0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SC16IS740IPW,112

SC16IS740IPW,112

  • 厂商:

    NXP(恩智浦)

  • 封装:

    TSSOP-16_5X4.4MM

  • 描述:

    IC UART SINGLE W/FIFO 16-TSSOP

  • 数据手册
  • 价格&库存
SC16IS740IPW,112 数据手册
SC16IS740/750/760 Single UART with I2C-bus/SPI interface, 64 bytes of transmit and receive FIFOs, IrDA SIR built-in support Rev. 7 — 9 June 2011 Product data sheet 1. General description The SC16IS740/750/760 is a slave I2C-bus/SPI interface to a single-channel high performance UART. It offers data rates up to 5 Mbit/s and guarantees low operating and sleeping current. The SC16IS750 and SC16IS760 also provide the application with 8 additional programmable I/O pins. The device comes in very small HVQFN24, TSSOP24 (SC16IS750/760) and TSSOP16 (SC16IS740) packages, which makes it ideally suitable for handheld, battery operated applications. This family of products enables seamless protocol conversion from I2C-bus or SPI to and RS-232/RS-485 and are fully bidirectional. The SC16IS760 differs from the SC16IS750 in that it supports SPI clock speeds up to 15 Mbit/s instead of the 4 Mbit/s supported by the SC16IS750, and in that it supports IrDA SIR up to 1.152 Mbit/s. In all other aspects, the SC16IS760 is functionally and electrically the same as the SC16IS750. The SC16IS740 is functionally and electrically identical to the SC16IS750, with the exception of the programmable I/O pins which are only present on the SC16IS750. The SC16IS740/750/760’s internal register set is backward-compatible with the widely used and widely popular 16C450. This allows the software to be easily written or ported from another platform. The SC16IS740/750/760 also provides additional advanced features such as auto hardware and software flow control, automatic RS-485 support, and software reset. This allows the software to reset the UART at any moment, independent of the hardware reset signal. 2. Features and benefits 2.1 General features            Single full-duplex UART Selectable I2C-bus or SPI interface 3.3 V or 2.5 V operation Industrial temperature range: 40 C to +95 C 64 bytes FIFO (transmitter and receiver) Fully compatible with industrial standard 16C450 and equivalent Baud rates up to 5 Mbit/s in 16 clock mode Auto hardware flow control using RTS/CTS Auto software flow control with programmable Xon/Xoff characters Single or double Xon/Xoff characters Automatic RS-485 support (automatic slave address detection) SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR                 Up to eight programmable I/O pins (SC16IS750 and SC16IS760 only) RS-485 driver direction control via RTS signal RS-485 driver direction control inversion Built-in IrDA encoder and decoder interface SC16IS750 supports IrDA SIR with speeds up to 115.2 kbit/s SC16IS760 supports IrDA SIR with speeds up to 1.152 Mbit/s1 Software reset Transmitter and receiver can be enabled/disabled independent of each other Receive and Transmit FIFO levels Programmable special character detection Fully programmable character formatting  5-bit, 6-bit, 7-bit or 8-bit character  Even, odd, or no parity  1, 112, or 2 stop bits Line break generation and detection Internal Loopback mode Sleep current less than 30 A at 3.3 V Industrial and commercial temperature ranges Available in HVQFN24, TSSOP24 (SC16IS750/760) and TSSOP16 (SC16IS740) packages 2.2 I2C-bus features     Noise filter on SCL/SDA inputs 400 kbit/s maximum speed Compliant with I2C-bus fast speed Slave mode only 2.3 SPI features     SC16IS750 supports 4 Mbit/s maximum SPI clock speed SC16IS760 supports 15 Mbit/s maximum SPI clock speed Slave mode only SPI Mode 0 3. Applications  Factory automation and process control  Portable and battery operated devices  Cellular data devices 1. Please note that IrDA SIR at 1.152 Mbit/s is not compatible with IrDA MIR at that speed. Please refer to application notes for usage of IrDA SIR at 1.152 Mbit/s. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 2 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 4. Ordering information Table 1. Ordering information Type number SC16IS740IPW Package Name Description Version TSSOP16 plastic thin shrink small outline package; 16 leads; body width 4.4 mm SOT403-1 SC16IS740IPW/Q900[1] TSSOP16 plastic thin shrink small outline package; 16 leads; body width 4.4 mm SOT403-1 SC16IS750IBS HVQFN24 plastic thermal enhanced very thin quad flat package; no leads; 24 terminals; body 4  4  0.85 mm SC16IS750IPW TSSOP24 plastic thin shrink small outline package; 24 leads; body width 4.4 mm SOT355-1 SC16IS760IBS HVQFN24 plastic thermal enhanced very thin quad flat package; no leads; 24 terminals; body 4  4  0.85 mm SC16IS760IPW TSSOP24 plastic thin shrink small outline package; 24 leads; body width 4.4 mm SOT355-1 [1] SOT616-3 SOT616-3 SC16IS740IPW/Q900 is AEC-Q100 compliant. Contact interface.support@nxp.com for PPAP. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 3 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 5. Block diagram VDD SC16IS750/760 RESET SCL A0 I2C-BUS A1 TX 16C450 COMPATIBLE REGISTER SETS SDA RX RTS CTS IRQ 1 kΩ (3.3 V) 1.5 kΩ (2.5 V) 4 GPIO[3:0] VDD VDD GPIO REGISTER I2C/SPI GPIO4/DSR GPIO5/DTR GPIO6/CD GPIO7/RI XTAL1 Fig 1. XTAL2 VSS 002aab014 Block diagram of SC16IS750/760 I2C-bus interface VDD SC16IS740 RESET SCL SDA A0 I2C-BUS A1 16C450 COMPATIBLE REGISTER SETS TX RX RTS CTS IRQ 1 kΩ (3.3 V) 1.5 kΩ (2.5 V) VDD VDD I2C/SPI XTAL1 Fig 2. SC16IS740_750_760 Product data sheet XTAL2 VSS 002aab971 Block diagram of SC16IS740 I2C-bus interface All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 4 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR VDD SC16IS750/760 RESET SCLK SO SPI SI TX 16C450 COMPATIBLE REGISTER SETS CS RX RTS CTS IRQ 1 kΩ (3.3 V) 1.5 kΩ (2.5 V) 4 GPIO[3:0] VDD GPIO REGISTER I2C/SPI GPIO4/DSR GPIO5/DTR GPIO6/CD GPIO7/RI XTAL1 Fig 3. XTAL2 VSS 002aab396 Block diagram of SC16IS750/760 SPI interface VDD SC16IS740 RESET SCLK 16C450 COMPATIBLE REGISTER SETS CS SO SPI SI TX RX RTS CTS IRQ 1 kΩ (3.3 V) 1.5 kΩ (2.5 V) VDD I2C/SPI XTAL1 Fig 4. SC16IS740_750_760 Product data sheet XTAL2 VSS 002aab972 Block diagram of SC16IS740 SPI interface All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 5 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 6. Pinning information 6.1 Pinning VDD 1 16 XTAL2 VDD 1 16 XTAL2 A0 2 15 XTAL1 CS 2 15 XTAL1 A1 3 14 RESET SI 3 14 RESET n.c. 4 13 RX SO 4 SCL 5 SCLK 5 SDA 6 11 CTS VSS 6 11 CTS IRQ 7 10 RTS IRQ 7 10 RTS I2C 8 SPI 8 SC16IS740IPW SC16IS740IPW/Q900 12 TX 9 VSS 13 RX SC16IS740IPW SC16IS740IPW/Q900 12 TX 9 002aab973 002aab974 a. I2C-bus interface Fig 5. b. SPI interface Pin configuration for TSSOP16 CTS 1 24 RTS CTS 1 24 RTS TX 2 23 GPIO7/RI TX 2 23 GPIO7/RI RX 3 22 GPIO6/CD RX 3 22 GPIO6/CD RESET 4 21 GPIO5/DTR RESET 4 21 GPIO5/DTR XTAL1 5 20 GPIO4/DSR XTAL1 5 20 GPIO4/DSR XTAL2 6 XTAL2 6 VDD 7 19 VSS 18 GPIO3 VDD 7 I2C 8 17 GPIO2 SPI 8 17 GPIO2 A0 9 16 GPIO1 CS 9 16 GPIO1 A1 10 15 GPIO0 SI 10 15 GPIO0 SC16IS750IPW SC16IS760IPW SC16IS750IPW SC16IS760IPW 19 VSS 18 GPIO3 n.c. 11 14 IRQ SO 11 14 IRQ SCL 12 13 SDA SCLK 12 13 VSS 002aab016 002aab399 a. I2C-bus interface Fig 6. VSS b. SPI interface Pin configuration for TSSOP24 SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 6 of 63 SC16IS740/750/760 NXP Semiconductors 19 GPIO6/CD 20 GPIO7/RI 21 RTS RESET 1 18 GPIO5/DTR RESET 1 XTAL1 2 17 GPIO4/DSR XTAL1 2 XTAL2 3 16 VSS XTAL2 3 VDD 4 15 GPIO3 VDD 4 I2C 5 14 GPIO2 SPI 5 14 GPIO2 A0 6 13 GPIO1 CS 6 13 GPIO1 18 GPIO5/DTR 17 GPIO4/DSR 16 VSS 15 GPIO3 GPIO0 12 9 SCLK IRQ 11 8 002aab015 VSS 10 7 SI SC16IS750IBS SC16IS760IBS SO GPIO0 12 9 SCL IRQ 11 8 SDA 10 7 A1 n.c. SC16IS750IBS SC16IS760IBS Transparent top view 002aab401 Transparent top view a. I2C-bus interface Fig 7. 22 CTS terminal 1 index area 23 TX 24 RX 19 GPIO6/CD 20 GPIO7/RI 21 RTS 22 CTS terminal 1 index area 23 TX 24 RX Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR b. SPI interface Pin configuration for HVQFN24 6.2 Pin description Table 2. Symbol Pin description Pin Type Description TSSOP16 TSSOP24 HVQFN24 CTS 11 1 22 I UART clear to send (active LOW). A logic 0 (LOW) on the CTS pin indicates the modem or data set is ready to accept transmit data from the SC16IS740/750/760. Status can be tested by reading MSR[4]. This pin only affects the transmit and receive operations when auto CTS function is enabled via the Enhanced Feature Register EFR[7] for hardware flow control operation. TX 12 2 23 O UART transmitter output. During the local Loopback mode, the TX output pin is disabled and TX data is internally connected to the UART RX input. RX 13 3 24 I UART receiver input. During the local Loopback mode, the RX input pin is disabled and TX data is connected to the UART RX input internally. RESET 14 4 1 I device hardware reset (active LOW)[1] XTAL1 15 5 2 I Crystal input or external clock input. Functions as a crystal input or as an external clock input. A crystal can be connected between XTAL1 and XTAL2 to form an internal oscillator circuit (see Figure 16). Alternatively, an external clock can be connected to this pin. XTAL2 16 6 3 O Crystal output or clock output. (See also XTAL1.) XTAL2 is used as a crystal oscillator output. VDD 1 7 4 - power supply I2C/SPI 8 8 5 I I2C-bus or SPI interface select. I2C-bus interface is selected if this pin is at logic HIGH. SPI interface is selected if this pin is at logic LOW. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 7 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 2. Symbol Pin description …continued Pin Type Description TSSOP16 TSSOP24 HVQFN24 CS/A0 2 9 6 I SPI chip select or I2C-bus device address select A0. If SPI configuration is selected by I2C/SPI pin, this pin is the SPI chip select pin (Schmitt-trigger, active LOW). If I2C-bus configuration is selected by I2C/SPI pin, this pin along with A1 pin allows user to change the device’s base address. SI/A1 3 10 7 I SPI data input pin or I2C-bus device address select A1. If SPI configuration is selected by I2C/SPI pin, this is the SPI data input pin. If I2C-bus configuration is selected by I2C/SPI pin, this pin along with A0 pin allows user to change the device’s base address. To select the device address, please refer to Table 32. SO 4 11 8 O SPI data output pin. If SPI configuration is selected by I2C/SPI pin, this is a 3-stateable output pin. If I2C-bus configuration is selected by I2C/SPI pin, this pin function is undefined and must be left as n.c. (not connected). SCL/SCLK 5 12 9 I I2C-bus or SPI input clock. SDA 6 13 10 I/O I2C-bus data input/output, open-drain if I2C-bus configuration is selected by I2C/SPI pin. If SPI configuration is selected then this pin is an undefined pin and must be connected to VSS. IRQ 7 14 11 O Interrupt (open-drain, active LOW). Interrupt is enabled when interrupt sources are enabled in the Interrupt Enable Register (IER). Interrupt conditions include: change of state of the input pins, receiver errors, available receiver buffer data, available transmit buffer space, or when a modem status flag is detected. An external resistor (1 k for 3.3 V, 1.5 k for 2.5 V) must be connected between this pin and VDD. GPIO0 - 15 12 I/O programmable I/O pin[2] GPIO1 - 16 13 I/O programmable I/O pin[2] GPIO2 - 17 14 I/O programmable I/O pin[2] GPIO3 - 18 15 I/O programmable I/O pin[2] GPIO4/DSR - 20 17 I/O programmable I/O pin or modem’s DSR pin[2][3] GPIO5/DTR - 21 18 I/O programmable I/O pin or modem’s DTR pin[2][3] GPIO6/CD - 22 19 I/O programmable I/O pin or modem’s CD pin[2][3] GPIO7/RI - 23 20 I/O programmable I/O pin or modem’s RI pin[2][3] RTS 10 24 21 O UART request to send (active LOW). A logic 0 on the RTS pin indicates the transmitter has data ready and waiting to send. Writing a logic 1 in the modem control register MCR[1] will set this pin to a logic 0, indicating data is available. After a reset this pin is set to a logic 1. This pin only affects the transmit and receive operations when auto RTS function is enabled via the Enhanced Feature Register (EFR[6]) for hardware flow control operation. VSS 9 19 16[4] - ground VSS - - center pad[4] - The center pad on the back side of the HVQFN24 package is metallic and should be connected to ground on the printed-circuit board. [1] See Section 7.4.1 “Hardware reset, Power-On Reset (POR) and software reset” [2] These pins have an active pull-up resistor at their inputs. See Table 36. [3] Selectable with IOControl register bit 1. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 8 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR [4] HVQFN24 package die supply ground is connected to both VSS pins and exposed center pad. VSS pins must be connected to supply ground for proper device operation. For enhanced thermal, electrical, and board level performance, the exposed pad needs to be soldered to the board using a corresponding thermal pad on the board and for proper heat conduction through the board, thermal vias need to be incorporated in the PCB in the thermal pad region. 7. Functional description The UART will perform serial-to-I2C conversion on data characters received from peripheral devices or modems, and I2C-to-serial conversion on data characters transmitted by the host. The complete status the SC16IS740/750/760 UART can be read at any time during functional operation by the host. The SC16IS740/750/760 can be placed in an alternate mode (FIFO mode) relieving the host of excessive software overhead by buffering received/transmitted characters. Both the receiver and transmitter FIFOs can store up to 64 characters (including three additional bits of error status per character for the receiver FIFO) and have selectable or programmable trigger levels. The SC16IS740/750/760 has selectable hardware flow control and software flow control. Hardware flow control significantly reduces software overhead and increases system efficiency by automatically controlling serial data flow using the RTS output and CTS input signals. Software flow control automatically controls data flow by using programmable Xon/Xoff characters. The UART includes a programmable baud rate generator that can divide the timing reference clock input by a divisor between 1 and (216 – 1). 7.1 Trigger levels The SC16IS740/750/760 provides independently selectable and programmable trigger levels for both receiver and transmitter interrupt generation. After reset, both transmitter and receiver FIFOs are disabled and so, in effect, the trigger level is the default value of one character. The selectable trigger levels are available via the FCR. The programmable trigger levels are available via the TLR. If TLR bits are cleared then selectable trigger level in FCR is used. If TLR bits are not cleared then programmable trigger level in TLR is used. 7.2 Hardware flow control Hardware flow control is comprised of auto CTS and auto RTS (see Figure 8). Auto CTS and auto RTS can be enabled/disabled independently by programming EFR[7:6]. With auto CTS, CTS must be active before the UART can transmit data. Auto RTS only activates the RTS output when there is enough room in the FIFO to receive data and de-activates the RTS output when the RX FIFO is sufficiently full. The halt and resume trigger levels in the TCR determine the levels at which RTS is activated/deactivated. If TCR bits are cleared then selectable trigger levels in FCR are used in place of TCR. If both auto CTS and auto RTS are enabled, when RTS is connected to CTS, data transmission does not occur unless the receiver FIFO has empty space. Thus, overrun errors are eliminated during hardware flow control. If not enabled, overrun errors occur if the transmit data rate exceeds the receive FIFO servicing latency. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 9 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR UART 1 UART 2 SERIAL TO PARALLEL RX TX PARALLEL TO SERIAL RX FIFO TX FIFO FLOW CONTROL RTS PARALLEL TO SERIAL TX CTS RX FLOW CONTROL SERIAL TO PARALLEL TX FIFO RX FIFO CTS FLOW CONTROL RTS FLOW CONTROL 002aab656 Fig 8. Autoflow control (auto RTS and auto CTS) example 7.2.1 Auto RTS Figure 9 shows RTS functional timing. The receiver FIFO trigger levels used in auto RTS are stored in the TCR or FCR. RTS is active if the RX FIFO level is below the halt trigger level in TCR[3:0]. When the receiver FIFO halt trigger level is reached, RTS is deasserted. The sending device (for example, another UART) may send an additional character after the trigger level is reached (assuming the sending UART has another character to send) because it may not recognize the deassertion of RTS until it has begun sending the additional character. RTS is automatically reasserted once the receiver FIFO reaches the resume trigger level programmed via TCR[7:4]. This reassertion allows the sending device to resume transmission. RX start character N stop start character N+1 stop start RTS receive FIFO read 1 2 N N+1 002aab040 (1) N = receiver FIFO trigger level. (2) The two blocks in dashed lines cover the case where an additional character is sent, as described in Section 7.2.1 Fig 9. RTS functional timing SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 10 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 7.2.2 Auto CTS Figure 10 shows CTS functional timing. The transmitter circuitry checks CTS before sending the next data byte. When CTS is active, the transmitter sends the next byte. To stop the transmitter from sending the following byte, CTS must be deasserted before the middle of the last stop bit that is currently being sent. The auto CTS function reduces interrupts to the host system. When flow control is enabled, CTS level changes do not trigger host interrupts because the device automatically controls its own transmitter. Without auto CTS, the transmitter sends any data present in the transmit FIFO and a receiver overrun error may result. TX start bit 0 to bit 7 start stop bit 0 to bit 7 stop CTS 002aab041 (1) When CTS is LOW, the transmitter keeps sending serial data out. (2) When CTS goes HIGH before the middle of the last stop bit of the current character, the transmitter finishes sending the current character, but it does not send the next character. (3) When CTS goes from HIGH to LOW, the transmitter begins sending data again. Fig 10. CTS functional timing 7.3 Software flow control Software flow control is enabled through the enhanced feature register and the Modem Control Register. Different combinations of software flow control can be enabled by setting different combinations of EFR[3:0]. Table 3 shows software flow control options. Table 3. Software flow control options (EFR[3:0]) EFR[3] EFR[2] EFR[1] EFR[0] TX, RX software flow control 0 0 X X no transmit flow control 1 0 X X transmit Xon1, Xoff1 0 1 X X transmit Xon2, Xoff2 1 1 X X transmit Xon1 and Xon2, Xoff1 and Xoff2 X X 0 0 no receive flow control X X 1 0 receiver compares Xon1, Xoff1 X X 0 1 receiver compares Xon2, Xoff2 1 0 1 1 transmit Xon1, Xoff1 receiver compares Xon1 or Xon2, Xoff1 or Xoff2 0 1 1 1 transmit Xon2, Xoff2 receiver compares Xon1 or Xon2, Xoff1 or Xoff2 1 1 1 1 transmit Xon1 and Xon2, Xoff1 and Xoff2 0 0 1 1 no transmit flow control receiver compares Xon1 and Xon2, Xoff1 and Xoff2 receiver compares Xon1 and Xon2, Xoff1 and Xoff2 SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 11 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR There are two other enhanced features relating to software flow control: • Xon Any function (MCR[5]): Receiving any character will resume operation after recognizing the Xoff character. It is possible that an Xon1 character is recognized as an Xon Any character, which could cause an Xon2 character to be written to the RX FIFO. • Special character (EFR[5]): Incoming data is compared to Xoff2. Detection of the special character sets the Xoff interrupt (IIR[4]) but does not halt transmission. The Xoff interrupt is cleared by a read of the IIR. The special character is transferred to the RX FIFO. 7.3.1 RX When software flow control operation is enabled, the SC16IS740/750/760 will compare incoming data with Xoff1/Xoff2 programmed characters (in certain cases, Xoff1 and Xoff2 must be received sequentially). When the correct Xoff characters are received, transmission is halted after completing transmission of the current character. Xoff detection also sets IIR[4] (if enabled via IER[5]) and causes IRQ to go LOW. To resume transmission, an Xon1/Xon2 character must be received (in certain cases Xon1 and Xon2 must be received sequentially). When the correct Xon characters are received, IIR[4] is cleared, and the Xoff interrupt disappears. 7.3.2 TX Xoff1/Xoff2 character is transmitted when the RX FIFO has passed the HALT trigger level programmed in TCR[3:0] or the selectable trigger level in FCR[7:6] Xon1/Xoff2 character is transmitted when the RX FIFO reaches the RESUME trigger level programmed in TCR[7:4] or RX FIFO falls below the lower selectable trigger level in FCR[7:6]. The transmission of Xoff/Xon(s) follows the exact same protocol as transmission of an ordinary character from the FIFO. This means that even if the word length is set to be 5, 6, or 7 bits, then the 5, 6, or 7 least significant bits of XOFF1/XOFF2 or XON1/XON2 will be transmitted. (Note that the transmission of 5, 6, or 7 bits of a character is seldom done, but this functionality is included to maintain compatibility with earlier designs.) It is assumed that software flow control and hardware flow control will never be enabled simultaneously. Figure 11 shows an example of software flow control. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 12 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR UART1 UART2 TRANSMIT FIFO RECEIVE FIFO data PARALLEL-TO-SERIAL SERIAL-TO-PARALLEL Xoff–Xon–Xoff SERIAL-TO-PARALLEL PARALLEL-TO-SERIAL Xon1 WORD Xon1 WORD Xon2 WORD Xon2 WORD Xoff1 WORD Xoff1 WORD Xoff2 WORD compare programmed Xon-Xoff characters Xoff2 WORD 002aaa229 Fig 11. Example of software flow control 7.4 Reset and power-on sequence 7.4.1 Hardware reset, Power-On Reset (POR) and software reset These three reset methods are identical and will reset the internal registers as indicated in Table 4. Table 4 summarizes the state of register. Table 4. SC16IS740_750_760 Product data sheet Register reset[1] Register Reset state Interrupt Enable Register all bits cleared Interrupt Identification Register bit 0 is set; all other bits cleared FIFO Control Register all bits cleared Line Control Register reset to 0001 1101 (0x1D) Modem Control Register all bits cleared Line Status Register bit 5 and bit 6 set; all other bits cleared Modem Status Register bits 0:3 cleared; bits 4:7 input signals Enhanced Feature Register all bits cleared Receiver Holding Register pointer logic cleared Transmitter Holding Register pointer logic cleared Transmission Control Register all bits cleared. Trigger Level Register all bits cleared. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 13 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 4. Register reset[1] Register Reset state Transmit FIFO level reset to 0100 0000 (0x40) Receive FIFO level all bits cleared I/O direction[2] all bits cleared I/O interrupt enable[2] all bits cleared I/O control[3] all bits cleared Extra Feature Register all bits cleared [1] Registers DLL, DLH, SPR, XON1, XON2, XOFF1, XOFF2 are not reset by the top-level reset signal RESET, POR or Software Reset, that is, they hold their initialization values during reset. [2] This register is not supported in SC16IS740. [3] Only UART Software Reset bit is supported in this register. Table 5 summarizes the state of registers after reset. Table 5. Output signals after reset Signal Reset state TX HIGH RTS HIGH I/Os inputs IRQ HIGH by external pull-up 7.4.2 Power-on sequence After power is applied, the device is reset by the internal POR. The host must wait at least 3 s before initializing a communication with the device. An external reset pulse (see Figure 26) can also be used to reset the device after power is applied. Once the device is reset properly, the host processor can start to communicate with the device. Internal registers can be accessed (read and write), however, at this time the UART transmitter and receiver cannot be used until there is a stable clock at XTAL1 pin. Normally, if an external clock such as a system clock or an external oscillator is used to supply a clock to XTAL1 pin, the clock should be stable at this time. But if a crystal is used, the host processor must wait until the crystal is generating a stable clock before accessing the UART transmitter or receiver. The crystal’s start-up time depends on the crystal being used, VCC ramp-up time and the loading capacitor values. The start-up time can be as long as a few milliseconds. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 14 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR voltage (V) oscillator starts stable clocks XTAL1 VIH 0V tstartup time (ms) 002aaf521 Fig 12. Start-up time 7.5 Interrupts The SC16IS740/750/760 has interrupt generation and prioritization (seven prioritized levels of interrupts) capability. The interrupt enable registers (IER and IOIntEna) enable each of the seven types of interrupts and the IRQ signal in response to an interrupt generation. When an interrupt is generated, the IIR indicates that an interrupt is pending and provides the type of interrupt through IIR[5:0]. Table 6 summarizes the interrupt control functions. Table 6. Summary of interrupt control functions IIR[5:0] Priority level Interrupt type 00 0001 none none none 00 0110 1 receiver line status OE, FE, PE, or BI errors occur in characters in the RX FIFO 00 1100 2 RX time-out Stale data in RX FIFO 00 0100 2 RHR interrupt Receive data ready (FIFO disable) or RX FIFO above trigger level (FIFO enable) 00 0010 3 THR interrupt Transmit FIFO empty (FIFO disable) or TX FIFO passes above trigger level (FIFO enable) 00 0000 4 modem status[1] Change of state of modem input pins 11 0000 5 I/O pins[1] Input pins change of state 01 0000 6 Xoff interrupt Receive Xoff character(s)/ special character 10 0000 7 CTS, RTS RTS pin or CTS pin change state from active (LOW) to inactive (HIGH) [1] Interrupt source Available only on SC16IS750/SC16IS760. It is important to note that for the framing error, parity error, and break conditions, LSR[7] generates the interrupt. LSR[7] is set when there is an error anywhere in the RX FIFO, and is cleared only when there are no more errors remaining in the FIFO. LSR[4:2] always represent the error status for the received character at the top of the RX FIFO. Reading the RX FIFO updates LSR[4:2] to the appropriate status for the new character at the top of the FIFO. If the RX FIFO is empty, then LSR[4:2] are all zeros. For the Xoff interrupt, if an Xoff flow character detection caused the interrupt, the interrupt is cleared by an Xon flow character detection. If a special character detection caused the interrupt, the interrupt is cleared by a read of the IIR. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 15 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 7.5.1 Interrupt mode operation In Interrupt mode (if any bit of IER[3:0] is 1) the host is informed of the status of the receiver and transmitter by an interrupt signal, IRQ. Therefore, it is not necessary to continuously poll the Line Status Register (LSR) to see if any interrupt needs to be serviced. Figure 13 shows Interrupt mode operation. IIR read IIR IRQ HOST IER 1 1 THR 1 1 RHR 002aab042 Fig 13. Interrupt mode operation 7.5.2 Polled mode operation In Polled mode (IER[3:0] = 0000) the status of the receiver and transmitter can be checked by polling the Line Status Register (LSR). This mode is an alternative to the FIFO Interrupt mode of operation where the status of the receiver and transmitter is automatically known by means of interrupts sent to the CPU. Figure 14 shows FIFO Polled mode operation. LSR read LSR HOST IER 0 THR 0 0 0 RHR 002aab043 Fig 14. FIFO Polled mode operation SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 16 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 7.6 Sleep mode Sleep mode is an enhanced feature of the SC16IS740/750/760 UART. It is enabled when EFR[4], the enhanced functions bit, is set and when IER[4] is set. Sleep mode is entered when: • The serial data input line, RX, is idle (see Section 7.7 “Break and time-out conditions”). • The TX FIFO and TX shift register are empty. • There are no interrupts pending except THR. Remark: Sleep mode will not be entered if there is data in the RX FIFO. In Sleep mode, the clock to the UART is stopped. Since most registers are clocked using these clocks, the power consumption is greatly reduced. The UART will wake up when any change is detected on the RX line, when there is any change in the state of the modem input pins, or if data is written to the TX FIFO. Wake-up by serial data on RX input pin is supported in UART mode but not in IrDA mode in Rev. C and Rev. D of the device. Refer to application note AN10964, “How to wake up SC16IS/740/750/760 in IrDA mode” for a software procedure to wake up the device by receiving data in the IrDA mode. Wake-up by serial data on RX input pin is supported in both UART mode and IrDA mode in Rev. E of the device. The device will not wake up by GPIO pin transition, but GPIO pin input state can be read, and GPIO interrupt is working normally during Sleep mode. Remark: Writing to the divisor latches, DLL and DLH, to set the baud clock, must not be done during Sleep mode. Therefore, it is advisable to disable Sleep mode using IER[4] before writing to DLL or DLH. 7.7 Break and time-out conditions When the UART receives a number of characters and these data are not enough to set off the receive interrupt (because they do not reach the receive trigger level), the UART will generate a time-out interrupt instead, 4 character times after the last character is received. The time-out counter will be reset at the center of each stop bit received or each time the receive FIFO is read. A break condition is detected when the RX pin is pulled LOW for a duration longer than the time it takes to send a complete character plus Start, Stop and Parity bits. A break condition can be sent by setting LCR[6]. When this happens the TX pin will be pulled LOW until LSR[6] is cleared by the software. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 17 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 7.8 Programmable baud rate generator The SC16IS740/750/760 UART contains a programmable baud rate generator that takes any clock input and divides it by a divisor in the range between 1 and (216 – 1). An additional divide-by-4 prescaler is also available and can be selected by MCR[7], as shown in Figure 15. The output frequency of the baud rate generator is 16  the baud rate. The formula for the divisor is given in Equation 1: XTAL1 crystal input frequency  ----------------------------------------------------------------------------------  prescaler divisor = ----------------------------------------------------------------------------------------desired baud rate  16 (1) where: prescaler = 1, when MCR[7] is set to ‘0’ after reset (divide-by-1 clock selected) prescaler = 4, when MCR[7] is set to ‘1’ after reset (divide-by-4 clock selected). Remark: The default value of prescaler after reset is divide-by-1. Figure 15 shows the internal prescaler and baud rate generator circuitry. PRESCALER LOGIC (DIVIDE-BY-1) XTAL1 XTAL2 INTERNAL OSCILLATOR LOGIC MCR[7] = 0 input clock PRESCALER LOGIC (DIVIDE-BY-4) reference clock BAUD RATE GENERATOR LOGIC internal baud rate clock for transmitter and receiver MCR[7] = 1 002aaa233 Fig 15. Prescaler and baud rate generator block diagram DLL and DLH must be written to in order to program the baud rate. DLL and DLH are the least significant and most significant byte of the baud rate divisor. If DLL and DLH are both zero, the UART is effectively disabled, as no baud clock will be generated. Remark: The programmable baud rate generator is provided to select both the transmit and receive clock rates. Table 7 and Table 8 show the baud rate and divisor correlation for crystal with frequency 1.8432 MHz and 3.072 MHz, respectively. The crystal’s frequency tolerance should be selected as such to keep the baud rate error to be below 1 % for reliable operation with other UARTs. Crystals with 100 ppm is generally recommended. Figure 16 shows the crystal clock circuit reference. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 18 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 7. Desired baud rate Divisor used to generate 16 clock Percent error difference between desired and actual 50 2304 0 75 1536 0 110 1047 0.026 134.5 857 0.058 150 768 0 300 384 0 600 192 0 1200 96 0 1800 64 0 2000 58 0.69 2400 48 0 3600 32 0 4800 24 0 7200 16 0 9600 12 0 19200 6 0 38400 3 0 56000 2 2.86 Table 8. SC16IS740_750_760 Product data sheet Baud rates using a 1.8432 MHz crystal Baud rates using a 3.072 MHz crystal Desired baud rate Divisor used to generate 16 clock Percent error difference between desired and actual 50 2304 0 75 2560 0 110 1745 0.026 134.5 1428 0.034 150 1280 0 300 640 0 600 320 0 1200 160 0 1800 107 0.312 2000 96 0 2400 80 0 3600 53 0.628 4800 40 0 7200 27 1.23 9600 20 0 19200 10 0 38400 5 0 All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 19 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR XTAL1 XTAL2 1.8432 MHz C1 22 pF C2 33 pF 002aab402 Fig 16. Crystal oscillator circuit reference 8. Register descriptions The programming combinations for register selection are shown in Table 9. Table 9. SC16IS740_750_760 Product data sheet Register map - read/write properties Register name Read mode Write mode RHR/THR Receive Holding Register (RHR) Transmit Holding Register (THR) IER Interrupt Enable Register (IER) Interrupt Enable Register IIR/FCR Interrupt Identification Register (IIR) FIFO Control Register (FCR) LCR Line Control Register (LCR) Line Control Register MCR Modem Control Register (MCR)[1] Modem Control Register[1] LSR Line Status Register (LSR) n/a MSR Modem Status Register (MSR) n/a SPR Scratchpad Register (SPR) Scratchpad Register TCR Transmission Control Register (TCR)[2] Transmission Control Register[2] (TLR)[2] Trigger Level Register[2] TLR Trigger Level Register TXLVL Transmit FIFO Level Register RXLVL Receive FIFO Level Register n/a IODir[3] I/O pin Direction Register I/O pin Direction Register IOState[3] I/O pin States Register n/a IOIntEna[3] I/O Interrupt Enable Register I/O Interrupt Enable Register IOControl[3] I/O pins Control Register I/O pins Control Register EFCR Extra Features Register Extra Features Register (DLL)[4] n/a divisor latch LSB[4] DLL divisor latch LSB DLH divisor latch MSB (DLH)[4] divisor latch MSB[4] EFR Enhanced Feature Register (EFR)[5] Enhanced Feature Register[5] XON1 Xon1 word[5] Xon1 word[5] XON2 Xon2 word[5] Xon2 word[5] XOFF1 Xoff1 word[5] Xoff1 word[5] XOFF2 Xoff2 word[5] Xoff2 word[5] [1] MCR[7] can only be modified when EFR[4] is set. [2] Accessible only when ERF[4] = 1 and MCR[2] = 1, that is, EFR[4] and MCR[2] are read/write enables. [3] Available only on SC16IS750/SC16IS760. [4] Accessible only when LCR[7] is logic 1. [5] Accessible only when LCR is set to 1011 1111b (0xBF). All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 20 of 63 xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx SC16IS740/750/760 internal registers Register address Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W bit 3 bit 2 bit 1 bit 0 R bit 3 bit 2 bit 1 bit 0 W modem status receive line THR empty interrupt status interrupt interrupt RX data available interrupt R/W W NXP Semiconductors SC16IS740_750_760 Product data sheet Table 10. General register set[1] 0x00 RHR bit 7 bit 6 bit 5 bit 4 0x00 THR bit 7 bit 6 bit 5 bit 4 CTS interrupt enable[2] RTS interrupt enable[2] 0x02 FCR RX trigger level (MSB) RX trigger level (LSB) TX trigger TX trigger level (MSB)[2] level (LSB)[2] reserved[3] TX FIFO reset[4] RX FIFO reset[4] FIFO enable 0x02 IIR[5] FIFO enable FIFO enable interrupt interrupt priority bit 4[2] priority bit 3[2] interrupt priority bit 2 interrupt priority bit 1 interrupt priority bit 0 interrupt status R 0x03 LCR Divisor Latch set break Enable set parity even parity parity enable stop bit word length bit 1 word length bit 0 R/W 0x04 MCR clock divisor[2] IrDA mode enable[2] Xon Any[2] loopback enable reserved[3] TCR and TLR enable[2] RTS DTR/(IO5)[6] R/W 0x05 LSR FIFO data error THR and TSR empty THR empty break interrupt framing error parity error overrun error data in receiver R 0x06 MSR CD/(IO6)[6] RI/(IO7)[6] DSR/ (IO4)[6] CTS CD/ (IO6)[6] RI/(IO7)[6] DSR/ (IO4)[6] CTS R 0x07 SPR bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x06 TCR[7] bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x07 TLR[7] bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x08 TXLVL bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R 0x09 RXLVL bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R 0x0A IODir[6] bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x0B IOState[6] bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x0C IOIntEna[6] bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x0D reserved[3] reserved[3] reserved[3] reserved[3] reserved[3] reserved[3] reserved[3] reserved[3] reserved[3] 0x0E IOControl[6] reserved[3] reserved[3] reserved[3] reserved[3] UART software reset[8] reserved[3] I/O[7:4] or RI, latch CD, DTR, DSR R/W 0x0F EFCR IrDA mode reserved[3] (slow/ fast)[9] auto RS-485 RTS output inversion auto RS-485 RTS direction control reserved[3] transmitter disable receiver disable R/W 9-bit mode enable SC16IS740/750/760 21 of 63 © NXP B.V. 2011. All rights reserved. IER Sleep mode[2] Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Rev. 7 — 9 June 2011 All information provided in this document is subject to legal disclaimers. 0x01 Xoff[2] xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx SC16IS740/750/760 internal registers …continued Register address Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NXP Semiconductors SC16IS740_750_760 Product data sheet Table 10. R/W Special register set[10] 0x00 DLL bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x01 DLH bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W Enhanced register set[11] EFR Auto CTS Auto RTS special character detect enable enhanced functions software flow control bit 3 software flow control bit 2 software flow control bit 1 software flow control bit 0 R/W 0x04 XON1 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x05 XON2 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x06 XOFF1 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W 0x07 XOFF2 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 R/W These registers are accessible only when LCR[7] = 0. [2] These bits in can only be modified if register bit EFR[4] is enabled. [3] These bits are reserved and should be set to 0. [4] After Receive FIFO or Transmit FIFO reset (through FCR[1:0]), the user must wait at least 2  Tclk of XTAL1 before reading or writing data to RHR and THR, respectively. [5] Burst reads on the serial interface (that is, reading multiple elements on the I2C-bus without a STOP or repeated START condition, or reading multiple elements on the SPI bus without de-asserting the CS pin), should not be performed on the IIR register. [6] Only available on the SC16IS750/SC16IS760. [7] These registers are accessible only when MCR[2] = 1 and EFR[4] = 1. [8] Device returns NACK on I2C-bus when this bit is written. [9] IrDA mode slow/fast for SC16IS760, slow only for SC16IS750. [10] The special register set is accessible only when LCR[7] = 1 and not 0xBF. [11] Enhanced Feature Registers are only accessible when LCR = 0xBF. 22 of 63 © NXP B.V. 2011. All rights reserved. SC16IS740/750/760 [1] Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Rev. 7 — 9 June 2011 All information provided in this document is subject to legal disclaimers. 0x02 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.1 Receive Holding Register (RHR) The receiver section consists of the Receiver Holding Register (RHR) and the Receiver Shift Register (RSR). The RHR is actually a 64-byte FIFO. The RSR receives serial data from the RX pin. The data is converted to parallel data and moved to the RHR. The receiver section is controlled by the Line Control Register. If the FIFO is disabled, location zero of the FIFO is used to store the characters. 8.2 Transmit Holding Register (THR) The transmitter section consists of the Transmit Holding Register (THR) and the Transmit Shift Register (TSR). The THR is actually a 64-byte FIFO. The THR receives data and shifts it into the TSR, where it is converted to serial data and moved out on the TX pin. If the FIFO is disabled, the FIFO is still used to store the byte. Characters are lost if overflow occurs. 8.3 FIFO Control Register (FCR) This is a write-only register that is used for enabling the FIFOs, clearing the FIFOs, setting transmitter and receiver trigger levels. Table 11 shows FIFO Control Register bit settings. Table 11. FIFO Control Register bits description Bit Symbol 7:6 FCR[7] (MSB), RX trigger. Sets the trigger level for the RX FIFO. FCR[6] (LSB) 00 = 8 characters Description 01 = 16 characters 10 = 56 characters 11 = 60 characters 5:4 FCR[5] (MSB), TX trigger. Sets the trigger level for the TX FIFO. FCR[4] (LSB) 00 = 8 spaces 01 = 16 spaces 10 = 32 spaces 11 = 56 spaces FCR[5:4] can only be modified and enabled when EFR[4] is set. This is because the transmit trigger level is regarded as an enhanced function. 3 FCR[3] reserved 2 FCR[2][1] reset TX FIFO logic 0 = no FIFO transmit reset (normal default condition) logic 1 = clears the contents of the transmit FIFO and resets the FIFO level logic (the Transmit Shift Register is not cleared or altered). This bit will return to a logic 0 after clearing the FIFO. 1 FCR[1][1] reset RX FIFO logic 0 = no FIFO receive reset (normal default condition) logic 1 = clears the contents of the receive FIFO and resets the FIFO level logic (the Receive Shift Register is not cleared or altered). This bit will return to a logic 0 after clearing the FIFO. 0 FCR[0] FIFO enable logic 0 = disable the transmit and receive FIFO (normal default condition) logic 1 = enable the transmit and receive FIFO SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 23 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR [1] FIFO reset requires at least two XTAL1 clocks, therefore, they cannot be reset without the presence of the XTAL1 clock. 8.4 Line Control Register (LCR) This register controls the data communication format. The word length, number of stop bits, and parity type are selected by writing the appropriate bits to the LCR. Table 12 shows the Line Control Register bit settings. Table 12. Line Control Register bits description Bit Symbol Description 7 LCR[7] divisor latch enable logic 0 = divisor latch disabled (normal default condition) logic 1 = divisor latch enabled 6 LCR[6] Break control bit. When enabled, the break control bit causes a break condition to be transmitted (the TX output is forced to a logic 0 state). This condition exists until disabled by setting LCR[6] to a logic 0. logic 0 = no TX break condition (normal default condition). logic 1 = forces the transmitter output (TX) to a logic 0 to alert the communication terminal to a line break condition 5 LCR[5] Set parity. LCR[5] selects the forced parity format (if LCR[3] = 1). logic 0 = parity is not forced (normal default condition). LCR[5] = logic 1 and LCR[4] = logic 0: parity bit is forced to a logical 1 for the transmit and receive data. LCR[5] = logic 1 and LCR[4] = logic 1: parity bit is forced to a logical 0 for the transmit and receive data. 4 LCR[4] parity type select logic 0 = odd parity is generated (if LCR[3] = 1) logic 1 = even parity is generated (if LCR[3] = 1) 3 LCR[3] parity enable logic 0 = no parity (normal default condition). logic 1 = a parity bit is generated during transmission and the receiver checks for received parity 2 LCR[2] Number of stop bits. Specifies the number of stop bits. 0 to 1 stop bit (word length = 5, 6, 7, 8) 1 to 1.5 stop bits (word length = 5) 1 = 2 stop bits (word length = 6, 7, 8) 1:0 SC16IS740_750_760 Product data sheet LCR[1:0] Word length bits 1, 0. These two bits specify the word length to be transmitted or received; see Table 15. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 24 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 13. LCR[5] LCR[4] LCR[3] Parity selection X X 0 no parity 0 0 1 odd parity 0 1 1 even parity 1 0 1 forced parity ‘1’ 1 1 1 forced parity ‘0’ Table 14. LCR[2] stop bit length LCR[2] Word length (bits) Stop bit length (bit times) 0 5, 6, 7, 8 1 1 5 112 1 6, 7, 8 2 Table 15. SC16IS740_750_760 Product data sheet LCR[5] parity selection LCR[1:0] word length LCR[1] LCR[0] Word length (bits) 0 0 5 0 1 6 1 0 7 1 1 8 All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 25 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.5 Line Status Register (LSR) Table 16 shows the Line Status Register bit settings. Table 16. Line Status Register bits description Bit Symbol Description 7 LSR[7] FIFO data error. logic 0 = no error (normal default condition) logic 1 = at least one parity error, framing error, or break indication is in the receiver FIFO. This bit is cleared when no more errors are present in the FIFO. 6 LSR[6] THR and TSR empty. This bit is the Transmit Empty indicator. logic 0 = transmitter hold and shift registers are not empty logic 1 = transmitter hold and shift registers are empty 5 LSR[5] THR empty. This bit is the Transmit Holding Register Empty indicator. logic 0 = transmit hold register is not empty logic 1 = transmit hold register is empty. The host can now load up to 64 characters of data into the THR if the TX FIFO is enabled. 4 LSR[4] break interrupt logic 0 = no break condition (normal default condition) logic 1 = a break condition occurred and associated character is 0x00, that is, RX was LOW for one character time frame 3 LSR[3] framing error logic 0 = no framing error in data being read from RX FIFO (normal default condition). logic 1 = framing error occurred in data being read from RX FIFO, that is, received data did not have a valid stop bit 2 LSR[2] parity error. logic 0 = no parity error (normal default condition) logic 1 = parity error in data being read from RX FIFO 1 LSR[1] overrun error logic 0 = no overrun error (normal default condition) logic 1 = overrun error has occurred 0 LSR[0] data in receiver logic 0 = no data in receive FIFO (normal default condition) logic 1 = at least one character in the RX FIFO When the LSR is read, LSR[4:2] reflect the error bits (BI, FE, PE) of the character at the top of the RX FIFO (next character to be read). Therefore, errors in a character are identified by reading the LSR and then reading the RHR. LSR[7] is set when there is an error anywhere in the RX FIFO, and is cleared only when there are no more errors remaining in the FIFO. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 26 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.6 Modem Control Register (MCR) The MCR controls the interface with the mode, data set, or peripheral device that is emulating the modem. Table 17 shows the Modem Control Register bit settings. Table 17. Modem Control Register bits description Bit Symbol Description 7 MCR[7][1] clock divisor logic 0 = divide-by-1 clock input logic 1 = divide-by-4 clock input 6 MCR[6][1] IrDA mode enable logic 0 = normal UART mode logic 1 = IrDA mode 5 MCR[5][1] Xon Any logic 0 = disable Xon Any function logic 1 = enable Xon Any function 4 MCR[4] enable loopback logic 0 = normal operating mode logic 1 = enable local Loopback mode (internal). In this mode the MCR[1:0] signals are looped back into MSR[4:5] and the TX output is looped back to the RX input internally. 3 MCR[3] reserved 2 MCR[2] TCR and TLR enable logic 0 = disable the TCR and TLR register. logic 1 = enable the TCR and TLR register. 1 MCR[1] RTS logic 0 = force RTS output to inactive (HIGH) logic 1 = force RTS output to active (LOW). In Loopback mode, controls MSR[4]. If Auto RTS is enabled, the RTS output is controlled by hardware flow control. 0 MCR[0] DTR[2]. If GPIO5 is selected as DTR modem pin through IOControl register bit 1, the state of DTR pin can be controlled as below. Writing to IOState bit 5 will not have any effect on this pin. logic 0 = Force DTR output to inactive (HIGH) logic 1 = Force DTR output to active (LOW) SC16IS740_750_760 Product data sheet [1] MCR[7:5] and MCR[2] can only be modified when EFR[4] is set, that is, EFR[4] is a write enable. [2] Only available on SC16IS750/SC16IS760. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 27 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.7 Modem Status Register (MSR) This 8-bit register provides information about the current state of the control lines from the modem, data set, or peripheral device to the host. It also indicates when a control input from the modem changes state. Table 18 shows Modem Status Register bit settings. Table 18. Modem Status Register bits description Bit Symbol Description 7 MSR[7] CD[1] (active HIGH, logical 1). If GPIO6 is selected as CD modem pin through IOControl register bit 1, the state of CD pin can be read from this bit. This bit is the complement of the CD input. Reading IOState bit 6 does not reflect the true state of CD pin. 6 MSR[6] RI[1] (active HIGH, logical 1). If GPIO7 is selected as RI modem pin through IOControl register bit 1, the state of RI pin can be read from this bit. This bit is the complement of the RI input. Reading IOState bit 6 does not reflect the true state of RI pin. 5 MSR[5] DSR[1] (active HIGH, logical 1). If GPIO4 is selected as DSR modem pin through IOControl register bit 1, the state of DSR pin can be read from this bit. This bit is the complement of the DSR input. Reading IOState bit 4 does not reflect the true state of DSR pin. 4 MSR[4] CTS (active HIGH, logical 1). This bit is the complement of the CTS input. 3 MSR[3] CD[1]. Indicates that CD input has changed state. Cleared on a read. 2 MSR[2] RI[1]. Indicates that RI input has changed state from LOW to HIGH. Cleared on a read. 1 MSR[1] DSR[1]. Indicates that DSR input has changed state. Cleared on a read. 0 MSR[0] CTS. Indicates that CTS input has changed state. Cleared on a read. [1] Only available on SC16IS750/SC16IS760. Remark: The primary inputs RI, CD, CTS, DSR are all active LOW. 8.8 Scratch Pad Register (SPR) This 8-bit register is used as a temporary data storage register. User’s program can write to or read from this register without any effect on the operation of the device. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 28 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.9 Interrupt Enable Register (IER) The Interrupt Enable Register (IER) enables each of the six types of interrupt, receiver error, RHR interrupt, THR interrupt, modem status, Xoff received, or CTS/RTS change of state from LOW to HIGH. The IRQ output signal is activated in response to interrupt generation. Table 19 shows the Interrupt Enable Register bit settings. Table 19. Interrupt Enable Register bits description Bit Symbol Description 7 IER[7][1] CTS interrupt enable logic 0 = disable the CTS interrupt (normal default condition) logic 1 = enable the CTS interrupt 6 IER[6][1] RTS interrupt enable logic 0 = disable the RTS interrupt (normal default condition) logic 1 = enable the RTS interrupt 5 IER[5][1] Xoff interrupt logic 0 = disable the Xoff interrupt (normal default condition) logic 1 = enable the Xoff interrupt 4 IER[4][1] Sleep mode logic 0 = disable Sleep mode (normal default condition) logic 1 = enable Sleep mode. See Section 7.6 “Sleep mode” for details. 3 IER[3] Modem Status Interrupt[2]. logic 0 = disable the modem status register interrupt (normal default condition) logic 1 = enable the modem status register interrupt Remark: See IOControl register bit 1 in Table 30 for the description of how to program the pins as modem pins. 2 IER[2] Receive Line Status interrupt logic 0 = disable the receiver line status interrupt (normal default condition) logic 1 = enable the receiver line status interrupt 1 IER[1] Transmit Holding Register interrupt. logic 0 = disable the THR interrupt (normal default condition) logic 1 = enable the THR interrupt 0 IER[0] Receive Holding Register interrupt. logic 0 = disable the RHR interrupt (normal default condition) logic 1 = enable the RHR interrupt SC16IS740_750_760 Product data sheet [1] IER[7:4] can only be modified if EFR[4] is set, that is, EFR[4] is a write enable. Re-enabling IER[1] will not cause a new interrupt if the THR is below the threshold. [2] Only available on the SC16IS750/SC16IS760. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 29 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.10 Interrupt Identification Register (IIR) The IIR is a read-only 8-bit register which provides the source of the interrupt in a prioritized manner. Table 20 shows Interrupt Identification Register bit settings. Table 20. Interrupt Identification Register bits description Bit Symbol Description 7:6 IIR[7:6] mirror the contents of FCR[0] 5:1 IIR[5:1] 5-bit encoded interrupt. See Table 21. 0 IIR[0] interrupt status logic 0 = an interrupt is pending logic 1 = no interrupt is pending SC16IS740_750_760 Product data sheet Table 21. Interrupt source Priority level IIR[5] IIR[4] IIR[3] IIR[2] IIR[1] IIR[0] Source of the interrupt 1 0 0 0 1 1 0 Receiver Line Status error 2 0 0 1 1 0 0 Receiver time-out interrupt 2 0 0 0 1 0 0 RHR interrupt 3 0 0 0 0 1 0 THR interrupt 4 0 0 0 0 0 0 modem interrupt[1][2] 5 1 1 0 0 0 0 input pin change of state[1][2] 6 0 1 0 0 0 0 received Xoff signal/ special character 7 1 0 0 0 0 0 CTS, RTS change of state from active (LOW) to inactive (HIGH) [1] Modem interrupt status must be read via MSR register and GPIO interrupt status must be read via IOState register. [2] Only available on SC16IS750/SC16IS760. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 30 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.11 Enhanced Features Register (EFR) This 8-bit register enables or disables the enhanced features of the UART. Table 22 shows the enhanced feature register bit settings. Table 22. Enhanced Features Register bits description Bit Symbol Description 7 EFR[7] CTS flow control enable logic 0 = CTS flow control is disabled (normal default condition) logic 1 = CTS flow control is enabled. Transmission will stop when a HIGH signal is detected on the CTS pin. 6 RTS flow control enable. EFR[6] logic 0 = RTS flow control is disabled (normal default condition) logic 1 = RTS flow control is enabled. The RTS pin goes HIGH when the receiver FIFO halt trigger level TCR[3:0] is reached, and goes LOW when the receiver FIFO resume transmission trigger level TCR[7:4] is reached. 5 EFR[5] Special character detect logic 0 = Special character detect disabled (normal default condition) logic 1 = Special character detect enabled. Received data is compared with Xoff2 data. If a match occurs, the received data is transferred to FIFO and IIR[4] is set to a logical 1 to indicate a special character has been detected. 4 EFR[4] Enhanced functions enable bit logic 0 = disables enhanced functions and writing to IER[7:4], FCR[5:4], MCR[7:5]. logic 1 = enables the enhanced function IER[7:4], FCR[5:4], and MCR[7:5] so that they can be modified. 3:0 EFR[3:0] Combinations of software flow control can be selected by programming these bits. See Table 3 “Software flow control options (EFR[3:0])”. 8.12 Division registers (DLL, DLH) These are two 8-bit registers which store the 16-bit divisor for generation of the baud clock in the baud rate generator. DLH stores the most significant part of the divisor. DLL stores the least significant part of the divisor. Remark: DLL and DLH can only be written to before Sleep mode is enabled, that is, before IER[4] is set. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 31 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.13 Transmission Control Register (TCR) This 8-bit register is used to store the RX FIFO threshold levels to stop/start transmission during hardware/software flow control. Table 23 shows Transmission Control Register bit settings. Table 23. Transmission Control Register bits description Bit Symbol Description 7:4 TCR[7:4] RX FIFO trigger level to resume 3:0 TCR[3:0] RX FIFO trigger level to halt transmission TCR trigger levels are available from 0 to 60 characters with a granularity of four. Remark: TCR can only be written to when EFR[4] = 1 and MCR[2] = 1. The programmer must program the TCR such that TCR[3:0] > TCR[7:4]. There is no built-in hardware check to make sure this condition is met. Also, the TCR must be programmed with this condition before auto RTS or software flow control is enabled to avoid spurious operation of the device. 8.14 Trigger Level Register (TLR) This 8-bit register is used to store the transmit and received FIFO trigger levels used for interrupt generation. Trigger levels from 4 to 60 can be programmed with a granularity of 4. Table 24 shows trigger level register bit settings. Table 24. Trigger Level Register bits description Bit Symbol Description 7:4 TLR[7:4] RX FIFO trigger levels (4 to 60), number of characters available. 3:0 TLR[3:0] TX FIFO trigger levels (4 to 60), number of spaces available. Remark: TLR can only be written to when EFR[4] = 1 and MCR[2] = 1. If TLR[3:0] or TLR[7:4] are logical 0, the selectable trigger levels via the FIFO Control Register (FCR) are used for the transmit and receive FIFO trigger levels. Trigger levels from 4 characters to 60 characters are available with a granularity of four. The TLR should be programmed for N4, where N is the desired trigger level. When the trigger level setting in TLR is zero, the SC16IS740/750/760 uses the trigger level setting defined in FCR. If TLR has non-zero trigger level value, the trigger level defined in FCR is discarded. This applies to both transmit FIFO and receive FIFO trigger level setting. When TLR is used for RX trigger level control, FCR[7:6] should be left at the default state, that is, ‘00’. 8.15 Transmitter FIFO Level register (TXLVL) This register is a read-only register, it reports the number of spaces available in the transmit FIFO. SC16IS740_750_760 Product data sheet Table 25. Transmitter FIFO Level register bits description Bit Symbol Description 7 - not used; set to zeros 6:0 TXLVL[6:0] number of spaces available in TX FIFO, from 0 (0x00) to 64 (0x40) All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 32 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.16 Receiver FIFO Level register (RXLVL) This register is a read-only register, it reports the fill level of the receive FIFO. That is, the number of characters in the RX FIFO. Table 26. Receiver FIFO Level register bits description Bit Symbol Description 7 - not used; set to zeros 6:0 RXLVL[6:0] number of characters stored in RX FIFO, from 0 (0x00) to 64 (0x40) 8.17 Programmable I/O pins Direction register (IODir) This register is only available on the SC16IS750 and SC16IS760. This register is used to program the I/O pins direction. Bit 0 to bit 7 controls GPIO0 to GPIO7. Table 27. IODir register bits description Bit Symbol Description 7:0 IODir set GPIO pins [7:0] to input or output 0 = input 1 = output Remark: If there is a pending input (GPIO) interrupt and IODir is written, this pending interrupt will be cleared, that is, the interrupt signal will be negated. 8.18 Programmable I/O pins State Register (IOState) This register is only available on the SC16IS750 and SC16IS760. When ‘read’, this register returns the actual state of all I/O pins. When ‘write’, each register bit will be transferred to the corresponding IO pin programmed as output. Table 28. IOState register bits description Bit Symbol Description 7:0 IOState Write this register: set the logic level on the output pins 0 = set output pin to zero 1 = set output pin to one Read this register: return states of all pins 8.19 I/O Interrupt Enable Register (IOIntEna) This register is only available on the SC16IS750 and SC16IS760. This register enables the interrupt due to a change in the I/O configured as inputs. If GPIO[7:4] are programmed as modem pins, their interrupt generation must be enabled via IER register bit 3. In this case bit 7 to bit 4 of IOIntEna will have no effect on GPIO[7:4]. Table 29. IOIntEna register bits description Bit Symbol Description 7:0 IOIntEna input interrupt enable 0 = a change in the input pin will not generate an interrupt 1 = a change in the input will generate an interrupt SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 33 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.20 I/O Control register (IOControl) This register is only available on the SC16IS750 and SC16IS760. Table 30. IOControl register bits description Bit Symbol Description 7:4 - reserved for future use 3 SRESET software reset A write to bit will reset the device. Once the device is reset this bit is automatically set to ‘0’ 2 - reserved for future use 1 GPIO[7:4] or modem pins This bit programs GPIO[7:4] as I/O pins or modem RI, CD, DTR, DSR pins. 0 = GPIO[7:4] behave as I/O pins 1 = GPIO[7:4] behave as RI, CD, DTR, DSR 0 IOLATCH enable/disable inputs latching 0 = input values are not latched. A change in any input generates an interrupt. A read of the input register clears the interrupt. If the input goes back to its initial logic state before the input register is read, then the interrupt is cleared. 1 = input values are latched. A change in the input generates an interrupt and the input logic value is loaded in the bit of the corresponding input state register (IOState). A read of the IOState register clears the interrupt. If the input pin goes back to its initial logic state before the interrupt register is read, then the interrupt is not cleared and the corresponding bit of the IOState register keeps the logic value that initiates the interrupt. Remark: As I/O pins, the direction, state, and interrupt of GPIO4 to GPIO7 are controlled by the following registers: IODir, IOState, IOIntEna, and IOControl. The state of CD, RI, DSR pins will not be reflected in MSR[7:5] or MSR[3:1], and any change of state on these three pins will not trigger a modem status interrupt (even if enabled via IER[3]), and the state of the DTR pin cannot be controlled by MCR[0]. As modem CD, RI, DSR pins, the status at the input of these three pins can be read from MSR[7:5] and MSR[3:1], and the state of DTR pin can be controlled by MCR[0]. Also, if modem status interrupt bit is enabled, IER[3], a change of state of RI, CD, DSR pins will trigger a modem interrupt. Bit[7:4] of the IODir, IOState, and IOIntEna registers will not have any effect on these three pins. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 34 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 8.21 Extra Features Control Register (EFCR) Table 31. Extra Features Control Register bits description Bit Symbol Description 7 IRDA MODE IrDA mode 0 = IrDA SIR, 316 pulse ratio, data rate up to 115.2 kbit/s 1 = IrDA SIR, 14 pulse ratio, data rate up to 1.152 Mbit/s[1] 6 - reserved 5 RTSINVER invert RTS signal in RS-485 mode 0: RTS = 0 during transmission and RTS = 1 during reception 1: RTS = 1 during transmission and RTS = 0 during reception 4 RTSCON enable the transmitter to control the RTS pin 0 = transmitter does not control RTS pin 1 = transmitter controls RTS pin 3 - reserved 2 TXDISABLE Disable transmitter. UART does not send serial data out on the transmit pin, but the transmit FIFO will continue to receive data from host until full. Any data in the TSR will be sent out before the transmitter goes into disable state. 0: transmitter is enabled 1: transmitter is disabled 1 RXDISABLE Disable receiver. UART will stop receiving data immediately once this bit set to a 1, and any data in the TSR will be sent to the receive FIFO. User is advised not to set this bit during receiving. 0: receiver is enabled 1: receiver is disabled 0 9-BIT MODE Enable 9-bit or Multidrop mode (RS-485). 0: normal RS-232 mode 1: enables RS-485 mode [1] For SC16IS760 only. 9. RS-485 features 9.1 Auto RS-485 RTS control Normally the RTS pin is controlled by MCR bit 1, or if hardware flow control is enabled, the logic state of the RTS pin is controlled by the hardware flow control circuitry. EFCR register bit 4 will take the precedence over the other two modes; once this bit is set, the transmitter will control the state of the RTS pin. The transmitter automatically asserts the RTS pin (logic 0) once the host writes data to the transmit FIFO, and deasserts RTS pin (logic 1) once the last bit of the data has been transmitted. To use the auto RS-485 RTS mode the software would have to disable the hardware flow control function. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 35 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 9.2 RS-485 RTS output inversion EFCR bit 5 reverses the polarity of the RTS pin if the UART is in auto RS-485 RTS mode. When the transmitter has data to be sent it will deasserts the RTS pin (logic 1), and when the last bit of the data has been sent out the transmitter asserts the RTS pin (logic 0). 9.3 Auto RS-485 EFCR bit 0 is used to enable the RS-485 mode (multidrop or 9-bit mode). In this mode of operation, a ‘master’ station transmits an address character followed by data characters for the addressed ‘slave’ stations. The slave stations examine the received data and interrupt the controller if the received character is an address character (parity bit = 1). To use the auto RS-485 mode the software would have to disable the hardware and software flow control functions. 9.3.1 Normal multidrop mode The 9-bit Mode in EFCR (bit 0) is enabled, but not Special Character Detect (EFR bit 5). The receiver is set to Force Parity 0 (LCR[5:3] = 111) in order to detect address bytes. With the receiver initially disabled, it ignores all the data bytes (parity bit = 0) until an address byte is received (parity bit = 1). This address byte will cause the UART to set the parity error. The UART will generate a line status interrupt (IER bit 2 must be set to ‘1’ at this time), and at the same time puts this address byte in the RX FIFO. After the controller examines the byte it must make a decision whether or not to enable the receiver; it should enable the receiver if the address byte addresses its ID address, and must not enable the receiver if the address byte does not address its ID address. If the controller enables the receiver, the receiver will receive the subsequent data until being disabled by the controller after the controller has received a complete message from the ‘master’ station. If the controller does not disable the receiver after receiving a message from the ‘master’ station, the receiver will generate a parity error upon receiving another address byte. The controller then determines if the address byte addresses its ID address, if it is not, the controller then can disable the receiver. If the address byte addresses the ‘slave’ ID address, the controller take no further action, the receiver will receive the subsequent data. 9.3.2 Auto address detection If Special Character Detect is enabled (EFR[5] is set and the XOFF2 register contains the address byte) the receiver will try to detect an address byte that matches the programmed character in the XOFF2 register. If the received byte is a data byte or an address byte that does not match the programmed character in the XOFF2 register, the receiver will discard these data. Upon receiving an address byte that matches the Xoff2 character, the receiver will be automatically enabled if not already enabled, and the address character is pushed into the RX FIFO along with the parity bit (in place of the parity error bit). The receiver also generates a line status interrupt (IER[2] must be set to ‘1’ at this time). The receiver will then receive the subsequent data from the ‘master’ station until being disabled by the controller after having received a message from the ‘master’ station. If another address byte is received and this address byte does not match Xoff2 character, the receiver will be automatically disabled and the address byte is ignored. If the address byte matches Xoff2 character, the receiver will put this byte in the RX FIFO along with the parity bit in the parity error bit (LSR bit 2). SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 36 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 10. I2C-bus operation The two lines of the I2C-bus are a serial data line (SDA) and a serial clock line (SCL). Both lines are connected to a positive supply via a pull-up resistor, and remain HIGH when the bus is not busy. Each device is recognized by a unique address whether it is a microcomputer, LCD driver, memory or keyboard interface and can operate as either a transmitter or receiver, depending on the function of the device. A device generating a message or data is a transmitter, and a device receiving the message or data is a receiver. Obviously, a passive function like an LCD driver could only be a receiver, while a microcontroller or a memory can both transmit and receive data. 10.1 Data transfers One data bit is transferred during each clock pulse (see Figure 17). The data on the SDA line must remain stable during the HIGH period of the clock pulse in order to be valid. Changes in the data line at this time will be interpreted as control signals. A HIGH-to-LOW transition of the data line (SDA) while the clock signal (SCL) is HIGH indicates a START condition, and a LOW-to-HIGH transition of the SDA while SCL is HIGH defines a STOP condition (see Figure 18). The bus is considered to be busy after the START condition and free again at a certain time interval after the STOP condition. The START and STOP conditions are always generated by the master. SDA SCL data line stable; data valid change of data allowed mba607 Fig 17. Bit transfer on the I2C-bus SDA SCL S P START condition STOP condition mba608 Fig 18. START and STOP conditions The number of data bytes transferred between the START and STOP condition from transmitter to receiver is not limited. Each byte, which must be eight bits long, is transferred serially with the most significant bit first, and is followed by an acknowledge bit (see Figure 19). The clock pulse related to the acknowledge bit is generated by the master. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse, while the transmitting device releases this pulse (see Figure 20). SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 37 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR acknowledgement signal from receiver SDA MSB SCL 0 S 1 6 7 8 0 1 2 to 7 ACK START condition 8 P ACK byte complete, interrupt within receiver STOP condition clock line held LOW while interrupt is serviced 002aab012 Fig 19. Data transfer on the I2C-bus data output by transmitter transmitter stays off of the bus during the acknowledge clock data output by receiver SCL from master acknowledgement signal from receiver S 0 1 6 7 8 002aab013 START condition Fig 20. Acknowledge on the I2C-bus A slave receiver must generate an acknowledge after the reception of each byte, and a master must generate one after the reception of each byte clocked out of the slave transmitter. There are two exceptions to the ‘acknowledge after every byte’ rule. The first occurs when a master is a receiver: it must signal an end of data to the transmitter by not signalling an acknowledge on the last byte that has been clocked out of the slave. The acknowledge related clock, generated by the master should still take place, but the SDA line will not be pulled down. In order to indicate that this is an active and intentional lack of acknowledgement, we shall term this special condition as a ‘negative acknowledge’. The second exception is that a slave will send a negative acknowledge when it can no longer accept additional data bytes. This occurs after an attempted transfer that cannot be accepted. 10.2 Addressing and transfer formats Each device on the bus has its own unique address. Before any data is transmitted on the bus, the master transmits on the bus the address of the slave to be accessed for this transaction. A well-behaved slave with a matching address, if it exists on the network, should of course acknowledge the master's addressing. The addressing is done by the first byte transmitted by the master after the START condition. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 38 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR An address on the network is seven bits long, appearing as the most significant bits of the address byte. The last bit is a direction (R/W) bit. A ‘0’ indicates that the master is transmitting (write) and a ‘1’ indicates that the master requests data (read). A complete data transfer, comprised of an address byte indicating a ‘write’ and two data bytes is shown in Figure 21. SDA SCL S START condition 0 to 6 address 7 R/W 8 ACK 0 to 6 data 7 8 ACK 0 to 6 data 7 8 P ACK STOP condition 002aab046 Fig 21. A complete data transfer When an address is sent, each device in the system compares the first seven bits after the START with its own address. If there is a match, the device will consider itself addressed by the master, and will send an acknowledge. The device could also determine if in this transaction it is assigned the role of a slave receiver or slave transmitter, depending on the R/W bit. Each node of the I2C-bus network has a unique seven-bit address. The address of a microcontroller is of course fully programmable, while peripheral devices usually have fixed and programmable address portions. When the master is communicating with one device only, data transfers follow the format of Figure 21, where the R/W bit could indicate either direction. After completing the transfer and issuing a STOP condition, if a master would like to address some other device on the network, it could start another transaction by issuing a new START. Another way for a master to communicate with several different devices would be by using a ‘repeated START’. After the last byte of the transaction was transferred, including its acknowledge (or negative acknowledge), the master issues another START, followed by address byte and data — without effecting a STOP. The master may communicate with a number of different devices, combining ‘reads’ and ‘writes’. After the last transfer takes place, the master issues a STOP and releases the bus. Possible data formats are demonstrated in Figure 22. Note that the repeated START allows for both change of a slave and a change of direction, without releasing the bus. We shall see later on that the change of direction feature can come in handy even when dealing with a single device. In a single master system, the repeated START mechanism may be more efficient than terminating each transfer with a STOP and starting again. In a multimaster environment, the determination of which format is more efficient could be more complicated, as when a master is using repeated STARTs it occupies the bus for a long time and thus preventing other devices from initiating transfers. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 39 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR data transferred (n bytes + acknowledge) master write: S SLAVE ADDRESS START condition W write A DATA acknowledge A DATA acknowledge A P acknowledge STOP condition data transferred (n bytes + acknowledge) master read: S SLAVE ADDRESS START condition R read A DATA acknowledge A DATA acknowledge NA P not acknowledge STOP condition data transferred (n bytes + acknowledge) combined formats: S SLAVE ADDRESS R/W START condition read or write A DATA acknowledge A acknowledge data transferred (n bytes + acknowledge) Sr SLAVE ADDRESS R/W repeated START condition read or write A DATA acknowledge direction of transfer may change at this point A P acknowledge STOP condition 002aab458 Fig 22. I2C-bus data formats SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 40 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 10.3 Addressing Before any data is transmitted or received, the master must send the address of the receiver via the SDA line. The first byte after the START condition carries the address of the slave device and the read/write bit. Table 32 shows how the SC16IS740/750/760’s address can be selected by using A1 and A0 pins. For example, if these 2 pins are connected to VDD, then the SC16IS740/750/760’s address is set to 0x90, and the master communicates with it through this address. Table 32. SC16IS740/750/760 address map A1 A0 SC16IS750/760 I2C addresses (hex)[1] VDD VDD 0x90 (1001 000X) VDD VSS 0x92 (1001 001X) VDD SCL 0x94 (1001 010X) VDD SDA 0x96 (1001 011X) VSS VDD 0x98 (1001 100X) VSS VSS 0x9A (1001 101X) VSS SCL 0x9C (1001 110X) VSS SDA 0x9E (1001 111X) SCL VDD 0xA0 (1010 000X) SCL VSS 0xA2 (1010 001X) SCL SCL 0xA4 (1010 010X) SCL SDA 0xA6 (1010 011X) SDA VDD 0xA8 (1010 100X) SDA VSS 0xAA (1010 101X) SDA SCL 0xAC (1010 110X) SDA SDA 0xAE (1010 111X) [1] X = logic 0 for write cycle; X = logic 1 for read cycle. 10.4 Use of subaddresses When a master communicates with the SC16IS740/750/760 it must send a subaddress in the byte following the slave address byte. This subaddress is the internal address of the word the master wants to access for a single byte transfer, or the beginning of a sequence of locations for a multi-byte transfer. A subaddress is an 8-bit byte. Unlike the device address, it does not contain a direction (R/W) bit, and like any byte transferred on the bus it must be followed by an acknowledge. Table 33 shows the breakdown of the subaddress (register address) byte. Bit 0 is not used, bits [2:1] are both set to zeroes, bits [6:3] are used to select one of the device’s internal registers, and bit 7 is not used. A register write cycle is shown in Figure 23. The START is followed by a slave address byte with the direction bit set to ‘write’, a subaddress byte, a number of data bytes, and a STOP signal. The subaddress indicates which register the master wants to access, and the data bytes which follow will be written one after the other to the subaddress location. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 41 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 33 and Table 34 show the bits’ presentation at the subaddress byte for I2C-bus and SPI interfaces. Bit 0 is not used, bits 2:1 select the channel, bits 6:3 select one of the UART internal registers. Bit 7 is not used with the I2C-bus interface, but it is used by the SPI interface to indicate a read or a write operation. S SLAVE ADDRESS W A REGISTER ADDRESS(1) A nDATA A P 002aab047 White block: host to SC16IS740/750/760 Grey block: SC16IS740/750/760 to host (1) See Table 33 for additional information. Fig 23. Master writes to slave The register read cycle (see Figure 24) commences in a similar manner, with the master sending a slave address with the direction bit set to ‘write’ with a following subaddress. Then, in order to reverse the direction of the transfer, the master issues a repeated START followed again by the device address, but this time with the direction bit set to ‘read’. The data bytes starting at the internal subaddress will be clocked out of the device, each followed by a master-generated acknowledge. The last byte of the read cycle will be followed by a negative acknowledge, signalling the end of transfer. The cycle is terminated by a STOP signal. S SLAVE ADDRESS W REGISTER ADDRESS(1) A A S nDATA SLAVE ADDRESS A LAST DATA R A NA P 002aab048 White block: host to SC16IS740/750/760 Grey block: SC16IS740/750/760 to host (1) See Table 33 for additional information. Fig 24. Master read from slave Table 33. Register address byte (I2C) Bit Name Function 7 - not used 6:3 A[3:0] UART’s internal register select 2:1 CH1, CH0 channel select: CH1 = 0, CH0 = 0 Other values are reserved and should not be used. 0 SC16IS740_750_760 Product data sheet - not used All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 42 of 63 xxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx x xxxxxxxxxxxxxx xxxxxxxxxx xxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxx xx xxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxx xxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxx xxxxxx xx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxx xxxxx x x R/W A3 A2 A1 A0 CH1 CH0 X D7 D6 D5 D4 D3 D2 D1 D0 D6 D5 D4 D3 D2 D1 D0 D6 D5 D4 D3 D2 D1 D0 002aab433 R/W = 0; A[3:0] = register address; CH1 = 0, CH0 = 0 a. Register write SCLK SI R/W A3 A2 A1 A0 CH1 CH0 NXP Semiconductors SI 11. SPI operation SC16IS740_750_760 Product data sheet SCLK X D7 SO 002aab434 b. Register read SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 D7 D6 D5 D4 D3 D2 D1 D0 002aab435 last bit(2) 002aab436 R/W = 0; A[3:0] = 0000; CH1 = 0, CH0 = 0 c. FIFO write cycle SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 SO D6 D5 43 of 63 © NXP B.V. 2011. All rights reserved. R/W = 1; A[3:0] = 0000; CH1 = 0, CH0 = 0 d. FIFO read cycle (1) Last bit (D0) of the last byte to be written to the transmit FIFO. (2) Last bit (D0) of the last byte to be read from the receive FIFO. Fig 25. SPI operation D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 SC16IS740/750/760 last bit(1) Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Rev. 7 — 9 June 2011 All information provided in this document is subject to legal disclaimers. R/W = 1; A[3:0] = register address; CH1 = 0, CH0 = 0 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 34. Register address byte (SPI) Bit Name Function 7 R/W 1: read from UART 0: write to UART 6:3 A[3:0] UART’s internal register select 2:1 CH1, CH0 channel select: CH1 = 0, CH0 = 0 Other values are reserved and should not be used. 0 - not used 12. Limiting values Table 35. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Symbol Parameter VDD Conditions Min Max Unit supply voltage 0.3 +4.6 V V VI input voltage any input 0.3 +5.5[1] II input current any input 10 +10 mA IO output current any output 10 +10 mA Ptot total power dissipation - 300 mW P/out power dissipation per output - 50 mW Tamb ambient temperature 40 +85 C operating VDD = 2.5 V  0.2 V 40 +95 C Tj junction temperature VDD = 3.3 V  0.3 V - +125 C Tstg storage temperature 65 +150 C [1] SC16IS740_750_760 Product data sheet 5.5 V steady state voltage tolerance on inputs and outputs is valid only when the supply voltage is present. 4.6 V steady state voltage tolerance on inputs and outputs when no supply voltage is present. All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 44 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 13. Static characteristics Table 36. Static characteristics VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C; unless otherwise specified. Symbol Parameter Conditions VDD = 2.5 V VDD = 3.3 V Unit Min Max Min Max 2.3 2.7 3.0 3.6 V - 6.0 - 6.0 mA Supplies VDD supply voltage IDD supply current operating; no load Inputs I2C/SPI, RX, CTS VIH HIGH-level input voltage 1.6 5.5[1] 2.0 5.5[1] V VIL LOW-level input voltage - 0.6 - 0.8 V IL leakage current - 1 - 1 A Ci input capacitance - 3 - 3 pF 1.85 - - - V IOH = 4 mA - - 2.4 - V IOL = 1.6 mA - 0.4 - - V input; VI = 0 V or 5.5 V[1] Outputs TX, RTS, SO VOH HIGH-level output voltage VOL LOW-level output voltage Co output capacitance IOH = 400 A IOL = 4 mA - - - 0.4 V - 4 - 4 pF 1.6 5.5[1] 2.0 5.5[1] V Inputs/outputs GPIO0 to GPIO7 (SC16IS750 and SC16IS760 only) VIH HIGH-level input voltage VIL LOW-level input voltage VOH HIGH-level output voltage - 0.6 - 0.8 V 1.85 - - - V IOH = 4 mA - - 2.4 - V 0.4 - - V IOH = 400 A VOL LOW-level output voltage IOL = 1.6 mA - IOL = 4 mA - - - 0.4 V IL leakage current input; VI = 0 V or 5.5 V[1] - 1 - 1 A Co output capacitance - 4 - 4 pF RPU pull-up resistance 3.94 4.91 3.02 3.63 M IOL = 1.6 mA - 0.4 - - V IOL = 4 mA - - - 0.4 V - 4 - 4 pF active pull-up resistor Output IRQ VOL Co I2C-bus LOW-level output voltage output capacitance input/output SDA VIH HIGH-level input voltage 1.6 5.5[1] 2.0 5.5[1] V VIL LOW-level input voltage - 0.6 - 0.8 V VOL LOW-level output voltage IOL = 1.6 mA - 0.4 - - V IOL = 4 mA - - - 0.4 V IL leakage current input; VI = 0 V or 5.5 V[1] - 10 - 10 A Co output capacitance - 7 - 7 pF SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 45 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 36. Static characteristics …continued VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C; unless otherwise specified. Symbol I2C-bus Parameter Conditions VDD = 2.5 V VDD = 3.3 V Min Max Min Max Unit inputs SCL, CS/A0, SI/A1 VIH HIGH-level input voltage 1.6 5.5[1] 2.0 5.5[1] V VIL LOW-level input voltage - 0.6 - 0.8 V IL leakage current - 10 - 10 A Ci input capacitance - 7 - 7 pF 1.8 5.5[1] 2.4 5.5[1] V - 0.45 - 0.6 V 30 +30 30 +30 A - 3 - 3 pF - 30 - 30 A Clock input input; VI = 0 V or 5.5 V[1] XTAL1[2] VIH HIGH-level input voltage VIL LOW-level input voltage IL leakage current Ci input capacitance input; VI = 0 V or 5.5 V[1] Sleep current IDD(sleep) sleep mode supply current inputs are at VDD or ground [1] 5.5 V steady state voltage tolerance on inputs and outputs is valid only when the supply voltage is present. 