0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TXD2SS-L-9V-X

TXD2SS-L-9V-X

  • 厂商:

    NAIS(松下)

  • 封装:

    SMD

  • 描述:

    General Purpose Relay DPDT (2 Form C) Surface Mount

  • 数据手册
  • 价格&库存
TXD2SS-L-9V-X 数据手册
Signal Relays ( 2 A or less ) TX-D RELAYS Product Catalog 2022.10 Signal Relays ( 2 A or less ) TX-D RELAYS 6,000 V surge withstand voltage, 2 Form C and 2 A high dielectric strength relays FEATURES Protective construction:Sealed type ● 3,000 Vrms dielectric strength ( Between contact and coil ) 15 ● Surge withstand voltage: 6,000 V (Between contact and coil) 7.4 8.2 ● Approved to the supplementary insulation class in the EN standards ( EN60950 ). ( Clearances: Min. 2.0 mm, creepage distance: Min. 2.5 mm ) 7.4 15 8.4 ● Confort to FCC Part68: Surge withstand voltage 1,500 V ( between open contacts, standard contact ) TYPICAL APPLICATIONS (Unit:mm) ● Telecommunications and modem ● Medical and security equipment ORDERING INFORMATION ( PART NO. : Ordering part number for Japanese market ) ATXD 2 Terminal shape / Operating function 0: Standard PC board terminal type or Surface-mount terminal Single side stable 1: Standard PC board terminal type or Surface-mount terminal 1 coil latching Contact arrangement 2:2 Form C, 2 Form D *1: *2: *3: *4: Contact material*1 Nil: Standard contact(Ag+Au clad) 20: AgPd contact(low level load) ; (stationary) , AgPd+Au clad (movable) AgPd 22 : M.B.B. contact(Ag+Au clad) 28 : M.B.B. contact ; (stationary) AgPd+Au clad , (movable) AgPd Rated coil voltage (DC)*2 0 : 1.5 V, 1 : 3 V, 2 : 6 V, 4 : 24 V, 6 : 4.5 V, 7 : 9 V, 3 : 12 V, 9:5 V Packing style*3 Nil :Tube packing X :Tape and reel(picked from 1/3/4/5-pin side) Z :Tape and reel packing(picked from the 8/9/10/12-pin side) W :Tape and reel packing(picked from 1/3/4/5-pin side) With humidity indicator and silica gel in moisture proof bag*4 Y :Tape and reel packing(picked from 8/9/10/12-pin side) With humidity indicator and silica gel in moisture proof bag*4 Surface-mount type Nil:Standard PC board terminal type SA:SA type SS:SS type M.B.B. type:Single side stable only In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. Packing style symbol“X”,“Z”is not marked on the relay. Each reel is packed with humidity indicators and silica gel in the moisuture proof pack. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー1ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS ORDERING INFORMATION ( TYPE NO. : Ordering part number for non Japanese market ) TXD 2 Surface-mount type Nil:Standard PC board terminal SA:SA type SS:SS type Packing style*3 Nil :Tube packing X :Tape and reel(picked from 1/3/4/5-pin side) Z :Tape and reel packing(picked from the 8/9/10/12-pin side) W :Tape and reel packing(picked from 1/3/4/5-pin side) With humidity indicator and silica gel in moisture proof bag*4 Y :Tape and reel packing(picked from 8/9/10/12-pin side) With humidity indicator and silica gel in moisture proof bag*4 Rated coil voltage(DC)*2 1.5, 3, 4.5, 5, 6, 9, 12, 24V Operating function Nil:Single side stable L :1 coil latching Contact arrangement 2:2 Form C, 2 Form D *1: *2: *3: *4: Contact material*1 Nil :Standard type 2M:M.B.B. type Contact material Nil:Standard contact(Ag+Au clad) 1 :AgPd contact(low level load); AgPd+Au clad(stationary), AgPd(movable) M.B.B. type:Single side stable only In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. Packing style symbol“X”,“Z”is not marked on the relay. Each reel is packed with humidity indicators and silica gel in the moisuture proof pack. TYPES " Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market. ■ Standard contact ● PC board terminal: Tube packing Contact arrangement 2 Form C Rated coil voltage Single side stable 1 coil latching Type No. Part No. Type No. Part No. 1.5 V DC TXD2-1.5V ATXD200 TXD2-L-1.5V ATXD210 3 TXD2-3V ATXD201 TXD2-L-3V ATXD211 4.5 V DC TXD2-4.5V ATXD206 TXD2-L-4.5V ATXD216 5 V DC TXD2-5V ATXD209 TXD2-L-5V ATXD219 6 V DC TXD2-6V ATXD202 TXD2-L-6V ATXD212 V DC 9 V DC TXD2-9V ATXD207 TXD2-L-9V ATXD217 12 V DC