SG-B1-SA-G1

SG-B1-SA-G1

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    开关 操作力6118gf 工作温度-25℃~+50℃

  • 数据手册
  • 价格&库存
SG-B1-SA-G1 数据手册
Safety Devices New Products Line Up Introducing a safety door switch with solenoid interlock that is among the world’s thinnest* Safety is assured during maintenance! 2013.07 panasonic.net/id/pidsx/global * Based on research conducted by our company as of March 2013. Introducing a range of new safety devices! Panasonic Industrial Devices SUNX offers comprehensive safety solutions through an extensive selection of safety devices and a robust support system. SAFETY SOLUTION Pushbutton type Emergency stop switch SG-E1 P.16~ SEMI emergency off (EMO) switch Enable grip switch SG-C1 P.14~ Safety door switch with key / Key selector switch SG-B2 / SG-D1 2 P.8~ / P.12~ Ultra-slim Safety door switch with solenoid interlock / Safety door switch SG-B1 / SG-A1 P.4~ Light curtain SF4B / SF2B * For product details, please refer to individual product catalogs or our website. Safety relay unit SF-AC * For product details, please refer to individual product catalogs or our website. 3 Safety door switch with solenoid interlock SG-B1 Ultra-slim SERIES Introducing a safety door switch with solenoid interlock that is among the world’s thinnest*! ased on research conducted by our company as of With 5 built-in contacts * BMarch 2013. 75 mm 2.953 in 15 mm 0.591 in Thin body 75 mm 2.953 in Safety door switch SG-A1 Ultra-slim SERIES Manual lock release can be operated from three directions. Space saving design with angled connection cable Angled connection cable Mi 30 nimu mm m r 1.1 adiu 81 s in Mi 30 nimu mm m r 1.1 adiu 81 s in SG-B1 series Space saving approx. 30 mm 1.181 in Connectable safety relay units All models come with cables pre-installed. The SG-B1 series and SG-A1 series ship with bundled cables already connected internally. Since there is no need to provide cables separately, and because they are already connected internally, the number of wiring man-hours is cut in half. SF-AC Supports up to control category 3 • 2NC inputs, safety output × 3 SG-B1 series / SG-A1 series  Standard door switch  Cable Integrated design Ships standard with cables. Energy-saving design  Order guide  Contact configuration / Operating patterns  Specifications  Precautions for proper use  Dimensions 4 P.7 P.18 P.19 P.20~ P.22~ The SG-B1 series features an energy-saving design requiring current consumption of just 110 mA at 24 V DC (100 mA for the solenoid and 10 mA for the indicator), even though it also incorporates a solenoid interlock. Low power consumption of 110 mA Can be installed on any door. Sliding doors SG-B1 Top mounting Top mounting series Actuator Rightopening Leftopening Front mounting Front mounting Rightopening Leftopening Hinged doors Top mounting Side mounting Leftopening Rightopening Rightopening Leftopening Bottom mounting Side mounting Up-opening SG-B1 series  Choose between two types of locks: • Spring lock • Magnet lock  Easy-to-see LED Wide viewing angle (approx. 120°) operation indicator Up-opening SG-A1 series  Features three built-in contacts yet is among world’s smallest designs.  Choose from two actuator entry slot orientations. The indicator is visible even from an angle. Mounting surface 5 Dimensions (Unit: mm in) SG-B1 series SG-A1 series (with solenoid interlock) 30 1.181 15 0.591 75 2.953 15 0.591 78 3.071 75 2.953 Mounting hole layout (Unit: mm in) SG-B1 series 50.8 2.000 30 1.181 30 1.181 50.8 2.000 50.8 2.000 50.8 2.000 SG-A1 series (with solenoid interlock) SG-B1 seriesseries SG-B1 28.5 1.122 28.5 1.122 1 0.039 20 1200.039 1 0.039 1 0.039 0.787 0.787 1 0.039 20 1200.039 1 0.039 1 0.039 0.787 0.787 Common actuators SG-B1 series (with solenoid interlock)  Horizontal / Vertical angle adjustable actuators SG-K13 SG-K14 SG-A1 series  Straight actuator SG-K11 6  Right-angle actuator SG-K12  Right-angle actuator (with plate) SG-K12A SG-B1 series SG-A1 series Features P.4~ Order guide P.7 Contact configuration / Operating patterns P.18 Specifications P.19 Precautions for proper use P.20~ Dimensions P.22~ Order guide Safety door switch with solenoid interlock Actuators are not included with door switches and must be purchased separately. Interlock force Type Main contacts Door monitor Lock monitor contacts contacts 1NC Spring lock type 1NO 500 N or more 1NC + 1NC 2NC 1NC Magnet lock type 1NO Cable length Model No. 1 m 3.281 ft SG-B1-SA-G1 5 m 16.404 ft SG-B1-SA-G5 1 m 3.281 ft SG-B1-SB-G1 5 m 16.404 ft SG-B1-SB-G5 1 m 3.281 ft SG-B1-MA-G1 5 m 16.404 ft SG-B1-MA-G5 1 m 3.281 ft SG-B1-MB-G1 5 m 16.404 ft SG-B1-MB-G5 Safety door switch Actuators are not included with door switches and must be purchased separately. Door monitor contacts 2NC 2NC + 1NO 3NC Cable length Model No. 1 m 3.281 ft SG-A1-02-1 5 m 16.404 ft SG-A1-02-5 1 m 3.281 ft SG-A1-12-1 5 m 16.404 ft SG-A1-12-5 1 m 3.281 ft SG-A1-03-1 5 m 16.404 ft SG-A1-03-5 Actuators Actuators are not included with door switches and must be purchased separately. Type • SG-K11 • SG-K12 • SG-K13 • SG-K14 • SG-K12A Model No. Straight actuator SG-K11 Right-angle actuator SG-K12 (Note 1) Right-angle actuator (with plate) SG-K12A Horizontal / vertical angle adjustable actuators (Note 2) SG-K13 SG-K14 Notes: 1) The right-angle SG-K12 actuator’s tensile strength is 100 N. Using the device with a load in excess of this value may cause it to fall off the door. If you anticipate that the tensile load during use will exceed 100 N, use the right-angle (with plate) SG-K12A. 2) Choose a model after verifying the required direction of operation based on the relationship between the door and safety switch. (Refer to p.21) 7 Safety door switch with key SG-B2 Solve issues related to machine safety and other safety measures with a safety door switch with key! SERIES No forgotten keys No locked-in workers No inadvertent machinery operation The safety door switch with key SG-B2 series locks and unlocks doors with keys. When an operator takes a key into a hazardous area, the safety door switch will not lock, and the equipment will stop, ensuring operator safety by preventing personnel from being closed inside the hazardous area and preventing equipment from starting to operate. Safety worker Safety door switch with key SG-B2 series ACTION 1 ACTION 1 ACTION 2 ACTION Door unlocked 2 Key brought into the hazardous area Hazards of the system and robot are isolated by the safety guard. The worker uses the key to unlock the door and disables the system from starting unexpectedly, then removes the key and brings it into the hazardous area. The system remains off until the worker walks out the door and locks the door with the key. This enables the worker carrying the key to work safely in the hazardous area. Connectable safety relay units Additionally, the key selector switch SG-D1 series can be used to switch equipment modes and unlock door locks with a single key. Partial mode change SF-AC Supports up to control category 3 • 2NC inputs, safety output × 3 ACTION 2 Key selector switch SG-D1 series Single key! ACTION 1 Safety door switch with key SG-B2 series ACTION 1  Order guide  Options  Contact configuration / Operating patterns  Specifications  Precautions for proper use  Dimensions 8 P.10 P.11 P.25 P.26 P.26~ P.28~ Door unlocked (safety output off) ACTION 2 Equipment mode change Hazards of the system and robot are isolated by the safety guard. When a worker needs to work inside the hazardous area for maintenance, the worker unlocks the safety guard using a key, disables the system from starting (1), removes the key and brings it into the hazardous area, and then changes the operation mode of each system to maintenance mode (2). While the worker is carrying out maintenance work in the hazardous area, the safety guard cannot be locked and the system cannot be turned on. This enables the worker to work safely in the hazardous area. Energy-saving design, no power supply required Since doors are locked and unlocked with a key, there is no need to supply power to the safety door switch. Head removal detection function Head removal detection function is employed in the SG-B2. With this innovative function, the monitor circuit (41-42) turns off when the head is removed from the switch, such as when removing the head to change the head direction. With the head installed on the switch, monitor circuits 41-42 and 51-52 operate in synchronization while the key locks / unlocks the actuator. When the head is removed, 41-42 turns off and 51-52 turns on. This disagreement is detected by the head removal detection function. Monitor circuit (41-42) with head removal detection function Actuator unlocked LOCK Head removed Actuator unlocked Actuator locked When the head removed UNLOCK Monitor circuit (NC) Pink 41 42 Pink / White OFF ON OFF Monitor circuit (NC) Brown 51 52 Brown / White OFF ON ON Note: Head removal detection function is not direct opening. High-security pin tumbler key types are used Disagreement Monitor circuit Actuator locked Available with rear unlocking button Models with a rear unlocking button allow the door to be unlocked from the inside in the event a worker is left in the hazardous area. All models come with cables pre-installed. Equipment combination examples related to machine safety Double-insulated design eliminates the need for grounding wires. Choose an actuator based on the door shape and application. Straight actuator SG-K21 / SG-K21A Pushbutton type emergency stop switch SG-E1 series Enable grip switch SG-C1 series Safety relay unit SF-AC Right-angle actuator SG-K22 / SG-K22A Slide actuator SG-K21S Horizontal / vertical angle adjustable actuators SG-K24 Key selector switch SG-D1 series Safety door switch with key SG-B2 series 9 Order guide Safety door switch with key Actuators are not included with door switches and must be purchased separately. Rear unlocking button 11 Monitor circuit : Monitor circuit : Blue Monitor circuit : Orange 2 3 Monitor circuit : 1 2 Blue / White 2 4 Orange / White UNLOCK LOCK Pink 41 4 2 Pink / White Brown 5 3 Monitor circuit : Blue Monitor circuit : Monitor circuit : Orange Monitor circuit : Monitor circuit : Blue Monitor circuit : Monitor circuit : Orange Monitor circuit : 11 1 2 Blue / White 21 2 2 Orange / White 11 1 2 Blue / White 21 2 2 Orange / White 5m 16.404 ft 5 4 Brown / White Without With Cable length Contact arrangement (Note) Pink 41 4 2 Pink / White Brown 51 5 2 Brown / White Pink 41 4 2 Pink / White Brown 51 5 2 Brown / White 5m 16.404 ft 5m 16.404 ft Note: The contact configuration shows the status when the actuator is inserted and the switch is locked. Key LOCK and UNLOCK positions are as shown on the right. Key removal position Model No. A (removable in all positions) B (removable in UNLOCK position) C (removable in LOCK position) A (removable in all positions) B (removable in UNLOCK position) C (removable in LOCK position) A (removable in all positions) B (removable in UNLOCK position) C (removable in LOCK position) SG-B2-K2AC-5 SG-B2-K2BC-5 SG-B2-K2CC-5 SG-B2-K2AD-5 SG-B2-K2BD-5 SG-B2-K2CD-5 SG-B2-K2AD-L5 SG-B2-K2BD-L5 SG-B2-K2CD-L5 Switches incorporate two detents so that they stop in each position. UNLOCK LOCK Actuators Actuators are not included with door