0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PXI-2576

PXI-2576

  • 厂商:

    NI

  • 封装:

  • 描述:

    PXI-2576 - 16 4x1 (2-wire), octal 8x1 (2-wire),quad 16x1 (2-wire), dual 32x1 (2-wire),64x1 (2-wire) ...

  • 数据手册
  • 价格&库存
PXI-2576 数据手册
64-Channel Multibank Multiplexer NI PXI-2576 NEW! • 16 4x1 (2-wire), octal 8x1 (2-wire), quad 16x1 (2-wire), dual 32x1 (2-wire), 64x1 (2-wire) • Up to 100 VDC/100 VAC • Up to 1 A switching • Up to 30 W, 37.5 VA • Full software programmability • Onboard relay count tracking for predictive maintenance • 145 channels/s Operating Systems • Windows 2000/NT/XP • Linux® Recommended Software • • • • • NI Switch Executive LabVIEW LabVIEW Real-Time Module LabWindows/CVI Measurement Studio Other Compatible Software • Visual Basic • C/C++ Driver/Services Software (included) • NI-SWITCH • NI-DAQmx Overview The National Instruments PXI-2576 is a multibank multiplexing module with 16 banks of 4x1 2-wire multiplexers. With the flexible architecture of the NI PXI-2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low-channel counts. In addition, you can combine all multiplexers on the PXI-2576 to form a single high-channel-count multiplexer featuring 64 2-wire channels. The module can be programmed with a variety of software including NI-SWITCH and NI Switch Executive. Software All National Instruments PXI switch modules are shipped with NI-SWITCH, an IVI-compliant driver offering complete functionality for all switch modules. For additional assistance in configuring, programming, and managing higher-channel-count switching systems, NI Switch Executive software offers an easy-to-use, intelligent switch management and visual routing environment. Use the NI-SWITCH Soft Front Panel for simple relay operations or debugging switch code/execution. Automatic Scanning The PXI-2576 maximizes throughput in automated test applications using scanning. Scanning improves throughput by downloading a list of up to 32,000 connections to the switch and cycling through the list using an event (trigger) without any interruption from the host processor. Scanning is most efficiently accomplished by mating the PXI-2576 with an instrument, such as the NI PXI-4070 6 1⁄2 -digit FlexDMM, which issues a trigger after each measurement. Ordering Information NI PXI-2576............................................................................778572-76 Includes NI-SWITCH and NI-DAQmx driver software. Relay Count Tracking The PXI-2576 counts relay closures on each relay. Relay counts are incremented each time a relay is actuated. You can retrieve the counts, stored on board the module, programmatically and use them for predictive maintenance to reduce unexpected system downtime. Accessories NI TB-2676 terminal block ....................................................779535-01 NI Switch Executive Development System ........................................................778546-01 Deployment Engine ..........................................................778548-00 BUY NOW! For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/switches. 64-Channel Multibank Multiplexer Figure 1. NI PXI-2576 Multibank Multiplexer Topology BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.) 2 64-Channel Multibank Multiplexer Physical Characteristics Relay type ........................................... Electromechanical, latching I/O connectors..................................... LFH Matrix 50, 160 positions, male Dimensions.......................................... single-slot PXI, 3U Weight................................................. 300 g (12 oz) Specifications All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Configurations..................................... Sixteen 4x 1, 2-wire multiplexers; Octal 8x 1, 2-wire multiplexers; Quad 16x 1, 2-wire multiplexers; Dual 32x 1, 2-wire multiplexers; 64x 1, 2-wire multiplexer Environment Operating temperature ....................... Storage temperature........................... Relative humidity ................................ Pollution degree.................................. Approved at altitudes up to 2,000 m. Indoor use only. Input Characteristics All input characteristics are VDC, Vrms, or a combination unless otherwise specified. Maximum switching voltage Channel-to-channel ........................ Channel-to-ground.......................... Maximum switching current............... Maximum carry current....................... Maximum switching power ................ DC path resistance Initial............................................... End of life ....................................... Thermal emf........................................ Typical bandwidth (50 Ω system) 4x1, 8x1 configurations .................. 16x1 configuration.......................... 32x1 configuration.......................... 64x1 configuration.......................... (100 Ω system) 4x1, 8x1 configurations .................. 16x1 configuration.......................... 32x1 configuration.......................... 64x1 configuration.......................... Typical bank-to-bank crosstalk (50 or 100 Ω system, 4x1 configuration) 100 kHz ........................................... 40 dB >30 MHz >20 MHz >15 MHz >10 MHz >60 MHz >40 MHz >20 MHz >10 MHz 100 V 100 V, CAT I 1A 1A 30 W, 37.5 VA
PXI-2576 价格&库存

很抱歉,暂时无法提供与“PXI-2576”相匹配的价格&库存,您可以联系我们找货

免费人工找货