0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIPXI-2527

NIPXI-2527

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIPXI-2527 - Low-Cost 6 1⁄2-Digit Multimeters - National Instruments Corporation

  • 数据手册
  • 价格&库存
NIPXI-2527 数据手册
Low-Cost 61⁄2-Digit Multimeters NI PXI-4065, NI PCI-4065, NI PCIe-4065, NI USB-4065 NEW! • Basic 6 1⁄2-digit digital multimeters (DMMs) for PXI, PCI, PCI Express, and USB • 7 built-in measurement modes – AC/DC voltage, AC/DC current, 2- or 4-wire resistance, and diode test • ±300 VDC/Vrms isolation • 10 readings/s maximum at 61⁄2 digits • Ideally suited for OEMs, educational labs, and production test For increased accuracy, resolution, measurement speed, and functionality, consider NI 407x FlexDMM devices. 1PXI-4065 Operating Systems • Windows Vista/XP/2000 Recommended Software • • • • • LabVIEW LabVIEW Real-Time Module1 LabWindows™/CVI Measurement Studio LabVIEW SignalExpress Other Compatible Software • Microsoft Visual Basic • C/C++ Driver Software (included) • NI-DMM • NI-DMM Soft Front Panel • DMM/Switch Express VI only Overview National Instruments 4065 devices are low-cost 6 1⁄2-digit PXI, PCI, PCI Express, and USB DMMs for the measurement of voltage, current, and resistance, or for diode test. They are ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement facilities. With ±300 VDC/Vrms of isolation, current measurements up to 3 A, and 2- or 4-wire resistance measurements, NI 4065 DMMs provide a complete multimeter solution for basic 6 1⁄2-digit measurement needs. For higher-performance requirements, consider using NI 407x PCI and PXI FlexDMM devices. They combine industry-leading accuracy and resolution at 6 1⁄2 and 7 1⁄2 digits with 1.8 MS/s digitizer capability for faster sampling rates in production test environments. Efficient Mixture of Accuracy, Resolution, and Speed NI 4065 DMMs offer 6 1⁄2 digits of resolution at up to 10 readings/s and up to 3000 readings/s at lower resolutions. By trading off speed for resolution, you can maximize measurement quality and throughput. NI 4065 DMMs also offer comparable accuracy over a 24-hour cycle or one year of an external calibration to other GPIB, LAN, or USB-based Digits 61⁄2 51⁄2 41⁄2 Resolution (bits) 22 18 15 Reading Rate (S/s) 10 1500 3000 Table 1. NI 4065 Reading Rates versus Resolution Flexible Software Improves Usability You can program NI 4065 DMMs through a standard application programming interface (API) in NI LabVIEW and LabWindows/CVI or Microsoft programming languages. For simple benchtop measurements, the NI-DMM Soft Front Panel provides the common display and interface found on traditional DMMs to make simple measurements quickly and easily. When combined with switches, the DMM/Switch Express VI can rapidly develop a high-channel-count data-logging system with a single function call in LabVIEW. In LabVIEW SignalExpress, the DMM/Switch Express VI sets up a live data logger without any programming. 6 1⁄2-digit DMMs on the market. With an NI 4065, there is no need to sacrifice basic measurement quality for a low selling price. For higher resolution, accuracy, or speed, consider using one of the NI 407x 6 1⁄2-digit FlexDMM devices. The PCI-4070 can accurately measure 100 readings/s at 61⁄2 digits with 31 ppm of DC voltage accuracy over a two-year period. This represents a 3X improvement over the NI 4065 DMMs for accuracy and noise. The PXI-4071 is also available with measurements at 7 1⁄2 digits up to 1000 V. For more information on the complete line of National Instruments DMMs, visit ni.com/multimeters. Low-Cost 6 1⁄2-Digit Multimeters Integration with Switching NI PXI-4065 You can easily combine the NI PXI-4065 DMM with NI PXI switches in the low-cost NI PXI-1033 integrated chassis and controller to create highchannel-count, 6 1⁄2-digit data-logging systems with up to 588 channels. You can configure these systems, controllable from any PCI Express or ExpressCard slot on a PC or laptop computer, with more than 100 available PXI switch topologies. For further system expansion, you can add more than 3,000 channels with each additional 18-slot PXI chassis. Figure 3. Use the USB-4065 with USB-controlled switching for a complete DMM/switch solution. Ordering Information Figure 1. Expand channel count with PXI switching. NI USB-4065, PCI-4065 and PCIe-4065 You can integrate NI 4065 DMMs with stand-alone switching using the 4- or 12-slot USB Switch Mainframes from National Instruments. You can configure these switch systems, controllable from any available USB port on a PC or laptop computer, with more than 50 available SCXI switch topologies. For existing SCXI switch systems, the NI 4065 DMMs can also provide control via the AUX connector on the front of the DMM. Switching offers a simple method of channel expansion for data-logging systems based on an NI 4065. NI PXI-4065............................................................................780011-01 NI PCI-4065............................................................................779770-01 NI PCIe-4065..........................................................................779771-01 NI USB-4065 ..........................................................................780152-01 Includes the standard P-1 probe set and NI-DMM software. Accessories for PXI NI PXI-1033 (chassis and integrated MXI Express controller, 1 PXI Express port, 3 m cable) ..............................................779756-01 NI PXI-2527 (300 V, 64-channel multiplexer) ........................778572-27 Accessories for USB, PCI, and PCI Express NI USB Switch Mainframe (4-slot) ......................................778570-01 NI SCXI-1127 (300 V, 64-channel multiplexer)......................776572-27 General Accessories P-1 Probe Set (standard)........................................................761000-01 P-2 Probe Set (additional connectors) ..................................184698-01 P-3 Probe Set (banana plug to bare wire) ............................185692-01 CSM-10 A (10 A current shunt) ............................................777488-02 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/multimeters. Figure 2. Expand channel count with USB-controlled switching. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 2 Low-Cost 6 1⁄2-Digit Multimeters Specifications DC Specifications Resolution (Digits) 61⁄2 Reading Rate1 (S/s) 0.6 (0.5) 6 (5) 10 (8.33) 30 (25) 60 (50) 900 1,500 3,000 Aperture Time (NPLC) 100 10 6 2 1 0.06 0.04 0.02 RMS Noise2 (ppm of range) 0.06 0.2 0.25 0.4 0.55 1.7 2.5 11.5 51⁄2 41⁄2 1 Specified 2 for 60 Hz and (50 Hz) operation Measured on the 10 V range DC Voltage ± (ppm of reading + ppm of range)1 Range 100 mV3 1V 10 V 100 V 300 V 1ppm 2Relative 3With Resolution 100 nV 1 µV 10 µV 100 µV 1 mV Input Resistance4 >10 GΩ, 10 MΩ >10 GΩ, 10 MΩ >10 GΩ, 10 MΩ 10 MΩ 10 MΩ 24-Hour2, Tcal ±1 °C 30 + 30 20 + 6 15 + 5 20 + 6 20 + 20 90-Day, Tcal ±5 °C 65 + 35 65 + 7 65 + 6 75 + 7 75 + 20 1-Year, Tcal ±5 °C 90 + 35 90 + 7 90 + 6 110 + 7 110 + 20 Tempco (0 to 55 °C) 5+2 5 + 0.2 5 + 0.2 6 + 0.2 6 + 0.5 (part per million) = 0.0001% to external calibration source offset nulling 4Default input resistance is 10 MΩ Tcal = temperature at which last external calibration was performed NI factory calibration is 23 ˚C ± 1 ˚C Tempco = temperature coefficient DC Current ± (ppm of reading + ppm of range) Range 10 mA 100 mA 1A 3A 1Add 2Relative Resolution 10 nA 100 nA 1 µA 3 µA Burden Voltage (typical) 40 Hz to 5 kHz 24-Hour, Tcal ±1 °C 1.6 + 0.05 0.3 + 0.05 90-Day, Tcal ±5 °C 2.1 + 0.05 0.3 + 0.06 1-Year, Tcal ±5 °C 2.1 + 0.05 0.3 + 0.06 Tempco (0 to 55 ˚C) 0.015 + 0.03 0.015 + 0.03 High Crest Factor Additional Error1 Crest Factor 1 to 3 3 to 4 4 to 5 1Applicable 2For Additional Error (% of reading) 0.05% 0.1% 1%2 for non-sine wave signals up to the rated peak voltage/current or bandwidth frequencies above 2 kHz AC Functions General Specifications Input impedance .................................................................... Input coupling ........................................................................ Maximum volt-hertz product ................................................. Maximum DC voltage component ......................................... CMRR (1 kΩ resistance in LO lead) ...................................... Overrange............................................................................... 10 MΩ in parallel with 200 pF AC coupling >3 x 107 V-Hz 250 V >70 dB (DC to 60 Hz) 105% of range except 300 V, 3 A range 1 year recommended Up to 300 VDC Up to 300 VDC, 300 Vrms, 450 Vp F 3.15 A 250 V fast-acting fuse, user-replaceable General Specifications External calibration interval .................................................. Input protection Resistance, diode .............................................................. DC V, AC V ......................................................................... DC I and AC I ..................................................................... BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 4 Low-Cost 6 1⁄2-Digit Multimeters Maximum common-mode voltage......................................... 300 VDC or Vrms Input terminals....................................................................... Gold-plated low-thermal emf solid copper Dimensions ............................................................................ PXI: 3U, 1 slot, PXI/CompactPCI module; 21.6 by 2.0 by 13.0 cm (8.5 by 0.8 by 5.1 in.) PCI/PCI Express: 1 slot, PCI or PCI Express board; 18.3 by 12 cm (7.2 by 4.72 in.) USB: 17.8 by 10.4 by 3.3 cm (7.0 by 4.1 by 1.3 in.) Operating temperature .......................................................... PXI: 0 to 55 °C; PCI/PCI Express: 0 to 40 °C; USB: 0 to 45°C Storage temperature.............................................................. -40 to 70 °C Relative humidity ................................................................... Up to 95% at 40 °C Measurement category.......................................................... CAT II Pollution degree..................................................................... 2 Approved at altitudes ............................................................ Up to 2000 m Safety An NI 4065 meets the requirements of the following standards of safety and electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: • EN 61326 EMC requirements; Minimum Immunity • EN 55011 Emissions; Group 1, Class A • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note: For EMC compliance, operate this device according to product documentation. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 5 NI Services and Support IN TA PL SERVICE NEEDS LO Y V DE NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. MA IN Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. EL OP AN Professional Services Our Professional Services Team is composed of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. P DE Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • 800 813 3693 National Instruments • info@ni.com *351556A-01* 351556A-01 2007-8778-101-D © 2008 National Instruments Corporation. All rights reserved. CVI, FlexDMM, LabVIEW, Measurement Studio, MXI, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
NIPXI-2527 价格&库存

很抱歉,暂时无法提供与“NIPXI-2527”相匹配的价格&库存,您可以联系我们找货

免费人工找货