TX-D
Several part
part numbers
numbers will
will be
be discontinued
discontinued September
September 30,
30, 2013.
2013.
Several
High breakdown voltage type
is available (1.5 kV between
open contacts)
3.
Several part numbers will be discontinued
September 30, 2013.
FEATURES
1.
Lineup now includes high
breakdown voltage type that
achieves breakdown voltage
between open contacts of
1,500 V AC.
Surge breakdown voltage between
open contacts:
1,500 V 10 160 sec. (FCC part 68)
Surge breakdown voltage between
contact and coil:
6,000 V 1.2 50 sec. (EN60950)
2. Approved to the supplementary
insulation class in the EN standards
(EN60950).
The insulation distance between the
contact and coil meet the
supplementary insulation class of the
EN60950 standards as required for
equipment connected to the telephone
lines in Europe.
Satisfies the following conditions:
• Clearances: 2.0 mm .079 inch or
more
• Creepage distance: 2.5 mm .098 inch
or more
ds_61022_en_txd: 150113D
3,000 V breakdown voltage
between contact and coil. (Surge
breakdown voltage 6,000 V type)
The body block construction of the coil
that is sealed formation offers a high
breakdown voltage of 3,000 V between
contact and coil.
4. Nominal operating power:
High sensitivity of 200 mW
By using the highly efficient polar
magnetic circuit “seesaw balance
mechanism”, a nominal operating
power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved
with gold-clad crossbar twin
contacts and the use of gas
expelling materials during
formation.
*We also offer TX-series relays with
AgPd contacts, suitable for use in low
level load analog circuits.
7. Outstanding vibration and shock
resistance.
Functional shock resistance: 750 m/s2
Destructive shock resistance:
1,000 m/s2
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm .197 inch)
8. Sealed construction allows
automatic washing.
9. A range of surface-mount types is
also available.
SA: Low-profile surface-mount
terminal type
SS: Space saving surface-mount
terminal type
10. M.B.B. type available (Surge
breakdown voltage 2,500 V type
only)
TESTING
TX-D RELAYS
TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security
1
TX-D
Several part numbers will be discontinued September 30, 2013.
ORDERING INFORMATION
TXD 2
Contact arrangement
2: 2 Form C
Surface-mount availability
Nil: Standard PC board terminal
SA: SA type
SS: SS type
Operating function
Nil: Single side stable
L: 1 coil latching
Type of operation
Nil: Standard type
2M: M.B.B. type (Surge breakdown voltage 2,500 V and Single side stable type only)
Terminal shape
Nil: Standard PC board terminal or surface-mount terminal
Nominal coil voltage (DC)
1.5, 3, 4.5, 5, 6, 9, 12, 24V
Contact material/Surge breakdown voltage (between contact and coil)/Breakdown (between open contacts)
Nil: Standard contact (Ag+Au clad), 2,500 V/1,000 V
1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 2,500 V/1,000 V
3: Standard contact (Ag+Au clad), 6,000 V/1,500 V
4: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 6,000 V/1,500 V
(Discontinued Sept. 30, 2013)
6: Standard contact (Ag+Au clad ), 6,000 V/1,000 V
7: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 6,000 V/1,000 V
Packing style
Nil: Tube packing
X: Tape and reel (picked from 1/3/4/5-pin side)
Z: Tape and reel packing (Picked from the 8/9/10/12-pin side)
Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
Several part numbers will be discontinued September 30, 2013.
TYPES
1. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2-1.5V
TXD2-L-1.5V
TXD2-3V
TXD2-L-3V
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2-4.5V
TXD2-L-4.5V
5V DC
TXD2-5V
TXD2-L-5V
6V DC
TXD2-6V
TXD2-L-6V
9V DC
TXD2-9V
TXD2-L-9V
12V DC
TXD2-12V
TXD2-L-12V
24V DC
TXD2-24V
TXD2-L-24V
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2S-1.5V
TXD2S-L-1.5V
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2S-3V
TXD2S-L-3V
TXD2S-4.5V
TXD2S-L-4.5V
5V DC
TXD2S-5V
TXD2S-L-5V
6V DC
TXD2S-6V
TXD2S-L-6V
9V DC
TXD2S-9V
TXD2S-L-9V
12V DC
TXD2S-12V
TXD2S-L-12V
24V DC
TXD2S-24V
TXD2S-L-24V
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2
ds_61022_en_txd: 150113D
TX-D
Several part numbers will be discontinued September 30, 2013.
