12-Channel, 300 V CAT II, 600 V CAT I Multiplexer
NI PXI-2584 NEW!
• Dual 6x1 1-wire, 12x1 1-wire, 6x1 2-wire, interleaved 11x1 2-wire multiplexer configuration • Switching capacity • Up to 300 V CAT II, 600 V CAT I • Up to 0.5 A switching/0.5 A carry • Up to 10 W • 600 channels/s • Onboard relay counting • Fully software programmable • 32,000-step scanlist for deterministic scanning • Tight synchronization with instruments through hardware triggers
Operating Systems
• Windows 2000/XP • Linux®
Recommended Software
• • • • NI Switch Executive LabVIEW LabWindows/CVI Measurement Studio
Other Compatible Software
• Visual Basic • C/C++
Driver Software (included)
• NI-SWITCH • NI-DAQmx
Overview
The National Instruments PXI-2584 is a high-voltage multiplexer switch in a single-slot, 3U PXI module. With a CAT II certification at 300 V, it is capable of routing general-purpose ATE loads or high-voltage, low-current signals. The 600 V CAT I channel-to-ground isolation on the NI PXI-2584 makes it ideal for fuel cell and battery stack applications. You also can use the module in multimodule configurations for taking measurements on hundreds of channels. The CAT I and CAT II safety ratings combined with UL safety certification make it ideally suited for high-voltage ATE systems that include the NI PXI-4071 1000 V digital multimeter. The reed relays in the PXI-2584 also ensure longer lifetimes and faster actuation times for test equipment.
Interleaved Topology for Maximum Channel Count
Interleaved topology is a method to increase channel count when measuring potentials that are on a stack such as battery stacks and fuel cell stacks. In traditional 2-wire topologies, each channel would put two wires across each component under test, which would limit the PXI-2584 to six differential channels. By putting each single input pin on the front connector at points in between potentials on a stack, the channel count is extended from six to 11 2-wire channels. In addition to maximizing channel count on a module, the topology offers a free “straddle” channel when testing battery stacks over multiple modules.
The PXI-2584 Interleaved Topology Maximizes Channel Count
12-Channel, 300 V CAT II, 600 V CAT I Multiplexer
Relay Count Tracking
The PXI-2584 counts relay closures on each of its high-voltage relays. Relay counts are incremented each time a relay is actuated. The counts, stored onboard the module, are retrievable programmatically and can be used for predictive maintenance to reduce unexpected system downtime.
Specifications
Relay Characteristics
Configurations..................................... Dual 6x1 1-wire, 12x1 1-wire, 6x1 2-wire, interleaved 11x1 2-wire (battery test) Contact materials................................ Rhodium Maximum switching voltage AC ................................................... 600 VACpk DC ................................................... 600 VDC Maximum switching current............... 0.5 A Maximum carry current....................... 0.5 A Maximum switching power ................ 10 W DC path resistance (1-wire path) Initial............................................... 2 Ω Minimum switching capacity.............. 0.5 V or 1 mA
Automatic Scanning
The PXI-2584 maximizes throughput in automated test applications by the use of scanning. Scanning improves throughput by downloading a list of up to 32,000 connections to the switch and cycling through the list using an event (trigger) without any interruption from the host processor. Scanning is most efficiently accomplished by mating the PXI-2584 with other instruments such as the PXI-4071 1000 V FlexDMM, which issues a trigger after each measurement is complete.
Dynamic Characteristics
Software
All National Instruments PXI switch modules are shipped with NI-SWITCH, an IVI-compliant driver offering complete functionality for all switch modules. For additional assistance in configuring, programming, and managing higher-channel-count switching systems, NI Switch Executive software offers an easy-to-use, intelligent switch management and visual routing environment. Use the NI-SWITCH Soft Front Panel for simple relay operations or debugging switch code/execution.
Maximum scan rate ............................ Relay operate time Typical ............................................. Maximum........................................ Expected relay life Mechanical (1 V at 10 mA resistive).............. 600 V at 7 mA 90 pF capacitive ................................... 600 V at 16.5 mA 90 pF capacitive ...................................
600 channels/s 0.4 ms 0.75 ms
3x108 cycles 1.8x107 cycles 7x106 cycle
Note: Certain applications may require additional time for proper settling. For information about including additional settling time, refer to the NI Switches Help.
Ordering Information
NI PXI-2584............................................................................778572-84 Accessories and Software Connector/Backshell Kit ........................................................779168-02 NI Switch Executive Development System ........................................................778546-01 Deployment Engine ..........................................................778548-00
Physical
Relay type ........................................... Reed I/O connector ...................................... 16 position, MINI-COMBICON plug Dimensions.......................................... Single PXI slot, 3U
Environment
Operating temperature ....................... Storage temperature........................... Relative humidity ................................ Pollution degree..................................
Approved at altitudes up to 2000 m. Indoor use only.
BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/switches.
0 to 55 °C -20 to 70 °C 5 to 85% noncondensing 2
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
2
12-Channel, 300 V CAT II, 600 V CAT I Multiplexer
Safety and Compliance
Safety
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CAN/CSA-C22.2 No. 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: • EN 61326 EMC requirements; Minimum Immunity • EMC unprotected
CE Compliance
This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 73/23/EEC; Low-Voltage Directive (safety) • 89/336/EEC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm.
BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp.
SERVICE NEEDS
Training and Certification
NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration.
OEM Support
We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com • (800) 813 3693
National Instruments • info@ni.com
*351377A-01*
351377A-01 2006-7267-101-D
© 2006 National Instruments Corporation. All rights reserved. CVI, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Linux ® is the registered trademark of Linus Torvalds in the U.S. and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.