Safety Relays
SF RELAYS Slim type
Product Catalog
2024.6
Safety Relays
SF RELAYS Slim type
Slim type Safety relay compliant with Safety standards
FEATURES
Protective construction: Flux-resistant type
● Acquisition of Korean safety certification "S mark"
Excluding with diode type
● Forcibly guided contact structure
13
13
● Slim profile:
Width ( 13 mm ) × Length ( 40/50 mm ) × Height ( 24 mm )
50
40
24
24
● Fast response time is achieved ( Max. 8 ms )
● With diode and LED indication type available
4 poles
● Sockets and terminal sockets ( spade and ring
tongue terminals compatible ) are available.
6 poles
TYPICAL APPLICATIONS
( Unit: mm )
● Machine tools
● Robots
● Safety PLCs
● Circuits with stringent safety standard
requirements such as those in motor vehicle
production equipment.
ORDERING INFORMATION ( PART NO. : Ordering part number for Japanese market)
AG 1 S
Type
S: Slim type
Function
0: Standard (Without LED indication)
1: With LED indication
3: With diode and LED indication
Contact arrangement
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A 2 Form B
5: 5 Form A 1 Form B
6: 3 Form A 3 Form B
Rated coil voltage (DC)
1: 12 V
2: 24 V
3: 48 V
7: 18 V
8: 21 V
Notes) 1: Please consult us about other coil voltage.
2: LED indication color is green.
ORDERING INFORMATION ( TYPE NO. : Ordering part number for non Japanese market)
SF S
S: Slim type
Contact arrangement
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A 2 Form B
5: 5 Form A 1 Form B
6: 3 Form A 3 Form B
Operation indication
Nil: Without LED indication
L : With LED indication
Function
Nil: None
D : With diode
Rated coil voltage
DC 12, 18, 21, 24, 48 V
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー1ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
TYPES
" Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market.
■ Standard ( without LED indication )
● PC board terminal: Carton packing
Standard packing
Contact arrangement
2 Form A 2 Form B
4 poles
3 Form A 1 Form B
4 Form A 2 Form B
6 poles
5 Form A 1 Form B
3 Form A 3 Form B
Rated coil voltage
Type No.
Part No.
12 V DC
SFS2-DC12V
AG1S021
18 V DC
SFS2-DC18V
AG1S027
21 V DC
SFS2-DC21V
AG1S028
24 V DC
SFS2-DC24V
AG1S022
48 V DC
SFS2-DC48V
AG1S023
12 V DC
SFS3-DC12V
AG1S031
18 V DC
SFS3-DC18V
AG1S037
21 V DC
SFS3-DC21V
AG1S038
24 V DC
SFS3-DC24V
AG1S032
48 V DC
SFS3-DC48V
AG1S033
12 V DC
SFS4-DC12V
AG1S041
18 V DC
SFS4-DC18V
AG1S047
21 V DC
SFS4-DC21V
AG1S048
24 V DC
SFS4-DC24V
AG1S042
48 V DC
SFS4-DC48V
AG1S043
12 V DC
SFS5-DC12V
AG1S051
18 V DC
SFS5-DC18V
AG1S057
21 V DC
SFS5-DC21V
AG1S058
24 V DC
SFS5-DC24V
AG1S052
48 V DC
SFS5-DC48V
AG1S053
12 V DC
SFS6-DC12V
AG1S061
18 V DC
SFS6-DC18V
AG1S067
21 V DC
SFS6-DC21V
AG1S068
24 V DC
SFS6-DC24V
AG1S062
48 V DC
SFS6-DC48V
AG1S063
Rated coil voltage
Type No.
Part No.
12 V DC
SFS2-L-DC12V
AG1S121
24 V DC
SFS2-L-DC24V
AG1S122
48 V DC
SFS2-L-DC48V
AG1S123
12 V DC
SFS3-L-DC12V
AG1S131
24 V DC
SFS3-L-DC24V
AG1S132
48 V DC
SFS3-L-DC48V
AG1S133
12 V DC
SFS4-L-DC12V
AG1S141
24 V DC
SFS4-L-DC24V
AG1S142
48 V DC
SFS4-L-DC48V
AG1S143
12 V DC
SFS5-L-DC12V
AG1S151
24 V DC
SFS5-L-DC24V
AG1S152
48 V DC
SFS5-L-DC48V
AG1S153
12 V DC
SFS6-L-DC12V
AG1S161
24 V DC
SFS6-L-DC24V
AG1S162
48 V DC
SFS6-L-DC48V
AG1S163
Inner carton
Outer
carton
50 pcs.
