High Speed • High Accuracy Eddy Current Type Digital Displacement Sensor
GP-X
SERIES
Conforming to
EMC Directive
25!s & 0.02%F.S.
High-speed sampling and high resolution.
The new choice for even more variegated data collection and processing.
The unique sensing technology developed by our SUNX team has made possible
an ultra-high speed minute displacement measurement function, essential for
high-precision processes, that boasts the highest resolution in the industry.
With a 25 !s ultra high sampling speed, the GP-X series won’t miss
even high speed work displacements.
These devices boast a 0.07 % F.S. / C
temperature characteristics
They perform with a 0.3 %F.S.
linearity for stainless steel and iron
Because they perform with a 0.3 % F.S. linearity, they can be used for
sensing stainless steel and iron enabling precise measurements not affected by
the work’s material. Specifications corresponding to each material (stainless
steel, iron, aluminum) has already been inputted in the controller enabling the
easy selection of the setting that is most suitable for the particular material used.
Optimal correction of the output feature
By combining the sensor head with the controller, we’ve realized
0.07 % F.S. / C. They are highly resistant to ambient temperature
changes enabling stable micro-displacement measurements.
With the industry’s highest resolution, 0.02 % F.S. (Note), they can
perform high-accuracy measurements of micro-displacements.
(Average number of samples: 64)
Note: GP-XC3SE and GP-XC5SE Resolution: 0.04 %F.S.
1
Stainless steel
Output value
They possess a 0.02 % F.S. resolution
for highly accurate measurement
Aluminum
Iron
Distance
Before correction
Output value
We’ve realized a 25 ¨s (40,000
times / sec.) ultra high sampling speed
Distance
After correction
A total of 6 types of sensor head
6 types of sensor heads from the ultra compact "3.8 mm "0.150 in cylindrical type to the
long range sensing "22 mm "0.866 in / M12 screw type are available.
GP-X22KL
Sensing range : 0 to 10 mm
0 to 0.394 in
Appearance : "22 mm / M12
"0.866 in
Controller
NPN output type , PNP output type
GP-X12ML
Sensing range : 0 to 5 mm
0 to 0.197 in
Appearance : M12
DIN 48 mm 1.890 in size
GP-X10M
GP-X3SE
GP-X5SE
GP-X8S
Sensing range : 0 to 2 mm
0 to 0.079 in
Appearance : M10
Sensing range : 0 to 0.8 mm
0 to 0.031 in
Appearance : "3.8 mm
"0.150 in
Sensing range : 0 to 1 mm
0 to 0.039 in
Appearance : "5.4 mm
"0.213 in
Sensing range : 0 to 2 mm
0 to 0.079 in
Appearance : "8 mm
"0.315 in
Sensor heads with superior workability and maintainability
Replacement of sensor heads possible
One-touch connector hook up
Sensor head extensions possible
As a result of damage or other mishap
rendering maintenance necessary, you
can replace only the sensor head leaving
the controller as it is.
The sensor head and the controller connection
is a simple one-touch connector type.
Between the sensor head and the
controller, a GP-XCCJ7 extension cable
(optional) can be used up to a 10 m
32.808 ft total length.
One-touch
connector
Sensor head
Extension Cable
GP-XCCJ7 : 7 m 22.966 ft
Sensor cable : 3 m
9.843 ft
Total length : 10 m
32.808 ft
2
The SUNX sensor design policy has realized controllers
that are easy to use on-site.
Panel mounting type
Controller
Compact type DIN 48 mm 1.890 in size
Out of setting range
(upper threshold)
Sensing values within
setting range
Out of setting range
(lower threshold)
The 5-digit, dual, 2-color
digital display offers great
visibility
If the measurement results fall within the
setting range (GO), they will appear on the
lower digital display in green. If they are out
of range (HI, LO), they will be displayed in
the upper digital in orange. The display
position and color change allows for
accurate visibility even for momentary
changes.
Sensing values
Simple setting mode
Manual mode
Setting value verifiable
even in sensing mode
Upper threshold value
Digital input display
enabling easy setting
Its dual digital display enables numerical
setting while verifying setting items for each
mode. Even when sensing, it enables the
verification of the main settings.
