Partly Order Discontinued as of August 31, 2011
TX
TESTING
New pin layout (LT type)
added. Best seller with
broad lineup and AC 2000 V
breakdown voltage.
Compliance with RoHS Directive
FEATURES
1. 2,000 V breakdown voltage between
contact and coil
The body block construction of the coil
that is sealed at formation offers a high
breakdown voltage of 2,000 V between
contact and coil, and 1,000 V between
open contacts.
2. Outstanding surge resistance.
Surge breakdown voltage between
open contacts:
1,500 V 10×160µ sec. (FCC part 68)
Surge breakdown voltage between
contact and coil:
2,500 V 2×10µ sec. (Bellcore)
3. Nominal operating power: High
sensitivity of 140mW
By using the highly efficient polar
magnetic circuit “seesaw balance
mechanism”, a nominal operating
power of 140 mW (minimum operating
power of 79 mW) has been achieved.
4. High contact capacity: 2 A 30 V DC
5. Compact size
15.0(L) × 7.4(W) × 8.2(H) .591(L) ×
.291(W) × .323(H)
6. The use of gold-clad twin crossbar
contacts ensures high contact
reliability.
*We also offer a range of products
with AgPd contacts suitable for use
in low level load analog circuits
(Max. 10V DC 10 mA).
*SX relays designed for low level
loads are also available.
7. Outstanding vibration and shock
resistance.
Functional shock resistance: 750 m/s2
Destructive shock resistance:
1,000 m/s2
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm .130 inch)
TX RELAYS
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm .197 inch)
8. Sealed construction allows
automatic washing.
9. A range of surface-mount types is
also available
SA: Low-profile surface-mount
terminal type
SL: High connection reliability surfacemount terminal type
SS: Space saving surface-mount
terminal type
TYPICAL APPLICATIONS
1. Communications (xDSL,
Transmission)
2. Measurement
3. Security
4. Home appliances, and audio/visual
equipment
5. Automotive equipment
6. Medical equipment
ORDERING INFORMATION
TX 2
Contact arrangement
2: 2 Form C
Surface-mount availability
Nil: Standard PC board terminal type or self-clinching terminal type
SA: SA type
SL: SL type
SS: SS type
Operating function
Nil: Single side stable
L: 1 coil latching
L2: 2 coil latching
LT: 2 coil latching
Terminal shape
Nil: Standard PC board terminal or surface-mount terminal
H: Self-clinching terminal
Nominal coil voltage (DC)*
1.5, 3, 4.5, 5, 6, 9, 12, 24, 48V
Contact material
Nil: Standard contact (Ag+Au clad)
1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable)
Packing style
Nil: Tube packing
X: Tape and reel (picked from 1/3/4/5-pin side)
Z: Tape and reel packing (picked from the 8/9/10/12-pin side)
Notes: 1. *48 V coil type: Single side stable only
2. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX
TYPES
1. Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
2 Form C
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2-1.5V
TX2-3V
TX2-4.5V
TX2-5V
TX2-6V
TX2-9V
TX2-12V
TX2-24V
TX2-48V
1 coil latching
Part No.
TX2-L-1.5V
TX2-L-3V
TX2-L-4.5V
TX2-L-5V
TX2-L-6V
TX2-L-9V
TX2-L-12V
TX2-L-24V
—
2 coil latching (L2)
Part No.
TX2-L2-1.5V
TX2-L2-3V
TX2-L2-4.5V
TX2-L2-5V
TX2-L2-6V
TX2-L2-9V
TX2-L2-12V
TX2-L2-24V
—
2 coil latching (LT)
Part No.
TX2-LT-1.5V
TX2-LT-3V
TX2-LT-4.5V
TX2-LT-5V
TX2-LT-6V
TX2-LT-9V
TX2-LT-12V
TX2-LT-24V
—
2 coil latching (L2)
Part No.
TX2-L2-H-1.5V
TX2-L2-H-3V
TX2-L2-H-4.5V
TX2-L2-H-5V
TX2-L2-H-6V
TX2-L2-H-9V
TX2-L2-H-12V
TX2-L2-H-24V
—
2 coil latching (LT)
Part No.
