green)
+24 V (Brown)
+24 V DC
Y-shaped connector
WY1-CCN□
Not used (Yellow-green)
+24 V (Brown)
Large multi-purpose indicator input 1 (Gray)
0V
(Blue)
Large multi-purpose indicator input 1 (Gray)
Large multi-purpose indicator input 2 (Gray / Black)
Output
polarity
setting wire
(Shield)
Large multi-purpose indicator input 2 (Gray / Black)
Output
polarity
setting wire 0 V
(Shield)
(Blue)
PLC, etc.
OSSD 2 (White)
OSSD 1 (Black)
OSSD 2 (White)
A1
S1
OSSD 1 (Black)
L1
RESET
(Note 1)
(Note 1) FUSE1
FUSE2
(Note 2)
S2 S3 S4 X1 X2 X3
13 23 33 41
S1
S2 S3 S4
X1
X2
F
K1
Ui
SF-C13 control circuit
A2
0V
INTER_LOCK
AUX
KA, KB: Force-guided relay
F.G.
or magnet contactor
33 41
K1
OUT
L1L2L3
34 42
KB
KB
KA
N
FUSE2
RESET
(Note 1)
(Note 2)
K2
FAULT
14 24
X3 13 23
SF-C13 control circuit
K2
OUT
L1
(Note 1) FUSE1
A1
F.G.
F
Ui
PLC, etc.
KA
M
3~
Notes: 1) The above diagram is when using manual reset. If automatic reset
is used, disconnect the lead from X2 and connect it to X3.
In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Unused wires must be insulated.
A2
0V
INTER_LOCK
FAULT
14 24 34 42
AUX
KA, KB: Force-guided relay
KB
or magnet contactor KA
N
L1L2L3
KB
KA
M
3~
Notes: 1) The above diagram is when using manual reset. If automatic reset
is used, disconnect the lead from X2 and connect it to X3.
In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Unused wires must be insulated.
12
SF4C
OPTIONS
Handy-controller
Appearance
Model No.
Pigtailed type
Mating cable
Handycontroller
Fix
ed
Floa bla
ting nki
Aux blan ng
Lig iliary king
ht
con emoutput
trol iss
ion
FU
NC
TIO
N
Control
circuit
Designation
SFC-HC
Co
de
Mo
Pr nitor
ote
Co ct
py
FUNCTION
CA
NC
EL
EN
CANCEL
TE
ENTER
R
Cable type
Handy-controller
Cable set
+V 0 V
Cable set for
cable type
connection
Synchronization –
Synchronization +
Not used
Control
circuit
SFC-WNC1
FUNCTION
CANCEL
Terminal
block
ENTER
Handy-controller
Metal protection case
Applicable
beam channels
Designation
Metal protection case
(2 pcs. per set for emitter and receiver)
SF4C-H□
SF4C-F□
8
15
MS-SFCH-8
12
23
MS-SFCH-12
16
31
MS-SFCH-16
20
39
MS-SFCH-20
24
47
MS-SFCH-24
28
55
MS-SFCH-28
32
63
MS-SFCH-32
• MS-SFCH-□
• MS-SFCH-8
Model No.
SPECIFICATIONS
Light curtain individual specifications
Item
Model No.
SF4C-F□
Type
Pigtailed type SF4C-F15-J05
Cable type
SF4C-F15
Current consumption
No. of beam channels
Protective height
Large multi- purpose
indicator lights off
Large multi- purpose
indicator lights up
PFHD
MTTFd
Net weight Pigtailed
Total of
type
emitter and
Cable type
receiver
( )
Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch)
SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05 SF4C-F47-J05 SF4C-F55-J05
SF4C-F23
SF4C-F31
SF4C-F39
SF4C-F47
SF4C-F55
SF4C-F63-J05
SF4C-F63
15
23
31
39
47
55
63
160 mm 6.299 in 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in
Emitter: 70 mA or less
Emitter: 75 mA or less
Emitter: 80 mA or less
Emitter: 85 mA or less
Receiver: 80 mA or less
Receiver: 85 mA or less
Receiver: 90 mA or less
Receiver: 95 mA or less
Emitter: 105 mA or less
Emitter: 110 mA or less
Emitter: 115 mA or less
Emitter: 120 mA or less
Receiver: 110 mA or less
Receiver: 115 mA or less
Receiver: 120 mA or less
Receiver: 125 mA or less
2.29 × 10–9
2.73 × 10–9
3.18 × 10–9
3.62 × 10–9
4.06 × 10–9
4.50 × 10–9
4.95 × 10–9
100 years or more
210 g approx.
270 g approx.
340 g approx.
400 g approx.
470 g approx.
540 g approx.
600 g approx.
600 g approx.
670 g approx.
730 g approx.
800 g approx.
860 g approx.
930 g approx.
1,000 g approx.
Item
Model No.
SF4C-H□
Type
Pigtailed type
Cable type
Current consumption
No. of beam channels
Protective height
Large multi- purpose
indicator lights off
Large multi- purpose
indicator lights up
PFHd
MTTFD
Net weight Pigtailed
Total of
type
emitter and
Cable type
receiver
( )
13
SF4C-H8-J05
SF4C-H8
Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch)
SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05 SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05
SF4C-H12
SF4C-H16
SF4C-H20
SF4C-H24
SF4C-H28
SF4C-H32
8
12
16
20
24
28
32
160 mm 6.299 in 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in
Emitter: 70 mA or less
Emitter: 70 mA or less
Emitter: 75 mA or less
Emitter: 80 mA or less
Receiver: 85 mA or less
Receiver: 90 mA or less
Receiver: 95 mA or less
Receiver: 100 mA or less
Emitter: 120 mA or less
Emitter: 120 mA or less
Emitter: 120 mA or less
Emitter: 120 mA or less
Receiver: 135 mA or less
Receiver: 140 mA or less
Receiver: 145 mA or less
Receiver: 150 mA or less
1.66 × 10–9
1.90 × 10–9
2.10 × 10–9
2.33 × 10–9
2.54 × 10–9
2.77 × 10–9
2.98 × 10–9
100 years or more
240 g approx.
300 g approx.
360 g approx.
420 g approx.
490 g approx.
550 g approx.
610 g approx.
630 g approx.
700 g approx.
760 g approx.
820 g approx.
880 g approx.
950 g approx.
1,000 g approx.
SF4C
SPECIFICATIONS
Light curtain common specifications
Type
Applicable standards
Item
Model No.
International standard
Pigtailed type
SF4C-F□-J05
North America (Note 3)
Min. sensing object (Note 5)
Effective aperture angle
Supply voltage
Control outputs
(OSSD 1, OSSD 2)
Operation mode
Protection circuit
Response time
Auxiliary output
(Non-safety output)
Operation mode
Protection circuit
ELCA function
Test / reset input function
Interlock function
External device monitoring function
Safety input function
Muting function
Override function
Environmental resistance
Optional functions (Note 9)
SF4C-F□
SF4C-H□
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PL e), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
Operating range (Note 4)
Beam pitch
SF4C-H□-J05
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
Japan
Europe (EU) (Note 2)
Cable type
0.1 to 3 m 0.328 to 9.843 ft
10 mm 0.394 in
20 mm 0.787 in
10 mm 0.394 in
20 mm 0.787 in
ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object
±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC +10
–15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
• Max. source current: 200 mA
• Max. sink current: 200 mA
• Applied voltage: same as supply voltage
• Applied voltage: same as supply voltage
(between the control output and +V)
(between the control output and 0 V)
• Residual voltage: 2.5 V or less (source current 200 mA,
• Residual voltage: 2.5 V or less (sink current 200 mA, when
when using 10 m 32.808 ft length cable)
using 10 m 32.808 ft length cable)
• Leakage current: 200 μA or less (including power supply OFF condition) • Leakage current: 200 μA or less (including power supply OFF condition)
• Max. load capacity: 1 μF (No load to Max. output current)
• Max. load capacity: 1 μF (No load to Max. output current)
• Load wiring resistance: 3 Ω or less
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal)(Note 6,7)
Incorporated
OFF response: 9 ms or less, ON response: 90 ms or less OFF response: 7 ms or less, ON response: 90 ms or less OFF response: 9 ms or less, ON response: 90 ms or less OFF response: 7 ms or less, ON response: 90 ms or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
• Max. source current: 100 mA
• Max. sink current: 100 mA
• Applied voltage: same as supply voltage
• Applied voltage: same as supply voltage
(between the auxiliary output and +V)
(between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less
• Residual voltage: 2.5 V or less
(source current 100 mA, when using 10 m 32.808 ft length cable)
(sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the handy-controller SFC-HC).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note 8)]
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change,
interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
Degree of protection
IP67 / IP65 (IEC)
Ambient temperature
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –13 to +140 °F
Ambient humidity
Ambient illuminance
Dielectric strength voltage
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 ℓx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
Emitting element
Material
Cable
Cable extension
Accessories
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy
0.15 mm2 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
0.15 mm2 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note 10)
MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set,
SF4C-TR14 (Test rod): 1 No.
SF4C-TR25 (Test rod): 1 No.
SF4C-TR14 (Test rod): 1 No.
SF4C-TR25 (Test rod): 1 No.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
3) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL)
certified by OSHA, has certified with the safety certificate based on UL / ANSI standards.
With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD, a Certification Body
accredited by SCC, has certified with the safety certificate based on CSA standards.
4) The operating range is the possible setting distance between the emitter and the receiver. The light curtain can detect an object less than 0.1 m 0.328 ft away.
5) When the floating blanking function is used, the size of the min. sensing object is changed. For details, refer to “Safety distance” (p.24~).
6) The outputs are not “OFF” when muting function is active even if the beam channel is interruped.
