0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIPCI-6519

NIPCI-6519

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIPCI-6519 - Low-Cost Industrial Digital I/O-30 V, Bank Isolated - National Instruments Corporation

  • 数据手册
  • 价格&库存
NIPCI-6519 数据手册
Low-Cost Industrial Digital I/O – 30 V, Bank Isolated NI 651x • 32- or 64-bank optically isolated inputs and outputs (±30 VDC) • High-reliability industrial feature set – isolation, programmable power-up states, digital I/O watchdogs, change detection, programmable input filters • Low-cost solution with superior features for data acquisition, manufacturing test, and industrial control applications • Direct connection to industrial sensors and actuators • NI-DAQmx software for highest productivity and performance Operating Systems • Windows Vista (32- and 64-bit)/XP/2000 • LabVIEW Real-Time Recommended Software • LabVIEW • LabWindows™/CVI • Measurement Studio Other Compatible Software • ANSI C, C++ • Microsoft Visual Studio .NET 2003 Measurement Services Software (included) • NI-DAQmx Product NI 6510 NI 6511 NI 6512 NI 6513 NI 6514 NI 6515 NI 6516 NI 6517 NI 6518 NI 6519 Bus PCI PCI, PXI PCI, PXI PCI, PXI PCI, PXI PCI, PXI PCI PCI PCI PCI Input Lines 32 source/sink 64 source/sink – – 32 source/sink 32 source/sink – – 16 source/sink 16 source/sink Output Lines – – 64 source 64 sink 32 source 32 sink 32 source 32 sink 16 source 16 sink Isolation Bank Bank Bank Bank Bank Bank Bank Bank Bank Bank Max Range (VDC) ±30 ±30 ±30 ±30 ±30 ±30 ±30 ±30 ±30 ±30 Low Thresh (VDC) ±4 ±4 – – ±4 ±4 – – ±4 ±4 High Thresh (VDC) ±11 ±11 – – ±11 ±11 – – ±11 ±11 Output Current (mA)1 Industrial Feature Set – 3 – 3 350 (75) 3 500 (120) 3 350 (75) 3 500 (120) 3 350 (75) 3 500 (120) 3 350 (75) 3 500 (120) 3 1When using all lines at a 100 percent duty cycle, the maximum drive current for NI 6512 and NI 6514 devices is 75 mA, and 120 mA for NI 6513 and NI 6515 devices. When using only one output line in each bank at a 100 percent duty cycle, the maximum drive current for NI 6512 and NI 6514 devices is 350 mA, and 500 mA for NI 6513 and NI 6515 devices. Table 1. NI 651x Selection Guide Overview and Applications NI 651x devices are industrial 32- or 64-channel isolated digital I/O interfaces for PCI and PXI/CompactPCI systems. You can wire each input bank in a source or sink configuration and input and output at digital levels up to ±30 VDC with high current switching capability. NI 651x devices are ideal for general-purpose data acquisition applications as well as industrial control and automated manufacturing test. With high current drive and isolation, you can connect the digital I/O directly to a wide array of 24 V electronic devices, sensors, and actuators. NI 651x devices offer superior features and high value for industrial control and manufacturing test applications such as factory automation, embedded machine control, and production line verification. These devices have been designed to incorporate the latest hardware technologies and provide innovative features for applications requiring ease of use, high reliability, and performance. NI 651x devices take advantage of NI-DAQmx software, which includes technology to speed up application development with many helpful features including the DAQ Assistant, automatic code generation, and high-performance multithreaded streaming technology. Hardware High-Reliability Industrial Feature Set NI 651x devices offer a set of high-reliability features designed to automate even the most demanding applications: • Isolation provides an extended voltage range and direct connection to industrial sensors and actuators • Programmable power-up states offer safe operation when connected to pumps/valves/motors/relays • Digital I/O watchdogs detect computer or application errors and ensure safe recovery • Change detection triggers your application and returns I/O data after a digital event with minimal processor usage • Programmable input filters eliminate glitches/spikes and remove noise Low-Cost Industrial Digital I/O – 30 V, Bank Isolated Connect Sensors Directly with Isolation Isolation is a form of built-in signal conditioning that provides several advantages, such as an extended voltage range and direct connection to industrial sensors and actuators. Isolation also improves signal quality and protects computer circuitry. It physically and