3
Average number of
samples setting value
Lower threshold value
Various functions made available through
the use of RS-232C standard interfaces.
Exclusive RS-232C cable
(Accessory for the intelligent monitor GP-XAiM)
Cable length : 3 m 9.843 ft
[PC side connector : D-SUB (9 pins)]
Link cable for controller communication
unit (optional) SL-F
Cable length : 150 mm 5.906 in,
250 mm 9.843 in,
1,000 mm 39.370 in
Controller
communication unit
GP-XCOM
The RS-232C communication
connector is standard equipment
It is capable of various controls such as saving
measurement data to PC and the controller’s inputted
settings and loading stored memory.
Connector for RS-232C
communication
5
Intelligent monitor (GP-XAiM) optimal for
collecting and analyzing measurement data.
(Exclusive RC-232C cable is attached)
An intelligent monitor capable of the settings for each measurement
conditions and waveform display monitoring. It can perform
waveform monitoring, which could until now only be done by the
oscilloscope, as well as the simple loading and saving onto a PC of
settings for each condition and function.
Sensor A and sensor B
can be linked together
and measurement can
be calculated (a – b) to
detect difference in
object.
Sensor B
Sensor A
3-value judgment output for calculating measurement data
conformity and calculation results between 2 interconnected
controllers is rendered possible. The calculation function equipment
renders digital panel controllers unnecessary.
b
(a – b)
a
object
Enables sensors data comparisons
and calculations
(a – b) : difference in object
Datalink between sensors possible
The controller communication unit GP-XCOM (optional) can be
linked to up to 8 controllers and load via just one RS-232C cable
each controller settings and measurement data to a PC.
Maximum of eight controllers
Controller communication unit
Link cable
Data sent to
a PC via the
RS-232C
6
GP-X
ORDER GUIDE
Appearance (mm in)
Type
Sensor heads
Non-threaded type sensor head
"3.8
"0.150
0 to 0.8 mm
0 to 0.031 in
17
0.669
"5.4
"0.213
0 to 1 mm
0 to 0.039 in
17
0.669
83
3.268
"8
"0.315
Threaded type sensor head
Sensing range
Controller
17
0.669
48
1.890
0 to 2 mm
0 to 0.079 in
48
1.890
M10
17
0.669
M12
0 to 2 mm
0 to 0.079 in
0 to 5 mm
0 to 0.197 in
21
0.827
0 to 10 mm
0 to 0.394 in
M12
"22
0.866
35
1.378
Set Model No.
(Sensor head model No.)
Comparative output
GP-XC3SE
(GP-X3SE) (Note)
NPN open-collector
transistor
GP-XC3SE-P
(GP-X3SE) (Note)
PNP open-collector
transistor
GP-XC5SE
(GP-X5SE) (Note)
NPN open-collector
transistor
GP-XC5SE-P
(GP-X5SE) (Note)
PNP open-collector
transistor
GP-XC8S
(GP-X8S)
NPN open-collector
transistor
GP-XC8S-P
(GP-X8S)
PNP open-collector
transistor
GP-XC10M
(GP-X10M)
NPN open-collector
transistor
GP-XC10M-P
(GP-X10M)
PNP open-collector
transistor
GP-XC12ML
(GP-X12ML)
NPN open-collector
transistor
GP-XC12ML-P
(GP-X12ML)
PNP open-collector
transistor
GP-XC22KL
(GP-X22KL)
NPN open-collector
transistor
GP-XC22KL-P
(GP-X22KL)
PNP open-collector
transistor
Note: High resolution types (GP-XC3S, GP-XC5S: 0.02 % F.S., average number of samples: 64) are available. These products correspond to the Export
Trade Administration Act of Japan. Shipping them outside Japan requires special permission from the Japanese government regarding stipulations in
Foreign Exchange and Foreign Trade Law. Please contact our office for details.
OPTIONS
Designation
Model No.
Description
BCD output unit
GP-XBCD
This unit outputs measurement values in BCD data format at a high speed.
• Sampling frequency : 20 kHz
Cable with connector
on one end for
BCD output unit
GP-XBCC3
Length: 3 m 9.843 ft
Controller
communication unit
GP-XCOM
Up to 8 controllers can be linked.
