RX frequency inverter Customised to your machine • • • • • • • • • • • Up to 132 kW High starting torque in open loop: 200% at 0.3Hz Full torque at 0 Hz in closed loop Sensor-less and vector closed-loop control Double rating VT 120%/1 min and CT 150%/1 min Built-in EMC filter Built-in application functionality Indexer functionality Automatic energy saving Micro-surge voltage suppression CE, cULus, RoHS Ratings • 200 V Class three-phase 0.4 to 55 kW • 400 V Class three-phase 0.4 to 132 kW System configuration Power supply RJ45 - USB cable MCCB Software + + Input AC reactor Digital operator options Digital operator remote cable 5 lines LCD digital operator *1 + or Operator holder Filter option board RX *2 Blind cover LED digital operator Braking chopper Braking resistor Choke DC reactor Motor Output AC reactor Ground *1 *2 The 5 lines LCD digital operator is provided with the inverter from factory. When a communication option board is mounted, there are two options: mount a blind cover or a LED digital operator. RX frequency inverter 119 Specifications Type designation 3G3RX-A4004-E1F RX series F: Built-in filter A: B: IP20 IP00 E: Europe standard Max. applicable motor output 004: 0,4kW ~ Voltage: 2: Three-phase 200 VAC 4: Three-phase 400 VAC 13K: 132 kW 200 V class Three-phase: 3G3RX-@ Max. applicable motor 4P kW*1 Braking Power supply Output characteristics 200 V *1 Inverter capacity kVA 240 V Rated output current (A) A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550 at CT 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 at VT 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 at CT 1.0 1.7 2.5 3.6 5.7 8.3 11 15.9 22.1 26.3 32.9 41.9 50.2 63 76.2 at VT 1.3 2.1 3.2 4.1 6.7 10.4 15.2 20 26.3 29.4 39.1 49.5 59.2 72.7 93.5 at CT 1.2 2.0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4 at VT at CT at VT 1.5 3.0 3.7 2.6 5.0 6.3 3.9 7.5 9.4 5.0 10.5 12 8.1 16.5 19.6 12.4 18.2 24.1 31.5 35.3 24 32 46 64 76 30 44 58 73 85 Proportional to input voltage: 0 to 240 V 400 Hz 46.9 95 113 59.4 121 140 71 145 169 87.2 182 210 112.2 220 270 Max. output voltage Max. output frequency Rated input voltage and frequency Allowable voltage fluctuation Allowable frequency fluctuation Regenerative braking Minimum connectable resistance 3-phase 200 to 240 V 50/60 Hz –15% to +10% 5% Internal BRD circuit (external discharge resistor) 50 50 35 35 35 16 10 10 7.5 Protective structure IP20 Cooling method Forced air cooling 7.5 5 External regenerative braking unit Based on a standard 3-Phase standard motor. 400 V class Three-phase: 3G3RX-@ Max. applicable motor 4P kW*1 Braking Power supply Output characteristics 400 V Inverter capacity kVA 480 V Rated output current (A) A4004 A4007 A4015 A4022 A4040 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B4900 B411K B413K at CT 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 at VT 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 at CT 1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63 77.6 103.2 121.9 150.3 180.1 at VT 1.3 2.1 3.3 4.6 7.7 11 15.2 20.9 25.6 30.4 39.4 48.4 58.8 72.7 93.5 110.8 135 159.3 200.9 at CT 1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1 128.3 146.3 180.4 216.1 at VT at CT at VT 1.5 1.5 1.9 2.5 2.5 3.1 4.0 3.8 4.8 5.5 5.3 6.7 9.2 9.0 11.1 13.3 14 16 18.2 19 22 24.1 30.7 36.5 47.3 58.1 70.6 25 32 38 48 58 75 29 37 43 57 70 85 Proportional to input voltage: 0 to 480 V 400 Hz 87.2 91 105 112.2 112 135 133 149 160 162.1 176 195 191.2 217 230 241.1 260 290 Max. output voltage Max. output frequency Rated input voltage and frequency Allowable voltage fluctuation Allowable frequency fluctuation Regenerative braking Minimum connectable resistance 3-phase 380 to 480 V 50/60 Hz –15% to +10% 5% Internal BRD circuit (external discharge resistor) 100 Protective structure Cooling method *1 132 100 100 100 70 70 35 35 24 24 20 IP20 External regenerative braking unit IP00 Forced air cooling Based on a standard 3-Phase standard motor. 