High Power Long Life
n GENERAL DESCRIPTION The ORD312 is a small single-contact reed switch designed for general control of medium level loads less than 200 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed switches are suited to applications in radio frequency operation. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm)
f0.5 MAX f2.0
MAX 12.0
44.3±0.3
n APPLICATIONS l Automotive electronic devices l Control equipment l Communication equipment l Measurement equipment l Household appliances
175
l ORD312 ORD312
n ELECTRICAL CHARACTERISTICS
Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current
Rated value 10∼30 5min 100max 250min 109min 0.3max 30 200DC 100AC 0.5 1.0
Unit AT AT mW VDC V W pF VA V A A
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
99.9 (Measurement length: 32mm)
Cumulative frequency percent (%)
AT 50
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 100 120 140 160 180 mW
Drop-out Value
40
30
20
10
0
10
20
30 Pull-in Value
40
50
60 AT
Contact resistance
176
ORD312 l
(3) Breakdown voltage
(4) Insulation resistance
99.9
Cumulative frequency percent (%)
(DC 100V)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 10
11 12 13 14
DC:V 400 Breakdown voltage
300
200
100
0
10
20
30 Pull-in Value
40
50
AT
10
10
10
10
W
Insulation resistance
(5) Electrostatic capacitance
(1MHz) pF Electrostatic capacitance 0.4
0.3
0.2
0.1
0
10
20
30 Pull-in Value
40
50
AT
177
l ORD312
n OPERATING CHARACTERISTICS
Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency Rated value 0.4max 0.3max 0.05max 5900±400 500 Unit ms ms ms Hz Hz
(1) Operate time
(25Hz: 100AT energized)
(2) Bounce time
(25Hz: 100AT energized)
99.9
Cumulative frequency percent (%)
ms 0.5
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 0.1 0.2 0.3 0.4 ms
0.4 Operate time
0.3
0.2
0.1
0
10
20
30 Pull-in Value
40
50
AT
Bounce time
(3) Release time
(4) Resonant frequency
99.9
Cumulative frequency percent (%)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1
(25Hz: 100AT energized) ms 15
Release time
10
5
0
10
20
30
40
50
AT
5500
6000
6500
Hz
Drop-out Value
Resonant frequency
178
ORD312 l
n MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2.27kg-10sec)
(2) Lead tensile strength
99.9
AT 60
Cumulative frequency percent (%)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 2 4 6 8 10kg Breaking load
Pull-in Value • Drop-out Value
50
40
30
PI DO
20
10
0 Contact resistance
80
60
CR
40
Before test After test
n ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
%
40
30 CR Rate of change percent 20
10
DO PI
0
−10 −20 −30
−40
−20
0
20
40 Temperature
60
80
100
120
140
℃
179
l ORD312
(2) Temperature cycle
(-55℃∼+125 ℃) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value
(3) Temperature and humidity cycle
-10℃∼+65℃ 80%∼98% AT 60
50
50
40
40
30
PI DO
30
PI DO
20
20
10
10
0 Contact resistance mW 100
0 Contact resistance mW 100
80
CR
80
CR
60
Before test After test
60
Before test After test
(4) High temperature storage test
(+125℃-500H) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value AT 60
(5) Low temperature storage test
(-40℃-500H)
50
50
40
40
30
PI DO
30
PI DO
20
20
10
10
0 Contact resistance Contact resistance mW 100
0 mW 100
80
CR
80
CR
60
Before test After test
60
Before test After test
180
ORD312 l
(6) Shock test 1) Electrical characteristics
(30G: 11ms) AT 60 Pull-in Value • Drop-out Value
2) Misoperation area
(open→close)
G 1500
50
40
30
PI DO
Acceleration
1000 Misoperation area
20
10
500
0 Contact resistance mW 100
CR
80
0
10
20
30
40
50
60
AT
Pull-in Value
60
Before test After test
(7) Vibration test
(20G: 10∼1000Hz) AT 60 Pull-in Value • Drop-out Value
50
40
30
PI DO
20
10
0 Contact resistance mW 100
CR
80
60
Before test After test
181
l ORD312
n LIFE EXPECTANCY DATA: ORD312
(%) 99.9 90 70 50 30 10 5
No failure 20mA 10mA 100mA
Load conditions Voltage: 5VDC Current: 100mA, 10mA, 20mA Load: Resistive load
Cumulative failure rate
1
0.1 0
23
5 7 106
23
5 7 107
23
5 7 108
23
5 7 109
Number of operations * Arrow indicates number of operations where test was completed.
(%) 99.9 90 70 50 30 10 5
No failure
Load conditions Voltage: 12VDC Current: 5mA, 10mA, 100mA Load: Resistive load
Cumulative failure rate
100mA
10mA
5mA
1
0.1 0
23
5 7 106
23
5 7 107
23
5 7 108
23
5 7 109
Number of operations * Arrow indicates number of operations where test was completed.
Cumulative failure rate 200mA 100mA
(%) 99.9 90 70 50 30 10 5
150mA
50mA
10mA
Load conditions Voltage: 200VDC Current: 10mA, 50mA, 150mA Load: Resistive load
1
0.1 0
23
5 7 105
23
5 7 106
23
5 7 107
23
5 7 108
Number of operations * Arrow indicates number of operations where test was completed.
182