TXD2-12V ATXD203 TXD2-L-12V ATXD213 24 V DC TXD2-24V ATXD204 TXD2-L-24V ATXD214 Standard packing Carton ( 1 Tube packing ) Outer carton 40 pcs. 1,000 pcs. Note) Please add " -1 " to the end of the type number or " 20 " to the end of the part number for AgPd contacts ( low level load ). ● Surface-mount terminal SA Type: Tube packing Contact arrangement 2 Form C Rated coil voltage Single side stable 1 coil latching Type No. Part No. Type No. Part No. 1.5 V DC TXD2SA-1.5V ATXD200SA TXD2SA-L-1.5V ATXD210SA 3 TXD2SA-3V ATXD201SA TXD2SA-L-3V ATXD211SA 4.5 V DC TXD2SA-4.5V ATXD206SA TXD2SA-L-4.5V ATXD216SA 5 V DC TXD2SA-5V ATXD209SA TXD2SA-L-5V ATXD219SA 6 V DC TXD2SA-6V ATXD202SA TXD2SA-L-6V ATXD212SA V DC 9 V DC TXD2SA-9V ATXD207SA TXD2SA-L-9V ATXD217SA 12 V DC TXD2SA-12V ATXD203SA TXD2SA-L-12V ATXD213SA 24 V DC TXD2SA-24V ATXD204SA TXD2SA-L-24V ATXD214SA Standard packing Carton ( 1 Tube packing ) Outer carton 40 pcs. 1,000 pcs. Note) Please add " -1 " to the end of the type number or " 20 " to be added in front of " surface-mount type " in part number for AgPd contacts ( low level load ). ● Surface-mount terminal SA Type: Tape and reel packing: Z Contact arrangement 2 Form C Rated coil voltage Single side stable 1 coil latching Type No. Part No. Type No. Part No. 1.5 V DC TXD2SA-1.5V-Z ATXD200SAZ TXD2SA-L-1.5V-Z ATXD210SAZ 3 TXD2SA-3V-Z ATXD201SAZ TXD2SA-L-3V-Z ATXD211SAZ 4.5 V DC TXD2SA-4.5V-Z ATXD206SAZ TXD2SA-L-4.5V-Z ATXD216SAZ 5 V DC TXD2SA-5V-Z ATXD209SAZ TXD2SA-L-5V-Z ATXD219SAZ 6 V DC TXD2SA-6V-Z ATXD202SAZ TXD2SA-L-6V-Z ATXD212SAZ V DC 9 V DC TXD2SA-9V-Z ATXD207SAZ TXD2SA-L-9V-Z ATXD217SAZ 12 V DC TXD2SA-12V-Z ATXD203SAZ TXD2SA-L-12V-Z ATXD213SAZ 24 V DC TXD2SA-24V-Z ATXD204SAZ TXD2SA-L-24V-Z ATXD214SAZ Standard packing Carton ( 1 Reel packing ) Outer carton 500 pcs. 1,000 pcs. Notes) 1: Please add " -1 " to the end of the type number or " 20 " to be added in front of " surface-mount type " in part number for AgPd contacts ( low level load ). 2: For taping packaging X, W, and Y, change " Z " at the end of the part number to " X ", " W ", and " Y ". Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS ■ M.B.B. Contact ● PC board terminal/Surface-mount terminal SA Type: Tube packing Contact arrangement 2 Form D Rated coil voltage PC board terminal Surface-mount terminal Single side stable Single side stable Type No. Part No. Type No. Part No. 1.5 V DC TXD2-2M-1.5V ATXD20022 TXD2SA-2M-1.5V ATXD20022SA 3 TXD2-2M-3V ATXD20122 TXD2SA-2M-3V ATXD20122SA 4.5 V DC TXD2-2M-4.5V ATXD20622 TXD2SA-2M-4.5V ATXD20622SA 5 V DC TXD2-2M-5V ATXD20922 TXD2SA-2M-5V ATXD20922SA 6 V DC TXD2-2M-6V ATXD20222 TXD2SA-2M-6V ATXD20222SA V DC 9 V DC TXD2-2M-9V ATXD20722 TXD2SA-2M-9V ATXD20722SA 12 V DC TXD2-2M-12V ATXD20322 TXD2SA-2M-12V ATXD20322SA 24 V DC TXD2-2M-24V ATXD20422 TXD2SA-2M-24V ATXD20422SA Standard packing Carton ( 1 Tube packing ) Outer carton 40 pcs. 1,000 pcs. Note) Please add " -1 " to the end of the type number or " 28 " to be added in front of " surface-mount type " in part number for AgPd contacts ( low level load ). ● Surface-mount terminal SA Type: Tape and reel packing: Z Contact arrangement 2 Form D Rated coil voltage Single side stable Type No. Standard packing Part No. 1.5 V DC TXD2SA-2M-1.5V-Z ATXD20022SAZ 3 TXD2SA-2M-3V-Z ATXD20122SAZ 4.5 V DC TXD2SA-2M-4.5V-Z ATXD20622SAZ 5 V DC TXD2SA-2M-5V-Z ATXD20922SAZ 6 V DC TXD2SA-2M-6V-Z ATXD20222SAZ V DC 9 V DC TXD2SA-2M-9V-Z ATXD20722SAZ 12 V DC TXD2SA-2M-12V-Z ATXD20322SAZ 24 V DC TXD2SA-2M-24V-Z ATXD20422SAZ Carton ( 1 Reel packing ) Outer carton 500 pcs. 1,000 pcs. Notes) 1: Types designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered. However, please contact us if you need parts for use in low level load. ( Ex. ATXD***28 ) 2: For taping packaging X, W, and Y, change " Z " at the end of the part number to " X ", " W ", and " Y ". Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー3ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS RATING ■ Coil data • Operating characteristics such as " Operate voltage " and " Release voltage " are influenced by mounting conditions or ambient temperature, etc. Therefore, please use the relay within ±5 % of rated coil voltage. • " Initial " means the condition of products at the time of delivery. ● Standard contact: Single side stable Rated coil voltage Operate voltage* ( at 20 ℃ ) Release voltage* ( at 20 ℃ ) 1.5 V DC 3 Rated operating current ( ±10 %, at 20 ℃ ) 132.7 mA V DC 66.7 mA 4.5 V DC 44.4 mA 5 V DC 6 V DC Max. 75 % V of rated coil voltage ( Initial ) Min. 10 % V of rated coil voltage ( Initial ) 40 Coil resistance ( ±10 %, at 20 ℃ ) Rated operating power Max. allowable voltage ( at 20 ℃ ) 11.3 Ω 45 Ω 101.3 Ω mA 125 Ω 33.3 mA 180 Ω 9 V DC 22.2 mA 405 Ω 12 V DC 16.7 mA 720 Ω 24 V DC 9.6 mA 200 mW 2,504.3 Ω 230 mW Coil resistance ( ±10 %, at 20 ℃ ) Rated operating power 120 % V of rated coil voltage * square, pulse drive ● Standard contact: 1 coil latching Rated coil voltage Set voltage* ( at 20 ℃ ) Reset voltage* ( at 20 ℃ ) 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC Max. 75 % V of rated coil voltage ( Initial ) Max. 75 % V of rated coil voltage ( Initial ) Rated operating current ( ±10 %, at 20 ℃ ) 100 mA 50 mA 60 Ω 33.3 mA 135 Ω 30 mA 166 Ω 25 mA 240 Ω 16.7 mA 540 Ω Max. allowable voltage ( at 20 ℃ ) 15 Ω 150 mW 9 V DC 12 V DC 12.5 mA 960 Ω 24 V DC 7.1 mA 3,388 Ω 170 mW Coil resistance ( ±10 %, at 20 ℃ ) Rated operating power 120 % V of rated coil voltage * square, pulse drive ● M.B.B. Contact: Single side stable Rated coil voltage Operate voltage* ( at 20 ℃ ) Release voltage* ( at 20 ℃ ) 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC Rated operating current ( ±10 %, at 20 ℃ ) 166.7 mA 9Ω 83.3 mA 36 Ω 55.6 mA Max. 75 % V of rated coil voltage ( Initial ) Min. 10 % V of rated coil voltage ( Initial ) 50 Max. allowable voltage ( at 20 ℃ ) 81 Ω mA 100 Ω 41.7 mA 144 Ω 9 V DC 27.8 mA 324 Ω 12 V DC 20.8 mA 576 Ω 24 V DC 11.3 mA 2,133 Ω 250 mW 120 % V of rated coil voltage 270 mW * square, pulse drive Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー4ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS ■ Specifications Item Contact data Specifications Contact arrangement 2 Form C Contact resistance ( initial ) Max. 100 mΩ (by voltage drop 6 V DC 1 A) Contact material Standard contact: Ag + Au clad AgPd contact ( low level load ): AgPd + Au clad ( stationary ), AgPd ( movable ) Contact rating ( resistive ) Standard contact: 2 A 30 V DC AgPd contact: 1 A 30 V DC 1 A 30 V DC Max. switching power ( resistive ) Standard contact: 60 W ( DC ) AgPd contact: 30 W ( DC ) 30 W ( DC ) Max. switching voltage 220 V DC 110 V DC Max. switching current Standard contact: 2 A ( DC ) AgPd contact: 1 A ( DC ) 1 A ( DC ) Min. switching load ( reference value )*1 10 µA 10 mV DC Insulation resistance ( initial ) 2 Form D ( M.B.B.type ) Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. ) Dielectric strength ( initial ) Between open contacts 1,000 Vrms for 1 min ( detection current: 10 mA ) Between contact and coil 3,000 Vrms for 1 min ( detection current: 10 mA ) Between contact sets 1,000 Vrms for 1 min ( detection current: 10 mA ) Surge withstand voltage ( initial ) Between open contacts 1,500 V 10 × 160 µs Between contact and coil 6,000 V 1.2 × 50 µs Time characteristics ( initial ) Operate [ Set ] time Max. 4 ms at rated coil voltage ( at 20 ℃, without bounce ) [Max. 4 ms ( at 20 ℃, without bounce ) ] Release [ Reset ] time Max. 4 ms at rated coil voltage ( at 20 ℃, without bounce, without diode ) [ Max. 4 ms ( at 20 ℃, without bounce ) ] Shock resistance Functional 750 m/s2 ( half-sine shock pulse: 6 ms, detection time: 10 µs ) Destructive 1,000 m/s2 ( half-sine shock pulse: 6 ms ) Vibration resistance Functional 10 to 55 Hz ( at double amplitude of: 3.3 mm, detection time: 10 µs ) Destructive 10 to 55 Hz ( at double amplitude of: 5 mm ) Expected life Mechanical life Min. 100 × 106 ope. ( Switching frequency: at 180 times/min ) Conditions Conditions for usage, transport and storage*2 Ambient temperature: −40 to +85 ℃ ( Allowable temperature is from −40 to +70 ℃ at our standard packing condition. ) Humidity: 5 to 85 % RH ( Avoid icing and condensation ) Unit weight 500 Vrms 1 min ( detection current: 10 mA ) − 500 m/s2 ( half-sine shock pulse: 11 ms, detection time: 10 µs ) Min. 10 × 106 ope. ( Switching frequency: at 180 times/min ) Approx. 