120 Frequency inverter Common specifications Model number 3G3RX Control mode Output frequency range 0.10 to 400.00 Hz Control functions Motor control Digital set value: ±0.01% of the max. frequency Analogue set value: ±0.2% of the max. frequency (25 ±10°C) Digital set value: 0.01 Hz Resolution of frequency set value Analog input: 12 bit Resolution of output frequency 0.01Hz 150%/0.3 Hz (under sensor-less vector control or sensor-less vector control at 0 Hz) Starting torque 200%/Torque at 0 Hz (under sensor-less vector control at 0Hz, when a motor size one rank lower than specified is connected) 150%/60 s, 200%/3 s for CT; 120%/60 s VT Overload capability Frequency precision Frequency set value 0 to 10 VDC (10 K), –10 to 10 VDC (10 K), 4 to 20 mA (100 ), EtherCAT communications V/f Characteristics Analogue inputs V/f optionally changeable at base frequencies of 30 to 400 Hz, V/f braking constant torque, reduction torque, sensor-less vector control, sensor-less vector control at 0 Hz 8 terminals, NO/NC switchable, sink/source logic switchable [Terminal function] 8 functions can be selected from among 61. Reverse (RV), Multi-step speed setting binary 1 (CF1), Multi-step speed setting binary 2 (CF2), Multi-step speed setting binary 3 (CF3), Multi-step speed setting binary 4 (CF4), Jogging (JG), DC injection braking (DB), 2nd control (SET), 2-step acceleration/deceleration (2CH), Free-run stop (FRS), External trip (EXT), USP function (USP), Commercial switching (CS), Soft lock (SFT), Analog input switching (AT), 3rd control (SET3), Reset (RS), 3-wire start (STA), 3-wire stop (STP), 3-wire forward/reverse (F/R), PID enabled/disabled (PID), PID integral reset (PIDC), Control gain switching (CAS), UP/DWN function accelerated (UP), UP/DWN function decelerated (DWN), UP/DWN function data clear (UDC), Forced operator (OPE), Multi-step speed setting bit 1 (SF1), Multi-step speed setting bit 2 (SF2), Multi-step speed setting bit 3 (SF3), Multi-step speed setting bit 4 (SF4), Multi-step speed setting bit 5 (SF5), Multi-step speed setting bit 6 (SF6), Multi-step speed setting bit 7 (SF7), Overload limit switching (OLR), Torque limit enabled (TL), Torque limit switching 1 (TRQ1), Torque limit switching 2 (TRQ2), P/PI switching (PPI), Brake confirmation (BOK), Orientation (ORT), LAD cancel (LAC), Position deviation clear (PCLR), Pulse train position command input permission (STAT), Frequency addition function (ADD), Forced terminal block (F-TM), Torque reference input permission (ATR), Integrated power clear (KHC), Servo ON (SON), Preliminary excitation (FOC), Analog command on hold (AHD), Position command selection 1 (CP1), Position command selection 2 (CP2), Position command selection 3 (CP3), Zero return limit signal (ORL), Zero return startup signal (ORG), Forward driving stop (FOT), Reverse driving stop (ROT), Speed/Position switching (SPD), Pulse counter (PCNT), Pulse counter clear (PCC), No allocation (no) 5 open collector output terminals: NO/NC switchable, sink/source logic switchable 1 relay (SPDT contact) output terminal: NO/NC switchable [Terminal function] 6 functions can be selected from among 45. Signal during RUN (RUN), Constant speed arrival signal (FA1), Over set frequency arrival signal (FA2), Overload warning (OL), Excessive PID deviation (OD), Alarm signal (AL), Set-frequency-only arrival signal (FA3), Overtorque (OTQ), Signal during momentary power interruption (IP), Signal during undervoltage (UV), Torque limit (TRQ), RUN time exceeded (RNT), Power ON time exceeded (ONT), Thermal warning (THM), Brake release (BRK), Brake error (BER), 0-Hz signal (ZS), Excessive speed deviation (DSE), Position ready (POK), Set frequency exceeded 2 (FA4), Set frequency only 2 (FA5), Overload warning 2 (OL2), Analog FV disconnection detection (FVDc), Analog FI disconnection detection (FIDc), Analog FE disconnection detection (FEDc), PID FB status output (FBV), Network error (NDc), Logic operation output 1 (LOG1), Logic operation output 2 (LOG2), Logic operation output 3 (LOG3), Logic operation output 4 (LOG4), Logic operation output 5 (LOG5), Logic operation output 6 (LOG6), Capacitor life warning (WAC), Cooling fan life warning (WAF), Starting contact signal (FR), Fin overheat warning (OHF), Light load detection signal (LOC), Operation ready (IRDY), Forward run (FWR), Reverse run (RVR), Fatal fault (MJA), Window comparator FV (WCFV), Window comparator FI (WCFI), Window comparator FE (WCFE), Alarm codes 0 to 3 (AC0 to AC3) V/f free setting (7), Upper/lower frequency limit, Frequency jump, Curve acceleration/deceleration, Manual torque boost level/ break, Energy-saving operation, Analog meter adjustment, Starting frequency, Carrier frequency adjustment, Electronic thermal function, (free setting available), External start/end (frequency/rate), Analog input selection, Trip retry, Restart during momentary power interruption, Various signal outputs, Reduced voltage startup, Overload limit, Initialization value setting, Automatic deceleration at power-off, AVR function, Automatic acceleration/deceleration, Auto tuning (Online/Offline), High torque multi-motor operation control (sensor-less vector control of two monitors with one inverter) Analogue inputs 0 to 10 