switches and must be purchased separately. Type Description Model No. Straight actuator SG-K21 Straight actuator with rubber bushings SG-K21A Slide actuator The actuator tensile strength when using this product is 1,400 N. SG-K22 Right-angle actuator Right-angle actuator with rubber bushings Horizontal / vertical angle adjustable actuators SG-K21S SG-K22A The actuator tensile strength when using this product is 500 N. SG-K24 Note: When using a safety door switch with key on a hinged door, see page 27 for more information about the minimum door radius with which the switch can be used. • SG-K21 10 • SG-K21A • SG-K21S • SG-K22 • SG-K22A • SG-K24 Features P.8~ SG-B2 series Order guide P.10 Options P.11 Contact configuration / Operating patterns P.25 Specifications P.26 Precautions for proper use P.26~ Dimensions P.28~ Options Type Model No. Padlock hasp (Note 1) SG-PH2 Mounting plate (for mounting on an aluminum frame) MS-SG-21 Rear unlocking button kit for a frame (Note 2) MS-SG-22 MS-SG-23 Notes: 1) The shackle diameter for compliant padlocks ranges from ø5.5 to ø7.5 mm ø0.217 to ø0.295 in. Shackle diameter: ø5.5 to ø7.5 mm ø0.217 to ø0.295 in 2) For more information about selecting a back manual unlock button kit for a frame, see the following table: Mounting part* thickness (X) (mm in) Model No. Rear unlocking button type When installing an SG-B2-K2□D-L5 with a rear unlocking button directly MS-SG-22 33 < X ≤ 43 1.299 < X ≤ 1.693 MS-SG-23 23 < X ≤ 33 0.906 < X ≤ 1.299 * The mounting part is a frame or a panel that the product is mounted on. Padlock hasp Mounting plate (for mounting on an aluminum frame) Rear unlocking button kit for a frame • SG-PH2 • MS-SG-21 • MS-SG-22 • MS-SG-23 11 Key selector switch with direct open operation function Pin tumbler design for high security Key selector switch SG-D1 SERIES Mode change Key selector switch SG-D1 series ACTION 1 ACTION 1 Mode change Workers can be limited by using a key selector switch to switch modes when performing maintenance and program overwrites. Additionally, since the NC contact (b-contact) use direct open operation, the circuit will be reliably shut off by forcibly separating the NC contact, even if they have melted together. Use in combination with the safety door switch with key SG-B2 series to enable hostage control. Partial mode change ACTION 2 Key selector switch SG-D1 series Single key! ACTION 1 Safety door switch with key SG-B2 series ACTION 1  Order guide  Options  Specifications  Precautions for proper use  Dimensions 12 P.13 P.13 P.35 P.35 P.36 Door unlocked (safety output off) ACTION 2 Mode change Hazards of the system and robot are isolated by the safety guard. When a worker needs to work inside the hazardous area for maintenance, the worker unlocks the safety guard using a key, disables the system from starting (1), removes the key and brings it into the hazardous area, and then changes the operation mode of each system to maintenance mode (2). While the worker is carrying out maintenance work in the hazardous area, the safety guard cannot be locked and the system cannot be turned on. This enables the worker to work safely in the hazardous area. SG-D1 series Features P.12 Order guide P.13 Options P.13 Specifications P.35 Precautions for proper use P.35 Dimensions P.36 Order guide Key selector switch Position Contact configuration 1NO / 1NC (11) Contact block Mounting position (Note) ① 2NO / 2NC (22) Maintained 1 2 (Manual) 90 degree, 2-position 1NO / 1NC (11) 2NO / 2NC (22) 1NO / 1NC (11) 2NO / 2NC (22) Operator position Contact 1 NO ② NC ① NO ② NC ③ NO ④ NC ① NO ② NC ① NO ② NC ③ NO ④ NC ① NO ② NC ① NO ② NC ③ NO ④ NC 2   Key removal position Model No. SG-D1-2A11 A: All positions    ① ② SG-D1-2A22    SG-D1-2B11    B: Left position Not removable in right position ① SG-D1-2B22 ❷    SG-D1-2C11    C: Right position Not removable in left position SG-D1-2C22 ❶ ②  Note: Contact blocks are attached as shown below: ③④ ② ① Options Type Locking ring wrench Model No. Description SG-ET1 Used to tighten the locking ring when installing the unit onto a panel. Material: Brass Weight: approx. 150 g * Tighten the locking ring to a torque of 2.0 N·m. Locking ring wrench • SG-ET1 13 Compact, light weight grip switches designed to fit comfortably in the hand Enable grip switch SG-C1 SERIES (Push monitor switch) This product line includes models with control units suited to a variety of applications. The compact, light weight grip profile was designed based on human engineering considerations. The compact profile fits the hand perfectly, ensuring comfortable operation. Thanks to its light weight design (SG-C1-21: approx. 140 g) and compact size, it is easy to hold even for individuals with small hands, and it can also be used in confined work locations. Reduced impact during extended operation We reduced the impact during extended operation by lowering the holding load in position 2 (ON). Pleasant, clear button operation Tactile clicking feedback allows easy recognition of switch operation when shifting from position 1 (contact OFF) to position 2 (contact ON). Position 1 OFF Position 2 Squeeze gently. Release. ON  Order guide  Contact configuration / Operating patterns  Specifications  Precautions for proper use  Dimensions 14 P.15 P.15 P.31 P.31~ P.32 Position 3 Grip strongly. Release. OFF Features P.14 SG-C1 series Order guide P.15 Contact configuration / Operating patterns P.15 Specifications P.31 Precautions for proper use P.31~ Dimensions P.32 Order guide Enable grip switch Contact configuration 3 position enabling switch Additional control units Push monitor switch Emergency stop switch Control unit (A) Control unit (B) Indicator (green) (C) Rubber boot material / Color Wiring style SG-C1-21 Without With (2NC) 2 contacts With (1NC) Without With (2NC) SG-C1-21-E Without Without With Momentary pushbutton switch (2c) Momentary pushbutton switch (2c) Model No. Silicone rubber / (Yellow) (Note) Solder terminal SG-C1-21-EG SG-C1-21-MM SG-C1-21-EMM Without SG-C1-21-EMK Key selector switch (2c) Additional control unit layout Emergency stop switch Emergency stop switch Control unit (A) Indicator (C) Control unit (B) Note: Silicone rubber: Can be used in general factories. Remains flexible in cold temperatures. Suitable in applications with a wide operating temperature range. Contact configuration / Operating patterns Grip switch (during operation of center of the rubber boot) Terminal No. Solder terminal Position 2 Position 1 Position 3 3 position enabling switch: 2 contacts; pin No.: NO1-C1, NO2-C2 Push monitor switch: 0, 1 contacts: pin No.: 31-32 (SG-C1-21□) NO1-C1 Push (Position 1→2→3) 31-32 NO2-C2 Note: Push monitor switch (terminal No.31-32) will be positive opening circuit ( ) when the switch operates from position 2 to 3. Use contacts of terminal No. NO1-C1 and NO2-C2 for the output of enabling system. The above operating characteristics illustrate the performance when the center of the rubber boot is pressed. Pressing the edge activates one of the two 3 position enabling switches inside earlier than the other, and may cause a delay in the operation. NO1-C1 Release 31-32 (Position 2→1) NO2-C2 NO1-C1 Release 31-32 (Position 3→1) NO2-C2 : Contact ON (closed) : Contact OFF (opened) Key selector switch Operator position & contact operation (top view) Position (Left) Key removal position Left contact NO1 Maintained 1 2 NC1 (Right) Right contact NO2 NC2 Left contact NO1 NC1 Right contact NO2 NC2 Removable in all positions C1 C2 Indicator Pay attention to the polarity of the power supply as SG-C1-21-EG do not contain a diode for protection against reverse polarity. On solder terminal units, the terminal with a white paint marking is positive. C1 C2 Negative terminal White paint marking Terminal (plastic) Positive terminal 15 Push to lock, turn to reset Emergency stop switch SG-E1 Pushbutton type SERIES Switches feature simple operation: Push the pushbutton to lock the switch, and turn the switch in the direction shown by the arrow to reset it. Push to lock Turn to reset The product line includes a SEMI emergency off (EMO) switch. SEMI emergency off (EMO) switch Pushbutton type SEMI semiconductor industry safety standards SEMI standards comprise a series of guidelines put together by an industry group consisting of manufacturers of semiconductor manufacturing equipment, flat-panel displays, and associated materials. In the semiconductor industry, this guidelines have achieved the status of de facto international standards. Section 12.1 of the SEMI standards (S2 0706) states, “Equipment should incorporate an emergency off (EMO) circuit. When the EMO actuator (button) is triggered, the equipment should transition to a safe state in which no new hazard is posed to workers or equipment.” This provision likely stems from the need to address the possibility of secondary hazards that could occur when processing power and other inputs are stopped, reflecting the industry’s extensive use of materials such as solvents and chemicals, many of which contain hazardous or toxic substances. Consequently, SEMI standards require that normal emergency stop switches, which shut off the supply of energy, including power, be augmented with separate emergency off switches that shut off only the portion of the load that created the hazardous state while maintaining operation of other safety-related equipment (smoke detectors, gas / water leak detectors, pressure measurement equipment, etc.). When there is the possibility that the emergency off switch could be operated mistakenly, a guard must be installed and the switch must use direct opening operation. The button must be red with a yellow background, and the switch itself must include the letters “EMO.”  When installing a SEMI emergency off (EMO) switch on semiconductor manufacturing equipment, it should be installed at a height of 838 to 1,638 mm 32.992 to 64.488 in. (SEMI S8-0705)  According to SEMI standards, the EMO emergency stop switch must be installed within 3 m 9.843 ft of the work location. (SEMI S2-0706 12.5.2) 3 m 9.843 ft or less EMO  Order guide  Options  Specifications  Precautions for proper use  Dimensions 16 P.17 P.17 P.33 P.33 P.34 3 m 9.843 ft or less Worker EMO Max. installation height 1,638mm 64.488 in Min. installation height 838mm 32.992 in SG-E1 series Features P.16 Order guide P.17 Options P.17 Specifications P.33 Precautions for proper use P.33 Dimensions P.34 Order guide Emergency stop switch Type Contact configuration Button color Model No. SG-E1-02 2NC Pushlock Turn reset Red SG-E1-12 1NO / 2NC SEMI emergency off (EMO) switch Type Pushlock Turn reset Main contacts (NC contacts) Monitor contacts (NO contacts) 2NC — Button color / text color Model No. SG-E1-02-E Red / White 2NC SG-E1-12-E 1NO Options Type Model No. SG-EP1 SG-EP2 SG-EP3 Locking ring wrench SG-ET1 SEMI guard ring MS-SG-GR1 (Blank) Legend Emergency stop nameplate Emergency stop nameplate Description EMERGENCY STOP 非常停止 (Japanese) • SG-EP1 • SG-EP3 Background: Yellow Legend: Black Applicable panel thickness: 0.8 to 4.5 mm 0.031 to 0.177 in Material: Polyamide Used to tighten the locking ring when installing the unit onto a panel. Material: Brass, Weight: approx. 