Safety Devices
New Products Line Up
Introducing a safety door
switch with solenoid
interlock that is among
the world’s thinnest*
Safety is assured
during maintenance!
2013.07
panasonic.net/id/pidsx/global
* Based on research conducted by our company as of March 2013.
Introducing a range of new
safety devices!
Panasonic Industrial Devices SUNX offers comprehensive safety solutions through an
extensive selection of safety devices and a robust support system.
SAFETY SOLUTION
Pushbutton type
Emergency stop switch
SG-E1
P.16~
SEMI emergency off
(EMO) switch
Enable grip switch
SG-C1
P.14~
Safety door switch with key /
Key selector switch
SG-B2 / SG-D1
2
P.8~ / P.12~
Ultra-slim
Safety door switch with solenoid
interlock / Safety door switch
SG-B1 / SG-A1
P.4~
Light curtain
SF4B / SF2B
* For product details, please refer to individual product
catalogs or our website.
Safety relay unit
SF-AC
* For product details, please refer to individual product
catalogs or our website.
3
Safety door switch with solenoid interlock
SG-B1
Ultra-slim
SERIES
Introducing a safety door switch with solenoid
interlock that is among the world’s thinnest*!
ased on research conducted by our company as of
With 5 built-in contacts * BMarch
2013.
75 mm 2.953 in
15 mm 0.591 in
Thin
body
75 mm 2.953 in
Safety door switch
SG-A1
Ultra-slim
SERIES
Manual lock release can be
operated from three directions.
Space saving design with
angled connection cable
Angled
connection
cable
Mi
30 nimu
mm m r
1.1 adiu
81 s
in
Mi
30 nimu
mm m r
1.1 adiu
81 s
in
SG-B1 series
Space saving
approx. 30 mm
1.181 in
Connectable safety
relay units
All models come with cables pre-installed.
The SG-B1 series and SG-A1 series ship with bundled cables already connected internally.
Since there is no need to provide cables separately, and because they are already
connected internally, the number of wiring man-hours is cut in half.
SF-AC Supports up to control category 3
• 2NC inputs, safety output × 3
SG-B1 series / SG-A1 series
Standard
door
switch
Cable
Integrated
design
Ships standard
with cables.
Energy-saving design
Order guide
Contact configuration /
Operating patterns
Specifications
Precautions for proper use
Dimensions
4
P.7
P.18
P.19
P.20~
P.22~
The SG-B1 series features an energy-saving
design requiring current consumption of just 110
mA at 24 V DC (100 mA for the solenoid and 10
mA for the indicator), even though it also
incorporates a solenoid interlock.
Low power consumption of 110 mA
Can be installed on any door.
Sliding doors
SG-B1
Top mounting
Top mounting
series
Actuator
Rightopening
Leftopening
Front mounting
Front mounting
Rightopening
Leftopening
Hinged doors
Top mounting
Side mounting
Leftopening
Rightopening
Rightopening
Leftopening
Bottom mounting
Side mounting
Up-opening
SG-B1 series
Choose between two types of locks:
• Spring lock
• Magnet lock
Easy-to-see LED
Wide viewing angle (approx. 120°)
operation indicator
Up-opening
SG-A1 series
Features three built-in
contacts yet is among world’s
smallest designs.
Choose from two actuator
entry slot orientations.
The indicator is visible
even from an angle.
Mounting surface
5
Dimensions
(Unit: mm in)
SG-B1 series
SG-A1 series
(with solenoid interlock)
30 1.181
15 0.591
75 2.953
15 0.591
78 3.071
75 2.953
Mounting hole layout
(Unit: mm in)
SG-B1 series
50.8 2.000
30
1.181
30
1.181
50.8 2.000
50.8 2.000
50.8 2.000
SG-A1 series
(with solenoid interlock)
SG-B1
seriesseries
SG-B1
28.5 1.122
28.5 1.122
1 0.039
20 1200.039
1 0.039
1 0.039
0.787 0.787
1 0.039
20 1200.039
1 0.039
1 0.039
0.787 0.787
Common actuators
SG-B1 series
(with solenoid interlock)
Horizontal / Vertical angle adjustable actuators
SG-K13
SG-K14
SG-A1 series
Straight actuator
SG-K11
6
Right-angle actuator
SG-K12
Right-angle actuator
(with plate)
SG-K12A
SG-B1 series
SG-A1 series
Features
P.4~
Order guide
P.7
Contact configuration / Operating patterns
P.18
Specifications
P.19
Precautions for proper use
P.20~
Dimensions
P.22~
Order guide
Safety door switch with solenoid interlock
Actuators are not included with door switches and must be purchased separately.
Interlock
force
Type
Main
contacts
Door monitor Lock monitor
contacts
contacts
1NC
Spring
lock type
1NO
500 N or more
1NC + 1NC
2NC
1NC
Magnet
lock type
1NO
Cable
length
Model No.
1 m 3.281 ft
SG-B1-SA-G1
5 m 16.404 ft
SG-B1-SA-G5
1 m 3.281 ft
SG-B1-SB-G1
5 m 16.404 ft
SG-B1-SB-G5
1 m 3.281 ft
SG-B1-MA-G1
5 m 16.404 ft
SG-B1-MA-G5
1 m 3.281 ft
SG-B1-MB-G1
5 m 16.404 ft
SG-B1-MB-G5
Safety door switch
Actuators are not included with door switches and must be purchased separately.
Door monitor
contacts
2NC
2NC + 1NO
3NC
Cable
length
Model No.
1 m 3.281 ft
SG-A1-02-1
5 m 16.404 ft
SG-A1-02-5
1 m 3.281 ft
SG-A1-12-1
5 m 16.404 ft
SG-A1-12-5
1 m 3.281 ft
SG-A1-03-1
5 m 16.404 ft
SG-A1-03-5
Actuators
Actuators are not included with door switches and must be purchased separately.
Type
• SG-K11
• SG-K12
• SG-K13
• SG-K14
• SG-K12A
Model No.
Straight actuator
SG-K11
Right-angle actuator
SG-K12 (Note 1)
Right-angle actuator (with plate)
SG-K12A
Horizontal / vertical angle
adjustable actuators (Note 2)
SG-K13
SG-K14
Notes: 1) The right-angle SG-K12 actuator’s tensile strength is 100
N. Using the device with a load in excess of this value
may cause it to fall off the door. If you anticipate that the
tensile load during use will exceed 100 N, use the
right-angle (with plate) SG-K12A.
2) Choose a model after verifying the required direction of
operation based on the relationship between the door
and safety switch. (Refer to p.21)
7
Safety door switch with key
SG-B2
Solve issues related to machine safety and other safety measures with a
safety door switch with key!
SERIES
No
forgotten
keys
No
locked-in
workers
No
inadvertent
machinery
operation
The safety door switch with key SG-B2 series locks and unlocks doors with keys.
When an operator takes a key into a hazardous area, the safety door switch will not lock, and
the equipment will stop, ensuring operator safety by preventing personnel from being closed
inside the hazardous area and preventing equipment from starting to operate.
Safety worker
Safety door switch
with key
SG-B2 series
ACTION
1
ACTION
1
ACTION
2
ACTION
Door unlocked
2
Key brought into the hazardous area
Hazards of the system and robot are isolated by the safety guard. The worker uses the key
to unlock the door and disables the system from starting unexpectedly, then removes the
key and brings it into the hazardous area. The system remains off until the worker walks out
the door and locks the door with the key. This enables the worker carrying the key to work
safely in the hazardous area.
Connectable safety
relay units
Additionally, the key selector switch SG-D1 series can be used to switch
equipment modes and unlock door locks with a single key.
Partial mode change
SF-AC Supports up to control category 3
• 2NC inputs, safety output × 3
ACTION
2
Key selector switch
SG-D1 series
Single key!
ACTION
1
Safety door switch
with key
SG-B2 series
ACTION
1
Order guide
Options
Contact configuration /
Operating patterns
Specifications
Precautions for proper use
Dimensions
8
P.10
P.11
P.25
P.26
P.26~
P.28~
Door unlocked (safety output off)
ACTION
2
Equipment mode change
Hazards of the system and robot are isolated by the safety guard. When a worker needs to work
inside the hazardous area for maintenance, the worker unlocks the safety guard using a key,
disables the system from starting (1), removes the key and brings it into the hazardous area, and
then changes the operation mode of each system to maintenance mode (2). While the worker is
carrying out maintenance work in the hazardous area, the safety guard cannot be locked and the
system cannot be turned on. This enables the worker to work safely in the hazardous area.
Energy-saving design, no power supply required
Since doors are locked and unlocked with a key, there is no need to supply power to the safety door switch.
Head removal detection function
Head removal detection function is employed in the SG-B2. With this innovative function, the monitor circuit (41-42) turns off when the head is
removed from the switch, such as when removing the head to change the head direction.
With the head installed on the switch, monitor circuits 41-42 and 51-52 operate in synchronization while the key locks / unlocks the actuator.
When the head is removed, 41-42 turns off and 51-52 turns on.
This disagreement is detected by the head removal detection function.
Monitor circuit
(41-42) with head
removal detection
function
Actuator unlocked
LOCK
Head removed
Actuator unlocked
Actuator locked
When the head removed
UNLOCK
Monitor circuit (NC) Pink
41
42 Pink / White
OFF
ON
OFF
Monitor circuit (NC) Brown
51
52 Brown / White
OFF
ON
ON
Note: Head removal detection function is not direct opening.
High-security pin tumbler key
types are used
Disagreement
Monitor circuit
Actuator locked
Available with rear unlocking button
Models with a rear unlocking
button allow the door to be
unlocked from the inside in
the event a worker is left in
the hazardous area.
All models come with cables
pre-installed.
Equipment combination examples related
to machine safety
Double-insulated design eliminates
the need for grounding wires.
Choose an actuator based on the
door shape and application.
Straight actuator
SG-K21 / SG-K21A
Pushbutton type
emergency stop switch
SG-E1 series
Enable grip switch
SG-C1 series
Safety relay unit
SF-AC
Right-angle actuator
SG-K22 / SG-K22A
Slide actuator
SG-K21S
Horizontal / vertical angle
adjustable actuators
SG-K24
Key selector switch
SG-D1 series
Safety door switch with key
SG-B2 series
9
Order guide
Safety door switch with key
Actuators are not included with door switches and must be purchased separately.
Rear unlocking
button
11
Monitor circuit :
Monitor circuit :
Blue
Monitor circuit :
Orange 2 3
Monitor circuit :
1 2 Blue /
White
2 4 Orange /
White
UNLOCK
LOCK
Pink
41
4 2 Pink /
White
Brown 5 3
Monitor circuit : Blue
Monitor circuit :
Monitor circuit : Orange
Monitor circuit :
Monitor circuit : Blue
Monitor circuit :
Monitor circuit : Orange
Monitor circuit :
11
1 2 Blue /
White
21
2 2 Orange /
White
11
1 2 Blue /
White
21
2 2 Orange /
White
5m
16.404 ft
5 4 Brown /
White
Without
With
Cable
length
Contact arrangement (Note)
Pink
41
4 2 Pink /
White
Brown
51
5 2 Brown /
White
Pink
41
4 2 Pink /
White
Brown
51
5 2 Brown /
White
5m
16.404 ft
5m
16.404 ft
Note: The contact configuration shows the status when the actuator is inserted and the switch is locked.
Key LOCK and UNLOCK positions are as shown on the right.
Key removal
position
Model No.
A
(removable in all
positions)
B
(removable in
UNLOCK position)
C
(removable in
LOCK position)
A
(removable in all
positions)
B
(removable in
UNLOCK position)
C
(removable in
LOCK position)
A
(removable in all
positions)
B
(removable in
UNLOCK position)
C
(removable in
LOCK position)
SG-B2-K2AC-5
SG-B2-K2BC-5
SG-B2-K2CC-5
SG-B2-K2AD-5
SG-B2-K2BD-5
SG-B2-K2CD-5
SG-B2-K2AD-L5
SG-B2-K2BD-L5
SG-B2-K2CD-L5
Switches incorporate two detents
so that they stop in each position.
UNLOCK
LOCK
Actuators
Actuators are not included with door switches and must be purchased separately.
Type
Description
Model No.
Straight actuator
SG-K21
Straight actuator with rubber
bushings
SG-K21A
Slide actuator
The actuator tensile strength when using this product is 1,400 N.
SG-K22
Right-angle actuator
Right-angle actuator with
rubber bushings
Horizontal / vertical angle
adjustable actuators
SG-K21S
SG-K22A
The actuator tensile strength when using this product is 500 N.
SG-K24
Note: When using a safety door switch with key on a hinged door, see page 27 for more information about the minimum door radius with
which the switch can be used.
• SG-K21
10
• SG-K21A
• SG-K21S
• SG-K22
• SG-K22A
• SG-K24
Features
P.8~
SG-B2 series
Order guide
P.10
Options
P.11
Contact configuration / Operating patterns
P.25
Specifications
P.26
Precautions for proper use
P.26~
Dimensions
P.28~
Options
Type
Model No.
Padlock hasp (Note 1)
SG-PH2
Mounting plate (for mounting on an aluminum frame)
MS-SG-21
Rear unlocking button kit for a frame (Note 2)
MS-SG-22
MS-SG-23
Notes: 1) The shackle diameter for compliant padlocks ranges from ø5.5 to ø7.5 mm
ø0.217 to ø0.295 in.
Shackle diameter: ø5.5 to ø7.5 mm ø0.217 to ø0.295 in
2) For more information about selecting a back manual unlock button kit for
a frame, see the following table:
Mounting part* thickness (X) (mm in)
Model No.
