0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
UGRC1Y04R

UGRC1Y04R

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    Y04R RELAY OUTPUT UNIT

  • 数据手册
  • 价格&库存
UGRC1Y04R 数据手册
Green Room System Controller Board GR-C SERIES Making Guest Rooms More Comfortable! 2012.09 Features Ethernet compatible Easy maintenance Capable of central management, control, and remote program changing Power consumption monitoring available The Y04R Relay output units have a removable connector that eliminates the need for rewiring work. Use in combination with Eco-POWER METER allows for visualization of power consumptions in hotel rooms, which will raise guests’ awareness regarding energy saving. ■SYSTEM CONFIGURATION Equipped with 16 relay outputs as standard Built-in overcurrent protection fuse ensure safe use. Communication channel 0 (USB) Program loader Communication channel 1 (Ethernet) PC Communication channel 2 (RS485 Port 2) Eco-POWER METER Card key switch Lighting ● Switch for lighting ● Fan coil switch ● Motion sensor ● Pattern lighting control ● Control linked to motion sensors Temperature sensor ● 0 to 50 °C 32 to 122 °F ● 0 to 60 °C 32 to 140 °F ● 0 to 100 °C 32 to 212 °F Spare terminals ● For common connection wiring Fan coil Power supply ● High, medium and low speed ● Temperature control ● 24 V DC *A separate program is required to operate this controller board. Please contact us for information about the program. ■PRODUCT TYPE Type Product name Controller board set (all-in-one type) GR-C1 Controller board set Contents of set Model No. CPU unit × 1, Input unit × 1, Y04R Relay output unit × 4, MRTC Master memory board with real-time clock × 1 and Mounting plate × 1 UGRC1S001 ■MAINTENANCE PARTS AND OPTIONS Product name Specifications Model No. Y04R Relay output unit 4-point relay output unit, harness and connector (one set each) The 4-point relay output unit to be connected to the input unit with a harness UGRC1Y04R SD01 Serial data board RS232C, 4 channels, Three-wire system (non-insulated), 115.2 kbps (Mounting spacer and screws supplied) ABXSD01 AD02 Analog input board 2 channels, 12 bits, non-insulated, 0 to 10 V / 0 to 20 mA switchable, Accuracy: ±1 % F.S. (Mounting spacer and screws supplied) ABXAD02 Backup battery CR2450-equivalent button battery Required for backup of the data register and use of the real-time clock function as a backup battery AFC8801 Discrete-wire press socket For connecting the AD02 Analog input board (add-on function board) AFP0807 (2 pieces) Connector set for flat cable (10 leads) For simple connection using a flat cable I/O cable for MIL connector type (10 leads) Discrete-wire cable (10 leads) with connectors attached at one end, AWG22, 0.3 mm2, 1 set: 2 cables (blue and white), For MIL connector type I/O cable AFP0808 (4 pieces) Length: 1 m 3.3 ft AFP0521 (2 cable set) Length: 3 m 9.8 ft AFP0523 (2 cable set) Green Room System Controller Board GR-C SERIES ■CONTROLLER BOARD SET SPECIFICATIONS General specifications Item Specifications Operating environment Breakdown voltage Temperature: 0 to 40 °C 32 to 104 °F Storage temperature: −40 to 70 °C −40 to 158 °F Humidity: 10 to 95 % RH (at 25 °C 77 °F, no condensation) Atmospheric pressure: 86 to 106 kPa 500 V AC for 1 minute, Cutoff current: 10 mA [except capacitor for protection (initial value at shipment)] • Input terminals, relay output terminals and RS485 terminals ↔ DC power and Functional ground (F.G.) terminals • Input terminals, relay output terminals and analog input terminals ↔ RS485 terminals • RS485 Port 1 terminals ↔ RS485 Port 2 terminals • DC power ↔ Functional ground (F.G.) terminals 1,500 V AC for 1 minute, Cutoff current: 10 mA • Relay output terminals ↔ Other terminals (except RJ45 connector) • Between COM terminals of relay output unit Insulation resistance 100 MΩ or more (500 V DC using an insulation resistance meter) (Measurement location is the same as breakdown voltage.) Vibration resistance Frequency: 5 to 9 Hz (single amplitude: 3.5 mm 0.14 in), Frequency: 9 to 150 Hz (constant acceleration: 9.8 m/s2), Sweep time: 1 octave/min, X, Y and Z directions: 10-sweep each (98 minutes) Shock resistance 147 m/s2 or more, 3 times each in 6 directions Noise immunity 1,000 V (p-p) with pulse widths 50 ns and 1 μs (at DC power terminal), 1,500 V (p-p) with pulse widths 50 ns and 1 μs (at relay output terminal) (using noise simulator) Dimensions (W × H × D) 225 × 215 × 50 mm 8.86 × 8.46 × 1.97 in Weight (Packing weight) 1.1 kg approx. (1.4 kg approx.) Power supply specifications Item Analog specifications input of main unit Specifications Item Specifications Rated voltage 24 V DC Number of points 4 points Voltage fluctuation range 21.6 to 26.4 V DC Input type Voltage input: 0 V to 10 V, Absolute maximum input voltage: 10 V Current consumption 400 mA or less (at 24 V DC, 25 °C 77 °F) (Note) Input impedance 100 kΩ Inrush current 20 A or less (at 24 V DC, 25 °C 77 °F) Resolution 10 bits (K0 to K1000) Allowable momentary power off time 5 ms (at 24 V DC, 25 °C 77 °F) Input precision range 0.1 to 9.9 V Insulation system Not isolated from the internal control circuit Precision ±2.5 % F.S. (F.S. = 10 V) Fuse Built-in (not replaceable) Insulation method Not isolated from the internal control circuit Input terminal Terminal block: Weidmuller LM 5.00/03/90 3.5SN OR BX Input points per common Common (GND), 1 terminal per common connection (4 terminals in total) Input terminal Terminal block: Weidmuller PS 3.50/08/90 3.5SN OR BX Note: Without the function board mounted (with ABXMRTC mounted) Input specifications Analog input circuit diagram of main unit Specifications Number of points 16 points Insulation method Isolated from the internal control circuit by a photocoupler Operating voltage range External input: 21.6 to 26.4 V DC/AC (50 Hz/60 Hz) Rated input current 4.3 mA approx. Input points per common 8 points/common (Either the positive or negative of the input voltage can be connected to the common terminal.) 