0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIPXI-6052E

NIPXI-6052E

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIPXI-6052E - Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analo...

  • 数据手册
  • 价格&库存
NIPXI-6052E 数据手册
Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs Full-Featured E Series Multifunction DAQ E Series – Full-Featured • 16 or 64 analog inputs at up to 1.25 MS/s, 12 or 16-bit resolution • 2 analog outputs at up to 1 MS/s, 12 or 16-bit resolution • 8 digital I/O lines (TTL/CMOS); two 24-bit counter/timers • Analog and digital triggering • 14 or 15 analog input signal ranges • NI-DAQ driver simplifies configuration and measurements Operating Systems • Windows 2000/NT/XP • Real-time performance with LabVIEW (page 134) • Others such as Linux and Mac OS X (page 187) Recommended Software • LabVIEW • LabWindows/CVI • Measurement Studio • VI Logger Families • NI 6071E • NI 6070E • NI 6062E • NI 6052E • NI 6040E • NI 6033E • NI 6032E • NI 6031E • NI 6030E • NI 6020E (only digital triggering) Other Compatible Software • Visual Basic, C/C++, and C# Driver Software (included) • NI-DAQ 7 Calibration Certificate Included See page 21. Family NI 6071E NI 6070E NI 6062E NI 6052E NI 6040E NI 6033E NI 6032E NI 6031E NI 6030E NI 6020E Bus PCI, PXI PCI, PXI, FireWire PCMCIA PCI, PXI, FireWire PCI, PXI PCI PCI PCI, PXI PCI, PXI NI USB Analog Inputs 64 SE/32 DI 16 SE/8 DI 16 SE/8 DI 16 SE/8 DI 16 SE/8 DI 64 SE/32 DI 16 SE/8 DI 64 SE/32 DI 16 SE/8 DI 16 SE/8 DI Input Resolution 12 bits 12 bits 12 bits 16 bits 12 bits 16 bits 16 bits 16 bits 16 bits 12 bits Max Sampling Rate 1.25 MS/s 1.25 MS/s 500 kS/s 333 kS/s 500 kS/s 100 kS/s 100 kS/s 100 kS/s 100 kS/s 100 kS/s Input Range ±0.05 to ±10 V ±0.05 to ±10 V ±0.05 to ±10 V ±0.05 to ±10 V ±0.05 to ±10 V ±0.1 to ±10 V ±0.1 to ±10 V ±0.1 to ±10 V ±0.1 to ±10 V ±0.05 to ±10 V Analog Outputs 2 2 2 2 2 0 0 2 2 2 Output Resolution 12 bits 12 bits 12 bits 16 bits 12 bits 16 bits 16 bits 12 bits Output Rate 1 MS/s 1 MS/s 850 kS/s 333 kS/s 1 MS/s 100 kS/s 100 kS/s 20 S/s Output Range ±10 V ±10 V ±10 V ±10 V ±10 V ±10 V ±10 V ±10 V Digital I/O 8 8 8 8 8 8 8 8 8 8 Counter/Timers 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit Triggers Analog, digital Analog, digital Analog, digital Analog, digital Analog, digital Analog, digital Analog, digital Analog, digital Analog, digital Digital Data Acquisition and Signal Conditioning Table 1. NI Full-Featured E Series Model Guide (See page 228 for detailed specifications.) Overview and Applications NI Full-Featured E Series devices are the fastest and the most accurate multiplexed data acquisition devices available. They are ideal for applications ranging from continuous high-speed data logging to control applications to high voltage signal or sensor measurements when used with NI signal conditioning. Synchronize the operations of multiple devices using the RTSI bus or PXI trigger bus and easily integrate other hardware such as motion control and machine vision to create an entire measurement and control system. Visit ni.com/oem for information on our quantity discounts for OEM customers. Highly Accurate Hardware Design NI Full-Featured E Series DAQ devices includethe following features and technologies: Temperature Drift Protection Circuitry – Designed with components that minimize the effect of temperature changes on measurements to less than 0.0006% of reading per °C. Resolution-Improvement Technologies – Carefully designed noise floor maximizes resolution. Onboard Self-Calibration – Precise voltage reference included for calibration and measurement accuracy. Self-calibration is completely software controlled, with no potentiometers to adjust. NI DAQ-STC – Timing and control ASIC designed to provide more flexibility, lower power consumption, and a higher immunity to noise and jitter than off-the-shelf counter/timer chips. National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 199 Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs Full-Featured E Series Multifunction DAQ NI MITE – ASIC designed to optimize data transfer for multiple simultaneous operations using bus mastering with three scattergather DMA channels for maximum performance of concurrent I/O operations. NI PGIA – Measurement and instrument class amplifier that guarantees settling times at all gains. Typical commercial off-theshelf amplifier components do not meet the settling time requirements for high-gain measurement applications. PFI Lines – Eight programmable function input (PFI) lines that can be used for software-controlled routing of interboard and intraboard digital and timing signals. RTSI or PXI Trigger Bus – Used to share timing and control signals between devices and synchronize operations. RSE Mode – In addition to differential and nonreferenced singleended modes, NI full-featured E Series devices offer referenced single-ended (RSE) mode for use with floating signal sources in applications with channel counts higher than eight. High-Performance Driver Engine – Software-timed single-point input (typically used in control loops) with NI-DAQ achieves rates of up to 50 kHz. NI-DAQ also delivers maximum I/O system throughput with a multithreaded driver. Test Panels – With NI-DAQ, you can test all of your device functionality before you begin development. Scaled Channels – Easily scale your voltage data into the proper engineering units using the NI-DAQ Measurement Ready virtual channels by choosing from a list of common sensors and signals