V and –10 to 10 V (10 K), 4 to 20 mA (100 ) Analogue outputs Analog voltage output, Analog current output, Pulse train output Accel/Decel times 0.01 to 3600.0 s (line/curve selection) Functionality Inputs signals Output signals Standard functions Motor overload protection Status indicator LED’s Run, Program, Power, Alarm, Hz, Amps, Volts, % Digital operator: Available to monitor 23 items, output current, output frequency… Electronic Thermal overload relay and PTC thermistor input Instantaneous overcurrent 200% of rated current for 3 seconds Overload 150% for 1 minute Overvoltage 800 V for 400 V type and 400 V for 200 V type Momentary power loss Decelerates to stop with DC bus controlled, coast to stop Cooling fin overheat Temperature monitor and error detection Stall prevention level Stall prevention during acceleration, deceleration and constant speed Ground fault Detection at power on Power charge indication On when voltage between P and N is higher than 45 V Degree of protection IP20/IP00 Ambient humidity 90% RH or less (without condensation) Storage temperature –20°C to +65°C (short-term temperature during transportation) Ambient temperature –10C to 50C Installation Indoor (no corrosive gas, dust, etc.) Protection functions Display Ambient conditions Specifications Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, close loop vector with motor feedback, V/F) Speed, torque and indexer functionality Installation height Max. 1000 m Vibration 3G3RX-A004 to A220, 5.9 m/s2 (0.6G), 10 to 55 Hz 3G3RX-A300 to B13K, 2.94 m/s2 (0.3G), 10 to 55 Hz RX frequency inverter 121 Dimensions Figure 1 Figure 2 W W W1 W1 2-7 2-6 WARNING WARNING LOCAL REMOTE READ LOCAL REMOTE WRITE ESC READ WRITE ESC REV H H1 FWD 6 H REV H1 FWD D1 D2 D1 D D 7 W2 W2 Figure 4 Figure 3 2-7 W W W1 W1 2-10 (A2300 and A4300 models) 2-12 (A2370, A2450, A2550, A4370, A4450 and A4550 models) WARNING WARNING LOCAL REMOTE READ WRITE LOCAL REMOTE READ WRITE ESC ESC REV REV H1 H H1 FWD H FWD 7 D D1 D2 D 10 (A2300 and A4300 models) 12 (A2370, A2450, A2550, A4370, A4450 and A4550 models) W2 122 Frequency inverter Figure 5 2-12 WARNING H H1 LOCAL REMOTE READ WRITE ESC FWD REV 2-12 W1 D W Voltage class Inverter model 3G3RX@ Figure Dimensions in mm W W1 W2 H H1 D D1 D2 Weight (kg) 1 150 130 143 255 241 140 62 – 3.5 2 210 189 203 260 246 170 82 13.6 6 3 250 229 244 390 376 190 83 9.5 14 310 265 – 540 510 195 – – 20 390 300 – 550 520 250 – – 30 480 380 – 700 670 250 – – 43 1 150 130 143 255 241 140 62 – 3.5 2 210 189 203 260 246 170 82 13.6 6 3 250 229 244 390 376 190 83 9.5 14 310 265 – 540 510 195 – – 22 390 300 – 550 520 250 – – 30 390 300 – 700 670 270 – – 60 480 380 – 740 710 270 – – 80 A2004 A2007 A2015 A2022 A2037 A2055 A2075 Three-phase 200 V A2110 A2150 A2185 A2220 A2300 A2370 A2450 4 A2550 A4004 A4007 A4015 A4022 A4040 A4055 A4075 A4110 A4150 Three-phase 400 V A4185 A4220 A4300 A4370 A4450 4 A4550 B4750 B4900 B411K B413K RX frequency inverter 5 123 Rasmi filters Footprint dimensions H Book type dimensions W W Block type dimensions H H W drive mounts L X output flexes Voltage Inverter model L X L X Y Y Y Rasmi model Dimensions L W H X Y M 305 152 45 290 110 M5 Filter type Weight (kg) 3G3RX-A2004 3G3RX-A2007 3G3RX-A2015 AX-FIR2018-RE 3G3RX-A2022 2.0 Footprint 3G3RX-A2037 3G3RX-A2055 3G3RX-A2075 3×200 V AX-FIR2053-RE 320 212 56 296 189 M6 455 110 240 414 80 – 2.5 3G3RX-A2110 3G3RX-A2150 3G3RX-A2185 AX-FIR2110-RE 3G3RX-A2220 3G3RX-A2300 3G3RX-A2370 3G3RX-A2450 3G3RX-A2550 Book type AX-FIR2145-RE AX-FIR3250-RE 8.0 8.6 386 260 135 240 235 – Block type AX-FIR3320-RE 13 13.2 3G3RX-A4004 3G3RX-A4007 3G3RX-A4015 AX-FIR3010-RE 305 152 45 290 110 M5 AX-FIR3030-RE 312 212 50 296 189 M6 AX-FIR3053-RE 451 252 60 435 229 M6 3G3RX-A4300 AX-FIR3064-RE 598 310 70 578 265 M8 3G3RX-A4370 AX-FIR3100-RE 1.4 3G3RX-A4022 3G3RX-A4040 3G3RX-A4055 3G3RX-A4075 Footprint 2.2 3G3RX-A4110 3G3RX-A4150 3×400 V 3G3RX-A4185 4.5 3G3RX-A4220 3G3RX-A4450 3G3RX-A4550 3G3RX-B4750 3G3RX-B4900 3G3RX-B411K 3G3RX-B413K 124 AX-FIR3130-RE 7.0 8.0 486 110 240 414 80 – Book type 386 260 135 240 235 – Block type AX-FIR3250-RE AX-FIR3320-RE 8.6 13.0 13.2 Frequency inverter Input AC Reactor Voltage Dimensions Reference A AX-RAI02800100-DE B1 120 AX-RAI00880200-DE – AX-RAI00180670-DE D E F 120 80 62 5.5 190 105 AX-RAI00042300-DE C2 140 205 AX-RAI00071550-DE 240 130 AX-RAI07700050-DE – 205 210 120 – 200 AX-RAI00740335-DE AX-RAI00360500-DE 120 80 AX-RAI01300170-DE 85 – 180 AX-RAI00290780-DE AX-RAI00111850-DE 110 240 AX.RAI00072700-DE 165 – 140 205 105 AX-RAI00191150-DE 80 190 – 2.35 5.5 55 6.5 6 11.7 75 16.0 52 1.78 5.5 62 200 – 2.35 2.5 5.5 55 6.5 85 275 210 Weight (kg) 85 70 AX-RAI03500100-DE 400 V – 85 180 AX-RAI00091000-DE C1 80 AX-RAI00350335-DE 200 V B2 11.7 6 75 16.0 110 27.0 DC reactor Figure 1 Figure 2 B C F D E A Reference AX-RC 10700032-DE 06750061-DE 03510093-DE 02510138-DE 01600223-DE 01110309-DE 00840437-DE 00590614-DE 00440859-DE 00301275-DE 00231662-DE 00192015-DE 00162500-DE 00133057-DE Fig A 84 1 108 120 150 195 2 240 RX frequency inverter B 113 200 V Dimensions C D E 96 105 116 124 136 152 146 160 177 182.6 161 162.5 196 188 198 200 228 135 F G 66 5 120 82 6.5 135 94 160 115 7.5 228 2 9.5 9.5 7 88 123 109 119 149 kg 1.22 101 185 H – 2 10 – 12 – 1.60 1.95 3.20 5.20 6.00 11.4 14.3 17.0 25.5 34.0 38.0 42.0 Reference AX-RC 43000020-DE 27000030-DE 14000047-DE 10100069-DE 06400116-DE 04410167-DE 03350219-DE 02330307-DE 01750430-DE 01200644-DE 00920797-DE 00741042-DE 00611236-DE 00501529-DE 00372094-DE 00312446-DE 00252981-DE 00213613-DE Fig A 84 1 108 120 150 195 2 240 300 B 113 400 V Dimensions C D E 96 105 116 133 136 152 146 160 177 182.6 161 162.5 196 188 198 200 228 135 216 236 250 F G H 101 66 5 120 82 6.5 135 94 7 160 115 7 7.5 2 9.5 9.5 – 185 228 88 123 109 119 149 288 kg 1.22 2 10 – 12 – 1.60 1.95 3.70 5.20 6.00 11.4 14.3 17.0 25.5 34.0 38.0 42.0 48.0 133 67.0 153 79.0 125 Output AC reactor Dimensions A B1 B2 C1 C2 D E F Weight kg AX-RAO11500026-DE 120 – 70 – 120 80 52 5.5 1.78 AX-RAO07600042-DE 120 – 70 – 120 80 52 5.5 1.78 AX-RAO04100075-DE 120 – 80 – 120 80 62 5.5 2.35 AX-RAO03000105-DE 120 – 80 – 120 80 62 5.5 2.35 AX-RAO01830160-DE 180 – 85 – 190 140 55 6 5.5 AX-RAO01150220-DE 180 – 85 – 190 140 55 6 5.5 AX-RAO00950320-DE 180 – 85 – 205 140 55 6 6.5 AX-RAO00630430-DE 180 – 95 – 205 140 65 6 9.1 AX-RAO00490640-DE 180 – 95 – 205 140 65 6 9.1 AX-RAO00390800-DE 240 – 110 – 275 200 75 6 16.0 AX-RAO00330950-DE 240 – 110 – 275 200 75 6 16.0 AX-RAO00251210-DE 240 – 110 – 275 200 75 6 16.0 AX-RAO00191450-DE 240 – 120 – 275 200 85 6 18.6 AX-RAO00161820-DE 240 – 150 – 275 200 110 6 27.0 AX-RAO00132200-DE 240 165 – 210 – 200 110 6 27.0 AX-RAO16300038-DE 120 – 70 – 120 80 52 5.5 1.78 AX-RAO11800053-DE 120 – 80 – 120 80 52 5.5 2.35 AX-RAO07300080-DE 120 – 80 – 120 80 62 5.5 2.35 AX-RAO04600110-DE 180 – 85 – 190 140 55 6 5.5 AX-RAO03600160-DE 180 – 85 – 205 140 55 6 6.5 AX-RAO02500220-DE 180 – 95 – 205 140 55 6 9.1 AX-RAO02000320-DE 180 – 105 – 205 140 85 6 11.7 AX-RAO01650400-DE 240 – 110 – 275 200 75 6 16.0 AX-RAO01300480-DE 240 – 120 – 275 200 85 6 18.6 AX-RAO01030580-DE 240 – 120 – 275 200 85 6 18.6 AX-RAO00800750-DE 240 – 120 – 275 200 110 6 27.0 AX-RAO00680900-DE 240 – 150 – 275 200 110 6 27.0 AX-RAO00531100-DE 240 – 150 – 275 200 110 6 27.0 AX-RAO00401490-DE 300 – 165 – 320 200 125 6 44.0 AX-RAO00331760-DE 300 – 165 – 320 200 125 6 44.0 AX-RAO00262170-DE 360 230 – 300 – 300 145 8 70.0 AX-RAO00212600-DE 360 230 – 300 – 300 145 8 70.0 Reference Chokes X Dimensions Reference D diameter Motor KW L W H X Y m Weight kg AX-FER2102-RE 21 < 2.2 85 22 46 70 – 5 0.1 AX-FER2515-RE 25 < 15 105 25 62 90 – 5 0.2 AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7 AX-FER6055-RE 60 < 55 200 65 170 180 45 6 1.7 L H 126 Øm W Y Ød Frequency inverter Braking unit dimensions B S Dimensions H H1 T S 82.5 40.5 150 138 220 6 BC... C HOPP ER OVERCURRENT ACTIVE POWER AX-BCR4035090-TE H AX-BCR2070130-TE H1 AX-BCR2035090-TE 130 64.5 205 193 208 6 131 64.5 298 280 300 9 DANGER HIGH VOLTAGE ! AX-BCR4090240-TE BUSS AX-BCR4070130-TE R AX-BCR4017068-TE B1 R AX-BCR4015045-TE B BUSS+ Reference B1 T Resistor dimensions Fig 1 AX-REM00K1xxx Fig 5 Fig 3 Type Fig 2 Fig 4 Weight Dimensions Fig. L H M I T G N kg 105 27 36 94 – – – 0.2 200 27 36 189 – – – 0.425 260 27 36 249 – – – 0.58 320 27 36 309 – – – 0.73 2 200 61 100 74 211 40 230 1.41 3 365 73 105 350 70 – – 4 310 100 240 295 210 – – 7 365 100 240 350 210 – – 8 206 350 140 190 50 – – 8.1 306 350 140 290 50 – – 14.5 AX-REM00K2070-IE AX-REM00K2120-IE AX-REM00K2200-IE AX-REM00K4075-IE AX-REM00K4035-IE 1 AX-REM00K4030-IE AX-REM00K5120-IE AX-REM00K6100-IE AX-REM00K6035-IE AX-REM00K9070-IE AX-REM00K9020-IE AX-REM00K9017-IE AX-REM01K9070-IE AX-REM01K9017-IE AX-REM02K1070-IE AX-REM02K1017-IE AX-REM03K5035-IE 4 AX-REM03K5010-IE AX-REM19K0006-IE AX-REM19K0008-IE AX-REM19K0020-IE 5 AX-REM19K0030-IE AX-REM38K0012-IE RX frequency inverter 127 Standard connections Braking resistor (optional) DC reactor (optional) PD/+1 R/L1 3-phase 200 VAC 3-phase 400 VAC Short-circuit wire N/– RB U/T1 S/L2 V/T2 T/L3 W/T3 J51 To wire the control circuit power supply and main circuit power supply separately, be sure to remove