3G3RXA2004

3G3RXA2004

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Inverters Suitable For Various Advanced Applications

  • 数据手册
  • 价格&库存
3G3RXA2004 数据手册
Cat. No. I560-E2-04 RX Customised to your machine Model: 3G3RX 200 V Class Three-Phase Input 0.4 to 55 kW 400 V Class Three-Phase Input 0.4 to 132 kW USER’S MANUAL Introduction Introduction Thank you for choosing the general-purpose Inverter RX Series. This User's Manual (hereinafter called "this manual") describes the parameter setting methods required for installation/wiring and operation of the RX model, as well as troubleshooting and inspection methods.  This manual should be delivered to the actual end user of the product.  After reading this manual, keep it handy for future reference.  This manual describes the specifications and functions of the product as well as the relations between them. You should assume that anything not described in this manual is not possible with the product.  Intended readers This manual is intended for: Those with knowledge of the workings of electricity (qualified electric engineers or the equivalent), and also in charge of: • Introducing the control equipment • Designing the control system • Installing and/or connecting the control equipment • Field management 1 Read and Understand this Manual Read and Understand this Manual Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 2 Read and Understand this Manual Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3 Read and Understand this Manual Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 4 Safety Precautions Safety Precautions Indications and Meanings of Safety Information In this user's manual, the following precautions and signal words are used to provide information to ensure the safe use of the RX Inverter. The information provided here is vital to safety. Strictly observe the precautions provided. Meanings of Signal Words DANGER CAUTION Indicates an imminently hazardous situation which, if not avoided, is likely to result in serious injury or may result in death. Additionally there may be severe property damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Alert Symbols in this Document DANGER Turn off the power supply and implement wiring correctly. Not doing so may result in a serious injury due to an electric shock. Wiring work must be carried out only by qualified personnel. Not doing so may result in a serious injury due to an electric shock. Do not change wiring and slide switches (SW1), put on or take off Digital Operator and optional devices, replace cooling fans while the input power is being supplied. Doing so may result in a serious injury due to an electric shock. Be sure to ground the unit. Not doing so may result in a serious injury due to an electric shock or fire. (200-V class: type-D grounding, 400-V class: type-C grounding) Do not remove the terminal block cover during the power supply and 10 minutes after the power shutoff. Doing so may result in a serious injury due to an electric shock. Do not operate the Digital Operator or switches with wet hands. Doing so may result in a serious injury due to an electric shock. Inspection of the Inverter must be conducted after the power supply has been turned off. Not doing so may result in a serious injury due to an electric shock. The main power supply is not necessarily shut off even if the emergency shutoff function is activated. 5 Safety Precautions CAUTION Do not connect resistors to the terminals (PD/+1, P/+, N/-) directly. Doing so might result in a smallscale fire, heat generation or damage to the unit. Install a stop motion device to ensure safety. Not doing so might result in a minor injury. (A holding brake is not a stop motion device designed to ensure safety.) Be sure to use a specified type of braking resistor/regenerative braking unit. In case of a braking resistor, install a thermal relay that monitors the temperature of the resistor. Not doing so might result in a moderate burn due to the heat generated in the braking resistor/regenerative braking unit. Configure a sequence that enables the Inverter power to turn off when unusual overheating is detected in the braking resistor/regenerative braking unit. The Inverter has high voltage parts inside which, if short-circuited, might cause damage to itself or other property. Place covers on the openings or take other precautions to make sure that no metal objects such as cutting bits or lead wire scraps go inside when installing and wiring. Do not touch the Inverter fins, braking resistors and the motor, which become too hot during the power supply and for some time after the power shutoff. Doing so may result in a burn. Take safety precautions such as setting up a molded-case circuit breaker (MCCB) that matches the Inverter capacity on the power supply side. Not doing so might result in damage to property due to the short circuit of the load. Do not dismantle, repair or modify this product. Doing so may result in an injury. 6 Precautions for Safe Use Precautions for Safe Use Installation and Storage Do not store or use the product in the following places. •Locations subject to direct sunlight. •Locations subject to ambient temperature exceeding the specifications. •Locations subject to relative humidity exceeding the specifications. •Locations subject to condensation due to severe temperature fluctuations. •Locations subject to corrosive or flammable gases. •Locations subject to exposure to combustibles. •Locations subject to dust (especially iron dust) or salts. •Locations subject to exposure to water, oil, or chemicals. •Locations subject to shock or vibration. Transporting, Installation, and Wiring •Do not drop or apply strong impact on the product. Doing so may result in damaged parts or malfunction. •Do not hold by the front cover and terminal block cover, but hold by the fins during transportation. •Do not connect an AC power supply voltage to the control input/output terminals. Doing so may result in damage to the product. •Be sure to tighten the screws on the terminal block securely. Wiring work must be done after installing the unit body. •Do not connect any load other than a three-phase inductive motor to the U, V, and W output terminals. •Take sufficient shielding measures when using the product in the following locations. Not doing so may result in damage to the product. Locations subject to static electricity or other forms of noise. Locations subject to strong magnetic fields. Locations close to power lines. Operation and Adjustment •Be sure to confirm the permissible range of motors and machines before operation because the Inverter speed can be changed easily from low to high. •Provide a separate holding brake if necessary. Maintenance and Inspection •Be sure to confirm safety before conducting maintenance, inspection or parts replacement. 7 Precautions for Correct Use Precautions for Correct Use Installation •Mount the product vertically on a wall with the product's longer sides upright. The material of the wall has to be noninflammable such as a metal plate. Main Circuit Power Supply •Confirm that the rated input voltage of the Inverter is the same as AC power supply voltage. Error Retry Function •Do not come close to the machine when using the error retry function because the machine may abruptly start when stopped by an alarm. •Be sure to confirm the RUN signal is turned off before resetting the alarm because the machine may abruptly start. Non-Stop Function at Momentary Power Interruption •Do not come close to the machine when selecting restart in the non-stop function at momentary power interruption selection (b050) because the machine may abruptly start after the power is turned on. Operation Stop Command •Provide a separate emergency stop switch because the STOP key on the Digital Operator is valid only when function settings are performed. •When checking a signal during the power supply and the voltage is erroneously applied to the control input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal. Product Disposal •Comply with the local ordinance and regulations when disposing of the product. 8 Precautions for Correct Use Warning Labels Warning labels are located on the Inverter as shown in the following illustration. Be sure to follow the instructions. HITACHI WARNING LOCAL REMOTE READ WRITE ESC FWD REV Warning Description 9 Checking Before Unpacking Checking Before Unpacking Checking the Product On delivery, be sure to check that the delivered product is the Inverter RX model that you ordered. Should you find any problems with the product, immediately contact your nearest local sales representative or OMRON sales office. Checking the Nameplate Checking the Model 3G3RX-A2055-EF F: Built-in filter E: Europe standard Max. applicable motor capacity 004 007 015 022 037 040 055 075 110 150 0.4 kW 0.75 kW 1.5 kW 2.2 kW 3.7 kW 4.0 kW 5.5 kW 7.5 kW 11 kW 15 kW 185 220 300 370 450 550 750 900 11K 13K 18.5 kW 22 kW 30 kW 37 kW 45 kW 55 kW 75 kW 90 kW 110 kW 132 kW Voltage class 2 4 3-phase 200 V AC (200-V class) 3-phase 400 V AC (400-V class) Enclosure rating A Panel-mounting (IP20 min.) or closed wall-mounting models B IP00 Checking the Accessories Note that this manual is the only accessory included with the RX model. Mounting screws and other necessary parts must be provided by the user. 10 Revision History Revision History A manual revision code appears as a suffix to the catalog number located at the lower left of the front and back covers. Cat. No. I560-E2-04 Revision code Revision code Revision date 01 April 2009 04 February 2012 Description First version Major changes 11 About This Manual About This Manual This User's Manual is compiled chapter by chapter for user's convenience as follows. Understanding the following configuration ensures more effective use of the product. Overview 12 Chapter 1 Overview Describes features and names of parts. Chapter 2 Design Provides external dimensions, installation dimensions, peripheral device design/selection instructions, and other information necessary for design. Chapter 3 Operation Describes names of parts, the Inverter's operations, including how to use the keys on the Digital Operator, and the monitor function. Chapter 4 Functions Describes the functions of the Inverter. Chapter 5 Maintenance Operations Describes the causes and their countermeasures if the Inverter fails, including the solutions to possible troubles (troubleshooting). Chapter 6 Inspection and Maintenance Describes items for periodical inspection and/or maintenance for the Inverter. Chapter 7 Specifications Provides Inverter specifications, as well as the specifications and dimensions of peripheral devices. Appendix Describes the summarized parameter settings as a reference for users who have used this Inverter and understood the functions. Contents Introduction..............................................................................................1 Read and Understand this Manual ..........................................................2 Safety Precautions ..................................................................................5 Precautions for Safe Use.........................................................................7 Precautions for Correct Use ....................................................................8 Checking Before Unpacking ....................................................................10 Revision History.......................................................................................11 About This Manual...................................................................................12 Chapter 1 Overview 1-1 1-2 Functions .................................................................................................1-1 Appearance and Names of Parts.............................................................1-4 Chapter 2 Design 2-1 2-2 Installation................................................................................................2-1 Wiring.......................................................................................................2-5 Chapter 3 Operation 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-9 Operation Method ....................................................................................3-3 LCD Display.............................................................................................3-4 Test Run Procedure.................................................................................3-5 Operation .................................................................................................3-6 Read/Write function and operation ..........................................................3-13 Test Run Operation .................................................................................3-14 Part Names and Descriptions of the Digital Operator.............................. 3-17 Parameter Transition ...............................................................................3-19 Parameter List .........................................................................................3-21 Chapter 4 Functions 4-1 4-2 4-3 4-4 Monitor Mode...........................................................................................4-1 Function Mode .........................................................................................4-8 Functions When PG Option Board (3G3AX-PG01) Is Used....................4-123 Communication Function ........................................................................4-145 Chapter 5 Maintenance Operations 5-1 5-2 Protective Functions and Troubleshooting ..............................................5-1 Warning Function.....................................................................................5-10 Chapter 6 Inspection and Maintenance 6-1 Inspection and Maintenance....................................................................6-1 13 Contents Chapter 7 Specifications 7-1 7-2 7-3 Standard Specification List...................................................................... 7-1 Dimensional Drawing .............................................................................. 7-7 Options.................................................................................................... 7-15 Chapter App Appendix Appendix-1Parameter List ................................................................................. App-1 Appendix-2Product Life Curve ........................................................................... App-47 Appendix-3Life Alarm Output............................................................................. App-48 Appendix-4EC Declaration of Conformity .......................................................... App-49 Index..................................................................................................... Index-1 14 Chapter 1 Overview 1-1 Functions .......................................................... 1-1 1-2 Appearance and Names of Parts .................... 1-4 1-1 Functions 1Overview Overview 1 1-1 Functions RX Inverter Models Rated voltage Enclosure rating 3-phase 200 V AC Max. applicable motor capacity Model 0.4 kW 3G3RX-A2004 0.75 kW 3G3RX-A2007 1.5 kW 3G3RX-A2015 2.2 kW 3G3RX-A2022 3.7 kW 3G3RX-A2037 5.5 kW 3G3RX-A2055 7.5 kW 3G3RX-A2075 11 kW 3G3RX-A2110 15 kW 3G3RX-A2150 18.5 kW 3G3RX-A2185 22 kW 3G3RX-A2220 30 kW 3G3RX-A2300 37 kW 3G3RX-A2370 45 kW 3G3RX-A2450 55 kW 3G3RX-A2550 0.4 kW 3G3RX-A4004 0.75 kW 3G3RX-A4007 1.5 kW 3G3RX-A4015 2.2 kW 3G3RX-A4022 4.0 kW 3G3RX-A4040 5.5 kW 3G3RX-A4055 7.5 kW 3G3RX-A4075 11 kW 3G3RX-A4110 15 kW 3G3RX-A4150 18.5 kW 3G3RX-A4185 22 kW 3G3RX-A4220 30 kW 3G3RX-A4300 37 kW 3G3RX-A4370 45 kW 3G3RX-A4450 55 kW 3G3RX-A4550 75 kW 3G3RX-B4750 90 kW 3G3RX-B4900 110 kW 3G3RX-B411K 132 kW 3G3RX-B413K IP20 3-phase 400 V AC IP00 1-1 1-1 Functions International Standards Models (EC Directives and UL/cUL Standards) The RX Inverter meets the EC Directives and UL/cUL standard requirements for worldwide use. Classification EC Directives Applicable standard EN61800-3: 2004 Low-voltage Directive EN61800-5-1: 2007 Overview EMC Directive UL/cUL Standards 1 UL508C Human Environment-friendly, High-performance, General-purpose Inverters Suitable for Various Advanced Applications High Performance High Starting Torque With the vector control and auto-tuning functions, the RX Series has achieved high starting torque in excess of 200% at 0.3 Hz. Trip Suppression This Inverter features two trip suppression functions: "Overcurrent trip suppression function" to suppress overcurrent trip during acceleration, and "Overvoltage suppression function during deceleration" to suppress overvoltage trip during deceleration. Therefore, the RX Series provides tough operational capabilities regardless of the severe time setting of acceleration and deceleration. Various Applications Sensor-less Vector Control at 0 Hz The RX Series provides sensor-less vector control, which is useful for up/down applications. It can provide a high torque of 150%, even at a speed reference of 0 Hz (150% torque is available when the Inverter capacity is increased by one rank). This function contributes to simplification of control programs and extension of the service life of the brake. Emergency Shutoff Function By switching the dedicated switch (SW1) this function enables you to change the multi-function input (input 3) to the emergency shutoff input. You can directly turn off a motor control power module without operating the software. This function simplifies construction of safety applications. Built-in Braking Circuit (up to 22 kW) The Inverter models with 22 kW or lower capacity incorporate a braking transistor, enabling spacesaving configuration for applications that need rapid acceleration and stop. Restart Speed Search Function For a free-running motor (e.g. a fan motor), this function checks the direction of rotation and frequency, enabling smooth restart of the motor. High-torque Multi-operation The RX Series enables balanced torque control for the whole system, in proportion to multiple motor loads. Deceleration Stop During Power Failure During a power failure or momentary power interruption, the RX Series can decelerate and stop a motor by using the motor braking energy. 1-2 1-1 Functions Human Environment-friendly Features 1 More Simplified Parameter Settings and View Overview •Only parameters that have been changed from the default settings can be viewed. •With the user setting function, only 12 parameters for frequent use can be viewed. Compliance With Safety Standards The RX Series meets the requirements of the CE and UL/cUL and complies with various standards. The RoHS Directive The standard model meets the requirements of the RoHS Directive. Easily Meets the Requirements Specified by the Ministry of Land, Infrastructure and Transport of Japan The RX Series incorporates a zero-phase reactor (radio noise filter) as a standard specification. When an optional DC reactor is added, the RX Series meets the requirements specified by the Ministry of Land, Infrastructure and Transport of Japan. 1-3 1-2 Appearance and Names of Parts 1-2 Appearance and Names of Parts 1 Front cover HITACHI WARNING Digital Operator LOCAL REMOTE READ WRITE ESC FWD REV Terminal block cover Open the terminal block cover and you can connect cables to the main circuit terminal block, as well as the control circuit terminal block. Also, open the front cover and you can mount the optional board. Position for installing optional board 1 Position for installing optional board 2 Control circuit terminal block Main circuit terminal block Backing plate 1-4 Overview When the product is unpacked, it appears as below. (Example of 3G3RX-A2150/A4150 to A2220/ A4220) Chapter 2 Design 2-1 Installation ........................................................ 2-1 2-2 Wiring ................................................................ 2-5 2-1 Installation 2Design 2-1 Installation 2 Design DANGER Turn off the power supply and implement wiring correctly. Not doing so may result in a serious injury due to an electric shock. Wiring work must be carried out only by qualified personnel. Not doing so may result in a serious injury due to an electric shock. Do not change wiring and slide switches (SW1), put on or take off Digital Operator and optional devices, replace cooling fans while the input power is being supplied. Doing so may result in a serious injury due to an electric shock. Be sure to ground the unit. Not doing so may result in a serious injury due to an electric shock or fire. (200-V class: type-D grounding, 400-V class: type-C grounding) CAUTION Do not connect resistors to the terminals (PD/+1, P/+, N/-) directly. Doing so might result in a smallscale fire, heat generation or damage to the unit. Install a stop motion device to ensure safety. Not doing so might result in a minor injury. (A holding brake is not a stop motion device designed to ensure safety.) Be sure to use a specified type of braking resistor/regenerative braking unit. In case of a braking resistor, install a thermal relay that monitors the temperature of the resistor. Not doing so might result in a moderate burn due to the heat generated in the braking resistor/regenerative braking unit. Configure a sequence that enables the Inverter power to turn off when unusual overheating is detected in the braking resistor/regenerative braking unit. The Inverter has high voltage parts inside which, if short-circuited, might cause damage to itself or other property. Place covers on the openings or take other precautions to make sure that no metal objects such as cutting bits or lead wire scraps go inside when installing and wiring. 2-1 2-1 Installation Safety Information Installation and Storage Do not store or use the product in the following places. •Locations subject to direct sunlight. •Locations subject to ambient temperature exceeding the specifications. •Locations subject to relative humidity exceeding the specifications. •Locations subject to condensation due to severe temperature fluctuations. •Locations subject to corrosive or flammable gases. •Locations subject to exposure to combustibles. •Locations subject to dust (especially iron dust) or salts. •Locations subject to exposure to water, oil, or chemicals. •Locations subject to shock or vibration. 2 Design Transporting, Installation, and Wiring •Do not drop or apply strong impact on the product. Doing so may result in damaged parts or malfunction. •Do not hold by the front cover and terminal block cover, but hold by the fins during transportation. •Do not connect an AC power supply voltage to the control input/output terminals. Doing so may result in damage to the product. •Be sure to tighten the screws on the terminal block securely. Wiring work must be done after installing the unit body. •Do not connect any load other than a three-phase inductive motor to the U, V, and W output terminals. •Take sufficient shielding measures when using the product in the following locations. Not doing so may result in damage to the product. Locations subject to static electricity or other forms of noise. Locations subject to strong magnetic fields. Locations close to power lines. Precautions for Use Installation •Install the Inverter vertically on the wall. Install the Inverter on a nonflammable wall surface material, like metal. HIT ACH I WA ES HITACHI FW WARNING READ RE RN IN G AD WR RE IT E V WRITE HITACHI LOCAL REMOTE RELO MOCA TEL C D FWD READ REV WRITE REV WARNING ESC FWD LOCAL REMOTE ESC Position for installing a screw Main Circuit Power Supply •Confirm that the rated input voltage of the Inverter matches the AC power supply voltage. 2-2 2-1 Installation Installation Environment •Increased ambient temperatures will shorten the life of the Inverter. •Keep the Inverter away from heating elements (such as a braking resistor, DC reactor, etc.). If the Inverter is installed in an enclosure, keep the ambient temperature within the range of the specifications, taking dimensions and ventilation into consideration. 2 Save enough space to prevent the upper and lower wiring ducts from blocking cooling airflow. Inverter Design Airflow *1 Inverter 5 cm min. 5 cm min. *1 10 cm min. *2 10 cm min. Note that replacing the smoothing capacitor Wall requires 22 cm or more. *2 •When several RX models are installed in an enclosure and a ventilation fan is mounted in the enclosure, be careful about the layout of the Inverters and the air intake apertures. Depending on the internal layout of the panel, the Inverter's cooling effect may deteriorate, resulting in an increase in ambient temperature. Also, use thorough caution in making sure that the Inverter's ambient temperature is within the allowable operating temperature range. Ventilation fan Ventilation fan Inverter Inverter (Correct example) (Incorrect example) •Before installing the Inverter, place a cover over all the ventilation openings to shield them from foreign objects. After completing the installation process, be sure to remove the covers from the Inverter before operation. •Below is the heat radiation according to the Inverter capacity. Inverter capacity (kw) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 Load with 70% loss (W) 64 76 102 127 179 242 312 435 575 698 Load with 100% loss (W) 70 88 125 160 235 325 425 600 800 975 85.1 89.5 92.3 93.2 94.0 94.4 94.6 94.8 94.9 95.0 Inverter capacity (kw) 22 30 37 45 55 75 90 110 132 Load with 70% loss (W) 820 1100 1345 1625 1975 2675 3375 3900 4670 Load with 100% loss (W) 1150 1550 1900 2300 2800 3800 4800 5550 6650 Efficiency at rated output (%) 95.0 95.0 95.1 95.1 95.1 95.2 95.2 95.2 95.2 Efficiency at rated output (%) •To raise the carrier frequency, reduce the output current (or derate the rated current). 2-3 2-1 Installation Backing Plate  Inverter with 22 kW or Lower Capacity When running cables, cut the points between the backing plate and unnecessary portions with nippers or a wire cutter, and remove. 2 Connecting points Design Unnecessary portion  Inverter with 30 kW or Higher Capacity For Connection Without Cable Conduit Make a cut in the rubber bushing of the backing plate with nippers or a wire cutter, and insert a cable. Backing plate Rubber bushing For Connection With Cable Conduit Remove the rubber bushing from the conduit connecting portions, and connect the cable conduit. * Do not remove the rubber bushing unless you connect a cable conduit. Otherwise, the cable sheath may be damaged by the inner edge of the backing plate, resulting in short-circuit or ground fault. 2-4 2-2 Wiring 2-2 Wiring 2 Standard Connection Diagram Braking resistor (optional) Design DC reactor (optional) PD/+1 R/L1 3-phase 200 V AC 3-phase 400 V AC Short-circuit wire N/- RB U/T1 S/L2 V/T2 T/L3 W/T3 J51 To wire the control circuit power supply and main circuit power supply separately, be sure to remove the J51 connector Control circuit wire first. power supply P/+ M R T AL1 Ro AL2 To AL0 Relay output *1 Common CM1 11 PLC DC24V FW Multi-function input 1 12 13 1 14 Multi-function input 2 2 Multi-function input 3 3 15 Multi-function input 4 4 CM2 Multi-function input 5 5 Multi-function input 6 6 Multi-function input 7 7 Multi-function input 8 8 Multi-function output 2 Multi-function output 3 Multi-function output 4 Multi-function output 5 Multi-function output common SP SN RP Sequence input common Multi-function output 1 P24 SN RS485 communication For termination resistors CM1 Thermistor TH Frequency setting unit 500 to 2 kW Frequency reference power supply H Frequency reference input (voltage) O Frequency reference auxiliary input (voltage) O2 Frequency reference input (current) OI Frequency reference common *1 AM Analog monitor output (voltage output) AMI Analog monitor output (current output) FM Digital monitor output (PWM output) 10kW Option 1 10kW DC10V 100W *1 2-5 L L is the common reference for analog input and also for analog output. Option 1 2-2 Wiring  Main Circuit Terminals Terminal symbol Terminal name R/L1, S/L2, T/L3 Main power supply input terminal Connect the input power supply. U/T1,V/T2, W/T3 Inverter output terminal Connect to the 3-phase motor. PD/+1, P/+ External DC reactor terminal Remove the short-circuit bar between terminals "PD/+1" and "P/+", and connect the optional power factor improvement DC reactor. P/+, RB Braking resistor connection terminals Connect optional external braking resistors. (The RB terminal is provided for the Inverters with 22 kW or lower capacity.) P/+, N/- Regenerative braking unit connection terminal Connect optional regenerative braking units. Ground terminal Inverter case ground terminal. Connect this terminal to the ground. type-D (200-V class), type-C (400-V class) 2  Control Circuit Terminal Frequency reference input Analog Terminal symbol Terminal name Description Specifications H Frequency reference power supply output +10 V DC power supply for the O terminal. Allowable load current: 20 mA max. O Frequency reference input (Voltage) With a 0 to 10 V DC voltage input, the frequency reaches the maximum at 10 V. Set at A014 if the maximum frequency needs to be achieved at lower than 10 V. Input impedance 10 k Allowable input voltage range: -0.3 to +12 V DC O2 Auxiliary frequency reference input (Voltage) With a 0 to ±10 V DC voltage input, the O2 signal is added to the frequency reference signal of the O or OI terminal. By changing the setting, the frequency reference can be input even with the O2 terminal independently. Input impedance 10 k Allowable input voltage range: 0 to ±12 V DC OI Frequency reference input (Current) With a 4 to 20 mA DC current input, the maximum frequency is set at 20 mA. The OI signal is only active when the AT terminal is ON. Allocate the AT function to the multifunction input terminal. Input impedance 100  Allowable max. current: 24 mA L Frequency reference common Common terminal for the frequency setting signals (O, O2 and OI) and the analog output terminals (AM and AMI). Do not connect this terminal to the ground. Continued to the next page 2-6 Design G Description 2-2 Wiring Terminal symbol Terminal name Description AM Multi-function analog output (Voltage) This terminal outputs a signal selected from the "0 to 10 V DC Voltage Output" monitor items: Output frequency, Output current, Output torque (with/without sign), Output voltage, Input power, Electronic thermal load rate, LAD frequency, Motor temperature, and Fin temperature. Allowable max. current: 2 mA AMI Multi-function analog output (Current) This terminal outputs a signal selected from the "4 to 20 mA DC Current Output" monitor items: Output frequency, Output current, Output torque (without sign), Output voltage, Input power, Electronic thermal load rate, LAD frequency, Motor temperature, and Fin temperature. Allowable load impedance: 250  max. FM Multi-function digital output This terminal outputs a signal selected from the "0 to 10 V DC Voltage Output (PWM)" monitor items: Output frequency, Output current, Output torque (without sign), Output voltage, Input power, Electronic thermal load rate, LAD frequency, Motor temperature, Fin temperature, Digital output frequency, and Digital current monitor. "Digital output frequency", and "Digital current monitor" output a digital pulse at 0/10 V DC pulse voltage and 50% duty ratio. Allowable max. current: 1.2 mA Max. frequency: 3.6 kHz P24 Internal 24 V DC 24 V DC power supply for contact input signal. When the source logic is selected, this terminal functions as the contact input common terminal. Allowable max. output current: 100 mA CM1 Input common Common terminal for the interface power supply P24 terminal, thermistor input TH terminal and digital monitor FM terminal. When the sink logic is selected, this terminal functions as the contact input common terminal. Do not connect this terminal to the ground. Monitor output Monitor output Analog Power supply Digital (contact) Design 2 Specifications Continued to the next page 2-7 2-2 Wiring RUN command Status / Factor Status, alarm, etc. Open collector output Forward rotation command terminal Multi-function input Description Specifications When the FW signal is ON, the motor runs forward. When it is OFF, the motor decelerates and stops. [Contact input ON condition] Voltage between each input terminal and the PLC terminal :18 V DC or more 2 Input impedance between each input terminal and the PLC terminal: 4.7 k Select 8 functions from among the 61 functions and allocate them to terminals 1 to 8. Note: Only terminals 1 and 3 can be used for the emergency shutoff function. For details, refer to "Emergency Shutoff Function" (page 2-9). Function / Selection Contact input Digital (contact) 1 2 3 4 5 6 7 8 Allowable max. voltage: Voltage between each input terminal and the PLC terminal: 27 V DC Load current at 27 V DC power supply voltage: Approx. 5.6 mA PLC Relay output Digital (contact) FW Terminal name Design Terminal symbol 11 12 13 14 15 Multi-function input common The sink and source logic for contact input can be switched by connecting a short-circuit bar on the control terminal block. Short-circuiting P24 and PLC  Sink logic, Short-circuiting PLC and CM1  Source logic To activate contact input via an external power supply, remove the short-circuit bar and connect PLC terminal to the external interface circuit. Multi-function output Select 5 functions from among 45, and allocate them to terminals 11 through 15. If an alarm code is selected in C062, terminals 11 to 13, or terminals 11 to 14 always output an alarm factor code (e.g. Inverter trip). The signal between each terminal and CM2 always corresponds to the sink or source logic. CM2 Multi-function output common Common terminals for multi-function output terminals 11 to 15. AL2 AL1 Relay output AL0 Relay output common Select the desired functions from among 45 functions, and allocate them. SPDT contact output. By factory default, the relay output (AL2, AL1) contact selection (C036) is set at NC contact between AL2-AL0, and NO contact between AL1-AL0. Between each terminal and CM2 Voltage drop 4 V max. at power-on Max. allowable voltage: 27 V DC Max. allowable current: 50 mA Contact max. capacity AL2-AL0 250 V AC, 2 A (Resistance) 0.2 A (Induction) AL1-AL0 250 V AC, 1 A (Resistance) 0.2 A (Induction) Contact min. capacity 100 V AC, 10 mA 5 V DC, 100 mA Continued to the next page 2-8 2-2 Wiring Terminal symbol Design External thermistor input Terminal Sensor Analog input 2 Analog TH Terminal name Description Connect an external thermistor to this terminal, to trip the Inverter when a temperature error occurs. The CM1 terminal functions as the common terminal. [Recommended thermistor characteristics] Allowable rated power: 100 mW min. Impedance at temperature error: 3 k Temperature error detection level is adjustable between 0 and 9999 . Specifications Allowable input voltage range 0 to 8 V DC [Input circuit] 8 V DC 10 k TH Thermistor CM1 1 k Slide Switch (SW1) Settings The built-in slide switch is used to enable or disable the emergency shutoff function. (Factory Default: Disabled) * For the location of the slide switch, refer to (page 2-11). Emergency Shutoff Function (Factory Default: Disabled) •This function is intended to turn off the Inverter output (stop switching the main element) via only the multi-function input terminal of the hardware circuit without going through the CPU software. * This function stops switching of the main element.The circuit is not electrically turned off. While the power supply is ON, do not touch the Inverter terminals and power cable (e.g. motor cable). Doing so may result in electric shock, injury or ground fault. •When this function is enabled, the multi-function input terminals 1 and 3 are exclusively used for this function. No other function can be allocated to these terminals. If another function has been allocated, it will automatically be disabled, and terminals 1 and 3 are changed to the emergency shutoff terminals. Function of multi-function input terminal 1 Reset signal (RS) / NO contact (Fixed) This signal is used to reset the Inverter, and to reset the emergency shutoff trip [ E37.* ]. Function of multi-function input terminal 3 Emergency shutoff signal (EMR) / NC contact (Fixed) This signal is used to turn off the Inverter output without using the built-in CPU. With this signal input, the Inverter activates an emergency shutoff trip [ E37. * ]. * If multi-function input terminal 3 has not been connected or disconnected, or if the signal logic is not matched, the Inverter activates an emergency shutoff trip [E37. *]. After checking the cable connection and the signal logic, input the reset signal (RS). Emergency shutoff trip [ E37. * ] can be reset only by the reset signal (RS) via multi-function input terminal 1. (It cannot be reset with the Digital Operator.) •To enable this function, set the slide switch SW1 lever in the Inverter to [ON]. (With the factory default setting, slide switch SW1 is [OFF]. [This function is disabled.]) 2-9 2-2 Wiring * Before operating slide switch SW1, make sure that the input power supply is OFF. Slide switch SW1 setting and status of multi-function input terminals 1 and 3 Slide switch (SW1) setting SW1 ON Emergency shutoff: Enabled *5 Turning SW1 on, and then off Emergency shutoff: Disabled *3 *5 Multi-function input terminal 3 Multi-function input 1 selection [ C001 ] Multi-function input 1 operation selection [ C011 ]*1 Multi-function input 3 selection [ C003 ] Multi-function input 3 operation selection [ C013 ]*1 *2 [Can be selected randomly] *4 [Can be selected randomly] *4 [Can be selected randomly] *4 [Can be selected randomly] *4 Factory default 01 (RV) Factory default 00 (NO) Factory default 12 (EXT) Factory default 00 (NO) Automatic allocation to multi-function input terminals 1 and 3, and the input terminal with 18 (RS) setting *3 Fixed function (Cannot be changed) 18 (RS) [Can be selected randomly] *4 Holds setting while SW1 is ON. 18 (RS) Fixed function (Cannot be changed) 00 (NO) [Can be selected randomly] *4 Holds setting while SW1 is ON. 00 (NO) Fixed function (Cannot be changed) 64 (EMR) [Can be selected randomly] *4 Emergency shutoff function: Reset no (no allocation) Fixed function (Cannot be changed) 01 (NC) [Can be selected randomly] *4 Holds setting while SW1 is ON. 01 (NC) *1. With the terminal with input terminal selection [18 (RS)], NO/NC selection is fixed to [00 (NO)]. *2. When [C003] is [64 (EMR)], [C013] is fixed to [01 (NC)]. *3. If [18 (RS)] has been allocated to a multi-function input terminal (except for 3) other than terminal 1 before switch SW1 is set to "ON", the input terminal selection for the relevant terminal will be automatically changed to "no (no allocation)" by setting SW1 to "ON". This is done in order to prevent duplicated allocation of this function. Then, even if SW1 is reset to [OFF], the initial allocation cannot be restored. The User should Re-allocate the terminal function. Example) When the multi-function input terminal 2 [C002] is [18 (RS)], setting SW1 to [ON] changes the [C002] setting to [no (no allocation)]. [18 (RS)] will be allocated to the multi-function input terminal 1 [C001]. Then, even if SW1 is reset to [OFF], the multi-function input terminal 2 [C002] setting is [no (no allocation)], and the multi-function input terminal 1 [C001] setting is [18 (RS)]. *4. Input terminal selection [64 (EMR)] cannot be selected with the Digital Operator. When slide switch SW1 is set to [ON], this function will be automatically allocated. 2-10 2 Design SW1 OFF Emergency shutoff: Disabled (factory default) Multi-function input terminal 1 2-2 Wiring *5. Once slide switch SW1 is set to [ON], allocation of multi-function input terminals 1 and 3 will not be restored, even if SW1 is reset to [OFF] afterward. Re-allocate the terminal function. Design 2 Slide switch SW1 ON Slide lever (factory default: OFF) OFF ON Wiring the Main Circuit Terminals Main Power Supply Input Terminals (R/L1, S/L2, T/L3) • Use an earth leakage breaker for circuit (wiring) protection between the power supply and the main power supply terminals (R/L1, S/L2, T/L3). • An earth leakage breaker may malfunction due to the effect of high frequency. Use an earth leakage breaker with a large high-frequency sensitivity current rating. • If the Inverter protection function is activated, a malfunction or accident may have occurred to your system. Connect a magnetic contactor to turn off the Inverter power supply. • Do not start or stop the Inverter by switching ON/OFF the magnetic contactor connected on the Inverter power supply input (primary) side and output (secondary) side. To start or stop the Inverter via an external signal, use the operation command (FW or RV) on the control circuit terminal block. • This Inverter uses a 3-phase power supply. A single-phase power supply cannot be used. • Do not use this Inverter with a phase loss power input. Doing so may damage the Inverter. By factory default, the phase loss input protection is disabled. If a phase of power supply input is interrupted, the Inverter reverts to the following status: R/L1-phase or T/L3-phase is inter- The Inverter does not operate. rupted: S/L2-phase is interrupted: The Inverter reverts to single-phase operation, causing a trip (due to undervoltage, overcurrent, etc.) or damage to the Inverter. Even if the power input is under a phase loss condition, the internal capacitor is charged with voltage, causing an electric shock or injury. When changing the cable connections, refer to the instructions on page 2-1. 2-11 2-2 Wiring • In the following cases, the internal converter module may be damaged. Use caution to avoid them: Imbalance of power supply voltage is 3% or more. Power supply capacity is ten times or more than the Inverter capacity, and also 500 kVA or more. Rapid change in power supply voltage. 2 Example) When several Inverters are connected with a short bus. When the phase advance capacitor is turned on/off. Inverter Output Terminals (U/T1, V/T2, W/T3) • For connection of the output terminal, use the applicable cable or a cable with a larger diameter. Otherwise, the output voltage between the Inverter and the motor may drop. Particularly during low-frequency output, a voltage drop occurs with the cable, resulting in motor torque reduction. • Do not mount a phase advance capacitor or surge absorber. These devices cause the Inverter to trip, or may cause damage to the capacitor or surge absorber. • If the cable length exceeds 20 m (particularly, with 400-V class), a surge voltage may be generated at the motor terminal due to stray capacitance or inductance of the cable, causing the motor to burn out. • To connect several motors, provide a thermal relay for each. • The RC value of each thermal relay should be 1.1 times of the motor rated current. The relay may trip easily depending on the cable length. In this case, connect an AC reactor to the Inverter output. DC Reactor Connection Terminal (PD/+1, P/+) • This terminal is used to connect the optional DC reactor for power factor improvement. By factory default, a short-circuit bar has been connected between the terminals PD/+1 and P/+. Before connecting the DC reactor, remove this short-circuit bar. • The length of the DC reactor connection cable should be 5 m or less. If the DC reactor is not used, do not remove the short-circuit bar. If you remove the short-circuit bar without connecting the DC reactor, no power is supplied to the Inverter main circuit, disabling operation. External Braking Resistor Connection Terminal (P/+, RB)/Regenerative Braking Unit Connection Terminal (P/+, N/-) • The Inverters with 22 kW or lower capacity incorporate a regenerative braking circuit. To improve braking capability, mount the optional external braking resistor to this terminal. Do not mount a resistor whose resistance is lower than the specified value. Doing so may damage the regenerative braking circuit. • The Inverters with 30 kW or higher capacity do not incorporate a regenerative braking circuit. To improve braking capability, the optional regenerative braking unit and braking resistor are required. In this case, connect the regenerative braking unit terminals (+, -) to the Inverter terminals (P/+, N/-). • The cable length should be 5 m or less. Twist the two wires. • Do not connect any device other than the optional regenerative braking unit or external braking resistor to this terminal. 2-12 Design • Do not turn power on/off more than once every 3 minutes. Doing so may damage the Inverter. 2-2 Wiring Ground Terminal (G ) • To prevent electric shock, be sure to ground the Inverter and the motor. • According to the Electric Apparatus Engineering Regulations, the 200-V class Inverter should be connected to the grounding electrodes under type-D grounding conditions (conventional type 3 grounding: ground resistance 100  or less), the 400-V class Inverter should be connected to the grounding electrodes under type-C grounding conditions (conventional special type 3 grounding: ground resistance 10  or less). • For the ground cable, use the applicable cable or a cable with a larger diameter. Make the cable length as short as possible. • When several Inverters are connected, the ground cable must not be connected across several Inverters, and must not be looped. Otherwise, the Inverters may malfunction. Design 2 Inverter Inverter Inverter Inverter Inverter Inverter Your ground bolt Installing Screws in the Main Circuit Terminal Block • For the main circuit terminal blocks of 3G3RX-A2055/-A2075/-A4055/-A4075, be sure to install the terminal block screw washers with their grooved sides aligned vertically, as shown below. Not doing so may result in a contact failure or fire. (Intended terminals: R/L1, S/L2, T/L3, PD/+1, P/+, N/-, U/T1, V/T2, W/T3, RB) Terminal block screw washer 2-13 2-2 Wiring  Arrangement of Main Circuit Terminals The terminal arrangement on the Inverter main circuit terminal block is shown below. Terminal arrangement Ro Applicable model R/L1 S/L2 T/L3 U/T1 PD/+1 P/+ N/- RB V/T2 W/T3 G G 2 To Design CHARGE LED indicator When not using the DC reactor, keep the PD/+1 - P/+ short-circuit bar attached. PD/+1 - P/+ short-circuit bar [EMC filter function switching method] In order to enable the EMC filter function, set up the plug inserted into the filter enable pin (J61) and filter disable pin (J62) as shown in the table below. Confirm that electrical power has been disconnected before performing this setup. Not doing so may result in electric shock. Also, use with the plug inserted. Dummy plug (green) Filter enable pin (J61) Short plug 3G3RX-A2004 to A2037 3G3RX-A4004 to A4037 Ro,To: M4 Ground terminal: M4 Others: M4 Filter disable pin (J62) EMC filter disabled Filter enable pin (J61) Dummy plug (green) EMC filter enabled (factory default) Short plug Filter disable pin (J62) Short plug Dummy plug (green) Ro CHARGE LED indicator R/L1 S/L2 T/L3 PD/+1 P/+ G Ground terminal with short-circuit bar (shaded area) for EMC filter function switching To RB N/- U/T1 V/T2 PD/+1 - P/+ short-circuit bar G W/T3 3G3RX-A2055, A2075 3G3RX-A4055, A4075 Ro,To: M4 Ground terminal: M5 Others: M5 When not using the DC reactor, keep the PD/+1 - P/+ short-circuit bar attached. [EMC filter function switching method] 3G3RX-A2110 3G3RX-A4110 Ro,To: M4 Ground terminal: M6 Others: M5 EMC filter enabled (factory default) EMC filter disabled 2-14 2-2 Wiring Terminal arrangement Applicable model Ro To CHARGE LED indicator RB 2 Design R/L1 S/L2 T/L3 PD/+1 P/+ N/- G U/T1 V/T2 PD/+1 - P/+ short-circuit bar Ground terminal with short-circuit bar (shaded area) for EMC filter function switching W/T3 G 3G3RX-A2150 to A2185 3G3RX-A4150 to A4220 Ro,To: M4 Ground terminal: M6 Others: M6 When not using the DC reactor, keep the PD/+1 - P/+ short-circuit bar attached. [EMC filter function switching method] 3G3RX-A2220 Ro,To: M4 Ground terminal: M6 Others: M8 EMC filter enabled (factory default) EMC filter disabled Ro CHARGE LED indicator 3G3RX-A2300 To G G R/L1 S/L2 T/L3 PD/+1 Ground terminal with short-circuit bar (shaded area) for EMC filter function switching P/+ N/- U/T1 V/T2 W/T3 PD/+1 - P/+ short-circuit bar When not using the DC reactor, keep the PD/+1 - P/+ short-circuit bar attached. [EMC filter function switching method] Ro, To: M4 Ground terminal: M6 Others: M8 3G3RX-A4300 Ro,To: M4 Ground terminal: M6 Others: M6 3G3RX-A2370 3G3RX-A4370 Ro,To: M4 Ground terminal: M8 Others: M8 EMC filter enabled (factory default) 2-15 EMC filter disabled 2-2 Wiring Terminal arrangement Applicable model Ro CHARGE LED indicator To 2 G R/L1 T/L3 PD/+1 P/+ N/- PD/+1-P/+ short-circuit bar U/T1 V/T2 W/T3 G Ground terminal with short-circuit bar (shaded area) for EMC filter function switching When not using the DC reactor, keep the PD/+1-P/+ short-circuit bar attached. 3G3RX-A2450 3G3RX-A4450 3G3RX-A4550 [EMC filter function switching method] Ro,To: M4 Ground terminal: M8 Others: M8 EMC filter enabled (factory default) EMC filter disabled Ro CHARGE LED indicator R/L1 G S/L2 T/L3 Design G S/L2 PD/+1 P/+ PD/+1 - P/+ short-circuit bar When not using the DC reactor, keep the PD/+1 - P/+ short-circuit bar attached. N/- G To U/T1 V/T2 G Ground terminal with short-circuit bar (shaded area) for EMC filter function switching 3G3RX-A2550 Ro,To: M4 Ground terminal: M8 Others: M10 [EMC filter function switching method] EMC filter enabled (factory default) W/T3 EMC filter disabled 2-16 2-2 Wiring Recommended Cable Size, Wiring Device and Crimp Terminal For Inverter wiring, crimp terminal and terminal screw tightening torque, refer to the table below. Motor output (kW) Applicable Inverter model 0.4 3G3RX-A2004 1.25 1.25 1.25 M4 1.25-4 1.2 (max.1.8) 30 A 0.75 3G3RX-A2007 1.25 1.25 1.25 M4 1.25-4 1.2 (max.1.8) 30 A 1.5 3G3RX-A2015 2 2 2 M4 2-4 1.2 (max.1.8) 2.2 3G3RX-A2022 2 2 2 M4 2-4 1.2 (max.1.8) 3.7 3G3RX-A2037 3.5 3.5 3.5 M4 3.5-4 1.2 (max.1.8) 30 A 5.5 3G3RX-A2055 5.5 5.5 5.5 M5 R5.5-5 2.4 (4.0 max.) 100 A 7.5 3G3RX-A2075 8 8 8 M5 R8-5 2.4 (4.0 max.) 100 A 11 3G3RX-A2110 14 14 14 M6 R14-6 4.0 (4.4 max.) 15 3G3RX-A2150 22 22 22 M6 22-6 4.5 (4.9 max.) 18.5 3G3RX-A2185 30 22 30 M6 38-6 4.5 (4.9 max.) 22 3G3RX-A2220 38 30 38 M8 38-8 8.1 (8.8 max.) 30 3G3RX-A2300 60 (22 × 2) 30  M8 60-8 8.1 (8.8 max.) 37 3G3RX-A2370 100 (38 × 2) 38  M8 *1 100-8 8.1 (20.0 max.) 45 3G3RX-A2450 100 (38 × 2) 38  M8 *1 100-8 8.1 (20.0 max.) 55 3G3RX-A2550 150 (60 × 2) 60  M10 150-10 19.6 (22.0 max.) 2-17 Terminal screw size Crimp terminal Tightening torque N•m Circuit breaker or fuse Fuse (Type J) Ground cable (mm2) External braking resistor between PD/+1 and RB (mm2) Fuse (Type J) or Inverse time circuit breaker 200-V class Design 2 Power cable (mm2) R, S, T, U, V, W, PD/+1, P/+, N/- Applicable device Earth leakage breaker (ELB) 30 A 30 A 100 A 125 A 125 A 125 A 225 A 225 A 250 A 300 A 2-2 Wiring Applicable Inverter model Ground cable (mm2) External braking resistor between PD/+1 and RB (mm2) Terminal screw size Crimp terminal Tightening torque N•m Circuit breaker or fuse Applicable device Earth leakage breaker (ELB) 3G3RX-A4004 1.25 1.25 1.25 M4 1.25-4 1.2 (max.1.8) 20 A 0.75 3G3RX-A4007 1.25 1.25 1.25 M4 1.25-4 1.2 (max.1.8) 20 A 1.5 3G3RX-A4015 2 2 2 M4 2-4 1.2 (max.1.8) 2.2 3G3RX-A4022 2 2 2 M4 2-4 1.2 (max.1.8) 4.0 3G3RX-A4040 2 2 2 M4 2-4 1.2 (max.1.8) 20 A 5.5 3G3RX-A4055 3.5 3.5 3.5 M5 R2-5 2.4 (4.0 max.) 40 A 7.5 3G3RX-A4075 3.5 3.5 3.5 M5 3.5-5 2.4 (4.0 max.) 40 A 11 3G3RX-A4110 5.5 5.5 5.5 M6 R5.5-6 4.0 (4.4 max.) 40 A 15 3G3RX-A4150 8 8 8 M6 8-6 4.5 (4.9 max.) 75 A 18.5 3G3RX-A4185 14 14 14 M6 14-6 4.5 (4.9 max.) 75 A 22 3G3RX-A4220 14 14 14 M6 14-6 4.5 (4.9 max.) 30 3G3RX-A4300 22 22 - M6 22-6 4.5 (4.9 max.) 37 3G3RX-A4370 38 22  M8 *1 38-8 8.1 (20.0 max.) 45 3G3RX-A4450 38 22  M8 *1 38-8 8.1 (20.0 max.) 55 3G3RX-A4550 60 30  M8 *1 R60-8 8.1 (20.0 max.) 150 A 75 3G3RX-B4750 100 (38 x 2) 38  M10 *1 100-10 20.0 (22.0 max.) 225 A 90 3G3RX-B4900 100 (38 x 2) 38  M10 *1 100-10 20.0 (22.0 max.) 225 A 110 3G3RX-B411K 150 (38 x 2) 60  M10 *1 150-10 20.0 (35.0 max.) 300 A 132 3G3RX-B413K 80 x 2 80  M10 *1 80-10 20.0 (35.0 max.) 350 A Inverse time circuit Breaker Fuse (Type J) 0.4 20 A 20 A 75 A 100 A 100 A 150 A *1. When the cable is connected without using the crimp terminal (bare wires), use the square washer included with the product. Note: The cable size is based on the HIV cable (75C heat resistance). 2-18 2 Design 400-V class Motor output (kW) Power cable (mm2) R, S, T, U, V, W, PD/+1, P/+, N/- 2-2 Wiring  Connection for Separating Inverter Control Circuit Power Supply from Main Power Supply If the Inverter protection circuit is activated to turn off the magnetic contactor of the Inverter input power supply, the power to the Inverter control circuit is also turned off, and the alarm signal cannot be kept on. If the alarm signal must be kept on, use control circuit power supply terminals Ro and To. Connect control circuit power supply terminals Ro and To to the primary circuit of the magnetic contactor according to the following procedure. 2 Design (Connection method) Incoming electricity specifications 200-V class: 200 to 240 V (+10%, -15%) 50, 60 Hz ±5% (282 to 339 V DC) 400-V class: 380 to 480 V (+10%, -15%) 50, 60 Hz ±5% (537 to 678 V DC) (1) Disconnect the connected wire. (2) Disconnect the J51 connector. (3) Connect the control circuit power cable to the control circuit power supply terminal block. * To separate the control circuit power supply (Ro, To) from the main circuit power supply (R/L1, S/ L2, T/L3), observe the following instructions: • For wiring between terminals Ro and To (terminal screw size: M4), use a cable of 1.25 mm2 or more. • Connect a 3 A fuse to the control circuit power supply cable. • If the control circuit power supply (Ro, To) is turned on before the main circuit power supply (R/L1, S/L2, T/L3), ground fault detection at power-on is disabled. • To use a DC power supply for the control circuit power supply (Ro, To), set the multi-function output terminal contact selection (C031 to C036) for the multi-function output terminals (11 to 15) and relay output terminals (AL2, AL1, AL0) to "00". If the multi-function output terminal contact selection is set to "01", the output signal may chatter when the DC power supply is turned off. • Tightening torque for terminals Ro and To M4: 1.2 N•m (1.4 max.) 2-19 2-2 Wiring Wiring Control Circuit Terminals • Terminals L and CM1 are insulated from each other via the input and output signal common terminals. Do not short-circuit or ground these common terminals. Do not ground these common terminals via external equipment. (Check the external equipment ground conditions.) 2 • For wiring the control circuit terminals, use twisted shielded cables (recommended size: 0.75 mm2), and connect the shielded cable to each common terminal. • Separate the control circuit terminal connection cables from the main circuit cable (power cable) and the relay control circuit cable. • For the connection of the TH (thermistor input) terminal, twist cables with the terminal CM1 individually, and separate them from other PLC common cables. Since a weak current flows through the thermistor, the thermistor connection cable must be separated from the main circuit cable (power cable). The thermistor connection cable should be 20 m or less. TH FW 8 PLC CM1 CM1 6 7 PLC 5 4 Thermistor • To use a relay for the multi-function output terminal, connect a surge-absorbing diode in parallel with the coil. • Do not short-circuit the analog power supply terminals (between H and L) and/or the interface power supply terminals (between P24 and CM1). Doing so may result in failure of the Inverter. Arrangement of the Control Circuit Terminal Block H L O O2 OI AM AMI FM P24 TH PLC FW 8 CM1 Terminal screw size M3 CM1 7 6 5 3 4 1 2 15 14 CM2 13 12 11 AL0 AL1 AL2 Tightening torque 0.7 N·m (0.8 max.)  Selecting the Input Control Logic By factory default the terminal FW and the multi-function input terminal are set to source logic (PNP). To change the input control logic to sink logic (PNP), remove the short-circuit bar between the terminals PLC and CM1 on the control circuit terminal block, and connect it between the terminals P24 and PLC. 2-20 Design • The control circuit terminal connection cables should be 20 m or less. 2-2 Wiring  Selecting the Sequence Input Method (Sink/Source Logic) When external power supply is used (Remove the short-circuit bar from the control terminal block.) When the Inverter's internal interface power supply is used 2 +V Sink logic Short-circuit bar PLC CM1 P24 PLC 24 V DC 24 V DC CM1 FW FW 8 8 COM COM Output unit etc. COM Source logic Output unit etc. Inverter COM P24 Short-circuit PLC bar CM1 DC24V Output unit etc. Inverter 24 V DC 24 V DC P24 PLC CM1 FW FW 8 8 0V Output unit etc. Inverter 0V Inverter  Selecting the Sequence Output Method (Sink/Source Logic) 11 12 COM 24 V DC Source logic CM2 Sink logic Design +V P24 24 V DC 11 12 CM2 Inverter 2-21 Inverter COM 24 V DC 2-2 Wiring Wiring the Digital Operator • The RX Series Inverter can be operated with the optional 3G3AX-OP01 or AX-OP05-E as well as the standard Digital Operator. • To use the Digital Operator apart from the Inverter body, place an order for the optional cable 3G3AX-CAJOP300-EE (3 m). • The optional cable should be 3 m or less. Using a cable longer than 3 m may cause malfunction. 2 Conforming to EC Directives Design Conforming Standards •EMC directive •Low-voltage directive EN 61800-3: 2004 EN 61800-5-1: 2007 Concept of Conformity EMC Directive OMRON products are the electrical devices incorporated and used in various machines or manufacturing equipment. For this reason, we make efforts to conform our products to their related EMC standards so that the machines or equipment which have incorporated our products should easily conform to the EMC standards. The RX models have conformed to the EMC directive EN 61800-3 by following the installation and wiring method as shown below. Your machines or equipment, however, vary in type, and in addition, EMC performance depends on the configuration, wiring, or location of the devices or control panels which incorporate the EC directive conforming products. This in turn does not allow us to confirm the condition and the conformity in which our products are used. Therefore, we appreciate confirmation of the final EMC conformity for the whole machine or equipment on your own. Wiring the Power Supply •Keep the ground cable as short as possible. •Keep the cable between the Inverter and the noise filter as short as possible. Connecting a Motor to the Inverter •When connecting a motor to the Inverter, be sure to use shield braided cables. •Keep the cables as short as possible. Low-voltage Directive The RX models have conformed to the EMC directive EN61800-5-1 by performing the machine installation and wiring as shown below. •The RX models are an open type device. Be sure to install it inside the control panel. •The power supply and voltage (SELV) with reinforced or double insulation should be used for wiring to the control circuit terminals. •To satisfy requirements of the LVD (low-voltage) directive, the Inverter must be protected with a molded case circuit breaker (MCCB) in case a short-circuiting accident occurs. Be sure to install a molded case circuit breaker (MCCB) on the power supply side of the Inverter. •Use one molded case circuit breaker (MCCB) per Inverter. •Use the crimp-type terminal with an insulation sleeve to connect to the main circuit terminals. 2-22 2-2 Wiring EMC Filters Warnings and Instructions •The 3G3RX frequency inverters meet the limits of EN61800-3, C1/C2/C3, for radiated interference, if the specified line filter is used and installation is performed according to our instructions, and internal line filter is disabled. •The motor cable should be kept as short as possible in order to avoid electromagnetic emission as well as capacitive currents. The quick voltage changes of the OMRON inverter series cause capacitive currents through the motor cable stray capacitances. The cable length increases the capacitive current and electromagnetic emission. It is recommended that the motor cable length does not exceed 50m in any case, also depending on the inverter power range. It is recommended to install output AC-Reactors (motor chokes) if the cable length exceeds 50m. •The EMC filters contain capacitors between the phases and the phases to ground as well as discharging resistors. After switching off the line voltage you should wait a minimum of 60 seconds before removing protective covers or touching terminals to avoid electric shock! •The protective conductor connection between filter and drive is recommended without interruptions such as plug or contactors. If power plug or contactor become necessary they should be of the highest quality to provide neligible losses. •The use of ground fault monitoring devices is not recommended. Should they be compulsory in certain applications for safety reasons, you should choose monitoring devices which are suited for DC-, AC- and HF- ground currents. Standard ground monitoring devices may fail due to the switching nature of the inverter control. •The line filters have been developed for use in grounded systems. Use in ungrounded systems is not recommended. Design 2 If installed according to the following directions indicated in this section, the frequency inverter comply with the following standards: Emissions: EN 61800-3 (EN 55011 group 1, Category C1/C2/C3 [Class B/A]) Immunity: EN61800-3, industrial environments EMC compliant Installation of Drive Systems Introduction This document describes the electromagnetically compatible setup of your drive system with OMRON 3G3RX series inverters. (Electro Magnetic Compatibility = EMC). Read this information carefully and follow the instructions. If necessary, provide this information to third parties. HF interference results from rapid switching of electric currents and voltages. All AC, DC and servo drives very rapidly switch large currents and voltages in the process to supply connected electric motors. They become major sources of interference, generating both line-conducted and radiated interference. The additional use of line filters, also called interference suppression filters, and installation in a metal housing or a switch cabinet further improve the existing interference immunity. For the best possible damping of interference, special line filters have been developed which guarantee you easy assembly and installation along with the necessary electrical reliability. However, effective EMC countermeasures is only ensured if the suitable filter is selected for the particular drive and installed in accordance with these EMC recommendations. Selection of line filter to reduce line-conducted interference To reduce line-conducted interference, use the appropriate line filter for each frequency inverter. The below table show you a list of the available line filters for OMRON 3G3RX frequency inverter. The line filters up to 46A (200V class) or 58A (400V class) rated current are built in footprint style, they are fitted behind the respective frequency inverter, and thus require no additional surface space for installation. These filters are intended for installation in switch cabinets as standard. Vertical mounting next to the frequency inverter is also possible. The line filters from 64A (200V class) or 75A (400V class) rated current are built only in booktype style, and can be installed beside the frequency inverter. 