0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SFS4-SFD

SFS4-SFD

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SOCKET RELAY DIN MNT FOR 4P

  • 数据手册
  • 价格&库存
SFS4-SFD 数据手册
Safety Relays SF RERAYS Slim type Slim type Safety relay compliant with Safety standards FEATURES [Protective construction] Flux-resistant type ●●A  cquisition of Korean safety certification "S mark" Excluding with diode type ●●Forcibly guided contact structure 13 13 ●●S  lim profile: Length ( 40/50 mm ) × ● Width ( 13 mm ) × Height ( 24 mm ) 50 40 24 24 ●●Fast response time is achieved ( Max. 8 ms ) ●●W  ith diode and LED indication type available 4 poles ●●S  ockets and terminal sockets ( spade and ring tongue terminals compatible ) are available. 6 poles TYPICAL APPLICATIONS ●●Machine tools (Unit: mm) ●●Robots ●●Safety PLCs ●●C  ircuits with stringent safety standard requirements such as those in motor vehicle production equipment. ORDERING INFORMATION ( PART NO. ) AG 1 S Type S: Slim type Function 0: Standard (Without LED indication) 1: With LED indication 3: With diode and LED indication Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A 1 Form B 4: 4 Form A 2 Form B 5: 5 Form A 1 Form B 6: 3 Form A 3 Form B Rated coil voltage (DC) 1: 12 V, 2: 24 V, 3: 48 V Note) 1: Please consult us about other coil voltage. 2: LED indication color is green. ORDERING INFORMATION ( TYPE NO. ) SF S S: Slim type 2020.11 Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A 1 Form B 4: 4 Form A 2 Form B 5: 5 Form A 1 Form B 6: 3 Form A 3 Form B industrial.panasonic.com/ac/e/ Operation indication Nil: Without LED indication L : With LED indication Function Nil: None D : With diode Rated coil voltage DC 12, 24, 48 V ー1ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type TYPES ■■Standard ( without LED indication ) ●● PC board terminal: Carton packing Contact arrangement 2 Form A 2 Form B 4 poles 3 Form A 1 Form B 4 Form A 2 Form B 6 poles 5 Form A 1 Form B 3 Form A 3 Form B Rated coil voltage Type No. Part No. 12 V DC SFS2-DC12V AG1S021 24 V DC SFS2-DC24V AG1S022 ( E ) 48 V DC SFS2-DC48V AG1S023 12 V DC SFS3-DC12V AG1S031 24 V DC SFS3-DC24V AG1S032 ( E ) 48 V DC SFS3-DC48V AG1S033 12 V DC SFS4-DC12V AG1S041 24 V DC SFS4-DC24V AG1S042 ( E ) 48 V DC SFS4-DC48V AG1S043 12 V DC SFS5-DC12V AG1S051 24 V DC SFS5-DC24V AG1S052 ( E ) 48 V DC SFS5-DC48V AG1S053 12 V DC SFS6-DC12V AG1S061 24 V DC SFS6-DC24V AG1S062 ( E ) 48 V DC SFS6-DC48V AG1S063 Standard packing Inner carton Outer carton 50 pcs. 200 pcs. Note) F  or products in units of 10 pieces of inner carton, please add "E" to the end of the part number ( only applies to 24 V products ). The "E" part number suffix will appear only on the inner and outer cartons and not on the relay itself. ■■With LED indication ●● PC board terminal: Carton packing Contact arrangement 2 Form A 2 Form B 4 poles 3 Form A 1 Form B 4 Form A 2 Form B 6 poles 5 Form A 1 Form B 3 Form A 3 Form B Rated coil voltage Type No. Part No. 12 V DC SFS2-L-DC12V AG1S121 24 V DC SFS2-L-DC24V AG1S122 ( E ) 48 V DC SFS2-L-DC48V AG1S123 12 V DC SFS3-L-DC12V AG1S131 24 V DC SFS3-L-DC24V AG1S132 ( E ) 48 V DC SFS3-L-DC48V AG1S133 12 V DC SFS4-L-DC12V AG1S141 24 V DC SFS4-L-DC24V AG1S142 ( E ) 48 V DC SFS4-L-DC48V AG1S143 12 V DC SFS5-L-DC12V AG1S151 24 V DC SFS5-L-DC24V AG1S152 ( E ) 48 V DC SFS5-L-DC48V AG1S153 12 V DC SFS6-L-DC12V AG1S161 24 V DC SFS6-L-DC24V AG1S162 ( E ) 48 V DC SFS6-L-DC48V AG1S163 Standard packing Inner carton Outer carton 50 pcs. 200 pcs. Note) F  or products in units of 10 pieces of inner carton, please add "E" to the end of the part number ( only applies to 24 V products ). The "E" part number suffix will appear only on the inner and outer cartons and not on the relay itself. Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type ■■With LED indication: with diode type ●● PC board terminal: Carton packing Contact arrangement Rated coil voltage Type No. 12 V DC SFS2-L-DC12V-D AG1S321 24 V DC SFS2-L-DC24V-D AG1S322 ( E ) 48 V DC SFS2-L-DC48V-D AG1S323 12 V DC SFS3-L-DC12V-D AG1S331 24 V DC SFS3-L-DC24V-D AG1S332 ( E ) 48 V DC SFS3-L-DC48V-D AG1S333 12 V DC SFS4-L-DC12V-D AG1S341 24 V DC SFS4-L-DC24V-D AG1S342 ( E ) 48 V DC SFS4-L-DC48V-D AG1S343 12 V DC SFS5-L-DC12V-D AG1S351 24 V DC SFS5-L-DC24V-D AG1S352 ( E ) 48 V DC SFS5-L-DC48V-D AG1S353 12 V DC SFS6-L-DC12V-D AG1S361 24 V DC SFS6-L-DC24V-D AG1S362 ( E ) 48 V DC SFS6-L-DC48V-D AG1S363 2 Form A 2 Form B 4 poles 3 Form A 1 Form B 4 Form A 2 Form B 6 poles 5 Form A 1 Form B 3 Form A 3 Form B Standard packing Part No. Inner carton Outer carton 50 pcs. 200 pcs. Note) F  or products in units of 10 pieces of inner carton, please add "E" to the end of the part number ( only applies to 24 V products ). The "E" part number suffix will appear only on the inner and outer cartons and not on the relay itself. For sockets and terminal sockets, please read "SF RELAYS Slim type Sockets and DIN rail terminal sockets". RATING ■■Coil data • Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions or ambient temperature, etc. Therefore, please use the relay within ±5% of rated coil voltage. • "Initial" means the condition of products at the time of delivery. Contact arrangement 4 poles 2 Form A 2 Form B 3 Form A 1 Form B 4 Form A 2 Form B 6 poles 5 Form A 1 Form B 3 Form A 3 Form B Rated coil voltage Operate voltage* ( at 20℃ ) Release voltage* ( at 20℃ ) Rated operating current ( ±10%, at 20℃ ) Coil resistance ( ±10%, at 20℃ ) 12 V DC 30 mA 400 Ω 24 V DC 15 mA 1,600 Ω 48 V DC 7.5 mA 6,400 Ω 12 V DC 30 mA 400 Ω 24 V DC 15 mA 1,600 Ω 48 V DC 7.5 mA 6,400 Ω 12 V DC 24 V DC 48 V DC 12 V DC Max. 75% V of rated coil voltage ( Initial ) Min. 10% V of rated coil voltage ( Initial ) 41.7 mA 288 Ω 20.8 mA 1,152 Ω 10.4 mA 4,608 Ω 41.7 mA 288 Ω 24 V DC 20.8 mA 1,152 Ω 48 V DC 10.4 mA 4,608 Ω 12 V DC 41.7 mA 288 Ω 24 V DC 20.8 mA 1,152 Ω 48 V DC 10.4 mA 4,608 Ω Rated operating power Max. allowable voltage ( at 20℃ ) Approx. 360 mW 110% V of rated coil voltage Approx. 500 mW Note) For with LED indication, the rated operating current will increase by approximately 2 mA due to the LED display. * square, pulse drive ( JIS C 5442 ) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー3ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type ■■Specifications Characteristics Item Contact data 4 poles 2 Form A 2 Form B Contact resistance ( initial ) Max. 100 m Ω ( by voltage drop 6 V DC 1 A ) 3 Form A 1 Form B 4 Form A 2 Form B Contact material Au flashed AgSnO2 type Contact rating ( resistive ) 6 A 250 V AC, 6 A 30 V DC Max. switching power ( resistive ) 1,500 VA, 180 W Max. switching voltage 250 V AC, 125 V DC Max. switching current 6 A ( Reduce by 0.1 A/℃ for temperatures 70 to 85℃ ) Min. switching load ( reference value ) *1 1 mA 5 V DC Insulation resistance ( initial ) 5 Form A 1 Form B 3 Form A 3 Form B Min. 1,000 M Ω ( at 500 V DC, Measured portion is the same as the case of dielectric strength. ) Between open contacts Dielectric strength ( initial ) 6 poles Contact arrangement 1,500 Vrms for 1 min ( Detection current: 10 mA ) Between contact sets 7-8/9-10 between open contacts 2,500 Vrms for 1 min ( detection current: 10 mA ) 7-8/11-12 between open contacts 9-10/13-14 between open contacts 11-12/13-14 between open contacts 2,500 Vrms for 1 min ( detection current: 10 mA ) 3-4/5-6 between open contacts 3-4/7-8 between