2 g Note) For AC load, please inquire our sales office for details. *1: This value is a rough indication of the lower limit at which switching is possible at micro load level. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. AgPd contact is recommended for low level load ( Max. 10 V DC, 10 mA level ). *2: For ambient temperature, please refer to the " GUIDELINES FOR RELAY USAGE ". ■ Electrical life Conditions: resistive load, switching frequency at 20 times/minute Type 2 Form C 2 Form D ( M.B.B.contact ) Switching capacity Number of operations 1 A 30 V DC Min. 500 x 103 ope. 2 A 30 V DC Min. 100 x 103 ope. 1 A 30 V DC Min. 100 x 103 ope. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS REFERENCE DATA 1. Max. switching capacity 2. Switching life curve 3 No. of operations, ×104 DC resistive load 0.5 0.4 0.3 0 20 30 70 Temperature rise, ° C 40 2A 2A 20 0A 0A 40 0 110 120 Coil applied voltage, %V 5. Mechanical life 50 +25° C C +70° 100 Max. Min. 50 40 Release voltage 30 Max. Min. 20 10 10 100 1,000 No. of operations, ×104 10,000 Ratio against the rated voltage, %V 60 0 Operate voltage 20 40 -10 -20 Ave. 60 80 100 Ambient C temperature, ° -30 -40 -50 110 120 Coil applied voltage, %V Change of operate and release voltage 90 70 Ave. 20 Tested sample:TXD2-5V, 6 pcs. Operating speed:20 cpm 100 Operatevoltage 30 6. Electrical life test ( 2 A 30 V DC resistive load ) Tested sample:TXD2-5V, 10 pcs. Operating speed:180 cpm 80 -40 -20 Release voltage 0 40 10 -60 0A 0A 20 0 0 0 Tested sample:TXD2-5V, 5 pcs. 2A 2A 30 10 100 4. Ambient temperature characteristics ( Average ) 50 10 0 1 2 Switching capacity, A 60 50 30 0 Tested sample:TXD2-24V, 6 pcs. Measured portion:Inside the coil Ambient temperature:25° C, 70° C 70 +25° C +70° C 60 30V DC resistive load 3-2. Coil temperature rise value ( Average ) Tested sample:TXD2-5V, 6 pcs. Measured portion:Inside the coil Ambient temperature:25° C, 70° C Temperature rise, ° C 20 0 50 100 200 300 Contact voltage, V 3-1. Coil temperature rise value ( Average ) Ratio against the rated voltage, %V 30 10 0.2 0 50 Variation ratio, % 1 100 Change of contact resistance 100 100 90 90 80 Operate voltage 70 Max. Min. 60 50 Release voltage 40 Max. 30 20 Min. 10 0 Contact resistance, mΩ Contact current, A 2 80 70 60 Max. 50 40 Min. 30 20 10 0 2 4 6 8 No. of operations, ×104 10 0 0 2 4 6 8 No. of operations, ×104 10 Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー6ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS 7-1. Operate and release time ( without diode ) 7-2. Operate and release time ( with diode ) Tested sample:TXD2-5V, 10 pcs. Operate time Release time Max. Min. 3 2 Max. Min. 1 0 0 70 80 90 100 110 120 Coil applied voltage, %V Rate of change, % Rate of change, % Tested sample:TXD2-12V, 6 pcs. 5 ON ON 0 ℓ ℓ Operate voltage ON -5 -10 10 OFF OFF 5 ℓ ℓ Release voltage OFF -5 2 1,000 Y 4 Deenergized condition Energized condition Max. Z X 3 Min. 2 Max. Min. Z’ X’ ZX Z’ Y Y’ 0 70 80 X’ Y’ 90 100 110 120 Coil applied voltage, %V 9-2. Influence of proximity mounting 10 6 8 10 Inter-relay distance ℓ, mm ℓ 0 ℓ Operate voltage ON -5 ON -10 10 OFF 5 ℓ 0 ℓ Release voltage OFF -5 OFF 2 4 6 8 10 Inter-relay distance ℓ, mm 10-2. High frequency characteristics ( Insertion loss ) Tested sample:TXD2-12V, 2 pcs. Insertion loss, dB Tested sample:TXD2-12V, 2 pcs. ON 5 -10 0 10-1. High frequency characteristics ( Isolation ) Isolation, dB [m/s2] Tested sample:TXD2-12V, 6 pcs. 10 -10 0 4 0 9-1. Influence of proximity mounting 0 Operate time Release time 1 Rate of change, % 4 Tested sample:TXD2-5V, 6 pcs 5 Rate of change, % Operate and release time, ms 5 Operate and release time, ms Tested sample:TXD2-5V, 10 pcs. 8. Functional shock ( Single side stable ) 100 1 0.8 0.6 50 0.4 0.2 0 10 0 100 Frequency, MHz 0 1,000 0 10 100 Frequency, MHz 1,000 11-1. Distribution of M.B.B. time Tested sample:TXD2-2M-5V, 50 pcs. Terminal No. 3-4-5:ON Terminal No. 3-4-5:OFF 60 50 40 30 Ave.:298.8μs σn-1 : 51.8μs Min.:205 μs Max.:432 μs 50 Quantity, n Quantity, n 60 Ave.:300.5μs σn-1 : 55.3μs Min.:165 μs Max.:415 μs 40 30 22 20 20 12 10 7 0 100 150 150 200 1 200 250 250 300 300 350 13 200 250 250 300 16 8 10 6 2 12 350 400μs min. 400 450μs max. 0 1 100 150 150 200 300 350 350 400μs min. 400 450μs max. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー7ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS 11-2. Distribution of M.B.B. time 12. Surge withstand voltage test Tested sample:TXD2-2M-5V, 50 pcs. Terminal No. 8-9-10:ON 3-4-5:: Terminal No. 8-9-10 OFF OFF Ave.:293.4μs σn-1 : 60.4μs Min.:155 μs Max.:445 μs 40 30 18 20 10 10 0 100 150 150 200 200 250 250 300 300 350 30 19 10 5 4 3 0 350 400μs min. 400 450μs max. 12 40 20 10 14 Ave.:281.4μs σn-1 : 58.3μs Min.:120 μs Max.:421 μs 50 Quantity, n Quantity, n 50 Tested sample:TXD2-3V, 30 pcs. 60 Quantity, n 60 1 100 150 6 4 150 200 15 200 250 300 350 8 6 4 2 4 250 300 10 1 0 7,000 7,200 7,400 7,600 7,800 8,000 8,200 8,400 8,600 Surge withstand voltage, V 350 400μs min. 400 450μs max. DIMENSIONS ( Unit: mm ) CAD The CAD data of the products with a " CAD " mark can be downloaded from our Website. ■ PC board terminal ● Single side stable/1 coil latching CAD External dimensions Recommended PC board pattern ( BOTTOM VIEW ) 7.4 10.16 2.54 3 5 12 10 9 Direction indication 8 5.08 1 − 8 φ1 0.65 8.2 Tolerance:±0.1 3.5 5.08 4 + 15 0.5 1.15 Schematic ( BOTTOM VIEW ) Single side stable ( De-energize ) 2.54 1 coil latching ( Reset ) 0.25 5.08 4 5 12 10 9 Direction indication 8 − General tolerance : ±0.3 1 3 + ■ Surface-mount terminal ● Single side stable/1 coil latching CAD Recommended PC board pattern ( TOP VIEW ) External dimensions 7.4 Type Schematic ( TOP VIEW ) Single side stable ( De-energize ) 10 9 8 3 4 1 Direction indication 5 − 12 5.08 3.16 15 2.54 0.5 1.15 5.08 8.4 0.25 0.65 8.2 7.24 SA 1 Tolerance:±0.1 5.08 9.4±0.5 2.54 + 1 coil latching ( Reset ) 10 9 8 1 3 4 Direction indication 5 + 12 General tolerance : ±0.3 − Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー8ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS PACKING STYLE ( Unit: mm ) ■ Tube packing Orientation(indicates PIN No.1)stripe 1) The relay is packing in a tube with the relay orientation mark on the left side,as shown in the figure below. Be sure to maintain relays in the correct orientation when mounting on PC boards. 2) Conditions for operation, transport and storage: −40 to 70 ℃. Stopper(gray) Stopper(green) ■ Taping packaging 1) Tape dimensions SA Type φ21±0.8 16 TX-D relays 0.4 2±0.5 9.2±0.2 φ380±2 4 φ80±1 2 15.5 +0.1 φ1.5   0 11.5 1.75 24±0.3 Relay polarity bar (Z type) 2) Dimensions of plastic reel Tape coming out direction φ13±0.2 24.4+ 20 2±0.2 3) Conditions for operation, transport and storage: ‒40 to 70 ℃. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー9ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS EXAMPLE OF RECOMMENDED SOLDERING CONDITIONS ■ For cautions for use, please read " Relay Soldering and Cleaning Guidelines " and " SMT Soldering Guidelines ". ■ PC board terminal In case of hand soldering, the following conditions should be observed. The effect on the relay depends on the PC board used. Please verify the actual PC board to be used. ● Automatic soldering ( Flow ) Recommended conditions Temperature Preheating Soldering ● Hand soldering Time Measurement location Recommended conditions Temperature Time Measurement location Max. 120 ℃ Within 120 seconds Solder surface terminal Soldering Max. 350 ℃ Within 3 seconds Tip temperature 260 ℃ ±5 ℃ Within 6 seconds Solder temperature ■ Surface-mount terminal In case of automatic soldering ( reflow ), the following conditions should be observed. ● IRS ( infrared reflow soldering method ) heating conditions Recommend conditions Number