150 g * Tighten the locking ring to a torque of 2.0 N·m. Locking ring wrench • SG-ET1 For SEMI emergency off (EMO) switches. Specifically designed for use with semiconductor manufacturing equipment. Caution SEMI guard rings are designed specifically for use with semiconductor manufacturing equipment and should not be used as emergency stop switches for machine tools, food processing machinery, or other equipment. The European Machinery Directive, IEC 60204-1, JIS B9960-1, and other standards require that emergency stop switches be easy to approach and operate, and use of SEMI standard-compliant switch guards is not currently approved. ( • SG-EP2 SEMI guard ring • MS-SG-GR1 ) 17 SG-B1 SG-A1 Ultra-slim SERIES Ultra-slim SERIES Safety door switch with solenoid interlock Safety door switch Contact configuration / Operating patterns Safety door switch with solenoid interlock Safety door switch Safety door switch with solenoid interlock : Closed : Open Unlocking using Status 1 Status 2 Status 3 Status 4 manual unlocking key • Door closed • Door closed • Door open • Door open • Door closed • Machine ready to operate • Machine cannot be operated • Machine cannot be operated • Machine cannot be operated • Machine cannot be operated • Solenoid de-energized • Solenoid energized • Solenoid energized • Solenoid de-energized • Solenoid de-energized Safety switch status Door status SG-B1 SG-A1 Manual unlocking position • Closed (locked) • Closed (unlocked) • Open Safety door switch with key Door Spring lock type SG-B1-SA-□ Magnet lock type SG-B1-MA-□ (At actuator entry) (When solenoid off) Enable grip switch SG-C1 Model No. and contact configuration Door monitor Lock monitor SG-B2 (+)(When solenoid(–) (At actuator entry) off) SG-B1-SB-□ Magnet lock type SG-B1-MB-□ Main circuit: Monitor circuit: Main circuit: Monitor circuit: Monitor circuit: Monitor circuit: 11 21 11 31 21 31 • Closed (unlocked) Main circuit 11-42 Door monitor Lock monitor Main circuit: 11 Monitor circuit: 21 Main circuit: 11 Monitor circuit: 31 Monitor circuit: 21 Spring type31 Monitorlock circuit: • Open A2 (+) 12A2 41 22 51 12 41 32 22 51 32 A1 (–) 42 A1 52 42 52 Door monitor circuit (door closed) 21-22 Door monitor circuit (door closed) 31-32 Lock monitor circuit (locked) 51-52 Main circuit 11-42 Door monitor circuit (door closed) 21-22 12 22 12 32 22 32 41 53 41 53 Door monitor circuit (door closed) 31-32 42 54 42 54 Lock monitor circuit (unlocked) 53-54 Spring lock type • OFF (de-energized) • ON (energized) • ON (energized) • OFF (de-energized) • OFF (de-energized) Solenoid power A1-A2 (same for all models) • ON (energized) • OFF (de-energized) to Magnet lock type • ON (energized) • OFF (de-energized) • OFF (de-energized) ON (re-energized) (Note 2) Solenoid power A1-A2 (same for all models) (Note 1) (Note 2) Emergency stop switch Main circuit: Connected to the machine drive control circuit, sending the interlock signals of the protective door. Monitor circuit: Sends the monitoring signals of open / closed and lock / unlocked statuses of the protective door. Notes: 1) Do not attempt manual unlocking while the solenoid is energized. 2) Do not energize the solenoid for a long period of time while the door is open or while the door is unlocked manually. : Contact ON (closed) : Contact OFF (opened) • Operation characteristics (reference) 0 (Actuator mounting reference position) Approx. 1.1 0.043 (Lock) SG-B1-SA-□ Approx. 4.7 0.185 Approx. 27.4 1.079 Approx. 5.0 0.197 SG-B1-MA-□ (Travel: mm in) SG-E1 Main circuit (11-42) Door monitor circuit (21-22) Door monitor circuit (31-32) Lock monitor circuit (51-52) (Actuator completely inserted) SG-B1-SB-□ SG-B1-MB-□ Main circuit (11-42) Door monitor circuit (21-22) Door monitor circuit (31-32) Lock monitor circuit (53-54) 0 (Actuator mounting reference position) Approx. 1.1 0.043 (Lock) Approx. 4.7 0.185 Approx. 5.0 0.197 Approx. 27.4 1.079 (Travel: mm in) (Actuator completely inserted) (Actuator pulled out) (Actuator pulled out) Key selector switch • The operation characteristics show the contact status when the actuator enters an entry slot of an safety switch. • The operation characteristics shown in the chart above are of the SG-K11 / SG-K12 / SG-K13 and SG-K14 actuators. For the SG-K12A actuator, subtract 0.6 mm 0.024 in. Safety door switch Model No. Contact configuration SG-A1-02-□ 2NC 11 31 12 32 12 22 34 11-12 21-22 33-34 12 22 32 11-12 21-22 31-32 SG-D1 18 Operation characteristics 0.8 0.031 (Actuator mounting reference position) Approx. Approx. Approx. 28.2 1.110 (Travel: mm in) 0 SG-A1-12-□ 2NC + 1NO 11 21 33 SG-A1-03-□ 3NC 11 21 31 5.5 0.217 5.8 0.228 11-12 31-32 (Actuator completely inserted) : Contact ON (closed) : Contact OFF (opened) (Actuator pulled out) SG-B1SERIES / SG-A1SERIES Specifications SG-B1 SG-A1 SG-B2 SG-C1 Emergency stop switch Applicable EN 1088, IEC 60947-5-1, EN 60947-5-1, standards GS-ET-15, UL 508, CSA C22.2 No.14 Standards for use IEC 60204-1, EN 60204-1 Applicable Machinery directive (2006/42/EC) directives Low voltage directive (2006/95/EC) Ambient -25 to +70 °C -13 to +158 °F (No dew condensation or icing allowed) temperature Storage: -40 to +80 °C -40 to +176 °F Ambient humidity 45 to 85 % RH Pollution degree 3 (Inside 2) Altitude 2,000 m 6,561.68 ft max. Impulse withstand 4 kV voltage (Uimp) Rated insulation 300 V voltage (Ui) Thermal current 2.5 A (Ith) Ie Ue 30 V 125 V 250 V Rated operational Resistive load (AC-12) 2.5 A 1.5 A AC voltage (Ue) / Inductive load (AC-15) 1.5 A 0.75 A Rated operational Resistive load (DC-12) 2.5 A 1.1 A 0.55 A current (Ie) DC Inductive load (DC-13) 2.3 A 0.55 A 0.27 A Electric shock Class II (IEC 61140), (double insulated) protection class Protection IP 67 (IEC 60529) Malfunction: 300 m/s2 Shock resistance Destruction: 1,000 m/s2 Vibration Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in resistance Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in Operating 1,200 operations/hour frequency Actuator 0.05 to 1.0 m/sec. operating speed 2,000,000 B10d (ISO 13849-1 Annex C Table C.1) Mechanical 1,000,000 operations min. (GS-ET-15) durability 100,000 operations min. (AC-12, 250 V 1.5 A, Electrical DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) durability (1,200 operations/hour) Direct opening travel 8 mm 0.315 in min. Direct opening force 60 N min. Contact 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) resistance Short-circuit Use 250 V / 10 A fast acting type fuse protective device Conditional 50 A (250 V) short-circuit current Material Enclosure: PA66 Cable UL style 2464, No.20 AWG 6-core SG-A1-□-1: Approx. 120 g, SG-A1-□-5: Approx. 420 g Weight SG-E1 Key selector switch Solenoid / Indicator DC Safety door switch SG-A1 series Enable grip switch AC DC AC Operating condition Designation Series Safety door switch with key Applicable EN 1088, IEC 60947-5-1, EN 60947-5-1, standards GS-ET-19, UL 508, CSA C22.2 No.14 Standards for use IEC 60204-1, EN 60204-1 Applicable Machinery directive (2006/42/EC) directives Low voltage directive (2006/95/EC) Ambient -25 to +50 °C -13 to +122 °F (No dew condensation or icing allowed) temperature Storage: -40 to +80 °C -40 to +176 °F Ambient humidity 45 to 85 % RH Pollution degree 3 (Inside 2) Altitude 2,000 m 6,561.68 ft max. 300 V (Door monitor circuit) Rated insulation 150 V (Main, Lock monitor circuit) voltage (Ui) 30 V (Between ground and LED, solenoid circuit) Impulse 2.5 kV (Door monitor circuit) withstand voltage 1.5 kV (Main, Lock monitor circuit) (Uimp) 0.5 kV (Between ground and LED, solenoid circuit) Ambient temperature: Ambient temperature Thermal current -25 to +35 °C -13 to +95 °F 35 to +50 °C 95 to +122 °F (Ith) 2.5 A (up to 2 circuits) 1.0 A (1 circuit) 1.0 A (3 or more circuits) 0.5 A (2 or more circuits) Ue 30 V 125 V 250 V Ie Resistive load (AC-12) 2A Main Rated 1A circuit, look Inductive load (AC-15) operational monitor Resistive load (DC-12) 2 A 0.4 A voltage (Ue) / circuit Inductive load (DC-13) 1 A 0.22 A Rated Resistive load (AC-12) 2.5 A 1.5 A operational Door Inductive load (AC-15) 1.5 A 0.75 A current (Ie) monitor Resistive load (DC-12) 2.5 A 1.1 A 0.55 A circuit Inductive load (DC-13) 2.3 A 0.55 A 0.27 A Electric shock protection class Class II (IEC 61140) (Note 1), (double insulated) Operating frequency 900 operations/hour Actuator operating speed 0.05 to 1.0 m/sec. 2,000,000 B10d (ISO 13849-1 Annex C Table C.1) Mechanical durability 1,000,000 operations min. (GS-ET-19) 100,000 operations min. 900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A Electrical 1,000,000 operations min. durability 900 operations/hour, 24 V AC/DC 0.1 A resistive load Interlock force 500 N min. (GS-ET-19) (Note 2) Direct opening travel 8 mm 0.315 in min. Direct opening force 60 N min. 300 mΩ max. (initial value, 1 m 3.281 ft cable) Contact 700 mΩ max. (initial value, 5 m 16.404 ft cable) resistance Protection IP 67 (IEC 60529) Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2 Vibration Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in resistance Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in Short-circuit protective device Use 250 V / 10 A fast acting type fuse Material Enclosure: PA66 Cable UL style 2464, No.22 AWG 12-core Rated operating voltage DC 24 V 100% duty cycle Rated current 110 mA (solenoid 100 mA, LED 10 mA : initial value) Turn on voltage Rated voltage × 85 % max. (at 20 °C 68 °F) Turn off voltage Rated voltage × 10 % min. (at 20 °C 68 °F) Indicator Green LED SG-B1-□-G1: Approx. 220 g, SG-B1-□-G5: Approx. 600 g Weight Item Operating condition Designation Safety door switch with solenoid interlock Series SG-B1 series Safety door switch Safety door switch with solenoid interlock Item Notes: 1) Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. 