3G3JXA2055

3G3JXA2055

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    New AC Drives Family Delivers Excellent Performance And Value

  • 数据手册
  • 价格&库存
3G3JXA2055 数据手册
3G3JX AC DRIVES Compact and complete » »Q u a l i t y & r e l i a b i l i t y y o u c a n d e p e n d o n » »Co m m u n i c a t i o n s b u i l t- i n » » Co s t a n d e c o - f r i e n d l y The smallest gets integrated... Key features include: • Ratings • RS485 Modbus built-in Omron fully understands your needs, which is why we put quality and reliability first. And we keep listening, so our products come with features and functionality to save you time and money. • Side-by-side With the RFI filter built-in and communications integrated as standard, the 3G3JX provides a compact and complete solution to a whole range of simple applications, such as conveyor control. • Emergency • EMC • PID filter built-in • Micro-surge • Automatic • Second • Auto • PTC mounting function voltage suppression energy saving shut-off motor setting carrier-frequency reduction thermistor input • Cooling • RoHS 2 up to 7.5 kW (10 HP) fan switch control Compliant Level (dBV) OMRON Function Block for Pulse Output Positioning. OMRON Function Block for Communications. 120 110 100 90 80 70 60 50 40 30 20 10 0 No Filter Integrated EMC filter 150 200 500k 1M 2M Conducted emission data 5M 10M 20M 30M Frequency (Hz) Easy network integration Easy communications setting Space and cost saving The RS485 Modbus is built into the RJ45 Modbus commands are implemented The new 3G3JX has a built-in EMC filter port in the inverter front, making it very even in low end CP1 PLC family by that saves on costs and space compared easy to add inverters into the network Modbus-RTU Easy Master functionality, with the standard external filter solution. without any extra option boards. making it easier than ever to integrate the Therefore, saving money and space. inverters into the network. 1 ph : EN61800-3 cat. C1 3 ph : EN61800-3 cat. C2 3 Everything on-board for your application ~ Sensor Emergency stop switch Power supply circuit IGBT gate Motor Sensor? 24 V Latch Set EMR Reset RS Interruption PCS 0V M Heating section No additional devices required Convenient and efficient Reliable emergency shutdown Even advanced functionality such as PID The parameter settings of two different The IGBT’s output is directly switched off control is standard with the 3G3JX motors can be stored, allowing the from the external input, assuring no inverter making it a convenient solution inverter to drive different motors with a energy is supplied to the motor. This for applications such as pumps & fans unique inverter. The two motors are never hardware-based solution is more reliable where pressure, flow and other processes working at the same time. than other CPU dependent solutions. need controlling. 