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2S-1.5V-Z
TXD2S-L-1.5V-Z
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2S-3V-Z
TXD2S-L-3V-Z
TXD2S-4.5V-Z
TXD2S-L-4.5V-Z
5V DC
TXD2S-5V-Z
TXD2S-L-5V-Z
6V DC
TXD2S-6V-Z
TXD2S-L-6V-Z
9V DC
TXD2S-9V-Z
TXD2S-L-9V-Z
12V DC
TXD2S-12V-Z
TXD2S-L-12V-Z
24V DC
TXD2S-24V-Z
TXD2S-L-24V-Z
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-1” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-1-Z)
2. M.B.B type/Surge breakdown voltage (between contact and coil) 2,500 V/
Breakdown voltage (between open contacts) 1,000 V
1) Standard PC board terminal
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
2 Form C
Single side stable
Part No.
TXD2-2M-1.5V
TXD2-2M-3V
TXD2-2M-4.5V
5V DC
TXD2-2M-5V
6V DC
TXD2-2M-6V
9V DC
TXD2-2M-9V
12V DC
TXD2-2M-12V
24V DC
TXD2-2M-24V
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
2) Surface-mount terminal
(1) Tube packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
2 Form C
Single side stable
Part No.
TXD2S-2M-1.5V
TXD2S-2M-3V
TXD2S-2M-4.5V
5V DC
TXD2S-2M-5V
6V DC
TXD2S-2M-6V
9V DC
TXD2S-2M-9V
12V DC
TXD2S-2M-12V
24V DC
TXD2S-2M-24V
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
(2) Tape and reel packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
2 Form C
Single side stable
Part No.
TXD2S-2M-1.5V-Z
TXD2S-2M-3V-Z
TXD2S-2M-4.5V-Z
5V DC
TXD2S-2M-5V-Z
6V DC
TXD2S-2M-6V-Z
9V DC
TXD2S-2M-9V-Z
12V DC
TXD2S-2M-12V-Z
24V DC
TXD2S-2M-24V-Z
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Types designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.
However, please contact us if you need parts for use in low level load. (Ex. TXD2SA-2M-1.5V-1-Z)
2. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
ds_61022_en_txd: 150113D
3
TX-D
Several part numbers will be discontinued September 30, 2013.
3. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/
Breakdown voltage (between open contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2-1.5V-6
TXD2-L-1.5V-6
3V DC
TXD2-3V-6
TXD2-L-3V-6
TXD2-4.5V-6
TXD2-L-4.5V-6
5V DC
TXD2-5V-6
TXD2-L-5V-6
6V DC
TXD2-6V-6
TXD2-L-6V-6
9V DC
TXD2-9V-6
TXD2-L-9V-6
12V DC
TXD2-12V-6
TXD2-L-12V-6
24V DC
TXD2-24V-6
TXD2-L-24V-6
4.5V DC
2 Form C
1 coil latching
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2S-1.5V-6
TXD2S-L-1.5V-6
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2S-3V-6
TXD2S-L-3V-6
TXD2S-4.5V-6
TXD2S-L-4.5V-6
5V DC
TXD2S-5V-6
TXD2S-L-5V-6
6V DC
TXD2S-6V-6
TXD2S-L-6V-6
9V DC
TXD2S-9V-6
TXD2S-L-9V-6
12V DC
TXD2S-12V-6
TXD2S-L-12V-6
24V DC
TXD2S-24V-6
TXD2S-L-24V-6
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2S-1.5V-6-Z
TXD2S-L-1.5V-6-Z
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2S-3V-6-Z
TXD2S-L-3V-6-Z
TXD2S-4.5V-6-Z
TXD2S-L-4.5V-6-Z
5V DC
TXD2S-5V-6-Z
TXD2S-L-5V-6-Z
6V DC
TXD2S-6V-6-Z
TXD2S-L-6V-6-Z
9V DC
TXD2S-9V-6-Z
TXD2S-L-9V-6-Z
12V DC
TXD2S-12V-6-Z
TXD2S-L-12V-6-Z
24V DC
TXD2S-24V-6-Z
TXD2S-L-24V-6-Z
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-7” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-7-Z)
4
ds_61022_en_txd: 150113D
TX-D
Several part numbers will be discontinued September 30, 2013.
