Small Enclosed Switches
VE
CSM_VE_DS_E_2_2
Small, Lightweight Enclosed
Switches
• V-series Switches were placed in diecast cases to provide
superior dust resistance and mechanical strength.
• Cam arms and cam roller arms can be set to any position
within 360°
Be sure to read Safety Precautions on page 4 and Precautions for
All Limit Switches.
Model Number Legend
Model Number Structure (Some combinations may not be available. Contact your OMRON sales representative for details.)
@VE-10@-@-@
1
2
3
4
1. Number of Built-in
Switches
3. Operation Direction
(for Arm Actuators Only)
1: 1
Blank: Plunger
11:
Counterclockwise operation
(one-side operation)
12:
Clockwise operation
(one-side operation)
13:
Operation in both directions
(two-side operation)
2. Actuator Type
N: Sealed plunger
CA: Cam arm
CA2: Cam roller arm
4. Bushing Type
Blank: Rubber bushing for single-core vinyl cables
C: Rubber bushing for vinyl cabtire cable
Note: For details, refer to Safety Precautions on page 4.
Ordering Information
Actuator type
Operating direction
One built-in switch
Model
Sealed plunger
---
Cam arm
1VE-10N
Counterclockwise
operation
1VE-10CA-11
Clockwise
operation
1VE-10CA-12
Two-side operation 1VE-10CA-13
Cam roller arm
Counterclockwise
operation
1VE-10CA2-11
Clockwise
operation
1VE-10CA2-12
Two-side operation 1VE-10CA2-13
1
VE
Ratings and Specifications
Ratings
Non-inductive load (A)
Resistive load
NC
NO
Inductive load (A)
Lamp load
NC
NO
Inductive load
NC
NO
Motor load
NC
NO
125 AC
250
10
10
2
1.5
10
10
3
2
8 DC
14
30
125
250
10
10
6
0.6
0.3
2
3
3
0.1
0.05
6
6
4
0.6
0.3
6
6
4
0.1
0.05
Durability*
Allowable
operating
frequency
1,500,000 operations min.
Electrical
300,000 operations min. (10 A at 250 VAC, resistive load)
Sealed plunger: 0.1 mm/s to 0.5 m/s
Cam arm: 0.5 mm/s to 0.5 m/s
Cam roller arm: 0.5 mm/s to 0.5 m/s
Mechanical
120 operations/min.
Electrical
60 operations/min.
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value)
Dielectric
strength
24 A max.
NO
24 A max.
Note: 1. The above values are continuous
currents.
2. Inductive loads have a power
factor of 0.4 or higher (AC) or a
time constant of 7 ms or lower
(DC).
3. Lamp loads have an inrush
current of 10 times the steadystate current.
4. Motor loads have an inrush
current of 6 times the steady-state
current.
Switch with Cam Roller Arm Electrical
Durability Graph
IP60
Mechanical
Operating speed
NC
Engineering Data
Characteristics
Degree of protection
Inrush
current
Operations (x 104)
Rated
voltage (V)
Operating frequency: 60 operations/min
Operating angle: 60 degrees
cosφ = 1
200
100
250 VAC
70
50
30
20
Between terminals of
the same polarity
1,000 VAC at 50/60 Hz for 1 minute
Between each terminal
and non-currentcarrying parts
1,500 VAC, 50/60 Hz for 1 minute
10
0
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s2 max., Malfunction: 300 m/s2 max.
Ambient operating temperature
−10°C to 80°C (with no icing)
Ambient operating humidity
35% to 95%
Weight
Approx. 120 to 170 g
2
4
6
8
10
Switching current (A)
Note: The above values are initial values.
* The values are calculated at an operating temperature of 5°C to 35°C and an operating
humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating
environments.
Nomenclature
Structure
Roller
Contact Form
Built-in Switch (V)
COM
NC
NO
Roller arm
Case
Cover
Conduit cap
2
VE
Dimensions/Operating Characteristics The @ in the model numbers is replaced by the operation direction code.
(Unit: mm)
Refer to Model Number Legend on page 1 for details.
Sealed Plunger
1VE-10N
8.3 dia. R12 *1
PT
9.5
Built-in
rubber seal *2
*3
OP
28.6±0.2
39
19.5
5.2
13.1
5
42.8±0.2
53
26.3
Two, 4.7±0.2-dia. holes
70
JIS B 0202 G1/2
Cam Arm
1VE-10CA-@
*1. Stainless steel plunger.
*2. Three,2-dia. holes (1VE-10N).
*3. Conduit cap.
1VE-10CA-@
46.5±0.8
4.7
4.8
42.5
24.5
8.8
37.5±0.8
37
25.3
*1
R: 31.8
3.2-dia. hole
67.5 58.7±0.2
(81.8)
Built-in rubber seal
(three, 2-dia. holes)
*2
Two, 4.7±0.2-dia. holes
*1. The stainless steel arm can be set
to any position within 360°.
*2. Conduit cap.
13.1
26.2±0.2
JIS B 0202 G3/8
19.3
35.5
Cam Roller Arms
1VE-10CA2-@
1VE-10CA2-@
4.7
4.8
9.5 dia. x 4.8 *1
42.5
24.5
46.5±0.8
41.3±0.8
1.8
25.3
3
R:
8.8
67.5 58.7±0.2
(81.8)
Built-in rubber seal
(three, 2-dia. holes)
*2
Two, 4.7±0.2-dia. holes
*1. The stainless steel roller arm
can be set to any position within 360°.
*2. Conduit cap.
13.1
26.2±0.2
JIS B 0202 G3/8
19.3
35.5
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristic
Operating force
Release force
Pretravel
Overtravel
Movement differential
Operating position
1VE-10N
1VE-10CA-@
1VE-10CA2-@
OF max.
RF min.
PT max.
OT min.
MD max.
Model
22.26N
2.23N
2mm
6.3mm
0.8mm
6.69N
1.12N
30°
55°
10°
6.69N
1.12N
30°
55°
10°
OP
61.1±0.8mm
---
---
3
VE
Safety Precautions
Refer to Precautions for All Limit Switches for general precautions.
Precautions for Correct Use
Tightening Torque
Conduit Part: 1VE-10N
If screws are too loose, they can lead to an early malfunction of the
Switch, so ensure that all screws are tightened using the correct
torque.
No.
Type
Rubber
(NBR) bushing
Tightening torque
A
Cover mounting screws
0.49 to 0.59 N·m
B
Body clamping screws
1.18 to 1.37 N·m
Conduit cap
Washer
Cable type
Item
Single-core, vinyl cables
Conduit cap
Rubber bushing*
Vinyl cabtire cable
Conduit cap
Rubber bushing*
Single-core cable
Cabtire cable
Cable outlet
Washer
Accessories for Cable
Connection
Mounting Hole Dimensions
1VE-10CA-@
1VE-10CA2-@
1VE-10N
Two, 4.7-dia. or
M4 screw holes
Two, 4.7-dia. or
M4 screw holes
28.6±0.15
42.8±0.15
26.2±0.15
Operation
• The operating method, shape of cam or dog, operating frequency,
and overtravel have a significant effect on the durability and
precision of the Switch. Make sure that the shape of the cam is
smooth enough.
• Check that OT has a sufficient margin.
Set the overtravel to between 70% and 100% of the specified
overtravel.
• Do not change the operating position by remodeling the actuator.
Wiring
• When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch.
• Sealing materials may deteriorate when used outdoors or when
exposed to cutting oil, solvents, or chemicals. Check this on actual
equipment and, if deterioration is foreseen, consult your OMRON
representative in advance.
• Refer to the following table for the cable connection method.
Rubber bushing, conduit cap,
and washer
Connected
cable speciJIS C 3306
fications
Finished OD: 2.6 to 3.4 mm
and dimensions
Resistance
to water
drops
58.7±0.15
Washer
Case
High: The conduit cap can be
tightened securely when
connecting the cables without
gaps resulting from twisting
or other causes.
Case
Rubber bushing, conduit cap,
and washer
JIS C 3306
Finished OD: 6.6 to 7.6 mm
Good: Sealing is achieved by
using a cable with diameter that
is the same as or slightly larger
than the inner diameter of the
rubber bushing.
Note: The accessories for the single-core vinyl cables are included as
standard features.
Ask your OMRON representative for details on vinyl cabtire
cables (models that contain -C at the end).
* Bushing Types
Model
1VE-10N
Type
1VE-10CA-@
1VE-10CA2-@
Remarks
For single-core,
vinyl cables
Standard product
There is no -C at
the end of the
model number.
For vinyl cabtire
cable
There is a -C at
the end of the
model number.
4
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.