electrically separates two parts of a circuit, which breaks ground loops, improves common-mode voltage and noise rejection, and permits the two parts of the circuit to be at different voltage levels. Many industrial applications require isolation to protect the electronics from transient voltage spikes and provide greater common-mode noise rejection in electrically noisy environments containing machinery and inductive loads. In bank-to-bank isolated devices, such as an NI 651x, each bank (or group) of several channels shares the same ground but is isolated from other banks. Oscillator Voltage Voltage 100-Pin SCSI I/O Connector CPLD Glitch-Free Startup with Programmable Power-Up States With programmable power-up states, you can configure the initial output states of the digital I/O device in software to ensure glitch-free operations when connected to industrial actuators such as pumps, valves, motors, and relays. The digital I/O device holds these I/O states after receiving power, so your computer can boot and your software application can begin running. Programmable power-up states are glitch-free, meaning the outputs never go through an incorrect state during power up. You can configure each digital line as high-output or low-output. The digital I/O device stores the settings in onboard nonvolatile memory and implements the power-up states automatically after power is applied to the device. Detect and Recover with Digital I/O Watchdogs NI digital I/O watchdogs provide protection against a wide variety of fault conditions: • Computer crash – total OS crash • Application crash – software application ceases to respond • Driver crash – device driver ceases to respond • PCI bus failure – communications cease to respond Darlington Arrays Photocouplers FPGA Photocouplers MiniMITE 1 Flash Figure 1. NI 651x Hardware Block Diagram Bus Switch PCI/PXI Bus P0.0 P0.2 P0.4 P0.6 COM P1.1 P1.3 P1.5 P1.7 P2.0 P2.2 P2.4 P2.6 COM P3.1 P3.3 P3.5 P3.7 COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 P0.1 P0.3 P0.5 P0.7 P1.0 P1.2 P1.4 P1.6 COM P2.1 P2.3 P2.5 P2.7 P3.0 P3.2 P3.4 P3.6 COM P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P0.COM P0.COM P0.COM P0.COM P2.0 P2.1 P2.2 P2.3 P2.4 P2.5 P2.6 P2.7 P2.COM P2.COM P2.COM P2.COM NC P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 P4.COM P4.COM P4.COM P4.COM P6.0 P6.1 P6.2 P6.3 P6.4 P6.5 P6.6 P6.7 P6.COM P6.COM P6.COM P6.COM NC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 P1.COM P1.COM P1.COM P1.COM P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 P3.COM P3.COM P3.COM P3.COM NC P5.0 P5.1 P5.2 P5.3 P5.4 P5.5 P5.6 P5.7 P5.COM P5.COM P5.COM P5.COM P7.0 P7.1 P7.2 P7.3 P7.4 P7.5 P7.6 P7.7 P7.COM P7.COM P7.COM P7.COM NC P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P0.COM (P0.GND) P0.VCC P0.VCC P0.VCC P2.0 P2.1 P2.2 P2.3 P2.4 P2.5 P2.6 P2.7 P2.COM (P2.GND) P2.VCC P2.VCC P2.VCC NC P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 P4.COM (P4.GND) P4.VCC P4.VCC P4.VCC P6.0 P6.1 P6.2 P6.3 P6.4 P6.5 P6.6 P6.7 P6.COM (P6.GND) P6.VCC P6.VCC P6.VCC P6.+5V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 P1.COM (P1.GND) P1.VCC P1.VCC P1.VCC P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 P3.COM (P3.GND) P3.VCC P3.VCC P3.VCC NC P5.0 P5.1 P5.2 P5.3 P5.4 P5.5 P5.6 P5.7 P5.COM (P5.GND) P5.VCC P5.VCC P5.VCC P7.0 P7.1 P7.2 P7.3 P7.4 P7.5 P7.6 P7.7 P7.COM (P7.GND) P7.VCC P7.VCC P7.VCC P7.+5V P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P0.COM (P0.VCC) P0.GND P0.GND P0.GND P2.0 P2.1 P2.2 P2.3 P2.4 P2.5 P2.6 P2.7 P2.COM (P2.VCC) P2.GND P2.GND P2.GND NC P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 P4.COM (P4.VCC) P4.GND P4.GND P4.GND P6.0 P6.1 P6.2 P6.3 P6.4 P6.5 P6.6 P6.7 P6.COM (P6.VCC) P6.GND P6.GND P6.GND P6.+5V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 P1.COM (P1.VCC) P1.GND P1.GND P1.GND P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 P3.COM (P3.VCC) P3.GND P3.GND P3.GND NC P5.0 P5.1 P5.2 P5.3 P5.4 P5.5 P5.6 P5.7 P5.COM (P5.VCC) P5.GND P5.GND P5.GND P7.0 P7.1 P7.2 P7.3 P7.4 P7.5 P7.6 P7.7 P7.COM (P7.VCC) P7.GND P7.GND P7.GND P7.+5V P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P0.COM P0.COM P0.COM P0.COM P2.0 P2.1 P2.2 P2.3 P2.4 P2.5 P2.6 P2.7 P2.COM P2.COM P2.COM P2.COM NC P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 P4.COM (P4.GND) P4.VCC P4.VCC P4.VCC P6.0 P6.1 P6.2 P6.3 P6.4 P6.5 P6.6 P6.7 P6.COM (P6.GND) P6.VCC P6.VCC P6.VCC P6.