4.
Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/
Breakdown voltage (between open contacts) 1,500 V (High breakdown voltage type)
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2-1.5V-3
TXD2-L-1.5V-3
TXD2-3V-3
TXD2-L-3V-3
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2-4.5V-3
TXD2-L-4.5V-3
5V DC
TXD2-5V-3
TXD2-L-5V-3
6V DC
TXD2-6V-3
TXD2-L-6V-3
9V DC
TXD2-9V-3
TXD2-L-9V-3
12V DC
TXD2-12V-3
TXD2-L-12V-3
24V DC
TXD2-24V-3
TXD2-L-24V-3
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2S-1.5V-3
TXD2S-L-1.5V-3
3V DC
4.5V DC
2 Form C
1 coil latching
TXD2S-3V-3
TXD2S-L-3V-3
TXD2S-4.5V-3
TXD2S-L-4.5V-3
5V DC
TXD2S-5V-3
TXD2S-L-5V-3
6V DC
TXD2S-6V-3
TXD2S-L-6V-3
9V DC
TXD2S-9V-3
TXD2S-L-9V-3
12V DC
TXD2S-12V-3
TXD2S-L-12V-3
24V DC
TXD2S-24V-3
TXD2S-L-24V-3
: For each surface-mount terminal identification, input the following letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
Single side stable
Part No.
Part No.
1.5V DC
TXD2SA-1.5V-3-Z
TXD2SA-L-1.5V-3-Z
3V DC
TXD2SA-3V-3-Z
TXD2SA-L-3V-3-Z
TXD2SA-4.5V-3-Z
TXD2SA-L-4.5V-3-Z
5V DC
TXD2SA-5V-3-Z
TXD2SA-L-5V-3-Z
6V DC
TXD2SA-6V-3-Z
TXD2SA-L-6V-3-Z
9V DC
TXD2SA-9V-3-Z
TXD2SA-L-9V-3-Z
12V DC
TXD2SA-12V-3-Z
TXD2SA-L-12V-3-Z
24V DC
TXD2SA-24V-3-Z
TXD2SA-L-24V-3-Z
4.5V DC
2 Form C
1 coil latching
*Only for SA type.
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-4” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-4-Z)
ds_61022_en_txd: 150113D
5
TX-D
Several part numbers will be discontinued September 30, 2013.
RATING
1. Coil data
[Standard (B.B.M.) type]
1) Single side stable
Nominal operating current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
1.5V DC
132.7mA
187.5mA
11
8
3V DC
66.7mA
93.5mA
45
32
Nominal coil
voltage
Pick-up
Drop-out
voltage
voltage
(at 20C 68F) (at 20C 68F)
4.5V DC
75%V or less
of nominal
voltage*
(Initial)
5V DC
6V DC
10%V or more
of nominal
voltage*
(Initial)
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
44.4mA
62.5mA
101
72
40.0mA
56.2mA
125
89
33.3mA
46.5mA
180
129
22.2mA
31.1mA
405
289
12V DC
16.7mA
23.3mA
720
514
24V DC
9.6mA
12.9mA
2,504
1,858
9V DC
Nominal operating power
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Max. applied
voltage
(at 20C 68F)
200mW
280mW
120%V of
nominal
voltage
230mW
310mW
2) 1 coil latching
Nominal operating current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
1.5V DC
100.0mA
153.1mA
15
10
3V DC
50.0mA
76.9mA
60
39
Nominal coil
voltage
Set voltage
Reset voltage
(at 20C 68F) (at 20C 68F)
4.5V DC
5V DC
6V DC
75%V or less
of nominal
voltage*
(Initial)
75%V or less
of nominal
voltage*
(Initial)
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
33.3mA
51.1mA
135
88
30.0mA
46.3mA
166
109
25.0mA
38.5mA
240
156
16.7mA
25.6mA
540
352
12V DC
12.5mA
19.2mA
960
626
24V DC
7.1mA
10.4mA
3,388
2,304
9V DC
Nominal operating power
Surge
breakdown
voltage:
2,500V/
6,000 V
Surge
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Max. applied
voltage
(at 20C 68F)
150mW
230mW
120%V of
nominal
voltage
170mW
250mW
[M.B.B. type]
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
1.5V DC
166.7mA
9
3V DC
83.3mA
36
4.5V DC
5V DC
6V DC
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
55.6mA
81
50.0mA
100
41.7mA
144
324
9V DC
27.8mA
12V DC
20.8mA
576
24V DC
11.3mA
2,133
Nominal operating
power
Max. applied voltage
(at 20C 68F)
250mW
120%V of
nominal voltage
270mW
*Pulse drive (JIS C 5442-1986)
*Only for surge breakdown voltage of 2,500 V.