3.8 V steady state voltage tolerance on inputs and outputs when no supply voltage is present. [2] XTAL2 should be left open when XTAL1 is driven by an external clock. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 46 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 14. Dynamic characteristics Table 37. I2C-bus timing specifications[1] All the timing limits are valid within the operating supply voltage, ambient temperature range and output load; VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C; and refer to VIL and VIH with an input voltage of VSS to VDD. All output load = 25 pF, except SDA output load = 400 pF. Symbol Parameter Conditions Standard mode I2C-bus Fast mode I2C-bus Min Max Min Max 0 100 0 400 [2] Unit fSCL SCL clock frequency tBUF bus free time between a STOP and START condition 4.7 - 1.3 - s tHD;STA hold time (repeated) START condition 4.0 - 0.6 - s tSU;STA set-up time for a repeated START condition 4.7 - 0.6 - s tSU;STO set-up time for STOP condition 4.7 - 0.6 - s tHD;DAT data hold time 0 - 0 - ns tVD;ACK data valid acknowledge time - 0.6 - 0.6 s tVD;DAT data valid time - 0.6 - 0.6 ns tSU;DAT data set-up time 250 - 150 - ns tLOW LOW period of the SCL clock 4.7 - 1.3 - s SCL LOW to data out valid kHz tHIGH HIGH period of the SCL clock 4.0 - 0.6 - s tf fall time of both SDA and SCL signals - 300 - 300 ns tr rise time of both SDA and SCL signals - 1000 - 300 ns tSP pulse width of spikes that must be suppressed by the input filter - 50 - 50 ns td1 I2C-bus GPIO output valid time 0.5 - 0.5 - s td2 I2C-bus modem input interrupt valid time 0.2 - 0.2 - s td3 I2C-bus modem input interrupt clear time 0.2 - 0.2 - s td4 I2C input pin interrupt valid time 0.2 - 0.2 - s td5 I2C input pin interrupt clear time 0.2 - 0.2 - s td6 I2C-bus receive interrupt valid time 0.2 - 0.2 - s td7 I2C-bus receive interrupt clear time 0.2 - 0.2 - s td8 I2C-bus transmit interrupt clear time 1.0 - 0.5 - s td15 SCL delay time after reset 3 - 3 - s tw(rst) reset pulse width 3 - 3 - s [3] [4] [1] A detailed description of the I2C-bus specification, with applications, is given in user manual UM10204: “I2C-bus specification and user manual”. This may be found at www.nxp.com/documents/user_manual/UM10204.pdf. [2] Minimum SCL clock frequency is limited by the bus time-out feature, which resets the serial bus interface if SDA is held LOW for a minimum of 25 ms. [3] Only applicable to the SC16IS750 and SC16IS760. [4] 2 XTAL1 clocks or 3 s, whichever is less. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 47 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR RESET tw(rst) td15 SCL 002aab437 Fig 26. SCL delay after reset protocol bit 7 MSB (A7) START condition (S) tSU;STA tLOW bit 0 LSB (R/W) bit 6 (A6) tHIGH 1/f acknowledge (A) STOP condition (P) SCL SCL tBUF tf tr tSP SDA tSU;DAT tHD;STA tVD;ACK tVD;DAT tHD;DAT tSU;STO 002aab489 Rise and fall times refer to VIL and VIH. Fig 27. I2C-bus timing diagram SDA SLAVE ADDRESS W A A IOSTATE REG. A A DATA td1 GPIOn 002aab255 Fig 28. Write to output (SC16IS750 and SC16IS760 only) ACK to master SDA SLAVE ADDRESS W A AMSR REGISTER A S SLAVE ADDRESS R A DATA A IRQ td2 td3 MODEM pin 002aab256 Fig 29. Modem input pin interrupt (SC16IS750 and SC16IS760 only) SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 48 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR ACK from slave SLAVE ADDRESS SDA W A A IOSTATE REG. ACK from slave A S SLAVE ADDRESS R ACK from master A A DATA P IRQ td4 td5 GPIOn 002aab257 Fig 30. GPIO pin interrupt (SC16IS750 and SC16IS760 only) RX next start bit stop bit start bit D0 D1 D2 D3 D4 D5 D6 D7 td6 IRQ 002aab258 Fig 31. Receive interrupt SDA SLAVE ADDRESS W A A A RHR S R SLAVE ADDRESS A A DATA P IRQ td7 002aab259 Fig 32. Receive interrupt clear SDA SLAVE ADDRESS W A ATHR REGISTER A A DATA IRQ td8 002aab260 Fig 33. Transmit interrupt clear SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 49 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 38. fXTAL dynamic characteristics VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C Symbol Parameter tw1 clock pulse duration tw2 clock pulse duration Conditions [1][2] frequency on pin XTAL fXTAL VDD = 2.5 V [1] Applies to external clock, crystal oscillator max. 24 MHz. [2] 1 f XTAL = ------t w3 [3] 100 ppm is recommended. tw2 VDD = 3.3 V Unit Min Max Min Max 10 - 6 - ns 10 - 6 - ns - 48[3] - 80 MHz tw1 EXTERNAL CLOCK 002aaa112 tw3 Fig 34. External clock timing Table 39. SC16IS740/750 SPI-bus timing specifications All the timing limits are valid within the operating supply voltage, ambient temperature range and output load; VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C; and refer to VIL and VIH with an input voltage of VSS to VDD. All output load = 25 pF, unless otherwise specified. Symbol Parameter Conditions Min Typ Max Unit tTR CS HIGH to SO 3-state delay time CL = 100 pF - - 100 ns tCSS CS to SCLK setup time 100 - - ns tCSH CS to SCLK hold time 20 - - ns tDO SCLK fall to SO valid delay time - - 100 ns tDS SI to SCLK setup time 100 - - ns tDH SI to SCLK hold time 20 - - ns tCP SCLK period 250 - - ns CL = 100 pF tCL + tCH tCH SCLK HIGH time 100 - - ns tCL SCLK LOW time 100 - - ns tCSW CS HIGH pulse width 200 - - ns td9 SPI output data valid time 200 - - ns td10 SPI modem output data valid time 200 - - ns td11 SPI transmit interrupt clear time 200 - - ns td12 SPI modem input interrupt clear time 200 - - ns td13 SPI interrupt clear time 200 - - ns td14 SPI receive interrupt clear time 200 - - ns tw(rst) reset pulse width 3 - - s SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 50 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Table 40. SC16IS760 SPI-bus timing specifications All the timing limits are valid within the operating supply voltage, ambient temperature range and output load; VDD = 2.5 V  0.2 V, Tamb = 40 C to +85 C; or VDD = 3.3 V  0.3 V, Tamb = 40 C to +95 C and refer to VIL and VIH with an input voltage of VSS to VDD. All output load = 25 pF, unless otherwise specified. Symbol Parameter Conditions VDD = 2.5 V Min tTR CS HIGH to SO 3-state delay time CL = 100 pF VDD = 3.3 V Max Min Unit Max - 100 - 100 ns tCSS CS to SCLK setup time 100 - 100 - ns tCSH CS to SCLK hold time 5 - 5 - ns tDO SCLK fall to SO valid delay time - 25 - 20 ns tDS SI to SCLK setup time 10 - 10 - ns tDH SI to SCLK hold time 10 - 10 - ns tCP SCLK period 83 - 67 - ns tCH SCLK HIGH time 30 - 25 - ns tCL SCLK LOW time 30 - 25 - ns tCSW CS HIGH pulse width 200 - 200 - ns td9 SPI output data valid time 200 - 200 - ns td10 SPI modem output data valid time 200 - 200 - ns td11 SPI transmit interrupt clear time 200 - 200 - ns CL = 100 pF tCL + tCH td12 SPI modem input interrupt clear time 200 - 200 - ns td13 SPI interrupt clear time 200 - 200 - ns td14 SPI receive interrupt clear time 200 - 200 - ns tw(rst) reset pulse width 3 - 3 - s CS tCSH tCL tCSS tCH tCSH tCSW SCLK tDH tDS SI tDO tTR SO 002aab066 Fig 35. Detailed SPI-bus timing SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 51 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 D6 D5 D4 D3 D2 D1 D0 td9 GPIOx 002aab438 R/W = 0; A[3:0] = IOState (0x0B); CH1 = 0; CH0 = 0 Fig 36. SPI write IOState to GPIO switch (SC16IS750 and SC16IS760 only) CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 D6 D5 D4 D3 D2 D1 D0 td10 DTR (GPIO5) 002aab439 R/W = 0; A[3:0] = MCR (0x04); CH1 = 0; CH0 = 0 Fig 37. SPI write MCR to DTR output switch (SC16IS750 and SC16IS760 only) CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 D6 D5 D4 D3 D2 D1 D0 SO td11 IRQ 002aab440 R/W = 0; A[3:0] = THR (0x00); CH1 = 0; CH0 = 0 Fig 38. SPI write THR to clear TX INT SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 52 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 SO D6 D5 D4 D3 D2 D1 D0 td12 IRQ 002aab441 R/W = 1; A[3:0] = MSR (0x06); CH1 = 0; CH0 = 0 Fig 39. Read MSR to clear modem INT (SC16IS750 and SC16IS760 only) CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 SO D6 D5 D4 D3 D2 D1 D0 td13 IRQ 002aab442 R/W = 1; A[3:0] = IOState (0x0B); CH1 = 0; CH0 = 0 Fig 40. Read IOState to clear GPIO INT (SC16IS750 and SC16IS760 only) CS SCLK SI R/W A3 A2 A1 A0 CH1 CH0 X D7 SO D6 D5 D4 D3 D2 D1 D0 td14 IRQ 002aab443 R/W = 1; A[3:0] = RHR (0x00); CH1 = 0; CH0 = 0 Fig 41. Read RHR to clear RX INT SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 53 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 15. Package outline TSSOP16: plastic thin shrink small outline package; 16 leads; body width 4.4 mm SOT403-1 E D A X c y HE v M A Z 9 16 Q (A 3) A2 A A1 pin 1 index θ Lp L 1 8 e detail X w M bp 0 2.5 5 mm scale DIMENSIONS (mm are the original dimensions) UNIT A max. A1 A2 A3 bp c D (1) E (2) e HE L Lp Q v w y Z (1) θ mm 1.1 0.15 0.05 0.95 0.80 0.25 0.30 0.19 0.2 0.1 5.1 4.9 4.5 4.3 0.65 6.6 6.2 1 0.75 0.50 0.4 0.3 0.2 0.13 0.1 0.40 0.06 8o o 0 Notes 1. Plastic or metal protrusions of 0.15 mm maximum per side are not included. 2. Plastic interlead protrusions of 0.25 mm maximum per side are not included. OUTLINE VERSION SOT403-1 REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 99-12-27 03-02-18 MO-153 Fig 42. Package outline SOT403-1 (TSSOP16) SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 54 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR HVQFN24: plastic thermal enhanced very thin quad flat package; no leads; 24 terminals; body 4 x 4 x 0.85 mm A B D SOT616-3 terminal 1 index area A A1 E c detail X e1 C 1/2 e e 12 y y1 C v M C A B w M C b 7 L 13 6 e e2 Eh 1/2 e 1 18 terminal 1 index area 24 19 X Dh 0 2.5 5 mm scale DIMENSIONS (mm are the original dimensions) UNIT A(1) max. A1 b c D (1) Dh E (1) Eh e e1 e2 L v w y y1 mm 1 0.05 0.00 0.30 0.18 0.2 4.1 3.9 2.75 2.45 4.1 3.9 2.75 2.45 0.5 2.5 2.5 0.5 0.3 0.1 0.05 0.05 0.1 Note 1. Plastic or metal protrusions of 0.075 mm maximum per side are not included. REFERENCES OUTLINE VERSION IEC JEDEC JEITA SOT616-3 --- MO-220 --- EUROPEAN PROJECTION ISSUE DATE 04-11-19 05-03-10 Fig 43. Package outline SOT616-3 (HVQFN24) SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 55 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR TSSOP24: plastic thin shrink small outline package; 24 leads; body width 4.4 mm D SOT355-1 E A X c HE y v M A Z 13 24 Q A2 (A 3) A1 pin 1 index A θ Lp L 1 12 detail X w M bp e 0 2.5 5 mm scale DIMENSIONS (mm are the original dimensions) UNIT A max. A1 A2 A3 bp c D (1) E (2) e HE L Lp Q v w y Z (1) θ mm 1.1 0.15 0.05 0.95 0.80 0.25 0.30 0.19 0.2 0.1 7.9 7.7 4.5 4.3 0.65 6.6 6.2 1 0.75 0.50 0.4 0.3 0.2 0.13 0.1 0.5 0.2 8o 0o Notes 1. Plastic or metal protrusions of 0.15 mm maximum per side are not included. 2. Plastic interlead protrusions of 0.25 mm maximum per side are not included. OUTLINE VERSION SOT355-1 REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 99-12-27 03-02-19 MO-153 Fig 44. Package outline SOT355-1 (TSSOP24) SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 56 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 16. Handling information All input and output pins are protected against ElectroStatic Discharge (ESD) under normal handling. When handling ensure that the appropriate precautions are taken as described in JESD625-A or equivalent standards. 17. Soldering of SMD packages This text provides a very brief insight into a complex technology. A more in-depth account of soldering ICs can be found in Application Note AN10365 “Surface mount reflow soldering description”. 17.1 Introduction to soldering Soldering is one of the most common methods through which packages are attached to Printed Circuit Boards (PCBs), to form electrical circuits. The soldered joint provides both the mechanical and the electrical connection. There is no single soldering method that is ideal for all IC packages. Wave soldering is often preferred when through-hole and Surface Mount Devices (SMDs) are mixed on one printed wiring board; however, it is not suitable for fine pitch SMDs. Reflow soldering is ideal for the small pitches and high densities that come with increased miniaturization. 