+5V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 P1.COM P1.COM P1.COM P1.COM P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 P3.COM P3.COM P3.COM P3.COM NC P5.0 P5.1 P5.2 P5.3 P5.4 P5.5 P5.6 P5.7 P5.COM (P5.GND) P5.VCC P5.VCC P5.VCC P7.0 P7.1 P7.2 P7.3 P7.4 P7.5 P7.6 P7.7 P7.COM (P7.GND) P7.VCC P7.VCC P7.VCC P7.+5V NI 6510 NI 6511 NI 6512 NI 6513 NI 6514 Figure 2. NI 6510, NI 6511, NI 6512, NI 6513, and NI 6514 Connectors BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 2 Low-Cost Industrial Digital I/O – 30 V, Bank Isolated P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P0.COM P0.COM P0.COM P0.COM P2.0 P2.1 P2.2 P2.3 P2.4 P2.5 P2.6 P2.7 P2.COM P2.COM P2.COM P2.COM NC P4.0 P4.1 P4.2 P4.3 P4.4 P4.5 P4.6 P4.7 P4.COM (P4.VCC) P4.GND P4.GND P4.GND P6.0 P6.1 P6.2 P6.3 P6.4 P6.5 P6.6 P6.7 P6.COM (P6.VCC) P6.GND P6.GND P6.GND P6.+5V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 P1.COM P1.COM P1.COM P1.COM P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 P3.COM P3.COM P3.COM P3.COM NC P5.0 P5.1 P5.2 P5.3 P5.4 P5.5 P5.6 P5.7 P5.COM (P5.VCC) P5.GND P5.GND P5.GND P7.0 P7.1 P7.2 P7.3 P7.4 P7.5 P7.6 P7.7 P7.COM (P7.VCC) P7.GND P7.GND P7.GND P7.+5V P0.0 P0.2 P0.4 P0.6 VCC P1.1 P1.3 P1.5 P1.7 P2.0 P2.2 P2.4 P2.6 VCC P3.1 P3.3 P3.5 P3.7 COM (GND) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 P0.1 P0.3 P0.5 P0.7 P1.0 P1.2 P1.4 P1.6 VCC P2.1 P2.3 P2.5 P2.7 P3.0 P3.2 P3.4 P3.6 VCC P0.0 P0.2 P0.4 P0.6 GND P1.1 P1.3 P1.5 P1.7 P2.0 P2.2 P2.4 P2.6 GND P3.1 P3.3 P3.5 P3.7 COM (VCC) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 P0.1 P0.3 P0.5 P0.7 P1.0 P1.2 P1.4 P1.6 GND P2.1 P2.3 P2.5 P2.7 P3.0 P3.2 P3.4 P3.6 GND P0.0 P0.2 P0.4 P0.6 P1.0 P1.2 P1.4 P1.6 IN.COM VCC P2.0 P2.2 P2.4 P2.6 P3.0 P3.2 P3.4 P3.6 OUT.COM (GND) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 P0.1 P0.3 P0.5 P0.7 P1.1 P1.3 P1.5 P1.7 VCC VCC P2.1 P2.3 P2.5 P2.7 P3.1 P3.3 P3.5 P3.7 P0.0 P0.2 P0.4 P0.6 P1.0 P1.2 P1.4 P1.6 IN.COM GND P2.0 P2.2 P2.4 P2.6 P3.0 P3.2 P3.4 P3.6 OUT.COM (VCC) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 P0.1 P0.3 P0.5 P0.7 P1.1 P1.3 P1.5 P1.7 GND GND P2.1 P2.3 P2.5 P2.7 P3.1 P3.3 P3.5 P3.7 NI 6515 NI 6516 NI 6517 NI 6518 NI 6519 Figure 3. NI 6515, NI 6516, NI 6517, NI 6518, and NI 6519 SCSI I/O Connectors With watchdogs, the digital outputs go to a safe recovery state when a fault condition is detected and the watchdog timer expires. Watchdogs are important whenever the device is connected to actuators such as pumps, valves, motors, and relays. The digital I/O device monitors the software application, and if the application fails to respond within the time limit, the device automatically sets the output lines to a user-defined safe state. The device remains in the watchdog state until the watchdog timer is disarmed by the application and new I/O values are written, the NI 651x is reset, or the computer is restarted. independently of other data acquisition activities such as analog input or output events. Eliminate Noise with Programmable Input Filters Programmable input filters remove noise, glitches, and spikes on inputs and provide debouncing for digital switches and relays. This feature is important for applications in noisy industrial environments to prevent false readings caused by noise. You can configure the programmable input filter for each digital line by setting the filter time in seconds. Any digital noise, glitch, or spike that is shorter than half of the specified filter time is blocked by the digital I/O device, preventing invalid readings and false triggers for change detection events. Trigger Your Application with Change Detection With change detection, you can automatically trigger your software application to perform a digital read operation upon a digital change of state. A digital change of state is defined as the rising edge (0 to 1 transition) or falling edge (1 to 0 transition) on one or more digital lines. With change detection, you can monitor digital events with minimal processor usage. No polling is necessary because the digital I/O device generates an interrupt to automatically wake up your application. Using NI-DAQmx software technology, an NI 651x notifies the software application when the event is detected, causing the application to automatically perform a read operation. To minimize the effects of noisy input lines, you can use programmable input filters in combination with change detection to eliminate spurious change detection events caused by noise or glitches. NI-DAQmx also includes multithreaded streaming technology so digital change detection events can occur Figure 4. Write Your Application with No Programming Using the NI DAQ Assistant BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 3 Low-Cost Industrial Digital I/O – 30 V, Bank Isolated • Use automatic timing, triggering, and synchronization technology to make advanced applications easy • Visit ni.com for more than 3,000 free software downloads to jump-start your project • Use the NI-DAQmx functions for jumper-free software configuration of all digital I/O features without hardware switches/jumpers • Develop your application with easy and open programming in LabVIEW, ANSI C, Microsoft Visual C++, C#, and Visual Basic .NET NI-DAQmx Software Technology NI 651x devices require NI-DAQmx 7.1 or later (7.2 for NI 6511, NI 6512, and NI 6513; 7.3 for NI 6510, NI 6516, NI 6517, NI 6518, and NI 6519). NI-DAQmx measurement services software, included free with the purchase of an NI 651x device, is available for download from ni.com/downloads. With NI-DAQmx, you can program your NI digital I/O device in LabVIEW, ANSI C, Microsoft Visual C++, and the Microsoft .NET languages C# and Visual Basic .NET. You can access the full functionality and state-of-theart hardware technology of your NI 651x devices. NI-DAQmx technology speeds up your development with many features such as automatic code generation to make configuration and programming easy. NI 651x devices take full advantage of key NI-DAQmx software technologies such as multithreaded streaming technology for dramatic improvements in I/O performance and ease of use. • Use the DAQ Assistant to guide you to fast, accurate measurements with no programming • Use automatic code generation to create your application in LabVIEW, ANSI C, Visual Basic .NET, or C# • Take advantage of multithreaded streaming technology for 1,000X performance improvements Digital I/O Connector The 100-pin high-density SCSI connector on each NI 6511/12/13/14/15 device connects to 100-pin ribbon cables or shielded cables. For low-cost unshielded connectivity, use the R1005050 ribbon cable with two CB-50LP or CB-50 connector blocks (CB-100 kit). For shielded connectivity, use the SH100-100-F shielded digital I/O cable with the SCB-100 connector block. The 37-pin D-Sub connector on NI 6510/16/17/18/19 devices connects to 37-pin accessories including the SH37F-37M shielded digital I/O cable with the CB-37FH DIN-rail-mountable connector block. Ordering Information PCI NI PCI-6510............................................................................779081-01 NI PCI-6511............................................................................778966-01 NI PCI-6512............................................................................778968-01 NI PCI-6513............................................................................778970-01 NI PCI-6514............................................................................778836-01 NI PCI-6515............................................................................778835-01 NI PCI-6516............................................................................779082-01 NI PCI-6517............................................................................779083-01 NI PCI-6518............................................................................779084-01 NI PCI-6519............................................................................779085-01 PXI NI PXI-6511............................................................................778967-01 NI PXI-6512............................................................................778969-01 NI PXI-6513............................................................................778971-01 NI PXI-6514............................................................................778965-01 NI PXI-6515............................................................................778964-01 Recommended Accessories Device NI 6510 NI 6511 NI 6512 NI 6513 NI 6514 NI 6515 NI 6516 NI 6517 NI 6518 NI 6519 Cable SH37F-37M (778621-01) SH100-100-F (185095-02) SH100-100-F (185095-02) SH100-100-F (185095-02) SH100-100-F (185095-02) SH100-100-F (185095-02) SH37F-37M (778621-01) SH37F-37M (778621-01) SH37F-37M (778621-01) SH37F-37M (778621-01) Connector Block CB-37FH (778673-01) SCB-100 (776990-01) SCB-100 (776990-01) SCB-100 (776990-01) SCB-100 (776990-01) SCB-100 (776990-01) CB-37FH (778673-01) CB-37FH (778673-01) CB-37FH (778673-01) CB-37FH (778673-01) BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/daq. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 4 Low-Cost Industrial Digital I/O – 30 V, Bank Isolated Specifications These specifications are typical at 25 °C, unless otherwise noted. Physical Dimensions PCI................................................... 14.1 by 11.4 cm (5.54 by 4.47 in.) PXI................................................... 10.0 by 16 cm (3.9 by 6.3 in.) Digital I/O Number of channels............................ 32 or 64, optically isolated Power-on state.................................... 0 (open), default; user-programmable to 0 or 1 Data transfers ..................................... Interrupts, programmed I/O I/O connector ...................................... 100-pin keyed female SCSI connector or 37-pin male D-Sub connector Environment Operating temperature ....................... 0 to 55 °C The following table lists the derated current values (100% duty cycle). Ambient Temperature Up to 25 °C Up to 35 °C Up to 45 °C Up to 55 °C NI 6512, 6514 6516, 6518 All Lines 75 mA 65 mA 55 mA 50 mA NI 6512, 6514, 6516, 6518 One Line per Port 350 mA 350 mA 350 mA 300 mA NI 6513, 6515, 6517, 6519 All Lines 125 mA 125 mA 115 mA 100 mA NI 6513, 6515, 6517, 6519 One Line per Port 475 mA 425 mA 375 mA 325 mA Isolated Inputs Number of input lines ......................... 0, 16, 32, or 64 bidirectional, each bank with its own ground reference isolated from other banks Bank isolated inputs ........................... 8, 16, or 32 lines per bank Maximum input voltage...................... 30 VDC Level Input logic low-voltage (VIL) Input logic high-voltage (VIH) Min 0 VDC ±11 VDC Max ±4 VDC ±30 VDC Storage temperature........................... -20 to 70 °C Relative humidity ................................ 10 to 90% noncondensing Maximum altitude............................... 2,000 m Note: The NI 651x devices are intended for indoor use only. Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Input current 11 V inputs...................................... 4.5 mA/line, maximum 30 V inputs...................................... 12.5 mA/line, maximum Propagation delay ............................... 75 µs, typical Isolated Outputs Number of lines .................................. 0, 16, 32, or 64, each bank with its own ground reference isolated from other banks Bank isolated outputs ......................... 8, 16, or 32 lines per bank Maximum switching voltage .............. 30 VDC Maximum switching capacity NI 6512, NI 6514, NI 6516, NI 6518 ... 350 mA (75 mA) NI 6513, NI 6515, NI 6517, NI 6519 ... 500 mA (120 mA) Pin 50/Pin 100 (at +5 V) ...................... 200 mA, maximum (only on 100-pin devices) Propagation delay ............................... 80 µs, typical with 100 Ω load Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326 (IEC 61326): Class A emissions; Basic immunity • EN 55011 (CISPR 11): Group 1, Class A emissions • AS/NZS CISPR 11: Group 1, Class A emissions • FCC 47 CFR Part 15B: Class A Power Requirements +5 VDC (±5%)...................................... 150 mA +3.3 VDC (±5%)................................... 300 mA, typical; 500 mA, maximum Power available at I/O connector Voltage............................................ +4.3 to +6.3 VDC Current ............................................ 20 mA/port, typical Note: The power at the I/O connector is derived from the output Vcc (user-provided). The output Vcc must be greater than 10 VDC to ensure that the output voltage is in the range of +4.3 to +6.3 VDC. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 5 NI Services and Support MA IN IN TA PL AN SERVICE NEEDS LO Y V DE EL OP NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. P DE Hardware Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. Calibration Services NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • 800 813 3693 National Instruments • info@ni.com ©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-10837-301-101-D
NIPCI-6519 价格&库存

很抱歉,暂时无法提供与“NIPCI-6519”相匹配的价格&库存,您可以联系我们找货

免费人工找货