2) The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. SG-D1 19 SG-B1SERIES / SG-A1SERIES Precautions for proper use Safety door switch Safety door switch with solenoid interlock • This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use. SG-B1 SG-A1 Safety door switch with key SG-B2 Enable grip switch • In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. • If relays are used in the circuit between the safety switch and the load, consider the danger and use safety relays, since welding or sticking contacts of standard relays may invalidate the functions of the safety switch. • Do not place a PLC in the circuit between the safety switch and the load. Safety and security can be endangered in the event of a malfunction of the PLC. • Do not disassemble or modify the safety switch, otherwise a breakdown or an accident may occur. • Do not install the actuator in a location where the human body may come in contact. Otherwise injury may occur. • Magnet lock type is locked when energized, and unlocked when de-energized. When energization is interrupted due to wire disconnection or other failures, the safety switch may be unlocked causing possible danger to the operators. Magnet lock type must not be used in applications where locking is strictly required for safety. Perform a risk assessment and determine whether solenoid lock type is appropriate. Both series SG-C1 Emergency stop switch SG-E1 Key selector switch • Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. • Do not apply external force on the actuator while unlocking, otherwise the actuator may not be unlocked. • Do not apply excessive shock to the safety switch when opening or closing the door. A shock to the safety switch exceeding 1,000 m/s2 may cause damage to the safety switch. • If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the safety switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the safety switch may affect the mechanism of the safety switch and cause a malfunction. • Do not store the safety switches in a dusty, humid, or organic-gas atmosphere, or in an area subjected to direct sunlight. • Use proprietary actuators only. When other actuators are used, the safety switch may be damaged. SG-B1 series SG-D1 20 • The locking strength is rated at 500 N. Do not apply a load higher than the rated value. When a higher load is expected, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. • Regardless of door types, do not use the safety switch as a door lock. Install a separate lock using a latch or other measures. • While the solenoid is energized, the switch temperature rises approximately 35 °C 95 °F above the ambient temperature (to approximately 85 °C 185 °F while the ambient temperature is 50 °C 122 °F). Do not touch to prevent burns. If cables come into contact with the switch, use heat-resistant cables. • Bouncing will occur on the lock monitor contact during locking and unlocking (reference value: 20 ms). • Although the SG-K11 / SG-K12 / SG-K12A actuators alleviate shock when the actuator enters a slot in the safety switch, make sure that excessive shock is not applied. If the rubber bushings become deformed or cracked, replace with new ones. SG-A1 series • Cover the unused actuator entry slot using the slot plug supplied with the safety switch. Minimum radius of hinged door • When using the safety switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (SG-K13 / SG-K14). Note: The values indicated in the figures below assume that there is no 6*.6*.$ mechanical interference between the actuator and the safety switch when the door is opened or closed. Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. 0 0  LQLP P XP  LQLP  XP P UDG 'RRUKLQJH When using the right-angle actuator / SG-K12A) P (SG-K12  LXV P UDG   LQ  LXV 'RRUKLQJH  LQ SG-B1 series 6*.6*.$ 0 L  QLP  XP P P UD G   LXV  LQ 0 L  QLP X  P PU P  DGLX 'RRUKLQJH   V LQ 'RRUKLQJH 6*.6*.$ 0  LQLP P XP P UDG  LXV  LQ 'RRUKLQJH 0  LQLP  XP P P UDG   LXV  LQ 'RRUKLQJH SG-A1 series 6*.6*.$ SG-K12 0 L  QLP X  SG-K12 P PU M P DG ini  LX 23 mu  V 0 m m raLQ m d 9 iu M ini .05 s 23 mu 5 i n 0 m m ra m d 9. ius 05 SG-K12 5 in 0 L  QLP X  P PU MP D 'RRUKLQJH 2 inim GLXV 30 um  m m radLQ 9. ius Door hinge Mi 0 55 23 nimu in 0 m m ra m 9. dius Door hinge 05 5 in SG-K12 Min 16 imum 0 m ra m dius 6.2 Min 99 in i 16 mum 0 m ra m dius 6.2 99 in M rad inim 16 ius um 0m m M 6.2 rad inimu 99 in 16 ius m 0m m 6.2 99 in 'RRUKLQJH Door hinge Door hinge Door hinge Door hinge Door hinge Door hinge SG-B1SERIES / SG-A1SERIES Precautions for proper use 50 mm 1.969 in Door hinge Minim adjustment 50 mm 9 in Door hinge the1.96actuator • When the door hinge is on the extension line of Label SG-K13 mounting surface: 70 mm 2.756 in SG-K13 • When the door hinge is on the extension SG-K14line of the safety switch SG-K14 surface: 50 mm 1.969 in Minimum radius SG-B1 series 50 mm 1.969 in • Mount the safety switch on a fixed piece of machinery or guard and the actuator on a hinged door. Avoid mounting both the safety switch and actuator on a hinged door. Doing so may cause equipment failure. For more information about how to mount the devices, see the following diagram: Minimum radius 50 mm 1.969 in Door hinge Door hinge Horizontal adjustment s adiu mr imu mm n 0 7 56 i 2.7 Door hinge Min s adiu mr imu mm n 70 56 i 2.7 M mm inimum ra 2.7 dius 56 in SG-K13 ius Minimum rad Vertical adjustment 50 mm 1.969 in SG-K13 Door hinge Label Minimum radius 50 mm 1.969 in Minimum radius 50 mm 1.969 in Door hinge Door hinge Horizontal ius rad SG-A1 series adjustment um 2.7 is on the extension line of the actuator 2mounting SG-K13 s SG-K13 SG-K14 SG-K13 SG-K14 70 .75 M2 mm inimum ra 2.7 dius 56 in Label Door hinge Min ra imu mm dius m Door hinge 2M.i7 n ra 5im6uin 70 mm dius m Door hinge 2.7 56 in 70 Label s radiu Door hinge um im adjustment Min 0 mm n SG-K14 7 5a6diui s Door hinge Vertical .7 r 2m imu adjustment Min 0 mm n Label 7 56 i SG-K13 2.7 Minim 70 u m m Door hinge rad Label m2 SG-K13 .75 ius SG-K14 6 in SG-K13 Vertical SG-K14 Min ra imu mm dius m Door hinge 2M.7 in5 ra im6uin 70 mm dius m Door hinge 2.7 56 in SG-K13 SG-K14 Label Minimum Door hinge radius 50 mm Min 1.9imu 69min Door hinge radius 50 mm 1.969 in SG-K13 SG-K14 SG-K14 Minimum radius Door hinge 50 mm 1.969 in Minimum radius Door Label hinge 50 mm 1.969 in Label Minimum Door hinge radius 50 mm 1.9 69m in Minimu Door hinge radius 50 mm 1.969 in 0WDSSHGKROH Cables • Do not fasten or loosen the gland at the bottom of the safety switch. • When bending the cable during wiring, make sure that the cable radius is kept at 30 mm 1.181 in minimum. • When wiring, make sure that water or oil does not enter the cable. • The solenoid has polarity. Make sure of the correct polarity when wiring. SG-E1 SG-B1 series Actuator angle adjustment (vertical / horizontal) • Using the angle adjustment screw (M3 hexagon-socket-head screw), the actuator angle can be adjusted. (refer to the dimensions on page 24) Adjustable angle: 0 to 20° • The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the safety switch. • After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not move. SG-C1 Key selector switch SG-K14 SG-K13 1.969 in adjustment Vertical adjustment SG-K13 SG-B2 +LQJHGGRRU 70 Horizontal Vertical adjustment Minimum radius Door hinge 50 mm Horizontal 1.969 in Label adjustment Minimum radius Door hinge 50 mm Safety switch: 1.0 to 1.5 N·m (Three M4 screws)* Actuator: 1.0 to 1.5 N·m (Two M4 screws)* *The above recommended tightening torques of the mounting screws are the values confirmed with hexagon-socket-head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not become loose after mounting. • Mounting bolts must be provided by the users. • To avoid unauthorized or unintended removal of the safety switch and the actuator, it is recommended that the safety switch and actuator are installed in a secure manner, for example using special screws or welding the screws. • When installing the SG-K12A actuator, use the mounting plate (supplied with the actuator) on the hinged door, and mount tightly 0VFUHZV using two M4 screws. The mounting plate has orientation. 0RXQWLQJSODWH Do not lose the mounting plate. $FFHVVRU\ Adequate performance cannot be obtained without the plate as 5XEEHUEXVKLQJ the actuator may fall off the door. Emergency stop switch radiu Door hinge Horizontal imum adjustment Min 0 mm ins 7 5ra6diu Door hinge SG-K14 7 Horizontal im2u.m Label adjustment Min 0 mm in 7 6 Recommended tightening torque for mounting screws Enable grip switch SG-K14 SG-K14 (Application on hinged doors) Door hinge Horizontal Minimum radius Door hinge 50 mm 1.969 in adjustment Door stop (Application on sliding doors) Note: W  hen mounting the actuator, make sure that the actuator enters the slot in the correct direction, as shown on the right figure. M mm inimum rad 2.7 ius 56 in 70 Door hinge SG-B1 SG-A1 Latch Label SG-K14 70 SG-B1 series Safety switch Door hinge Min SG-K13 SG-K14 SG-K11 Actuator Safety door switch with key SG-K13 Vertical adjustment SG-K12A Actuator Door &RQGXLW GLXV 0LQLPXPUD LQ PP  0LQLP X P UDGLXV P P LQ  Minimum adjustment Mounting Safety door switch Safety door switch with solenoid interlock When using the (SG-K13 / SG-K14) angle adjustable (vertical / horizontal) actuatorVertical um radius Horizontal radius &RQGXLW SG-D1 SG-A1 series Conduit us di in ra 75 m 5 . u im m 1 in M 0m 4 (Unit: mm in) 21 SG-B1SERIES / SG-A1SERIES Dimensions (Unit: mm in) +ROHIRUPDQXDOXQORFNLQJ ¡¡ UHIHUHQFH              WR WR 0DQXDOXQORFNLQJNH\     5    &  &    +ROHIRUPDQXDOXQORFNLQJ ¡¡ UHIHUHQFH KROHVIRU0VFUHZ ¡¡RU 0WDSSHGKROH      SG-B2    ¡  5 Safety door switch with key Ƒ   KROHVIRU0VFUHZ ¡¡RU0WDSSHGKROH  ¡ SG-B1 SG-A1         Mounting hole layout     Safety door switch Safety door switch with solenoid interlock SG-B1□ Safety door switch with solenoid interlock Enable grip switch   WR WR Note 1: Drill mounting holes so that they are properly aligned for the orientation in which the safety switch will be used. SG-E1 Actuator stop (Note 2) (Accessory) (25 0.984) 22.6 ±1 0.089 ±0.039 48.8 1.921 (14 0.551) When using the angle adjustable actuator (horizontal / vertical) (SG-K13 / SG-K14) 0.8 0.031 0.089 ±0.039 50.8 2.000 0.8 0.031 22.6 ±1 0.8 0.031 (5 0.197) When using the right-angle actuator (SG-K12 / SG-K12A) (14 0.551) Emergency stop switch (12.6 ±1 0.496 ±0.039) (6.2 0.244) When using straight actuator (SG-K11) (42 1.654)(Note 3) SG-C1 Actuator stop (Note 2) (Accessory) Actuator stop (Note 2) (Accessory) Key selector switch Notes: 2) The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. 3) 41.4 1.63 when using SG-K12 *The tensile strength of the SG-K12 actuator is 100N. If an excessive tensile force is applied, the actuator may fall off the door. When a tensile force exceeding 100N is expected, use the SG-K12A actuator with a plate. Actuator mounting reference position As shown in the figure on the right, the mounting reference position of the actuator when inserted in the safety switch is: The actuator stop on the actuator lightly touches the safety switch. *The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. 6DIHW\VZLWFK $FWXDWRUVWRS $FFHVVRU\ 6*. $FWXDWRU 22 'RRUVWRS  SG-D1 'RRUVWRS SG-B1SERIES / SG-A1SERIES Dimensions (Unit: mm in) SG-A1□ Safety door switch    5   5      “  “      “  “ SG-B2  “  “   “  “      “ “ $FWXDWRUVWRS 1RWH  $FFHVVRU\   Enable grip switch          “ “   When using the angle adjustable actuator (horizontal / vertical) (SG-K13 / SG-K14) When using the right-angle actuator (SG-K12)  When using straight actuator (SG-K11)   ¡ ¡  SG-B1 SG-A1 Safety door switch with key Note 1: Plug the unused actuator entry slot using the plug supplied with the switch. 7KHVDIHW\VZLWFKFDQEH PRXQWHGLQWZRGLUHFWLRQV    KROHVIRU0VFUHZ  6ORWSOXJ 1RWH  $FFHVVRU\ WRWR  ¡¡RU0WDSSHG          Safety door switch Safety door switch with solenoid interlock Mounting hole layout $FWXDWRUVWRS 1RWH  $FFHVVRU\ $FWXDWRUVWRS 1RWH  $FFHVVRU\ Note 2: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. SG-C1 :KHQPRXQWHG   5XEEHUEXVKLQJ  ¡  ¡    :KHQPRXQWHG    ¡¡  5XEEHUEXVKLQJ SG-E1 Key selector switch $FWXDWRUVWRS 1RWH  $FFHVVRU\ ¡¡    * The tensile strength of the SG-K12 actuator is 100N. If an excessive tensile force is applied, the actuator may fall off the door. When a tensile force exceeding 100N is expected, use the SG-K12A actuator with a plate. :KHQPRXQWHG          ¡  :KHQPRXQWHG       ¡   Right-angle actuator (SG-K12)  Straight actuator (SG-K11) Emergency stop switch SG-K11 / SG-K12 Actuator $FWXDWRUVWRS 1RWH  $FFHVVRU\ Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. Actuator mounting hole layout (Straight actuator, right-angle actuator) SG-D1  KROHVIRU0VFUHZ ¡¡RU0WDSSHG 23 SG-B1SERIES / SG-A1SERIES Dimensions (Unit: mm in) Safety door switch Safety door switch with solenoid interlock SG-K13 / SG-K14 Actuator Horizontal / vertical angle adjustable actuators (SG-K14) Horizontal / vertical angle adjustable actuators (SG-K13) * The SG-K14 differs from the SG-K13 in that the direction in which the metal parts on the tip of the actuator are embedded is reversed by 180°. 