3G3AX-RAI02800080-DE 数据手册
JX INVERTER
Compact and complete
» Quality & reliability you can depend on
» Co m m u n i c a t i o n s b u i l t- i n
» Cost and eco-friendly
The smallest gets integrated...
Key features include:
Omron fully understands your needs, which
•
Ratings up to 7.5 kW
is why we put quality and reliability first.
•
RS485 Modbus built-in
And we keep listening, so our products come
•
Side-by-side mounting
•
EMC filter built-in
•
PID function
•
Micro-surge voltage suppression
•
Automatic energy saving
With the RFI filter built-in, and the
•
Emergency shut-off
communications integrated as standard, the
•
Second motor setting
•
Auto carrier-frequency reduction
•
PTC thermistor input
•
Cooling fan switch control
•
RoHS
with new features and functionality that save
you time and money.
JX provides a compact and complete solution
to a whole range of simple applications, such
as conveyor control.
2
Level (dBV)
1
OMRON Function Block for Pulse Output Positioning.
OMRON Function Block for Communications.
120
110
100
90
80
70
60
50
40
30
20
10
0
No Filter
Integrated EMC filter
150 200 500k
1M
2M
Conducted emission data
5M 10M 20M 30M
Frequency (Hz)
Easy network integration
Easy communications setting
Space and cost saving
The RS485 Modbus is built into the
RJ45 port in the inverter front,
making it very easy to add inverters
into the network without any extra
option boards. Therefore, saving
money and space.
Modbus commands are implemented
even in low end CP1 PLC family by
Modbus-RTU Easy Master
functionality, making it easier than
ever to integrate the inverters into
the network.
The new JX has a built-in EMC filter
that saves on costs and space
compared with the standard
external filter solution.
1 ph : EN61800-3 cat. C1
3 ph : EN61800-3 cat. C2
Everything on-board
for your application
6
5
3
3
4
Sensor
5
~
Emergency stop switch
Power supply
circuit
IGBT gate
Motor
Sensor?
24 V
Latch
Set EMR
Reset RS
Interruption
PCS
0V
M
Heating section
No additional devices required
Convenient and efficient
Reliable emergency shutdown
Even advanced functionality such as
PID control is standard with the JX
inverter making it a convenient
solution for applications such as
pumps & fans where pressure, flow
and other processes need
controlling.
The parameter settings of two
different motors can be stored,
allowing the inverter to drive
different motors with a unique
inverter. The two motors are never
working at the same time.
The IGBT’s output is directly
switched off from the external input,
assuring no energy is supplied to the
motor. This hardware-based solution
is more reliable than other CPU
dependent solutions.
6
Power (%)
1,250 V
Spikes in the terminal voltage are suppressed even when
the wiring distance from the inverter to the motor is long
90
80
70
60
50
40
30
20
10
0
91%
Damper system
76%
61%
Energy-saving effect
22%
Inverter system
10 20 30 40 50 60 70 80 90 100
Airflow (%)
Silent operation
Maximise motor life
Automatic energy saving
Depending on the inverter
temperature, switching off the fan
creates a noise-free atmosphere and
prolongs the life time of the product.
Advanced PWM control is used to
suppress micro-surge voltages that
sometimes cause malfunction in
400 V motors. The motor is thus
protected and its life is prolonged.
The Inverter always adopts the
optimum energy-saving setting for
cost savings in such applications as
fans and pumps. The inverter can
reduce energy consumption by
61% compared with standard
mechanical systems.
4
Reliability with environmental responsibility
AR
RANT
3
Y
W
Omron is renowned for the reliability of its products.
Moreover, Omron’s policy is to offer environmentally
safe products free from any banned substances.