of reflow 1 time Measuring position Surface of PC board where relay is mounted. t4 T3 T2 T1 t1 t2 t3 t 1=60s to 120s t 2=within 20s t 3=within 30s C) t 4=within 10s(245 to 250° T1=150 to 180° C C and higher T2=230° C max T3=250° ● Mounting cautions Cautions to observe when mounting temperature increases in the relay are greatly dependent on the way different parts are located a PC board and the heating method of the reflow device. Therefore, please conduct testing on the actual device beforehand after making sure the parts soldered on the relay terminals and the top of the relay case are within the temperature conditions. Measuring position of temperature profile Note Note:7KHVROGHULQJWHPSHUDWXUHSURŏOH indicates the pad temperature. In some cases, the ambient temperature may be greatly LQFUHDVHG&KHFNIRUWKHVSHFLŏF mounting condition. ■ Other things to observe • Exceeding the stipulated conditions when soldering may affect coaxial switch performance. Be sure to consult us beforehand. • Since thermal stress on a relay will depend on the PC board and process conditions, please be sure to test using the actual PC board. • Creep-up, wettability and solder strength will differ depending on changes in the mounting conditions and type of solder. Please evaluate based on actual production conditions. • Only apply coating after the relay has returned to room temperature. SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information. ■ UL/C-UL ( Approved ) File No. Contact rating Operations A 30 V DC Resistive 100 × 103 40 ℃ 0.5 A 125 V AC Resistive 100 × 103 40 ℃ 0.3 A 110 V DC Resistive 100 × 103 40 ℃ 2 E43149 ■ CSA ( Approved ) Ambient temperature CSA standard approved by C-UL. ■ BSI ( Approved ) BSI standard approved by File No. VC670289 ( Supplementary insulation ). Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 10 ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 Signal Relays ( 2 A or less ) TX-D RELAYS GUIDELINES FOR USAGE ■ For cautions for use, please read " GUIDELINES FOR SIGNAL RELAYS USAGE " and " GUIDELINES FOR RELAY USAGE ". ■ Cautions for usage of TX-D relay ● Latching • Use latching when conditions involve continuous carrying current. • Regarding the set and reset pulse time, for the purpose of reliable operation under ambient temperature fluctuations and different operating conditions, we recommend setting the coil applied set and reset pulse time to 10 ms or more at the rated coil voltage. • The relay is shipped in the reset position. But jolts during transport or impacts during installation can change the reset position. It is, therefore, advisable to build a circuit in which the relay can be initialized ( set and reset ) just after turning on the power. ● External magnetic field Since TX-D relays are highly sensitive polarized relays, their characteristics will be af ected by a strong external magnetic field. Avoid using the relay under that condition. ● Precautions for usage of automatic insertion machine Set the chucking pressure of the pick-up mechanism by the automatic mounting machine with the pressure shown in table 1 to maintain the internal function of the relay. E A D C B Please chuck the   portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be also avoided. Table 1: Chucking pressure A, B and D direction Max. 9.8 N ( 1 kgf ) C and E direction Max. 4.9 N ( 500 gf ) ● M.B.B. contact A small OFF time may be generated by the contact bounce during contact switching. Check the actual circuit carefully. Min. 10μs 500Ω 5V DC Measuring condition of M.B.B. time Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 11 ー Panasonic Industry Co., Ltd. 2022 ASCTB19E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE ■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ". https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp PRECAUTIONS FOR COIL INPUT ■ Long term current carrying ■ Coil connection A circuit that will be carrying a current continuously for long periods without relay switching operation. ( circuits for emergency lamps, alarm