SL-F150
Length: 150 mm 5.906 in
SL-F250
Length: 250 mm 9.843 in
SL-F1000
Length: 1,000 mm 39.370 in
Intelligent monitor
GP-XAiM
Monitoring settings for each measurement condition and measurement
waveforms is enabled by way of a PC.
• One exclusive RS-232C cable (3 m 9.843 ft length) is attached.
Extension cable for
sensor head
GP-XCCJ7
Length: 7 m 22.966 ft
Link cable for
controller
communication unit
BCD output unit
Cable with connector on
one end for BCD
output unit
7
This cable links the controller communication
units. Select as per the cable length.
This cable with connector is for extensions
between the sensor head and controller.
Controller communication unit Intelligent monitor
• GP-XAiM
Link cable for controller
communication
unit
BCD output unit
GP-XBCD
Cable with connector on one end
for BCD output unit GP-XBCC3
Cable for BCD data output unit.
• 26-core cable with connector on one end
Link cable for controller
communication unit
SL-F
Controller
communication unit
GP-XCOM
Extension cable for
sensor head
• GP-XCCJ7
GP-X
SPECIFICATIONS
Sensor heads
Non-threaded type
Type
Threaded type
For 0.8 mm 0.031 in sensing For 1 mm 0.039 in sensing For 2 mm 0.079 in sensing For 2 mm 0.079 in sensing For 5 mm 0.197 in sensing For 10 mm 0.394 in sensing
Item
Model No.
GP-X3SE
GP-X5SE
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
Sensing range (Note 1)
0 to 0.8 mm 0 to 0.031 in 0 to 1 mm 0 to 0.039 in 0 to 2 mm 0 to 0.079 in 0 to 2 mm 0 to 0.079 in 0 to 5 mm 0 to 0.197 in 0 to 10 mm 0 to 0.394 in
Standard sensing object
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 6060t 1 mm 2.3622.362t 0.039 in
0.07 % F.S./C or less
Temperature characteristics (Note 2)
Environmental resistance
Pollution degree
3 (Industrial environment)
Protection
IP67 (IEC), IP67g (JEM)
10 to55 C 14 to131 F, Storage: 20 to70 C 4 to158 F
Ambient temperature
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability
250 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for five times each
Material
Shock resistance
Enclosure
Brass (Nickel plated)
Stainless steel (SUS303)
Cable protector
Sensing Part
PP
ABS
Accessories
ABS
PA
Extension up to total 10 m 32.808 ft is possible with the optional cable
Cable extension
Weight (Note 4)
PAR
High frequency coaxial cable with connector, 3 m 9.843 ft long (Note 3)
Cable
40 g approx.
40 g approx.
40 g approx.
50 g approx.
45 g approx.
80 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
Notes: 1) The sensing range is specified for the standard sensing object.
2) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
3) For the flexible cable type, please contact our office.
4) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
8
GP-X
SPECIFICATIONS
Controllers
Type
Item
NPN output
Set model No.
PNP output
GP-XC
GP-XC-P
24 V DC 10 % Ripple P-P 10 % or less
Supply voltage
Current consumption
150 mA or less
GP-XC3SE / GP-XC5SE: 0.04 % F.S. (64 times average processing)
GP-XC8S / GP-XC10M / GP-XC12ML / GP-XC22KL: 0.02 % F.S. (64 times average processing)
Resolution (Note 1)
Sampling frequency
40 kHz (25 !s)
Within 0.3 % F.S.
Linearity (Note 1)
Temperature characteristics (Note 2)
0.07 % F.S./C or less
Output voltage: 5 to 5 V (Note 3), Output impedance: 100 Ω approx.