2-23 2-2 Wiring Voltage 3 x 200V Inverter model 3G3RX-A2004 Listed filter Voltage AX-FIR2018-RE 3 x 400V Inverter model 3G3RX-A4004 3G3RX-A4007 3G3RX-A2015 3G3RX-A4015 3G3RX-A2022 3G3RX-A4022 3G3RX-A2037 3G3RX-A4040 3G3RX-A2055 AX-FIR2053-RE 3G3RX-A4055 3G3RX-A2075 3G3RX-A4075 3G3RX-A2110 3G3RX-A4110 3G3RX-A2150 AX-FIR2110-RE 3G3RX-A4150 3G3RX-A2185 3G3RX-A4185 3G3RX-A2220 3G3RX-A4220 AX-FIR3010-RE 2 AX-FIR3030-RE AX-FIR3053-RE 3G3RX-A2300 AX-FIR2145-RE 3G3RX-A4300 AX-FIR3064-RE 3G3RX-A2370 AX-FIR3250-RE 3G3RX-A4370 AX-FIR3100-RE 3G3RX-A4450 AX-FIR3130-RE 3G3RX-A2450 3G3RX-A2550 AX-FIR3320-RE 3G3RX-A4550 3G3RX-B4750 AX-FIR3250-RE 3G3RX-B4900 3G3RX-B411K AX-FIR3320-RE 3G3RX-B413K Filter installation The connecting cable between filter and frequency inverter must be as short as possible and laid separate from other cables/lines. As user you must ensure that the HF impedance between frequency inverter, filter and ground is a small as possible: Make sure that the connections are metallic and have the largest possible areas. Remove paint and insulating material between the individual mounting points. Use conductive contact grease as anticorrosive. Anodized and yellow-chromated surfaces, e.g. cable/standard-section rail, screws, etc., have a large HF-impedance, although sometimes could be confused with uncoated surfaces. Single grounding point: Ensure that the ground terminal (PE) of the filter is grounded to the same point or backplate like the ground terminal (PE) of the frequency inverter. An HF ground connection via metal contact between the housings of the filter and the frequency inverter, or solely via cable shield, is not permitted as protective conductor connection. The filter must be solidly and permanently connected with the ground potential so as to avoid the danger of electric shock upon touching the filter if a fault occurs. The metallic backplate of the control cabinet accounts as a single connection point (given the advice about coatings influence.) 2-24 Design 3G3RX-A2007 Listed filter 2-2 Wiring You can achieve highest filter installation quality by considering: Lowest impedance to ground: Connecting it with a grounding conductor of the lowest impedance or parallel/multiple short ground connections if not possible. The cross section of each single protective conductor terminal must be designed for the required nominal load. 2 Design Avoid ground loops: Conductor loops act like antennas, especially when the encompass large areas. Consequently: (1) Avoid unnecessary conductor loops and (2) Avoid parallel arrengement of "clean" and interference-prone conductors over longer distances. Use EMC filters only in grounded systems: The line filters have been developed for use in grounded systems. Use of the line filters in ungrounded systems or locations without proper ground quality is not recommended, beacuse in these applications: (1) Low current to ground increases, (2) The effect of the filter is reduced and (3) The amount of line-conducted and radiated interference increases in proportion to elementary frequency in frequency inverter. Consider motor cable length: The amount of line-conducted interference also increases as motor cable length increases. Output chokes may be required to countermeasure this effect. Disconnect internal RFI filter: Always when using external mount EMC filter make sure internal filter is disabled (figure corresponds to a 400V, 55kW case.) Minimizing radiated interference The 3G3RX frequency inverters meet the limits of EN61800-3, C1/C2/C3, for radiated interference, if the specified line filter is used and installation is performed according to our instructions, and internal line filter is disabled. Installing inverters only with integrated filters will achieve a limited C3 class category, of application in a limited range of systems, and with limited cable lengths and allowable carrier frequencies. 2-25 2-2 Wiring Achievable line conducted interference limits classes: Test Comment EN61800-3: 2004 Conducted emissions Category C1/C2 25m motor cable Pass EN61800-3: 2004 Conducted emissions Category C2 100m motor cable Pass EN61800-3: 2004 Radiated emissions Category C1/C2 25m motor cable Pass EN61800-3: 2004 Radiated emissions Category C2 100m motor cable Pass 2 Design Test standard Maximizing immunity. Control and signal lines Using EMC compliant cables for control signals: To ensure reliable operation of the frequency inverter, analog and digital control lines (encoder connection, all analog inputs, the serial interfaces, etc.) should be laid shielded. You should allow the effective shielding surface to remain as large as possible, i.e., do not move the shield further away than absolutely necessary. As a general rule, the shield has to be applied on both sides on PE, unless differently stated in the device manufacturers documentation. As a basic principle, the shielding of these lines should not be interrupted. Using this shielding can reduce the interference coupled into and out of the cable. The effectiveness of the shielding heavily depends on the construction and the material of the shielding. The screening effectiveness can be characterized by the so called transfer impedance. This effectiveness or performance can be improved by keeping the transfer impedance as low as possible. The transfer impedance is mainly affected by the following variables: •The cable covering, which is the cable area actually covered by the shielding. It is normally indicated as a percentage value and should be at least 85%. •The shielding’s design. Possible design alternatives are braided cables or shieldings made of metal conduit. These two types should be preferred when shielding is to be implemented. •The contact (or transition) resistance between the individual stranded conductors of the shielding. The performance of the shielding improves if the resistance is kept as low as possible. The following diagram shows the transfer impedance for various cable types. By comparing the cables individual design, the shielding effectiveness can be estimated and a suitable cable be chosen. 2-26 2-2 Wiring Design 2 Controller signal shields connect only to the ends: Single end or both but never midway. Control signals are not emitter, therefore the target is to create a coverage acting as antenna for the radiated emissions and drain them through single point to the ground... multiple shielding points at different potentials will create undesirable recirculating noise currents through ground loops. Ensure controller signals shield continuity: Control lines should remain without interruptions directly connecting signal source and signal reception. Should the case this is not possible (terminal box, plug connector or contactor / relay absolutely needed) then this elements should be selected of the highest quality and adequate for the signal to be managed (it is not the same a START/STOP 24VDC signal, than a 5VDC TTL encoder signal, than a 1Vpp sinusoidal signal of a SINCOS technology encoder from lower to highest sensivity to connection quality). As well, shield should be guaranteed continuity by passthrough contact, and never become grounded in this interruption point. We recommend high quality connectors that handle the shielding. twisted pairs (differential signals) control signal shield passthrough Encoders and sensors from the field: In this case follow the recommendations of the manufacturer of the sensor device. Most encoders and sensors with shielded cables will recommend 360º wrapping of the shield both at the sensing end and at the inverter end. For many of them, the shielding and grounding will be integral to the body of the sensor. 2-27 2-2 Wiring Direct connection as much as possible: Direct connection to the communications port of the control unit is mandatory to reduce connection impedance. This is very important, if there is a long distance between the system and you expect there can be different PE-Potential between the systems. Shield surface maximization: The effective shield area of these lines to remain as large as possible; i.e., do not move the shield of conductors further away than absolutely necessary. Avoid pigtails as much as possible. Avoid long unshielded cable runs. Control system in separate cabinet - Connect shield only one side: All analog and digital control lines are laid shielded. With distributed systems, if the communications control unit is not in the same cabinet and there is a distance between the systems, we recommend to put the screen only on the side of the frequency inverter, to avoid ground loops beacuse different PE potential. Distance between sensitive signals and interference sources: The distance between an interference source and an interference sink (interference-threatened device) essentially determines the effects of the emitted interference on the interference sink. The interference field emitted by the frequency inverter falls sharply with increasing distance. Please note that the emitted interference field (frequency range 30 MHz - 1 GHz) of a drive (drive system) is measured at a distance of 10 m in accordance with EN61800-3. Every device placed closer than 10 m to a source of interference will thus be impacted by appreciably higher interference amplitudes. For this reason, you should use only interference-free devices and mantain a minimum distance of 0.25 m from the drive. Devices which react sensitively to interference from electric and magnetic fields should be kept at least a distance of 0.25 m from the following components: •Frequency inverter •EMC input/output filters •Input or output reactors/transformer •Motor cable (even if shielded) •External braking resistor and its wiring (even if shielded) •AC/DC commutator motors, including any attached separate fans •DC intermediate circuit coupling/wiring (even if shielded) •Connected inductors like relays, contactors, solenoid valves, brakes (even if shielded) Avoid parallel runs of power and control lines: The parallel running in same conduit without proper distance of power lines (even shielded cables) and control lines is not allowed. This is source of most of EMC disturbance coupling. Control cables Motor power cable Crossing power lines and control lines: Should power and control lines have to cross unavoidably each other, then they should be layout with a 90º crossing. Motor power cable Control cables 2-28 Design Control system in the same cabinet - Connect shield in both sides, never midway: All analog and digital control lines are laid shielded. With compact systems, if the frequency inverter and the control unit area in the same control cabinet connected at the same PE-Potential, the screen should be connected on both sides of the cable with PE (potential is same). 2 2-2 Wiring If control system recommendations conflict with these in this section: Always follow additional recommendations of control system manufacturer. If these recommendations happen to conflict with those in this section is usually beacuse the control system has a different internal power and isolation structure. If the conflicting recommendation is to connect the shield to a propietary point other than PE (power ground point) in the control connector, please respect so, and DO NOT CONNECT THE SHIELD TO PE on the inverter side, only follow control system manufacturer recommendations (as those are done to maximize immunity for the characteristic control system structure). 2 Design Installing the motor cable If you use an EMC line filter or would like to observe certain limits of line-conducted interference, the motor cable which you use must be shielded. The shield is to be grounded on both sides, over a large area. For this purpose, turn the shield through 180º, for instance, and make large-area contact (360º) with the metal PG screw connections. Use only copper mesh cable (CV) with 85% coverage. Foil shields often have a higher coupling impedance than mesh shields and are therefore unsuitable. Some motors have terminal boxes and PG screw connections of plastic. In these cases. the shield should be connected on the motor side to the motor housing, with as large an area as possible, by means of a cable clamp. Some motors have a rubber gasket between terminal box and motor housing. Very often, the terminal boxes, and particularly the threads for the metal PG screw connections, are painted. Make sure there is always a good metallic connection between the shielding of the motor cable, the metal PG screw connection, the terminal box and the motor housing, and carefully remove this paint if necessary. The shielding should not be interrupted at any point in the cable. If the use of reactors, contactors, terminals or safety switches in the motor output is necessary, i.e., if the shield must be interrupted, then the unshielded section should be kept as small as possible. It is better to install the reactor, contactor, terminal or safety switch in a metal housing with as much HF damping as possible. The shield connection to the metal housing should again be made with the smallest possible HF impedance, as already described. Should no shielded motor cable be available, lay the unshielded cable in a metal tube having the best possible shielding effect, for example. The metal tube should have good HF contact with the frequency inverter and the motor housing, e.g., by means of appropriate clamping. Safety grounding always takes precedence over HF grounding. If, for example, a braking chopper / rheostat is to be connected to the DC intermediate circuit, then this connecting line, too, must be shielded. The shield is to be connected on both sides, with a large area (e.g. to the protective ground terminal of the rheostat). Follows EMC compliant installation for motor. 2-29 2-2 Wiring Shielding and grounding layout in control cabinets Observe the requeriments of European standard EN60204-1, "Electrical Equipment of Industrial Machinery". You get optimum EMC only if you properly arrange and mount the OMRON 3G3RX frequency inverter, the appropriate line filter, and the other equipment which might be necessary, on a metal mounting plate, in accordance with the following mounting instructions. The following figure shows a 3G3RX 400V 1.5kW inverter installed with a footprint filter, and some additional devices (ferrite to minimize high frequency emissions from motor cable and DC reactor to countermeasure harmonic distorsion effect in supply network). Design EMC filter HITACHI 3G3RX-A4015 R S T U V W (L1) (L2) (L3) (T1) (T2) (T3) PD P (+1) (+) N (-) RB G G Ferrite DC reactor Main Supply 2 To Motor 2-30 2-2 Wiring The following figure shows a 3G3RX 400V 55kW inverter installed with a booktype filter, and some additional devices (ferrite to minimize high frequency emissions from motor cable and DC reactor to countermeasure harmonic distorsion effect in supply network). 2 Design 3G3RX-A4550 H ITACH I EMC filter R S T PD P (L 1) (L2) (L3) (+1) (+) N U V W (-) (T1) (T2) (T3) Ferrite DC reactor Main Supply 2-31 To Motor 2-2 Wiring Additional notes Influence of motor cable length Multiple motor applications In multiple motor applications, i.e., a frequency inverter feeds several motors connected in parallel, you should try to minimize the effective cable capacity and/or the effective length of the shielded cable. You can achieve this by creating a neutral cross-connecting point from which you can supply all motors. Layout to be done so that the shielding is maintained over the entire length of the cable, if possible, or is only very briefly interrupted. It is better to install this neutral cross-connecting point in a metal housing with as much HF damping as possible. The shield connection from/to the metal housing should again be made with the smallest possible HF impedance, as already described. Influence of ground fault monitoring devices In the line filter, capacitors are placed between the phases and ground, which can cause larger charge currents to flow to ground when the filter is first switched on. The amount of this flow has already been minimized by constructional circuit details. Nevertheless, ground fault monitoring devices possibly present may be triggered. Ground currents with high-frequency components and DC components may also flow under normal operating conditions. If faults occur, large DC-carrying ground currents may flow, possibly preventing the ground fault monitoring device from responding. For this reason, the use of ground fault monitoring devices is not recommended. But should they be prescribed in certain applications for safety reasons, you should choose monitoring devices which are suited for DC, AC and HF ground currents. In addition, you should ensure that their responsiveness and time characteristics are adjustable, so that a disturbance is not immediately caused the first time the frequency inverter is switched on. Components susceptible to interference The following components must be classified as particularly susceptible to interference from electromagnetic fields. Special attention should therefore be paid to them during installation: •Sensors with analog output voltages (< 1 volt) •Load cells •Tractive force meters •Torque measuring hubs •Resistance thermometer PT100 •Thermoelements •Anemometers •Piezoelectric sensors •AM radios (only long and medium wave) •Video cameras and TV sets •Office PCs •Compacitive proximity switches and filling level sensors •Inductive proximity switches and metal detectors 2-32 2 Design Shielded motor cables have quite a high cable capacity towards ground, which increases linearly as cable length increases. A typical rule-of-thumb figure is 200 pF per meter of cable. But these figures vary among different types of cables and are also dependent on the current-carrying capacity. Long motor cables can give rise to the following: Frequency inverter and servo amplifiers give a pulse-width-modulated square-wave output voltage with quite steep slopes, which causes high reverse-charging currents in the table capacities towards ground. This reverse-charging current must be additionally supplied by the device. Unwanted switch-off due to overload may occur. •Long motor cables produce more line-conducted interference. •Long motor cables lead to the triggering of a ground fault monitoring device that may be present. •Long motor cables lead to thermal overload of the line filter due to the higher line-conducted interference. If a motor output choke of appropriate size is used, you have the following advantages: •It can counteract unwanted shut-off due to overload, described above. •The thermal load on the EMC line filter is reduced. 2-2 Wiring •Ripple control transmitters, baby talkers, etc., i.e. all communication devices which use low-voltage systems as transmission medium •Devices which do not comply with the pertinent EMC requirements Built-in filter specifications 3G3RX-E1F includes a embedded EMC filter. However, when using the inverter in Europe, you should comply with the following specifications and requirements to meet the EMC Directive and other standards in Europe: •Power supply requirements: a. Voltage fluctuation must be -15% to +10% or less. b. Voltage imbalance must be +/- 3% or less. c. Frequency variation must be +/- 4% or less. d. Total harmonic distortion (THD) of voltage must be +/- 10% or less. •Wiring requirements: a. A shielded wire (screened cable) must be used for motor wiring, and the length of the cable must be according to the following table. b. The carrier frequency must be set according to the following table to meet EMC requirements. c. The main circuit wiring must be separated from the control circuit wiring. •Environmental requirements: a. Ambient temperature must be within the range -10ºC to +40ºC. b. Relative humidity must be within the range 20% to 90% (non-condensing). c. Vibrations must be 5.9 m/s2 (0.6 G) (10 to 55 Hz) or less. (0.4 to 22 kW) 2.94 m/s2 (0.3 G) (10 to 55 Hz) or less. (30 to 132 kW) d. The inverter must be installed indoors (not exposed to corrosive gases and dust) at an altitude of 1000 m or less. Design 2 2-33 Model Cat. Cable length (m) Carrier frequency (kHz) Model Cat. Cable length (m) Carrier frequency (kHz) 3G3RX-A2004 C3 5 2.5 3G3RX-A4004 C3 5 2.5 3G3RX-A2007 C3 5 2.5 3G3RX-A4007 C3 5 2.5 3G3RX-A2015 C3 5 2.5 3G3RX-A4015 C3 5 2.5 3G3RX-A2022 C3 5 2.5 3G3RX-A4022 C3 5 2.5 3G3RX-A2037 C3 5 2.5 3G3RX-A4040 C3 5 2.5 3G3RX-A2055 C3 1 1 3G3RX-A4055 C3 1 2.5 3G3RX-A2075 C3 1 1 3G3RX-A4075 C3 1 2.5 3G3RX-A2110 C3 1 1 3G3RX-A4110 C3 1 2.5 3G3RX-A2150 C3 1 1 3G3RX-A4150 C3 1 2.5 3G3RX-A2185 C3 1 1 3G3RX-A4185 C3 1 2.5 3G3RX-A2220 C3 5 2.5 3G3RX-A4220 C3 1 2.5 3G3RX-A2300 C3 5 2.5 3G3RX-A4300 C3 1 2.5 3G3RX-A2370 C3 5 2.5 3G3RX-A4370 C3 1 2.5 3G3RX-A2450 C3 5 2.5 3G3RX-A4450 C3 5 2.5 3G3RX-A2550 C3 5 2.5 3G3RX-A4550 C3 5 2.5 3G3RX-A4750 C3 10 2.5 3G3RX-A4900 C3 10 2.5 3G3RX-B411K C3 10 2.5 3G3RX-B413K C3 10 2.5 Chapter 3 Operation 3-1 3-2 3-3 3-4 3-5 3-6 3-7 Operation Method ............................................ 3-3 LCD Display ...................................................... 3-4 Test Run Procedure ......................................... 3-5 Operation .......................................................... 3-6 Read/Write function and operation ................ 3-13 Test Run Operation.......................................... 3-14 Part Names and Descriptions of the Digital Operator ............................................................ 3-17 3-8 Parameter Transition ....................................... 3-19 3-9 Parameter List .................................................. 3-21 3Operation DANGER Do not change wiring and slide switches (SW1), put on or take off Digital Operator and optional devices, replace cooling fans while the input power is being supplied. Doing so may result in a serious injury due to an electric shock. Do not remove the terminal block cover during the power supply and 10 minutes after the power shutoff. Doing so may result in a serious injury due to an electric shock. 3 Operation Do not operate the Digital Operator or switches with wet hands. Doing so may result in a serious injury due to an electric shock. Inspection of the Inverter must be conducted after the power supply has been turned off. Not doing so may result in a serious injury due to an electric shock. The main power supply is not necessarily shut off even if the emergency shutoff function is activated. CAUTION Do not touch the Inverter fins, braking resistors and the motor, which become too hot during the power supply and for some time after the power shutoff. Doing so may result in a burn. Take safety precautions such as setting up a molded-case circuit breaker (MCCB) that matches the Inverter capacity on the power supply side. Not doing so might result in damage to property due to the short circuit of the load. Safety Information Operation and Adjustment •Be sure to confirm the permissible range of motors and machines before operation because the Inverter speed can be changed easily from low to high. •Provide a separate holding brake if necessary. 3-1 Precautions for Use Error Retry Function •Do not come close to the machine when using the error retry function because the machine may abruptly start when stopped by an alarm. •Be sure to confirm the RUN signal is turned off before resetting the alarm because the machine may abruptly start. 3 Non-Stop Function at Momentary Power Interruption •Do not come close to the machine when selecting restart in the non-stop function at momentary power interruption selection (b050) because the machine may abruptly start after the power is turned on. •Provide a separate emergency stop switch because the STOP key on the Digital Operator is valid only when function settings are performed. •When checking a signal with the main power supply applied, if a signal voltage is erroneously applied to the control input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal. 3-2 Operation Operation Stop Command 3-1 Operation Method 3-1 Operation Method This Inverter has the following operation methods that are selected by the RUN command/ frequency reference settings. The features and the requirements for each operation method are also given below:  To enter the RUN command/frequency reference via the Digital Operator This action operates the Inverter via a key sequence of the standard or optional Digital Operator. When operating the Inverter only via the Digital Operator, the Inverter does not need to be connected to the control circuit terminal block. Operation 3 HITACHI WARNING Digital Operator LOCAL REMOTE READ WRITE ESC FWD REV To enter the RUN command/frequency reference from the control circuit terminal block This action operates the Inverter by connecting the external signals (from the frequency setting device, starting switch, etc.) to the control circuit terminal block. The operation starts by turning ON the RUN command (FW, RV) while the input power supply is turned ON. Note: that the frequency can be set using a voltage signal or a current signal from the control circuit terminal block, which can be selected according to the system. For details, refer to "Control Circuit Terminal" (page 2-6). (Requirements for operation) • RUN command: Switch, Relay etc. • Frequency reference: External signal (e.g. 0 to 10 V DC, -10 to 10 V DC, 4 to 20 mA) HITACHI WARNING Digital Operator LOCAL REMOTE READ WRITE ESC FWD REV Control circuit terminal block H Frequency reference (FREQ adjuster) O P24 L RUN command and (switch) FW To enter the RUN command/frequency reference in a combination of Sources from the Digital Operator and the control circuit terminal block The RUN command/frequency reference sources can be selected individually from the Digital Operator as well as the control circuit terminal block. 3-3 3-2 LCD Display 3-2 LCD Display Backlight There are two backlight colors in the LCD display, white and orange. They reflect the state of the inverter as follows: 3 Contents White Normal (not related to inverter driving/stop) Orange Warning (Parameter mismatch) White Orange (Alternate blinking for one second) Trip (The same as ALARM LED) Operation Backlight Color Details of LCD Display The first line of LCD monitor always displays the Display Mode, the Motor Selected, the Inverter RUN Status and the Display Selection. D is play Mode M otor Selected Item Inv erter R U N Status Display Selection Content of Display Content MONITOR-A Monitor-A mode MONITOR-B Monitor-B mode FUNCTION Function mode TRIP Trip (error) mode WARNING Warning mode (Alarm) OPTION LCD Configuration Mode M1 Motor 1 (SET multifunction = OFF) M2 Motor 2 (SET multifunction = ON) STOP Stopped FWD Forward running REV Reverse running ALL Display all UTL Function individual display USR User setting display CMP Data compare display BAS Basic display Display Mode Motor selected Inverter RUN Status Display Selection (b037) 3-4 3-3 Test Run Procedure 3-3 Test Run Procedure Item 3 Reference page Installation and Mounting Install the Inverter according to the installation conditions. 2-1 • Make sure that the installation conditions are met. Wiring and Connection Operation Description Connect to the power supply and peripheral devices. 2-5 • Select peripheral devices that meet the specifications, and wire correctly. Power On Check the following before turning on the power. • Make sure that an appropriate power supply voltage is supplied and that the power input terminals (R/L1, S/L2, and T/L3) are wired correctly. • 3G3RX-A2: 3-phase 200 to 240 V AC • 3G3RX-A4: 3-phase 380 to 480 V AC • Make sure that the motor output terminals (U/T1, V/T2, and W/T3) are connected to the motor correctly. • Make sure that the control circuit terminals and the control device are wired correctly and that all control terminals are turned off. • Set the motor to no-load status (i.e., not connected to the mechanical system). • After checking the above, turn on the power. Display Status Check Make sure that there are no faults in the Inverter. • When the power is turned on normally, the display shows: • RUN LED indicator : OFF ALARM LED indicator : OFF • POWER LED indicator : ON • Data display : Displays the set value in d001. • If an error occurs, the error code is displayed on the data display. In this case, refer to "Chapter 5 Maintenance Operations" and make the necessary changes to remedy. Parameter Initialization Initialize the parameters. • Set parameter No. b084 to "2", and set parameter No. b180 to "1". Parameter Settings Set the parameters required for a test run. • Set the motor capacity selection (H003) and the motor pole number selection (H004). No-load Operation Start the no-load motor via the Digital Operator. • Display parameter No. F001, set the output frequency using the key, the key, and press the key to confirm the change. Then, press the rotate the motor. Actual Load Operation key and key to Connect the mechanical system and operate via the Digital Operator. • If there are no difficulties with the no-load operation, connect the mechanical system to the motor and operate via the Digital Operator. Operation 3-5 Refer to "Chapter 4 Functions", and set the necessary parameters. 3-4 Operation 3-4 Operation 1- Changing the Display Modes LCD digital operator has four display modes which can be changed from one to another by pressing the or key at Navigation level. Moreover, there are 3 other models called Read mode, Write mode and Option mode. In any display mode, it moves to Read mode or Write mode via key or key, and moves to Option mode after pressing , and at the same time. It returns to display modes via key. When pressing key at Navigation level, a cursor will appear on below layer. - LCD Navigation levels To move among the different Navigation levels press keys The outline of each mode is shown below. or . Monitor Mode A The "d" group inverter parameters and "F~U" group inverter parameter are displayed on the same screen in this mode. The content of "d" group parameter is displayed with big font characters. The function code such as "F001" and contents of "F~U" parameters are displayed, without the function name. Monitor Mode B (Monitor x 4) In this mode, four "d" group inverter parameters can be displayed at the same screen. The function codes of these parameters are not displayed. Function Mode (setting) In this mode, "F~U" group parameters can be displayed and set. Function code, function name, parameter content and parameter range are shown. Note: "d" group inverter parameter cannot be set and displayed in this mode. Trip Mode Trip information and warning information are displayed in this mode. With inverter trip or a warning happens, the trip screen will be displayed from any display modes. In Option Mode, Read Mode and Write Mode, the LED or WARNING LED will light up. 3-6 Operation Each mode has its own layers, where contents and parameters settings cannot be changed at Navigation level. 3 3-4 Operation 2- Option Mode 1- Please press , and key at the same time to enter into the OPTION MODE. The cursor will appear in the first row of the Option Mode menu. Use or key to move between the option Mode menu. To return to the navigator layer, press the key. Operation 3 2- Select the Language option and press the key. The cursor will appear in the Language option value. Use the or key to select the value to set. Press the key to store the new value. Press the key to cancel the new value. And then 3- The cursor will appear in the second row. (2. Date and Time). 4- Pressing the key, it enters to the Date and Time layer. Use the or key for moving between the Day, Month, Year, Hour, etc...data. When the cursor is over the selected data, pressing or key to change the value. The change will be stored after pressing the key. The settings available in this mode are: 1. Language 2. Date and Time 3. Read Lock 4. INV Type Select 5. R/W Storage Mode 6. Backlight Auto-off 7. Backlight Flicker 8. Operator Reset 9. Check Mode Use 3-7 or for moving between the Option Mode Menu. 3-4 Operation 3- Details of Option Mode Item Content Setting range Default Setting language Date and Time Setting Date and Time for the LCD digital operator Date: 2000/1/1-2099/12/31 Time: 00:00 - 23:59 Format 1-3 Read Lock Set "Read lock" disable to enable, in order to protect the parameter saved in LCD digital operator from being overwritten. 01: Enable 02: Disable 02 INV Type Select Please select the correct INV type using LCD digital operator. otherwise, "COM ERROR" will be displayed automatically. 01: Type 1 (MX2, LX, RX) 02: Type 2 (JX) 01 R/W Storage Mode Sets the number of parameter sets for READ/WRITE mode. 01: Single 02: Quad 02 Backlight Auto-Off When LCD digital operator remains without key operations for 1 minute, LCD backlight will be turned off. When a key is pressed it will turned on. The Backlight Auto-Off function does not work when trip happened. 01: Off 02: 1 minute 01 Backlight Flicker The Orange backlight will be enabled or disabled. 01: Enable 02: Disable 01 Operator Reset Use this function to return to default settings of LCD digital operator. The next items will be reset: 1- Language: English 2: Date and Time: 2009/01/01 THU 00:00 01: YES 3: Time format: 01:YY/MM/DD 02: NO 4: Read lock: Disable 5: R/W Storage Mode: Quad 6: Backlight Auto-Off: Off 7: Backlight Flicker: Enable After this, date and time setting is required. Check Mode Check if LED and key etc. are normal or not. Key&Led Check, LCD Check, EEPROM Check, RTC Check, Serial Loopback, Debug Mode, Firmware Version. 01 3 2009/01/01 00:00 1 02 - Note: Please do not execute the EEPROM check. Otherwise, the data (parameters/Drive program) saved in LCD digital operator will be erased.. 3-8 Operation Language 01: English 02: German 03: French 04: Spanish 05: Italian 06: Portuguese 07: Japanese 08: Chinese 09: Turkish 10: Russian 3-4 Operation 4- Monitor-A Display Mode 1- Please select monitor mode A by using the or key at the navigation layer. The cursor will be displayed in the Monitor-A pressing the key. Operation 3 2- After that, use the or displayed into the Monitor-A. key to select the function code to be Use or key to move the cursor to the function code (F001 in this case) and use the or key to change the function code. 3- Use the key to access to the function code value. With the or key the value can be changed. The changes will be stored after pressing the key or cancelled pressing the key. 3-9 3-4 Operation 5- Monitor-B Display Mode 1- Please select the Display Mode Monitor-B using the key at the navigation layer. or 3 Operation 2- After pressing the key the cursor will appear on the first row of the four "d" group inverter parameters. Use the or key to move between the four Monitor-B inverter parameters. 3- Pressing the key the cursor will appear on the function code of the "d" inverter parameters selected. Use the or key to select other function code. • Pressing the key, the function code is selected, and then displayed on the Monitor-B display Mode. • Pressing the key, the change will be cancelled. 3-10 3-4 Operation 6- Function Mode 1- Please select Function Mode by using the navigation level. or key at the Operation 3 2- Pressing the key the cursor will appear in the function code. Then use the , , or key to select the function that will be changed. 3- After that, pressing value. Use the or key the cursor will appear in the parameter key to select the value to be set. • To store the parameter value, press the • Pressing the 3-11 key. key, changes will be cancelled. 3-4 Operation 7- Trip Mode 1- Select the layer. or key to select trip mode at the navigation 3 Pressing 6 times the Operation 2- Pressing the key, the past trip information (6 trip errors) and the warning information (1 time), that are recorded on the inverter, will be displayed. Trip information is composed in two pages. For change from page 1 (P1) to page 2 (P2), press the or key. key, it will be displayed the Warning Mode. Note: When a trip happens, ALARM LED will be light on. Press the key to reset the inverter. 3-12 3-5 Read/Write function and operation 3-5 Read/Write function and operation LCD digital operator can read and save inverter parameter settings and copy them to another inverter. Specifically LCD digital operator can save four inverter’s parameter sets or one inverter’s parameter set and its Drive Programming. It can be selected via the R/W Storage Mode in the LCD configuration Option Mode. Operation 3 Note: If Read operation cannot be executed, please check the Read Lock option in the LCD configuration Option Mode. R/W Storage Mode - Single READ/WRITE function When the R/W Storage Mode is selected to "01: Single" (this is done in the LCD configuration: Option Mode), the function Read or Write is executed immediately after pressing or key. After pressing the key in any display mode, except Write mode and Option mode, the inverter’s parameter configuration are read and saved into LCD digital operator Drive Programming program will be transferred to the LCD digital operator automatically after parameter reading is finished. If the inverter supports Drive Programming function, it returns to the previous display after read function is completed. After pressing the key in any display mode except Read mode and Option mode, the parameter settings stored in LCD digital operator are transferred to the inverter. If the inverter supports Drive Programming, it will be transferred to the inverter automatically after the parameter copy is finished. It will return to the previous display after write function is completed. R/W Storage Mode - Quad READ function When the R/W storage mode is selected to 02: Quad option, it will be possible to handle four sets of inverter parameters or read/write an Drive Programming program independently. In this case, LCD digital operator can save four sets of inverter parameters or one set of inverter parameters and one Drive Programming program. Please note that one Drive Programming program takes up three sets of inverter parameters, which are No.2, No.3 and No.4. Note: Refer to "LCD Line Digital Operator User’s Manual" for more information. 3-13 3-6 Test Run Operation 3-6 Test Run Operation Power On Checkpoints Before Turning On the Power Power On •After checking the above, turn on the power. Display Status Check •When the power is turned on normally, the display shows: [Normal] RUN LED indicator (during RUN) : ON ALARM LED indicator POWER LED indicator : ON Data display : Displays the set value in d001 : OFF •If an error occurs, refer to "Chapter 5 Maintenance Operations" and make the necessary changes to remedy. [Fault] RUN LED indicator (during RUN) : OFF ALARM LED indicator : ON POWER LED indicator : ON Data display : An error code, such as "E01", is displayed. (The display varies depending on the type of error.) 3-14 3 Operation •Make sure that an appropriate power supply voltage is supplied and that the power input terminals (R/L1, S/L2, and T/L3) are wired correctly. 3G3RX- A2: 3-phase 200 to 240 V AC 3G3RX- A4: 3-phase 380 to 480 V AC •Make sure that the motor output terminals (U/T1, V/T2, and W/T3) are connected to the motor correctly. •Make sure that the control circuit terminals and the control device are wired correctly and that all control terminals are turned off. •Set the motor to no-load status (i.e., not connected to the mechanical system). 3-6 Test Run Operation Parameter Initialization •Initialize the parameters using the following procedure. •To initialize the parameters, set parameter b084 to "2" and parameter b180 to "1". Key sequence Display example MONITOR-A Description M1-STOP ALL d001 Output FQ 3 0.00Hz F001 0.00Hz FUNCTION Operation Power On M1-STOP ALL F001 Set Frequency (TM) Press the Prev. Page or Next Page key until function mode is displayed. 0 .00Hz [0.00 – 50.00] FUNCTION M1-STOP ALL F001 Set Frequency (TM) Press the Set key to enter function mode. 0 .00Hz [0.00 – 50.00] FUNCTION M1-STOP ALL b084 Initialize Mode 00:no With the Prev. Page, Next Page, Up and Down keys write the parameter b084. [00 – 04] FUNCTION M1-STOP ALL b084 Initialize Mode Press the Set key to enter b084 parameter. 00:no [00 – 04] FUNCTION M1-STOP ALL b084 Initialize Mode With the Prev. Page, Next Page, Up and Down keys put the parameter b084 to 2. 02:Parameters [00 – 04] FUNCTION M1-STOP ALL b084 Initialize Mode Press the Set key to change the parameter b084 to 2. 02:Parameters [00 – 04] FUNCTION M1-STOP ALL b180 Initialize trigger With the Prev. Page, Next Page, Up and Down keys write the parameter b180. 00:No action [00 – 01] FUNCTION M1-STOP ALL b180 Initialize trigger 00:No action [00 – 01] 3-15 Press the Set key to enter b180 parameter. 3-6 Test Run Operation Key sequence Display example FUNCTION Description M1-STOP ALL b180 Initialize trigger With the Prev. Page, Next Page, Up and Down keys put the parameter b180 to 1. 01:Initialize [00 – 01] Initial 01 IM-CT Press the Set key to change the parameter b180 to 1 and initialize parameters. 3 Operation No-load Operation •Start the no-load motor (i.e., not connected to the mechanical system) using the Digital Operator. Stopping the Motor •After completing the no-load operation, press the STOP/RESET key. The motor will stop. Actual Load Operation •After checking the operation with the motor in the no-load status, connect the mechanical system and operate with an actual load. Connecting the Mechanical System •After confirming that the motor has stopped completely, connect the mechanical system. •Be sure to tighten all the screws when fixing the motor axis and the mechanical system. Operation via the Digital Operator •Because a possible error may occur during operation, make sure that the STOP/RESET key on the Digital Operator is easily accessible. •Use the Digital Operator to operate the Inverter the same way as in no-load operation. Checking the Operating Status •After making sure that the operating direction is correct and that the Inverter is operating smoothly at a slow speed, increase the frequency reference. •By changing the frequency reference or the rotation direction, make sure that there is no vibration or abnormal sound from the motor. Make sure that the output current (output current monitor [d002]) is not excessive. 3-16 3-7 Part Names and Descriptions of the Digital Operator 3-7 Part Names and Descriptions of the Digital Operator 3 Part Names and Descriptions RUN LED WARNING LED POWER LED ALARM LED Operation HITACHI LCD display REMOTE LED OPERATION KEY KEY ENABLED LED WARNING Name Function POWER LED indicator Light on when the power is supplied to the LCD digital operator. RUN LED indicator Light on when the Inverter is runing. WARNING LED indicator Light on when set value is incorrect. ALARM LED indicator Light on when the Inverter trips. Remote LED Light on when the REMOTE key makes the compulsion operation function effective. It doesn’t light when the compulsion operation function is effective by input terminal OPE. (Press the key more than 2 seconds) Key Enabled LED Light on only when operation command is set in LCD digital operator. LCD Display LOCAL REMOTE key It changes from Local to Remote mode. Press the key during 2 seconds to change from Local to Remote or Remote to Local. When it is in Local the OPE led will be ON. Use Local to control the motor with LCD digital operator keys (Run Fwd, Run Rev and Stop/Reset). READ key It transfers inverter parameters to the LCD digital operator’s memory. WRITE key It copies one Parameter Set or a Parameter Set + Drive Programming saved in LCD digital operator to the inverter. ESC key SET key 3-17 Displays relevant data, such as frequency reference, output current, and set values. It returns to the above layer. It jumps to the below layer or stores the change introduces on the edit layer (after that it jumps to the above layer). 3-7 Part Names and Descriptions of the Digital Operator Name Function It is used to move up the cursor, it increases a function code in 1 or increases a parameter value. DOWN key It is used to move down the cursor, it decreases a function code in 1 or it decreases a value. PREV. PAGE key It is used to move the cursor to the left, or it moves to previous mode when the display is a navigation level. NEXT PAGE key It is used to move the cursor to the right, or it moves to the next mode when the display is a navigation level. FWD RUN key It is used to run forward the motor only when the operation command (A002) is reset in Digital operator. REV RUN key It is used to run reverse the motor only when the operation command (A002) is set in Digital operator. STOP/RESET key It is used to stop the motor or reset an alarm. It is also possible to invalidate the STOP key by B087 parameter. Besides it does not response when LCD digital operator is reading or writing the parameters from/to the inverter. Display System and Key Sequence of Each Code • This section explains the examples of typical operation (Basic display, Complete display) and the extended function mode U as a special operation. This operation can be performed when other display modes are selected. The display indicates the setting of "b038" when the power is turned on. For details, refer to "Initial Screen Selection (Initial Screen at Power-ON)" (page 4-56). When "b038 = 1" (factory default), output frequency monitor "d001" is displayed. Note: The Digital Operator display varies depending on the settings of display selection "b037", initial screen selection "b038", and user parameter automatic setting function selection "b039". For details, refer to "Display Selection" (page 4-53), "Initial Screen Selection (Initial Screen at Power-ON)" (page 4-56), "User Parameter Automatic Setting Function" (page 4-57). Item Display selection Initial screen selection (Power On) User parameter automatic setting function selection Function code b037 Data Description 00 Complete display (factory default) 01 Individual display of functions 02 User setting 03 Data comparison display 04 Basic display 000 Screen when the Enter key was pressed last 001-060 d001-d060 displayed b038 201 F001 (Output frequency setting/monitor) 202 Monitor screen 00 Disabled (factory default) 01 Enabled b039 3-18 3 Operation UP key 3-8 Parameter Transition 3-8 Parameter Transition Operation Example for Complete Display (Default: "b037 = 00") Displays all parameters. FUNCTION 3 FUNCTION M1-STOP ALL Operation A001 A001 A001 A153 01:Terminal [00 – 10] M1-STOP ALL b001 Restart mode UV b001 b180 00:TRIP [00 – 04] FUNCTION M1-STOP ALL C001 C001 Input [1] Function C169 01:RV [01 – no] FUNCTION M1-STOP ALL H001 H001 Auto-tuning select H073 00:OFF [00 – 02] FUNCTION M1-STOP ALL P001 Error mode OP1 card P001 P196 00:Trip [00 – 01] FUNCTION M1-STOP ALL U001 User function 1 no U001 U012 [d000 – no ] FUNCTION M1-STOP ALL F001 Set Frequency (TM) 0 .00Hz [0.00 – 50.00] 3-19 Frequency source 01:Terminal Frequency source FUNCTION M1-STOP ALL F001 F004 [00 – 10] 3-8 Parameter Transition  User Functions The extended function mode U is the parameter to optionally register (or automatically record) other extended function codes, and differs in operation from other extended function modes. A001 Extended function mode A A153 b001 3 Extended function mode B b180 Extended function mode C C169 FUNCTION M1-STOP ALL H001 U001 U001 Extended function mode H User function 1 no H073 U012 [d000 – no ] P001 Extended function mode P P196 d001 Monitor mode d104 F001 Function mode F004 3-20 Operation C001 3-9 Parameter List 3-9 Parameter List Monitor Mode (d) •The default setting displays "d001" at power-on. To select the optional display, change the setting in "b038". 3 Operation Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page d001 Output frequency monitor 0.00 to 400.00  Yes Hz 4-1 d002 Output current monitor 0.0 to 9999.0   A 4-1 d003 Rotation direction monitor FWD: Forward STOP: Stop REV: Reverse    4-1 d004 PID feedback value monitor 0.00 to 999000.00 (Enabled when the PID function is selected)    4-1    4-2    4-2 MONITOR-A d005 Multi-function input monitor M1-STOP ALL d005 Input H001 2 1 00:OFF MONITOR-A Multi-function output monitor FW, Multi-function input terminals 7, 2, 1: ON Multi-function input terminals 8, 6, 5, 4, 3: OFF HLHLLLLHH FW 8 7 6 5 4 3 d006 Example M1-STOP ALL d006 Output LLLLH H Example Multi-function output terminals 12, 11: ON Relay output terminal AL2, Multi-function output terminals 15, 14, 13: OFF AL2 15 14 13 12 11 H001 00:OFF d007 Output frequency monitor (after conversion) 0.00 to 39960.00 (Output frequency × Conversion factor of b086)  Yes  4-2 d008 Real frequency monitor -400.00 to 400.00   Hz 4-3 d009 Torque reference monitor -200 to 200   % 4-3 d010 Torque bias monitor -200 to 200   % 4-3 d012 Output torque monitor -200 to 200   % 4-3 d013 Output voltage monitor 0.0 to 600.0   V 4-3 d014 Input power monitor 0.0 to 999.9   W 4-4 d015 Power ON time monitor 0.0 to 999999.9    4-4 d016 Total RUN time 0 to 999999   h 4-4 d017 Power ON time monitor 0 to 999999   h 4-4 d018 Fin temperature monitor -020. to 200.0   C 4-4 3-21 3-9 Parameter List Parameter No. Function name d019 Motor temperature monitor Monitor or data range -020. to 200.0 MONITOR-A d022 Life assessment monitor M1-STOP ALL d022 Life(C/F) Default setting Changes during operation Unit Page   C 4-5    4-5 1: Main circuit board capacitor service life 2: Cooling fan rpm reduction LL 3 2 1 H001 00:OFF Program counter 0 to 1024     d024 Program number 0 to 9999     d025 Drive programming monitor (UM0) -2147483647 to 2147483647     d026 Drive programming monitor (UM1) -2147483647 to 2147483647     d027 Drive programming monitor (UM2) -2147483647 to 2147483647     d028 Pulse counter monitor 0 to 2147483647    4-6 d029 Position command monitor -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected.    4-6 d030 Current position monitor -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected.    4-6 4-137 d031 Clock Setting Data and Time for the LCD digital operator     d060 Inverter mode 00 to 01     d080 Fault frequency monitor 0 to 65535   Time 4-6 d081 Fault monitor 1 (Latest) d082 Fault monitor 2 d083 Fault monitor 3 d084 Fault monitor 4 d085 Fault monitor 5 d086 Fault monitor 6 d090 Warning monitor Warning code 0 to 385    4-7 d102 DC voltage monitor 0.0 to 999.9   V 4-7 d103 Regenerative braking load rate monitor 0.0 to 100.0   % 4-7 d104 Electronic thermal monitor 0.0 to 100.0   % 4-7 4-7 Error code (condition of occurrence) Output frequency [Hz]  Output current [A] Internal DC voltage [V] RUN time [h] ON time [h] 4-7    4-7 4-7 4-7 4-7 3-22 Operation d023 3-9 Parameter List Basic Function Mode (F) Parameter No. Operation 3 Function name Monitor or data range Default setting Changes during operation Unit Page F001 Output frequency setting/monitor 0.0/Starting frequency to 1st/2nd/3rd max. frequency 0.00 to 400.00 0.00 Yes Hz 4-8 F002 Acceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F202 * 2nd acceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F302 * 3rd acceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F003 Deceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F203 * 2nd deceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F303 * 3rd deceleration time 1 0.01 to 3600.00 10.00 Yes s 4-8 F004 Operator rotation direction selection 00: FWD (Forward) 01: REV (Reverse) 00 No  4-9 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-23 3-9 Parameter List Extended Function Mode Changes during operation Unit Page Frequency reference selection 00: VR (Digital Operator (FREQ adjuster)) (Enabled when 3G3AX-OP01 is used.) 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 06: Pulse train frequency 07: EzSQ (Drive programming) 10: (Math) Operation function result 01 No  4-10 4-144 A002 RUN command selection 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 01 No  4-11 A003 Base frequency 30 to Maximum frequency [A004] 50 A203 * 2nd set base frequency 30 to 2nd maximum frequency [A204] 50 A303 * 3rd set base frequency 30 to 3rd maximum frequency [A304] 50 A004 Maximum frequency A003 to 400 50 A204 * 2nd maximum frequency A203 to 400 50 A304 * 3rd maximum frequency A303 to 400 50 O/OI selection 00: [O]/[O2] Switches between O/OI via terminal AT 01: [O]/[O2] Switches between O/O2 via terminal AT 02: [O]/VR Switches between O/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 03: [OI]/VR Switches between OI/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 04: [O2]/VR Switches between O2/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) O2 selection 00: [O2] only 01: [O/OI-P] auxiliary frequency reference (not reversible) 02: [O/OI-PM] auxiliary frequency reference (reversible) 03: [OFF] O2 disabled Analog input, Others Basic setting A001 A005 A006 Function name Monitor or data range 4-11 4-112 No Hz 4-11 No Hz 4-12 00 No  4-12 03 No  4-12 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-24 3 Operation Default setting Parameter No. 3-9 Parameter List Multi-step speed, Jogging Operation 3 Analog input, Others Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page A011 O start frequency 0.00 to 400.00 0.00 No Hz A012 O end frequency 0.00 to 400.00 0.00 No Hz A013 O start ratio 0 to 100 0 No % A014 O end ratio 0 to 100 100 No % A015 O start selection 00: External start frequency (A011 set value) 01: 0 Hz 01 No  A016 O, O2, OI sampling 1 to 30 31 (with 500 ms filter ± 0.1 Hz hysteresis) 31 No  4-15 A017 Drive Programming (EzSQ) Selection 0: Disable 1: [PRG] start 2: Always ON 00 No   A019 Multi-step speed selection 00: Binary: 16-step selection with 4 terminals 01: Bit: 8-step selection with 7 terminals 00 No  4-16 A020 Multi-step speed reference 0 0.00 to Max. Frequency [A004] 6.00 Yes Hz A220 * 2nd multi-step speed reference 0 0.00 to Max. Frequency [A204] 6.00 Yes Hz A320 * 3rd multi-step speed 0.00 to Max. Frequency [A304] reference 0 6.00 Yes Hz 4-14 4-8 4-16 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-25 3-9 Parameter List Function name Monitor or data range Default setting A021 Multi-step speed reference 1 0.00 A022 Multi-step speed reference 2 0.00 A023 Multi-step speed reference 3 0.00 A024 Multi-step speed reference 4 0.00 A025 Multi-step speed reference 5 0.00 A026 Multi-step speed reference 6 0.00 A027 Multi-step speed reference 7 0.00 A028 Multi-step speed reference 8 A029 Multi-step speed reference 9 0.00 A030 Multi-step speed reference 10 0.00 A031 Multi-step speed reference 11 0.00 A032 Multi-step speed reference 12 0.00 A033 Multi-step speed reference 13 0.00 A034 Multi-step speed reference 14 0.00 A035 Multi-step speed reference 15 0.00 A038 Jogging frequency 0.00/Starting frequency to 9.99 Jogging stop selection 00: FRS (Free running on jogging stop/ Disabled in operation) 01: DEC (Deceleration stop on jogging stop/ Disabled in operation) 02: DB (DC injection braking on jogging stop/ Disabled in operation) 03: FRS (RUN) (Free running on jogging stop/Enabled in operation) 04: DEC (RUN) (Deceleration stop on jogging stop/Enabled in operation) 05: DB (RUN) (DC injection braking on jogging stop/Enabled in operation) A039 0.00/Starting frequency to Max. frequency Changes during operation Unit 3 Yes Hz 6.00 Yes Hz 04 No  0.00 Page Operation Multi-step speed, Jogging Parameter No. 4-16 4-18 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-26 3-9 Parameter List Parameter No. A041 3 Function name Torque boost selection Monitor or data range Default setting Changes during operation Unit No  Yes % Page 00 00: Manual torque boost 01: Automatic torque boost A241 * 2nd torque boost selection A042 Manual torque boost voltage A242 * 2nd manual torque boost voltage A342 * 3rd manual torque boost voltage 1.0 A043 Manual torque boost frequency 5.0 A243 * 2nd manual torque boost frequency A343 * 3rd manual torque boost frequency 00 1.0 0.0 to 20.0 1.0 V/f characteristics Operation 4-19 5.0 Yes % No  4-21 Yes % 4-24 Yes  5.0 V/f characteristics selection 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) A244 * 2nd V/f characteristics selection 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00 A344 * 3rd V/f characteristics selection 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 00 A045 Output voltage gain 20 to 100 100 A046 Automatic torque boost voltage compensation gain 0 to 255 100 A246 * 2nd automatic torque boost voltage compensation gain A047 Automatic torque boost slip compensation gain A247 * 2nd automatic torque boost slip compensation gain A044 V/f characteristics 0.0 to 50.0 0 to 255 00 100 4-20 0 to 255 100 Yes 0 to 255  100 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-27 3-9 Parameter List Upper/Lower limiter, Jump Upper/Lower limit, Jump Function name Monitor or data range Default setting Changes during operation Unit Page 01 No  4-24 4-112 0.50 No Hz 4-24 A051 DC injection braking selection 00: OFF (Disabled) 01: ON (Enabled) 02: ON (FQ) (Frequency control [A052 set value]) A052 DC injection braking frequency 0.00 to 400.00 A053 DC injection braking delay time 0.0 to 5.0 0.0 No s DC injection braking power 0 to 100 (0.4 to 55 kW) 50 No % A054 0 to 80 (75 to 132 kW) 40 No % 3 A055 DC injection braking time 0.0 to 60.0 0.5 No s A056 DC injection braking method selection 00: Edge operation 01: Level operation 01 No  A057 Startup DC injection braking power 0 to 100 (0.4 to 55 kW) 0 to 80 (75 to 132 kW) 0 No % A058 Startup DC injection braking time 0.0 to 60.0 0.0 No s DC injection braking carrier frequency 0.5 to 15.0 (0.4 to 55 kW) 5.0 No kHz A059 0.5 to 10.0 (75 to 132 kW) 3.0 No kHz No Hz A061 Frequency upper limit 0.00/Frequency lower limit to Max. frequency 0.00 A261 * 2nd frequency upper limit 0.00/2nd frequency lower limit to 2nd Max. frequency 0.00 A062 Frequency lower limit 0.00/Starting frequency to Frequency upper limit 0.00 A262 * 2nd frequency lower 0.00/Starting frequency to 2nd frequency limit upper limit 0.00 A063 Jump frequency 1 0.00 A064 Jump frequency width 1 0.50 A065 Jump frequency 2 4-24 4-28 No Hz No Hz 0.00 Jump frequency: 0.0 to 400.0 Jump frequency width: 0.0 to 10.0 A066 Jump frequency width 2 A067 Jump frequency 3 0.00 A068 Jump frequency width 3 0.50 A069 Acceleration stop frequency 0.00 to 400.00 0.00 No Hz A070 Acceleration stop time 0.0 to 60.0 0.0 No s 0.50 4-30 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-28 Operation DC injection braking DC injection braking Parameter No. 3-9 Parameter List Parameter No. PID control PID control Monitor or data range Default setting Changes during operation Unit A071 PID selection 00: OFF (Disabled) 01: ON (+) (Enabled) 02: ON (+/-) (Reverse output enabled) 00 No  A072 PID P gain 0.2 to 5.0 1.0 Yes  A073 PID I gain 0.0 to 3600.0 1.0 Yes s A074 PID D gain 0.00 to 100.00 0.00 Yes s A075 PID scale 0.01 to 99.99 1.00 No Time A076 PID feedback selection 00: OI 01: O 02: Modbus (RS485 communication) 03: Pulse (Pulse train frequency) 10: Math (Operation function output) Page 4-31 00 No  A077 00: OFF (Deviation = Target value Feedback value) Reverse PID function 01: ON (Deviation = Feedback value - Target value) 00 No  A078 PID output limit function 0.0 to 100.0 0.0 No % A079 PID feedforward selection 00: Disabled 01: O 02: OI 03: O2 00 No  A081 AVR selection 00: Always ON 01: Always OFF 02: OFF during deceleration 02 No  A082 AVR voltage selection 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 A085 RUN mode selection 00: Normal operation 01: Energy-saving operation 02: Automatic operation A086 Energy-saving response/accuracy adjustment AVR RUN mode, Acceleration/Deceleration functions Operation 3 Function name 4-31 4-35 200/ 400 No V 00 No  4-36 0.0 to 100.0 50.0 Yes  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-29 3-9 Parameter List Parameter No. Function name Monitor or data range Default setting A092 Acceleration time 2 10.00 A292 * 2nd acceleration time 2 10.00 A392 * 3rd acceleration time 2 Unit Yes s No  No Hz No Hz No  Page 10.00 0.01 to 3600.00 A093 Deceleration time 2 10.00 A293 * 2nd deceleration time 2 10.00 A393 * 3rd deceleration time 2 10.00 A094 2-step acceleration/ deceleration selection A294 * 2nd 2-step acceleration/ deceleration selection A095 2-step acceleration frequency A295 * 2nd 2-step acceleration frequency A096 2-step deceleration frequency A296 * 2nd 2-step deceleration frequency A097 Acceleration pattern selection A098 Deceleration pattern selection 00: 2CH-Terminal (Switched via multifunction input 09) 01: Preset FQ (Switched by setting) 02: FWD-REV (Enabled only when switching forward/reverse) 3 00 4-37 00 0.00 0.00 0.00 to 400.00 0.00 0.00 00: Line 01: S-curve 02: U-curve 03: inv. U curve 04: EL-S curve 01 4-38 01 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-30 Operation RUN mode, Acceleration/Deceleration functions Changes during operation 3-9 Parameter List A101 OI start frequency Operation frequency Accel/Decel External frequency adjustment External frequency adjustment Function name Acceleration/Deceleration Operation 3 Parameter No. Monitor or data range Default setting Changes during operation Unit 0.00 No Hz 0.00 No Hz Page 0.00 to 400.00 A102 OI end frequency A103 OI start ratio 0 to OI end ratio 20 No % A104 OI end ratio OI start ratio to 100 100 No % A105 OI start selection 00: Start FQ (Use OI start frequency [A101]) 01: 0 Hz 00 No  A111 O2 start frequency 0.00 No Hz 0.00 No Hz -100 No % 4-14 -400.00 to 400.00 A112 O2 end frequency A113 O2 start ratio -100 to O2 end ratio 4-15 A114 O2 end ratio O2 start ratio to 100 100 No % A131 Acceleration curve parameter 02 No  A132 Deceleration curve parameter 02 No  A141 Operation frequency input A setting 02 No  A142 Operation frequency input B setting 03 No  A143 Operator selection 00: ADD (Addition (A + B)) 01: SUB (Subtraction (A - B)) 02: MUL (Multiplication (A × B)) 00 No  A145 Frequency addition amount 0.00 to 99.99 100.0 to 400.0 0.00 No Hz A146 Frequency addition direction 00: ADD (Add A145 value to output frequency) 01: SUB (Subtract A145 value from output frequency) 00 No  A150 EL-S-curve ratio 1 during acceleration 0 to 50 10 No % A151 EL-S-curve ratio 2 during acceleration 0 to 50 10 No % A152 EL-S-curve ratio 1 during deceleration 0 to 50 10 No % A153 EL-S-curve ratio 2 during deceleration 0 to 50 10 No % 01 (small curve) to 10 (large curve) 00: Operator (Digital Operator (F001)) 01: VR (Digital Operator (FREQ adjuster)) (Enabled when 3G3AX-OP01 is used.) 02: O (Input O) 03: OI (Input OI) 04: Modbus (RS485 communication) 05: Option 1 06: Option 2 07: Pulse (Pulse train frequency) 4-38 4-41 4-41 4-39 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-31 3-9 Parameter List Momentary power interruption/Trip restart b001 Monitor or data range Default setting Changes during operation Unit 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) 00 No  Function name Retry selection Page 4-42 3 b002 Allowable momentary power interruption 0.3 to 25.0 time 1.0 No s b003 Retry wait time 0.3 to 100.0 1.0 No s b004 Momentary power interruption/ undervoltage trip during stop selection 00: OFF (Disabled) 01: ON (Enabled) 02: Decel-OFF (Disabled during stop and deceleration stop) 00 No  4-87 4-42 b005 Momentary power 00: 16 times interruption retry time 01: No limit selection 00 No  b006 Input phase loss protection selection 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-46 b007 Frequency matching lower limit frequency setting 