7) In case the blanking function is valid, the operation mode is changed. For details, refer to “Safety distance” (p.24~).
8) The manual reset and automatic reset are possible to be switched depending on the wiring status.
9) In case of using optional function, the handy-controller SFC-HC is required.
10) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
14
SF4C
SPECIFICATIONS
Control unit
Item
Model No.
Connectable light curtains
Applicable standards
Control category
SF-C13
Light curtain manufactured by Panasonic Industrial Devices SUNX
IEC 61496-1, UL 61496-1, JIS B 9704-1
ISO 13849-1 (JIS B 9705-1) compliance up to Category 4, PL e standards
Supply voltage / Current consumption
24 V DC ± 10 % Ripple P-P 10 % or less / 100 mA or less (without light curtain)
Fuse (power supply)
Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling path
NO contact × 3 (13-14, 23-24, 33-34)
Application category
Rated operation voltage (Ue) /
Rated operation current (le)
Contact resistance
Contact protection fuse rated
Pick-up delay (Auto reset / Manual reset)
Response time (Recovery time)
Auxiliary output
AC-15, DC-13 (IEC 60947-5-1)
30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection).
Min applicable load: 10 mA (at 24 V DC) (Note 2)
100 mΩ or less (initial value)
4 A (slow blow)
80 ms or less / 90 ms or less
10 ms or less
Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Rated operation voltage / current
Contact protection fuse rated
Semiconductor auxiliary
output (AUX)
Output operation
Excess voltage category
Polarity selection function
Pollution degree
24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
2 A (slow blow)
PNP open-collector transistor
• Max. source current: 60 mA
On when the light curtain is interrupted
II
Incorporated (Cable connection allows selection of plus / minus ground)
Minus ground: Correspond to PNP output light curtain
Plus ground: Correspond to NPN output light curtain
2
Protection
Enclosure: IP40, Terminal IP20
Ambient temperature
Enclosure material
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
ABS
Net weight: 200 g approx.
Notes: 1) Where measurement conditions have not been specifed precisely, the conditions used were an ambient
temperature of +20 °C +68 °F
2) If several SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more between
each unit. If the units are touching each other, reduce the rated operating current for safety output in
accordance with the ambient operating temperature as shown in the graphs at right.
3) Refer to our website for details of specifications.
Dilating when SF-C13 units
are mounted close together
6
Rated operation current (A)
Weight
5
4
3
2
1
0
32
35 40 45 50 55
95 104 113 122 131
Ambient temperature (°C °F)
Handy-controller
Model No.
Item
Supply voltage
Current consumption
Communication method
Digital display
Function indicators
Functions
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
SFC-HC
24 V DC +10
–15 % Ripple P-P 10 % or less (common to light curtain power supply)
65 mA or less
RS-485 two-way communications (Specific procedure)
4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.)
Green LED × 9 (Set function is displayed.)
Fixed blanking / Floating blanking / Auxiliary output change / Satety input setting change / Large multi-purpose indicator
setting change / Muting setting change / Interlock setting change / External device monitoring setting change / Override setting
changing function 60 sec. / Protecting
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
30 to 85 % RH, Storage: 30 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Cable
12-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables)
Weight
Net weight: 200 g approx.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
15
SF4C
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
I/O circuit diagram
Terminal No. of pigtailed type
Color code
Emitter
Terminal No. of pigtailed type
Color code
Emitter
(Brown) +V
(Brown) +V
(Pink) Test input /
470 Ω Reset input
6.8 kΩ
6.8 kΩ
6.8 kΩ
6.8 kΩ
(Red) Muting lamp output
6.8 kΩ
470 Ω (Yellow) Override input *S2
6.8 kΩ
Sensor circuit
3 kΩ
+
–
(Gray) Safety input 1
24 V DC
%
+10
–15
6.8 kΩ
(Shield) Output polarity setting wire
Internal circuit
Receiver
47 kΩ
6.8 kΩ
Sensor circuit
6.8 kΩ
(Pink) Test input / Reset input
6.8 kΩ
6.8 kΩ
470 Ω
0.47 μF
Load
(Orange) Synchronization +
(Orange / Black) Synchronization –
(Orange / Black) Synchronization –
Users’ circuit
Internal circuit
Receiver
*S2
*S2
Users’ circuit
(Orange / Black)
Synchronization –
(Orange) Synchronization +
(Orange) Synchronization +
(Brown) +V
(Brown) +V
(Gray) Large multi*S2
purpose indicator input 1
(Shield) Output polarity setting wire
K1
(Black) Control output 1 (OSSD 1)
470 Ω
(Light blue / White) *S2
Muting input 1
470 Ω
(Light blue / Black) *S2
Muting input 2
470 Ω
(Yellow-green)
External device monitoring input
K2
K1
(White) Control output 2 (OSSD 2)
K2
6.8 kΩ
6.8 kΩ 470 Ω (Yellow-green) External device monitoring input
0.47 μF
6.8 kΩ
47 kΩ
0.1 μF
(Black) Control output 1 (OSSD 1)
47 kΩ
0.1 μF
(White) Control output 2 (OSSD 2)
47 kΩ
6.8 kΩ
0.1 μF
K1
(Shield)
Output polarity setting wire
*S1
6.8 kΩ
(Blue) 0 V
470 Ω
(Gray) Large multi470 Ω purpose indicator input 1
*S2
47 kΩ
(Gray / Black) Large multi- *S2
470 Ω purpose indicator input 2
K1
(Light blue / White)
470 Ω Muting input 1
*S2
6.8 kΩ (Light blue / Black)
470 Ω Muting input 2
*S2
K2
K2
6.8 kΩ
(Blue) 0 V
(Blue) 0 V
0.1 μF
6.8 kΩ
K1, K2: Force-guided relay or magnet contactor
Internal circuit
(Yellow) Override input
(Orange) Synchronization +
(Gray / Black) Large multi- *S2
purpose indicator input 2
6.8 kΩ
0.47 μF
470 Ω
(Blue) 0 V
Sensor circuit
47 kΩ
47 kΩ 470 Ω
0.1 μF
(Gray / Black) Safety input 2
24 V DC
%
+10
–15
6.8 kΩ
6.8 kΩ
(Orange / Black)
Synchronization –
47 kΩ
0.1 μF
3 kΩ
6.8 kΩ (Pale purple)
470 Ω Interlock setting input
0.47 μF
0.1 μF
(Gray) Safety input 1
6.8 kΩ
0.47 μF
(Gray / Black) Safety input 2
(Yellow-green / Black)
Auxiliary output
+
–
3 kΩ
(Red) Muting lamp output
3 kΩ
0.1 μF
Load
(Yellow-green / Black) Auxiliary output
(Pale purple)
470 Ω Interlock setting input *S2
0.47 μF
0.47 μF
*S1
Sensor circuit
0.47 μF
(Shield) Output polarity setting wire
Internal circuit
Users’ circuit
* S1, S2
K1, K2: Force-guided relay or magnet contactor
Users’ circuit
* S1, S2
Switch S1
• Test input / Reset input
For manual reset
Vs to Vs – 3.5 V (sink current 5 mA or less): OFF (Note)
Open: ON
Switch S1
• Test input / Reset input
For manual reset
0 to +2.5 V (source current 5 mA or less): OFF
Open: ON
For automatic reset
Vs to Vs – 3.5 V (sink current 5 mA or less): ON (Note)
Open: OFF
For automatic reset
0 to +2.5 V (source current 5 mA or less): OFF
Open: ON
Switch S2
• Interlock setting input, Override input, Muting input 1 / 2,
Large multi-purpose indicator input 1 / 2,
Vs to Vs – 3.5 V (sink current 5 mA or less): Valid (Note)
Open: Invalid
Switch S2
• Interlock setting input, Override input, Muting input 1 / 2,
Large multi-purpose indicator input 1 / 2,
0 to +2.5 V (source current 5 mA or less): Valid
Open: Invalid
Note: Vs is the applying supply voltage.
16
SF4C
I/O CIRCUIT AND WIRING DIAGRAMS
Connection example
Basic wiring: Min. operation only
This is the general configuration using one set of the emitter and receiver facing each other. The control outputs (OSSD 1 / OSSD 2) turn OFF
if the light is interrupted, while they automatically turn ON if receive the light.
The auxiliary output is used to invalid the external device monitoring function. The auxiliary output cannot be connected to external devices.
