New Product
Sensor Evaluation Board
2JCIE-EV
Sensor evaluation board that
supports open platform
• Easily implement development of a new IoT system
that senses a wide variety of environmental information
RoHS compliant
Refer to Safety Precautions on Page 9.
Features
Easily develop sensing IoT applications and PoC
• Evaluation board with six types of sensing functions.
• The product can be connected to a Raspberry Pi *1, Arduino *2, or Feather *3 baseboard, and enables easy sensor
evaluation.
• The product can be connected to OMRON sensors (MEMS thermal sensor, MEMS flow sensor, Light convergent
reflective sensor, air quality sensor, etc.) and Qwiic sensors.
OMRON sensor evaluation board
Six types of
sensing functions
Can be connected to OMRON
sensors *4
Includes a connector that supports
Qwiic sensors.
Temperature, humidity, light,
barometric pressure, noise, acceleration
+
Can be connected to a variety of sensors
Platform
Supports three platforms
Raspberry Pi *1, Arduino *2, Feather *3
(Raspberry Pi)
+
Sample source code for acquiring sensor data is available on GitHub
*1.
*2.
*3.
*4.
Raspberry Pi is a registered trademark of the Raspberry Pi Foundation.
Arduino is a registered trademark of Arduino LLC and Arduino SRL.
Feather is a registered trademark of Adafruit Industries LLC.
For details, see External Expansion Sensor on page 3.
1
2JCIE-EV
Ordering Information
Unit
Type
Appearance
Supported platform *4
Model
Table of Models
RP type
2JCIE-EV01-RP1
Raspberry Pi *1
3 A/1 B+/2 B/3 B/3 B+/Zero/Zero W *5
AR type
2JCIE-EV01-AR1
Arduino *2
MKR Vidor 4000/MKR WiFi 1010/MKR ZERO *5
FT type
2JCIE-EV01-FT1
Feather *3
HUZZAH32 *5
Supported Accessories (Sold Separately)
Type
Model
2JCIE-HARNESS-01
2JCIE-HARNESS-02
Cable harness
2JCIE-HARNESS-03
2JCIE-HARNESS-04
2JCIE-HARNESS-05
*1. Raspberry Pi is a registered trademark of the Raspberry Pi Foundation.
*2. Arduino is a registered trademark of Arduino LLC and Arduino SRL.
*3. Feather is a registered trademark of Adafruit Industries LLC.
*4. Boards for supported platforms are not included.
*5. Do not use a model other than those listed in each table of platform supporting models.
Note: The temperature sensor on the sensor evaluation board may output a high value due to heat generated by the platform. If you need to
eliminate this effect, either separate the sensor from the unit by connecting a cable or otherwise, or use an external temperate/humidity
sensor that supports SparkFun Qwiic.
Ratings and Specifications
Specifications
Model
2JCIE-EV01-RP1
Item
2JCIE-EV01-FT1
Protocol
Pi HAT
Shield for MKR form factor
Dimensions (mm)
Approx. 65 x 30
Approx. 61.5 x 25
Approx. 50.8 x 23.9
Sparkfun Qwiic (3.3 V I2C)
CN4
CN4
CN4
CN5
CN5
CN5
TH1
TH1
TH1
CN6
CN6
CN7, CN8
TH2
5V I2C for expansion
5V UART for expansion
CN6
5V DIO for expansion
2
2JCIE-EV01-AR1
---
FeatherWing
Sensing data that can be acquired
Temperature, humidity, light, barometric pressure, noise, 3-axis acceleration
Absolute maximum rating: Power voltage (5 V)
-0.2 to 5.5 V
Absolute maximum rating: Power voltage (3.3 V)
-0.2 to 3.6 V
Absolute maximum rating: Input/output terminal voltage (5 V)
-0.2 to 5.2 V
Absolute maximum rating: Input/output terminal voltage (3.3 V)
-0.2 to 3.5 V
Absolute maximum rating: Power current
700 mA
Ambient storage temperature
-10 to 60°C (no condensation or icing)
Ambient storage humidity
30 to 85% (no condensation or icing)
Recommended operating range: Power voltage (5 V)
4.75 to 5.25 V
Recommended operating range: Power voltage (3.3 V)
3.14 to 3.47 V
2JCIE-EV
Equipped Sensor
Part number *
Model
Manufacturer
Interface
U1
Temperature/humidity sensor
Sensor
SHT30-DIS-B
Sensirion
I 2C
U2
Ambient light sensor
OPT3001DNP
Texas Instruments
I2C
U3
MEMS digital barometric pressure sensor
2SMPB-02E
OMRON
I2C
U5
MEMS digital motion sensor
LIS2DW12
STMicroelectronics
SPI
U6
MEMS microphone
SPH0645LM4H-B
Knowles
I2S
* For details, see the terminal layouts on pages 4 to 6.