Rear unlocking button type
When installing an SG-B2-K2□D-L5 with a rear
unlocking button directly
MS-SG-22
33 < X ≤ 43 1.299 < X ≤ 1.693
MS-SG-23
23 < X ≤ 33 0.906 < X ≤ 1.299
* The mounting part is a frame or a panel that the product is mounted on.
Padlock hasp
Mounting plate (for mounting on an aluminum frame)
Rear unlocking button kit for a frame
• SG-PH2
• MS-SG-21
• MS-SG-22
• MS-SG-23
11
Key selector switch with direct open operation function
Pin tumbler design for high security
Key selector switch
SG-D1
SERIES
Mode change
Key selector switch
SG-D1 series
ACTION
1
ACTION
1
Mode change
Workers can be limited by using a key selector switch to switch modes when performing
maintenance and program overwrites. Additionally, since the NC contact (b-contact) use
direct open operation, the circuit will be reliably shut off by forcibly separating the NC
contact, even if they have melted together.
Use in combination with the safety door switch
with key SG-B2 series to enable hostage control.
Partial mode change
ACTION
2
Key selector switch
SG-D1 series
Single key!
ACTION
1
Safety door switch
with key
SG-B2 series
ACTION
1
Order guide
Options
Specifications
Precautions for proper use
Dimensions
12
P.13
P.13
P.35
P.35
P.36
Door unlocked (safety output off)
ACTION
2
Mode change
Hazards of the system and robot are isolated by the safety guard. When a worker needs to
work inside the hazardous area for maintenance, the worker unlocks the safety guard using
a key, disables the system from starting (1), removes the key and brings it into the
hazardous area, and then changes the operation mode of each system to maintenance
mode (2). While the worker is carrying out maintenance work in the hazardous area, the
safety guard cannot be locked and the system cannot be turned on. This enables the
worker to work safely in the hazardous area.
SG-D1 series
Features
P.12
Order guide
P.13
Options
P.13
Specifications
P.35
Precautions for proper use
P.35
Dimensions
P.36
Order guide
Key selector switch
Position
Contact
configuration
1NO / 1NC
(11)
Contact block
Mounting position
(Note)
①
2NO / 2NC
(22)
Maintained
1
2
(Manual)
90 degree,
2-position
1NO / 1NC
(11)
2NO / 2NC
(22)
1NO / 1NC
(11)
2NO / 2NC
(22)
Operator position
Contact
1
NO
②
NC
①
NO
②
NC
③
NO
④
NC
①
NO
②
NC
①
NO
②
NC
③
NO
④
NC
①
NO
②
NC
①
NO
②
NC
③
NO
④
NC
2
Key removal
position
Model No.
SG-D1-2A11
A: All positions
①
②
SG-D1-2A22
SG-D1-2B11
B: Left position
Not removable in
right position
①
SG-D1-2B22
❷
SG-D1-2C11
C: Right position
Not removable in
left position
SG-D1-2C22
❶
②
Note: Contact blocks are attached as shown below:
③④
②
①
Options
Type
Locking ring wrench
Model No.
Description
SG-ET1
Used to tighten the locking ring when
installing the unit onto a panel.
Material: Brass
Weight: approx. 150 g
* Tighten the locking ring to a torque
of 2.0 N·m.
Locking ring wrench
• SG-ET1
13
Compact, light weight grip switches designed to fit
comfortably in the hand
Enable grip switch
SG-C1
SERIES
(Push monitor switch)
This product line includes models with control
units suited to a variety of applications.
The compact, light weight grip profile was designed
based on human engineering considerations.
The compact profile fits the hand perfectly, ensuring comfortable operation. Thanks to its
light weight design (SG-C1-21: approx. 140 g) and compact size, it is easy to hold even for
individuals with small hands, and it can also be used in confined work locations.
Reduced impact during extended operation
We reduced the impact during extended operation by lowering the holding load in
position 2 (ON).
Pleasant, clear button operation
Tactile clicking feedback allows easy recognition of switch operation when shifting from
position 1 (contact OFF) to position 2 (contact ON).
Position 1
OFF
Position 2
Squeeze
gently.
Release.
ON
Order guide
Contact configuration /
Operating patterns
Specifications
Precautions for proper use
Dimensions
14
P.15
P.15
P.31
P.31~
P.32
Position 3
Grip
strongly.
Release.
OFF
Features
P.14
SG-C1 series
Order guide
P.15
Contact configuration / Operating patterns
P.15
Specifications
P.31
Precautions for proper use
P.31~
Dimensions
P.32
Order guide
Enable grip switch
Contact configuration
3 position
enabling
switch
Additional control units
Push
monitor
switch
Emergency
stop switch
Control unit
(A)
Control unit
(B)
Indicator
(green) (C)
Rubber boot
material /
Color
Wiring
style
SG-C1-21
Without
With (2NC)
2 contacts
With (1NC)
Without
With (2NC)
SG-C1-21-E
Without
Without
With
Momentary
pushbutton switch
(2c)
Momentary
pushbutton
switch
(2c)
Model No.
Silicone rubber /
(Yellow) (Note)
Solder
terminal
SG-C1-21-EG
SG-C1-21-MM
SG-C1-21-EMM
Without
SG-C1-21-EMK
Key selector switch (2c)
Additional control unit layout
Emergency
stop switch
Emergency
stop switch
Control unit
(A)
Indicator (C)
Control unit
(B)
Note: Silicone rubber: Can be used in general factories. Remains flexible in cold temperatures. Suitable in applications with a wide operating temperature range.
Contact configuration / Operating patterns
Grip switch (during operation of center of the rubber boot)
Terminal No.
Solder terminal
Position 2
Position 1
Position 3
3 position enabling switch: 2 contacts; pin No.: NO1-C1, NO2-C2
Push monitor switch: 0, 1 contacts: pin No.: 31-32 (SG-C1-21□)
NO1-C1
Push
(Position 1→2→3)
31-32
NO2-C2
Note: Push monitor switch (terminal No.31-32) will be positive opening
circuit ( ) when the switch operates from position 2 to 3.
Use contacts of terminal No. NO1-C1 and NO2-C2 for the output of
enabling system.
The above operating characteristics illustrate the performance when
the center of the rubber boot is pressed. Pressing the edge activates
one of the two 3 position enabling switches inside earlier than the
other, and may cause a delay in the operation.
NO1-C1
Release
31-32
(Position 2→1)
NO2-C2
NO1-C1
Release
31-32
(Position 3→1)
NO2-C2
: Contact ON (closed)
: Contact OFF (opened)
Key selector switch
Operator position & contact operation (top view)
Position
(Left)
Key removal position
Left contact
NO1
Maintained
1
2
NC1
(Right)
Right contact
NO2
NC2
Left contact
NO1
NC1
Right contact
NO2
NC2
Removable in all
positions
C1
C2
Indicator
Pay attention to the polarity of the power supply as SG-C1-21-EG do not
contain a diode for protection against reverse polarity.
On solder terminal units, the terminal with a white paint marking is positive.
C1
C2
Negative terminal
White paint marking
Terminal (plastic)
Positive terminal
15
Push to lock, turn to reset
Emergency stop switch
SG-E1
Pushbutton type
SERIES
Switches feature simple operation: Push the pushbutton to lock the switch, and turn the
switch in the direction shown by the arrow to reset it.
Push to lock
Turn to reset
The product line includes a SEMI emergency off
(EMO) switch.
SEMI emergency off (EMO)
switch Pushbutton type
SEMI semiconductor industry safety standards
SEMI standards comprise a series of guidelines put together by an industry group consisting
of manufacturers of semiconductor manufacturing equipment, flat-panel displays, and
associated materials. In the semiconductor industry, this guidelines have achieved the status
of de facto international standards.
Section 12.1 of the SEMI standards (S2 0706) states, “Equipment should incorporate an
emergency off (EMO) circuit. When the EMO actuator (button) is triggered, the equipment
should transition to a safe state in which no new hazard is posed to workers or equipment.”
This provision likely stems from the need to address the possibility of secondary hazards that
could occur when processing power and other inputs are stopped, reflecting the industry’s
extensive use of materials such as solvents and chemicals, many of which contain hazardous
or toxic substances. Consequently, SEMI standards require that normal emergency stop
switches, which shut off the supply of energy, including power, be augmented with separate
emergency off switches that shut off only the portion of the load that created the hazardous
state while maintaining operation of other safety-related equipment (smoke detectors, gas /
water leak detectors, pressure measurement equipment, etc.).
When there is the possibility that the emergency off switch could be operated mistakenly, a
guard must be installed and the switch must use direct opening operation. The button must be
red with a yellow background, and the switch itself must include the letters “EMO.”
When installing a SEMI emergency off (EMO) switch on semiconductor manufacturing
equipment, it should be installed at a height of 838 to 1,638 mm 32.992 to 64.488 in.
(SEMI S8-0705)
According to SEMI standards, the EMO emergency stop switch must be installed within
3 m 9.843 ft of the work location.
(SEMI S2-0706 12.5.2)
3 m 9.843 ft or less
EMO
Order guide
Options
Specifications
Precautions for proper use
Dimensions
16
P.17
P.17
P.33
P.33
P.34
3 m 9.843 ft or less
Worker
EMO
Max. installation
height
1,638mm 64.488 in
Min. installation
height
838mm 32.992 in
SG-E1 series
Features
P.16
Order guide
P.17
Options
P.17
Specifications
P.33
Precautions for proper use
P.33
Dimensions
P.34
Order guide
Emergency stop switch
Type
Contact configuration
Button color
Model No.
SG-E1-02
2NC
Pushlock
Turn reset
Red
SG-E1-12
1NO / 2NC
SEMI emergency off (EMO) switch
Type
Pushlock
Turn reset
Main contacts
(NC contacts)
Monitor contacts
(NO contacts)
2NC
—
Button color
/ text color
Model No.
SG-E1-02-E
Red / White
2NC
SG-E1-12-E
1NO
Options
Type
Model No.
SG-EP1
SG-EP2
SG-EP3
Locking ring
wrench
SG-ET1
SEMI guard ring
MS-SG-GR1
(Blank)
Legend
Emergency stop
nameplate
Emergency stop nameplate
Description
EMERGENCY
STOP
非常停止
(Japanese)
• SG-EP1
• SG-EP3
Background: Yellow
Legend: Black
Applicable panel thickness:
0.8 to 4.5 mm
0.031 to 0.177 in
Material: Polyamide
Used to tighten the locking ring when installing the unit
onto a panel.
Material: Brass, Weight: approx. 150 g
* Tighten the locking ring to a torque of 2.0 N·m.
Locking ring wrench
• SG-ET1
For SEMI emergency off (EMO) switches.
Specifically designed for use with semiconductor
manufacturing equipment.
Caution
SEMI guard rings are designed specifically for use with semiconductor manufacturing
equipment and should not be used as emergency stop switches for machine tools, food
processing machinery, or other equipment.
The European Machinery Directive, IEC 60204-1, JIS B9960-1, and other standards
require that emergency stop switches be easy to approach and operate, and use of
SEMI standard-compliant switch guards is not currently approved.
(
• SG-EP2
SEMI guard ring
• MS-SG-GR1
)
17
SG-B1
SG-A1
Ultra-slim
SERIES
Ultra-slim
SERIES
Safety door switch with solenoid interlock
Safety door switch
Contact configuration / Operating patterns
Safety door switch with solenoid interlock
Safety door switch
Safety door switch with solenoid interlock
: Closed
: Open
Unlocking using
Status 1
Status 2
Status 3
Status 4
manual unlocking key
• Door closed
• Door closed
• Door open
• Door open
• Door closed
• Machine ready to operate • Machine cannot be operated • Machine cannot be operated • Machine cannot be operated • Machine cannot be operated
• Solenoid de-energized • Solenoid energized
• Solenoid energized
• Solenoid de-energized • Solenoid de-energized
Safety switch status
Door status
SG-B1
SG-A1
Manual unlocking
position
• Closed (locked) • Closed (unlocked) • Open
Safety door switch with key
Door
Spring lock type
SG-B1-SA-□
Magnet lock type
SG-B1-MA-□
(At actuator entry) (When solenoid off)
Enable grip switch
SG-C1
Model No. and contact configuration
Door monitor Lock monitor
SG-B2
(+)(When solenoid(–)
(At actuator entry)
off)
SG-B1-SB-□
Magnet lock type
SG-B1-MB-□
Main circuit:
Monitor circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
11
21
11
31
21
31
• Closed (unlocked)
Main circuit
11-42
Door monitor Lock monitor
Main circuit: 11
Monitor circuit: 21
Main circuit: 11
Monitor circuit: 31
Monitor circuit: 21
Spring
type31
Monitorlock
circuit:
• Open
A2
(+)
12A2
41
22 51
12 41
32
22 51
32
A1
(–)
42
A1
52
42
52
Door monitor circuit
(door closed)
21-22
Door monitor circuit
(door closed)
31-32
Lock monitor circuit
(locked)
51-52
Main circuit
11-42
Door monitor circuit
(door closed)
21-22
12
22
12
32
22
32
41
53
41
53
Door monitor circuit
(door closed)
31-32
42
54
42
54
Lock monitor circuit
(unlocked)
53-54
Spring lock type
• OFF (de-energized) • ON (energized) • ON (energized) • OFF (de-energized) • OFF (de-energized)
Solenoid power A1-A2 (same for all models)
• ON (energized) • OFF (de-energized) to
Magnet lock type
• ON (energized) • OFF (de-energized) • OFF (de-energized)
ON (re-energized)
(Note 2)
Solenoid power A1-A2 (same for all models)
(Note 1)
(Note 2)
Emergency stop switch
Main circuit: Connected to the machine drive control circuit, sending the interlock signals of the protective door.