Receiver
(Red) Muting lamp output (p.21~)
Open
(Yellow) Override input (p.22)
Open
(Pale purple) Interlock setting input (p.17~) Open
(Brown) +V
(Pink) Test input / Reset input (p.18)
(Gray) Safety input 1 (p.18~)
+
(Gray / Black) Safety input 2 (p.18~)
–
(Shield) Output polarity setting wire
(Blue) 0 V
(Yellow-green / Black) Auxiliary output (p.20)
(Orange) Synchronization +
(Orange / Black) Synchronization –
(Orange / Black) Synchronization –
(Orange) Synchronization +
(Yellow-green) External device monitoring input (p.20)
(Brown) +V
(Black) Control output 1 (OSSD 1) K1
(White) Control output 2 (OSSD 2)
K2
(Shield) Output polarity setting wire
(Blue) 0 V
(Light blue / White) Muting input 1 (p.21~)
Open
(Light blue / Black) Muting input 2 (p.21~)
Open
(Gray) Large multi-purpose indicator input 1 (p.19)
Open
(Gray / Black) Large multi-purpose indicator input 2 (p.19) Open
Emitter
Gray cable
Gray cable
(with black line)
Receiver
Emitter
24 V DC
%
+10
–15
Gray cable
Gray cable
(with black line)
24 V DC
%
+10
–15
K1, K2: Force-guided relay or magnet contactor
K1, K2: Force-guided relay or magnet contactor
Interlock function
External device monitoring
function
Auxiliary output
Output polarity setting wire
Safety input
(Red) Muting lamp output (p.21~)
Open
(Yellow) Override input (p.22)
Open
(Pale purple) Interlock setting input (p.17~)
Open
(Brown) +V
(Shield) Output polarity setting wire
(Gray) Safety input 1 (p.18~)
+
(Gray / Black) Safety input 2 (p.18~)
–
(Pink) Test input / Reset input (p.18)
(Blue) 0 V
(Yellow-green / Black) Auxiliary output (p.20)
(Orange) Synchronization +
(Orange / Black) Synchronization –
(Orange / Black) Synchronization –
(Orange) Synchronization +
(Yellow-green) External device monitoring input (p.20)
(Brown) +V
(Black) Control output 1 (OSSD 1) K1
(White) Control output 2 (OSSD 2)
K2
(Shield) Output polarity setting wire
(Blue) 0 V
(Light blue / White) Muting input 1 (p.21~)
Open
(Light blue / Black) Muting input 2 (p.21~)
Open
(Gray) Large multi-purpose indicator input 1 (p.19)
Open
(Gray / Black) Large multi-purpose indicator input 2 (p.19) Open
Disabled (Automatic reset)
Interlock function
External device monitoring
function
Auxiliary output
Output polarity setting wire
Safety input
Disabled
Not used
PNP
Invalid
Disabled (Automatic reset)
Disabled
Not used
NPN
Invalid
PRECAUTIONS FOR PROPER USE
Interlock function
• You can select whether interlock is enabled (manual
reset) or disabled (automatic reset) by the way in which
the interlock setting input wire (pale purple) is connected.
Interlock function
Reset operation Interlock setting input (pale purple)
Enabled
Manual reset
When selecting PNP output: Connected to +V
When selecting NPN output: Connected to 0 V
Disabled
Automatic reset
Open
Make sure that there exist no operator in the
dangerous zone when using the interlock function,
which can result in death or serious injury.
Interlock enabled (manual reset)
• The control outputs (OSSD 1 / OSSD 2) are not turned ON automatically
even though this light curtain is receiving the light.
When this light curtain is reset in light received condition [open the test input
/ reset input → short-circuit the light curtain to +V for PNP output or 0 V for
NPN output → open], the control outputs (OSSD 1 / OSSD 2) are turned ON.
Emitter
Emitter
+24 V DC
Interlock setting input
(Pale purple)
17
Interlock setting input
(Pale purple)
0V
Test input /
Reset input
Beam received
condition
20 ms or less
Open
Short-circuited
Beam received
Beam interrupted
ON
Control outputs
(OSSD 1, OSSD 2) OFF
T
90 ms or less
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
The reset switch shall be placed in area where all
of the dangerous zone shall be comprehended
and outside of the dangerous zone.
Interlock disabled (automatic reset)
• The control outputs
(OSSD 1 / OSSD 2) are
turned ON automatically
when this light curtain
receives light.
Emitter
Open
Interlock setting input
(Pale purple)
In case that this light curtain is used under
automatic reset mode, set the system not to
be automatic reset by the safety relay unit, etc.
(conforming to EN 60204-1)
• It is also possible to change the interlock setting
condition by the using the handy-controller SFC-HC.
SF4C
PRECAUTIONS FOR PROPER USE
Test input function
Safety input function
• This function enables checking of the device operation
by forcibly turning ON / OFF the control outputs (OSSD
1 / OSSD 2) of the receiver with the emitting light is
received.
• The selection of output ON / OFF is available by applying
the test input / reset input wire (pink).
Interlock function enabled (manual reset)
Emitter
Emitter
Switch S1
+24 V DC
Open: Control output ON
0 V: Control output OFF
S1
Interlock setting input
(Pale purple)
Interlock setting input
(Pale purple)
Test input / Reset input
(Pink)
Test input / Reset input (Pink)
• This function controls the control outputs (OSSD 1 / OSSD 2)
of this light curtain by receiving detection signal of a safety
contact or safety sensor which is connected to the safety
input 1 wire (gray) and the safety input 2 wire (gray / black).
• The control outputs (OSSD 1 / OSSD 2) forcibly turning
OFF when safety input 1 / 2 is OFF.
• A safety contact can be connected at the factory setting
of this light curtain.
• When connecting a safety sensor, the handy-controller
SFC-HC is required. (Note) Furthermore, the number of
safety sensor, which be able to connect this light curtain is 2.
• Series connection is also available when connecting
other SF4C series as a safety sensor to the safety input 1
wire (gray) and the safety input 2 wire (gray / black).
• The safety contacts are available for an emergency stop
switch with two N.C. (Normally Closed) contacts, etc., and
the safety sensor is available for a light curtain or a safety
switch with semiconductor output etc.
Note: This setting is possible for SF4C series Ver.2.1 or later.
S1
Switch S1
0V
Open: Control output ON
+V: Control output OFF
Beam received
condition
at ON state
Output operation
Interlock function enabled (automatic reset)
Emitter
ON with non-operating status
Safety (Emergency stop switch, etc.) Safety input 1: +V
contact Guard closed ON
Safety input 2: 0 V
(Safety switch etc.)
Emitter
Switch S1
+24 V DC
S1
Open
Open: Control output OFF
0 V: Control output ON
Interlock setting input
(Pale purple)
Interlock setting input (Pale purple)
Wiring example for safety contact
Open
Test input / Reset input (Pink)
Open: Control output OFF
+V: Control output ON
Control outputs
(OSSD 1 / OSSD 2)
0 V DC
Wiring example for safety sensor (light curtain etc.)
Receiver 2
Receiver 2
Emitter 2
Safety sensor
(Ex. SF4C)
Emitter 2
Safety sensor
(Ex. SF4C)
+24 V DC
+24 V DC
Safety input 1 (Gray)
Safety input 2 (Gray / Black)
Safety input 1 (Gray)
Safety input 2 (Gray / Black)
Receiver 1
15 ms or less
Short-circuited: Valid
Open: Invalid
0 V (Blue)
Test input / Open (OFF)
Reset input Short-circuited
(ON)
• Safety input
Safety input 2
(Gray / Black)
0V
• When the test input is valid, the control outputs (OSSD 1
/ OSSD 2) become OFF.
• By using this function, malfunction due to extraneous
noise or abnormality in the control outputs (OSSD 1 /
OSSD 2) and the auxiliary output can be determined
even from the equipment side.
• In case of PNP output, normal operation is restored when
the test input / reset input wire (pink) is connected to +V
(for manual reset: open).
• In case of NPN output, normal operation is restored when
the test input / reset input wire (pink) is connected to 0 V
(for manual reset: open).
+24 V DC
+V (Brown)
Safety input 1
(Gray)
S1
Switch S1
Open
Light-ON (Light curtain etc.) Safety input 1, 2
Guard closed ON
When using PNP output: +V
When using NPN output: 0 V
(Safety switch etc.)
Safety
sensor
Emitter
Test input / Reset input (Pink)
Beam received
condition
at OFF state
Control output 1 (Black)
0V
Control output 1 (Black)
Control output 2 (White)
Control output 2 (White)
Receiver 1
Emitter 1
Emitter 1
90 ms or less
ON
SF4C
SF4C
OFF
Do not use the test input function for the
purpose of stopping the machine in which this
light curtain is installed. Failure to do so could
result in death or serious injury.
Safety input 2
(Gray / Black)
Safety input 2
(Gray / Black)
Safety input 1 (Gray)
Safety input 1 (Gray)
Control output 1 (Black)
+V (Brown)
Control output 2 (White)
Control output 1 (Black) K1
0 V (Blue) K1
Control output 2 (White) K2
K2
• Safety input of this light curtain
0V
Vs to Vs-3.5 V: ON
Open: OFF
• Safety input of this light curtain
0 to +2.5 V: ON
Open: OFF
Note: Vs is the applying supply voltage.
18
SF4C
PRECAUTIONS FOR PROPER USE
• Use 0.2 mm2 or more shielded cable when
connecting other SF4C series cable to the
safety input 1 / 2.
• When extending the cable of other SF4C series
which is connected to the safety input 1 / 2, use
the exclusive cable and the total cable length
should be 40.5 m 132.874 ft or less (for each
emitter / receiver). If the total cable length is
exceeding 40.5 m 132.874 ft, the device may
malfunction, resulting in death or serious injury.
• Response time of safety sensor is the sum
of the response time of this light curtain and
safety sensor itself.
This light curtain
Safety sensor
Large multi-purpose indicator function
• The selection of lights up / lights off is available by
applying the large multi-purpose indicator input 1 (gray)
or the large multi-purpose indicator input 2 (gray / black).
Receiver
Receiver
Switch S1
+24 V DC
S1
Large multi-purpose indicator
input 1 (gray)
Response time of this light curtain
9 ms (SF4C-F□)
7 ms (SF4C-H□)
Response time of safety sensor
In case of using SF4C-H□ as safety sensor.
Response time of safety sensor + response time of
this light curtain = 7 ms + 7 ms
= 14 ms
• Use a safety contact which incorporates two
N.C. (Normally Closed) contacts and connect
both the safety input 1 wire (gray) and the
safety input 2 wire (gray / black). Take care
that if only one wire is connected, the light
curtain may not operate normally.
• When using the light curtain in PNP output (or
NPN output), use PNP output (or NPN output)
safety sensor. The control outputs (OSSD 1 /
OSSD 2) become OFF by using wrong output
type of sensor.
• Series connection is also available when
connecting other SF4C series to the safety
input 1 / 2. However, this light curtain does
not incorporate the interference prevention
function. Thus, take sufficient care when
installing the light curtains.