200 pcs.
■ With LED indication
● PC board terminal: Carton packing
Standard packing
Contact arrangement
2 Form A 2 Form B
4 poles
3 Form A 1 Form B
4 Form A 2 Form B
6 poles
5 Form A 1 Form B
3 Form A 3 Form B
Inner carton
Outer
carton
50 pcs.
200 pcs.
Note) For 18 V and 21 V, please inquire our sales representative.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー2ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
■ With LED indication: with diode type
● PC board terminal: Carton packing
Standard packing
Contact arrangement
Rated coil voltage
Type No.
Part No.
12 V DC
SFS2-L-DC12V-D
AG1S321
24 V DC
SFS2-L-DC24V-D
AG1S322
48 V DC
SFS2-L-DC48V-D
AG1S323
2 Form A 2 Form B
4 poles
3 Form A 1 Form B
4 Form A 2 Form B
6 poles
5 Form A 1 Form B
3 Form A 3 Form B
12 V DC
SFS3-L-DC12V-D
AG1S331
24 V DC
SFS3-L-DC24V-D
AG1S332
48 V DC
SFS3-L-DC48V-D
AG1S333
12 V DC
SFS4-L-DC12V-D
AG1S341
24 V DC
SFS4-L-DC24V-D
AG1S342
48 V DC
SFS4-L-DC48V-D
AG1S343
12 V DC
SFS5-L-DC12V-D
AG1S351
24 V DC
SFS5-L-DC24V-D
AG1S352
48 V DC
SFS5-L-DC48V-D
AG1S353
12 V DC
SFS6-L-DC12V-D
AG1S361
24 V DC
SFS6-L-DC24V-D
AG1S362
48 V DC
SFS6-L-DC48V-D
AG1S363
Inner carton
Outer
carton
50 pcs.
200 pcs.
Notes) For sockets and terminal sockets, please read " SF RELAYS Slim type Sockets and DIN rail terminal sockets " .
For 18 V and 21 V, please inquire our sales representative.
RATING
■ Coil data
• Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• "Initial" means the condition of products at the time of delivery.
Contact
arrangement
2 Form A
2 Form B
Operate voltage*
( at 20℃ )
Release voltage*
( at 20℃ )
3 Form A
1 Form B
4 Form A
2 Form B
5 Form A
1 Form B
3 Form A
3 Form B
Rated operating
current
( ±10%, at 20℃ )
Coil resistance
( ±10%, at 20℃ )
12 V DC
30
mA
18 V DC
20
mA
900 Ω
21 V DC
17.1 mA
1,225 Ω
24 V DC
15
1,600 Ω
48 V DC
4
poles
6
poles
Rated coil
voltage
mA
7.5 mA
6,400 Ω
30
mA
18 V DC
20
mA
900 Ω
21 V DC
17.1 mA
1,225 Ω
24 V DC
400 Ω
15
1,600 Ω
48 V DC
7.5 mA
12 V DC
41.7 mA
288 Ω
27.8 mA
648 Ω
23.8 mA
882 Ω
18 V DC
21 V DC
24 V DC
Max. 75% V
of rated coil
voltage
( Initial )
Min. 10% V
of rated coil
voltage
( Initial )
Max. allowable
voltage
( at 20℃ )
400 Ω
12 V DC
mA
Rated
operating
power
Approx. 360 mW
6,400 Ω
20.8 mA
1,152 Ω
48 V DC
10.4 mA
4,608 Ω
12 V DC
41.7 mA
288 Ω
18 V DC
27.8 mA
648 Ω
21 V DC
23.8 mA
882 Ω
24 V DC
20.8 mA
1,152 Ω
4,608 Ω
48 V DC
10.4 mA
12 V DC
41.7 mA
288 Ω
18 V DC
27.8 mA
648 Ω
21 V DC
23.8 mA
882 Ω
24 V DC
20.8 mA
1,152 Ω
48 V DC
10.4 mA
4,608 Ω
110% V of
rated coil
voltage
Approx. 500 mW
Note) For with LED indication, the rated operating current will increase by approximately 2 mA due to the LED display.
