0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PXI-8101RT

PXI-8101RT

  • 厂商:

    NI

  • 封装:

  • 描述:

    PXI-8101RT - 2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI - National Instruments...

  • 数据手册
  • 价格&库存
PXI-8101RT 数据手册
2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI NI PXI-8101 RT NEW! ◾◾ Intel Celeron 575 processor (2.0 GHz single core) ◾◾ 1 GB (1 x 1 GB DIMM) RAM (standard) ◾◾ 2 GB (1 x 2 GB DIMM) RAM (maximum) ◾◾ Execution target for NI LabVIEW Real-Time or LabWindows™/CVI Real-Time applications ◾◾ Reliable and deterministic operation ◾◾ Ethernet control of PXI ◾◾ Watchdog timer ◾◾ Up to 20 percent faster PID performance than PXI-8104 RT Development System Requirements (Windows) ◾◾ LabVIEW 8.6.1 or later ◾◾ LabVIEW Real-Time Module 8.6.1 or later Or ◾◾ LabWindows/CVI ◾◾ LabWindows/CVI Real-Time Module Deployment Software (included) ◾◾ OS and drivers already installed ◾◾ Hard-drive-based image recovery PXI System Configuration ◾◾ Complete PXI system configuration at ni.com/pxiadvisor Overview National Instruments RT Series PXI embedded controllers deliver a flexible, rugged platform for your deterministic, real-time measurement and control applications. The NI PXI-8101 RT controller with its 2.0 GHz single-core processor, 1 GB standard RAM, and 800 MHz DDR2 memory offers an ideal balance of performance and value for real-time test and control applications. You develop your LabVIEW application with the LabVIEW Real-Time Module on Windows and download the program to your PXI-8101 RT controller via Ethernet. The embedded code executes on a real-time OS. Thus, you use the powerful and flexible development tools of LabVIEW to build reliable, real-time solutions. LabVIEW Real-Time applications running on PXI systems achieve microsecond loop rates with only 3 to 4 ns of system jitter. These real-time measurement and control systems capitalize on Intel processors combined with the advanced timing, triggering, and I/O synchronization benefits of PXI. Furthermore, NI measurement services software extends the timing capabilities of PXI to deliver tight integration with LabVIEW Real-Time applications through operations such as hardware-timed software loops. I/O, and instrumentation. Communicate with peripheral devices through CAN, GPIB, Ethernet, or serial protocols. Use NI-VISA to integrate third-party PXI/CompactPCI modules in your application. In addition, the PXI-8101 RT controller includes an external SMB connection for use as a trigger input, output, or watchdog timer. Use the external SMB to pass trigger and timing signals into and out of the PXI trigger bus in your system. CPU 800 MHz DDR2 RAM, standard 800 MHz DDR2 RAM, maximum Storage, hard drive (minimum) Storage, solid state Extended temperature and 24/7 operation option 10/100/1000BASE-TX (Gigabit) Ethernet Serial port (RS232) Parallel port Hi-Speed USB ports Watchdog/trigger SMB 1 Intel Celeron 575 Processor (2.0 GHz Single Core) 1 GB (1 x 1 GB) 2 GB (1 x 2 GB) 80 GB SATA Optional1 – 4 4 4 2 4 Connect to Any I/O The modularity of PXI and open development environment of LabVIEW make it easy to integrate a variety of I/O within your application. Create a custom real-time embedded solution using a PXI-8101 RT embedded controller with any number and combination of PXI/CompactPCI plug-in modules. Built-in LabVIEW libraries help you create applications with data acquisition, dynamic signal acquisition, motion control, image acquisition, reconfigurable Optional 32 GB solid-state drive can replace the hard drive. Table 1. NI PXI-8101 RT Features 2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI Create Reliable Stand-Alone Systems To ensure reliable operation, embedded LabVIEW Real-Time applications continue to run even if the host PC is interrupted or rebooted. Because the PXI-8101 RT embedded controller runs in a separate chassis with a dedicated power supply, the operator can shut down the host computer entirely without disrupting the real-time program. For stand-alone operation, you can embed code in the system so that it starts automatically when the system boots, requiring no human interaction. Use the LabVIEW Professional Development System and LabVIEW Real-Time Module to compile your LabVIEW application into an executable and download it to your PXI-8101 RT controller. Ordering Information To order a complete PXI system based on a LabVIEW Real-Time embedded controller, visit ni.com/pxiadvisor. Controller Model NI PXI-8101 RT .............................................................................. 780955-33 Step 1. Select Memory Upgrade Standard 1 GB (1 x 1 GB DIMM) Recommended upgraded memory configurations 2 GB (1 x 2 GB DIMM must be purchased) 2 GB DDR2 RAM ........................................................................ 780446-2048 Step 2. Select Storage Options 250 GB standard temperature HDD ............................................... 779175-06 32 GB solid-state HDD ................................................................... 779175-08 Step 3. Select Accessories IEEE 1284 parallel port cable adapter (6 in.).................................. 777169-01 NI PXI-8252 IEEE 1394 interface module ....................................... 