Analog voltage output
Response time
75 !s (maximum speed)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Applied voltage: 30 V DC or less (between comparative output and V)
• Residual voltage: 1.6 V or less (at 100 mA sink current)
• Residual voltage: 1.6 V or less (at 100 mA source current)
0.4 V or less (at 16 mA sink current)
0.4 V or less (at 16 mA source current)
Comparative outputs
(HI, GO, LO)
Utilization category
DC-12 or DC-13
Output number
HI / GO / LO 3 value output
HI : ON when measured value the upper limit value
GO: ON when upper limit value j measured value j lower limit value
LO : ON when lower limit value measured value
Output operation
Short-circuit protection
Incorporated
Photocoupler input
Photocoupler input
• Input current: 9 mA or less
• Input current: 9 mA or less
• Operating voltage: ON voltage 17 V or more (between 24 V and input)
• Operating voltage: ON voltage 17 V or more (between 0 V and input)
OFF voltage 4 V or less (between 24 V and input)
OFF voltage 4 V or less (between 0 V and input)
• Input impedance: 5 kΩ approx.
• Input impedance: 5 kΩ approx.
External input
Serial I/O
RS-232C
Zero-set setting method
Push button setting / External input setting
Indicators
MODE
Orange LED (lights up when in mode status)
HI
Orange LED (lights up when the upper limit value is exceeded)
GO
Green LED (lights up when within the upper and lower limit values)
LO
Orange LED (lights up when less than the lower limit value)
TIMING
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit values)
Lower line digital display part
5 digit green LED (display of numerical values within the upper and lower limit values)
Environmental resistance
Upper line digital display part
Pollution degree
3 (Industrial environment)
Ambient temperature
0 to50 C 32 to 122 F (No dew condensation), Storage: 0 to50 C 32 to 122 F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
EMC
EN 61000-6-2, EN 61000-6-4
Vibration resistance
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Shock resistance
Material
Enclosure: Polycarbonate
Weight
120 g approx.
Accessory
ATA4811 (controller mounting frame): 1 set
Notes: 1) This value is obtained at a constant 25 C 77 F.
2) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
3) Adjusted to a 0 to 5 V factory setting.
BCD output unit
Model No.
Current consumption
Output
5 digits BCD,
Polarity indication,
VALID
(
Hold input
Material
Weight
Accessory
)
Controller communication unit
GP-XBCD
Model No.
20 mA or less
N-channel MOSFET open drain
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and GND)
• Residual voltage: 1 V or less (at 50 mA sink current)
Current consumption
Non-voltage contact or NPN open-collector transistor input
• Low: 0 to 1 V • High: Open
Enclosure: ABS
30 g approx.
Mounting bracket [Stainless steel (SUS304)]: 1 pc.
Note: Connects to the control device with GP-XBCC3 cable with connector
on one end for BCD output unit (3 m 9.843 ft cable length, optional).
9
GP-XCOM
5 mA or less
Material
Enclosure: ABS
Weight
20 g approx.
Accessory
Mounting bracket [Stainless steel (SUS304)]: 1 pc.
Note: Each GP-XCOM is connected using a link cable for controller communication units (SL-F, optional).
When GP-XCOM is used, controllers cannot communicate if their
software versions are not compatible (Ver. 1.06 or earlier version with
Ver 2.00 or later version).
Check the software version and use the correct combination.
GP-X
I/O CIRCUIT AND WIRING DIAGRAMS
NPN output
type controller
PNP output
type controller
I/O circuit diagram
18
Tr1
ZD2
ZD1
Tr2
ZD3
Tr3
ZD4
Tr6
Tr5
ZD6
I/O circuit diagram
Terminal No.
D1
1
2
V
18
Comparative Load
output LO
Comparative 100mA max.
output GO
4
Load
Tr1
Load
Comparative output HI 100mA max.
Load
3
Alarm output 100mA max.
Load
24 V DC
10 %
5
Tr4
ZD5
6
7
Terminal No.
D1
Strobe output
ZD1
Tr2
1
ZD2
Tr3
100mA max.
100 mA max.
Interference
prevention output
Used for interference
prevention function.
2
ZD3
T r4
3
5
ZD4
Tr5
6
ZD5
Output COM.
0V
17
47 Ω
Tr6
9
Analog voltage output (5 to 5 V) (Note)
8
For analog output GND
ZD6
24 V
10
Main circuit
11
47 Ω
Zero-set input
24 V
5 kΩ
Memory selection input 1
5 kΩ
24 V
5 kΩ
12
Comparative output GO 100mA max.
Comparative output HI 100mA max.
Load
Load
24V DC
10%
Load
Alarm output 100mA max.
Load
Strobe output
Used for interference
prevention function.