TX2-LT-H-1.5V
TX2-LT-H-3V
TX2-LT-H-4.5V
TX2-LT-H-5V
TX2-LT-H-6V
TX2-LT-H-9V
TX2-LT-H-12V
TX2-LT-H-24V
—
2 coil latching (L2)
Part No.
TX2S-L2-1.5V
TX2S-L2-3V
TX2S-L2-4.5V
TX2S-L2-5V
TX2S-L2-6V
TX2S-L2-9V
TX2S-L2-12V
TX2S-L2-24V
—
2 coil latching (LT)
Part No.
TX2S-LT-1.5V
TX2S-LT-3V
TX2S-LT-4.5V
TX2S-LT-5V
TX2S-LT-6V
TX2S-LT-9V
TX2S-LT-12V
TX2S-LT-24V
—
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2. self-clinching terminal
Contact
arrangement
Nominal coil
voltage
2 Fom C
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2-H-1.5V
TX2-H-3V
TX2-H-4.5V
TX2-H-5V
TX2-H-6V
TX2-H-9V
TX2-H-12V
TX2-H-24V
TX2-H-48V
1 coil latching
Part No.
TX2-L-H-1.5V
TX2-L-H-3V
TX2-L-H-4.5V
TX2-L-H-5V
TX2-L-H-6V
TX2-L-H-9V
TX2-L-H-12V
TX2-L-H-24V
—
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
3. Surface-mount terminal
1) Tube packing
Contact
arrangement
Nominal coil
voltage
2c
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2S-1.5V
TX2S-3V
TX2S-4.5V
TX2S-5V
TX2S-6V
TX2S-9V
TX2S-12V
TX2S-24V
TX2S-48V
1 coil latching
Part No.
TX2S-L-1.5V
TX2S-L-3V
TX2S-L-4.5V
TX2S-L-5V
TX2S-L-6V
TX2S-L-9V
TX2S-L-12V
TX2S-L-24V
—
: For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
2 Form C
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2S-1.5V-Z
TX2S-3V-Z
TX2S-4.5V-Z
TX2S-5V-Z
TX2S-6V-Z
TX2S-9V-Z
TX2S-12V-Z
TX2S-24V-Z
TX2S-48V-Z
1 coil latching
Part No.
TX2S-L-1.5V-Z
TX2S-L-3V-Z
TX2S-L-4.5V-Z
TX2S-L-5V-Z
TX2S-L-6V-Z
TX2S-L-9V-Z
TX2S-L-12V-Z
TX2S-L-24V-Z
—
2 coil latching (L2)
Part No.
TX2S-L2-1.5V-Z
TX2S-L2-3V-Z
TX2S-L2-4.5V-Z
TX2S-L2-5V-Z
TX2S-L2-6V-Z
TX2S-L2-9V-Z
TX2S-L2-12V-Z
TX2S-L2-24V-Z
—
2 coil latching (LT)
Part No.
TX2S-LT-1.5V-Z
TX2S-LT-3V-Z
TX2S-LT-4.5V-Z
TX2S-LT-5V-Z
TX2S-LT-6V-Z
TX2S-LT-9V-Z
TX2S-LT-12V-Z
TX2S-LT-24V-Z
—
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please add “-1” to the end of the part number for AgPd contacts (low level load).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX
RATING
1. Coil data
1) Single side stable
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
140mW
150%V of
nominal voltage
1.5V DC
93.8mA
16Ω
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
46.7mA
31mA
28.1mA
23.3mA
15.5mA
11.7mA
5.8mA
64.3Ω
145Ω
178Ω
257Ω
579Ω
1,028Ω
4,114Ω
5.6mA
8,533Ω
270mW
120%V of
nominal voltage
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
100mW
150%V of
nominal voltage
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
48V DC
2) 1 coil latching
1.5V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
66.7mA
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
33.3mA
22.2mA
20mA
16.7mA
11.1mA
8.3mA
4.2mA
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
22.5Ω
90Ω
202.5Ω
250Ω
360Ω
810Ω
1,440Ω
5,760Ω
3) 2 coil latching (L2, LT)
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
Set coil
Reset coil
133.9mA
133.9mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
16.7mA
8.3mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
16.7mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
Set coil
11.2Ω
Reset coil
11.2Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
720Ω
2,880Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
720Ω
2,880Ω
Nominal operating
power
Set coil
Reset coil
200mW
200mW
*Pulse drive (JIS C 5442-1986)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Max. applied voltage
(at 20°C 68°F
150%V of
nominal voltage
Partly Order Discontinued as of August 31, 2011
TX
2. Specifications
Characteristics
Item
Arrangement
Initial contact resistance, max.