* square, pulse drive ( JIS C 5442 )
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー3ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
■ Specifications
Characteristics
Item
Contact data
4 poles
2 Form A 2 Form B
Contact resistance
( initial )
Max. 100 mΩ ( by voltage drop 6 V DC 1 A )
Contact material
Au flashed AgSnO2 type
Contact rating
( resistive )
6 A 250 V AC, 6 A 30 V DC
Max. switching
power ( resistive )
1,500 VA, 180 W
Max. switching
voltage
250 V AC, 125 V DC
Max. switching
current
6 A ( Reduce by 0.1 A/℃ for temperatures 70 to 85℃ )
Min. switching load
( reference value ) *1
1 mA 5 V DC
Insulation resistance ( initial )
3 Form A 1 Form B
4 Form A 2 Form B
5 Form A 1 Form B
3 Form A 3 Form B
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
Between open
contacts
Dielectric
strength
( initial )
6 poles
Contact arrangement
1,500 Vrms for 1 min ( Detection current: 10 mA )
Between contact sets
7-8/9-10 between open contacts
2,500 Vrms for 1 min
( detection current: 10 mA )
7-8/11-12 between open contacts
9-10/13-14 between open contacts
11-12/13-14 between open contacts
2,500 Vrms for 1 min ( detection current: 10 mA )
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
4,000 Vrms for 1 min
( detection current: 10 mA )
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
7-8/9-10 between open contacts
4,000 Vrms for 1 min ( detection current: 10 mA )
Between contact and
coil
4,000 Vrms for 1 min ( detection current: 10 mA )
Time
characteristics
( initial )
Operate time
Max. 20 ms at rated coil voltage ( at 20℃, without bounce )
Response time*2
Max. 8 ms at rated coil voltage ( at 20℃, without bounce, without diode ) *4
Release time
Max. 20 ms at rated coil voltage ( at 20℃, without bounce )
Shock
resistance
Functional
200 m/s2 ( half-sine shock pulse: 11 ms, detection time: 10 µs )
Destructive
1,000 m/s2 ( half-sine shock pulse: 6 ms )
Vibration
resistance
Functional
10 to 55 Hz ( at double amplitude of 1.5 mm, detection time: 10 µs )
Destructive
10 to 55 Hz ( at double amplitude of 1.5 mm )
Expected life
Mechanical life
Min. 10 x 106 ope. ( switching frequency: at 180 times/min )
Conditions
Conditions for usage,
transport and
storage*3
Ambient temperature: -40 to +85℃
Humidity: 5 to 85% RH ( Avoid icing and condensation ) *5
Unit weight
Approx. 20 g
Approx. 23 g
*1. This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Response time is the time after the coil voltage turns off until the time when form A contact turns off.
*3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. For details, please read "Ambient
environment in GUIDELINES FOR RELAY USAGE".
*4. Response time of with diode type is Max. 12 ms ( without bounce when rated coil voltage is applied ).
*5. When the temperature is 70 to 85℃, reduce the max. continuous carrying current by 0.1 A/℃.
■ Electrical life
Type
2
3
4
5
3
Form
Form
Form
Form
Form
A
A
A
A
A
2
1
2
1
3
Form
Form
Form
Form
Form
Load
B
B
B
B
B
Switching capacity
Number of operations
6 A 250 V AC
Min. 100 x 103 ope.
( switching frequency at 20 times/min )
6 A 30 V DC
Min. 100 x 103 ope.
( switching frequency at 20 times/min )
1 A 250 V AC
Min. 500 x 103 ope.
( switching frequency at 30 times/min )
1 A 30 V DC
Min. 500 x 103 ope.
( switching frequency at 30 times/min )
AC15: inductive load
2 A 240 V AC
Min. 100 x 103 ope.
( switching frequency at 20 times/min , cosφ = 0.3 )
DC13: inductive load
1 A 24 V DC
Min. 100 x 103 ope.
( switching frequency at 20 times/min , L/R = 48 ms )
Resistive load
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー4ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
REFERENCE DATA
1.Operate, response and release times
2.Coil temperature rise value
Tested sample: SFS4-DC24V (4 Form A 2 Form B),
20pcs. (a contacts: 80, b contacts: 40)
Tested sample: SFS4-DC24 V (4 Form A 2 Form B),
3 pcs.
Measured portion: Inside the coil
Ambient temperature: Room temperature (27℃),
70℃, 85℃
50
X
20
10
40
Y
200m/s2
Y'
X
30
20
0 A Room temperature
6 A Room temperature
0 A 70℃
6 A 70℃
0 A 85℃
4.5 A 85℃
10
0
90
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Time, ms
De-energized condition
Energized condition
X'
Y
Temperature rise, ℃
No. of contacts
Z
Z'
Release time
Response time
30
0
Tested sample: SFS4-DC24V (4 Form A 2 Form B),
3pcs.