6
ds_61022_en_txd: 150113D
TX-D
Several part numbers will be discontinued September 30, 2013.
2. Specifications
Characteristics
Item
Specifications
Arrangement
Contact
2 Form C
Contact resistance (Initial)
2 Form D (M.B.B.type)*1
Max. 100 m (By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Contact material
Standard contact: 2 A 30 V DC,
AgPd contact: 1 A 30 V DC (resistive load)
1 A 30 V DC (resistive load)
Max. switching power
Standard contact: 60 W (DC),
AgPd contact: 30 W (DC) (resistive load)
30 W (DC) (resistive load)
Max. switching voltage
220 V DC
110 V DC
Max. switching current
Standard contact: 2 A, AgPd contact: 1 A
Nominal switching capacity
Min. switching capacity (Reference value)*2
Single side stable
Surge breakdown voltage
2,500 V and
6,000 V types:
200mW (1.5 to 12 V DC), 230mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
280mW (1.5 to 12 V DC), 310mW (24 V DC)
250mW (1.5 to 12 V DC), 270mW (24 V DC)
1 coil latching
Surge breakdown voltage
2,500 V and
6,000 V types:
150mW (1.5 to 12 V DC), 170mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
230mW (1.5 to 12 V DC), 250mW (24 V DC)
—
Rating
Nominal operating
power
Insulation resistance (Initial)
Min. 1,000M (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Between open contacts
Surge breakdown voltage
2,500 V and
6,000 V types:
1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
1,500 Vrms for 1min. (Detection current: 10mA)
500 Vrms for 1min. (Detection current: 10mA)
Between contact and coil
Surge breakdown voltage 2,500 V type:
2,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage
6,000 V and
6,000 V (High breakdown voltage) types:
3,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Breakdown
voltage (Initial)
Electrical
characteristics
Between contact sets
Surge breakdown
voltage (Initial)
1,000 Vrms for 1min. (Detection current: 10mA)
Between open contacts
1,500 V (10160s) (FCC Part 68)
—
Between contacts and
coil*1
Surge breakdown voltage 2,500 V type:
2,500 V, 2 10s (Telcordia)
Surge breakdown voltage 6,000 V and 6,000 V
(High breakdown voltage) types:
6,000 V, 1.2 50s
2,500 V, 2 10s (Telcordia)
Max. 50C 122F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 2A [1A: M.B.B.].)
Temperature rise (at 20C 68F)
Mechanical
characteristics
Operate time [Set time] (at 20C 68F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Conditions
Min. 750 m/s2
(Half-wave pulse of sine wave: 6 ms;
detection time: 10s.)
Min. 500 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10s.)
Shock
resistance
Functional
Destructive
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
Destructive
Mechanical
Expected life
1A
10A10mV DC
Electrical
Conditions for operation, transport and
storage*3
Max. operating speed (at rated load)
Unit weight
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (at 180 cpm)
Min. 107 (at 180 cpm)
Min. 10 (2 A 30 V DC resistive),
Min. 5105 (1 A 30 V DC resistive) (at 20 cpm)
Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
5
Ambient temperature: –40C to +85C –40F to +185F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g .071 oz
*1
*2
M.B.B. type models are only available in 2,500 V surge breakdown voltage type.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load. (AgPd contact type is available for low level load switching.)
