0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
USB-6501

USB-6501

  • 厂商:

    NI

  • 封装:

  • 描述:

    USB-6501 - Small, portable digital I/O device/24 digital I/O lines, one 32-bit counter - National In...

  • 数据手册
  • 价格&库存
USB-6501 数据手册
Low-Cost Digital I/O Device for USB NI USB-6501 • Small, portable digital I/O device • 24 digital I/O lines, one 32-bit counter • Overvoltage protection, 8.5 mA current drive • Full-speed USB (12 Mb/s) bus interface • Built-in screw terminals with removable connectors for easier connectivity • OEM version available with 34-pin IDC mass termination connectivity Operating Systems • Windows Vista/XP/2000 • Mac OS X1 • Linux®1 Recommended Software • LabVIEW • LabWindows™/CVI Measurement Services Software (included) • NI-DAQmx driver software • Measurement & Automation Explorer configuration utility 1Mac OS X and Linux users need to download NI-DAQmx Base. Overview The National Instruments USB-6501 is a portable digital I/O device, providing reliable data acquisition and control at a low price. With plug-and-play USB connectivity, the NI USB-6501 is simple enough for home/academic applications but robust and versatile enough for laboratory/industrial applications. The board-only version is ideal for embedded OEM applications. Digital I/O Lines 24 Counter/ Timers 1 Current Drive 8.5 mA Industrial Logic Level Feature Set 5 V TTL / CMOS – GND +5V P1.7 P1.6 P1.5 P1.4 GND GND P2.7 P2.6 P2.5 P2.4 P2.3 P2.2 P2.1 P2.0 Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Signal GND +5 V P1.7 P1.6 P1.5 P1.4 GND GND P2.7 P2.6 P2.5 P2.4 P2.3 P2.2 P2.1 P2.0 Product NI 6501 Bus USB Table 1. USB-6501 Features Hardware The USB-6501 is a full-speed USB device that provides 24 DIO lines and a 32-bit counter. The 24 digital lines are arranged in three ports: P0., P1., and P2.. P2.7 can also function as a 32-bit counter. You can individually program each of the USB-6501 DIO lines as a DI or DO line and use the DIO lines to monitor or control digital signals. All samples of the DI lines and updates of the DO lines are software-timed. The default configuration of the USB-6501 DIO ports is open-drain, for 5 V operation with an onboard 4.7 kΩ pull-up resistor. You can add an external, user-provided, pull-up resistor to increase the source current drive up to 8.5 mA per line. Each DIO signal is protected against overvoltage, undervoltage, and overcurrent conditions, as well as ESD events. At system startup and reset, the hardware sets all DIO lines to high-impedance inputs. GND +5V P1.3 P1.2 P1.1 P1.0 GND GND P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0 Terminal 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Signal P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 GND GND P1.0 P1.1 P1.2 P1.3 +5 V GND Figure 1. USB-6501 Pinout Low-Cost Digital I/O Device for USB The data acquisition device does not drive the signal high or low. Each line has a weak pull-up resistor connected to it. You can configure P2.7 as the source for a 32-bit counter. In this mode, the device counts high to low transitions (falling edges) on P2.7. You can arm and disarm the counter and read or reset the count through software. The USB-6501 supplies a nominal 5 V from two pins, one on each screw-terminal block. You can use the voltage source, which is provided by the USB host, to power external components. The USB-6501 features current limiting short circuit protection for safe USB host power use. +5 V 1 LED LED 2 3 +5 V 4 Switch I/O Connector GND TTL Signal P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 Figure 3. Interactive Control Panel Example Program Shipped with the USB-6501 Recommended Accessories The USB-6501 has built-in screw terminals for connectivity; no additional accessories are required. Board-Only Version for OEMs A board-only version of the USB-6501 is available to OEMs for use in embedded applications. The OEM version offers a 34-pin IDC ribbon cable header for mass termination instead of screw-terminal connectivity. You can mount the OEM version using standoffs (not included in kit) with your own enclosure. For information on special configurations and pricing, visit ni.com/oem. 1. P0.0 configured as an open-drain digital output driving an LED 2. P0.2 configured as a push-pull digital output driving an LED 3. P0.4 configured as a digital input receiving a TTL signal from a gated inverter 4. P0.7 configured as a digital input receiving a 0 V or 5 V signal from a switch Figure 2. Example of Connecting a Load Ordering Information Software The USB-6501 is shipped with NI-DAQmx measurement services software, a high-performance multithreaded driver for interactive configuration and data acquisition. Use it to develop customized data acquisition applications with NI LabVIEW or C-based development environments. Examples include an interactive control panel to help you get started with your application quickly. NI USB-6501 ..........................................................................779205-01 Includes NI-DAQmx Base software and a USB cable. NI USB-6501 hardware only (for OEM) ................................192317-50 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/daq. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 2 Low-Cost Digital I/O Device for USB Specifications The following specifications are typical at 25 °C, unless otherwise noted. Digital I/O Number of lines P0............................................... P1............................................... P2............................................... Direction control ................................. Output driver type ............................... Pull-up resistor.................................... Absolute voltage range....................... Power-on state.................................... Digital logic levels 8 8 8 Input or output, software-selectable Push-pull or open-drain, software-selectable 4.7 kΩ -0.5 to 5.8 V with respect to GND Input (high impedance) Min -0.3 2.0 – – – 2.8 2.0 2.0 2.0 Max 0.8 5.8 50 0.4 0.8 3.6 3.5 5.0 – Units V V µA V V V V V V With connectors ............................. 8.18 by 8.51 by 2.31 cm (3.22 by 3.35 by 0.91 in.) I/O connectors..................................... USB series B receptacle, (2) 16 position (screw-terminal) plug headers Screw-terminal wiring ........................ 16 to 28 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end Torque for screw terminals................. 0.22 to 0.25 N · m (2.0 to 2.2 lb · in.) Weight................................................. 