50
Operate time
40
3.Functional shock resistance
100
110
120
Coil applied voltage, %V
Z
200m/s2
200m/s2
200m/s2
200m/s2
Z'
X'
200m/s2
Y'
130
4.Max. switching capacity
Contact current, A
10
8
7
AC resistive load
6
5
4
3
2
DC resistive load
1
0.7
0.5
0.3
0.2
0.1
10
20 30
50 70100 200 300 500
125 250
Contact voltage, V
1000
OTHER CONTACT GAPS WHEN CONTACTS ARE WELDED
The table below shows the state of the other contacts when the current through the welded N.O. contact is 0 V and the rated
voltage is applied through the welded N.C. contact.
Sample: AG1S042 ( 4 Form A 2 Form B )
State of other contacts
3-4 ( N.C. )
3-4 ( N.C. )
−
5-6 ( N.C. )
Welded terminal No.
7-8 ( N.O. )
5-6 ( N.C. )
> 0.5
7-8 ( N.O. )
9-10 ( N.O. )
11-12 ( N.O. )
13-14 ( N.O. )
> 0.5
> 0.5
> 0.5
> 0.5
−
> 0.5
> 0.5
> 0.5
> 0.5
> 0.5
−
9-10 ( N.O. )
> 0.5
> 0.5
11-12 ( N.O.)
> 0.5
> 0.5
13-14 ( N.O. )
> 0.5
> 0.5
−
−
−
>0.5: Contact gap Min. 0.5 mm
Empty cells: Contact is ON or OFF state.
Note) Contact gaps are shown at the initial state. If the contacts change state owing to load switching it is necessary to check the actual loading.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー5ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
CAD The CAD data of the products with a "CAD" mark can be downloaded from our Website.
DIMENSIONS
Unit: mm
■ 4 poles ( 2 Form A 2 Form B, 3 Form A 1 Form B )
CAD
External dimensions
Recommended PC board pattern
( BOTTOM VIEW )
Max.13
Max.40
10.16
10-φ1.4
(1.83)
13.97
5.08
11.43 5.08
3.5
Max.24
Tolerance: ±0.1
1.83
1.0
0.50
10.16
13.97
General tolerance: ±0.3
Schematic ( BOTTOM VIEW )
Standard
2 Form A 2 Form B
1
3 4
5.08 11.43 5.08
With LED indication
With diode and
LED indication type
2 Form A 2 Form B
2 Form A 2 Form B
7 8
1
+
3 4
7 8
−
5 6
9 10
2
3 Form A 1 Form B
3 4
1
5 6
9 10
3 Form A 1 Form B
7 8
1
+
3
4
5 6
9 10
2
5 6
9 10
3 Form A 1 Form B
1
3 4
7 8
2
5 6
9 10
+
−
−
2
7 8
7 8
+
−
3 4
−
−
2
1
+
+
2
5 6
9 10
■ 6 poles ( 4 Form A 2 Form B, 5 Form A 1 Form B, 3 Form A 3 Form B )
CAD
External dimensions
Recommended PC board pattern
( BOTTOM VIEW )
Max.13
Max.50
10.16
14-φ1.4
(1.83)
13.97
5.08
11.43 5.08 5.08 5.08
3.5
Max.24
Tolerance: ±0.1
0.50
1.83
1.0
10.16
With LED indication
4 Form A 2 Form B
3 4
1
3
4
4 Form A 2 Form B
7 8 11 12
5 6
2
9 10 13 14
5 Form A 1 Form B
1
3 4
+
5 6
9 10 13 14
5 Form A 1 Form B
7 8 11 12
1
3 4
5
6
3 Form A 3 Form B
1
3 4
5 6
9 10 13 14
3 Form A 3 Form B
7 8 11 12
1
3 4
2
5 6
9 10 13 14
1
3 4
7 8 11 12
2
5 6
9 10 13 14
1
3 4
7 8 11 12
2
5 6
9 10 13 14
+
−
−
−
9 10 13 14
3 Form A 3 Form B
7 8 11 12
+
+
5 6
−
2
9 10 13 14
2
+
−
2
7 8 11 12
5 Form A 1 Form B
7 8 11 12
+
−
3 4
−
−
2
1
+
+
−
With diode and
LED indication type
4 Form A 2 Form B
7 8 11 12
+
5.08 11.43 5.08 5.08 5.08
General tolerance: ±0.3
Schematic ( BOTTOM VIEW )
Standard
1
13.97
2
5
6
9 10 13 14
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー6ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ UL/C-UL ( Approved )
File No.