• Use a safety sensor which incorporates a
crossover short-circuit function in the control
output and connect both the safety input 1 wire
(gray) and the safety input 2 wire (gray / black).
Take care that if only one wire is connected, the
device may not operate normally.
• Make sure to connect to +V or 0 V when not
using safety input function.
For PNP output
For NPN output
Safety input
Safety
input
Safety
input
2
wire
Safety
input Safety input 2 wire
function
1 wire (gray) (gray / black)
1 wire (gray) (gray / black)
Safety contact
Connected to +V Connected to 0 V Connected to +V Connected to 0 V
input mode
Safety senser
Connected to +V Connected to +V Connected to 0 V Connected to 0 V
input mode
• It is possible to change the setting of input mode by
using the handy controller SFC-HC.
19
0 V: Lights up in green
Open: Lights off
Large multi-purpose indicator
input 2 (gray / black)
Large multi-purpose indicator
input 2 (gray / black)
S2
S1
Switch S2
+V: Lights up in red
Open: Lights off
Control output 2 (OSSD 2)
S2
Switch S2
0 V: Lights up in red
Open: Lights off
Large multi-purpose indicator
input 1 (gray)
Switch S1
Control output 1 (OSSD 1)
+V: Lights up in green
Open: Lights off
0 V DC
• By wiring the large multi-purpose indicator input 1 (gray)
and the large multi-purpose indicator input 2 (gray /
black) to the auxiliary output wire (yellow-green / black)
or the muting lamp output wire (red), the outputs operate
simultaneously with the outputs.
When used in conjunction with auxiliary output
Receiver
Emitter
When used as muting lamps
Receiver
Emitter
Auxiliary output
(Yellow-green / Black)
Muting lamp output (red)
Large multi-purpose indicator input 1 (gray) or
Large multi-purpose indicator input 2 (gray / black)
Large multi-purpose indicator input 1 (gray) or
Large multi-purpose indicator input 2 (gray / black)
• Connected to auxiliary output
Auxiliary output is ON: Lights up
Auxiliary output is OFF: Lights off
• Connected to muting lamp output
Muting lamp output is ON: Lights up
Muting lamp output is OFF: Lights off
• It is also possible to change the large multi-purpose
indicator operation setting (lights up, blinks, lights off) by
using the handy-controller SFC-HC.
SF4C
PRECAUTIONS FOR PROPER USE
Auxiliary output (Non-safety output)
In case of setting the external device monitoring function to disabled
• This light curtain incorporates the auxiliary output for the nonsafety output. The auxiliary output is incorporated in the emitter.
Normal operation
Auxiliary output setting
Test
input
Negative logic of the control
outputs (OSSD 1 / OSSD 2)
ON
Emitter
Control outputs (OSSD 1 / OSSD 2)
Lockout
Light received Light interrupted
OFF
ON
• Connect the external device monitoring input (yellowgreen) to the auxiliary output (yellow-green / black). At
this time, set the auxiliary output as “negative logic of
control outputs (OSSD 1, OSSD 2)” (factory setting).
• The auxiliary output (yellow-green / black) cannot be
connected to external devices.
ON
Receiver
Emitter
Emitter
Auxiliary output
(Yellow-green / Black)
External device monitoring
input (Yellow-green)
+24 V DC
Auxiliary output
(Yellow-green / Black)
+V (Brown)
Auxiliary output
Load
(Yellow-green / Black)
Load
0 V (Blue)
• It is also possible to set the external device monitoring
function to disabled by using the handy-controller
SFC-HC.
0 V DC
Note: When the external device monitoring function is set disabled, the
auxiliary output cannot be used. For details, refer to “External device
monitoring function” listed below.
T
Beam received Beam received
condition
Beam interrupted
T
Beam received Beam received
condition
Beam interrupted
90 ms or less
ON
Control outputs
(OSSD 1, OSSD 2) OFF
90 ms or less
External device
monitoring input
ON
Control outputs
(OSSD1, OSSD2)
300 ms or less
ON
OFF
300 ms or less
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
OFF
30 ms or less
ON
Auxiliary output
(Negative logic of the OSSD) OFF
10 ms or less
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
Do not use the auxiliary output for the purpose of stopping
the machine in which the SF4C series is installed. Failure
to do so could result in death or serious injury.
• The time set for external light curtain monitoring is 300 ms
or less. Exceeding 300 ms turns the light curtain into lockout
status. It can be set within 100 to 600 ms (in units of 10 ms)
by using the handy-controller SFC-HC.
T
Beam received Beam received
condition
Beam interrupted
• It is also possible to change the auxiliary output by
using the handy-controller SFC-HC.
ON
Control outputs
(OSSD 1, OSSD 2) OFF
External device
monitoring input
External device monitoring function
• This is the function for checking whether the external safety
relay connected to the control outputs (OSSD 1, OSSD 2)
perform normally in accordance with the control outputs (OSSD
1, OSSD 2) or not. Monitor the contact “b” of the external safety
relay, and if any abnormality such as deposit of the contact, etc.
is detected, change the status of the light curtain into lockout
one, and turn OFF the control outputs (OSSD 1, OSSD 2).
In case of setting the external device monitoring function to enabled
300 ms
ON
OFF
Lockout status
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
Beam received Beam received
condition
Beam interrupted
90 ms or less
ON
Control outputs
(OSSD 1, OSSD 2) OFF
External device
monitoring input
ON
OFF
300 ms
Lockout status
• Connect the external device monitoring input (yellow-green)
to the external safety relay connected the control outputs
(OSSD 1, OSSD 2).
Receiver
Receiver
+24 V DC
+24 V DC
+V (Brown)
+V (Brown)
External device monitoring
input (Yellow-green)
K1
Control output 1 (Black)
K2
Control output 2 (White)
Control output 1 (Black)
Control output 2 (White)
K1
K2
K1
External device monitoring
input (Yellow-green)
K1
K2
K2
0 V (Blue)
0 V (Blue)
0V
0V
20
SF4C
PRECAUTIONS FOR PROPER USE
Muting function
• Incorrect use of the muting control may cause
accidents. Please understand the muting
control fully, and use it. As for the muting
control, the following international standards
define the requirements.
ISO 13849-1 (JIS B 9705-1)
IEC 61496-1 (UL 61496 / JIS B 9704-1)
IEC 60204-1 (JIS B 9960-1)
IEC / TS 62046
EN 415-4
ANSI B11.19-1990
ANSI / RIA R15.06-1999
• Use the muting control while the machine
cycle is not in danger mode. Maintain safety
with the other measure while the muting
control is activated.
• For the application that the muting control is
activated when a workpiece passes through
the sensor, place the muting sensor so that
the conditions for the muting control cannot
be satisfied by intrusion of personnel when
the workpiece is passing through the sensor
or the workpiece is not passing through it.
• The muting lamp should be installed in a
position where it can always be seen by
operators who set or adjust the machine.
• Be sure to check the operation of the muting
function before its use. Furthermore, check
the state of the muting lamp (cleanliness or
brightness etc.).
• The muting function turns the safety function of this
light curtain into disabled temporarily. When the control
outputs (OSSD 1, OSSD 2) are ON, this function is
available for passing the workpiece through the sensing
area of the light curtain without stopping the machinery.
Notes: 1) By using handy-controller SFC-HC, and connecting normally open
(N.O.) type muting sensor to muting input A, and normally closed
(N.C.) type muting sensor to muting input B, then muting function
can be used for 0 to 3 sec.
2) Using handy-controller SFC-HC can configure muting lamp
diagnosis function. If setting muting lamp diagnosis function to
ineffective, muting function continues even when the lamp is out or
not connected.
3) The muting time of this light curtain is unlimited by factory setting.
Using the handy-controller SFC-HC, muting time can be set in 1
sec. unit from 1 to 600 sec.
Specification for muting sensor
Operation when Operation when
sensor is ON
sensor is OFF
N.O. (Normally open) type
ON with “Dark-ON” condition
(photoelectric sensor, etc.)
ON with “Normally open” condition
(inductive proximity sensor, etc.)
ON with object contacted condition
(position switch, etc.)
0 V or +V
Open
• Be sure to use the muting sensor that satisfies
the above table “Specification for muting
sensor”. If the other muting sensor not
satisfying the specification above, the muting
function might become enabled with the timing
that the machine designer cannot expect and
could result in serious injury or death.
• It is recommended that two muting lamps
should be connected in parallel. However,
take care not to exceed 6 W in total.
Installation condition of muting sensor
Muting sensor B
Guard
Light curtain
Muting sensor C
Muting sensor D
Muting sensor A
S (m/sec.)
Muting function enabled
Sensing object
Receiver
Receiver
Guard
Emitter
Emitter
1
+24 V DC
+24 V DC
+V (Brown)
1
+V (Brown)
2
Safety zone
Muting lamp output (Red)
Muting lamp output (Red)
Muting input 1 (Light blue / White)
Muting input 1 (Light blue / White)
Muting input 2 (Light blue / Black)
Muting input 2 (Light blue / Black)
1
2
0V
• The muting function becomes valid when all the
conditions listed below are satisfied:
1 The control outputs (OSSD 1, OSSD 2) shall be ON.
2 The safety input 1 / 2 shall be ON.
3 Time difference between the time during muting input
1 / 2 becomes ON from OFF (open) and the time
during muting input 1 / 2 becomes OFF (open) from
ON should be between 0.03 to 3 sec. (Note 1)
• The lamp to be connected to the muting lamp output shall
be an incandescent lamp of 1.5 to 6 W. (When the muting
lamp diagnosis function is enabled) (Note 2)
• The following devices, photoelectric sensor with
semiconductor output, inductive proximity sensor,
position switch on N.O. (Normally open) contact, etc. are
available for applying to the muting sensor.
