LM5025SD

LM5025SD

  • 厂商:

    NSC

  • 封装:

  • 描述:

    LM5025SD - Active Clamp Voltage Mode PWM Controller - National Semiconductor

  • 数据手册
  • 价格&库存
LM5025SD 数据手册
LM5025 Active Clamp Voltage Mode PWM Controller March 2004 LM5025 Active Clamp Voltage Mode PWM Controller General Description The LM5025 PWM controller contains all of the features necessary to implement power converters utilizing the Active Clamp / Reset technique. The device can be configured to control either a P-Channel clamp switch or an N-Channel clamp switch. With the active clamp technique, higher efficiencies and greater power densities can be realized compared to conventional catch winding or RDC clamp / reset techniques. Two control outputs are provided, the main power switch control (OUT_A) and the active clamp switch control (OUT_B). The active clamp output can be configured for either a guaranteed overlap time (for P-Channel switch applications) or a guaranteed deadtime (for N_Channel applications). The two internal compound gate drivers parallel both MOS and Bipolar devices, providing superior gate drive characteristics. This controller is designed for high-speed operation including an oscillator frequency range up to 1MHz and total PWM and current sense propagation delays less than 100ns. The LM5025 includes a high-voltage start-up regulator that operates over a wide input range of 13V to 90V. Additional features include: Line Under Voltage Lockout (UVLO), softstart, oscillator UP/DOWN sync capability, precision reference and thermal shutdown. Features n Internal Start-up Bias Regulator n 3A Compound Main Gate Driver n Programmable Line Under-Voltage Lockout (UVLO) with Adjustable Hysteresis n Voltage Mode Control with Feed-Forward n Adjustable Dual Mode Over-Current Protection n Programmable Overlap or Deadtime between the Main and Active Clamp Outputs n Volt x Second Clamp n Programmable Soft-start n Leading Edge Blanking n Single Resistor Programmable Oscillator n Oscillator UP / DOWN Sync Capability n Precision 5V Reference n Thermal Shutdown Packages n TSSOP-16 n LLP-16 (5x5 mm) Thermally Enhanced Typical Application Circuit 20086901 Simplified Active Clamp Forward Power Converter © 2004 National Semiconductor Corporation DS200869 www.national.com LM5025 Connection Diagram 20086916 16-Lead TSSOP, LLP Ordering Information Order Number LM5025MTC LM5025MTCX LM5025SD LM5025SDX Package Type TSSOP-16 TSSOP-16 LLP-16 LLP-16 NSC Package Drawing MTC-16 MTC-16 SDA-16A SDA-16A Supplied As 92 Units per anti-static tube 2500 Units on Tape and Reel 1000 Units on Tape and Reel 4500 Units on Tape and Reel Pin Description PIN 1 2 NAME VIN RAMP DESCRIPTION Source Input Voltage Modulator ramp signal APPLICATION INFORMATION Input to start-up regulator. Input range 13V to 90V, with transient capability to 100V. An external RC circuit from Vin sets the ramp slope. This pin is discharged at the conclusion of every cycle by an internal FET, initiated by either the internal clock or the V*Sec Clamp comparator. 3 CS1 Current sense input for cycle-by-cycle limiting If CS1 exceeds 0.25V the outputs will go into Cycle-by-Cycle current limit. CS1 is held low for 50ns after OUT_A switches high providing leading edge blanking. Current sense input for soft restart If CS2 exceeds 0.25V the outputs will be disabled and a softstart commenced. The soft-start capacitor will be fully discharged and then released with a pull-up current of 1µA. After the first output pulse (when SS =1V), the SS charge current will revert back to 20µA. CS2 is held low for 50ns after OUT_A switches high, providing leading edge blanking. An external resistor (RSET) sets either the overlap time or dead time for the active clamp output. An RSET resistor connected between TIME and GND produces in-phase OUT_A and OUT_B pulses with overlap. An RSET resistor connected between TIME and REF produces out-of-phase OUT_A and OUT_B pulses with deadtime. Maximum output current: 10mA Locally decouple with a 0.1µF capacitor. Reference stays low until the line UVLO and the VCC UV comparators are satisfied. 