Monitor circuit: Sends the monitoring signals of open / closed and lock / unlocked statuses of the protective door.
Notes: 1) Do not attempt manual unlocking while the solenoid is energized.
2) Do not energize the solenoid for a long period of time while the door is open or while the door is unlocked manually.
: Contact ON (closed)
: Contact OFF (opened)
• Operation characteristics
(reference)
0 (Actuator mounting reference position)
Approx. 1.1 0.043 (Lock)
SG-B1-SA-□
Approx. 4.7 0.185
Approx. 27.4 1.079
Approx. 5.0 0.197
SG-B1-MA-□
(Travel: mm in)
SG-E1
Main circuit (11-42)
Door monitor circuit (21-22)
Door monitor circuit (31-32)
Lock monitor circuit (51-52)
(Actuator completely inserted)
SG-B1-SB-□
SG-B1-MB-□
Main circuit (11-42)
Door monitor circuit (21-22)
Door monitor circuit (31-32)
Lock monitor circuit (53-54)
0 (Actuator mounting reference position)
Approx. 1.1 0.043 (Lock)
Approx. 4.7 0.185
Approx. 5.0 0.197 Approx. 27.4 1.079
(Travel: mm in)
(Actuator completely inserted)
(Actuator pulled out)
(Actuator pulled out)
Key selector switch
• The operation characteristics show the contact status when the actuator enters an entry slot of an safety switch.
• The operation characteristics shown in the chart above are of the SG-K11 / SG-K12 / SG-K13 and SG-K14 actuators. For the SG-K12A actuator, subtract
0.6 mm 0.024 in.
Safety door switch
Model No.
Contact configuration
SG-A1-02-□
2NC
11
31
12
32
12
22
34
11-12
21-22
33-34
12
22
32
11-12
21-22
31-32
SG-D1
18
Operation characteristics
0.8 0.031 (Actuator mounting reference position)
Approx. Approx.
Approx. 28.2 1.110 (Travel: mm in)
0
SG-A1-12-□
2NC + 1NO
11
21
33
SG-A1-03-□
3NC
11
21
31
5.5 0.217 5.8 0.228
11-12
31-32
(Actuator completely inserted)
: Contact ON (closed)
: Contact OFF (opened)
(Actuator pulled out)
SG-B1SERIES / SG-A1SERIES
Specifications
SG-B1
SG-A1
SG-B2
SG-C1
Emergency stop switch
Applicable
EN 1088, IEC 60947-5-1, EN 60947-5-1,
standards
GS-ET-15, UL 508, CSA C22.2 No.14
Standards for use
IEC 60204-1, EN 60204-1
Applicable
Machinery directive (2006/42/EC)
directives
Low voltage directive (2006/95/EC)
Ambient
-25 to +70 °C -13 to +158 °F (No dew condensation or icing allowed)
temperature Storage: -40 to +80 °C -40 to +176 °F
Ambient humidity
45 to 85 % RH
Pollution degree
3 (Inside 2)
Altitude
2,000 m 6,561.68 ft max.
Impulse withstand
4 kV
voltage (Uimp)
Rated insulation
300 V
voltage (Ui)
Thermal current
2.5 A
(Ith)
Ie
Ue 30 V 125 V 250 V
Rated operational
Resistive load (AC-12)
2.5 A 1.5 A
AC
voltage (Ue) /
Inductive load (AC-15)
1.5 A 0.75 A
Rated operational
Resistive load (DC-12) 2.5 A 1.1 A 0.55 A
current (Ie)
DC
Inductive load (DC-13) 2.3 A 0.55 A 0.27 A
Electric shock
Class II (IEC 61140), (double insulated)
protection class
Protection
IP 67 (IEC 60529)
Malfunction: 300 m/s2
Shock resistance
Destruction: 1,000 m/s2
Vibration
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
resistance
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
Operating
1,200 operations/hour
frequency
Actuator
0.05 to 1.0 m/sec.
operating speed
2,000,000
B10d
(ISO 13849-1 Annex C Table C.1)
Mechanical
1,000,000 operations min. (GS-ET-15)
durability
100,000 operations min. (AC-12, 250 V 1.5 A,
Electrical
DC-12 250 V 0.2 A)
1,000,000 operations min. (AC/DC 24 V 100 mA)
durability
(1,200 operations/hour)
Direct opening travel
8 mm 0.315 in min.
Direct opening force
60 N min.
Contact
300 mΩ max. (initial value, 1 m 3.281 ft cable)
700 mΩ max. (initial value, 5 m 16.404 ft cable)
resistance
Short-circuit
Use 250 V / 10 A fast acting type fuse
protective device
Conditional
50 A (250 V)
short-circuit current
Material
Enclosure: PA66
Cable
UL style 2464, No.20 AWG 6-core
SG-A1-□-1: Approx. 120 g, SG-A1-□-5: Approx. 420 g
Weight
SG-E1
Key selector switch
Solenoid / Indicator
DC
Safety door switch
SG-A1 series
Enable grip switch
AC
DC
AC
Operating condition
Designation
Series
Safety door switch with key
Applicable
EN 1088, IEC 60947-5-1, EN 60947-5-1,
standards
GS-ET-19, UL 508, CSA C22.2 No.14
Standards for use
IEC 60204-1, EN 60204-1
Applicable
Machinery directive (2006/42/EC)
directives
Low voltage directive (2006/95/EC)
Ambient
-25 to +50 °C -13 to +122 °F (No dew condensation or icing allowed)
temperature
Storage: -40 to +80 °C -40 to +176 °F
Ambient humidity
45 to 85 % RH
Pollution degree
3 (Inside 2)
Altitude
2,000 m 6,561.68 ft max.
300 V (Door monitor circuit)
Rated insulation
150 V (Main, Lock monitor circuit)
voltage (Ui)
30 V (Between ground and LED, solenoid circuit)
Impulse
2.5 kV (Door monitor circuit)
withstand voltage 1.5 kV (Main, Lock monitor circuit)
(Uimp)
0.5 kV (Between ground and LED, solenoid circuit)
Ambient temperature:
Ambient temperature
Thermal current -25 to +35 °C -13 to +95 °F 35 to +50 °C 95 to +122 °F
(Ith)
2.5 A (up to 2 circuits)
1.0 A (1 circuit)
1.0 A (3 or more circuits) 0.5 A (2 or more circuits)
Ue 30 V 125 V 250 V
Ie
Resistive
load
(AC-12)
2A
Main
Rated
1A
circuit, look Inductive load (AC-15)
operational
monitor
Resistive load (DC-12) 2 A 0.4 A
voltage (Ue) /
circuit
Inductive load (DC-13) 1 A 0.22 A
Rated
Resistive load (AC-12)
2.5 A 1.5 A
operational
Door
Inductive load (AC-15)
1.5 A 0.75 A
current (Ie)
monitor
Resistive load (DC-12) 2.5 A 1.1 A 0.55 A
circuit
Inductive load (DC-13) 2.3 A 0.55 A 0.27 A
Electric shock protection class Class II (IEC 61140) (Note 1), (double insulated)
Operating frequency
900 operations/hour
Actuator operating speed
0.05 to 1.0 m/sec.
2,000,000
B10d
(ISO 13849-1 Annex C Table C.1)
Mechanical durability
1,000,000 operations min. (GS-ET-19)
100,000 operations min.
900 operations/hour,
AC-12 125 V 2A, DC-12 125 V 0.4 A
Electrical
1,000,000 operations min.
durability
900 operations/hour,
24 V AC/DC 0.1 A resistive load
Interlock force
500 N min. (GS-ET-19) (Note 2)
Direct opening travel
8 mm 0.315 in min.
Direct opening force
60 N min.
300 mΩ max. (initial value, 1 m 3.281 ft cable)
Contact
700 mΩ max. (initial value, 5 m 16.404 ft cable)
resistance
Protection
IP 67 (IEC 60529)
Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2
Vibration
Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
resistance
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
Short-circuit protective device
Use 250 V / 10 A fast acting type fuse
Material
Enclosure: PA66
Cable
UL style 2464, No.22 AWG 12-core
Rated operating voltage
DC 24 V 100% duty cycle
Rated current 110 mA (solenoid 100 mA, LED 10 mA : initial value)
Turn on voltage
Rated voltage × 85 % max. (at 20 °C 68 °F)
Turn off voltage
Rated voltage × 10 % min. (at 20 °C 68 °F)
Indicator
Green LED
SG-B1-□-G1: Approx. 220 g, SG-B1-□-G5: Approx. 600 g
Weight
Item
Operating condition
Designation Safety door switch with solenoid interlock
Series
SG-B1 series
Safety door switch
Safety door switch with solenoid interlock
Item
Notes: 1) Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured
between different contact circuits and between contact circuits and
LED or solenoid in the enclosure. When both SELV (safety extra low
voltage) or PELV (protective extra low voltage) circuits and other
circuits (such as 230 V AC circuits) are used for the solenoid power
and contact circuits at the same time, the SELV or PELV requirements
are not met any more.
2) The actuator locking strength is rated at 500 N of static load. Do not
apply a load higher than the rated value.
Do not apply a load higher than the rated value.
When a higher load is expected to work on the actuator, provide an
additional system consisting of another safety switch without lock (such
as the SG-A1 safety switch) or a sensor to detect door opening and
stop the machine.
SG-D1
19
SG-B1SERIES / SG-A1SERIES
Precautions for proper use
Safety door switch
Safety door switch with solenoid interlock
• This catalog is a guide to select a suitable product.
Be sure to read the instruction manual attached to the product
prior to its use.
SG-B1
SG-A1
Safety door switch with key
SG-B2
Enable grip switch
• In order to avoid electric shock or fire, turn the
power off before installation, removal, wire
connection, maintenance, or inspection of the
safety switch.
• If relays are used in the circuit between the safety
switch and the load, consider the danger and use
safety relays, since welding or sticking contacts of
standard relays may invalidate the functions of the
safety switch.
• Do not place a PLC in the circuit between the
safety switch and the load. Safety and security can
be endangered in the event of a malfunction of the
PLC.
• Do not disassemble or modify the safety switch,
otherwise a breakdown or an accident may occur.
• Do not install the actuator in a location where the
human body may come in contact. Otherwise injury
may occur.
• Magnet lock type is locked when energized, and
unlocked when de-energized. When energization is
interrupted due to wire disconnection or other
failures, the safety switch may be unlocked
causing possible danger to the operators. Magnet
lock type must not be used in applications where
locking is strictly required for safety. Perform a risk
assessment and determine whether solenoid lock
type is appropriate.
Both series
SG-C1
Emergency stop switch
SG-E1
Key selector switch
• Regardless of door types, do not use the safety switch as a door
stop. Install a mechanical door stop at the end of the door to
protect the safety switch against excessive force.
• Do not apply external force on the actuator while unlocking,
otherwise the actuator may not be unlocked.
• Do not apply excessive shock to the safety switch when opening or
closing the door. A shock to the safety switch exceeding 1,000 m/s2
may cause damage to the safety switch.
• If the operating atmosphere is contaminated, use a protective
cover to prevent the entry of foreign objects into the safety switch
through the actuator entry slots. Entry of a considerable amount
of foreign objects into the safety switch may affect the mechanism
of the safety switch and cause a malfunction.
• Do not store the safety switches in a dusty, humid, or organic-gas
atmosphere, or in an area subjected to direct sunlight.
• Use proprietary actuators only. When other actuators are used,
the safety switch may be damaged.
SG-B1 series
SG-D1
20
• The locking strength is rated at 500 N. Do not apply a load higher
than the rated value. When a higher load is expected, provide an
additional system consisting of another safety switch without lock
(such as the SG-A1 safety switch) or a sensor to detect door
opening and stop the machine.
• Regardless of door types, do not use the safety switch as a door
lock. Install a separate lock using a latch or other measures.
• While the solenoid is energized, the switch temperature rises
approximately 35 °C 95 °F above the ambient temperature (to
approximately 85 °C 185 °F while the ambient temperature is 50 °C
122 °F). Do not touch to prevent burns. If cables come into contact
with the switch, use heat-resistant cables.
• Bouncing will occur on the lock monitor contact during locking
and unlocking (reference value: 20 ms).
• Although the SG-K11 / SG-K12 / SG-K12A actuators alleviate
shock when the actuator enters a slot in the safety switch, make
sure that excessive shock is not applied. If the rubber bushings
become deformed or cracked, replace with new ones.
SG-A1 series
• Cover the unused actuator entry slot using the slot plug supplied
with the safety switch.
Minimum radius of hinged door
• When using the safety switch on hinged doors, refer to the
minimum radius of doors shown below. When using on doors with
small minimum radius, use the angle adjustable actuator (SG-K13
/ SG-K14).
Note: The values indicated in the figures below assume that there is no
6*.6*.$
mechanical
interference between the actuator and the safety switch
when the door is opened or closed. Because deviation or dislocation of
hinged doors may occur in actual applications, make sure of the
correct operation before installation.