0.00 to 400.00 0.00 No Hz 4-42 4-71 4-87 b008 Trip retry selection 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) 00 No  4-42 b009 Undervoltage retry time selection 00: 16 times 01: No limit 00 No  b010 Overvoltage/ overcurrent retry time 1 to 3 selection 3 No Time b011 Trip retry wait time 1.0 No s 0.3 to 100.0 4-42 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-32 Operation Momentary power interruption/Trip restart Parameter No. 3-9 Parameter List Parameter No. Electronic Thermal Operation 3 Monitor or data range Default setting Changes during operation Unit 0.20 × Rated current to 1.00 × Rated current Rated current No A Function name b012 Electronic thermal level b212 * 2nd electronic thermal level b312 * 3rd electronic thermal level b013 Electronic thermal characteristics selection b213 * 2nd electronic thermal characteristics selection b313 * 3rd electronic thermal characteristics selection b015 Free setting, electronic thermal frequency 1 b017 Free setting, electronic thermal frequency 2 b019 Free setting, electronic thermal frequency 3 b016 Free setting, electronic thermal current 1 b018 Free setting, electronic thermal current 2 b020 Free setting, electronic thermal current 3 Page 4-46 00: Reduced TRQ (Reduced torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting) 00 No  0 to 400 0 No Hz 4-46 0.0 to Rated current 0.0 No A * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-33 3-9 Parameter List Parameter No. Lock Overload limit selection Monitor or data range 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/ constant speed operation) 02: ON-Cnst (Enabled in constant speed operation) 03: ON-A/C(R) (Enabled in acceleration/ constant speed operation (Accelerates during regeneration)) Default setting Changes during operation Unit 01 No  Page 3 b022 Overload limit level 0.20 × Rated current to 2.00 × Rated current 1.50 (0.4 to 55 kW) × 0.20 × Rated current to 1.80 × Rated current Rated (75 to 132 kW) current b023 Overload limit parameter 0.10 to 30.00 b024 Overload limit selection 2 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/ constant speed operation) 02: ON-Cnst (Enabled in constant speed operation) 03: ON-A/C(R) (Enabled in acceleration/ constant speed operation (Accelerates during regeneration)) 1.00 No A No s 4-49 No  b025 0.20 × Rated current to 2.00 × Rated current 1.50 (0.4 to 55 kW) × Overload limit level 2 0.20 × Rated current to 1.80 × Rated current Rated (75 to 132 kW) current No A b026 Overload limit parameter 2 0.10 to 30.00 1.00 No s b027 Overcurrent suppression function 00: OFF (Disabled) 01: ON (Enabled) 00 No  b028 0.20 × Rated current to 2.00 × Rated current Active Frequency (0.4 to 55 kW) Rated Matching restart level 0.20 × Rated current to 1.80 × Rated current current (75 to 132 kW) No A b029 Active Frequency Matching restart parameter 0.10 to 30.00 0.50 No s b030 Starting frequency at Active Frequency Matching restart 00: Off FQ (Frequency at interruption) 01: Max.FQ (Max. frequency) 02: Set FQ (Set frequency) 00 No  Soft lock selection 00: Lock (SFT) (Data other than b031 cannot be changed when terminal SFT is ON) 01: Only FQ (SFT) (Data other than b031 and the specified frequency parameter cannot be changed when terminal SFT is ON) 02: Lock (Data other than b031 cannot be changed) 03: Only FQ (Data other than b031 and the specified frequency parameter cannot be changed) 10: RUN chg mode (Data other than parameters changeable during operation cannot be changed) 01 No  b031 01 4-51 4-43 4-71 4-51 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-34 Operation Overload limit, Overcurrent Protection b021 Function name 3-9 Parameter List Parameter No. Function name Changes during operation Unit Page RUN time/Power ON time setting 0 to 65535 0 No h 4-52 b035 Rotation direction limit selection 00: FREE (Forward and Reverse are enabled) 01: FWD (Only Forward is enabled) 02: REV (Only Reverse is enabled) 00 No  4-52 b036 Reduced voltage startup selection 0 (Reduced voltage startup time: small) to 255 (Reduced voltage startup time: large) 6 No  4-53 b037 Display selection 00: All (Complete display) 01: Utilized (Individual display of functions) 02: User (User setting) 03: Compare (Data comparison display) 04: Basic (Basic display) 00 No  4-53 b038 Initial screen selection 000 to 202 001 No  4-56 b039 User parameter automatic setting function selection 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-57 b040 00: 4-quadrant (Four-quadrant separate setting) 01: TRQ input (Terminal switch) Torque limit selection 02: [O] input (Analog input) 03: Option 1 04: Option 2 00 No - 4-57 4-59 b041 Torque limit 1 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) forward power no (Torque limit disabled) running) 150 No % 4-57 4-59 b042 Torque limit 2 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) reverse regeneration) no (Torque limit disabled) 150 No % b043 Torque limit 3 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) reverse power no (Torque limit disabled) running) 150 No % b044 Torque limit 4 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) forward regeneration) no (Torque limit disabled) 150 No % b045 Torque LADSTOP selection 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-59 b046 Reverse rotation prevention selection 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-59 b049 Dual rate selection 00: CT (Constant torque) 01: VT (Variable torque) 00 No   Others Torque limit Others Default setting b034 3 Operation Monitor or data range 4-57 4-59 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-35 3-9 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 00 No  b050 00: OFF (Disabled) Selection of non-stop 01: V-Cnst (STOP) (Enabled (deceleration function at stop)) momentary power 02: NS1 (Enabled (without recovery)) interruption 03: NS2 (Enabled (with recovery)) b051 Starting voltage of non-stop function at momentary power interruption 0.0 to 1000.0 220/ 440 No V b052 Stop deceleration level of non-stop function at momentary power interruption 0.0 to 1000.0 360/ 720 No V b053 Deceleration time of non-stop function at momentary power interruption 0.01 to 3600.00 1.00 No s b054 Deceleration starting width of non-stop function at momentary power interruption 0.00 to 10.00 0.00 No Hz b055 Proportional gain setting of non-stop function at momentary power interruption 0.00 to 2.55 0.20 Yes  b056 Integral time setting of non-stop function at momentary power interruption 0.000 to 65.535 0.100 Yes s Page 3 4-63 Others * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-36 Operation 4-60 3-9 Parameter List Parameter No. Others Operation 3 Function name Monitor or data range Default setting Changes during operation Unit b060 Window comparator O upper limit level Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 100 Yes % b061 Window comparator O lower limit level Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 0 Yes % b062 Window comparator O hysteresis width Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b063 Window comparator OI upper limit level Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 100 Yes % b064 Window comparator OI lower limit level Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 0 Yes % b065 Window comparator OI hysteresis width Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b066 Window comparator O2 upper limit level Set an upper limit level. Setting range: -100 to 100 Lower limit: Lower limit level + Hysteresis width × 2 100 Yes % b067 Window comparator O2 lower limit level Set a lower limit level. Setting range: -100 to 100 Upper limit: Upper limit level - Hysteresis width × 2 -100 Yes % b068 Window comparator O2 hysteresis width Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b070 Analog operation level at O disconnection 0 to 100/no (ignored) no No  b071 Analog operation level at OI disconnection 0 to 100/no (ignored) no No  b072 Analog operation level at O2 disconnection -100 to 100/no (ignored) no No  Page 4-66 4-66 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-37 3-9 Parameter List Parameter No. Monitor or data range Default setting Changes during operation Unit Cleared with the Enter key after changing to 01 00 Yes  Function name b078 Integrated power clear b079 Integrated power display gain 1 to 1000 b082 Starting frequency Page 4-4 1 No  0.10 to 9.99 0.50 No Hz 0.5 to 15.0 (0.4 to 55 kW) *Derating enabled 5.0 No kHz 0.5 to 10.0 (75 to 132 kW) *Derating enabled 3.0 No kHz 00: no (Clears the trip monitor) 01: Trip data (Initializes data) 02: Parameters (Clears the trip monitor and initializes data) Initialization selection 03: Trip+Param (Clears the trip monitor and parameters) 04: Trp+Prm+EzSQ (Clears the trip monitor, parameters and Drive program) 00 No  b085 Initialization parameter selection 01 No  b086 Frequency 0.1 to 99.9 conversion coefficient 1.0 Yes  4-2 b087 STOP key selection 00: ON (Enabled) 01: OFF (Disabled) 02: Only RESET (Disabled only during stop) 00 No  4-70 b088 Free-run stop selection 00: 0 Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart) 00 No  4-71 b089 Automatic carrier reduction 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-73 b090 Usage rate of regenerative braking function 0.0 to 100.0 0.0 No % 4-74 b091 Stop selection 00: Decel-Stop (Deceleration  Stop) 01: Free-RUN (Free-run stop) 00 No  4-70 b092 Cooling fan control 00: Alws-ON (Always ON) 01: ON in RUN (ON during RUN) 01 No  b095 00: OFF (Disabled) Regenerative braking 01: RUN-ON (Enabled (Disabled during function operation stop)) selection 02: Alws-ON (Enabled (Enabled during stop)) 00 No  b096 Regenerative braking 330 to 380 function ON level 660 to 760 360/ 720 No V b098 Thermistor selection 00 No  b083 Others b099 3 4-68 4-120 Carrier frequency 01 *Do not change. 00: Disabled 01: PTC enabled 02: NTC enabled Thermistor error level 0 to 9999 Operation b084 4-68 4-70 4-74 4-75 3000 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-38 3-9 Parameter List Parameter No. Vf free setting Others Operation 3 Function name Monitor or data range Default setting Changes during operation Unit 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz b100 Free V/f frequency 1 0 to Free V/f frequency 2 b101 Free V/f voltage 1 0.0 to 800.0 b102 Free V/f frequency 2 0 to Free V/f frequency 3 b103 Free V/f voltage 2 0.0 to 800.0 b104 Free V/f frequency 3 0 to Free V/f frequency 4 b105 Free V/f voltage 3 0.0 to 800.0 b106 Free V/f frequency 4 0 to Free V/f frequency 5 b107 Free V/f voltage 4 0.0 to 800.0 b108 Free V/f frequency 5 0 to Free V/f frequency 6 b109 Free V/f voltage 5 0.0 to 800.0 b110 Free V/f frequency 6 0 to Free V/f frequency 7 b111 Free V/f voltage 6 0.0 to 800.0 b112 Free V/f frequency 7 0 to 400 b113 Free V/f voltage 7 0.0 to 800.0 0.0 No V b120 Brake control selection 00: OFF (Disabled) 01: ON (Enabled) 00 No  b121 Brake wait time for release 0.00 to 5.00 0.00 No s b122 Brake wait time for acceleration 0.00 to 5.00 0.00 No s b123 Brake wait time for stopping 0.00 to 5.00 0.00 No s b124 Brake wait time for confirmation 0.00 to 5.00 0.00 No s b125 Brake release frequency 0.00 to -400.00 0.00 No Hz b126 Brake release current 0.0 to 2.00 × Rated current (0.4 to 55 kW) 0.0 to 1.80 × Rated current (75 to 132 kW) Rated current No  b127 Brake input frequency 0.00 to 400.00 0.00 No Hz Page 4-22 4-77 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-39 3-9 Parameter List Function name Monitor or data range Default setting Changes during operation Unit 01 No  Page b130 Overvoltage protection function selection during deceleration 00: OFF (Disabled) 01: V-const (DC voltage kept constant) 02: Accel (Acceleration enabled) b131 Overvoltage protection level during deceleration 200-V class: 330 to 390 400-V class: 660 to 780 380/ 760 No V b132 Overvoltage protection parameter 0.10 to 30.00 1.00 No s b133 Overvoltage protection proportional gain setting 0.00 to 2.55 0.50 Yes  b134 Overvoltage protection integral time setting 0.000 to 65.535 0.060 Yes s b164 Auto return initial display 00: OFF 01: ON 00 No   b166 Data Read/Write selection 00: R/W OK (Read/Write OK) 01: R/W Protected (Read/Write Protected) 00 No   b180 Initialize trigger 00: No action 01: Initialize 00 No   3 4-78 Operation Others Parameter No. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-40 3-9 Parameter List Parameter No. Function name C001 Multi-function input 1 selection *1 C002 Multi-function input 2 selection C003 Multi-function input 3 selection *1 C004 Multi-function input 4 selection Multi-function input terminals Operation 3 C005 Multi-function input 5 selection C006 Multi-function input 6 selection C007 Multi-function input 7 selection C008 Multi-function input 8 selection Monitor or data range 01: RV (reverse) 02: CF1 (multi-step speed setting binary 1) 03: CF2 (multi-step speed setting binary 2) 04: CF3 (multi-step speed setting binary 3) 05: CF4 (multi-step speed setting binary 4) 06: JG (jogging) 07: DB (external DC injection braking) 08: SET (2nd control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (free-run stop) 12: EXT (external trip) 13: USP (USP function) 14: CS (commercial switch) 15: SFT (soft lock) 16: AT (analog input switching) 17: SET3 (3rd control) 18: RS (reset) 20: STA (3-wire start) 21: STP (3-wire stop) 22: F/R (3-wire forward/reverse) 23: PID (PID enabled/disabled) 24: PIDC (PID integral reset) 26: CAS (control gain switching) 27: UP (UP/DWN function accelerated) 28: DWN (UP/DWN function decelerated) 29: UDC (UP/DWN function data clear) 31: OPE (forced operator) 32: SF1 (multi-step speed setting bit 1) 33: SF2 (multi-step speed setting bit 2) 34: SF3 (multi-step speed setting bit 3) 35: SF4 (multi-step speed setting bit 4) 36: SF5 (multi-step speed setting bit 5) 37: SF6 (multi-step speed setting bit 6) 38: SF7 (multi-step speed setting bit 7) 39: OLR (overload limit switching) 40: TL (torque limit enabled) 41: TRQ1 (torque limit switching 1) 42: TRQ2 (torque limit switching 2) 43: PPI (P/PI switching) 44: BOK (Brake confirmation) 45: ORT (orientation) 46: LAC (LAD cancel) 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission) 50: ADD (frequency addition) 51: F-TM (forced terminal block) 52: ATR (torque command input permission) 53: KHC (integrated power clear) 54: SON (servo ON) 55: FOC (preliminary excitation) 56: MI1 (Drive programming input 1) 57: MI2 (Drive programming input 2) 58: MI3 (Drive programming input 3) 59: MI4 (Drive programming input 4) 60: MI5 (Drive programming input 5) 61: MI6 (Drive programming input 6) 62: MI7 (Drive programming input 7) 63: MI8 (Drive programming input 8) 65: AHD (analog command held) 66: CP1 (position command selection 1) 67: CP2 (position command selection 2) 68: CP3 (position command selection 3) 69: ORL (zero return limit signal) 70: ORG (zero return startup signal) 71: FOT (forward driving stop) 72: ROT (reverse driving stop) 73: SPD (speed/position switching) 74: PCNT (pulse counter) 75: PCC (pulse counter clear) 82: PRG (Drive program start) no: NO (no allocation) Default setting Changes during operation Unit Page No  4-79 01 *1 12 18 02 03 06 08 no *1. C001 and C003 are forcibly rewritten into 18 (RS) and 64 (EMR), respectively, when the emergency shutoff function is enabled (SW1 = ON). (64 cannot be set optionally.) When SW1 is turned ON once and then OFF, C003 has no allocations ("no"). * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-41 3-9 Parameter List Function name Monitor or data range Default setting C011 Multi-function input 1 operation selection 00 C012 Multi-function input 2 operation selection 00 C013 Multi-function input 3 operation selection 00 C014 Multi-function input 4 operation selection 00 C015 Multi-function input 5 operation selection C016 Multi-function input 6 operation selection 00 C017 Multi-function input 7 operation selection 00 C018 Multi-function input 8 operation selection 00 C019 FW terminal operation selection 00 00: NO 01: NC 00 Changes during operation Unit Page 3 No  4-81 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-42 Operation Multi-function input terminals Parameter No. 3-9 Parameter List Parameter No. Function name C021 Multi-function output terminal 11 selection C022 Multi-function output terminal 12 selection C023 Multi-function output terminal 13 selection Multi-function output terminal Operation 3 C024 Multi-function output terminal 14 selection C025 Multi-function output terminal 15 selection C026 Relay output (AL2, AL1) function selection Monitor or data range 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) 03: OL (overload warning) 04: OD (excessive PID deviation) 05: AL (alarm output) 06: FA3 (set-frequency-only arrival signal) 07: OTQ (overtorque) 08: IP (signal during momentary power interruption) 09: UV (signal during undervoltage) 10: TRQ (torque limit) 11: RNT (RUN time over) 12: ONT (Power ON time over) 13: THM (thermal warning) 19: BRK (brake release) 20: BER (brake error) 21: ZS (0 Hz signal) 22: DSE (excessive speed deviation) 23: POK (position ready) 24: FA4 (set frequency exceeded 2) 25: FA5 (set frequency only 2) 26: OL2 (overload warning 2) 27: ODc (analog O disconnection detection) 28: OIDc (analog OI disconnection detection) 29: O2Dc (analog O2 disconnection detection) 31: FBV (PID FB status output) 32: NDc (network error) 33: LOG1 (logic operation output 1) 34: LOG2 (logic operation output 2) 35: LOG3 (logic operation output 3) 36: LOG4 (logic operation output 4) 37: LOG5 (logic operation output 5) 38: LOG6 (logic operation output 6) 39: WAC (capacitor life warning signal) 40: WAF (cooling fan life warning signal) 41: FR (starting contact signal) 42: OHF (fin overheat warning) 43: LOC (light load detection signal) 44: MO1 (Drive programming output 1) 45: MO2 (Drive programming output 2) 46: MO3 (Drive programming output 3) 47: MO4 (Drive programming output 4) 48: MO5 (Drive programming output 5) 49: MO6 (Drive programming output 6) 50: IRDY (operation ready signal) 51: FWR (forward run signal) 52: RVR (reverse run signal) 53: MJA (fatal fault signal) 54: WCO (window comparator O) 55: WCOI (window comparator OI) 56: WCO2 (window comparator O2) 63: OPO (Option board output) no: Not used (When C062 is used to select the alarm code output, the multi-function output terminals 11 to 13, or 11 to 14 are forcibly changed to AC0 to AC2 or AC0 to AC3 [Acn 'Alarm code output'], respectively.) Default setting Changes during operation Unit Page No  4-95 00 21 03 07 01 05 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-43 3-9 Parameter List Parameter No. C028 Monitor or data range Default setting Changes during operation Unit FM selection When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 03: Pulse FQ (Digital output frequency) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 12: YA0 (Drive programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2) 00 No  AM selection When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 11: Out TRQ sign (Output torque ) 13: YA1 (Drive programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2) 00 No  00 Page 3 4-109 4-118 Operation Analog monitor C027 Function name 4-110 4-118 C029 AMI selection When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 14: YA2 (Drive programming) C030 Digital current monitor reference value 0.20 × Rated current to 2.00 × Rated current Rated (Current value at the digital current monitor current output 1440 Hz) No  Yes A 4-109 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-44 3-9 Parameter List Function name Monitor or data range Default setting C031 Multi-function output terminal 11 contact selection C032 Multi-function output terminal 12 contact selection C033 Multi-function output terminal 13 contact selection C034 Multi-function output terminal 14 contact selection C035 Multi-function output terminal 15 contact selection C036 Relay output (AL2, AL1) contact selection 00: NO contact at AL2; NC contact at AL1 01: NC contact at AL2; NO contact at AL1 01 Light load signal output mode 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) 01 C038 00: NO 01: NC Changes during operation Unit Page No  4-96 No  00 4-106 Light load detection level 0.0 to 2.00 × Rated current (0.4 to 55 kW) 0.0 to 1.80 × Rated current (75 to 132 kW) Overload warning signal output mode 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) C041 Overload warning level 0.0: Does not operate. 0.1 × Rated current to 2.00 × Rated current (0.4 to 55 kW) 0.1 × Rated current to 1.80 × Rated current (75 to 132 kW) C042 Arrival frequency during acceleration 0.00 to 400.00 C043 Arrival frequency during deceleration 0.00 to 400.00 0.00 No Hz C044 PID deviation excessive level 0.0 to 100.0 3.0 No % C045 Arrival frequency 0.00 to 400.00 during acceleration 2 0.00 No Hz C046 Arrival frequency 0.00 to 400.00 during deceleration 2 0.00 No Hz C052 PID FB upper limit 0.0 to 100.0 100.0 No % C053 PID FB lower limit 0.0 to 100.0 0.0 No % C039 C040 Level and output terminal status Operation 3 Multi-function output terminal Parameter No. Rated current No A 01 No  4-49 Rated current No A 0.00 No Hz 4-98 4-31 4-98 4-31 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-45 3-9 Parameter List Communication function Function name C055 Overtorque level (Forward power running) C056 Overtorque level (Reverse regeneration) Monitor or data range Default setting Changes during operation Unit 200 No % 200 No % 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) C057 Overtorque level (Reverse power running) C058 Overtorque level (Forward regeneration) C061 Thermal warning level C062 00: OFF (Disabled) Alarm code selection 01: 3-bit 02: 4-bit C063 0 Hz detection level C064 Fin overheat warning 0 to 200 level C071 Communication speed selection (Baud rate selection) C072 Page 4-100 200 No % 200 No % 80 No % 4-46 00 No  4-101 0.00 No Hz 4-101 120 No C 4-105 02: Loop-back test 03: 2400 bps 04: 4800 bps 05: 9600 bps 06: 19200 bps 05 No  Communication station No. selection 1 to 247 1 No  C073 Communication bit length selection 7: 7-bit 8: 8-bit 8 No  C074 Communication parity selection 00: No parity 01: Even 02: Odd 00 No  C075 Communication stop bit selection 1: 1-bit 2: 2-bit 1 No  C076 00: Trip 01: Decel-Trip (Trip after deceleration stop) Communication error 02: Ignore selection 03: Free-RUN (Free-run stop) 04: Decel-Stop (Deceleration stop) 02 No  C077 Communication error 0.00 to 99.99 timeout 0.00 No s C078 Communication wait time 0 to 1000 0 No ms C079 Communication method selection 00: ASCII 01: ModBus-RTU 0 to 100 0.00 to 100.00 4-146 4-104 4-146 4-146 01 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-46 3 Operation Level and output terminal status Parameter No. 3-9 Parameter List Adjustment Terminal Meter adjustment Others Operation 3 Adjustment Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page C081 O adjustment 0 to 65535 Factory default Yes   C082 OI adjustment 0 to 65535 Factory default Yes   C083 O2 adjustment 0 to 65535 Factory default Yes   C085 Thermistor adjustment 0.0 to 1000.0 Factory default Yes  4-75 C091 Debug mode selection Use "00". * Do not change. 00 No   C101 UP/DWN selection 00: Not save (Do not store the frequency data) 01: Save (Store the frequency data) 00 No  4-90 C102 Reset selection 00: ON-RESET (Trip reset at power-on) 01: OFF-RESET (Trip reset when the power is OFF) 02: On in Trip (Enabled only during trip (Reset when the power is ON)) 03: Trip RESET (Trip reset only) 00 Yes  4-87 4-137 C103 Reset frequency matching selection 00: 0 Hz start 01: f-match (Frequency matching start) 02: Actv, f-match (Active Frequency Matching restart) 00 No  4-87 C105 FM gain setting 50 to 200 100 Yes % 4-110 C106 AM gain setting 50 to 200 100 Yes % C107 AMI gain setting 50 to 200 100 Yes % C109 AM bias setting 0 to 100 0 Yes % C110 AMI bias setting 0 to 100 20 Yes % C111 Overload warning level 2 0.0 to 2.00 × Rated current (0.4 to 55 kW) 0.0 to 1.80 × Rated current (75 to 132 kW) Rated current No A C121 O zero adjustment 0 to 65535 Factory default Yes  C122 OI zero adjustment 0 to 65535 Factory default Yes  C123 O2 zero adjustment 0 to 65535 Factory default Yes  4-111 4-49  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-47 3-9 Parameter List Output terminal operation function Function name Monitor or data range Default setting C130 Output 11 ON delay 0.0 to 100.0 0.0 C131 Output 11 OFF delay 0.0 to 100.0 0.0 C132 Output 12 ON delay 0.0 to 100.0 0.0 C133 Output 12 OFF delay 0.0 to 100.0 0.0 C134 Output 13 ON delay 0.0 to 100.0 0.0 C135 Output 13 OFF delay 0.0 to 100.0 0.0 C136 Output 14 ON delay 0.0 to 100.0 0.0 C137 Output 14 OFF delay 0.0 to 100.0 0.0 C138 Output 15 ON delay 0.0 to 100.0 0.0 C139 Output 15 OFF delay 0.0 to 100.0 0.0 C140 Relay output ON delay 0.0 to 100.0 0.0 C141 Relay output OFF delay 0.0 to 100.0 0.0 C142 Logic output signal 1 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C143 Logic output signal 1 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C144 Logic output signal 1 operator selection 00: AND 01: OR 02: XOR 00 C145 Logic output signal 2 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C146 Logic output signal 2 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C147 Logic output signal 2 operator selection 00: AND 01: OR 02: XOR 00 C148 Logic output signal 3 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C149 Logic output signal 3 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C150 Logic output signal 3 operator selection 00: AND 01: OR 02: XOR 00 C151 Logic output signal 4 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 Changes during operation Unit Page 3 No s 4-108 No  4-102 Operation Output terminal operation function Parameter No. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-48 3-9 Parameter List Input terminal response Others Operation 3 Output terminal operation function Parameter No. Function name Monitor or data range Default setting C152 Logic output signal 4 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C153 Logic output signal 4 operator selection 00: AND 01: OR 02: XOR 00 C154 Logic output signal 5 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C155 Logic output signal 5 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C156 Logic output signal 5 operator selection 00: AND 01: OR 02: XOR 00 C157 Logic output signal 6 selection 1 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C158 Logic output signal 6 selection 2 Same as options for C021 to C026 (excluding LOG1 to LOG6) 00 C159 Logic output signal 6 operator selection 00: AND 01: OR 02: XOR 00 C160 Input terminal response time 1 0 to 200 (× 2 ms) 1 C161 Input terminal response time 2 0 to 200 (× 2 ms) 1 C162 Input terminal response time 3 0 to 200 (× 2 ms) 1 C163 Input terminal response time 4 0 to 200 (× 2 ms) 1 C164 Input terminal response time 5 0 to 200 (× 2 ms) 1 C165 Input terminal response time 6 0 to 200 (× 2 ms) 1 C166 Input terminal response time 7 0 to 200 (× 2 ms) 1 C167 Input terminal response time 8 0 to 200 (× 2 ms) 1 C168 FW terminal response 0 to 200 (× 2 ms) time 1 C169 Multi-step speed/ position determination time 0 0 to 200 (× 2 ms) Changes during operation Unit Page No  4-102 No ms 4-108 No ms 4-16 4-137 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-49 3-9 Parameter List Parameter No. Function name Monitor or data range Changes during operation Unit Page No  4-111 No  4-111 4-113 4-115 No kW H001 00: OFF (Disabled) Auto-tuning selection 01: ON (STOP) 02: ON (Rotation) 00 H002 Motor parameter selection 00 H202 * 2nd motor parameter selection H003 Motor capacity selection H203 * 2nd motor capacity selection H004 Motor pole number selection H204 * 2nd motor pole number selection H005 Speed response 00: Standard motor parameter 01: Auto-tuning parameter 02: Auto-tuning parameter (online auto-tuning enabled) 00 Factory default 0.20 to 160.0 Factory default 4 2/4/6/8/10 Control parameter * 2nd speed response H006 Stabilization parameter H206 * 2nd stabilization parameter H306 * 3rd stabilization parameter H020 H021 H022 0 to 255 4-89 4-92 100 Yes  4-120 No  No  No mH 100 Depends on the motor capacity. Motor parameter R1 * 2nd motor parameter R1 Depends on the motor capacity. Motor parameter R2 Depends on the motor capacity. * 2nd motor parameter R2 Depends on the motor capacity. Motor parameter L Depends on the motor capacity. * 2nd motor parameter L  100 0.01 to 655.35 H222 Yes 1.590 0.001 to 65.535 H221 Pole 1.590 0.001 to 65.535 H220 No 4 0.001 to 80.000 H205 4-19 4-111 4-115 4-118 4-115 Depends on the motor capacity. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-50 3 Operation Default setting 3-9 Parameter List Parameter No. H023 Function name Monitor or data range Default setting H223 Unit No A Page Depends on the motor capacity. Motor parameter IO 0.01 to 655.35 3 Changes during operation * 2nd motor parameter IO Depends on the motor capacity. Motor parameter J Depends on the motor capacity. Operation 4-115 H024 0.001 to 9999.000 H224 * 2nd motor parameter J Depends on the motor capacity. H030 Motor parameter R1 (auto-tuning data) Depends on the motor capacity. H230 * 2nd motor parameter R1 (auto-tuning data) Depends on the motor capacity. H031 Motor parameter R2 (auto-tuning data) Depends on the motor capacity. H231 * 2nd motor parameter R2 (auto-tuning data) Depends on the motor capacity. H032 Motor parameter L (auto-tuning data) Depends on the motor capacity. H232 * 2nd motor parameter L (auto-tuning data) Depends on the motor capacity. H033 Motor parameter IO (auto-tuning data) Depends on the motor capacity. H233 * 2nd motor parameter IO (auto-tuning data) Control parameter 0.001 to 65.535 0.001 to 65.535 0.01 to 655.35 0.01 to 655.35 No kgm2 No  No  4-111 4-115 No mH No A Depends on the motor capacity. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-51 3-9 Parameter List Parameter No. Function name H034 Motor parameter J (auto-tuning data) Monitor or data range Default setting Unit Page No kgm2 4-111 4-115 Depends on the motor capacity. 0.001 to 9999.000 Depends on the motor capacity. H050 PI proportional gain 100.0 H250 * 2nd PI proportional gain H051 PI integral gain 0.0 to 1000.0 3 Yes  Yes  Yes  Yes % 100.0 100.0 H251 *2nd PI integral gain 100.0 H052 P proportional gain 1.00 H252 *2nd P proportional gain H060 Limit at 0 Hz 0.01 to 10.00 4-89 4-92 1.00 100.0 0.0 to 100.0 H260 * 2nd limit at 0 Hz 100.0 H061 Boost amount at SLV startup, 0 Hz H261 * 2nd boost amount at SLV startup, 0 Hz H070 For PI proportional gain switching 0.0 to 1000.0 H071 For PI integral gain switching 0.0 to 1000.0 H072 For P proportional gain switching 0.00 to 10.00 1.00 Yes  H073 Gain switching time 0 to 9999 100 Yes ms 4-117 50 0 to 50 Yes % 100.0 Yes  100.0 Yes  50 4-89 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-52 Operation H234 * 2nd motor parameter J (auto-tuning data) 0.0 to 1000.0 Control parameter Changes during operation 3-9 Parameter List Parameter No. Function name Monitor or data range P001 Operation selection at option 1 error 00: Trip 01: RUN (Continues operation) P002 Operation selection at option 2 error 00: Trip 01: RUN (Continues operation) P011 Encoder pulses 128 to 65535 P012 Default setting Changes during operation Unit 00 No  Page 4-111 Options Operation 3 00 No  1024 No Pulse 4-124 4-133 4-134 V2 control mode selection 00: ASR (speed control mode) 01: APR (pulse train position control mode) 02: APR2 (absolute position control mode) 03: HAPR (High resolution absolute position control mode) 00 No  4-124 4-136 P013 Pulse train mode selection 00: Mode 1 01: Mode 2 02: Mode 3 00 No  4-127 P014 Orientation stop position 0 to 4095 0 No  P015 Orientation speed setting Starting frequency to Max. frequency (upper limit: 120.0) 5.00 No Hz P016 Orientation direction setting 00: FWD (Forward side) 01: REV (Reverse side) 00 No  P017 Position ready range setting 0 to 10000 5 No Pulse 4-127 4-134 P018 Position ready delay time setting 0.00 to 9.99 0.00 No s 4-127 4-134 P019 Electronic gear setting position selection 00: FB (Position feedback side) 01: REF (Position command side) 00 Yes  P020 Electronic gear ratio numerator 1 to 9999 1 Yes  P021 Electronic gear ratio denominator 1 to 9999 1 Yes  P022 Position control feedforward gain 0.00 to 655.35 0.00 Yes  4-134 4-128 4-129 0.50 Yes rad/s 4-124 4-128 4-129 4-134 4-136 Position bias amount -2048 to 2048 0 Yes rad/s 4-128 P025 Secondary resistance compensation 00: OFF (Disabled) enable/disable 01: ON (Enabled) selection 00 No  4-114 P026 Overspeed error detection level 135.0 No % 5-7 P027 Speed deviation error 0.00 to 120.00 detection level 7.50 No Hz 4-124 P023 Position loop gain P024 0.00 to 100.00 0.0 to 150.0 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-53 3-9 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 1 No  Page P028 Motor gear ratio numerator P029 Motor gear ratio denominator 1 to 9999 1 No  P031 Acceleration/ deceleration time input type 00: OPE (Digital Operator) 01: Option 1 02: Option 2 03: EzSQ (Drive Programming) 00 No  4-8 P032 Orientation stop position input type 00: OPE (Digital Operator) 01: Option 1 02: Option 2 00 No   P033 Torque reference input selection 00: O (Terminal O) 01: OI (Terminal OI) 02: O2 (Terminal O2) 03: OPE (Digital Operator) 06: Option 1 07: Option 2 00 No  P034 Torque reference setting 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 0 Yes % P035 Polarity selection at torque reference via O2 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00 No  Torque bias mode 00: OFF (None) 01: OPE (Digital Operator) 02: O2 (Terminal O2) 05: Option 1 06: Option 2 00 No  1 to 9999 P036 4-126 4-126 4-127 P037 Torque bias value -200 to +200 (0.4 to 55 kW) -180 to +180 (75 to 132 kW) 0 Yes % P038 Torque bias polarity selection 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00 No  P039 Speed limit value in torque control (forward) 0.00 to Maximum frequency 0.00 Yes Hz P040 Speed limit value in torque control (reverse) 0.00 to Maximum frequency 0.00 Yes Hz P044 DeviceNet comm Watch dog timer 0.00 to 99.99 1.00 No s  P045 00: Trip 01: Decel-Trip (Trip after deceleration stop) Operation setting at 02: Ignore communications error 03: Free RUN 04: Decel-Stop (Deceleration stop) 00 No   4-126 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-54 3 Operation Options 4-133 3-9 Parameter List Monitor or data range Default setting Changes during operation Unit Page Instance Number 0: Basic speed I/O 1: Extended speed I/O 2: Extended speed and Torque control 3: Special I/O 4: Extended control I/O 5: Extended control I/O and multifunction I/O monitor 6: Flexible format 7: Extended speed and Acceleration control 8-20: Not used 1 No   P048 Operation setting at idle mode detection 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) 00 No   P049 Polarity setting for rotation speed 0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/ 32/34/36/38 0 No   P055 Pulse train frequency 1.0 to 50.0 scale 25.0 No kHz P056 Pulse train frequency 0.01 to 2.00 filter time constant 0.10 No s P057 Pulse train frequency -100 to 100 bias amount P058 Pulse train frequency 0 to 100 limit Parameter No. P046 Function name Options Operation 3 4-144 0 No % 100 No % * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-55 3-9 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation P060 Multi-step position command 0 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P061 Multi-step position command 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P062 Multi-step position command 2 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P063 Multi-step position command 3 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 Multi-step position command 4 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P065 Multi-step position command 5 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P066 Multi-step position command 6 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P067 Multi-step position command 7 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P068 Zero return mode 00: Low speed 01: High speed 1 02: High speed 2 00 Yes  P069 Zero return direction selection 00: FWD (Forward side) 01: REV (Reverse side) 00 Yes  P070 Low-speed zero return frequency 0.00 to 10.00 0.00 Yes Hz P071 High-speed zero return frequency 0.00 to Maximum frequency 0.00 Yes Hz P072 Position range specification (forward) 0 to 268435455 (at P012 = 02) 0 to 1073741823 (at P012 = 03) 268435455 Yes  Operation P064 Page 3 Yes Absolute position control Unit  4-136 4-136 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-56 3-9 Parameter List Monitor or data range Default setting Changes during operation Unit Position range specification (reverse) -268435455 to 0 (at P012 = 02) -1073741823 to 0 (at P012 = 03) -268435455 Yes  Teaching selection 00: X00 (Multi-step position command 0 (P060)) 01: X01 (Multi-step position command 1 (P061)) 02: X02 (Multi-step position command 2 (P062)) 03: X03 (Multi-step position command 3 (P063)) 04: X04 (Multi-step position command 4 (P064)) 05: X05 (Multi-step position command 5 (P065)) 06: X06 (Multi-step position command 6 (P066)) 07: X07 (Multi-step position command 7 (P067)) 00 Yes  Drive Program parameter U(00) to U(31) 0 to 65535 0 Yes   P160 to P169 Option I/F cmd W register 1 to 10 0000 to FFFF 0000 Yes   P170 to P179 Option I/F cmd R register 1 to 10 0000 to FFFF 0000 Yes   P180 Profibus node address 0 to 125 0 No   P181 Profibus clear mode 00: Clear 01: Last value 00 No   P182 Profibus Map selection 00: PPO 01: Conventional 02: Flexible mode 00 No   P185 CANOpen Node address 0 to 127 0 No   P186 CANOpen communication speed 00: Auto 01: 10Kbps 02: 20Kbps 03: 50Kbps 04: 125Kbps 05: 250Kbps 06: 500Kbps 07: 800Kbps 08: 1Mbps 06 No   P190 CompoNet node address 0 to 63 0 No   P192 DeviceNet node address 0 to 63 63 No   P195 ML2 frame length 00: 32 bytes 01: 17 bytes 00 No   P196 ML2 node address 21 to 3E 21 No   Parameter No. Operation 3 Absolute position control P073 P074 P100 to P131 Function name Page 4-137 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-57 3-9 Parameter List Function name Monitor or data range Default setting U001 User 1 selection no/d001 to P196 no U002 User 2 selection no/d001 to P196 no U003 User 3 selection no/d001 to P196 no U004 User 4 selection no/d001 to P196 no U005 User 5 selection no/d001 to P196 no U006 User 6 selection no/d001 to P196 no U007 User 7 selection no/d001 to P196 no U008 User 8 selection no/d001 to P196 no U009 User 9 selection no/d001 to P196 no U010 User 10 selection no/d001 to P196 no U011 User 11 selection no/d001 to P196 no U012 User 12 selection no/d001 to P196 no Changes during operation Unit Page 3 Yes  4-53 Operation User parameter Parameter No. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-58 Chapter 4 Functions 4-1 Monitor Mode.................................................... 4-1 4-2 Function Mode.................................................. 4-8 4-3 Functions When PG Option Board (3G3AXPG01) Is Used ................................................... 4-123 4-4 Communication Function................................ 4-145 4-1 Monitor Mode 4Functions 4-1 Monitor Mode Output Frequency Monitor [d001] Displays the set point of output frequency of the Inverter afected by acceleration and deceleration ramps but without compensations. During stop, "0.00" is displayed. (Display) 0.00 to 400.00 Functions 4 : Displays in increments of 0.01 Hz. Note: When the frequency reference is set using the Digital Operator, the output frequency can be changed with the Increment/Decrement key during operation only. The frequency setting changed with this monitor will be reflected in frequency reference F001. Pressing the Enter key overwrites the currently selected frequency reference. Note: This will correspond with the theoretical motor speed but not with the real output frequency of the inverter. Output Current Monitor [d002] Displays the output current value of the Inverter. During stop, "0.00" is displayed. (Display) 0.0 to 9999.0: Displays in increments of 0.1 A. Rotation Direction Monitor [d003] Displays the RUN direction of the Inverter. The RUN LED indicator lights up during forward/reverse rotation. (Display) FWD: Forward STOP: Stop REV: Reverse PID Feedback Value Monitor [d004] When "Enabled" (01) or "Reverse output enabled" (02) is selected in PID selection A071, the PID feedback value can be monitored. Gain conversion is enabled with PID scale A075. "d004 display" = "PID feedback value (%)" × "PID scale (A075)" (A075): 0.01 to 99.99 (Can be set in increments of 0.01.) (Display) 0.00 to 999000.00: Displays in increments of 0.01. 4-1 4-1 Monitor Mode Multi-function Input Monitor [d005] •This monitor indicates the input status of the multi-function input terminals. •The item that the built-in CPU recognizes to be "significant" is indicated as being ON. This does not depend on the NO/NC contact setting. (Example) FW, Multi-function input terminals 7, 2, 1: ON Multi-function input terminals 8, 6, 5, 4, 3: OFF MONITOR-A M1-STOP ALL d005 Input 4 HLHLLLLHH H001 6 5 4 3 2 1 Functions FW 8 7 00:OFF Multi-function Output Monitor [d006] •This monitor indicates the output status of the multi-function output terminals. •This monitor displays the output status of the built-in CPU, not the control circuit terminal status. (Example) Multi-function output terminals 12, 11: ON Relay output terminal AL2, Multi-function output terminals 15, 14, 13: OFF MONITOR-A M1-STOP ALL d006 Output LLLLH H AL2 15 14 13 12 11 H001 00:OFF Output Frequency Monitor (After Conversion) [d007] Displays a gain conversion value based on the coefficient set in frequency conversion coefficient b086. This monitor is used to change the unit of displayed data (e.g. motor rpm). "d007 display" = "Output frequency (d001)" × "Frequency conversion coefficient (b086)" (b086) 0.1 to 99.9 (Can be set in increments of 0.1.) (Example) To display 4-pole motor rpm: Motor rpm N (min-1) = (120 × f (Hz)) / P (pole) = f (Hz) × 30 As such, when b086 = 30.0, a motor rpm of 1800 (60 × 30.0) is displayed. (Display) 0.00 to 39960.00: Displays in increments of 0.01. 4-2 4-1 Monitor Mode Note: When the frequency reference is set using the Digital Operator, the output frequency can be changed with the Increment/Decrement key during operation only. The frequency setting changed with this monitor will be reflected in frequency reference F001. Pressing the Enter key overwrites the currently selected frequency reference. (The data storage accuracy depends on each frequency reference.) Real Frequency Monitor [d008] When a motor with an encoder is connected to a load, and the PG board (3G3AX-PG01) is used, this monitor displays the real frequency of the motor (regardless of the control method). (Display) In forward rotation: 0.00 to 400.00 : Displays in increments of 0.01 Hz. In reverse rotation: 0.00 to -400.00 : Displays in increments of 0.01 Hz. Functions 4 Note 1: To use this monitor, set the number of encoder pulses (P011) and the motor pole number selection (H004 or H204) correctly. Note 2: The monitored value does not depend on V/f characteristics selection A044. Torque Reference Monitor [d009] When torque control is selected for sensor vector control, this monitor displays the currently entered torque reference value. (Display) -200 to 200: Displays in increments of 1%. Torque Bias Monitor [d010] When sensor vector control is selected, this monitor displays the torque bias amount currently set in display code d010. (Display) -200 to 200: Displays in increments of 1%. Output Torque Monitor [d012] Displays an estimated value of the Inverter's output torque. (Display) -200 to 200: Displays in increments of 1%. Note: This monitor is enabled only when "sensorless vector control", "0-Hz sensorless vector control" , or "sensor vector control" is selected as the control mode. Output Voltage Monitor [d013] Displays the output voltage of the Inverter. (Display) 0.0 to 600.0: Displays in increments of 0.1 V. 4-3 4-1 Monitor Mode Input Power Monitor [d014] Displays the input power (instantaneous value) of the Inverter. (Display) 0.0 to 999.9: Displays in increments of 0.1 W. Power ON Time Monitor [d015] •Displays the integrated power (integrated value of input power) of the Inverter. The gain conversion of displayed data is performed with integrated power display gain b079. 4 "d015 display" = "Input power calculation value (kWh)" / "Integrated power display gain (b079)" (b079) 1. to 1000. (Can be set in increments of 1.) (Display) 0 to 999999.9 : Displays in increments of 1 kWh/(b079) set value. Total RUN Time [d016] Displays the total RUN time of the Inverter. (Display) 0 to 999999 : Displays in increments of 1 hour. Power ON Time Monitor [d017] Displays the total power ON time of the Inverter. (Display) 0 to 999999 : Displays in increments of 1 hour. Fin Temperature Monitor [d018] Displays the temperature of the fin inside the Inverter. (Display) -020. to 200.0: Displays in increments of 0.1C. 4-4 Functions •When integrated power clear b078 is set to "01", pressing the Enter key clears the integrated power value. •The integrated power value can also be cleared via terminal input, if "53" (KHC: Integrated power clear) is allocated to any of the multi-function input terminals. •When b079 is set to "1000", up to "999000" (kWh) can be displayed. 4-1 Monitor Mode Motor Temperature Monitor [d019] •Displays the temperature of the thermistor connected between the control circuit terminals TH and CM1. •Set thermistor selection b098 to "02" (NTC enabled). (Display) -020. to 200.0: Displays in increments of 0.1C. Note: When b098 = "01" (PTC enabled), the motor temperature monitor is disabled. Life Assessment Monitor [d022] •This monitor indicates a life assessment result. The following two items can be monitored: 1: Main circuit board capacitor service life 2: Cooling fan rpm reduction Functions 4 MONITOR-A M1-STOP ALL d022 Life(C/F) LL 2 1 H001 00:OFF Note 1: The capacitor service life is calculated every 10 minutes. If the Inverter is turned on/off frequently within this interval, the capacitor service life cannot be correctly diagnosed. Note 2: While the cooling fan is stopped with b092 set to "01", the cooling fan rpm is judged as being normal. Program Counter [d023] Refer to Drive Programming Manual. Display: 0 to 1024 Program Number [d024] Refer to Drive Programming Manual. Display: 0 to 9999 Drive Programming Monitor (UM0 to UM2) [d025 to d027] Refer to Drive Programming Manual. Display: -2147483647 to 2147483647 4-5 4-1 Monitor Mode Pulse Counter Monitor [d028] You can monitor a total pulse count of multi-function input function pulse counter 74 (PCNT). Display: 0 to 2147483647 Position Command Monitor (Absolute Position Control Mode) [d029] You can monitor a position command in absolute position control mode. Note: This monitor is enabled only when V2 control mode selection P012 is set to "02" or "03" in sensor vector control mode. 4 Display: -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected Functions Current Position Monitor (Absolute Position Control Mode) [d030] You can monitor the current position in absolute position control mode. Note: This monitor is enabled only when V2 control mode selection P012 is set to "02" or "03" in sensor vector control mode. Display: -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected Clock [d031] Setting Date and Time for the LCD digital operator. (Display) 2000/1/1 to 2099/12/31: Displays in increments of 1 day. 00:00 to 23:59 : Displays in increments of 1 minute. Inverter Mode [d060] Dual ratting. Refer to b049 parameter. (Display) 00 01 : Constant torque. : Variable torque. Fault Frequency Monitor [d080] Displays the number of times the Inverter has tripped. (Display) 0 to 65535 : Displays in increments of 1 time. 4-6 4-1 Monitor Mode Fault Monitors 1 to 6 [d081] to [d086] Refer to 7. Trip Mode in Chapter 3.4 Operation. Warning Monitor [d090] •If the set data is inconsistent with other data, a warning code is displayed. •While this warning remains in effect, the Warning LED indicator stays lit until forced to rewrite or correct the data. •For details on the Warning display, refer to "5-2 Warning Function". 4 Display: 0 to 385 Functions DC Voltage Monitor [d102] •Displays the DC voltage (between P and N) of the Inverter. •During operation, the monitor value changes depending on the actual DC voltage of the Inverter. (Display) 0.0 to 999.9: Displays in increments of 0.1 V. Regenerative Braking Load Rate Monitor [d103] Displays a regenerative braking load rate. When the monitor value comes close to exceeding the value set in usage rate of the regenerative braking function b090, "E06 (Braking resistor overload protection)" works to trip the Inverter. (Display) 0.0 to 100.0: Displays in increments of 0.1%. Electronic Thermal Monitor [d104] Displays an electronic thermal load rate. When the monitor value comes close to exceeding 100%, "E05 (Overload protection)" works to trip the Inverter. (Display) 0.0 to 100.0: Displays in increments of 0.1%. 4-7 4-2 Function Mode 4-2 Function Mode Output Frequency Setting/Monitor Parameter No. Function name F001 Output frequency setting/monitor A020 Multi-step speed reference 0 A220 *2nd multi-step speed reference 0 A320 *3rd multi-step speed reference 0 Data Default setting Unit 0.00 0.0/Starting frequency to 1st/2nd/3rd max. frequency Hz 6.00 Related functions A001, A020, A220, A320, C001 to C008 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. Acceleration/Deceleration Time •Set an acceleration/deceleration time for the motor. For a slow transition, set to a large value, and for a fast transition, set to a small one. Parameter No. Function name F002 Acceleration time 1 F202 *2nd acceleration time 1 F302 *3rd acceleration time 1 F003 Deceleration time 1 F203 *2nd deceleration time 1 F303 *3rd deceleration time 1 P031 Acceleration/deceleration time input type Data 0.01 to 3600.00 Related functions 00: OPE (Digital Operator) 01: Option 1 02: Option 2 03: EzSQ (Drive Programming) Default setting Unit 10.00 s 00  A004, A204, A304, P031, C001 to C008 * To switch to 2nd/3rd acceleration time 1 or 2nd/3rd deceleration time 1, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. 4-8 4 Functions •Set the Inverter output frequency. •With frequency reference selection A001 set to 02, you can set the output frequency with F001. For other methods, refer to the [A001] section in "Frequency Reference Selection" (page 4-10). (If A001 is set other than to "02", F001 functions as the frequency reference monitor.) •If a frequency is set in F001, the same value is automatically set in multi-step speed reference 0 (A020). To set the 2nd/3rd control, use the 2nd multi-step speed reference 0 (A220)/3rd multi-step speed reference 0 (A320) or use F001 with the SET/SET3 terminal turned on. To set using the SET/SET3 terminal, allocate 08 (SET)/17 (SET3) to the desired multi-function input. •When this monitor is used to display a target value of the PID function, the monitor value is displayed as a percentage (%). (100% = Max. frequency) 4-2 Function Mode •The set time here indicates the acceleration/deceleration time from 0 Hz to the maximum frequency. Output frequency Max. frequency A004/A204/A304 4 Output frequency set value Actual deceleration time Actual acceleration time Functions F002/F202/F302 F003/F203/F303 •When the LAD cancel (LAC) function is selected in the multi-function input selection and the signal is turned on, the acceleration/deceleration time is ignored, and the output frequency instantaneously follows the reference frequency. •To switch between the 1st/2nd/3rd acceleration times or between the 1st/2nd/3rd deceleration times, allocate 08 (SET)/17 (SET3) to the desired multi-function input (refer to "Multi-function Input Selection" (page 4-79)), and use the SET/SET3. •You can set the acceleration/deceleration time via (1) the Digital Operator, (2) optional board 1, or (3) optional board 2. •Even if a short acceleration/deceleration time is set, the actual time cannot be shorter than the minimum acceleration/deceleration time that is determined by the mechanical inertia moment and the motor torque. If you set a time shorter than the minimum time, an overcurrent/overvoltage trip may occur. Acceleration Time TS TS = ( JL + JM ) NM 9.55 (TS TL ) Deceleration Time TB TB = JL: Inertia moment of the load converted to the motor shaft [kg·m2] JM: Inertia moment of the motor [kg·m2] NM: Motor rotation speed [r/min] TS: Max. acceleration torque with the Inverter driving [N·m] TB: Max. deceleration torque with the Inverter driving [N·m] TL: Required driving torque [N·m] ( JL + JM ) NM 9.55 (TB + TL ) For short-time deceleration, use a braking unit (optional). Operator Rotation Direction Selection •Select the rotation direction applied to the RUN command via the Digital Operator. •This is disabled at terminals. Parameter No. Function name F004 Operator rotation direction selection 4-9 Data 00: FWD (Forward) 01: REV (Reverse) Default setting Unit 00  4-2 Function Mode Frequency Reference Selection Select the method for using the frequency reference. Parameter No. Function name Frequency reference selection A001 Data 00: VR (Digital Operator (FREQ adjuster)) 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 06: Pulse train frequency 07: EzSQ (Drive Programming) 10: (Math) Operation function result Default setting Unit 01  4 Functions Related functions Data A005, A141 to A143, A145, A146 Frequency reference source 00 Set a frequency with the FREQ adjuster on the Digital Operator. (Enabled when 3G3AX-OP01 is used.) 01 Set a frequency via terminals. (O-L, OI-L, O2-L) 02 Set a frequency via the Digital Operator (F001). 03 Set a frequency through the ModBus communication. 04 Set a frequency via the PCB mounted to option port 1. 05 Set a frequency via the PCB mounted to option port 2. 06 Set a frequency as a pulse train by using 3G3AX-PG01. 07 Drive Programming 10 The operation result of the frequency operation function is defined as a frequency reference. 4-10 4-2 Function Mode RUN Command Selection Select the method for using the RUN/STOP command. Parameter No. Function name RUN command selection A002 Data Functions Unit 01  01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 Related functions 4 Default setting F004, C001 to C008, C019 Data RUN command source 01 Turn on/off the FW or RV allocated to terminals. The STOP command is activated if both Forward/Reverse commands are input simultaneously. 02 Use the STOP/RESET key on the Digital Operator. 03 Use the ModBus communication. 04 Use option board 1. 05 Use option board 2. Base Frequency •Match the Inverter output (frequency/voltage) to the motor rating. Be careful, especially if you set a base frequency below 50 Hz. Otherwise, the motor may burn out. Parameter No. Function name Data A003 Base frequency A203 *2nd base frequency 30 to 2nd max. frequency [A204] A303 *3rd base frequency 30 to 3rd max. frequency [A304] Default setting Unit 50 Hz 30 to Max. frequency [A004] Related functions A004, A204, A304, A081, A082 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. •For the base frequency and motor voltage selections, match the Inverter output (frequency/ voltage) to the motor rating. Output voltage AVR voltage selection (A082) Base frequency (A003/A203/A303) Output frequency (Hz) •If you apply a base frequency of over 60 Hz, a special motor is required. This may require the Inverter to increase its capacity to accommodate a different applicable motor. •Set the motor voltage selection according to the motor specifications. If the voltage exceeds the specified level, the motor may burn out. 4-11 4-2 Function Mode Maximum Frequency •Set the maximum value of the output frequency. •The value set here is the maximum value (e.g.,10 V in the range from 0 to 10 V) of the external analog input (frequency reference). •The maximum Inverter output voltage from base to maximum frequencies is the voltage set in AVR voltage selection A082. •The Inverter cannot output voltage beyond that of the incoming voltage. Output voltage 4 AVR voltage selection (A082) Parameter No. Function name A004 Maximum frequency A204 *2nd maximum frequency A304 *3rd maximum frequency Max. frequency Data Default setting Unit 50 Hz 30 to 400 Related functions A003, A203, A303, A081, A082 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. Analog Input (O, O2, OI) •The Inverter has three types of external analog input terminals. O-L terminal: 0 to 10 V (voltage input) OI-L terminal: 4 to 20 mA (current input) O2-L terminal: -10 to 10 V (voltage input) •Below are the settings for this function. Parameter No. A005 A006 Function name Data Default setting Unit O/OI selection 00: [O]/[O2] Switches between O/OI terminal AT 01: [O]/[O2] Switches between O/O2 terminal AT 02: [O]/VR Switches between O/FREQ adjuster via terminal AT (Enabled only when 3G3AXOP01 is used.) 03: [OI]/VR Switches between OI/FREQ adjuster via terminal AT (Enabled only when 3G3AXOP01 is used.) 04: [O2]/VR Switches between O2/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used.) 00  00: [O2] only 01: [O/OI-P] Auxiliary frequency reference (not reversible) 02: [O/OI-PM] Auxiliary frequency reference (reversible) 03: [OFF] O2 disabled 03  O2 selection Related functions A005, A006, C001 to C008 4-12 Functions Base frequency 4-2 Function Mode •The frequency reference and reversibility depend on whether "16" (AT) is allocated to a multifunction input, and depend on the combination of A005 and A006, as shown below. If the frequency reference is "reversible", the motor runs in the reverse direction when "main frequency reference + auxiliary frequency reference" is less than zero, even if the FW (Forward) terminal is ON. Also, note that the motor may run in the reverse direction, resulting in prolonged acceleration time or other phenomena, if the voltage fluctuates around 0 V even with the O2 terminal not connected. A006 AT terminal A005 Main frequency reference Auxiliary frequency reference (O2-L terminal) OFF O-L terminal Disabled ON OI-L terminal Disabled OFF O-L terminal Disabled ON O2-L terminal Disabled OFF O-L terminal Enabled ON OI-L terminal Enabled OFF O-L terminal Enabled ON O2-L terminal Disabled OFF O-L terminal Enabled ON OI-L terminal Enabled OFF O-L terminal Enabled ON O2-L terminal Disabled 00 4 Reversibility Not reversible 00, 03 Functions 01 With AT allocated to a multi-function input 00 (Example 1) Reversible Not reversible 01 01 00 (Example 2) Reversible 02 Reversible 01 With AT NOT allocated to a multi-function input 00   O2-L terminal Disabled Reversible 01   Addition of the O-L and OI-L terminals Enabled Not reversible 02   Addition of the O-L and OI-L terminals Enabled Reversible 03   Addition of the O-L and OI-L terminals Disabled Not reversible (Example 1) Not reversible (Example 2) Reversible FW FW AT Main frequency reference OI or O terminal O Auxiliary frequency reference O2terminal fOI AT Main frequency reference OI or O terminal O fO fO2 O fO + fO2 Real frequency reference fOI + fO2 Forward fOI fO2 Auxiliary frequency O reference O2 terminal fO2 + fOI fO2 + fOI Real frequency reference Forward Reverse 4-13 fO 4-2 Function Mode External Frequency (Voltage/Current) Adjustment •External analog input (frequency reference) O-L terminal: 0 to 10 V (voltage input) OI-L terminal: 4 to 20 mA (current input) O2-L terminal: -10 to 10 V (voltage input) Also set an output frequency for the FREQ adjuster on the Digital Operator. Adjusting the O2-L and OI-L Terminals Parameter No. Function name A011 A101 O/OI start frequency Default setting Data 4 0.00 to 400.0 (Set a start/end frequency.) O/OI end frequency A013 A103 O/OI start ratio A014 A104 O/OI end ratio A015 A105 O/OI start selection 0.00 0 to 100 (Set a start/end ratio relative to an external frequency reference of 0 to 10 V and 4 to 20 mA.) 00: External start frequency (A011 set value) 01: 0 Hz Related functions Hz 0 20 % 100 01  00 A003, A203, A303, A081, A082 •To input voltage ranging from 0 to 5 V on the OI-L terminal, set A014 to 50%. (Example 1) A015/A105: 00 (Example 2) A015/A105: 01 Max. frequency Max. frequency A012/A102 A012/A102 A011/A101 A011/A101 0 A013/A103 (0 V/0 mA) A014/A104 100% Analog input (10 V/20 mA) (0/OI) 0 A013/A103 (0 V/0 mA) A014/A104 100% Analog input (10 V/20 mA) (0/OI) 4-14 Functions A012 A102 Unit 4-2 Function Mode Adjusting the O2-L Terminal Default setting Parameter No. Function name Data A111 O2 start frequency -400.00 to 400.00 (Set a start frequency.) 0.00 A112 O2 end frequency -400.00 to 400.00 (Set an end frequency.) 0.00 A113 O2 start ratio -100 to O2 end ratio: (Set a start ratio relative to an external frequency reference of -10 to 10 V. *) -100 O2 end ratio O2 start ratio to 100: (Set an end ratio relative to an external frequency reference of -10 to 10 V. *) Unit Hz % 4 A114 Functions Related functions 100 A003, A203, A303, A081, A082 * Below is the ratio from -10 to 10 V. -10 to 0 V: -100% to 0% 0 to 10 V: 0% to 100% • For example, to input voltage ranging from -5 to 5 V on the O2-L terminal, set A113 to -50%, and A114 to 50%. (Example 3) Forward max. frequency (-10 V) -100% A113 A112 A111 A114 100% Analog input (02) (+10 V) Reverse max. frequency O, O2, OI Sampling •You can set the built-in filter applied to frequency setting signals of the external voltage/current input. Parameter No. Function name A016 O, O2, OI sampling Related functions Data 1 to 30 31 (with 500 ms filter +/- 0.1 Hz hysteresis) Default setting Unit 31  A011 to A016, C001 to C008 •Helps remove noise in the frequency setting circuit. •Set a larger data value if stable operation cannot be secured because of noise. Note that the larger the data value is, the slower the response time. This parameter specifies a filter time constant for a set value of 1 to 30 (× 2 ms). •When "31." is selected, a filter time constant of 500 ms and a hysteresis of ±0.1 Hz are set. (Factory default) 4-15 4-2 Function Mode Multi-step Speed Operation Function •You can set RUN speeds using codes and switch between the set speeds via the terminal. •For multi-step speed operation, you can select either 4-terminal binary operation (with 16 steps max.) or 7-terminal bit operation (with 8 steps max.). Parameter No. Function name Multi-step speed selection A020 Multi-step speed reference 0 A220 *2nd multi-step speed reference 0 A320 *3rd multi-step speed reference 0 A021 Multi-step speed reference 1 A022 Multi-step speed reference 2 A023 Multi-step speed reference 3 A024 Multi-step speed reference 4 A025 Multi-step speed reference 5 A026 Multi-step speed reference 6 A027 Multi-step speed reference 7 A028 to A035 Multi-step speed references 8 to 15 00: Binary: 16-step selection with 4 terminals 01: Bit: 8-step selection with 7 terminals Default setting Unit 00  4 6.00 0.0/Starting frequency to Max. frequency Hz 0.00 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. •During multi-step speed operation, if frequency reference selection A001 is set to the terminal (01), and the external analog input (O, O2, OI) setting mode based on a combination of O/OI selection A005, O2 selection A006, and the AT terminal is set to "reversible", the RUN command is inverted when "main frequency reference + auxiliary frequency reference" is less than zero. 4-16 Functions A019 Data 4-2 Function Mode Binary Operation •By allocating 02 to 05 (CF1 to CF4) to any of multi-function inputs 1 to 8 (C001 to C008), you can select from multi-step speeds 0 to 15. •Use A021 to A035 (multi-step speeds 1 to 15) to set frequencies for speeds 1 to 15. •When the Digital Operator is selected as the frequency reference, speed 0 is set with A020/A220/ A320 or F001 (refer to page 4-8). When the control circuit terminal block is selected, speed 0 is set with terminals O, O2, and OI. Multi-step speeds CF4 CF3 CF2 0th OFF 1st 4 OFF 2nd 3rd Functions 4th ON OFF OFF 5th ON 6th ON 7th 8th OFF 9th OFF 10th 11th 12th 13th 14th ON ON OFF ON ON 15th CF1 11th 10th OFF 9th ON OFF 4th ON 3rd 2nd OFF Frequency from the Digital Operator or the external analog input terminal 15th 0th 1st ON OFF 5th 6th 7th 12th 13th 14th 8th CF1 ON OFF ON OFF CF2 CF3 CF4 ON OFF FW ON OFF ON •For multi-step speed binary operation, you can set the wait time until which the terminal input is determined in multi-step speed/position determination time C169. This prevents the transition status before the input determination from being applied. •If no input is made after the time set in C169, the data is determined. (Note that the longer the determination time, the slower the input response.) 