*3The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
ds_61022_en_txd: 150113D
7
TX-D
Several part numbers will be discontinued September 30, 2013.
REFERENCE DATA
1. Maximum switching capacity
2. Life curve
3. Mechanical life
Ratio against the rated voltage, %V
Tested sample: TXD2-5V, 10 pcs.
Operating speed: 180 cpm
No. of operations x104
Switching current, A
3.0
2.0
DC resistive load
1.0
0.5
0.4
0.3
100
50
30
30V DC
resistive load
20
10
0.2
100
90
Pick-up voltage
80
Max.
70
60
Min.
50
Drop-out voltage
40
Max.
30
Min.
20
10
0
20 30
0
50
100
200 300
Contact voltage, V
0
1.0
2.0
Switching current, A
0
10
100
1000
No. of operations, ×104
10000
4. Electrical life (2 A 30 V DC resistive load)
5-(1). Coil temperature rise
Tested sample: TXD2-5V, 6 pcs.
Operating speed: 20 cpm
Tested sample: TXD2-5V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 25C 77F, 70C 158F
Change of contact resistance
100
70
90
90
60
Pick-up voltage
80
Max.
70
Min.
60
50
Drop-out voltage
40
Max.
30
20
Min.
Max.
50
40
Min.
30
50
40
2A
30
2A
20
0A
0A
10
4
6
8
No. of operations, ×104
70
+25°C +77°F
+70°C +158°F
60
50
40
2A
2A
30
0
10
0A
0A
20
0
0
2
4
6
8
No. of operations, ×104
6-(2). Operate/release time characteristics
(without diode)
Tested sample: TXD2-5V, 10 pcs.
Tested sample: TXD2-5V, 10 pcs.
5
5
Operate time
Release time
4
Max.
Min.
3
Max.
Min.
2
0
110
120
Coil applied voltage, %V
0
70
80
90
100
110
Max.
Min.
3
2
0
120
Max.
Min.
70
80
90
100 110 120
Coil applied voltage, %V
8. High-frequency characteristics
(Isolation)
9. High-frequency characteristics
(Insertion loss)
Tested sample: TXD2-12V, 2 pcs.
Tested sample: TXD2-12V, 2 pcs.
40
x
20
Drop-out voltage
x
Pick-up voltage
20 40 60 80
Ambient temperature, °C
-20
Insertion loss, dB
-40 -20
4
Coil applied voltage, %V
Isolation, dB
Variation ratio, %
Tested sample: TXD2-5V, 5 pcs.
Operate time
Release time
1
1
7. Ambient temperature characteristics
110
120
Coil applied voltage, %V
6-(1). Operate/release time characteristics
(with diode)
10
100
100
10
Operate and release time, ms
2
Operate and release time, ms
0
Tested sample: TXD2-24V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 25C 77F, 70C 158F
Temperature rise, °C
60
+25°C +77°F
+70°C +158°F
10
5-(2). Coil temperature rise
0
70
20
10
0
80
Temperature rise, °C
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
100
50
1.0
0.8
0.6
0.4
0.2
-40
0
8
10
100
Frequency, MHz
1,000
0
10
100
Frequency, MHz
1,000
ds_61022_en_txd: 150113D
TX-D
Several part numbers will be discontinued September 30, 2013.
11-(2). Influence of adjacent mounting
Tested sample: TXD2-12V, 6 pcs.
Tested sample: TXD2-12V, 6 pcs.
Deenergized
condition
Energized condition
X'
Y
1000m/s 2
X
1000m/s 2
Z
1000m/s 2
1000m/s 2
Z'
1000m/s 2
X'
1000m/s 2
Y'
5
ON
ON
Pick-up voltage
0
-5
ON
Rate of change, %
X
Rate of change, %
Z
Z'
Y
Y'
Rate of change, %
11-(1). Influence of adjacent mounting
Tested sample: TXD2-5V, 6 pcs
Rate of change, %
10. Malfunctional shock (single side stable)
OFF OFF
5
Drop-out voltage
0
OFF
-5
0
2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance
ON
5
0
Pick-up voltage
ON
-5
ON
OFF
5
0
Drop-out voltage
OFF
-5
OFF
0
, mm inch
2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance
, mm inch
12. Actual load test (35 mA 48 V DC wire spring
relay load)
458 Ω
+
0.08
F
48 V DC
–
0.08
F
4
TXD
3
458 Ω
Wire spring relay
Change of contact resistance
100
100
90
90
80
Pick-up voltage
Max.