E43149
■ TÜV ( Approved )
Contact rating
File No.
Contact rating
6 A 250 V AC ( cosφ = 1.0 )
6 A 277 V AC
6 A 30 V DC
B 013461 0711 Rev.02
6 A 30 V DC ( 0 ms )
AC 15: 2 A 240 V AC ( cosφ = 0.3 )
DC 13: 1 A 24 V DC ( L/R 48 ms )
■ CSA ( Approved )
■ CQC ( Approved )
CSA standard approved by C-UL
File No.
Contact rating
CQC10002044376
6 A 250 V AC
( switching
frequency at 20
times/min )
Operations
Temp.
10 × 103
−40 to +70 ℃
• Type of insulation ( Between contact and coil ) : Basic insulation
• Pollution degree
:2
•
•
•
•
Impulse withstand voltage
: 2,500 V
Rated insulation voltage
: 250 V
Category of environmental protection : RTⅡ
Type of interruption ( Between open contacts ) : Micro disconnection
•
•
•
•
Mounting distance
Duty factor
Test procedure
: 10 mm
: 50 %
:A
Number of cycles for mechanical endurance: 106
Note) The following products are not CQC compliant.
( Please check our website for details )
AG1S3**, Coil voltage: 18 V and 21 V product, Part number suffix " E "
GUIDELINES FOR USAGE
■ For cautions for use, please read "GUIDELINES FOR RELAY USAGE".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
■ For cautions for use SF relays slim type
● Coil drive power supply
Pure DC current should be applied to the coil. If it includes
ripple, the ripple factor should be less than 5%. However,
check it with the actual circuit since the characteristics
may be slightly different. The power wave form should be
rectangular.
● Connection of coil
The positive ( + ) and negative ( - ) connections of
polarized relay to the coil should be done as indicated on
the schematic diagram. If connected incorrectly, it may
malfunction or fail to operate.
● Cleaning
This relay is not sealed, therefore, whole washing may
cause failure. Be careful that flux does not overflow onto
the PC board or penetrate inside the relay.
● Soldering
When using automatic soldering, the following conditions
are recommended
1 ) Preheating: 120℃, within 120 sec
2 ) Soldering: 260 5℃, within 6 sec
● Please connect DC coil types with LED indication and
with diode type correctly by verifying the coil polarity
( + ) ( - ).
Connecting with reverse polarity will cause the LED
not to light and damage the built-in diode due to its
specification.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー7ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
[Temperature and humidity range for usage,
● Conditions for usage, transport and storage
transport, and storage]
1 ) Temperature: -40 to +85℃
( When the temperature is 70 to 85℃, reduce the
Humidity (% RH)
Max. 6 A. switching current by 0.1 A/℃. )
2 ) Humidity: 5 to 85% RH
( Avoid icing and condensation )
85
Note) The humidity range varies with the temperature. Use within the
range indicated in the graph.
Allowable range
3 ) Air pressure: 86 to 106 kPa
Avoid icing
when used at
temperatures
lower than 0°C
Avoid condensation when
used at temperatures higher
than 0°C
5
-40
0
85
Ambient temperature (℃)
● Others handling precautions
• Do not use relays that have been dropped, because
doing so may be a cause of faulty operation. If the relay
has been dropped, the appearance and characteristics
should always be checked before use.
• The expected life is specified under the standard test
conditions in the JIS C 5442-1996 ( temperature 15 to
35℃, humidity 25 to 75% RH )
Expected life is dependent on the coil driving circuit,
load type, switching frequency, ambient environment
and atmosphere. Check expected life under the actual
condition. Also, be especially careful with loads such as
those listed below.
1 ) When used for AC load switching and the switching
phase is synchronous.
Rocking and welding can easily occur due to contact
shifting.
2 ) High frequency load switching
During high frequency switching with certain
loads, arcing may occur at the contacts. This can
cause fusion to Oxygen and Nitrogen gas in the
air creating Nitric Acid ( HNO3 ) which can cause
corrosion to the metal material.
Please see the following countermeasure examples:
( 1 ) Incorporate an arc-extinguishing circuit
( 2 ) Lower the switching frequency
( 3 ) Lower the humidity of ambient atmosphere
• For secure operations, rated coil voltage should be
applied to the coil. In addition, please note that operate
and release voltages will vary according to the ambient
temperature and operating conditions.
• Abnormal heat, smoke, and/or fire may occur if the
relay is used outside the allowable ranges for the
coil ratings, contact ratings, expected life and other
specifications.
