High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
NI 673x, NI 671x, NI 672x
• • • • • • • • • Low-cost arbitrary waveform generation High-channel density Integrated multidevice synchronization bus Easy real-time control with LabVIEW Real-Time Digital triggering and external clocking Simultaneous updates 8 digital I/O lines (TTL/CMOS) Two 24-bit counter/timers Measurement services that simplify configuration and measurements
Recommended Software
• • • • LabVIEW 7.x or higher LabWindows™/CVI 7.x or higher Measurement Studio 7.x or higher Analog Waveform Editor
Other Compatible Software
• Visual Studio .NET • Visual Basic, C/C++, and C#
Measurement Services Software (included)1
• NI-DAQmx driver • Measurement & Automation Explorer configuration utility
1Mac
Operating Systems
• Windows 2000/NT/XP • Mac OS X • Linux®
OS X and Linux applications must use
NI-DAQmx Base driver software.
Calibration Certificate Available
Family
NI 6711 NI 6713 NI 6715 NI 6731 NI 6733 NI 6722 NI 6723
1Update
Bus
PCI, PXI PCI, PXI PCMCIA PCI PCI, PXI PCI, PXI PCI, PXI
Analog Outputs
4 8 8 4 8 8 32
Update Rate per Channel (S/s)1 Output Resolution Output Range (V) External Voltage Reference Digital I/O
1M 740 k to 1 M 100 k to 1 M 1M 740 k to 1 M 182 to 800 k 45 to 800 k 12 12 12 16 16 13 13 ±10 ±10 ±10 ±10 ±10 ±10 ±10 – – 8 8 8 82 82 8 8
Counter/Timers
2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit
Triggering
Digital Digital Digital Digital Digital Digital Digital
rate can vary depending on the number of channels used; 2Static or hardware-timed pattern generation and acquisition up to 10 MHz
Table 1. High-Speed Voltage Output Product Selection Guide
Overview and Applications
National Instruments high-speed voltage output devices combine the latest in PC technologies to deliver simultaneous, multichannel updates for control and waveform output applications. Use these modules in a variety of applications, including: • Stimulus/response • Power supply control • High-speed, deterministic control • Sensor/signal simulation
devices, you have complete control of each data point that is updated on the output for each channel. This feature is significant because you can define not only common waveforms such as square, sine, or sawtooth but also complex waveforms. For instance, you are able to create a sine wave that is overlaid with noise in which the amplitude and noise shape are user-defined. In practice, the waveform is defined in a software buffer, within PC memory, and is streamed to the voltage output device using direct memory access (DMA) data transfers. Using DMA transfers, the amount of memory located on board the voltage output device is minimized and is swapped with inexpensive PC memory.
Features
The versatile NI high-speed voltage output devices commonly replace several kinds of instruments including stand-alone PID controllers, low-speed arbitrary waveform generators, and function generators.
Real-Time Control
You can use NI high-speed voltage output devices with the LabVIEW Real-Time Module to deliver real-time, deterministic control loop execution. Because they are compatible with LabVIEW Real-Time, common control algorithms, such as PID, are simple to implement but, more importantly, you may prototype and implement complex, cutting-edge control algorithms as well. High-performance control, on the order of eight PID loops running in excess of 20 kHz each, is possible with this combination of hardware
Waveform Generation
These devices are capable of updating at rates up to 1 MS/s, giving you the ability to generate waveforms up to 500 kHz. When using these
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
and software. Each high-speed voltage output device offers multichannel simultaneous updates and hardware-timed single-point updates. into more than 400 LabVIEW built-in analysis routines for display of results in engineering units on a graph.
Multidevice Synchronization
Each high-speed voltage output device offers the ability to be master or slave of a multidevice timing and triggering system. Use integration technologies such as the RTSI bus, PXI trigger bus, and PFI pins to trigger and synchronize to a wide variety of I/O types. These I/O types range from analog input, image acquisition, motion control, and high-speed digitizers to multifunction data acquisition devices. With these integration infrastructures, you can create powerful, custom test and control systems with ease.
NI-DAQmx Base Driver
NI-DAQmx Base (available at ni.com/downloads) offers Mac OS X and Linux users a programming interface similar to NI-DAQmx. It features ready-to-use LabVIEW VIs and C function features similar to those included in NI-DAQmx driver software.
