0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NIUSB-6525

NIUSB-6525

  • 厂商:

    NI

  • 封装:

  • 描述:

    NIUSB-6525 - Small, portable digital I/O device / Eight channel-to-channel optically isolated inputs...

  • 数据手册
  • 价格&库存
NIUSB-6525 数据手册
Industrial Digital I/O Device for USB – 60 V, Channel-to-Channel Isolated NI USB-6525 • Small, portable digital I/O device • Eight channel-to-channel optically isolated inputs (±60 VDC) • Eight channel-to-channel optically isolated, solid-state relay outputs (60 VDC/30 Vrms max) • 500 mA maximum switching current per channel • One 32-bit event counter • Full-speed USB (12 Mb/s) bus interface • Built-in, removable connectors for easy connectivity • USB cable strain relief Operating Systems • Windows Vista/XP/2000 Recommended Software • • • • LabVIEW LabWindows™/CVI Measurement Studio LabVIEW SignalExpress Other Compatible Software • Visual Studio .NET • C, C++ • Visual Basic Measurement Services Software (included) • NI-DAQmx driver software • Measurement & Automation Explorer configuration utility • LabVIEW SignalExpress LE data-logging software Product NI USB-6525 Digital Inputs 8 Low Threshold 1 VDC High Threshold 3.2 VDC Input Current 3 mA/ch SSR Outputs 8 Switching Current 500 mA Max Signal Range ±60 VDC Isolation Ch-to-Ch 32-Bit Counters 1 Table 1. NI USB-6525 Specifications Overview Overview and Applications The National Instruments USB-6525 is a full-speed USB device with eight normally open, channel-to-channel isolated, solid-state relay outputs and eight ±60 VDC channel-to-channel isolated digital inputs. The NI USB-6525 offers features for industrial control and manufacturing test applications, such as factory automation, embedded machine control, and production line verification. The solid-state relay outputs have a 60 VDC/30 Vrms switching voltage and 500 mA/ch maximum switching current, making them ideal for controlling pumps, valves, motors, and other industrial actuators. The eight isolated digital input channels break ground loops and offer protection from noise and spikes on external signals. You can also use one of the digital input channels as a 5 kHz, 32-bit event counter for counting digital pulses. PFI 0 (an alias to P1.7) can also function as the source for a 32-bit counter. In this mode, the device counts low to high transitions on P1.7. You can arm and disarm the counter as well as read or reset the count through software. You can connect loads to the solid-state relay outputs with an AC or DC power source. The default power-on state of the solid-state relays is open. The relays also remain open when the computer and the USB-6525 device are powered off. Module Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Signal P0.0A P0.0B P0.1A P0.1B P0.2A P0.2B P0.3A P0.3B P0.4A P0.4B P0.5A P0.5B P0.6A P0.6B P0.7A P0.7B Module Terminal 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Signal P1.0+ P1.0P1.1+ P1.1P1.2+ P1.2P1.3+ P1.3P1.4+ P1.4P1.5+ P1.5P1.6+ P1.6P1.7+/PFI 0+ P1.7-/PFI 0- Hardware The USB-6525 has eight channel-to-channel optically isolated inputs, P1., and eight channel-to-channel optically isolated, solid-state relay outputs, P0.. The isolated inputs consist of an optocoupler, a depletion-mode MOSFET-based current-limiting circuit, and a Schottky diode. Each channel has its own positive and negative terminals capable of detecting a wide range of DC signals, from 5 V TTL logic levels to DC power supply levels up to 60 V. Table 2. NI USB-6525 Pinout Industrial Digital I/O Device for USB – 60 V, Channel-to-Channel Isolated Isolation Isolation is a form of built-in signal conditioning that provides an extended voltage range for direct connectivity to industrial sensors and actuators. The USB-6525 provides channel-to-channel isolation where each channel is physically and electrically separated from the others. Isolation provides three main benefits: 1. Safety from hazardous high voltages and transients 2. Rejection of common-mode voltages 3. Removal of ground loops Software National Instruments measurement services software, built around NI-DAQmx driver software, includes intuitive application programming interfaces, configuration tools, I/O assistants, and other tools designed to reduce system setup, configuration, and development time. National Instruments recommends using the latest version of NI-DAQmx driver software for application development in National Instruments LabVIEW, LabWindows/CVI, and Measurement Studio. To obtain the latest version of NI-DAQmx, visit ni.com/support/daq/versions. NI measurement services software speeds up your development with features including: • A guide to create fast and accurate measurements with no programming using DAQ Assistant • Automatic code generation to create your application in LabVIEW; LabWindows/CVI; LabVIEW SignalExpress; and Visual Studio .NET, C/C++/C#, or Visual Basic using Measurement Studio • Multithreaded streaming technology • More than 3,000 free software downloads to jump-start your project available at ni.com/zone • Software configuration of all digital I/O features without hardware switches/jumpers • Free LabVIEW SignalExpress LE data-logging software The USB-6525 is compatible with the following versions (or later) of NI application software – LabVIEW, LabWindows/CVI, and Measurement Studio versions 7.x or LabVIEW SignalExpress. You can also use your NI digital I/O device with ANSI C, Microsoft Visual C++, Visual Basic, and the Microsoft .NET languages C# and Visual Basic .NET. The USB-6525 is not compatible with the Traditional NI-DAQ (Legacy) driver. Safety from High-Voltage Transients Isolation electrically separates high-voltage front-end channels from each other and the low-voltage back end of the USB-6525. Signals are passed between the two sections of the device using optocouplers. By separating the two sections, any voltages within the isolation specifications are prevented from entering the USB bus section or other channels. Isolation provides protection for the user, data acquisition system, and measurement data. Common-Mode