PXIe-SMU5100 Bundle
Expandable PXI bundle based on PXIe-4139 SMU,
±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA
Specifications
PXIe-1083 and PXIe-4139 (20 W DC)
PXI SMU Bundle
In the Box
PXIe-SMU5100 Bundle
Bundle P/N: 867110-01
Accessories:
• Thunderbolt cable
• Power cable, US
PXIe-4139
(SMU)
PXIe-1083
(5-Slot PXIe Chassis)
Recommended Software
Test Workflow
P/N: 788509-35
Test Workflow is a bundle of select NI software featuring
engineering-specific tools that help test professionals
accomplish anything from their day-to-day work to
overcoming their most challenging obstacles.
Test Workflow includes:
• LabVIEW - a graphical programming environment
engineers use to develop automated research,
validation, and production test systems.
• InstrumentStudio - an application software that
provides an integrated approach to interactive PXI
measurements.
• TestStand - a test executive software that accelerates
system development and deployment for engineers in
validation and production.
• And more NI Software!
Table of Contents
This document combines the PDFs of this bundle together. The page numbers in the table of
contents correspond to the page number of PDF the component’s documentation begins.
PXIe-1083 Specifications…………………………………………………………………………. 3
PXIe-4139 Specifications…………………………………………………………………………. 16
PXIe-1083
Specifications
PXIe-1083 Specifications
PXIe-1083 Specifications
This document contains specifications for the PXIe-1083 chassis.
Electrical
The following section provides information about the PXIe-1083 AC input and DC
output.
AC Input
Input rating
100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A
Operating voltage range1
90 VAC to 264 VAC
Nominal input frequency
50 Hz/60 Hz
Operating frequency range1 47 Hz to 63 Hz
Efficiency
78% typical
Over-current protection
Internal fuse in line
Main power disconnect
The AC power cable provides main power disconnect. Do not
position the equipment so that it is difficult to disconnect the power
cord. The front-panel power switch causes the internal chassis
power supply to provide DC power to the PXI Express backplane.
Caution Disconnect power cord to completely remove power.
© National Instruments
3
PXIe-1083 Specifications
DC Output
DC output characteristics of the PXIe-1083.
Voltage Rail Maximum Current
Load Regulation
Maximum Ripple and Noise (20 MHz BW)
+5V_AUX
1.0 A
±5%
50 mVpp
+12 V
30.1 A
±5%
120 mVpp
+5 V
25.1 A
±5%
50 mVpp
+3.3 V
30.7 A
±5%
50 mVpp
-12 V
0.75 A
±5%
120 mVpp
Maximum total available power for the PXIe-1083 is 293 W.
The maximum combined power available on +3.3 V and +5 V is 180 W.
The maximum power available for each Thunderbolt port is 15 W (5 V/3 A).
Table 1. Backplane Slot Current Capacity
Slot
+5 V V (I/O) +3.3 V +12 V -12 V 5 VAUX
Hybrid Peripheral Slot with PXI-5 Peripheral
-
-
3A
6A
-
1A
Hybrid Peripheral Slot with PXI-1 Peripheral
6A
5A
6A
1A
1A
-
Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V.
Note The maximum power dissipated in a peripheral slot should not
exceed 58 W. Refer to the Operating Environment section for ambient
temperature considerations at 58 W.
4
Over-current
protection
All outputs are protected from short circuit and overload, they recover
and return to regulation when the overload is removed and the power is
cycled.
Over-voltage
protection
+3.3 V clamped at 3.7 V to 4.3 V, +5 V clamped at 5.7 V to 6.5 V,
+12 V clamped at 13.4 V to 15.6 V
ni.com
PXIe-1083 Specifications
Chassis Cooling
Module cooling
Forced air circulation (positive pressurization) through one 150
CFM fan
Module slot airflow direction Bottom of module to top of module
Module intake
Bottom of chassis
Module exhaust
Top, right side of chassis
Slot cooling capacity
58 W; slot 6 supports 58 W cooling with high fan mode
Power supply cooling
Forced air circulation through integrated fans
Power supply intake
Front and left side chassis
Power supply exhaust
Rear of chassis
Minimum chassis cooling clearances
Above
44.45 mm (1.75 in.)
Rear
44.45 mm (1.75 in.)
