0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIPXI-8183RT

NIPXI-8183RT

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIPXI-8183RT - 850 MHz Intel Celeron Real-Time Embedded Controllers for PXI - National Instruments C...

  • 数据手册
  • 价格&库存
NIPXI-8183RT 数据手册
850 MHz Intel Celeron Real-Time Embedded Controllers for PXI NI PXI-8183 RT NEW! • 2-slot real-time controller • Intel Celeron processor (850 MHz single core) • 256 MB (1 x 256 MB DIMM) RAM (standard) • Execution target for NI LabVIEW Real-Time or LabWindows™/CVI Real-Time applications • Reliable and deterministic operation • Ethernet control of PXI • Watchdog timer • 21 kHz single PID loop rate, maximum Development System Requirements (Windows) • LabVIEW • LabVIEW Real-Time Module Or • LabWindows/CVI • LabWindows/CVI Real-Time Module Deployment Software (included) • LabVIEW Real-Time embedded software PXI System Configuration • Complete PXI system configuration at ni.com/pxiadvisor Overview National Instruments RT Series PXI embedded controllers deliver a flexible, rugged platform for your deterministic, real-time measurement and control applications. This 2-slot embedded controller features an 850 MHz Intel Celeron processor and offers an ideal low-cost platform for deploying PXI-based systems in real-time applications. You develop your LabVIEW application with the NI LabVIEW Real-Time Module on Windows and download the program to your PXI-8183 RT controller via Ethernet. The embedded code executes on a real-time OS; thus, you can use the powerful and flexible development tools of LabVIEW to build reliable, real-time solutions. LabVIEW Real-Time applications running on PXI systems achieve microsecond loop rates with only 3 to 4 ns of system jitter. These real-time measurement and control systems capitalize on the latest processors combined with the advanced timing, triggering, and I/O synchronization benefits of PXI. Furthermore, NI measurement services software extends the timing capabilities of PXI to deliver tight integration with LabVIEW Real-Time applications through operations such as hardware-timed software loops. Built-in LabVIEW libraries help you create applications with data acquisition, dynamic signal acquisition, motion control, image acquisition, reconfigurable I/O, and instrumentation. Communicate with peripheral devices through CAN, GPIB, Ethernet, or serial protocols. Use NI-VISA to integrate third-party PXI/CompactPCI modules in your application. In addition, the PXI-8183 RT controller includes an external SMB connection for use as a trigger input, output, or watchdog timer. Use the external SMB to pass trigger and timing signals into and out of the PXI trigger bus in your system. Intel Celeron Processor (850 MHz Single Core) 256 MB (1 x 256 MB) 512 MB (1 x 512 MB) 40 GB PATA Optional1 – ✔ ✔ ✔ 2 ✔ CPU RAM, standard RAM, maximum Storage, hard drive (minimum) Storage, solid state Extended temperature and 24/7 operation option 10/100BASE-TX Fast Ethernet Serial port (RS232) Parallel port USB ports (v1.1) Watchdog/trigger SMB 1 Optional 512 or 128 MB solid-state drive can replace the hard drive. Connect to Any I/O The modularity of PXI and open development environment of LabVIEW make it easy to integrate a variety of I/O within your application. Create a custom real-time embedded solution using a PXI-8183 RT embedded controller with any number and combination of PXI/CompactPCI plug-in modules. Table 1. PXI-8183 RT Features 850 MHz Intel Celeron Real-Time Embedded Controllers for PXI Loop Rates (kHz) PXI-8183 RT 21.7 9.7 5.5 3.4 Create Reliable Stand-Alone Systems To ensure reliable operation, embedded LabVIEW Real-Time applications continue to run even if the host PC is interrupted or rebooted. Because the PXI-8183 RT embedded controller runs in a separate chassis with a dedicated power supply, the operator can shut down the host computer entirely without disrupting the real-time program. For stand-alone operation, you can embed code in the system so that it starts automatically when the system boots, requiring no human interaction. Use the LabVIEW Professional Development System and LabVIEW Real-Time Module to compile your LabVIEW application into an executable and download it to your PXI-8183 RT controller. Benchmark Analog input and output Analog input and output Analog input and output Analog input and output Processing PID PID PID PID Channels DAQ I/O Mode 1 1 16 16 Polling Interrupts Polling Interrupts Table 2. Maximum loop rates for LabVIEW Real-Time PXI systems are shown. All benchmarks use the LabVIEW 8.5 Real-Time Module with NI-DAQmx 8.7. These benchmarks do not test network performance and run on a headless target without a direct Ethernet connection for maximum performance. Visit ni.com or contact National Instruments for additional benchmarks. Dual-Boot Option You can configure NI PXI embedded controllers to boot into Windows or the real-time OS. NI Measurement & Automation Explorer (MAX) includes features for installing and configuring PXI embedded controllers as LabVIEW Real-Time targets. The controllers use a hardware switch or BIOS setting to boot into the desired OS. The result is a PXI embedded controller that can run embedded LabVIEW Real-Time or Windows applications. When the controller is in real-time mode, you need another Windows computer to develop and debug the LabVIEW Real-Time