TESTING
LOW-PROFILE SURFACE-MOUNT RELAY
TQ-SMD RELAYS
FEATURES
14 .551 9 .354 5.6 .220
mm inch
• Low-profile: 6 mm .236 inch in height comforming to EIA standards (Tape height: max. 6.5 mm .256 inch ) • Tape and reel package is available as standard packing style • Surge withstand between contacts and coil: 2,500 V • Breakdown voltage between contacts and coil: 1,500 V • High capacity: 2 A • High sensitivity: 2 Form C; 140 mW power consumption (Single side stable type)
SPECIFICATIONS
Contact
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity f1 Single side stable Nominal operating power 1 coil latching 2 coil latching Mechanical (at 180 cpm) 2 A 30 V DC resistive Electrical 1 A 30 V DC (at 20 cpm) resistive 0.5 A 125 V AC resistive 2 Form C 75 mΩ Gold-clad silver alloy 2 A 30 V DC, 0.5 A 125 V AC 60 W, 62.5 VA 220 V DC, 125 V AC 2A 10 µA 10 mV DC 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 70 mW (1.5 to 12 V DC) 100 mW (24 V DC) 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 108 105 Vibration resistance 2×105 105 Destructive Conditions for oper- Ambient ation, transport and temperature storage*8 (Not freezing and condensing Humidity at low temperature) Unit weight Initial breakdown voltage
Characteristics
Initial insulation resistance*1 Between open contacts Between contact sets Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 V (FCC Part 68) 2,500 V (Bellcore) Max. 50°C Max. 4 ms (Approx. 2 ms) [Max. 4 ms (Approx. 2 ms)] Max. 4 ms (Approx. 1 ms) [Max. 4 ms (Approx. 2 ms)] Min. 750 m/s2 {75 G} Min. 1,000 m/s2 {100 G} 200 m/s2 {20G}, 10 to 55 Hz at double amplitude of 3.3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +85°C*3 –40°F to +185°F 5 to 85% R.H. Approx. 2 g .071 oz
Between contact and coil Between open contacts Initial surge (10×160 µs) voltage Between contacts and coil (2×10 µs) Temperature rise*2 (at 20°C) Operate time [Set time]*3 (at 20°C) Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7
Expected life (min. operations)
Note:
f1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 4. Conditions for operation, transport and storage mentioned in Cautions for use (Page 178).
140
TQ-SMD
ORDERING INFORMATION
Ex. TQ Contact arrangement 2: 2 Form C 2 SA
–
L
–
3V
–
Z Packing style Nil: Tube packing Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side)
Surface-mount availability SA: Standard surface-mount SA: terminal type SL : High connection reliability SA: surface-mount terminal type SS: Space saving surfaceSA: mount terminal type
Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching
Coil voltage (DC) 1.5, 3, 4.5, 5, 6, 9, 12, 24, 48* V
*48 V coil type: Single side stable only Notes: 1. Tape and reel (picked from 1/2/3/4/5-pin side) is also available by request. Part No. suffix “-X” is needed when ordering. (ex.) TQ2SA-3V-X 2. Tape and reel packing symbol “-Z” or “-X” are not marked on the relay.
Surface-mount terminal variation
Variation Terminal style Ambient environment Normal environments Drastic temperature fluctuations (indoor) (outdoor)
SA type (Standard surface-mount terminal type)
4.9 .193 7.62 .300 11.5±0.5 .453±.020
0.25 .010
Recommended
—
SL type (Highly connection reliability surface-mount terminal type)
4.9 .193 7.62 .300 11.5±0.5 .453±.020
0.25 .010
Recommended
Recommended
SS type (Space saving surface-mount terminal type)
4.9 .193 7.62 .300 9.3±0.5 ±.020
0.25 .010
Recommended
Recommended
TYPES
1. Single side stable
Part No. TQ2Sr-1.5 V TQ2Sr-3 V TQ2Sr-4.5 V TQ2Sr-5 V TQ2Sr-6 V TQ2Sr-9 V TQ2Sr-12 V TQ2Sr-24 V TQ2Sr-48 V Nominal voltage, V DC 1.5 3 4.5 5 6 9 12 24 48 Pick-up voltage, V DC (max.) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 36 Drop-out voltage, V DC (min.) 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4 4.8 Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3 6.3 Coil resistance, Ω (±10%) 16 64.3 145 178 257 579 1,028 2,880 7,680 Nominal operating power, mW 140 140 140 140 140 140 140 200 300 Max. allowable voltage, V DC 2.2 4.5 6.7 7.5 9 13.5 18 36 57.6