AO_GND NC
34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35
Measurement Services Software
National Instruments measurement services software, built around NI-DAQmx driver software, features intuitive application programming interfaces, configuration tools, I/O assistants, and other tools designed to reduce system setup, configuration, and development time. This software, part of your data acquisition purchase, includes helpful features such as: Automatic Code Generation – DAQ Assistant is an interactive guide that helps you navigate through configuring, testing, and programming analog output tasks and automatically generates the necessary code for NI LabVIEW, LabWindows/CVI, or Measurement Studio. Cleaner Code Development – Basic and advanced software functions have been combined into one easy-to-use yet powerful set to help you build cleaner code and move from basic to advanced applications without replacing functions. High-Performance Driver Engine – NI-DAQmx delivers maximum I/O system throughput with a multithreaded driver. Test Panels – With the Measurement & Automation Explorer configuration utility, you can test all of your module functionality before you begin development. Scaled Channels – Easily scale your voltage data into the proper engineering units using the NI-DAQmx measurement-ready virtual channels by choosing from a list of common sensors and signals or creating your own custom scale. LabVIEW Integration – All NI-DAQmx functions create the waveform data type, which carries acquired data and timing information directly
AO_GND AO_GND AO_61 AO_GND AO_51 AO_GND AO_GND AO_3 AO_GND AO_GND AO_0 AO_1 EXTREF PO4 D_GND PO1 PO6 D_GND +5 V D_GND D_GND PFI_0 PFI_1 DBND +5 V D_GND PFI_5/AO_SAMP_CLK PFI_6/AO_START_TRIG D_GND PFI_9/CTR_0_GATE CTR_0_OUTT FREQ_OUT
1
NC AO_GND AO_GND AO_71 AO_GND AO_GND NC AO_GND AO_4 AO_GND AOGND AO_2 AO_GND AO_GND AO_GND D_GND DIO0 PO5 D_GND DIO2 PO7 PO3 NC EXTSTROBE D_GND PFI_2 PFI_3/ CTR_1_SOURCE PFI_4/ CTR_1_GATE CTR_1_OUT D_GND PFI_7 PFI_8/CTR_0_SOURCE D_GND D_GND
No Connect on 6711 or 6731
Figure 1. NI 671x and NI 673x I/O Connector
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
2
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
CH0 Amp
CH0 12-Bit DAC
CH1 Amp
CH1 12-Bit DAC
CH2 Amp
CH2 12-Bit DAC
CH3 Amp
CH3 12-Bit DAC
CONFIG EEPROM
CIS EEPROM
CH4 Amp
CH4 12-Bit DAC
Control/Data
I/O Connector
CH5 Amp
CH5 12-Bit DAC
AO Control FIFO Data In Data
FPGA
Data EEPROM
DAQ-STC Calibration Interface Control
CH6 Amp
CH6 12-Bit DAC Control
CH7 Amp
CH7 12-Bit DAC
DAC FIFO
24 8
Calibration DACs Calibration ADC Analog Output Timing/Control PFI / Trigger Timing Trigger Counter/ Timing I/O Bus Interface Analog Input Timing/Control IRQ RTSI Bus Interface
Calibration Mux
DAQ-STC
Digital I/O
Digital I/O (8) +5 V 0.75 A
Figure 2. NI DAQCard-6715 Hardware Block Diagram
Data/Control
Digital Thermometer
Control CH0 Amp CH0 CH0 Latch Data CH1 Amp CH1 CH1 Latch Data DAC FIFO
Address
Generic Mini PCI MITE Bus Bus Interface Interface
Address/Data
EEPROM
IRQ
I/O Connector
CH3/7 Amp
CH3/7
CH3/7 Latch
EEPROM Control AO Control AO Control Calibration Control
Register Decode FPGA DMA/ IRQ DAQ-STC Bus Interface DMA
24 8
Calibration DACs Calibration ADC PFI / Trigger Trigger Counter/ Timing I/O Digital I/O
Data
Calibration Mux
Analog Output Timing/Control
Bus Interface DMA/IRQ RTSI Bus Interface +5 V
Timing
DAQ - STC
Analog Input Timing/Control
Digital I/O (8)
1A RTSI Bus Note: CH4 through CH7 are found on 6713 and 6733 only
Figure 3. NI 671x and NI 673x Hardware Block Diagram
PCI/PXI/CompactPCI
PC Card (PCMCIA) Bus
DAC Control
Bus Interface Bus Interface
Address/Control
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
3
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
Load DAC
13-Bit DAC
13-Bit DAC
13-Bit DAC
13-Bit DAC AO Data Bus 13-Bit DAC EEPROM 13-Bit DAC I/O Connector
13-Bit DAC Analog Output 13-Bit DAC Analog Input
Power On Reset
Misc MITE Interface
PCI M I TE Generic Bus Interface
Control PCI Bus Interface Address/Data PCI Bus
FPGA
FIFO
x41
x41
16-Bit ADC
Update, Busy
Clear
PFI/Trigger
Trigger Timing I/O Digital I/O
Analog Output Timing/Control DAQ - STC
DMA/IRQ DMA/IRQ Bus Interface RTSI Bus Interface
Timing
Digital I/O (8)
1NI
PCI-6723 only
RTSI Bus
Figure 4. NI 672x Hardware Block Diagram
Ordering Information