21
3
3
Dangerous zone
Shorten the distances between muting sensors A to
C and between B to D than the whole length of the
sensing object.
The time of the sensing object to be passed through
the muting sensors A to B shall be 0.03 to 3 sec.
Distance between A and B (m) < S (m/sec.) × 3 (sec.)
S: The moving speed (m/sec.) of the sensing object
The time of the sensing object to be passed through
the muting sensors C to D shall be under 3 sec.
Distance between C and D (m) < S (m/sec.) × 3 (sec.)
S: The moving speed (m/sec.) of the sensing object
SF4C
PRECAUTIONS FOR PROPER USE
Muting
sensor A
Muting
sensor B
Muting
sensor C
Muting
sensor D
Emitter
Emitter
+24 V DC
+V
+V
Test input / Reset input (Pink)
+V (Brown)
Override input (Yellow)
To muting input 1
of light curtain
To muting input 2
of light curtain
Override input (Yellow)
Muting
sensor A
0V
To muting input 1
of light curtain
Muting
sensor C
0V
Muting
sensor B
0V
Muting
sensor D
0V
To muting input 2
of light curtain
ON
OFF
Muting sensor B
ON
30 ms to less than 3 sec. (Note 1)
If one of the four conditions above becomes valid or
timing exceeds 60 sec. (Note 2), the override function
becomes valid.
OFF
Muting sensor C
ON
OFF
Muting sensor D
ON
OFF
Muting function
ON
OFF
Beam received Beam received
condition of
Beam interrupted
light curtain
Control outputs
(OSSD 1, OSSD 2)
0V
• The override function becomes valid when all the
conditions listed below are satisfied:
1 The safety input 1 / 2 shall be ON.
2 The signal shall be input to either muting input 1 or 2,
or to both of the inputs.
3 The override input (yellow) shall be connected to +V
(0 V when using NPN output), and the test input / reset
input shall be opened (3 sec. continuously).
4 When the muting lamp diagnosis function is enabled,
an incandescent lamp of 1.5 to 6 W shall be
connected. (Factory setting is disabled) (Note 1)
Muting sensor A
0 V (Blue)
Test input / Reset input (Pink)
50 ms to 1 sec.
(Note 2)
T
Notes: 1) Using handy-controller SFC-HC can configure muting lamp
diagnosis function. If setting muting lamp diagnosis function to
ineffective, muting function continues even when the lamp is out or
not connected.
2) By using handy-controller SFC-HC, a change between 1 and
600 sec. by 1 sec. per unit is possible.
3) The override function operates only when the automatic reset is
ON (the interlock is disabled).
ON
OFF
• Make sure to operate the system for starting
override function manually. Furthermore, the
system shall be placed in area where all of
the dangerous zone shall be comprehend and
outside of the dangerous zone.
• Using override function, make sure that there
exist no operator in the dangerous zone,
which may result in death or serious injury.
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
Notes: 1) By using handy-controller SFC-HC, and connecting normally open
(N.O.) type muting sensor to muting input A, and normally closed
(N.C.) type muting sensor to muting input B, then muting function
can be used for 0 to 3 sec. This setting is possible for SF4C series
Ver.2.1 or later.
2) If the muting lamp does not light up even if 1 sec. or more when
the muting lamp diagnosis function is valid, the muting function
becomes invalid. When the muting lamp diagnosis function is
invalid, the muting function becomes valid 50 ms to 1 sec. after the
input conditions of the muting sensor A (C) and B (D) were satisfied.
• It is possible to set the muting function into disabled
per beam channel respectively and to specify the input
order of the muting inputs 1, 2 to be set into enabled by
using the handy-controller SFC-HC.
Within 1 sec.
Test input /
Reset input
Open
Short-circuited
Open
Override input
Short-circuited
Override function
• This function sets the safety function of this light curtain
enabled forcibly. When using the muting function, the
override function can be used to start the machinery at
times such as when the control outputs (OSSD 1 and
OSSD 2) are OFF or when the muting sensors are ON
when the line is to be started.
ON
Muting
Sensor A / C
OFF
Muting
Sensor B / D
OFF
ON
Override function
ON
3 to 4 sec. (Note 1)
T
Override input time: Max. 60 sec. (Note 2)
OFF
Sensing object
Within the
protection area
(
)
Absent
Present
ON
Control outputs
(OSSD 1, OSSD 2) OFF
90 ms or less
T: 9 ms or less (SF4C-F□) / 7 ms or less (SF4C-H□)
Notes: 1) This is when the muting lamp diagnosis function is valid. If the
muting lamp does not light up even if 1 sec. or more is passed,
the override function becomes invalid. When the muting lamp
diagnosis function is invalid, the muting function becomes valid
3 sec. after the input conditions of the muting sensor A (C) and
B (D) were satisfied.
2) By using handy-controller SFC-HC, a change between 1 and
600 sec. by 1 sec. per unit is possible.
22
SF4C
PRECAUTIONS FOR PROPER USE
Part description and function
Indicator section of emitter
Digital error
indicator
Top end
Model
information
Incident light intensity
indicator [STB]
Fault indicator [FAULT]
PNP indicator [PNP]
A
NPN indicator [NPN]
B
Test input indicator [TEST]
C
Beam-axis alignment
indicator
[RECEPTION]
D
Safety input 1 indicator [S1]
Operation indicator
[OSSD]
Safety input 2 indicator [S2]
A
Beam-axis
alignment
indicator
[RECEPTION]
B
C
Large
multi-purpose
indicator
D
Note: SF4C-F15(-J05) does not incorporate the digital display.
PNP indicator [PNP]
A
NPN indicator [NPN]
B
Test input indicator [TEST]
C
Beam-axis alignment
indicator
[RECEPTION]
Safety input 2 indicator [S2]
Digital error
indicator
Operation indicator
[OSSD]
Indicator section of receiver
Digital error
indicator
Incident light intensity
indicator [STB]
Fault indicator [FAULT]
PNP indicator [PNP]
A
NPN indicator [NPN]
B
Function setting indicator [FUNCTION]
C
Interlock indicator [INTERLOCK]
D
Sensing surface side
Description
Function
When the large multi-purpose indicator input 1 is valid:
lights up in red
Large multi-purpose indicator When the large multi-purpose indicator input 2 is valid:
(Red / Green) (Note 1)
lights up in green
When the large multi-purpose indicator input invalid:
OFF
When stable light is received: lights up in green
Incident light intensity indicator
When unstable light is received: lights up in orange
(Orange / Green) [STB]
When light is interrupted: OFF (Note 2)
Beam-axis alignment
indicator
[RECEPTION]
A
B
Muting input 1 indicator [MU1]
Muting input 2 indicator [MU2]
OSSD indicator [OSSD]
Note: SF4C-F15(-J05) does not incorporate the digital display.
Beam-axis alignment
indicator (Red / Green)
[RECEPTION]
C
Incident light intensity
indicator [STB]
Fault indicator [FAULT]
PNP indicator [PNP]
A
NPN indicator [NPN]
B
Function setting indicator [FUNCTION]
C
Interlock indicator [INTERLOCK]
D
Muting input 1 indicator [MU1]
Muting input 2 indicator [MU2]
Digital error
indicator
Left side Right side
Common to emitter and receiver
D
Safety input 1 indicator [S1]
Bottom end
Incident light intensity
indicator [STB]
Fault indicator [FAULT]
Large
multi-purpose
indicator
D
Beam-axis alignment
indicator
[RECEPTION]
Digital error indicator (Red)
When light curtain top receives light: lights up in red
When light curtain top end receives light: blinks in red
When control outputs (OSSD 1 / OSSD 2) are ON: light up in green
When light curtain upper middle receives light:
lights up in red
When control outputs (OSSD 1 / OSSD 2) are ON:
lights up in green
When light curtain lower middle receives light:
lights up in red
When control outputs (OSSD 1 / OSSD 2) are ON:
lights up in green
When light curtain bottom receives light:
lights up in red
When light curtain bottom end receives light:
blinks in red
When control outputs (OSSD 1 / OSSD 2) are ON:
lights up in green
When light curtain is lockout: lights up for incident error content
Fault indicator (Yellow) [FAULT] When fault occurs in the light curtain: lights up or blinks
OSSD indicator [OSSD]
PNP indicator (Orange) [PNP] When PNP output is set: lights up
NPN indicator (Orange) [NPN] When NPN output is set: lights up
Emitter
Description
Operation indicator
(Red / Green)
[OSSD] (Note 3)
Receiver
Function
Lights up while light curtain operation is as follows
[sequential operation]:
When control outputs (OSSD 1 / OSSD 2) are OFF:
lights up in red
When control outputs (OSSD 1 / OSSD 2) are ON:
lights up in green
Description
OSSD indicator
(Red / Green) [OSSD]
Function setting indicator
(Orange) [FUNCTION]
Interlock indicator
(Yellow) [INTERLOCK]
Muting input 1 indicator
(Orange) [MU1]
Muting input 2 indicator
(Orange) [MU2]
Function
When control outputs (OSSD 1 / OSSD 2) are OFF:
lights up in red
When control outputs (OSSD 1 / OSSD 2) are ON:
lights up in green
When handy-controller is connected: blinks
When blanking function is enabled: lights up (Note 4)
When interlock is enabled: lights up
When interlock is disabled: OFF
When muting input 1 is valid: lights up
When muting input 1 is invalid: OFF
When muting input 2 is valid: lights up
When muting input 2 is invalid: OFF
Test input indicator
When test input is valid: lights up
(Orange) [TEST]
When test input is invalid: OFF
Safety input 1 indicator
When safety input 1 is valid: lights up
(Orange) [S1]
When safety input 1 is invalid: OFF
Safety input 2 indicator
When the safety input 2 is valid: lights up
(Orange) [S2]
When the safety input 2 is invalid: OFF
Notes: 1) It is also possible to change the large multi-purpose indicator operation setting (lights up, blinks, lights off) by using the handy-controller SFC-HC.