Contact
Specifications
2 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
220V DC
Standard contact: 2 A, AgPd contact: 1 A
10µA 10mV DC
140 mW (1.5 to 24 V DC), 270 mW (48 V DC)
100 mW (1.5 to 24 V DC)
200 mW (1.5 to 24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil)
[–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g .071 oz
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
Nominal operating
1 coil latching
power
2 coil latching
Rating
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage (Initial)
Electrical
characteristics
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Shock resistance
Mechanical
characteristics
Expected life
Conditions for operation, transport and storage*2
Conditions
Max. operating speed (at rated load)
Unit weight
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
REFERENCE DATA
1. Maximum switching capacity
2. Life curve
3. Mechanical life
Ratio against the rated voltage, %V
Tested sample: TX2-5V, 10 pcs.
Operating speed: 180 cpm
2.0
100
No. of operations ×104
Switching current, A
3.0
DC resistive load
1.0
0.5
0.4
0.3
50
30V DC
resistive load
30
20
10
0.2
100
90
80
Pick-up voltage
70
Max.
60
Min.
50
40
30
Drop-out voltage
20
Max.
Min.
10
0
20 30
0
50
100
200 300
Contact voltage, V
0
1.0
2.0
Switching current, A
10
100
1,000
No. of operations, ×104
10,000
4. Electrical life (2A 30V DC resistive load)
5-(1). Coil temperature rise
Tested sample: TX2-5V, 6 pcs.
Operating speed: 20 cpm
Tested sample: TX2-5V, 6 pcs.
Point measured: Inside the coil
Ambient temperature: 25°C 77°F, 85°C 185°F
Change of contact resistance
100
90
90
80
Pick-up voltage
70
Max.
60
Min.
50
40
Drop-out voltage
30
Max.
20
80
70
60
50
40
Max.
30
Min.
+25°C +77°F
+85°C +185°F
60
50
40
30
2A
2A
20
0A
0A
20
Min.
10
0
70
Temperature rise, °C
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
1
2
3
4 5 6 7 8 9
No. of operations, ×104
10
10
10
0
1
2
3
4 5 6 7 8 9
No. of operations, ×104
10
0
100 110
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
120 130 140 150
Coil applied voltage, %
Partly Order Discontinued as of August 31, 2011
TX
5-(2). Coil temperature rise
6-(1). Operate and release time (with diode)
6-(2). Operate and release time (without diode)
Tested sample: TX2-48V, 6 pcs.
Point measured: Inside the coil
Ambient temperature: 25°C 77°F, 70°C 158°F
Tested sample: TX2-5V, 10 pcs.
Tested sample: TX2-5V, 10 pcs.
60
50
2A
40
2A
0A
30
0A
20
5
5
Operate time
Release time
4
Max.
3
Min.
2
Max.
Min.
Operate and release time, ms
+25°C +77°F
+70°C +158°F
Operate and release time, ms
1
10
100 110
0
120 130 140 150
Coil applied voltage, %
7. Ambient temperature characteristics
Rate of change, %
Tested sample: TX2-5V, 5 pcs.
–40 –20
0
4
Max.
Min.
3
2
Max.
Min.
70
80
0
90
100 110 120
Coil applied voltage, %V
70
80
90
100 110 120
Coil applied voltage, %V
8-(1). High frequency characteristics
(Isolation)
8-(2). High frequency characteristics
(Insertion loss)
Tested sample: TX2-12V, 2 pcs.
Tested sample: TX2-12V, 2 pcs.