Sides
44.45 mm (1.75 in.)
Below
Rack
44.45 mm (1.75 in.)
Desktop
25.4 mm (1.00 in.)
© National Instruments
5
PXIe-1083 Specifications
Environmental
Maximum altitude
2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode)
Pollution Degree
2
Indoor use only.
Operating Environment
Ambient temperature range
When all peripheral modules
require ≤38 W cooling capacity
per slot
0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets
MIL-PRF-28800F Class 3 low temperature limit and high
temperature limit.
When any peripheral module
requires >38 W cooling capacity
per slot
0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets
MIL-PRF-28800F Class 3 low temperature limit and MILPRF-28800F Class 4 high temperature limit.
Relative humidity range
20% to 80%, noncondensing
Storage Environment
Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MILPRF-28800F Class 3 limits.
Relative humidity range
6
ni.com
10% to 95%, noncondensing
PXIe-1083 Specifications
Shock and Vibration
Operational shock
30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MILPRF-28800F Class 2 limits.
Operational random
vibration
5 to 500 Hz, 0.3 grms
Non-operating
vibration
5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile
exceeds the requirements of MIL-PRF-28800F, Class 3.
Acoustic Emissions
Sound Pressure Level (at Operator Position)
(Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
38 W Profile
Auto fan (up to 30 °C ambient)
33.7 dBA
High fan
50.8 dBA
58 W Profile
Auto fan (up to 30 °C ambient)
54.7 dBA
High fan
55.3 dBA
Sound Power Level
38 W Profile
© National Instruments
7
PXIe-1083 Specifications
Auto fan (up to 30 °C ambient)
44.9 dBA
High fan
60.3 dBA
58 W Profile
Auto fan (up to 30 °C ambient)
63.4 dBA
High fan
64.2 dBA
Note The protection provided by the PXIe-1083 can be impaired if it is
used in a manner not described in this document.
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical
equipment safety standards for measurement, control, and laboratory use:
■
■
IEC 61010-1, EN 61010-1
UL 61010-1, CSA C22.2 No. 61010-1
Note For safety certifications, refer to the product label or the Product
Certifications and Declarations section.
EMC Guidelines
This product was tested and complies with the regulatory requirements and limits
for electromagnetic compatibility (EMC) stated in the product specifications. These
requirements and limits provide reasonable protection against harmful interference
when the product is operated in the intended operational electromagnetic
environment.
8
ni.com
PXIe-1083 Specifications
This product is intended for use in industrial locations. However, harmful
interference may occur in some installations, when the product is connected to
a peripheral device or test object, or if the product is used in residential areas. To
minimize interference with radio and television reception and prevent unacceptable
performance degradation, install and use this product in strict accordance with the
instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved
by NI could void your authority to operate it under your local regulatory rules.
EMC Notices
Refer to the following notices for cables, accessories, and prevention measures
necessary to ensure the specified EMC performance.
Notice
For EMC declarations and certifications, and additional information, refer
to the Product Certifications and Declarations section.
Notice Changes or modifications to the product not expressly approved
by NI could void your authority to operate the product under your local
regulatory rules.
Notice Operate this product only with shielded cables and accessories.
Electromagnetic Compatibility Standards
This product meets the requirements of the following EMC standards for electrical
equipment for measurement, control, and laboratory use:
■
■
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
© National Instruments
9
PXIe-1083 Specifications
■
AS/NZS CISPR 11: Group 1, Class A emissions
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or
medical equipment that does not intentionally generate radio frequency
energy for the treatment of material or inspection/analysis purposes.
Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class
A equipment is intended for use in nonresidential locations.
CE Compliance
This product meets the essential requirements of applicable European Directives, as
follows:
■
■
■
2014/35/EU; Low-Voltage Directive (safety)
2014/30/EU; Electromagnetic Compatibility Directive (EMC)
2011/65/EU; Restriction of Hazardous Substances (RoHS)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory
compliance information. To obtain product certifications and the DoC for NI
products, visit ni.com/product-certifications, search by model number, and click
the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally
responsible manner. NI recognizes that eliminating certain hazardous substances
from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy
Planet web page at ni.com/environment. This page contains the environmental
10
ni.com
PXIe-1083 Specifications
regulations and directives with which NI complies, as well as other environmental
information not included in this document.