0.8 0.031 Orienting insert 3.5 0.138 1.2 0.047 (Horizontal adjustment) (Horizontal adjustment) Angle adjustment (M3 hexagon-socket-head screw) The orientation of actuator adjustment (horizontal / vertical) can be changed using the orienting insert (white plastic) installed on the back of the actuator. Do not lose the mounting plate. Orienting insert Safety door switch with key 20° 20° SG-B1 SG-A1 Changes in the orientation of adjustment for angle adjustable (horizontal / vertical) actuators Angle adjustment (M3 hexagon-socket-head screw) 13 0.512 28.2 1.110 20° 34 1.339 20° Actuator stop (Note) (Accessory) SG-B2 Angle adjustment (M3 hexagon-socket-head screw) Actuator stop (Note) (Accessory) 16.8 0.661 Orienting insert (Vertical adjustment) 2 0.079 25 0.984 7.5 0.295 5.5 0.217 Vertical adjustment Horizontal adjustment R2 (M .1 R Angle adjustment 4 h 0.0 2.5 0.098 (M3 hexagon-socket-head screw) ole 83 s) 15 0.591 Enable grip switch * The base is made of glass-reinforced PA66 (66 nylon). Angle adjustment screws are stainless steel (SUS). When using adhesive on screws, take material compatibility into consideration. Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. Actuator mounting hole layout (horizontal / vertical angle adjustable actuators) 25 0.984 SG-C1 2-holes for M4 screw (ø4.3 ø0.169 or M4 tapped) Emergency stop switch 24 0.945 15 9 0.591 0.354 ø10 ø0.394 3 0.118 • Manual unlocking key (Accessory: plastic) SG-E1 18 0.709 (24.5 0.965) Key selector switch SG-D1 24 6.5 0.256 Vertical adjustment SG-B2 SERIES Safety door switch with key Contact configuration / Operating patterns : Closed Status 2 • Door closed • Machine ready to operate Safety switch status Status 3 • Door closed • Machine cannot be operated Rear manual unlock • Door open • Machine cannot be operated Safety door switch Safety door switch with solenoid interlock Status 1 : Open • Door closed • Machine cannot be operated 3UHVV Door status ‡3UHVVUHDUXQORFNLQJ EXWWRQ 1RWH SG-B1 SG-A1 Door SG-B2-K2□C-5 11 Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor Monitor circuit circuit :: Monitor circuit circuit :: Monitor Monitor circuit :  /2&.  81/2&.    /2&.  81/2&.    /2&.  81/2&.    /2&.  81/2&.                  • Closed (locked) 12 11 23 12 24 12 13 12 24 23 24 Monitor circuit : LOCK UNLOCK Monitor circuit LOCK4 1 UNLOCK 42 LOCK45 31 UNLOCK 54 42 54 31 54 42 53 54 • Closed (unlocked) • Open • Closed (unlocked) (door closed) 11-12 Monitor circuit (door open) 23-24 Monitor circuit (locked) 41-42 SG-B2 Monitor circuit (unlocked) 53-54 SG-B2-K2□D-5 Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor Monitor circuit circuit :: Monitor circuit circuit :: Monitor Monitor circuit : Enable grip switch Monitor circuit (door closed) 11-12 11 12 21 11 21 22 21 1 21 2 21 22 Monitor circuit : SG-B2-K2□D-L5 41 42 54 11 54 22 54 1 54 2 51 52 Monitor circuit (door closed) 21-22 Monitor circuit (locked) 41-42 Monitor circuit (locked) 51-52 SG-C1 Monitor circuit (door closed) 11-12 Emergency stop switch Model No. and contact configuration  Safety door switch with key Circuit diagram (Example: SG-B2-K2□D-L5) Monitor circuit (door closed) 21-22 Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor circuit : Monitor Monitor circuit circuit :: 11 12 21 11 21 22 21 1 21 2 Monitor circuit circuit :: Monitor 41 42 45 11 45 22 54 1 54 2 Monitor circuit (locked) 41-42 Monitor circuit (locked) 51-52 : Contact ON (closed) : Contact OFF (opened) • Operation characteristics (reference) 0 (Actuator mounting reference position) Approx. 3.3 0.130 (Lock) SG-B2-K2□C-5 Approx. 5.3 0.209 Approx. 6.9 0.272 Monitor circuit (11-12) Monitor circuit (23-24) Monitor circuit (41-42) Monitor circuit (53-54) (Actuator completely inserted) Approx. 26.4 1.039 (Travel: mm in) (Actuator pulled out) SG-B2-K2□D-5 SG-B2-K2□D-L5 Monitor circuit (11-12) Monitor circuit (21-22) Monitor circuit (41-42) Monitor circuit (51-52) SG-E1 Key selector switch 2 1operator 2 2 is confined in a hazardous area, the actuator can be unlocked manually by pressing the rear unlocking button, which should be MonitorWhen circuit : the Notes: 1) 51 52 easily by the operator. Monitoraccessed circuit : 2) The above contact configuration shows the status when the actuator is inserted and the switch is locked. 3) Monitor circuit: Sends monitoring signals of protective door open / closed status or protective door lock / unlock status. 0 (Actuator mounting reference position) Approx. 3.3 0.130 (Lock) Approx. 5.3 0.209 Approx. 6.9 0.272 Approx. 26.4 1.039 (Travel: mm in) (Actuator completely inserted) (Actuator pulled out) SG-D1 • The characteristics show the contact status when the actuator enters an entry slot of an safety switch. • The characteristics shown in the chart above are of the SG-K21 actuator. For the others actuator, add 1.3 mm 0.051 in. When connecting the SG-B2 series to a safety circuit, connect the door monitor circuits (11-12) (41-42, 51-52) in series. (GS-ET-19) and the lock monitor circuits 25 SG-B2 SERIES Specifications SG-B1 SG-A1 Designation Series Safety door switch with key SG-B2 series • This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use. • In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. • If relays are used in the circuit between the safety switch and the load, consider the danger and use safety relays, since welding or sticking contacts of standard relays may invalidate the functions of the safety switch. • Do not place a PLC in the circuit between the safety switch and the load. Safety and security can be endangered in the event of a malfunction of the PLC. • Do not disassemble or modify the safety switch, otherwise a breakdown or an accident may occur. • Do not install the actuator in a location where the human body may come in contact. Otherwise injury may occur. SG-B2 Enable grip switch SG-C1 Emergency stop switch SG-E1 Key selector switch Key DC AC Safety door switch with key Applicable EN 1088, IEC 60947-5-1, EN 60947-5-1, standards GS-ET-19, UL 508, CSA C22.2 No.14 Standards for use IEC 60204-1, EN 60204-1 Applicable Machinery directive (2006/42/EC) directives Low voltage directive (2006/95/EC) Ambient -25 to +70 °C -13 to +158 °F (No dew condensation or icing allowed) temperature Storage: -40 to +80 °C -40 to +176 °F Ambient humidity 45 to 85 % RH Pollution degree 3 (Inside 2) Altitude 2,000 m 6,561.68 ft max. Impulse withstand 2.5 kV voltage (Uimp) Rated insulation 250 V (Note 1) voltage (Ui) 2.5 A Ambient temperature: Thermal current -25 to +60 °C -13 to +140 °F: 2.5 A max. (Ith) +60 to +65 °C +140 to +149 °F: 1.5 A max. +65 to +70 °C +149 to +158 °F: 1.0 A max. Ie Ue 30 V 125 V 250 V Rated operational Resistive load (AC-12) 2.5 A 1.5 A voltage (Ue) / Inductive load (AC-15) 1.5 A 0.75 A Rated operational Resistive load (DC-12) 2.5 A 1.1 A 0.55 A current (Ie) Inductive load (DC-13) 2.3 A 0.55 A 0.27 A Operating frequency 900 operations/hour Actuator operating speed 0.05 to 1.0 m/sec. 2,000,000 B10d (ISO 13849-1 Annex C Table C.1) Mechanical 1,000,000 operations min. (GS-ET-19) durability Rear unlocking button: 3,000 operations min. (Type SG-B2-□-L5) 100,000 operations min. (AC-12, 250 V 1 A) Electrical 1,000,000 operations min. (AC/DC 24 V 100 mA) durability (900 operations/hour) Electric shock Class II (IEC 61140) (Note 2), (double-insulated) protection class 1,400 N min. (GS-ET-19) (Note 3) Interlock force (500 N min. : SG-K24 actuator) Direct opening 11 mm 0.433 in min. (actuator: SG-K21) travel 12 mm 0.472 in min. (for other actuators) Direct opening force 80 N min. Contact resistance 700 mΩ max. (initial value, 5 m 16.404 ft cable) Protection IP 65 (IEC 60529) Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2 Vibration Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in resistance Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in Conditional 50 A (250 V) short-circuit current Short-circuit Use 250 V / 10 A fast acting type fuse protective device Material Enclosure: PA66 Cable UL style 2464, No.22 AWG 12-core Operating 2 positions specifications Mechanical 100,000 operations min. durability Key operating 10,000 operations min. durability Key tensile 1.0 N·m min. strength Direct opening 0.6 N·m min. force Direct opening 60° min. degree SG-B2-□-5: Approx. 680 g, SG-B2-□-L5: Approx. 700 g Weight Operating condition Safety door switch Safety door switch with solenoid interlock Item Precautions for proper use SG-D1 26 Notes: 1) Ratings approved by UL, c-UL: 125 V 2) Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. 3) The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. • Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. • Do not apply excessive shock to the safety switch when opening or closing the door. A shock to the safety switch exceeding 1,000 m/s2 may cause damage to the safety switch. • If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the safety switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the safety switch may affect the mechanism of the safety switch and cause a malfunction. • Cover the unused actuator entry slot using the slot plug supplied with the safety switch. • Do not store the safety switches in a dusty, humid, or organic-gas atmosphere, or in an area subjected to direct sunlight. • Use proprietary actuators only. When other actuators are used, the safety switch may be damaged. Do not cut, machine, or otherwise modify actuators. Doing so may cause equipment failure. • Do not open the lid of the safety switch. Loosening the screws may damage the safety switch. • The locking strength is rated at 1,400 N. Do not apply a load higher than the rated value. When a higher load is expected, provide an additional system consisting of another safety switch without lock or a sensor to detect door opening and stop the machine. • Regardless of door types, do not use the safety switch as a door lock. Install a separate lock using a latch or other measures. • Although the SG-K21A / SG-K22A actuators alleviate the shock when the actuator enters the slot on the safety switch, make sure that excessive shock is not applied. If the rubber bushings become deformed or cracked, replace with new ones. SG-B2 SERIES Precautions for proper use • Do not mount the safety switch facing down as shown in the figure below. Otherwise, the key may fall off due to shock. Actuator angle adjustment (vertical / horizontal) Cables When using the angle adjustable actuator (SG-K24) (Unit: mm in) M i 70 nim m um m 2. radi 75 us 6 in Door hinge (55.5 2.185) M in 70 imu m m m r 2. adiu 75 6 s in (36.2 1.425) Door hinge (231 9.094) (161 6.339) us in adi m r 7.480 imu Min 0 mm 19 dius in m ra 93 imu 6.6 Min mm 0 17 Door hinge Safety switch mounting hole (35 1.374) (Unit: mm in) Mi n 50 imu Door m m ra m d 1. ius hinge 96 9 in (36.2 1.425) Mounting (Horizontal adjustment) Safety switch mounting hole (38 1.496) SG-C1 (Vertical adjustment) • Mount the safety switch on a fixed piece of machinery