40
20
Drop-out
voltage x
x
Pick-up voltage
20 40 60 80
Ambient temperature, °C
Isolation, dB
0
Operate time
Release time
1
Insertion loss, dB
Temperature rise, °C
70
100
50
–20
1.0
0.8
0.6
0.4
0.2
–40
10
100
Frequency, MHz
1,000
10
100
Frequency, MHz
1,000
10-(2). Influence of adjacent mounting
Tested sample: TX2-12V, 6 pcs.
Tested sample: TX2-12V, 6 pcs.
Y
1000m/s 2
Deenergized condition
Energized condition
X
1000m/s2
Z
1000m/s2
1000m/s2
X'
1000m/s 2
Z'
1000m/s 2
Y'
5
ON
ON
Pick-up voltage
0
–5
ON
Rate of change, %
Z XX'
Rate of change, %
Z'
Y
Y'
Rate of change, %
10-(1). Influence of adjacent mounting
Tested sample: TX2-5V, 6 pcs.
Rate of change, %
9 Malfunctional shock (single side stable)
OFF OFF
5
Drop-out voltage
0
–5
OFF
0
2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance
ON
5
Pick-up voltage
0
ON
–5
ON
OFF
5
Drop-out voltage
0
OFF
–5
OFF
0
, mm inch
2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance
, mm inch
11. Pulse dialing test
Circuit
+
458 Ω
0.08
µF
48V DC
–
0.08
µF
458 Ω
Wire spring relay
4
TX
3
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
Change of contact resistance
100
100
90
90
80
Pick-up voltage
70
Max.
Min.
60
50
40
Drop-out voltage
30
20
Max.
Min.
80
70
60
50
Max.
40
Min.
30
20
10
10
0
Contact resistance, mΩ
Tested sample: TX2-5V, 6 pcs.
(35 mA 48 V DC wire spring relay load)
10
20
30
40
No. of operation, ×104
50
0
Note: Data of surface-mount type are the same as those of PC board terminal type.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
10
20
30
40
4
No. of operations, ×10
50
Partly Order Discontinued as of August 31, 2011
TX
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://panasonic-electric-works.net/ac
1. Standard PC board terminal and Self clinching terminal
Single side stable and 1 coil latching type
CAD Data
External dimensions
2 coil latching type (L2, LT)
External dimensions
Standard PC board terminal
15.00
.591
Standard PC board terminal
7.40
.291
7.40
.291
15.00
.591
0.65
.026
0.65
.026 8.20
.323
0.50
.020
1.15
.045
5.08
.200
0.50
.020
1.15
.045
0.25
5.08 .010
.200
3.50
.138
2.54
.100
Self clinching terminal
5.08
.200
2.54
.100
15.00
.591
7.40
.291
0.50
.020
1.15
.045
0.25
5.08 .010
.200
3.50
.138
2.54
.100
(1.15)
2.54 (.045) 3.50
.100
.138
5.08
.200
General tolerance: ±0.3 ±.012
PC board pattern
(Bottom view)
Schematic (Bottom view)
Single side stable
10.16
.400
2.54
.100
+
5.08
.200
–
8-1.0 dia.
8-.039 dia.
1
12
–
+
10 9 8
Direction indication
Tolerance: ±0.1 ±.004
1
2.54
.100
5.08
.200
12
10 9 8
10-1.0 dia.
10-.039 dia.