YEARS
JX
Compact & Complete
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
V/f controlled inverter
Side by side mounting
Built-in EMC filter
Built-in RS-485 Modbus
Overload detection function (150% during 60s)
PID
Micro-surge voltage suppression
Automatic energy saving
Emergency shut-off
Second motor setting
Auto carrier-frequency reduction
PTC thermistor input
Cooling fan switch control
PC configuration tool: CX-Drive
CE, UL, cUL, RoHS
Ratings
• 200 V Class single-phase 0.2 to 2.2 kW
• 200 V Class three-phase 0.2 to 7.5 kW
• 400 V Class three-phase 0.4 to 7.5 kW
System configuration
Power
supply
RJ45 - USB cable
CX-Drive
CX-One
MCCB
Remote operator
extension cable
AC reactor
Filter
LCD 5 lines remote
operator
*
JX
DC reactor
Choke
Motor
Output reactor
Ground
* Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models
6
Frequency inverters
Specifications
Type designation
3G3JX-AB002-EF
JX series
F: Built-in EMC Filter
A:
E: Europe standard
Standard specs
Max. applicable motor output
002: 0,2 kW
~
Voltage:
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
075: 7,5 kW
200 V class
Single-phase: 3G3JX@
AB002
AB004
AB007
AB015
AB022
-
-
-
Three-phase: 3G3JX@
A2002
A2004
A2007
A2015
A2022
A2037
A2055
A2075
Output
characteristics
Motor
kW*1
Applicable motor capacity
Inverter capacity kVA
0.2
0.4
0.75
1.5
2.2
3.7
5.5
7.5
200 V
0.4
0.9
1.3
2.4
3.4
5.5
8.3
11.0
240 V
0.5
1.4
1.0
2.6
1.6
2.9
4.1
6.6
4.0
7.1
10.0
15.9
Proportional to input voltage: 0…240 V
9.9
24.0
13.3
32.0
30.0
–
40.0
–
Rated output current (A)
Max. output voltage
Max. output frequency
400 Hz
Power
supply
Rated input voltage
and frequency
Rated input current (A) Three-phase 200 V
Rated input current (A) Single-phase 200 V
Allowable voltage
fluctuation
Allowable frequency
fluctuation
1.8
3.1
3.4
5.8
-15%…+10%
+5%
EMC filter (C1 single phase)
Built-in filter
Braking torque
At short-time
deceleration
At capacitor
feedback
50% for
3-phase
20 to 40% for
1-phase
Approx. 50%
Approx 20% to 40%
Self cooling
Cooling method
*1
Single-phase 200…240 V 50/60 Hz
3-phase 200…240 V 50/60 Hz
5.2
9.3
13.0
20.0
9.0
16.0
22.5
–
Approx 20%
Forced-air-cooling
Based on a standard 3-Phase standard motor.
400 V class
Three-phase: 3G3JX@
Power
supply
Output
characteristics
Motor
kW*1
A4004
A4007
A4015
A4022
A4040
A4055
A4075
0.4
0.75
1.5
2.2
4.0
5.5
7.5
380 V
0.9
1.6
2.5
3.6
5.6
480 V
1.2
1.5
2.0
2.5
Applicable motor capacity
Inverter capacity kVA
Rated output current (A)
Max. output voltage
Max. output frequency
13.3
16.0
3.3
5.0
7.0
11.0
16.5
20.0
-15%…+10%
+5%
EMC filter C2 class
At short-time
deceleration
At capacitor
feedback
Cooling method
JX
10.5
3-phase 380…480 V 50/60 Hz
2.0
Built-in filter
*1
8.5
10.8
13.0
400 Hz
Rated input voltage
and frequency
Rated input current (A)
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Braking torque
3.1
4.5
7.1
3.8
5.5
8.6
Proportional to input voltage: 0…480 V
Approx. 50%
Self cooling
Approx. 20% to 40%
Approx. 20%
Forced-air-cooling
Based on a standard 3-Phase standard motor.