4 CS2 5 TIME Output overlap/Deadtime control 6 REF Precision 5 volt reference output www.national.com 2 LM5025 Pin Description PIN 7 NAME VCC (Continued) DESCRIPTION APPLICATION INFORMATION Output from the internal high voltage start-up If an auxiliary winding raises the voltage on this pin above the regulation setpoint, the internal start-up regulator. The VCC voltage is regulated to 7.6V. regulator will shutdown, reducing the IC power dissipation. Main output driver Active Clamp output driver Power ground Analog ground Output of the main switch PWM output gate driver. Output capability of 3A peak sink current. Output of the Active Clamp switch gate driver. Capable of 1.25A peak sink current.. Connect directly to analog ground. Connect directly to power ground. For the LLP package option the exposed pad is electrically connected to AGND. An external capacitor and an internal 20µA current source set the softstart ramp. The SS current source is reduced to 1uA initially following a CS2 over-current event or an over temperature event. An internal 5KΩ resistor pull-up is provided on this pin. The external opto-coupler sinks current from COMP to control the PWM duty cycle. An external resistor connected from RT to ground sets the internal oscillator frequency. The internal oscillator can be synchronized to an external clock with a frequency 20% lower than the internal oscillator’s free running frequency. There is no constraint on the maximum sync frequency. An external voltage divider from the power source sets the shutdown comparator levels. The comparator threshold is 2.5V. Hysteresis is set by an internal current source (20µA) that is switched on or off as the UVLO pin potential crosses the 2.5V threshold. 8 9 10 11 OUT_A OUT_B PGND AGND 12 SS Soft-start control 13 COMP Input to the Pulse Width Modulator 14 15 RT SYNC Oscillator timing resistor pin Oscillator UP/DOWN synchronization input 16 UVLO Line Under-Voltage shutdown 3 www.national.com LM5025 Block Diagram Simplified Block Diagram 20086902 www.national.com 4 LM5025 Absolute Maximum Ratings (Note 1) If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. VIN to GND VCC to GND CS1, CS2 to GND All other inputs to GND ESD Rating (Note 2) Human Body Model 2kV -0.3V to 100V -0.3V to 16V -0.3 to 1.00V -0.3 to 7V Machine Model Storage Temperature Range Junction Temperature 200V -55˚C to 150˚C 150˚C Operating Ratings (Note 1) VIN Voltage External Voltage Applied to VCC Operating Junction Temperature 13 to 90V 8 to 15V -40˚C to +125˚C Electrical Characteristics Specifications with standard typeface are for TJ = 25˚C, and those with boldface type apply over full Operating Junction Temperature range. VIN = 48V, VCC = 10V, RT = 31.3kΩ, RSET = 27.4kΩ) unless otherwise stated (Note 3) Symbol Startup Regulator VCC Reg I-VIN VCC Regulation VCC Current Limit Startup Regulator Leakage (external Vcc Supply) Shutdown Current (Iin) VCC Supply VCC Under-voltage Lockout Voltage (positive going Vcc) VCC Under-voltage Hysteresis VCC Supply Current (ICC) Reference Supply VREF Ref Voltage Ref Voltage Regulation Ref Current Limit Current Limit CS1 Prop CS1 Delay to Output CS1 Step from 0 to 0.4V Time to onset of OUT Transition (90%) Cgate = 0 CS2 Step from 0 to 0.4V Time to onset of OUT Transition (90%) Cgate = 0 0.22 40 ns IREF = 0 mA IREF = 0 to 10mA 10 4.85 5 25 20 5.15 50 V mV mA Cgate = 0 VCC Reg - 220mV 1.0 VCC Reg 120mV 1.5 2.0 4.2 V No Load (Note 4) VIN = 100V 7.3 20 7.6 25 165 500 7.9 V mA µA Parameter Conditions Min Typ Max Units UVLO = 0V 350 450 µA V mA CS2 Prop CS2 Delay to Output 50 ns Cycle by Cycle Threshold Voltage (CS1) Cycle Skip Threshold Voltage (CS2) Leading Edge Blanking Time CS Sink Impedance (clocked) ICS = 10mA Resets SS capacitor; auto restart 0.25 0.28 V 0.22 0.25 50 30 0.28 V ns 50 Ω 5 www.national.com LM5025 Electrical Characteristics Symbol Soft-Start Soft-start Current Source Normal Soft-start Current Source following a CS2 event Oscillator Frequency1 Frequency2 Sync threshold Min Sync Pulse Width Sync Frequency Range PWM Comparator Delay to Output Parameter (Continued) Specifications with standard typeface are for TJ = 25˚C, and those with boldface type apply over full Operating Junction Temperature range. VIN = 48V, VCC = 10V, RT = 31.3kΩ, RSET = 27.4kΩ) unless otherwise stated (Note 3) Conditions Min 17 0.5 Typ 22 1 Max 27 1.5 Units µA µA TA = 25˚C TJ = Tlow to Thigh RT = 10.4KΩ 180 175 500 200 580 2 220 225 660 100 kHz kHz V ns kHz 160 COMP step 5V to 0V Time to onset of OUT_A transition low 0 0.7 4.3 COMP = 0V 0.6 40 ns Duty Cycle Range COMP to PWM Offset COMP Open Circuit Voltage COMP Short Circuit Current Volt x Second Clamp Ramp Clamp Level Delta RAMP measured from onset of OUT_A to Ramp peak. COMP = 5V 80 1 1.3 5.9 1 1.4 % V V mA 2.4 2.5 2.6 V UVLO Shutdown Undervoltage Shutdown Threshold Undervoltage Shutdown Hysteresis Output Section OUT_A High Saturation OUTPUT_A Peak Current Sink OUT_A Low Saturation OUTPUT_A Rise Time OUTPUT_A Fall Time OUT_B High Saturation OUTPUT_B Peak Current Sink OUT_B Low Saturation OUTPUT_B Rise Time www.national.com 2.44 16 2.5 20 2.56 24 V µA MOS Device @ Iout = -10mA, Bipolar Device @ Vcc/2 MOS Device @ Iout = 10mA, Cgate = 2.2nF Cgate = 2.2nF MOS Device @ Iout = -10mA, Bipolar