779507-03 数据手册
Laptop Control of PXI with ExpressCard (ExpressCard MXI) NI PXI-ExpressCard8360, NI ExpressCard-8360, NI PXI-8360 NEW! • • • • Laptop control of PXI/CompactPCI ExpressCard-to-PXI remote control 110 MB/s sustained throughput ExpressCard/34 module, compatible with both ExpressCard/34 and ExpressCard/54 slots • Cabling up to 7 m with rugged screw-in connectors • Ability to use the same PXI module and cable as MXI-Express • Software-transparent link that requires no programming Overview The National Instruments ExpressCard MXI interface kit gives you direct control of PXI systems via your laptop computer. The ExpressCard-to-PXI link is transparent to software applications and drivers, therefore, it provides the ability to use laptop computers to control PXI systems. The NI ExpressCard MXI interface kit is ideal for portable systems such as those used for field tests, and you can pair it with DC-powered chassis to provide mobile solutions for applications such as in-vehicle data logging. Compatibility with MXI-Express The ExpressCard MXI kit uses the same PXI module and cable as the MXI-Express kits (NI PXI-PCIe836x) that provide PCI Express control of PXI from desktop computers, servers, and workstations. Because of this, you can use both your laptop and desktop computers to control the same PXI system without having to replace the PXI controller module or cable. Ordering Information For online configuration of a complete PXI system, including chassis, modules, and all accessories, visit ni.com/pxiadvisor. ExpressCard MXI Kit for PXI/CompactPCI NI PXI-ExpressCard8360 with 3 m cable ..............................779507-03 Kit includes one ExpressCard card (NI ExpressCard-8360), one PXI module (PXI-8360), and one cable. ExpressCard Control of PXI With an ExpressCard MXI link, you can transparently control a PXI system from a laptop computer with either an ExpressCard/34 or ExpressCard/54 slot. The ExpressCard MXI link consists of an NI ExpressCard-8360 card in the laptop computer connected via an ExpressCard MXI cable to an NI PXI-8360 module in slot 1 of a PXI chassis. The NI ExpressCard-8360 card provides a x1 (by one) PCI Express link that is cabled to the PXI-8360 module. The PXI-8360 module includes a bridge that converts the PCI Express link to the PCI bus that is used in PXI. Thus, all PXI modules appear as if they are PCI boards within the computer itself. However, you benefit from the increased number of slots, power and cooling per slot, module selection, and synchronization features provided by PXI. For a list of compatible laptop computers, visit the NI PXI-ExpressCard8360 model page on ni.com/pxi. PXI Interface Module NI PXI-8360............................................................................779501-01 ExpressCard MXI Interface NI ExpressCard-8360 ............................................................779507-01 ExpressCard MXI Cables 3 m ......................................................................................779500-03 7 m ......................................................................................779500-07 BUY NOW! For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/pxi. Laptop Control of PXI with ExpressCard (ExpressCard MXI) Specifications Specifications are subject to change without notice. Power Requirements PXI-8360 Power Rail (V) +3.3 +5 +12 -12 Typical Current 1.500 A 5 mA 5 mA 0 mA Maximum Current 1.750 A 20 mA 20 mA 0 mA NI ExpressCard-8360 Power Rail (V) +3.3 +3.3 (AUX) +1.5 Typical Current (mA) 220 20 0 Maximum Current (mA) 280 30 0 Physical Dimensions PXI-8360............................................................................. NI ExpressCard-8360 ........................................................ Slot requirements PXI-8360............................................................................. NI ExpressCard-8360 ........................................................ Maximum cable length ......................................................... Compatibility ......................................................................... 10.0 by 16.0 cm (3.9 by 6.3 in.) 10.2 by 3.4 cm (4.0 by 1.3 in.) One 3U PXI system controller slot One ExpressCard/34 or ExpressCard/54 slot 7m Fully compatible with the PXI Hardware Specification, Revision 2.1, and the PCMCIA ExpressCard Standard, Revision 1.0 or later Operating Environment PXI-8360 Ambient temperature range.............................................. Operating relative humidity............................................... NI ExpressCard-8360 Ambient temperature range.............................................. Operating relative humidity............................................... 0 to 55 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) 10 to 90%, noncondensing (tested in accordance with IEC-60068-2-56) 0 to 65 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) 5 to 95%, noncondensing (tested in accordance with IEC-60068-2-56) Storage Environment Ambient temperature range .................................................. -20 to 70 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) Storage relative humidity ...................................................... 5 to 95%, noncondensing (tested in accordance with IEC-60068-2-56) Shock Operational shock .................................................................. 30 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27; test profile developed in accordance with MIL-PRF-28800F) Random Vibration Operating ............................................................................... 5 to 500 Hz, 0.3 grms Nonoperating ......................................................................... 5 to 500 Hz, 2.4 grms (tested in accordance with IEC-60068-2-64; nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3) Note: For full EMC compliance, operate this device with shielded cabling. In addition, all covers and filler panels must be installed. Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the certification column. BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.) 2 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. SERVICE NEEDS Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 813 3693 National Instruments • info@ni.com *351347A-01* 351347A-01 2006-6953-501-101-D © 2006 National Instruments Corporation. All rights reserved. MXI, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
779507-03
1. 物料型号: - NI PXI-ExpressCard8360:带有3米线缆的ExpressCard MXI套件,型号为779507-03。 - NI PXI-8360:PXI接口模块。 - NI ExpressCard-8360:ExpressCard MXI接口。

2. 器件简介: - 该文档介绍了一种通过ExpressCard实现笔记本电脑对PXI系统的直接控制的接口套件。该套件适用于便携式系统,如现场测试和车载数据记录等移动解决方案。

3. 引脚分配: - NI ExpressCard-8360卡提供一条x1的PCI Express链路,通过线缆连接到PXI-8360模块。

4. 参数特性: - PXI-8360模块包括一个桥接器,将PCI Express链路转换为PXI中使用的PCI总线。 - 电源要求:PXI-8360模块和NI ExpressCard-8360的电源轨和典型/最大电流值。

5. 功能详解: - ExpressCard MXI链接允许从带有ExpressCard/34或ExpressCard/54插槽的笔记本电脑透明地控制PXI系统。 - 与MXI-Express套件兼容,可以使用相同的PXI模块和线缆从桌面计算机、服务器和工作站控制PXI。

6. 应用信息: - 适用于需要便携式解决方案的现场测试和车载数据记录等应用。

7. 封装信息: - PXI-8360的尺寸为10.0 x 16.0厘米(3.9 x 6.3英寸)。 - NI ExpressCard-8360的尺寸为10.2 x 3.4厘米(4.0 x 1.3英寸)。 - 支持的最大电缆长度为7米。
779507-03 价格&库存