15 Without determination time (C169) With determination time (C169) 13 11 9 Frequency reference CF1 CF2 CF3 CF4 4-17 1 Determination time (C169) 5 4 4-2 Function Mode Bit Operation •By allocating 32 to 38 (SF1 to SF7) to any of multi-function inputs selection 1 to 8 (C001 to C008), you can select from multi-step speeds 0 to 7. •For SF1 to SF7 frequency settings, set multi-step speeds 1 to 7 (A021 to A027). Multi-step speeds SF7 SF6 SF5 SF4 SF3 SF2 SF1 0th OFF OFF OFF OFF OFF OFF OFF 1st × × × × × × ON 2nd × × × × × ON OFF 3rd × × × × ON OFF OFF SF2 4th × × × ON OFF OFF OFF SF3 5th × × ON OFF OFF OFF OFF SF4 6th × ON OFF OFF OFF OFF OFF 7th ON OFF OFF OFF OFF OFF OFF 4th 5th 3rd 6th 2nd 1st 7th 1st SF1 4 SF5 SF6 SF7 Functions • When several terminals are simultaneously turned on, priority is given to the terminal with the smallest number. The x mark in the above table indicates that speed is selected regardless of ON/OFF status. Frequency from the Digital Operator or the external analog input terminal 0th SF8 FW Jogging Operation Function •The motor rotates while this function is turned on. Parameter No. Function name A038 Jogging frequency A039 Jogging stop selection Data 0.00/Starting frequency to 9.99 00: FRS (Free running on jogging stop/ Disabled in operation) 01: DEC (Deceleration stop on jogging stop/ Disabled in operation) 02: DB (DC injection braking on joggingstop/ Disabled in operation*) 03: FRS (RUN) (Free running on jogging stop/Enabled in operation) 04: DEC (RUN) (Deceleration stop on jogging stop/Enabled in operation) 05: DB (RUN) (DC injection braking on jogging stop/Enabled in operation*) Default setting Unit 6.00 Hz 04  * When jogging stop selection A039 is set to "02" or "05", the DC injection braking settings are required. (Refer to page 4-24.) •Allocate 06 (JG) to the desired multi-function input. Jogging Frequency JG FW RV Output frequency A038 •Setting a high jogging frequency causes the Inverter to easily trip. Adjust the set value of jogging frequency A038 to prevent the Inverter from tripping. 4-18 4-2 Function Mode Jogging Stop Selection Note: To perform the jogging operation, turn on the JG terminal before the FW or RV terminal. (Do the same if the RUN command source is set to the Digital Operator.) (Example 1) (Example 2) JG JG FW 4 FW Output frequency Deceleration Normal operation Output frequency Jogging operation Free running Functions Accelerates according to the b088 setting With jogging stop selection A039 set to "00", "01", or "02", jogging does not function if the FW signal is turned on first. With A039 set to "03", "04", or "05", jogging functions even if the FW signal is turned on first. However, if the JG signal is turned off before the FW signal, the motor coasts to a free running stop. Torque Boost •Compensates for the voltage drop caused by the primary resistance of the motor, or by wiring to suppress torque reduction at a low speed range. •To select the automatic torque boost for A041/A241, set motor capacity selection H003/H203 and motor pole number selection H004/H204 according to your motor. Parameter No. Function name A041 Torque boost selection A241 *2nd torque boost selection A042 Manual torque boost voltage A242 *2nd manual torque boost voltage A342 *3rd manual torque boost voltage A043 Manual torque boost frequency A243 *2nd manual torque boost frequency A343 *3rd manual torque boost frequency H003 Motor capacity selection H203 *2nd motor capacity selection H004 Motor pole number selection H204 *2nd motor pole number selection Data Default setting Unit 00: Manual torque boost 01: Automatic torque boost 00  0.0 to 20.0 (Ratio to the value of AVR voltage selection A082) 1.0 % 0.0 to 50.0 (Ratio to base frequency) 5.0 % 0.20 to 160.0 (Ratio to base frequency) Factory default kW 4 Pole 2/4/6/8/10 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. 4-19 4-2 Function Mode Manual Torque Boost •Outputs the voltage set in A042/A242/A342 or A043/A243/A343. •In A042/A242/A342, set a ratio based on the voltage set in the motor voltage selection as 100%. Output voltage (%) 100 A042/A242/A342 4 A043/A243/A343 Base frequency (100%) Output frequency Automatic Torque Boost •If the automatic torque boost is selected in the torque boost selection (A041/A241: 01), it operates to adjust the output frequency and voltage automatically, depending on the load level. (In actual control, the automatic torque boost is used along with the manual torque boost.) •To select the automatic torque boost, set motor capacity selection H003/H203 and motor pole number selection H004/H204 correctly according to your motor. •To avoid a possible overcurrent trip during deceleration, set the AVR selection to "Always ON" (A081: 00). •If the automatic torque boost cannot provide the desired characteristics, adjust each item, as shown in the following table. Phenomenon Insufficient torque at low speed (Motor does not run at low speed.) Adjusting method Adjustment item Gradually increase the voltage setting of the manual torque boost. A042/A242 Gradually increase the slip compensation gain of the automatic torque boost. A047/A247 Gradually increase the voltage compensation gain of the automatic torque boost. A046/A246 Reduce the set value of the carrier frequency. b083 Rotation speed lowers when load is applied. Gradually increase the slip compensation gain of the automatic torque boost. A047/A247 Rotation speed increases when load is applied. Gradually reduce the slip compensation gain of the automatic torque boost. A047/A247 Gradually reduce the voltage compensation gain of the automatic torque boost. A046/A246 Gradually reduce the slip compensation gain of the automatic torque boost. A047/A247 Gradually reduce the voltage setting of the manual torque boost. A042/A242 Overcurrent trip occurs when load is applied. 4-20 Functions •If you raise the set value of the manual torque boost, be careful about motor overexcitation. Otherwise, the motor may burn out. •In manual torque boost frequency A043/A243/A343, set a ratio based on the base frequency as 100%. 4-2 Function Mode Control Method (V/f Characteristics) You can set V/f characteristics (output voltage/output frequency). Parameter No. Function name A044 V/f characteristics selection A244 *2nd V/f characteristics selection Functions 4 A344 *3rd V/f characteristics selection Data Default setting Unit Heavy duty 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) (Only A044/A244 can be set.) 03: SLV (Sensorless vector control) (Only A044/A244 can be set.*1) 04: 0SLV (0-Hz sensorless vector control) (Only A044/A244 can be set.*2) 05: V2 (Sensor vector control) (Only A044/A244 can be set.) Normal duty 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 00  Related functions A046, A246, A047, A247, A082, H003, H203, H004, H204 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. *1. Refer to "Sensorless Vector Control" (page 4-116). *2. Refer to "0-Hz Sensorless Vector Control" (page 4-117). Constant Torque Characteristics (VC) Output voltage is proportional to output frequency. While proportional from 0 Hz to base frequency, the output voltage is constant from base to maximum frequencies. Output voltage (100%) Output frequency (Hz) 0 4-21 Base frequency Max. frequency 4-2 Function Mode Special Reduced Torque Characteristics (Special VP) Suitable for a fan or pump that requires torque in a low speed range. These have VC characteristics only for low deceleration in reduced torque characteristics. Output voltage (100%) VP(f 1.7) VC Output frequency (Hz) 0 10% of base frequency a Base frequency Max. frequency c b Free V/f Setting •You can set desired V/f characteristics by setting 7 points of voltage and frequency. (b100 to b113) •The free V/f frequencies should always be 1  2  3  4  5  6  7. All the default settings are 0 Hz. You must set Free V/f setting 7 first. (Operation is disabled by factory default.) •If the free V/f setting is enabled, the functions of torque boost A041/A241, base frequency A003/ A203/A303, and maximum frequency A004/A204/A304 are disabled. (Free V/f frequency 7 is regarded as the maximum frequency.) Parameter No. Function name b100 Free V/f frequency 1 0 to Free V/f frequency 2 b102 Free V/f frequency 2 0 to Free V/f frequency 3 b104 Free V/f frequency 3 0 to Free V/f frequency 4 b106 Free V/f frequency 4 0 to Free V/f frequency 5 b108 Free V/f frequency 5 0 to Free V/f frequency 6 b110 Free V/f frequency 6 0 to Free V/f frequency 7 b112 Free V/f frequency 7 0 to 400 b101 Free V/f voltage 1 b103 Free V/f voltage 2 b105 Free V/f voltage 3 b107 Free V/f voltage 4 b109 Free V/f voltage 5 b111 Free V/f voltage 6 b113 Free V/f voltage 7 Related functions Data 0.0 to 800.0 Description Set frequencies for each break point. Default setting Unit 0 Hz Set output voltages 0.0 for each break point. * V A044, A244, A344 4-22 4 Functions Period a: Provides constant torque characteristics within a range from 0 Hz to 10% of the base frequency. (Example) If the base frequency is 50 Hz, the Inverter provides constant torque characteristics within a range from 0 to 5 Hz. Period b: Provides reduced torque characteristics within a range from 10% to 100% of the base frequency. The Inverter outputs voltage based on a curve of the 1.7th power of the frequency. Period c: Provides constant voltage characteristics within a range from the base frequency to the maximum frequency. 4-2 Function Mode (Example) Output voltage (V) V7 V6 V5 V4 V1 V2, V3 Output frequency (Hz) 4 0 f1 f2 f3 f4 f5 f6 f7 Functions * Even if free V/f voltages 1 to 7 are set to 800 V, the Inverter cannot output voltage higher than the input voltage or the value of the motor voltage selection. Use thorough caution to verify that the output characteristic setting is proper. An improper setting causes overcurrent during acceleration or deceleration, or vibration of the motor and/or machine. Output voltage (V) V7 Select the voltage or motor voltage available for output. V6 0 4-23 f6 f7 Output frequency (Hz) 4-2 Function Mode Output Voltage Gain •Changes the Inverter output voltage, based on the voltage selected in AVR voltage selection A082 as 100%. •You can avoid motor hunting by reducing the output voltage gain. Parameter No. A045 Function name Data Output voltage gain Default setting Unit 100 % 20 to 100 Related functions A082 AVR voltage selection (A082) 4 A045 Functions Max. frequency (A004/A204/A304) Base frequency (A003/A203/A303) DC Injection Braking •DC injection braking is applied to the motor depending on the motor load. •Two methods are available for DC injection braking: One is the external method via the multifunction input terminal; the other is the internal method performed automatically to start/stop the motor. Even if DC injection braking is used, however, the motor may not stop depending on the moment of inertia of the motor load. Parameter No. Function name Data Default setting Unit A051 DC injection braking selection 00: OFF (Disabled) 01: ON (Enabled) 02: ON (FQ) (Frequency control [A052 set value]) 01  A052 DC injection braking frequency 0.00 to 400.00 0.50 Hz A053 DC injection braking delay time 0.0 to 5.0 0.0 s A054 DC injection braking power 0 to 100 (0.4 to 55 kW) 50 0 to 80 (75 to 132 kW) 40 0.0 to 60.0 0.5 s  % A055 DC injection braking time A056 DC injection braking method selection 00: Edge operation 01: Level operation 01 Startup DC injection braking power 0 to 100 (0.4 to 55 kW) 0 A057 0 to 80 (75 to 132 kW) 0 A058 Startup DC injection braking time A059 DC injection braking carrier frequency Related functions % 0.0 to 60.0 0.0 0.5 to 15.0 (0.4 to 55 kW) 5.0 0.5 to 10.0 (75 to 132 kW) 3.0 s Hz C001 to C008 4-24 4-2 Function Mode DC Injection Braking Carrier Frequency You can set a DC injection braking carrier frequency in A059. Note that setting a 5 kHz or higher frequency automatically reduces the braking power. Refer to the following figure (DC injection braking power limit). 10 9 8 7 6 Max. braking power 5 4 3 2 1 Functions 4 (75) (46) (34) (22) (10) 3 5 7 9 11 13 15 DC injection braking carrier frequency DC Injection Braking Power Limit External DC Injection Braking •Allocate 07 (DB) to any of multi-function inputs C001 to C008. •DC injection braking can be applied by turning on/off the DB terminal, regardless of DC injection braking selection A051. •Set a braking power level in DC injection braking power A054. •If DC injection braking delay time A053 is set, the Inverter output is shut off during the set time period and the motor goes into free-run status. After the set time elapses, DC injection braking starts. •Set DC injection braking time A055 via the Digital Operator or the DB terminal while taking into account motor heat generation. •Perform each setting according to your system after setting DC injection braking method selection A056. (a) Edge operation (A056: 00) (Example 1-a) (b) Level operation (A056: 01) (Example 1-b) FW FW DB DB Output frequency Output frequency A055 (Example 2-a) (Example 2-b) FW FW DB DB Output frequency Output frequency A055 4-25 4-2 Function Mode (a) Edge operation (A056: 00) (Example 3-a) (b) Level operation (A056: 01) (Example 3-b) FW FW DB DB Output frequency Free running A053 Output frequency Free running A053 A055 4 Internal DC Injection Braking (A051: 01) Edge operation: Giving priority to DC injection braking time A055, performs DC injection braking for the set time in A055. DC injection braking operates for the set time in A055 when the output frequency reaches the set value in A052 after the RUN command (FW) is turned off. Even if the RUN command is turned on during DC injection braking, the latter is effective during the set time in A055. (Example 5-a), (Example 6-a) Level operation: Giving priority to the RUN command, shifts to normal operation, ignoring DC injection braking time A055. When the RUN command is turned on during DC injection braking, returns to normal operation, ignoring the set time in A055. (Example 5-b), (Example 6-b) (a) Edge operation (b) Level operation (i) During startup (example 4-a) (ii) During startup (example 4-b) FW FW Output frequency Output frequency A057 A057 A058 A058 4-26 Functions •DC injection braking is applied without terminal operation at start/stop of the Inverter. To use internal DC injection braking, set DC injection braking selection A051 to 01. •Set the startup DC injection braking power in A057. In A058, set the startup DC injection braking time, regardless of the edge or level operation. (Example 4-a), (Example 4-b) •Set DC injection braking power A054 to define the braking power other than at startup. •Set the DC injection braking starting frequency in DC injection braking frequency A052. •Once DC injection braking delay time A053 is set, the Inverter stops output when the frequency reaches the A052 value after the RUN command (FW) has been turned off. During the set time in A053, the motor remains in free-run status. After the set time in A053, DC injection braking starts. •Edge and Level operations for internal DC injection braking work differently when the RUN command switches from STOP to RUN. 4-2 Function Mode (a) Edge operation (ii) During stop (example 5-a) (ii) During stop (example 5-b) FW FW Free running Output frequency A052 A053 A052 A053 A055 (iii) During stop (example 6-b) FW FW Output frequency Output frequency A052 4-27 Free running Output frequency A055 (iii) During stop (example 6-a) Functions 4 (b) Level operation A055 A052 A055 4-2 Function Mode Internal DC Injection Braking (Operates Only at the Set Frequency) (A051: 02) •DC injection braking can be applied when the output frequency becomes lower than the DC injection braking frequency (A052). •Neither (2) external nor (3) internal DC injection braking is available while this function is selected. •Operates only when the RUN command is turned on. •DC injection braking starts when both the reference and current frequencies become lower than A052. (Example 7-a) •When the reference frequency exceeds the A052 set value by 2 Hz or more, DC injection braking is released and the output returns to normal. (Example 7-a) •If the reference frequency is "0" when the operation starts with analog input, the initial operation is DC injection braking because both the reference and current frequencies are "0". (Example 7-b) •If the RUN command is turned on with the frequency reference established (or a value larger than the A052 setting is input), the initial operation is set to normal output. (Example 7-a) 4 (Example 7-b) RUN command A052 Frequency reference A052 Frequency reference Output frequency Output frequency Functions ON ON RUN command •The operation to return to normal varies depending on the setting of DC injection braking power A054. (a) Edge operation (b) Level operation ON ON RUN command RUN command A052 Frequency reference A052 Frequency reference Output frequency Output frequency A053 Frequency Limit •You can set both the upper/lower limits to the output frequency. Parameter No. Function name Data Default setting A061 Frequency upper limit 0.0/Frequency lower limit [A062] to Max. frequency [A004] 0.00 A261 *2nd frequency upper limit 0.0/2nd frequency lower limit [A262] to 2nd max. frequency [A204] 0.00 A062 Frequency lower limit 0.0/Starting frequency to Frequency upper limit [A061] 0.00 A262 *2nd frequency lower limit 0.0/Starting frequency to 2nd frequency upper limit [A261] 0.00 Unit Hz Related functions C001 to C008 4-28 4-2 Function Mode * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. •Does not accept any frequency reference beyond the upper/lower limits. •Set the upper limit first. Make sure that the upper limit (A061/A261) is larger than the lower limit (A062/A262). •Make sure that the upper and lower limiter settings do not exceed the maximum frequency (A004/ A204/A304). •Make sure that the output frequency (F001) and multi-step speeds 1 to 15 (A021 to A035) are not lower than the lower limit setting and not higher than the upper limit setting. •Neither limit works if set to 0 Hz. •Disabled when the 3rd control is selected. 4 When Using O-L and OI-L • Once the lower limit is set, the Inverter outputs the frequency (A062) set for the lower limit, if 0 V (4 mA) is input to the frequency reference. Functions Output frequency (Hz) Max. frequency A004/A204 A061 A062 10 V 20 mA 0V 4 mA Frequency reference When Using O2-L • When the lower limit is used for the O2 input, the rotation at 0 V is fixed to A062 for either forward or reverse rotation, as described below. Max. frequency A004/A204 A061 Reverse -10 V A062 Forward A062 10 V A061 Max. frequency A004/A204 (a) When the RUN command is set to the terminal (A002: 01) Terminal Rotation when O2 = 0 V FW (ON) A062 for forward rotation RV (ON) A062 for reverse rotation (a) When the RUN command is set to the Digital Operator (A002: 02) 4-29 F004 Rotation when O2 = 0 V 00 A062 for forward rotation 01 A062 for reverse rotation 4-2 Function Mode Frequency Jump Function •The frequency jump function helps avoid resonant points of loaded machines. Parameter No. Function name A063 A065 A067 Jump frequency 1 Jump frequency 2 Jump frequency 3 A064 A066 A068 Jump frequency width 1 Jump frequency width 2 Jump frequency width 3 Data Default setting 0.00 to 400.00 Unit 0.00 Hz 0.00 to 10.00 0.50 Related functions C001 to C008 4 Output frequency A068 A068 A067 A066 A065 A063 A066 A064 A064 Frequency reference Acceleration Stop Function •When the moment of inertia of a machine load is large, this function delays acceleration until the motor starting slip is reduced. Use this function, if an overcurrent trip occurs during startup. •Does not depend on acceleration pattern selection A097, and works with all acceleration patterns. Parameter No. Function name A069 Acceleration stop frequency A070 Acceleration stop time Data Default setting Unit 0.00 to 400.00 0.00 Hz 0.0 to 60.0 0.0 s Output frequency A069 A070 Frequency reference 4-30 Functions •You cannot set output frequencies within a jump frequency setting range, where the frequency jump function avoids steady operation. •The output frequency fluctuates continuously according to the acceleration/deceleration time during both actions. You can set up to three points for the jump frequency. 4-2 Function Mode PID Function •This function enables process control of such elements as flow rate, air volume, and pressure. Parameter No. Functions 4 Function name Data Default setting Unit 00: OFF (Disabled) 01: ON (+) (Enabled) 02: ON (+/-) (Reverse output enabled) 00  A071 PID selection A072 PID P gain 0.2 to 5.0 1.0  A073 PID I gain 0.0 to 3600.0 1.0 s A074 PID D gain 0.00 to 100.00 0.00 s A075 PID scale 0.01 to 99.99 1.00 Time PID feedback selection 00: OI 01: O 02: Modbus (RS485 communication) 03: Pulse (Pulse train frequency) 10: Math (Operation function output) 00  A077 Reverse PID function 00: OFF (Deviation = Target value - Feedback value) 01: ON (Deviation = Feedback value - Target value) 00  A078 PID output limit function 0.0 to 100.0 0.0 % PID feedforward selection 00: Disabled 01: O 02: OI 03: O2 00  PID deviation excessive level 0.0 to 100.0 3.0 % 100.0 % 0.0 % A076 A079 C044 C052 PID FB upper limit C053 PID FB lower limit 0.0 to 100.0 Related functions d004, A001, A005, A006, C001 to C008, C021 to C025 •To use this function, set A071 to "01" or "02". •You can disable the PID operation in progress using an external signal. To use this function, allocate "23" (PID: PID disabled) to any of the multi-function inputs. While the PID terminal is turned on, the Inverter disables the PID function and outputs normally. •You can limit the PID output under various conditions. Basic Structure of PID Control (Example) Feedforward Target value + 0 to 10 V 4 to 20 mA Deviation  Feedback Kp 1 + 1 Ti s + Td s + - Disabled 0 to 10 V 4 to 20 mA -10 to 10 V Control volume Normal control of the Inverter fs Transducer 0 to 10 V 4 to 20 mA Kp: Proportional gain 4-31 Sensor M Ti: Integral time Td: Derivative time s: Operator : Deviation 4-2 Function Mode PID Operation P Operation •Operation where the control volume is proportional to the target value Step transition Ramp transition Target value Control volume Large Large A072 A072 Small Small I Operation 4 •Operation where the control volume increases linearly according to time Small Small A073 A073 Control volume Large Large Functions Target value D Operation •Operation where the control volume is proportional to the variation ratio of the target value Target value Large Large A074 A074 Control volume Small Small •PI operation is the combination of the above P and I operations; PD is P and D operations; PID is P, I and D operations. Feedback Selection •Select a terminal used for feedback signals in PID feedback selection A076. •The target value depends on the terminal selected in frequency reference selection A001 other than that in A076. When A001 is set to "01" (terminal), the setting of O/OI selection A005 is disabled. •When analog input is selected for PID feedback and A001 is set to "01" (terminal), the PID target value is selected depending on the A006 set value, as shown in the following table. PID target value PID feedback selection (A076) A006 = 00 A006 = 01 A006 = 02 A006 = 03 00 (OI-L) O + O2 (Not reversible) O + O2 (Reversible) O 01 (O-L) OI + O2 (Not reversible) OI + O2 (Reversible) OI OI included in operands O + O2 (Not reversible) O + O2 (Reversible) O 10 O included in operands (operation result) OI and O are the operands OI + O2 (Not reversible) OI + O2 (Reversible) OI O2 (Reversible) •To select RS485 for PID feedback, transfer data as described below. 4-32 4-2 Function Mode Transfer data using "command 01". To transfer feedback data, set the most significant byte of frequency data to "1". (Example) To send 5 Hz: Transmission data is "set value × 100" and expressed in 6 bytes  "000500" Set the most significant byte to "1".  "100500" ASCII conversion  "31 30 30 35 30 30" Note: With ASCII data, the set value is frequency (Hz). Write data in holding register address 0006h. (100% = 10000) Functions 4 Register No. Function name Function code R/W Monitor data and setting parameters Data resolution 0006h PID feedback  R/W 0 to 10000 0.01 [%] Note: You can read and write data. However, you can read data only when ModBus-RTU is selected for the PID feedback. Data cannot be read under other settings. •If "03" (pulse train input) is set for PID feedback A076, the Inverter obtains a percent conversion result (100% at max. frequency) as a feedback value, relative to the input pulse train frequency value (Hz). Feedforward Selection •Select a terminal used for feedforward signals in PID feedforward selection A079. •The A079 setting is enabled even if the terminal selected in A079 is duplicated with the terminal selected for target value or feedback value input. •If A079 is set to "disabled", feedforward control is disabled. Reverse PID Function Depending on the sensor characteristics, the polarity of deviation between the target and feedback values may not match the Inverter's command. In this case, you can invert the deviation polarity by setting A077 to "01". (Example) To control a refrigerator compressor: If the specified temperature range of a temperature sensor is -20C to 100C at 0 to 10 (V), the target value is 0C, and the current temperature is 10C, the Inverter reduces the frequency under normal PID control since the feedback value is higher than the target value.  Set A077 to "01" so that the Inverter increases the frequency. A077 PID target value PID operation -1 PID feedback value 4-33 4-2 Function Mode PID Output Limit Function •This function limits PID output within a variable range relative to the target value. •To use this function, set PID output limit function A078. The output frequency will be limited within a range of "target value ± (A078)", with the maximum frequency defined as 100%. •With A078 set to 0.0, this function is disabled. PID output (%) PID output range PID target value PID variable range (A078) PID variable range (A078) 4 Time (s) •When a PID operation result is a negative value under normal PID control, the frequency reference to the Inverter is limited at 0 Hz. However, if PID selection A071 is set to "02" (reverse output enabled), reverse output can be provided for the Inverter when the PID operation result is a negative value. •When A071 = 02, the above-mentioned PID variable range limit function and the PID output stop function are disabled. PID Gain Adjustment •If a stable response cannot be obtained in PID function operation, adjust each gain as follows according to the situation. •Feedback value variation is slow when the target value is changed. •The feedback value changes fast but isn't stable. •The target and feedback values wouldn't match smoothly. •The feedback value fluctuates unstably. •Response is slow even with P gain raised. •With P gain raised, the feedback value vibrates and isn't stable.  Raise P gain A072.  Lower P gain A072.  Lower I gain A073.  Raise I gain A073.  Raise D gain A074.  Lower D gain A074. Excessive Deviation/Output •You can set PID deviation excessive level C044 during PID control. With this function allocated, the multi-function output terminal is turned on when the PID deviation  reaches the set level in C044. •C044 can be set from 0 to 100. The setting corresponds to the range of 0 to the maximum target value. •Allocate 04 (OD) to any of multi-function output terminals C021 to C025 or relay output terminal C026. Feedback Comparison Signal •If a PID feedback value is out of the specified range, it can be output to a multi-function output terminal. •Allocate 31 (FBV) to any of multi-function output terminals C021 to C025 or relay output terminal C026. 4-34 Functions PID Reverse Output 4-2 Function Mode C052 (OFF level) PID feedback C053 (ON level) Time Functions 4 FW ON OFF FBV ON OFF PID Feedback Value Monitor •You can monitor the PID feedback value. •The monitor value is displayed as the product of the feedback value and PID scale A075. "Monitor display" = "Feedback value (%)" × "A075 setting" PID Integral Reset •Clears the integral value of PID operation. •Allocate 24 (PIDC) to any of multi-function inputs C001 to C008. •Clears the integral value every time the PIDC terminal is turned on. Do not turn on the PIDC terminal during PID operation to avoid a possible overcurrent trip. Turn on the PIDC terminal after turning off PID operation. AVR Function •This function outputs voltage to the motor correctly even if the incoming voltage to the Inverter fluctuates. With this function, output voltage to the motor is based on the voltage set in the motor voltage selection. Parameter No. Function name A081 AVR selection A082 AVR voltage selection Data Default setting Unit 02  200/400  00: Always ON 01: Always OFF 02: OFF during deceleration 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 Related functions d004, A001, A005 •With A081 (AVR selection), set whether to enable or disable this function. •Note that the Inverter cannot output voltage beyond that of the incoming voltage. •To avoid a possible overcurrent trip during deceleration, set the AVR selection to "Always ON" (A081: 00). Parameter No. Data Description Note 00 Always ON Enabled during acceleration, constant speed , and deceleration. 01 Always OFF Disabled during acceleration, constant speed, and deceleration. 02 OFF during deceleration Disabled only during deceleration in order to reduce the energy regenerated to the Inverter by increasing the motor loss. This will avoid a possible trip due to regeneration during deceleration. A081 4-35 4-2 Function Mode Automatic Energy-saving Operation Function •This function automatically minimizes the Inverter output power during constant speed operation, and is suitable for load with reduced torque characteristics (e.g. fan, pump). Parameter No. Function name A085 RUN mode selection A086 Energy-saving response/ accuracy adjustment Data 00: Normal operation 01: Energy-saving operation 02: Automatic operation 0.0 to 100.0 Default setting Unit 00  50.0 % Parameter No. Function name A086 Energy-saving response/ accuracy adjustment Data Response Accuracy 0.0 Slow High 100.0 Fast Low Automatic Optimum Acceleration/Deceleration •The automatic acceleration/deceleration function eliminates the need for acceleration/deceleration settings during Inverter operation. Parameter No. Function name A085 RUN mode selection Related functions Data 00: Normal operation 01: Energy-saving operation 02: Automatic operation Default setting Unit 00  A044, A244, A344, b021, b024, b022, b025 •Conventionally, the user had to set an Inverter acceleration/deceleration time depending on the actual load conditions. However, this function can automatically set an acceleration/deceleration time, making full use of the Inverter's capacity. The acceleration time is a time during which acceleration is performed within a current value set in the overload limit parameter (when the overload limit function is enabled), or within approx. 150% of the rated current (when the overload limit function is disabled). The deceleration time is a time during which deceleration is performed within approx. 150% of the rated current value, or within a DC voltage in the Inverter circuit of approx. 370 V (200V-class) or approx. 740 V (400 V-class). Thus, the Inverter enables real-time response to a change in applied load and inertia, and sets acceleration/deceleration time automatically. • Note the following before use: Note 1: This function is not suitable for a machine that needs a fixed acceleration/deceleration time. Acceleration/deceleration time varies depending on applied load and inertia. Note 2: If the machine inertia exceeds approx. 20 times that of the motor shaft, the Inverter may trip. In this case, reduce the carrier frequency. Note 3: Acceleration/deceleration time varies depending on fluctuations in current value, even with the same motor. Note 4: The automatic optimum acceleration/deceleration setting is enabled only during V/f control. When sensorless vector control is selected, the Inverter performs normal operation. 4-36 4 Functions •To operate with this function, set RUN mode selection A085 to "01". You can adjust the response and accuracy with energy-saving response/accuracy adjustment A086. •Controls the output power at a comparatively slow rate. Should rapid load fluctuation like impact load occur, the motor may stall, resulting in an overcurrent trip. 4-2 Function Mode Note 5: If the jogging operation is performed when the automatic operation is selected, the Inverter performs automatic acceleration, which is different from normal jogging operation. Note 6: When the applied load is larger than the rating, deceleration time may be prolonged. Note 7: If acceleration and deceleration are frequently repeated, the Inverter may trip. Note 8: When the internal braking circuit is used, or when the regenerative braking unit is externally installed, the motor cannot stop within the specified deceleration time because of braking resistance. In this case, do not use the automatic optimum acceleration/deceleration function. Note 9: When using a lower rank motor size than specified for the Inverter, enable the overload limit function (b021), and set the overload limit level (b022) to 1.5 times the rated current of the motor. Functions 4 2-step Acceleration/Deceleration Function •By setting this function, you can change the acceleration/deceleration time during acceleration/ deceleration. Parameter No. Function name A092 Acceleration time 2 A292 *2nd acceleration time 2 A392 *3rd acceleration time 2 s A093 Deceleration time 2 s A293 *2nd deceleration time 2 A393 *3rd deceleration time 2 A094 2-step acceleration/ deceleration selection A294 Data 2-step acceleration frequency A295 *2nd 2-step acceleration frequency A096 2-step deceleration frequency A296 *2nd 2-step deceleration frequency Related functions Unit s 0.01 to 3600.00 0.01 to 3600.00 10.00 10.00 s s s 00: 2CH-Terminal (Switched via multifunction input 09 (example 1) 01: Preset FQ (Switched by setting) (example 2) *2nd 2-step acceleration/ 02: FWD-REV (Enabled only when deceleration selection switching forward/reverse (example 3) A095 Default setting 00  0.00 to 400.00 0.00 Hz 0.00 to 400.00 0.00 Hz F002, F202, F302, F003, F203, F303, C001 to C008 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. 4-37 4-2 Function Mode •Select an acceleration/deceleration time switching method from the following three: Switching via a multi-function input Automatic switching at a specified frequency Automatic switching only when switching between forward/reverse If the 3rd control function is selected, however, switching by the 2-step acceleration/deceleration frequency is disabled. •To switch via a multi-function input, allocate 09 (2CH) to any of C001 to C008. (Example 1) When A094/A294 is set to 00 (Example 2) When A094/A294 is set to 01 FW FW 4 2CH Acceleration 2 Functions A095/A295 Deceleration 2 A096/A296 Acceleration 1 Deceleration 1 Output frequency Output frequency Acceleration time 1 Acceleration time 2 F002/F202/ A092/ A292/ F302 A392 Deceleration Deceleration time 2 time 1 Acceleration time 1 A093/A293/ F003/F203/ A393 F303 Acceleration time 2 F002/F202 A092/ A292 Deceleration Deceleration time 2 time 1 A093/ F003/F203 A293 (Example 3) When A094/A294 is set to 02 FW 2CH Output frequency Acceleration time 2 Deceleration time 1 A092/A292/ A392 F003/F203/ F303 Acceleration time 1 Deceleration time 2 F002/F202/ F302 A093/A293/ A393 Acceleration/Deceleration Pattern •Acceleration/deceleration pattern can be set for each system. Parameter No. Function name A097 Acceleration pattern selection A098 Deceleration pattern selection A131 Acceleration curve parameter A132 Deceleration curve parameter Data Default setting Unit 00: Line 01: S-curve 02: U-curve 03: inv. U curve 04: EL-S curve 01  01 (small curve) to 10 (large curve) 02  4-38 4-2 Function Mode Parameter No. Function name A150 EL-S-curve ratio 1 during acceleration A151 EL-S-curve ratio 2 during acceleration A152 EL-S-curve ratio 1 during deceleration A153 EL-S-curve ratio 2 during deceleration Default setting Unit 0 to 50 10 % 0 to 50 10 % •To select an acceleration or deceleration pattern, use A097 or A098, respectively. •You can set acceleration and deceleration patterns individually. •If any item other than "Line" (A097/A098 = 00) is selected for the acceleration/deceleration pattern, the acceleration/deceleration time is prolonged when this function is used with analog input (A001 = 01). 4 Pattern Selection Select an acceleration/deceleration pattern with reference to the following table. Set values 02 03 04 Line S shape U shape Inverted U shape EL-S shape Time Accelerates/ Decelerates linearly before Description reaching the set output frequency value. 4-39 Output frequency Output frequency Time Helps prevent the collapse of cargo on the elevating machine or conveyor. Time Time Output frequency Output frequency Output frequency Output frequency A098 (Deceleration) Time Time Time Time Output frequency 01 Output frequency A097 (Acceleration) 00 Output frequency Parameter No. Output frequency Functions Data Time Time Helps with tension control and roll break Provides shockless prevention (for a winding machine, etc.). start/stop as with the S pattern, but the intermediate section is linear. 4-2 Function Mode Pattern Curve Parameter (Curve Factor) •Determine a curve factor with reference to the figures below. Output frequency (Hz) Target frequency (100%) 96.9 82.4 Output frequency (Hz) 10 02 Target frequency (100%) 99.6 93.8 87.5 68.4 64.6 Output frequency (Hz) Target frequency (100%) 10 65 02 35 17.6 35.4 31.6 10 10 25 50 75 Time Acceleration time before reaching the output frequency set value (100%) 25 50 10 12.5 6.25 0.39 02 3.1 02 75 4 25 Time 50 75 Time Acceleration time before reaching the output frequency set value (100%) Acceleration time before reaching the output frequency set value (100%) EL-S Curve Ratio If the EL-S pattern is used, you can set a curve ratio (A151 to A153) individually for acceleration and deceleration. If all settings are "50 (%)", the Inverter operates in the same manner as with the S curve. Output frequency ratio (%) 100 Curve ratio 2 during acceleration (A151) Curve ratio 1 during deceleration (A152) 50 Curve ratio 2 during deceleration (A153) Curve ratio 1 during acceleration (A150) Time(s) 4-40 Functions •The S pattern has an intermediate section where acceleration/deceleration time is shortened. •If LAD cancel (LAC) is selected for a multi-function input and that input is turned on, the acceleration/deceleration pattern is ignored, and the output frequency instantaneously follows the reference frequency. 4-2 Function Mode Operation Frequency Function •Two systems of frequency reference operation results are available for the frequency reference and PID feedback value. Functions 4 Parameter No. Function name A141 Operation frequency input A setting A142 Operation frequency input B setting A143 Operator selection Data Default setting Unit 02  03  00  00: Operator (Digital Operator (F001)) (A020/A220/A320) 01: VR (Digital Operator (FREQ adjuster)) (Enabled when 3G3AX-OP01 is used.) 02: O (Input O) 03: OI (Input OI) 04: Modbus (RS485 communication) 05: Option 1 06: Option 2 07: Pulse (Pulse train frequency) 00: ADD (Addition (A + B)) 01: SUB (Subtraction (A - B)) 02: MUL (Multiplication (A × B)) Related functions A001 = 10, A076 = 10 Note 1: When this function is enabled, the Up/Down function cannot be used. In addition, frequency cannot be changed through key operations from output frequency monitor d001, frequency conversion monitor d007, or output frequency setting F001. Note 2: The same setting is available in A141 and A142. •To use this function as a frequency reference, set frequency reference selection A001 to "10". •To use this function as a PID feedback, set PID feedback selection A076 to "10". Frequency Addition Function •The value set in frequency addition amount A145 can be added to or subtracted from the selected frequency reference value. •To use this function, allocate 50 (ADD) to any of the multi-function inputs. The A145 value is added or subtracted with the ADD terminal turned on. Parameter No. Function name A145 Frequency addition amount 0.00 to 400.00 A146 Frequency addition direction 00: ADD (Add A145 value to output frequency) 01: SUB (Subtract A145 value from output frequency) Related functions Data Default setting Unit 0.00 Hz 00  C001 to C008, ADD input Note 1: If the sign of the frequency reference is changed ((-)  (+), or (+)  (-)) as a result of operation, the rotation direction will be inverted. Note 2: When the PID function is used, the frequency addition function is enabled for a PID target value. (Note that A145 is displayed in % (in increments of 0.01%).) 4-41 4-2 Function Mode Momentary Power Interruption/Trip Retry (Restart) Restart During Momentary Power Interruption Parameter No. Function name Data Default setting Unit b001 Retry selection*4 *6 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) (example 1) *3 03: f-match Trip (Trip after frequency matching deceleration stop) *1 *3 04: Actv. f-match (Active Frequency Matching restart (example 1) *3 00  b002 Allowable momentary power interruption time 0.3 to 25.0: If the momentary power interruption is within the set time, the Inverter follows the setting in b001. 1.0 s b003 Retry wait time 0.3 to 100.0 Time before restart 1.0 s b004 Momentary power interruption/ undervoltage trip during stop selection *2 *4 00: OFF (Disabled) 01: ON (Enabled) 02: Decel-OFF (Disabled during stop and deceleration stop) 00  b005 Momentary power interruption retry time selection 00: 16 times 01: No limit 00  b007 Frequency matching lower limit frequency setting 0.00 to 400.00 When the motor free-running frequency falls below this lower limit frequency, the Inverter restarts at 0 Hz (examples 3 and 4) 0.00 Hz 00  b008 *7 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) b009 Undervoltage retry time selection 00: 16 times 01: No limit 00  b010 Overvoltage/ overcurrent retry time selection 1 to 3 Select the number of retry times in the event of overvoltage/overcurrent *5 3 Time b011 Trip retry wait time 0.3 to 100.0 Time before restart 1.0 s Trip retry selection 4-42 4 Functions •You can set whether the Inverter trips or retries (restarts) when a momentary power interruption or undervoltage occurs. •If the retry function is selected in retry selection b001, the Inverter retries for the number of times set in b005 (for momentary power interruption) or b009 (for undervoltage), and trips on the next time. (Under the limitless retry setting, the Inverter doesn't trip.) •You can use b004 to select whether the Inverter trips or not when a momentary power interruption or undervoltage occurs during stop. •When selecting the retry function, set retry condition b008 according to your system. •If undervoltage is retained for 40 seconds even during retry operation, it results in E09 (undervoltage trip). 4-2 Function Mode Parameter No. Data b028 Active Frequency Matching restart level 0.20 × Rated current to 2.00 × Rated current (0.4 to 55 kW) 0.20 × Rated current to 1.80 × Rated current (75 to 132 kW) Current limit level at Active Frequency Matching restart b029 Active Frequency Matching restart parameter 0.10 to 30.00 Frequency reduction time at Active Frequency Matching restart b030 Starting frequency at Active Frequency Matching restart 00: Off FQ (Frequency at interruption) 01: Max.FQ (Max. Frequency) 02: Set FQ (Set Frequency) Related functions 4 Functions Function name Default setting Unit Rated current A 0.50 s 00  C021 to C025, C026 *1. If an overvoltage/overcurrent trip occurs during deceleration, momentary power interruption error E16 appears, and the motor goes into free-run status. In this case, increase the deceleration time. *2. When direct current (P-N) is supplied to control power supply terminal Ro-To, the Inverter may detect undervoltage at power interruption and then trip. If there is any problem with your system, set "00" or "02". *3. The Inverter may start at 0 Hz if: The output frequency is equal to or lower than 1/2 of the base frequency The motor induction voltage quickly attenuates *4. Even if retry selection b001 is set to "Retry" (01 to 03) and selection of momentary power interruption/ undervoltage trip during stop b004 is set to "Disabled" (00 or 02), the Inverter trips when the actual momentary power interruption time exceeds the allowable momentary power interruption time. (Example 2) *5. Even if the trip retry operation is selected, the Inverter trips if the cause of the trip is not remedied after the retry wait time (b003) elapses. In this case, increase the retry wait time. *6. Even if the retry operation is selected, the Inverter trips when undervoltage remains for 40 seconds or longer. *7. If frequency matching start or Active Frequency Matching restart is selected for retry operation, the Inverter abruptly restarts at power-on, by alarm reset or retry start. •Below is the timing chart for frequency matching start (retry selection b001 = 02). Note that the Inverter switches, regardless of settings, to the initial state when the power supply is turned on in the case of a complete power discharge. t0: Momentary power interruption time t1: Allowable momentary power interruption time (b002) t2: Retry wait time (b003) (Example 1) Duration of momentary power interruption < Allowable duration of momentary power interruption (b002) (Example 2) Duration of momentary power interruption > Allowable duration of momentary power interruption (b002) Power supply Power supply Inverter output Inverter output Free running Motor rpm Motor rpm t0 t2 t1 4-43 Free running t0 t1 4-2 Function Mode (Example 4) Motor frequency (rpm) < b007 (Example 3) Motor frequency (rpm) > b007 Power supply Power supply Inverter output Inverter output Free running Free running b007 b007 Motor frequency (rpm) Frequency matching start t0 Motor frequency (rpm) t0 t2 t2 0-Hz start 4 Alarm Output for Momentary Power Interruption/Undervoltage During Stop (Example 5) b004: 00 Inverter is stopped ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Power supply (Example 6) b004: 01 Power supply Inverter is stopped (Example 7) b004: 02 Power supply Inverter is stopped ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Inverter is running ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Power supply Inverter is running ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Power supply Inverter is running ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Power supply 4-44 Functions •Use b004 to select whether to enable an alarm output in case of momentary power interruption or undervoltage. •An alarm output continues while Inverter control power supply remains. Alarm output for momentary power interruption/undervoltage during stop Standard (examples 5 to 7) Operation where DC (P-N) is supplied to control power supply terminal Ro-To (examples 8 to10) 4-2 Function Mode (Example 8) b004: 00 Inverter is stopped Inverter is running ON Power supply OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Inverter is stopped (Example 9) b004: 01 Power supply Functions 4 ON Power supply OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Inverter is running ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) Power supply Undervoltage Inverter is stopped (Example 10) b004: 02 Power supply Inverter is running ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF Signal during momentary ON OFF power interruption (IP) ON OFF ON RUN command OFF ON Inverter output OFF ON Alarm OFF ON Signal during momentary OFF power interruption (IP) Power supply Note 1: You can allocate the momentary power interruption signal (IP: 08) and the undervoltage signal (UV: 09) to any of multi-function output terminals 11 to 15 selection (C021 to C025) or the relay output terminal (C026). Note 2: If power interruption is retained for 1 second or longer, refer to the reset description ("Reset" (page 4-87)). Restarting Procedure •Frequency matching restart This method restarts the Inverter by detecting frequency and rotation direction based on the motor's residual voltage. •Active Frequency Matching restart The Inverter starts output at the frequency set in starting frequency selection b030, and searches for a point where frequency and voltage are balanced to restart the Inverter, while holding current at the Active Frequency Matching restart level (b028). If the Inverter trips with this method, reduce the b028 set value. FW FRS b028 Output current Decelerates according to b029 Inverter output frequency Frequency selected in b030 Motor rotation speed 4-45 b003 4-2 Function Mode Input Power Supply Phase Loss Protection Function Selection •This function outputs an alarm when the Inverter's input power supply has phase loss. Parameter No. Function name b006 Input phase loss protection selection Data Default setting Unit 00  00: OFF (Disabled) 01: ON (Enabled) Phase loss may cause the Inverter to fail, as follows: •The main capacitor ripple current increases, resulting in remarkable reduction in the capacitor's service life. •When load is applied, the Inverter's internal converter or thyristor may be damaged. 4 Electronic Thermal Function Parameter No. Function name b012 Electronic thermal level b212 *2nd electronic thermal level b312 *3rd electronic thermal level b013 Electronic thermal characteristics selection b213 *2nd electronic thermal characteristics selection b313 *3rd electronic thermal characteristics selection b015 Free setting, electronic thermal frequency 1 b017 Free setting, electronic thermal frequency 2 b019 Free setting, electronic thermal frequency 3 b016 Free setting, electronic thermal current 1 b018 Free setting, electronic thermal current 2 b020 Free setting, electronic thermal current 3 C061 Thermal warning level Related functions Data Default setting Unit Rated current A 00  0.00 to 400.00 0.00 Hz 0.0 to Rated current 0.0 A 0 to 100 *1 80 % 0.20 × Rated current to 1.00 × Rated current 00: Reduced TRQ (Reduced torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting) C021 to C025, C026 * To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it on. *1. Set a percentage relative to the electronic thermal multiplication value. When the value reaches 100%, an overload trip (E05) occurs. 4-46 Functions •Causes a trip to protect the motor from overheating. Set this according to the motor rated current. •Provides the most appropriate protection characteristics, taking into account the decline of the motor cooling capability at a low speed. •Outputs an alarm signal before an electronic thermal trip. •Rated values will be affected by the HD, ND selection. 4-2 Function Mode Electronic Thermal Level (Motor Protection Level) (Example) 3G3RX-A2150 Rated current: 64 A Setting range: 12.8 A (20%) to 64.0 A (100%) • The graph on the right shows the time limit characteristics with the electronic thermal level (b012) set to 64 A. Trip time (s) 60 3.0 0 69.8 96 128 (109%) (150%) (200%) 4 Motor current (A) (Ratio to the rated current of the Inverter) Electronic Thermal Characteristics Functions •The frequency characteristics are integrated with the above b012/b212/b312 set values. •A general-purpose motor requires reduced load (current) because the lower the output frequency is, the lower the cooling capability of its self-cooling fan. •The reduced torque characteristics are designed to fit the heat radiation of a general-purpose motor. Reduced Torque Characteristics Multiplied by the time limit characteristics set in b012/b212/b312 for each frequency. (Example) 3G3RX-A2150 (Rated current: 64 A), b012 = 64 (A), Base frequency = 60 Hz, Output frequency = 20 Hz Torque Trip time (s) x1.0 x0.8 x0.6 60 0 0 5 6 16 20 50 60 Inverter output frequency (Hz) 3.0 0 Base frequency 55.8 76.8 102.4 Motor current (A) (87.2%) (120%) (160%) (Ratio to the rated current of the Inverter) Constant Torque Characteristics Do not skip this setting when using a constant torque motor. (Example) 3G3RX-A2150 (Rated current: 64 A), b012 = 64 (A), Output frequency = 2.5 Hz Output current value (A) Torque x1.0 b020 x0.8 b018 x0.6 b016 0 2.5 5 4-47 60 Inverter output frequency (Hz) 0 b015 b017 b019 A004/A204/A304 Max. frequency (Hz) 4-2 Function Mode Free Setting To protect the motor according to load, you can freely set the electronic thermal characteristics. Below is the setting range. Output current value (A) Torque x1.0 b020 b018 x0.8 b016 0 5 40 Inverter output frequency (Hz) 0 b015 b017 b019 A004/A204/A304 Max. frequency (Hz) 4 (Example) Output frequency = b017 Trip time (s) 60 3.0 0 (x) (y) (z) Motor current (A) (Ratio to the rated current of the Inverter) Thermal Warning •This function outputs an alarm signal before electronic thermal overheat protection is activated. The warning level can be set in C061. •Allocate 13 (THM) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). 4-48 Functions (x): (b018/Rated current) × 109% (y): (b018/Rated current) × 150% (z): (b018/Rated current) × 200% 4-2 Function Mode Overload Limit/Overload Warning This function helps prevent an overcurrent trip due to rapid load fluctuation in acceleration or constant speed operation. Parameter No. Function name Data Default setting Unit b021 Overload limit selection 01  b024 Overload limit selection 2 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/ constant speed operation) 02: ON-Cnst (Enabled in constant speed operation) 03: ON-A/C(R) (Enabled in acceleration/ constant speed operation (accelerates during regeneration)) 01  b022 Overload limit level 1.50 × Rated current A b025 Overload limit level 2 1.50 × Rated current A b023 Overload limit parameter 1.00 s 1.00 s 01  Functions 4 0.20 × Rated current to 2.00 × Rated current (0.4 to 55 kW) 0.20 × Rated current to 1.80 × Rated current (75 to 132 kW) 0.10 to 30.00 b026 Overload limit parameter 2 C040 Overload warning signal output mode C041 Overload warning level C111 Overload warning level 2 Related functions 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) 0.0: Does not operate. 0.1 × Rated current to 2.00 × Rated current (0.4 to 55 kW) 0.1 × Rated current to 1.80 × Rated current (75 to 132 kW) (Outputs OL and OL2 signals when reaching the overload warning level.) Rated current A Rated current C001 to C008, C021 to C025, C026 Overload Limit •The Inverter monitors the motor current during acceleration or constant speed operation in order to lower output frequency automatically according to the overload limit parameter once the motor current reaches the overload limit. •This function prevents an overcurrent trip caused by excessive moment of inertia during acceleration, or caused by rapid load fluctuations during constant speed operation. •You can set two types of overload limit functions in b021/b022/b023 and b024/b025/b026. •To switch between b021/b022/b023 and b024/b025/b026, allocate 39 (OLR) to a multi-function input and then turn it on/off. •The overload limit level sets a current value for this function to work. •The overload limit parameter sets a time of deceleration from the maximum frequency to 0 Hz. •When this function operates, the acceleration time becomes longer than the set time. •If "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control method (V/f characteristics) (refer to "Control Method (V/f Characteristics)" (page 421)), and "03" is selected for b021/b024, the frequency increases when a current exceeding the overload limit level flows during regenerative operation. •If overload limit parameter b023/b026 is set too short, an overvoltage trip may occur because of regenerative energy from the motor caused by automatic deceleration of this function even during acceleration. •Make the following adjustments if this function operates before the frequency reaches the target value during acceleration. Increase the acceleration time. (Refer to "Acceleration/Deceleration Time" (page 4-8).) Increase the torque boost. (Refer to "Torque Boost" (page 4-19).) 4-49 4-2 Function Mode Increase the overload limit level (b022/b025). Overload limit level b022/b025 Decelerates according to the set overload limit parameter. Output current Max. frequency A004/A204/A304 Inverter output frequency Target frequency F001 b023/b026 4 Overload Warning Overload limit level b022/b025 Overload warning level C041/C111 Output current OL/OL2 output 4-50 Functions •If the applied load is large, the Inverter can output an overload warning signal before an overload trip occurs. This helps prevent mechanical damage due to an overload in the carrier machine, or an operation line stop due to overload protection of the Inverter. •Allocate "03" (OL) or "26" (OL2) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). (Two types of overload warning signals are available for output.) 4-2 Function Mode Overcurrent Suppression Function •This function suppresses overcurrent caused by a steep current rise in rapid acceleration. •You can set whether to enable or disable this function with b027. Parameter No. Function name b027 Overcurrent suppression function Data Default setting Unit 00  00: ÖFF (Disabled) 01: ON (Enabled) Note: If you use the Inverter with an elevating machine, disable this function. Otherwise, the machine may slide down. Output frequency 4 Desired Functions Actual acceleration after suppression operation Time Output current Suppression level (about 160% of the rating) Time Soft Lock Function •You can set whether to enable or disable the writing of various code data. This helps prevent data rewriting due to erroneous operation. Parameter No. b031 Function name Data Default setting Unit 01  00: Lock (SFT) (Data other than b031 cannot be changed when terminal SFT is ON) 01: Only FQ (SET) (Data other than b031 and specified frequency parameter cannot be changed when terminal SFT is ON) 02: Lock (Data other than b031 cannot be Soft lock selection changed) 03: Only FQ (Data other than b031 and specified frequency parameter cannot be changed) 10: RUN chg mode (Data other than parameters changeable during operation cannot be changed) Related functions C001 to C008, SFT input •Select the soft lock setting and performing method from the above table. •To use a multi-function input terminal, allocate 15 (SFT) to any of multi-function inputs 1 to 8 (C001 to C008). 4-51 4-2 Function Mode RUN Time/Power ON Time Exceeded •If the total RUN time of the Inverter exceeds the time set in ON time setting b034, a RUN/Power ON 'time exceeded' (RNT/ONT) signal is output. Parameter No. Function name b034 RUN time/Power ON time setting Data Default setting Unit 0  0 to 65535 Related functions C021 to C025, C026, d016, d017 RUN Time Exceeded (RNT) •Allocate 11 (RNT) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). •Set a time in RUN time/Power ON time setting b034. •Allocate 12 (ONT) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). •Set a time in RUN time/Power ON time setting b034. Rotation Direction Limit Selection •Limits motor rotation directions. •Enabled in either "control circuit terminal block" or "Digital Operator" control mode. Parameter No. Function name b035 Rotation direction limit selection Data 00: FREE (Forward and Reverse are enabled) 01: FWD (Only Forward is enabled) 02: REV (Only Reverse is enabled) Default setting Unit 00  4-52 Functions Power ON Time Exceeded (ONT) 4 4-2 Function Mode Reduced Voltage Startup Selection •Slowly increases voltage during motor startup. •To increase torque during startup, reduce the set value of reduced voltage startup selection b036. Note that if the value is too small, the motor starts in full-voltage starting mode, possibly resulting in an overcurrent trip. Parameter No. Function name Data Reduced voltage startup selection b036 4 Default setting Unit 6  00: Reduced voltage startup disabled 01 to 255: 01: Short (approx. 6 ms) 255: Long (approx. 1.53 s) Functions Related functions b082 FW Starting frequency b082 Output frequency Output voltage 00 01 06 Display Selection •You can change the items to be displayed on the Digital Operator. Parameter No. b037 Function name Data Default setting Unit Display selection 00: All (Complete display) 01: Utilized (Individual display of functions) 02: User (User setting) 03: Only FQ (Data comparison display) 04: Basic (Basic display) 00  no  _ _no: No allocation U001 to U012 4-53 User selection d001 to P196: Select the code you want to display. (Among all codes) 4-2 Function Mode Individual Display of Functions •If a specific function is not selected, its relevant parameter is not displayed. •For details on the display requirements, refer to the following table. No. Display requirements Parameters displayed when the requirements are met 1 A001 = 01 A005, A006, A011 to A016, A101, A102 A111 to A114, C081 to C083, C121 to C123 2 A001 = 10 A141 to A143 3 A002 = 01, 03, 04, 05 b087 4 A017 = 01 d025 to d027, P100 to P131 (Note that P100 to P131 cannot be used.) 5 A041 = 01 A046, A047 6 A044 = 00, 01 A041, A042, A043 7 A044 = 03, 04, 05 H002, H005, H050 8 A044 = 04 H060, H061 9 A044 = 03, 04, 05, and H002 = 00 H020 to H024 10 A044 = 03, 04, 05, and H002 = 01, 02 H030 to H034 11 Either of A044 or A244 = 03, 04, 05 d008 to d010, d012, b040 to b046, H001, H070 to H073 12 Either of A044 or A244 = 02 b100 to b113 13 A051 = 01, 02 A052, A056 to A058 14 A051 = 01, 02 A053 to A055, A059 15 A071 = 01, 02 d004, A005, A006, A011 to A016, A072 to A078 A101, A102, A111 to A114, C044, C052, C053, C081 to C083, C121 to C123 16 A076 = 10 A141 to A143 17 A094 = 01, 02 A095, A096 18 A097 = 01, 02, 03, 04 A131 19 A097 = 01, 02, 03, 04 A132 20 Any of b012, b212, and b312 = 02 b015 to b020 21 b021 = 01, 02, 03 b022, b023 22 b024 = 01, 02, 03 b025, b026 23 b050 = 01 b051 to b054 24 b095 = 01, 02 b090, b096 25 b098 = 01, 02 b099, C085 26 b120 = 01 b121 to b127 27 Any of C001 to C008 = 05, and A019 = 00 A028 to A035 28 Any of C001 to C008 = 06 A038, A039 29 Any of C001 to C008 = 07 A053 to A055, A059 30 Any of C001 to C008 = 08 F202, F203, A203, A204, A220, A244, A246, A247, A261, A262, A292, A293, A294, b212, b213, H203, H204, H206 31 Any of C001 to C008 = 08, and A041 = 01 A246, A247 32 Any of C001 to C008 = 08, and A244 = 00, 01 A241, A242, A243 4 Functions 4-54 4-2 Function Mode Functions 4 No. Display requirements Parameters displayed when the requirements are met 33 Any of C001 to C008 = 08, and A244 = 03, 04 H202, H205, H250, H251, H252 34 Any of C001 to C008 = 08, and A244 = 04 H260, H261 35 Any of C001 to C008 = 08, A244 = 03, 04, and H202 = 00 H220 to H224 36 Any of C001 to C008 = 08, A244 = 03, 04, and H202 = 01, 02 H230 to H234 37 Any of C001 to C008 = 08, and A094 = 01, 02 A295, A296 38 Any of C001 to C008 = 11 b088 39 Any of C001 to C008 = 17 F302, F303, A303, A304, A320, A342, A343, A392, A393, b312, b313, H306 40 Any of C001 to C008 = 18 C102 41 Any of C001 to C008 = 27, 28, 29 C101 42 Any of C021 to C026 = 03 C040, C041 43 Any of C021 to C026 = 26 C040, C111 44 Any of C021 to C026 = 02, 06 C042, C043 45 Any of C021 to C026 = 07 C055 to C058 46 Any of C021 to C026 = 21 C063 47 Any of C021 to C026 = 24, 25 C045, C046 48 Any of C021 to C026 = 33 C142 to C144 49 Any of C021 to C026 = 34 C145 to C147 50 Any of C021 to C026 = 35 C148 to C150 51 Any of C021 to C026 = 36 C151 to C153 52 Any of C021 to C026 = 37 C154 to C156 53 Any of C021 to C026 = 38 C157 to C159 54 Any of C021 to C026 = 42 C064 User Setting •Displays only the parameters optionally set in U001 to U012. •In addition to U001 to U012, d001, F001 and b037 are displayed. Data Comparison Display •Displays only the parameters changed from the factory default. Note that analog input adjustments C081, C082, C083, C121, C122, and C123, and thermistor adjustment C085 are not displayed. •All monitors (d***) and F001 are displayed. 4-55 4-2 Function Mode Basic Display •Displays basic parameters. •Below are the parameters displayed when this function is enabled. No. 1 Data Function name d001 to d104 Monitor display No. Data Function name 16 A045 Output voltage gain 2 F001 Output frequency setting/monitor 17 A085 RUN mode selection 3 F002 Acceleration time 1 18 b001 Retry selection 4 F003 Deceleration time 1 19 b002 Allowable momentary power interruption time 5 F004 Operator rotation direction selection 20 b008 Trip retry selection 6 A001 Frequency reference selection 21 b011 Trip retry wait time 7 A002 RUN command selection 22 b037 Display selection 8 A003 Base frequency 23 b083 Carrier frequency 9 A004 Maximum frequency 24 b084 Initialization selection 10 A005 O/OI selection 25 b130 Overvoltage protection function selection during deceleration 11 A020 Multi-step speed reference 0 26 b131 Overvoltage protection level during deceleration 12 A021 Multi-step speed reference 1 27 C021 Multi-function output terminal 11 selection 13 A022 Multi-step speed reference 2 28 C022 Multi-function output terminal 12 selection 14 A023 Multi-step speed reference 3 29 C036 Relay output (AL2, AL1) contact 15 A044 V/f characteristics selection U001 to U012 Initial Screen Selection (Initial Screen at Power-ON) You can select the Digital Operator screen to be displayed at power-on among the following items. (By factory default, "01" (d001) is selected.) Parameter No. Function name b038 Initial screen selection Data 000 to 202 Default setting Unit 001  Note: With "00" (screen on which the Enter key was last pressed) selected, if the last screen is other than d*** or F***, the entrance (*---) of each group is displayed. (Example) When the power is turned off and then on after a change in the A020 setting, "A---" is displayed. 4-56 Functions Related functions 4 4-2 Function Mode User Parameter Automatic Setting Function •When user parameter automatic setting function b039 is set to "01" (enabled), the parameters subjected to a data change are automatically stored in sequence (from U001 to U012). This data can be used as changed data. •The screen information is stored when the Enter key is pressed. The monitor screens (d***) are also stored in the same manner. •U001 is the most recent parameter, and U012 is the oldest. •The same parameter cannot be stored. If the number of parameters stored exceeds 12, the oldest data (U012) is erased. Parameter No. Function name b039 User parameter automatic setting function selection 4 Data Unit 00  00: OFF (Disabled) 01: ON (Enabled) Related functions Functions Default setting U001 to U012 Torque Limit Function •This function limits motor output torque when "03" (sensorless vector control), "04" (0-Hz sensorless vector control), or "05" (sensor vector control) is selected in control method A044/A244. Parameter No. Function name Data Default setting Unit A044/A244 V/f characteristics selection 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00  00: 4-quadrant (Four-quadrant separate setting) 01: TRQ input (Terminal switch) 02: [O] input (Analog input) 03: Option 1 04: Option 2 00  b040 Torque limit selection b041 Torque limit 1 (Four-quadrant mode forward power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Forward power running under four-quadrant separate setting 150 % b042 Torque limit 2 (Four-quadrant mode reverse regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Reverse regeneration under four-quadrant separate setting 150 % b043 Torque limit 3 (Four-quadrant mode reverse power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Reverse power running under four-quadrant separate setting 150 % b044 Torque limit 4 (Four-quadrant mode forward regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Forward regeneration under four-quadrant separate setting 150 % C001 to C008 Multi-function inputs 1 to 8 selection 40: TL (Torque limit enabled) 41: TRQ1 (Torque limit switching 1) 42: TRQ2 (Torque limit switching 2)   C021 to C025 Multi-function output terminal 11 to 15 selection 10: TRQ (Torque limit)   Related functions 4-57 A044, A244, C001 to C008 4-2 Function Mode •You can select any of the following four torque limit functions from torque limit selection b040. Sets torque limits 1 to 4 (b041 to b044) for four quadrants (forward power running, regeneration, reverse power running, and regeneration). Switches over torque limits 1 to 4 (b041 to b044), depending on combinations of torque limit switchings 1 and 2 (TRQ1 and TRQ2) allocated to multi-function inputs. Selected torque limit values are enabled for all operation modes. Sets a torque limit value depending on the voltage applied to terminal O2 on the control terminal block. 0 to 10 V correspond to torque limit values of 0% to 200%. Selected torque limit values are enabled for all operation modes. Enabled when an optional 3G3AX-DI01 board is used. For details, refer to the optional board instruction manual. Torque Regeneration b042 Power running b041 Power running b043 Regeneration b044 Reverse (RV) Forward (FW) •The following figure shows torque limits 1 to 4 with "01" (terminal switching) selected in torque limit selection b040. They can be switched with torque limit switchings 1 and 2 allocated to multifunction inputs. (Example) When torque limit switching 1 (41) and torque limit switching 2 (42) are allocated to multi-function input terminals 7 and 8, respectively Multi-function input terminals (41) (42) 7 8 OFF ON OFF ON OFF OFF ON ON P24 b041 b042 b043 b044 •To use the torque limit function in a low speed range, also use the overload limit function. 4-58 Functions •If the torque limit enable function (TL) is set for a multi-function input, the torque limit function set in b040 is enabled only when TL is turned on. When TL is off, the torque limit setting is disabled, and the maximum value is defined as the torque limit value. Unless the torque limit enable function (TL) is set for a multi-function input, the torque limit function set in torque limit selection b040 is always enabled. •With this function, the torque limit value is set with the Inverter's maximum output current as 200%. This means output torque varies depending on the combination of motors. Note that the torque limit value is not the absolute one. •When the torque limit signal is selected in the multi-function output selection, the torque limit signal is turned on when the above torque limit function is activated. •The following figure shows torque limits 1 to 4 with "00" (four-quadrant separate setting) selected in torque limit selection b040. 4 4-2 Function Mode Reverse Rotation Prevention Function •This function is enabled when "03" (sensorless vector control), "04" (0-Hz sensorless vector control), or "05" (sensor vector control) is selected in control method A044/A244. •Because of the Inverter's control characteristics, the Inverter may output a rotation signal in the direction opposite to that of the RUN command (e.g. in a low-speed range). If the motor's reverse rotation may cause a problem (e.g. damage to the machine driven by the motor), set reverse rotation prevention selection b046 to "enabled". Parameter No. Function name Data Default setting Unit A044/A244 V/f characteristics selection 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00  b046 Reverse rotation prevention selection 00: OFF (Disabled) 01: ON (Enabled) 00  Functions 4 Torque LADSTOP Function •If "03" (sensorless vector control), "04" (0-Hz sensorless vector control), or "05" (sensor vector control) is selected in control method A004/A244, this function temporarily stops the frequency deceleration function (LAD) when the torque limit function is activated. Parameter No. Function name A044/A244 V/f characteristics selection Data Default setting Unit 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00  00: 4-quadrant (Four-quadrant separate setting) 01: TRQ input (Terminal switch) 02: [O] input (Analog input) 03: Option 1 04: Option 2 00  150 % 00: OFF (Disabled) 01: ON (Enabled) 00  40: TL (Torque limit enabled) 41: TRQ1 (Torque limit switching 1) 42: TRQ2 (Torque limit switching 2)   b040 Torque limit selection b041 Torque limit 1 (Four-quadrant mode forward power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Forward power running under four-quadrant separate setting b042 Torque limit 2 (Four-quadrant mode reverse regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Reverse regeneration under four-quadrant separate setting b043 Torque limit 3 (Four-quadrant mode reverse power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Reverse power running under four-quadrant separate setting b044 Torque limit 4 (Four-quadrant mode forward regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) no (Torque limit disabled) Forward regeneration under four-quadrant separate setting b045 Torque LADSTOP selection C001 to C008 Multi-function inputs 1 to 8 selection 4-59 4-2 Function Mode Dual Rating Selection •Ratings of the inverter are switched to Heavy Duty (CT) and Normal Duty (VT) and it enables it. The ratings current value changes by switching Heavy Duty (CT) and Normal Duty (VT). •The method of switching a Heavy Duty and a Normal Duty is done by Heavy Duty/Normal Duty selection (b049) in the operator. Parameter No. Function name b049 Dual Rate Selection Data Default setting Unit 00  00: CT (Constant torque) 01: VT (Variable torque) •In the Normal Duty (VT), there is the item which is not displayed in the parameter of the operator. Parameter No. Function name Function code Function name 4 Real frequency monitor P024 Position bias amount d009 Torque reference monitor P025 Secondary resistance compensation enable/ disable selection d010 Torque bias monitor P026 Overspeed error detection level d029 Positioning command monitor P027 Speed deviation error detection level d030 Current position monitor P028 Motor gear ratio numerator b120 Brake control enable P029 Motor gear ratio denominator b121 Brake wait time for release P032 Orientation stop position input type b122 Brake wait time for acceleration P033 Torque reference input selection b123 Brake wait time fot stopping P034 Torque reference setting b124 Brake wait time for confirmation P035 Polarity selection at torque reference via O2 b125 Brake release frequency P036 Torque bias mode b126 Brake release current P037 Torque bias value b127 Brake input frequency P038 Torque bias polarity selection H060 Limit at 0 Hz P039 Speed limit value in torque control (forward) H260 *2nd limit at 0 Hz P040 Speed limit value in torque control (reverse) H061 Boost amount at SLV startup, 0 Hz P060 Multi-step position command 0 H261 *2nd boost amount at SLV startup, 0 Hz P061 Multi-step position command 1 P011 Encoder pulses P062 Multi-step position command 2 P012 V2 control mode selection P063 Multi-step position command 3 P013 Pulse train mode selection P064 Multi-step position command 4 P014 Orientation stop position P065 Multi-step position command 5 P015 Orientation speed setting P066 Multi-step position command 6 P016 Orientation direction setting P067 Multi-step position command 7 P017 Position ready range setting P068 Zero return mode P018 Position ready delay time setting P069 Zero return direction selection P019 Electronic gear setting position selection P070 Low-speed return frequency P020 Electronic gear ratio numerator P071 High-speed zero return frequency P021 Electronic gear ratio denominator P072 Position range specification (forward) P022 Position control feedforward gain P073 Position range specification (reverse) P023 Position loop gain P074 Teaching selection Functions d008 4-60 4-2 Function Mode •In the Normal Duty (VT), there is an item limited in the parameter of the operator by the setting range. Function code A044/A244 Functions 4 Function name 1st/2nd V/f characteristics selection A054 DC injection braking power A057 Startup DC injection braking power A059 DC injection braking carrier frequency A085 RUN mode selection b022 Overload limit level b025 Overload limit level 2 b028 Active Frequency Matching restart level b041 Torque limit 1 (Four-quadrant mode forward power running) b042 Torque limit 2 (Four-quadrant mode reverse regeneration) b043 Torque limit 3 (Four-quadrant mode reverse power running) b044 Torque limit 4 (Four-quadrant mode forward regeneration) b083 Carrier frequency C030 Digital current monitor reference value C039 Light load detection level C041 Overload warning level C055 Overtorque level (Forward power running) C056 Overtorque level (Reverse regeneration) C057 Overtorque level (Reverse power running) C058 Overtorque level (Forward regeneration) C111 Overload warning level 2 •In the Normal Duty (VT), these terminals are not available. •Intelligent input terminal that cannot set Normal Duty. Code 4-61 Intelligent input terminal name 44: BOK Brake confirmation 45: ORT Orientation 47: PCLR Position deviation error 48: STAT Pulse train position command input permission 52: ATR Torque command input permission 54: SON Servo ON 55: FOC Preliminary excitation 66: CP1 Position command selection 1 67: CP2 Position command selection 2 68: CP3 Position command selection 3 69: ORL Zero return limit signal 70: ORG Zero return startup signal 71: FOT Forward driving stop 72: ROT Reverse driving stop 73: SPD Speed/Position switching 4-2 Function Mode •Intelligent output terminal that cannot set Normal Duty. Code Intelligent output terminal name 19: BRK Brake release 20: BER Brake error 22: DSE Excessive speed deviation 23: POK Position ready •When the parameter becomes outside a set range when changing to Heavy Duty -> Normal Duty, it changes to an initial value. •An initial value of the following parameters is different in Heavy Duty ratings and Normal Duty ratings. When Heavy Duty/Normal Duty is changed with b049, items other than H003/H203 are changed to an initial value. Name Func. code HD V/f characteristi cs selection 00: VC (Const. torque) 01: VP (Reduced torque) A044 02: Free V/F A244 03: SLV (sensorless vector) A344* 04: 0SLV (0-Hz sensorless) 05: V2 (Sensor vector) DC injection braking power A054 Startup DC injection braking power ND Initial data Range Initial data 00: Const. torque 00: VC (Const. torque) 01: VP (Reduced torque) 02: Free V/F 00: Const. torque 0 to 100 (%) 0.4 to 55kW 0 to 80 (%) 75 to 132kW 50% 0.4-55kW 40% 75-132kW 0 to 70 (%) 0.4 to 55kW 0 to 50 (%) 75 to 132kW 50% 0.4-55kW 40% 75-132kW A057 0 to 100 (%) 0.4 to 55kW 0 to 80 (%) 75 to 132kW 0 (%) 0 to 70 (%) 0.4 to 55kW 0 to 50 (%) 75 to 132kW 0 (%) DC injection braking carrier frequency A059 0.5 to 15.0 (kHz) 0.4-55kW 0.5 to 10.0 (kHz) 75-132kW 5.0 (kHz) 0.4-55kW 0.5 to 12.0 (kHz) 0.4-55kW 3.0 (kHz) 0.5 to 8.0 (kHz) 75-132kW Electronic thermal level b012 (0.20 to 1.00) x Rated current Rated current (A) (0.20 to 1.00) x Rated current Rated current (A) Overload limit level b022/ b222 Overload limit level 2 1.50 x Rated current (A) (0.20 to 1.50) x Rated current (A) 1.20 x Rated current (A) b025 (0.20 to 2.00) x Rated current (A) 0.4-55kW (0.20 to 1.80) x Rated current (A) 75-132kW Carrier frequency b083 0.5 to 15.0 (kHz) 0.4-55kW 0.5 to 10.0 (kHz) 75-132kW 5.0 (kHz) 0.4-55 kW 0.5 to 10.0 (kHz) 0.4-55kW 3.0 (kHz) 0.5 to 8.0 (kHz) 75-132kW Motor capacity selection H003/ 0.2 to 160 (kW) H203 Depends on type 0.4 to 160 (kW) One size up than HD * For the A344 parameter there are only two options available: 00 (VC) and 01 (VP). 4-62 Functions Range 4 4-2 Function Mode Momentary Power Interruption Non-stop Function •After the power is shut off during operation, this function decelerates the Inverter to a stop while keeping the voltage below the overvoltage level. •You can select from three modes in momentary power interruption non-stop selection b050. Parameter No. Function name Data Default setting Unit b050 Selection of non-stop function at momentary power interruption 00: OFF (Disabled) 01: V-Cnst (STOP) (Enabled (deceleration stop)) 02: NS1 (Enabled (without recovery)*5 03: NS2 (Enabled (with recovery)*5 00  b051 Starting voltage of non-stop function at momentary power interruption *4 0.0 to 1000.0 220/440 V b052 Stop deceleration level of non-stop function at momentary power interruption *1 *4 0.0 to 1000.0 360/720 V b053 Deceleration time of nonstop function at momentary power interruption *3 0.01 to 3600.00 1.00 s b054 Deceleration starting width of non-stop function at momentary power interruption *3 0.00 to 10.00 0.00 Hz b055 Proportional gain setting of non-stop function at momentary power interruption 0.00 to 2.55: Proportional gain for DC voltage constant control (b050 = 02, 03 only) 0.20  b056 Integral time setting of nonstop function at momentary power interruption 0.000 to 65.535: Integral time for DC voltage constant control (b050 = 02, 03 only) 0.100 s Functions 4 4-63 4-2 Function Mode Momentary Power Interruption Non-stop Deceleration Stop (b050 = 01) •After the power is shut off during operation, this function decelerates the Inverter to a stop while keeping the voltage below the momentary power interruption non-stop deceleration level (b052). •To use this function, remove the J51 connector cable connected between terminals Ro and To, and connect the cable from main terminal P to Ro, and from N to To. The cable size should be 0.75 mm2 or larger. •If the power is shut off during operation and the voltage falls below the momentary power interruption non-stop function starting voltage (b051), the frequency deceleration width decreases at the momentary power interruption non-stop deceleration starting width (b054), and then the Inverter decelerates for the momentary power interruption non-stop deceleration time (b053). •If an overvoltage condition (momentary power interruption non-stop deceleration level b052 or higher) occurs because of regeneration during deceleration, the Inverter is kept in the LAD STOP status until the overvoltage condition is reset. Main circuit P-N voltage VPN (V) b052 b051 Undervoltage level Time (s) Output frequency (Hz) b054 b053 Time (s) 4-64 Functions *1. When the momentary power interruption non-stop deceleration level (b052) < the momentary power interruption non-stop function starting voltage (b051), the Inverter performs this function by increasing the momentary power interruption non-stop deceleration level (b052) to the momentary power interruption non-stop function starting voltage (b051). (The set value will not be changed.) If b052 is lower than the incoming voltage or equivalent (DC voltage or equivalent after rectification [incoming voltage × 2]), the Inverter is brought into the LAD STOP status at power recovery during execution of this function, disabling deceleration. (The Inverter will accept neither a STOP command nor frequency reference change until operation is complete.) Make sure that the b052 setting is higer than the normal incoming voltage or equivalent. *2. This function is not reset before the operation is complete and stopped. To run the Inverter after power recovery during this function, input the RUN command following the STOP command (RUN command OFF) after a stop condition. *3. If the momentary power interruption non-stop deceleration starting width (b054) is too large, an overcurrent trip occurs because of rapid deceleration. If b054 is too small, or if the momentary power interruption non-stop deceleration time (b053) is too long, an undervoltage trip occurs because of insufficient regeneration power. 4 4-2 Function Mode Momentary Power Interruption Non-stop DC Voltage Constant Control (b050 = 02: without recovery, b050 = 03: with recovery) •If a momentary power interruption or main circuit DC voltage drop occurs during operation, the Inverter decelerates while keeping the main circuit DC voltage at the value set in momentary power interruption non-stop target voltage (OV-LADSTOP level) b052. •This function is started when the following conditions are all satisfied: • b050 = "02" or "03" • The Inverter is running. (This function is disabled during trip/undervoltage/stop.) • The control power supply is momentarily interrupted, or the main circuit DC voltage falls below the momentary power interruption non-stop function starting voltage (b051) •This function is enabled when the above starting conditions are satisfied, even if the J51 connector cable is disconnected from terminals Ro and To and is connected from main terminal P to Ro and from N and To, or even if the control power supply is separated from the main circuit power supply. •If the time of momentary power interruption is short, the Inverter can continue to run without shutting off the output. However, if undervoltage occurs because of momentary power interruption, the Inverter immediately shuts off the output, and stops operating this function. The subsequent power recovery depends on the setting of retry selection b001. •With b050 = 03, the Inverter can be restored to normal operation, if a momentary power interruption occurs and incoming voltage recovers before the output is shut off. Note that the Inverter may decelerate to a stop, depending on the b051 setting. Below are the details. Functions 4 b050 b051 Operation b052 > Main circuit DC voltage at power recovery Deceleration stop (DC voltage constant control) (example 1) b052 < Main circuit DC voltage at power recovery Deceleration stop (normal operation) (example 2) b052 > Main circuit DC voltage at power recovery Deceleration stop (DC voltage constant control) (example 1) b052 < Main circuit DC voltage at power recovery Operation (normal operation) (example 2) 02 (without recovery) 03 (with recovery) •If operation of this function results in deceleration stop, the Inverter is forced to stop, even if the FW command is ON. To restart the Inverter, make sure that the incoming voltage has recovered, and input the FW command again. *4. Make sure that the b051/b052 set values are larger than the undervoltage level (200-V class: 210 V, 400-V class: 410 V). If undervoltage occurs, this function is disabled. Make sure that b051 is smaller than b052. If the proportional gain setting (b055) is excessively increased when the difference between b051 and b052 is large, the Inverter may accelerate immediately after this function starts, resulting in overcurrent. *5. When b050 = 02, 03, PI control works to keep the internal DC voltage constant. • Though quicker response is expected with a larger proportional gain (b055), control tends to be divergent and may easily lead to a trip. • Response also becomes quicker with a shorter integral time (b056), but if too short, the same situation may occur. • If the proportional gain (b055) is too small, the voltage drops immediately after this function starts, resulting in an undervoltage trip. 4-65 4-2 Function Mode (Example 1) (Example 2) Main circuit P-N voltage Vpn (V) Main circuit P-N voltage Vpn (V) Main circuit DC voltage at power recovery b052 Power recovery Main circuit DC voltage b052 b051 b051 DC voltage kept constant DC voltage kept constant Time Output frequency (Hz) Output frequency (Hz) 4 b050 = 03 (Operation) b050 = 02 (Deceleration stop) Time Power recovery Time Power recovery Note: The main circuit DC voltage level, while the function is running, may fall below the b052 set value depending on the proportional gain and integral time settings. Window Comparator (Disconnection Detection ODc/OIDc/O2Dc) •The Inverter activates the window comparator output when the O/OI/O2 analog input value is within the upper and lower limit levels of the window comparator. This function allows you to monitor analog input based on the desired level (e.g. to detect a disconnection). Parameter No. Function name Data C021 to C025 Multi-function output terminals 11 to 15 selection C026 Relay output (AL2, AL1) function selection 27: ODc (analog O disconnection detection) 28: OIDc (analog OI disconnection detection) 29: O2Dc (analog O2 disconnection detection) 54: WCO (window comparator O) 55: WCOI (window comparator OI) 56: WCO2 (window comparator O2) b063 (OI) Window comparator O/OI/O2 upper limit level Set an upper limit level. Setting range: -100 to 100 Lower limit: Lower limit level + Hysteresis width × 2 b061 (O) b064 (OI) Window comparator O/OI/O2 lower limit level b067 (O2) Unit   05 Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 b060 (O) b066 (O2) Default setting 100 % Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 0 % Set a lower limit level. Setting range: -100 to 100 Upper limit: Upper limit level - Hysteresis width × 2 -100 % 4-66 Functions b050 = 02, 03 (Deceleration stop) Time 4-2 Function Mode Parameter No. b062 (O) Function name Set a hysteresis width for the upper and lower limit levels. Window comparator Setting range: 0 to 10 O/OI/O2 hysteresis width Upper limit: (Upper limit level - Lower limit level) × 2 b065 (OI) b068 (O2) b070 (O) b071 (OI) Analog operation level at O/OI/O2 disconnection b072 (O2) Functions 4 Data Default setting Unit 0 % no  0 to 100/no (ignored): Set an analog input application value used for WCO/WCOI/ WCO2 (ODc/OIDc/O2Dc) output. -100 to 100/no (ignored): Set an analog input application value used for WCO/WCOI/ WCO2 (ODc/OIDc/O2Dc) output. •You can set hysteresis widths for the window comparator upper and lower limit levels. •You can set limit levels and a hysteresis width individually for O, OI, and O2 inputs. •For the WCO/WCOI/WCO2 output, you can fix the analog input application value to the desired value. Set values in O/OI/O2 disconnection operation levels b070/b071/b072. If "no" is set, the analog input value is directly reflected. •ODc/OIDc/O2Dc outputs are the same as WCO/WCOI/WCO2, respectively. O/OI/O2 inputs Max (100%) Hysteresis width (b062, b065, b068) Window comparator upper limit level (b061/b064/b067) Analog application value Analog operating level on disconnection (b070/b071/b072) Min (O/OI: 0%) (O2 : -100%) WCO/WCOI/WCO2 ODc/OIDc/O2Dc 4-67 Analog input value Window comparator lower limit level (b060/b063/b066) 4-2 Function Mode Starting Frequency •Set the frequency for starting Inverter output when the RUN signal is turned on. Parameter No. Function name b082 Starting frequency Data Default setting Unit 0.50 Hz 0.10 to 9.99 •Use mainly to adjust the starting torque. •With starting frequency b082 set high, the starting current increases, possibly causing the current to exceed the overload limit and overcurrent protection to work to trip the Inverter. •If "04" (OSLV: 0-Hz sensorless vector control) or "05" (V2: sensor vector control) is selected in control method selection A044, this function is disabled. 4 FW Functions b082 Output frequency Output voltage Carrier Frequency •You can change the PWM waveform carrier frequency output from the Inverter. Parameter No. Function name b083 Carrier frequency Data (HD) Data (ND) Default setting 0.5 to 15.0 (0.4 to 55 kW) 0.5 to 12.0 (0.4 to 55 kW) 5.0 0.5 to 10.0 (75 to 132 kW) 0.5 to 8.0 (75 to 132 kW) 3.0 Unit kHz •With the carrier frequency set high, you can reduce metallic noise from the motor. However, this increases noise or leakage current from the Inverter. •Helps avoid mechanical or motor resonance. •The maximum carrier frequency varies depending on the capacity. To raise the carrier frequency (fc), derate the output current as shown in the following table. •Set a derating output current value as electronic thermal level. (If the existing electronic thermal value is lower than the derating value, the above setting is not required.) •To raise the carrier frequency, reduce the output current (or derate the rated current) as shown in the graph below. Voltage 200-V class Derating at fc = 12 kHz (ND) 400-V class Derating at fc = 15 kHz (HD) Max. fc (kHz) Derating at fc = 12 kHz (8kHz for 75 to 132 kW) (ND) Derating at fc = 15 kHz (10 kHz for 75 to 132 kW) (HD) Capacity Max. fc (kHz) 0.4 kW 15 100% 100% 15 100% 100% 0.75 kW 15 100% 100% 15 100% 100% 1.5 kW 15 100% 100% 15 100% 100% 2.2 kW 15 100% 100% 15 100% 100% 3.7 kW 15 90% 100% 15 90% 100% 5.5 kW 15 100% 100% 15 100% 100% 4-68 4-2 Function Mode Voltage Derating at fc = 12 kHz (ND) 400-V class Derating at fc = 15 kHz (HD) Max. fc (kHz) Derating at fc = 12 kHz (8kHz for 75 to 132 kW) (ND) Derating at fc = 15 kHz (10 kHz for 75 to 132 kW) (HD) Capacity Max. fc (kHz) 7.5 kW 15 100% 100% 15 100% 100% 11 kW 12 90% 90% 15 100% 100% 15 kW 12 90% 95% 14 100% 95% 18.5 kW 10 90% 90% 10 95% 90% 22 kW 7 90% 70% 6 90% 75% 30 kW 5 80% 80% 10 80% 75% 37 kW 10 75% 75% 8 90% 80% 45 kW 5 90% 70% 9 80% 75% 55 kW 5 90% 70% 6 75% 60% 75 kW    6 90% 85% 90 kW    4 80% 75% 110 kW    6 80% 70% 132 kW    3 70% 60% 4 Normal duty 200-V class 400-V class 100 95 90 55kW 85 80 75 70 65 60 55 6 4 0.5 2 15kW ,45kW 30kW 37kW 8 110kW 75kW 0.4-2.2kW , 5.5kW , 7.5kW 10 Output current derating Output current derating 3.7kW , 18.5kW 11kW 22kW 12 100 95 90 85 80 75 70 65 60 55 0.5 2 37kW 4.0kW 0.4-2.2kW , 5.5-15kW 18.5kW 22kW 30kW 45kW 90kW 55kW 132kW 4 8 6 10 12 Carrier frequency (kHz) Carrier frequency (kHz) Heavy duty 200-V class 100 95 90 85 80 75 70 65 60 55 0.5 2 22 kW 18.5 kW 400-V class 15 kW 45, 55 kW 30 kW 37 kW 4 6 8 10 12 Carrier frequency (kHz) 90 kW 75 kW 45 kW 30 kW 15 kW 11 kW 14 15 Output current derating Output current derating Functions 200-V class 100 95 90 85 80 75 70 65 60 55 0.5 2 18.5 kW 37 kW 132 kW 22 kW 55 kW 110 kW 4 6 8 10 12 14 15 Carrier frequency (kHz) •If the above maximum rated carrier frequency and the derating value at 15 kHz are exceeded, the Inverter may be damaged and/or the service life may be shortened. 4-69 4-2 Function Mode Parameter Initialization •You can initialize the rewritten set values and reset to the factory default. •You can clear trip data. •You cannot clear the P100 to P131 set values, RUN time, or power ON time. Parameter No. b084 Function name Initialization selection Initialization parameter selection b180 Initialize trigger Default setting Unit 00: no (Clears the trip monitor) 01: Trip data (Initializes data) 02: Parameters (Clears the trip monitor and initializes data) 03: Trip+Param (Clears the trip monitor and parameters) 04: Trp+Prm+EzSQ (Clears the trip monitor, parameters and Drive program) 00  01 *Do not change. 01  00: No action 01: Initialize 00  4 STOP Key Selection •When "control circuit terminal block" is selected for the RUN command, you can set whether the STOP/RESET key on the Digital Operator is used to activate the STOP command and trip reset operation. •This setting is enabled when any item other than "02" (Digital Operator) is selected in RUN command selection A002. (Refer to "RUN Command Selection" (page 4-11).) If "02" (Digital Operator) is selected in A002, the STOP command and trip reset operation are enabled regardless of this setting. Parameter No. b087 Function name STOP key selection Data 00: ON (Enabled) 01: OFF (Disabled) 02: Only RESET (Disabled only during stop) Default setting Unit 00  Data STOP command via the STOP/RESET key on the Digital Operator Trip reset operation via the STOP/RESET key on the Digital Operator 00 Enabled Enabled 01 Disabled Disabled 02 Disabled Enabled Stop Selection •You can set whether the Inverter decelerates to a stop for the set deceleration time or goes into free-run status, when the STOP command is input from the Digital Operator or the control circuit terminal block. 4-70 Functions b085 Data 4-2 Function Mode •If the RUN command is input again during free running, the Inverter restarts according to free-run stop selection b088. (Refer to "Free-run Stop Selection" (page 4-71).) Parameter No. Function name b091 Stop selection Functions 4 Data b088 Free-run stop selection b003 Retry wait time b007 Frequency matching lower limit frequency setting Default setting Unit 00: Decel-Stop (Deceleration  Stop) 01: Free-RUN (Free-run stop) 00  00: 0-Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart) 00  0.3 to 100.0 1.0 s 0.00 to 400.00 0.00 Hz Related functions F003, F203, F303 Free-run Stop Selection •Activating the free-run stop (FRS) function shuts off the Inverter output, letting the motor go into free-run status. Parameter No. Function name Data Default setting Unit b088 Free-run stop selection 00: 0-Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart) 00  b003 Retry wait time 0.3 to 100.0: Time before restart 1.0 s b007 Frequency matching lower limit frequency setting 0.00 to 400.00: Set a frequency matching level. 0.00 Hz b028 Active Frequency Matching restart level Rated current A b029 Active Frequency Matching restart parameter 0.50 s b030 Starting frequency at Active Frequency Matching restart 00  0.20 × Rated current to 2.00 × Rated current (0.4 to 55 kW) 0.20 × Rated current to 1.80 × Rated current (75 to 132 kW) 0.10 to 30.00 00: Off FQ (Frequency at interruption) 01: Max.FQ (Max. frequency) 02: Set FQ (Set frequency) •Helps stop the motor using a mechanical brake such as an electromagnetic one. Note that an overcurrent trip may occur if the mechanical brake forces the motor to stop during Inverter output. •Allocate 11 (FRS) to any of multi-function inputs 1 to 8 (C001 to C008). •Performs a free-run stop (FRS) while the FRS terminal is turned on. When the FRS terminal is turned off, the motor restarts after the retry wait time (b003) elapses. However, if RUN command selection A002 is set to "02" (Digital Operator), the Inverter does not restart. To restart the Inverter, input the RUN command. •You can select as the Inverter output mode for restart a 0-Hz start, frequency matching start or Active Frequency Matching restart at free-run stop selection b088. (Examples 1, 2, 3) •If you set frequency matching lower limit frequency setting b007, the Inverter restarts at 0 Hz, when the Inverter detects a frequency equal to or lower than this setting during frequency matching start. 4-71 4-2 Function Mode •The setting of this function is applied to the FRS terminal, and also to the status when the Inverter is reset from free running. (Example 1) 0-Hz start (Example 2): Frequency matching start FW FW FRS FRS Free running 0-Hz start Free running Motor rpm Motor rpm 0 0 4 b003 Frequency matching start • When the FRS terminal is turned off and the retry wait time elapses, the motor frequency is matched and a Active Frequency Matching starts without stopping the motor. If an overcurrent trip occurs at frequency matching start, extend the retry wait time. • Even if "frequency matching start" is selected, the Inverter may start at 0 Hz when: • The output frequency is equal to or lower than 1/2 of the base frequency • The motor induction voltage quickly attenuates • The Inverter detects a frequency equal to or lower than the frequency matching lower limit frequency setting (b007) (Example 3) Active Frequency Matching restart • After the retry wait time (b003) elapses, the Inverter starts output from the b030 set value. The Inverter then decelerates according to b029, while keeping the output current at the b028 set value. b028 • When the frequency matches the voltage, the Inverter accelerates again, and then output Decelerates according to b029. frequency is restored to the original level. • If an overcurrent trip occurs under this method, reduce the b028 set value. FW RS Output current Inverter output frequency Frequency selected in b030 Trip occurs Motor rpm b003 4-72 Functions • The Inverter starts running at 0 Hz regardless of the motor rpm. The retry wait time is ignored at 0-Hz start. • If the Inverter starts running at 0 Hz with the motor rpm high, an overcurrent trip may occur. 4-2 Function Mode Automatic Carrier Frequency Reduction Function •This function automatically reduces carrier frequency according to an increase in output current. •This function is enabled when automatic carrier frequency reduction selection b089 is set to "01". Parameter No. Function name Data b089 Automatic carrier reduction 00: OFF (Disabled) 01: ON (Enabled) Default setting Unit 00  •When output current exceeds 60%, 72%, 84% and 96% of the rated current, the carrier frequency is reduced to 12, 9, 6, and 3 kHz, respectively. When the output current falls below -5% of each level, this function will be reset. Functions 4 Carrier frequency reduction starting level (Recovery level) Reduced carrier frequency (kHz) Less than 60% of the rated current 15.0 60% (55%) of the rated current 12.0 72% (67%) of the rated current 9.0 84% (79%) of the rated current 6.0 96% (91%) of the rated current 3.0 Carrier frequency 15.0 kHz 12.0 kHz 9.0 kHz 6.0 kHz 3.0 kHz 0 50 100 Output current (%) 60% 72% 84% 96% •The carrier frequency reduction rate is 2 kHz per second. •The upper limit of carrier frequency variable with this function conforms to the set value of carrier frequency b083, and the lower limit is 3 kHz. Note: When b083 is 3 kHz or lower, this function is disabled regardless of the b089 setting. 4-73 4-2 Function Mode Regenerative Braking Function •This function applies to the Inverter models with a built-in regenerative braking circuit (3G3RX-A2220/A4220 or lower models). •With the built-in regenerative braking circuit, this function allows an external braking resistor to consume the motor's regeneration energy as heat. This function is useful for a system in which the motor works as a generator when it is rapidly decelerated. •To use this function, configure the following settings. Parameter No. Function name Data Default setting Unit 0.0: Does not operate. 0.0 to 100.0: A regenerative braking usage rate for 100 seconds can be set, in increments of 0.1%. If the set usage rate is exceeded, a braking resistor overload trip (E06) occurs. t1 t2 t3 ON ON ON 0.0 % Regenerative 00: OFF (Disabled) braking function 01: RUN-ON (Enabled (Disabled during stop)) operation selection 02: Alws-ON (Enabled (Enabled during stop)) 00  200-V class: 330 to 380 * 400-V class: 660 to 760 * (Inverter DC voltage) 200-V class: 360 V 400-V class: 720 V V Regenerative braking function activated Usage rate (%) = b095 Regenerative braking function ON level b096 100 s (t1 + t2 + t3) 100 s × 100 * The regenerative braking function ON level conforms to the voltage setting for the Inverter's internal converter (DC unit). Cooling Fan Control •You can set whether to operate the Inverter's cooling fan constantly or only during Inverter operation. Parameter No. b092 Function name Data Default setting Unit Cooling fan control 00: Alws-ON (Always ON) 01: ON in RUN (ON during RUN) Regardless of the settings, the cooling fan operates for 5 minutes after power-on, and for 5 minutes after the Inverter stops. 01  Note: If a momentary power interruption occurs or the power is shut off while the cooling fan is in operation, the cooling fan stops temporarily and restarts automatically after power recovery. 4-74 Functions Usage rate of regenerative braking function b090 4 4-2 Function Mode External Thermistor (TH) •This function enables thermal protection of the external equipment (e.g. motor) if its internal thermistor is connected to the Inverter. Parameter No. Function name b098 Thermistor selection 00: Disabled 01: PTC enabled 02: NTC enabled b099 Thermistor error level 0 to 9999: Set a temperature resistance value to trip the Inverter, according to the specifications of your thermistor. C085 Thermistor adjustment 0.0 to 1000.0: Used for gain adjustment. Functions 4 Data Default setting Unit 00  3000  Factory default  Note: If thermistor selection b098 is set to "01" without connecting an external thermistor, the Inverter trips. •Connect an external thermistor between control terminals TH and CM1. •Set the following functions according to the specifications of your thermistor. •When this function is used, keep the cable length between the motor and Inverter within 20 m. Since the current flowing through the thermistor is weak, you must take measures to prevent noise due to motor current. (For example, place the thermistor cable away from the motor cable.) 4-75 4-2 Function Mode Brake Control Function •This function allows the Inverter to control the external brake of equipment, including an elevating system. When brake control selection b120 is set to "01" (enabled), the Inverter operates as follows: b0125 Brake release frequency b127 Brake input frequency (7) Output frequency (1) RUN command (5) (2) Brake release signal b121 Brake wait time for release b123 Brake wait time for stopping (4) b122 Acceleration wait time Brake confirmation signal (3) b124 Brake confirmation wait time (6) b124 Brake confirmation wait time Note: The above operation chart applies to a case where the brake confirmation signal (44: BOK) is selected for any of multi-function inputs 1 to 8 (C001 to C008). If BOK is not selected, the acceleration wait time (b122) starts at the brake release signal ON timing. The stop wait time (b123) starts at the brake release signal OFF timing. •To use the brake control function, allocate the following functions to multi-function I/O terminals, as required. •To input a brake release signal from an external brake to the Inverter, allocate the brake confirmation signal (44: BOK) to any of multi-function inputs 1 to 8 (C001 to C008). 4-76 4 Functions (1) At RUN command input, the Inverter starts output, and accelerates to the release frequency. (2) After the release frequency is reached, the Inverter outputs the brake release signal (BRK) after the brake release establishment wait time (b121) elapses. However, if the Inverter's output current is less than the current value set in release current b126, the Inverter does not output the brake release signal. In this case, the Inverter trips, and outputs the brake error signal (BER). (3) If the brake confirmation signal (BOK) is allocated to a multi-function input (when "44" is set in any of C001 to C008), the Inverter waits for the brake confirmation signal for the period set in brake confirmation wait time b124 without accelerating, after the brake release signal is output. If the brake confirmation signal does not turn on within the period set in b124, the Inverter outputs the brake error signal (BER), resulting in trip. If the brake confirmation signal is not allocated to a multi-function input, brake confirmation wait time b124 is disabled, and the Inverter performs processing (4) after the brake release signal is output. (4) After the brake confirmation signal is input (or after the brake release signal is output if BOK is not selected), the Inverter restarts acceleration up to a set frequency after the period set in acceleration wait time b122 elapses. (5) After the RUN command is turned off, the Inverter decelerates to the brake release frequency (b125), and turns off the brake release signal (BRK). (6) If the brake confirmation signal (BOK) is allocated to a multi-function input (when "44" is set in any of C001 to C008), the Inverter waits for the brake confirmation signal to be turned off for the period set in brake confirmation wait time b124 without decelerating, after the brake release signal is turned off. If the brake confirmation signal is not turned off within the period set in b124, the Inverter outputs the brake error signal (BER), resulting in trip. If the brake confirmation signal is not allocated to a multi-function input, brake confirmation wait time b124 is disabled, and the Inverter performs processing (7) after the brake release signal is turned off. (7) After the brake confirmation signal is turned off (or after the brake release signal is turned off if BOK is not selected), the Inverter restarts deceleration down to 0 Hz after the period set in stop wait time b123 elapses. 4-2 Function Mode •Allocate the brake release signal (19: BRK) to any of multi-function output terminals 11 to 15 (C021 to C025). Also, to use a brake error output signal, allocate the brake error signal (20: BER). •To use the brake control function, you are recommended to select "sensorless vector control" (A044 = 03), "0-Hz sensorless vector control" (A044 = 04), or "sensor vector control" (A044 = 05) so that the Inverter outputs high torque during startup. (Refer to page 4-21.) Parameters Required for Brake Control Function Parameter No. Function name b120 Brake control selection Default setting Unit 00  b121 Brake wait time for release 0.00 to 5.00: Set a time required for the output current to reach the rate of the release current after reaching the release frequency. 0.00 s b122 Brake wait time for acceleration 0.00 to 5.00: Set a mechanical delay time from when the release signal is output until the brake is released. 0.00 s b123 Brake wait time for stopping 0.00 to 5.00: Set a mechanical delay time from when the release signal is turned off until the brake is closed. 0.00 s b124 Brake wait time for confirmation 0.00 to 5.00: Set a wait time longer than the time from when the release signal is released until the brake outputs the release completion signal to the Inverter. 0.00 s b125 Brake release frequency 0.00 to -400.00: Set a frequency to output the brake release signal. *1 0.00 Hz b126 Brake release current 0.0 to 2.00 x Rated current (0.4 to 55 kW) 0.0 to 1.80 x Rated current (75 to 132 kW) Rated current  b127 Brake input frequency 0.00 to 400.00: Set a frequency to close the brake during stop. *1 0.00 Hz Functions 4 Related functions Data 00: OFF (Disabled) 01: ON (Enabled) C001 to C008, C021 to C025 *1. Set a brake release frequency higher than the starting frequency (b082). *2. If the set current is too low, sufficient torque may not be provided when the brake is released. In any of the following cases, the Inverter trips and outputs the brake error signal (BER). (Brake error: E36) •The output current is lower than the release current after the brake release establishment wait time (b121) elapses. •When the brake confirmation (BOK) signal is used, the brake confirmation signal does not turn on within the brake confirmation wait time (b124) during acceleration, or does not turn off within the brake confirmation wait time (b124) during deceleration; or the brake confirmation signal turns off, although the brake release signal is output. 4-77 4-2 Function Mode Overvoltage Protection Function During Deceleration •This function helps avoid an overvoltage trip due to regenerative energy from the motor during deceleration. •You can set whether to enable or disable this function with overvoltage protection function selection during deceleration b130. •If overvoltage protection function selection b130 is set to "01" (enabled: DC voltage constant control), the Inverter automatically decelerates while keeping the main circuit DC voltage rise due to deceleration start at the overvoltage protection function level setting (b131). •If overvoltage protection function selection b130 is set to "02" (enabled: with acceleration), the main circuit DC voltage increases because of deceleration start. When the main circuit DC voltage exceeds the overvoltage protection function level setting (b131), the Inverter starts acceleration according to the setting of overvoltage protection parameter b132. After that, when the main circuit DC voltage falls below the b131 level, the Inverter starts deceleration again. Function name Data Default setting Unit b130 Overvoltage protection function selection during deceleration 00: OFF (Disabled) 01: V-const (DC voltage kept constant) (example 1) *2 02: Accel (Acceleration enabled) (example 2) 01  b131 Overvoltage protection level during deceleration *1 200-V class: 330 to 390 400-V class: 660 to 780 380/760 V b132 Overvoltage protection parameter 0.10 to 30.00: Set the acceleration rate applied when this function is enabled. 1.00 s b133 0.00 to 2.55: Overvoltage protection Proportional gain for DC voltage constant proportional gain setting control (b130 = 01 only) 0.50  b134 Overvoltage protection integral time setting 0.060 s 0.000 to 65.535: Integral time for DC voltage constant control (b130 = 01 only) (Example 1) When b130 = 01 (Example 2) When b130 = 02 Main circuit DC voltage (V) Main circuit DC voltage (V) Overvoltage protection level (b131) Overvoltage protection level (b131) Time (s) Output frequency (Hz) Time (s) Output frequency (Hz) DC voltage kept constant Deceleration started Deceleration started Accelerates according to b132. Time (s) Time (s) Note 1: With this function enabled, the actual deceleration time may be longer than the set value. Particularly with b130 = 02, if b131 is set too low, the Inverter may not decelerate. Note 2: Even if this function is enabled, an overvoltage trip may occur depending on the deceleration rate and load condition. Note 3: When using this function, the Inverter may reduce frequency depending on the moment of inertia of motor load, and takes a long time to stop. 4-78 Functions Parameter No. 4 4-2 Function Mode *1. If the b131 set value is lower than the incoming voltage or equivalent, the motor may not be stopped. *2. When b130 = 01, PI control works to keep the internal DC voltage constant. •Though quicker response is expected with a larger proportional gain (b133), control tends to be divergent and may easily lead to a trip. •Response also becomes quicker with a shorter integral time (b134), but if too short, the same situation may occur. The RX has eight input terminals [1], [2], [3], [4], [5], [6], [7], and [8]; five open collector output terminals [11], [12], [13], [14], and [15]; one relay output terminal [AL2] and [AL1] (SPDT contact); two analog output terminals [AM] and [AMI]; as well as one digital output terminal [FM]. 4 Functions Multi-function Input Selection •You can use the following functions by allocating them to any of multi-function inputs 1 to 8. To allocate the functions, set the following data in C001 to C008. For example, C001 corresponds to input terminal 1. •The same two functions cannot be allocated to the multi-function input terminals. If you attempt to allocate the same two functions to the terminals by mistake, the terminal where you allocated the function last takes precedence. The previous data is set to "no (no allocation)", and the terminal function is disabled. •After allocating functions to terminals 1 to 8, make sure that the function settings have been stored. Parameter No. C001 to C008 4-79 Data Function name 01 RV : Reverse 02 CF1 : Multi-step speed setting binary 1 03 CF2 : Multi-step speed setting binary 2 04 CF3 : Multi-step speed setting binary 3 05 CF4 06 Reference item RUN command Page  Multi-step speed operation function 4-16 : Multi-step speed setting binary 4 Multi-step speed operation function 4-16 JG : Jogging Jogging operation 4-18 07 DB : External DC injection braking DC injection braking (external DC injection braking) 4-24 08 SET : 2nd control 2nd/3rd control function 4-82 09 2CH : 2-step acceleration/deceleration 2-step acceleration/deceleration function 4-37 11 FRS : Free-run stop Free-run stop 4-71 12 EXT : External trip External trip 4-84 13 USP : USP function Power recovery restart prevention function 4-84 14 CS : Commercial switch Commercial switch 4-85 4-2 Function Mode Parameter No. Function name Reference item Page 15 SFT : Soft lock Soft lock 4-51 16 AT : Analog input switching External analog input 4-12 17 SET3 : 3rd control 2nd/3rd control function 4-82 18 RS : Reset Reset 4-87 20 STA : 3-wire start 21 STP : 3-wire stop 3-wire input function 4-88 22 F/R : 3-wire forward/reverse 23 PID : PID enabled/disabled PID function 4-31 Control gain switching 4-89 UP/DOWN function 4-90 Forced operator function 4-91 Multi-step speed operation function 4-16 Overload limit 4-49 Torque limit function 4-57 P/PI switching function 4-92 24 PIDC : PID integral reset 26 CAS : Control gain switching 27 UP : UP/DWN function accelerated 28 DWN : UP/DWN function decelerated 29 UDC : UP/DWN function data clear 31 OPE : Forced operator 32 SF1 : Multi-step speed setting bit 1 33 SF2 : Multi-step speed setting bit 2 34 SF3 : Multi-step speed setting bit 3 35 SF4 : Multi-step speed setting bit 4 36 SF5 : Multi-step speed setting bit 5 37 SF6 : Multi-step speed setting bit 6 38 SF7 : Multi-step speed setting bit 7 39 OLR : Overload limit switching 40 TL : Torque limit enabled 41 TRQ1 : Torque limit switching 1 42 TRQ2 : Torque limit switching 2 43 PPI 44 BOK : Brake confirmation Brake control function 4-76 45 ORT : Orientation Orientation function 4-134 46 LAC : LAD cancel LAD cancel function 4-9 47 PCLR : Position deviation clear STAT : Pulse train position command input permission V2 control mode selection 4-124 48 50 ADD : Frequency addition Set frequency addition function 4-41 51 F-TM : Forced terminal block Forced terminal function 4-93 52 ATR : Torque command input permission Torque control 4-126 53 KHC : Integrated power clear Integrated power 54 SON : Servo ON Servo ON function : P/PI switching 4-4 4-143 4-80 4 Functions C001 to C008 Data 4-2 Function Mode Parameter No. Functions 4 C001 to C008 Data Function name 55 FOC : Preliminary excitation 56 MI1 : Drive Programming input 1 57 MI2 : Drive Programming input 2 58 MI3 : Drive Programming input 3 59 MI4 : Drive Programming input 4 60 MI5 : Drive Programming input 5 61 MI6 : Drive Programming input 6 62 MI7 : Drive Programming input 7 63 MI8 : Drive Programming input 8 65 AHD : Analog command held 66 CP1 : Position command selection 1 67 CP2 : Position command selection 2 68 CP3 : Position command selection 3 69 ORL : Zero return limit signal 70 ORG : Zero return startup signal 71 FOT : Forward driving stop 72 ROT : Reverse driving stop 73 SPD : Speed/Position switching 74 PCNT : Pulse counter 75 PCC : Pulse counter clear 82 PRG : Drive program start no NO Reference item Page Preliminary excitation function 4-119 Drive Programming input 1 to 8  Analog command held 4-93 4-139 Absolute position control mode  4-142 4-140 Multi-function pulse counter 4-94  Drive program start  : No allocation  •You can select NO- or NC-contact input for each multi-function input terminal. Parameter No. Function name C011 to C018 Multi-function input 1 to 8 operation selection C019 FW terminal operation selection Related functions 4-81 Data 00: NO 01: NC • You can set NO- and NC-contact inputs individually for multi-function input terminals 1 to 8 and the FW terminal. • NO contact: "ON" with the contact closed, "OFF" with the contact open. • NC contact: "ON" with the contact open. "OFF" with the contact closed. • A terminal with reset (RS) setting function only can be set as NO contact. C001 to C008 Default setting Unit 00  00  4-2 Function Mode 2nd/3rd Control Function •You can switch between three motors to control the Inverter by allocating 08 (SET)/17 (SET3) to any of multi-function inputs 1 to 8 (C001 to C008) and then turning on/off the SET/SET3 terminal. Parameter No. C001 Function name Multi-function input 1 selection *1 Multi-function input 2 selection C003 Multi-function input 3 selection *1 C004 Multi-function input 4 selection C005 Multi-function input 5 selection C006 Multi-function input 6 selection C007 Multi-function input 7 selection C008 Multi-function input 8 selection 01: RV (reverse) 02: CF1 (multi-step speed setting binary 1) 03: CF2 (multi-step speed setting binary 2) 04: CF3 (multi-step speed setting binary 3) 05: CF4 (multi-step speed setting binary 4) 06: JG (jogging) 07: DB (external DC injection braking) 08: SET (2nd control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (free-run stop) 12: EXT (external trip) 13: USP (USP function) 14: CS (commercial switch) 15: SFT (soft lock) 16: AT (analog input switching) 17: SET3 (3rd control) 18: RS (reset) 20: STA (3-wire start) 21: STP (3-wire stop) 22: F/R (3-wire forward/reverse) 23: PID (PID enabled/disabled) 24: PIDC (PID integral reset) 26: CAS (control gain switching) 27: UP (UP/DWN function accelerated) 28: DWN (UP/DWN function decelerated) 29: UDC (UP/DWN function data clear) 31: OPE (forced operator) 32: SF1 (multi-step speed setting bit 1) 33: SF2 (multi-step speed setting bit 2) 34: SF3 (multi-step speed setting bit 3) 35: SF4 (multi-step speed setting bit 4) 36: SF5 (multi-step speed setting bit 5) 37: SF6 (multi-step speed setting bit 6) 38: SF7 (multi-step speed setting bit 7) 39: OLR (overload limit switching) 40: TL (torque limit enabled) 41: TRQ1 (torque limit switching 1) 42: TRQ2 (torque limit switching 2) 43: PPI (P/PI switching) 44: BOK (brake confirmation) 45: ORT (orientation) 46: LAC (LAD cancel) 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission) 50: ADD (frequency addition) 51: F-TM (forced terminal) 52: ATR (torque command input permission) 53: KHC (integrated power clear) 54: SON (servo ON) 55: FOC (preliminary excitation) 56: MI1 (drive programming input 1) 57: MI2 (drive programming input 2) 58: MI3 (drive programming input 3) 59: MI4 (drive programming input 4) 60: MI5 (drive programming input 5) 61: MI6 (drive programming input 6) 62: MI7 (drive programming input 7) 63: MI8 (drive programming input 8) 65: AHD (analog command held) 66: CP1 (position command selection 1) 67: CP2 (position command selection 2) 68: CP3 (position command selection 3) 69: ORL (zero return limit signal) 70: ORG (zero return startup signal) 71: FOT (forward driving stop) 72: ROT (reverse driving stop) 73: SPD (speed/position switching) 74: PCNT (pulse counter) 75: PCC (pulse counter clear) 82: PRG (drive program start) no: NO (no allocation) Default setting Unit 01 4 12 Functions C002 Data 18 02  03 06 08 no *1. When the emergency shutoff function is enabled (SW1 = ON), C001 and C003 are forced to change to "18" (RS) and "64" (EMR), respectively. (You cannot intentionally set "64".) If SW1 is turned on and then off, C003 is set to "no" (no allocation). 4-82 4-2 Function Mode The functions switchable via the SET/SET3 terminal are: : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd A047/A247 * : 1st/2nd A061/A261 * A062/A262 * A092/A292/A392 * A093/A293/A393 * A094/A294 : 1st/2nd : 1st/2nd : 1st/2nd/3rd : 1st/2nd/3rd : 1st/2nd A095/A295 A096/A296 b012/b212/b312 * b013/b213/b313 * : 1st/2nd : 1st/2nd : 1st/2nd/3rd : 1st/2nd/3rd H002/H202 H003/H203 H004/H204 H005/H205 * H006/H206/H306 * H020/H220 H021/H221 H022/H222 H023/H223 H024/H224 H030/H230 H031/H231 H032/H232 H033/H233 H034/H234 H050/H250 * H051/H251 * H052/H252 * H060/H260 * : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd/3rd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd : 1st/2nd acceleration time deceleration time base frequency maximum frequency multi-step speed reference 0 torque boost selection manual torque boost voltage manual torque boost frequency V/f characteristics selection automatic torque boost voltage compensation gain automatic torque boost slip compensation gain frequency upper limit frequency lower limit acceleration time 2 deceleration time 2 2-step acceleration/deceleration selection 2-step acceleration frequency 2-step deceleration frequency electronic thermal level electronic thermal characteristics selection motor parameter selection motor capacity selection motor pole number selection speed response stabilization parameter motor parameter R1 motor parameter R2 motor parameter L motor parameter I0 motor parameter J motor parameter R1 (auto-tuning) motor parameter R2 (auto-tuning) motor parameter L (auto-tuning) motor parameter I0 (auto-tuning) motor parameter J (auto-tuning) PI proportional gain PI integral gain P proportional gain Limit at 0 Hz U/T1 V/T2 W/T3 Motor 1 Motor 2 Inverter Functions 4 F002/F202/F302 * F003/F203/F303 * A003/A203/A303 A004/A204/A304 A020/A220/A320 * A041/A241 A042/A242/A342 * A043/A243/A343 * A044/A244/A344 A046/A246 * Motor 3 SET SET3 P24 *: Parameters changeable during operation. • The 1st/2nd/3rd control functions are displayed identically. You'll see which one is enabled by checking whether the terminal is turned on/off. • When both SET and SET3 terminals are turned on, priority is given to SET, and the 2nd control function is enabled. • During operation, you cannot switch between the 1st, 2nd, and 3rd control functions. You can switch them only during stop. 4-83 4-2 Function Mode External Trip •This function trips the Inverter via an error (trip) signal from a peripheral system. To use this function, allocate "12" (EXT) to any of multi-function inputs 1 to 8 (C001 to C008). Data Symbol Function name 12 EXT External trip Status Description ON Sets the motor to free-run status by shutting off output. OFF The motor is in normal operation. Available input terminals C001 to C008 Note: Do not turn on the EXT terminal after shutting off the power. Otherwise, the Inverter may not store data correctly. Power Recovery Restart Prevention Function RUN commands FW, RV EXT terminal Free running Motor rpm RS terminal Alarm output terminal •This function trips the Inverter, displaying "E13", if the power is turned on with the RUN command to the Inverter turned on. Data 13 Symbol USP Available input terminals Function name Status Description ON Does not start the Inverter with the power turned on while the RUN command is input. OFF Starts the Inverter with the power turned on while the RUN command is input. USP function C001 to C008 •To reset a trip, perform the reset operation, or turn off the RUN command. (Example 1) •If a trip is reset with the RUN command input turned on, the Inverter restarts operation immediately after the trip is reset. (Example 2) •If the RUN command is turned on after the power is turned on, the Inverter operates normally. (Example 3) •Allocate 13 (USP) to any of multi-function inputs 1 to 8 (C001 to C008). 4-84 Functions •When the EXT terminal is turned on, E12 is displayed and the Inverter trips to stop output. •When the Inverter has tripped, indicating E12, the trip is not reset even if the error signal from external equipment is reset (EXT terminal is turned off). To reset the trip, perform the reset operation or turn the power off and on again. 4 4-2 Function Mode •The following shows how the power recovery restart prevention function works. 