EU and UK Customers
•
Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life
cycle, all NI products must be disposed of according to local laws and regulations.
For more information about how to recycle NI products in your region, visit ni.com/
environment/weee.
电子信息产品污染控制管理办法(中国 RoHS)
•
中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物
质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/
rohs_china。(For information about China RoHS compliance, go to ni.com/
environment/rohs_china.)
e
5
40
Backplane
Size
3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical
packaging. PXI Express Specification compliant. Accepts both PXI
Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules.
Backplane bare-board
material
UL 94 V-0 Recognized
Backplane connectors
Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated
System Synchronization Clocks
10 MHz System Reference Clock: PXI_CLK10
© National Instruments
11
PXIe-1083 Specifications
Maximum slot-to-slot skew 250 ps
Accuracy
±25 ppm max (guaranteed over the operating temperature range)
Maximum jitter
5 ps RMS phase-jitter (10 Hz–1 MHz range)
Duty-factor
45% to 55%
Unloaded signal swing
3.3 V ±0.3 V
Note For other specifications, refer to the PXI-1 Hardware Specification.
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew
100 ps
Accuracy
±25 ppm max (guaranteed over the operating
temperature range)
Maximum jitter
3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps
RMS phase-jitter (12 kHz to 20 MHz range)
Duty-factor for PXIe_CLK100
45% to 55%
Absolute differential voltage (When
terminated with a 50 Ω load to 1.30 V or
Thévenin equivalent)
400 mV to 1000 mV
Note For other specifications, refer to the PXI-5 PXI Express Hardware
Specification.
12
ni.com
PXIe-1083 Specifications
Mechanical
Standard chassis dimensions
Height
177.1 mm (6.97 in.)
Width
257.1 mm (10.12 in.)
Depth
214.2 mm (8.43 in.)
Weight
6.7 kg (14.8 lb)
Chassis materials Extruded Aluminum (6063-T5, 6060-T6), Cold Rolled Steel/Stainless Steel,
Santoprene, Urethane Foam, PC-ABS, Nylon, Polyethylene
Finish
Conductive Clear Iridite on Aluminum, Electroplated Nickel on Cold Rolled
Steel, Electroplated Zinc on Cold Rolled Steel
The following figures show the PXIe-1083 chassis dimensions. The holes shown are
for installing the optional rack mount kits.
Figure 1. PXIe-1083 Chassis Dimensions (Front)
257.1 mm (10.12 in.)
177.1 mm
(6.97 in.)
PXIe-1083
25.4 mm
(1 in.)
© National Instruments
13
PXIe-1083 Specifications
Figure 2. PXIe-1083 Chassis Dimensions (Side)
164.2 mm (6.46 in.)
43.7 mm
(1.72 in.)
76.7 mm
(3.02 in.)
113.6 mm
(4.47 in.)
79.4 mm
(3.13 in.)
46.4 mm
(1.83 in.)
26 mm (1.02 in.)
214.2 mm (8.43 in.)
Figure 3. PXIe-1083 Chassis Dimensions (Bottom)
169.0 mm
(6.65 in.)
27.6 mm
(1.09 in.)
17.5 mm (0.69 in.)
222.0 mm (8.74 in.)
1 The operating range is guaranteed by design.
2 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use.
3 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use.
14
ni.com
© 2022 National Instruments Corporation.
PXIe-4139
Specifications
PXIe-4139 Specifications
PXIe-4139 Specifications
These specifications apply to the PXIe-4139.
Note In this document, the PXIe-4139 (40W) and PXIe-4139 (20W) are
referred to inclusively as the PXIe-4139. The information in this document
applies to all versions of the PXIe-4139 unless otherwise specified. To
determine which version of the module you have, locate the device name
in one of the following places:
In MAX—The PXIe-4139 (40W) shows NI PXIe-4139 (40W), and the
PXIe-4139 (20W) shows as NI PXIe-4139.
■
Device front panel—The PXIe-4139 (40W) shows PXIe-4139 40W
System SMU, and the PXIe-4139 (20W) shows NI PXIe-4139 Precision
System SMU on the front panel.