Direction indication
(Deenergized condition)
Schematic (Bottom view)
2 coil latching (L2)
12.7
.500
3 4 5
Tolerance: ±0.1 ±.004
(Reset condition)
0.25
5.08 .010
.200
General tolerance: ±0.3 ±.012
PC board pattern
(Bottom view)
1 coil latching
3 4 5
7.40
.291
0.65
.026 8.20
.323
0.65 8.20
.026 .323
5.08
.200
0.25
5.08 .010
.200
3.50
.138
Self clinching terminal
15.00
.591
0.50
.020
1.15
.045
8.20
.323
1
3 4 5 6
+
–
+
–
12
10 9 8 7
2 coil latching (LT)
+
1
– 12
3 4 5 6
10 9 8 7
Direction indication
Direction indication
(Reset condition)
(Reset condition)
2. Surface-mount terminal
CAD Data
External dimensions (General tolerance: ±0.3 ±.012)
Single side stable and
2 coil latching type (L2, LT)
1 coil latching type
Type
15
.591
15
.591
7.4
.291
8.2
8.4
.323 .331
SA type
0.5
.020
0.65
.026
5.08
.200
2.54
.100
8.2
8.4
.323 .331
0.5
.020
0.65
.026
5.08
.200
7.4
.291
15
.591
2.54
.100
0.65
.026
0.5
.020
5.08
.200
15
.591
0.25
.010
0.65
.026
0.5
.020
5.08
.200
2.54
.100
15
.591
7.4
.291
0.65
.026
0.5
.020
5.08
.200
1
3.16 .039
.124
0.65
.026
0.5
.020
5.08
.200
2.54
.100
5.08
1 .200
3.16 .039
.124
2.54
.100
–
+
12
1
10 9 8
3
4 5
Direction indication
(Deenergized condition)
1 coil latching
+
–
12
2 coil latching (L2)
10 9 8
12
10 9 8
+
+
1
3
4 5
Direction indication
(Reset condition)
1
7
0.25
.010
5.08
.200
–
–
3
4 5
6
Direction indication
(Reset condition)
+
2.54
.100
7.24
.285
2.54
.100
1
2.16
.085 .039
6.24
.246
2 coil latching (LT)
–
7.24
.285
5.08
1 .200
3.16 .039
.124
Schematic (Top view)
Single side stable
2.54
.100
7.24
.285
1
2.16 .039
.085
5.08
.200
7.4±0.5
.291±.020
5.08
.200
0.25
.010
7.4
.291
0.25
.010
2.54
.100
2 coil latching type (L2, LT)
7.24
.285
8.2 Max.10
.323 .394
5.08
.200
7.4±0.5
.291±.020
2.54
.100
5.08
.200
9.4±0.5
.370±.020
5.08
.200
0.25
.010
7.4
.291
8.2 Max.10
.323 .394
SS type
1
3.16 .039
.124
8.2 Max.10
.323 .394
5.08
.200
9.4±0.5
.370±.020
2.54
.100
5.08
.200
9.4±0.5
.370±.020
15
.591
8.2 Max.10
.323 .394
SL type
Single side stable and
1 coil latching type
7.4
.291
0.25
.010
5.08
.200
9.4±0.5
.370±.020
Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004)
12
10 9 8 7
1
3
4 5 6
–
+
Direction indication
(Reset condition)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
5.08
.200
2.54
.100
6.24
.246
+
–
Partly Order Discontinued as of August 31, 2011
TX
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1) stripe
Stopper (gray)
Stopper (green)
2) Tape and reel packing (surface-mount
terminal type)
(1) Tape dimensions
(i) SA type
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
A
C
B
mm inch
1.5 +0.1
0 dia.
Relay polarity bar .059 +.004
dia. 2.0
0
(Z type)
.079
1.75
.069
4.0
.157
0.4
.016
C
A
B
11.5
.453
D
16.0 10.0 .394
.630
Relays
15.5
.610
24.0 ±0.3
±0.2
.945 ±.012 9.2±.008
.362
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
Tape coming out direction
(ii) SL type
mm inch
1.5 +0.1
0 dia.
Relay polarity bar .059 +.004
dia. 2.0
0
(Z type)
.079
1.75
.069
4.0
.157
0.4
.016
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
11.5
.453
15.5
.610
16.0
.630
Relays
10.0
.394
Tape coming out direction
24.0 ±0.3
.945 ±.012
±0.2
10.8±.008
.425
(iii) SS type
mm inch
1.5
Relay polarity bar .059
(Z type)
+0.1
0
+.004
0
dia.
dia. 2.0
.079
4.0
.157
1.75
.069
0.4
.016
11.5
.453
15.5
.610
16.0
.630
Relays
Tape coming out direction
8.0 24.0 ±0.3
±.012
.315 .945 10.8±0.2
.425±.008
(2) Dimensions of plastic reel
mm inch
2.0
.079
13 dia.
.512 dia.
21 dia.
.827 dia.
380 dia.
14.961 dia.
80 dia.
3.150 dia.