• Incorrect wiring may cause unexpected malfunction,
abnormal heat or fire.
• Check the ambient atmosphere when storing or
transporting the relays and devices containing the
relays. Icing or condensation may occur in the relay
causing damage. Avoid exposing the relays to heavy
loads, or strong shock and vibration.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー8ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
SF RELAYS Slim type Sockets/DIN rail terminal sockets
TYPES
■ Sockets
Type
PC board sockets
Number of poles
Type No.
Part No.
For 4 poles
SFS4-PS
AG1S844
For 6 poles
SFS6-PS
AG1S864
Standard packing
Inner carton
Outer carton
10 pcs.
100 pcs.
■ DIN rail terminal socket
Type
Number of poles
Type No.
Part No.
Terminal sockets for
spade and ring tongue
terminals
For 4 poles
SFS4-SFD-R
AG1S848
For 6 poles
SFS6-SFD-R
AG1S868
Standard packing
Inner carton
Outer carton
10 pcs.
100 pcs.
Note) Spade tongue terminal dedicated terminal sockets, please order AG1S847 for 4 poles and AG1S867 for 6 poles.
RATING
■ Specifications
Item
Specifications
Dielectric strength ( initial )
Between each terminal 2,500 Vrms for 1 min ( detection current: 10 mA )
Insulation resistance ( initial )
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
Max. continuous carrying current
6 A ( Reduce by 0.1 A/℃ for temperatures 70 to 85℃ )
Conditions for usage, transport and
storage
Ambient temperature: -40 to 85℃, Humidity 5 to 85% RH ( Avoid icing and condensation )
DIMENSIONS
CAD The CAD data of the products with a "CAD" mark can be downloaded from our Website.
Unit: mm
■ PC board sockets
● For 4 poles: AG1S844
CAD
External dimensions
Recommended PC board pattern
( BOTTOM VIEW )
15.0
50.0
40.0
10.16
4.1
0.8
(13)
10.16
(6.93)
13.97
0.4
11.43
3-φ3.2
(For M3 screw)
Please use the
screw with a stem
length of 8 mm
39.9
24.8
10-φ1.1
(6.93)
13.97
5.08
5.08
11.43
Tolerance: ±0.1
(13)
5.08
5.08
General tolerance: ±0.3
Schematic ( BOTTOM VIEW )
Standard
2 Form A 2 Form B mounted
1
3 4
With LED indication
With diode and
LED indication type
2 Form A 2 Form B mounted
2 Form A 2 Form B mounted
7 8
+
1
3 4
7 8
−
5 6
9 10
3 Form A 1 Form B mounted
1
3 4
2
+
5 6
9 10
3 Form A 1 Form B mounted
7 8
1
3
4
5 6
9 10
2
5 6
9 10
1
3 4
7 8
2
5 6
9 10
+
−
−
2
7 8
3 Form A 1 Form B mounted
7 8
+
−
3 4
−
−
2
1
+
+
2
5 6
9 10
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー9ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
● For 6 poles: AG1S864
CAD
External dimensions
Recommended PC board pattern
( BOTTOM VIEW )
15.0
60.0
40.0
10.16
4.1
0.8
24.8
Please use the
screw with a stem
length of 8 mm
14-φ1.1
(6.93)
13.97
5.08
5.08
5.08
5.08
11.43
Tolerance: ±0.1
(13)
(13)
(6.93)
10.16
3-φ3.2
(For M3 screw)
49.9
13.97
5.08
0.4
11.43
5.08
5.08
5.08
General tolerance: ±0.3
Schematic ( BOTTOM VIEW )
Standard
With LED indication
With diode and
LED indication type
4 Form A 2 Form B mounted
4 Form A 2 Form B mounted
4 Form A 2 Form B mounted
1
3 4
7 8 11 12
+
1
3
4
7 8 11 12
−
5 6
5 Form A 1 Form B mounted
1
3 4
2
9 10 13 14
+
5 6
9 10 13 14
5 Form A 1 Form B mounted
7 8 11 12
1
3 4
5
6
3 Form A 3 Form B mounted
1
3 4
5 6
9 10 13 14
3 Form A 3 Form B mounted
7 8 11 12
1
3 4
2
5 6
9 10 13 14
1
3 4
7 8 11 12
2
5 6
9 10 13 14
1
3 4
7 8 11 12
2
5 6
9 10 13 14
+
−
−
−
9 10 13 14
3 Form A 3 Form B mounted
7 8 11 12
+
+
5 6
−
2
9 10 13 14
2
+
−
2
7 8 11 12
5 Form A 1 Form B mounted
7 8 11 12
+
−
3 4
−
−
2
1
+
+
2
5
6
9 10 13 14
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 10 ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
■ Terminal socket for spade and ring tongue terminals ( finger protect type )
● For 4 poles: AG1S848
Mounting hole pattern
6.5
External dimensions
R2.0
M3 screw
2-M3.5 or φ4 hole
75.0
14.5±0.2
6.5
φ6.2±0.3
80.0±0.2
CAD
2-4×5 hole
Tolerance: ±0.1
6.3+0.3
0
62.4*
58.9
Schematic
( TOP VIEW )
10
7
8
2
1
9
6
4.0
35.4
22.4
5
General tolerance: ±0.5
4
* Reference value
Note) Ring tongue terminals cannot be used AG1S847.
