0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIPXI-2586

NIPXI-2586

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIPXI-2586 - 10-Channel, 12 A SPST (Form A) Relays/Multiplexer - National Instruments Corporation

  • 数据手册
  • 价格&库存
NIPXI-2586 数据手册
10-Channel, 12 A SPST (Form A) Relays/Multiplexer NI PXI-2585, NI PXI-2586 • Configurations • PXI-2585: 10x1 multiplexer • PXI-2586: 10 SPST (Form A) nonlatching relays • Switch capacity • Up to 300 VDC/300 VAC CAT II • Up to 12 A switching/12 A carry • Maximum switching power (per channel) • AC – 3000 VA (to 60 Hz) • DC – See Figure 1 • Onboard relay counting • Fully software programmable • 32,000-step scanlist for deterministic scanning • Tight synchronization with instruments through hardware triggers • 65 cycles/s NEW Operating Systems • Windows 2000/NT/XP Recommended Software • NI Switch Executive • LabVIEW • LabWindows/CVI • Measurement Studio Other Compatible Software • Visual Basic • C/C++ Driver/Services Software (included) • NI-SWITCH • NI-DAQmx Overview The National Instruments PXI-2585 and PXI-2586 are high-power switch modules in a single-slot, 3U PXI form factor. They each have 10 channels, with the PXI-2585 configured as a 10x1 multiplexer and the PXI-2586 configured as independent SPST (Form A) relays. Both have low contact resistance and high isolation voltage. The NI PXI2585 and PXI-2586, rated for both high currents (up to 12 A) and high voltages (up to 300 VDC/300 VAC), are ideal for switching power signals and loads in control applications, and battery, power supply, and automotive testing. In AC applications, they can switch up to 3000 VA. For DC, see Figure 1. Automatic Scanning The PXI-2585 and PXI-2586 maximize throughput in automated test applications by the use of scanning. Scanning improves throughput by downloading a list of up to 32,000 connections to the switch and cycling through the list using an event (trigger) without any interruption from the host processor. Scanning is most efficiently accomplished by mating the PXI-2585 and PXI-2586 with a companion modular instrument that will issue a trigger after each measurement is complete. Software All National Instruments PXI and SCXI switch modules are shipped with NI-SWITCH, an IVI-compliant driver offering complete functionality for all switch modules. For additional assistance in configuring, programming, and managing higher-channel-count switching systems, NI Switch Executive software offers an easy-to use, intelligent switch management and visual routing environment. Ordering Information NI PXI-2585 ..................................................................778572-85 NI PXI-2586 ..................................................................778572-86 Accessories Figure 1. Maximum Switching Power for DC Loads (per channel) Connector and backshell ..............................................779168-01 NI Switch Executive Development System ................................................778546-01 Deployment Engine ..................................................778548-00 Relay Count Tracking The PXI-2585 and PXI-2586 count each relay closure on each of its high-power relays. The counts are stored onboard and can be retrieved as necessary for predictive maintenance to reduce unexpected system downtime. BUY ONLINE! For complete product specifications, pricing, and accessory information, call (800) 813-3693 (U.S. only) or go to ni.com/switches 10-Channel, 12 A SPST (Form A) Relays/Multiplexer Specifications Relay Characteristics Number of channels PXI-2585..................................................... PXI-2586..................................................... Relay type......................................................... Maximum switching voltage AC ..............................................300 VAC DC ..............................................300 VDC Maximum switching current ............................ Maximum carry current.................................... Maximum AC switching power........................ Maximum DC switching power 10x1 10 SPST, normally open, nonlatching Physical Relay type......................................................... Relay contact material ..................................... I/O connector.................................................... Dimensions....................................................... Armature AgNi Positronic GMCT20M0T0000 Single PXI slot, 3U Environment 12 A 12 A 3000 VA Operating temperature..................................... 0 to 55 °C Storage temperature ........................................ -20 to 70 °C Relative humidity ............................................. 5 to 85% noncondensing Pollution degree ............................................... 2 Approved at altitudes up to 2000 m Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1 • CAN/CSA-C22.2 No. 61010-1 Electromagnetic Compatibility Emissions.......................................................... EN 55011 Class A at 10 m; FCC ................................................................... Part 15A above 1 GHz Immunity........................................................... EN 61326:1997 + A2:2001, Table A.1 CE, C-Tick, and FCC Part 15 (Class A) Compliant For EMC compliance, operate this device with shielded cabling. Figure 2. Maximum Switching Power for DC Loads (per channel) DC path resistance Initial.......................................................... ≤ 50 mΩ End of life .................................................. >100 mΩ Minimum switching capacity........................... 12 V or 100 mA CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows: Low-Voltage Directive (safety)......................... 73/23/EEC Electromagnetic Compatibility Directive (EMC).......................................... 89/336/EEC Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Dynamic Characteristics Maximum cycle speed ..................................... Relay operate time Typical........................................................ Maximum................................................... Expected relay life Mechanical ................................................ Electrical 30 VDC, 10 ADC resistive.......................... 30 VDC, 12 ADC resistive.......................... AC contact life 65 cycles/s 7.4 ms 15.4 ms 1 x 107 cycles 1 x 105 cycles 3 x 104 cycles Figure 3. Contact Life for Resistive AC Load (Typical) 2 National Instruments • Tel: (800) 813-3693 • Fax: (512) 683-9300 • info@ni.com • ni.com NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services for more information. Local Sales and Technical Support In offices worldwide, NI staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through an online KnowledgeBase, applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. SERVICE NEEDS Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. NI schedules instructor-led courses in cities worldwide, or can hold a course at your facility. NI also offers a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services The NI Professional Services Team is comprised of NI applications engineers, NI consulting services, and a worldwide National Instruments Alliance Partner Program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance for more information. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem for more information. NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 813-3693 National Instruments • Fax: (512) 683-9300 • info@ni.com © 2004 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments Alliance Partner, ni.com, NI-DAQ, NI Switch Executive, and SCXI are trademarks or trade names of National Instruments. Other products and company names listed are trademarks or trade names of their respective companies. National Instruments Alliance Partner Program Members are business entities independent from National Instruments and have no agency, partnership or joint-venture relationship with National Instruments.
NIPXI-2586 价格&库存

很抱歉,暂时无法提供与“NIPXI-2586”相匹配的价格&库存,您可以联系我们找货

免费人工找货