2. 1 coil latching
Part No. TQ2Sr-L-1.5 V TQ2Sr-L-3 V TQ2Sr-L-4.5 V TQ2Sr-L-5 V TQ2Sr-L-6 V TQ2Sr-L-9 V TQ2Sr-L-12 V TQ2Sr-L-24 V Nominal voltage, V DC 1.5 3 4.5 5 6 9 12 24 Set voltage, V DC (max.) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Reset voltage, V DC (max.) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Nominal operating current, mA (±10%) 46.9 23.3 15.6 14 11.7 7.8 5.8 4.2 Coil resistance, Ω (±10%) 32 128.6 289.3 357 514 1,157 2,057 5,760 Nominal operating power, mW 70 70 70 70 70 70 70 100 Max. allowable voltage, V DC 2.2 4.5 6.7 7.5 9 13.5 18 36
141
TQ-SMD
3. 2 coil latching
Part No. TQ2Sr-L2-1.5 V TQ2Sr-L2-3 V TQ2Sr-L2-4.5 V TQ2Sr-L2-5 V TQ2Sr-L2-6 V TQ2Sr-L2-9 V TQ2Sr-L2-12 V TQ2Sr-L2-24 V Nominal voltage, V DC 1.5 3 4.5 5 6 9 12 24 Set voltage, V DC (max.) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Reset voltage, V DC (max.) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3 Coil resistance, Ω (±10%) 16 64.3 145 178 257 579 1,028 2,880 Nominal operating power, mW 140 140 140 140 140 140 140 200 Max. allowable voltage, V DC 2.2 4.5 6.7 7.5 9 13.5 18 36
r: For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case; 1,000 pcs.; Tape and reel: 500 pcs./reel 3. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
DIMENSIONS
SA type
14 .551 5.6 .220 2.54 .100 0.5 .020 0.2 .008 4.9 .193 7.62 .300 11.5±0.5 .453±.020 9 .354 0.25 .010
mm inch
Recommendable mounting pad (Top view) SA type
1 .039 2.94 .116 2.54 .100 2 .079 9.56 .376
Schematic (Top view)
•Single side stable (Deenergized condition)
− +
1 2 3 4 5 10 9 8 7 6
Direction indication* *Orientation stripe located on top of relay.
SL type
14 .551 Max. 7.5 .295 2.54 .100 0.5 .020 4.9 .193 7.62 .300 11.5±0.5 .453±.020 2.94 .116 14 .551 Max. 7.5 .295 2.54 .100 0.5 .020 4.9 .193 7.62 .300 9.3±0.5 ±.020 9 .354 0.25 .010 9.56 .376 9 .354 0.25 .010 0.3 .012
For glue-pad
14 .551
•1-coil latching (Reset condition)
+ −
1 2 3 4 5 10 9 8 7 6
SL type
1 .039 2.54 .100
SS type
Direction indication* *Orientation stripe located on top of relay.
•2-coil latching (Reset condition)
SS type
1 .039 1.84 .072 8.46 .333 2.54 .100
10 9
8
7
6
+ +
1 2 3 4
− −
5
General tolerance: ±0.3 ±.012
Direction indication* *Orientation stripe located on top of relay.
Tolerance: ±0.1 ±.004
REFERENCE DATA
1. Maximum switching capacity 2. Life curve 3. Mechanical life (mounting by IRS method)
Tested sample: TQ2SA-12V, 10 pcs.
3.0 Switching current, A 2.0 DC resistive load No. of operations, × 104 100 50 30 20 10 125V AC resistive load 30V DC resistive load Ratio against the rated voltage, %V 100 90 80 70 60 50 40 30 20 10 0 20 30 50 100 200 300 Contact voltage, V 0 1.0 2.0 Switching current, A 0 IRS 1 Min. Drop-out voltage Max. Pick-up voltage Max. Min.
1.0 AC resistive load
0.5 0.4 0.3 0.2
10 100 1,000 10,000 4 No. of operations, ×10
142
TQ-SMD
4.-(1) Electrical life (2 A 30 V DC resistive load)
Tested sample: TQ2SA-12V, 6 pcs. Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
100 Ratio against the rated voltage, %V 90 80 70 60 50 40 30 20 10 0 IRS 1 2 Max. Min. 3 4 5 6 7 8 9 10 No. of operations, ×104 Drop-out voltage Pick-up voltage Max. Min.
4.-(2) Electrical life (0.5 A 125 V AC resistive load)
Change of contact resistance (mounting by IRS method)
100 Ratio against the rated voltage, %V Contact resistance, mΩ 90 80 70 60 50 40 30 20 10 0 IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 Min. Max.
Tested sample: TQ2SA-12V, 6 pcs Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
100 90 80 70 60 50 40 30 20 10 0 IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 Drop-out voltage Max. Min. Pick-up voltage Max. Min.
5. Coil temperature rise
Change of contact resistance (mounting by IRS method)
100 90 Contact resistance, mΩ 80 70 60 50 40 30 20 10 0 IRS 1 2 3 4 5 6 7 8
4
6. Operate/release time
Tested sample: TQ2SA-12V, 6 pcs.
Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F
70 Temperature rise, °C 60 50 40 30 20 10 0 100 110 120 130 140 150 Coil applied voltage, %V 2A 0A Coil voltage DC 12V type DC 48V type 2A
5 Operate and release time, ms Operate time Release time 4 Max. Min.
0A
3
Max. Min.
2 Max. Min.
1 0
9 10
70
80
No. of operations, ×10
90 100 110 120 Coil applied voltage, %V
7. Distribution of pick-up and drop out voltage
Tested sample: TQ2SA-12V, 50 pcs.
8. Distribution of set and reset voltage
Tested sample: TQ2SA-L-12V, 30 pcs.
30
9. Ambient temperature characteristics
Tested sample: TQ2SA-12V, 5 pcs.
Rate of change, %
,,
,PPPPP P@@@@@ @,,,,, PP P P @@ @ @ ,, , ,
30
Pick-up voltage
Set voltage Reset voltage
40 Pick-up voltage x
,,
25 Quantity 20
10. Distribution of contact resistance
Tested sample: TQ2SA-5V, 30 pcs. (30 × 4 contacts)
50
10 9 8 7 6
,, ,
12345
Isolation, dB
(TOP VIEW)
Quantity
100
30
Terminal Nos. 2-3, 8-9
Insertion loass, dB
40
,,,,,,,, ,,,
,, , , PP P P @@ @ @ ,, , , PP P P @@ @ @ ,, , , PP P P @@ @ @ ,, , , PP P P @@ @ @ ,, , , ,PPPPP ,,,,,, P@@@@@ @,,,,, ,PPPPP P@@@@@ @,,,,, ,PPPPP P@@@@@ @,,,,, ,PPPPP P@@@@@ @,,,,,
Drop-out voltage 20 10 0 Terminal Nos. 3-4, 7-8 20 10 0 20
Quantity
20
10 5
,,,, ,, , ,,,,,
15
,,,,, ,, , , ,,,,
0 10 100 Frequency, MHz
–40 –20
0
Drop-out voltage 20 40 60 80 Ambient temperature, °C –20
–40
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
11.-(1) High-frequency characteristics
Isolation characteristics
11.-(2) High-frequency characteristics
Insertion loss characteristics
– +
,,,,,,,, ,,,,,,
,
1.0 0.8 0.6 0.4 0.2
50
30 40 50 Contact resistance, mΩ
1,000
10
100 Frequency, MHz
1,000
143
TQ-SMD
12.-(1) Malfunctional shock (single side stable)
Tested sample: TQ2SA-12V, 6 pcs
Z' Y Y' ZX X' Y 1000m/s 2 Deenergized condition Energized condition Z' 1000m/s 2
12.-(2) Malfunctional shock (latching)
Tested sample: TQ2SA-L2-12V, 6 pcs.
Z' Y Y' ZX X' Y 1000m/s 2 Reset condition Set condition Z' 1000m/s 2
X 1000m/s2
X 1000m/s2
1000m/s 2 Z 1000m/s 2 Y'
1000m/s 2 X'
1000m/s 2 Z 1000m/s 2 Y'
1000m/s 2 X'
13.-(1) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 5 pcs.
Rate of change, % 10 Pick-up voltage 0 –10 ON ON ON
13.-(2) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 6 pcs.
Rate of change, % 10 Pick-up voltage 0 ON –10 ON 10 0 –10 OFF 0 1 23 45 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch Drop-out voltage OFF OFF ON
13.-(3) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 6 pcs.
Rate of change, % 10 Pick-up voltage 0 –10
ON ON ON ON
Rate of change, %
Rate of change, %
10 Drop-out voltage 0 –10 0
OFF OFF
Rate of change, %
10 0 –10 0
OFF Drop-out voltage OFF OFF OFF 1 23 45 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
OFF 1 23 45 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
14. Pulse dialing test
Tested sample: TQ2SA-12V, 6 pcs. (35 mA 48 V DC wire spring relay load) Change of pick-up and drop-out voltage (mounting by IRS method)
Ratio against the rated voltage, %V 100 90 Contact resistance, mΩ 80 70 60 50 40 30 20 10 0 IRS 10 20 30 40 No. of operations, ×104 50 Drop-out voltage Pick-up voltage Max. Min.
Change of contact resistance (mounting by IRS method)
100 90 80 70 60 50 40 30 20 10 0 IRS 10 20 30 40 No. of operations, ×104 50 Max. Min.
Circuit
+
0.08 µF 48 V DC
458 Ω 0.08 µF TQ-SMD 3 relay 2
–
458 Ω Wire spring relay
Max. Min.
For Cautions for Use, see Page 178 and 179.
144 9/1/2000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog