J2R0011-38-21 l
REED SWITCH
ORD211
Ultra-miniature
n GENERAL DESCRIPTION The ORD211 is a small single-contact reed switch designed for general control of low-level loads less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed switches are suited to applications in radio frequency operation. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm)
f0.4 MAX f2.0
MAX 10.0
35.7±0.3
n APPLICATIONS l Automotive electronic devices l Control equipment l Communication equipment l Measurement equipment l Household appliances
39
l ORD211
n ELECTRICAL CHARACTERISTICS
Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current
Rated value 10∼40 5min 100max 150min 109min 0.2max 1.0 24 ( DC ) AC 0.1 0.3
Unit AT AT mW VDC W pF VA V A A
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
99.9
Cumulative frequency percent (%) (Measurement length: 22mm)
AT 50
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 40 60 80 100 mW
Drop-out Value
40
30
20
10
0
10
20
30
40
50
AT
Pull-in Value
Contact resistance
40
ORD211 l
(3) Breakdown voltage
(4) Insulation resistance
99.9 Cumulative frequency percent (%) 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 1010 W (DC 100V)
DC:V 400
Breakdown voltage
300
200
100
0
10
20
30
Pull-in Value
40
50
AT
1011
1012
1013
1014
Insulation resistance
(5) Electrostatic capacitance
(1MHz) pF
Electrostatic capacitance
0.4
0.3
0.2
0.1
0
10
20
30
Pull-in Value
40
50
AT
41
l ORD211
n OPERATING CHARACTERISTICS
Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency Rated value 0.3max 0.3max 0.05max 7500±500 500 Unit ms ms ms Hz Hz
(1) Operate time
(25 Hz: 100AT energized)
(2) Bounce time
99.9
ms 0.5
(25Hz: 100AT energized)
99
Cumulative frequency percent (%)
95 90 80 70 60 50 40 30 20 10 5 1 0.1
0.4
Operate time
0.3
0.2
0.1
0
10
20
30
40
50
AT
0
0.1
0.2
0.3
0.4
ms
Pull-in Value
Bounce time
(3) Release time
(4) Resonant frequency
99.9 99 Cumulative frequency percent (%)
AT
(25Hz: 100AT energized)
µs 15
95 90 80 70 60 50 40 30 20 10 5 1 0.1 7000 7500 8000 Resonant frequency Hz
Release time
10
5
0
10
20
30
40
50
Drop-out Value
42
ORD211 l
n MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(Measurement length: 22mm)
(2) Lead tensile strength
99.9 99
Cumulative frequency percent (%)
AT 60
Pull-in Value・Drop-out Value
50
95 90 80 70 60 50 40 30 20 10 5 1 0.1
0 2 4 6 8 10kg
40
30 PI 20 DO 10
0
Contact resistance
Breaking load
mW 80 CR
60
40
Before test After test
n ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
% 40 CR
30
Rate of change percent
20
DO PI
10
0 −10 −20 −30
−40
−20
0
20
40
60
80
100
120
℃
Temperature
43
l ORD211
(2) Temperature cycle
(-55℃ to 125℃)
(3) Temperature and humidity cycle
-10℃ to 65℃ 80% to 98%
AT 60
AT 60
Pull-in Value・Drop-out Value Pull-in Value・Drop-out Value
50
50
40 30 PI 20 DO 10
40
30 PI 20 DO 10 0
0
Contact resistance Contact resistance
mW 80 CR
mW 80 CR
60
60
40
Before test After test
40
Before test
After test
(4) High temperature storage test
(+125℃-500H)
AT 60
(5) Low temperature storage test
(-40℃-500H)
AT 60
Pull-in Value・Drop-out Value
Pull-in Value・Drop-out Value
50
50
40
40
30 PI 20 DO 10
30 PI 20 DO 10
0
0
Contact resistance
Contact resistance
mW 80 CR
mW 80 CR 60
60
40
40
Before test After test Before test After test
44
ORD211 l
(6) Shock test 1) Electrical characteristics
(30G: 11ms)
AT 60
2) Misoperation area
(open→close)
G 1500
Pull-in Value・Drop-out Value
50
40
30 PI 20 DO 10
Acceleration
1000
Misoperation area 500
0
Contact resistance
mW 80 CR 60
0
10
20
30
40
50
60
AT
Pull-in Value
40
Before test
After test
(7) Vibration test
(20G: 10∼1000Hz)
AT 60
Pull-in Value・Drop-out Value
50
40
30 PI 20 DO 10
0
Contact resistance
mW 80 CR 60
40
Before test After test
45
l ORD211
n LIFE EXPECTANCY DATA: ORD211
(%) 99.9 Cumulative Cumulative failure rate 90 70 50 30 10 5 No failure 5mA 1mA 100µA
Load conditions Voltage: 5VDC Current: 100 µA, 1 mA, 5 mA Load: Resistive load
1
0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations * Arrow indicates number of operations where test was completed.
(%) 99.9 Cumulative failure rate 90 70 50 30 10 5 No failure 100mA 10mA 5mA
Load conditions Voltage: 12VDC Current: 5 mA, 10 mA, 100 mA Load: Resistive load
1
0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations * Arrow indicates number of operations where test was completed.
(%) 99.9 Cumulative failure rate 90 70 50 30 10 5 No failure 50mA 10mA 1mA
Load conditions Voltage: 24VDC Current: 1 mA, 10 mA, 50 mA Load: Resistive load
1
0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations * Arrow indicates number of operations where test was completed.
46
很抱歉,暂时无法提供与“ORD211”相匹配的价格&库存,您可以联系我们找货
免费人工找货