7
Specifications
Common specifications
Control functions
Model number
3G3JX@
Control methods
Phase-to-phase sinusoidal modulation PWM (V/f)
Output frequency range
0.5..400 Hz
Digital set value: ±0.01% of the max. frequency
Analogue set value: ±0.4% of the max. frequency (25 ±10 ºC)
Digital set value: 0.1 Hz
Resolution of frequency set value
Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.1 Hz
150% rated output current for one minute
Overload capability
Frequency precision
Frequency set value
V/f Characteristics
Functionality
Protection functions
Constant/ reduced torque
Analogue inputs
Accel/Decel times
0.01 to 3000 s (line/curve selection), 2nd accel/decel setting available
Output signals
Standard functions
Motor overload protection
Status indicator LED’s Run, Program, Power, Alarm, Power, Hz, Amps, Volume Led indicator
Digital operator: Available to monitor frequency reference, output current, output frequency
Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent
180% of rated current
Overload
150% for 1 minute
Overvoltage
790 V for 400 V type and 395 for 200 V type
Momentary power loss
Following items are selectable: Alarm, 0 Hz start, frequency output at interruption, maximum frequency
Cooling fin overheat
Temperature monitor and error detection
Stall prevention level
Selectable level applicable only at constant speed or during acceleration and constant speed
Ground fault
Detected at power-on
Power charge indication
On when power is supplied to the control part
Degree of protection
IP20
Ambient humidity
90% RH or less (without condensation)
Storage temperature
-20ºC..+65 ºC (short-term temperature during transportation)
Ambient temperature
10C to 50C (Both the carrier frequency and output current need to be reduced at over 40C.)
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Max. 1000 m
Vibration
5.9 m/s2 (0.6 G), 10 to 55 Hz (Complies with the test method specified in JIS C0040 (1999).)
Display
Ambient conditions
0 to 10 VDC (10 k), 4 to 20 mA (250 ), frequency setting volume (selectable), RS485 Modbus
FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), JG (jogging), DB (external DC injection braking), SET (2nd function), 2CH (2-step acceleration/deceleration), FRS (free run), EXT (external trip), USP (USP function), SFT (soft lock), AT
(analog current input function selection), RS (reset), PTC (thermistor input), STA (3-wire startup), STP (3-wire stop), F/R (3wire forward/reverse), PID (PID selection), PIDC (PID integral reset), UP (UP of UP/DWN function), DWN (DWN of UP/DWN
function), UDC (data clear of UP/DWN function), OPE (forced OPE mode), ADD (frequency addition), F-TM (forced terminal
block), RDY (operation ready), SP-SET (special setting), EMR (emergency shutoff)
RUN (signal during operation), FA1 (frequency arrival signal 1), FA2 (frequency arrival signal 2), OL (overload warning signal), OD (PID excess deviation signal), AL (alarm signal), DC (analog input disconnection detection signal), FBV (PID FB