4 (Example 1) Power supply (Example 2) Power supply (Example 3) Power supply FW FW FW USP USP USP RS RS RS Alarm Alarm Alarm Output frequency Output frequency Output frequency Functions Commercial Switching •You can use this function to drive a system with large moment of inertia during acceleration and deceleration by using the Inverter, and during constant speed by using a commercial power supply. •Allocate "14" (CS) to any of multi-function inputs 1 to 8 (C001 to C008). •When the CS terminal is turned on and then off with the RUN command turned on, the Inverter starts acceleration in synchronization with the motor rpm during free running, after the retry wait time (b003) elapses (frequency matching start). Note that the Inverter may start at 0 Hz if: • The motor rpm is equal to or lower than 1/2 of the base rpm • The motor induction voltage quickly attenuates •If frequency matching lower limit frequency setting b007 is set, the Inverter starts at 0 Hz when the motor rpm lowers to the frequency set in b007. (Refer to page 4-38) •Ensure that MC3 and MC2 are mechanically interlocked. •If the earth leakage breaker (ELB) has tripped because of ground fault, the commercial power supply circuit does not work, either. If you need backup, supply power from a commercial power supply circuit (ELBC). •For FWY, RVY, and CSY, use low current relays. Refer to the following sequence for timing. •If an overcurrent trip occurs at frequency matching, extend the retry wait time (b003). •For commercial switching operation, refer to the following examples of connections and timing of commercial switching operation. •At power-on, the Inverter can automatically perform retry operation. This does not require the following CS terminal. For details, refer to "Reset" (page 4-87). Examples of connections and timing of commercial switching operation MC2 NFB ELBC MC1 MC3 R/L1 S/L2 T/L3 U V W Ro To H O L AL2 FWY RVY FW RV CSY CS P24 4-85 AL1 AL0 THRY Motor 4-2 Function Mode Timing example of switching from Inverter to commercial power MC1 ON MC2 ON MC1 MC2 MC3 ON MC3 FW ON FW CS Inverter output Operation frequency ON CS Timing example of switching from commercial power to Inverter ON Interlock time of MC2 and MC3 (0.5 to 1 s) ON ON OFF Retry wait time b003 0.5 to 1 s Operation Operates after frequency matching. 4 Functions 4-86 4-2 Function Mode Reset •This function resets an Inverter trip. Parameter No. Function name b003 Retry wait time 0.3 to 100.0: (Refer to "Momentary Power Interruption/ Trip Retry (Restart)" (page 4-42).) Time from reset to restart b007 Frequency matching lower limit frequency setting 0.00 to 400.00: (Refer to "Momentary Power Interruption/ Trip Retry (Restart)" (page 4-42).) 4 Functions Data Default setting Unit 1.0 s 0.00 Hz 00  00  00: ON-RESET (Trip reset at power-on) (example 1) Normal: Output shut off Abnormal: Trip reset 01: OFF-RESET (Trip reset when the power is OFF (example 2) Normal: Output shut off Abnormal: Trip reset C102 Reset selection 02: On in Trip (Enabled only during trip (Reset when the power is OFF)) (example 1) Normal: Disabled Abnormal: Trip reset 03: Trip RESET (Trip reset only) (example 1) The Inverter does not initialize internal data at trip reset. Normal: Disabled Abnormal: Trip reset C103 Reset frequency matching selection 00: 0 Hz start 01: f-match (Frequency matching start) (example 3) 02: Actv. f-match (Active Frequency Matching restart) •To reset an Inverter trip, press the STOP/RESET key on the Digital Operator, or switch the RS terminal from ON to OFF. •To reset via the control circuit terminal block, allocate 18 (RS) to the desired multi-function input. •With reset frequency matching selection C103, you can select how to restart the Inverter after reset, a frequency matching or 0-Hz start. If an overcurrent trip occurs at frequency matching start, increase the retry wait time (b003). •You can select an alarm reset timing in reset selection C102. In addition, you can enable the reset signal only for alarm resetting during error. •For the RS terminal, only NO contact is available. Note: Do not use the reset terminal to shut off the Inverter output. Reset operation clears the internal data (e.g. electronic thermal BRD counter), causing damage to the Inverter. (Example 1) 4-87 (Example 2) RS RS Alarm Alarm 4-2 Function Mode (Example 3) If "01" (frequency matching start) is selected in reset frequency matching selection C103, frequency matching start is also enabled when the power is turned on again. When C103 = 00 (0-Hz start), the retry wait time (b003) is ignored. Even if "frequency matching start" is selected, however, the Inverter may start at 0 Hz if: • The output frequency is equal to or lower than 1/2 of the base frequency • The motor induction voltage quickly attenuates Power supply FW Frequency matching Free running Motor rpm 4 (Example 4) Active Frequency Matching restart FW RS b028 Output current Decelerates according to b029. Inverter output frequency • After the retry wait time (b003) elapses, the Inverter starts output from the b030 set value. The Inverter then decelerates according to the b029 setting, while keeping the output current at the b028 set value. • When the frequency matches the voltage, the Inverter accelerates again, and the frequency is restored to the original level. • If an overcurrent trip occurs under this method, reduce the b028 setting. Frequency selected in b030 Trip occurs Motor rpm b003 Note: If a reset signal is input during the retry wait time, the value of "frequency at interruption" stored in the Inverter is cleared, resulting in a 0-Hz start. 3-wire Input Function •This function helps start and stop the Inverter using an auto-recovery contact (e.g. pushbutton switch). Data Symbol Function name 20 STA 3-wire start 21 22 STP F/R Status Description ON Starts with auto recovery contacts. OFF Irrelevant to the motor operation. ON Stops with auto recovery contacts. OFF Irrelevant to the motor operation. ON Reverse OFF: Forward 3-wire stop 3-wire forward/reverse Available input terminals C001 to C008 Required settings A002 = 01 •Set RUN command selection A002 to 01 (control circuit terminal block). 4-88 Functions Note: The counters used for the Inverter's internal protection are cleared during reset. To shut off the Inverter's output via a multi-function input terminal, use the free-run stop terminal (FRS). 4-2 Function Mode •The following operations become possible when 20 (STA), 21 (STP), and 22 (F/R) are allocated to any of multi-function inputs 1 to 8 (C001 to C008). Allocating the STP terminal disables the FW and RV terminals. •Below are the outputs via terminal operation. STA ON ON STP Functions 4 OFF OFF F/R Forward Output frequency Reverse Control Gain Switching Function •This function provides two types of gain and time constant settings for the speed control system (proportional/integral compensation). You can switch over these settings when "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control method. Parameter No. A044/A244 Function name Data Default setting Unit 00    0.001 to 80.000 1.590  03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector V/f characteristics selection control) 05: V2 (Sensor vector control) C001 to C008 Multi-function inputs 1 to 8 selection H005/H205 Speed response H050/H250 PI proportional gain 0.0 to 1000.0 100.0 % H051/H251 PI integral gain 0.0 to 1000.0 100.0 % H052/H252 P proportional gain 0.01 to 10.00 1.00  H070 For PI proportional gain switching 0.0 to 1000.0 100.0 % For PI integral gain switching 0.0 to 1000.0 100.0 % 0.00 to 10.00 1.00  0 to 9999 (ms): Taper time during gain switching 100 ms H071 H072 For P proportional gain switching H073 Gain switching time 26: CAS (control gain switching) •If control gain switching is selected in the multi-function input selection, turning off the signal selects the gain setting of H050, H250, H051, H251, H052, or H252. Turning on the signal selects the gain setting of H070, H071, or H072. •If control gain switching is not selected in multi-function inputs 1 to 8 (C001 to C008), the gain setting conforms to the status in which the signal is turned off. 4-89 4-2 Function Mode UP/DOWN Function •This function allows you to change the Inverter output frequency using the UP and DWN terminals of the multi-function inputs. Data Symbol 27 UP 28 DWN 29 UDC UP/DWN function accelerated UP/DWN function decelerated UP/DWN function data clear Status Description ON Increases the current speed during the signal input period. OFF Keeps the current speed. ON Decreases the current speed during the signal input period. OFF Keeps the current speed. ON Clears the stored UP/DWN speed. OFF Keeps the stored UP/DWN speed. 4 C001 to C008 Note: Do not turn on/off the UP/DWN terminal after shutting off the power. Otherwise, the Inverter may not store data correctly. •Allocate "27" (UP) and "28" (DWN) to any of multi-function inputs 1 to 8 (C001 to C008). •This function is enabled only when frequency reference selection A001 is set to "01" or "02". If "01" (terminal) is selected, however, this function is enabled for multi-step speed operation only. •When you use an external analog input as frequency reference input, or when you set the jogging operation frequency, this function is disabled. •While the UP/DWN terminal is turned on, the acceleration/deceleration time depends on F002, F003/F202, F203/F302, and F303. To switch between the 1st/2nd/3rd controls, allocate 08 (SET)/ 17 (SET3) to the desired multi-function input and then turn on/off the SET terminal. •You can store a frequency set value after UP/DWN adjustment. Choose whether to store the value with C101. Also, you can clear the stored frequency set value. By allocating "29" (UDC) to a multi-function input and turning on/off the UDC terminal, you can clear or store the frequency reference setting adjusted at UP/DOWN. Parameter No. Data Description 00 Does not store the frequency reference adjusted at UP/DWN. After restoring the power, returns to the value set before UP/DWN adjustment. 01 Stores the frequency reference adjusted at UP/DWN. After restoring the power, maintains the set value after UP/DWN adjustment. C101 RUN command (FW, RV) UP DWN Acceleration/Deceleration does not occur if the UP and DWN terminals turn on simultaneously. Output frequency 4-90 Functions Available input terminals Function name 4-2 Function Mode Forced Operator Function •This function forcibly enables operation via the Digital Operator by turning on/off the multi-function terminal if the frequency reference/RUN command sources are not set to the Digital Operator. Data Symbol 31 OPE Function name Status Description ON Prioritizes the command from the Digital Operator (A020, A220 set values) over the A001 and A002 settings. OFF Operates according to the A001 and A002 settings. Forced operator Available input terminals C001 to C008 Related codes A001, A002 4 Functions •If the Forced Operator function is selected in the multi-function input selection, the Inverter is operated with the signal from the frequency reference source and RUN command source selected in A001 and A002, when the input signal is OFF. When the signal is ON, the Inverter is forced to operate with the frequency reference or RUN command from the Digital Operator. •If you switch on/off this function during operation, the RUN command is reset to stop the Inverter output. Before resuming operation, turn off the RUN command from each command source to avoid possible danger and then input it again. 4-91 4-2 Function Mode P/PI Switching Function •This function allows you to switch the control (compensation) method for the speed control system between proportional integral compensation and proportional compensation, when "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control method. Parameter No. Function name Data Default setting Unit 03: SLV (Sensorless vector control) (A344 is blank.) 04: 0SLV (0 Hz sensorless vector control) (A344 is blank.) 05: V2 (Sensor vector control) 00  43: PPI (P/PI switching)   0.001 to 80.000 1.590  A044/A244/A344 V/f characteristics selection C001 to C008 Multi-function inputs 1 to 8 selection H005/H205 Speed response H050/H250 PI proportional gain 0.0 to 1000.0 100.0 % H051/H251 PI integral gain 0.0 to 1000.0 100.0 % H052/H252 P proportional gain 0.01 to 10.00 1.00  4 Normally, the Inverter performs proportional integral compensation (PI control) for speed control so that the difference between frequency reference and actual rpm becomes zero. If one load is operated by several motors, however, proportional control (P control) may be required. To enable proportional control (P control), allocate the P/PI switching function to any of multifunction input terminals 1 to 8 (set "43" in any of C001 to C008) via the Digital Operator, and turn on the terminal. If you choose to enable proportional control, set a "KPP" value in H052 (P proportional gain). P control PI control Torque (A) 100% The relationship between the KPP value and speed change ratio is expressed broadly in the following formula: rpm 0 10 (Speed change ratio) = (KPP set value) % The relationship between speed change ratio and speed error is expressed broadly in the following formula: Speed error at rated torque (A) (Speed change ratio) = Synchronous rpm at base frequency × 100% 4-92 Functions •If P/PI switching is selected in the multi-function input selection, proportional integral compensation is enabled while the signal is off; proportional compensation is enabled while the signal is on. If P/PI switching is not selected in multi-function inputs 1 to 8 (C001 to C008), proportional integral compensation is enabled. 4-2 Function Mode Forced Terminal Block Function (F-TM) •This function forcibly enables operation via the control terminal block by turning on/off the multifunction terminal if the frequency reference/RUN command sources are not set to the control terminal block. Data Symbol 51 F-TM Multi-function input selection Description Forced terminal Available input terminals C001 to C008 Related codes A001, A002 •If the Forced Terminal Block function is selected in the multi-function input selection, the Inverter is operated with the signal from the frequency reference source and RUN command source selected in A001 and A002, when the input signal is OFF. When the signal is ON, the Inverter is forced to operate with the frequency reference or RUN command from the control circuit terminal block. •If you switch on/off this function during operation, the RUN command is reset to stop the Inverter output. Before resuming operation, turn off the RUN command from each command source to avoid possible danger and then input it again. 4 Functions Function name Analog Command Hold Function •While the AHD terminal is turned on, the Inverter keeps external analog input results on hold. Parameter No. Function name C001 to C008 Multi-function inputs 1 to 8 selection Data 65: AHD (analog command held) Default setting Unit   •While the AHD terminal is turned on, you can use the UP/DWN function based on the reference value of the analog signal kept on hold by this function. •If UP/DWN selection C101 is set to "01", the Inverter can store an UP/DWN result. •If the power is turned on with the AHD terminal turned on, or if the RS terminal is turned on and then off, the Inverter employs the data kept on hold immediately before. AHD terminal ON Analog input value Frequency reference Note1: If the control function is switched via the SET/SET3 terminal with the AHD terminal turned on, the set frequency is retained. To change the control function, turn off the AHD terminal once, and keep the analog signal on hold again. Note 2: If this function is frequently used, the internal storage element service life may be shortened. 4-93 4-2 Function Mode Multi-function Pulse Counter (PCNT, PCC) •The Inverter can input pulse trains via a multi-function input. •With pulse counter monitor d028, you can monitor the total count of input pulses. Parameter No. Function name C001 to C008 Multi-function inputs 1 to 8 selection Data 74: PCNT (pulse counter) 75: PCC (pulse counter clear) Related functions Default setting Unit   d028 Frequency resolution (Hz) = 250/(Input terminal response time set values C160 to C168 + 1 Example: When the input terminal response time = 1, the frequency resolution = 125 Hz. Input terminal response time Input pulse PCNT ON OFF Counter value 1 2 3 4 4-94 4 Functions •The total pulse count value cannot be stored. After the power is turned on or after reset, the counter is reset to zero. •Turning on PCC (pulse counter clear) clears the total count value. •The input pulse frequency resolution can be obtained with the following formula. (This applies to pulse input with a 50% duty ratio.) The Inverter cannot input frequency higher than the specified frequency resolution. It is recommended that you use input frequencies up to 100 Hz. For details on input terminal response, refer to "Input Terminal Response Time" (page 4-108). 4-2 Function Mode Multi-function Output Terminal Selection •You can allocate the following functions to any of multi-function output terminals 11 to 15 (C021 to C025) or the alarm relay output terminal (C026). •Multi-function output terminals 11 to 15 provide open-collector output. The alarm relay output terminal provides relay output. •You can select NO- or NC-contact output for each output terminal with C031 to C035, or C036. •If alarm code output is selected in C062 (refer to page 4-101), alarm code output (AC0 to AC3) is provided via output terminals 11 to 13 (for 3-bit code), or via output terminals 11 to 14 (for 4-bit code). The C021 to C025 settings are disabled. Data Functions 4 Description 00 RUN: Signal during RUN 01 FA1: Constant speed arrival signal 02 FA2: Over set frequency arrival signal 03 Reference item Page Signal during RUN 4-98 Frequency arrival signal 4-98 OL: Overload warning Overload limit/Overload warning 4-49 04 OD: Excessive PID deviation PID function 4-31 05 AL: Alarm output  06 FA3: Set-frequency-only arrival signal Frequency arrival signal 4-98 07 OTQ: Overtorque Overtorque 4-100 08 IP: Signal during momentary power interruption Momentary power interruption/Undervoltage 4-44 09 UV: Signal during undervoltage 10 TRQ: Torque limit Torque limit function 4-57 11 RNT: RUN time over RUN time over 4-52 12 ONT: Power ON time over Power ON time over 4-52 13 THM: Thermal warning Electronic thermal function 4-46 19 BRK: Brake release Brake control function 4-76 20 BER: Brake error 21 ZS: 0-Hz signal 0-Hz detection signal 4-101 22 DSE: Excessive speed deviation V2 control mode selection 4-124 23 POK: Position ready Orientation function 4-134 24 FA4: Set frequency exceeded 2 Frequency arrival signal 4-98 25 FA5: Set frequency only 2 26 OL2: Overload warning 2 Overload limit/Overload warning 4-49 27 ODc: Analog O disconnection detection 28 OIDc: Analog OI disconnection detection Window comparator function 4-66 29 O2Dc: Analog O2 disconnection detection 31 FBV: PID FB status output PID function 4-31 32 NDc: Network error Network error 4-104 4-95  4-2 Function Mode Data Description 33 LOG1: Logic operation output 1 34 LOG2: Logic operation output 2 35 LOG3: Logic operation output 3 36 LOG4: Logic operation output 4 37 LOG5: Logic operation output 5 38 LOG6: Logic operation output 6 39 Reference item Page 4-102 WAC: Capacitor life warning signal Capacitor life warning signal 4-103 40 WAF: Cooling fan life warning signal Cooling fan speed drop signal 4-104 41 FR: Starting contact signal Starting contact signal 4-105 42 OHF: Fin overheat warning Fin overheat warning 4-105 43 LOC: Light load detection signal Light load detection signal 4-106 44 MO1 (Drive programming output 1) 45 MO2 (Drive programming output 2) 46 MO3 (Drive programming output 3) Drive programming outputs  47 MO4 (Drive programming output 4) 48 MO5 (Drive programming output 5) 49 MO6 (Drive programming output 6) 50 IRDY: Operation ready signal Operation ready signal 4-106 51 FWR: Forward run signal Forward run signal 4-107 52 RVR: Reverse run signal Reverse run signal 4-107 53 MJA: Fatal fault signal Fatal fault signal 4-107 54 WCO: Window comparator O 55 WCOI: Window comparator OI Window comparator function 4-66 56 WCO2: Window comparator O2 63 OPO: Option board output  Output controlled from option board Related functions C021 to C025, C026 Multi-function Output Terminal Contact Selection •You can set NO- or NC-contact output individually for multi-function output terminals 11 to 15 as well as the relay output terminal. •Multi-function output terminals 11 to 15 provide open-collector output. Parameter No. Function name C031 to C035 Multi-function output terminal 11 to 15 contact selection C036 Relay output (AL2, AL1) contact selection Data Default setting Unit 00: NO 01: NC 00  00: NO contact between AL2, NC contact at AL1 01: NC contact between AL2, NO contact at AL1 01  4-96 4 Functions Logic operation function 4-2 Function Mode Specifications of Multi-function Output Terminals 11 to 15 •Below are the specifications of multi-function output terminals 11 to 15. 15 Inside the Inverter C031 to C035 set values 11 CM2 Power supply Output status Electrical characteristics ON 4 00 (NO contact) OFF  OFF Functions Between each terminal and CM2 Voltage drop 4 V max. at power-on Max. allowable voltage: 27 V DC Max. allowable current: 50 mA ON ON 01 (NC contact) ON OFF  OFF Specifications of the Relay Output Terminals •The relay output terminals have an SPDT contact configuration. Below is its operation. AL0 AL2 AL1 Inside the Inverter (Default value: C036 = 01) (Example) When the relay output terminals are used for alarm C036 set values Output terminal status Power Inverter status AL2AL0 Resistance load AL1AL0 AL2AL0 Max. contact capacity Abnormal Closed Open Min. contact capacity Normal Open Closed Max. contact capacity Inductive load 250 V AC, 2 A 30 V DC, 8 A 250 V AC, 0.2 A 30 V DC, 0.6 A 100 V AC, 10 mA 5 V DC, 100 mA ON 00 AL1AL0 OFF 01 (Default) Open Closed Abnormal Open Closed Normal Closed Open  Open Closed ON OFF 4-97  Min. contact capacity 250 V AC, 1 A 30 V DC, 1 A 250 V AC, 0.2 A 30 V DC, 0.2 A 100 V AC, 10 mA 5 V DC, 100 mA 4-2 Function Mode Signal During RUN •While the Inverter is running, this signal is output via multi-function output terminals 11 to 15 or the relay output terminal. •Allocate "00" (RUN) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). •This signal is also output during DC injection braking. Below is the time chart. Output frequency FW 4 RUN Functions Frequency Arrival Signal •When the output frequency reaches the set level, a frequency arrival signal is output. Parameter No. Function name C042 Arrival frequency during acceleration C045 Arrival frequency during acceleration 2 C043 Arrival frequency during deceleration C046 Arrival frequency during deceleration 2 Data Default setting Unit 0.00: Does not output arrival signal during acceleration. 0.01 to 400.00: Outputs arrival signal during acceleration. 0.00 Hz 0.00: Does not output arrival signal during deceleration. 0.01 to 400.00: Outputs arrival signal during deceleration. 0.00 Hz •For elevating machines, use this signal for applying the brake. To release the brake, use the overtorque signal. •Allocate "01" (FA1: Constant speed arrival signal), "02" (FA2: Set frequency exceeded), "06" (FA3: Set frequency only), "24" (FA4: Set frequency exceeded 2), or "25" (FA5: Set frequency only 2) to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). •Below is the hysteresis of the frequency arrival signal: ON: (Set frequency - 1% of the maximum frequency) (Hz) OFF: (Set frequency - 2% of the maximum frequency) (Hz) If "06" (FA3) or "25" (FA5) is set, however, operation during acceleration is: ON: (Set frequency - 1% of the maximum frequency) (Hz) OFF: (Set frequency + 2% of the maximum frequency) (Hz) and operation during deceleration is: ON: (Set frequency + 1% of the maximum frequency) (Hz) OFF: (Set frequency - 2% of the maximum frequency) (Hz) 4-98 4-2 Function Mode Constant Speed Arrival Output (01: FA1) A signal is output when the output frequency has reached the level set in the frequency setting (F001, A020, A220, and A320) or multi-step speed (A021 to A035). Set frequency foff fon fon: 1% of the max. frequency foff: 2% of the max. frequency Output frequency (Example) Max. frequency fmax = 120 (Hz) Set frequency fset = 60 (Hz) fon = 120 × 0.01 = 1.2 (Hz) foff = 120 × 0.02 = 2.4 (Hz) During acceleration: ON at 60 - 1.2 = 58.8 (Hz) During deceleration: OFF at 60 - 2.4 = 57.6 (Hz) FA1 Functions 4 Set-frequency-exceeded Output (02: FA2, 24: FA4) A signal is output when the output frequency has exceeded the arrival frequencies during acceleration/deceleration set in [C042, C043 (FA2)] and [C045, C046 (FA4)]. C042/C045 fon Output frequency C043/C046 foff fon: 1% of the max. frequency foff: 2% of the max. frequency FA2/FA4 Set-frequency-only Output (06: FA3, 25: FA5) A signal is output when the output frequency equals the arrival frequencies during acceleration/ deceleration set in [C042, C043 (FA3)] and [C045, C046 (FA5)]. Output frequency C042/C045 fon FA3/FA5 4-99 foff fon C043/C046 foff fon: 1% of the max. frequency foff: 2% of the max. frequency 4-2 Function Mode Overtorque (OTQ) •This function outputs a signal when detecting a motor output torque estimated value exceeding a specified level. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data Default setting Unit  07: OTQ (Overtorque) C026 Relay output (AL2, AL1) function selection C055 Overtorque level (Forward power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) OTQ signal output level for forward power running 200 % 4 C056 Overtorque level (Reverse regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) OTQ signal output level for reverse regeneration 200 % C057 Overtorque level (Reverse power running) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) OTQ signal output level for reverse power running 200 % Functions C058 Overtorque level (Forward regeneration) 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) OTQ signal output level for forward regeneration 200 % Related functions 05 A044, A244, A344, C063 •Enabled when "overtorque signal" is selected in the multi-function output selection. You can use this function only when "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected in V/f characteristics selection A044/A244. With other settings, the output is unstable. •For elevating machines, use this signal for releasing the brake. To close the brake, use the frequency arrival signal. 4-100 4-2 Function Mode 0-Hz Detection Signal •This function outputs a detection signal when the Inverter's output frequency falls below the 0-Hz detection value set in 0-Hz detection level C063. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection C063 0-Hz detection level 4 Data Default setting Unit   21: ZS (0-Hz signal) 05 0.00 to 100.00: Set a frequency to be detected as 0 Hz. Related functions Hz 0.00 A044, A244, A344 Functions •Enabled when "21" (ZS) is allocated to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). When "VC", "special VP", "free V/F", "sensorless vector control", or "0-Hz sensorless vector control" is selected as the control method, this function works for the Inverter's output frequency. When the control method is "sensor vector control", this function works for the motor rotation frequency. Alarm Code Output (AC0 to AC3) •This function outputs a 3-bit or 4-bit code signal to indicate the cause of an Inverter trip. Parameter No. Function name Data Default setting Unit 00  00: OFF (Disabled) C062 Alarm code selection 01: 3-bit 02: 4-bit •If "01" (3-bit) or "02" (4-bit) is selected in alarm code selection C062, multi-function output terminals 11 to 13, or 11 to 14, are forced to output an alarm code. The following table shows the output alarm codes. Multi-function output terminals With 4-bit code selected With 3-bit code selected 14 13 12 11 AC3 AC2 AC1 AC0 0 0 0 0 0 0 0 1 0 0 1 0 E05, E38 Overload protection Overload protection in a low speed range 0 0 1 1 E07, E15 Overvoltage/Incoming overvoltage protection 0 1 0 0 E09 Undervoltage protection E09 Undervoltage protection 0 1 0 1 E16 Momentary power interruption protection E16 Momentary power interruption protection 0 1 1 0 E30 IGBT error E30 IGBT error 0 1 1 1 E06 Braking resistor overload protection Factor code 4-101 Normal Trip cause Normal E01 to E03, Overcurrent protection E04 Factor code Normal Trip cause Normal E01 to E03, Overcurrent protection E04 E05 E07, E15  Overload protection Overvoltage/Incoming overvoltage protection Other errors 4-2 Function Mode Multi-function output terminals 14 13 12 11 AC3 AC2 AC1 AC0 1 0 0 1 0 1 With 4-bit code selected With 3-bit code selected Factor code Trip cause Factor code Trip cause 0 E08, E11 E23, E25 EEPROM error, CPU error, GA communication error, Main circuit error   0 1 E10 CT error   0 1 0 E12, E13 E35, E36 External trip, USP error, Thermistor error, Brake error   1 1 0 0 E14 Grounding protection   1 1 0 1 E20 Abnormal temperature due to the cooling fin's speed drop 1 1 0 1 E21 Abnormal temperature   1 1 1 0 E24 Input phase loss protection   1 1 1 1 E50 to E79 Network error, Options 1, 2 Errors 0 to 9   4 Functions Output Signal Logic Operation •This function performs output signal logic operations inside the Inverter. •All output signals are operation targets. However, the logic operation outputs (LOG1 to LOG6) are not subject to operations. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data 33: LOG1 (Logic operation output [C142, C143, C144]) 34: LOG2 (Logic operation output 2 [C145, C146, C147]) 35: LOG3 (Logic operation output 3 [C148, C149, C150]) 36: LOG4 (Logic operation output 4 [C151, C152, C153]) 37: LOG5 (Logic operation output 5 [C154, C155, C156]) 38: LOG6 (Logic operation output 6 [C157, C158, C159]) Default setting Unit   C026 Relay output (AL2, AL1) function selection C142/C145/C148/ C151/C154/C157 Logic output signal selection 1 Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 1. 00  C143/C146/C149/ C152/C155/C158 Logic output signal selection 2 Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 2. 00  C144/C147/C150/ C153/C156/C159 Logic output signal operator selection 00: AND 01: OR 02: XOR 00  05 4-102 4-2 Function Mode •You can select from three types of operators (AND, OR, and XOR). Output signal 1 Output signal 2 LOGx (AND) LOGx (OR) LOGx (XOR) •The setting parameters vary depending on the logic operation output selected. Refer to the following table to set the necessary parameters. Functions 4 Selected signal Operand 1 selection Operand 2 selection Operator selection 33: Logic operation output 1 (LOG1) C142 C143 C144 34: Logic operation output 2 (LOG2) C145 C146 C147 35: Logic operation output 3 (LOG3) C148 C149 C150 36: Logic operation output 4 (LOG4) C151 C152 C153 37: Logic operation output 5 (LOG5) C154 C155 C156 38: Logic operation output 6 (LOG6) C157 C158 C159 (Example) To output a logic output 1 (LOG1) signal through AND operation of "RUN signal" (00: RUN) and "over set frequency arrival signal" (02: FA2) to multi-function output 2 •Multi-function input 2 selection (C002) : 33 (LOG1) •Logic output signal 1 selection 1 (C142) : 00 (RUN) •Logic output signal 1 selection 2 (C143) : 02 (FA2) •Logic output signal 1 operator selection (C144): 00 (AND) Capacitor Life Warning Signal •This function determines estimated service life of the capacitor on the PCB, based on the Inverter's internal temperature and ON time. •Life assessment monitor d022 shows the status of this signal. •If this function is activated, it is recommended that the main circuit board and logic board be replaced. Parameter No. C021 to C025 C026 4-103 Function name Data Multi-function output terminal 11 to 15 selection 39: WAC Relay output (AL2, AL1) (Capacitor life warning signal (on PCB)) function selection Default setting Unit   05 4-2 Function Mode Network Error •Enabled only when ModBus-RTU is selected for RS485 communication. •If a reception timeout error occurs, this signal is output until reception of the next data. •Set a time before reception timeout in communication error timeout C077. •For details, refer to "4-4 Communication Function". Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data Default setting   32: NDc (network error) C026 Relay output (AL2, AL1) function selection C077 Communication error timeout Unit 05 4 0.00 to 99.99: Set a time before reception timeout. 0.00 s Functions External controller Inverter Monitor timer Communication trip time (C077) Communication disconnection detection signal (NDc) Cooling Fan Speed Drop Signal •This signal is output when detecting that the Inverter's built-in cooling fan rotation speed is reduced to 75% or less. •If "01" is selected in cooling fan control b092, this signal is not output even while the fan is stopped. •While this signal is output, check the cooling fan for clogging. •Life assessment monitor d022 shows the status of this signal. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection Related functions Data Default setting Unit  40: WAF (cooling fan life warning signal)  05 b092, d022 4-104 4-2 Function Mode Starting Contact Signal •While the Inverter is receiving the RUN command, a starting contact signal is output. •The output is enabled regardless of the setting of RUN command source selection A002. •If inputs FW and RV are simultaneously turned on, the Inverter stops. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data Default setting Unit   41: FR (starting contact signal) Relay output (AL2, AL1) function selection C026 05 4 Forward command Functions Reverse command Starting contact signal (FR) Fin Overheat Warning •This function monitors the Inverter's internal fin temperature and outputs a signal when the temperature exceeds the fin overheat warning level (C064). Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection C064 Fin overheat warning level 4-105 Data Default setting Unit   42: OHF (fin overheat warning) 05 0 to 200: Set a temperature to output the overheat warning signal. 120 C 4-2 Function Mode Light Load Detection Signal •This signal is output when output current falls below the light load detection level (C039). •In light load signal output mode C038, you can set whether this output is enabled in any operation mode, or only in constant speed operation. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection Light load signal output mode C039 Light load detection level Default setting Unit   43: LOC (light load detection signal) 05 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) 0.0 to 2.00 × Rated current: (0.4 to 55 kW) 0.0 to 1.80 x Rated current (75 to 132 kW) Set an output level for low current signals. 4 01  Rated current A Output current (A) Low current signal detection level (C039) Low current signal Operation Ready Signal •This signal is output when the Inverter becomes ready for operation (ready to receive the RUN command). •Even if the RUN command is input while this signal is not output, the Inverter does not recognize the RUN command. •If this signal is not output, check if the input power supply voltage (R/L1, S/L2, T/L3) is within the specified range. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection Data Default setting Unit   50: IRDY (operation ready signal) 05 4-106 Functions C038 Data 4-2 Function Mode Forward Run Signal •This signal is output while the Inverter is running forward. •While the Inverter is running in reverse, or when stopped, this signal is turned off. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data Default setting   51: FWR (forward run signal) Relay output (AL2, AL1) function selection C026 Functions 4 Unit 05 Reverse Run Signal •This signal is output while the Inverter is running in reverse. •While the Inverter is running forward, or when stopped, this signal is turned off. Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection Data Default setting   52: RVR (reverse run signal) Relay output (AL2, AL1) function selection C026 Unit 05 Output frequency (kHz) Signal during forward operation Signal during reverse operation Fatal Fault Signal Parameter No. Function name C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection Data Default setting   53: MJA (fatal fault signal) 05 •In addition to an alarm, this signal is output if any of the following trips occurs. (These trips are caused by hardware.) 4-107 Unit No. Error code Description 1 E10.* CT error 2 E11.* CPU error 3 E14.* Grounding protection 4 E20.* Abnormal temperature due to cooling fan stop 5 E23.* Gate array communications error 6 E25.* Main circuit error 4-2 Function Mode Multi-function Output Terminal ON Delay/OFF Delay •You can set ON/OFF delay times for each output terminal. Output terminal ON delay time OFF delay time 11 C130 C131 12 C132 C133 13 C134 C135 14 C136 C137 15 C138 C139 RY (AL*) C140 C141 4 Function code Item C130/C132/C134/C136/ C138/C140 Output ON delay C131/C133/C135/C137/ C139/C141 Output OFF delay Data Default setting Unit 0.0 to 100.0: Set an ON delay time. 0.0 s 0.0 to 100.0: Set an OFF delay time. 0.0 s Input Terminal Response Time •You can set a sampling time individually for multi-function input terminals 1 to 8 as well as the FW terminal. This helps remove chattering or other noise. •If the terminal input becomes unstable because of chattering, increase the set value. The larger the data value is, the slower the response time. A setting range of 0 to 200 is available, which corresponds to approx. 2 to 400 ms. Parameter No. Function name C160 to C167 Input terminal response time 1 to 8 C168 FW terminal response time Data 0 to 200 (× 2 ms): Can be set in increments of 1. Default setting Unit 1 ms 4-108 Functions •All output signals immediately turn on/off when the specified conditions are satisfied. Depending on the selected signal, chattering may occur. In such a case, use this function to hold or delay the signal. •Set the parameters for individual output terminals (multi-function output terminals 11 to 15 and the relay output terminal: six terminals in total). For the output terminals and the corresponding parameters, refer to the table below. 4-2 Function Mode Digital FM Terminal •You can monitor the output frequency and current using the FM terminal on the control circuit terminal block. •The FM terminal provides pulse output. FM Selection •Select a signal to output from the following table. For "03" (digital output frequency), use the digital frequency counter. For other output signals, use the analog meter. Parameter No. Functions 4 Data Description Full-scale value 00 Output frequency (example 1) 0 to Max. frequency (Hz)*3 01 Output current (example 1) 0% to 200% 02 Output torque (example 1)*1 0% to 200% 03 Digital output frequency (example 2) 0 to Max. frequency (Hz) 04 Output voltage (example 1) 0% to 100% 05 Power (example 1) 0% to 200% 06 Thermal load rate (example 1) 0% to 100% 07 LAD frequency (example 1) 0 to Max. frequency (Hz) 08 Digital current monitor *2 09 Motor temperature 0C to 200C (0C output at 0C or lower) 10 Fin temperature 0C to 200C (0C output at 0C or lower) 12 Drive programming output (YA0) - 19 Option board 1 (OP1) - 20 Option board 2 (OP2) - C027 *1. This output is enabled only when "SLV", "0-Hz SLV", or "V2" is selected. (Refer to "Control Method (V/f Characteristics)" (page 4-21).) (Example 1) Set values: 00, 01, 02, 04, 05, 06, 07, 09, 10, 12 (Example 2) Set values: 03, 08 t t T T Cycle T: Constant (6.4 ms) Duty ratio t/T: Variable Cycle T: Variable Duty ratio t/T: Fixed to 1/2 *2. Digital current monitor • When the monitor displays the value set in digital current monitor reference value C030, 1440 Hz is output. Parameter No. C030 Function name Data Digital current monitor 0.2 × Rated current to 2.0 × Rated current: reference value Set a current value at 1440-Hz output. Default setting Unit Rated current A *3. In any other method the real output frequency of the inverter including compensations (different than d001 value) is displayed. 4-109 4-2 Function Mode FM Adjustment •Adjust the Inverter output gain according to the meter connected to the FM terminal. Parameter No. Function name C105 FM gain setting Data Default setting Unit 100 % 50 to 200: Set a gain for the FM monitor. Related functions C027, b081 Analog Output AM/AMI Terminals You can monitor the output frequency and current using the AM and AMI terminals on the control circuit terminal block. The AM terminal provides 0- to 10-V analog output. The AMI terminal provides 4- to 20-mA analog output. •Select a signal to output from the following table. Parameter No. Function name Data Default setting Unit 00  00: Output frequency (0 to Max. frequency (Hz)*3) 01: Output current (0% to 200%) 02: Output torque *1(0% to 200%) 04: Output voltage (0% to 100%) 05: Power (0% to 200%) 06: Thermal load rate (0% to 100%) 07: LAD frequency (0 to Max. frequency [Hz]) C028/C029 AM selection/ AMI selection 09: Motor temperature (0C to 200C) (0C output at 0C or lower) 10: Fin temperature (0C to 200C) (0C output at 0C or lower) 11: Output torque (signed) (AM output only. 0% to 200% *1 *2) 13: Drive programming output (YA1) (AM selection only) 14: Drive programming output (YA2) (AMI selection only) 19: Option board 1 (OP1) (AM selection only) 20: Option board 2 (OP2) (AM selection only) *1. This output is enabled only when "SLV", "0-Hz SLV", or "V2" is selected. (Refer to "Control Method (V/f Characteristics)" (page 4-21).) *2. Below are the specifications of the output torque (signed). AM output (V) AM gain setting (C106) = 100% 10 AM gain setting (C106) = 200% 5 0 AM bias setting (C109) = 50% 100 200 Torque (%) *3. In any other method the real output frequency of the inverter including compensations (different than d001 value) is displayed. 4-110 Functions AM/AMI Selection 4 4-2 Function Mode AM/AMI Adjustment •Adjust the Inverter output gain according to the meters connected to the AM and AMI terminals. Parameter No. Function name Data Default setting C106 AM gain setting 50 to 200: Set a gain for the AM monitor. C109 AM bias setting 0 to 100: Set an offset for the AM monitor. C107 AMI gain setting 50 to 200: Set a gain for the AMI monitor. 100 C110 AMI bias setting 0 to 100: Set an offset for the AMI monitor. 20 Unit 100 0 % 4 Note: The offset data is set in %. (Example) If AMI provides 4 to 20 mA output, the offset value is 20% (= 4/20). (Default value) Functions Operation Selection During Option Error If the built-in optional board causes an error, you can set whether the Inverter trips or continues to run regardless of the option error. Parameter No. Function name P001/P002 Operation selection at option error Data 00: Trip 01: RUN (Continues operation) Default setting Unit 00  Offline Auto-Tuning Function •This function enables measurement and automatic setting of the motor parameters required for "sensorless vector control", "0-Hz sensorless vector control", and "sensor vector control". •To perform "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" for a motor with unknown motor parameters, perform offline auto-tuning to determine the motor parameters. •To use the online auto-tuning function described later, be sure to perform offline auto-tuning in advance. •This function is applicable to 1st/2nd control, not to 3rd control. •For motor parameters, the Inverter inputs data on one phase of Y-connection at 50 Hz. Parameter No. Function name H001 Auto-tuning selection H002/H202 Data 00: OFF (Disabled) 01: ON (STOP) 02: ON (Rotation) 00: Standard motor parameter 01: Auto-tuning parameter Motor parameter selection 02: Auto-tuning parameter (Online auto-tuning enabled.) Unit 00  00  Factory default kW 4 Pole H003/H203 Motor capacity selection H004/H204 Motor pole number selection 2/4/6/8/10 H030/H230 Motor parameter R1 (auto-tuning data) 0.001 to 65.535 Depends on the motor capacity.  H031/H231 Motor parameter R2 (auto-tuning data) 0.001 to 65.535 Depends on the motor capacity.  4-111 0.20 to 160.00 Default setting 4-2 Function Mode Parameter No. Function name H032/H232 Motor parameter L (auto-tuning data) H033/H233 Default setting Unit 0.01 to 655.35 Depends on the motor capacity. mH Motor parameter IO (auto-tuning data) 0.01 to 655.35 Depends on the motor capacity. A H034/H234 Motor parameter J (auto-tuning data) 0.001 to 9999.000 Depends on the motor capacity. kgm2 A003 Base frequency 30 to Max. frequency 50 Hz A051 DC injection braking selection 00: OFF (Disabled) 01: ON (Enabled) 02: ON (FQ) (Frequency control [A052 set value]) 01  A082 AVR voltage selection Data 4 200/400  •Note the following before use: •Set base frequency A003 and AVR voltage selection A082 according to the specifications of the motor to be measured. •The motor parameters can be determined for motors with the maximum applicable capacity or one rank lower motor size. For motors with other capacities, correct constant data may not be obtained. (In some cases, auto-tuning may not be completed. In this case, pressing the STOP/ RESET key displays an error message.) •If DC injection braking selection A051 is set to "01" (enabled), the data cannot be measured correctly. Be sure to set to "00" (disabled). (The default setting is "00" (disabled).) •If "02" (auto-tuning with motor rotation) is selected in auto-tuning selection H001, note the following: •Make sure there is no problem even if the motor accelerates up to approx. 80% of the base frequency. •The motor is not driven by external equipment. •The brake is released. •During auto-tuning, the output torque is insufficient, which may cause an elevator system to slip and fall. To prevent this, remove the motor from the load machine, and perform the autotuning for the motor separately. (In this case, moment of inertia (J) is determined for the single motor. You should add a motor shaft conversion value of the load machine's moment of inertial to parameter J.) •With a machine (e.g. lift, ball screw) whose motor shaft rotation is limited, the machine may be damaged if the allowable rotation limit is exceeded. In this case, set H001 to "01" (autotuning without motor rotation). •With a motor whose no-load current is unknown, measure the current at 50 Hz in the "V/f setting" mode, and perform auto-tuning after setting the current value in H023/H223. •Even if "01" (auto-tuning without motor rotation) is selected in H001, the motor may slightly rotate. •To perform auto-tuning for one rank lower motor size, enable the overload limit function and set the overload limit level to 1.5 times the rated current of the motor. 4-112 Functions 200/215/220/230/240: Selectable for 200-V class 380/400/415/440/460/480: Selectable for 400-V class 4-2 Function Mode Operating Procedure (1) Set auto-tuning selection H001 to "01" or "02". (2) Turn on the RUN command. Turning on the RUN command starts automatic operation in the following sequence. (1) 1st AC excitation (Motor does not run.)  (2) 2nd AC excitation (Motor does not run.)  (3) 1st DC excitation (Motor does not run.)  (4) V/f operation (Motor accelerates up to 80% of the base frequency.)  (5) SLV operation (Motor accelerates up to x% of the base frequency.)  (6) 2nd DC excitation (Motor does not run.)  (7) The auto-tuning result is displayed. Functions 4 Note 1: When "auto-tuning without motor rotation" is selected (H001 = 01), steps (4) and (5) are not performed. Note 2: The rotation frequency in step (5) is defined as follows ("T" is whichever larger value of acceleration time or deceleration time in step (4)): When T  0  50 s, x = 40% When 50 s  T  100 s, x = 20% When 100 s  T, x = 10% Note 3: If a trip occurs during auto-tuning, the auto-tuning processing is forced to stop. (No error message appears. Trip display is given higher priority.) After removing the cause of a trip, perform the auto-tuning again. Note 4: If the auto-tuning is interrupted by STOP command input (by pressing the STOP key or by turning off the RUN command), the parameters for auto-tuning may remain in the Inverter. To perform the auto-tuning again, initialize the parameters, and then set each parameter again. (This also applies when you restart ordinary operation.) Note 5: If the offline auto-tuning is performed with "free V/f setting" selected as the control method, the Inverter displays an error message and stops processing. Note 6: Even if auto-tuning is completed normally, the Inverter cannot be operated with the tuning data. To do so, be sure to set motor parameter selection H002 to "01". Online Auto-Tuning Function •Online auto-tuning compensates for changes in motor parameters resulting from a motor temperature rise or other factor, thus ensuring stable operation. •This function is applicable to 1st/2nd control, not to 3rd control. Parameter No. H002/H202 Function name Motor parameter selection Data 00: Standard motor parameter 01: Auto-tuning parameter 02: Auto-tuning parameter (Online auto-tuning data enabled.) Default setting Unit 00  Note the following before use: •Be sure to perform the offline auto-tuning before the online auto-tuning. •This function calculates online auto-tuning data during offline auto-tuning. Even with a generalpurpose motor, perform offline auto-tuning once. •After the motor is stopped, online auto-tuning is performed for 5 seconds max. (For tuning R1 and R2, this function performs DC excitation once. The tuning result is not displayed.) If the RUN command is input during this period, priority is given to the RUN command, and the online autotuning is aborted. (The tuning result is not reflected.) 4-113 4-2 Function Mode •With "DC injection braking during stop" selected, online auto-tuning starts after DC injection braking is completed. •If FOC and SON are allocated to terminals, online auto-tuning is not performed. Operating Procedure (1) Set motor parameter selection H002 to "02" (online auto-tuning enabled). (Set auto-tuning selection H001 to "00" (disabled).) (2) Turn on the RUN command. (The Inverter automatically performs online auto-tuning during stop.) Secondary Resistance Compensation Function (Temperature Compensation) 4 Parameter No. Function name P025 Secondary resistance compensation enable/disable selection Data 00: OFF (Disabled) 01: ON (Enabled) Default setting Unit 00  4-114 Functions •This function compensates for speed fluctuations resulting from motor temperature changes, when "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control method. To use this function, set thermistor selection b098 to "02" (NTC). (With other thermistors and settings, the motor temperature cannot be detected correctly.) 4-2 Function Mode Motor Parameter Selection •Set this parameter according to your motor. •To use several motors with a single Inverter in the "VC", "special VP", or "free V/F setting" control mode, calculate the total capacity of the motors and select the closest value in the motor capacity selection. •When automatic torque boost is used, improper setting of this parameter may result in torque reduction or motor hunting. •The motor parameters for "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" can be selected from the following three types: •Motor parameter of a standard motor •Motor parameter measured by offline auto-tuning •Arbitrarily set motor parameter •For 3rd control, motor parameters specified for 1st control are used. 4 Functions Parameter No. Function name Data Default setting Unit A044/A244/ A344 V/f characteristics selection 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) *1 03: SLV (Sensorless vector control) *1 04: 0SLV (0-Hz sensorless vector control) *1 05: V2 (Sensor vector control) *1 00  H002/H202 Motor parameter selection 00: Standard motor parameter 01: Auto-tuning parameter 02: Online auto-tuning parameter 00  H003/H203 Motor capacity selection Factory default kW H004/H204 Motor pole number selection 2/4/6/8/10 4 Pole H020/H220 Motor parameter R1 0.001 to 65.535 Depends on the motor capacity.  H021/H221 Motor parameter R2 0.001 to 65.535 Depends on the motor capacity.  H022/H222 Motor parameter L 0.01 to 655.35 Depends on the motor capacity. mH H023/H223 Motor parameter IO 0.01 to 655.35 Depends on the motor capacity. A H024/H224 Motor parameter J 0.001 to 9999.000 *2 Depends on the motor capacity. kgm2 H030/H230 Motor parameter R1 (auto-tuning data) 0.001 to 65.535 Depends on the motor capacity.  H031/H231 Motor parameter R2 (auto-tuning data) 0.001 to 65.535 Depends on the motor capacity.  H032/H232 Motor parameter L (auto-tuning data) 0.01 to 655.35 Depends on the motor capacity. mH H033/H233 Motor parameter IO (auto-tuning data) 0.01 to 655.35 Depends on the motor capacity. A H034/H234 Motor parameter J (auto-tuning data) 0.001 to 9999.000 *2 Depends on the motor capacity. kgm2 0.2 to 160.0 *1. For 1st control A044, all items (00 to 05) are selectable. However, for 2nd control A244 and 3rd control A344, the selectable range is 00 to 04, and 00 to 01, respectively. For ND the selectable range is 00 to 02. *2: Convert moment of inertia J into motor shaft data. The larger the J value, the faster the response, resulting in a steep torque rise; the smaller the J value, the slower the response, resulting in a gradual torque rise. After setting the J value, adjust the response speed in speed response H005/H205. 4-115 4-2 Function Mode Arbitrary Motor Parameter •For arbitrary settings of motor parameters, the function codes vary depending on the setting of 1st/ 2nd control and on the set value of the motor parameter selection. • When 1st/2nd control is enabled and the motor parameter selection is set to "00"  Directly enter H020 to H024. • When 1st/2nd control is enabled and the motor parameter selection is set to "01" or "02"  Directly enter H030 to H034. •If offline auto-tuning has not been performed, the motor parameters in the same capacity rank as the Inverter (standard motor parameters) are set in H030/H230 to H034/H234. Sensorless Vector Control •Note the following before use: •Sufficient characteristics may not be obtained if you select a motor size two or more ranks lower than the motor size specified. •If sensorless vector control cannot provide the desired characteristics, adjust the motor parameters depending on the phenomena, as shown in the table below. Operation status Power running Regeneration Phenomenon Adjusting method Adjustment item Speed change ratio is a negative value. Increase motor parameter R2 gradually (up to set parameter × 1.2). H021/H221/H031 Speed change ratio is a positive value. Reduce motor parameter R2 gradually (down to set parameter × 0.8). H021/H221/H031 Increase motor parameter R1 gradually (up to set parameter × 1.2). H020/H220/H030 Increase motor parameter Io gradually (up to set parameter × 1.2). H023/H223/H033 Reduce motor parameter J from the set parameter. H024/H224/H034 Insufficient torque at low frequency (several Hz) During startup Shock occurs during startup. During deceleration Motor hunting During torque limit Insufficient torque at low frequency during torque limit Set a overload limit level lower than that of the torque. Lowfrequency operation Rotation is not constant. Increase motor parameter J from the set parameter. Reduce the speed response. Reduce motor parameter J from the set parameter. H005/H205 H024/H224/H034 b021 b041 to b044 H024/H224/H034 A001, A044/A244, F001, b040, b041 to b044, H002/H202, H003/H203, Related functions H004/H204, H005/H205, H020/H220, H021/H221, H022/H222, H023/ H223, H024/H224, H050/H250, H051/H251, H052/H252 Note 1: Make sure that the carrier frequency (b083) is not lower than 2.1 kHz. If the carrier frequency is lower than 2.1 kHz, the Inverter does not operate normally. Note 2: To use lower rank motor size than the Inverter, set a torque limit value (b041 to b044), while keeping the value , calculated with the following formula, at 200% or lower. Otherwise, the motor may burn out.  = Torque limit set value × (Inverter capacity) / (Motor capacity) (Example) If the Inverter capacity is 0.75 kW and the motor capacity is 0.4 kW, the torque limit set value for  = 200%, calculated with the above formula, is as follows: Torque limit set value (b041 to b044) =  × (Motor capacity) / (Inverter capacity) = 200% x (0.4 kW)/(0.75 kW) = 106% 4-116 4 Functions •This function estimates and controls motor rpm and output torque based on the Inverter's output voltage and current, as well as the motor parameter settings. This control method provides high starting torque in a low-frequency range (0.3 Hz), enabling high-precision operation. •To use this function, set V/f characteristics selection A044/A244 to "03". •To use this function, make sure that the motor parameter settings are suitable for your motor. (Refer to "Motor Parameter Selection" (page 4-115)). 4-2 Function Mode 0-Hz Sensorless Vector Control •This function enables high-torque operation in the 0-Hz range (0- to 3-Hz frequency reference). This control method is particularly suitable for applications such as an elevating system, which requires sufficient torque in a low-frequency range at startup (e.g. crane, hoist). •To use this function, set V/f characteristics selection A044/A244 to "04". •To use this function, make sure that the motor parameter settings are suitable for your motor. (Refer to "Motor Parameter Selection" (page 4-115).) •The parameters for 0-Hz SLV control are as follows: •In 0-Hz limit H060/H260, you can set a current value used for constant current control in the 0Hz range (generally, 3.0 Hz or lower). This parameter is expressed as a ratio of the output current to the Inverter's rated current. •In 0-Hz SLV startup boost amount H061/H261, you can set a current boost amount at startup in the 0-Hz range. A current value expressed as a ratio to the Inverter's rated current is added to the current value set in H060/H260 at startup only. Functions 4 Parameter No. Function name H060/H260 Limit at 0 Hz H061/H261 Boost amount at SLV startup, 0 Hz Data Default setting Unit 100.0 % 50 % 0.0 to 100.0: Current limit in low frequency range 0 to 50: Current boost amount at startup •Note the following before use: •Select an Inverter with one rank higher in capacity than the motor's. •Sufficient characteristics may not be obtained if you select a motor size two or more ranks lower than the maximum applicable motor size. •In the 0-Hz sensorless control mode, the digital command board (3GAX-DI01) cannot be used. •If 0-Hz sensorless vector control cannot provide the desired characteristics, adjust the motor parameters depending on the phenomena, as shown in the table below. Operation status Power running Phenomenon Adjustment item Speed change ratio is a negative value. Increase motor parameter R2 gradually (up to set parameter × 1.2). H021/H221/H031 Speed change ratio is a positive value. Reduce motor parameter R2 gradually (down to set parameter × 0.8). H021/H221/H031 Increase motor parameter R1 gradually (up to set parameter × 1.2). H020/H220/H030 Increase motor parameter Io gradually (up to set parameter × 1.2). H023/H223/H033 Reduce motor parameter J from the set parameter. H024/H224/H034 Insufficient torque at low Regeneration frequency (several Hz) During startup Shock occurs during startup. During deceleration Motor hunting Immediately after deceleration Overcurrent or overvoltage protection is activated. Lowfrequency operation Rotation is not constant. Reduce the speed response. Related functions 4-117 Adjusting method H005/H205 Reduce motor parameter J from the set parameter. H024/H224/H034 Reduce motor parameter Io gradually (down to set parameter × 0.8). H023/H223/H033 Set AVR selection A081 to "00" (always ON) or "01" (always OFF). A081 Increase motor parameter J from the set parameter. H024/H224/H034 A001, A044/A244, F001, b040, b041 to b044, H002/H202, H003/H203, H004/H204, H005/H205, H020/H220, H021/H221, H022/H222, H023/ H223, H024/H224, H050/H250, H051/H251, H052/H252, H060/H260, H061/H261 4-2 Function Mode Note 1: Make sure that the carrier frequency (b083) is not lower than 2.1 kHz. If the carrier frequency is at 2.1 kHz or lower, the Inverter does not operate normally. Note 2: Set a torque limit value (b041 to b044), while keeping the value , calculated with the following formula, at 200% or lower. Otherwise, the motor may burn out.  = Torque limit set value × (Inverter capacity) / (Motor capacity) (Example) If the Inverter capacity is 0.75 kW and the motor capacity is 0.4 kW, the torque limit set value for  = 200%, calculated with the above formula, is as follows: Torque limit set value (b041 to b044) =  × (Motor capacity) / (Inverter capacity) = 200% × (0.4 kW)/(0.75 kW) = 106% Torque Monitor Function •This function allows you to monitor an estimated motor output torque, when "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control method. Function name Data Default setting Unit A044/A244 V/f characteristics selection 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00  C027 C028 C029 FM selection AM selection AMI selection 02: Output TRQ (Output torque) 11: Out TRQ sign (Output torque (signed)) (C028 only) 00  H003/H203 Motor capacity selection Factory default kW H004/H204 Motor pole number selection 4 Pole 0.20 to 160.0 2/4/6/8/10 •To use the monitor via the Digital Operator, select display code d012. •To use the monitor with a signal from the control terminal block, refer to "Digital FM Terminal" (page 4-109) or "Analog Output AM/AMI Terminals" (page 4-110). •If "VC", "special VP", or "free V/f setting" is selected in V/f characteristics selection A044/A244, this function is disabled, and the display or the output signal from the control terminal block is not defined. •For a torque monitor value of this function, the output torque at the rated frequency equivalent to the motor's output rating during synchronous rotation is indicated as 100%. •Since this function estimates output torque based on the motor current, the accuracy is approx. 20% when a motor with the same output capacity as the Inverter is used. 4-118 Functions Parameter No. 4 4-2 Function Mode Preliminary Excitation Function (FOC) •This function supplies excitation current from an input terminal to establish magnetic flux preliminarily, when "03" (sensorless vector control), "04" (0-Hz sensorless vector control), or "05" (sensor vector control) is selected in V/f characteristics selection A004/A244. •Allocate 55 (FOC) to the desired multi-function input. •The Inverter does not accept the RUN command unless the FOC terminal is turned on when FOC is allocated. •If the FOC terminal is turned off during operation, the Inverter goes into free-run status. If the FOC terminal is turned on again, the Inverter restarts according to the setting of free-run stop selection b088. 