2) The status when light is interrupted refers to the status that the some obstacle is existed in the sensing area.
3) Since the color of the operation indicator changes according to the ON / OFF status of the control outputs (OSSD 1, OSSD 2), the operation indicator is
marked as “OSSD” on the light curtain.
4) The blanking function is set by using the handy-controller SFC-HC.
5) The description given in [ ] is marked on the light curtain.
23
SF4C
PRECAUTIONS FOR PROPER USE
• When this light curtain is used in the “PSDI
mode”, an appropriate control circuit must be
configured between this light curtain and the
machinery. For details, be sure to refer to the
standards or regulations applicable in each
region or country.
Safety distance
• Calculate the safety distance correctly, and
always maintain a distance which is equal to
or greater than the safety distance, between
the sensing area of this light curtain and the
dangerous parts of the machinery. (Please
check the latest standards for the equation.)
If the safety distance is miscalculated or if
sufficient distance is not maintained, there is
a danger of serious injury or death.
• Before designing the system, refer to the
relevant standards of the region where this
device is to be used and then install this
device.
• This catalog is a guide to select a suitable product. Be
sure to read instruction manual attached to the product
prior to its use.
• Both emitter and receiver are adjusted in combination at
factory setting, please apply both emitter and receiver
with the same serial No. The serial No. is indicated on
the plates of both emitter and receiver.
(Indicated under model No.)
• Make sure to carry out the test run before regular operation.
• Do not install this light curtain with a machine whose
operation cannot be stopped immediately in the middle of
an operation cycle by an emergency stop equipment.
Dangerous part
of machine
Emitter
S
Receiver
Beam axis
S: Safety distance
Sensing area
• Make sure to install this light curtain such that
any part of the human body must pass through its
sensing area in order to reach the dangerous parts
of the machinery. If the human body is not detected,
there is a danger of serious injury or death.
• Do not use any reflective type or retroreflective type
arrangement.
• Furthermore, never use this light curtain facing
several receivers towards one emitter or vice versa.
Example of correct installation
Dangerous part
Sensing area
Protective structure
Dangerous part
Sensing area
Example of incorrect installation
Dangerous
part
Sensing area
Dangerous
part
The sizes of the minimum sensing objects for
this light curtain vary depending on whether
or not the floating blanking function is being
used. Calculate the safety distance with the
proper size of the minimum sensing object and
appropriate equation.
Size of minimum sensing object when applying floating blanking function
Invalid
Setting (Note 1)
1 beam channel 2 beam channels 3 beam channels
SF4C-F□(-J05)
ø14 mm ø24 mm ø34 mm
(Min. sensing object ø14 mm) ø0.551 in ø0.945 in ø1.339 in
SF4C-H□(-J05)
ø25 mm ø45 mm ø65 mm
(Min. sensing object ø25 mm) ø0.984 in ø1.772 in ø2.559 in
Note: Refer to p.6 for details of the floating blanking function.
ø44 mm
ø1.732 in
ø85 mm
ø3.346 in
• Safety distance is calculated based on the following
equation when a person moves perpendicular (normal
intrusion) to the sensing area of the light curtain. In case
the intrusion direction is not perpendicular to the sensing
area, be sure to refer to the relevant standard (regional
standard, specification of the machine, etc.) for details of
the calculation. (Please check the latest standards for the
equation.)
For use in Europe (EU) (as EN 999)] (Also applicable to ISO 13855 / JIS B 9715)
For intrusion direction perpendicular to the sensing area
Sensing area
• Equation 1
S=K×T+C
S: Safety distance (mm)
Minimum required distance between the sensing area
surface and the dangerous parts of the machine
K: Intrusion velocity of operator’s body or object (mm/sec.)
Normally taken as 2,000 (mm/sec.) for calculation
T: Response time of total equipment (sec.)
T = Tm + TSF4C
Tm: Maximum halting time of machinery (sec.)
TSF4C: Response time of the SF4C series 0.007 (sec.)
C: Additional distance calculated from the size of the
minimum sensing object of the light curtain (mm)
However, the value of “C” cannot be less than 0.
C = 8 × (d – 14)
d: Minimum sensing object diameter (mm)
24
SF4C
PRECAUTIONS FOR PROPER USE
• For calculating the safety distance “S”, there are the
following five cases.
First calculate by substituting the value K = 2,000
(mm/sec.) in the equation previous. Then, classify
the obtained value of “S” into three cases, 1) S <
100, 2) 100 ≤ S ≤ 500, and 3) S > 500. For Case 3)
S > 500, recalculate by substituting the value K =
1,600 (mm/sec.). After that, classify the calculation
result into two cases, 4) S ≤ 500 and 5) S > 500. For
details, refer to the instruction manual enclosed with
this product.
• When this light curtain is used in the “PSDI mode”, an
appropriate safety distance “S” must be calculated.
For details, be sure to refer to the standards or
regulations applicable in each region or country.
• Equation 1
S=K×T+C
S: Safety distance (mm)
K: Intrusion velocity of operator’s body or object (mm/sec.)
Taken as 1,600 (mm/sec.) for calculation
T: Response time of total equipment (sec.)
T = Tm + TSF4C
Tm: Maximum halting time of machinery (sec.)
TSF4C: Response time of the SF4C series 0.007 (sec.)
C: Additional distance calculated from the size of the
minimum sensing object of the light curtain (mm)
C = 850 (mm) (Constant)
For use in the United States of America (as per ANSI/RIA 15.06)
• Equation 2
S = K× (TS + TC + TSF4C + Tbm) + Dpf
S: Safety distance (mm)
Minimum required distance between the sensing area
surface and the dangerous parts of the machine
K: Intrusion velocity {Recommended value in OSHA is 63
(inch/sec.) ≈ 1,600 (mm/sec.)}
ANSI/RIA 15.06 does not define the intrusion velocity
“K”. When determining “K”, consider possible factors
including physical ability of operators.
TS: Halting time calculated from the operation time of the
control element (air valve, etc.) (sec.)
TC: Maximum response time of the control circuit required
for functioning the brake (sec.)
TSF4C: Response time of light curtain (sec.)
Tbm: Additional halting time tolerance for the brake
monitor (sec.)
The following equation holds when the machine is
equipped with a brake monitor.
Tbm = Ta – (Ts + Tc)
Ta: Setting time of brake monitor (sec.)
When the machine is not equipped with a brake
monitor, it is recommended that 20 % or more of
(Ts + Tc) is taken as additional halting time.
Dpf: Additional distance calculated from the size of the
minimum sensing of the
Dpf = 61.2 mm 2.409 in (SF4C-H□), 23.8 mm 0.937
in (SF4C-F□)
Dpf = 3.4 × (d – 0.276) (inch)
≈ 3.4 × (d – 7) (mm)
d: Min. sensing object diameter 0.985 (inch) ≈ 25 (mm) (SF4C-H□)
Min. sensing object diameter 0.552 (inch) ≈ 14 (mm) (SF4C-F□)
• If the floating blanking function is used, min. sensing
object become larger.
When d > 64 mm 2.5 in, Dpf = 900 mm 3 ft as per
ANSI/RIA 15.06
25
Output waveform [Control outputs (OSSD 1, OSSD 2) ON]
• Since the receiver performs the self-diagnosis of the
output circuit when the light curtain is in beam received
condition (ON status), the output transistor becomes OFF
status periodically. (Refer to the figure below.)
When the OFF signal is fed back, the receiver judges
the output circuit as normal. When the OFF signal is not
fed back, the receiver judges either the output circuit or
wiring as error, and the control outputs (OSSD 1,
OSSD 2) maintain OFF status.
Since the OFF signal of this light curtain might
cause malfunction, perform the connection
paying attention to the input response time of
the machine to be connected to this light curtain.
Beam
Beam
received
received
Beam
condition interrupted
90 ms approx. or less
3.4 ms approx. (SF4C-F□)
2.5 ms approx. (SF4C-H□)
Control output 1 ON
(OSSD 1)
OFF
35 to 75 μs approx.
Control output 2 ON
(OSSD 2)
OFF
20 μs approx.
35 to 75 μs approx.
310 μs approx.
35 to 75 μs approx.
40 μs approx.
310 μs approx.
45 μs approx.
20 μs approx.
40 μs approx.
35 to 75 μs approx.
* This OFF pulse appears in every 5 sec. cycle.
Influence of reflective surfaces
If there exists a reflective surface in the place
where this light curtain to be installed, make
sure to install this light curtain so that reflected
light from the reflective surface does not enter
into the receiver, or take countermeasures
such as painting, masking, roughening, or
changing the material of the reflective surface,
etc. Failure to do so may cause the device not
to detect, resulting in death or serious injury.
• Install this light curtain at a distance of 0.16 m 0.525 ft
or more from reflective surfaces such as metal walls,
floors, ceilings, sensing objects, covers, panels or glass
surfaces.
Side view
Top view
Reflective surface
Reflective ceiling
Emitter
0.16 m 0.525 ft
Receiver
Emitter
Operating range
0.1 to 3 m
0.328 to 9.843 ft
0.16 m 0.525 ft
Reflective floor
0.16 m 0.525 ft
Operating range
0.1 to 3 m
0.328 to 9.843 ft
Receiver
SF4C
PRECAUTIONS FOR PROPER USE
Handy-controller
Others
This light curtain enables to set each function
using the handy-controller SFC-HC. Among
the functions, the contents related to the safety
distance such as the size of the minimum sensing
object and response time are varied depending
on the setting condition. When setting each
function, re-calculate the safety distance, and
make enough space larger than the calculated
safety distance. Failure to do so might cause
the accident that the device cannot stop quickly
before reaching the dangerous area of the
machinery, resulting in the serious injury or death.