0
0
LQLP
P XP
LQLP
XP
P UDG
'RRUKLQJH
When using the right-angle
actuator
/ SG-K12A)
P (SG-K12
LXV
P UDG
LQ
LXV 'RRUKLQJH
LQ
SG-B1 series
6*.6*.$
0
L
QLP
XP
P
P UD
G
LXV
LQ
0
L
QLP
X
P PU
P
DGLX
'RRUKLQJH
V
LQ
'RRUKLQJH
6*.6*.$
0
LQLP
P XP
P UDG
LXV
LQ
'RRUKLQJH
0
LQLP
XP
P
P UDG
LXV
LQ
'RRUKLQJH
SG-A1 series
6*.6*.$
SG-K12
0
L
QLP
X
SG-K12
P PU
M P DG
ini LX
23 mu V
0
m m raLQ
m
d
9 iu
M
ini .05 s
23 mu 5 i
n
0
m m ra
m
d
9. ius
05
SG-K12 5 in
0
L
QLP
X
P PU
MP
D
'RRUKLQJH 2 inim GLXV
30 um
m
m radLQ
9. ius
Door hinge
Mi
0
55
23 nimu
in
0
m m ra
m
9. dius
Door hinge
05
5
in
SG-K12
Min
16 imum
0 m ra
m dius
6.2
Min 99 in
i
16 mum
0 m ra
m dius
6.2
99
in
M
rad inim
16 ius um
0m
m
M 6.2
rad inimu 99 in
16 ius m
0m
m
6.2
99
in
'RRUKLQJH
Door hinge
Door hinge
Door hinge
Door hinge
Door hinge
Door hinge
SG-B1SERIES / SG-A1SERIES
Precautions for proper use
50 mm 1.969 in
Door hinge
Minim
adjustment
50 mm
9 in
Door hinge
the1.96actuator
• When the door hinge is on the extension line of
Label
SG-K13
mounting
surface: 70 mm 2.756 in SG-K13
• When the door hinge is on the extension
SG-K14line of the safety switch
SG-K14
surface: 50 mm 1.969 in
Minimum radius
SG-B1 series
50 mm 1.969 in
• Mount the safety switch on a fixed piece of machinery or guard
and the actuator on a hinged door. Avoid mounting both the
safety switch and actuator on a hinged door. Doing so may cause
equipment failure. For more information about how to mount the
devices, see the following diagram:
Minimum
radius
50 mm 1.969 in Door hinge
Door hinge
Horizontal
adjustment
s
adiu
mr
imu mm n
0
7 56 i
2.7
Door hinge
Min
s
adiu
mr
imu mm n
70 56 i
2.7
M
mm inimum ra
2.7 dius
56
in
SG-K13
ius
Minimum rad
Vertical
adjustment
50 mm
1.969 in
SG-K13
Door hinge
Label
Minimum radius
50 mm 1.969 in
Minimum
radius
50 mm 1.969 in Door hinge
Door hinge
Horizontal
ius
rad
SG-A1 series
adjustment
um
2.7 is on the extension line of the actuator 2mounting
SG-K13
s
SG-K13
SG-K14
SG-K13
SG-K14
70
.75
M2
mm inimum ra
2.7 dius
56
in
Label
Door hinge
Min
ra imu
mm dius m Door hinge
2M.i7
n
ra 5im6uin
70
mm dius m Door hinge
2.7
56
in
70
Label
s
radiu Door hinge
um
im
adjustment
Min 0 mm n
SG-K14
7 5a6diui s
Door hinge
Vertical
.7 r
2m
imu
adjustment
Min 0 mm n
Label
7 56 i
SG-K13
2.7
Minim
70
u
m
m
Door
hinge
rad
Label
m2
SG-K13
.75 ius
SG-K14
6 in
SG-K13
Vertical
SG-K14
Min
ra imu
mm dius m Door hinge
2M.7
in5
ra im6uin
70
mm dius m Door hinge
2.7
56
in
SG-K13
SG-K14
Label
Minimum Door hinge
radius
50 mm Min
1.9imu
69min
Door hinge
radius
50 mm 1.969 in
SG-K13
SG-K14
SG-K14
Minimum radius Door hinge
50 mm
1.969 in
Minimum radius Door
Label
hinge
50 mm
1.969 in
Label
Minimum Door hinge
radius
50 mm 1.9
69m in
Minimu
Door hinge
radius
50 mm 1.969 in
0WDSSHGKROH
Cables
• Do not fasten or loosen the gland at the bottom of the safety switch.
• When bending the cable during wiring, make sure that the cable
radius is kept at 30 mm 1.181 in minimum.
• When wiring, make sure that water or oil does not enter the cable.
• The solenoid has polarity. Make sure of the correct polarity when
wiring.
SG-E1
SG-B1 series
Actuator angle adjustment (vertical / horizontal)
• Using the angle adjustment screw (M3 hexagon-socket-head
screw), the actuator angle can be adjusted. (refer to the
dimensions on page 24)
Adjustable angle: 0 to 20°
• The larger the adjusted angle of the actuator, the smaller the
applicable radius of the door opening. After installing the actuator,
open the door. Then adjust the actuator so that its edge can be
inserted properly into the actuator entry slot of the safety switch.
• After adjusting the actuator angle, apply Loctite to the adjustment
screw so that the screw will not move.
SG-C1
Key selector switch
SG-K14
SG-K13
1.969 in
adjustment
Vertical
adjustment
SG-K13
SG-B2
+LQJHGGRRU
70
Horizontal
Vertical
adjustment Minimum radius Door hinge
50 mm
Horizontal
1.969 in
Label
adjustment Minimum radius Door
hinge
50 mm
Safety switch: 1.0 to 1.5 N·m (Three M4 screws)*
Actuator: 1.0 to 1.5 N·m (Two M4 screws)*
*The above recommended tightening torques of the mounting
screws are the values confirmed with hexagon-socket-head bolts.
When other screws are used and tightened to a smaller torque,
make sure that the screws do not become loose after mounting.
• Mounting bolts must be provided by the users.
• To avoid unauthorized or unintended removal of the safety switch
and the actuator, it is recommended that the safety switch and
actuator are installed in a secure manner, for example using
special screws or welding the screws.
• When installing the SG-K12A actuator, use the mounting plate
(supplied with the actuator) on the hinged door, and mount tightly
0VFUHZV
using two M4 screws.
The mounting plate has orientation.
0RXQWLQJSODWH
Do not lose the mounting plate.
$FFHVVRU\
Adequate performance cannot
be obtained without the plate as
5XEEHUEXVKLQJ
the actuator may fall off the door.
Emergency stop switch
radiu Door hinge
Horizontal
imum
adjustment Min 0 mm ins
7 5ra6diu Door hinge
SG-K14
7
Horizontal
im2u.m
Label
adjustment Min 0 mm in
7
6
Recommended tightening torque for mounting screws
Enable grip switch
SG-K14
SG-K14
(Application on hinged doors)
Door hinge
Horizontal Minimum radius
Door hinge
50 mm 1.969 in
adjustment
Door stop
(Application on sliding doors)
Note: W
hen mounting the actuator, make sure that the
actuator
enters the slot in the correct direction,
as shown on the right figure.
M
mm inimum rad
2.7 ius
56
in
70
Door hinge
SG-B1
SG-A1
Latch
Label
SG-K14
70
SG-B1 series
Safety switch
Door hinge
Min
SG-K13
SG-K14
SG-K11
Actuator
Safety door switch with key
SG-K13
Vertical
adjustment
SG-K12A
Actuator
Door
&RQGXLW
GLXV
0LQLPXPUD
LQ
PP
0LQLP
X
P UDGLXV P
P
LQ
Minimum
adjustment
Mounting
Safety door switch
Safety door switch with solenoid interlock
When using the (SG-K13 / SG-K14) angle adjustable
(vertical
/ horizontal)
actuatorVertical
um radius
Horizontal
radius
&RQGXLW
SG-D1
SG-A1 series
Conduit
us
di in
ra 75
m
5
.
u
im m 1
in
M 0m
4
(Unit: mm in)
21
SG-B1SERIES / SG-A1SERIES
Dimensions (Unit: mm in)
+ROHIRUPDQXDOXQORFNLQJ
¡¡UHIHUHQFH
WR
WR
0DQXDOXQORFNLQJNH\
5
&
&
+ROHIRUPDQXDOXQORFNLQJ
¡¡UHIHUHQFH
KROHVIRU0VFUHZ
¡¡RU
0WDSSHGKROH
SG-B2
¡
5
Safety door switch with key
Ƒ
KROHVIRU0VFUHZ
¡¡RU0WDSSHGKROH
¡
SG-B1
SG-A1
Mounting hole layout
Safety door switch
Safety door switch with solenoid interlock
SG-B1□ Safety door switch with solenoid interlock
Enable grip switch
WR
WR
Note 1: Drill mounting holes so that they are properly aligned for the orientation in which the safety switch will be used.
SG-E1
Actuator stop (Note 2)
(Accessory)
(25 0.984)
22.6 ±1 0.089 ±0.039
48.8 1.921
(14 0.551)
When using the angle adjustable
actuator (horizontal / vertical)
(SG-K13 / SG-K14)
0.8 0.031
0.089 ±0.039
50.8 2.000
0.8 0.031
22.6 ±1
0.8 0.031
(5 0.197)
When using the right-angle actuator
(SG-K12 / SG-K12A)
(14 0.551)
Emergency stop switch
(12.6 ±1 0.496 ±0.039)
(6.2 0.244)
When using straight actuator (SG-K11)
(42 1.654)(Note 3)
SG-C1
Actuator stop
(Note 2)
(Accessory)
Actuator stop (Note 2)
(Accessory)
Key selector switch
Notes: 2) The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted.
3) 41.4 1.63 when using SG-K12
*The tensile strength of the SG-K12 actuator is 100N. If an excessive tensile force is applied, the actuator may fall off the door.
When a tensile force exceeding 100N is expected, use the SG-K12A actuator with a plate.
Actuator mounting reference position
As shown in the figure on the right, the mounting reference position of
the actuator when inserted in the safety switch is:
The actuator stop on the actuator lightly touches the safety switch.
*The actuator stop is used to adjust the actuator position. Remove the
actuator stop after the actuator position is mounted.
6DIHW\VZLWFK
$FWXDWRUVWRS
$FFHVVRU\
6*.
$FWXDWRU
22
'RRUVWRS
SG-D1
'RRUVWRS
SG-B1SERIES / SG-A1SERIES
Dimensions (Unit: mm in)
SG-A1□ Safety door switch
5
5
SG-B2
$FWXDWRUVWRS1RWH
$FFHVVRU\
Enable grip switch
When using the angle adjustable
actuator (horizontal / vertical)
(SG-K13 / SG-K14)
When using the right-angle actuator
(SG-K12)
When using straight actuator (SG-K11)
¡
¡
SG-B1
SG-A1
Safety door switch with key
Note 1: Plug the unused
actuator entry slot using
the plug supplied with
the switch.
7KHVDIHW\VZLWFKFDQEH
PRXQWHGLQWZRGLUHFWLRQV
KROHVIRU0VFUHZ
6ORWSOXJ1RWH
$FFHVVRU\
WRWR
¡¡RU0WDSSHG
Safety door switch
Safety door switch with solenoid interlock
Mounting hole layout
$FWXDWRUVWRS1RWH
$FFHVVRU\
$FWXDWRUVWRS1RWH
$FFHVVRU\
Note 2: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted.
SG-C1
:KHQPRXQWHG
5XEEHUEXVKLQJ
¡
¡
:KHQPRXQWHG
¡¡
5XEEHUEXVKLQJ
SG-E1
Key selector switch
$FWXDWRUVWRS1RWH
$FFHVVRU\
¡¡
* The tensile strength of the SG-K12 actuator is 100N. If an excessive tensile force is applied, the actuator
may fall off the door.
When a tensile force exceeding 100N is expected, use the SG-K12A actuator with a plate.
:KHQPRXQWHG
¡
:KHQPRXQWHG
¡
Right-angle actuator (SG-K12)
Straight actuator (SG-K11)
Emergency stop switch
SG-K11 / SG-K12 Actuator
$FWXDWRUVWRS1RWH
$FFHVVRU\
Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted.
Actuator mounting hole layout (Straight actuator, right-angle actuator)
SG-D1
KROHVIRU0VFUHZ
¡¡RU0WDSSHG
23
SG-B1SERIES / SG-A1SERIES
Dimensions (Unit: mm in)
Safety door switch
Safety door switch with solenoid interlock
SG-K13 / SG-K14 Actuator
Horizontal / vertical angle adjustable
actuators (SG-K14)
Horizontal / vertical angle adjustable actuators
(SG-K13)
* The SG-K14 differs from the SG-K13 in
that the direction in which the metal parts
on the tip of the actuator are embedded is
reversed by 180°.
0.8 0.031
Orienting
insert
3.5 0.138
1.2 0.047
(Horizontal adjustment)
(Horizontal adjustment)
Angle adjustment
(M3 hexagon-socket-head screw)
The orientation of actuator adjustment
(horizontal / vertical) can be changed
using the orienting insert (white plastic)
installed on the back of the actuator.
Do not lose the mounting plate.
Orienting insert
Safety door switch with key
20°
20°
SG-B1
SG-A1
Changes in the orientation of
adjustment for angle adjustable
(horizontal / vertical) actuators
Angle adjustment
(M3 hexagon-socket-head screw)
13
0.512 28.2 1.110
20°
34 1.339
20°
Actuator stop (Note)
(Accessory)
SG-B2
Angle adjustment
(M3 hexagon-socket-head screw)
Actuator stop (Note)
(Accessory)
16.8 0.661
Orienting
insert
(Vertical adjustment)
2 0.079
25 0.984
7.5 0.295
5.5 0.217
Vertical
adjustment
Horizontal
adjustment
R2
(M .1 R
Angle adjustment
4 h 0.0
2.5 0.098 (M3 hexagon-socket-head screw)
ole 83
s)
15 0.591
Enable grip switch
* The base is made of glass-reinforced PA66 (66 nylon). Angle adjustment screws are stainless steel (SUS).
When using adhesive on screws, take material compatibility into consideration.
Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted.