4 Spikes in the terminal voltage are suppressed even when the wiring distance from the inverter to the motor is long Power (%) 1,250 V 90 80 70 60 50 40 30 20 10 0 91% Damper system 76% 61% Energy-saving effect 22% Inverter system 10 20 30 40 50 60 70 80 90 100 Airflow (%) Silent operation Maximize motor life Automatic energy saving Depending on the inverter temperature, Advanced PWM control is used to The Inverter always adopts the optimum switching off the fan creates a noise-free suppress micro-surge voltages that energy-saving setting for cost savings in atmosphere and prolongs the life time of sometimes cause malfunction in such applications as fans and pumps. the product. 460 V motors. The motor is thus The inverter can reduce energy protected and its life is prolonged. consumption by 61% compared with standard mechanical systems. Reliability with environmental responsibility Omron is renowned for the reliability of its products. Moreover, Omron’s policy is to offer environmentally safe products free from any banned substances. 5 3G3JX Compact & Complete • V/f controlled AC Drive • Side by side mounting • Built-in EMC filter • Built-in RS-485 Modbus • Overload detection function (150% during 60s) • PID • Micro-surge voltage suppression • Automatic energy saving • Emergency shut-off • Second motor setting • Auto carrier-frequency reduction • PTC thermistor input • Cooling fan switch control • PC configuration tool: CX-Drive • CE, UL, cUL, RoHS Ratings • 200 V Class single-phase, 0.2 to 2.2 kW (1/4 to 3 HP) • 200 V Class three-phase, 0.2 to 7.5 kW (1/4 to 10 HP) • 400 V Class three-phase, 0.4 to 7.5 kW (1/2 to 10 HP) System Configuration Power Supply RJ45 - USB Cable Software: CX-Drive in CX-One MCCB Remote Operator Extansion Cable AC Reactor Filter Remote Operator with 2-line LCD display * CP1 PLC 3G3JX DC Reactor Choke Motor Output Reactor Ground * Only needed for 3 phase 200V or to comply C1 on 3 phase 400V models 6 Frequency Inverters Specifications Type Designation 3G3JXAE002 3G3JX series A: Standard specs Max. applicable motor output 002: 0.2 kW (1/4 HP) to 075: 7.5 kW (10 HP) Voltage: E: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC Single-phase 3G3JX-9 AE007 AE015 AE022 – – – A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 HP 1/4 1/2 200 V 0.4 0.9 1.3 2.4 3.4 5.5 8.3 11.0 240 V 0.5 1.0 1.6 2.9 4.1 6.6 9.9 13.3 1.4 2.6 4 7.1 10 15.9 24 32 Inverter capacity kVA Output characteristics AE004 kW Three-phase 3G3JX-9 Applicable motor capacity1 AE002 Rated output current (A) 1 Max. output voltage 2 7 1/2 10 400 Hz Rated input voltage and frequency Rated input current (A) Single-phase 200 to 240 V 50/60 Hz 3-phase 200 to 240 V 50/60 Hz 1.8 3.4 5.2 9.3 Allowable voltage fluctuation 13.0 20.0 30.0 40.0 -15% to +10% Allowable frequency fluctuation +5% Built-in filter Braking torque 5 Proportional to input voltage: 0 to 240 V Max. output frequency Power supply 3 EMC filter (C1 single phase) At short-time deceleration At capacitor feedback 50% for 3-phase 20 to 40% for 1-phase Approx. 50% Cooling method Approx 20% to 40% Self cooling Approx 20% Forced-air-cooling Note: 1. Based on a standard 3-Phase standard motor. 400 V class A4004 A4007 A4015 A4022 A4037 kW 0.4 0.75 1.5 2.2 3.7 HP 1/2 Three-phase 3G3JX-9 Applicable motor capacity1 Inverter capacity kVA Output characteristics 1 2 5.5 7.5 7 1/2 10 0.9 1.6 2.5 3.6 5.6 8.5 10.5 480 V 1.2 2.0 3.1 4.5 7.1 10.8 13.3 1.5 2.5 3.8 5.5 8.6 13.0 16.0 16.5 20.0 Rated output current (A) Proportional to input voltage: 0 to 480 V Max. output frequency 400 Hz Rated input voltage and frequency Rated input current (A) 3-phase 380 to 480 V 50/60 Hz 2.0 3.3 Allowable voltage fluctuation 5.0 7.0 11.0 -15% to +10% Allowable frequency fluctuation +5% Built-in filter Braking torque 5 A4075 380 V Max. output voltage Power supply 3 A4055 EMC filter C2 class At short-time deceleration At capacitor feedback Cooling method Approx. 50% Self cooling Approx 20% to 40% Approx 20% Forced-air-cooling Note: 1. Based on a standard 3-Phase standard motor. 3G3JX 7 Specifications Common specifications Model number 3G3JX-9 Phase-to-phase sinusoidal modulation PWM (V/f) Output frequency range 0.5 to 400 Hz Frequency precision Control functions Resolution of frequency set value 8 Analog set value: ±0.4% of the max. frequency (25 ±10ºC) Digital set value: 0.1 Hz Analog set value: 1/1000 of maximum frequency 0.1 Hz Overload capability 150% rated output current for one minute Frequency set value 0 to 10 VDC (10KΩ), 4 to 20mA (250Ω), frequency setting volume (selectable), RS485 Modbus V/f Characteristics Constant/ reduced torque Inputs signals FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), JG (jogging), DB (external DC injection braking), SET (2nd function), 2CH (2-step acceleration/deceleration), FRS (free run), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input function selection), RS (reset), PTC (thermistor input), STA (3-wire startup), STP (3-wire stop), F/R (3wire forward/reverse), PID (PID selection), PIDC (PID integral reset), UP (UP of UP/DWN function), DWN (DWN of UP/DWN function), UDC (data clear of UP/DWN function), OPE (forced OPE mode), ADD (frequency addition), F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting), EMR (emergency shutoff) Output signals RUN (signal during operation), FA1 (frequency arrival signal 1), FA2 (frequency arrival signal 2), OL (overload warning signal), OD (PID excess deviation signal), AL (alarm signal), DC (analog input disconnection detection signal), FBV (PID FB status output), NDc (network error), LOG (logical operation result), ODc (communication option disconnected), LOC (light load signal) Standard functions AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape acceleration/ deceleration, electronic thermal characteristics/level adjustment, retry function, simplified torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/DOWN, overcurrent suppression function Analog inputs 2 analog inputs 0 to 10V (20KΩ), 4 to 20mA (250Ω) Accel/Decel times 0.01 to 3000s (line/curve selection), 2nd accel/decel setting available Display Ambient conditions Digital set value: ±0.01% of the max. frequency Resolution of output frequency Functionality Protection functions Specifications Control methods Status indicator LED’s Run, Program, Power, Alarm, Power, Hz, Amps, Volume Led indicator Digital operator: Available to