0V
9
Analog voltage output (5 to 5 V) (Note)
8
For analog output GND
13
Input COM. (24 V)
m1
m1
m1
m2
m1
Main circuit
5 kΩ
47 Ω
100mA max.
Comparative output LO 100mA max.
7
17
Output COM.
Interference prevention output Load
4
47 Ω
V
10
Memory selection input 2
5 kΩ
11
Zero-set input
Memory selection input 1
24 V
5 kΩ
14
Timing input
5 kΩ
24 V
5 kΩ
24 V
5 kΩ
5 kΩ
15
Reset input
Interference prevention input
Used for interference
16
m1
prevention function.
5 kΩ
m2
m1
m1
5 kΩ
Internal circuit
15
Timing input
Reset input
16
Interference
prevention input
Internal circuit
Users’ circuit
Symbols D1: Reverse supply polarity protection diode
ZD1 to ZD6: Surge absorption zener diode
Tr1 to Tr6: NPN output transistor
14
Memory selection input 2
m1
Input COM.
13
(0 V)
Note: Devices connected to the analog voltage output must have an input
impedance set at 1 MΩ or more.
12
Users’ circuit
Note: Devices connected to the analog voltage output must have an input
impedance set at 1 MΩ or more.
Symbols D1: Reverse supply polarity protection diode
ZD1 to ZD6: Surge absorption zener diode
Tr1 to Tr6: PNP output transistor
m1
m1
Non-voltage contact or NPN open-collector transistor
Non-voltage contact or PNP open-collector transistor
or
or
• Zero-set input, reset input, memory selection input
Low (0 to 4 V) : Effective
High (V or open) : Ineffective
• Zero-set input, reset input, memory selection input
Low (0 V or open) : Ineffective
High (17 V to24 V) : Effective
m2
m2
NPN open-collector transistor
PNP open-collector transistor
• Timing input
Low (0 to 4 V): Effective
High (V or open): Ineffective
• Timing input
Low (0 V or open): Ineffective
High (17 to 24 V): Effective
Memory selection input
Memory No.
0
1
2
3
Used for interference
prevention function.
Memory selection 1 Memory selection 2
High
High
Low
High
High
Low
Low
Low
Memory selection input
Memory No.
0
1
2
3
Memory selection 1 Memory selection 2
Low
Low
High
Low
Low
High
High
High
10
GP-X
I/O CIRCUIT AND WIRING DIAGRAMS
Controller
Terminal arrangement
123456789
0ABCDEFGH
Connector for RS-232C
communication
Connector for
sensor head connection
Terminal No.
1
2
3
4
5
6
7
8
9
Terminal No.
Description
Comparative output LO
Comparative output GO
Comparative output HI
Output COM.
Alarm output
Strobe output
Interference prevention output
For analog output GND
Analog output
0
A
B
C
D
E
F
G
H
Description
Zero-set input
Memory selection input 1
Memory selection input 2
Input COM.
Timing input
Reset input
Interference prevention input
0V
V
BCD output unit
Connector pin position and cable color
Cable
Connector
pin No. Sheath color ID mark
Orange
Orange
Gray
Gray
White
White
Yellow
Yellow
Pink
Pink
Orange
Orange
Gray
Gray
White
White
Yellow
Yellow
Pink
Pink
Orange
Red: 1
Black: 1
Red: 1
Black: 1
Red: 1
Black: 1
Red: 1
Black: 1
Red: 1
Black: 1
Red: 2
Black: 2
Red: 2
Black: 2
Red: 2
Black: 2
Red: 2
Black: 2
Red: 2
Black: 2
Red: 3
L
Orange
Black: 3
M
Gray
Red: 3
N
O
Signal
Gray
Black: 3
White
Red: 3
White
Black: 3
Note: The shield wire is connected externally at 0 V.
11
Description
1
2 Measurement value
4 to the 100 digit
8
1
2 Measurement value
4 to the 101 digit
8
1
2 Measurement value Measurement value
BCD output
4 to the 102 digit
8
1
2 Measurement value
4 to the 103 digit
8
1
2 Measurement value
4 to the 104 digit
8
Polarity signal output
High (OFF): , Low (ON):
Low (ON) when the
VALID
output
VALID
data output is enabled
This input is to maintain the external
data output. The data output is
HOLD Hold input
maintained during low (ON).