Device @ Vcc/2 MOS Device @ Iout = 10mA, Cgate = 1nF 6 5 3 6 20 15 10 1 12 20 10 Ω A 9 Ω ns ns 20 Ω A 18 Ω ns LM5025 Electrical Characteristics Symbol Parameter OUTPUT_B Fall Time Output Timing Control Overlap Time (Continued) Specifications with standard typeface are for TJ = 25˚C, and those with boldface type apply over full Operating Junction Temperature range. VIN = 48V, VCC = 10V, RT = 31.3kΩ, RSET = 27.4kΩ) unless otherwise stated (Note 3) Conditions Cgate = 1nF RSET = 38 kΩ connected to GND, 50% to 50% transitions RSET = 29.5 kΩ connected to REF, 50% to 50% transitions 75 Min Typ 15 105 135 Max Units ns ns Deadtime 75 105 135 ns Thermal Shutdown TSD Thermal Shutdown Threshold Thermal Shutdown Hysteresis Thermal Resistance θJA Junction to Ambient MTC Package SDA Package 125 32 ˚C/W ˚C/W 165 25 ˚C ˚C Note 1: Absolute Maximum Ratings are limits beyond which damage to the device may occur. Operating Ratings are conditions under which operation of the device is intended to be functional. For guaranteed specifications and test conditions, see the Electrical Characteristics. Note 2: For detailed information on soldering plastic TSSOP and LLP packages, refer to the Packaging Data Book available from National Semiconductor Corporation. Note 3: All limits are guaranteed. All electrical characteristics having room temperature limits are tested during production with TA = TJ = 25˚C. All hot and cold limits are guaranteed by correlating the electrical characteristics to process and temperature variations and applying statistical process control. Note 4: Device thermal limitations may limit usable range. 7 www.national.com LM5025 Typical Performance Characteristics VCC Regulator Start-up Characteristics, VCC vs Vin VCC vs ICC 20086903 20086904 VREF vs IREF Oscillator Frequency vs RT 20086905 20086906 Overlap Time vs RSET Overlap Time vs Temperature RSET = 38K 20086907 20086908 www.national.com 8 LM5025 Typical Performance Characteristics Dead Time vs RSET (Continued) Dead Time vs Temperature RSET = 29.5K 20086909 20086910 SS Pin Current vs Temperature 20086911 9 www.national.com LM5025 Detailed Operating Description The LM5025 PWM controller contains all of the features necessary to implement power converters utilizing the Active Clamp Reset technique. The device can be configured to control either a P-Channel clamp switch or an N-Channel clamp switch. With the active clamp technique higher efficiencies and greater power densities can be realized compared to conventional catch winding or RDC clamp / reset techniques. Two control outputs are provided, the main power switch control (OUT_A) and the active clamp switch control (OUT_B). The active clamp output can be configured for either a guaranteed overlap time (for P-Channel switch applications) or a guaranteed dead time (for N_Channel applications). The two internal compound gate drivers parallel both MOS and Bipolar devices, providing superior gate drive characteristics. This controller is designed for highspeed operation including an oscillator frequency range up to 1MHz and total PWM and current sense propagation delays less than 100ns. The LM5025 includes a high-voltage start-up regulator that operates over a wide input range of 13V to 90V. Additional features include: Line Under Voltage Lockout (UVLO), softstart, oscillator UP/DOWN sync capability, precision reference and thermal shutdown. An external start-up regulator or other bias rail can be used instead of the internal start-up regulator by connecting the VCC and the VIN pins together and feeding the external bias voltage into the two pins. Line Under-Voltage Detector The LM5025 contains a line Under Voltage Lock Out (UVLO) circuit. An external set-point voltage divider from Vin to GND, sets the operational range of the converter. The divider must be designed such that the voltage at the UVLO pin will be greater than 2.5V when Vin is in the desired operating range. If the undervoltage threshold is not met, all functions of the controller are disabled and the controller remains in a low power standby state. UVLO hysteresis is accomplished with an internal 20uA current source that is switched on or off into the impedance of the set-point divider. When the UVLO threshold is exceeded, the current source is activated to instantly raise the voltage at the UVLO pin. When the UVLO pin voltage falls below the 2.5V threshold, the current source is turned off causing the voltage at the UVLO pin to fall. The UVLO pin can also be used to implement a remote enable / disable function. Pulling the UVLO pin below the 2.5V threshold disables the converter. High Voltage Start-Up Regulator The LM5025 contains an