Voltage Rejection A voltage common to both sides of a differential circuit pair is called common-mode voltage. This phenomenon is typical in noisy environments containing machinery and inductive loads. The differential voltage across the circuit pair is the desired signal, whereas the common voltage signal is the unwanted signal that may have been coupled into the transmission line. The USB-6525 can measure signals from lines with signal plus common-mode voltage of up to 60 VDC. Ground Loop Removal Ground loops are the most common source of noise in data acquisition applications. They occur when two connected terminals in a circuit are at different ground potentials, causing current to flow between the two points. This additional voltage can cause significant error in the measurement. When a ground loop exists, the measured voltage is the sum of the signal voltage and the potential difference that exists between the signal source ground and the measurement system ground. This potential is generally not a DC level; therefore, the result is a noisy measurement system. By offering an isolated floating ground on the front end, the isolated USB-6525 devices are able to prevent ground loops from forming. Ordering Information NI USB-6525 ..........................................................................779640-01 Includes NI-DAQmx software, LabVIEW SignalExpress LE data-logging software, and a USB cable. NI USB-6000 Series Prototyping Accessory ........................779511-01 Includes breadboarding area with cover and strain relief. BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/usb. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 2 Industrial Digital I/O Device for USB – 60 V, Channel-to-Channel Isolated Specifications These specifications are typical at 25 °C, unless otherwise noted. Isolated Inputs Number of channels............................ 8, ch-ch isolated Input voltage range............................. -60 to 60 VDC Screw-terminal wiring ........................ 16 to 28 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end Torque for screw terminals................. 0.22 to 0.25 N · m (2.0 to 2.2 lb in.) Weight With connectors ............................. Approx. 87 g (3.1 oz) Without connectors ........................ Approx. 64 g (2.3 oz) Max 1 VDC 60 VDC Digital logic levels Level Input low voltage Input high voltage Min -60 VDC 3.2 VDC Isolation Channel-to-channel ............................ 60 VDC continuous Channel-to-earth ground .................... 60 VDC continuous Withstand .......................................... 60 VDC continuous Note: Do not use this module for connection to signals or for measurements within Measurement Categories II, III, or IV. Input current........................................ 3.0 mA/channel max Solid-State Relay Outputs Number of channels............................ 8, ch-ch isolated Relay type ........................................... Normally open solid-state relay (SSR) Switching voltage ............................... 60 VDC/30 Vrms max Switching current (per channel) ......... 500 mA max, full operation temperature range Switching rate (90% duty cycle)......... 5 operations per second Relay open time .................................. 60 µs typ Relay close time.................................. 1.2 ms typ On-resistance ...................................... 550 mΩ, max Off-leakage current (max) ................... 0.6 µA typ Environment NI 6528 and PXI-6529 devices are intended for indoor use only. Pollution degree (IEC-60664) ............. 2 Operating Environment Ambient temperature ......................... 0 to 55 °C Relative humidity ................................ 10 to 90%, noncondensing Maximum altitude .............................. 2,000 m at 25 °C ambient temperature (tested in accordance with IEC-60068-2-1, IEC-60068-2-2, and IEC-60068-2-56) Counter Number of counters ............................ 1 (P1.7 can be configured as a counter) Resolution ........................................... 32 bits Counter measurements....................... rising edge counting Maximum input frequency.................. 5 kHz Minimum high pulse width................. 20 µs Minimum low pulse width.................. 180 µs Storage Environment Ambient temperature ......................... -40 to 85 °C Relative humidity ............................... 5% to 95%, noncondensing (tested in accordance with IEC-60068-2-1, IEC-60068-2-2, and IEC-60068-2-56) Safety and Compliance Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Bus Interface USB specification................................ USB 2.0 full-speed (12 Mb/s) Power Requirements Input voltage ....................................... 4.5 to 5.25 VDC in configured state Active current...................................... 150 mA max Suspend current.................................. 350 µA typ Physical Characteristics Dimensions Without connectors ........................ 6.35 by 8.51 by 2.31 cm (2.50 by 3.35 by 0.91 in.) With connectors ............................. 8.18 by 8.51 by 2.31 cm (3.22 by 3.35 by 0.91 in.) I/O connectors..................................... USB series B receptacle, (2) 16 position (screw terminal) plug headers Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: • EN 61326 EMC requirements; Minimum Immunity • EN 55011 Emissions; Group 1, Class A • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note: For EMC compliance, operate this device according to product documentation. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 3 Industrial Digital I/O Device for USB – 60 V, Channel-to-Channel Isolated CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 73/23/EEC; Low-Voltage Directive (safety) • 89/336/EEC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 4 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • 800 813 3693 National Instruments • info@ni.com *351494A-01* 351494A-01 2007-8768-301-101-D © 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
NIUSB-6525 价格&库存

很抱歉,暂时无法提供与“NIUSB-6525”相匹配的价格&库存,您可以联系我们找货

免费人工找货