Actuator mounting hole layout (horizontal / vertical angle adjustable actuators)
25 0.984
SG-C1
2-holes for M4 screw
(ø4.3 ø0.169 or M4 tapped)
Emergency stop switch
24
0.945
15
9
0.591 0.354
ø10 ø0.394
3 0.118
• Manual unlocking key (Accessory: plastic)
SG-E1
18 0.709
(24.5 0.965)
Key selector switch
SG-D1
24
6.5 0.256
Vertical
adjustment
SG-B2
SERIES
Safety door switch with key
Contact configuration / Operating patterns
: Closed
Status 2
• Door closed
• Machine ready to
operate
Safety switch status
Status 3
• Door closed
• Machine cannot
be operated
Rear manual unlock
• Door open
• Machine cannot
be operated
Safety door switch
Safety door switch with solenoid interlock
Status 1
: Open
• Door closed
• Machine cannot
be operated
3UHVV
Door status
3UHVVUHDUXQORFNLQJ
EXWWRQ1RWH
SG-B1
SG-A1
Door
SG-B2-K2□C-5
11
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor
Monitor circuit
circuit ::
Monitor circuit
circuit ::
Monitor
Monitor circuit :
/2&.
81/2&.
/2&.
81/2&.
/2&.
81/2&.
/2&.
81/2&.
• Closed (locked)
12
11
23
12
24
12 13
12 24
23
24
Monitor circuit :
LOCK
UNLOCK Monitor circuit
LOCK4 1
UNLOCK
42
LOCK45 31
UNLOCK
54 42
54 31
54 42
53
54
• Closed (unlocked)
• Open
• Closed (unlocked)
(door closed)
11-12
Monitor circuit
(door open)
23-24
Monitor circuit
(locked)
41-42
SG-B2
Monitor circuit
(unlocked)
53-54
SG-B2-K2□D-5
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor
Monitor circuit
circuit ::
Monitor circuit
circuit ::
Monitor
Monitor circuit :
Enable grip switch
Monitor circuit
(door closed)
11-12
11
12
21 11
21 22
21 1
21 2
21
22
Monitor circuit :
SG-B2-K2□D-L5
41
42
54 11
54 22
54 1
54 2
51
52
Monitor circuit
(door closed)
21-22
Monitor circuit
(locked)
41-42
Monitor circuit
(locked)
51-52
SG-C1
Monitor circuit
(door closed)
11-12
Emergency stop switch
Model No. and contact configuration
Safety door switch with key
Circuit diagram (Example: SG-B2-K2□D-L5)
Monitor circuit
(door closed)
21-22
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor circuit :
Monitor
Monitor circuit
circuit ::
11
12
21 11
21 22
21 1
21 2
Monitor circuit
circuit ::
Monitor
41
42
45 11
45 22
54 1
54 2
Monitor circuit
(locked)
41-42
Monitor circuit
(locked)
51-52
: Contact ON (closed)
: Contact OFF (opened)
• Operation characteristics
(reference)
0 (Actuator mounting reference position)
Approx. 3.3 0.130 (Lock)
SG-B2-K2□C-5
Approx. 5.3 0.209
Approx. 6.9 0.272
Monitor circuit (11-12)
Monitor circuit (23-24)
Monitor circuit (41-42)
Monitor circuit (53-54)
(Actuator completely inserted)
Approx. 26.4 1.039
(Travel: mm in)
(Actuator pulled out)
SG-B2-K2□D-5
SG-B2-K2□D-L5
Monitor circuit (11-12)
Monitor circuit (21-22)
Monitor circuit (41-42)
Monitor circuit (51-52)
SG-E1
Key selector switch
2 1operator
2 2 is confined in a hazardous area, the actuator can be unlocked manually by pressing the rear unlocking button, which should be
MonitorWhen
circuit : the
Notes: 1)
51
52
easily by the operator.
Monitoraccessed
circuit :
2) The above contact configuration shows the status when the actuator is inserted and the switch is locked.
3) Monitor circuit: Sends monitoring signals of protective door open / closed status or protective door lock / unlock status.
0 (Actuator mounting reference position)
Approx. 3.3 0.130 (Lock)
Approx. 5.3 0.209
Approx. 6.9 0.272 Approx. 26.4 1.039
(Travel: mm in)
(Actuator completely inserted)
(Actuator pulled out)
SG-D1
• The characteristics show the contact status when the actuator enters an entry slot of an safety switch.
• The characteristics shown in the chart above are of the SG-K21 actuator. For the others actuator, add 1.3 mm 0.051 in.
When connecting the SG-B2 series to a safety circuit, connect the door monitor circuits (11-12)
(41-42, 51-52) in series. (GS-ET-19)
and the lock monitor circuits
25
SG-B2 SERIES
Specifications
SG-B1
SG-A1
Designation
Series
Safety door switch with key
SG-B2 series
• This catalog is a guide to select a suitable product.
Be sure to read the instruction manual attached to the product
prior to its use.
• In order to avoid electric shock or fire, turn the power
off before installation, removal, wire connection,
maintenance, or inspection of the safety switch.
• If relays are used in the circuit between the safety
switch and the load, consider the danger and use
safety relays, since welding or sticking contacts of
standard relays may invalidate the functions of the
safety switch.
• Do not place a PLC in the circuit between the
safety switch and the load. Safety and security can
be endangered in the event of a malfunction of the
PLC.
• Do not disassemble or modify the safety switch,
otherwise a breakdown or an accident may occur.
• Do not install the actuator in a location where the
human body may come in contact. Otherwise injury
may occur.
SG-B2
Enable grip switch
SG-C1
Emergency stop switch
SG-E1
Key selector switch
Key
DC
AC
Safety door switch with key
Applicable
EN 1088, IEC 60947-5-1, EN 60947-5-1,
standards
GS-ET-19, UL 508, CSA C22.2 No.14
Standards for use
IEC 60204-1, EN 60204-1
Applicable
Machinery directive (2006/42/EC)
directives
Low voltage directive (2006/95/EC)
Ambient
-25 to +70 °C -13 to +158 °F (No dew condensation or icing allowed)
temperature Storage: -40 to +80 °C -40 to +176 °F
Ambient humidity
45 to 85 % RH
Pollution degree
3 (Inside 2)
Altitude
2,000 m 6,561.68 ft max.
Impulse withstand
2.5 kV
voltage (Uimp)
Rated insulation
250 V (Note 1)
voltage (Ui)
2.5 A
Ambient temperature:
Thermal current
-25 to +60 °C -13 to +140 °F: 2.5 A max.
(Ith)
+60 to +65 °C +140 to +149 °F: 1.5 A max.
+65 to +70 °C +149 to +158 °F: 1.0 A max.
Ie
Ue 30 V 125 V 250 V
Rated operational
Resistive load (AC-12)
2.5 A 1.5 A
voltage (Ue) /
Inductive load (AC-15)
1.5 A 0.75 A
Rated operational
Resistive
load
(DC-12)
2.5
A
1.1 A 0.55 A
current (Ie)
Inductive load (DC-13) 2.3 A 0.55 A 0.27 A
Operating frequency
900 operations/hour
Actuator operating speed
0.05 to 1.0 m/sec.
2,000,000
B10d
(ISO 13849-1 Annex C Table C.1)
Mechanical
1,000,000 operations min. (GS-ET-19)
durability
Rear unlocking button: 3,000 operations min. (Type SG-B2-□-L5)
100,000 operations min. (AC-12, 250 V 1 A)
Electrical
1,000,000 operations min. (AC/DC 24 V 100 mA)
durability
(900 operations/hour)
Electric shock
Class II (IEC 61140) (Note 2), (double-insulated)
protection class
1,400 N min. (GS-ET-19) (Note 3)
Interlock force
(500 N min. : SG-K24 actuator)
Direct opening
11 mm 0.433 in min. (actuator: SG-K21)
travel
12 mm 0.472 in min. (for other actuators)
Direct opening force
80 N min.
Contact resistance 700 mΩ max. (initial value, 5 m 16.404 ft cable)
Protection
IP 65 (IEC 60529)
Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2
Vibration
Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
resistance
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
Conditional
50 A (250 V)
short-circuit current
Short-circuit
Use 250 V / 10 A fast acting type fuse
protective device
Material
Enclosure: PA66
Cable
UL style 2464, No.22 AWG 12-core
Operating
2 positions
specifications
Mechanical
100,000 operations min.
durability
Key operating
10,000 operations min.
durability
Key tensile
1.0 N·m min.
strength
Direct opening
0.6 N·m min.
force
Direct opening
60° min.
degree
SG-B2-□-5: Approx. 680 g, SG-B2-□-L5: Approx. 700 g
Weight
Operating condition
Safety door switch
Safety door switch with solenoid interlock
Item
Precautions for proper use
SG-D1
26
Notes: 1) Ratings approved by UL, c-UL: 125 V
2) Basic insulation of 2.5 kV impulse withstand voltage is ensured
between different contact circuits.
When both SELV (safety extra low voltage) or PELV (protective extra
low voltage) circuits and other circuits (such as 230 V AC circuits)
are used for the solenoid power and contact circuits at the same
time, the SELV or PELV requirements are not met any more.
3) The actuator locking strength is rated at 1,400 N of static load. Do not
apply a load higher than the rated value. When a higher load is
expected to work on the actuator, provide an additional system
consisting of another safety switch without lock (such as the SG-A1
safety switch) or a sensor to detect door opening and stop the machine.
• Regardless of door types, do not use the safety switch as a door
stop. Install a mechanical door stop at the end of the door to
protect the safety switch against excessive force.
• Do not apply excessive shock to the safety switch when opening or
closing the door. A shock to the safety switch exceeding 1,000 m/s2
may cause damage to the safety switch.
• If the operating atmosphere is contaminated, use a protective
cover to prevent the entry of foreign objects into the safety switch
through the actuator entry slots. Entry of a considerable amount
of foreign objects into the safety switch may affect the mechanism
of the safety switch and cause a malfunction.
• Cover the unused actuator entry slot using the slot plug supplied
with the safety switch.
• Do not store the safety switches in a dusty, humid, or organic-gas
atmosphere, or in an area subjected to direct sunlight.
• Use proprietary actuators only. When other actuators are used,
the safety switch may be damaged.
Do not cut, machine, or otherwise modify actuators. Doing so
may cause equipment failure.
• Do not open the lid of the safety switch. Loosening the screws
may damage the safety switch.
• The locking strength is rated at 1,400 N. Do not apply a load
higher than the rated value. When a higher load is expected,
provide an additional system consisting of another safety switch
without lock or a sensor to detect door opening and stop the
machine.
• Regardless of door types, do not use the safety switch as a door
lock. Install a separate lock using a latch or other measures.
• Although the SG-K21A / SG-K22A actuators alleviate the shock
when the actuator enters the slot on the safety switch, make sure
that excessive shock is not applied. If the rubber bushings
become deformed or cracked, replace with new ones.
SG-B2 SERIES
Precautions for proper use
• Do not mount the safety switch facing down as shown in the
figure below. Otherwise, the key may fall off due to shock.
Actuator angle adjustment (vertical / horizontal)
Cables
When using the angle adjustable actuator (SG-K24)
(Unit: mm in)
M
i
70 nim
m um
m
2. radi
75 us
6
in
Door hinge
(55.5 2.185)
M
in
70 imu
m m
m
r
2. adiu
75
6 s
in
(36.2 1.425)
Door hinge
(231 9.094)
(161 6.339)
us in
adi
m r 7.480
imu
Min 0 mm
19
dius in
m ra 93
imu 6.6
Min mm
0
17
Door hinge
Safety switch
mounting hole
(35 1.374)
(Unit: mm in)
Mi
n
50 imu
Door
m m ra
m
d
1. ius hinge
96
9
in
(36.2 1.425)
Mounting
(Horizontal adjustment)
Safety switch
mounting hole
(38 1.496)
SG-C1
(Vertical adjustment)
• Mount the safety switch on a fixed piece of machinery or guard
and the actuator on a hinged door.
Avoid mounting both the safety switch and actuator on a hinged
door. Doing
so may cause equipment
failure. For more information
M
M
in
in
im to mount the devices,
im the following diagram:
70 see
about70 how
u
m um
m
2. radi
75 us
6
in
m
m
m
ra
.7 dius
(Application
Door hinge on sliding2doors)
5
6
(55.5 Door
2.185)
SG-K21
Actuator
SG-B2
series
Safety
switch
Hook
Door stop
in
Emergency stop switch
s
adiu 6 in
m r .23
imu 10
Min mm
0
26
s in
adiu
m r 9.055
imu
Min mm
230
(Unit: mm in)
(55.5 2.185)
(Vertical adjustment)
Mi
50 nimum
Door
mm ra
d
hinge
1.9 ius
69
in (36.2 1.425)
(40.3 1.587)
SG-B2
Enable grip switch
(Horizontal adjustment)
When using the right-angle actuator (SG-K22)
Door hinge
Door
hinge
Note: Because deviation or dislocation of hinged doors may occur in actual
applications, make sure of the correct operation before installation.
Safety switch
mounting hole
Safety switch
mounting hole
(58 2.283)
Gland
(Vertical adjustment)
Safety switch
mounting hole
(58 2.283)
ius
rad 1 in
um .18
iM nim m 1
m
30
(48 1.890)
(Horizontal adjustment)
When using the safety switch on hinged doors, refer to the
minimum radius of doors shown below. When using on doors with
small minimum radius, use the angle adjustable actuator (SG-K24).
(41.5 1.634)
Safety door switch with key
Lid
Minimum radius of hinged door
Door hinge
SG-B1
SG-A1
Safety switch
mounting hole
(38 1.496)
• When the door hinge is on the extension
line of the actuator
Mi
n
Min
i
mounting 5surface:
70Door
mm 2.756 in 50 mimum
0 m mum
Door
m radi
ad
m rhinge
hinge
hinge
us of
• When the door
is on the extension1.9line
the safety switch
1.9 ius
69
69
i
i
n (36.2 1.425)
surface: 50 mm 1.969
n (36.2 in
1.425)
Safety door switch
Safety door switch with solenoid interlock
• Do not fasten or loosen the gland
at the bottom of the safety switch.