In use of a ring tongue terminals, please use AG1S848.
3
● For 6 poles: AG1S868
Mounting hole pattern
6.5
External dimensions
R2.0
M3 screw
75.0
22.0±0.2
2-4×5 hole
6.5
φ6.2±0.3
Tolerance: ±0.1
6.3 +0.3
0
Schematic
( TOP VIEW )
35.4
4.0
58.9
62.4*
2-M3.5 or φ4 hole
80.0±0.2
CAD
29.8
General tolerance: ±0.5
14
12
13
11
10
8
9
7
6
4
* Reference value
Note) Ring tongue terminals cannot be used AG1S867.
In use of a ring tongue terminals, please use AG1S868.
5
2
1
3
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 11 ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
Safety Relays SF RELAYS Slim type
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ UL/C-UL ( Approved )
■ TÜV ( Approved )
File No.
File No.
E148103
B 013461 0318 Rev.03
GUIDELINES FOR USAGE
■ Installation on DIN rail
2 ) Refer to the figure for applicable solderless terminals.
1 ) Attach directly to the chassis or use a DIN rail.
Spade tongue terminal
( 1 ) When attaching directly to chassis
• Use a M3.5 screw, spring washer, and hex nut.
• For the mounting pitch, refer to the dimensions.
Max. 6.3 mm
Min. 3 mm
( 2 ) When installing on a DIN rail
• Use a 35 mm wide DIN rail ( DIN46277 ).
• Install and remove as shown in the figures.
< When installing >
Ring tongue terminal
Max. 6.3 mm Min. 3 mm
Push
DIN rail
< When removing >
Pull
Screwdriver
DIN rail
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 12 ー
Panasonic Industry Co., Ltd. 2024
ASCTB119E 202406
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Precautions for Coil Input
■ Long term current carrying
■ Coil connection
A circuit that will be carrying a current continuously for
When connecting coils of polarized relays, please check coil
long periods without relay switching operation. ( circuits
polarity ( +, − ) at the internal connection diagram
for emergency lamps, alarm devices and error inspection
that, for example, revert only during malfunction and
( Schematic ). If any wrong connection is made, it may
cause unexpected malfunction, like abnormal heat, fire and
output warnings with form B contacts ) Continuous, long-
so on, and circuit do not work. Avoid impressing voltages to
term current to the coil will facilitate deterioration of coil
insulation and characteristics due to heating of the coil itself.
the set coil and reset coil at the same time.
For circuits such as these, please use a magnetic-hold type
latching relay. If you need to use a single stable relay, use
a sealed type relay that is not easily affected by ambient
conditions and make a failsafe circuit design that considers
the possibility of contact failure or disconnection.
■ Maximum allowable voltage and temperature
rise
■ DC Coil operating power
Steady state DC current should be applied to the coil. The
wave form should be rectangular. If it includes ripple, the
ripple factor should be less than 5 %.
However, please check with the actual circuit since the
electrical characteristics may vary. The rated coil voltage
should be applied to the coil and the set/reset pulse time of
latching type relay differs for each relays, please refer to the
relay's individual specifications.
Proper usage requires that the rated coil voltage be
impressed on the coil. Note, however, that if a voltage
greater than or equal to the maximum continuous voltage
is impressed on the coil, the coil may burn or its layers short
due to the temperature rise. Furthermore, do not exceed the
usable ambient temperature range listed in the catalog.