status output), NDc (network error), LOG (logical operation result), ODc (communication option disconnected), LOC (light
load signal)
AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging
operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape acceleration/
deceleration, electronic thermal characteristics/level adjustment, retry function, simplified torque boost, trip monitor, soft lock
function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/DOWN, overcurrent
suppression function
2 analogue inputs 0 to 10 V (20 k), 4 to 20 mA (250 )
Inputs signals
8
Specifications
Frequency inverters
Dimensions
IP 20 type 0.2 to 7.5 kW
Figure 1
Figure 2
W
W1
5
6
W
W1
5
6
H1
H
H1
H
t1
5
Voltage class
Single-phase
200 V
Three-phase
200 V
Three-phase
400 V
5
D1
1.9
t1
D1
D
1.9
Max. applicable
motor output kW
Inverter model
3G3JX@
0.2
AB002
0.4
AB004
Figure
Dimensions in mm
W1
1
1
0.75
AB007
2
1.5
AB015
2
2.2
AB022
2
0.2
A2002
1
0.4
A2004
1
0.75
A2007
1
1.5
A2015
2
2.2
A2022
2
3.7
A2037
2
5.5
A2055
2
7.5
A2075
2
0.4
A4004
2
0.75
A4007
2
1.5
A4015
2
2.2
A4022
2
4.0
A4040
2
5.5
A4055
2
7.5
A4075
2
D
H1
W
H
67
143
80
155
98
176
110
189
D
t1
D1
95.5
109.5
2.6
130.5
6
143
80
155
109.5
0.9
55
95.5
67
0.8
27
28
157.5
2.6
132.5
Weight
13
1.5
2.3
2.4
13
0.8
27
0.9
50
1.1
2.2
98
176
110
189
157.5
6
55
164
235
180
250
167.5
1.6
77.5
4.2
130.5
2.6
28
1.5
2.4
2.3
98
164
176
110
189
250
157.5
6
55
167.5
1.6
77.5
2.4
235
180
4.2
W
H
L
X
Y
M
Weight
kg
AX-FIJ1006-RE
81
40
193
183
57
M4
0.5
AX-FIJ1010-RE
112
47
226
216
88
M4
0.6
AX-FIJ1026-RE
112
47
226
216
88
M4
0.8
AX-FIJ2006-RE
81
50
193
183
57
M4
1.0
Rasmi footprint Filters
Filter only needed by the 1-phase 200 V or 3-phase 400 V to comply with C1 EMC class.
Rasmi model
1x200 V
3x200 V
3x400 V
JX
Dimensions
AX-FIJ2020-RE
112
50
226
216
88
M4
1.3
AX-FIJ2040-RE
182
55
289
279
150
M5
2.3
AX-FIJ3005-RE
112
45
226
216
88
M4
0.9
AX-FIJ3011-RE
112
45
226
216
88
M4
1.1
AX-FIJ3020-RE
182
45
289
279
150
M4
1.7
9
Input AC Reactor
Voltage
200 V
400 V
Reference
A
120
120
180
120
120
120
AX-RAI02800080-DE
AX-RAI00880175-DE
AX-RAI00350335-DE
AX-RAI07700042-DE
AX-RAI03500090-DE
AX-RAI01300170-DE
B2
70
80
85
70
80
80
Dimensions
C2
D
120 80
120 80
190 140
120 80
120 80
120 80
E
52
62
55
52
62
62
F
5.5
5.5
6
5.5
5.5
5.5
Weight
kg
1.78
2.35
5.5
1.78
2.35
2.50
DC Reactor
Voltage
Reference
200 V
AX-RC21400016-DE
AX-RC10700032-DE
AX-RC06750061-DE
AX-RC03510093-DE
AX-RC02510138-DE
A
AX-RC01600223-DE
AX-RC01110309-DE
AX-RC00840437-DE
AX-RC43000020-DE
400 V
AX-RC27000030-DE
AX-RC14000047-DE
AX-RC10100069-DE
AX-RC06400116-DE
AX-RC04410167-DE
AX-RC03350219-DE
B
C
Dimensions
D
E
F
G
H
96
84 113
105
Weight
kg
1.22
101 66
5
7.5
2
1.60
116
108 135 124 120 82 6.5
9.5
9.5
136
120 152
135 94 7
146
96
1.95
3.20
5.20
6.00