PCI NI PCI-6711............................................................................777740-01 NI PCI-6713............................................................................777741-01 NI PCI-67221 ..........................................................................778705-01 NI PCI-67231 ..........................................................................778701-01 NI PCI-6731............................................................................778511-01 NI PCI-6733............................................................................778510-01 PXI NI PXI-6711............................................................................777794-01 NI PXI-6713............................................................................777795-01 NI PXI-67221 ..........................................................................778999-01 NI PXI-67231 ..........................................................................778998-01 NI PXI-6733............................................................................778512-01
PCMCIA NI DAQCard-6715 ..................................................................778146-01 Includes data acquisition driver software.
1Windows
only.
For more information on extended warranty and value-added services, visit ni.com/services.
BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/dataacquisition.
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
4
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
Digital logic levels Base clocks available.......................... 20 MHz and 100 kHz Data transfers ..................................... DMA (except DAQCard-6715), interrupts, programmed I/O DMA modes ........................................ Scatter-gather
Specifications – NI 671x, NI 673x
These specifications are typical at 25 °C unless otherwise stated.
Analog Output
Output Characteristics
Number of channels NI 6715/6713/6733 ........................ 8 voltage outputs NI 6711/6731.................................. 4 voltage outputs Resolution ........................................... 12 bits, 1 in 4,096 (NI 671x), 16 bits, 1 in 65,536 (NI 673x)
Maximum Update Rate (NI 671x/673x) Max Update Rate (NI 6715) Using Local Using Host Using Local Using Host FIFO (kS/s)1 Memory (kS/s)2 FIFO (kS/s)1 Memory (kS/s)2 1,000 1,000 1,000 800 1,000 1,000 850 400 1,000 1,000 750 266 1,000 1,000 650 200 1,000 1,000 600 160 952 1,000 550 133 833 869 510 114 740 769 480 100
Digital Trigger
Purpose Analog output ................................. General-purpose counter/timers .... Source ................................................. PCI................................................... PXI................................................... Slope ................................................... Start trigger, gate, clock Source, gate (except NI 6715) RTSI PFI Positive or negative; software-selectable Compatibility ....................................... 5 V TTL/CMOS
Number of Channels
1 2 3 4 5 6 7 8
Specifications – NI 672x
These specifications are typical at 25 °C unless otherwise stated.
Analog Output
Output Characteristics
Number of channels NI 6722 ........................................... 8 voltage outputs
Max Update Rate (kS/s) Using Local FIFO1 Using Host PC Memory2 800 800 714 714 476 182 333 90.9 253 60 204 45
1These numbers apply to continuous waveform generation, and do not change irrespective of the number of devices
in the system. 2These numbers may change when using more devices or when other CPU or bus activity is taking place.
FIFO buffer size NI 6713/6733.................................. 16,384 samples NI 6711/6715/6731 ........................ 8,192 samples Data transfers ..................................... DMA, interrupts, programmed I/O DMA modes (PXI/PCI only) ................. Scatter-gather
Voltage Output
Ranges................................................. ±10.0 V, ±AO EXT REF Output coupling................................... DC Protection ............................................ Short-circuit to ground
Number of Channels 1 2 8 16 24 32
1These numbers apply to continuous waveform generation, which allows for the time it takes to reset the FIFO to the beginning when cycling through it. This additional time is not incurred when using host PC memory for waveform generation. The max update rate in FIFO mode does not change regardless of the number of devices in the system. 2These
Digital I/O
Number of channels............................ Compatibility ....................................... Power-on state.................................... Data transfers ...................................... 8 input/output 5 V TTL/CMOS Input (high-impedance) Programmed I/O, DMA (NI 673x), interrupts (NI 673x) Input buffer ......................................... 2048 B (NI 673x) Output buffer....................................... 2048 B (NI 673x) Transfer rate........................................ 10 Mwords/s (NI 673x)
results were measured using an NI 6722/6723 device with a 550 MHz Pentium III machine. These numbers may change when using more devices or when other CPU or bus activity occurs.
