0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MMG20271HT1

MMG20271HT1

  • 厂商:

    NXP(恩智浦)

  • 封装:

    VFQFN12_EP

  • 描述:

    IC DRVR AMP HI LINEARITY QFN12

  • 数据手册
  • 价格&库存
MMG20271HT1 数据手册
Page 1 of 6 FSL Logo PRODUCT AND PROCESS CHANGE NOTIFICATION Generic Copy This notice is NXP Confidential Proprietary and is only intended for the customer listed on this notification. ISSUE DATE: NOTIFICATION: TITLE: EFFECTIVE DATE: 03-Jun-2016 17193 Second Source Assembly for RF PQFN/MLF Product Lines 15-Jul-2016 DEVICE(S) MPN MMA20312BT1 MMA20312BVT1 MMDS09254HT1 MMDS20254HT1 MMDS25254HT1 MMG20271HT1 MMG3006NT1 MML09211HT1 MML09212HT1 MML09231HT1 MML20211HT1 MML20242HT1 MMT20303HT1 MMZ09312BT1 MMZ09332BT1 MMZ25332B4T1 MMZ25332BT1 MMZ25333BT1 MMZ27333BT1 This notice is NXP Confidential Proprietary and is only intended for the customer listed on this notification. AFFECTED CHANGE CATEGORIES • ASSEMBLY SITE DESCRIPTION OF CHANGE http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm 6/6/2016 Page 2 of 6 This is a notification of NXP’s qualifying ofsecond assembly site for RF PQFN/MLF packages. This formal notification describes the qualification process. Qualification schedules by device, as well as reliability and electrical results are provided in the PCN. All electrical and reliability data is shown for qualification vehicles and schedule for sample availability is also included. Qualification dates are based on current orders and forecasts and are subject to change without notice after PCN expiration. There is no change in fit, form, or function with the new assembly site. Part Estimated 2nd Assembly Qualification Sample Date REASON FOR CHANGE MML09211H Jul - 16 Aug - 16 MML20211H Jul - 16 Aug - 16 Qualification of second MML09231H Jul - 16 Aug - 16 assembly site. MMG20271H Jul - 16 Aug - 16 MML09212H Jul - 16 Aug - 16 MML20242H Jul - 16 Aug - 16 ANTICIPATED MMZ09312B Jul - 16 Aug - 16 IMPACT OF MMA20312B Jul - 16 Aug - 16 PRODUCT CHANGE MMA20312BV Jul - 16 Aug - 16 (FORM, FIT, FUNCTION, OR MMZ25332B Jul - 16 Aug - 16 RELIABILITY) MMZ09332B Jul - 16 Aug - 16 MMT20303H Jul - 16 Aug - 16 None. MMZ25332B4 Jul - 16 Aug - 16 MMZ25333B Jul - 16 Aug - 16 MMZ27333B Jul - 16 Aug - 16 MMG3006N Jul - 16 Aug - 16 According to JEDEC MMDS09254H Jul - 16 Aug - 16 Standard JESD46, MMDS20254H Jul - 16 Aug - 16 lack of MMDS36254H Jul - 16 Aug - 16 acknowledgement of MMDS25254H Jul - 16 Aug - 16 this PCN within 30 days will be considered acceptance of change. To request further data or inquire about the notification, please enter a Support Case. Be aware that after you select this link to enter your request, you must choose the topic "Product Change Notification" once on the Salesforce page. For sample inquiries - please go to www.nxp.com QUAL DATA AVAILABILITY DATE: QUALIFICATION STATUS: 03-Nov-2016 N/A QUALIFICATION PLAN: http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm 6/6/2016 Page 3 of 6 1st Qual Vehicle Reliability Test Plan Reliability Test THB 2nd Assy Site Lot 1 25 2nd Assy Site Lot 2 25 Temp Cycle HTSL Electricals Wire Pull Die Attach 25 25 100 5 10 25 25 100 5 10 2nd Assy Site Lot 3 25 Original Assy Site Control Lot 25 25 25 100 5 10 25 25 Historical 5 10 Original Assy Site Control Lot Historical 5 10 2nd Qual Vehicle Reliability Test Plan Reliability Test 2nd Assy Site Lot 1 2nd Assy Site Lot 2 2nd Assy