1.22
84 113 105 101 66
1.60
5
7.5
2
116
108 135 133 120 82 6.5
9.5
9.5
136
120 152
135 94 7
146
1.95
3.70
5.20
6.00
Output AC Reactor
Voltage
200 V
400 V
Reference
AX-RAO11500026-DE
AX-RAO07600042-DE
AX-RAO04100075-DE
AX-RAO03000105-DE
AX-RAO01830180-DE
AX-RAO01150220-DE
AX-RAO00950320-DE
AX-RAO16300038-DE
AX-RAO11800053-DE
AX-RAO07300080-DE
AX-RAO04600110-DE
AX-RAO03600160-DE
A
120
120
120
120
180
180
180
120
120
120
180
180
B2
70
70
80
80
85
85
85
70
80
80
85
85
Dimensions
C2
D
120 80
120 80
120 80
120 80
190 140
190 140
205 140
120 80
120 80
120 80
190 140
205 140
E
52
52
62
62
55
55
55
52
52
62
55
55
F
5.5
5.5
5.5
5.5
6
6
6
5.5
5.5
5.5
6
6
L
85
105
W
22
25
Dimensions
H
X
46
70
62
90
Y
-
m
5
5
Weight
kg
1.78
1.78
2.35
2.35
5.5
5.5
6.5
1.78
2.35
2.35
5.5
6.5
Chokes
X
Øm
W Y
L
H
10
Reference
D
diameter
Motor
KW
AX-FER2102-RE
AX-FER2515-RE
21
25
< 2.2
< 15
Weight
kg
0.1
0.2
Ød
Frequency inverters
Installation
Standard connections
3-phase 200 VAC
1-phase 200 VAC
3-phase 400 VAC
Inverter
R (L1)
U/T1
S (L2)
V/T2
T/N (L3)
W/T3
For Source logic
P24
4.7 k
5
Motor
Note:
To connect the DC reactor,
remove the short-circuit bar.
PD/+1
DC reactor
4
P/+
3
2
1
N/PCS
AL1
L
AL2
AL0
Frequency
meter
AM
H
Frequency
setting unit
1 to 2 k
11
10 VDC
Relay output
Common
RY
O
10 k
OI
L
Power supply input
4 to 20 mA DC
250
24 VDC
CM2
Terminal Block Specifications
Terminal
Name
Main circuit power supply input
R/L1, S/L2, T/N/L3
U/T1, V/T2, W/T3
PD/+1, P/+
P/+, N/-
JX
Inverter output
External DC reactor terminal
Function (signal level)
Used to connect line power to the drive.
Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal
S/L2 is not available for these units
Used to connect the motor
DC bus terminal
Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and
P/+2 when a DC reactor is connected.
-
Grounding
For grounding (grounding should conform to the local grounding code.)
11
Control Circuit
Type
Monitor
Signal
Digital output
signals
Analog input
signal
Digital
input
signals
Signal name
Function
Signal level
PCS
Input power supply
External power supply terminal for input signal (input)
...At sink logic
Internal power supply output terminal for input signal (output)
...At source logic
24 VDC ±10%
P24
Internal 24 VDC
24 VDC internal power supply
24 VDC±10% 100 mA
1
Multi-function Input selection 1
Factory setting: Forward/ Stop
2
Multi-function Input selection 2
Factory setting: Reverse/ Stop
3
Multi-function Input selection 3
Factory setting: Fault reset
4
Multi-function Input selection 4
Factory setting: Emergency stop fault
5
Multi-function Input selection 5
Factory setting: Multi-step speed reference 1
L
Multi-function Input selection common
--
H
Frequency reference power supply
10 VDC 10 mA max
O
Voltage frequency reference signal
0 to 10 VDC (10 K)
OI
Current frequency reference signal
4 to 20 mA (250 )
L
Frequency reference common
--
No.
