LM140JAN Three Terminal Positive Regulators February 2006 LM140JAN Three Terminal Positive Regulators General Description The monolithic 3-terminal positive voltage regulators employ internal current-limiting, thermal shutdown and safe-area compensation, making them essentially indestructible. If adequate heat sinking is provided, they can deliver over 0.5A and 1.0A output current. They are intended as fixed voltage regulators in a wide range of applications including local (on-card) regulation for elimination of noise and distribution problems associated with single-point regulation. In addition to use as fixed voltage regulators, these devices can be used with external components to obtain adjustable output voltages and currents. Considerable effort was expended to make the entire series of regulators easy to use and minimize the number of external components. It is not necessary to bypass the output, although this does improve transient response. Input bypassing is needed only if the regulator is located far from the filter capacitor of the power supply. Features n n n n n Complete specifications at 0.5A and 1.0A loads No external components Internal thermal overload protection Internal short circuit current-limiting Output transistor safe-area compensation Ordering Information NS Part Number JL140-5BXA JL140-5BYA JL140-5SXA JL140-5SYA JL140-12BXA JL140-12BYA JL140-12SXA JL140-15BXA JL140-15BYA JL140-15SYA SMD Part Number JM38510/10702BXA JM38510/10706BYA JM38510/10702SXA JM38510/10706SYA JM38510/10703BXA JM38510/10707BYA JM38510/10703SXA JM38510/10704BXA JM38510/10708BYA JM38510/10708SYA NS Package Number H03A K02C H03A K02C H03A K02C H03A H03A K02C K02C Package Description 3LD TO-39 Metal Can 2LD TO-3 Metal Can 3LD TO-39 Metal Can 2LD TO-3 Metal Can 3LD TO-39 Metal Can 2LD TO-3 Metal Can 3LD TO-39 Metal Can 3LD TO-39 Metal Can 2LD TO-3 Metal Can 2LD TO-3 Metal Can Connection Diagrams Steel Metal Can TO-39 Package (H) TO-3 Metal Can (K) 20164602 20164601 Bottom View See NS Package Number H03A Bottom View See NS Package Number K02C © 2006 National Semiconductor Corporation DS201646 www.national.com LM140JAN Absolute Maximum Ratings (Note 1) DC Input Voltage Internal Power Dissipation (Note 2) Maximum Junction Temperature (TJmax) Storage Temperature Range Operating Temperature Range Lead Temperature (Soldering 10 seconds) Thermal Resistance θJA T0−5 (Still Air) T0−5 (500 LF/Min Air Flow) T0−3 (Still Air) T0−3 (500 LF/Min Air Flow) θJC T0−5 T0−3 ESD Susceptibility (Note 3) 15˚C/W 4˚C/W 2KV 232˚C/W 77˚C/W 35˚C/W TBD 35V Internally Limited 150˚C -65˚C ≤ TA ≤ +150˚C -55˚C ≤ TA ≤ +125˚C 300˚C Quality Conformance Inspection MIL-Std-883, Method 5005 - Group A Subgroup 1 2 3 4 5 6 7 8A 8B 9 10 11 12 13 14 Description Static tests at Static tests at Static tests at Dynamic tests at Dynamic tests at Dynamic tests at Functional tests at Functional tests at Functional tests at Switching tests at Switching tests at Switching tests at Settling time at Settling time at Settling time at Temp ˚C 25 125 -55 25 125 -55 25 125 -55 25 125 -55 25 125 -55 www.national.com 2 LM140JAN LM140H-5.0 (JL140-5BXA, SXA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 8V, IL = -5mA VI = 8V, IL = -500mA VI = 20V, IL = -5mA VI = 20V, IL = -500mA VI = 35V, IL = -5mA VI = 35V, IL = -50mA VRLine VRLoad ISCD ∆ISCD Line IOL IOS Line Regulation Load Regulation Stand by Current Drain Stand by IDrain vs. VLine Overload Current Output Short Circuit Current 8V ≤ VI ≤ 35V, IL = -50mA 8V ≤ VI ≤ 25V, IL = -350mA VI = 10V, -500mA ≤ IL ≤ -5mA VI = 35V, -50mA ≤ IL ≤ -5mA VI = 10V, IL = -5mA VI = 35V, IL = -5mA 8V ≤ VI ≤ 35V, IL = -5mA VI = 10V, -500mA ≤ IL ≤ -5mA VI = 8V, Forced ∆VO = -0.48V VI = 10V VI = 25V VI = 35V VO (2) VO (3) ∆VO / ∆T Output Voltage Output Voltage Average Temperature Coefficient of Output Voltage VI = 10V, IL = -5mA VI = 10V, IL = -5mA VI = 10V, IL = -5mA, 25˚C ≤ TA ≤ 125˚C VI = 10V, IL = -5mA, -55˚C ≤ TA ≤ 25˚C (Note 4) (Note 5) (Note 6) (Note 6) ∆ISCD Load Stand by IDrain vs. ILoad Notes Min 4.75 4.75 4.75 4.75 4.75 4.75 -150 -50 -100 -150 -7.0 -8.0 -1.0 -0.5 -2.0 -2.0 -1.5 -1.0 4.7 4.75 -2.0 -2.0 Max 5.25 5.25 5.25 5.25 5.25 5.25 150 50 100 150 -0.5 -0.5 1.0 0.5 -0.5 -0.01 -0.01 -0.01 5.3 5.25 2.0 2.0 Unit V V V V V V mV mV mV mV mA mA mA mA A A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B AC Parameters Symbol NO ∆VO / ∆VI ∆VO / ∆IL ∆VI / ∆VO Parameter Output Noise Voltage Transient Line Response Transient Load Response Ripple Rejection Conditions VI = 10V, IL = -50mA VI = 10V, IL = -5mA, VPulse = 3V VI = 10V, ∆IL = -200mA, IL = -50mA VI = 10V, IL = -125mA, eI = 1VRMS at ƒ = 2400Hz, 60 Notes Min Max 125 30 2.5 Unit µVRMS mV/V mV/mA dB Subgroups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 8V, IL = -5mA VI = 8V, IL = -500mA VI = 20V, IL = -5mA VI = 20V, IL = -500mA VI = 35V, IL = -5mA VI = 35V, IL = -50mA ISCD Stand by Current Drain VI = 10V, IL = -5mA 3 Notes Min Max Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 www.national.com -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -20 20 LM140JAN LM140H-12 (JL140-12BXA, SXA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 15V, IL = -5mA VI = 15V, IL = -0.5A VI = 27V, IL = -5mA VI = 27V, IL = -0.5A VI = 35V, IL = -5mA VI = 35V, IL = -50mA VRLine VRLoad ISCD ∆ISCD Line IOL IOS Line Regulation Load Regulation Stand by Current Drain Stand by IDrain vs. VLine Over Load Current Output Short Circuit Current 15V ≤ VI ≤ 35V, IL = -50mA 15V ≤ VI ≤ 32V, IL = -350mA VI = 17V, -500mA ≤ IL ≤ -5mA VI = 35V, -50mA ≤ IL ≤ -5mA VI = 17V, IL = -5mA VI = 35V, IL = -5mA 15V ≤ VI ≤ 35V, IL = -5mA VI = 17V, -500mA ≤ IL ≤ -5mA VI = 15V, ∆VO = -1.13V VI = 17V VI = 32V VI = 35V VO (2) VO (3) ∆VO / ∆T Output Voltage Output Voltage Average Temperature Coefficient Output Voltage VI = 17V, IL = -5mA VI = 17V, IL = -5mA 25˚C ≤ TA ≤ +125˚C, VI = 17V, IL = -5mA -55˚C ≤ TA ≤ 25˚C, VI = 17V, IL = -5mA (Note 4) (Note 5) (Note 7) (Note 7) ∆ISCD Load Stand by IDrain