NI 6723 ........................................... Resolution ........................................... Max update rate FIFO buffer size ................................... Data transfers ........................................ DMA modes ........................................
32 voltage outputs 13 bits, 1 in 8,192 2,048 samples DMA, interrupts, programmed I/O Scatter gather
Timing I/O
General-Purpose Up/Down Counter/Timers
Number of channels............................ 2 Resolution ........................................... 24 bits Compatibility ....................................... 5 V TTL/CMOS
Level
Input low voltage Input high voltage Output low voltage (Iout = 5 mA) Output high voltage (Iout = -3.5 mA)
Voltage Output
Ranges................................................. ±10 V Output coupling................................... DC Protection ............................................ Short-circuit to ground
Digital I/O
Maximum 0.8 V 5V 0.4 V –
Minimum 0V 2V – 4.35 V
Number of channels............................ Compatibility ....................................... Power-on state.................................... Data transfers .....................................
8 input/output TTL/CMOS Input (high-impedance) Programmed I/O
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
5
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
Timing I/O
Number of channels Up/down counter/timers ................ Frequency scaler............................. Resolution Up/down counter/timers ................ Frequency scaler............................. Compatibility ....................................... Digital logic levels
Level Input low voltage Input high voltage Output low voltage (Iout = 5 mA) Output high voltage (Iout = -3.5 mA)
I/O Connector Blocks
2 1 24 bits 4 bits 5 V TTL/CMOS BNC-2110 – Shielded I/O connector block with signal-labeled BNC connectors for easy connectivity of your analog output (AO), digital I/O (DIO), and counter/timer signals. BNC-2110..............................................................................777643-01 Dimensions – 20.3 by 11.2 by 5.5 cm (8.0 by 4.4 by 2.2 in.) BNC-2115 – Shielded I/O connector block with signal-labeled BNC connectors for easy connectivity of your extended analog output on NI 6723 devices. BNC-2115..............................................................................777807-01 Dimensions – 20.3 by 11.2 by 5.5 cm (8.0 by 4.4 by 2.2 in.) SCB-68 – Shielded I/O connector blocks giving you rugged, very low-noise signal termination. The SCB-68 also houses silk-screened component locations for easy addition of simple signal conditioning circuitry for your AO channels. SCB-68 ..................................................................................776844-01 Dimensions – 19.5 by 15.2 by 4.5 cm (7.7 by 6.0 by 1.8 in.) CA-1000 – Configurable enclosure that gives you user-defined connectivity and flexibility through customized panelettes. CA-1000 ..............................................................................777664-01 Dimensions – 30.7 by 25.4 by 4.3 cm (12.1 by 10 by 1.7 in.) TBX-68 – 68 screw terminals for easy connection of field signals to 68-pin DAQ devices. It includes one 68-pin male connector for direct connection to 68-pin cables. The TBX-68 is mounted in a protective plastic base with hardware for mounting on a standard DIN rail. TBX-68 ..................................................................................777141-01 Dimensions – 12.50 by 10.74 cm (4.92 by 4.23 in.) CB-68LP, CB-68LPR – 68 screw terminals for easy connection of field signals to AO devices. They include one 68-pin male connector for direct connection to 68-pin cables. The connector blocks include standoffs for use on a desktop or for mounting in a custom panel. The CB-68LP has a vertical mounted 68-pin connector. The CB-68LPR has a right-angle mounted connector and can also be used with the CA-1000. CB-68LP ................................................................................777145-01 Dimensions – 14.35 by 10.74 cm (5.65 by 4.23 in.) Dimensions – 7.62 by 16.19 cm (3.00 by 6.36 in.) TB-2705 – 68-pin screw-terminal block for PXI-671x and PXI-673x modules. Latches to the front of your PXI module with locking screws and provides strain relief as well as easy access to your analog, digital,
Min 0.0 V 2.0 V – 4.35 V
Max 0.8 V 5.0 V 0.4 V –
Data transfers Up/down counter/timers ................ DMA (scatter-gather), interrupts, programmed I/O Frequency scaler............................. Programmed I/O
Digital Trigger
Purpose Analog output ................................. Counter/timers................................ Source ................................................. Compatibility ....................................... Response............................................. Start trigger, gate, clock Source, gate PFI 5 V TTL Rising or falling edge
For more detailed specifications, please refer to the product manual.