monitor frequency reference, output current, output frequency Motor overload protection Electronic Thermal overload relay and PTC thermistor input Instantaneous overcurrent 180% of rated current Overload 150% for 1 minute Overvoltage 790V for 400V type and 395V for 200V type Momentary power loss Following items are selectable: Alarm, 0 Hz start, frequency output at interruption, maximum frequency Cooling fin overheat Temperature monitor and error detection Stall prevention level Selectable level applicable only at constant speed or during acceleration and constant speed Ground fault Detected at power-on Power charge indication On when power is supplied to the control part Degree of protection IP20 Ambient humidity 90% RH or less (without condensation) Storage temperature -20ºC to +65ºC (short-term temperature during transportation) Ambient temperature -10°C to 50°C (Both the carrier frequency and output current need to be reduced at over 40°C.) Installation Indoor (no corrosive gas, dust, etc.) Installation height Max. 1000 m Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz (Complies with the test method specified in JIS C0040 (1999).) Frequency Inverters Dimensions Unit: mm Figure 1 Figure 2 W W1 5 6 W W1 5 6 H1 H H1 H t1 5 Voltage class Single-phase 200 V Three-phase 200 V Three-phase 400 V 5 D1 Max. applicable motor output 1.9 Inverter model Figure 1/4 HP 3G3JX-AE002 1 1/2 HP 3G3JX-AE004 1 1 HP 2 HP 3G3JX-AE007 3G3JX-AE015 2 2 2.2 kW 3 HP 3G3JX-AE022 2 0.2 kW 1/4 HP 3G3JX-A2002 1 0.4 kW 0.75 kW 1.5 kW 2.2 kW 3.7 kW 5.5 kW 7.5 kW 1/2 HP 1 HP 2 HP 3 HP 5 HP 7 1/2 HP 10 HP 3G3JX-A2004 3G3JX-A2007 3G3JX-A2015 3G3JX-A2022 3G3JX-A2037 3G3JX-A2055 3G3JX-A2075 1 1 2 2 2 2 2 0.4 kW 1/2 HP 3G3JX-A4004 2 0.75 kW 1.5 kW 2.2 kW 3.7 kW 5.5 kW 1 HP 2 HP 3 HP 5 HP 7 1/2 HP 3G3JX-A4007 3G3JX-A4015 3G3JX-A4022 3G3JX-A4037 3G3JX-A4055 2 2 2 2 2 7.5 kW 10 HP 3G3JX-A4075 2 kW HP 0.2 kW 0.4 kW 0.75 kW 1.5 kW t1 D1 D 1.9 D Dimensions (Unit: mm) W1 H1 W H 67 143 80 155 D t1 95.5 109.5 2.6 130.5 98 176 110 189 157.5 6 95.5 D1 Weight (kg) 13 0.8 27 0.9 28 1.5 2.3 55 2.4 13 0.8 0.9 1.1 2.2 67 143 80 155 109.5 132.5 2.6 27 50 98 176 110 189 157.5 6 66 164 235 180 250 167.5 1.6 77.5 4.2 130.5 2.6 28 1.5 2.4 2.3 98 176 164 235 110 180 189 250 1.57.5 6 55 167.5 1.6 77.5 2.4 4.2 Line Filters, Footprint Type Rasmi line filter model 1x200 V 3x200 V 3x400 V Dimensions (Unit: mm) W H L X Y M Weight (kg) 3G3AX-FIJ1006-RE 81 40 193 183 57 M4 0.5 3G3AX-FIJ1010-RE 112 47 226 216 88 M4 0.6 3G3AX-FIJ1026-RE 3G3AX-FIJ2006-RE 112 81 47 50 226 193 216 183 88 57 M4 M4 0.8 1.0 3G3AX-FIJ2020-RE 112 50 226 216 88 M4 1.3 3G3AX-FIJ2040-RE 182 55 289 279 150 M5 2.3 3G3AX-FIJ3005-RE 3G3AX-FIJ3011-RE 3G3AX-FIJ3020-RE 112 112 182 45 45 45 226 226 289 216 216 279 88 88 150 M4 M4 M4 0.9 1.1 1.7 Note: Filter only needed by the 1-phase 200V or 3-phase 400V to comply with C1 EMC class. 