GND Ground
GND Ground
Not used
Not connected
A0
B0
C0
D0
A1
B1
C1
D1
A2
B2
C2
D2
A3
B3
C3
D3
A4
B4
C4
D4
POLE
25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
1
2
3
4
5
6
7
8
9
0
A
B
C
D
E
F
G
H
I
J
K
Connector for controller connection
Connector for BCD output
GP-X
PRECAUTIONS FOR PROPER USE
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
Mounting with nut
B
• The sensor head and the controller are adjusted in order to
conform to the default specification linearity.
• In the event of replacing sensor heads, input the sensor head’s
characteristic code and conduct 3-point correction (calibration).
• Should you use an extension cable, turn the sensor head cable
length selection switch located on the back of the controller to
‘3 m + 7 m 9.843 ft + 22.966 ft’. Then reintroduce the power
supply and conduct 3-point correction (calibration).
Attached toothed
lock washer
B
Mounting plate
Attached toothed
lock washer
Attached toothed
lock washer
B
Mounting plate
Mounting plate
Model No.
B (mm in)
Tightening torque
GP-X10M
GP-X12ML
GP-X22KL
7 0.276 or more
9.8 N m or less
14 0.551 or more
20 N m or less
20 0.787 or more (Note 1)
20 N m or less
Notes: 1) Without nut. If a nut is installed, the dimension
will be 23.5 mm or more.
2) Mount such that the nuts do not protrude from
the threaded portion.
Conditions in use for CE conformity
• This sensor is a CE conformity product complying with EMC
Directive. The harmonized standard with regard to immunity that
applies to this product is EN 61000-6-2 and the following
conditions must be met to conform to that standard.
Distance from surrounding metal
Conditions
• The controller should be connected less than 10 m 32.808 ft from
the power supply.
• The signal line to connect with the controller should be less than
30 m 98.425 ft.
• A ferrite clamp must be mounted within 10 mm 0.394 in from
connector fitted onto the GP-XBCC3 cable with connector on one
end for BCD output units.
The EN 50082-2 that previously applied to the products for conforming to
EMC Directive was replaced by EN 61000-6-2 starting April 1st. 2002.
• As metal around the sensor may affect the sensing performance,
pay attention to the following points.
• Since the analog output may change if the sensor head is
completely embedded in metal, keep the minimum distance
specified in the table below.
Sensor head
C
D
Metal
Linearity in case of disc-shaped or cylindrical objects
• In case the sensing object is disc-shaped or cylindrical, the
linearity varies with the sensing object size.
In the event the sensing object is larger than the sizes indicated in
the table below, the linearity specification (within 0.3 % F.S.) is
satisfied by performing zero-adjustment and span adjustment
when in contact using the scaling function.
Sensor head
Disc diameter " (mm in) Cylinder diameter " (mm in)
GP-X3SE
GP-X5SE
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
6 0.236
8 0.315
12 0.472
12 0.472
25 0.984
30 1.181
16 0.630
16 0.630
50 1.969
50 1.969
55 2.165
165 6.496
GP-X3SE
GP-X5SE
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
F
" (mm in)
" mm
in
t : 1 mm 0.039 in
(
(
"18 "0.709
"14 "0.551
"50 "1.969
"50 "1.969
3 0.118
14 0.551
20 0.787
t
"10 "0.394
Mutual interference
E
Iron cylinder
D (mm in)
• If several sensor heads are mounted close together, some
specifications may not be satisfied. Therefore, proceed with the
interference prevention function enabled.
The interference prevention function eliminates interference
among sensors by alternating sensor oscillations. Contact our
office for details about time charts etc.
If not using the interference prevention function, leave a distance
more than the values given below.
Iron disc
C (mm in)
Sensor head
GP-X3SE
GP-X5SE
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
E (mm in)
15 0.591
F (mm in)
9 0.354
30 1.181
40 1.575
40 1.575
170 6.693
200 7.874
11 0.433
15 0.591
15 0.591
50 1.969
200 7.874
?
# : 135 mm 5.315 in
Mounting sensor head
• The tightening torque should be under the value given below.