open contacts 5-6/9-10 between open contacts 4,000 Vrms for 1 min ( detection current: 10 mA ) 3-4/5-6 between open contacts 3-4/7-8 between open contacts 5-6/9-10 between open contacts 7-8/9-10 between open contacts 4,000 Vrms for 1 min ( detection current: 10 mA ) Between contact and coil 4,000 Vrms for 1 min ( detection current: 10 mA ) Time characteristics ( initial ) Operate time Max. 20 ms at rated coil voltage ( at 20℃ , without bounce ) Response time*2 Max. 8 ms at rated coil voltage ( at 20℃ , without bounce, without diode ) *4 Release time Max. 20 ms at rated coil voltage ( at 20℃ , without bounce ) Shock resistance Functional 200 m/s2 ( half-sine shock pulse: 11 ms, detection time: 10 µs ) Destructive 1,000 m/s2 ( half-sine shock pulse: 6 ms ) Vibration resistance Functional 10 to 55 Hz ( at double amplitude of 1.5 mm, detection time: 10 µs ) Destructive 10 to 55 Hz ( at double amplitude of 1.5 mm ) Expected life Mechanical life Min. 107 ( switching frequency: 180 times/min ) Conditions Conditions for usage, transport and storage*3 Ambient temperature: -40 to +85℃ Humidity: 5 to 85% RH ( Avoid icing and condensation ) *5 Unit weight Approx. 20 g Approx. 23 g *1. T  his value is a rough indication of the lower limit at which switching is possible at micro load level. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Response time is the time after the coil voltage turns off until the time when form A contact turns off. *3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. For details, please read "Ambient environment in GUIDELINES FOR RELAY USAGE". *4. Response time of with diode type is Max. 12 ms ( without bounce when rated coil voltage is applied ). *5. When the temperature is 70 to 85℃ , reduce the max. continuous carrying current by 0.1 A/℃ . ■■Electrical life Type 2 3 4 5 3 Form Form Form Form Form A A A A A 2 1 2 1 3 Form Form Form Form Form Load B B B B B Switching capacity Number of operations 6 A 250 V AC Min. 105 ( switching frequency 20 times/min ) 6 A 30 V DC Min. 105 ( switching frequency 20 times/min ) 1 A 250 V AC Min. 5 x 105 ( switching frequency 30 times/min ) 1 A 30 V DC Min. 5 x 105 ( switching frequency 30 times/min ) AC15: inductive load 2 A 240 V AC Min. 105 ( switching frequency 20 times/min , cos φ = 0.3 ) DC13: inductive load 1 A 24 V DC Min. 105 ( switching frequency 20 times/min , L/R = 48 ms ) Resistive load Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー4ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type REFERENCE DATA 1.Operate, response and release times 2.Coil temperature rise value Tested sample: SFS4-DC24V (4 Form A 2 Form B), 20pcs. (a contacts: 80, b contacts: 40) Z' Release time Response time 40 30 20 10 0 Tested sample: SFS4-DC24V (4 Form A 2 Form B), 3pcs. 50 Operate time Temperature rise, ℃ No. of contacts 50 3.Functional shock resistance Tested sample: SFS4-DC24 V (4 Form A 2 Form B), 3 pcs. Measured portion: Inside the coil Ambient temperature: Room temperature (27℃), 70℃, 85℃ 40 De-energized condition Energized condition X' Y 200m/s2 X 20 0 A Room temperature 6 A Room temperature 0 A 70℃ 6 A 70℃ 0 A 85℃ 4.5 A 85℃ 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Time, ms X Y' 30 0 90 Z Y 100 110 120 Coil applied voltage, %V Z 200m/s2 200m/s2 200m/s2 200m/s2 Z' X' 200m/s2 Y' 130 4.Max. switching capacity Contact current, A 10 8 7 AC resistive load 6 5 4 3 2 1 DC resistive load 0.7 0.5 0.3 0.2 0.1 10 20 30 50 70100 200 300 500 125 250 Contact voltage, V 1000 OTHER CONTACT GAPS WHEN CONTACTS ARE WELDED The table below shows the state of the other contacts when the current through the welded N.O. contact is 0 V and the rated voltage is applied through the