Note: When using the sensor evaluation board, the accuracy indicated on the data sheet of each sensor manufacturer is not guaranteed.
External Expansion Sensor *1
Product
Manufacturer
Model
Supported connector *2
RP type
AR Type
FT type
Supported accessories
(sold separately)
D6T-44L-06/-H
D6T-8L-09/-H
MEMS Thermal sensor
D6T-1A-01
CN5
2JCIE-HARNESS-01
CN4
2JCIE-HARNESS-02
CN4
2JCIE-HARNESS-03
D6T-1A-02
D6T-32L-01A
D6F-PH0025AD1
OMRON
MEMS flow sensor
D6F-PH0505AD3
D6F-PH5050AD3
D6F-10A7D-000-0
D6F-20A7D-000-0
D6F-50A7D-000-0
D6F-70AB7D-000-0
Light convergent reflective sensor
B5W-LB2101-1
Air quality sensor
B5W-LD00101-1/-2
---
CN8
TH2
2JCIE-HARNESS-04
CN7
TH2
2JCIE-HARNESS-05
Note: When an external expansion sensor is connected to the sensor evaluation board, the current supply ability of the platform board may be
exceeded. Consider suppling power using an external power supply. Check current supply ability in the data sheet and other literature of
each platform board. When using an external power supply, check the Jumper Function information and use jumper switching.
*1. We have checked the operation of typical models of each sensor.
*2. For details, see the terminal layouts on pages 4 to 6.
Software
Access the sample source code that supports each platform from the following URL.
(https://www.components.omron.com/sensor/evaluation-board/2jcie)
Note: 1. The sample source code is for evaluation. OMRON does not guarantee its operation.
2. We bear no responsibility to correct mistakes or bugs in the sample source code for the purpose of changes or any other reason.
3. We cannot accept any inquiries regarding the sample source code.
3
2JCIE-EV
Dimensions
(Unit: mm)
2JCIE-EV01-RP1
(65)
Four, 2.8 dia.
(5.9)
58
1.6
(30) 23
Connection
Terminal Arrangement
Front
2JCIE-EV01-RP1
CN4
CN5
CN9
40
2
39
1
U2
1 23 4
1 23 4
Back
U1
V G
123 456
7
CN6 U3 U5
CN9
1
TH1 TH4
U6
CN4
BM04B-SRSS-TB (JST)
CN5
BM04B-GHS-TB (JST)
CN6
BM06B-SRSS-TB (JST)
1
3.3 VDC *1
2
5 VDC *2
3
SDA *1
4
NC
1
SCL
1
GND
1
5 VDC
SDA
2
5 VDC
2
RXD
5
SCL *1
6
NC
2
7
NC
8
RXD *2
3
3.3 VDC
3
SDA_5V
3
TXD
9
NC
10
TXD *2
4
GND
4
SCL_5V
4
GND
3.3 VDC
NC
11
DIGITAL4 *1
12
BCLK *1
5
13
RDY *2
14
NC
6
15
NC
16
DIGITAL1 *1
17
NC
18
DIGITAL2 *1
19
MOSI *1
20
GND
21
MISO *1
22
DIGITAL3 *1
23
SCLK *1
24
CS *1
TH1
25
NC
26
NC
27
NC
28
NC
29
EN *2
30
NC
31
LED_SW_R *2
32
LED_SW_G *2
33
LED_SW_B *2
34
NC
35
WS *1
36
INT *1
37
INT_LIS2DW12 *1
38
MIC_OUT *1
39
GND
40
NC
TH4
1
5 VDC
19
5 VDC (Ext.)
2
GND
07
GND
3
SCL_5V
4
SDA_5V
5
RDY
6
NC
7
GND
*1. 3.3 V terminal *2. 5.0 V terminal
Block Diagram
2JCIE-EV01-RP1
CN9
I2C
CN4: Connector
Temperature/humidity sensor
Light sensor
Barometric pressure sensor
I2C level conversion
SPI
Acceleration sensor
I2S
Microphone
DIGITAL IN
Level conversion
UART
DIGITAL OUT
or PWM
5V
CN5: Connector
5V
TH1: Through-hole
CN6: Connector
RGB LED
2JCIE-EV01-RP1
4
2JCIE-EV
Dimensions
(Unit: mm)
2JCIE-EV01-AR1
(61.5)
(6.6)
57
Four, 2.3 dia.
1.6
(25) 20.5
Connection
Terminal Arrangement
Front
2JCIE-EV01-AR1
Back
CN6
CN5
CN4
U1
CN11
12 34
14
1 2 3456
TH5
1
1 2 34
U2
1 2 3 4
1 2 345
7
1
14
CN8
CN7
CN11
CN10
TH1
1
CN4
BM04B-SRSS-TB (JST)
4
CN10
U6
U3 U5
B G V
1
TH3
CN5
BM04B-GHS-TB (JST)
TH1
1
NC
1
5 VDC *2
2
DAC *2
2
VBAT *1
1
SCL
1
GND
2
GND
3
PMS_IN *2
3
3.3 VDC *1
2
SDA
2
5 VDC
3
SCL_5V
4
B5WLA01_OUT *2
4
GND
3
3.3 VDC
3
SDA_5V
4
SDA_5V
5
EN *2
5
NC
4
GND
4
SCL_5V
5
RXD-B5W_OUT
6
B5WLA01_IN *2
6
RXD-B5W_OUT *2
6
NC
7
PMS_OUT *2
7
TXD-B5W_OUT *2
7
GND
8
MIC_OUT *1
8
SCL *1
9
CS *1
9
SDA *1
10
INT *1
10
MISO *1
1
5 VDC
11
BCLK *1
11
SCLK *1
2
PMS_IN
12
WS *1
12
3
PMS_OUT
13
LED_SW_R *2
13
NC
4
GND
14
LED_SW_G *2
14
LED_SW_B *2
5 VDC (Ext.)
CN6
BM06B-SRSS-TB (JST)
MOSI *1
CN7
BM05B-SRSS-TB (JST)
1
5 VDC
1
5 VDC
2
RXD-B5W_OUT
2
TXD-B5W_OUT
3
TXD-B5W_OUT
3
GND
4
GND
4
DAC
5
3.3 VDC
5
RXD-B5W_OUT
6
NC
1
TH3
CN8
B4B-ZR-SM4-TF (JST)
*1. 3.3 V terminal *2. 5.0 V terminal
5 VDC
TH5
1
B5WLA01_IN
19
2
GND
07
GND
3
B5WLA01_OUT
B
VBAT
4
5 VDC
Block Diagram
2JCIE-EV01-AR1
CN10
CN11
I2C
CN4: Connector
Temperature/humidity sensor
Light sensor
Barometric pressure sensor
I2C level conversion
SPI
Acceleration sensor
I2S
Microphone
5V
CN5: Connector
TH1: Through-hole
UART
CN6: Connector
ANALOG IN
DIGITAL I/O
DIGITAL OUT
TH3: Through-hole
Level conversion
5V
CN8: Connector
DIGITAL I/O
DIGITAL IN
Level conversion
5V
CN7: Connector
DAC
DIGITAL OUT
or PWM
RGB LED
2JCIE-EV01-AR1
5
2JCIE-EV
Dimensions
(Unit: mm)
2JCIE-EV01-FT1
(50.8)
(5.9)
45.7
24
Four, 2.5 dia.
1.6
(23.86)
(22.86)
17.78
Connection
Terminal Arrangement
2JCIE-EV01-FT1
Front
CN6
U1
CN4
Back
1
1 2 3 4
12
123456
TH5 TH1
TH2
CN10
B
1
7
16
CN4
BM04B-SRSS-TB (JST)
CN5
U5
1
1
U6
CN11
TH1
TH2
CN5
BM04B-GHS-TB (JST)
1
NC
1
5 VDC
1
5 VDC
CN11
1
SCL
1
GND
2
3.3 VDC *1
2
GND
2
DAC
2
SDA
2
5 VDC
3
NC
3
SCL_5V
3
RXD-B5W_OUT
3
3.3 VDC
3
SDA_5V
4
GND
4
SDA_5V
4
TXD-B5W_OUT
4
GND
4
SCL_5V
5
DAC *2
5
TXD-B5W_OUT
5
B5WLA01_IN
6
LED_SW_B *2
6
NC
6
PMS_B5WLA01_OUT
7
INT *1
7
GND
7
PMS_IN
8
PMS_B5WLA01_OUT
9
GND
CN6
BM06B-SRSS-TB (JST)
CN10
1
VBAT *1
8
NC
1
5 VDC
2
NC
9
PMS_IN *2
2
RXD-B5W_OUT
3
5 VDC *2
10
CS *1
19
GND
3
TXD-B5W_OUT
4
B5WLA01_IN *2
11
SCLK *1
07
5 VDC (Ext.)
4
GND
5
LED_SW_R *2
12
MOSI *1
B
VBAT
5
3.3 VDC
6
LED_SW_G *2
13
MISO *1
6
NC
7
PMS_B5WLA01_
OUT *2
14
TXD-B5W_OUT *2
15
WS *1
RXD-B5W_OUT *2
8
16
MIC_OUT1 *1
EN *2
9
10
BCLK *1
11
SCL *1
12
SDA *1
TH5
*1. 3.3 V terminal *2. 5.0 V terminal
Block Diagram
2JCIE-EV01-FT1
CN10
CN11
I 2C
CN4: Connector
Temperature/humidity sensor
Light sensor
Barometric pressure sensor
I2C level conversion
SPI
I2S
5V
CN5: Connector
Acceleration sensor
TH1: Through-hole
Microphone
UART
CN6: Connector
ANALOG IN
DIGITAL I/O
DIGITAL OUT
Level conversion
DIGITAL IN
Level conversion
5V
5V
TH2: Through-hole
DAC
DIGITAL OUT
RGB LED
2JCIE-EV01-FT1
6
G
U2
1234
9
U3
V
2JCIE-EV
Dimensions
(Unit: mm)
Cable harness (option)
2JCIE-HARNESS-01
440±10
500±10
2JCIE-HARNESS-02
440±10
500±10
2JCIE-HARNESS-03
440±10
500±10
2JCIE-HARNESS-04
440±10
500±10
2JCIE-HARNESS-05
440±10
500±10
7
2JCIE-EV
Jumper Function (Power Related)
No.
Positions
Meaning
JP1
Application
When supplying power from the platform board
Front
JP2
Zero-ohm resistance
When power is supplied from an external power supply or battery
(Only the 2JCIE-EV01-AR1/FT1 supports batteries)
Default
Status
Connected
Enabled
Open
Disabled
• When using an external power supply, remove the zero-ohm resistance from JP1 and connect the zero-ohm resistance to JP2 ((1) below).
Connect the power of the external power supply to the V terminal in (2) below, and connect GND to G.
• (2JCIE-EV01-AR1/FT1 only) When using an external battery, connect the battery to B and GND to G. When using a battery, a 5 V input sensor
cannot be used.
• When you switch to JP2, JP1 is disabled and power cannot be supplied from the platform board.
• Do not connect JP1 and JP2 at the same time.
How to switch by jumper
• Remove the zero-ohm resistance from JP1 by soldering arm and mount the JP2 by soldering. (Do not connect by soldering while connected to
a base board or to an external power source)
2JCIE-EV01-FT1 Layout
(2)
(1)
Jumper Function (Output Terminal)
No.
