0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PXI-2596

PXI-2596

  • 厂商:

    NI

  • 封装:

  • 描述:

    PXI-2596 - 26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches - National Instruments Corporat...

  • 数据手册
  • 价格&库存
PXI-2596 数据手册
26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches NI PXI-2596, NI PXI-2597, NI PXI-2598, NI PXI-2599 • 26.5 GHz bandwidth electromechanical relays • 50 characteristic impedance • Onboard relay counting • Fully software programmable • Configurations • PXI-2596 – dual 6x1 unterminated multiplexer (SP6T) • PXI-2597 – 6x1 terminated multiplexer (SP6T) • PXI-2598 – dual transfer switch • PXI-2599 – dual SPDT (Form C) relays • Modules designed using microwave relays from Radiall Operating Systems • Windows 2000/NT/XP Ω Recommended Software • • • • NI Switch Executive LabVIEW LabWindows/CVI Measurement Studio Other Compatible Software • Visual Basic • C/C++ Driver/Services Software (included) • NI-SWITCH • NI-DAQmx Overview and Applications The National Instruments PXI-2596, PXI-2597, PXI-2598, and PXI-2599 multiplexers, SPDT relays, and transfer switch modules route RF or microwave signals in automated test applications. While designed to operate with less than 1 dB insertion loss up to 26.5 GHz, they appear almost invisible to signals at much lower frequencies as well. Use the NI PXI-2597 terminated multiplexer when high-power signal reflections are a concern and 50 terminations are required. The PXI-2596 offers a higher-density, unterminated option with dual 6x1 multiplexer banks in the same module. The PXI-2598 and PXI-2599 operate as transfer switches and SPDT relays, respectively, for basic signal routing or inserting and removing components in a signal path. These modules are also well-suited for passing high-order harmonics from RF upconverters such as the NI PXI-5670 2.7 GHz RF vector signal generator or routing multiple sources to RF downconverters such as the NI PXI-5660 2.7 GHz RF vector signal analyzer. Software All National Instruments PXI switch modules are shipped with NI-SWITCH, an IVI-compliant driver offering complete functionality for all switch modules. For additional assistance in configuring, programming, and managing higher-channel-count switching systems, NI Switch Executive software offers an easy-to-use, intelligent switch management and visual routing environment. With the latest version of NI Switch Executive, you can store calibration information for your RF/microwave switch routes on a per-path basis. Use the NI-SWITCH Soft Front Panel for simple relay operations or debugging switch code/execution. Ω Ordering Information NI PXI-2596............................................................................778572-96 NI PXI-2597............................................................................778572-97 NI PXI-2598............................................................................778572-98 NI PXI-2599............................................................................778572-99 Includes NI-SWITCH and NI-DAQmx driver software. Relay Count Tracking The switches count relay closures on each of their individual relays. Relay counts are incremented each time a relay is actuated. You can programmatically retrieve the counts, stored on board the modules, and use them for predictive maintenance to reduce unexpected system downtime. Accessories SMA male-male cable (semirigid) 0.15 cm..........................................................................…763443-01 0.45 cm ..............................................................................763444-01 NI Switch Executive Development system ........................................................778546-01 Deployment engine ..........................................................778548-00 Signal Connectivity Options The PXI-2596, PXI-2597, PXI-2598, and PXI-2599 all use standard SMA connectors for signal connections. National Instruments offers two semirigid SMA cables (0.15 and 0.45 cm) that are acceptable for many RF/microwave signals. There are also many custom cable vendors on the market that can meet your exact cable length, performance, and connector requirements. Please visit ni.com/switches for a list of third-party cable vendors. BUY NOW! For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/switches. 26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches Dynamic Characteristics Expected relay life (mechanical) PXI-2596.......................................... PXI-2597.......................................... PXI-2598.......................................... PXI-2599.......................................... Recommended cycle speed ................ 