    PXIE-4139 SMU BUNDLE, 60 V, 3 A

  • 数据手册
  • 价格&库存
867110-01 数据手册
PXIe-SMU5100 Bundle Expandable PXI bundle based on PXIe-4139 SMU, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Specifications PXIe-1083 and PXIe-4139 (20 W DC) PXI SMU Bundle In the Box PXIe-SMU5100 Bundle Bundle P/N: 867110-01 Accessories: • Thunderbolt cable • Power cable, US PXIe-4139 (SMU) PXIe-1083 (5-Slot PXIe Chassis) Recommended Software Test Workflow P/N: 788509-35 Test Workflow is a bundle of select NI software featuring engineering-specific tools that help test professionals accomplish anything from their day-to-day work to overcoming their most challenging obstacles. Test Workflow includes: • LabVIEW - a graphical programming environment engineers use to develop automated research, validation, and production test systems. • InstrumentStudio - an application software that provides an integrated approach to interactive PXI measurements. • TestStand - a test executive software that accelerates system development and deployment for engineers in validation and production. • And more NI Software! Table of Contents This document combines the PDFs of this bundle together. The page numbers in the table of contents correspond to the page number of PDF the component’s documentation begins. PXIe-1083 Specifications…………………………………………………………………………. 3 PXIe-4139 Specifications…………………………………………………………………………. 16 PXIe-1083 Specifications PXIe-1083 Specifications PXIe-1083 Specifications This document contains specifications for the PXIe-1083 chassis. Electrical The following section provides information about the PXIe-1083 AC input and DC output. AC Input Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range1 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz Operating frequency range1 47 Hz to 63 Hz Efficiency 78% typical Over-current protection Internal fuse in line Main power disconnect The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. Caution Disconnect power cord to completely remove power. © National Instruments 3 PXIe-1083 Specifications DC Output DC output characteristics of the PXIe-1083. Voltage Rail Maximum Current Load Regulation Maximum Ripple and Noise (20 MHz BW) +5V_AUX 1.0 A ±5% 50 mVpp +12 V 30.1 A ±5% 120 mVpp +5 V 25.1 A ±5% 50 mVpp +3.3 V 30.7 A ±5% 50 mVpp -12 V 0.75 A ±5% 120 mVpp Maximum total available power for the PXIe-1083 is 293 W. The maximum combined power available on +3.3 V and +5 V is 180 W. The maximum power available for each Thunderbolt port is 15 W (5 V/3 A). Table 1. Backplane Slot Current Capacity Slot +5 V V (I/O) +3.3 V +12 V -12 V 5 VAUX Hybrid Peripheral Slot with PXI-5 Peripheral - - 3A 6A - 1A Hybrid Peripheral Slot with PXI-1 Peripheral 6A 5A 6A 1A 1A - Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V. Note The maximum power dissipated in a peripheral slot should not exceed 58 W. Refer to the Operating Environment section for ambient temperature considerations at 58 W. 4 Over-current protection All outputs are protected from short circuit and overload, they recover and return to regulation when the overload is removed and the power is cycled. Over-voltage protection +3.3 V clamped at 3.7 V to 4.3 V, +5 V clamped at 5.7 V to 6.5 V, +12 V clamped at 13.4 V to 15.6 V ni.com PXIe-1083 Specifications Chassis Cooling Module cooling Forced air circulation (positive pressurization) through one 150 CFM fan Module slot airflow direction Bottom of module to top of module Module intake Bottom of chassis Module exhaust Top, right side of chassis Slot cooling capacity 58 W; slot 6 supports 58 W cooling with high fan mode Power supply cooling Forced air circulation through integrated fans Power supply intake Front and left side chassis Power supply exhaust Rear of chassis Minimum chassis cooling clearances Above 44.45 mm (1.75 in.) Rear 44.45 mm (1.75 in.) Sides 44.45 mm (1.75 in.) Below Rack 44.45 mm (1.75 in.) Desktop 25.4 mm (1.00 in.) © National Instruments 5 PXIe-1083 Specifications Environmental Maximum altitude 2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range