● Operate voltage change due to coil temperature rise
In DC relays, after continuous passage of current in
the coil, if the current is turned OFF, then immediately
turned ON again, due to the temperature rise in the
coil, the operate voltage will become somewhat
higher. Also, it will be the same as using it in a higher
temperature atmosphere. The resistance/temperature
relationship for copper wire is about 0.4 % for 1 ℃,
and with this ratio the coil resistance increases. That
is, in order to operate of the relay, it is necessary that
the voltage be higher than the operate voltage and the
operate voltage rises in accordance with the increase
in the resistance value. However, for some polarized
relays, this rate of change is considerably smaller.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 13 ー
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Ambient Environment
■ Usage, Transport, and Storage Conditions
During usage, storage, or transportation, avoid locations
●Icing
subjected to direct sunlight and maintain normal
Condensation or other moisture may freeze on relays
when the temperature become lower than 0 ℃.This
temperature, humidity and pressure conditions.
●Temperature/Humidity/Pressure
icing causes the sticking of movable portion, the
When transporting or storing relays while they are tube
packaged, there are cases the temperature may differ
from the allowable range. In this case be sure to check
operation delay and the contact conduction failure etc.
Panasonic Industry Co., Ltd. does not guarantee the
the individual specifications.
failures caused by the icing.
The heat conduction by the equipment may accelerate
Also allowable humidity level is influenced by
the cooling of relay itself and the icing may occur.
temperature, please check charts shown below and
Please conduct product evaluations in the worst
condition of the actual usage.
use relays within mentioned conditions. ( Allowable
temperature values differ for each relays, please refer
to the relay's individual specifications. )
1) Temperature:
The tolerance temperature range differs for
each relays, please refer to the relay's individual
specifications
2) Humidity: 5 to 85 % RH
●Low temperature and low humidity
The plastic becomes brittle if the relay is exposed to a
low temperature, low humidity environment for long
periods of time.
●High temperature and high humidity
Storage for extended periods of time ( including
transportation periods ) at high temperature or high
humidity levels or in atmospheres with organic gases
or sulfide gases may cause a sulfide film or oxide film
to form on the surfaces of the contacts and/or it may
interfere with the functions. Check out the atmosphere
in which the units are to be stored and transported.
Humidity (% RH)
85
Allowable range
Avoid icing
when used at
temperatures
lower than 0°C
Avoid condensation when
used at temperatures higher
than 0°C
●Package
In terms of the packing format used, make every effort
to keep the effects of moisture, organic gases and
sulfide gases to the absolute minimum.
5
-40
0
85
Ambient temperature (℃)
3) Pressure: 86 to 106 kPa
●Silicon
●Dew condensation
Condensation occurs when the ambient temperature
drops suddenly from a high temperature and humidity,
or the relay is suddenly transferred from a low ambient
temperature to a high temperature and humidity.
Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by condensation.
The heat conduction by the equipment may accelerate
the cooling of device itself, and the condensation may
occur.
Please conduct product evaluations in the worst
condition of the actual usage. ( Special attention should
be paid when high temperature heating parts are close
to the device. Also please consider the condensation
may occur inside of the device. )
When a source of silicone substances ( silicone rubber,
silicone oil, silicone coating materials and silicone filling
materials etc. ) is used around the relay, the silicone gas
( low molecular siloxane etc. ) may be produced.
This silicone gas may penetrate into the inside of the
relay. When the relay is kept and used in this condition,
silicone compound may adhere to the relay contacts
which may cause the contact failure. Do not use any
sources of silicone gas around the relay ( Including
plastic sealed types ).
●NOx Generation
When relay is used in an atmosphere high in humidity
to switch a load which easily produces an arc, the NOx
created by the arc and the water absorbed from outside
the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely
affects operation.
Avoid use at an ambient humidity of 85 % RH or higher
( at 20 ℃ ). If use at high humidity is unavoidable,
please contact our sales representative.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 14 ー
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Others
■ Cleaning
• Cleaning with the boiling method is recommended ( The
• Although the environmentally sealed type relay ( plastic
sealed type, etc. ) can be cleaned, avoid immersing
temperature of cleaning liquid should be 40 ℃ or lower ).
the relay into cold liquid ( such as cleaning solvent )
immediately after soldering. Doing so may deteriorate the
Avoid ultrasonic cleaning on relays. Use of ultrasonic
cleaning may cause breaks in the coil or slight sticking of
sealing performance.
the contacts due to ultrasonic energy.
Please refer to "the latest product specifications"
when designing your product.
•Requests to customers:
https://industrial.panasonic.com/ac/e/salespolicies/
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 15 ー
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industrial.panasonic.com/ac/e/
©Panasonic Industry Co., Ltd. 2024
Specifications are subject to change without notice.