or guard and the actuator on a hinged door. Avoid mounting both the safety switch and actuator on a hinged door. Doing so may cause equipment failure. For more information M M in in im to mount the devices, im the following diagram: 70 see about70 how u m um m 2. radi 75 us 6 in m m m ra .7 dius (Application Door hinge on sliding2doors) 5 6 (55.5 Door 2.185) SG-K21 Actuator SG-B2 series Safety switch Hook Door stop in Emergency stop switch s adiu 6 in m r .23 imu 10 Min mm 0 26 s in adiu m r 9.055 imu Min mm 230 (Unit: mm in) (55.5 2.185) (Vertical adjustment) Mi 50 nimum Door mm ra d hinge 1.9 ius 69 in (36.2 1.425) (40.3 1.587) SG-B2 Enable grip switch (Horizontal adjustment) When using the right-angle actuator (SG-K22) Door hinge Door hinge Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. Safety switch mounting hole Safety switch mounting hole (58 2.283) Gland (Vertical adjustment) Safety switch mounting hole (58 2.283) ius rad 1 in um .18 iM nim m 1 m 30 (48 1.890) (Horizontal adjustment) When using the safety switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (SG-K24). (41.5 1.634) Safety door switch with key Lid Minimum radius of hinged door Door hinge SG-B1 SG-A1 Safety switch mounting hole (38 1.496) • When the door hinge is on the extension line of the actuator Mi n Min i mounting 5surface: 70Door mm 2.756 in 50 mimum 0 m mum Door m radi ad m rhinge hinge hinge us of • When the door is on the extension1.9line the safety switch 1.9 ius 69 69 i i n (36.2 1.425) surface: 50 mm 1.969 n (36.2 in 1.425) Safety door switch Safety door switch with solenoid interlock • Do not fasten or loosen the gland at the bottom of the safety switch. • When bending the cable during wiring, make sure that the cable radius is kept at 30 mm 1.181 in minimum. • When wiring, make sure that water or oil does not enter the cable. • Do not open the lid of the safety switch. Otherwise the safety switch will be damaged. • Using the angle adjustment screw (M3 hexagon-socket-head screw), the actuator angle can be adjusted. (refer to the dimensions on page 29) Adjustable angle: 0 to 20° • The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the safety switch. • After adjusting the actuator angle, apply Loctite to the adjustment (Horizontal adjustment) (Vertical adjustment) screw so that the screw will not move. Door hinge (55.5 2.185) Application on hinged doors SG-K22 Actuator SG-K21S Actuator Door SG-E1 (48.2 1.898) Door hinge (231 9.094) s adiu in m r 236 imu 10. Min mm 260 s mm adiu m r : 230 5 in 5 imu Min 12 mm in: 9.0 10 mm in ters 0.472 mm: 3 2.205 20 in: 1 ters 87 Cen 0.7 Cen Door hinge Safety switch mounting hole (47 1.850) (36.2 1.425) Safety switch mounting hole Door hinge (35 1.374) (111 4.370) s adiu in m r 5.512 imu Min 0 mm 14 s mm adiu m r : 120 24 in imu m 7 Min 12 m in: 4. 70 mm in ters 0.472 m: 1 .693 m 6 20 in: ters .787 Cen 0 Cen Door hinge SG-B2 series Safety switch Recommended tightening torque for mounting screws • Recommended screw tightening torque For mounting the safety switch (M4 screw) (Note 1) (Unit: mm in) (Unit: mm in) Key selector switch When using the right-angle actuator (with rubber bushings) (SG-K22A) For mounting the actuator (SG-K21 : Two M4 screws) (Note 1) (SG-K21A / SG-K22A : Two M4 screws) (Note 1, 2) (SG-K21S : M5 screw) (Note 1) (SG-K22 : Two M4 phillips screws) (SG-K24 : Two M4 screws) (Note 1) For mounting the SG-B2 head (M3) For mounting the manual rear unlocking button (M3 screw with washers) Notes: 1) The above recommended tightening torques of the mounting screws are the values confirmed with hexagon-socket-head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. 2) In the case of SG-K21A or SG-K22A, using two M4 screws and two attached washers, fasten the actuator securely on the door. Screw tightening torque 1.8 to 2.2 N·m 1.8 to 2.2 N·m 1.0 to 1.5 N·m 4.5 to 5.5 N·m 0.8 to 1.2 N·m 1.0 to 1.5 N·m 0.9 to 1.1 N·m 0.5 to 0.7 N·m SG-D1 M4 screw Washer Rubber bushing Hinged door M4 tapped hole 27 SG-B2 SERIES Dimensions (Unit: mm in) SG-B2-K2□-5 Door switch Safety door switch Safety door switch with solenoid interlock (6.3 0.248) *Actuator center position R 1 0.08 0.039 7 35 1.378 (6.3 0.248) 0.236 ±0.039 * 20 0.787 4-holes for M4 ø4.3 ø0.169 or M4 tapped hole 6 ±1 106 4.173 145.7 5.736 76.7 3.02 53.7 2.114 5 0.197 33 1.299 40 1.575 20 0.787 Safety door switch with key 20 to 22 0.787 to 0.866 Safety switch mounting hole layout 106 4.173 R2 .2 20 0.787 36.2 1.425 33 1.299 40 1.575 1 0.039 Actuator Actuator stop (Accessory) 1 0.039 20 0.787 35 1.378 20 0.787 73.2 2.882 28 1.102 2R R2. 106 4.173 145.7 5.736 76.7 3.020 53.7 2.114 11 ±1 0.433 ±0.039 * 5 0.197 Slot plug (Note1) (Accessory) RP 41 1.614 26.4 1.039 5.2 0.205 6.2 0.244 0.0 87 1 0.039 0.9 5ø ø2 36.2 1.425 Actuator Actuator stop (Accessory) SG-B1 SG-A1 73.2 2.882 28 1.102 20 0.787 □30 □1.181 RP 26.4 1.039 42.2 1.661 6.2 0.244 5.2 0.205 84 When using horizontal mounting / straight actuator (SG-K21) SG-C1 Operation key (Accessory) 106 4.173 145.7 5.736 35 1.378 20 0.787 20 29.6 1.165 1 0.039 36.2 1.425 1 0.039 87 35 1.378 73.2 2.882 Actuator Actuator cover Actuator stop (Accessory) (6.3 0.248) (6.3 0.248) 4-holes for M4 ø4.3 ø0.169 or M4 tapped hole *Actuator center position 7.6 ±1 0.299 ±0.039 * 20 0.787 33 1.299 40 1.575 106 4.173 76.7 3.02 53.7 2.114 5 0.197 20 0.787 33 1.299 40 1.575 20 to 22 0.787 to 0.866 Safety switch mounting hole layout 5 0.197 76.7 3.020 53.7 2.114 12.6 ±1 0.496 ±0.039 * 106 4.173 145.7 5.736 1.8 0.071 16 0.630 Enable grip switch 38 1.496 0.0 20 0.787 36.2 1.425 Actuator cover Actuator Actuator stop (Accessory) Slot plug (Note1) (Accessory) RP 40.3 1.587 27.7 1.091 1 0.039 29.6 1.165 20 0.787 SG-B2 □30 □1.181 ø2 5ø 73.2 2.882 R2. 2R 0.9 84 RP 27.7 1.091 41.5 1.634 R2 .2 R 1 0.0 0.039 87 When using vertical mounting / straight actuator (SG-K22) Notes: 1) Plug the unused actuator entry slot using the plug supplied with the switch. 2) When mounting the safety switch, be sure to conform to the mounting hole dimensions and secure in place with four screws. Emergency stop switch SG-B2-K□-L5 Door switch (rear unlocking button type)  6DIHW\VZLWFKPRXQWLQJKROHOD\RXW  0     ¡¡ XQORFNLQJ 5HDU Q EXWWR UHQFH 5HIH  Actuator mounting reference position As shown in the figure on the right, the mounting reference position of the actuator when inserted in the safety switch is: The actuator stop on the actuator lightly touches the safety switch. * The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. 28 Note: Plug the unused actuator entry slot using the plug supplied with the switch.  5HDUXQORFNLQJEXWWRQ  SG-D1      ¡¡ With the mounting hole dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways. Safety switch  WR WR   “ “ 5HDUXQORFNLQJEXWWRQ $FFHVVRU\          Key selector switch   “ “  $FWXDWRU 6 < X < 23 mm 0.236 < X < 0.906 in : Not mountable 23 ≤ X ≤ 53 mm 0.906 ≤ X ≤ 2.087 in : U  se a rear unlocking button kit. (refer to page 11, 30) * The mounting part is a frame or a panel that the product is mounted on.    SG-E1 Mounting part* thickness (X):1 to 6 mm 0.039 to 0.236 in  5 5  ¡   ƑƑ      ¡ 53  When using horizontal mounting / straight actuator (SG-K21) KROHVIRU0 ¡¡RU 0WDSSHGKROH Door stop Safety switch Actuator stop (Accessory) Actuator stop (Accessory) Actuator cover Actuator SG-K21 Door stop Actuator SG-K22 SG-B2 SERIES Dimensions (Unit: mm in) SG-K2□ Actuator 4-R Actuator stop (Accessory) (Note 1) 2 0.079 10 0.394 0.8 0.031 Actuator stop (Accessory) (Note) 20 0.787 2-M4 thread 20 0.787 7.2 0.283 15 0.591 30 1.181 28 1.102 26 1.024 4.5 0.177 Actuator mounting hole layout (Straight / Right-angle actuator) 6.4 0.252 7.2 0.283 .4 -ø4 3 .17 ø0 1.6 0.063 2 2 0.079 7 8 0.0 R 33 1.299 2 0.079 15 0.591 28 1.102 20 0.787 5.2 0.205 2.2 Right-angle actuator (SG-K22) 32.4 1.276 (6 0.236) 0.8 0.031 6.2 0.244 Safety door switch Safety door switch with solenoid interlock Straight actuator (SG-K21) SG-B1 SG-A1 Safety door switch with key Actuator cover 2 0.079 12 0.472 * Mounting pitch can be widened to 20 mm 0.787 in by moving the rubber bushings. Rubber bushing (20 0.787) 12 0.472 .16 9 ø0 * When the mounting pitch is 12 mm 0.472 in (factory setting), the actuator has movement flexibility to the directions shown in Ⓐ and Ⓑ . * When the mounting pitch is 20 mm 0.787 in, the actuator has movement flexibility to the directions shown in Ⓑ. Side the rubber cushions together with the screws. 4.3 0.8 0.031 When mounted (5 0.197) Ⓑ 2-ø9 ø0.354 Rubber bushing Washer (Accessory) 0.8 0.031 Ⓑ Actuator stop (Accessory) (Note) SG-B2 Enable grip switch When mounted (5 0.197) 2-M4 thread ) Ⓐ 2-ø ( When mounted (39.7 1.563) 0.8 0.031 15 0.591 Actuator mounting hole layout Straight actuator with rubber bushings, Right-angle actuator with rubber bushings When mounted (11.2 0.441) 2 0.079 15 0.591 30 1.181 (20 0.787) 12 0.472 * Mounting pitch is set to 12 mm 0.472 in in factory. When setting the mounting pitch to 20 mm 0.787 in, widen the pitch of rubber cushions to 20 mm 0.787 in. * The actuator has movement flexibility to the directions shown in Ⓑ. Actuator stop (Accessory) (Note) Washer (Accessory) 2-ø10 ø0.394 Right-angle actuator with rubber bushings (SG-K22A) 2-ø10 ø0.394 43.8 1.724 15.3 0.602 0.8 0.031 15.8 0.622 2-ø9 8.5 0.335 ø0.354 7.3 0.287 4.3 ø0. 169 30 1.181 Straight actuator with rubber bushings (SG-K21A) 2-ø Slide actuator (SG-K21S) 14 0.551 2-ø5.2 51 2.008 6-M5 thread 32.5 1.280 35 1.378 6 0.236 Actuator material: Stainless steel (SUS) Thickness: 2.5 0.098 34 1.339 30.5 1.201 16 0.630 15 0.591 18 (40 1.575) 30.7 1.209 0.709 3 0.118 75 2.953 SG-C1 Emergency stop switch 2.5 0.098 Actuator mounting hole layout 5 ø0.20 34 1.339 48.5 1.909 56 2.205 5 37.5 1.476 0.197 19 0.748 8-R2.6 R0.1 02 26.5 1.043 2.5 13 0.512 0.098 Body material: Stainless steel (SUS) Horizontal / Vertical angle adjustable actuators (SG-K24) 3 Horizontal 0.118 adjustment 20° 15 0.591 7 0.276 18.5 0.728 29 1.142 1 0.039 (Vertical adjustment) Orienting insert Actuator stop (Accessory) (Note) R (Ho 2.1 R0. le fo 083 r M4 ) 3.6 0.142 Changes in the orientation of adjustment for angle adjustable (vertical / horizontal) actuators The orientation of adjustment of angle adjustable (vertical / horizontal) actuators is determined by the position in which the orienting insert (white plastic) is installed on the back of the actuator. Install the insert according to the desired orientation of adjustment. Exercise care not to lose the orienting insert. The actuator will not operate properly without the orienting insert. SG-E1 Key selector switch 49 1.929 Orienting insert 23 0.906 26 1.024 38 1.496 Angle adjustable screw (M3 hexagon-socket-head screw) Actuator stop (Accessory) (Note) Actuator mounting hole layout horizontal / vertical angle adjustable actuators 2-M4 thread 38 1.496 SG-PH2 Padlock hasp (Optional) 0.8 0.031 2-R Note: The actuator stop is used to adjust the actuator position. Remove the actuator stop after the actuator position is mounted. 4R 0.1 57 ø8 2- 15 SG-D1 ø 3 0. 28 1.102 16.5 0.650 20° 2 0.079 Angle adjustable screw (M3 hexagon-socket-head screw) 8 0.315 60 2.362 29 SG-B2 SERIES Dimensions (Unit: mm in) 10 0.394 .13 0 When installing the SG-B2-K2□-L5 (rear unlocking button type), provide a rear unlocking button a hole on the MS-SG21. 