AL2
NC output
AL1
NO output
AL0
Relay Output common
Factory default relay settings
Under normal operation:
AL2-AL0 Closed
Under abnormal operation or power shutdown: AL1-AL0 Open
250 VAC 2.5 A
30 VDC 3 A
250 VAC 1 A
30 VDC 1 A
Multi-function output terminal
Factory setting: Frequency arrival signal at a constant speed
CM2
Output signal common
--
AM
Analog frequency monitor/Analog output
current monitor
Factory setting: Analog frequency monitor
11
--
27 VDC
50 mA max
0 to 10 VDC 1 mA
Side by side mounting
12
Frequency inverters
Input AC Reactor
AC reactor
Power supply
3 phase 200 V class
Max. applicable
Current value
Reference
motor output kW
A
0.1 to 1.5
AX-RAI02800080-DE
8.0
2.2 to 3.7
AX-RAI00880175-DE
17.5
5.5 to 7.5
AX-RAI00350335-DE
33.5
MCCB
Inductance
mH
2.8
0.88
0.35
JX
U
X
R/L1
V
Y
S/L2
W
Z
T/L3
Max. applicable
motor output kW
0.4 to 1.5
2.2 to 4.0
5.5 to 7.5
400 V class
Current value
A
4.2
AX-RAI07700042-DE
AX-RAI03500090-DE
9.0
17.0
AX-RAI01300170-DE
Reference
Inductance
mH
7.7
3.5
1.3
DC Reactor
JX
Power
supply
MCCB
R/L1
S/L2
T/L3
+1
P/+2
DC reactor
Max. applicable
motor output kW
0.2
0.4
0.7
1.5
2.2
3.7
5.5
7.5
200 V class
Current value
A
AX-RC21400016-DE
1.6
AX-RC10700032-DE
3.2
AX-RC06750061-DE
6.1
AX-RC03510093-DE
9.3
AX-RC02510138-DE
13.8
AX-RC01600223-DE
22.3
AX-RC01110309-DE
30.9
AX-RC00840437-DE
43.7
Reference
Inductance
mH
21.4
10.7
6.75
3.51
2.51
1.60
1.11
0.84
Max. applicable
motor output kW
0.4
0.7
1.5
2.2
4.0
5.5
7.5
400 V class
Current value
A
2.0
AX-RC43000020-DE
AX-RC27000030-DE
3.0
4.7
AX-RC14000047-DE
AX-RC10100069-DE
6.9
AX-RC06400116-DE
11.6
AX-RC04410167-DE
16.7
AX-RC03350219-DE
21.9
Reference
Inductance
mH
43.0
27.0
14.0
10.1
6.40
4.41
3.35
Output AC Reactor
Max. applicable
motor output kW
0.1 to 0.4
0.75
1.5
2.2
3.7
5.5
7.5
JX
200 V class
Current value
A
AX-RAO11500026-DE
2.6
AX-RAO07600042-DE
4.2
AX-RAO04100075-DE
7.5
AX-RAO03000105-DE
10.5
AX-RAO01830160-DE
16.0
AX-RAO01150220-DE
22.0
AX-RAO00950320-DE
32.0
Reference
Inductance
mH
11.50
7.60
4.10
3.00
1.83
1.15
0.95
Max. applicable
motor output kW
0.4 to 1.5
2.2
4.0
5.5
7.5
400 V class
Current value
A
3.8
AX-RAO16300038-DE
AX-RAO11800053-DE
5.3
8.0
AX-RAO07300080-DE
AX-RAO04600110-DE
11.0
AX-RAO03600160-DE
16.0
Reference
Inductance
mH
16.30
11.80
7.30
4.60
3.60
-
13
Ordering information
Power
supply
D
B
MCCB
CX-Drive
CX-One
USB cable
A
AC reactor
A
B
B
LCD 5 lines remote
operator
Remote operator
extension cable
*
Filter
C
JX
C
C
A
A
Choke
DC reactor
C
A
Motor
Output reactor
Ground
* Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models
3G3JX
Specifications
Voltage class
Single-phase 200 V
Three-phase 200 V
Three-phase
400 V
14
Max. applicable motor output kW
Model
Rated output current (A)
Standard
0.2
1.4
3G3JX-AB002-EF
0.4