welded N.C. contact. Sample: AG1S042 ( 4 Form A 2 Form B ) State of other contacts 3-4 ( N.C. ) 3-4 ( N.C. ) 7-8 ( N.O. ) > 0.5 > 0.5 > 0.5 > 0.5 − > 0.5 > 0.5 > 0.5 > 0.5 − − 5-6 ( N.C. ) Welded terminal No. 5-6 ( N.C. ) 7-8 ( N.O. ) > 0.5 > 0.5 9-10 ( N.O. ) > 0.5 > 0.5 11-12 ( N.O.) > 0.5 > 0.5 13-14 ( N.O. ) > 0.5 > 0.5 9-10 ( N.O. ) 11-12 ( N.O. ) 13-14 ( N.O. ) − − − >0.5: Contact gap Min. 0.5 mm Empty cells: Contact is ON or OFF state. Note) Contact gaps are shown at the initial state. If the contacts change state owing to load switching it is necessary to check the actual loading. Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type DIMENSIONS Unit: mm CAD The CAD data of the products with a "CAD" mark can be downloaded from our Website. ■■4 poles ( 2 Form A 2 Form B, 3 Form A 1 Form B ) External dimensions CAD Recommended PC board pattern ( BOTTOM VIEW ) Max.40 10.16 Max.13 10-1.4 dia. (1.83) 13.97 5.08 11.43 5.08 3.5 Max.24 Tolerance: ±0.1 1.83 1.0 0.50 10.16 13.97 General tolerance: ±0.3 Schematic ( BOTTOM VIEW ) Standard 2 Form A 2 Form B 1 3 4 7 8 With LED indication With diode and LED indication type 2 Form A 2 Form B 2 Form A 2 Form B 1 + 3 4 7 8 2 5 6 2 3 Form A 1 Form B 3 4 1 5 6 9 10 3 Form A 1 Form B 7 8 1 3 4 2 5 6 2 5 6 9 10 1 3 4 7 8 2 5 6 9 10 + - - 9 10 7 8 3 Form A 1 Form B 7 8 + - 3 4 - - 9 10 1 + + - + 5.08 11.43 5.08 2 5 6 9 10 ■■6 poles ( 4 Form A 2 Form B, 5 Form A 1 Form B, 3 Form A 3 Form B ) External dimensions CAD Recommended PC board pattern ( BOTTOM VIEW ) 10-1.4 dia. 10.16 Max.13 Max.50 (1.83) 13.97 5.08 11.43 5.08 5.08 5.08 3.5 Max.24 Tolerance: ±0.1 0.50 1.83 1.0 10.16 With LED indication 4 Form A 2 Form B 3 4 With diode and LED indication type 4 Form A 2 Form B 7 8 11 12 + 5.08 11.43 5.08 5.08 5.08 General tolerance: ±0.3 Schematic ( BOTTOM VIEW ) Standard 1 13.97 1 3 4 - 2 5 6 9 10 13 14 5 Form A 1 Form B 1 3 4 + 5 6 9 10 13 14 1 3 4 7 8 11 12 2 5 6 9 10 13 14 + - - 2 5 6 9 10 13 14 3 Form A 3 Form B 1 3 4 1 3 4 7 8 11 12 2 5 9 10 13 14 2 5 6 9 10 13 14 6 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 5 6 9 10 13 14 + 1 3 4 7 8 11 12 2 5 6 9 10 13 14 3 Form A 3 Form B + 1 3 4 7 8 11 12 2 5 6 9 10 13 14 - - - 2 - + + 7 8 11 12 5 Form A 1 Form B 3 Form A 3 Form B 7 8 11 12 3 4 - 2 5 Form A 1 Form B 7 8 11 12 1 + + - 4 Form A 2 Form B 7 8 11 12 ー6ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type SAFETY STANDARDS ■■UL/C-UL ( Recognized ) File No. E43149 ■■TÜV ( Certified ) Contact rating File No. Contact rating 6 A 277 V AC 6 A 250 V AC ( cos φ = 1.0 ) 6 A 30 V DC 6 A 30 V DC ( 0 ms ) B1803 13461 382 AC 15: 2 A 240 V AC ( cos φ = 0.3 ) DC 13: 1 A 24 V DC ( L/R 48 ms ) ■■CSA ( Certified ) ■■CQC ( Certified ) CSA standard certified by C-UL File No. Contact rating CQC10002044376 6 A 250 V AC GUIDELINES FOR USAGE ■■For cautions for use, please read "GUIDELINES FOR RELAY USAGE". https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp ■■For cautions for use SF relays slim type ●● Coil drive power supply Pure DC current should be applied to the coil. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The power wave form should be rectangular. ●● Connection of coil The positive ( + ) and negative ( - ) connections of polarized relay to the coil should be done as indicated on the schematic diagram. If connected incorrectly, it may malfunction or fail to operate. ●● Cleaning This relay is not sealed, therefore, whole washing may cause failure. Be careful that flux does not overflow onto the PC board or penetrate inside the relay. ●● Soldering When using automatic soldering, the following conditions are recommended ●● Conditions for usage, transport and storage 1 ) Temperature: -40 to +85℃ ( When the temperature is 70 to 85℃ , reduce the Max. 6 A. switching current by 0.1 A/℃ . ) 2 ) Humidity: 5 to 85% RH ( Avoid icing and condensation ) [Temperature and humidity range for usage, transport, and storage] 1 ) Preheating: 120℃ , within 120 sec 2 ) Soldering: 260 ±5℃ , within 6 sec ●● Please connect DC coil types with LED indication and with diode type correctly by verifying the coil polarity ● ( + ) ( - ). Connecting with reverse polarity will cause the LED not to light and damage the built-in diode due to its specification. Humidity (% RH) 85 Note: T  he humidity range varies with the temperature. Use within the range indicated in the graph. Allowable range 3 ) Air pressure: 86 to 106 kPa Avoid icing when used at temperatures lower than 0°C Avoid condensation when used at temperatures higher than 0°C 5 -40 0 Ambient temperature (℃) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー7ー Panasonic Corporation 2020 85 ASCTB119E 202011 Safety Relays SF RERAYS Slim type ●● Others handling precautions • Do not use relays that have been dropped, because doing so may be a cause of faulty operation. If the relay has been dropped, the appearance and characteristics should always be checked before use. • The expected life is specified under the standard test conditions in the JIS C 5442-1996 ( temperature 15 to 35℃ , humidity 25 to 75% RH ) Expected life is dependent on the coil driving circuit, load type, switching frequency, ambient environment and atmosphere. Check expected life under the actual condition. Also, be especially careful with loads such as those listed below. 1 ) When used for AC load switching and the switching phase is synchronous. Rocking and welding can easily occur due to contact shifting. 2 ) High frequency load switching During high frequency switching with certain loads, arcing may occur at the contacts. This can cause fusion to Oxygen and Nitrogen gas in the air creating Nitric Acid ( HNO3 ) which can cause corrosion to the metal material. Please see the following countermeasure examples: ( 1 ) Incorporate an arc-extinguishing circuit ( 2 ) Lower the switching frequency ( 3 ) Lower the humidity of ambient atmosphere • For secure operations, rated coil voltage should be applied to the coil. In addition, please note that operate and release voltages will vary according to the ambient temperature and operating conditions. • Abnormal heat, smoke, and/or fire may occur if the relay is used outside the allowable ranges for the coil ratings, contact ratings, expected life and other specifications. • Incorrect wiring may cause unexpected malfunction, abnormal heat or fire. • Check the ambient atmosphere when storing or transporting the relays and devices containing the relays. Icing or condensation may occur in the relay causing damage. Avoid exposing the relays to heavy loads, or strong shock and vibration. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー8ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type SF RELAYS Slim type Sockets/DIN rail terminal sockets TYPES ■■Sockets Type PC board sockets Number of poles Type No. Part No. For 4 poles SFS4-PS AG1S844 For 6 poles SFS6-PS AG1S864 Standard packing Inner carton Outer carton 10 pcs. 100 pcs. ■■DIN rail terminal socket Type Number of poles Type No. Part No. Terminal sockets for spade and ring tongue terminals For 4 poles SFS4-SFD-R AG1S848 For 6 poles SFS6-SFD-R AG1S868 Standard packing Inner carton Outer carton 10 pcs. 100 pcs. Note) Spade tongue terminal dedicated terminal sockets, please order AG1S847 for 4 poles and AG1S867 for 6 poles. RATING ■■Specifications Item Specifications Dielectric strength ( initial ) Between each