32-Channel (2-Wire), 300 V Multiplexer Switches
NI PXI-2527, NI PXIe-2527 NEW!
■
■
■
■
■
■
■
■
64x1 1-wire, 32x1 2-wire, or 16x1 4-wire multiplexer Maximum switch capacity Up to 300 VDC/300 VAC, CAT I Up to 2 A switching/2 A carry Up to 60 W or 62.5 VA Onboard relay counting 140 cycles/s Fully software programmable Deterministic operation with hardware triggers 32,000-step scan list Available in both PXI and PXI Express versions for optimal slot placement
■ ■ ■
Operating Systems Windows XP/2000/NT
■
Recommended Software LabVIEW LabWindows™/CVI Measurement Studio for Visual C++ NI Switch Executive
■ ■ ■ ■
Other Compatible Software Visual Basic ANSI C/C++
■ ■
Driver/Measurement Services Software (included) NI-SWITCH NI-DAQmx
■ ■
Compliance UL CE
■ ■
Overview and Applications
The NI PXI-2527 and PXIe-2527 are high-voltage multiplexer switch modules designed for medium- to high-density automated test systems. With a switching capacity of up to 300 VDC/300 VAC and up to 2 A, an NI 2527 acts as an effective front end for NI 4070 and NI 4072 digital multimeters (DMMs), offering simple channel expansion for voltage, current, resistance, capacitance, or inductance measurements. NI provides multiple-channel configurations including 64x1 one-wire, 32x1 two-wire, and 16x1 four-wire. Each channel, using robust electromechanical relays, is capable of scanning up to 140 channels/s. A cold-junction compensation (CJC) sensor is also included in the front-mounting terminal block to assist in thermocouple scanning applications.
Relay Count Tracking
These switch modules count relay closures on each of their relays. Relay counts are incremented each time a relay is actuated. You can retrieve the counts, stored on board the modules, programmatically and use them for predictive maintenance to reduce unexpected system downtime.
Simplified Signal Connectivity
Make signal connections for the NI 2527 modules in the TB-2627 front-mounting screw-terminal block. Additionally, to simplify connectivity with a DMM, use the HV6-BAN4 cable, which connects the banana jack inputs of a DMM to the COMs of each multiplexer bank.
Software
All National Instruments PXI switch modules are shipped with NI-SWITCH, an IVI-compliant driver that offers complete functionality for all switch modules. For additional assistance in configuring, programming, and managing higherchannel-count switching systems, NI Switch Executive software provides an easy-to-use, intelligent switch management and visual routing environment. Use the NI-SWITCH soft front panel for simple relay operations or debugging switch code/execution.
Automatic Scanning
NI 2527 switches are able to maximize throughput in automated test applications with the use of scanning. Scanning improves throughput by downloading a list of up to 32,000 connections to the switches and cycling through the list using an event (trigger) without any interruption from the host processor. You can most efficiently implement scanning by mating an NI 2527 with an instrument such as an NI 407x FlexDMM, which issues a trigger after each measurement.
32-Channel (2-Wire), 300 V Multiplexer Switches
Ordering Information
NI PXI-2527 ................................................................................... 778572-27 NI PXIe-2527 .................................................................................. 780587-27
Includes NI-SWITCH driver software.
Accessories TB-2627 terminal block ................................................................. 779358-01 HV6-BAN4 DMM connectivity cable ...........................................192795-0R2 NI Switch Executive Development system...................................................................... 778546-01 Deployment engine ........................................................................ 778548-00
BUY NOW
For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/switches.
Safety Compliance
■ ■
IEC 61010-1, EN 61010-1 UL 61010-01, CSA 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions
■ ■ ■ ■ ■
Note: For EMC compliance, operate this product according to the documentation.
CE Compliance
This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety)
■
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
32-Channel (2-Wire), 300 V Multiplexer Switches Specifications
Specifications subject to change without notice. Visit ni.com/manuals for the latest full specifications.
Dynamic Characteristics
Maximum speed.................................... Relay operate time Typical ............................................... Maximum .......................................... 300 V, CAT I 300 V 2A 60 W, 62.5 VA Refer to Figure 1 Expected relay life Mechanical ....................................... Electrical 25 MHz 2.5 V