2.6
3G3JX-AB004-EF
0.75
4
3G3JX-AB007-EF
1.5
7.1
3G3JX-AB015-EF
2.2
10
3G3JX-AB022-EF
0.2
1.4
3G3JX-A2002-E
0.4
2.6
3G3JX-A2004-E
0.75
4
3G3JX-A2007-E
1.5
7.1
3G3JX-A2015-E
2.2
10
3G3JX-A2022-E
3.7
15.9
3G3JX-A2037-E
5.5
24
3G3JX-A2055-E
7.5
32
3G3JX-A2075-E
3G3JX-A4004-EF
0.4
1.5
0.75
2.5
3G3JX-A4007-EF
1.5
3.8
3G3JX-A4015-EF
2.2
5.5
3G3JX-A4022-EF
4.0
8.6
3G3JX-A4040-EF
5.5
13
3G3JXA4055-EF
7.5
16
3G3JXA4075-EF
Frequency inverters
A Line filters
Line filter Rasmi
Inverter
Voltage
Model 3G3JX-@
Reference
Rated current (A)
AB002 / AB004
AX-FIJ1006-RE
6
0.5
AB007
AX-FIJ1010-RE
10
0.6
0.8
1-Phase 200 VAC
3-Phase 200 VAC
Weight (kg)
AB015 / AB022
AX-FIJ1026-RE
26
A2002 / A2004 / A2007
AX-FIJ2006-RE
6
1.0
A2015 / A2022 / A2037
AX-FIJ2020-RE
20
1.3
2.3
A2055 / A2075
AX-FIJ2040-RE
40
A4004 / A4007 /A4015
AX-FIJ3005-RE
5
0.9
A4022 /A4040
AX-FIJ3011-RE
11
1.1
A4055 / A4075
AX-FIJ3020-RE
20
1.7
3-Phase 400 VAC
A Input AC Reactors
AC Reactor
Inverter
Voltage
3-Phase 200 VAC
Model 3G3JX-@
Reference
A2002 / A2004 / A2007
AX-RAI02800080-DE
A2015 / A2022 / A2037
AX-RAI00880175-DE
A2055 / A2075
AX-RAI00350335-DE
AB002 / AB004
1-Phase 200 VAC
AB007
Under development
AB015 / AB022
A4004 / A4007 / A4015
AX-RAI07700042-DE
A4022 / A4040
AX-RAI03500090-DE
A4055 / A4075
AX-RAI01300170-DE
3-Phase 400 VAC
A DC Reactors
200V 3-phase
200V single phase
DC Reactor
400V 3-phase
Inverter
DC Reactor
AX-RC10700032-DE
3G3JX-A2002
AX-RC21400016-DE
3G3JX-AB004
AX-RC06750061-DE
3G3JX-A2004
AX-RC10700032-DE
3G3JX-A4004
3G3JX-AB007
AX-RC03510093-DE
3G3JX-A2007
AX-RC06750061-DE
3G3JX-A4007
AX-RC27000030-DE
3G3JX-AB015
AX-RC02510138-DE
3G3JX-A2015
AX-RC03510093-DE
3G3JX-A4015
AX-RC14000047-DE
3G3JX-AB022
AX-RC01600223-DE
3G3JX-A2022
AX-RC02510138-DE
3G3JX-A4022
AX-RC10100069-DE
3G3JX-A2037
AX-RC01600223-DE
3G3JX-A4040
AX-RC06400116-DE
3G3JX-A2055
AX-RC01110309-DE
3G3JX-A4055
AX-RC04410167-DE
3G3JX-A2075
AX-RC00840437-DE
3G3JX-A4075
AX-RC03350219-DE
Inverter
3G3JX-AB002
-
A Chokes
DC Reactor
Inverter
-
AX-RC43000020-DE
B Accessories
Description
AX-FER2102-RE
21
For 2.2 KW motors or below
AX-FER2515-RE
25
For 7.5 KW motors or below
A Output AC Reactors
AC Reactor
Inverter
Voltage
Model 3G3JX-@
Reference
A2001 / A2002 / A2004
AB001 / AB002 / AB004
AX-RAO11500026-DE
A2007/AB007
AX-RAO07600042-DE
A2015 / AB015
AX-RAO04100075-DE
A2022 / AB022
AX-RAO03000105-DE
A2037
AX-RAO01830160-DE
A2055
AX-RAO01150220-DE
A2075
AX-RAO00950320-DE
A4004 / A4007 / A4015
AX-RAO16300038-DE
A4022
AX-RAO11800053-DE
A4040
AX-RAO07300080-DE
A4055
AX-RAO04600110-DE
A4075
AX-RAO03600160-DE
200 VAC
*1
Model
Functions
5 Line LCD remote operator
LCD remote
with copy function,
AX-OP05-E
operator
cable length max. 3m.*1
Remote operator 3 meters cable for connecting
3G3AX-CAJOP300-EE
cable