code for the PXI controller. To enable a Windows PXI embedded controller to dual-boot with the real-time OS, you must purchase the LabVIEW Real-Time embedded deployment software for the controller. Ordering Information To order a complete PXI system based on a LabVIEW Real-Time embedded controller, visit ni.com/pxiadvisor. Controller NI PXI-8183 RT ......................................................................780343-33 Memory Upgrades Standard 256 MB (1 x 256 MB DIMM) Recommended upgraded memory configurations: 512 MB (1 x 512 MB DIMM must be purchased) 512 MB SDRAM ..................................................................778469-512 Solid-State Storage Options 128 MB solid-state HDD ....................................................779175-128 512 MB solid-state HDD ....................................................779175-512 Accessories Parallel port adapter cable (6 in.)..........................................777169-01 NI MKD-1117 (rack-mount 1U LCD monitor, keyboard, mouse drawer) .................................................779872-01 NI PXI-8232, combo gigabit Ethernet and GPIB, NI-488.2....778658-01 NI PXI-8252 IEEE 1394 interface module ..............................778925-01 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/pxi. B U Y O NL IN E a t n i. co m o r C A L L 8 0 0 8 1 3 3 6 9 3 (U .S .) 2 850 MHz Intel Celeron Real-Time Embedded Controllers for PXI Specifications subject to change without notice. Random vibration Operating ........................................ 5 to 500 Hz, 0.3 grms (with solid-state hard drive) Nonoperating .................................. 5 to 500 Hz, 2.4 grms (tested in accordance with IEC-60068-2-64; nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3) Features Processor ............................................. 850 MHz Intel Celeron System memory (RAM) ....................... 256 MB, 7.5 ns SDRAM (standard) 512 MB, 7.5 ns SDRAM (maximum) Ethernet ............................................... 10/100BASE-TX, RJ45 connector Hard drive ............................................ 40 GB minimum, internal 2.5 in., 9.5 mm Fast Ultra ATA100 Interface Serial ................................................... 1 (RS232) Parallel ................................................ IEEE 1284, Type C Connector USB .................................................... 2 x USB 1.1 Safety and Compliance Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Power Requirements Current Voltage (V) +3.3 +5 +12 -12 Typical 3.0 4.5 0.01 0.0 Maximum 4.0 6.0 0.04 0.0 Physical Board dimensions ............................... 2-slot 3U PXI Express module Slot requirements ............................... 1 system slot plus 1 controller expansion slot (to the left of the system slot) Compatibility ....................................... Fully compatible with PXI specification Weight................................................. 0.82 kg (1.8 lb) typical Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: • EN 61326 EMC requirements; Minimum Immunity • EN 55011 Emissions; Group 1, Class A • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note: For EMC compliance, operate this device according to product documentation. Operating Environment Ambient temperature range1 .............. 5 to 50 °C2, 3 (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range ...................... 10 to 90%, noncondensing (tested in accordance with IEC-60068-2-56) 1 For CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. chassis not available in the online catalog at ni.com, please contact National Instruments for supported operating temperatures. to 50 °C for NI PXI-1036 Revision D and later, and NI PXI-1036DC Revision C and later. to 40 °C for NI PXI-1036 revisions B and C and NI PXI-1036DC Revision B. 25 35 Storage Environment Ambient temperature range ............... -40 to 65 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range ...................... 5 to 95% noncondensing (tested in accordance with IEC-60068-2-56) Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. Shock and Vibration Operating shock .................................. 30 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27; test profile developed in accordance with MIL-PRF-28800F) B U Y O NL IN E a t n i. co m o r C A L L 8 0 0 8 1 3 3 6 9 3 (U .S .) 3 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National I n s t ru ents Alliance m Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • 800 813 3693 National Instruments • info@ni.com *351592A-01* 351592A-01 2008-9477-501-101-D ©20 08 N ati onal In strum ents Corp oratio n. All right s reserv ed. CVI, La bVIEW, N ati onal In strum ents , Nat iona l I nstru ment s Al lia nce Partner, NI, n i.co m, and SCXI are tradem arks o f Na tion al Ins trumen ts. Th e m ark Lab Wi ndow s is us ed u nder a lice nse from Mic rosof t Co rp orati on. W indo ws is a registere d tra dema rk o f Mic roso ft Co rp orati on in the Un ited Sta tes and othe r co untrie s. Other produ ct a nd comp any na mes li ste d a re trad ema rk s or tra de name s of t heir resp ecti ve com pani es. A N ati onal In strum ents All ian ce Partner is a bus ines s enti ty ind epen dent from N I a nd h as no age ncy, p artners hip , o r jo int-v entu re rel atio nsh ip with N I.
NIPXI-8183RT 价格&库存

很抱歉,暂时无法提供与“NIPXI-8183RT”相匹配的价格&库存,您可以联系我们找货

免费人工找货