Min.
70
60
50
Drop-out voltage
40
30
Max.
20
Min.
Contact resistance, mΩ
Circuit
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
Tested sample: TXD2-5V, 6 pcs.
70
60
50
40
Max.
Min.
30
20
10
0
80
10
0
10
20
30
40
No. of operation, ×104
0
50
0
10
20
30
40
No. of operation, ×104
50
13-(1). Distribution of M.B.B. time
Tested sample: TXD2-2M-5V, 50 pcs.
Terminal No. 3-4-5: ON
Terminal No. 3-4-5: OFF
60
60
300.5 μs
x:
σn-1: 55.3 μs
Min.: 165 μs
Max.: 415 μs
50
40
30
298.8 μs
x:
σn-1: 51.8 μs
Min.: 205 μs
Max.: 432 μs
50
40
30
22
20
16
12
7
350
400
450 μs max.
250
300
350
400 μs min.
150
200
250
300
350
400
450 μs max.
~
300
200
~
250
150
~
200
100
~
150
1
0
~
400 μs min.
~
350
~
300
~
250
~
200
~
150
~
8
1
100
~
0
13
10
6
2
~
10
12
~
20
13-(2). Distribution of M.B.B. time
14.
Tested sample: TXD2-2M-5V, 50 pcs.
Terminal No. 8-9-10: ON
60
293.4 μs
x:
σn-1: 60.4 μs
Min.: 155 μs
Max.: 445 μs
50
Surge breakdown voltage test
Tested sample: TXD2-3V-6, 30 pcs.
Terminal No. 8-9-10: OFF
60
281.4 μs
x:
σn-1: 58.3 μs
Min.: 120 μs
Max.: 421 μs
50
14
12
40
40
10
30
30
8
18
4
10
300
350
400
450 μs max.
1
1
0
100
150
200
250
300
350
400 μs min.
150
200
250
300
350
400
450 μs max.
~
250
4
~
200
~
150
~
400 μs min.
~
350
~
300
~
250
~
200
~
150
6
~
3
100
ds_61022_en_txd: 150113D
4
~
5
~
10
4
0
15
~
10
10
6
19
20
~
20
2
0
7000 7200 7400 7600 7800 8000 8200 8400 8600
Surge breakdown voltage, V
9
TX-D
Several part numbers will be discontinued September 30, 2013.
DIMENSIONS (mm inch)
CAD Data
Data from our Web site.
Download CAD
1. Surge breakdown voltage 2,500 V and 6,000 V types
1) Standard PC board terminal
External dimensions
Standard PC board terminal
CAD Data
7.40
.291
15.00
.591
2.54
.100
0.65
.026 8.20
.323
0.50
.020
1.15
.045
2,500 V type
5.08
.200
2.54
.100
3.50
.138
PC board pattern
(Bottom view)
Schematic (Bottom view)
Single side stable
10.16
.400
+
−
5.08
.200
0.25
5.08 .010
.200
8-1.0 dia.
8-.039 dia.
Tolerance: 0.1 .004
1
3 4 5
12
10 9 8
1 coil latching
−
+
1
3 4 5
12
10 9 8
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
CAD Data
6,000 V type
2) Surface-mount terminal
CAD Data
Type
External dimensions (General tolerance: 0.3 .012)
Suggested mounting pad (Top view) (Tolerance: 0.1 .004)
Single side stable and 1 coil latching
Single side stable and 1 coil latching
15
.591
7.4
.291
8.2
.323
SA type
0.5
.020
0.65
.026
5.08
.200
2.54
.100
5.08
.200
9.4±0.5
.370±.020
SS type
0.65
.026
5.08
.200
2.54
.100
2.54
.100
0.25
.010
7.24
.285
7.4
.291
8.2
.323
5.08
.200
8.4
.331
15
.591
0.5
.020
3.16
1
.124 .039
1
2.16
.085 .039
Max.10
.394
5.08
.200
7.4±0.5
.291±.020
0.25
.010
5.08
.200
2.54
.100
6.24
.246
Schematic (Top view)
Single side stable
−
+
12
10 9 8
1
3 4 5
1 coil latching
+
−
12
10 9 8
1
3 4 5
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
10
ds_61022_en_txd: 150113D
TX-D
Several part numbers will be discontinued September 30, 2013.