terminal 2,500 V AC for 1 min ( detection current: 10 mA ) Insulation resistance ( initial ) Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. ) Max. continuous carrying current 6 A ( Reduce by 0.1 A/℃ for temperatures 70 to 85℃ ) Conditions for usage, transport and storage Ambient temperature: -40 to 85℃ , Humidity 5 to 85% RH ( Avoid icing and condensation ) DIMENSIONS Unit: mm CAD The CAD data of the products with a "CAD" mark can be downloaded from our Website. ■■PC board sockets ●● For 4 poles: AG1S844 External dimensions CAD Recommended PC board pattern ( BOTTOM VIEW ) 15.0 50.0 40.0 10.16 4.1 0.8 (13) 10.16 (6.93) 13.97 11.43 5.08 0.4 3-3.2 dia. (For M3 screw) Please use the screw with a stem length of 8 mm 39.9 (6.93) 24.8 10-1.1 dia. 13.97 5.08 5.08 11.43 Tolerance: ±0.1 (13) 5.08 General tolerance: ±0.3 Schematic ( BOTTOM VIEW ) Standard 2 Form A 2 Form B mounted 1 3 4 With diode and LED indication type 2 Form A 2 Form B mounted 2 Form A 2 Form B mounted 1 7 8 + 3 4 7 8 2 5 6 9 10 3 Form A 1 Form B mounted 1 3 4 2 5 6 9 10 3 Form A 1 Form B mounted 1 3 4 2 5 6 9 10 2 5 6 9 10 1 3 4 7 8 2 5 6 9 10 + - - 2 5 6 9 10 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 7 8 3 Form A 1 Form B mounted 7 8 + - 3 4 - - 7 8 1 + + - + With LED indication ー9ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type ●● For 6 poles: AG1S864 External dimensions CAD Recommended PC board pattern ( BOTTOM VIEW ) 15.0 60.0 49.9 40.0 10.16 4.1 0.8 Please use the screw with a stem length of 8 mm 14-1.1 dia. 13.97 5.08 5.08 5.08 5.08 11.43 Tolerance: ±0.1 (13) (13) (6.93) 10.16 (6.93) 24.8 3-3.2 dia. (For M3 screw) 13.97 5.08 0.4 11.43 5.08 5.08 5.08 General tolerance: ±0.3 Schematic ( BOTTOM VIEW ) Standard With LED indication With diode and LED indication type 4 Form A 2 Form B mounted 4 Form A 2 Form B mounted 4 Form A 2 Form B mounted 1 3 4 7 8 11 12 + 1 3 4 7 8 11 12 - - 2 5 6 9 10 13 14 5 Form A 1 Form B mounted 1 3 4 + 5 6 9 10 13 14 1 3 4 7 8 11 12 2 5 6 9 10 13 14 + - - 2 5 6 9 10 13 14 3 Form A 3 Form B mounted 1 3 4 1 3 4 7 8 11 12 2 5 9 10 13 14 + + 2 5 6 9 10 13 14 6 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 2 5 6 9 10 13 14 5 Form A 1 Form B mounted + 1 3 4 7 8 11 12 2 5 6 9 10 13 14 3 Form A 3 Form B mounted + 1 3 4 7 8 11 12 2 5 6 9 10 13 14 - - - 7 8 11 12 - 3 Form A 3 Form B mounted 7 8 11 12 3 4 - 2 5 Form A 1 Form B mounted 7 8 11 12 1 + + ー 10 ー Panasonic Corporation 2020 ASCTB119E 202011 Safety Relays SF RERAYS Slim type ■■Terminal socket for spade and ring tongue terminals ( finger protect type ) ●● For 4 poles: AG1S848 External dimensions Mounting hole pattern 6.5 R2.0 M3 screw 2-M3.5 or 4 dia. hole 75.0 14.5±0.2 6.5 6.2±0.3 dia. 80.0±0.2 CAD 2-4×5 hole Tolerance: ±0.1 6.3+0.3  0 62.4* 58.9 Schematic ( TOP VIEW ) 10 7 8 2 1 9 6 4.0 35.4 22.4 5 General tolerance: ±0.5 4 * Reference value (when using DIN rail ATA48011) Note) Ring tongue terminals cannot be used AG1S847. In use of a ring tongue terminals, please use AG1S848. 3 ●● For 6 poles: AG1S868 Mounting hole pattern 6.5 External dimensions R2.0 M3 screw 75.0 22.0±0.2 2-4×5 hole 6.5 6.2±0.3 dia. Tolerance: ±0.1 6.3 +0.3  0 Schematic ( TOP VIEW ) 35.4 4.0 58.9 62.4* 2-M3.5 or 4 dia. hole 80.0±0.2 CAD 29.8 General tolerance: ±0.5 14 12 13 11 10 8 9 7 6 4 * Reference value (when us㏌g DIN rail ATA48011) Note) Ring tongue terminals cannot be used AG1S867. In use of a ring tongue terminals, please use AG1S868. Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 11 ー 5 2 Panasonic Corporation 2020 1 3 ASCTB119E 202011 Safety Relays SF RERAYS Slim type SAFETY STANDARDS ■■UL/C-UL ( Recognized ) ■■TÜV ( Certified ) File No. File No. E148103 B 013461 0318 Rev.01 GUIDELINES FOR USAGE ■■Installation on DIN rail 2 ) Refer to the figure for applicable solderless terminals. Spade tongue terminal 1 ) Attach directly to the chassis or use a DIN rail. ( 1 ) When attaching directly to chassis • Use a M3.5 screw, spring washer, and hex nut. • For the mounting pitch, refer to the dimensions. ( 2 ) When installing on a DIN rail • Use a 35 mm wide DIN rail ( DIN46277 ). • Install and remove as shown in the figures. < When installing > Max. 6.3 mm Min. 3 mm Ring tongue terminal Max. 6.3 mm Min. 3 mm Push DIN rail < When removing > Pull Screwdriver DIN rail Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 12 ー Panasonic Corporation 2020 ASCTB119E 202011 GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp Precautions for Coil Input Long term current carrying A circuit that will be carrying a current continuously for long periods without relay switching operation. (circuits for emergency lamps, alarm devices and error inspection that, for example, revert only during malfunction and output warnings with form B contacts) Continuous, long-term current to the coil will facilitate deterioration of coil insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type latching relay. If you need to use a single stable relay, use a sealed type relay that is not easily affected by ambient conditions and make a failsafe circuit design that considers the possibility of contact failure or disconnection. DC Coil operating power Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, please check with the actual circuit since the electrical characteristics may vary. The rated coil voltage should be applied to the coil and the set/reset pulse time of latching type relay differs for each relays, please refer to the relay's individual specifications. Maximum allowable voltage and temperature rise Proper usage requires that the rated coil voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum continuous voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog. Operate voltage change due to coil temperature rise In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the pick-up voltage will become somewhat higher. Also, it will be the same as using it in a higher temperature atmosphere. The resistance/temperature relationship for copper wire is about 0.4% for 1°C, and with this ratio the coil resistance increases. That is, in order to operate of the relay, it is necessary that the voltage be higher than the pick-up voltage and the pick-up voltage rises in accordance with the increase in the resistance value. However, for some polarized relays, this rate of change is considerably smaller. Coil connection When connecting coils of polarized relays, please check coil polarity (+,-) at the internal connection diagram (Schematic). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and so on, and circuit do not work. Avoid impressing voltages to the set coil and reset coil at the same time. Ambient Environment Usage, Transport, and Storage Conditions Dew condensation Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation causes the failures like insulation deterioration, wire disconnection and rust etc. Panasonic Corporation does not guarantee the failures caused by condensation. The heat conduction by the equipment may accelerate the cooling of device itself, and the condensation may occur. Please conduct product evaluations in the worst condition of the actual usage. (Special attention should be paid when high temperature heating parts are close to the device. Also please consider the condensation may occur inside of the device.) Icing Condensation or other moisture may freeze on relays when the temperature