• When bending the cable during
wiring, make sure that the cable
radius is kept at 30 mm 1.181 in
minimum.
• When wiring, make sure that
water or oil does not enter the
cable.
• Do not open the lid of the safety
switch. Otherwise the safety
switch will be damaged.
• Using the angle adjustment screw (M3 hexagon-socket-head
screw), the actuator angle can be adjusted. (refer to the
dimensions on page 29)
Adjustable angle: 0 to 20°
• The larger the adjusted angle of the actuator, the smaller the
applicable radius of the door opening. After installing the actuator,
open the door. Then adjust the actuator so that its edge can be
inserted properly into the actuator entry slot of the safety switch.
• After adjusting the actuator angle, apply Loctite to the adjustment
(Horizontal adjustment)
(Vertical adjustment)
screw so that the screw will not move.
Door
hinge
(55.5 2.185)
Application on
hinged doors
SG-K22
Actuator
SG-K21S
Actuator
Door
SG-E1
(48.2 1.898)
Door hinge
(231 9.094)
s
adiu in
m r 236
imu 10.
Min mm
260
s
mm
adiu
m r : 230 5 in
5
imu
Min 12 mm in: 9.0 10 mm in
ters 0.472 mm: 3 2.205
20 in: 1
ters 87
Cen 0.7
Cen
Door hinge
Safety switch
mounting hole
(47 1.850)
(36.2 1.425)
Safety switch
mounting hole
Door hinge
(35 1.374)
(111 4.370)
s
adiu in
m r 5.512
imu
Min 0 mm
14
s
mm
adiu
m r : 120 24 in
imu
m 7
Min 12 m in: 4. 70 mm in
ters 0.472 m: 1 .693
m 6
20 in:
ters .787
Cen 0
Cen
Door hinge
SG-B2 series
Safety switch
Recommended tightening torque for mounting screws
• Recommended screw tightening torque
For mounting the safety switch (M4 screw) (Note 1)
(Unit: mm in)
(Unit: mm in)
Key selector switch
When using the right-angle actuator (with rubber bushings) (SG-K22A)
For mounting the actuator
(SG-K21 : Two M4 screws) (Note 1)
(SG-K21A / SG-K22A : Two M4 screws) (Note 1, 2)
(SG-K21S : M5 screw) (Note 1)
(SG-K22 : Two M4 phillips screws)
(SG-K24 : Two M4 screws) (Note 1)
For mounting the SG-B2 head (M3)
For mounting the manual rear unlocking button (M3 screw with washers)
Notes: 1) The above recommended tightening torques of the
mounting screws are the values confirmed with
hexagon-socket-head bolts. When other screws are
used and tightened to a smaller torque, make sure
that the screws do not come loose after mounting.
2) In the case of SG-K21A or SG-K22A, using two M4
screws and two attached washers, fasten the
actuator securely on the door.
Screw tightening torque
1.8 to 2.2 N·m
1.8 to 2.2 N·m
1.0 to 1.5 N·m
4.5 to 5.5 N·m
0.8 to 1.2 N·m
1.0 to 1.5 N·m
0.9 to 1.1 N·m
0.5 to 0.7 N·m
SG-D1
M4 screw
Washer
Rubber bushing
Hinged door
M4 tapped hole
27
SG-B2 SERIES
Dimensions (Unit: mm in)
SG-B2-K2□-5 Door switch
Safety door switch
Safety door switch with solenoid interlock
(6.3 0.248)
*Actuator center position
R
1 0.08
0.039 7
35 1.378
(6.3 0.248)
0.236 ±0.039 *
20
0.787
4-holes for M4
ø4.3 ø0.169 or
M4 tapped hole
6 ±1
106 4.173
145.7 5.736
76.7 3.02
53.7 2.114
5 0.197
33 1.299
40 1.575
20
0.787
Safety door switch with key
20 to 22
0.787 to 0.866
Safety switch mounting hole layout
106 4.173
R2
.2
20 0.787
36.2 1.425
33 1.299
40 1.575
1
0.039
Actuator
Actuator stop
(Accessory)
1
0.039
20 0.787
35 1.378
20 0.787
73.2 2.882
28 1.102
2R
R2.
106 4.173
145.7 5.736
76.7 3.020
53.7 2.114
11 ±1 0.433 ±0.039 *
5 0.197
Slot plug
(Note1)
(Accessory)
RP
41 1.614 26.4 1.039
5.2 0.205
6.2 0.244
0.0
87
1
0.039
0.9
5ø
ø2
36.2 1.425
Actuator
Actuator stop
(Accessory)
SG-B1
SG-A1
73.2 2.882
28 1.102
20 0.787
□30 □1.181
RP
26.4 1.039 42.2 1.661
6.2 0.244
5.2 0.205
84
When using horizontal mounting / straight actuator (SG-K21)
SG-C1
Operation key (Accessory)
106 4.173
145.7 5.736
35 1.378
20 0.787
20
29.6 1.165
1
0.039
36.2 1.425
1
0.039
87
35 1.378
73.2 2.882
Actuator
Actuator cover
Actuator stop
(Accessory)
(6.3 0.248)
(6.3 0.248)
4-holes for M4
ø4.3 ø0.169 or
M4 tapped hole
*Actuator center position
7.6 ±1 0.299 ±0.039 *
20
0.787
33 1.299
40 1.575
106 4.173
76.7 3.02
53.7 2.114
5 0.197
20
0.787
33 1.299
40 1.575
20 to 22
0.787 to 0.866
Safety switch mounting hole layout
5 0.197
76.7 3.020
53.7 2.114
12.6 ±1 0.496 ±0.039 *
106 4.173
145.7 5.736
1.8
0.071
16 0.630
Enable grip switch
38 1.496
0.0
20 0.787
36.2 1.425
Actuator cover
Actuator
Actuator stop
(Accessory)
Slot plug (Note1)
(Accessory)
RP
40.3 1.587 27.7 1.091
1
0.039
29.6 1.165
20 0.787
SG-B2
□30 □1.181
ø2
5ø
73.2 2.882
R2.
2R
0.9
84
RP
27.7 1.091 41.5 1.634
R2
.2
R
1 0.0
0.039 87
When using vertical mounting / straight actuator (SG-K22)
Notes: 1) Plug the unused actuator entry slot using the plug supplied with the switch.
2) When mounting the safety switch, be sure to conform to the mounting hole dimensions and secure in place with four screws.
Emergency stop switch
SG-B2-K□-L5 Door switch (rear unlocking button type)
6DIHW\VZLWFKPRXQWLQJKROHOD\RXW
0
¡¡ XQORFNLQJ
5HDU Q
EXWWR
UHQFH
5HIH
Actuator mounting reference position
As shown in the figure on the right, the mounting reference position
of the actuator when inserted in the safety switch is:
The actuator stop on the actuator lightly touches the safety switch.
* The actuator stop is used to adjust the actuator position. Remove
the actuator stop after the actuator position is mounted.
28
Note: Plug the unused actuator entry slot using the plug supplied with the
switch.
5HDUXQORFNLQJEXWWRQ
SG-D1
¡¡
With the mounting hole dimension, the rear unlocking button rod
does not touch the hole even when the safety switch moves
sideways.
Safety switch
WR
WR
5HDUXQORFNLQJEXWWRQ
$FFHVVRU\
Key selector switch
$FWXDWRU
6 < X < 23 mm 0.236 < X < 0.906 in : Not mountable
23 ≤ X ≤ 53 mm 0.906 ≤ X ≤ 2.087 in : U
se a rear unlocking button
kit. (refer to page 11, 30)
* The mounting part is a frame or a panel that the product is
mounted on.
SG-E1
Mounting part* thickness (X):1 to 6 mm 0.039 to 0.236 in
5
5
¡
ƑƑ
¡
53
When using horizontal mounting / straight actuator (SG-K21)
KROHVIRU0
¡¡RU
0WDSSHGKROH
Door stop
Safety switch
Actuator stop
(Accessory)
Actuator stop
(Accessory)
Actuator cover
Actuator
SG-K21
Door stop
Actuator SG-K22
SG-B2 SERIES
Dimensions (Unit: mm in)
SG-K2□ Actuator
4-R Actuator stop (Accessory) (Note 1)
2 0.079
10
0.394
0.8 0.031
Actuator stop
(Accessory) (Note)
20 0.787
2-M4 thread
20 0.787
7.2 0.283
15 0.591
30 1.181
28 1.102
26 1.024
4.5 0.177
Actuator mounting hole layout
(Straight / Right-angle actuator)
6.4 0.252
7.2 0.283
.4
-ø4
3
.17
ø0
1.6 0.063
2
2 0.079
7
8
0.0
R
33 1.299
2 0.079
15 0.591
28 1.102
20 0.787
5.2 0.205
2.2
Right-angle actuator (SG-K22)
32.4 1.276
(6 0.236)
0.8 0.031
6.2 0.244
Safety door switch
Safety door switch with solenoid interlock
Straight actuator (SG-K21)
SG-B1
SG-A1
Safety door switch with key
Actuator cover
2 0.079
12 0.472
* Mounting pitch can be widened to 20 mm
0.787 in by moving the rubber bushings.
Rubber bushing
(20 0.787)
12 0.472
.16
9
ø0
* When the mounting pitch is 12 mm
0.472 in (factory setting), the
actuator has movement flexibility to
the directions shown in Ⓐ and Ⓑ .
* When the mounting pitch is 20 mm
0.787 in, the actuator has
movement flexibility to the directions
shown in Ⓑ. Side the rubber
cushions together with the screws.
4.3
0.8 0.031
When mounted
(5 0.197)
Ⓑ
2-ø9 ø0.354
Rubber bushing Washer (Accessory)
0.8 0.031
Ⓑ
Actuator stop (Accessory) (Note)
SG-B2
Enable grip switch
When
mounted
(5 0.197)
2-M4 thread
)
Ⓐ
2-ø
(
When mounted (39.7 1.563)
0.8 0.031
15 0.591
Actuator mounting hole layout
Straight actuator with rubber bushings,
Right-angle actuator with rubber bushings
When mounted
(11.2 0.441)
2 0.079
15 0.591
30 1.181
(20 0.787)
12 0.472
* Mounting pitch is set to 12 mm 0.472 in in
factory. When setting the mounting pitch to
20 mm 0.787 in, widen the pitch of rubber
cushions to 20 mm 0.787 in.
* The actuator has movement flexibility to the
directions shown in Ⓑ.
Actuator stop
(Accessory) (Note)
Washer (Accessory)
2-ø10 ø0.394
Right-angle actuator with rubber bushings (SG-K22A)
2-ø10
ø0.394
43.8 1.724
15.3 0.602 0.8 0.031
15.8 0.622
2-ø9 8.5 0.335
ø0.354
7.3 0.287
4.3
ø0.
169
30 1.181
Straight actuator with rubber bushings (SG-K21A)
2-ø
Slide actuator (SG-K21S)
14 0.551
2-ø5.2
51 2.008
6-M5 thread 32.5 1.280
35 1.378
6
0.236
Actuator material:
Stainless steel (SUS)
Thickness: 2.5 0.098
34 1.339
30.5 1.201
16 0.630
15 0.591
18 (40 1.575)
30.7 1.209 0.709 3 0.118
75 2.953
SG-C1
Emergency stop switch
2.5
0.098
Actuator mounting hole layout
5
ø0.20
34 1.339
48.5 1.909
56 2.205
5 37.5 1.476
0.197 19 0.748
8-R2.6 R0.1
02
26.5 1.043
2.5 13 0.512
0.098
Body material: Stainless steel (SUS)
Horizontal / Vertical angle adjustable actuators (SG-K24)
3
Horizontal 0.118
adjustment
20°
15 0.591
7
0.276
18.5 0.728 29 1.142
1 0.039
(Vertical adjustment)
Orienting
insert
Actuator stop
(Accessory) (Note)
R
(Ho 2.1 R0.
le fo 083
r M4
)
3.6 0.142
Changes in the orientation of adjustment for angle
adjustable (vertical / horizontal) actuators
The orientation of adjustment of angle adjustable (vertical / horizontal)
actuators is determined by the position in which the orienting insert (white
plastic) is installed on the back of the actuator.
Install the insert according to the desired orientation of adjustment.
Exercise care not to lose the orienting insert. The actuator will not operate
properly without the orienting insert.
SG-E1
Key selector switch
49 1.929
Orienting
insert
23 0.906
26 1.024
38 1.496
Angle adjustable screw
(M3 hexagon-socket-head screw)
Actuator stop
(Accessory) (Note)
Actuator mounting hole layout
horizontal / vertical angle adjustable
actuators
2-M4 thread
38 1.496
SG-PH2 Padlock hasp (Optional)
0.8 0.031
2-R
Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop
after the actuator position is mounted.
4R
0.1
57
ø8
2-
15
SG-D1
ø
3
0.
28 1.102
16.5
0.650
20°
2
0.079
Angle adjustable screw
(M3 hexagon-socket-head screw)
8
0.315
60 2.362
29
SG-B2 SERIES
Dimensions (Unit: mm in)
10 0.394
.13
0
When installing the SG-B2-K2□-L5
(rear unlocking button type), provide a rear
unlocking button a hole on the MS-SG21.