2. Surge breakdown voltage 6,000 V (High breakdown voltage type)
1) Standard PC board terminal
External dimensions
PC board pattern
Standard PC board terminal
(Bottom view)
CAD Data
7.40
.291
2.54
.100
10.16
.400
15.00
.591
8-1.0 dia.
8-.039 dia.
0.50
.020
5.08
.200
+
−
5.08
.200
0.65 9.45
.026 .372
1.15
.045
Schematic (Bottom view)
Single side stable
2.54
.100
3.50
.138
5.08
.200
0.25
.010
Tolerance: 0.1 .004
1
3 4 5
12
10 9 8
1 coil latching
−
+
1
3 4 5
12
10 9 8
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
General tolerance: 0.3 .012
2) Surface-mount terminal
CAD Data
Type
External dimensions (General tolerance: 0.3 .012)
Suggested mounting pad (Top view) (Tolerance: 0.1 .004)
Single side stable and 1 coil latching
Single side stable and 1 coil latching
7.40
.291
3.16
1
.124 .039
15.00
.591
0.25
.010
SA type
0.50
.020
1.15
.045
9.45
.372
2.54
.100
9.65
.380
0.65
.026
5.08
.200
5.08
.200
2.54
.100
7.24
.285
5.08
.200
9.40±0.5
.370±.020
7.40
.291
15.00
.591
1
2.16
.085 .039
9.45 Max. 11.25
.372
.443
0.25
.010
SS type
0.50
.020
1.15
.045
0.65
.026
5.08
.200
2.54
.100
5.08
.200
2.54
.100
6.24
.246
5.08
.200
7.40±0.5
.291±.020
Schematic (Top view)
Single side stable
−
+
12
10 9 8
1
3 4 5
1 coil latching
+
−
12
10 9 8
1
3 4 5
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
ds_61022_en_txd: 150113D
11
TX-D
Several part numbers will be discontinued September 30, 2013.
NOTES
1. Packing style
1) Tube packing
The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1) stripe
3) Ambient temperature when
transporting and during storage with the
product in its original packaging:
–40 to +70C –40 to +158F
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
A
Stopper (gray)
C
B
Stopper (green)
2) Tape and reel packing (surface-mount
terminal type)
(1) Tape dimensions
(i) SA type
mm inch
1.5 +0.1
0 dia.
Relay polarity bar .059 +.004
dia. 2.0
0
(Z type)
.079
1.75
.069
4.0
.157
0.4
.016
C
A
B
D
11.5
.453
16.0 10.0 .394
.630
TX-D relays
15.5
.610
24.0 ±0.3
±0.2
.945 ±.012 9.2±.008
.362
Tape coming out direction
(ii) SS type
mm inch
1.5 +0.1
0 dia.
Relay polarity bar .059 +.004
dia. 2.0
0
(Z type)
.079
4.0
.157
1.75
.069
0.4
.016
11.5
.453
15.5
.610
TX-D relays
16.0
.630
Tape coming out direction
8.0 24.0 ±0.3
±.012
.315 .945 10.8±0.2
.425±.008
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
3. M.B.B. type
A small OFF time may be generated by
the contact bounce during contact
switching. Check the actual circuit
carefully.
If the relay is dropped accidentally, check
the appearance and characteristics
including M.B.B. time before use.
(2) Dimensions of plastic reel
Min. 10μs
mm inch
±0.6
21 dia.
.827 ±.024 dia.
2.0 ±0.5
.079 ±.020
80 ±1 dia.
3.150 ±.039 dia.
500Ω
5V DC
380 ±2 dia.
14.961 ±.079 dia.
13 ±0.5 dia.
.512 ±.020 dia.
24.4+20
.961+.079
0
Measuring condition of M.B.B. time
±0.2
2.0
.079±.008
For Cautions for Use, see Relay Technical Information.
12
ds_61022_en_txd: 150113D