become lower than 0°C.This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Corporation does not guarantee the failures caused by the icing. The heat conduction by the equipment may accelerate the cooling of relay itself and the icing may occur. Please conduct product evaluations in the worst condition of the actual usage. Low temperature and low humidity The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. High temperature and high humidity Storage for extended periods of time (including transportation periods) at high temperature or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/ or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. During usage, storage, or transportation, avoid locations subjected to direct sunlight and maintain normal temperature, humidity and pressure conditions. Temperature/Humidity/Pressure When transporting or storing relays while they are tube packaged, there are cases the temperature may differ from the allowable range. In this case be sure to check the individual specifications. Also allowable humidity level is influenced by temperature, please check charts shown below and use relays within mentioned conditions. (Allowable temperature values differ for each relays, please refer to the relay's individual specifications.) 1) Temperature: The tolerance temperature range differs for each relays, please refer to the relay’s individual specifications 2) Humidity: 5 to 85 % RH 3) Pressure: 86 to 106 kPa Humidity(%RH) 85 Allowable range Avoid icing when used at temperatures lower than 0°C Avoid condensation when used at temperatures higher than 0°C 5 0 -40 Ambient temperature(℃) 85 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 13 ー Panasonic Corporation 2019 ASCTB412E 201911 GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE Package In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. Silicon When a source of silicone substances (silicone rubber, silicone oil, silicone coating materials and silicone filling materials etc.) is used around the relay, the silicone gas (low molecular siloxane etc.) may be produced. This silicone gas may penetrate into the inside of the relay. When the relay is kept and used in this condition, silicone compound may adhere to the relay contacts which may cause the contact failure. Do not use any sources of silicone gas around the relay (Including plastic seal types). NOx Generation When relay is used in an atmosphere high in humidity to switch a load which easily produces an arc, the NOx created by the arc and the water absorbed from outside the relay combine to produce nitric acid. This corrodes the internal metal parts and adversely affects operation. Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use at high humidity is unavoidable, please contact our sales representative. Others Cleaning • Although the environmentally sealed type relay (plastic sealed type, etc.) can be cleaned, avoid immersing the relay into cold liquid (such as cleaning solvent) immediately after soldering. Doing so may deteriorate the sealing performance. • Cleaning with the boiling method is recommended(The temperature of cleaning liquid should be 40°C or lower ). Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may cause breaks in the coil or slight sticking of the contacts due to ultrasonic energy. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 14 ー Panasonic Corporation 2019 ASCTB412E 201911 Please contact .......... Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industral.panasonic.com/ac/e/ ©Panasonic Corporation 2020 ASCTB119E 202011 Specifications are subject to change without notice.
SFS4-SFD 价格&库存

很抱歉,暂时无法提供与“SFS4-SFD”相匹配的价格&库存,您可以联系我们找货

免费人工找货