■
Definitions
Warranted specifications describe the performance of a model under stated
operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under
stated operating conditions but are not covered by the model warranty.
Typical specifications describe the performance met by a majority of
models.
Nominal specifications describe an attribute that is based on design,
conformance testing, or supplemental testing.
Measured specifications describe the measured performance of a
representative model.
■
■
■
Specifications are Warranted unless otherwise noted.
© National Instruments
3
PXIe-4139 Specifications
Conditions
Specifications are valid under the following conditions unless otherwise noted.
■
■
Ambient temperature[1] of 23 °C ± 5 ºC
Chassis with slot cooling capacity ≥38 W[2]
■
■
■
■
■
For chassis with slot cooling capacity = 38 W, fan speed set to HIGH
Calibration interval of 1 year
30 minutes warm-up time
Self-calibration performed within the last 24 hours
NI-DCPower Aperture Time is set to 2 power-line cycles (PLC)
Cleaning Statement
Notice Clean the hardware with a soft, nonmetallic brush. Make sure
that the hardware is completely dry and free from contaminants before
returning it to service.
Device Capabilities
The following table and figures illustrate the voltage and the current source and sink
ranges of the PXIe-4139.
Table 1. Current Source and Sink Ranges
DC voltage ranges
4
DC current source and sink ranges
■
600 mV
■
1 μA
■
6V
■
10 μA
■
60 V [3]
■
100 μA
■
1 mA
■
10 mA
■
100 mA
ni.com
PXIe-4139 Specifications
DC voltage ranges
DC current source and sink ranges
1A
■
■
3A
■
10 A, pulse only
Current (A)
Figure 1. Quadrant Diagram for PXIe-4139 (40W)
11
10
–50 V, 10 A
9
8
7
6
Quadrant II
5
4
–13.3 V, 3 A
3
–40 W
2
1 –60 V, 0.66 A
0
–1
–60 V, –0.66 A
–2
40 W
–3
–13.3 V, –3 A
–4
–5
Quadrant III
–6
–7
–8
–9
–50 V, –10 A
–10
–11
–60
–50
–40
–30
–20
–10
50 V, 10 A
Quadrant I
13.3V, 3 A
40 W
60 V, 0.66 A
60 V, –0.66 A
–40 W
13.3 V, –3 A
Quadrant IV
50 V, –10 A
0
10
Voltage (V)
20
30
40
50
60
Pulse or DC, up to 40 W
Pulse only, up to 500 W
For additional information related to the Pulse Voltage or Pulse Current settings
of the Output Function, for the PXIe-4139 (40W), including pulse on time and duty
cycle limits for a particular operating point, refer to Pulsed Operation.
For supplementary examples, refer to Examples of Determining Extended Range
Pulse Parameters and Optimizing Slew Rate using NI SourceAdapt.
© National Instruments
5
PXIe-4139 Specifications
Current (A)
Figure 2. Quadrant Diagram for PXIe-4139 (20W)
11
10
–50 V, 10 A
–20 V, 10 A
20 V, 10 A
50 V, 10 A
9
8
–200 W
200 W
7
6
Quadrant I
Quadrant II
5
4
–4 V, 3 A
6.6 V, 3 A
–50 V, 4 A
50 V, 4 A
3
–12 W
20 W
2
1 –60 V, 0.2 A
60 V, 0.33 A
0
60 V, –0.2 A
–1 –60 V, –0.33 A
–2
–12 W
20 W
–3
–6.6 V, –3 A
4 V, –3 A
–50 V, –4 A
50 V, –4 A
–4
–5
Quadrant IV
Quadrant III
–6
–7
–200 W
200 W
–8
–9
–20 V, –10 A
20 V, –10 A
–50 V, –10 A
50 V, –10 A
–10
–11
–60
–50
–40
–30
–20
–10
0
10
20
30
40
50
60
Voltage (V)
Pulse or DC
Pulse only, 1ms, 5% duty cycle
Pulse only, 400 µs, 2% duty cycle
DC sourcing power and sinking power are limited to the values in the following
table, regardless of output voltage.[4]
Table 2. DC Sourcing & Sinking Power
Model Variant
Chassis Type
DC Sourcing Power
DC Sinking Power
PXIe-4139 (40W)
≥58 W Slot Cooling Capacity
40 W
40 W