Site Lot 3 Electricals Wire Pull Die Attach 100 5 10 100 5 10 100 5 10 3rd Qual Vehicle Reliability Test Plan Reliability Test 2nd Assy Site Lot 1 2nd Assy Site Lot 2 THB Temp Cycle HTSL Electricals Wire Pull Die Attach 25 25 77 100 5 10 25 25 77 100 5 10 2nd Assy Site Lot 1 2nd Assy Site Lot 2 2nd Assy Site Lot 3 Original Assy Site Control Lot 25 25 25 25 100 5 10 Historical 5 10 2nd Assy Site Lot 3 Original Assy Site Control Lot 4th Qual Vehicle Reliability Test Plan Reliability Test http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm 6/6/2016 Page 4 of 6 THB 25 25 25 25 Temp Cycle HTSL Electricals Wire Pull Die Attach 25 77 100 5 10 25 77 100 5 10 25 25 100 5 10 Historical 5 10 Reliability Test THB 2nd Assy Site Lot 1 25 2nd Assy Site Lot 2 25 2nd Assy Site Lot 3 25 Original Assy Controls 25 Temp Cycle 25 25 25 25 HTSL Electricals Wire Pull Die Attach 25 100 5 10 25 100 5 10 25 100 5 10 25 Historical 5 10 RELIABILITY DATA SUMMARY: Reliability Data Summary 1st Qual Vehicle Results Pass (504hr) Pass (500 cycles) Pass (1008hr) Pass Pass Pass Reliability Data Summary 2nd Qual Vehicle Reliability Test Electricals Wire Pull Die Attach 2nd Assy Site Lot 1 100 5 10 2nd Assy Site Lot 2 100 5 10 2nd Assy Site Lot 3 100 5 10 Original Assy Controls Historical 5 10 Results Pass Pass Pass Reliability Data Summary – 3rd Qual Vehicle Reliability Test THB 2nd Assy Site Lot 1 25 2nd Assy Site Lot 2 25 2nd Assy Site Lot 3 25 Original Assy Controls 25 Temp Cycle HTSL Electricals 25 25 100 25 25 100 25 25 100 25 25 Historical http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm Results Pass (504hr) Pass (500 cycles) Pass (1008hr) Pass 6/6/2016 Page 5 of 6 Wire Pull Die Attach 5 10 5 10 5 10 5 10 Pass Pass 2nd Assy Site Lot 1 25 25 25 100 5 10 2nd Assy Site Lot 2 25 25 25 100 5 10 2nd Assy Site Lot 3 25 25 25 100 5 10 Original Assy Controls 25 25 25 Historical 5 10 Results July-2016 July-2016 July-2016 July-2016 July-2016 July-2016 Reliability Data Summary – 4th Qual Vehicle Reliability Test THB Temp Cycle HTSL Electricals Wire Pull Die Attach ELECTRICAL CHARACTERISTIC SUMMARY: Electrical Characteristic Summary - 1st Qual Vehicle MML09211HT1 MLF/QFN 2nd 2x2 Assembly Site S21 900MHz (dB) Avg 20.91 Std Dev 0.16 Production 20.78 0.19 Icq (mA) Avg Std Dev 61.48 1.71 64.2 1.86 Irf (mA) Avg Std Dev 64.37 1.46 66.64 1.77 Electrical Characteristic Summary – 2nd Qual Vehicle MMG3006NT1 MLF/QFN 4x4 S21 900MHz (dB) Avg Std Dev 2nd Assembly Site 14.41 0.09 Icq (mA) Avg Std Dev 832.97 9.89 Production 833.72 10.03 14.27 0.12 Electrical Characteristic Summary – 3rd Qual Vehicle http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm 6/6/2016 Page 6 of 6 MMZ25254HT1 MLF/QFN 6x6 Idd (mA) Std Dev The rest of the parameters are discrete Avg 0.31 2nd Assembly Site 11.18 0.12 Production 10.97 Electrical Characteristic Summary – 4th Qual Vehicle MMZ20312BV MLF 3x3 Production S21 2140 MHz (dB) Avg Std Dev 2nd Assembly Site 26.06 0.58 Icq (mA) Avg Std Dev 62.56 1.12 57.01 0.86 Irf (mA) Avg Std Dev 125.09 5.48 127.65 4.69 26.01 0.41 CHANGED PART IDENTIFICATION: Parts assembled at new site will be marked with a date code beginning work week 35 of 2016. SAMPLE AVAILABILITY DATE: 03-Jun-2016 ATTACHMENT(S): N/A http://cache.freescale.com/files/shared/doc/pcn/PCN17193.htm 6/6/2016
MMG20271HT1 价格&库存

很抱歉,暂时无法提供与“MMG20271HT1”相匹配的价格&库存,您可以联系我们找货

免费人工找货