NISCXI-1190 数据手册
1.3 GHz and 4 GHz Multiplexers 1.3 GHz and 4 GHz Multiplexers NI SCXI-1190, NI PXI-2590, NI SCXI-1191, NI PXI-2591 • 4x1 unterminated multiplexer • 50 characteristic impedance • High-bandwidth electromechanical relays • Excellent insertion loss, VSWR, and isolation specifications • Fully software programmable Operating Systems • Windows 2000/NT/XP Recommended Software • LabVIEW • LabVIEW Real-Time Module (PXI Modules only) • LabWindows/CVI • Measurement Studio • NI Switch Executive SCXI-1190 (quad 4x1), PXI-2590 (single 4x1) • 1.3 GHz bandwidth • SMB direct connectivity • 1 A at 24 VDC capacity Other Compatible Software • Visual Basic • C/C++ SCXI-1191 (quad 4x1), PXI-2591 (single 4x1) • 4 GHz bandwidth • SMA direct connectivity • 330 mA at 30 VDC capacity Driver Software (included) • NI-SWITCH Compliance • CE Overview The National Instruments PXI-2590 and PXI-2591 are 4x1 highfrequency unterminated multiplexing switches. The NI SCXI-1190 and NI SCXI-1191 perform the same functions as the PXI-2590 and PXI-2591 but also offer a quad 4x1 multiplexing configuration. The switches are capable of switching signals from DC to 1.3 GHz (SCXI-1190 and PXI-2590) and DC to 4 GHz (SCXI-1191 and PXI-2591). The characteristic impedance of the channels is 50 . For the SCXI-1190 and the PXI-2590, the maximum voltage rating of the switches is 24 Vrms with a maximum current of 1 A. For the SCXI-1191 and the PXI-2591, the maximum voltage rating is 30 Vrms with a maximum current of 330 mA. All are well suited for applications that require the routing of high-frequency signals inside automated test equipment (ATE) systems because they can switch signals with a very low insertion loss. In addition, the excellent voltage standing-wave ratio (VSWR) and isolation parameters make these modules the perfect choice in a system geared to highfrequency applications as shown in Table 1. Ordering Information NI SCXI-1190 ................................................................776572-90 NI PXI-2590 ..................................................................777987-01 NI SCXI-1191 ................................................................776572-91 NI PXI-2591 ..................................................................778339-01 Includes switch module and NI-SWITCH driver software. For information on extended warranty and value added services, see page 20. See page 499 for accessory and cable information. BUY ONLINE! Visit ni.com/products and enter pxi2590, pxi2591, scxi1190, and/or scxi1191. Module SCXI-1190, PXI-2590 (@ 1.3 GHz) SCXI-1190, PXI-2590 (@ 2 GHz) SCXI-1191, PXI-2591 (@ 4 GHz) Insertion Loss < 1.5 dB < 3 dB < 0.9 dB VSWR < 1.5 < 2.5 < 1.5 Switches Table 1. Parameters of High-Frequency Switching Modules Extended Features and Specifications National Instruments switch modules are built with a number of core features that are covered in detail in the Switch Overview section. For additional information about the PXI-2590, PXI-2591, SCXI-1190, and SCXI-1191, including software, certifications and compliance, relay control, etc., please see page 20. For detailed specifications, please see page 504. 492 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com Switch Specifications Specifications Specifications (continued) 2 1.9 1.8 1.7 1.6 VSWR 1.5 8x1 1.4 1.3 1.2 1.1 0 0 100 200 300 400 500 600 Frequency (MHz) 700 800 900 1000 16x1 32x1 SCXI-1190, PXI-2590 Input Characteristics Number of channels per bank.......................... Number of banks SCXI-1190 .................................................. PXI-2590..................................................... Input voltage Channel-to-earth........................................ Maximum switching voltage AC ............................................................ DC ............................................................ Maximum switching capacity per channel AC ............................................................ DC ............................................................ Maximum switching power per channel ......... Contact resistance (initial) ............................... Contact material............................................... 4 4 1 24 VDC 24 Vrms 24 VDC 1 Arms at 24 Vrms 1 A at 24 VDC 24 W 100 mΩ maximum Gold-clad silver Input Characteristics Maximum switching voltage............................ Maximum switching current ............................ Maximum carry current.................................... Simultaneous channels at maximum current PXI-2593 ................................................... SCXI-1193 .................................................. DC path resistance Initial ......................................................... End of life .................................................. 150 V, CAT I 0.5 A (per channel) 1 A (per channel) 2, maximum 4, maximum
NISCXI-1190
1. 物料型号: - NI SCXI-1190:1.3 GHz带宽的4x1未终止多路复用开关。 - NI PXI-2590:与SCXI-1190功能相同,但是单4x1配置。 - NI SCXI-1191:4 GHz带宽的4x1未终止多路复用开关。 - NI PXI-2591:与SCXI-1191功能相同,但是单4x1配置。

2. 器件简介: - 这些开关能够处理从直流到1.3 GHz或4 GHz的信号,适用于需要高频信号路由的自动测试设备系统。

3. 引脚分配: - 输入通道数每组为4个,对于SCXI-1190和PXI-2590有4组,SCXI-1191和PXI-2591也是类似配置。 - I/O连接器:PXI-2593和SCXI-1193有18个MCX插座,2个SMB插座。

4. 参数特性: - 特性阻抗(Z0):50欧姆。 - 插入损耗:1.3GHz时<1.5dB,4GHz时<0.9dB。 - 电压驻波比(VSWR):1.3GHz时<1.5,4GHz时<1.5。

5. 功能详解: - 这些模块是完全软件可编程的,使用高带宽的机电继电器,具有出色的插入损耗、VSWR和隔离规格。

6. 应用信息: - 适用于需要在ATE系统中路由高频信号的应用场合。

7. 封装信息: - PXI-2593和SCXI-1193的尺寸为10 by 16 by 4 cm(3.9 by 6.3 by 1.6 in.)。 - SCXI-1190和PXI-2590的尺寸为17.3 by 19.6 by 3.0 cm(6.81 by 7.70 by 1.19 in.)。