vs. ILoad Notes Min 11.4 11.4 11.4 11.4 11.4 11.4 -360 -120 -240 -360 -7.0 -8.0 -1.0 -0.5 -2.0 Max 12.6 12.6 12.6 12.6 12.6 12.6 360 120 240 360 -0.5 -0.5 1.0 0.5 -0.5 Unit V V V V V V mV mV mV mV mA mA mA mA A A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B -1.75 -0.01 -1.25 -0.01 -1.00 -0.01 11.28 12.72 11.4 -3.0 -3.0 12.6 3.0 3.0 AC Parameters Symbol NO ∆VO / ∆IL ∆VO / ∆VI ∆VI / ∆VO Parameter Output Noise Voltage Transient Load Response Transient Line Response Ripple Rejection Conditions VI = 17V, IL = -50mA VI = 17V, IL = -50mA, ∆IL = -200mA VI = 17V, VPulse = 3V, IL = -5mA VI = 17V, IL = -125mA, eI = 1VRMS at ƒ = 2400Hz 55 Notes Min Max 250 2.5 30 Unit µVRMS mV/mA mV/V dB Subgroups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 15V, IL = -5mA VI = 15V, IL = -0.5A VI = 27V, IL = -5mA VI = 27V, IL = -0.5A VI = 35V, IL = -5mA VI = 35V, IL = -50mA ISCD Stand by Current Drain VI = 17V, IL = -5mA 4 Notes Min -0.06 -0.06 -0.06 -0.06 -0.06 -0.06 -20 Max 0.06 0.06 0.06 0.06 0.06 0.06 20 Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 www.national.com LM140JAN LM140H-15 (JL140-15BXA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 18.5V, IL = -5mA VI = 18.5V, IL = -500mA VI = 30V, IL = -5mA VI = 30V, IL = -500mA VI = 35V, IL = -5mA VI = 35V, IL = -50mA VRLine VRLOAD ISCD ∆ISCD Line IOL IOS VO (2) VO (3) ∆VO / ∆T Line Regulation Load Regulation Stand by Current Drain Stand by IDrain vs. VLine Overload Current Output Short Circuit Current Output Short Circuit Current Output Voltage Output Voltage Average Temperature Coefficient Output Voltage Average Temperature Coefficient Output Voltage 18.5V ≤ VI ≤ 35V, IL = -350mA -500mA ≤ IL ≤ -5mA, VI = 20V -50mA ≤ IL ≤ -5mA, VI = 35V VI = 20V, IL = -5mA VI = 35V, IL = -5mA 18.5V ≤ VI ≤ 35V, IL = -5mA -500mA ≤ IL ≤ -5mA, VI = 20V Forced ∆VO = -1.43V, VI = 18.5V VI = 20V VI = 35V VI = 20V, IL = -5mA VI = 20V, IL = -5mA 25˚C ≤ TA ≤ +125˚C, VI = 20V, IL = -5mA -55˚C ≤ TA ≤ 25˚C, VI = 20V, IL = -5mA (Note 4) (Note 5) (Note 7) (Note 7) ∆ISCD Load Stand by IDrain vs. ILoad Notes Min Max Unit V V V V V V mV mV mV mA mA mA mA A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 -150 -300 -450 -7.0 -8.0 -1.0 -0.5 -2.0 150 300 450 -0.5 -0.5 1.0 0.5 -0.5 -1.75 -0.01 -1.0 14.1 -3.75 -3.75 -0.01 15.9 3.75 3.75 14.25 15.75 AC Parameters Symbol NO ∆VO / ∆IL ∆VO / ∆VI ∆VI / ∆VO Parameter Output Noise Voltage Transient Load Response Transient Line Response Ripple Rejection Conditions VI = 20V, IL = -50mA ∆IL = -200mA, VI = 20V, IL = -50mA VI = 20V, IL = -5mA, VPulse = 3V VI = 20V, IL = -125mA, eI = 1VRMS at ƒ = 2400Hz 53 Notes Min Max 300 2.5 30 Unit µVRMS mV/mA mV/V dB Subgroups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 18.5V, IL = -5mA VI = 18.5V, IL = -500mA VI = 30V, IL = -5mA VI = 30V, IL = -500mA VI = 35V, IL = -5mA VI = 35V, IL = -50mA ISCD Stand by Current Drain VI = 20V, IL = -5mA Notes Min Max Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -20 20 5 www.national.com LM140JAN LM140K-5.0 (JL140-5BYA, SYA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 8V, IL = -5mA VI = 8V, IL = -1A VI = 20V, IL = -5mA VI = 20V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A VRLine VRLoad ISCD ∆ISCD Line IOL IOS Line Regulation Load Regulation Stand by Current Drain Stand by IDrain vs. VLine Overload Current Output Short Circuit Current 8V ≤ VI ≤ 35V, IL = -0.1A 8V ≤ VI ≤ 25V, IL = -0.5A VI = 10V, -1A ≤ IL ≤ -5mA VI = 35V, -0.1A ≤ IL ≤ -5mA VI = 10V, IL = -5mA VI = 35V, IL = -5mA 8V ≤ VI ≤ 35V, IL = -5mA VI = 10V, -1A ≤ IL ≤ -5mA VI = 8V, Forced ∆VO = -0.48V VI = 10V VI = 25V VI = 35V VO (2) VO (3) ∆VO / ∆T Output Voltage Output Voltage Average Temperature Coefficient Output Voltage VI = 10V, IL = -5mA VI = 10V, IL = -5mA VI = 10V, IL = -5mA, 25˚C ≤ TA ≤ 125˚C VI = 10V, IL = -5mA, -55˚C ≤ TA ≤ 25˚C (Note 4) (Note 5) (Note 6) (Note 6) ∆ISCD Load Stand by IDrain vs. ILoad Notes Min 4.75 4.75 4.75 4.75 4.75 4.75 -150 -50 -100 -150 -7.0 -8.0 -1.0 -0.5 -4.0 -4.0 -3.0 -2.0 4.7 4.75 -2.0 -2.0 Max 5.25 5.25 5.25 5.25 5.25 5.25 150 50 100 150 -0.5 -0.5 1.0 0.5 -1.0 -0.02 -0.02 -0.02 5.3 5.25 2.0 2.0 Unit V V V V V V mV mV mV mV mA mA mA mA A A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B AC Parameters Symbol NO ∆VO /∆ VI ∆VO /∆ IL ∆VI /∆ VO Parameter Output Noise Voltage Transient Line Response Transient Load Response Ripple Rejection Conditions VI = 10V, IL = -0.1A VI = 10V, VPulse = 3V, IL = -5mA VI = 10V, ∆IL = -400mA, IL = -100mA VI = 10V, IL = -350mA, eI = 1VRMS at ƒ = 2400Hz 60 Notes Min Max 125 30 2.5 Unit µVRMS mV/V mV/mA dB Subgroups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 8V, IL = -5mA VI = 8V, IL = -1A VI = 20V, IL = -5mA VI = 20V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A ISCD Stand by Current Drain VI = 10V, IL = -5mA 6 Notes Min Max Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -0.025 0.025 -20 20 www.national.com LM140JAN LM140K-12 (JL140-12BYA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 15V, IL = -5mA VI = 15V, IL = -1A VI = 27V, IL = -5mA VI = 27V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A VRLine VRLoad ISCD Line Regulation Load Regulation Stand by Current Drain 15V ≤ VI ≤ 35V, IL = -0.1A 15V ≤ VI ≤ 32V, IL = -0.5A VI = 17V, -1A ≤ IL ≤ -5mA VI = 35V, -0.1A ≤ IL ≤ -5mA VI = 17V, IL = -5mA VI = 35V, IL = -5mA ∆ISCD Line Stand by IDrain vs. VLine ∆ISCD Load Stand by IDrain vs. ILoad IOL IOS Over Load Current Output Short Circuit Current 15V ≤ VI ≤ 35V, IL = -5mA VI = 17V, -1A ≤ IL ≤ -5mA Forced ∆VO = -1.13V, VI = 15V VI = 17V VI = 32V VI = 35V VO (2) VO (3) ∆VO / ∆T Output Voltage Output Voltage Average Temperature Coefficient Output Voltage VI = 17V, IL = -5mA VI = 17V, IL = -5mA 25˚C ≤ TA ≤ +125˚C, VI = 17V, IL = -5mA -55˚C ≤ TA ≤ 25˚C, VI = 17V, IL = -5mA (Note 4) (Note 5) (Note 7) (Note 7) Notes Min 11.4 11.4 11.4 11.4 11.4 11.4 -360 -120 -240 -360 -7.0 -8.0 -1.0 -0.5 -4.0 -3.5 -2.5 -2.0 11.4 -3.0 -3.0 Max 12.6 12.6 12.6 12.6 12.6 12.6 360 120 240 360 -0.5 -0.5 1.0 0.5 -1.0 -0.02 -0.02 -0.02 12.6 3.0 3.0 Unit V V V V V V mV mV mV mV mA mA mA mA A A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B 11.28 12.72 AC Parameters Symbol NO ∆VO / ∆IL ∆VO / ∆VI ∆VI / ∆VO Parameter Output Noise Voltage Transient Load Response Transient Line Response Ripple Rejection Conditions VI = 17V, IL = -0.1A VI = 17V, IL = -100mA, ∆IL = -400mA VI = 17V, VPulse = 3V, IL = -5mA VI = 17V, eI = 1VRMS at ƒ = 2400Hz, IL = -350mA 55 Notes Min Max 250 2.5 30 Unit µVRMS mV/mA mV/V dB Sup groups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 15V, IL = -5mA VI = 15V, IL = -1A VI = 27V, IL = -5mA VI = 27V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A ISCD Stand by Current Drain VI = 17V, IL = -5mA 7 Notes Min -0.06 -0.06 -0.06 -0.06 -0.06 -0.06 -20 Max 0.06 0.06 0.06 0.06 0.06 0.06 20 Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 www.national.com LM140JAN LM140K-15 (JL140-15BYA, SYA) JAN Electrical Characteristics DC Parameters Symbol VO (1) Parameter Output Voltage Conditions VI = 18.5V, IL = -5mA VI = 18.5V, IL = -1A VI = 30V, IL = -5mA VI = 30V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A VRLine VRLoad ISCD ∆ISCD Line IOL IOS VO (2) VO (3) ∆VO / ∆T Line Regulation Load Regulation Stand by Current Drain Stand by IDrain vs. VLine Overload Current Output Short Circuit Current Output Voltage Output Voltage Average Temperature Coefficient Output Voltage 18.5V ≤ VI ≤ 35V, IL = -0.5A VI = 20V, -1A ≤ IL ≤ -5mA VI = 35V, -0.1A ≤ IL ≤ -5mA VI = 20V, IL = -5mA VI = 35V, IL = -5mA 18.5V ≤ VI ≤ 35V, IL = -5mA VI = 20V, -1A ≤ IL ≤ -5mA Forced ∆VO = -1.43V, VI = 18.5V VI = 20V VI = 35V VI = 20V, IL = -5mA VI = 20V, IL = -5mA 25˚C ≤ TA ≤ +125˚C, VI = 20V, IL = -5mA -55˚C ≤ TA ≤ 25˚C, VI = 20V, IL = -5mA (Note 4) (Note 5) (Note 8) (Note 8) ∆ISCD Load Stand by IDrain vs. ILoad Notes Min Max Unit V V V V V V mV mV mV mA mA mA mA A A A V V mV/˚C mV/˚C Subgroups 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 2 7, 8A, 8B 8A 8B 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 14.25 15.75 -150 -300 -450 -7.0 -8.0 -1.0 -0.5 -4.0 -3.5 -2.0 14.1 -3.75 -3.75 150 300 450 -0.5 -0.5 1.0 0.5 -1.0 -0.02 -0.02 15.9 3.75 3.75 14.25 15.75 AC Parameters Symbol NO ∆VO / ∆IL ∆VO / ∆VI ∆VI / ∆VO Parameter Output Noise Voltage Transient Load Response Transient Line Response Ripple Rejection Conditions VI = 20V, IL = -0.1A ∆IL = -400mA, VI = 20V, IL = -100mA VI = 20V, VPulse = 3V, IL = -5mA VI = 20V, IL = -350mA, eI = 1VRMS at f = 2400Hz 53 Notes Min Max 300 2.5 30 Unit µVRMS mV/mA mV/V dB Subgroups 7 7 7 4 DC Drift Parameters Delta calculations performed on JAN S devices at group B, Subgroup 5, only. Symbol VO Parameter Output Voltage Conditions VI = 18.5V, IL = -5mA VI = 18.5V, IL = -1A VI = 30V, IL = -5mA VI = 30V, IL = -1A VI = 35V, IL = -5mA VI = 35V, IL = -0.1A ISCD Stand by Current Drain VI = 20V, IL = -5mA Notes Min Max Unit V V V V V V % Subgroups 1 1 1 1 1 1 1 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -0.075 0.075 -20 20 