the J51 connector Control circuit wire first. power supply P/+ M R T AL1 Ro AL2 To AL0 Relay output *1 Common CM1 11 PLC 12 24 VDC FW Multi-function input 1 13 1 14 Multi-function input 2 2 Multi-function input 3 3 15 Multi-function input 4 4 CM2 Multi-function input 5 5 Multi-function input 6 6 Multi-function input 7 7 Multi-function input 8 8 Multi-function output 2 Multi-function output 3 Multi-function output 4 Multi-function output 5 Multi-function output common SP SN RP Sequence input common Multi-function output 1 P24 SN RS485 communication For termination resistors CM1 Thermistor TH Frequency setting unit 500 to 2 k *1 Frequency reference power supply Frequency reference input (voltage) Frequency reference auxiliary input (voltage) Frequency reference input (current) Frequency reference common H AM Analog monitor output (voltage output) AMI Analog monitor output (current output) FM Digital monitor output (PWM output) O 10 k O2 Option 1 10 k 10 VDC OI 100  *1 L Option 2 L is the common reference for analog input and also for analog output. Terminal block specifications Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 PD/+1, P/+ P/+, RB P/+, N/– 128 Name Function (signal level) Main circuit power supply input Used to connect line power to the drive. Inverter output Used to connect the motor External DC reactor terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/+2 when a DC reactor is connected. Braking resistor connection terminals Regenerative braking unit connection terminal Grounding Connect option braking resistor (if a braking torque is required) Connect optional regenerative braking units. For grounding (grounding should conform to the local grounding code.) Frequency inverter Control circuit Function H Frequency reference power supply 10 VDC 20 mA max O Voltage frequency reference input 0 to 12 VDC (10 k) O2 Voltage auxiliary frequency reference 0 to ±12 VDC (10 k) OI Current frequency reference input 4 to 20 mA (100 ) L Frequency reference common Common terminal for analog monitor (AM, AMI) terminals Multi-function analog voltage output Factory setting: Output frequency No. Frequency reference input Signal name Type Function selection Power Supply Monitor Output AM AMI Multi-function analog current output Factory setting: Output frequency FM PWM monitor output Factory setting: Output frequency P24 Internal 24 VDC Power supply for contact input signal CM1 Input common Common terminal for P24, TH and FM digital monitor FW Forward rotation command terminal Motor runs in forwards direction when FW is ON 1 Factory setting: Reverse (RV) 2 Factory setting: External trip (EXT) 3 Factory setting: Reset (RS) 4 Factory setting: Multi-step speed reference 1 (CF1) Multi-function input 5 Factory setting: Multi-step speed reference 2 (CF2) 6 Factory setting: Jogging (JG) 7 Factory setting: Second control (SET) 8 Factory setting: No allocation (NO) PLC Multi-function input common Status/Factor Relay output 100 mA max 27 VDC max Input imped 4.7 k Max current 5.6 mA On: 18 VDC or more Sink logic: Short-circuiting P24 and PLC Source logic: Short-circuiting PLC and CM1 With external supply remove short-circuit bar Factory setting: 0 Hz signal (ZS) 12 Multi-function output Factory setting: Overload warning (OL) 14 Factory setting: Overtorque (OTQ) 15 Factory setting: Constant speed arrival (FA1) CM2 Multi-function output common AL1 Relay output (Normally close) AL2 Relay output (Normally open) R load Factory setting: Alarm output (AL) MA-MC open Relay output common 27 VDC max 50 mA max Common terminal for multi-function output terminals 11 to 15 Under normal operation AL0 2 mA max 4 to 20 mA (max imp 250 ) 0 to 10 VDC Max 3.6 kHz Factory setting: During Run (RUN) 11 13 Signal level MB-MC close AL1-AL0 250 VAC 2 A AL2-AL0 250 VAC 1 A I load 250 VAC 0.2 A SC terminal functions as the common terminal Sensor TH External thermistor input terminal 100 mW minimum 0 to 8 VDC Impedance at temperature error: 3 k Comms SP RS485 Modbus terminals – Differential input RS485 terminating resistor terminals – - SN RP SN RX frequency inverter 129 Inverter heat loss Three-phase 200 V class Inverter capacity kVA Model 3G3RX- A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550 1.0 1.7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2 200 V 240 V Heat loss W Rated current (A) Losses at 70% load Losses at 100% load Efficiency at rated output 1.2 2.0 3.1 4.3 6.8 3.0 64 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4 5.0 7.5 10.5 16.5 24 32 46 64 76 95 121 145 182 220 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975 70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800 85.1 89.5 92.3 93.2 94.0 94.