internal high voltage start-up regulator that allows the input pin (VIN) to be connected directly to the line voltage. The regulator output is internally current limited to 20mA. When power is applied, the regulator is enabled and sources current into an external capacitor connected to the VCC pin. The recommended capacitance range for the VCC regulator is 0.1µF to 100µF. When the voltage on the VCC pin reaches the regulation point of 7.6V and the internal voltage reference (REF) reaches its regulation point of 5V, the controller outputs are enabled. The outputs will remain enabled until VCC falls below 6.2V or the line Under Voltage Lock Out detector indicates that VIN is out of range. In typical applications, an auxiliary transformer winding is connected through a diode to the VCC pin. This winding must raise the VCC voltage above 8V to shut off the internal start-up regulator. Powering VCC from an auxiliary winding improves efficiency while reducing the controller power dissipation. The external VCC capacitor must be sized such that the capacitor and VCC self-bias will maintain a VCC voltage greater than 6.2V during the initial start-up. During a fault mode when the converter auxiliary winding is inactive, external current draw on the VCC line should be limited so the power dissipated in the start-up regulator does not exceed the maximum power dissipation of the controller. PWM Outputs The relative phase of the main (OUT_A) and active clamp outputs (OUT_B) can be configured for the specific application. For active clamp configurations utilizing a ground referenced P-Channel clamp switch, the two outputs should be in phase with the active clamp output overlapping the main output. For active clamp configurations utilizing a high side N-Channel switch, the active clamp output should be out of phase with main output and there should be a dead time between the two gate drive pulses. A distinguishing feature of the LM5025 is the ability to accurately configure either dead time (both off) or overlap time (both on) of the gate driver outputs. The overlap / deadtime magnitude is controlled by the resistor value connected to the TIME pin of the controller. The opposite end of the resistor can be connected to either REF for deadtime control or GND for overlap control. The internal configuration detector senses the connection and configures the phase relationship of the main and active clamp outputs. The magnitude of the overlap/dead time can be calculated as follows: Overlap Time (ns) = 2.8 x RSET - 1.2 Dead Time (ns) = 2.9 x RSET +20 RSET in kΩ, Time in ns www.national.com 10 LM5025 PWM Outputs (Continued) 20086912 FIGURE 1. Compound Gate Drivers The LM5025 contains two unique compound gate drivers, which parallel both MOS and Bipolar devices to provide high drive current throughout the entire switching event. The Bipolar device provides most of the drive current capability and provides a relatively constant sink current which is ideal for driving large power MOSFETs. As the switching event nears conclusion and the Bipolar device saturates, the internal MOS device continues to provide a low impedance to compete the switching event. During turn-off at the Miller plateau region, typically around 2V - 3V, is where gate driver current capability is needed most. The resistive characteristics of all MOS gate drivers are adequate for turn-on since the supply to output voltage differential is fairly large at the Miller region. During turn-off however, the voltage differential is small and the current source characteristic of the Bipolar gate driver is beneficial to provide fast drive capability. the internal 5V reference and COMP, can be used as the pull-up for an optocoupler. The comparator polarity is such that 0V on the COMP pin will produce a zero duty cycle on both gate driver outputs. Volt Second Clamp The Volt x Second Clamp comparator compares the ramp signal (RAMP) to a fixed 2.5V reference. By proper selection of RFF and CFF, the maximum ON time of the main switch can be set to the desired duration. The ON time set by Volt x Second Clamp varies inversely with the line voltage because the RAMP capacitor is charged by a resistor connected to Vin while the threshold of the clamp is a fixed voltage (2.5V). An example will illustrate the use of the Volt x Second Clamp comparator to achieve a 50% duty cycle limit, at 200KHz, at a 48V line input: A 50% duty cycle at a 200KHz requires a 2.5µs of ON time. At 48V input the Volt x Second product is 120V x µs (48V x 2.5µs). To achieve this clamp level: RFF x CFF = VIN x TON / 2.5V 48 x 2.5µ / 2.5 = 48µ Select CFF = 470pF RFF = 102kΩ The recommended capacitor value