Mounting with set screw
• Make sure to use an M3 or smaller set screw having a cup-point.
Set screw (M3 or less)
Sensing range
• The sensing range is specified for the standard sensing object
[stainless steel (SUS304) / iron [Cold rolled carbon steel (SPCC)],
6060t 1 mm 2.3622.362t 0.039 in]. For sensing metals
other than the standard sensing objects, use the correction
coefficient stated below as a guideline. Verify with the actual
sensor before using.
Correction coefficient
(Cup-point)
A
Sensor head
Model No.
A (mm in)
Tightening torque
GP-X3SE
GP-X5SE
GP-X8S
4 to 16 0.157 to 0.630
0.10 N m or less
Metal
0.44 N m or less
Stainless steel (SUS304), Iron
0.58 N m or less
Aluminum
5 to 16 0.197 to 0.630
GP-X3SE
GP-X5SE
GP-X8S
GP-X10M
GP-X12ML
GP-X22KL
1
0.5 approx.
12
GP-X
PRECAUTIONS FOR PROPER USE
Connection of sensor head and controller
Mounting controller
• Make sure that the power supply is off while connecting the
sensor head to the controller.
• Use the attached controller mounting frame (ATA4811) and mount
the controller onto the panel by fastening the frame’s screws.
Connection
• Hold the sensor head’s connector by the outer ring and insert it
into the connector provided on the controller for sensor head
connection. Insert till you hear a click sound.
Controller mounting
frame (ATA4811)
Controller
• Refer to the ‘DIMENSIONS’ (P.14) for the panel cut-out dimension.
• The mountable panel thickness is 1 to 5 mm 0.039 to 0.197 in.
However, if using a controller communication unit or BCD output unit,
make the panel thickness between 1 and 2.5 mm 0.039 and 0.098 in.
Connector for
sensor head connection
Wiring
Connector
outer ring
Removing
• When removing, hold the connector outer ring and pull it straight
out.
•
Cable extension for sensor head
• When using a sensor head extension cable, turn the sensor head
cable length selection switch side to the controller’s sensor head
connector to ‘3 m 7 m 9.843 ft22.966 ft’ with the power
supply is off. After switching, reintroduce the power supply.
Sensor head cable length
selection switch
Connector for sensor
head connection
•
•
•
•
•
•
•
UP side : Standard (3 m 9.843 ft) extension (7 m 22.966 ft)
DOWN side : Standard (3 m 9.843 ft) (factory shipment setting)
•
• The coaxial connector for the extension cable is connected to the
0 V power supply. If installing to a metal plate or similar, insulate
the connector from the surrounding metal.
•
•
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor head or the controller.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of the sensor head or the
controller, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause malfunction
due to induction.
Make sure to use an isolation transformer for the power supply. It
an auto-transformer (single winding transformer) is used, this
product or the power supply may get damaged.
In case a surge is generated in the used power supply, connect a
surge absorber to the supply and absorb the surge.
The analog voltage output does not incorporate a short-circuit
protection circuit. Do not directly connect a power supply or a
capacitive load.
Make sure that stress by forcible bend or pulling is not applied
directly to the sensor cable joint.
If using separate power supplies for multiple controllers, use the
same V or 0 V supply for all.
Others
• Do not use during the initial transient time (2 sec. approx.) after
the power supply is switched on.
• This sensor is suitable for indoor use only.
• Avoid dust, dirt, and steam.