High-Speed Voltage Output Cables and Accessories Recommended Configurations
• • • • • Shielded options for minimal noise interference Direct connectivity options such as BNC Low-cost options for OEM Front-mount terminal block for PXI Custom connectivity with the CA-1000
Connect to … Cable Accessory BNC SH68-68-EP BNC-2110 Screw terminals SH68-68-EP SCB-68 or TBX-68 Screw terminals – TB-2705 (PXI) Custom SH68-68-EP CA-1000 Screw terminals R6868 CB-68LP or CB-68LPR BNC 2 SH68-C68-S BNC-2110 and BNC-2115 2 SCB-68 or TBX-68 Screw terminals 2 SH68-C68-S Custom 2 SH68-C68-S 2 CA-1000 BNC SH68-C68-S BNC-2110 Screw terminals SH68-C68-S SCB-68 Custom SH68-C68-S CA-1000 Screw terminals RC68-68 CB-68LP or CB-68LPR BNC SHC68-68-EPM BNC-2110 Screw terminals SHC68-68-EPM SCB-68 Custom SHC68-68-EPM CA-1000 Screw terminals RC68-68 CB-68LP or CB-68LPR
Model
Shielding Shielded Shielded Shielded Shielded Unshielded Shielded NI 6723 Shielded Shielded Shielded NI 6722 Shielded Shielded Unshielded DAQCard-6715 Shielded Shielded Shielded Unshielded
NI 673x, NI 671x
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
6
High-Speed Voltage Output – up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels
trigger, and counter/timer signals through screw terminals. Does not work with NI 6703 or NI 6704 devices. TB-2705 ................................................................................778241-01 Dimensions – 8.43 by 10.41 by 2.03 cm (3.32 by 4.1 by 0.8 in.) stability. Use this cable for a DAQCard located in the bottom PCMCIA slot of a laptop. 0.5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186838-0R5 1 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186838-01 SHC68U-68-EP – Identical to the SHC68-68-EP, except that the DAQCard connector is inverted so you can use two latching DAQCard devices in adjacent slots. Use this cable with a DAQCard inserted in the upper PCMCIA slot of a laptop. 0.5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187406-0R5 1 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187406-01 SH68-C68-S – Shielded cable for connecting and latching NI 672x devices to standard 68-pin accessories. 2 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186381-02
Synchronization Cables
RTSI Bus Cables – Used to connect timing and synchronization signals among measurement, vision, motion, and CAN boards for PCI. For systems with long and short boards, use the extended RTSI cable. 2 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .776249-02 3 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..776249-03 4 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .776249-04 5 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .776249-05 Extended, 5 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .777562-05
Shielded I/O Cables
SH68-68-EP – Shielded 68-conductor cable terminated with two 68-pin female 0.050 series D-type connectors, featuring individually shielded analog twisted pairs for reduced crosstalk with high-speed devices. This cable works with all NI 671x and NI 673x devices. 1 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184749-01 SHC68-68-EP – Shielded cable for connecting and latching the NI DAQCard-6715, NI 6722, and NI 6723 to standard 68-pin accessories. Latching screws secure the shielded connector to the device itself for
Ribbon I/O Cables
R6868 – 68-conductor flat ribbon cable terminated with two 68-pin connectors. Use this cable to connect the NI 670x, NI 671x, and NI 673x devices to low-cost 68-pin accessories. 1 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182482-01 RC68-68 – 68-conductor flat ribbon cable terminated with one VHDCI 68-pin connector and one 68-pin SCSI II connector. Use this cable to connect the NI 6722 devices and DAQCard-6715 with standard 68-pin accessories. 1 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187252-01
BNC-2110
SCB-68
CA-1000
CB-68LP I/O and CB-68LPR
TB-2705
RTSI Bus Cable
SH68-68-EP Shielded Cable
SHC68-68-EP
R6868 Ribbon Cable
RC68-68 Ribbon Cable
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
7
NI Services and Support
NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is composed of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration.
OEM Support
We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com • (800) 813 3693
National Instruments • info@ni.com
*351432A-01*
351432A-01 2006-7838-301-101-D
© 2006 National Instruments Corporation. All rights reserved. CVI, DAQCard, DAQ-STC, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, NI, ni.com, RTSI, and SCXI are trademarks of National Instruments. Linux® is a registered trademark of Linus Torvalds in the U.S. and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.