When all peripheral modules require ≤38 W cooling capacity per slot 0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit. When any peripheral module requires >38 W cooling capacity per slot 0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and MILPRF-28800F Class 4 high temperature limit. Relative humidity range 20% to 80%, noncondensing Storage Environment Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MILPRF-28800F Class 3 limits. Relative humidity range 6 ni.com 10% to 95%, noncondensing PXIe-1083 Specifications Shock and Vibration Operational shock 30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MILPRF-28800F Class 2 limits. Operational random vibration 5 to 500 Hz, 0.3 grms Non-operating vibration 5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.) 38 W Profile Auto fan (up to 30 °C ambient) 33.7 dBA High fan 50.8 dBA 58 W Profile Auto fan (up to 30 °C ambient) 54.7 dBA High fan 55.3 dBA Sound Power Level 38 W Profile © National Instruments 7 PXIe-1083 Specifications Auto fan (up to 30 °C ambient) 44.9 dBA High fan 60.3 dBA 58 W Profile Auto fan (up to 30 °C ambient) 63.4 dBA High fan 64.2 dBA Note The protection provided by the PXIe-1083 can be impaired if it is used in a manner not described in this document. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ ■ IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. 8 ni.com PXIe-1083 Specifications This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions © National Instruments 9 PXIe-1083 Specifications ■ AS/NZS CISPR 11: Group 1, Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class A equipment is intended for use in nonresidential locations. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: ■ ■ ■ 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) 2011/65/EU; Restriction of Hazardous Substances (RoHS) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental 10 ni.com PXIe-1083 Specifications regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers • Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 RoHS) • 中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) e 5 40 Backplane Size 3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks 10 MHz System Reference Clock: PXI_CLK10 © National Instruments 11 PXIe-1083 Specifications Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 5 ps RMS phase-jitter (10 Hz–1 MHz range) Duty-factor 45% to 55% Unloaded signal swing 3.3 V ±0.3 V Note For other specifications, refer to the PXI-1 Hardware Specification. 100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100 Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) Duty-factor for PXIe_CLK100 45% to 55% Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 mV to 1000 mV Note For other specifications, refer to the PXI-5 PXI Express Hardware Specification. 12 ni.com PXIe-1083 Specifications Mechanical Standard chassis dimensions Height 177.1 mm (6.97 in.) Width 257.1 mm (10.12 in.) Depth 214.2 mm (8.43 in.) Weight 6.7 kg (14.8 lb) Chassis materials Extruded Aluminum (6063-T5, 6060-T6), Cold Rolled Steel/Stainless Steel, Santoprene, Urethane Foam, PC-ABS, Nylon, Polyethylene Finish Conductive Clear Iridite on Aluminum, Electroplated Nickel on Cold Rolled Steel, Electroplated Zinc on Cold Rolled Steel The following figures show the PXIe-1083 chassis dimensions. The holes shown are for installing the optional rack mount kits. Figure 1. PXIe-1083 Chassis Dimensions (Front) 257.1 mm (10.12 in.) 177.1 mm (6.97 in.) PXIe-1083 25.4 mm (1 in.) © National Instruments 13 PXIe-1083 Specifications Figure 2. PXIe-1083 Chassis Dimensions (Side) 164.2 mm (6.46 in.) 43.7 mm (1.72 in.) 76.7 mm (3.02 in.) 113.6 mm (4.47 in.) 79.4 mm (3.13 in.) 46.4 mm (1.83 in.) 26 mm (1.02 in.) 214.2 mm (8.43 in.) Figure 3. PXIe-1083 Chassis Dimensions (Bottom) 169.0 mm (6.65 in.) 27.6 mm (1.09 in.) 17.5 mm (0.69 in.) 222.0 mm (8.74 in.) 1 The operating range is guaranteed by design. 2 This product meets the requirements of the environmental standards for electrical equipment for measurement, control, and laboratory use. 3 This product meets the requirements of the environmental standards for electrical equipment for measurement, control, and laboratory use. 14 ni.com © 2022 National Instruments Corporation. PXIe-4139 Specifications PXIe-4139 Specifications PXIe-4139 Specifications These specifications apply to the PXIe-4139. Note In this document, the PXIe-4139 (40W) and PXIe-4139 (20W) are referred to inclusively as the PXIe-4139. The information in this document applies to all versions of the PXIe-4139 unless otherwise specified. To determine which version of the module you have, locate the device name in one of the following places: In MAX—The PXIe-4139 (40W) shows NI PXIe-4139 (40W), and the PXIe-4139 (20W) shows as NI PXIe-4139. ■ Device front panel—The PXIe-4139 (40W) shows PXIe-4139 40W System SMU, and the PXIe-4139 (20W) shows NI PXIe-4139 Precision System SMU on the front panel. ■ Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty. Typical specifications describe the performance met by a majority of models. Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing. Measured specifications describe the measured performance of a representative model. ■ ■ ■ Specifications are Warranted unless otherwise noted. © National Instruments 3 PXIe-4139 Specifications Conditions Specifications are valid under the following conditions unless otherwise noted. ■ ■ Ambient temperature[1] of 23 °C ± 5 ºC Chassis with slot cooling capacity ≥38 W[2] ■ ■ ■ ■ ■ For chassis with slot cooling capacity = 38 W, fan speed set to HIGH Calibration interval of 1 year 30 minutes warm-up time Self-calibration performed within the last 24 hours NI-DCPower Aperture Time is set to 2 power-line cycles (PLC) Cleaning Statement Notice Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. Device Capabilities The following table and figures illustrate the voltage and the current source and sink ranges of the PXIe-4139. Table 1. Current Source and Sink Ranges DC voltage ranges 4 DC current source and sink ranges ■ 600 mV ■ 1 μA ■ 6V ■ 10 μA ■ 60 V [3] ■ 100 μA ■ 1 mA ■ 10 mA ■ 100 mA ni.com PXIe-4139 Specifications DC voltage ranges DC current source and sink ranges 1A ■ ■ 3A ■ 10 A, pulse only Current (A) Figure 1. Quadrant Diagram for PXIe-4139 (40W) 11 10 –50 V, 10 A 9 8 7 6 Quadrant II 5 4 –13.3 V, 3 A 3 –40 W 2 1 –60 V, 0.66 A 0 –1 –60 V, –0.66 A –2 40 W –3 –13.3 V, –3 A –4 –5 Quadrant III –6 –7 –8 –9 –50 V, –10 A –10 –11 –60 –50 –40 –30 –20 –10 50 V, 10 A Quadrant I 13.3V, 3 A 40 W 60 V, 0.66 A 60 V, –0.66 A –40 W 13.3 V, –3 A Quadrant IV 50 V, –10 A 0 10 Voltage (V) 20 30 40 50 60 Pulse or DC, up to 40 W Pulse only, up to 500 W For additional information related to the Pulse Voltage or Pulse Current settings of the Output Function, for the PXIe-4139 (40W), including pulse on time and duty cycle limits for a particular operating point, refer to Pulsed Operation. For supplementary examples, refer to Examples of Determining Extended Range Pulse Parameters and Optimizing Slew Rate using NI SourceAdapt. © National Instruments 5 PXIe-4139 Specifications Current (A) Figure 2. Quadrant Diagram for PXIe-4139 (20W) 11 10 –50 V, 10 A –20 V, 10 A 20 V, 10 A 50 V, 10 A 9 8 –200 W 200 W 7 6 Quadrant I Quadrant II 5 4 –4 V, 3 A 6.6 V, 3 A –50 V, 4 A 50 V, 4 A 3 –12 W 20 W 2 1 –60 V, 0.2 A 60 V, 0.33 A 0 60 V, –0.2 A –1 –60 V, –0.33 A –2 –12 W 20 W –3 –6.6 V, –3 A 4 V, –3 A –50 V, –4 A 50 V, –4 A –4 –5 Quadrant IV Quadrant III –6 –7 –200 W 200 W –8 –9 –20 V, –10 A 20 V, –10 A –50 V, –10 A 50 V, –10 A –10 –11 –60 –50 –40 –30 –20 –10 0 10 20 30 40 50 60 Voltage (V) Pulse or DC Pulse only, 1ms, 5% duty cycle Pulse only, 400 µs, 2% duty cycle DC sourcing power and sinking power are limited to the values in the following table, regardless of output voltage.[4] Table 2. DC Sourcing & Sinking Power Model Variant Chassis Type DC Sourcing Power DC Sinking Power PXIe-4139 (40W) ≥58 W Slot Cooling Capacity 40 W 40 W
867110-01 价格&库存

很抱歉,暂时无法提供与“867110-01”相匹配的价格&库存,您可以联系我们找货

免费人工找货