3.3 R0 (40 1.575) 13.4 0.528 4-M4 thread Material: Anodized aluminum A6063 Weight: Approx. 180 g 20 to 22 0.787 to 0.866 4-M4 thread C3 4- .118 C0 22 0.866 SG-B2 ø fo 18 bu r re ø0 tto ar .70 n u 9 (N nlo ho ot ck le e) in g 106 4.173 187 7.362 170 6.693 Safety door switch with key 6.4 4-R 252 R0. (187 7.362) 21 0.827 ø18 ø0.709 hole for rear unlocking button (Note) 106 4.173 read 21 0.827 64.1 2.524 4 th Safety switch mounting hole layout 4-R 40 1.575 (13.4 0.528) 4-M SG-B1 SG-A1 Mounting plate hole layout 42.2 1.661 50.7 1.996 2-12.8 0.504 2-6.6 0.260 6 0.236 Safety door switch Safety door switch with solenoid interlock MS-SG21 Mounting plate (Optional) Note: With the mounting hole dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways. Enable grip switch MS-SG-22 / MS-SG-23 Rear unlocking button kit for a frame (Optional) Rear unlocking button mounting dimensions Button (PA66) Hinge + plate [Stainless steel (SUS)] 2 or 4-M4 thread Button pressed (unlocked) 16 0.630 27.3 1.075 Button released 33 1.299 16 to 30 0.63 to 1.181 30 1.181 Safety door switch with key SG-B2 series Pin [Stainless steel (SUS)] Total thickness of mounting frame, panel, and mounting plate: 23 to 43 mm 0.906 to 1.693 in SG-E1 Key selector switch Connection link material: Stainless steel (SUS) Example: When mounted on a □30 mm □1.181 in frame using the mounting plate above MS-SG-21, select MS-SG-22 since the mounting part thickness (X) is 40 (X = 10 + 30 = 40) 1.575 (X = 0.394 + 1.181 = 1.575). For more information about selecting a back manual unlocking button kit for a frame, see the following table: Mounting part* thickness (X) (mm in) Screw: Steel SG-D1 Model No. Rear unlocking button type When installing an SG-B2-K2□D-L5 with a rear unlocking button directly MS-SG-22 33 < X ≤ 43 1.299 < X ≤ 1.693 MS-SG-23 23 < X ≤ 33 0.906 < X ≤ 1.299 * The mounting part is a frame or a panel that the product is mounted on. Note: With the mounting hole dimension, the rear unlocking button rod does not touch the hole even when the safety switch moves sideways. 30 60.5 2.382 for n ole tto 9 h g bu 0 7 n 0. ki 8 ø loc ø1 ar un re ote) (N 25.5 1.004 60.5 2.382 25.5 1.004 33 1.299 31.5 1.240 Emergency stop switch 21.3 0.839 73 2.874 75 ø1.5 SG-C1 ø40 ø10.4 ø0.409 40 1.575 SG-C1 SERIES Enable grip switch Designation Series Applicable standards Standards for use Ambient temperature DC AC DC AC DC AC DC B10d Indicator (Note) Weight 50 A (250 V) 250 V AC, 10 A Fuse (IEC60127-1) 60 N min. (Push monitor switch) 4.7 mm 0.185 in min. (Push monitor switch) 500 N min. (Grip switch) Green LED Rated Operating Voltage: DC 24 V ±10 % Rated current: 15 mA SG-C1-21: Approx. 140 g SG-C1-21-E: Approx. 150 g SG-C1-21-EG: Approx. 155 g SG-C1-21-MM: Approx. 155 g SG-C1-21-EMM: Approx. 165 g SG-C1-21-EMK: Approx. 170 g Note: As for the type with pilot light, Ue (contact ratings) of all switches is only less than 30 V DC, and connect all switches to SELV (safety extra low voltage) or PELV (protective extra low voltage) circuit. SG-B2 SG-C1 SG-E1 Key selector switch Mechanical durability Electrical durability Shock resistance Free fall Vibration resistance IP66 / IP67 Protection IP65 Conditional shortcircuit current Short-circuit protective device Direct opening force Direct opening travel Actuator Strength (Entire button is pushed) • Use proper size wires to meet voltage and current requirements. • Do not apply an excessive shock to the SG-C1 series. • When wiring, prevent dust, water, or oil from entering the grip switch. • If used in wet locations, this device must be used with cable suitable for wet locations. • When multiple safety components are connected in series, the EN ISO 13849-1 performance level will fall due to the deterioration in fault detection functionality. • The suitability of control systems in which this product has been embedded must be verified in accordance with EN ISO 13849-2. • SG-C1 series is a device used for enabling a machine (robot, etc.) when teaching the machine in a hazardous area manually. Configure the enabling system so that the machine can operate when the switch is in position 2 and an additional “start” is pushed to initiate the operation. • In order to ensure safety of the control system, connect each pair of the contacts of the 3 position enabling switch (terminal No. NO1-C1 and NO2-C2) to a discrepancy detection circuit such as a safety relay module. (ISO13849-1) • The base and the plastic part of rubber boot frame are made of glass-reinforced ABS / PBT. The rubber boot is made of silicone rubber. The screw is made of iron. When cleaning the SG-C1 series, use a detergent compatible with the materials • As for momentary pushbutton switch and key selector switch of additional control unit, do not connect NO and NC contacts of a microswitch to different voltages or different power sources to prevent a dead short-circuit. • Do not operate key selector switch of additional control unit without completely insertion of the key. • The rubber boot may deteriorate depending on the operating environment and conditions. SG-B1 SG-A1 Emergency stop switch Electric shock protection class Operating frequency • In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. • Do not disassemble or modify the grip switch. • When using the SG-C1 series for safety-related equipment in a control system, refer to the safety standards and regulations in each country and region depending on the application purpose of the actual machines and installations to make sure of correct operation. Also, perform risk assessment to make sure of safety before starting operation. • Do not tie the grip switch around the button with a tape or string to keep the switch in position 2. Doing so will prevent the grip switch from functioning as designed and is extremely dangerous. Systems that stop operation after the grip has been operated for a certain period of time and require the operator to grip it again are effective in preventing circumvention of the device’s intended purpose. • Please note that permanent installation of the grip switch at the machine is inadmissible. Enable grip switch Rated operational voltage (Ue) / Rated operational current (Ie) (Note) Grip switch AC Ambient humidity Pollution degree Altitude Impulse withstand voltage (Uimp) Rated insulation voltage (Ui) Thermal current (Ith) IEC 60947-5-1, EN 60947-5-1, JIS C 8201-5-1, GS-ET-22, UL 508, CSA C22.2 No.14 ISO 12100 / EN ISO 12100, IEC 60204-1 / EN 60204-1, ISO 11161 / EN ISO11161, ISO 10218-1 / EN ISO 10218-1, ANSI/RIA/ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19, ISO 13849-1 / EN ISO 13849-1 Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) -25 to +60 °C -13 to +140 °F (No dew condensation or icing allowed) Storage: -40 to +80 °C -40 to +176 °F 45 to 85 % RH 3 (Inside 2) 2,000 m 6,561.68 ft max. 2.5 kV (Momentary pushbutton switch and key selector switch: 1.5 kV) 250 V (Momentary pushbutton switch and key selector switch: 125 V) / Models with indicator: 30 V 3 A (Emergency stop switch: 5 A) Ie Ue 30 V 125 V 250 V Resistive load (AC-12) - 1 A 0.5 A 3 position Inductive load (AC-15) - 0.7 A 0.5 A enabling switch (Terminal No.: Resistive load (DC-12) 1 A 0.2 A NO1-C1, NO2-C2) Inductive load (DC-13) 0.7 A 0.1 A Resistive load (AC-12) - 2.5 A 1.5 A Inductive load (AC-15) - 1.5 A 0.75 A Push monitor switch (Terminal No. 31-32) Resistive load (DC-12) 2.5 A 1.1 A 0.55 A Inductive load (DC-13) 2.3 A 0.55 A 0.27 A Resistive load (AC-12) - 5 A 3 A Emergency stop Inductive load (AC-15) - 3 A 1.5 A switch Resistive load (DC-12) 2 A 0.4 A 0.2 A (Terminal No. 1-2, 1-2) Inductive load (DC-13) 1 A 0.22 A 0.1 A Momentary pushbutton switch Resistive load (AC-12) - 0.5 A / Key selector switch Inductive load (AC-15) - 0.3 A (Terminal No. C1 NO1 NC1, Resistive load (DC-12) 1 A 0.2 A C2 NO2, Inductive load (DC-13) 0.7 A 0.1 A NC2 ) Class II (IEC 61140), (double insulated) (Models with indicator: Class III) 1,200 operations/hour 2,000,000 (ISO 13849-1 Annex C Table C.1) Position 1⇒2⇒1: 1,000,000 operations min. Position 1⇒2⇒3⇒1: 100,000 operations min. 100,000 operations min. (Rated operating load) 1,000,000 operations min. (AC / DC 24 V 100 mA) Malfunction: 150 m/s2, Destruction: 1,000 m/s2 1.0 m 3.281 ft 1 time (Based on IEC60068-2-32) Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 16.7 Hz, half amplitude 1.5 mm 0.059 in Without additional switch and pilot light With additional switch and/or pilot light • This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use. Safety door switch with key Operating condition Applicable directives Enable grip switch SG-C1 series Safety door switch Safety door switch with solenoid interlock Item Precautions for proper use Cable glands • The product includes one cable gland. When purchasing replacements, ensure that they conform to the following dimensional range: • Dimension diagram Threaded part (M16 × 1.2 mm 0.047 in) 15 mm 0.591 in max. 22 mm 0.866 in max. Specifications SG-D1 Cable gland • Waterproofness: Use a cable gland that can maintain performance of IP67 or higher. • Recommended connector: Model SKINTOP-BS-M16 × 1.5-B (manufactured by LAPP in Germany and imported by K.mecs Co., Ltd.) • Applicable cable diameter: Outer diameter of 4.5 to 10 mm 0.177 to 0.787 in 31 SG-C1 SERIES Precautions for proper use Dimensions (Unit: mm in) Wire length inside the grip switch SG-C1-□ Enable grip switch SG-B1 SG-A1 Sheath Indicator Momentary pushbutton switch / Key selector switch Emergency stop switch Safety door switch with key Emergency stop switch 83 3.268 Emergency stop 50 1.969 62 2.441 switch Grip switch 16 0.630 L + 115 4.528 SG-C1-21 134 5.276 5 mm 0.197 in Indicator 78 3.071 Momentary pushbutton switch Grip switch (64 2.52) Safety door switch Safety door switch with solenoid interlock Momentary Emergency Wire pushbutton switch Grip switch stop switch stripping / Key selector switch length NO1 C1 31 32 NO2 C2 C NO NC 1 2 40 45 50 60 85 80 120 110 L (mm in) 1.575 1.772 1.969 2.362 3.346 3.150 4.724 4.331 (94 3.701) Cable gland (Accessory) Applicable wire size in terminal SG-B2 Emergency stop switch • If direct-mounted: 0.5 mm2 (AWG20) or less Wire SG-C1 series according to IEC60204-1 Wiring Instruction 16 0.630 SG-C1-21-E / SG-C1-21-EG Enable grip switch A 1.1 to 1.3 N·m SG-C1-21-EMK Emergency stop switch Key selector switch Rubber boot Cable gland SG-C1-21-EMM B C A (M4 screw × 4) Base Key selector switch B 2.7 to 3.3 N·m C 2.7 to 3.3 N·m The B and C values in the above table reflect use of the recommended connectors listed above. When using a cable gland other than the recommended model, check that part’s tightening torque. 78 3.071 4 0.157 11 0.433 16 0.630 Emergency stop switch SG-E1 For mounting rubber boot frame on the base (M4 screw × 4) Cable gland to Grip switch Screw Cable gland to cable gland Screw Screw tightening position torque Note: Not included in SG-C1-21-E. Momentary pushbutton switch Recommended screw tightening torque Part being secured Indicator (Note) Emergency stop switch 16 0.630 SG-C1 • Solder the terminal at 310 to 350 °C 590 to 662 °F within 3 seconds using a 60 W soldering iron. Sn-Ag-Cu type is recommended when using lead free solder. • When soldering, do not touch the SG-C1-□ with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. • Use non-corrosive rosin flux. • Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit. • When using a stranded wire, make sure that adjoining terminals are not short-circuited with protruding core wires. • Use copper wire 60 to 75 °C 140 to 167 °F only. (UL508) • The wiring has to be installed according to GS-ET-22, 4.2.6. 