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1 Forced-air-cooling Cooling Method Three-phase 400 V class Inverter capacity kVA Model 3G3RX400 V 480 V Heat loss W Rated current (A) A4004 A4007 A4015 A4022 A4040 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B4900 B411K B413K 1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1 1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1 123.8 146.3 180.4 216.1 1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 48 58 75 91 112 149 176 217 260 3375 3900 4670 Losses at 70% load 64 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975 2675 Losses at 100% load 70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800 3800 4800 5550 6650 85.1 89.5 92.3 93.2 94.0 64.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1 95.2 95.2 95.2 95.2 Efficiency at rated output Cooling Method Forced-air-cooling Input AC Reactor AC reactor Power supply Max. applicable motor output kW 0.4 to 1.5 2.2 to 3.7 5.5 to 7.5 11.0 to 15.0 18.5 to 22.0 30.0 to 37.0 45.0 to 55.0 130 3 phase 200 V class Current value A AX-RAI02800100-DE 10.0 AX-RAI00880200-DE 20.0 AX-RAI00350335-DE 33.5 AX-RAI00180670-DE 67.0 AX-RAI00091000-DE 100.0 AX-RAI00071550-DE 155.0 AX-RAI00042300-DE 230.0 Reference MCCB RX U X R/L1 V Y S/L2 W Z T/L3 Inductance mH 2.8 0.88 0.35 0.18 0.09 0.07 0.04 Max. applicable motor output kW 0.4 to 1.5 2.2 to 3.7 5.5 to 7.5 11.0 to 15.0 18.5 to 22.0 30.0 to 37.0 45.0 to 55.0 75.0 to 90.0 110.0 to 132.0 400 V class Current value A 5.0 AX-RAI07700050-DE AX-RAI03500100-DE 10.0 17.0 AX-RAI01300170-DE 33.5 AX-RAI00740335-DE 50.0 AX-RAI00360500-DE 78.0 AX-RAI00290780-DE 115.0 AX-RAI00191150-DE 185.0 AX-RAI00111850-DE 270.0 AX.RAI00072700-DE Reference Inductance mH 7.7 3.5 1.3 0.74 0.36 0.29 0.19 0.11 0.07 Frequency inverter DC Reactor RX Power supply MCCB R/L1 S/L2 T/L3 PD/+1 P/+ DC reactor Max. applicable motor output kW 0.4 0.7 1.5 2.2 3.7 5.5 7.5 11.0 15.0 18.5 to 22 30 37 45 55 200 V class Current value Reference A AX-RC10700032-DE 3.2 AX-RC06750061-DE 6.1 AX-RC03510093-DE 9.3 AX-RC02510138-DE 13.8 AX-RC01600223-DE 22.3 AX-RC01110309-DE 30.9 AX-RC00840437-DE 43.7 AX-RC00590614-DE 61.4 AX-RC00440859-DE 85.9 AX-RC00301275-DE 127.5 AX-RC00231662-DE 166.2 AX-RC00192015-DE 201.5 AX-RC00162500-DE 250.0 AX-RC00133057-DE 305.7 400 V class Current value A 2.0 AX-RC43000020-DE AX-RC27000030-DE 3.0 4.7 AX-RC14000047-DE AX-RC10100069-DE 6.9 AX-RC06400116-DE 11.6 AX-RC04410167-DE 16.7 AX-RC03350219-DE 21.9 AX-RC02330307-DE 30.7 AX-RC01750430-DE 43.0 AX-RC01200644-DE 64.4 AX-RC00920797-DE 79.7 AX-RC00741042-DE 104.2 AX-RC00611236-DE 123.6 AX-RC00501529-DE 152.9 AX-RC00372094-DE 209.4 AX-RC00312446-DE 244.6 AX-RC00252981-DE 298.1 AX-RC00213613-DE 361.3 Inductance mH 43.00 27.00 14.00 10.10 6.40 4.41 3.35 2.33 1.75 1.20 0.92 0.74 0.61 0.50 0.37 0.31 0.25 0.21 400 V class Current value A Inductance mH Inductance mH 10.70 6.75 3.51 2.51 1.60 1.11 0.84 0.59 0.44 0.30 0.23 0.19 0.16 0.13 Max. applicable motor output kW 0.4 0.7 1.5 2.2 4.0 5.5 7.5 11.0 15.0 18.5 to 22 30 37 45 55 75 90 110 132 Inductance mH 11.50 7.60 4.10 3.00 1.83 1.15 0.95 0.63 0.49 0.39 0.33 0.25 0.19 0.16 0.13 Max. applicable motor output kW*1 Reference 0.4 to 1.5 AX-RAO16300038-DE 3.8 16.30 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 AX-RAO11800053-DE AX-RAO07300080-DE AX-RAO04600110-DE AX-RAO03600160-DE AX-RAO02500220-DE AX-RAO02000320-DE AX-RAO01650400-DE AX-RAO01300480-DE AX-RAO01030580-DE AX-RAO00800750-DE AX-RAO00680900-DE AX-RAO00531100-DE AX-RAO00401490-DE AX-RAO00331760-DE AX-RAO00262170-DE AX-RAO00212600-DE 5.3 8.0 11.0 16.0 22.0 32.0 40.0 48.0 58.0 75.0 90.0 110.0 149.0 176.0 217.0 260.0 11.80 7.30 4.60 3.60 2.50 2.00 1.65 1.30 1.03 0.80 0.68 0.53 0.40 0.33 0.26 0.21 Reference Output AC Reactor Max. applicable motor output kW* 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 *1 200 V class Current value A AX-RAO11500026-DE 2.6 AX-RAO07600042-DE 4.2 AX-RAO04100075-DE 7.5 AX-RAO03000105-DE 10.5 AX-RAO01830160-DE 16.0 AX-RAO01150220-DE 22.0 AX-RAO00950320-DE 32.0 AX-RAO00630430-DE 43.0 AX-RAO00490640-DE 64.0 AX-RAO00390800-DE 80.0 AX-RAO00330950-DE 95.0 AX-RAO00251210-DE 121.0 AX-RAO00191450-DE 145.0 AX-RAO00161820-DE 182.0 AX-RAO00132200-DE 220.0 Reference These motor sizes are for heavy duty applications. Braking Unit Voltage 200 V 400 V AX-BCR2035090-TE AX-BCR2070130-TE AX-BCR4015045-TE AX-BCR4017068-TE AX-BCR4035090-TE AX-BCR4070130-TE AX-BCR4090240-TE RX frequency inverter Specifications Peak (5 s max) Permanent