3.3
R0
(40 1.575)
13.4 0.528
4-M4 thread
Material: Anodized aluminum A6063
Weight: Approx. 180 g
20 to 22
0.787 to 0.866
4-M4 thread
C3
4- .118
C0
22 0.866
SG-B2
ø
fo 18
bu r re ø0
tto ar .70
n u 9
(N nlo ho
ot ck le
e) in
g
106 4.173
187 7.362
170 6.693
Safety door switch with key
6.4
4-R 252
R0.
(187 7.362)
21 0.827
ø18 ø0.709 hole
for rear unlocking
button (Note)
106 4.173
read
21
0.827
64.1 2.524
4 th
Safety switch mounting
hole layout
4-R
40 1.575
(13.4 0.528)
4-M
SG-B1
SG-A1
Mounting plate hole layout
42.2 1.661
50.7 1.996
2-12.8 0.504
2-6.6 0.260
6 0.236
Safety door switch
Safety door switch with solenoid interlock
MS-SG21 Mounting plate (Optional)
Note: With the mounting hole dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways.
Enable grip switch
MS-SG-22 / MS-SG-23 Rear unlocking button kit for a frame (Optional)
Rear unlocking button mounting
dimensions
Button (PA66)
Hinge + plate
[Stainless steel (SUS)]
2 or 4-M4 thread
Button pressed
(unlocked)
16
0.630
27.3 1.075 Button released
33 1.299
16 to 30
0.63 to 1.181
30 1.181
Safety door
switch with
key SG-B2
series
Pin [Stainless steel (SUS)]
Total thickness of mounting frame, panel, and
mounting plate: 23 to 43 mm 0.906 to 1.693 in
SG-E1
Key selector switch
Connection link
material:
Stainless steel
(SUS)
Example: When mounted on a □30 mm □1.181 in frame using the mounting plate
above MS-SG-21, select MS-SG-22 since the mounting part thickness (X)
is 40 (X = 10 + 30 = 40) 1.575 (X = 0.394 + 1.181 = 1.575).
For more information about selecting a back manual unlocking button kit
for a frame, see the following table:
Mounting part* thickness (X) (mm in)
Screw: Steel
SG-D1
Model No.
Rear unlocking button type
When installing an SG-B2-K2□D-L5 with
a rear unlocking button directly
MS-SG-22
33 < X ≤ 43 1.299 < X ≤ 1.693
MS-SG-23
23 < X ≤ 33 0.906 < X ≤ 1.299
* The mounting part is a frame or a panel that the product is mounted on.
Note: With the mounting hole dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways.
30
60.5 2.382
for n
ole tto
9 h g bu
0
7
n
0. ki
8 ø loc
ø1 ar un
re ote)
(N
25.5 1.004
60.5 2.382
25.5 1.004 33 1.299
31.5 1.240
Emergency stop switch
21.3 0.839
73 2.874
75
ø1.5
SG-C1
ø40
ø10.4 ø0.409
40 1.575
SG-C1
SERIES
Enable grip switch
Designation
Series
Applicable
standards
Standards for
use
Ambient
temperature
DC
AC
DC
AC
DC
AC
DC
B10d
Indicator (Note)
Weight
50 A (250 V)
250 V AC, 10 A Fuse (IEC60127-1)
60 N min. (Push monitor switch)
4.7 mm 0.185 in min. (Push monitor switch)
500 N min. (Grip switch)
Green LED
Rated Operating Voltage: DC 24 V ±10 %
Rated current: 15 mA
SG-C1-21: Approx. 140 g
SG-C1-21-E: Approx. 150 g
SG-C1-21-EG: Approx. 155 g
SG-C1-21-MM: Approx. 155 g
SG-C1-21-EMM: Approx. 165 g
SG-C1-21-EMK: Approx. 170 g
Note: As for the type with pilot light, Ue (contact ratings) of all switches is
only less than 30 V DC, and connect all switches to SELV (safety
extra low voltage) or PELV (protective extra low voltage) circuit.
SG-B2
SG-C1
SG-E1
Key selector switch
Mechanical
durability
Electrical
durability
Shock resistance
Free fall
Vibration
resistance
IP66 / IP67
Protection
IP65
Conditional shortcircuit current
Short-circuit
protective device
Direct opening force
Direct opening travel
Actuator Strength
(Entire button is pushed)
• Use proper size wires to meet voltage and current requirements.
• Do not apply an excessive shock to the SG-C1 series.
• When wiring, prevent dust, water, or oil from entering the grip switch.
• If used in wet locations, this device must be used with cable
suitable for wet locations.
• When multiple safety components are connected in series, the
EN ISO 13849-1 performance level will fall due to the
deterioration in fault detection functionality.
• The suitability of control systems in which this product has been
embedded must be verified in accordance with EN ISO 13849-2.
• SG-C1 series is a device used for enabling a machine (robot,
etc.) when teaching the machine in a hazardous area manually.
Configure the enabling system so that the machine can operate
when the switch is in position 2 and an additional “start” is pushed
to initiate the operation.
• In order to ensure safety of the control system, connect each pair
of the contacts of the 3 position enabling switch (terminal No.
NO1-C1 and NO2-C2) to a discrepancy detection circuit such as
a safety relay module.
(ISO13849-1)
• The base and the plastic part of rubber boot frame are made of
glass-reinforced ABS / PBT. The rubber boot is made of silicone
rubber. The screw is made of iron. When cleaning the SG-C1
series, use a detergent compatible with the materials
• As for momentary pushbutton switch and key selector switch of
additional control unit, do not connect NO and NC contacts of a
microswitch to different voltages or different power sources to
prevent a dead short-circuit.
• Do not operate key selector switch of additional control unit
without completely insertion of the key.
• The rubber boot may deteriorate depending on the operating
environment and conditions.
SG-B1
SG-A1
Emergency stop switch
Electric shock
protection class
Operating frequency
• In order to avoid electric shock or fire, turn the power
off before installation, removal, wire connection,
maintenance, or inspection of the safety switch.
• Do not disassemble or modify the grip switch.
• When using the SG-C1 series for safety-related
equipment in a control system, refer to the safety
standards and regulations in each country and
region depending on the application purpose of the
actual machines and installations to make sure of
correct operation. Also, perform risk assessment to
make sure of safety before starting operation.
• Do not tie the grip switch around the button with a
tape or string to keep the switch in position 2. Doing
so will prevent the grip switch from functioning as
designed and is extremely dangerous. Systems that
stop operation after the grip has been operated for
a certain period of time and require the operator to
grip it again are effective in preventing
circumvention of the device’s intended purpose.
• Please note that permanent installation of the grip
switch at the machine is inadmissible.
Enable grip switch
Rated
operational
voltage (Ue) /
Rated
operational
current (Ie)
(Note)
Grip switch
AC
Ambient humidity
Pollution degree
Altitude
Impulse withstand
voltage (Uimp)
Rated insulation
voltage (Ui)
Thermal current (Ith)
IEC 60947-5-1, EN 60947-5-1, JIS C 8201-5-1,
GS-ET-22, UL 508, CSA C22.2 No.14
ISO 12100 / EN ISO 12100, IEC 60204-1 / EN 60204-1,
ISO 11161 / EN ISO11161, ISO 10218-1 / EN ISO 10218-1,
ANSI/RIA/ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19,
ISO 13849-1 / EN ISO 13849-1
Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +60 °C -13 to +140 °F (No dew
condensation or icing allowed)
Storage: -40 to +80 °C -40 to +176 °F
45 to 85 % RH
3 (Inside 2)
2,000 m 6,561.68 ft max.
2.5 kV (Momentary pushbutton switch and key
selector switch: 1.5 kV)
250 V (Momentary pushbutton switch and key
selector switch: 125 V) / Models with indicator: 30 V
3 A (Emergency stop switch: 5 A)
Ie
Ue 30 V 125 V 250 V
Resistive load (AC-12) - 1 A 0.5 A
3 position
Inductive load (AC-15) - 0.7 A 0.5 A
enabling switch
(Terminal No.:
Resistive load (DC-12) 1 A 0.2 A NO1-C1, NO2-C2)
Inductive load (DC-13) 0.7 A 0.1 A Resistive load (AC-12) - 2.5 A 1.5 A
Inductive load (AC-15) - 1.5 A 0.75 A
Push monitor switch
(Terminal No. 31-32)
Resistive load (DC-12) 2.5 A 1.1 A 0.55 A
Inductive load (DC-13) 2.3 A 0.55 A 0.27 A
Resistive load (AC-12) - 5 A 3 A
Emergency stop
Inductive load (AC-15) - 3 A 1.5 A
switch
Resistive load (DC-12) 2 A 0.4 A 0.2 A
(Terminal No. 1-2, 1-2)
Inductive load (DC-13) 1 A 0.22 A 0.1 A
Momentary pushbutton switch
Resistive load (AC-12) - 0.5 A / Key selector switch
Inductive load (AC-15) - 0.3 A (Terminal No. C1 NO1
NC1,
Resistive load (DC-12) 1 A 0.2 A
C2 NO2,
Inductive load (DC-13) 0.7 A 0.1 A
NC2 )
Class II (IEC 61140), (double insulated)
(Models with indicator: Class III)
1,200 operations/hour
2,000,000
(ISO 13849-1 Annex C Table C.1)
Position 1⇒2⇒1: 1,000,000 operations min.
Position 1⇒2⇒3⇒1: 100,000 operations min.
100,000 operations min. (Rated operating load)
1,000,000 operations min. (AC / DC 24 V 100 mA)
Malfunction: 150 m/s2, Destruction: 1,000 m/s2
1.0 m 3.281 ft 1 time (Based on IEC60068-2-32)
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
Destruction: 16.7 Hz, half amplitude 1.5 mm 0.059 in
Without additional switch and pilot light
With additional switch and/or pilot light
• This catalog is a guide to select a suitable product.
Be sure to read the instruction manual attached to the product
prior to its use.
Safety door switch with key
Operating condition
Applicable
directives
Enable grip switch
SG-C1 series
Safety door switch
Safety door switch with solenoid interlock
Item
Precautions for proper use
Cable glands
• The product includes one cable gland. When purchasing
replacements, ensure that they conform to the following
dimensional range:
• Dimension diagram
Threaded part
(M16 × 1.2 mm 0.047 in)
15 mm
0.591 in max.
22 mm
0.866 in max.
Specifications
SG-D1
Cable gland
• Waterproofness: Use a cable gland that can maintain
performance of IP67 or higher.
• Recommended connector: Model SKINTOP-BS-M16 × 1.5-B
(manufactured by LAPP in Germany and imported by K.mecs
Co., Ltd.)
• Applicable cable diameter: Outer diameter of 4.5 to 10 mm 0.177
to 0.787 in
31
SG-C1 SERIES
Precautions for proper use
Dimensions (Unit: mm in)
Wire length inside the grip switch
SG-C1-□ Enable grip switch
SG-B1
SG-A1
Sheath
Indicator
Momentary pushbutton
switch /
Key selector switch
Emergency
stop switch
Safety door switch with key
Emergency
stop switch
83 3.268
Emergency stop
50 1.969
62 2.441
switch
Grip switch
16 0.630
L
+ 115
4.528
SG-C1-21
134 5.276
5 mm 0.197 in
Indicator
78 3.071
Momentary
pushbutton switch
Grip switch
(64 2.52)
Safety door switch
Safety door switch with solenoid interlock
Momentary
Emergency
Wire
pushbutton switch
Grip switch
stop switch
stripping
/ Key selector switch
length
NO1 C1 31 32 NO2 C2 C
NO NC
1
2
40 45 50 60 85 80
120
110
L (mm in)
1.575 1.772 1.969 2.362 3.346 3.150
4.724
4.331
(94 3.701)
Cable gland
(Accessory)
Applicable wire size in terminal
SG-B2
Emergency stop
switch
• If direct-mounted: 0.5 mm2 (AWG20) or less
Wire SG-C1 series according to IEC60204-1
Wiring Instruction
16 0.630
SG-C1-21-E / SG-C1-21-EG
Enable grip switch
A
1.1 to 1.3 N·m
SG-C1-21-EMK
Emergency stop
switch
Key selector
switch
Rubber boot
Cable
gland
SG-C1-21-EMM
B
C
A (M4 screw × 4)
Base
Key selector switch
B
2.7 to 3.3 N·m
C
2.7 to 3.3 N·m
The B and C values in the above table
reflect use of the recommended
connectors listed above.
When using a cable gland other than the
recommended model, check that part’s
tightening torque.
78 3.071
4 0.157
11 0.433
16 0.630
Emergency stop switch
SG-E1
For mounting rubber
boot frame on the
base (M4 screw × 4)
Cable gland to Grip
switch Screw
Cable gland to cable
gland
Screw Screw tightening
position torque
Note: Not included in SG-C1-21-E.
Momentary
pushbutton switch
Recommended screw tightening torque
Part being secured
Indicator (Note)
Emergency stop
switch
16 0.630
SG-C1
• Solder the terminal at 310 to 350 °C 590 to 662 °F within 3
seconds using a 60 W soldering iron.
Sn-Ag-Cu type is recommended when using lead free solder.
• When soldering, do not touch the SG-C1-□ with the soldering
iron. Also ensure that no tensile force is applied to the terminal.
Do not bend the terminal or apply excessive force to the terminal.
• Use non-corrosive rosin flux.
• Because the terminal spacing is narrow, use protective tubes or
heat shrinkable tubes to avoid burning of wire coating or short
circuit.
• When using a stranded wire, make sure that adjoining terminals
are not short-circuited with protruding core wires.
• Use copper wire 60 to 75 °C 140 to 167 °F only. (UL508)
• The wiring has to be installed according to GS-ET-22, 4.2.6.