3G3JX 9 Dimensions Unit: mm Input AC Reactor Dimensions (Unit: mm) Voltage class Model 3G3AX-9 RAI02800080-DE 120 70 120 80 52 5.5 1.78 200 V RAI00880175-DE 120 80 120 80 62 5.5 2.35 400 V A B2 C2 D E F Weight (kg) RAI00350335-DE 180 85 190 140 55 6 5.5 RAI07700042-DE 120 70 120 80 52 5.5 1.78 RAI03500090-DE RAI01300170-DE 120 120 80 80 120 120 80 80 62 62 5.5 5.5 2.35 2.50 DC Reactor Voltage class Model 3G3AX-9 Dimensions (Unit: mm) A B C RC21400016-DE RC06750061-DE RC03510093-DE RC02510138-DE RC01600223-DE RC01110309-DE RC00840437-DE 84 113 400 V F G Weight (kg) H 108 135 120 152 1.22 101 105 116 124 136 146 RC43000020-DE RC27000030-DE RC14000047-DE RC10100069-DE RC06400116-DE RC04410167-DE RC03350219-DE E 96 RC10700032-DE 200 V D 66 5 120 82 6.5 135 94 7 7.5 2 1.60 1.95 3.20 5.20 6.00 9.5 9.5 – 96 84 113 108 135 120 152 1.22 101 105 116 133 136 146 66 5 120 82 6.5 135 94 7 7.5 2 1.60 1.95 3.70 5.20 6.00 9.5 9.5 – Output AC Reactor Voltage class 200 V 400 V Model 3G3AX-9 Dimensions (Unit: mm) A B2 C2 D E F Weight (kg) RAO11500026-DE 120 70 120 80 52 5.5 1.78 RAO07600042-DE 120 70 120 80 52 5.5 1.78 RAO04100075-DE RAO03000105-DE 120 120 80 80 120 120 80 80 62 62 5.5 5.5 2.35 2.35 RAO01830180-DE 180 85 190 140 55 6 5.5 RAO01150220-DE RAO00950320-DE RAO16300038-DE RAO11800053-DE RAO07300080-DE RAO04600110-DE RAO03600160-DE 180 180 120 120 120 180 180 85 85 70 80 80 85 85 190 205 120 120 120 190 205 140 140 80 80 80 140 140 55 55 52 52 62 55 55 6 6 5.5 5.5 5.5 6 6 5.5 6.5 1.78 2.35 2.35 5.5 6.5 X Øm W Y Chokes Model 3G3AX-9 10 L Diameter d Motor Rating Dimensions (Unit: mm) L W H X Y m Weight (kg) FER2102-RE 21 < 2.2 kW (3 HP) 85 22 46 70 – 5 0.1 FER2515-RE 25 < 7.5 kW (10 HP) 105 25 62 90 – 5 0.2 H Ød Frequency Inverters Standard Connections Regenerative braking unit DC reactor (optional) +1 P/+2 R/L1 (L1) *1 3-phase 200 V AC 1/3-phase 200 V AC *2 3-phase 400 V AC Multi-function input 1 Multi-function input 2 Multi-function input 3 Multi-function input 4 Multi-function input 5 Sequence input common Frequency reference power supply Frequency reference (1 to 2 kΩ) Frequency reference input (voltage) Frequency reference common Frequency reference input (current) N/U/T1 S/L2 (L2) V/T2 T/L3 (N/L3) W/T3 M P24 PSC S1 S2 S3 MB MA MC Relay output *3 Common S4 S5 SC FS P1 Multi-function output PC Multi-function output common AM Analog monitor output FV FC FI *1. The items in parentheses indicate terminal symbols for 3G3JX-AE . *2. Connect a single-phase 200-V AC input to terminals L1 and N/L3. *3. By factory default, MA is set to NC contact, and MB to NO contact in the relay output (MA, MB) contact selection (C036). Main Circuit Terminals Terminal symbol Terminal name Function R/L1, S/L2, T/L3* Main power supply input terminal Connect the input power supply. U/T1, V/T2, W/T3 Inverter output terminal Connect to the motor. +1, P/+2 External DC reactor terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/+2 when a DC reactor is connected. P/+2, N/- Regenerative braking unit connection terminal Connect optional regenerative braking units. (If a braking torque is required) Connection example Motor ELB Power supply Ground terminal Ground (Connect to ground to prevent electric shock and reduce noise.) Do not remove the short-circuit bar between +1 and P/+2 when a DC reactor is not connected. Note: *For 3G3JX-AE999's terminal symbols, R/L1 corresponds to L1, S/L2 to L2, and T/L3 to N/L3. Connect a single-phase 200-V AC input to terminals L1 and N/L3. 