Reference Current (A) Brake power (kVA) Current (A) Brake power (kVA) 35 70 15 17 35 70 90 13 25 11 13 26 52 67 90 130 45 68 90 130 240 32 47 33 51 67 97 180 Minimum connectable resistor (Ohms) 4 2.8 16 11 8.5 5.5 3.2 131 Ordering information Power supply B RJ45 - USB cable E MCCB Software A + + Input AC reactor Digital operator options A B Digital operator remote cable 5 lines LCD B digital operator *1 + or Operator holder B Filter LED digital operator B Blind cover C option board *2 B D RX Braking chopper D Braking resistor A A Choke DC reactor Motor A Output AC reactor Ground *1 *2 The 5 lines LCD digital operator is provided with the inverter from factory. When a communication option board is mounted, there are two options: mount a blind cover or a LED digital operator. 3G3RX Voltage class Three-phase 200 V Specifications Constant torque Variable torque Rated Max Rated Max motor current motor current kW A kW A Standard Voltage class Specifications Constant torque Variable torque Rated Max Rated Max motor current motor current kW A kW A Model Standard 0.4 3.0 0.75 3.7 3G3RX-A2004-E1F 0.4 1.5 0.75 1.9 3G3RX-A4004-E1F 0.75 5.0 1.5 6.3 3G3RX-A2007-E1F 0.75 2.5 1.5 3.1 3G3RX-A4007-E1F 1.5 7.5 2.2 9.4 3G3RX-A2015-E1F 1.5 3.8 2.2 4.8 3G3RX-A4015-E1F 2.2 10.5 4.0 12 3G3RX-A2022-E1F 2.2 5.3 4.0 6.7 3G3RX-A4022-E1F 4.0 16.5 5.5 19.6 3G3RX-A2037-E1F 4.0 9.0 5.5 11.1 3G3RX-A4040-E1F 5.5 24 7.5 30 3G3RX-A2055-E1F 5.5 14 7.5 16 3G3RX-A4055-E1F 7.5 32 11 44 3G3RX-A2075-E1F 7.5 19 11 22 3G3RX-A4075-E1F 11 46 15 58 3G3RX-A2110-E1F 11 25 15 29 3G3RX-A4110-E1F 15 64 18.5 73 3G3RX-A2150-E1F 15 32 18.5 37 3G3RX-A4150-E1F 18.5 76 22 85 3G3RX-A2185-E1F 18.5 38 22 43 3G3RX-A4185-E1F 22 95 30 113 3G3RX-A2220-E1F 22 48 30 57 3G3RX-A4220-E1F 30 121 37 140 3G3RX-A2300-E1F 30 58 37 70 3G3RX-A4300-E1F 37 145 45 169 3G3RX-A2370-E1F 37 75 45 85 3G3RX-A4370-E1F 45 182 55 210 3G3RX-A2450-E1F 45 91 55 105 3G3RX-A4450-E1F 55 220 75 270 3G3RX-A2550-E1F 55 112 75 135 3G3RX-A4550-E1F 75 149 90 160 3G3RX-B4750-E1F 90 176 110 195 3G3RX-B4900-E1F 110 217 132 230 3G3RX-B411K-E1F 132 260 160 290 3G3RX-B413K-E1F - 132 Model Three-phase 400 V Frequency inverter A Line filters Rasmi Line filter 200V Model 3G3RX-@ Reference 400V Rated current (A) Leakage Nom/max kg Model 3G3RX-@ Reference Rated current (A) Leakage Nom/max kg 2.0 A4004/A4007/A4015/ A4022/A4040 AX-FIR3010-RE 10 0.3/40 mA 1.9 2.2 A2004/A2007/A2015/ A2022/A2037 AX-FIR2018-RE A2055/A2075/A2110 AX-FIR2053-RE 53 0.7/40 mA 2.5 A4055/A4075/A4110 AX-FIR3030-RE 30 0.3/40 mA A2150/A2185/A2220 AX-FIR2110-RE 110 1.2/70 mA 8.0 A4150/A4185/A4220 AX-FIR3053-RE 53 0.8/70 mA 4.5 A2300 AX-FIR2145-RE 145 1.2/70 mA 8.6 A4300 AX-FIR3064-RE 64 3/160 mA 7.0 A2370/A2450 AX-FIR3250-RE 250 6/300 mA 13.0 A4370 AX-FIR3100-RE 100 2/130 mA 8.0 A2550 AX-FIR3320-RE 320 6/300 mA 13.2 A4450/A4550 AX-FIR3130-RE 130 2/130 mA 8.6 A4750/A4900 AX-FIR3250-RE 250 10/500 mA 13.0 A411K/A413K AX-FIR3320-RE 320 10/500 mA 13.2 18 0.7/40 mA - A Input AC Reactors Voltage 3-phase 200 VAC AC Reactor Reference Inverter Model 3G3RX-@ 3-phase 400 VAC AC Reactor Reference Inverter Model 3G3RX-@ A2004/A2007/A2015 AX-RAI02800100-DE A4004/A4007/A4015 AX-RAI07700050-DE A2022/A2037 AX-RAI00880200-DE A4022/A4040 AX-RAI03500100-DE A2055/A2075 AX-RAI00350335-DE A4055/A4075 AX-RAI01300170-DE A2110/A2150 AX-RAI00180670-DE A4110/A4150 AX-RAI00740335-DE A2185/A2220 AX-RAI00091000-DE A4185/A4220 AX-RAI00360500-DE A2300/A2370 AX-RAI00071550-DE A4300/A4370 AX-RAI00290780-DE A2450/A2550 AX-RAI00042300-DE A4450/A4550 AX-RAI00191150-DE A4750/A4900 AX-RAI00111850-DE A411K/A413K AX.RAI00072700-DE A DC Reactors Voltage 3-phase 200 VAC Inverter Model 3G3RX-@ AC Reactor Reference 3-phase 400 VAC Inverter Model 3G3RX-@ AC Reactor Reference A2004 AX-RC10700032-DE A4004 AX-RC43000020-DE A2007 AX-RC06750061-DE A4007 AX-RC27000030-DE A2015 AX-RC03510093-DE A4015 AX-RC14000047-DE A2022 AX-RC02510138-DE A4022 AX-RC10100069-DE A2037 AX-RC01600223-DE A4040 AX-RC06400116-DE A2055 AX-RC01110309-DE A4055 AX-RC04410167-DE A2075 AX-RC00840437-DE A4075 AX-RC03350219-DE A2110 AX-RC00590614-DE A4110 AX-RC02330307-DE A2150 AX-RC00440859-DE A4150 AX-RC01750430-DE A2185/A2220 AX-RC00301275-DE A4185/A4220 AX-RC01200644-DE A2300 AX-RC00231662-DE A4300 AX-RC00920797-DE A2370 AX-RC00192015-DE A4370 AX-RC00741042-DE A2450 AX-RC00162500-DE A4450 AX-RC00611236-DE A2550 AX-RC00133057-DE A4550 AX-RC00501529-DE A4750 AX-RC00372094-DE A4900 AX-RC00312446-DE A411K AX-RC00252981-DE A413K AX-RC00213613-DE A Chokes Model Diameter Description AX-FER2102-RE 21 For 2.2 kW motors or below AX-FER2515-RE 25 For 15 kW