www.national.com 8 LM140JAN Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature), θJA (package junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/θJA or the number given in the Absolute Maximum Ratings, whichever is lower. Note 3: Human body model, 100pF discharged through 1.5KΩ Note 4: Tested at TA = +125˚C, correlated to TA = +150˚C. Note 5: Tested at extremes as a set up for ∆VO/∆T tests. Note 6: Calculated parameter. For calculations use VO @ VI = 10V, IL = −5mA.(Note 5) Note 7: Calculated parameter. For calculations use VO @ VI = 17V, IL = −5mA.(Note 5) Note 8: Calculated parameter. For calculations use VO @ VI = 20V, IL = −5mA.(Note 5) 9 www.national.com LM140JAN Revision History Released 02/07/06 Revision A Section New Release, Corporate format Originator L. Lytle Changes 6 MDS data sheets converted into one Corp. data sheet format. The drift tables were eliminated from the 883 section since it did not apply. MDS data sheets MJLM140-05-H Rev 0B0, MJLM140-05-K Rev. 0B0, MJLM140-12-H Rev 0B0, MJLM140-12-K Rev 0B0, MJLM140-15-H Rev 0B0, and MJLM140-15-K Rev 0B0 will be archived. www.national.com 10 LM140JAN Physical Dimensions inches (millimeters) unless otherwise noted Metal Can TO-39 (H) NS Package Number H03A Steel Metal Can Package (K) NS Package Number K02C 11 www.national.com LM140JAN Three Terminal Positive Regulators Notes National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. For the most current product information visit us at www.national.com. LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. BANNED SUBSTANCE COMPLIANCE National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2. Leadfree products are RoHS compliant. National Semiconductor Americas Customer Support Center Email: new.feedback@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Customer Support Center Fax: +49 (0) 180-530 85 86 Email: europe.support@nsc.com Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 National Semiconductor Asia Pacific Customer Support Center Email: ap.support@nsc.com National Semiconductor Japan Customer Support Center Fax: 81-3-5639-7507 Email: jpn.feedback@nsc.com Tel: 81-3-5639-7560 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
LM140JAN
### 物料型号 - NS Part Number:JL140-5BXA、JL140-5BYA、JL140-5SXA、JL140-5SYA、JL140-12BXA、JL140-12BYA、JL140-12SXA、JL140-15BXA、JL140-15BYA、JL140-15SYA

### 器件简介 LM140JAN是一种集成的三端子正电压调节器,具有内部电流限制、热关闭和安全区域补偿功能,使其几乎不可摧毁。如果提供足够的散热,它们可以提供超过0.5A和1.0A的输出电流。它们被设计为固定电压调节器,用于广泛的应用,包括局部(现场)调节,以消除与单点调节相关的噪声和分配问题。除了作为固定电压调节器使用外,这些设备还可以与外部组件一起使用,以获得可调输出电压和电流。

### 引脚分配 - TO-39金属罐(H):3LD TO-39金属罐 - TO-3金属罐(K):2LD TO-3金属罐

### 参数特性 - 绝对最大额定值:DC输入电压35V,内部功率耗散内部限制,最大结温150°C。 - 电气特性:包括输出电压、线路调节、负载调节、待机电流消耗等参数。

### 功能详解 LM140JAN三端子正电压调节器易于使用,并最小化外部组件数量。不需要旁路输出,尽管这可以改善瞬态响应。只有当调节器远离电源滤波电容器时,才需要输入旁路。

### 应用信息 适用于需要固定电压调节的广泛应用,包括现场调节以消除噪声和分配问题。也可以与外部组件配合使用,以获得可调输出电压和电流。

### 封装信息 - SMD Part Number:JM38510/10702BXA、JM38510/10706BYA、JM38510/10702SXA等 - NS Package Number:H03A(3LD TO-39金属罐)、K02C(2LD TO-3金属罐)