3G3JX 11 Control Circuit Terminals Terminal symbol PSC Terminal name and function Default setting Note External power supply terminal for input signal (input) ...At sink logic Internal power supply output terminal for input signal (output) ...At source logic – 24 V DC ±10% 30 mA max. Forward/Stop Contact input Reverse/Stop Close: ON (Start) Fault reset Open: OFF (Stop) S1 S2 Input signal S3 S4 Multi-function input terminals S1 to S5 Select 5 functions among the 31 functions and allocate them to from terminals S1 to S5. The terminal allocation is changed automatically when the emergency shutoff function is used. Emergency stop fault Minimum ON time: 12 ms min. S5 Monitor signal Frequency reference input Multi-step speed reference 1 SC Input signal common – AM Analog frequency monitor/Analog output current monitor Analog frequency monitor FS Frequency reference power supply – FV Voltage frequency reference signal – 10 V DC, 10 mA max. FI Current frequency reference signal – 0 to 10 V DC; Input impedance 10 kΩ; When installing variable resistors at FS, FV, and FC (1 to 2 kΩ) FC Frequency reference common – 4 to 20 mA DC; Input impedance 250 Ω P1 Multi-function output terminal; Select the status of the Inverter and allocate it to terminal P1. Frequency arrival signal at a constant speed PC Output signal common – MA Factory default relay settings Output terminal MB Under normal operation: MA-MC Closed Output signal 27 V DC; 50 mA max. Contact capacity Resistance load Inductive load Max. AC250V 2.5A, DC30V 3A AC250V 0.2A, DC30V 0.7A Min. AC100V 10mA, DC5V 100mA Max. AC250V 1A, DC30V 1A Min. AC100V 10mA, DC5V 100mA MA-MC Relay output signal Under abnormal operation or power shutdown: MA-MC Open MC MB MA MC AC250V 0.2A, DC30V 0.2A MB-MC Side by side mounting 12 Frequency Inverters Reactors Input AC Reactor 3-phase 200 V class 3-phase 400 V class Max. applicable motor output Model 3G3AX-9 Current value Inductance mH Max. applicable motor output Model 3G3AX-9 Current value Inductance mH 0.1 to 1.5 kW (1/8 to 2 HP) RAI02800080-DE 2.2 to 3.7 kW (3 to 5 HP) RAI00880175-DE 8.0 A 2.8 0.4 to 1.5 kW (1/2 to 2 HP) RAI07700042-DE 4.2 A 7.7 17.5 A 0.88 2.2 to 3.7 kW (3 to 5 HP) RAI03500090-DE 9.0 A 5.5 to 7.5 kW (7 1/2 to 10 HP) RAI00350335-DE 33.5 A 3.5 0.35 5.5 to 7.5 kW (7 1/2 to 10 HP) RAI01300170-DE 17.0 A 1.3 Current value Inductance AC reactor Power supply MCCB 3G3JX U X R/L1 V Y S/L2 W Z T/L3 DC Reactor 3-phase 200 V class 3-phase 400 V class Max. applicable motor output Model 3G3AX-9 Current value Inductance Max. applicable motor output Model 3G3AX-9 0.2 kW (1/4 HP) RC21400016-DE 1.6 A 21.4 – – – – 0.4 kW (1/2 HP) RC10700032-DE 3.2 A 10.7 0.4 kW (1/2 HP) RC43000020-DE 2.0 A 43 0.75 kW (1 HP) RC06750061-DE 6.1 A 6.75 0.75 kW (1 HP) RC27000030-DE 3.0 A 27 1.5 kW (2 HP) RC03510093-DE 9.3 A 3.51 1.5 kW (2 HP) RC14000047-DE 4.7 A 14 2.2 kW (3 HP) RC02510138-DE 13.8 A 2.51 2.2 kW (3 HP) RC10100069-DE 6.9 A 10.1 3.7 kW (5 HP) RC01600223-DE 22.3 A 1.6 3.7 kW (5 HP) RC06400116-DE 11.6 A 6.4 5.5 kW (7 1/2 HP) RC01110309-DE 30.9 A 1.11 5.5 kW (7 1/2 HP) RC04410167-DE 16.7 A 4.41 7.5 kW (10 HP) RC00840437-DE 43.7 A 0.84 7.5 kW (10 HP) RC03350219-DE 21.9 A 3.35 3G3JX Power supply MCCB R/L1 S/L2 T/L3 +1 P/+2 DC reactor Output AC Reactor 3-phase 200 V class 3-phase 400 V class Max. applicable motor output Model 3G3AX-9 Current value Inductance Max. applicable motor output Model 3G3AX-9 Current value Inductance 0.1 to 0.4 kW (1/8 to 1/2 HP) RAO11500026-DE 2.6 A 11.5 0.4 to 1.5 kW (1/2 to 2 HP) RAO16300038-DE 3.8 A 16.3 0.75 kW (1 HP) RAO07600042-DE 4.2 A 7.6 2.2 kW (3 HP) RAO11800053-DE 5.3 A 11.8 1.5 kW (2 HP) RAO04100075-DE 7.5 A 4.1 3.7 kW (5 HP) RAO07300080-DE 8A 7.3 2.2 kW (3 HP) RAO03000105-DE 10.5 A 3 5.5 kW (7 1/2 HP) RAO04600110-DE 11 A 4.6 3.7 kW (5 HP) RAO01830160-DE 16 A 1.83 7.5 kW (10 HP) RAO03600160-DE 16 A 3.6 5.5 kW (7 1/2 HP) RAO01150220-DE 22 A 1.15 7.5 kW (10 HP) RAO00950320-DE 32 A 0.95 3G3JX 13 Ordering Information Power Supply USB Cable Software: CX-Drive in CX-One MCCB Remote Operator Extansion Cable AC Reactor Remote Operator with 5-line LCD display * Filter CP1 PLC 3G3JX DC Reactor Choke Output Reactor Motor Ground * Only needed for 3 phase 200V or to comply C1 on 3 phase 400V models 3G3JX AC Drives Specifications Voltage class Single-phase 200 V Three-phase 200 V Three-phase 400 V Model Max. applicable motor output Rated output current Standard 0.2 kW (1/4 HP) 1.4 A 3G3JX-AE002 0.4 kW (1/2 HP) 2.6 A 3G3JX-AE004 0.75 kW (1 HP) 4A 3G3JX-AE007 1.5 kW (2 HP) 7.1 A 3G3JX-AE015 2.2 kW (3 HP) 10 A 3G3JX-AE022 0.2 kW (1/4 HP) 1.4 A 3G3JX-A2002 0.4 kW (1/2 HP) 2.6 A 3G3JX-A2004 0.75 kW (1 HP) 4A 3G3JX-A2007 1.5 kW (2 HP) 7.1 A 3G3JX-A2015 2.2 kW (3 HP) 10 A 3G3JX-A2022 3.7 kW (5 HP 15.9 A 3G3JX-A2037 5.5 kW (7 1/2 HP) 24 A 3G3JX-A2055 7.5 kW (10 HP) 32 A 3G3JX-A2075 0.4 kW (1/2 HP) 1.5 A 3G3JX-A4004 0.75 kW (1 HP) 2.5 A 3G3JX-A4007 1.5 kW (2 HP) 3.8 A 3G3JX-A4015 2.2 kW (3 HP) 5.5 A 3G3JX-A4022 3.7 kW (5 HP) 8.6 A 3G3JX-A4037 5.5 kW (7 1/2 HP) 13 A 3G3JX-A4055 7.5 kW (10 HP) 16 A 3G3JX-A4075 Line Filters Inverter Voltage 1-phase 200 VAC 3-phase 200 VAC 3-phase 400 VAC 14 Line filter Rasmi Model 3G3JX-9 Model 3G3AX-9 Rated current (A) Weight (kg) AE002 / AE004 FIJ1006-RE 6 0.5 AE007 FIJ1010-RE 10 0.6 0.8 AE015 / AE022 FIJ1026-RE 26 A2002 / A2004 / A2007 FIJ2006-RE 6 1 A2015 / A2022 / A2037 FIJ2020-RE 20 1.3 A2055 / A2075 FIJ2040-RE 40 2.3 A4004 / A4007 /A4015 FIJ3005-RE 5 0.9 A4022 /A4037 FIJ3011-RE 11 1.1 A4055 / A4075 FIJ3020-RE 20 1.7 Frequency Inverters Ordering Information Input AC Reactors Inverter Voltage 3-phase 200 VAC AC Reactor Model 3G3JX-9 Model 3G3AX-9 A2002 / A2004 / A2007 RAI02800080-DE A2015 / A2022 / A2037 RAI00880175-DE A2055 / A2075 RAI00350335-DE A4004 / A4007 / A4015 RAI07700042-DE A4022 / A4037 RAI03500090-DE A4055 / A4075 RAI01300170-DE 3-phase 400 VAC DC Reactors 1-phase 200 VAC 3-phase 200 VAC 3-phase 400 VAC Inverter DC Reactor Inverter DC Reactor