• Refer to the instruction manual enclosed with the
handy-controller for details of the function settings for
using handy-controller SFC-HC.
Troubleshooting quick reference sheet
Digital error
indicator
Possible cause
Incorrect wiring.
Affected by large noise.
Handy-controller setting error.
• Our products have been developed / produced for
industrial use only.
• Do not use during the initial transient time (2 sec.) after
the power supply is switched on.
• Avoid dust, dirt and steam.
• Take care that the sensor does not come in direct contact
with water, oil, grease, or organic solvents, such as,
thinner, etc.
• Take care that the sensor is not directly exposed to
fluorescent lamp from a rapid-starter lamp or a high
frequency lighting device, as it may affect the sensing
performance.
Disclaimer
• The applications described in the catalog are all intended
for examples only. The purchase of our products
described in the catalog shall not be regarded as
granting of a license to use our products in the described
applications. We do NOT warrant that we have obtained
some intellectual properties, such as patent rights,
with respect to such applications, or that the described
application may not infringe any intellectual property
rights, such as patent rights, of a third party.
Incorrect number of beam channels of emitter and receiver.
Interlock setting input wire (pale purple) or test input / reset
input wire (pink) connected incorrectly.
Affected by extraneous light, or mutual interference occurring.
Safety input 1 (gray) or safety input 2 (gray / black)
connected incorrectly.
Control output 1 (black), control output 2 (white) connected
incorrectly.
Output polarity setting wires (shield) connected incorrectly.
Output polarity setting wire is disconnected or short-circuited
to other wire.
External device (safety relay, etc.) is connected incorrectly or
welding, out of the specified range.
Auxiliary output wire (yellow-green / black) and external
device monitoring input wire (yellow-green) are disconnected.
Auxiliary output wire (yellow-green / black) is disconnected or short-circuited.
Auxiliary output setting is changed by SFC-HC.
Wiring, voltage or supply capacity is incorrected.
Muting lamp output wire (red) connected incorrectly.
Muting lamp is out of the specified range.
Muting lamp output circuit malfunction.
Control output 1 (black), control output 2 (white) connected
incorrectly or flowing overcurrent.
Emitter is in lockout status.
Affected by noise.
Internal circuit is broken down.
Synchronization + wire (orange) or synchronization – wire
(orange / black) connected incorrectly.
Receiver or emitter malfunction.
Receiver is in lockout status.
[TEST]
Test input / reset input wire (pink) is open when selecting
automatic reset.
Test input / reset input wire (pink) is connected to 0 V or +V
when selecting manual reset.
* Refer to the instruction manual for details.
26
SF4C
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
SF4C-F□
□ SF4C-H□
Light curtain
Mounting bracket assembly dimensions
Mounting drawing for the light curtains using the standard mounting brackets MS-SFC-1 (accessory).
30
1.181
10 0.394
30
13.2 0.520
1.181
t 2 t 0.079 10 0.394
7.7
(0.303
)
5.4
0.213
(
)
18
0.709
Display
section (Note)
Large
Multi-purpose
indicator
5.4
0.213
(
)
13
0.512
21
0.827
30
1.181
7.7
(0.303
)
12
0.472
Display
section (Note)
(
)
DCB A
Large
Multi-purpose
indicator
(
Beam
pitch
)
E
AB
(
88
3.465
Large
Multi-purpose
indicator
13
0.512
Large
Multi-purpose
indicator
)
Large
Multi-purpose
indicator
(
88
3.465
)
Receiver
Model No.
A
B
C
88
(3.465
)
Large
Multi-purpose
indicator
E
Large
Multi-purpose
indicator
Beam
pitch
F
10
0.394
Emitter
D
88
(3.465
)
E
BA
10
0.394
Emitter
13
0.512
50.5
(1.988
)
F
16 10
0.630 0.394
13.2 0.520
t 2 t 0.079
12
0.472
Display
section (Note)
Large
Multi-purpose
indicator
F
16 10
0.630 0.394
7.7
(0.303
)
21
0.827
Beam
pitch
F
30
1.181
18
(0.709
)
50.5
(1.988
)
88
3.465
88
(3.465
)
21
0.827
21
(0.827
)
50.5
(1.988
)
88
3.465
13.2 0.520
t 2 t 0.079
18
(0.709
)
21
(0.827
)
50.5
(1.988
)
88
(3.465
)
13.2 0.520
t 2 t 0.079
18
0.709
Display
section (Note)
13
0.512
21
(0.827
)
DCB A
7.7
(0.303
)
Receiver
SF4C-F15(-J05) SF4C-H8(-J05) 140 5.512 160 6.299 172 6.772 184 7.244 130 5.118
45
(1.772
)
SF4C-F23(-J05) SF4C-H12(-J05) 220 8.661 240 9.449 252 9.921 264 10.394 210 8.268
SF4C-F31(-J05) SF4C-H16(-J05) 300 11.811 320 12.598 332 13.071 344 13.543 290 11.417
ø15.6
ø0.614
SF4C-F39(-J05) SF4C-H20(-J05) 380 14.961 400 15.748 412 16.220 424 16.693 370 14.567
ø6
0 236
Digital error
indicator
SF4C-F47(-J05) SF4C-H24(-J05) 460 18.110 480 18.898 492 19.370 504 19.842 450 17.717
SF4C-F55(-J05) SF4C-H28(-J05) 540 21.260 560 22.047 572 22.520 584 22.992 530 20.866
Model No.
F
SF4C-F63(-J05) SF4C-H32(-J05) 620 24.409 640 25.197 652 25.669 664 26.142 610 24.016
SF4C-F□
10 0.394
Note: Measurement of drawing above is display section of SF4C-H□. In case of
SF4C-F□, the position of digital indicator (red) is different as right figure. Also,
digital indicator (red) is not incorporated in SF4C-F15□.
SF4C-H□
20 0.787
MS-SFC-1
Standard mounting bracket (Accessory)
30
1.181
t2
t 0.079
10
0.394
MS-SFC-2
NA2-N compatible mounting bracket (Optional)
t2
t 0.079
6
0.236
11.8 5.4
0.465 0.213
2-ø4.5
ø0.177
14.8 6.5
0.583 0.256
21
34
0.827 1.339
M3 countersunk screw mounting hole
(for main body mounting)
Material: Stainless steel (SUS304)
Net weight: 32 g approx. (4 pcs.)
Package weight: 35 g appox.
Four bracket set
Four M3 (length 4 mm 0.157 in)
countersunk screws are attached.
27
30
1.181
18 0.709
2 0.079
7.5
0.295
5
0.197
37
1.457
22.5
0.886
M3 countersunk screw mounting hole
(for main body mounting)
Material: Stainless steel (SUS304)
Net weight: 36 g approx. (4 pcs.)
Package weight: 40 g appox.
Four bracket set
Four M3 (length 4 mm 0.157 in)
countersunk screws are attached.
SF4C
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
SF4C-F□
SF4C-H□
□ SF4C-H
Light curtain
Mounting bracket assembly dimensions
Mounting drawing for the light curtains using the versatile brackets MS-SFC-C3 (optional) and intermediate supporting bracket for versatile
brackets MS-SFC-F4 (optional).
7.5
( 0.295
)
Display
section
(Note)
15
( 0.591
)
7.5
( 0.295
)
MS-SFC-3
2 0.079 Display
section
6.5 0.256 (Note)
15
( 0.591
)
2 0.079
6.5 0.256
MS-SFC-3
Display
section
(Note)
Display
section
(Note)
MS-SFC-3
MS-SFC-3
(22 0.866)
Large
Multi-purpose
indicator
Large
Multi-purpose
indicator
Large
Multi-purpose
indicator
MS-SFC-4
D A C
8
0.315
30
1.181
42
1.654
12.7
0.500
15
( 0.591
)
7.5
( 0.295
)
6.5
0.256
B
12.7
0.500
15
( 0.591
)
7.5
( 0.295
)
25.7
1.012
Emitter
Inter mediate
supporting bracket
SF4C-F15(-J05) SF4C-H8(-J05)
–
SF4C-F23(-J05) SF4C-H12(-J05)
–
SF4C-F31(-J05) SF4C-H16(-J05)
–
SF4C-F39(-J05) SF4C-H20(-J05)
–
SF4C-F47(-J05) SF4C-H24(-J05)
–
SF4C-F55(-J05) SF4C-H28(-J05)
○
○
SF4C-F63(-J05) SF4C-H32(-J05)
6.5 0.256
2 0.079
25.7
1.012
Receiver
Model No.
Large
Multipurpose
indicator
A
8
0.315
21
0.827
MS-SFC-4
A’
6.5
0.256
B
175
–
6.890
255
–
10.039
335
–
13.189
415
–
16.339
495
–
19.488
575
238 to 338
22.638 9.370 to 13.307
655
278 to 378
25.787 10.945 to 14.882
30
1.181
B’
(22 0.866)
(22 0.866)
6.5 0.256
2 0.079
30
1.181
42
1.654
2 0.079
12.7 0.500
25.7 1.021
42
1.654
8
0.315
21
0.827
B’
6.5
0.256
12.7 0.500
25.7 1.021
Emitter
Receiver
C
D
Model No.