or creating your own custom scale. LabVIEW Integration – All NI-DAQ functions use the waveform data type, which carries acquired data and timing information directly into more than 400 LabVIEW built-in analysis routines for display of results in engineering units on a graph. Worldwide Support and Services NI provides you with a wealth of resources to help you get your application up and running more quickly, including: Technical Support – Purchase of NI hardware or software gives you access to application engineers all over the world as well as Web resources with more than 3,000 measurement examples and more than 9,000 KnowledgeBase entries. – ni.com/support NI Factory Installation Services (FIS) – Software and hardware installed in PXI and PXI/SCXI systems, tested and ready to use – ni.com/advisor Calibration – Includes NIST-traceable basic calibration certificates, services for ANSI/NCSL-Z540 and periodic calibration – ni.com/calibration Data Acquisition and Signal Conditioning Onboard Temperature Sensor – Included for monitoring the operating temperature of the device to ensure that it is operating within the specified range. Analog and Digital Triggering – Only full-featured E Series devices provide the ability to set a trigger based on the level of an analog signal, in addition to the ability to trigger off an edge of a digital signal. More Input Ranges – Up to 15 input ranges for optimal resolution, even for signals smaller than 50 mV. High-Performance, Easy-to-Use Driver Software NI-DAQ is the robust driver software that makes it easy to access the functionality of your data acquisition hardware, whether you are a beginning or advanced user. Helpful features include: Automatic Code Generation – DAQ Assistant is an interactive guide that steps you through configuring, testing, and programming measurement tasks, and generating the necessary code automatically for use in LabVIEW, LabWindows/CVI, or Measurement Studio. Cleaner Code Development – Basic and advanced software functions have been combined into one easy-to-use yet powerful set to help you build cleaner code and move from basic to advanced applications without replacing functions. Extended Warranty – Meet project life-cycle requirements and maintain optimal performance in a cost-effective way – ni.com/services Data Acquisition Training – Instructor-led courses – ni.com/training Professional Services – Feasibility, consulting, and integration through our Alliance Partners – ni.com/alliance For more information on NI services and support, please visit ni.com/services For information on device support in NI-DAQ 7, visit ni.com/dataacquisition 200 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs Full-Featured E Series Multifunction DAQ Models NI 6030E, NI 6031E, NI 6032E, NI 6033E Measurement Sensitivity* (mV) 0.0023 Nominal Range (V) Positive FS Negative FS 10 -10 1.147 5 -5 2.077 2.5 -2.5 – 2 -2 0.836 1 -1 0.422 0.5 -0.5 0.215 0.25 -0.25 – 0.2 -0.2 0.102 0.1 -0.1 0.061 0.05 -0.05 – 10 0 0.976 5 0 1.992 2 0 0.802 1 0 0.405 0.5 0 0.207 0.2 0 0.098 0.1 0 0.059 Full-Featured E Series NI 6052E NI 6070E, NI 6071E 0.0025 0.009 NI 6040E 0.008 Low-Cost E Series NI 6034E, NI 6036E NI 6023E, NI 6024E, NI 6025E 0.0036 0.008 Basic PCI-6013, PCI-6014 0.004 Absolute Accuracy (mV) 15.373 7.56 5.697 1.79 3.859 – – – 1.556 – 0.789 0.399 0.405 – – – 0.176 – 0.100 0.0611 7.269 – 5.645 – 2.271 – 1.146 – 0.583 – 0.247 – 0.135 – 4.747 0.876 1.190 – 0.479 0.243 0.137 – 0.064 0.035 1.232 2.119 0.850 0.428 0.242 0.111 0.059 14.369 5.193 3.605 – 1.452 0.735 0.379 – 0.163 0.091 6.765 5.391 2.167 1.092 0.558 0.235 0.127 16.504 5.263 – – – 0.846 – – – 0.106 – – – – – – – 8.984 2.003 – – – 0.471 – – – 0.069 – – – – – – – Note: Accuracies are valid for measurements following an internal calibration. Measurement accuracies are listed for operational temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or factory-calibration temperature. One-year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage (for example, 10 V for the ±10 V range) after one year, assuming 100 pt averaging of data.*Smallest detectable voltage change in the input signal at the smallest input range. Table 2. E Series Analog Input Absolute Accuracy Specifications Full-Featured E Series NI 6052E NI 6070E, NI 6071E Low-Cost E Series PCI-6036E PCI-6024E, NI 6025E, Basic NI 6013, NI 6014 Models Nominal Range (V) Positive FS Negative FS 10 -10 10 0 NI 6030E, NI 6031E, NI 6032E, NI 6033E NI 6040E 1.43 1.201 1.405 1.176 8.127 5.685 Absolute Accuracy (mV) 8.127 2.417 5.685 – Data Acquisition and Signal Conditioning 8.127 – 3.835 – Table 3. E Series Analog Output Absolute Accuracy Specifications Recommended Accessories Signal conditioning is required for sensor measurements or voltage inputs greater than 10 V. National Instruments SCXI is a versatile, high-performance signal conditioning platform, intended for highchannel-count applications. NI SCC products provide portable, flexible signal conditioning options on a per-channel basis. Both signal conditioning platforms are designed to increase the performance and reliability of your DAQ System, and are up to 10X more accurate than terminal blocks (please visit ni.com/sigcon for more details). Refer to the table below for more information: Sensor/Signals (>10 V) System Description DAQ Device High performance PCI-60xxE, PXI-60xxE, DAQPad-60xxE Low-cost, portable PCI-60xxE, PXI-60xxE, DAQPad-60xxE Signals (
NIPXI-6052E 价格&库存

很抱歉,暂时无法提供与“NIPXI-6052E”相匹配的价格&库存,您可以联系我们找货

免费人工找货