84 g (3 oz) Safety Standards The USB-6501 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1 • CSA 61010-1 Note: For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Level Input low voltage Input high voltage Input leakage current Output low voltage (I = 2 mA) Output low voltage (I = 8.5 mA) Output high voltage Push-pull, I = -2 mA Push-pull, I = -8.5 mA Open-drain, I = -0.4 mA, nominal Open-drain, I = -7.5 mA, with external pull-up resistor Overvoltage Protection Connect only voltages that are within these limits. Channel-to-COM (one channel) .......... ±30 V max, Measurement Category I Channel-to-COM (one port, all channels) ....................... ±8.9 V max, Measurement Category I Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution: Do not use this module for connection to signals or for measurements within Measurement Categories II, III, or IV. Counter Number of counters ............................ 1 (P2.7 can be configured as the counter) Resolution ........................................... 32 bits Counter measurements....................... Falling edge counting Maximum input frequency.................. 5 MHz Minimum high pulse width................. 100 ns Minimum low pulse width.................. 100 ns Bus Interface USB specification................................ USB full-speed (12 Mb/s) External Voltage +5 V output Voltage............................................ 4.00 V min, 5.25 V max Current ............................................ 230 mA max Hazardous Locations The USB-6501 is not certified for use in hazardous locations. Environmental The USB-6501 device is intended for indoor use only. Operating temperature (IEC 60068-2-1 and IEC 60068-2-2)..... 0 to 55 °C Operating humidity (IEC 60068-2-56) ............................. 10 to 90% RH, noncondensing Maximum altitude............................... 2,000 m (at 25 °C ambient temperature) Storage temperature (IEC 60068-2-1 and IEC 60068-2-2)... -40 to 85 °C Storage relative humidity (IEC 60068-2-56) ............................. 5 to 90%, noncondensing Pollution degree (IEC 60664) .............. 2 Power Requirements USB 4.5 to 5.25 VDC............................... 80 mA typical, 500 mA max USB Suspend .................................. 500 µA max, all DIO lines disconnected Physical Characteristics Dimensions Without connectors ........................ 6.35 by 8.51 by 2.31 cm (2.50 by 3.35 by 0.91 in.) BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 3 Low-Cost Digital I/O Device for USB Electromagnetic Compatibility Emissions ............................................ EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity.............................................. Industrial levels per EN 61326:1997 + A2:2001, Table 1 EMC/EMI............................................. CE, C-Tick, and FCC Part 15 (Class A) Compliant Note: For EMC compliance, operate this device with shielded cabling. You must insulate signal connections for the maximum voltage for which the device is rated. Do not exceed the maximum ratings for the device. Do not install wiring while the device is live with electrical signals. Do not remove or add connector blocks when power is connected to the system. Avoid contact between your body and the connector block signal when hot swapping modules. Remove power from signal lines before connecting them to or disconnecting them from the device. Operate the device at or below Measurement Category I1. Measurement circuits are subjected to working voltages2 and transient stresses (overvoltage) from the circuit to which they are connected during measurement or test. Measurement categories establish standard impulse withstand voltage levels that commonly occur in electrical distribution systems. The following is a description of measurement categories: • Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS3 voltage. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limitedenergy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. 1 Measurement Category as defined in electrical safety standard IEC 61010-1. Measurement Category is also referred to as Installation Category. 2 Working Voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation. 3 MAINS is defined as a hazardous live electrical supply system that powers equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring purposes. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety) ........... 73/23/EEC Electromagnetic Compatibility Directive (EMC)............................... 89/336/EEC Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Safety Guidelines Caution: Operate the hardware only as described in these operating instructions. The following section contains important safety information that you must follow when installing and using the USB-6501. Do not operate the USB-6501 in a manner not specified in this document. Misuse of the device can result in a hazard. You can compromise the safety protection built into the device if the device is damaged in any way. If the device is damaged, contact National Instruments for repair. Do not substitute parts or modify the device except as described in this document. Use the device only with the chassis, modules, accessories, and cables specified in the installation instructions. You must have all covers and filler panels installed during operation of the device. Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. If you must operate the device in such an environment, it must be in a suitably rated enclosure. If you need to clean the device, use a dry cloth. Make sure that the device is completely dry and free from contaminants before returning it to service. Operate the device only at or below Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resistivity. The following is a description of pollution degrees: • Pollution Degree 1 means no pollution or only dry, nonconductive pollution occurs. The pollution has no influence. • Pollution Degree 2 means that only nonconductive pollution occurs in most cases. Occasionally, however, a temporary conductivity caused by condensation must be expected. • Pollution Degree 3 means that conductive pollution occurs, or dry, nonconductive pollution occurs that becomes conductive due to condensation. • Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet (for example, 115 V for U.S. or 230 V for Europe). Examples of Measurement Category II are measurements performed on household appliances, portable tools, and similar E Series devices. • Measurement Category III is for measurements performed in the building installation at the distribution level. This category refers to measurements on hard-wired equipment such as equipment in fixed installations, distribution boards, and circuit breakers. Other examples are wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and stationary motors with permanent connections to fixed installations. • Measurement Category IV is for measurements performed at the primary electrical supply installation (
USB-6501 价格&库存

很抱歉,暂时无法提供与“USB-6501”相匹配的价格&库存,您可以联系我们找货

免费人工找货