17.2 Wave and reflow soldering Wave soldering is a joining technology in which the joints are made by solder coming from a standing wave of liquid solder. The wave soldering process is suitable for the following: • Through-hole components • Leaded or leadless SMDs, which are glued to the surface of the printed circuit board Not all SMDs can be wave soldered. Packages with solder balls, and some leadless packages which have solder lands underneath the body, cannot be wave soldered. Also, leaded SMDs with leads having a pitch smaller than ~0.6 mm cannot be wave soldered, due to an increased probability of bridging. The reflow soldering process involves applying solder paste to a board, followed by component placement and exposure to a temperature profile. Leaded packages, packages with solder balls, and leadless packages are all reflow solderable. Key characteristics in both wave and reflow soldering are: • • • • • • Board specifications, including the board finish, solder masks and vias Package footprints, including solder thieves and orientation The moisture sensitivity level of the packages Package placement Inspection and repair Lead-free soldering versus SnPb soldering 17.3 Wave soldering Key characteristics in wave soldering are: SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 57 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR • Process issues, such as application of adhesive and flux, clinching of leads, board transport, the solder wave parameters, and the time during which components are exposed to the wave • Solder bath specifications, including temperature and impurities 17.4 Reflow soldering Key characteristics in reflow soldering are: • Lead-free versus SnPb soldering; note that a lead-free reflow process usually leads to higher minimum peak temperatures (see Figure 45) than a SnPb process, thus reducing the process window • Solder paste printing issues including smearing, release, and adjusting the process window for a mix of large and small components on one board • Reflow temperature profile; this profile includes preheat, reflow (in which the board is heated to the peak temperature) and cooling down. It is imperative that the peak temperature is high enough for the solder to make reliable solder joints (a solder paste characteristic). In addition, the peak temperature must be low enough that the packages and/or boards are not damaged. The peak temperature of the package depends on package thickness and volume and is classified in accordance with Table 41 and 42 Table 41. SnPb eutectic process (from J-STD-020C) Package thickness (mm) Package reflow temperature (C) Volume (mm3) < 350  350 < 2.5 235 220  2.5 220 220 Table 42. Lead-free process (from J-STD-020C) Package thickness (mm) Package reflow temperature (C) Volume (mm3) < 350 350 to 2000 > 2000 < 1.6 260 260 260 1.6 to 2.5 260 250 245 > 2.5 250 245 245 Moisture sensitivity precautions, as indicated on the packing, must be respected at all times. Studies have shown that small packages reach higher temperatures during reflow soldering, see Figure 45. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 58 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR maximum peak temperature = MSL limit, damage level temperature minimum peak temperature = minimum soldering temperature peak temperature time 001aac844 MSL: Moisture Sensitivity Level Fig 45. Temperature profiles for large and small components For further information on temperature profiles, refer to Application Note AN10365 “Surface mount reflow soldering description”. 18. Abbreviations Table 43. SC16IS740_750_760 Product data sheet Abbreviations Acronym Description CPU Central Processing Unit FIFO First In, First Out GPIO General Purpose Input/Output I2C-bus Inter IC bus IrDA Infrared Data Association LCD Liquid Crystal Display MIR Medium InfraRed POR Power-On Reset SIR Serial InfraRed SPI Serial Peripheral Interface UART Universal Asynchronous Receiver/Transmitter All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 59 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 19. Revision history Table 44. Revision history Document ID Release date Data sheet status Change notice Supersedes SC16IS740_750_760 v.7 20110609 Product data sheet - SC16IS740_750_760 v.6 Modifications: • Table 1 “Ordering information”: – Added type number SC16IS740IPW/Q900. – Added new Table note 1. • • Figure 5 “Pin configuration for TSSOP16”: added type number SC16IS740IPW/Q900 Table 2 “Pin description”: added (new) Table note [2] and references to it at GPIO0 to GPIO7. • • Added (new) Section 7.4.2 “Power-on sequence”. • Section 7.8 “Programmable baud rate generator”: added second sentence to paragraph following second “Remark”. • Table 10 “SC16IS740/750/760 internal registers”: added (new) Table note [8] and its reference at IOControl bit 3. • • Added (new) Section 8.8 “Scratch Pad Register (SPR)”. • Section 7.6 “Sleep mode”: added second, third, and fourth paragraphs following first “Remark”. Table 36 “Static characteristics”, sub-section “Inputs/outputs GPIO0 to GPIO7”: added specification for “RPU, pull-up resistance” Table 38 “fXTAL dynamic characteristics”: added (new) Table note [3] and its reference at fXTAL maximum value (at VDD = 2.5 V). SC16IS740_750_760 v.6 20080513 Product data sheet - SC16IS740_750_760 v.5 SC16IS740_750_760 v.5 20061116 Product data sheet - SC16IS740_750_760 v.4 SC16IS740_750_760 v.4 20061030 Product data sheet - SC16IS740_750_760 v.3 SC16IS740_750_760 v.3 20060522 Product data sheet - SC16IS740_750_760 v.2 SC16IS740_750_760 v.2 20060330 Product data sheet - SC16IS740_750_760 v.1 SC16IS740_750_760 v.1 (9397 750 14832) 20060104 Product data sheet - - SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 60 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 20. Legal information 20.1 Data sheet status Document status[1][2] Product status[3] Definition Objective [short] data sheet Development This document contains data from the objective specification for product development. Preliminary [short] data sheet Qualification This document contains data from the preliminary specification. Product [short] data sheet Production This document contains the product specification. [1] Please consult the most recently issued document before initiating or completing a design. [2] The term ‘short data sheet’ is explained in section “Definitions”. [3] The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the Internet at URL http://www.nxp.com. 20.2 Definitions Draft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. NXP Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information. Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local NXP Semiconductors sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail. Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between NXP Semiconductors and its customer, unless NXP Semiconductors and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the NXP Semiconductors product is deemed to offer functions and qualities beyond those described in the Product data sheet. 20.3 Disclaimers Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, NXP Semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. In no event shall NXP Semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Notwithstanding any damages that customer might incur for any reason whatsoever, NXP Semiconductors’ aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of NXP Semiconductors. malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. NXP Semiconductors accepts no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Customers are responsible for the design and operation of their applications and products using NXP Semiconductors products, and NXP Semiconductors accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the NXP Semiconductors product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. NXP Semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). NXP does not accept any liability in this respect. Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device. Terms and conditions of commercial sale — NXP Semiconductors products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nxp.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NXP Semiconductors hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of NXP Semiconductors products by customer. Right to make changes — NXP Semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof. No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights. Suitability for use — NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from national authorities. SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 61 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR Non-automotive qualified products — Unless this data sheet expressly states that this specific NXP Semiconductors product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. NXP Semiconductors accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications. In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without NXP Semiconductors’ warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond NXP Semiconductors’ specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies NXP Semiconductors for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond NXP Semiconductors’ standard warranty and NXP Semiconductors’ product specifications. 20.4 Trademarks Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners. I2C-bus — logo is a trademark of NXP B.V. 21. Contact information For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com SC16IS740_750_760 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 7 — 9 June 2011 © NXP B.V. 2011. All rights reserved. 62 of 63 SC16IS740/750/760 NXP Semiconductors Single UART with I2C-bus/SPI interface, 64-byte FIFOs, IrDA SIR 22. Contents 1 2 2.1 2.2 2.3 3 4 5 6 6.1 6.2 7 7.1 7.2 7.2.1 7.2.2 7.3 7.3.1 7.3.2 7.4 7.4.1 7.4.2 7.5 7.5.1 7.5.2 7.6 7.7 7.8 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 8.10 8.11 8.12 8.13 8.14 8.15 8.16 General description . . . . . . . . . . . . . . . . . . . . . . 1 Features and benefits . . . . . . . . . . . . . . . . . . . . 1 General features . . . . . . . . . . . . . . . . . . . . . . . . 1 I2C-bus features . . . . . . . . . . . . . . . . . . . . . . . . 2 SPI features . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Ordering information . . . . . . . . . . . . . . . . . . . . . 3 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Pinning information . . . . . . . . . . . . . . . . . . . . . . 6 Pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . 7 Functional description . . . . . . . . . . . . . . . . . . . 9 Trigger levels . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Hardware flow control . . . . . . . . . . . . . . . . . . . . 9 Auto RTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Auto CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Software flow control . . . . . . . . . . . . . . . . . . . 11 RX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Reset and power-on sequence. . . . . . . . . . . . 13 Hardware reset, Power-On Reset (POR) and software reset . . . . . . . . . . . . . . . . . . . . . 13 Power-on sequence . . . . . . . . . . . . . . . . . . . . 14 Interrupts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Interrupt mode operation . . . . . . . . . . . . . . . . 16 Polled mode operation . . . . . . . . . . . . . . . . . . 16 Sleep mode . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Break and time-out conditions . . . . . . . . . . . . 17 Programmable baud rate generator . . . . . . . . 18 Register descriptions . . . . . . . . . . . . . . . . . . . 20 Receive Holding Register (RHR) . . . . . . . . . . 23 Transmit Holding Register (THR) . . . . . . . . . . 23 FIFO Control Register (FCR) . . . . . . . . . . . . . 23 Line Control Register (LCR) . . . . . . . . . . . . . . 24 Line Status Register (LSR) . . . . . . . . . . . . . . . 26 Modem Control Register (MCR) . . . . . . . . . . . 27 Modem Status Register (MSR) . . . . . . . . . . . . 28 Scratch Pad Register (SPR) . . . . . . . . . . . . . . 28 Interrupt Enable Register (IER) . . . . . . . . . . . 29 Interrupt Identification Register (IIR). . . . . . . . 30 Enhanced Features Register (EFR) . . . . . . . . 31 Division registers (DLL, DLH) . . . . . . . . . . . . . 31 Transmission Control Register (TCR). . . . . . . 32 Trigger Level Register (TLR) . . . . . . . . . . . . . 32 Transmitter FIFO Level register (TXLVL) . . . . 32 Receiver FIFO Level register (RXLVL) . . . . . . 33 8.17 8.18 8.19 8.20 8.21 9 9.1 9.2 9.3 9.3.1 9.3.2 10 10.1 10.2 10.3 10.4 11 12 13 14 15 16 17 17.1 17.2 17.3 17.4 18 19 20 20.1 20.2 20.3 20.4 21 22 Programmable I/O pins Direction register (IODir) . . . . . . . . . . . . . . . . . . . . . . . . Programmable I/O pins State Register (IOState). . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Interrupt Enable Register (IOIntEna) . . . . I/O Control register (IOControl) . . . . . . . . . . . Extra Features Control Register (EFCR) . . . . RS-485 features . . . . . . . . . . . . . . . . . . . . . . . . Auto RS-485 RTS control . . . . . . . . . . . . . . . RS-485 RTS output inversion . . . . . . . . . . . . Auto RS-485 . . . . . . . . . . . . . . . . . . . . . . . . . Normal multidrop mode . . . . . . . . . . . . . . . . . Auto address detection . . . . . . . . . . . . . . . . . I2C-bus operation . . . . . . . . . . . . . . . . . . . . . . Data transfers . . . . . . . . . . . . . . . . . . . . . . . . Addressing and transfer formats . . . . . . . . . . Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . Use of subaddresses . . . . . . . . . . . . . . . . . . . SPI operation . . . . . . . . . . . . . . . . . . . . . . . . . . Limiting values . . . . . . . . . . . . . . . . . . . . . . . . Static characteristics . . . . . . . . . . . . . . . . . . . Dynamic characteristics. . . . . . . . . . . . . . . . . Package outline. . . . . . . . . . . . . . . . . . . . . . . . Handling information . . . . . . . . . . . . . . . . . . . Soldering of SMD packages . . . . . . . . . . . . . . Introduction to soldering. . . . . . . . . . . . . . . . . Wave and reflow soldering. . . . . . . . . . . . . . . Wave soldering . . . . . . . . . . . . . . . . . . . . . . . Reflow soldering . . . . . . . . . . . . . . . . . . . . . . Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . Revision history . . . . . . . . . . . . . . . . . . . . . . . Legal information . . . . . . . . . . . . . . . . . . . . . . Data sheet status . . . . . . . . . . . . . . . . . . . . . . Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . Disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . Contact information . . . . . . . . . . . . . . . . . . . . Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 33 33 34 35 35 35 36 36 36 36 37 37 38 41 41 43 44 45 47 54 57 57 57 57 57 58 59 60 61 61 61 61 62 62 63 Please be aware that important notices concerning this document and the product(s) described herein, have been included in section ‘Legal information’. © NXP B.V. 2011. All rights reserved. For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com Date of release: 9 June 2011 Document identifier: SC16IS740_750_760
SC16IS740IPW,112 价格&库存

很抱歉,暂时无法提供与“SC16IS740IPW,112”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SC16IS740IPW,112
  •  国内价格 香港价格
  • 1+29.799051+3.69656
  • 10+26.7455010+3.31777
  • 96+21.9170196+2.71880
  • 288+20.79279288+2.57934
  • 576+18.65726576+2.31443
  • 1056+15.735051056+1.95193
  • 2592+14.948242592+1.85433
  • 5088+14.386295088+1.78462

库存:2915