motors or below AX-FER5045-RE 50 For 45 kW motors or below AX-FER6055-RE 60 For 55 kW motors or above A Output AC Reactor Voltage 200V 400V Model 3G3RX-@ Reference A2004 AX-RAO11500026-DE A2007 AX-RAO07600042-DE A2015 AX-RAO04100075-DE A2022 A2037 A2055 RX frequency inverter Model 3G3RX-@ Reference A4004/A4007/A4015 AX-RAO16300038-DE AX-RAO03000105-DE A4022 AX-RAO11800053-DE AX-RAO01830160-DE A4040 AX-RAO07300080-DE AX-RAO01150220-DE A4055 AX-RAO04600110-DE 133 Voltage 200V 400V Model 3G3RX-@ Reference Model 3G3RX-@ Reference A2075 AX-RAO00950320-DE A4075 AX-RAO03600160-DE A2110 AX-RAO00630430-DE A4110 AX-RAO02500220-DE A2150 AX-RAO00490640-DE A4150 AX-RAO02000320-DE A2185 AX-RAO00390800-DE A4185 AX-RAO01650400-DE A2220 AX-RAO00330950-DE A4220 AX-RAO01300480-DE A2300 AX-RAO00251210-DE A4300 AX-RAO01030580-DE A2370 AX-RAO00191450-DE A4370 AX-RAO00800750-DE A2450 AX-RAO00161820-DE A4450 AX-RAO00680900-DE A2550 AX-RAO00132200-DE A4550 AX-RAO00531100-DE A4750 AX-RAO00401490-DE A4900 AX-RAO00331760-DE A411K AX-RAO00262170-DE A413K AX-RAO00212600-DE Note: This table corresponds with HD rating. When ND is used, please choose the reactor for the next size inverter. B Accessories Types Appearance Model 3G3AX-OP05 3G3AX-OP05-H-E Remote digital operator 3G3AX-OP01 4X-KITmini LED digital operator 3G3AX-OP03 Blind cover 3G3AX-OP05-B-E Description 5 Line LCD digital operator with copy function*1 Operator holder (for inside cabinet mounting) LED remote digital operator Mounting kit To be used in combination with communication option boards 3G3AX-CAJOP300-EE 3 m remote digital operator cable Cables *1 USB-CONVERTERCABLE 3G3AX-PCACN2 RJ45 to USB connection cable This digital operator is provided with the RX inverter from factory. C Option boards Communication Encoder option board Feedback Types 134 Model 3G3AX-PG 3G3AX-RX-ECT Description PG speed controller option card EtherCAT option card Functions Phase A,B and Z pulse (differential pulse) inputs (RS-422) Pulse train position command input (RS-422) Pulse monitor output (RS-422) PG frequency range: 100 kHz max Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current... through communications with the host controller. Frequency inverter D Braking unit, braking resistor unit Inverter Voltage 200 V (single-/ threephase) 400 V (threephase) Max. motor kW Inverter 3G3RX@ 0.55 2004 1.1 2007 1.5 2015 2.2 2022 4.0 2037 5.5 2055 7.5 2075 11.0 2110 15.0 2150 18.5 2185 22.0 2220 30.0 2300 37.0 2370 45.0 2450 55.0 2550 0.55 4004 1.1 4007 1.5 4015 2.2 4.0 5.5 4055 7.5 4075 11.0 4110 15.0 4150 18.5 4185 22.0 4220 30.0 4300 37.0 4370 45.0 4450 55.0 4550 75.0 4750 90.0 4900 110.0 411K 132.0 413K Braking resistor unit Braking Unit AX-BCR@ 3-phase Connectable min. resistance  50 35 16 Built-in 10 7.5 5 2035090-TE Inverter mounted type (3%ED, 10 sec max) Braking torque % External resistor 10%ED 10 sec max for built-in 5 sec max for Braking Unit Resist  Type AXREM00K1200-IE 200 Type AX- Resist  180 REM00K1200-IE 200 180 100 REM00K2070-IE 70 200 140 REM00K4075-IE 75 130 90 REM00K4035-IE 35 180 50 REM00K6035-IE 35 100 75 REM00K9020-IE 20 150 55 REM01K9017-IE 17 110 REM00K2070-IE 70 REM00K4075-IE 75 REM00K4035-IE 35 REM00K6035-IE 35 40 REM02K1017-IE 17 75 REM00K9017-IE 17 55 REM03K5010-IE 10 95 REM19K0008-IE 8 REM03K5010-IE 10 75 65 4 REM19K0006-IE – 2070130-TE 2.8 2 × REM19K0006-IE REM00K1400-IE 400 REM00K1200-IE 200 4022 REM00K2200-IE 4040 REM00K2120-IE 100 70 Built-in 35 24 20 4015045-TE 4017068-TE Braking torque % 200 6 95 80 80 6 60 3 105 3 85 200 REM00K1400-IE 400 190 REM00K2200-IE 200 190 200 130 REM00K5120-IE 120 200 120 120 REM00K6100-IE 100 140 140 REM00K9070-IE 70 150 100 REM01K9070-IE 70 110 200 200 REM00K4075-IE 75 REM00K6100-IE 100 50 REM02K1070-IE 70 75 REM00K9070-IE 70 55 REM03K5035-IE 35 110 REM03K5035-IE 35 REM19K0030-IE 30 REM19K0020-IE 20 16 11 90 75 REM38K0012-IE 15 2 × REM19K0020-IE 10 100 85 95 125 100 100 4035090-TE 8.5 3 × REM19K0030-IE 10 75 4070130-TE 5.5 2 × REM38K0012-IE 6 105 4090240-TE 3.2 3 × REM38K0012-IE 4 – 125 105 E Computer software Software Types Model Description Installation CX-Drive Computer software Configuration and monitoring software tool CX-One Computer software Configuration and monitoring software tool €Saver Computer software Software tool for Energy Saving calculation RX frequency inverter 135 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. SysCat_I116E-EN-05 136 In the interest of product improvement, specifications are subject to change without notice. Frequency inverter
3G3RX-A4450-E1F 价格&库存

很抱歉,暂时无法提供与“3G3RX-A4450-E1F”相匹配的价格&库存,您可以联系我们找货

免费人工找货