JP5
JP6
Positions
Back
(2JCIE-EV01-AR1/FT1 only)
Meaning
Switch by board pattern
Application
For TH1 expansion
B5W digital output function
Default
Status
Open
Disabled
Connected
Enabled
When connected, the above function is enabled. When open, the above function is disabled.
JP5 and JP6 are paired and cannot both be enabled.
How to switch by jumper
Cut the JP6 connection location (central part) with cutters, and connect the divided parts of JP5 by soldering.
Note: Give full consideration to safety when cutting the jumper. OMRON cannot bear responsibility for any injury or damage that occurs.
Accessories
Type
Model
Pin socket for 2JCIE-EV01-RP1
ESQ-120-12-L-D (SAMTEC)
Pin header for 2JCIE-EV01-AR1
TSW-114-07-L-S (SAMTEC)
Pin socket for 2JCIE-EV01-FT1
ESQ-112-12-L-S (SAMTEC)
ESQ-116-12-L-S (SAMTEC)
Note: To connect this board to the corresponding platform, it must be directly soldered or the pin header or socket must be soldered.
8
2JCIE-EV
Safety Precautions
Precautions for safe use
Read the following to ensure safe use.
The safety precautions that are provided are extremely important to
safety. Always read and heed the information provided in all safety
precautions.
Explanation of safety symbols
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury, or property damage.
Precautions for
Safe Use
Precautions on what to do and what not to
do to ensure safe usage of the product.
Precautions for
Correct Use
Precautions on what to do and what not to
do to ensure proper operation and
performance.
CAUTION
• Do not incorporate this product in a product, regardless of the
application.
• This product is not a measuring instrument. Do not use for
purposes such as sensor output value measurement and
diagnosis.
• When disposing of the product, follow local rules and regulations.
Precautions for Correct Use
• Keep out of the hands of small children when using and storing the
product. If a small part is swallowed, immediately consult a
physician.
• If you notice a strange odor or smoke coming from the product, or
other abnormal condition, immediately shut off the power and
consult your dealer.
• Do not handle this product with your bare hands. Risk of minor
injury from the packaging box and edge of the board.
• Do not connect the indicated terminals or power not listed in this
manual. Check the rating of each terminal, and do not use a current
or voltage that exceeds the rating.
• This product is not waterproof. Do not use in an environment where
water, oil, or chemicals may splash on the product. Do not wash
with water or by ultrasound, and do not touch with wet hands.
• Do use an air blower. This may damage the sensor.
• Do not disassemble or modify the product.
• Do not grasp the product with excessive force, swing it around, or
treat it roughly. Risk of product failure and injury.
• Do not use in an environment where corrosive, flammable, or
explosive gases are present.
Precautions for Correct Use
• Treat the measured values acquired by this product as reference
values.
• Do not connect this product to other than one of the models listed
in each table of platform supporting models.
• The pin headers and sockets below are recommended for this
product. For insertion/removal counts, refer to the latest data sheet /
reliability test results for each pin header or socket.
2JCIE-EV01-RP1: ESQ-120-12-L-D
2JCIE-EV01-AR1: TSW-114-07-L-S
2JCIE-EV01-FT1: ESQ-112-12-L-S
ESQ-116-12-L-S
• When this product is connected to any of the platforms, heat and
other effects from the platform will cause the output of the product
to change. Check these effects sufficiently before using the
product
• Check, understand, and consider the installation location of each
sensor before using the product. Do not use with the area around
each sensor in a sealed state.
• This is a precision product. Exercise caution when handling.
Dropping the packing box or the unit, or subjecting the unit and its
terminals to intense shock may result in product failure.
• Do not use or store the product in a high-temperature or highhumidity location, a location exposed to long hours of direct
sunlight, or in a vehicle. Sudden changes of ambient temperature
may cause internal condensation that results in malfunctioning.
• Do not use or store in a location with dust, salt, or iron powder. Dust
or other contaminants may collect in or on the product and cause
failure.
• Do not use in a location with intense static electricity or
electromagnetic waves. Risk of product failure.
9
MEMO
10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of a week from the date of sale by Omron (or such other period expressed in writing by
Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2019 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. A297-E1-02
1019 (0719)