4 FOC Functions FW (RV) Does not operate because the FOC terminal is OFF. Output frequency Free running Restarts according to b088. Excitation current flows. Related functions A044/A244, C001 to C008 High-torque Multi-operation •When "sensorless vector control" or "0-Hz sensorless vector control" is selected with a single Inverter, this function controls two motors of the same type to drive a single load. •To use this function, you set the same parameters as when you select "Sensorless Vector Control" (page 4-116) or "0-Hz Sensorless Vector Control" (page 4-117). However, set the motor parameters as follows: •Set motor parameters R1, R2, and L to one half of the set value for one motor. •Set motor parameter Io to be twice the set value for one motor. •Set motor parameter J to one half of the total moment of inertia of two motors and loads connected to these motors. •Select the motor capacity value closest to the total capacity of two motors. •When different loads are driven with two motors, a fluctuation in one load affects the operating condition of the other, which may hinder normal control. To prevent this, be sure to operate a system in a way that the load driven by two motors is regarded as one load. Related functions 4-119 A044/A244, F001, b040, b041 to b044, H002/H202, H003/H203, H004/ H204, H005/H205, H020/H220, H021/H221, H022/H222, H023/H223, H024/H224, H050/H250, H051/H251, H052/H252 4-2 Function Mode Stabilization Parameter •This function adjusts to reduce motor hunting. •In case of motor hunting, check whether motor capacity H003/H203 and motor pole number selection H004/H204 match your motor. If they do not, match them. If the motor's primary resistance is smaller than that of the standard motor, increase the H006/H206/H306 set value gradually. To run a motor with a capacity larger than the Inverter's rated capacity, reduce the set value. •Other than this function, the following methods are suggested to reduce hunting: Lower the carrier frequency (b083). (Refer to page 4-68.) Lower the output voltage gain (A045). (Refer to page 4-24.) Parameter No. Function name Data Default setting Unit 100  Stabilization parameter A045 Output voltage gain 20 to 100: If hunting occurs, reduce the set value. 100 % b083 Carrier frequency 0.5 to 15.0: If hunting occurs, reduce the set value. 5.0 kHz Auto Return Initial Display •Ten minutes after last key operation display returns to the initial parameter set by b038. Parameter No. Function name b164 Auto return initial display Data 00: OFF (Disabled) 01: ON (Enabled) Default setting 00 Data Read/Write Selection •Restrict the data read/write operation by AX-OP05-E. Parameter No. Function name b166 Data read/write selection Data 00: R/W OK (Read/Write OK) 01: R/W Protected (Read/Write protected) Default setting 00 Option I/F cmd W Register 1 to 10 •When communication option board is used these parameters are used to define a user exchange area with the master unit. Refer to especific option board manual for details. Parameter No. Function name P160 to P169 Option I/F cmd W register 1 to 10 Data 0000 to FFFF Default setting 0000 4-120 4 Functions H006/H206/H306 0 to 255: If hunting occurs, adjust the set value. 4-2 Function Mode Option I/F cmd R Register 1 to 10 •When communication option board is used these parameters are used to define a user exchange area with the master unit. Refer to especific option board manual for details. 4 Parameter No. Function name P170 to P179 Option I/F cmd R register 1 to 10 Data 0000 to FFFF Default setting 0000 Profibus Communications Functions •Use these parameters to define the node address and communication type when 3G3AX-RX-PRT Profibus unit is used. Parameter No. Function name P180 Profibus node address P181 Profibus clear mode P182 Profibus map selection Data 0 to 125 Default setting - 00: Clear 01: Last value 00 00: PPO 01: Conventional 02: Flexible mode 00 CompoNet Communications •Use these parameters to configure CompoNet network when 3G3AX-RX-CRT CompoNet unit is used. Parameter No. Function name Data Default setting Operation setting at communications error 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free run 04: Decel-Stop (Deceleration stop) 00 Instance Number 0: Basic speed I/O 1: Extended speed I/O 2: Extended speed and Torque control 3: Special I/O 4: Extended control I/O 5: Extended control I/O and multifunction I/O monitor 6: Flexible format 7: Extended speed and Acceleration control 8-20: Not used 1 P048 Operation setting at idle mode detection 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) 00 P190 CompoNet node address 0 to 63 0 P045 P046 4-121 4-2 Function Mode DeviceNet Communications •Use these parameters to configure DeviceNet network when 3G3AX-RX-DRT unit is used. Parameter No. Function name P044 DeviceNet comm Watch dog timer Data 0.00 to 99.99 Default setting 1.00 Operation setting at communications error 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) Instance Number 0: Basic speed I/O 1: Extended speed I/O 2: Extended speed and Torque control 3: Special I/O 4: Extended control I/O 5: Extended control I/O and multifunction I/O monitor 6: Flexible format 7: Extended speed and Acceleration control 8-20: Not used 1 P048 Operation setting at idle mode detection 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) 00 P049 Polarity setting for rotation speed 0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/ 30/32/34/36/38 0 P192 DeviceNet node address 0 to 63 63 P045 4 Functions P046 00 MECHATROLINK-II Communications •Use these parameters to configure the MECHATROLINK-II network when 3G3AX-RX-MRT unit is used. Parameter No. Function name Data Default setting P195 ML2 frame length 00: 32 bytes 01: 17 bytes 00 P196 ML2 node address 21 to 3E 21 4-122 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Functions That Need 3G3AX-PG01 •Generally, the Feedback Option Board (3G3AX-PG01) is required for the following two cases: • "05" (V2: sensor vector control) is selected in V/f characteristics selection A044. • "Pulse train frequency input" is selected in any of the following parameters: •"06" (pulse train frequency) is selected in frequency reference selection A001. •With "10" (operation function result) selected in frequency reference selection A001, "07" (pulse train frequency) is selected in operation frequency input A setting (A141) or operation frequency input B setting (A142). •"03" (pulse train frequency) is selected in PID feedback selection A076. •When running the Inverter with V/f characteristics selection A044 set to "00" (VC), you can check the rotation direction with real frequency monitor d008. (If positive frequency is detected when the forward command is activated, or if negative frequency is detected when the reverse command is activated, the rotation direction is judged as being normal.) Functions 4 Related functions 4-123 A044, A001, A076, A141, A142 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used V2 Control Mode Selection Select a control method in V2 control mode selection P012. When "00" (ASR) is selected in P012, speed control mode is enabled. Select a frequency reference in frequency reference selection A001. When "01" (APR) is selected in P012, the Inverter enables position control by generating frequency reference based on the position command pulse input from the pulse train position command input terminal, and on the position feedback detected by the encoder. Select any of the three pulse train position command input modes in pulse train mode selection P013. To perform pulse train position control, allocate "48" (STAT) to any of the multi-function input terminals. While the STAT terminal is tuned on, pulse train position command input is accepted. Parameter No. Function name Data Default setting Unit 00  P012 V2 control mode selection 00: ASR (speed control mode) 01: APR (pulse train position control mode) 02: APR2 (absolute position control mode) 03: HAPR (high-resolution absolute position control mode) P011 Encoder pulses 128 to 65535: Number of encoder pulses 1024 Pulse P023 Position loop gain 0.00 to 100.00: Position loop gain 0.50 rad/s P027 Speed deviation error detection level 0.00 to 120.00: DSE signal output level 7.50 Hz H004 Motor pole number selection 2/4/6/8/10: Select the number of motor poles. 4 Pole C001 to C008 Multi-function inputs 1 to 8 selection 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission)   C021 to C025 Multi-function output terminals 11 to 15 selection C026 Relay output (AL2, AL1) function selection Related functions   22: DSE (excessive speed deviation) 05 A001, P013 4-124 Functions Position deviation can be cleared through external input. Allocate "47" (PCLR) to any of the multifunction input terminals. Tuning on and then off the PCLR terminal can clear position deviation data. Allocate "22" (DSE) to any of the multi-function output terminals to enable excessive speed deviation signal output. Set a deviation level in speed deviation error detection level P027. When the deviation between real frequency and reference frequency exceeds the P027 set value, the DSE signal turns on. When "02" (APR2) or "03" (HAPR) is selected in P012, the Inverter performs absolute position control with reference to the absolute position from its origin. 4 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Sensor Vector Control (Speed Control) To use this function, set V/f characteristics selection A044 to "05" (V2), and V2 control mode selection P012 to "00" (speed control). ("Sensor vector control" can be selected for 1st control only.) To use this function, make sure that the motor parameter settings are suitable for your motor. Refer to Inverter model RX user's manual "Chapter 4 Functions, 4-2 Function Mode, Motor Parameter Selection". Also, be sure to set the number of your encoder pulses. With V2 control mode selection P012, you can select four types of control modes: Speed control, Pulse train position control, Absolute position control, and High-resolution absolute position control. Note the following before use: • Sufficient characteristics may not be obtained if you select a motor size two or more ranks lower than the maximum applicable motor size. • If the Inverter does not normally accelerate, or if overload protection is activated, check the phase order of the encoder signal. (If phase A is advanced by 90 from phase B during forward run, it is judged as being normal.) When running the Inverter with V/f characteristics selection A044 set to "00" (VC), you can check the rotation direction with real frequency monitor d008. (If positive frequency is detected when the forward command is activated, or if negative frequency is detected when the reverse command is activated, the rotation direction is judged as being normal.) If sensor vector control cannot provide the desired characteristics, adjust the motor parameters depending on the phenomena, as shown in the table below. Functions 4 Operation status Phenomenon Adjusting method Adjustment item During startup Shock occurs during startup. Reduce motor parameter J from the set parameter. H024/H034 During deceleration Motor hunting During torque limit Insufficient torque at low frequency during torque limit Low-frequency operation Reduce the speed response. Reduce motor parameter J from the set parameter. Set a overload limit level lower than that of the torque. Rotation is not constant. Increase motor parameter J from the set parameter. Related functions H005 H024/H034 b021 b041 to b044 H024/H034 A001, A044, F001, b040 , H002, H003, H004 , H020 , H021 , H022 , H023 , H050 , H051 , H052 , P011, P012 Note 1: Make sure that the carrier frequency (b083) is not lower than 2.1 kHz. If the carrier frequency is at 2.1 kHz or lower, the Inverter does not operate normally. Note 2: To use a lower rank motor size than the Inverter, set a torque limit value (b041 to b044), while keeping the value , calculated with the following formula, at 200% or lower. Otherwise, the motor may burn out.  = Torque limit set value × (Inverter capacity) / (Motor capacity) (Example) If the Inverter capacity is 0.75 kW and the motor capacity is 0.4 kW, the torque limit set value for  = 200%, calculated with the above formula, is as follows: Torque limit set value (b041 to b044) =  × (Motor capacity) / (Inverter capacity) = 200% × (0.4 kW)/(0.75 kW) = 106% 4-125 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Torque Bias Function This function applies bias to the torque reference generated by speed control, and is useful for elevating applications (e.g. elevator). Parameter No. Function name Data Default setting Unit 00  P036 Torque bias mode 00: OFF (Disabled) 01: OPE (Digital Operator) 02: O2 (Terminal O2) *1 05: Option 1 06: Option 2 P037 Torque bias value -200 to 200 (0.4 to 55 kW) -180 to 180 (75 to 132 kW) Enabled when P036 = 01 0 % P038 Torque bias polarity selection *2 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00  d010 *1. When torque bias is set to the O2 terminal, -10 to +10 (V) is recognized as -200 to +200 (%). *2. • When "00" (As per sign) is selected: When the polarity of a torque bias signal is (+), the torque increases for forward rotation, and when it is (-), the torque increases for reverse rotation, regardless of the RUN direction. • When "01" (Depends on the RUN direction) is selected: The torque bias signal polarity and torque bias direction vary depending on the RUN command direction. Forward command: Applies torque in the same direction as the torque bias. Reverse command: Applies torque in the opposite direction of the torque bias. Torque Control Under this function, the Inverter can be used in torque control, as well as in the speed and pulse train position controls. Torque control can be applied to winders, and more. To run the Inverter in torque control mode, allocate "52" (ATR) to any of the multi-function inputs. While the ATR terminal is turned on, the torque reference input is enabled. In torque reference input selection P033, you can select one of the three analog inputs or the input via the Digital Operator. The torque control speed depends on the balance between torque and load. To prevent the Inverter from running out of control, set a speed limit value in P039 (forward) or P040 (reverse). Parameter No. Function name Data Default setting Unit 00: O (Terminal O) 01: OI (Terminal OI) 02: O2 (Terminal O2) 03: OPE (Digital Operator) 06: Option 1 07: Option 2 00  P033 Torque reference input selection P034 Torque reference setting 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) Torque reference when P033 = 03 0 % P035 Polarity selection at torque reference via O2 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00 - 4-126 Functions Related functions 4 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Functions 4 Parameter No. Function name P039 Speed limit value in torque control (forward) P040 Speed limit value in torque control (reverse) Data Default setting Unit 0.00 to Maximum frequency 0.00 Hz 0.00 to Maximum frequency 0.00 Hz 00  P036 Torque bias mode 00: OFF (None) 01: OPE (Digital Operator) 02: O2 (Terminal O2) 05: Option 1 06: Option 2 P037 Torque bias value -200 to +200 (0.4 to 55 kW) -180 to +180 (75 to 132 kW) Enabled when P036 = 01 0 % P038 Torque bias polarity selection 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00  C001 to C008 Multi-function inputs 1 to 8 selection 52: ATR (torque command input permission)   Related functions d009, d010, d012 Control Block Diagram Torque bias Torque limit ATR terminal Torque reference (Reference value for current control) Torque reference input Speed control (P control) Speed monitor Speed limit value The speed control (P control) operates when a speed detection value exceeds the limit value. Speed detection value Pulse Train Position Control Mode To use this function, set V/f characteristics selection A044 to "05" (V2), and V2 control mode selection P012 to "01" (pulse train position control). ("Sensor vector control" can be selected for 1st control only.) Select a pulse train position command input mode in pulse train mode selection P013. Parameter No. Function name Data P012 V2 control mode selection 01: APR (pulse train position control mode) P013 00: Mode 1 (pulse train with 90 phase difference) 01: Mode 2 (forward/reverse command + Pulse train mode selection pulse train) 02: Mode 3 (forward pulse train + reverse pulse train) 4-127 Default setting Unit 00  4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Parameter No. Function name P017 Position ready range setting P018 Position ready delay time setting P019 Electronic gear setting position selection P020 Data Unit 5  0.00 s 00: FB (Position feedback side) 01: REF (Position command side) 00  Electronic gear ratio numerator 1 to 9999 1  P021 Electronic gear ratio denominator 1 to 9999 1  P022 Position control feedforward gain 0.00 to 655.35 0.00  P023 Position loop gain 0.00 to 100.00 0.50 rad/s P024 Position bias amount -2048 to 2048 0 rad/s C001 to C008 Multi-function inputs 1 to 8 selection 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission)   0 to 10000: Set a value equivalent to encoder ×4 multiplication. 0.00 to 9.99 Frequency reference for the pulse train position control mode is calculated with the following formula: P 6.4 × P × Kv Frequency reference (Hz) = ENC × 255 P Kv ENC P : Number of motor poles : Position loop gain : Number of encoder pulses : Position deviation In the position control mode, the acceleration/deceleration time settings are disabled. (The Inverter is automatically brought into LAD cancel status.) The higher the position loop-back gain, the shorter the acceleration/deceleration time. For details on the pulse train input mode, refer to the following. •Mode 0: Pulse train with 90 phase difference SAP SAN (Pulse train input) SBP SBN (Pulse train input) Detected pulses Forward Reverse Time 4-128 4 Functions Default setting 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used •Mode 1: Forward/Reverse command + Pulse train SAP SAN (Pulse train input) SBP SBN (Forward/Reverse command) Detected pulses Forward Reverse 4 Time •Mode 2: Forward pulse train + Reverse pulse train Functions SAP SAN (Forward pulse train input) SBP SBN (Reverse pulse train input) Detected pulses Forward Reverse Time Electronic Gear Function This function allows you to set a gain relative to position command or position feedback and to change the main/sub motor rotation ratio, particularly for synchronous operation. Parameter No. Function name P019 Electronic gear setting position selection P020 Default setting Unit 00: FB (Position feedback side) 01: REF (Position command side) 00  Electronic gear ratio numerator *3 1 to 9999 1  P021 Electronic gear ratio denominator *3 1 to 9999 1  P022 Position control feedforward gain *1 0.00 to 655.35 0.00  P023 Position loop gain *2 0.00 to 100.00 0.50 rad/s 4-129 Data 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Note: Below are the block diagrams of the electronic gear function. First-order lag filter Position control feedforward gain 1 P022 1+sT Position loop gain P019 = 00 (FB) Position command Speed command P023 N D Electronic gear Position feedback 4 P019 = 01 (REF) Electronic gear Position N command D Functions First-order lag filter Position control feedforward gain 1 P022 1+sT Position loop gain Speed command P023 Position feedback *1. It is recommended that position control feedfoward gain adjustment should be started with P022 = 2.00. To reduce the position deviation between the main and sub motors, increase the feedforward gain. If motor hunting occurs, reduce the feedforward gain. *2. It is recommended that position loop gain adjustment should be started with P023 = 2.00. To increase positioning accuracy and holding power, increase the position loop gain. If an increased position loop gain causes hunting, reduce the position loop gain. *3. Make sure that the N/D setting is within the range of 1/50  N/D  20. (N: Electronic gear ratio numerator [P020], D: Electronic gear ratio denominator [P021]) Example: Synchronous Operation Master Inverter Slave Inverter AP, BP AN, BN EG5 SAP, SBP SAN, SBN EG5 EAP, EBP EAN, EBN Main motor M EC EAP, EBP EAN, EBN Sub motor M EC For the Inverter (master Inverter) on the main motor side, you can select either the speed control or pulse train position control mode. For the Inverter (slave Inverter) on the sub motor side, you need to select the pulse train position control mode. 4-130 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Configuration Example •Main motor : Number of encoder pulses = 1024 •Sub motor : Number of encoder pulses = 3000 •Main motor rpm:Sub motor rpm = 2:1 For operation under the above conditions, set the following data in the slave Inverter. Pulse train mode selection (P013) Electronic gear setting position selection (P019) Electronic gear ratio numerator (P020) Electronic gear ratio denominator (P021) The following shows an example of the ratio of slave rpm to master rpm depending on the P019 to P021 settings. (Note that the same number of encoder pulses (1024 pulses) should be set on both Inverters.) 4 Functions : 00 (pulse with 90 phase difference) : 01 (REF) : 3000 : 1024 × 2 = 2048 Electronic gear setting position selection (P019) REF (Position command side) REF (Position command side) FB (Position feedback side) FB (Position feedback side) Electronic gear ratio numerator (P020) 1024 2048 1024 2048 Electronic gear ratio denominator (P021) 2048 1024 2048 1024 Slave rpm/Master rpm 1/2 2 2 1/2 Configuration Example •Main motor : Number of encoder pulses = 1024 •Sub motor : Number of encoder pulses = 3000 •Main motor rpm:Sub motor rpm = 2:1 For operation under the above conditions, set the following data in the slave Inverter. Electronic gear setting position selection (P019) : 01 (REF) Electronic gear ratio numerator (P020) : 3000 Electronic gear ratio denominator (P021) : 1024 × 2 = 2048 FFWG Position control feedforward gain + REF + G - + Position loop gain N D FB Electronic gear setting position =00(FB) selected 4-131 ASR 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used FFWG Position control feedforward gain REF N D + + G - + ASR Position loop gain 4 FB Functions Electronic gear setting position =01(REF) selected 4-132 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Motor Gear Ratio Setting Function This function is useful for a system with an optional encoder installed on the machine side. Set the number of actual encoder pulses in encoder pulses P011. Set a motor-to-encoder rpm ratio in motor gear ratio numerator/denominator P028/P029. With the above settings, the number of encoder pulses converted into motor shaft data is set in the Inverter. This function performs speed/position detection based on the number of encoder pulses converted into motor shaft data and calculates the orientation stop position based on the number of encoder pulses (P011). Functions 4 Parameter No. Function name P028 Motor gear ratio numerator P029 Motor gear ratio denominator P011 Encoder pulses Data 1 to 9999 Set a motor-to-encoder rpm ratio. 128 to 65535 Set the number of actual encoder pulses. Default setting Unit 1  1024 Pulse Note: Make sure that the N/D setting is within the range of 1/50  N/D  20. (N: Motor gear ratio numerator, D: Motor gear ratio denominator) Encoder (1024 pulses) Gear/Load (1:10) Motor •When the motor-to-encoder rpm ratio is 1:10, set the following data: Number of encoder pulses (P011) : 1024 Motor gear ratio numerator (P028) : 10 Motor gear ratio denominator (P029) : 100 In this case, the orientation stop position is defined as 4096 divisions of the encoder's one rotation. Note that the concept of the stop position is inverted from the description in "Orientation stop position conceptual drawing" (page 4-135). Position Bias Function Set this function to apply position command bias in the pulse train position control mode. The set number of pulses is added to a change value at 2-ms internals. This is used for adjusting the phase of synchronization points during synchronous operation. Set an addition value in position bias amount P024. A positive value adds the value in the forward direction. Related functions 4-133 P024 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Speed Bias Function This function applies speed command bias in the pulse train position control mode. Set a bias value in frequency addition amount A145, and select a sign in frequency addition direction A146. Allocate 50 (ADD) to any of the multi-function inputs. While the ADD terminal is turned on, the bias value is added to the speed command. Speed bias A145 4 Position bias ADD terminal P024 Set with A146. +/Position control Functions Position command variation Speed control Speed feedback value Position feedback variation Related functions A145, A146 Orientation Function This function determines a motor position at a single desired point during one rotation of the motor, and can be used to exchange tools for the machine tool main spindle or others. During positioning, the Z-pulse (one rotation position signal) is used as the reference signal. Input Z-pulse between EZP and EZN. Parameter No. Function name P011 Encoder pulses P014 Orientation stop position 0 to 4095 P015 Orientation speed setting Setting frequency to Max. frequency (upper limit: 120.0) P016 Orientation direction setting P017 Position ready range setting 0 to 10000 P018 Position ready delay time setting P023 Position loop gain C001 to C008 Multi-function inputs 1 to 8 selection C021 to C025 Multi-function output terminal 11 to 15 selection C026 Relay output (AL2, AL1) function selection Data 128 to 65535 (10000 to 65530) 00: FWD (Forward side) 01: REV (Reverse side) Default setting Unit 1024 Pulse 0  5.00 Hz 00 5 Pulse 0.00 to 9.99 0.00 s 0.00 to 100.00 0.50 rad/s 45: ORT (orientation)    23: POK (position ready) 05 4-134 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used RUN commands (FW/RV) ON ON ORT terminal Output frequency (2) (1) Orientation speed setting (P015) (3) Position ready range setting (P017) 4 Z pulse Functions POK signal ON (4) Position ready delay time setting (P018) Speed control Position control (1) When the RUN command is turned on with the ORT terminal turned on, the Inverter accelerates to the orientation speed (P015), and then performs constant speed operation. (If the RUN command is turned on during operation, the operation speed changes to the orientation speed when the ORT terminal is turned on.) (2) After the orientation speed is reached, the Inverter shifts to the position control mode when the first Z-pulse is detected. (3) During forward run, position control is performed with a target value of "Orientation stop position (P014) + one rotation"; During reverse run, with a target value of "Orientation stop position (P014) + two rotations". In this step, the higher the position loop gain (P023), the shorter the deceleration time (regardless of the deceleration time setting). (4) After the remaining number of pulses reaches the position ready range setting (P017), the Inverter outputs the POK signal after the position ready delay time setting (P018) elapses. (The POK output remains until the ORT signal is turned off.) After positioning is completed, the servo lock status remains until the RUN command is turned off. Note 1: Do not set a high frequency for the orientation speed, because positioning must be completed within two rotations during deceleration. Otherwise, overvoltage protection may cause a trip. Note 2: Orientation stop position is defined as 4096 (0 to 4095) divisions of one forward rotation from the reference point. (The number of divisions is fixed to 4096, regardless of the encoder's number of pulses.) The reference point is defined as the point where the pulse is input between EZP and EZN. Below is the layout of the stop target position. (Positive-phase connection) Motor shaft viewed from motor shaft load side Position of Z pulse Reference point 0 3072 1024 2048 Orientation stop position conceptual drawing 4-135 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Absolute Position Control Mode •To use this function, set V/f characteristics selection A044 to "05" (V2), and V2 control mode selection P012 to "02" (APR2: Absolute position control). •When "03" (high-resolution absolute position control) is selected in V2 control mode selection P012, control is based on ×4 the number of pulses used for internal operations. (Set the multi-step position command and position range setting for ×4 multiplication control.) •The position command can be changed up to 8 steps, depending on combinations of multi-function input terminals. •Zero return speed can be selected from one low speed and two high speeds. (The orientation function, described in the previous section, is not available.) •By using the teaching function, you can set the position command while running the machine. •By allocating "73" (SPD) to a multi-function input, you can switch between the speed and position controls. •For data with many digits (e.g. position command), only the higher 4 digits are displayed. Function name Data Default setting Unit P012 V2 control mode selection 00  P023 Position loop gain 0.00 to 100.00 0.50 rad/s P060 Multi-step position command 0 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P061 Multi-step position command 1 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P062 Multi-step position command 2 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P063 Multi-step position command 3 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P064 Multi-step position command 4 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P065 Multi-step position command 5 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P066 Multi-step position command 6 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P067 Multi-step position command 7 Position range setting (reverse side) to Position range setting (forward side) -268435455 to 268435455 0  P068 Zero return mode 00: Low speed 01: High speed 1 02: High speed 2 00  P069 Zero return direction selection 00: FWD (Forward side) 01: REV (Reverse side) 00  P070 Low-speed zero return frequency 0.00 to 10.00 0.00 Hz P071 High-speed zero return frequency 0.00 to Maximum frequency 0.00 Hz 02: APR2 (absolute position control mode) 03: HAPR (high-resolution absolute position control mode) 4-136 Functions Parameter No. 4 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Parameter No. Function name P072 Position range specification (forward) P073 Position range specification (reverse) Default setting Unit 0 to 268435455: When APR2 is selected 0 to 1073741823: When HAPR is selected 268435455  268435455 to 0: When APR2 is selected 1073741823 to 0: When HAPR is selected 268435455  00  P074 Teaching selection 00: X00 (Multi-step position command 0 (P060)) 01: X01 (Multi-step position command 1 (P061)) 02: X02 (Multi-step position command 2 (P062)) 03: X03 (Multi-step position command 3 (P063)) 04: X04 (Multi-step position command 4 (P064)) 05: X05 (Multi-step position command 5 (P065)) 06: X06 (Multi-step position command 6 (P066)) 07: X07 (Multi-step position command 7 (P067)) C169 Multi-step speed/position determination time 0 to 200: × 10 ms 0 ms d029 Position command monitor 1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected   d030 Current position monitor 1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected   45: ORT (orientation) 54: SON (servo ON) 66: CP1 (position command selection 1) 67: CP2 (position command selection 2) 68: CP3 (position command selection 3) 69: ORL (zero return limit signal) 70: ORG (zero return startup signal) 71: FOT (forward driving stop) 72: ROT (reverse driving stop) 73: SPD (speed/position switching)   03: Trip RESET (Trip reset only) 00  4 Functions Data C001 to C008 Multi-function inputs 1 to 8 selection C102 Reset selection 4-137 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Absolute Position Control Operation RUN command ON Output frequency (Hz) Speed command When the position command level is low, the motor decelerates and its position is determined before the output frequency reaches the speed command level. Position ready range setting (P017) 4 Position POK signal ON In the absolute position control mode, the Inverter moves to the target position according to the following parameter settings, and is then set in the position servo lock status. • Position command • Speed command (frequency reference) • Acceleration/Deceleration time (The servo lock status is retained until the RUN command is turned off.) The frequency reference and acceleration/deceleration command for absolute position control conform to the items selected when the RUN command is turned on. If the position command is set to a low value, the Inverter may stop deceleration and perform positioning before the speed command value is reached. In the absolute position control mode, the direction of RUN command (FW or RV) does not refer to the rotating direction. The FW or RV signal starts or stops the Inverter. The Inverter runs forward when "Target position - Current position" is a positive value, or runs in reverse when it is a negative value. If you do not perform zero return operation, (to be described later), the position at power-on is regarded as the origin (position = 0). When position command is set to "0", positioning is performed when the RUN command is turned on. In reset selection C102, select "03" (trip reset only). * If reset selection C102 is not set to "03", turning on the Inverter's reset terminal (or RESET key) clears the current position counter. To operate the Inverter by using the current position count value after resetting a trip by turning on the reset terminal (or RESET key), be sure to set reset selection C102 to "03". If PCLR is allocated, turning on the PCLR terminal clears the current position counter. (The internal position deviation counter is simultaneously cleared.) The absolute position control mode disables the ATR terminal. (Torque control is disabled.) The absolute position control mode disables the STAT terminal. (Pulse train position control is disabled.) The absolute position control mode disables the orientation function. (However, the ORT terminal is used for teaching, as described later.) 4-138 Functions Position ready delay time setting (P018) 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Multi-step Position Switching Function (CP1/CP2/CP3) By allocating "66" to "68" (CP1 to CP3) to any of multi-function inputs 1 to 8 (C001 to C008), you can select multi-step positions 0 to 7. Set position commands in multi-step position commands 0 to 7 (P060 to P067). If no position command is allocated to the terminals, multi-step position command 0 (P060) is defined as the position command. Functions 4 Position command CP3 CP2 CP1 Multi-step position 0 0 0 0 Multi-step position 1 0 0 1 Multi-step position 2 0 1 0 Multi-step position 3 0 1 1 Multi-step position 4 1 0 0 Multi-step position 5 1 0 1 Multi-step position 6 1 1 0 Multi-step position 7 1 1 1 When you input a multi-step position command, you can set the wait time until the terminal input is determined. This prevents the transition status from being applied before it is determined. You can adjust the determination time in multi-step speed/position determination time C169. If no input is made during the time set in C169, the data is determined after the set time elapses. (Note that the longer the determination time, the slower the input response.) Without determination time (C169) With determination time (C169) 7 3 Position command 5 4 1 CP1 CP2 CP3 Determination time (C169) 4-139 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Speed/Position Switching Function (SPD) Allocate 73 (SPD) to one of the multi-function inputs. While the SPD terminal is turned on, the current position counter is retained at "0". Therefore, if the SPD terminal is turned off during operation, the Inverter shifts to the position control mode. (Speed/ Position switching) At this time, if the position command is "0", the Inverter immediately stops. (Hunting may occur, depending on the position loop gain setting.) While the SPD terminal is turned on, the Inverter runs in the direction based on the RUN command. When shifting from speed control to position control, be careful about the polarity sign of the RUN command. 4 Output frequency Position count started Functions Speed control Position control Time Target position SPD terminal ON 4-140 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Zero Return Function This function performs three types of zero return operations depending on the setting of zero return mode P068. When zero return is complete, the current position is cleared to zero. You can select the zero return direction in zero return direction selection P069. If zero return is not performed, the Inverter performs position control with the position at power-on defined as the origin. ON ORG terminal 4 ON ORL terminal Functions Output frequency (2) Low-speed zero return frequency (P070) (3) (1) Origin Position ON ORG terminal ON ORL terminal (2) Output frequency High-speed zero return frequency (P071) (3) (1) Origin (5) Position (4) Low-speed zero return frequency (P070) ORG terminal ON ORL terminal ON (2) Output frequency High-speed zero return frequency (P071) (3) (1) (6) (5) Z pulse 4-141 (1) The Inverter accelerates to the lowspeed zero return frequency according to the acceleration time setting. (2) The Inverter runs at the low-speed zero return speed. (3) The Inverter performs positioning when the ORL signal is input. Low-speed zero return frequency (P070) (7) Origin Position (4) Low-speed zero return frequency (P071) (1) The Inverter accelerates to the highspeed zero return frequency according to the acceleration time setting. (2) The Inverter runs at the high-speed zero return frequency. (3) The Inverter starts deceleration when the ORL signal is turned on. (4) The Inverter runs in reverse at the low-speed zero return frequency. (5) The Inverter performs positioning when the ORL signal is turned off. (1) The Inverter accelerates to the highspeed zero return frequency according to the acceleration time setting. (2) The Inverter runs at the high-speed zero return frequency. (3) The Inverter starts deceleration when the ORL signal is turned on. (4) The Inverter runs in reverse at the low-speed zero return frequency. (5) The Inverter starts deceleration when the ORL signal is turned off. (6) The Inverter runs forward at the lowspeed zero return frequency. (7) The Inverter performs positioning at the first Z-pulse position after the ORL signal is turned on. 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Forward/Reverse Run Stop Function (FOT/ROT) With a signal from the control range limit switch, this function prevents the Inverter from running outside the specified operation range. The torque limit is set to 10% on the forward side when the FOT terminal is turned on, and on the reverse side when the ROT terminal is turned on. This function can be used as the limit switch at the machine end. To do so, allocate "71" (FOT) and "72" (ROT) to any of multi-function inputs 1 to 8 (C001 to C008). Position Range Setting Function Teaching Function This function starts or stops the motor at a desired position and stores the current position as a position command in a desired position command area. Allocate "45" (ORT) to any of multi-function inputs 1 to 8 (C001 to C008). When V2 control mode selection P012 is set to "02" (absolute position control) or "03" (high-resolution absolute position control), the relevant terminal serves as a teaching terminal. Related functions C001 to C008, P012, P074 (1) In teaching selection P074, select the position command you want to set. (2) Move the workpiece. • Input the RUN command with the ORT terminal turned on. At this time, the speed command and acceleration/deceleration time conform to the currently selected parameters. ORT terminal ON RUN command ON Output frequency Depends on the speed command selected. Position * If the Inverter control circuit (Ro, To) is turned on, teaching is enabled. The current position counter operates even if the workpiece is moved by an external device. Teaching is therefore enabled even while the Inverter is stopped. Note: Make sure that the power supplies (R/L1, S/L2, T/L3) for the Inverter power circuit are shut off or that the Inverter's outputs (U/T1, V/T2, W/T3) are disconnected from the motor. Not doing so may result in injury and/or damage to the equipment. (3) When the target position is reached, press the Enter key on the Digital Operator. Press the key on the data display screen (the PRG LED indicator is lit). 4-142 4 Functions Set a forward/reverse position control range in position range setting (forward) P072 and position range setting (reverse) P073. If the current position counter exceeds the setting range, a position control range trip (E63.* or E73.*) occurs, and the Inverter goes into free-run status. The upper limit setting of multi-step position commands 0 to 7 (P060 to P067) is limited by this control range setting. (You cannot set a position command beyond the position range.) 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used (4) The current position is set to the area corresponding to the position command source set in teaching selection P074. (However, the P074 setting is not stored. After the power is shut off or after reset, this parameter is indicated as "00" (x00).) Functions 4 P074 set values Position commands to be set 00 P060: Multi-step position command 0 01 P061: Multi-step position command 1 02 P062: Multi-step position command 2 03 P063: Multi-step position command 3 04 P064: Multi-step position command 4 05 P065: Multi-step position command 5 06 P066: Multi-step position command 6 07 P067: Multi-step position command 7 Servo ON Function This function brings the Inverter into speed servo lock status via an input terminal when "05" (sensor vector control) is selected in V/f characteristics selection A044. Allocate 54 (SON) to the desired multi-function input. The Inverter does not accept the RUN command unless the SON terminal is turned on when SON is allocated. If the SON terminal is turned off during operation, the Inverter goes into free-run status. When the SON terminal is turned on again, the Inverter restarts according to the setting of free-run stop selection b088. This function cannot be simultaneously used with the preliminary excitation function (55: FOC). If FOC and SON are both allocated to multi-function input terminals, priority is given to FOC, and SON is disabled. SON ON FW(RV) ON ON ON ON Does not operate because the SON terminal is OFF. Output frequency Free running Restarts according to b088. Speed servo-lock status Related functions 4-143 A044, C001 to C008 4-3 Functions When PG Option Board (3G3AX-PG01) Is Used Pulse Train Frequency Input This function allows you to use a pulse train input to the SAP-SAN terminals as frequency reference or PID feedback value in each control mode. (This function can be used in all control modes.) Set the input frequency at the maximum frequency in pulse train frequency scale P055. The analog input start/end function cannot be used. To limit the input frequency, use pulse train frequency bias amount P057 and pulse train frequency limit P058. Function name Data Default setting Unit P055 Pulse train frequency scale 1.0 to 50.0: Set the input frequency at the maximum frequency. 25.0 kHz P056 Pulse train frequency filter time constant 0.01 to 2.00: Set a filter time constant for pulse train input. 0.10 s P057 Pulse train frequency bias amount -100 to 100 0 % P058 Pulse train frequency limit 0 to 100 100 % A001 Frequency reference selection 06: Pulse train frequency 01 A076 PID feedback selection 03: Pulse (Pulse train frequency) 00 A141 Operation frequency input A setting 07: Pulse (Pulse train frequency) 02 A142 Operation frequency input B setting 07: Pulse (Pulse train frequency) 03  Pulse train frequency processing block Bias/Limit Limit Frequency measurement Hz % % 1 1+sT Hz Frequency reference Bias Frequency scale (P055) (1.0 to 50.0 kHz) First-order lag filter (P056) Maximum frequency (A004) Note: The SWENC switch on PG Board is available for "OFF: encoder disconnection detection disabled". 4-144 4 Functions Parameter No. 4-4 Communication Function 4-4 Communication Function •This function allows the Inverter to communicate with an external controller via the RS485 interface from the TM2 terminal on the Inverter's control terminal block board. Communication Specifications Item ModBus-RTU method Transmission speed 2400/4800/9600/19200 bps Communication method Half-duplex communication Synchronous system Asynchronous system ASCII code Binary Transmission code Transmission mode LSB first Compatible interface RS-485 Data bit length 7 or 8 bits Parity Select using the Digital Operator. 8 bits No parity/Even/Odd Select using the Digital Operator. 1 or 2 bits Select using the Digital Operator. Stop bit length Starting method Note Select using the Digital Operator. Start-stop synchronous system One-side start using host command Wait time 10 to 1000 [ms] Connection 0 to 1000 [ms] Overrun/Framing BCC/Vertical/Horizontal parity Error check Set using the Digital Operator. Use the Digital Operator to select a station No. 1:N (N = 32 max.) Overrun/Framing CRC-16/Horizontal parity For the RS485 communication function, use the TM2 terminal on the control terminal block board. Terminal abbreviations SN RP SN Control terminal block Control terminal block board SP Functions 4 ASCII method The following wires are recommended for TM2: 4-145 Description SP Transmission/Reception (+) SN Transmission/Reception (-) RP Termination resistor enabling terminal SN Termination resistor enabling terminal 4-4 Communication Function Stranded wire with solderless terminal 0.14 to 1.5 mm2 (If two equal-sized wires are connected to one pole: 0.14 to 0.5 mm2) 0.14 to 1.0 mm2 (If two equal-sized wires are connected to one pole: 0.14 to 0.2 mm2) 0.25 to 0.5 mm2 Wire strip length Tightening torque 5 mm 0.22 to 0.25 N•m (screw size: M2) Single wire Stranded wire External controller SP SN RP SN SP SN RP SN SP SN RP SN Setting RS485 communication requires the following settings. Parameter No. Function name C071 Communication speed selection (Baud rate selection) C072 Data Default setting Unit 02: Loop-back test 03: 2400 bps 04: 4800 bps 05: 9600 bps 06: 19200 bps 05  Communication station No. selection 1 to 247 1  C073 Communication bit length selection 7: 7-bit 8: 8-bit 8  C074 Communication parity selection 00: No parity 01: Even 02: Odd 00  C075 Communication stop bit selection 1: 1-bit 2: 2-bit 1  02  0.00 s C076 Communication error selection 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free-RUN (Free-run stop) 04: Decel-Stop (Deceleration stop) C077 Communication error timeout 0.00 to 99.99: Communication disconnection judgment time 4-146 4 Functions •Connection Connect the Inverters parallel to each other, as shown below. For the termination Inverter, shortcircuit the RP and SN terminals. (Also, if the RS485 communication function is used with a single Inverter, the RP and SN terminals must be short-circuited.) Short-circuiting the RP and SN terminals activates the termination resistor inside the control terminal block board, suppressing signal reflection. 4-4 Communication Function Parameter No. Function name Data Default setting Unit C078 Communication wait time 0 to 1000: Time to wait for response from the Inverter 0 ms C079 Communication method selection 00: ASCII 01: ModBus-RTU 01  Related functions A001, A002 Communication Test Mode •The communication test mode allows you to check the RS485 communication line (hardware). (Communication Test Mode Procedure) (1) Before conducting a loop-back test, disconnect the cable from TM2 on the control terminal block board. (2) Set the following parameter via the Digital Operator. •Set C071 (communication speed selection) to "02" (loop-back test). (3) Turn off the Inverter, and turn it on again. The check will start. (4) After the check is complete, the Digital Operator displays the following code: OK: LoopBack OK NG: LoopBack NG (5) Press the RESET button on the Digital Operator or on the copy unit to show the basic setting screen. Reset the parameter that you changed in step (2) to a desired setting. Functions 4 4-147 4-4 Communication Function ASCII Method Communication Procedure •The following shows the communication procedure between the Inverter and external controller. (1) External controller Inverter Time C078 (2) Wait time (Set via the Digital Operator.) 4 (1): Indicates a frame sent from the external controller to the Inverter. (2): Indicates a frame sent back from the Inverter to the external controller. Command List Command Description Communication with all stations 00 Inputs forward/reverse/stop command. Available 01 Sets frequency reference. Available 02 Sets multi-function input terminal status. Available 03 Reads all monitor data. Not available 04 Reads the Inverter status. Not available 05 Reads trip data. Not available 06 Reads a parameter. Not available 07 Sets a parameter. Available 08 Initializes each set value. Available 09 Checks if a set value can be stored in EEPROM. Not available 0A Stores a set value in EEPROM. Available 0B Re-calculates internal parameters. Available Note Enabled only when b084 is set to "01" or "02". (Clears trip data.) The following describes each command. 4-148 Functions Frame (2) is response output from the Inverter after reception of frame (1). It is not an active output. Below is each frame format (command). 4-4 Communication Function Inputs the forward/reverse/stop command. (To use this command, set A002 to "03" (RS485).) •Transmission frame Frame format STX Station No. Command Data Description STX Functions 4 BCC CR Data size 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32, and FF (Communication with all stations) Command Transmission command 2 bytes 00 Data Transmission data 1 byte * BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) CR Control code (Start of TeXt) Setting * Data Description 0 Stop command 1 Forward command 2 Reverse command Note (Example) To send a forward command to station 01 (STX) 01 00 1 (BCC) (CR) ASCII conversion 02 30 31 30 30 31 33 30 0D •Response frame Normal response: Refer to page 4-161. Error response: Refer to page 4-161. Sets frequency reference. (To use this command, set A001 to "03" (RS485).) •Transmission frame Frame format STX Station No. Command Data Description STX BCC Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32, and FF (Communication with all stations) Command Transmission command 2 bytes 01 Data Transmission data (Decimal ASCII code) 6 bytes * BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) CR * To set "5 Hz" for station 01 (STX) 01 01 000500 (BCC) (CR) ASCII conversion 02 30 31 30 31 30 30 30 35 30 30 30 35 0D 4-149 CR 4-4 Communication Function Note 1: Data is a value obtained by mulplying the set value by 100. (Example) 5 (Hz)  500  000500 ASCII conversion 30 30 30 35 30 30 Note 2: To use the data as PID control feedback data, set "1" in the MSB of the data. (Example) 5 (%)  500  100500 ASCII conversion 31 30 30 35 30 30 •Response frame Normal response: Refer to page 4-161. Error response: Refer to page 4-161. Sets multi-function input terminal status. 4 •Transmission frame Frame format Station No. Command Description STX Data BCC Data size CR Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32, and FF (Communication with all stations) Command Transmission command 2 bytes 02 Data Transmission data 16 bytes * BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) CR 4-150 Functions STX 4-4 Communication Function * Data (hexadecimal) and description of multi-function terminals (For details, refer to "Multi-function Input Selection" (page 4-79).) Data (hex) Functions 4 0000000000000001 0000000000000002 0000000000000004 0000000000000008 0000000000000010 0000000000000020 0000000000000040 0000000000000080 0000000000000100 0000000000000200 0000000000000400 0000000000000800 0000000000001000 0000000000002000 0000000000004000 0000000000008000 0000000000010000 0000000000020000 0000000000040000 0000000000080000 0000000000100000 0000000000200000 0000000000400000 0000000000800000 0000000001000000 0000000002000000 0000000004000000 0000000008000000 0000000010000000 0000000020000000 0000000040000000 0000000080000000 4-151 Description FWD RV CF1 CF2 CF3 CF4 JG DB SET 2CH : Forward : Reverse : Multi-step speed setting binary 1 : Multi-step speed setting binary 2 : Multi-step speed setting binary 3 : Multi-step speed setting binary 4 : Jogging : External DC injection braking : 2nd control : 2-step acceleration/deceleration FRS EXT USP CS SFT AT SET3 RS : Free-run stop : External trip : USP function : Commercial switching : Soft lock : Analog input switching : 3rd control : Reset STA STP F/R PID PIDC : 3-wire start : 3-wire stop : 3-wire forward/reverse : PID enabled/disabled : PID integral reset CAS UP DWN UDC : Control gain switching : UP/DWN function accelerated : UP/DWN function decelerated : UP/DWN function data clear OPE : Forced operator     Data (hex) 0000000100000000 0000000200000000 0000000400000000 0000000800000000 0000001000000000 0000002000000000 0000004000000000 0000008000000000 0000010000000000 0000020000000000 0000040000000000 0000080000000000 0000100000000000 0000200000000000 0000400000000000 0000800000000000 0001000000000000 0002000000000000 0004000000000000 0008000000000000 0010000000000000 0020000000000000 0040000000000000 0080000000000000 0100000000000000 0200000000000000 0400000000000000 0800000000000000 1000000000000000 2000000000000000 4000000000000000 8000000000000000 Description SF1 SF2 SF3 SF4 SF5 SF6 SF7 OLR TL TRQ1 TRQ2 PPI BOK ORT LAC PCLR STAT : Multi-step speed setting bit 1 : Multi-step speed setting bit 2 : Multi-step speed setting bit 3 : Multi-step speed setting bit 4 : Multi-step speed setting bit 5 : Multi-step speed setting bit 6 : Multi-step speed setting bit 7 : Overload limit switching : Torque limit enabled : Torque limit switching 1 : Torque limit switching 2 : P/PI switching : Brake confirmation : Orientation : LAD cancel : Position deviation clear : Pulse train position command permission ADD F-TM ATR KHC SON FOC MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 : Frequency addition : Forced terminal block : Torque command input permission : Integrated power clear : Servo ON : Preliminary excitation : Drive Programming input 1 : Drive Programming input 2 : Drive Programming input 3 : Drive Programming input 4 : Drive Programming input 5 : Drive Programming input 6 : Drive Programming input 7 : Drive Programming input 8  4-4 Communication Function * Data (hexadecimal) and description of multi-function terminals corresponding to 12 commands (For details, refer to "Multi-function Input Terminal Function".) Data (hex) Description Data (hex) Description  0000000100000000  0000000000000002 AHD: Analog command held 0000000200000000  0000000000000004 CP1: Position command selection 1 0000000400000000  0000000000000008 CP2: Position command selection 2 0000000800000000  0000000000000010 CP3: Position command selection 3 0000001000000000  0000000000000020 ORL: Zero return limit signal 0000002000000000  0000000000000040 ORG: Zero return startup signal 0000004000000000  0000000000000080 FOT: Forward driving stop 0000008000000000  0000000000000100 ROT: Reverse driving stop 0000010000000000  0000000000000200 SPD: Speed/Position switching 0000020000000000  0000000000000400 PCNT: Pulse counter 0000040000000000  0000000000000800 PCC: Pulse counter clear 0000080000000000  0000000000001000  0000100000000000  0000000000002000  0000200000000000  0000000000004000  0000400000000000  0000000000008000  0000800000000000  0000000000010000  0001000000000000  0000000000020000  0002000000000000  0000000000040000  0004000000000000  0000000000080000  0008000000000000  0000000000100000  0010000000000000  0000000000200000  0020000000000000  0000000000400000  0040000000000000  0000000000800000  0080000000000000  0000000001000000  0100000000000000  0000000002000000  0200000000000000  0000000004000000  0400000000000000  0000000008000000  0800000000000000  0000000010000000  1000000000000000  0000000020000000  2000000000000000  0000000040000000  4000000000000000  0000000080000000  8000000000000000  4 Functions 0000000000000001 (Example) To enable "Forward", "Multi-step speed 1", and "Multi-step speed 2" for the Inverter with station No. 01 0x0000000000000001 + 0x0000000000000004 + 0x0000000000000008 = 0x000000000000000D The transmission frame is therefore: (STX) 01 02 000000000000000D (BCC) (CR) 4-152 4-4 Communication Function •Response frame Positive response: Refer to page 4-161. Negative response: Refer to page 4-161. Reads all monitor data. •Transmission frame Frame format STX Station No. Command BCC Description 4 Functions STX CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 03 Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR •Response frame Frame format STX Station No. Data BCC Description STX Station No. Data size Setting Control code (Start of Text) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 Data Data BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) CR 4-153 CR 104 bytes * 4-4 Communication Function * Each monitor value Monitor item Magnification Data size Output frequency Hz × 100 8 bytes Decimal ASCII code Output current A × 10 8 bytes Decimal ASCII code Rotation direction   8 bytes 0: Stop, 1: Forward, 2: Reverse PID feedback monitor % × 100 8 bytes Decimal ASCII code Multi-function input monitor   8 bytes See *1 . Multi-function output monitor   8 bytes See *2 . Frequency conversion monitor  × 100 8 bytes Decimal ASCII code Output torque % ×1 8 bytes Decimal ASCII code Output voltage monitor V × 10 8 bytes Decimal ASCII code Power monitor kW × 10 8 bytes Decimal ASCII code    8 bytes "00000000" is stored. (Preliminary data storage area) RUN time monitor h ×1 8 bytes Decimal ASCII code ON time monitor h ×1 8 bytes Decimal ASCII code *1. Multi-function input terminal monitor Description  MSB LSB  *2. Multi-function output terminal monitor Item Data Item Data 1 terminal 00000001 11 terminal 00000001 2 terminal 00000002 12 terminal 00000002 3 terminal 00000004 13 terminal 00000004 4 terminal 00000008 14 terminal 00000008 5 terminal 00000010 15 terminal 00000010 6 terminal 00000020 Relay terminal 00000020 7 terminal 00000040 8 terminal 00000080 FW terminal 00000100 4-154 4 Functions Unit 4-4 Communication Function Reads the Inverter status. •Transmission frame Frame format STX Station No. Command BCC CR Description STX Data size Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 04 Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) 4 BCC CR Functions Setting •Response frame Frame format STX Station No. Data BCC CR Description STX Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 Data Data 8 bytes * BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) Station No. CR * Inverter status data includes the following three elements (A, B, and C). Data Status A Status B Status C Inverter status A 00 (Reserved) Inverter status B Inverter status C Code Status Code Status Code Status 00 Initial status 00 During stop 00 - 01 - 01 During RUN 01 Stop 02 During stop 02 During trip 02 Deceleration 03 During RUN 03 Constant speed 04 During FRS 04 Acceleration 05 During JG 05 Forward 06 During DB 06 Reverse 07 During retry 07 Forward to reverse 08 During trip 08 Reverse to forward 09 During UV 09 Forward run start 10 Reverse run start 4-155 4-4 Communication Function Reads trip data. •Transmission frame Frame format STX Station No. Command BCC Description STX CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 05 Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR 4 Functions 4-156 4-4 Communication Function •Response frame Frame format STX Station No. Data BCC Description STX CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Data Each monitor's data at the time of tripping 440 bytes BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) 4 CR * Functions * Each trip monitor stores the past six trips, together with total trip count (8 bytes). Total count Trip data 1 Monitor item •••••••••••• Trip data 6 Unit Magnification Data size Note Trip factor   8 bytes Inverter status A   8 bytes Inverter status B   8 bytes Inverter status C   8 bytes Output frequency Hz × 10 8 bytes Decimal ASCII code Total RUN time h ×1 8 bytes Decimal ASCII code Output current A × 10 8 bytes Decimal ASCII code DC voltage V × 10 8 bytes Decimal ASCII code Power ON time h ×1 8 bytes Decimal ASCII code Code display See "Command 04".  MSB LSB  Reads a setting item. •Transmission frame Frame format STX Station No. Command Parameter Description STX BCC Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 06 Parameter Parameter No. for data 4 bytes * Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR * All parameters except F001 and U001 to U012 are retrieved. 4-157 CR 4-4 Communication Function •Response frame Positive response Frame format STX Station No. ACK Data Description STX BCC CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 ACK Control code (ACKnowledge) 1 byte ACK (0x06) Data Data (Decimal ASCII code) 8 bytes * BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) Station No. CR Data on H003 and H203 (motor capacity selection) are the following code data. Code data 00 01 02 03 04 05 06 07 08 09 10 Domestic/USA mode (b085 = 00 or 02) 0.2 kW  0.4  0.75  1.5 2.2  3.7  EU mode (b085 = 01) 0.2 kW 0.37  0.55 0.75 1.1 1.5 2.2 3.0  4.0 Code data 11 12 13 14 15 16 17 18 19 20 21 Domestic/USA mode (b085 = 00 or 02) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75 EU mode (b085 = 01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75 Code data 22 23 24 25 26 Domestic/USA mode (b085 = 00 or 02) 90 kW 110 132 150 160 EU mode (b085 = 01) 90 kW 110 132 150 160 •If the data is a numeric value, refer to the function code list. (Example) When acceleration time F002 is set to 30.00 sec, the data is "3000". Negative response: Refer to page 4-161. 4-158 Functions * If the data is a selected item, the corresponding code data is received/transmitted. 4 4-4 Communication Function Writes data to a specified setting item. •Transmission frame Frame format STX Station No. Command Parameter Description STX Functions 4 Data BCC Data size CR Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32, and FF (Communication with all stations) Command Transmission command 2 bytes 07 Parameter Parameter No. for data 4 bytes *1 Data Parameter data (Decimal ASCII code) 8 bytes *2 BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) CR *1 Allowable parameter ranges are shown below. From F002, A001, b001, C001, H001, and P001 (For F001, use command 01.) *2 Refer to command 06. •Response frame Positive response: Refer to page 4-161. Negative response: Refer to page 4-161. Initializes each set value. Initialization conforms to the setting of initialization selection b084. If b084 is "00", the trip data is cleared. •Transmission frame Frame format STX Station No. Command BCC Description STX Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32, and FF (Communication with all stations) Command Transmission command 2 bytes 08 Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR •Response frame Positive response: Refer to page 4-161. Negative response: Refer to page 4-161. 4-159 CR 4-4 Communication Function Checks if a set value can be stored in EEPROM. •Transmission frame Frame format STX Station No. Command BCC Description STX CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 09 Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR Functions •Response frame Frame format STX Station No. ACK Data Description STX BCC CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 ACK Control code (ACKnowledge) 1 byte ACK (0x06) Data Data 2 bytes 01: Enabled BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) Station No. CR Negative response: Refer to page 4-161. Stores a set value in EEPROM. •Transmission frame Frame format STX Station No. Command BCC Description STX CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 0A Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR 4 •Response frame Positive response: Refer to page 4-161. Negative response: Refer to page 4-161. 