Inverter DC Reactor 3G3JX-AB002 3G3AX-RC10700032-DE 3G3JX-A2002 3G3AX-RC21400016-DE - - 3G3JX-AB004 3G3AX-RC06750061-DE 3G3JX-A2004 3G3AX-RC10700032-DE 3G3JX-A4004 3G3AX-RC43000020-DE 3G3JX-AB007 3G3AX-RC03510093-DE 3G3JX-A2007 3G3AX-RC06750061-DE 3G3JX-A4007 3G3AX-RC27000030-DE 3G3JX-AB015 3G3AX-RC02510138-DE 3G3JX-A2015 3G3AX-RC03510093-DE 3G3JX-A4015 3G3AX-RC14000047-DE 3G3JX-AB022 3G3AX-RC01600223-DE 3G3JX-A2022 3G3AX-RC02510138-DE 3G3JX-A4022 3G3AX-RC10100069-DE - - 3G3JX-A2037 3G3AX-RC01600223-DE 3G3JX-A4037 3G3AX-RC06400116-DE - - 3G3JX-A2055 3G3AX-RC01110309-DE 3G3JX-A4055 3G3AX-RC04410167-DE - - 3G3JX-A2075 3G3AX-RC00840437-DE 3G3JX-A4075 3G3AX-RC03350219-DE Chokes Accessories Diameter (mm) Description 3G3AX-FER2102-RE 21 For 2.2 kW (3 HP) motors or below 3G3AX-FER2515-RE 25 For 7.5 kW (10 HP) motors or below Digital operator Model Types 200 VAC 400 VAC AC Reactor Model 3G3JX-9 Model 3G3AX-9 A2002 / A2004 / AE002 / AE004 RAO11500026-DE A2007 / AE007 RAO07600042-DE A2015 / AE015 RAO04100075-DE A2022 / AE022 RAO03000105-DE A2037 RAO01830160-DE A2055 RAO01150220-DE A2075 RAO00950320-DE A4004 / A4007 / A4015 RAO16300038-DE A4022 RAO11800053-DE A4037 RAO07300080-DE A4055 RAO04600110-DE A4075 RAO03600160-DE Accessories Inverter Description 3G3AX-OP05 LCD remote operator 3G3AX-CAJOP300-EE Output AC Reactor Voltage Model 3G3AX-CONV1 Functions 2 Line LCD remote operator with copy function, cable length max. 3m. Remote operator 3 meters cable for concable necting remote operator USB converter / USB cable RJ45 to USB connection cable Computer Software Item Description Functions CX-Drive Set, transfer and compare parameters; perform test runs and adjustment; AC Drive/Servo perform monitoring and data tracing for Programming software Omron inverters and servos included in CX-One software. CX-One All-in-one Automation software Program, configure and simulate operations for PLCs, HMIs, networks, motion control systems, temperature and process controllers. Note: Software runs on the following OS: Windows 2000 (Service Pack 3a or higher), XP, Vista or Windows 7. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Specifications are subject to change without notice. 3G3JX 15 OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br Omron Europe B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • Tel: +31 (0) 23 568 13 00 • Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu Authorized Distributor: Automation Control Systems • Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders Temperature & Process Controllers • Single and Multi-loop Controllers Sensors & Vision • Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors • Amplified Photomicrosensors • Measurement Sensors • Ultrasonic Sensors • Vision Sensors • RFID/Code Readers Industrial Components • Relays • Pushbuttons & Indicators • Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches I30I-E-02 Note: Specifications are subject to change. © 2013 Omron Electronics LLC Printed on recycled paper. Printed in U.S.A.
3G3JXA2055 价格&库存

很抱歉,暂时无法提供与“3G3JXA2055”相匹配的价格&库存,您可以联系我们找货

免费人工找货