remote operator
LED remote
LED remote operator, cable
3G3AX-OP01
operator
length max. 3m
Mounting kit for Mounting kit for LED operator
4X-KITMINI
LED operator
on panel
3G3AX-PCACN2
USB converter /
RJ45 to USB connection
USB cable
cable
USB-convertercable
3G3AX-CTB020-EE
3G3AX-CTR150-EE
Description
RJ45 T-Branch
cable
RJ45 Terminator
resistor
T cable for RS-422
connection
Terminator resistor for
RS-422 connection
Please note, for 3G3JX inverters models, the operator will only display 2 lines
of text.
D Computer software
Types
Software
400 VAC
Types
Digital
operator
Diameter
Accessories
Model
Model
Description
Installation
CX-Drive
Computer
software
Configuration and monitoring
software tool
CX-One
Computer
software
Configuration and monitoring
software tool
€Saver
Computer
software
Software tool for Energy Saving calculation
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I110E-EN-02
JX
In the interest of product improvement, specifications are subject to change without notice.
15
OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 industrial.omron.eu
Austria
Tel: +43 (0) 2236 377 800
industrial.omron.at
Germany
Tel: +49 (0) 2173 680 00
industrial.omron.de
Portugal
Tel: +351 21 942 94 00
industrial.omron.pt
Turkey
Tel: +90 212 467 30 00
industrial.omron.com.tr
Belgium
Tel: +32 (0) 2 466 24 80
industrial.omron.be
Hungary
Tel: +36 1 399 30 50
industrial.omron.hu
Russia
Tel: +7 495 648 94 50
industrial.omron.ru
United Kingdom
Tel: +44 (0) 870 752 08 61
industrial.omron.co.uk
Czech Republic
Tel: +420 234 602 602
industrial.omron.cz
Italy
Tel: +39 02 326 81
industrial.omron.it
South Africa
Tel: +27 (0)11 579 2600
industrial.omron.co.za
Denmark
Tel: +45 43 44 00 11
industrial.omron.dk
Netherlands
Tel: +31 (0) 23 568 11 00
industrial.omron.nl
Spain
Tel: +34 913 777 900
industrial.omron.es
Finland
Tel: +358 (0) 207 464 200
industrial.omron.fi
Norway
Tel: +47 (0) 22 65 75 00
industrial.omron.no
Sweden
Tel: +46 (0) 8 632 35 00
industrial.omron.se
France
Tel: +33 (0) 1 56 63 70 00
industrial.omron.fr
Poland
Tel: +48 22 458 66 66
industrial.omron.pl
Switzerland
Tel: +41 (0) 41 748 13 13
industrial.omron.ch
More Omron representatives
industrial.omron.eu
Automation Systems
• Programmable logic controllers (PLC) • Human machine interfaces (HMI) • Remote I/O
• Industrial PC’s • Software
Motion & Drives
• Motion controllers • Servo systems • Inverters • Robots
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors
• Cable connectors • Displacement & width-measuring sensors • Vision systems
• Safety networks • Safety sensors • Safety units/relay units • Safety door/guard lock switches
KPP_JX_EN_INT03
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant
or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
3G3AX-RAI02800080-DE