Industrial Ethernet Switches – Managed and Unmanaged
NI UES-3880, NI MES-3980 NEW!
Industrial Features
• -40 to 70 °C operating temperature • Redundant dual 24 VDC power inputs • Class I, Div 2; ATEX Class 1, Zone 2 hazardous certifications • Metal enclosure, IP30 rated • DIN-rail or panel mount support • Relay output warning for power failure and port break alarm
Switching Features
• • • • Eight 10/100BASE-T(X) RJ45 connectors Broadcast storm protection IEEE 802.3/802.3u/802.3x support 10/100 M full-/half-duplex, MDI/MDI-X autosensing
Overview and Applications
The National Instruments unmanaged Ethernet switch (UES) and managed Ethernet switch (MES) provide the switching you need to connect all NI Ethernet-based devices to distributed systems and incorporate Ethernet-based devices and industrial protocols from third-party suppliers into NI applications.
Managed Ethernet Switch
The eight-port NI MES-3980 is a fully managed switch for networking NI Ethernet-based devices. The MES offers the same industrial specifications as the unmanaged switch as well as additional network management, network monitoring and security, network redundancy, and system alarm functionality. The MES-3980 provides Web-based configuration for easy management of these features and a Windows utility for configuration. MES-3980 features include: • Web-based and Windows configuration and management • Ring recovery time For complete specifications, see the NI MES-3980 User Manual
Power
UES-3880 Input voltage................................... 24 VDC (12 to 48 VDC), redundant inputs Input current ................................... 0.25 A @ 24 VDC Connection...................................... Removable 6-pin terminal block Overload current protection ........... 1.1 A Reverse polarity protection ............ Present MES-3980 Input voltage................................... 24 VDC (12 to 45 VDC), redundant dual inputs Input current ................................... 0.25 A @ 24 VDC Connection...................................... 2 removable 6-pin terminal blocks Overload current protection ........... Present, can withstand 1.6 A Reverse polarity protection ............ Present
at ni.com/manuals.
Technology
UES-3880 Standards........................................ Processing type............................... Flow control .................................... MES-3980 Standards........................................ IEEE 802.3, 802.3u, 802.3x Store and forward IEEE 802.3x back pressure
IEEE 802.3, 802.3u, 802.3x, 802.1D, 802.1w, 802.1Q, 802.1p, 802.1X, 802.3ad Protocols ......................................... IGMP v1/v2/v3 device, GVRP, SNMP v1/v2c/v3, DHCP Server/Client, DHCP Option 82, BOOTP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON MIB ................................................. MIB-II; Ethernet-Like; P-BRIDGE; Q-BRIDGE; Bridge; RSTP; RMON groups 1, 2, 3, and 9 Flow control .................................... IEEE 802.3x back pressure
Mechanical
UES-3880 Casing ............................................. IP30 protection, metal case Dimensions (w by h by d) ............... 53.6 by 135 by 105 mm (2.11 by 5.31 by 4.13 in.) Weight ............................................ 630 g Installation...................................... DIN-rail or panel mounting (optional kit) MES-3980 Casing ............................................. IP30 protection, aluminum case Dimensions (w by h by d) ............... 80.5 by 135 by 105 mm (3.17 by 5.31 by 4.13 in.) Weight ............................................ 1040 g Installation...................................... DIN-rail or panel mounting (optional kit)
Interface
UES-3880 RJ45 ports....................................... 10/100BASE-T(X) autonegotiation speed, F/H duplex mode, and auto MDI/MDI-X connection LED indicators................................. PWR1, PWR2, Fault, 10/100M (TP port), and 100M (fiber port) DIP switch....................................... Port break alarm mask Alarm contact ................................. One relay output with current carrying capacity of 1 A @ 24 VDC MES-3980 RJ45 ports....................................... 10/100BASE-T(X) autonegotiation speed, F/H duplex mode, and auto MDI/MDI-X connection LED indicators................................. PWR1, PWR2, Fault, Master, Coupler, 10/100M DIP switch....................................... Turbo Ring, Master, Coupler, Reserve Alarm contact ................................. Two relay outputs with current carrying capacity of 1 A @ 24 VDC Digital input ........................................ Two inputs with the same ground but electrically isolated from the electronics +13 to +30 V for state “1” -30 to +3 V for state “0” Maximum input current ...................... 8 mA
Environmental
UES-3880 Operating temperature ................... Storage temperature ...................... Ambient relative humidity .............. MES-3980 Operating temperature ................... -40 to 70 °C (-40 to 158 °F) -40 to 85 °C (-40 to 185 °F) 5 to 95% (noncondensing)
-40 to 70 °C (-40 to 158 °F) for T models Storage temperature ...................... -40 to 85 °C (-40 to 185 °F) Ambient relative humidity .............. 5 to 95% (noncondensing)
Regulatory Approvals
UES-3880 Safety.............................................. UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, TUV Hazardous location ......................... UL/cUL Class I, Division 2, Groups A, B, C, and D EMI.................................................. FCC Part 15, CISPR (EN55022) Class A
BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.)
4
Industrial Ethernet Switches – Managed and Unmanaged
EMS ................................................ EN61000-4-2 (ESD) Level 3, EN61000-4-3 (RS) Level 3, EN61000-4-4 (EFT) Level 3, EN61000-4-5 (Surge) Level 3, EN61000-4-6 (CS) Level 3 MES-3980 Safety.............................................. UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, TUV Hazardous location ......................... UL/cUL Class I, Division 2, Groups A, B, C, and D Maritime ......................................... DNV, GL EMI.................................................. FCC Part 15, CISPR (EN55022) Class A EMS ................................................ EN61000-4-2 (ESD), Level 3, EN61000-4-3 (RS), Level 3, EN61000-4-4 (EFT), Level 3, EN61000-4-5 (Surge), Level 3, EN61000-4-6 (CS), Level 3, EN61000-4-8, EN61000-4-11
BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.)
5
NI Services and Support
NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor.
Professional Services
Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration.
OEM Support
We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com • 800 813 3693
National Instruments • info@ni.com
*351533A-01*
351533A-01 2007-9140-161-101-D
© 2007 National Instruments Corporation. All rights reserved. CompactRIO, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.