5 0.197
Wiring
78 3.071
78 3.071
Base
Momentary
pushbutton switch
SG-C1-21-MM
SG-D1
16 0.630
75 2.953
Emergency stop
switch
78 3.071
32
Indicator (Note)
5 0.197
Momentary
pushbutton switch
Note: Not included in SG-C1-21-E.
SG-E1
Pushbutton type
SERIES
Emergency stop switch
Specifications
Designation Pushbutton type emergency stop switch
Series
SG-E1 series
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1,
UL 508 (UL listed Certification), CSA 22.2
No.14 (c-UL listed Certification)
-25 to +60 °C -13 to +140 °F (No dew
condensation or icing allowed)
Storage: -40 to +80 °C -40 to +176 °F
Ambient humidity
45 to 85 % RH
Pollution degree
3
Altitude
4 kV
Rated insulation
voltage (Ui)
600 V
ø22.3 +0.4
0 ø0
.87
8 0+0.016
10 A
Ue 24 V 48 V 50 V 110 V 220 V 440 V
Resistive
10 A
load (AC-12)
-
10 A 10 A 6 A 2 A
Inductive
load (AC-15) 10 A
(A600)
-
7A 5A 3A 1A
Resistive
8A 4A
load (DC-12)
-
2.2 A 1.1 A
-
Inductive
load (DC-13) 4 A 2 A
(P600)
-
1.1 A 0.6 A
-
Contact
resistance
50 mΩ max. (initial value)
Insulation
resistance
100 MΩ min. (500 V DC megger)
Class II (IEC 61140)
II (IEC60664-1)
Reset action
Turn reset
Protection
Front of the panel: IP65 (IEC 60529)
Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2
Vibration
resistance
B10d
Mechanical
durability
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
100,000
(ISO 13849-1 Annex C Table C.1)
500,000 operations min.
500,000 operations min. (900 operations/hour)
Material
Actuator: PA6, Contact block: PA66
Terminal screw (M3.5 philips & flathead )
Max. 2 mm2 (Single core ø1.6 ø0.063 max.)
2 wires max.
Tightening torque of
the terminal screws
1.0 to 1.3 N·m
Tightening torque
of the locking ring
2.0 N·m
Weight
Accessory
SG-E1-02-□: Approx. 60 g, SG-E1-12-□: Approx. 75 g
Lever lock: 1 pc
SG-B2
• The minimum mounting centers are applicable to switches with
one layer of contact blocks (two contact blocks).
When two layers of contact blocks are mounted, determine the
minimum mounting centers in consideration of convenience for
wiring.
Applicable wiring
(1) The applicable wire size is 2 mm2 maximum. (single wire ø1.6
mm ø0.063 in maximum) One or two wires can be connected.
• Applicable crimping terminal (Unit: mm in)
When using direction Ⓐ
SG-C1
ø3.6 ø0.142 min.
Ⓐ
Ⓐ
8 0.315 max.
4 0.157 max.
Ⓑ
Ⓑ
Ⓑ
Ⓑ
6 0.236 min.
When using direction Ⓑ
ø3.6 ø0.142 min.
6.6 0.260 max.
4 0.157 max.
Ⓐ
6 0.236 min.
SG-E1
Be sure to use an insulation tube or cover on the crimping part of
the crimping terminal to prevent electrical shocks.
• Single wire (Unit: mm in)
Key selector switch
Applicable wire
size
+0.008
Ⓐ
Electrical
durability
Connecting
method
+0.2
Emergency stop switch
Overvoltage
category
The 3.2 0 0.126 0 recess is for
preventing rotation and not necessary
when anti-rotation is not used.
When anti-rotation is not required
or when the panel cut-out does not
have anti-rotation recess, remove
the “Projection” using pliers.
ø1.6 ø0.063 max.
Electric shock
protection class
50 1.969
Note:
When using the safety lever lock,
determine the vertical spacing* in
consideration of convenience for
installing and removing the safety
lever lock. (Recommended vertical
spacing: 100 mm 3.937 in or more)
Enable grip switch
DC
AC
Ie
(mm in)
+0.008
*3.2+0.2
0 0.126 0
(45 min.)
Thermal current (Ith)
R0.8 R0.031 max.
SG-B1
SG-A1
Safety door switch with key
Impulse withstand
voltage (Uimp)
Rated
operational
voltage (Ue) /
Rated
operational
current (Ie)
Mounting hole layout / minimum mounting center
2,000 m 6,561.68 ft max.
+0.016
24.1+0.4
0 0.949 0
Ambient
temperature
50 1.969 (*)
Operating condition
Applicable
standards
• In order to avoid electric shock or fire, turn the power
off before installation, removal, wire connection,
maintenance, or inspection of the safety switch.
• Use wiring that is appropriate for the applied
voltage and energized current, and tighten terminal
screws (M3.5) to the recommended tightening
torque (1.0 to 1.3 N·m). Using the switch when the
screws are loose will cause it to become extremely
hot, posing the risk of fire.
Safety door switch
Safety door switch with solenoid interlock
Item
Precautions for proper use
8 0.315 max.
Note: W
hen connecting wires to contact blocks or transformers in the direction
Ⓑ, keep the insulation stripping length 6.6 mm 0.260 in at the maximum.
(2) Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m.
SG-D1
Using the lever lock
• Panasonic Industrial Devices SUNX strongly recommends using
the lever lock (yellow) to prevent heavy vibration or maintenance
personnel from unlocking the contact assembly.
33
SG-E1 SERIES
Dimensions (Unit: mm in)
5XEEHUJDVNHW
0RXQWLQJSDQHOWKLFNQHVVWRWR
/RFNLQJOHYHU1RWH /RFNLQJULQJ
/HYHUORFN1RWH
7HUPLQDOVFUHZ
0
/2
SG-B1
SG-A1
FRQWDFWEORFNV FRQWDFWEORFNV
FRQWDFWEORFNV
FRQWDFWEORFNV
&.
¡¡
'XPP\EORFN
Safety door switch
Safety door switch with solenoid interlock
SG-E1-□ Emergency stop switch
Safety door switch with key
Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever.
SG-E1-□-E SEMI emergency off (EMO) switch
5XEEHUJDVNHW
0RXQWLQJSDQHOWKLFNQHVVWRWR
/RFNLQJOHYHU1RWH /RFNLQJULQJ
/HYHUORFN1RWH
7HUPLQDOVFUHZ
0
/2
Enable grip switch
FRQWDFWEORFNV FRQWDFWEORFNV
FRQWDFWEORFNV
FRQWDFWEORFNV
SG-B2
&.
¡¡
'XPP\EORFN
Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever.
SG-EP□ Emergency stop nameplate (Optional)
SG-C1
62
2.3
0ø
ø6
Emergency stop switch
ø2
SG-ET1 Locking ring wrench (Optional)
2ø
110 4.331
66
1.0 0.039
Height of SEMI emergency off (EMO) switch and SEMI guard ring
MS-SG-GR1 SEMI guard ring (Optional)
SG-E1
As illustrated below, the height of the SEMI emergency off (EMO) switch
and SEMI guard ring should be 3 mm 0.118 in or less.
35 1.378
A (Note)
25 0.984
0.8
ø74 ø2.913
ø66 ø2.598
66
52 2.047
Key selector switch
2ø
ø
02
.1
ø1
0.8
1.5 0.059
ø2
28
3 mm 0.118 in max.
SG-D1
42 1.654
T = 2.0 0.079
Note: When anti-rotation is not required or when the panel cut-out does not
have an anti-rotation recess, remove part “A” of the SEMI guard ring
using pliers.
34
• Note
The EMO switch and the guard ring have been designed for
applications in semiconductor manufacturing equipment only. Do
not use EMO switch and/or the guard ring which are installed on
machine tools or food processing machines.
(Machinery Directive of the European Commission and IEC 602041 require that emergency stop switches be installed in a readily
accessible area and the usage of switch guards is not permitted.)
SG-D1
SERIES
Key selector switch
Specifications
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1,
UL 508 (UL listed Certification), CSA 22.2
No.14 (c-UL listed Certification)
-25 to +60 °C -13 to +140 °F (No dew
condensation or icing allowed)
Storage: -40 to +80 °C -40 to +176 °F
Ambient
temperature
Ambient humidity
45 to 85 % RH
Pollution degree
3
Altitude
Rated insulation
voltage (Ui)
600 V
ø22.3 +0.4
0 ø0
.87
8 0+0.016
10 A
Ue 24 V 48 V 50 V 110 V 220 V 440 V
Resistive
10 A
load (AC-12)
-
10 A 10 A 6 A 2 A
Inductive
load (AC-15) 10 A
(A600)
-
7A 5A 3A 1A
-
2.2 A 1.1 A
-
Inductive
load (DC-13) 4 A 2 A
(P600)
-
1.1 A 0.6 A
-
50 mΩ max. (initial value)
Insulation
resistance
100 MΩ min. (500 V DC megger)
Class II (IEC 61140)
II (IEC60664-1)
Mechanical
durability
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
100,000
(ISO 13849-1 Annex C Table C.1)
Material
Actuator: PA6, Contact block: PA66
Tightening torque of
the locking ring
Ⓐ
Ⓐ
8 0.315 max.
4 0.157 max.
Ⓑ
Ⓑ
Ⓑ
Ⓑ
6 0.236 min.
When using direction Ⓑ
ø3.6 ø0.142 min.
Terminal screw (M3.5 philips & flathead )
Max. 2 mm2 (Single core ø1.6 ø0.063 max.)
2 wires max.
1.0 to 1.3 N·m
2.0 N·m
Ⓐ
4 0.157 max.
Ⓐ
6 0.236 min.
Be sure to use an insulation tube or cover on the crimping part of
the crimping terminal to prevent electrical shocks.
• Single wire (Unit: mm in)
8 0.315 max.
Selector behavior
2 positions
Note: W
hen connecting wires to contact blocks or transformers in the direction
Ⓑ, keep the insulation stripping length 6.6 mm 0.260 in at the maximum.
Minimum direct opening
operating angle
90°
(2) Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m.
Minimum direct
opening torque
0.4 N·m
Maximum
operation angle
90°
Weight
Accessory
SG-E1
Key selector switch
Tightening torque of
the terminal screws
SG-C1
ø3.6 ø0.142 min.
6.6 0.260 max.
100,000 operations min. (1,200 operations/hour)
Applicable wire
size
(1) The applicable wire size is 2 mm2 maximum. (single wire ø1.6
mm ø0.063 in maximum) One or two wires can be connected.
• Applicable crimping terminal (Unit: mm in)
When using direction Ⓐ
100,000 operations min.
Electrical
durability
Connecting
method
Applicable wiring
ø1.6 ø0.063 max.
B10d
+0.008
• The minimum mounting centers are applicable to switches with
one layer of contact blocks (two contact blocks).
When two layers of contact blocks are mounted, determine the
minimum mounting centers in consideration of convenience for
wiring.
Front of the panel: IP65
Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2
Vibration
resistance
+0.2
Emergency stop switch
Protection
The 3.2 0 0.126 0 recess is for
preventing rotation and not
necessary when anti-rotation is
not used.
SG-B2
Resistive
8A 4A
load (DC-12)
Contact
resistance
Overvoltage
category
30 1.181
Note:
When using the safety lever lock,
determine the vertical spacing* in
consideration of convenience for
installing and removing the safety
lever lock. (Recommended vertical
spacing: 100 mm 3.937 in or more)
Enable grip switch
DC
AC
Ie
(mm in)
+0.008
*3.2+0.2
0 0.126 0
(45 min.)
Thermal current (Ith)
R0.8 R0.031 max.
SG-B1
SG-A1
Safety door switch with key
4 kV
Electric shock
protection class
Mounting hole layout / minimum mounting center
2,000 m 6,561.68 ft max.
Impulse withstand
voltage (Uimp)
Rated
operational
voltage (Ue) /
Rated
operational
current (Ie)
• In order to avoid electric shock or fire, turn the power
off before installation, removal, wire connection,
maintenance, or inspection of the safety switch.
• Use wiring that is appropriate for the applied
voltage and energized current, and tighten terminal
screws (M3.5) to the recommended tightening
torque (1.0 to 1.3 N·m). Using the switch when the
screws are loose will cause it to become extremely
hot, posing the risk of fire.
50 1.969 (*)
Operating condition
Applicable
standards
Key selector switch
SG-D1 series
+0.016
24.1+0.4
0 0.949 0
Designation
Series
Safety door switch
Safety door switch with solenoid interlock
Item
Precautions for proper use
SG-D1
Using the lever lock (accessory)
• Please attach the lever lock (yellow) after locking to prevent
personnel from forgetting to lock the lock lever.
SG-D1-2□11: Approx. 75 g, SG-D1-2□22: Approx. 95 g
Key: 2pcs., Lever lock: 1 pc.
35
SG-D1 SERIES
Dimensions (Unit: mm in)
SG-D1-□ Key selector switch
Mounting panel thickness: 0.8 to 6 0.031 to 0.236
Rubber gasket
M3.5 M0.138
Terminal screw
Contact block
Locking lever (Note)
Lever lock (Note)
LO
CK
2 contact blocks /
4 contact blocks
48.5 1.909 (2 contact blocks),
68.5 2.697 (4 contact blocks)
14.4 0.567
49.4 1.945 (2 contact blocks),
69.4 2.732 (4 contact blocks)
41.4 1.630
25 0.984
26.5 1.043
ø2
9.
4
Locking ring
ø1
.1
57
0.5 0.020
29.4 1.157
37.4 1.472
Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever.
SG-ET1 Locking ring wrench (Optional)
110 4.331
8
ø2
02
.1
ø1
Please contact ..........
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Global Sales Department
■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global
All Rights Reserved ©
No. CE-NSDLU-5 July, 2013
Specifications are subject to change without notice.
2013
Printed in Japan