Inter mediate
supporting bracket
190
7.480
270
10.630
350
13.780
430
16.929
510
20.079
590
23.228
670
26.378
160
6.299
240
9.449
320
12.598
400
15.748
480
18.898
560
22.047
640
25.197
SF4C-F15(-J05) SF4C-H8(-J05)
–
SF4C-F23(-J05) SF4C-H12(-J05)
–
SF4C-F31(-J05) SF4C-H16(-J05)
–
SF4C-F39(-J05) SF4C-H20(-J05)
–
SF4C-F47(-J05) SF4C-H24(-J05)
–
SF4C-F55(-J05) SF4C-H28(-J05)
○
○
Notes: 1) Measurement of drawing above is display section of SF4C-H□ In case
of SF4C-F□, the position of digital indicator (red) is different.
Also, digital indicator (red) is not incorporated in SF4C-F15□.
SF4C-F63(-J05) SF4C-H32(-J05)
A'
B'
D
116
–
4.567
196
–
7.717
276
–
10.866
356
–
14.016
436
–
17.165
516
209 to 309
20.315 8.228 to 12.165
596
249 to 349
23.465 9.803 to 13.740
160
6.229
240
9.449
320
12.598
400
15.748
480
18.898
560
22.047
640
25.197
2) Be sure to mount MS-SFC-4 when using SF4C-F55(-J05)/F63(-J05)/
H28(-J05)/H32(-J05).
MS-SFC-3
Versatile bracket (Optional)
14.5 0.571
2-ø4.5
ø0.177
Large
Multi-purpose
indicator
D
A’
6.5
0.256
21
0.827
30
1.181
42
1.654
6.5 0.256
2 0.079
D
MS-SFC-4
8
0.315
21
0.827
B
Large
Multipurpose
indicator
MS-SFC-4
D A C
6.5
0.256
Large
Multi-purpose
indicator
(22 0.866)
Large
Multipurpose
indicator
30 1.181
18 0.709
2 0.079
(
6
0.236
5 0.197
6.5 0.256
Material: Stainless steel (SUS304)
Net weight: 75 g approx. (4 pcs.)
Package weight: 90 g appox.
t1.5
t0.059
)
13
(0.512
)
3
(0.118
)
14.5 0.571
7.5
0.295
22.5 37
0.886 1.457
M3 countersunk screw mounting hole
(for main body mounting)
M3 countersunk screw mounting hole
(for main body mounting)
(3 0.118)
(3 0.118)
(6 0.236)
21.5
0.846
(13 0.512)
7 0.276
6.5 0.256
23
0.906
5 0.197
t2
t0.079
2 0.079
18
0.709
30
1.181
2-ø4.5
ø0.177
t1.5
t0.059
t2
t0.079
Four bracket set
Four M3 (length 4 mm 0.157 in)
countersunk screws are attached.
28
SF4C
DIMENSIONS (Unit: mm in)
MS-SFC-4
The CAD data in the dimensions can be downloaded from our website.
Intermediate supporting bracket for versatile bracket (Optional)
43.5 1.713
27 1.063
(31 1.220)
27.3
1.075
(
13.6
0.535
10.5
0.413
)
9.7
0.382
t2
t0.079
8
0.315
6
0.236
6.5 0.256
6.5 0.256
27 1.063
37 1.457
Material: Stainless steel (SUS304)
Net weight: 40 g approx. (2 pcs.)
Package weight: 60 g appox.
10
0.394 20
25
0.787 0.984
3
( 0.118
)
Two bracket set
MS-SFCH-□
Metal protection case (Optional)
Assembly dimensions
Mounting drawing for the light curtains using the metal protection case
(MS-SFCH-□).
18
0.709
ø6.4 ø0.252 (M6 mounting hole)
(When using MS-SFC-2)
36.2
1.425
ø5.4 ø0.213
(M5 mounting hole)
19.6 0.772
(When using MS-SFC-1)
ø5.4 ø0.213
(M5 mounting hole)
(When using MS-SFC-1)
26
1.024
Display
section
10
0.394
3
43.5
0.118 1.713
E
96
90
3.543 3.780
43.5
1.713
6
0.236
8
0.315
F
26
1.024
D
C
B
A
5
0.197
5
0.197
D
A
26
1.024
ø5.4 ø0.213
(M5 mounting hole)
(When using MS-SFC-1)
19.6
0.772
ø6.4 ø0.252
(M6 mounting hole)
(When using MS-SFC-2)
18
0.709
ø5.4 ø0.213
(M5 mounting hole)
4-ø4.8 ø0.189
(M4 mounting hole)
(When using MS-SFC-2)
(When using MS-SFC-1)
36.2
1.425
t2.3 t0.091
Model No.
MS-SFCH-8
MS-SFCH-12
MS-SFCH-16
MS-SFCH-20
MS-SFCH-24
MS-SFCH-28
MS-SFCH-32
29
A
B
C
D
E
F
190
7.480
270
10.630
350
13.780
430
16.929
510
20.079
590
23.228
670
26.378
180
7.087
260
10.236
340
13.386
420
16.535
500
19.685
580
22.835
660
25.984
175
6.890
255
10.039
335
13.189
415
16.339
495
19.488
575
22.638
655
25.787
172
6.772
252
9.921
332
13.071
412
16.220
492
19.370
572
22.520
652
25.669
162
6.378
242
9.528
322
12.677
402
15.827
482
18.976
562
22.126
642
25.276
26
1.024
35
1.378
35
1.378
35
1.378
35
1.378
35
1.378
35
1.378
Net weight (2 pcs.)
Model No.
160 g approx.
MS-SFCH-8
240 g approx.
MS-SFCH-12
340 g approx.
MS-SFCH-16
420 g approx.
MS-SFCH-20
520 g approx.
MS-SFCH-24
600 g approx.
MS-SFCH-28
700 g approx.
MS-SFCH-32
A
D
190
7.480
270
10.630
350
13.780
430
16.929
510
20.079
590
23.228
670
26.378
172
6.772
252
9.921
332
13.071
412
16.220
492
19.370
572
22.520
652
25.669
SF4C
DIMENSIONS (Unit: mm in)
SFB-CC□-MU
The CAD data in the dimensions can be downloaded from our website.
Mating cable with connector on one end (Optional)
45
(1.772
)
SFB-CCJ□-MU
Mating cable with connectors on both ends (Optional)
45
(1.772
)
L
45
(1.772
)
L
ø15.6
ø0.614
ø15.6
ø0.614
ø15.6
ø0.614
ø6
ø0.236
ø6
ø0.236
• Length L
• Length L
Model No.
Model No.
Length L
Length L
SFB-CC3-MU
3,000 118.110
SFB-CCJ3D-MU
SFB-CC7-MU
7,000 275.590
SFB-CCJ3E-MU
10,000 393.700
SFB-CCJ10D-MU
SFB-CC10-MU
3,000 118.110
SFB-CCJ10E-MU
SFC-WY1
Y-shaped connector (Optional)
WY1-CC3
WY1-CC10
66
2.598
22.5
0.886
13.5
0.531
42
(1.654
)
41
1.614
Mating cable (Optional)
L
ø14
ø0.551
ø6
ø0.236
ø14
46.6 31
ø0.551 1.835 1.220
Model No.
ø9
ø0.354
Length L
WY1-CC3
3,000 118.110
WY1-CC10
SFC-HC
Handy-controller (Optional)
65
2.559
25.4
1.000
10,000 393.700
SF-C13
Control unit (Optional)
30
1.181
6.75
0.266
4
0.157
23
0.906
10,000 393.700
35
1.378
67.3
2.650
ø6 ø0.236 cables,
0.5 m 1.640 ft long
130
5.118
5
0.197
6
0.236
34.5
1.358
3 × 5 = 15
3 × 0.197 = 0.591
91.6
3.606
FUNCTION
140
5.512
CANCEL
ENTER
10
0.394
13.5
0.531
80
3.150
6.5
80.8
0.256
3.181
Suitable for 35 mm 1.378 in width DIN rail
5
0.197
13
0.512
22.5
0.886
30
Light curtain selection guide
Do you require
Type 4?
YES
NO
Is the protective height
640 mm 25.197 in or
YES
less?
NO
SF2B Ver.2
NO
640 mm 25.197 in
or more
Type2
• Definition of terms
Is the operating
range 3 m 9.843 ft YES
or less?
3 m 9.843 ft
or more
Protective height
SF4C
Min. sensing object
SF4B Ver.2
Operating range
Seamless structure for superior
environmental resistance
Seamless structure for superior
environmental resistance
Introduction to Panasonic Industrial Devices SUNX sensors that can be used as muting sensors
Compact Photoelectric Sensor
CX-400
SERIES
• World standard size
• 148 types for a wide variation
Ultra-slim Photoelectric Sensor
EX-10
SERIES
U-shaped Micro Photoelectric Sensor
PM-64
• 3.5 mm 0.138 in thickness
• Long sensing range: 1 m 3.281 ft
(thru-beam type: EX-19)
SERIES
• Extremely compact and space
saving
• A lineup of quick fitting-up
connector type
* The EX-20 series that is compatible with
M3 mounting screws is also available.
Rectangular-shaped Inductive Proximity Sensor
GX-F/H
SERIES
• Industry longest in stable
sensing range
• 10 times the durability
(Compared to previous models)
• IP68g protective construction
* Check the specifications for the muting sensors before making a selection. Refer to "PRECAUTIONS FOR PROPER USE" (P.21~) for details.
Please contact ..........
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Telephone: +81-568-33-7211
Facsimile: +81-568-33-2631
Global Sales Department
Telephone: +81-568-33-7861
Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global
All Rights Reserved ©
No. CE-SF4C-2-7 October, 2012
Specifications are subject to change without notice.
2012
PRINTED IN JAPAN