• Take care that the product does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
DIMENSIONS (Unit: mm in)
GP-X3SE
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
GP-X5SE
Sensor head
Sensor head
"2.5 "0.098 high frequency
coaxial cable, 3 m 9.843 ft long
17
0.669
Coaxial connector for
controller connection
17
0.669
(6.2)
(0.244)
"2.5 "0.098 high frequency
coaxial cable, 3 m 9.843 ft long
Coaxial connector for
controller connection
("6.4)
("0.252)
("6.4)
("0.252)
"3.8 "0.150
13
(17)
(0.669)
(25.7)
(1.012)
"5.4 "0.213
(17)
(0.669)
(25.7)
(1.012)
GP-X
DIMENSIONS (Unit: mm in)
GP-X8S
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
GP-X10M
Sensor head
Sensor head
"2.5 "0.098 high frequency
coaxial cable, 3 m 9.843 ft long
"2.5 "0.098 high frequency
coaxial cable, 3 m 9.843 ft long
14
0.551
Coaxial connector for
controller connection
(6.2)
(0.244)
17
0.669
17
0.669
("6.4)
("0.252)
("6.4)
("0.252)
(17)
(0.669)
(25.7)
(1.012)
"8 "0.315
GP-X12ML
Sensor head
17
0.669
7
0.276
(17)
M101
(0.669)
(25.7)
Nut
(1.012)
Toothed lock washer (internal tooth)
3
0.118
"18 "0.709
GP-X22KL
"2.5 "0.098 high frequency
coaxial cable, 3 m 9.843 ft long
(6.2)
(0.244)
21
0.827
Sensor head
35 1.378
20 0.787
Coaxial connector for
controller connection
"2.5 "0.098 high frequency
(6.2) (0.244) coaxial cable, 3 m 9.843 ft long
17
0.669
Coaxial connector for
controller connection
("6.4)
("0.252)
"10.1
"0.398
(17)
(0.669)
(25.7)
Nut
(1.012)
Toothed lock washer (internal tooth)
M121 0.039
3.5
0.138
"21 "0.827
Controller mating coaxial connector
(6.2)
(0.244)
"22 "0.866
3.5
0.138
(25.7)
(1.012)
("6.4)
M121 0.039
("0.252)
Nut
"21 "0.827
Toothed lock
Diameter of
washer
(internal tooth) toothed lock
washer
(
)
Controller
Comparative output operation indicators (Orange / Green / Orange)
5-digit, dual numerical display (Orange / Green)
Timing indicator (Green)
10
0.394
73
2.874
Terminal block
(16.7)
(0.657)
GP-X series
SHIFT key
44.5
1.752
48
1.890
Zero-set key
ENTER key
MODE indicator (Orange)
MODE key
Connector for RS-232C
UP key
Sensor head cable length selection switch
DOWN key
Coaxial connector for sensor head connection
Panel cut-out dimensions
450.6
0
0.024
1.772
0
450.6
0
1.7720.024
0
450.6
0
1.7720.024
0
Minimum 90 3.543
When mounted in series
A(48n2.5)0.6
0
A(1.890n0.098)0.024
0
A
Note: The panel thickness should be 1 to 5 mm 0.039 to 0.197 in.
450.6
0
1.7720.024
0
Minimum 90 3.543
Minimum 100 0.098
Note: The panel thickness should be 1 to 2.5 mm 0.039 to 0.098 in.
14
DIMENSIONS (Unit: mm in)
GP-XBCD
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
BCD output unit (Optional)
Assembly dimensions with controller
Connector for controller connection
Mounting
frame
40
1.575
Controller
Mounting bracket
BCD output unit
Connector for BCD output
(68)
(2.677)
20
(8.5)
0.787 (0.335)
55
2.165
Panel
thickness
1 to 2.5
0.039 to 0.098
(74.6)
(2.937)
Connector for BCD output
(68)
(2.677)
(27.8)
(1.094)
Cable with connector for BCD output unit
GP-XCOM
Controller communication unit (optional)
Assembly dimensions with controller
Connector for communication
Connector for controller connection
Mounting
frame
Controller
Mounting bracket
Communication unit
40
1.575
Terminator switch
Terminator switch
(68)
(2.677)
55
2.165
20
(8.5)
0.787 (0.335)
Communication cable
Panel
thickness
1 to 2.5
0.039 to 0.098
Connector for
communication
(74.6)
(2.937)
(68)
(2.677)
All information is subject to change without prior notice.
SUNX Limited
2431-1 Ushiyama-cho, Kasugai-shi, Aichi,
486-0901, Japan
Phone: +81-(0)568-33-7211
FAX: +81-(0)568-33-2631
Overseas Sales Dept.
http://www.sunx.co.jp/
Phone: +81-(0)568-33-7861
FAX: +81-(0)568-33-8591
Printed on 100% recycled paper
PRINTED IN JAPAN
No. CE-GPX-7 May, 2003