range for CFF is 100pF to 1000pF. The CFF ramp capacitor is discharged at the conclusion of every cycle by an internal discharge switch controlled by either the internal clock or by the V x S Clamp comparator, whichever event occurs first. Current Limit 20086913 PWM Comparator The PWM comparator compares the ramp signal (RAMP) to the loop error signal (COMP). This comparator is optimized for speed in order to achieve minimum controllable duty cycles. The internal 5kΩ pull-up resistor, connected between 11 The LM5025 contains two modes of over-current protection. If the sense voltage at the CS1 input exceeds 0.25V the present power cycle is terminated (cycle-by-cycle current limit). If the sense voltage at the CS2 input exceeds 0.25V, the controller will terminate the present cycle, discharge the softstart capacitor and reduce the softstart current source to 1µA. The softstart (SS) capacitor is released after being fully discharged and slowly charges with a 1µA current source. When the voltage at the SS pin reaches approximately 1V, www.national.com LM5025 Current Limit (Continued) the PWM comparator will produce the first output pulse at OUT_A. After the first pulse occurs, the softstart current source will revert to the normal 20µA level. Fully discharging and then slowly charging the SS capacitor protects a continuously over-loaded converter with a low duty cycle hiccup mode. These two modes of over-current protection allow the user great flexibility to configure the system behavior in over-load conditions. If it is desired for the system to act as a current source during an over-load, then the CS1 cycle-by-cycle current limiting should be used. In this case the current sense signal should be applied to the CS1 input and the CS2 input should be grounded. If during an overload condition it is desired for the system to briefly shutdown, followed by softstart retry, then the CS2 hiccup current limiting mode should be used. In this case the current sense signal should be applied to the CS2 input and the CS1 input should be grounded. This shutdown / soft-start retry will repeat indefinitely while the over-load condition remains. The hiccup mode will greatly reduce the thermal stresses to the system during heavy overloads. The cycle-by-cycle mode will have higher system thermal dissipations during heavy overloads, but provides the advantage of continuous operation for short duration overload conditions. In some systems it is possible utilize both modes concurrently, whereby slight overload conditions activate the CS1 cycle-by cycle mode while more severe overloading activates the CS2 hiccup mode. Operating both modes concurrently, requires that the slope of the inductor current be sufficient to reach the CS2 threshold before the CS1 function turns off the main output switch. This requires a high dv/dt at the current sense pin. The signal must be fast enough to reach the second level threshold before the first threshold detector (CS1) turns off the gate driver. Excessive filtering on the CS pin, an extremely low value current sense resistor or an inductor that does not saturate with excessive loading may prevent the second level threshold from ever being reached. A small RC filter, located near the controller, is recommended for each of the CS pins. Each CS input has an internal FET which discharges the current sense filter capacitor at the conclusion of every cycle, to improve dynamic performance. This same FET remains on an additional 50ns at the start of each main switch cycle to attenuate the leading edge spike in the current sense signal. The LM5025 CS comparators are very fast and may respond to short duration noise pulses. Layout considerations are critical for the current sense filter and sense resistor. The capacitor associated with the CS filter must be placed very close to the device and connected directly to the pins of the IC (CS and GND). If a current sense transformer is used, both leads of the transformer secondary should be routed to the filter network , which should be located close to the IC. If a sense resistor in the source of the main switch MOSFET is used for current sensing, a low inductance type of resistor is required. When designing with a current sense resistor, all of the noise sensitive low power ground connections should be connected together near the IC GND and a single connection should be made to the power ground (sense resistor ground point). 