devices and error inspection that, for example, revert only during malfunction and output warnings with form B contacts ) Continuous,long-term current to the coil will facilitate deterioration of coil insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type latching relay. If you need to use a single stable relay, use a sealed type relay that is not easily affected by ambient conditions and make a failsafe circuit design that considers the possibility of contact failure or disconnection. When connecting coils of polarized relays, please check coil polarity ( +, − ) at the internal connection diagram ( Schematic ). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and so on, and circuit do not work. Avoid impressing voltages to the set coil and reset coil at the same time. ■ DC Coil operating power Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5 %. However, please check with the actual circuit since the electrical characteristics may vary. The rated coil voltage should be applied to the coil and the set/reset pulse time of latching type relay differs for each relays, please refer to the relay's individual specifications. ■ Maximum allowable voltage and temperature rise Proper usage requires that the rated coil voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum continuous voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog. ● Operate voltage change due to coil temperature rise ( hot start ) In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the operate voltage will become somewhat higher. Also, it will be the same as using it in a higher temperature atmosphere. The resistance/temperature relationship for copper wire is about 0.4 % for 1 ℃, and with this ratio the coil resistance increases. That is, in order to operate of the relay, it is necessary that the voltage be higher than the operate voltage and the operate voltage rises in accordance with the increase in the resistance value. However, for some polarized relays, this rate of change is considerably smaller. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 12 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE NOTES ■ Usage, Storage, and Transport Conditions During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. 1) Temperature: The allowable temperature range differs for each relay, so refer to the relay's individual specifications. In addition, when transporting or storing relays while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. 2) Humidity: 5 to 85% RH The humidity range varies with the temperature. Use within the range indicated in the graph. ( The allowable temperature depends on the relays. ) ● Condensation Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay and microwave device is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation causes the failures like insulation deterioration, wire disconnection and rust etc. Panasonic Industry Co., Ltd. does not guarantee the failures caused by condensation. The heat conduction by the equipment may accelerate the cooling of device itself, and the condensation may occur. Please conduct product evaluations in the worst condition of the actual usage. ( Special attention should be paid when high temperature heating parts are close to the device. Also please consider the condensation may occur inside of the device. ) Humidity (% RH) ● Icing Condensation or other moisture may freeze on relays when the temperature become lower than 0 ℃. This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Industry Co., Ltd. does not guarantee the failures caused by the icing. The heat conduction by the equipment may accelerate the cooling of relay itself and the icing may occur. Please conduct product evaluations in the worst condition of the actual usage. 