778925-01 Dual-Boot Option You can configure NI PXI embedded controllers to boot into Windows or the real-time OS. NI Measurement & Automation Explorer (MAX) includes features for installing and configuring PXI embedded controllers as LabVIEW Real-Time targets. The controllers use a hardware switch or BIOS setting to boot into the desired OS. The result is a PXI embedded controller that can run embedded LabVIEW Real-Time or Windows applications. When the controller is in real-time mode, you need another Windows computer to develop and debug the LabVIEW Real-Time code for the PXI controller. To enable a Windows PXI embedded controller to dual boot with the real-time OS, you must purchase the LabVIEW Real-Time embedded deployment software for the controller. DAQ I/O Mode Polling Interrupt Polling Interrupt Polling Interrupt Loop Rates (kHz) NI PXI-8101 RT 112 39 66 28 30 24 NI PXI-8104 RT 93 37 55 26 27 22 BUY NOW For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/pxi. Benchmark Processing Channels 1 1 Analog Input and Output PID 4 4 16 16 Table 1. Maximum loop rates for LabVIEW Real-Time PXI systems are shown. All benchmarks use the LabVIEW Real-Time Module Version 8.6.1 with NI-DAQmx Version 8.9. Benchmarks that do not test network performance run on a headless target without a direct Ethernet connection for maximum performance. Benchmarks that do test network performance use interrupt-mode Ethernet via a direct connection between the host PC and real-time target with a crossover cable. Visit ni.com or contact National Instruments for additional benchmarks. B UY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 2 2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI Specifications Specifications subject to change without notice. Environment Maximum altitude ................................. Pollution degree .................................... Indoor use only. 2,000 m (800 mbar) (at 25 °C ambient temperature) 2.0 GHz Intel Celeron 575 Mobile Intel GM45 Express Chipset 1066 MHz 1 GB DDR2 RAM PC2 6400 (standard) 2 GB DDR2 RAM PC2 6400 (maximum) 10/100/1000BASE-TX, RJ45 connector 80 GB minimum, internal 2.5 in., 9.5 mm Serial ATA 1.0 interface Integrated Graphics (Mobile Intel GM45 Express Chipset) 1 (RS232) IEEE 1284 Type C miniature connector (adapter cable not included) 2 Relative humidity range ........................ 2 Features Processor ............................................... Chipset .................................................. Front-side bus........................................ System memory (RAM) ......................... Ethernet ................................................. Hard drive .............................................. Video ..................................................... Serial ..................................................... Parallel .................................................. Hi-Speed USB........................................ Operating Environment Ambient temperature range1 ................ 5 to 50 °C2 (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) 10 to 90% noncondensing (tested in accordance with IEC-60068-2-56) For chassis that are not available in the online catalog at ni.com, contact National Instruments for supported operating temperatures. 2 5 to 40 °C for the NI PXI-1000B DC. 1 Storage Environment Ambient temperature range.................. -40 to 65 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range ........................ 5 to 95% noncondensing (tested in accordance with IEC-60068-2-56) Power Requirements Voltage (V) +3.3 +5 +12 -12 Current (A) Typical 2.25 3.50 0.001 0.00 Maximum 3.00 5.5 0.075 0.00 Shock and Vibration Operating shock .................................... 30 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27; test profile developed in accordance with MIL-PRF-28800F) Random vibration Operating .......................................... Nonoperating .................................... 5 to 500 Hz, 0.3 grms (with solid-state hard drive) 5 to 500 Hz, 2.4 grms (tested in accordance with IEC-60068-2-64; nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3) Physical Board dimensions.................................. 2-slot 3U PXI module 2 by 13 by 21.6 cm (1.59 by 5.1 by 8.5 in.) Slot requirements.................................. Compatibility ......................................... Weight................................................... One system slot plus one controller expansion slot Fully compatible with PXI Specification 0.983 kg (2.17 lb) typical B UY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 3 2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI Safety Compliance ◾◾ IEC 61010-1, EN 61010-1 ◾◾ UL 61010-01, CSA 61010-1 Electromagnetic Compatibility ◾◾ EN 61326 (IEC 61326): Class A emissions; Basic immunity ◾◾ EN 55011 (CISPR 11): Group 1, Class A emissions ◾◾ AS/NZS CISPR 11: Group 1, Class A emissions ◾◾ FCC 47 CFR Part 15B: Class A emissions ◾◾ ICES-001: Class A emissions CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: ◾◾ 2006/95/EC; Low-Voltage Directive (safety) ◾◾ 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. B UY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 4 NI Services and Support NI has the services and support to meet MA IN IN TA PL your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. AN SERVICE NEEDS LO Y V DE Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. EL OP Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. P DE Hardware Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive systemspecific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. Calibration Services NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com n 8 00 813 3693 n National Instruments info@ni.com ©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-11276-501-101-D
PXI-8101RT 价格&库存

很抱歉,暂时无法提供与“PXI-8101RT”相匹配的价格&库存,您可以联系我们找货

免费人工找货