20086914 Oscillator and Sync Capability The LM5025 oscillator is set by a single external resistor connected between the RT pin and GND. To set a desired oscillator frequency (F), the necessary RT resistor can be calculated from: RT = (5725/F)1.026 where F is in kHz and RT in kΩ. The RT resistor should be located very close to the device and connected directly to the pins of the IC (RT and GND). A unique feature of LM5025 is the ability to synchronize the oscillator to an external clock with a frequency that is either higher or lower than the frequency of the internal oscillator. The lower frequency sync frequency range is 80% of the free running internal oscillator frequency. There is no constraint on the maximum SYNC frequency. A minimum pulse width of 100ns is required for the synchronization clock . If the synchronization feature is not required, the SYNC pin should be connected to GND to prevent any abnormal interference . The internal oscillator can be completely disabled by connecting the RT pin to REF. Once disabled, the sync signal www.national.com 12 will act directly as the master clock for the controller. Both the frequency and the maximum duty cycle of the PWM controller can be controlled by the SYNC signal (within the limitations of the Volt x Second Clamp). The maximum duty cycle (D) will be (1-D) of the SYNC signal. Feed-Forward Ramp An external resistor (RFF) and capacitor (CFF) connected to VIN and GND are required to create the PWM ramp signal. The slope of the signal at the RAMP pin will vary in proportion to the input line voltage. This varying slope provides line feedforward information necessary to improve line transient response with voltage mode control. The RAMP signal is compared to the error signal at the COMP pin by the pulse width modulator comparator to control the duty cycle of the main switch output. The Volt Second Clamp comparator also monitors the RAMP pin and if the ramp amplitude exceeds 2.5V the present cycle is terminated. The ramp signal is reset to GND at the end of each cycle by either the internal clock or the Volt Second comparator,which ever occurs first. LM5025 Soft-start The softstart feature allows the power converter to gradually reach the initial steady state operating point, thus reducing start-up stresses and surges. At power on, a 20µA current is sourced out of the softstart pin (SS) into an external capacitor. The capacitor voltage will ramp up slowly and will limit the COMP pin voltage and therefore the PWM duty cycle. In the event of a fault as determined by VCC undervoltage, line undervoltage (UVLO) or second level current limit, the output gate drivers are disabled and the softstart capacitor is fully discharged. When the fault condition is no longer present a softstart sequence will be initiated. Following a second level current limit detection (CS2), the softstart current source is reduced to 1µA until the first output pulse is generated by the PWM comparator. The current source returns to the nominal 20µA level after the first output pulse (~1V at the SS pin). Thermal Protection Internal Thermal Shutdown circuitry is provided to protect the integrated circuit in the event the maximum junction temperature is exceeded. When activated, typically at 165˚C, the controller is forced into a low power standby state with the output drivers and the bias regulator disabled. The device will restart after the thermal hysteresis (typically 25˚C). During a restart after thermal shutdown, the softstart capacitor will be fully discharged and then charged in the low current mode (1µA) similar to a second level current limit event. The thermal protection feature is provided to prevent catastrophic failures from accidental device overheating. 13 www.national.com LM5025 www.national.com 20086917 Application Circuit: Input 36-78V, Output 3.3V, 30A 14 LM5025 Physical Dimensions unless otherwise noted inches (millimeters) Molded TSSOP-16 NS Package Number MTC16 Note: It is recommended that the exposed pad be connected to Pin 11 (AGND) 16-Lead LLP Surface Mount Package NS Package Number SDA16A 15 www.national.com LM5025 Active Clamp Voltage Mode PWM Controller Notes LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. BANNED SUBSTANCE COMPLIANCE National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2. National Semiconductor Americas Customer Support Center Email: new.feedback@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Customer Support Center Fax: +49 (0) 180-530 85 86 Email: europe.support@nsc.com Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 National Semiconductor Asia Pacific Customer Support Center Email: ap.support@nsc.com National Semiconductor Japan Customer Support Center Fax: 81-3-5639-7507 Email: jpn.feedback@nsc.com Tel: 81-3-5639-7560 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
LM5025SD 价格&库存

很抱歉,暂时无法提供与“LM5025SD”相匹配的价格&库存,您可以联系我们找货

免费人工找货