107 cycles 2 x 106 cycles 2.5 x 106 cycles 107 cycles 5 cycles/s Specifications Input Characteristics Frequency range.................................. 0 to 26.5 GHz Characteristic Impedance ................... 50 Maximum RF carry power (50 load) PXI-2596, PXI-2597, PXI-2599............. 150 W PXI-2598.......................................... 75 W Maximum voltage (cold-switching only) PXI-2596, PXI-2597, PXI-2599............. 90 Vrms PXI-2598.......................................... 65 Vrms Maximum carry current (per channel) PXI-2596, PXI-2597, PXI-2599............. 1.73 Arms PXI-2598.......................................... 1.25 Arms Ω Ω Physical Relay manufacturer/PN PXI-2596.......................................... PXI-2597.......................................... PXI-2598.......................................... PXI-2599.......................................... Relay types.......................................... Contact material ................................. I/O connectors..................................... Dimensions PXI-2596.......................................... PXI-2597.......................................... PXI-2598.......................................... PXI-2599.......................................... Radiall R591 series Radiall R574 series Radiall R577 series Radiall R570 series Electromechanical Beryllium copper, gold-plated SMA jacks 2-slot, 3U, PXI/cPCI module 3-slot, 3U, PXI/cPCI module 2-slot, 3U, PXI/cPCI module 1-slot, 3U, PXI/cPCI module Insertion Loss (dB) Module PXI-2596 PXI-2597 PXI-2598 PXI-2599 0 to 3 0.2 0.2 0.2 0.2 3 to 8 0.3 0.3 0.3 0.3 Frequency (GHz) 8 to 12.4 12.4 to 18 0.4 0.5 0.4 0.5 0.4 0.5 0.4 0.5 18 to 26.5 0.6 0.7 0.7 0.7 Voltage Standing Wave Ratio (VSWR) Module PXI-2596 PXI-2597 PXI-2598 PXI-2599 0 to 3 1.2 1.2 1.2 1.2 3 to 8 1.3 1.3 1.3 1.3 Frequency (GHz) 8 to 12.4 12.4 to 18 1.4 1.5 1.4 1.5 1.4 1.5 1.4 1.5 18 to 26.5 1.6 1.7 1.7 1.7 Environment Operating temperature ....................... Storage temperature........................... Relative humidity ................................ Pollution degree.................................. Approved altitude ............................... Indoor use only. 0 to 55 °C -20 to 70 °C 5 to 85%, noncondensing 2 up to 2,000 m Open Channel Isolation (dB) Module PXI-2596 PXI-2597 PXI-2598 PXI-2599 0 to 3 80 80 80 80 3 to 8 70 70 70 70 Frequency (GHz) 8 to 12.4 12.4 to 18 60 60 60 60 65 60 60 60 18 to 26.5 55 55 50 55 Shock and Vibration Operational shock .................................. 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random vibration Operating ........................................ 5 to 500 Hz, 0.3 grms Nonoperating.................................. 5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) RF Carry Power (W) Module PXI-2596 PXI-2597 PXI-2598 PXI-2599 0 to 3 150 150 75 150 3 to 8 95 95 50 95 Frequency (GHz) 8 to 12.4 12.4 to 18 75 65 75 65 35 30 75 65 18 to 26.5 25 25 25 25 Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1 CAN/CSA-C22.2 No. 61010-1 PXI-2597 termination power, average (at 25 °C) Per termination ............................... 1 W Total ................................................ 3 W BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.) 2 26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches Electromagnetic Compatibility Emissions ............................................ EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity.............................................. EN 61326:1997 + A2:2001, Table 1 EMC/EMI............................................. CE, C-Tick, and FCC Part 15 (Class A) Compliant Note: For EMC compliance, operate these devices with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety) ........... 73/23/EEC Electromagnetic Compatibility Directive (EMC) ................................... 89/336/EEC Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. BUY ONLINE a t ni.com o r CALL (800) 813 3693 (U.S.) 3 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. SERVICE NEEDS Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 813 3693 National Instruments • info@ni.com *342572A-01* 342572A-01 2006-6497-101-D © 2006 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI-DAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
PXI-2596 价格&库存

很抱歉,暂时无法提供与“PXI-2596”相匹配的价格&库存,您可以联系我们找货

免费人工找货