85 Allowable range Avoid icing when used at temperatures lower than 0°C Avoid condensation when used at temperatures higher than 0°C 5 -40 0 85 Ambient temperature (℃) 3) Pressure: 86 to 106 kPa ● Low temperature and low humidity The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. ● High temperature and high humidity Storage for extended periods of time ( including transportation periods ) at high temperature or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. ● Package In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 13 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE ● Storage requirements Since the surface-mount terminal type is sensitive to humidity it is packaged with tightly sealed anti-humidity packaging. However, when storing, please be careful of the following. 1) Please use promptly once the anti-humidity pack is opened. ( within 72 hours, Max. 30 ℃ / 70% RH ). If left with the pack open, the relay will absorb moisture which will cause thermal stress when reflow mounting and thus cause the case to expand. As a result, the seal may break. 2) If relays will not be used within 72 hours, please store relays in a humidity controlled desiccator or in an antihumidity bag to which silica gel has been added. 4 ) The following cautionary label is affixed to the antihumidity pack. * If the relay is to be soldered after it has been exposed to excessive humidity atmosphere, cracks and leaks can occur. Be sure to mount the relay under the required mounting conditions. 3) When relays ( which is packaged with humidity indicator and silica gel ) meeting one of below criteria, please bake ( dry ) before use. • When the storage conditions specified in 1) are exceeded. • When humidity indicator is in Ⅲ or Ⅳ status according to judgement standard. Please check humidity indicator color and decide if baking is necessary or not. ●: indicate brown, ○: Other than brown ( blueish color ) 5% 10% 60% Bake treatment necessity judgment Ⅰ ● ● ● No need to bake Ⅱ ○ ● ● No need to bake Ⅲ ○ ○ ● Need to bake Ⅳ ○ ○ ○ Need to bake Spot 5% 10% ● Silicon When a source of silicone substances ( silicone rubber, silicone oil,silicone coating materials and silicone filling materials etc. ) is used around the relay, the silicone gas ( low molecular siloxane etc. ) may be produced This silicone gas may penetrate into the inside of the relay. When the relay is kept and used in this condition, silicone compound may adhere to the relay contacts which may cause the contact failure. Do not use any sources of silicone gas around the relay ( Including plastic seal types ). ● NOx Generation When relay is used in an atmosphere high in humidity to switch a load which easily produces an arc, the NOx created by the arc and the water absorbed from outside the relay combine to produce nitric acid. This corrodes the internal metal parts and adversely affects operation. Avoid use at an ambient humidity of 85 % RH or higher ( at 20 ℃ ). If use at high humidity is unavoidable, please contact our sales representative. 60% Humidity indicator card <Baking ( Drying ) conditions> • With reel : 45 ℃, 96 hours or more. • Without reel ( including relay only ): 60 ℃, 35 hours or more. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 14 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE OTHERS ■ Cleaning • Although the environmentally sealed type relay (plastic sealed type,etc. ) can be cleaned, avoid immersing the relay into cold liquid ( such as cleaning solvent ) immediately after soldering. Doing so may deteriorate the sealing performance. • Surface-mount terminal type relay is sealed type and it can be cleaned by immersion. Use pure water or alcohol-based cleaning solvent. • Cleaning with the boiling method is recommended ( The temperature of cleaning liquid should be 40℃ or lower ). Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may cause breaks in the coil or slight sticking of the contacts due to the ultrasonic energy. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 15 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 ■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ©Panasonic Industry Co., Ltd. 2022 Specifications are subject to change without notice. モヴヤヵャヒペユチチチビパビビヒパ 2022.10
TXD2SS-L-9V-X 价格&库存

很抱歉,暂时无法提供与“TXD2SS-L-9V-X”相匹配的价格&库存,您可以联系我们找货

免费人工找货