3.3 V A_IN□ 67 kΩ VREF 100 Ω VIN 33 kΩ GND Min. ON voltage/Min. ON current 19.2 V DC/3 mA (Between common and input) Internal circuit Item Max. OFF voltage/Max. OFF current 2.4 V DC/1 mA (Between common and input) Input impedance 5.6 kΩ approx. Response time 25 ms or less Input terminal Terminal block: Weidmuller PS 3.50/08/90 3.5SN OR BX Communication specifications Item Input circuit diagram Internal circuit X_common-□ 1 kΩ X□ Specifications Communication standard USB / RS485 (Switch selectable) 5.6 kΩ Communication function MEWTOCOL* / General-purpose communication Communication speed USB / RS485 Port 1: 2,400 bps to 115.2 kbps Communication channel 0 Insulation method (USB / RS485 Port 1) Communication terminal Relay output specifications Item Number of points Output type 1 Form A relay output (Not replaceable) Maximum control capacity 250 V AC/2 A resistive load Fluorescent bulb of 22 W or below: Up to two fluorescent bulbs per one output (Note) Minimum control capacity 100 mA 5 V DC Switching life 100,000 operations or more (250 V AC/2 A: Resistive load) Output points per common 1 common every 2 points, 8 common in total (The common terminals are isolated from one another.) 1 terminal per common connection Protection Equipped with a fuse for overcurrent protection (Not replaceable) Operating indicator LED indicator Output terminal Removable terminal block: Weidmuller BLZP 5.08/06/180SN OR BX USB: B connector RS485 Port 1: Terminal block Weidmuller PS 3.50/08/ 90 3.5SN OR BX [Connected to Communication Channel 2 (RS485 Port 2)] Communication standard IEEE802.3u Specifications 16 points (4 points × 4 units, connected to the input unit with a harness for the relay output unit) USB: Not isolated from the internal control circuit RS485: Isolated from the internal control circuit by a photocoupler Communication Communication function channel 1 Communication speed (Ethernet) MEWTOCOL* / General-purpose communication / PC (PLC) link / Modbus RTU Internet protocol (IP): Compatible with version 4 (IPv4) only 10 Mbps / 100 Mbps Insulation method Isolated from the internal control circuit by a pulse transformer Communication terminal RJ45 connector Communication standard RS485 Note: If more than two bulbs need to be controlled, add relays externally. Output circuit diagram Y_common-□ Relay FUSE 2.5 A Y□ Communication function Communication channel 2 Communication speed (RS485 Port 2) Insulation method Communication terminal MEWTOCOL* / General-purpose communication / Modbus RTU 9,600 bps / 19,200 bps / 115.2 kbps Isolated from the internal control circuit by a photocoupler Terminal block: Weidmuller PS 3.50/08/90 3.5SN OR BX [Connected to Communication Channel 0 (RS485 Port 1)] *MEWTOCOL: Our company's dedicated communication protocol. Use for communication with the Eco-POWER METER. Add-on functions Item Specifications Function boards Function board: Up to two boards can be mounted. (Note 1) Usable function boards AD02 Analog input board (Model No.: ABXAD02) MRTC Master memory board with real-time clock (Note 2) (Model No.: ABXMRTC) SD01 Serial data board (Model No.: ABXSD01) Notes: 1) One ABXMRTC board has already been mounted on the board set. 2) With regard to ABXMRTC, only one board can be mounted. Green Room System Controller Board GR-C SERIES ■NAME AND DIMENSIONS (Unit: mm in) GR-C1 Controller board set SD01 Serial data board (separately sales) AD02 Analog input board (separately sales) 225 8.86 (50) (1.97) 210 8.27 115 4.53 80 3.15 4.6 0.18 ø9.2 ø0.36 (11.7) (0.46) 50 1.97 55 2.17 Mounting plate (supplied) RS-485 USB Backup battery (separately sales) 6 5 4 3 RUN 184 7.24 2 1 181.6 7.15 215 8.46 200 7.87 PROG X0 X4 X8 XC Y0 Y4 Y8 YC PWM0 X3 X7 XB XF Y3 Y7 YB YF PWM3 6 5 4 3 2 1 6 5 4 3 2 1 MRTC Master memory board with real-time clock (supplied) Y04R Relay output unit (11.7) (0.46) Input unit (supplied) Output harness (supplied) × 4 Input unit 210 8.27 50 1.97 55 2.17 Y04R Relay output unit (supplied) × 4 CPU unit (supplied) 115 4.53 CPU unit 184 7.24 XF XC Y3 Y0 Y7 Y4 YB YFP WM3 Y8 YCP WM0 80 3.15 X8 TOOL por XB RS-485 X4 USB X7 S D X0 R D X3 R D S D COM2 port panasonic.net/id/pidsx/global RUN PROG 2012.09 Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department No. CE-GRC-4 September, 2012 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan ■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2012
UGRC1Y04R 价格&库存

很抱歉,暂时无法提供与“UGRC1Y04R”相匹配的价格&库存,您可以联系我们找货

免费人工找货