5 0.197 Wiring 78 3.071 78 3.071 Base Momentary pushbutton switch SG-C1-21-MM SG-D1 16 0.630 75 2.953 Emergency stop switch 78 3.071 32 Indicator (Note) 5 0.197 Momentary pushbutton switch Note: Not included in SG-C1-21-E. SG-E1 Pushbutton type SERIES Emergency stop switch Specifications Designation Pushbutton type emergency stop switch Series SG-E1 series JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) -25 to +60 °C -13 to +140 °F (No dew condensation or icing allowed) Storage: -40 to +80 °C -40 to +176 °F Ambient humidity 45 to 85 % RH Pollution degree 3 Altitude 4 kV Rated insulation voltage (Ui) 600 V ø22.3 +0.4 0 ø0 .87 8 0+0.016 10 A Ue 24 V 48 V 50 V 110 V 220 V 440 V Resistive 10 A load (AC-12) - 10 A 10 A 6 A 2 A Inductive load (AC-15) 10 A (A600) - 7A 5A 3A 1A Resistive 8A 4A load (DC-12) - 2.2 A 1.1 A - Inductive load (DC-13) 4 A 2 A (P600) - 1.1 A 0.6 A - Contact resistance 50 mΩ max. (initial value) Insulation resistance 100 MΩ min. (500 V DC megger) Class II (IEC 61140) II (IEC60664-1) Reset action Turn reset Protection Front of the panel: IP65 (IEC 60529) Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2 Vibration resistance B10d Mechanical durability Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in 100,000 (ISO 13849-1 Annex C Table C.1) 500,000 operations min. 500,000 operations min. (900 operations/hour) Material Actuator: PA6, Contact block: PA66 Terminal screw (M3.5 philips & flathead ) Max. 2 mm2 (Single core ø1.6 ø0.063 max.) 2 wires max. Tightening torque of the terminal screws 1.0 to 1.3 N·m Tightening torque of the locking ring 2.0 N·m Weight Accessory SG-E1-02-□: Approx. 60 g, SG-E1-12-□: Approx. 75 g Lever lock: 1 pc SG-B2 • The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. Applicable wiring (1) The applicable wire size is 2 mm2 maximum. (single wire ø1.6 mm ø0.063 in maximum) One or two wires can be connected. • Applicable crimping terminal (Unit: mm in) When using direction Ⓐ SG-C1 ø3.6 ø0.142 min. Ⓐ Ⓐ 8 0.315 max. 4 0.157 max. Ⓑ Ⓑ Ⓑ Ⓑ 6 0.236 min. When using direction Ⓑ ø3.6 ø0.142 min. 6.6 0.260 max. 4 0.157 max. Ⓐ 6 0.236 min. SG-E1 Be sure to use an insulation tube or cover on the crimping part of the crimping terminal to prevent electrical shocks. • Single wire (Unit: mm in) Key selector switch Applicable wire size +0.008 Ⓐ Electrical durability Connecting method +0.2 Emergency stop switch Overvoltage category The 3.2 0 0.126 0 recess is for preventing rotation and not necessary when anti-rotation is not used. When anti-rotation is not required or when the panel cut-out does not have anti-rotation recess, remove the “Projection” using pliers. ø1.6 ø0.063 max. Electric shock protection class 50 1.969 Note: When using the safety lever lock, determine the vertical spacing* in consideration of convenience for installing and removing the safety lever lock. (Recommended vertical spacing: 100 mm 3.937 in or more) Enable grip switch DC AC Ie (mm in) +0.008 *3.2+0.2 0 0.126 0 (45 min.) Thermal current (Ith) R0.8 R0.031 max. SG-B1 SG-A1 Safety door switch with key Impulse withstand voltage (Uimp) Rated operational voltage (Ue) / Rated operational current (Ie) Mounting hole layout / minimum mounting center 2,000 m 6,561.68 ft max. +0.016 24.1+0.4 0 0.949 0 Ambient temperature 50 1.969 (*) Operating condition Applicable standards • In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. • Use wiring that is appropriate for the applied voltage and energized current, and tighten terminal screws (M3.5) to the recommended tightening torque (1.0 to 1.3 N·m). Using the switch when the screws are loose will cause it to become extremely hot, posing the risk of fire. Safety door switch Safety door switch with solenoid interlock Item Precautions for proper use 8 0.315 max. Note: W  hen connecting wires to contact blocks or transformers in the direction Ⓑ, keep the insulation stripping length 6.6 mm 0.260 in at the maximum. (2) Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m. SG-D1 Using the lever lock • Panasonic Industrial Devices SUNX strongly recommends using the lever lock (yellow) to prevent heavy vibration or maintenance personnel from unlocking the contact assembly. 33 SG-E1 SERIES Dimensions (Unit: mm in) 5XEEHUJDVNHW 0RXQWLQJSDQHOWKLFNQHVVWRWR /RFNLQJOHYHU 1RWH /RFNLQJULQJ /HYHUORFN 1RWH 7HUPLQDOVFUHZ 0 /2 SG-B1 SG-A1 FRQWDFWEORFNV FRQWDFWEORFNV  FRQWDFWEORFNV   FRQWDFWEORFNV   &. ¡¡ 'XPP\EORFN  Safety door switch Safety door switch with solenoid interlock SG-E1-□ Emergency stop switch   Safety door switch with key Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever. SG-E1-□-E SEMI emergency off (EMO) switch 5XEEHUJDVNHW 0RXQWLQJSDQHOWKLFNQHVVWRWR /RFNLQJOHYHU 1RWH /RFNLQJULQJ /HYHUORFN 1RWH 7HUPLQDOVFUHZ 0 /2 Enable grip switch FRQWDFWEORFNV FRQWDFWEORFNV  FRQWDFWEORFNV   FRQWDFWEORFNV    SG-B2  &. ¡¡ 'XPP\EORFN   Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever. SG-EP□ Emergency stop nameplate (Optional) SG-C1 62 2.3 0ø ø6 Emergency stop switch ø2 SG-ET1 Locking ring wrench (Optional) 2ø 110 4.331 66 1.0 0.039 Height of SEMI emergency off (EMO) switch and SEMI guard ring MS-SG-GR1 SEMI guard ring (Optional) SG-E1 As illustrated below, the height of the SEMI emergency off (EMO) switch and SEMI guard ring should be 3 mm 0.118 in or less. 35 1.378 A (Note) 25 0.984 0.8 ø74 ø2.913 ø66 ø2.598 66 52 2.047 Key selector switch 2ø ø 02 .1 ø1 0.8 1.5 0.059 ø2 28 3 mm 0.118 in max. SG-D1 42 1.654 T = 2.0 0.079 Note: When anti-rotation is not required or when the panel cut-out does not have an anti-rotation recess, remove part “A” of the SEMI guard ring using pliers. 34 • Note The EMO switch and the guard ring have been designed for applications in semiconductor manufacturing equipment only. Do not use EMO switch and/or the guard ring which are installed on machine tools or food processing machines. (Machinery Directive of the European Commission and IEC 602041 require that emergency stop switches be installed in a readily accessible area and the usage of switch guards is not permitted.) SG-D1 SERIES Key selector switch Specifications JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) -25 to +60 °C -13 to +140 °F (No dew condensation or icing allowed) Storage: -40 to +80 °C -40 to +176 °F Ambient temperature Ambient humidity 45 to 85 % RH Pollution degree 3 Altitude Rated insulation voltage (Ui) 600 V ø22.3 +0.4 0 ø0 .87 8 0+0.016 10 A Ue 24 V 48 V 50 V 110 V 220 V 440 V Resistive 10 A load (AC-12) - 10 A 10 A 6 A 2 A Inductive load (AC-15) 10 A (A600) - 7A 5A 3A 1A - 2.2 A 1.1 A - Inductive load (DC-13) 4 A 2 A (P600) - 1.1 A 0.6 A - 50 mΩ max. (initial value) Insulation resistance 100 MΩ min. (500 V DC megger) Class II (IEC 61140) II (IEC60664-1) Mechanical durability Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in 100,000 (ISO 13849-1 Annex C Table C.1) Material Actuator: PA6, Contact block: PA66 Tightening torque of the locking ring Ⓐ Ⓐ 8 0.315 max. 4 0.157 max. Ⓑ Ⓑ Ⓑ Ⓑ 6 0.236 min. When using direction Ⓑ ø3.6 ø0.142 min. Terminal screw (M3.5 philips & flathead ) Max. 2 mm2 (Single core ø1.6 ø0.063 max.) 2 wires max. 1.0 to 1.3 N·m 2.0 N·m Ⓐ 4 0.157 max. Ⓐ 6 0.236 min. Be sure to use an insulation tube or cover on the crimping part of the crimping terminal to prevent electrical shocks. • Single wire (Unit: mm in) 8 0.315 max. Selector behavior 2 positions Note: W  hen connecting wires to contact blocks or transformers in the direction Ⓑ, keep the insulation stripping length 6.6 mm 0.260 in at the maximum. Minimum direct opening operating angle 90° (2) Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m. Minimum direct opening torque 0.4 N·m Maximum operation angle 90° Weight Accessory SG-E1 Key selector switch Tightening torque of the terminal screws SG-C1 ø3.6 ø0.142 min. 6.6 0.260 max. 100,000 operations min. (1,200 operations/hour) Applicable wire size (1) The applicable wire size is 2 mm2 maximum. (single wire ø1.6 mm ø0.063 in maximum) One or two wires can be connected. • Applicable crimping terminal (Unit: mm in) When using direction Ⓐ 100,000 operations min. Electrical durability Connecting method Applicable wiring ø1.6 ø0.063 max. B10d +0.008 • The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. Front of the panel: IP65 Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2 Vibration resistance +0.2 Emergency stop switch Protection The 3.2 0 0.126 0 recess is for preventing rotation and not necessary when anti-rotation is not used. SG-B2 Resistive 8A 4A load (DC-12) Contact resistance Overvoltage category 30 1.181 Note: When using the safety lever lock, determine the vertical spacing* in consideration of convenience for installing and removing the safety lever lock. (Recommended vertical spacing: 100 mm 3.937 in or more) Enable grip switch DC AC Ie (mm in) +0.008 *3.2+0.2 0 0.126 0 (45 min.) Thermal current (Ith) R0.8 R0.031 max. SG-B1 SG-A1 Safety door switch with key 4 kV Electric shock protection class Mounting hole layout / minimum mounting center 2,000 m 6,561.68 ft max. Impulse withstand voltage (Uimp) Rated operational voltage (Ue) / Rated operational current (Ie) • In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the safety switch. • Use wiring that is appropriate for the applied voltage and energized current, and tighten terminal screws (M3.5) to the recommended tightening torque (1.0 to 1.3 N·m). Using the switch when the screws are loose will cause it to become extremely hot, posing the risk of fire. 50 1.969 (*) Operating condition Applicable standards Key selector switch SG-D1 series +0.016 24.1+0.4 0 0.949 0 Designation Series Safety door switch Safety door switch with solenoid interlock Item Precautions for proper use SG-D1 Using the lever lock (accessory) • Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever. SG-D1-2□11: Approx. 75 g, SG-D1-2□22: Approx. 95 g Key: 2pcs., Lever lock: 1 pc. 35 SG-D1 SERIES Dimensions (Unit: mm in) SG-D1-□ Key selector switch Mounting panel thickness: 0.8 to 6 0.031 to 0.236 Rubber gasket M3.5 M0.138 Terminal screw Contact block Locking lever (Note) Lever lock (Note) LO CK 2 contact blocks / 4 contact blocks 48.5 1.909 (2 contact blocks), 68.5 2.697 (4 contact blocks) 14.4 0.567 49.4 1.945 (2 contact blocks), 69.4 2.732 (4 contact blocks) 41.4 1.630 25 0.984 26.5 1.043 ø2 9. 4 Locking ring ø1 .1 57 0.5 0.020 29.4 1.157 37.4 1.472 Note: Please attach the lever lock (yellow) after locking to prevent personnel from forgetting to lock the lock lever. SG-ET1 Locking ring wrench (Optional) 110 4.331 8 ø2 02 .1 ø1 Please contact .......... 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Global Sales Department ■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved © No. CE-NSDLU-5 July, 2013 Specifications are subject to change without notice. 2013 Printed in Japan
SG-B1-SA-G1 价格&库存

很抱歉,暂时无法提供与“SG-B1-SA-G1”相匹配的价格&库存,您可以联系我们找货

免费人工找货