4-160 4-4 Communication Function Re-calculates internal parameters. Recalculation is required when the base frequency and H*** parameters are changed via RS485 communication. •Transmission frame Frame format STX Station No. Command BCC Description STX Functions 4 CR Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 0B Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) BCC CR •Response frame Positive response: Refer to page 4-161. Negative response: Refer to page 4-161. Positive/Negative Responses •Response frame Frame format STX Station No. ACK BCC Description STX Data size Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 ACK Control code (ACKnowledge) 1 byte ACK (0x06) BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) Station No. CR 4-161 CR 4-4 Communication Function •Response frame Frame format STX Station No. NAK Description STX Station No. NAK Error code BCC CR Error code BCC Data size CR Setting Control code (Start of TeXt) 1 byte STX (0x02) Station No. of the target Inverter 2 bytes 01 to 32 Control code (Negative AcKnowledge) 1 byte NAK (0x15) Communication error status 2 bytes * Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-163.) Control code (Carriage Return) 1 byte CR (0x0D) Functions * Error Code List Error code Description 01H Parity error 02H Checksum error 03H Framing error 04H Overrun error 05H Protocol error 06H ASCII code error 07H Receiving buffer overrun error 08H Receiving timeout error     11H 12H 13H Command invalid error  Execution disabled error 14H  15H  16H 17H 4 Parameter invalid error  During communication with all stations, the Inverter sends no response. 4-162 4-4 Communication Function BCC (Block Check Code) Calculation Method (Example) To set "5 Hz" using command 01 (frequency reference setting) (When the target station No. is "01") Transmission Frame Structure STX Station No. Command Data BCC CR ASCII code (0x 02) 01 (0x 30 31) 01 000500 (0x 30 31) (0x 30 30 30 35 30 30) 05 4 (0x 30 35) (0x 00) Functions To determine BCC, the Inverter performs ASCII conversion from the station No. to data, and calculates a result of the exclusive OR (Xor) per byte. For the above transmission frame, BCC is calculated as follows: 30 31 Xor 01 Xor 31 30 31 Xor 00 Xor 30 30 Xor 00 30 Xor 30 30 Xor 05 35 30 Xor 35 30 Xor 05 ......This value is BCC. (Appendix) ASCII Code Conversion Table 4-163 Text data ASCII code Text data ASCII code STX 2 A 41 ACK 6 B 42 CR 0D C 43 NAK 15 D 44 0 30 E 45 1 31 F 46 2 32 H 48 3 33 P 50 b 62 4 34 5 35 6 36 7 37 8 38 9 39 4-4 Communication Function ModBus-RTU Method Follow the procedures below in regards to communication between the external controller and the Inverter. (1) (1) External controller Time Inverter (2) Wait time (silent interval + C078) (3) Communication error timeout C077 (Operates according to communication error selection C076 when reception times out.) Parameter No. Function name Data Default setting Unit C076 Communication error selection 00: Trip (Trip after receiving timeout [E41]) 01: Decel-Trip (Deceleration stop after receiving timeout. Trip after stop [E41]) 02: Ignore (No trip and no alarm output) 03: Free-RUN (Free-run stop after receiving timeout. No trip and no alarm output) 04: Decel-Stop (Deceleration stop after receiving timeout. No trip and no alarm output) 02  C077 Communication error timeout 0.00 to 99.99: Time before receiving timeout 0.00  0  C078 0 to 1000: Wait time until response starts after Communication wait time reception is completed (excluding silent interval) Response from the Inverter (Frame 2) is output as return after the Inverter receives the query (Frame 1), not output independently. 4-164 Functions (1) : Frame to be sent from the external control device to the Inverter (Query) (2) : Frame to be returned from the Inverter to the external controller (Response) (3) : Unless the Inverter completes reception of a query from the host within the time set in C077 after the Inverter completes a response (response transmission), the Inverter becomes ready to receive the first data again. In this case, the Inverter sends no response. Also, the Inverter's operation conforms to the setting of communication error selection C076. For details, refer to the following table. The receiving timeout monitor starts after the first transmission/reception is performed after power-on or reset. Receiving timeout is inactive until reception or transmission is performed. 4 4-4 Communication Function Below is each frame format (command). Message Configuration: Query Header (Silent interval) Slave address Function code Data Error check Trailer (Silent interval) 4 Functions •Pre-set numbers ranging from 1 to 247 in each Inverter (slave). (Only the Inverter having the same slave address as the query takes in the corresponding query.) •Broadcasting can be performed by setting the slave address to "0". •Data call or loop-back cannot be performed while broadcasting. •Sends the function command. •The RX corresponds with the following data formats used in the ModBus. Data name Description Coil 2-value data (1-bit long) that can be referred to or changed Holding register 16-bit long data that can be referred to or changed •Specifies the function for the Inverter to perform. •Below are the function codes supported by the RX. Function Code Function code Function Maximum number of data bytes in 1 message Maximum data number in 1 message 01h Reading coil status 4 32 coils (in bits) 03h Reading holding register content 8 4 registers (in bytes) 05h Writing into the coil 2 1 coil (in bits) 06h Writing into the holding register 2 1 register (in bytes) 08h Loop-back test  0Fh Writing into multiple coils 4 32 coils (in bits) 10h Writing into multiple registers 8 4 registers (in bytes) •CRC (Cyclic Redundancy Check) is used for the ModBus-RTU error check. •The CRC code is a 16-bit data generated for the block of random length data in the 8-bit unit. •To prepare the CRC code, use a generation polynomial of CRC-16 (X16 + X15 + X2 + 1). 4-165 4-4 Communication Function CRC-16 Calculation Example CRC-16 calculation CRC*1 Hi CRC*1 = FFFFh Target data Lo CRC register (2 bytes) Exists CRC*1 = CRC*1 XOR target data All target data completed 8-bit shift 4 Completed Bits left 0 Functions Interchange the Hi and Lo bytes of CRC*1 Shift CRC*1 = CRC*1 by 1 bit to the right Overflow bit after shift 1 Completed CRC*1 = CRC*1 XOR A001h Shift by 1 byte against target data •Wait time from receiving the query from the master to the response by the Inverter. •Be sure to provide 3.5 characters (24 bits) as the wait time. If the length does not reach 3.5 characters, the Inverter does not respond. •The actual communication wait time is the total of the silent interval (3.5-character length) and C078 (communication wait time) setting. Message Configuration: Response •The time from receiving query to the response by the Inverter is the total of the silent interval (3.5character length) and C078 (communication wait time) setting. •If sending another query to the Inverter after receiving the response, be sure to provide the silent interval length (3.5 characters) at the minimum. •If the query is the loop-back function code (08h), the Inverter sends back a response of the same content as the query. •If the query is the function code to be written into the holding register or coil (05h, 06h, 0Fh, 10h), the Inverter sends back the query as it is in response. •If the query is the function code to be read from the holding register or coil (01h, 03h), the Inverter makes the slave address and function code the same as the query and attaches the read data to the query. 4-166 4-4 Communication Function Field Configuration Slave address Function code Exception code CRC-16 •If an error (aside from a communication error) is found in the query content, the Inverter returns exception responses without performing any operation. •To determine the cause of an error, check the function code of the response. The function code of the exception response is the value of the query function code to which 80h is added. •Check the details of the error with the exception code. 4 Exception code Functions Code Description 01h An unsupported function has been specified. 02h Specified address does not exist. 03h Specified data has an unacceptable format. 21h Data is out of the Inverter's range for writing into the holding register. 22h The Inverter does not allow this function. • Has attempted to change the register that cannot be changed during operation. • Has issued the enter command during operation (UV). • Has written into the register during trip (UV). • Has written into the read-only register (coil) The Inverter ignores the query and does not respond if: •The broadcast is received. •A communication error is detected in receiving a query. •The query slave address does not correspond with the slave address set for the Inverter. •The time interval between 2 pieces of data that configure the message is less than a 3.5-character length. •Query data length is inappropriate. Note: If the timer is set in the master to monitor response, but no response is returned within the set time period, send the same query again. 4-167 4-4 Communication Function Explanation of Each Function Code Reads out the coil status (ON/OFF). (Example) Read multi-function input terminals 1 to 6 on the Inverter with slave address 8. Refer to the following table for the multi-function input terminal status. Multi-function input terminals 1 2 3 4 5 6 Coil No. 7 8 9 10 11 12 Terminal status ON ON ON OFF ON OFF Query 4 Response Field name 1 Slave address *1 2 Function code Example (HEX) No. 08 1 Slave address 08 01 2 Function code 01 *2 Field name Example (HEX) 3 Coil start number (MSB) 00 3 Number of data bytes 01 4 Coil start number (LSB)*2 06 4 Coil data *4 17 5 Number of coils (MSB)*3 00 5 CRC-16 (MSB) 12 6 CRC-16 (LSB) 1A *3 6 Number of coils (LSB) 06 7 CRC-16 (MSB) 5C 8 CRC-16 (LSB) 90 *4. Transfers data by the number of data bytes. *1. Broadcasting cannot be performed. *2. Note that the start number is reduced by 1. *3. When specifying the value of 0 or over 32 for the number of reading coils, the error code "3h" is replied. The data received as the response shows the status of coils 7 to 14. The data received here, "17h = 00010111b", should be read with coil 7 as LSB, as follows: Coil No. 14 13 12 11 10 9 8 7 Coil status OFF OFF OFF ON OFF ON ON ON If the read coil exceeds the defined coil range in the final coil data, such coil data is regarded as "0" and sent. If the coil status reading command has not been performed normally, refer to the "Exception Response" section. 4-168 Functions No. Coils 13 and 14 are OFF. 4-4 Communication Function Reads consecutively the specified number of holding register contents from the specified holding register address. (Example) Read past trip data from the Inverter with slave address 5. Below is the data on past three trips: 4 d081 (Previous factor) d081 (Previous Inverter status) Holding register No. 0012h 0013h Trip factor (high-order) Overvoltage (E07) During deceleration (02) Query No. Functions RX command Response Field name Example (HEX) No. Field name Example (HEX) 1 Slave address *1 05 1 Slave address 05 2 Function code 03 2 Function code 03 3 Register start number (MSB) *2 00 3 Number of data bytes *3 04 11 4 Register start number (MSB) 00 *2 4 Register start number (LSB) 5 Number of holding registers (MSB) 00 5 Register start number (LSB) 07 6 Number of holding registers (LSB) 02 6 Register start number +1 (MSB) 00 7 CRC-16 (MSB) 95 7 Register start number +1 (LSB) 02 8 CRC-16 (LSB) 8A 8 CRC-16 (MSB) 36 9 CRC-16 (LSB) 37 *1. Broadcasting cannot be performed. *2. Note that the start number is reduced by 1. *3. Transfers data by the number of data bytes. In this example, the Inverter sends response data on two holding registers (4 bytes). Read the data received in response, as follows: Response buffer 4 5 6 7 Holding register start number +0 (MSB) +0 (LSB) +1 (MSB) +1 (LSB) Response data 00h 07h 00h 02h Trip cause Overvoltage trip During deceleration If the holding register content has not been read out normally, refer to the "Exception Response" section. 4-169 4-4 Communication Function Writes into one coil. The following table shows the coil status change. Coil status OFF  ON ON  OFF Change data (MSB) FFh 00h Change data (LSB) 00h 00h (Example) Issue the RUN command to the Inverter with slave address 10. To run the Inverter, set "03" in A002. The coil number of the RUN command is "1". Query Response Field name 1 Slave address *1 2 Function code Example (HEX) No. 0A 1 Slave address 0A Field name Example (HEX) 05 2 Function code 05 Coil start number (MSB)*2 00 3 Coil start number (MSB) 00 4 Coil start number (LSB)*2 00 4 Coil start number (LSB) 00 5 Change data (MSB) FF 5 Change data (MSB) FF 6 Change data (LSB) 00 6 Change data (LSB) 00 7 CRC-16 (MSB) 8D 7 CRC-16 (MSB) 8D 8 CRC-16 (LSB) 41 8 CRC-16 (LSB) 41 3 *1. There is no response for broadcasting. *2. Note that the start number is reduced by 1. If writing into the coil cannot be performed normally, refer to the "Exception Response" section. 4-170 Functions No. 4 4-4 Communication Function Writes data into the specified holding register. (Example) Write 50 Hz into the Inverter with slave address 5 as the base frequency (A003). The data resolution of the holding register "1203h" of the base frequency (A003) is 1 Hz. To set 50 Hz, set the change data to "50 (0032h)". Query Response No. Functions 4 Field name Example (HEX) No. Field name Example (HEX) 1 Slave address *1 05 1 Slave address 05 2 Function code 06 2 Function code 06 3 Register start number (MSB) *2 12 3 Register start number (MSB) 12 4 Register start number (LSB)*2 02 4 Register start number (LSB) 02 5 Change data (MSB) 00 5 Change data (MSB) 00 6 Change data (LSB) 32 6 Change data (LSB) 32 7 CRC-16 (MSB) AD 7 CRC-16 (MSB) AD 8 CRC-16 (LSB) 23 8 CRC-16 (LSB) 23 *1. There is no response for broadcasting. *2. Note that the start number is reduced by 1. If writing into the holding register cannot be performed normally, refer to the "Exception Response" section. Used to check the communications between master and slave. A random value can be used for test data. (Example) Loop-back test to the Inverter with slave address 1 Query No. Response Field name Example (HEX) No. Field name Example (HEX) 1 Slave address * 01 1 Slave address 01 2 Function code 08 2 Function code 08 3 Diagnostic sub code (MSB) 00 3 Diagnostic sub code (MSB) 00 4 Diagnostic sub code (LSB) 00 4 Diagnostic sub code (LSB) 00 5 Data (MSB) Random 5 Data (MSB) Random 6 Data (LSB) Random 6 Data (LSB) Random 7 CRC-16 (MSB) CRC 7 CRC-16 (MSB) CRC 8 CRC-16 (LSB) CRC 8 CRC-16 (LSB) CRC * Broadcasting cannot be performed. The diagnostic sub code corresponds only with the query data echo (00h, 00h), not any other commands. 4-171 4-4 Communication Function Rewrites consecutive multiple coils. (Example) Change the status of multi-function input terminals 1 to 6 on the Inverter with slave address 5. Set the multi-function input terminals as shown in the following table. Multi-function input terminals 1 2 3 4 5 6 Coil No. 7 8 9 10 11 12 Terminal status ON ON ON OFF ON OFF Query No. 4 Response Field name Slave address *1 2 Function code No. 05 1 Slave address 05 Field name Example (HEX) 0F 2 Function code 0F Coil start number (MSB)*2 00 3 Coil start number (MSB) 00 4 Coil start number (LSB)*2 06 4 Coil start number (LSB) 06 5 Number of coils (MSB) 00 5 Number of coils (MSB) 00 6 Number of coils (LSB) 3 06 6 Number of coils (LSB) 06 *3 02 7 CRC-16 (MSB) 34 Change data (MSB)*3 17 8 CRC-16 (LSB) 4C 9 Change data (LSB)*3 00 10 CRC-16 (MSB) DB 11 CRC-16 (LSB) 3E 7 8 Number of bytes *1. There is no response for broadcasting. *2. Note that the start number is reduced by 1. *3. Since the change data comprises of both MSB and LSB as a set, make the byte to be an even number by adding 1, even if the byte that actually needs to be changed is an odd number. If writing into multiple coils cannot be performed normally, refer to the "Exception Response" section. 4-172 Functions 1 Example (HEX) 4-4 Communication Function Writes into consecutive multiple holding registers. (Example) Set acceleration time 1 (F002) to "3000 sec." for the Inverter with slave address 1. The data resolution of the holding register "1103h, 1104h" of acceleration time 1 (F002) is 0.01 seconds. To set to 3000 seconds, set data to "300000 (493E0h)". Query No. Functions 4 Field name Response Example (HEX) No. Field name Example (HEX) 1 Slave address *1 01 1 Slave address 01 2 Function code 10 2 Function code 10 3 Start address (MSB)*2 11 3 Start address (MSB) 11 4 Start address (LSB)*2 02 4 Start address (LSB) 02 5 Number of holding registers (MSB) 00 5 Number of holding registers (MSB) 00 6 Number of holding registers (LSB) 02 6 Number of holding registers (LSB) 02 7 Number of bytes *3 04 7 CRC-16 (MSB) E5 8 Change data 1 (MSB) 00 8 CRC-16 (LSB) 34 9 Change data 1 (LSB) 04 10 Change data 2 (MSB) 93 11 Change data 2 (LSB) E0 12 CRC-16 (MSB) 9E 13 CRC-16 (LSB) 9F *1. There is no response for broadcasting. *2. Note that the start address is reduced by 1. *3. Specifies the number of actual bytes to change, not the number of holding registers. If writing into multiple holding registers cannot be performed normally, refer to the "Exception Response" section. The master requires the response for a query except for broadcast. Though the Inverter should return a response corresponding with the query, it returns an exception response if the query has an error. The exception response has the field configuration shown in the following table. Field Configuration Slave address Function code Exception code CRC-16 The detailed field configuration is shown below. The function code of the exception response is the value of the query function code to which 80h is added. The exception code shows the cause of exception response. 4-173 4-4 Communication Function Function code Exception code Query Exception response Code 01h 81h 01h An unsupported function has been specified. 03h 83h 02h Specified address does not exist. 05h 85h 03h Specified data has an unacceptable format. 06h 86h 21h Data is out of the Inverter's range for writing into the holding register. 0Fh 8Fh 10h 90h Description The Inverter does not allow this function. 22h • Has attempted to change the register that cannot be changed during operation. • Has issued the enter command during operation (UV). • Has written into the register during trip (UV). • Has written into the read-only register (coil). Even if using the command to write into the holding register (06h) or into the consecutive holding registers (10h), no change can be saved in the Inverter's memory element. If the Inverter power shuts off without saving any changes, the holding register returns to the status before the changes were made. To save the holding register changes in the Inverter's memory element, the "Enter Command" must be issued according to the following procedure. When the control parameters are changed, the motor parameters must be re-calculated. In this case, perform re-calculation with this register. To issue the Enter command Write all memory data into the holding register with the write command (06h), and write recalculated motor parameters into holding register 0900h. Below are the values to be written into the holding register. Set value Description 0000 Motor parameter re-calculation 0001 Set value storage Other than the above Motor parameter re-calculation and set value storage Note •The Enter command needs considerable time. Monitor the data writing signal (coil number 0049h) to check whether the data is being written. •Since the Inverter's memory element has a limit on the number of rewrites (approx. 100,000 times), the Inverter life may be shortened if enter commands are frequently used. EEPROM Write Mode •If the holding register write command (06h), etc. is used to write "1" into the holding register for EEPROM write mode (0902h), the EEPROM write mode will become active. •If data is changed using the holding register write command (06h) after switching to the EEPROM write mode, the new data is written into both the volatile memory for operation (RAM) and nonvolatile memory for storage (EEPROM). At the same time, the EEPROM write mode is cancelled. •If any command other than the holding register write command (06h) is received after switching to the EEPROM write mode, the EEPROM write mode is cancelled. 4-174 Functions Saving the Change to the Holding Register (Enter Command) 4 4-4 Communication Function Difference between Enter Command and EEPROM Write Mode EEPROM write mode Enter command Master Parameter change Parameter change Parameter change Enter command 900h=1 Functions 4 4-175 3G3MX2 Write into RAM Master 3G3MX2 EEPROM write mode enabled 902h=1 Write into RAM Parameter change Write into RAM Write all data into EEPROM Parameter change Write into RAM and EEPROM (changed data only) Write into RAM The EEPROM write mode remains effective only for one parameter change. 4-4 Communication Function Register Number List R/W in the list shows whether the coil or holding register accepts reading and/or writing. R: Read only R/W: Read and write enabled Coil No. Item R/W Description  Not used 0001h RUN command R/W 1: Run 0: Stop (Enabled when A002 = 03) 0002h Rotation direction command R/W 1: Reverse 0: Forward (Enabled when A002 = 03) 0003h External trip (EXT) R/W 1: Trip 0004h Trip reset (RS) R/W 1: Reset 0005h Not used  0006h Not used  0007h Multi-function input terminal 1 R/W 1: ON 0: OFF *1 0008h Multi-function input terminal 2 R/W 1: ON 0: OFF *1 0009h Multi-function input terminal 3 R/W 1: ON 0: OFF *1 000Ah Multi-function input terminal 4 R/W 1: ON 0: OFF *1 000Bh Multi-function input terminal 5 R/W 1: ON 0: OFF *1 000Ch Multi-function input terminal 6 R/W 1: ON 0: OFF *1 000Dh Multi-function input terminal 7 R/W 1: ON 0: OFF *1 000Eh Multi-function input terminal 8 R/W 1: ON 0: OFF *1 000Fh Operation status R 1: Run 0: Stop (Interlocked with d003) 0010h Rotation direction R 1: Reverse 0: Forward (Interlocked with d003) 0011h Inverter ready R 1: Ready 0: Not ready 0012h Not used  0013h RUN (during RUN) R 1: During trip 0: Normal 0014h FA1 (constant speed arrival signal) R 1: ON 0: OFF 0015h FA2 (over set frequency arrival signal) R 1: ON 0: OFF 4 Functions 0000h *1. When either the control circuit terminal block or the coil is turned on, these settings are ON. The control circuit terminal block has the priority for the multi-function input terminals. If the master cannot reset the coil ON status because of communication disconnection, turn the control circuit terminal block from ON to OFF to turn off the coil. *2. The communications error is retained until a fault reset is input. (Can be reset during operation.) 4-176 4-4 Communication Function Coil No. R/W Description 0016h OL (overload warning) R 1: ON 0: OFF 0017h OD (excessive PID deviation) R 1: ON 0: OFF 0018h AL (alarm output) R 1: ON 0: OFF 0019h FA3 (set-frequency-only arrival signal) R 1: ON 0: OFF 001Ah OTQ (overtorque) R 1: ON 0: OFF 001Bh IP (signal during momentary power interruption) R 1: ON 0: OFF 001Ch UV (signal during undervoltage) R 1: ON 0: OFF 001Dh TRQ (torque limit) R 1: ON 0: OFF 001Eh RNT (RUN time over) R 1: ON 0: OFF 001Fh ONT (Power ON time over) R 1: ON 0: OFF 0020h THM (thermal warning) R 1: ON 0: OFF 0021h Not used  0022h Not used  0023h Not used  0024h Not used  0025h Not used  0026h BRK (brake release) R 1: ON 0: OFF 0027h BER (brake error) R 1: ON 0: OFF 0028h ZS (0 Hz signal) R 1: ON 0: OFF 0029h DSE (excessive speed deviation) R 1: ON 0: OFF 002Ah POK (position ready) R 1: ON 0: OFF 002Bh FA4 (set frequency exceeded 2) R 1: ON 0: OFF 002Ch FA5 (set frequency only 2) R 1: ON 0: OFF 002Dh OL2 (overload warning 2) R 1: ON 0: OFF 4 Functions Item *1. When either the control circuit terminal block or the coil is turned on, these settings are ON. The control circuit terminal block has the priority for the multi-function input terminals. If the master cannot reset the coil ON status because of communication disconnection, turn the control circuit terminal block from ON to OFF to turn off the coil. *2. The communications error is retained until a fault reset is input. (Can be reset during operation.) 4-177 4-4 Communication Function Coil No. Item R/W Description ODc (analog O disconnection detection) R 1: ON 0: OFF 002Fh OIDc (analog OI disconnection detection) R 1: ON 0: OFF 0030h O2Dc (analog O2 disconnection detection) R 1: ON 0: OFF 0031h Not used  0032h FBV (PID FB status output) R 1: ON 0: OFF 0033h NDc (network error) R 1: ON 0: OFF 0034h LOG1 (logic operation output 1) R 1: ON 0: OFF 0035h LOG2 (logic operation output 2) R 1: ON 0: OFF 0036h LOG3 (logic operation output 3) R 1: ON 0: OFF 0037h LOG4 (logic operation output 4) R 1: ON 0: OFF 0038h LOG5 (logic operation output 5) R 1: ON 0: OFF 0039h LOG6 (logic operation output 6) R 1: ON 0: OFF 003Ah WAC (capacitor life warning signal) R 1: ON 0: OFF 003Bh WAF (cooling fan life warning signal) R 1: ON 0: OFF 003Ch FR (starting contact signal) R 1: ON 0: OFF 003Dh OHF (fin overheat warning) R 1: ON 0: OFF 003Eh LOC (light load detection signal) R 1: ON 0: OFF 003Fh MO1 (Drive Programming output 1) R/W 1: ON 0: OFF 0040h MO2 (Drive Programming output 2) R/W 1: ON 0: OFF 0041h MO3 (Drive Programming output 3) R/W 1: ON 0: OFF 0042h MO4 (Drive Programming output 4) R/W 1: ON 0: OFF 0043h MO5 (Drive Programming output 5) R/W 1: ON 0: OFF 4 Functions 002Eh *1. When either the control circuit terminal block or the coil is turned on, these settings are ON. The control circuit terminal block has the priority for the multi-function input terminals. If the master cannot reset the coil ON status because of communication disconnection, turn the control circuit terminal block from ON to OFF to turn off the coil. *2. The communications error is retained until a fault reset is input. (Can be reset during operation.) 4-178 4-4 Communication Function Coil No. Item R/W R/W 1: ON 0: OFF IRDY (operation ready signal) R 1: ON 0: OFF 0046h FWR (forward run signal) R 1: ON 0: OFF 0047h RVR (reverse run signal) R 1: ON 0: OFF 0048h MJA (fatal fault signal) R 1: ON 0: OFF 0049h During data write R 1: Writing 0: Normal 004Ah CRC error R 1: Error 0: No error *2 004Bh Overrun error R 1: Error 0: No error *2 004Ch Framing error R 1: Error 0: No error *2 004Dh Parity error R 1: Error 0: No error *2 004Eh Checksum error R 1: Error 0: No error *2 004Fh Not used  0050h WCO (window comparator O) R 1: ON 0: OFF 0050h WCOI (window comparator OI) R 1: ON 0: OFF 0052h WCO2 (window comparator O2) R 1: ON 0: OFF 0044h MO6 (Drive Programming output 6) 0045h 4 Functions Description *1. When either the control circuit terminal block or the coil is turned on, these settings are ON. The control circuit terminal block has the priority for the multi-function input terminals. If the master cannot reset the coil ON status because of communication disconnection, turn the control circuit terminal block from ON to OFF to turn off the coil. *2. The communications error is retained until a fault reset is input. (Can be reset during operation.) 4-179 4-4 Communication Function Register No. Function name 0001h Function code R/W F001 (HIGH) R/W F001 (LOW) R/W Resolution 0.00 to 400.00 (Enabled when A001 = 03) Output frequency setting/monitor 0002h Monitor and setting parameters 0.01 [Hz] Inverter status A  R 0004h Inverter status B  R 0: During stop 1: During RUN 2: During trip  0:  1: Stop 2: Deceleration 3: Constant speed 4: Acceleration 5: Forward 6: Reverse 7: Forward to reverse 8: Reverse to forward 9: Forward run start 10: Reverse run start   4 Functions 0003h 0: Initial status 1:  2: Stop 3: RUN 4: Free-run stop 5: Jogging 6: DC injection braking 7: Retry 8: Trip 9: During UV 0005h Inverter status C  R 0006h PID feedback  R/W 0007h to 0010h Not used   0011h Fault frequency monitor d080 R 0012h Fault monitor 1 factor See "Inverter Trip Factor List" (page 4-183).  0013h Fault monitor 1 Inverter status See "Inverter Trip Factor List" (page 4-183).  0014h Fault monitor 1 frequency (HIGH) 0015h Fault monitor 1 frequency (LOW) 0016h Fault monitor 1 current 0017h Fault monitor 1 voltage 0018h Fault monitor 1 RUN time (HIGH) 0019h Fault monitor 1 RUN time (LOW) 001Ah Fault monitor 1 ON time (HIGH) 001Bh Fault monitor 1 ON time (LOW) 0.01 [%] 0 to 10000  0 to 65535 1 [time] 0.01 [Hz] 0.00 to 400.00 d081 R Output current value at the time of tripping 0.1 [A] DC input voltage at the time of tripping 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] Note 1: The Inverter's rated current is "1000". Note 2: If the set value is "10000" (100.0 sec) or more, the value in the second decimal place is ignored. 4-180 4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 001Ch Fault monitor 2 factor See "Inverter Trip Factor List" (page 4-183).  001Dh Fault monitor 2 Inverter status See "Inverter Trip Factor List" (page 4-183).  001Eh Fault monitor 2 frequency (HIGH) 0.01 [Hz] 0.00 to 400.00 Functions 4 001Fh Fault monitor 2 frequency (LOW) 0020h Fault monitor 2 current 0021h Fault monitor 2 voltage 0022h Fault monitor 2 RUN time (HIGH) 0023h Fault monitor 2 RUN time (LOW) 0024h Fault monitor 2 ON time (HIGH) 0025h Fault monitor 2 ON time (LOW) 0026h Fault monitor 3 factor See "Inverter Trip Factor List" (page 4-183).  0027h Fault monitor 3 Inverter status See "Inverter Trip Factor List" (page 4-183).  0028h Fault monitor 3 frequency (HIGH) d082 R Output current value at the time of tripping 0.1 [A] DC input voltage at the time of tripping 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] 0.01 [Hz] 0.00 to 400.00 0029h Fault monitor 3 frequency (LOW) 002Ah Fault monitor 3 current 002Bh Fault monitor 3 voltage 002Ch Fault monitor 3 RUN time (HIGH) 002Dh Fault monitor 3 RUN time (LOW) 002Eh Fault monitor 3 ON time (HIGH) 002Fh Fault monitor 3 ON time (LOW) 0030h Fault monitor 4 factor See "Inverter Trip Factor List" (page 4-183).  0031h Fault monitor 4 Inverter status See "Inverter Trip Factor List" (page 4-183).  0032h Fault monitor 4 frequency (HIGH) 0033h Fault monitor 4 frequency (LOW) 0034h Fault monitor 4 current 0035h Fault monitor 4 voltage 0036h Fault monitor 4 RUN time (HIGH) 0037h Fault monitor 4 RUN time (LOW) 0038h Fault monitor 4 ON time (HIGH) 0039h Fault monitor 4 ON time (LOW) d083 R Output current value at the time of tripping 0.1 [A] DC input voltage at the time of tripping 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] 0.01 [Hz] 0.00 to 400.00 d084 R Output current value at the time of tripping 0.1 [A] DC input voltage at the time of tripping 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] Note 1: The Inverter's rated current is "1000". Note 2: If the set value is "10000" (100.0 sec) or more, the value in the second decimal place is ignored. 4-181 4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 003Ah Fault monitor 5 factor See "Inverter Trip Factor List" (page 4-183).  003Bh Fault monitor 5 Inverter status See "Inverter Trip Factor List" (page 4-183).  003Ch Fault monitor 5 frequency (HIGH) 0.01 [Hz] 0.00 to 400.00 003Dh Fault monitor 5 frequency (LOW) 003Eh Fault monitor 5 current 003Fh Fault monitor 5 voltage 0040h Fault monitor 5 RUN time (HIGH) 0041h Fault monitor 5 RUN time (LOW) 0042h Fault monitor 5 ON time (HIGH) 0043h Fault monitor 5 ON time (LOW) 0044h Fault monitor 6 factor See "Inverter Trip Factor List" (page 4-183).  0045h Fault monitor 6 Inverter status See "Inverter Trip Factor List" (page 4-183).  0046h Fault monitor 6 frequency (HIGH) d085 R Output current value at the time of tripping 0.1 [A] 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] 0.01 [Hz] 0.00 to 400.00 0047h Fault monitor 6 frequency (LOW) 0048h Fault monitor 6 current 0049h Fault monitor 6 voltage 004Ah Fault monitor 6 RUN time (HIGH) 004Bh Fault monitor 6 RUN time (LOW) 004Ch Fault monitor 6 ON time (HIGH) 004Dh Fault monitor 6 ON time (LOW) 004Eh Warning monitor 004Fh to 08FFh Not used d086 R d090 R   Output current value at the time of tripping 0.1 [A] DC input voltage at the time of tripping 1 [V] Total RUN time before the trip 1 [h] Total power ON time before the trip 1 [h] Warning code 0 to 385   0000: Motor parameter recalculation 0001: Set value storage in EEPROM Other: Motor parameter recalculation and set value storage in EEPROM 0900h EEPROM write  W  0901h to 1000h Not used   1F01h Coil control word  R/W Register coil 0001h to 000Fh  1E01h Coil status word  R Register coil 0010h to 001Fh   Note 1: The Inverter's rated current is "1000". Note 2: If the set value is "10000" (100.0 sec) or more, the value in the second decimal place is ignored. 4-182 4 Functions DC input voltage at the time of tripping 4-4 Communication Function Inverter Trip Factor List Trip factor high-order (factor) Name Functions 4 Trip factor low-order (Inverter status) Code Name Code No trip factor 0 During reset 0 Overcurrent protection during constant speed 1 During stop 1 Overvoltage protection during deceleration 2 During deceleration 2 Overcurrent protection during acceleration 3 During constant speed 3 Overcurrent protection during stop 4 During acceleration 4 Overload protection 5 Operates at frequency = 0 5 Braking resistor overload protection 6 During startup 6 Overvoltage protection 7 During DB 7 EEPROM error 8 During overload limit 8 Undervoltage protection 9 During SON/FOC 9 CT error 10 CPU error 11 External trip 12 USP error 13 Grounding protection 14 Incoming overvoltage protection 15 Momentary power interruption protection 16 Power module abnormal temperature (during FAN stop) 20 Power module abnormal temperature 21 Gate array communications error 23 Input phase loss protection 24 Main circuit error 25 IGBT error 30 Thermistor error 35 Brake error addition 36 Emergency shutoff error 37 Low-speed-range electronic thermal 38 Option 1 errors 0 to 9 60 to 69 Option 2 errors 0 to 9 70 to 79 4-183 4-4 Communication Function Register No. Function name 1001h Output frequency monitor 1002h 1003h 1004h Output current monitor Rotation direction monitor 1005h PID feedback value monitor 1006h Function code d001 (HIGH) d001 (LOW) d002 d003 d004 (HIGH) d004 (LOW) R/W R Monitor and setting parameters Rresolution 0.00 to 400.00 0.01 [Hz] R 0.0 to 9999.0 0.1 [A] R FWD: Forward STOP: Stop REV: Reverse  R 0.00 to 999000.00  4 Multi-function input monitor d005 R 2^0: Terminal 1 to 2^7: Terminal 8 2^8: Terminal FW  1008h Multi-function output monitor d006 R 2^0: Terminal 11 to 2^4: Terminal 15 2^6: Relay terminal  R 0.00 to 39960.00 0.01 -400.00 to 400.00 0.01 [Hz] 1009h 100Ah Output frequency monitor (after conversion) 100Bh Real frequency monitor 100Ch d007 (HIGH) d007 (LOW) d008 (HIGH) R d008 (LOW) R 100Dh Torque reference monitor d009 R -200 to 200 1 [%] 100Eh Torque bias monitor d010 R -200 to 200 1 [%] 100Fh Not used   1010h Output torque monitor d012 R -200 to 200 1 [%] 1011h Output voltage monitor d013 R 0.0 to 600.0 0.1 [V] 1012h Input power monitor d014 R 0.0 to 999.9 [kW] R 0.0 to 999999.9 R 0 to 999999 1 [h] R 0 to 999999 1 [h] 1013h Integrated power monitor d015 (HIGH) 1014h d015 (LOW) 1015h d016 (HIGH) Total RUN time 1016h d016 (LOW) 1017h d017 (HIGH) Power ON time monitor 1018h d017 (LOW)  0.1 [h] 1019h Fin temperature monitor d018 R -020. to 200.0 0.1 [C] 101Ah Motor temperature monitor d019 R -020. to 200.0 0.1 [C]   d022 R 101Bh 101Ch 101Dh Not used Life assessment monitor  2^0: Capacitor on the main circuit board 2^1: Cooling fan rotation speed reduced  4-184 Functions 1007h 4-4 Communication Function Register No. 4 Function name R/W   Monitor and setting parameters Rresolution 101Eh to 1025h Not used 1026h DC voltage monitor d102 R 0.0 to 999.9 0.1 [V] 1027h Regenerative braking load rate monitor d103 R 0.0 to 100.0 0.1 [%] 1028h Electronic thermal monitor d104 R 0.0 to 100.0 0.1 [%] 1029h to 102Dh Not used   102Eh User monitor 0 Functions Function code d025 (HIGH) 102Fh d025 (LOW) 1030h d026 (HIGH) User monitor 1 1031h d026 (LOW) 1032h d027 (HIGH) User monitor 2   R -2147483647 to 2147483647 1 R -2147483647 to 2147483647 1 R -2147483647 to 2147483647 1 0 to 2147483647 1 -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected 1 1  1033h d027 (LOW) 1034h d028 (HIGH) R 1035h d028 (LOW) R 1036h d029 (HIGH) R 1037h d029 (LOW) R 1038h d030 (HIGH) R d030 (LOW) R -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected    d060 R/W Pulse counter monitor Position command monitor Current position monitor 1039h 103Ah to 1102h Not used 1057h Inverter mode 00 to 01  Register No. Function name 1103h Acceleration time 1 Function code F002 (HIGH) 1104h F002 (LOW) 1105h F003 (HIGH) Deceleration time 1 1106h 4-185 F003 (LOW) R/W Monitor and setting parameters Resolution R/W 0.01 to 3600.00 0.01 [s] R/W 0.01 to 3600.00 0.01 [s] 4-4 Communication Function Register No. Function name Function code R/W 1107h Operator rotation direction selection F004 R/W 1108h to 1200h Not used   Monitor and setting parameters 00: FWD (Forward) 01: REV (Reverse) Resolution   Register No. Frequency reference selection Function code A001 Resolution R/W Monitor and setting parameters R/W 00: VR (Digital Operator (FREQ adjuster)) 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 06: Pulse train frequency 07: EzSQ (Drive Programming) 10: (Math) Operation function result   4 1202h RUN command selection A002 R/W 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 1203h Base frequency A003 R/W 30 to Max. frequency 1 [Hz] 1204h Maximum frequency A004 R/W 30 to 400 1 [Hz] R/W 00: [O]/[O2] Switches between O/OI terminal 01: [O]/[O2] Switches between O/O2 terminal AT 02: [O]/VR Switches between O/FREQ adjuster via terminal AT 03: [OI]/VR Switches between OI/FREQ adjuster via terminal AT 04: [O2]/VR Switches between O2/FREQ adjuster via terminal AT  A006 R/W 0: [O2] only 1: [O/OI-P] auxiliary frequency reference (not reversible) 2: [O/OI-PM] auxiliary frequency reference (reversible) 3: [OFF] O2 disabled    1205h O/OI selection 1206h O2 selection 1207h to 120Ah Not used A005 A011 (HIGH) 120Bh O start frequency 120Ch A011 (LOW) 120Dh A012 (HIGH) O end frequency R/W 0.00 to 400.00 0.01 [Hz] R/W 0.00 to 400.00 0.01 [Hz] R/W 0 to 100 1 [%] A012 (LOW) 120Eh 120Fh  O start ratio A013 4-186 Functions 1201h Function name 4-4 Communication Function Register No. Function code R/W Monitor and setting parameters Resolution 1210h O end ratio A014 R/W 0 to 100 1211h O start selection A015 R/W 00: External start frequency (A011 set value) 01: 0 Hz  1212h O, O2, OI sampling A016 R/W 1 to 30 31: 500-ms filter with a hysteresis of ±0.1 Hz 1 1213h Drive Programming (EzSQ) Selection A017 R/W 00: Disable 01: [PRG] start 02: Always ON  1213h Not used    1214h Not used    1215h Multi-step speed selection A019 R/W A020 (HIGH) R/W 4 Functions Function name 1216h Multi-step speed reference 0 1217h A020 (LOW) R/W 1218h A021 (HIGH) R/W Multi-step speed reference 1 1219h A021 (LOW) R/W 121Ah A022 (HIGH) R/W Multi-step speed reference 2 121Bh A022 (LOW) R/W 121Ch A023 (HIGH) R/W Multi-step speed reference 3 121Dh A023 (LOW) R/W 121Eh A024 (HIGH) R/W Multi-step speed reference 4 121Fh A024 (LOW) R/W 1220h A025 (HIGH) R/W Multi-step speed reference 5 1221h A025 (LOW) R/W 1222h A026 (HIGH) R/W Multi-step speed reference 6 1223h A026 (LOW) R/W 1224h A027 (HIGH) R/W Multi-step speed reference 7 1225h 4-187 A027 (LOW) R/W 1 [%] 00: Binary: 16-step selection with 4 terminals 01: Bit: 8-step selection with 7 terminals  0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 4-4 Communication Function Register No. Function name 1226h Multi-step speed reference 8 1227h 1228h Multi-step speed reference 9 1229h 122Ah Multi-step speed reference 10 122Bh Multi-step speed reference 11 122Dh 122Eh Multi-step speed reference 12 122Fh 1230h Multi-step speed reference 13 1231h 1232h Multi-step speed reference 14 1233h 1234h Multi-step speed reference 15 1235h R/W A028 (HIGH) R/W A028 (LOW) R/W A029 (HIGH) R/W A029 (LOW) R/W A030 (HIGH) R/W A030 (LOW) R/W A031 (HIGH) R/W A031 (LOW) R/W A032 (HIGH) R/W A032 (LOW) R/W A033 (HIGH) R/W A033 (LOW) R/W A034 (HIGH) R/W A034 (LOW) R/W A035 (HIGH) R/W A035 (LOW) R/W Monitor and setting parameters Resolution 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 0/Starting frequency to Max. frequency 0.01 [Hz] 1236h Not used    1237h Not used    1238h Jogging frequency A038 R/W Starting frequency to 999 A039 R/W 00: FRS (Free-running on jogging stop/ Disabled in operation) 01: DEC (Deceleration stop on jogging stop/Disabled in operation) 02: DB (DC injection braking on jogging stop/Disabled in operation) 03: FRS (RUN) (Free running on jogging stop/Enabled in operation) 04: DEC (RUN) (Deceleration stop on jogging stop/Enabled in operation) 05: DB (RUN) (DC injection braking on jogging stop/Enabled in operation)   1239h Jogging stop selection 123Ah Not used 0.01 [Hz]   4-188 4 Functions 122Ch Function code 4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 123Bh Torque boost selection A041 R/W 00: Manual torque boost 01: Automatic torque boost 123Ch Manual torque boost voltage A042 R/W 0.0 to 20.0 0.1 [%] 123Dh Manual torque boost frequency A043 R/W 0.0 to 50.0 0.1 [%] 4 123Eh V/f characteristics selection A044 R/W 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) Functions  123Fh Output voltage gain A045 R/W 20 to 100 1 [%] 1240h Automatic torque boost voltage compensation gain A046 R/W 0 to 255 1 [%] 1241h Automatic torque boost slip compensation gain A047 R/W 0 to 255 1 [%] 1242h to 1244h Not used   1245h DC injection braking selection A051 R/W 00: OFF (Disabled) 01: ON (Enabled) 02: ON (FQ) (Frequency control [A052 set value]) 1246h DC injection braking frequency A052 R/W 0.00 to 400.00 1247h DC injection braking delay time A053 R/W 0.0 to 5.0 0.1 [s] 1248h DC injection braking power A054 R/W 0 to 100 (0.4 to 55 kW) 0 to 80 (75 to 132 kW) 1 [%] 1249h DC injection braking time A055 R/W 0.0 to 60.0 0.1 [s] 124Ah DC injection braking method selection A056 R/W 00: Edge operation 01: Level operation 124Bh Startup DC injection braking power A057 R/W 0 to 100 (0.4 to 55 kW) 0 to 80 (75 to 132 kW) 1 [%] 124Ch Startup DC injection braking time A058 R/W 0.0 to 60.0 0.1 [s] 124Dh DC injection braking carrier frequency A059 R/W 0.5 to 15.0 (0.4 to 55 kW) 0.5 to 10.0 (75 to 132 kW) 124Eh Not used   A061 (HIGH) R/W 1250h A061 (LOW) R/W 1251h A062 (HIGH) R/W A062 (LOW) R/W 124Fh Frequency upper limit Frequency lower limit 1252h 4-189    0.01 [Hz]  0.1 [kHz]  0.00/Frequency lower limit to Max. frequency 0.01 [Hz] 0.00/Starting frequency to Frequency upper limit 0.01 [Hz] 4-4 Communication Function Register No. Function name 1253h Function code R/W A063 (HIGH) R/W Jump frequency 1 1254h 1255h Jump frequency width 1 1256h A063 (LOW) R/W A064 R/W A065 (HIGH) R/W Jump frequency 2 1257h 1258h Jump frequency width 2 R/W A066 R/W A067 (HIGH) R/W Jump frequency 3 125Ah 125Bh Jump frequency width 3 125Ch Acceleration stop frequency 125Dh A067 (LOW) R/W A068 R/W A069 (HIGH) R/W A069 (LOW) R/W Resolution 0.00 to 400.00 0.01 [Hz] 0.00 to 10.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 4 0.00 to 10.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 0.00 to 10.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 125Eh Acceleration stop time A070 R/W 0.0 to 60.0 125Fh PID selection A071 R/W 00: OFF (Disabled) 01: ON (+) (Enabled) 02: ON (+/-) (Reverse output enabled)  1260h PID P gain A072 R/W 0.2 to 5.0 0.1 1261h PID I gain A073 R/W 0.0 to 3600.0 0.1 [s] 1262h PID D gain A074 R/W 0.00 to 100.00 0.01 [s] 1263h PID scale A075 R/W 0.01 to 99.99 0.01 R/W 00: OI 01: O 02: Modbus (RS485 communication) 03: Pulse (Pulse train frequency) 10: Math (Operation function output)   1264h PID feedback selection A076 0.1 [s] 1265h Reverse PID function A077 R/W 00: OFF (Deviation = Target value Feedback value) 01: ON (Deviation = Feedback value Target value) 1266h PID output limit function A078 R/W 0.0 to 100.0 0.1 [s] A079 R/W 00: Disabled 01: O 02: OI 03: O2    A081 R/W 1267h PID feedforward selection 1268h Not used 1269h AVR selection  00: Always ON 01: Always OFF 02: OFF during deceleration  4-190 Functions 1259h A065 (LOW) Monitor and setting parameters 4-4 Communication Function Register No. Functions 4 Function name 126Ah AVR voltage selection 126Bh Function code R/W Monitor and setting parameters 200-V class: 0 (200) 1 (215) 2 (220) 3 (230) 4 (240) 400-V class: 5 (380) 6 (400) 7 (415) 8 (440) 9 (460) 10 (480) Resolution  A082 R/W Not used    126Ch Not used    126Dh RUN mode selection A085 R/W 00: Normal operation 01: Energy-saving operation 02: Automatic operation 126Eh Energy-saving response/ accuracy adjustment A086 R/W 0.0 to 100.0 126Fh to 1273h Not used   A092 (HIGH) R/W 1274h Acceleration time 2 1275h A092 (LOW) R/W 1276h A093 (HIGH) R/W Deceleration time 2 A093 (LOW) 1277h 1278h 2-step acceleration/ deceleration selection 1279h 2-step acceleration frequency 127Ah 127Bh 2-step deceleration frequency 127Ch 127Dh 127Eh 4-191 Acceleration pattern selection Deceleration pattern selection R/W A095 (HIGH) R/W 0.01 to 3600.00 0.01 [s] 0.01 to 3600.00 0.01 [s] 00: 2CH-Terminal (Switched via multifunction input 09) 01: Preset FQ (Switched by setting) 02: FWD-REV (Enabled only when switching forward/reverse)  0.01 [Hz] 0.00 to 400.00 0.01 [Hz] R/W 00: Line 01: S-curve 02: U-curve 03: inv.U curve 04: EL-S curve  R/W 00: Line 01: S-curve 02: U-curve 03: inv.U curve 04: EL-S curve  R/W A096 (HIGH) R/W A098  0.00 to 400.00 A095 (LOW) A097 0.1 [%] R/W A094 A096 (LOW)  R/W 4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 127Fh Not used    1280h Not used    A101 (HIGH) R/W 1281h OI start frequency 1282h A101 (LOW) R/W 1283h A102 (HIGH) R/W OI end frequency 1284h A102 (LOW) R/W 0.00 to 400.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] OI start ratio A103 R/W 0 to OI end ratio 1 [%] 1286h OI end ratio A104 R/W OI start ratio to 100 1 [%] 1287h OI start selection A105 R/W 00: Start FQ (Use OI start frequency [A101]) 01: 0 Hz 1288h to 128Ch Not used   A111 (HIGH) R/W 128Dh O2 start frequency 128Eh A111 (LOW) R/W 128Fh A112 (HIGH) R/W O2 end frequency 1290h A112 (LOW) R/W   -400.00 to 400.00 0.01 [Hz] -400.00 to 400.00 0.01 [Hz] 1291h O2 start ratio A113 R/W -100 to O2 end ratio 1 [%] 1292h O2 end ratio A114 R/W O2 start ratio to 100 1 [%] 1293h to 12A4h Not used   12A5h Acceleration curve parameter A131 R/W 01: Small curve to 10: Large curve  12A6h Deceleration curve parameter A132 R/W 01: Small curve to 10: Large curve  12A7h to 12AEh Not used   12AFh Operation frequency input A setting A141 R/W   00: Operator (Digital Operator (F001)) 01: VR (Digital Operator (FREQ adjuster)) 02: O (Input O) 03: OI (Input OI) 04: Modbus (RS485 communication) 05: Option 1 06: Option 2 07: Pulse (Pulse train frequency)  4-192 Functions 1285h 4 4-4 Communication Function Register No. Function name R/W Monitor and setting parameters Resolution   12B0h Operation frequency input B setting A142 R/W 00: Operator (Digital Operator (F001)) 01: VR (Digital Operator (FREQ adjuster)) 02: O (Input O) 03: OI (Input OI) 04: Modbus (RS485 communication) 05: Option 1 06: Option 2 07: Pulse (Pulse train frequency) 12B1h Operator selection A143 R/W 00: ADD (Addition (A + B)) 01: SUB (Subtraction (A - B)) 02: MUL (Multiplication (A × B)) 12B2h Not used   A145 (HIGH) R/W 4 12B3h Functions Function code Frequency addition amount 12B4h  0.00 to 400.00 A145 (LOW) R/W A146 R/W   0.01 [Hz] 12B5h Frequency addition direction 12B6h to 12B8h Not used 12B9h EL-S-curve ratio 1 during acceleration A150 R/W 0 to 50 1 [%] 12BAh EL-S-curve ratio 2 during acceleration A151 R/W 0 to 50 1 [%] 12BBh EL-S-curve ratio 1 during deceleration A152 R/W 0 to 50 1 [%] 12BCh EL-S-curve ratio 2 during deceleration A153 R/W 0 to 50 1 [%] 12BDh to 1300h Not used   00: ADD (Frequency reference + A145) 01: SUB (Frequency reference - A145)    1301h Retry selection b001 R/W 00: TRIP (Alarm) 01: 0-Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) 1302h Allowable momentary power interruption time b002 R/W 0.3 to 25.0 0.1 [s] 1303h Retry wait time b003 R/W 0.3 to 100.0 0.1 [s] 1304h Momentary power interruption/undervoltage trip during stop selection b004 R/W 00: OFF (Disabled) 01: ON (Enabled) 02: Decel-OFF (Disabled during stop and deceleration stop)  1305h Momentary power interruption retry time selection b005 R/W 00: 16 times 01: No limit  1306h Input phase loss protection selection b006 R/W 00: OFF (Disabled) 01: ON (Enabled)  4-193  4-4 Communication Function Register No. Function name 1307h Frequency matching lower limit frequency setting 1308h 1309h Trip retry selection Function code R/W b007 (HIGH) R/W Monitor and setting parameters 0.00 to 400.00 b007 (LOW) b008 Resolution 0.01 [Hz] R/W R/W 00: TRIP (Alarm) 01: 0-Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart)  4 Undervoltage retry time selection b009 R/W 00: 16 times 01: No limit  130Bh Overvoltage/overcurrent retry time selection b010 R/W 1 to 3  130Ch Trip retry wait time b011 R/W 0.3 to 100.0 0.1 [s] 130Dh Electronic thermal level b012 R/W 0.20 x Rated current to 1.00 x Rated current 0.1 [A] b013 R/W 00: Reduced TRQ (Reducted torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting)    130Eh Electronic thermal characteristics selection 130Fh Not used 1310h Free setting, electronic thermal frequency 1 b015 R/W 0 to 400 1 [Hz] 1311h Free setting, electronic thermal current 1 b016 R/W 0.0 to Rated current 0.1 [A] 1312h Free setting, electronic thermal frequency 2 b017 R/W 0 to 400 1 [Hz] 1313h Free setting, electronic thermal current 2 b018 R/W 0.0 to Rated current 0.1 [A] 1314h Free setting, electronic thermal frequency 3 b019 R/W 0 to 400 1 [Hz] 1315h Free setting, electronic thermal current 3 b020 R/W 0.0 to Rated current 0.1 [A] R/W 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/constant speed operation) 02: ON-Cnst (Enabled during constant speed operation) 03: ON-A/C (R) (Enabled in acceleration/ constant speed operation (accelerates during regeneration)) 0.1 [A] 0.01 [s] 1316h Overload limit selection b021  1317h Overload limit level b022 R/W 0.20 x Rated current to 2.00 x Rated current (0.4 to 55 kW) 0.20 x Rated current to 1.80 x Rated current (75 to 132 kW) 1318h Overload limit parameter b023 R/W 0.10 to 30.00  4-194 Functions 130Ah 4-4 Communication Function Register No. 1319h Functions 4 Function name Overload limit selection 2 Function code b024 R/W Monitor and setting parameters Resolution R/W 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/constant speed operation) 02: ON-Cnst (Enabled during constant speed operation) 03: ON-A/C (R) (Enabled in acceleration/ constant speed operation (accelerates during regeneration))  0.1 [A] 0.01 [s] 131Ah Overload limit level 2 b025 R/W 0.20 x Rated current to 2.00 x Rated current (0.4 to 55 kW) 0.20 x Rated current to 1.80 x Rated current (75 to 132 kW) 131Bh Overload limit parameter 2 b026 R/W 0.10 to 30.00 131Ch Overcurrent suppression function b027 R/W 00: OFF (Disabled) 01: ON (Enabled) 131Dh Active Frequency Matching restart level b028 R/W 0.20 x Rated current to 2.00 x Rated current (0.4 to 55 kW) 0.20 x Rated current to 1.80 x Rated current (75 to 132 kW) 0.1 [A] 131Eh Active Frequency Matching restart parameter b029 R/W 0.10 to 30.00 0.01 [s] 131Fh Starting frequency at Active Frequency Matching restart b030 R/W 00: Off FQ (Frequency at interruption) 01: Max.FQ (Max. frequency) 02: Set FQ (Set frequency)  b031 R/W 00: Lock (SFT) (Data other than b031 cannot be changed when terminal SFT is ON) 01: Only FQ (SFT) (Data other than b031 and the specified frequency parameter cannot be changed when terminal SFT is ON) 02: Lock (Data other than b031 cannot be changed) 03: Only FQ (Data other than b031 and the specified frequency parameter cannot be changed) 10: RUN chg mode (Data other than parameters changeable during operation cannot be changed)   1320h Soft lock selection 1321h Not used    1322h Not used    b034 (HIGH) R/W b034 (LOW) R/W 1323h RUN time/Power ON time setting 1324h 0 to 65535 1325h Rotation direction limit selection b035 1326h Reduced voltage startup selection b036 4-195 1 [h] R/W 00: FREE (Forward and Reverse are enabled) 01: FWD (Only Forward is enabled) 02: REV (Only Reverse is enabled)  R/W 0: (Reduced voltage startup time: Short) to 255: (Reduced voltage startup time: Long)  4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 1327h Display selection b037 R/W 00: All (Complete display) 01: Utilized (Individual display of functions) 02: User (User setting) 03: Compare (Data comparison display) 04: Basic (Basic display) 1328h Initial screen selection b038 R/W 000 to 202  1329h User parameter automatic setting function selection b039 R/W 00: OFF (Disabled) 01: ON (Enabled)   132Ah Torque limit selection b040 R/W 00: 4-quadrant (Four-quadrant separate setting) 01: TRQ input (Terminal switch) 02: [O] input (Analog Input) 03: Option 1 04: Option 2 132Bh Torque limit 1 (Four-quadrant mode forward power running) b041 R/W 0 to 200 (0.4 to 55 kW)/ 0 to 180 (75 to 132 kW) no (Torque limit disabled) 1 [%] 132Ch Torque limit 2 (Four-quadrant mode reversed regeneration) b042 R/W 0 to 200 (0.4 to 55 kW)/ 0 to 180 (75 to 132 kW) no (Torque limit disabled) 1 [%] 132Dh Torque limit 3 (Four-quadrant mode reversed power running) b043 R/W 0 to 200 (0.4 to 55 kW)/ 0 to 180 (75 to 132 kW) no (Torque limit disabled) 1 [%] 132Eh Torque limit 4 (Four-quadrant mode forward regeneration) b044 R/W 0 to 200 (0.4 to 55 kW)/ 0 to 180 (75 to 132 kW) no (Torque limit disabled) 1 [%] 132Fh Torque LADSTOP selection b045 R/W 00: OFF (Disabled) 01: ON (Enabled)  1330h Reverse rotation prevention selection b046 R/W 00: OFF (Disabled) 01: ON (Enabled)  1331h to 1332h Not used   1333h Dual rate selection b049 R/W 00: CT (Constant torque) 01: VT (Variable torque)  1334h Selection of non-stop function at momentary power interruption b050 R/W 00: OFF (Disabled) 01: V-Cnst (STOP) (Enabled (Deceleration stop)) 02: NS1 (Enabled (without recovery)) 03: NS2 (Enabled (with recovery))  1335h Starting voltage of non-stop function at momentary power interruption b051 R/W 0.0 to 1000.0 0.1 [V] 1336h Starting deceleration level of non-stop function at momentary power interruption b052 R/W 0.0 to 1000.0 0.1 [V] b053 (HIGH) R/W 0.01 to 3600.00 0.01 [s] b053 (LOW) R/W 1338h Deceleration time of non-stop function at momentary power interruption   4-196 Functions 1337h 4 4-4 Communication Function Functions 4 Register No. Function name Function code R/W 1339h Deceleration starting width of non-stop function at momentary power interruption b054 R/W 0.00 to 10.00 0.01 [Hz] 133Ah Proportional gain setting of non-stop function at momentary power interruption b055 R/W 0.00 to 2.55 0.01 133Bh Integral time setting of non-stop function at momentary power interruption b056 R/W 0.000 to 65.535 133Ch to 133Eh Not used   133Fh Window comparator O upper limit level 1340h Window comparator O lower limit level 1341h Window comparator O hysteresis width 1342h Window comparator OI upper limit level 1343h Window comparator OI lower limit level 1344h Window comparator OI hysteresis width 1345h Window comparator O2 upper limit level 1346h Window comparator O2 lower limit level 1347h 4-197 Window comparator O2 hysteresis width b060 b061 b062 b063 b064 b065 b066 b067 b068 Monitor and setting parameters Resolution 0.001 [s]  R/W Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 1 [%] R/W Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 1 [%] R/W Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 1 [%] R/W Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 1 [%] R/W Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 1 [%] R/W Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 1 [%] R/W Set an upper limit level. Setting range: -100 to 100 Lower limit: Lower limit level + Hysteresis width × 2 1 [%] R/W Set a lower limit level. Setting range: -100 to 100 Upper limit: Upper limit level - Hysteresis width × 2 1 [%] R/W Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 1 [%] 4-4 Communication Function Register No. Function name Function code R/W   Monitor and setting parameters Resolution  Not used 1349h Analog operation level at O disconnection b070 R/W 0 to 100/no (ignored) 1 [%] 134Ah Analog operation level at OI disconnection b071 R/W 0 to 100/no (ignored) 1 [%] 134Bh Analog operation level at O2 disconnection b072 R/W -100 to 100/no (ignored) 1 [%] 134Ch to 1350 Not used   1351h Integrated power clear b078 R/W Cleared with the Enter key after changing to 01  1352h Integrated power display gain b079 R/W 1 to 1000 1 1353h Not used    1354h Not used    1355h Starting frequency b082 R/W 0.10 to 9.99 1356h Carrier frequency b083 R/W 0.5 to 15.0 (0.4 to 55 kW) 0.5 to 10.0 (75 to 132 kW)   0.01 [Hz] 0.1 [kHz] 1357h Initialization selection b084 R/W 00: no (Clears the trip monitor) 01: Trip data (Initializes data) 02: Parameters (Clears the trip monitor and initializes data) 03: Trip+Param (Clears the trip monitor and parameters) 04: Trp+Prm+EzSQ (Clears the trip monitor, parameters and Drive Program) 1358h Initialization parameter selection b085 R/W 01 *Do not change.  1359h Frequency conversion coefficient b086 R/W 0.1 to 99.9 0.1 R/W 00: ON (Enabled) 01: OFF (Disabled) 02: Only RESET (Disabled only during stop)    135Ah STOP key selection b087 135Bh Free-run stop selection b088 R/W 00: 0-Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart) 135Ch Automatic carrier reduction b089 R/W 00: OFF (Disabled) 01: ON (Enabled) 135Dh Usage rate of regenerative braking function b090 R/W 0.0 to 100.0 135Eh Stop selection b091 R/W 00: Decel-Stop (Deceleration  Stop) 01: Free-RUN (Free-run stop)  135Fh Cooling fan control b092 R/W 00: Alws-ON (Always ON) 01: ON in RUN (ON during RUN)  1360h Not used    1361h Not used    0.1 [%] 4-198 4 Functions 1348h 4-4 Communication Function Register No. Functions 4 Function name Function code R/W Monitor and setting parameters Resolution 1362h Regenerative braking function operation selection b095 R/W 00: OFF (Disabled) 01: RUN-ON (Enabled (Disabled during stop)) 02: Alws-ON (Enabled (Enabled during stop)) 1363h Regenerative braking function ON level b096 R/W 330 to 380 660 to 760 1364h Not used   1365h Thermistor selection b098 R/W 00: Disabled 01: PTC enabled 02: NTC enabled 1366h Thermistor error level b099 R/W 0 to 9999 1 [] 1367h Free V/f frequency 1 b100 R/W 0 to Free V/f frequency 2 1 [Hz] 1368h Free V/f voltage 1 b101 R/W 0.0 to 800.0 0.1 [V] 1369h Free V/f frequency 2 b102 R/W 0 to Free V/f frequency 3 1 [Hz] 136Ah Free V/f voltage 2 b103 R/W 0.0 to 800.0 0.1 [V] 136Bh Free V/f frequency 3 b104 R/W 0 to Free V/f frequency 4 1 [Hz] 136Ch Free V/f voltage 3 b105 R/W 0.0 to 800.0 0.1 [V] 136Dh Free V/f frequency 4 b106 R/W 0 to Free V/f frequency 5 1 [Hz] 136Eh Free V/f voltage 4 b107 R/W 0.0 to 800.0 0.1 [V] 136Fh Free V/f frequency 5 b108 R/W 0 to Free V/f frequency 6 1 [Hz] 1370h Free V/f voltage 5 b109 R/W 0.0 to 800.0 0.1 [V] 1371h Free V/f frequency 6 b110 R/W 0 to Free V/f frequency 7 1 [Hz] 1372h Free V/f voltage 6 b111 R/W 0.0 to 800.0 0.1 [V] 1373h Free V/f frequency 7 b112 R/W 0 to 400 1 [Hz] 1374h Free V/f voltage 7 b113 R/W 0.0 to 800.0 0.1 [V] 1375h to 137Ah Not used   137Bh Brake control selection b120 R/W 00: OFF (Disabled) 01: ON (Enabled) 137Ch Brake wait time for release b121 R/W 0.00 to 5.00 0.01 [s] 137Dh Brake wait time for acceleration b122 R/W 0.00 to 5.00 0.01 [s] 137Eh Brake wait time for stopping b123 R/W 0.00 to 5.00 0.01 [s] 137Fh Brake wait time for confirmation b124 R/W 0.00 to 5.00 0.01 [s] 1380h Brake release frequency b125 R/W 0.00 to -400.00 1381h Brake release current b126 R/W 0.0 to 2.00 x Rated current (0.4 to 55 kW) 0.0 to 1.80 x Rated current (75 to 132 kW) 1382h Brake input frequency b127 R/W 0.00 to 400.00 1383h Not used    1384h Not used    4-199  1 [V]     0.01 [Hz] 0.1 [A] 0.01 [Hz] 4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 1385h Overvoltage protection function selection during deceleration b130 R/W 00: OFF (Disabled) 01: V-const (DC voltage kept constant) 02: Accel (Acceleration enabled) 1386h Overvoltage protection level during deceleration b131 R/W 200-V class: 330 to 390 (V) 400-V class: 660 to 780 (V) 1387h Overvoltage protection parameter b132 R/W 0.10 to 30.00 0.01 [s] 1388h Overvoltage protection proportional gain setting b133 R/W 0.00 to 2.55 0.01 1389h Overvoltage protection integral time setting b134 R/W 0.000 to 65.535 1390h to 1400h Not used    1 [V] 0.001 [s] 4-200 Functions  4 4-4 Communication Function Register No. Function name Function code R/W 01: RV (reverse) 02: CF1 (multi-step speed setting binary 1) 03: CF2 (multi-step speed setting binary 2) 04: CF3 (multi-step speed setting binary 3) 05: CF4 (multi-step speed setting binary 4) 06: JG (jogging) 07: DB (external DC injection braking) 08: SET (2nd control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (free-run stop) 12: EXT (external trip) 13: USP (USP function) 14: CS (commercial switch) 15: SFT (soft lock) 16: AT (analog input switching) 17: SET3 (3rd control) 18: RS (reset) 20: STA (3-wire start) 21: STP (3-wire stop) 22: F/R (3-wire forward/reverse) 23: PID (PID enabled/disabled) 24: PIDC (PID integral reset) 26: CAS (control gain switching) 27: UP (UP/DWN function accelerated) 28: DWN (UP/DWN function decelerated) 29: UDC (UP/DWN function data clear) 31: OPE (forced operator) 32: SF1 (multi-step speed setting bit 1) 33: SF2 (multi-step speed setting bit 2) 34: SF3 (multi-step speed setting bit 3) 35: SF4 (multi-step speed setting bit 4) 36: SF5 (multi-step speed setting bit 5) 37: SF6 (multi-step speed setting bit 6) 38: SF7 (multi-step speed setting bit 7) 39: OLR (overload limit switching) 40: TL (torque limit enabled) 41: TRQ1 (torque limit switching 1) 42: TRQ2 (torque limit switching 2) 43: PPI (P/PI switching) 44: BOK (Brake confirmation) 45: ORT (orientation) 46: LAC (LAD cancel) 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission) 50: ADD (frequency addition) 51: F-TM (forced terminal block) 52: ATR (torque command input permission) 53: KHC (integrated power clear) 54: SON (servo ON) 55: FOC (preliminary excitation) 56: MI1 (Drive Programming input 1) 57: MI2 (Drive Programming input 2) 58: MI3 (Drive Programming input 3) 59: MI4 (Drive Programming input 4) 60: MI5 (Drive Programming input 5) 61: MI6 (Drive Programming input 6) 62: MI7 (Drive Programming input 7) 63: MI8 (Drive Programming input 8) 65: AHD (analog command held) 66: CP1 (position command selection 1) 67: CP2 (position command selection 2) 68: CP3 (position command selection 3) 69: ORL (zero return limit signal) 70: ORG (zero return startup signal) 71: FOT (forward driving stop) 72: ROT (reverse driving stop) 73: SPD (speed/position switching) 74: PCNT (pulse counter) 75: PCC (pulse counter clear) 82: PRG (Drive program start) no: NO (no allocation) Resolution 1401h Multi-function input 1 selection C001 R/W 1402h Multi-function input 2 selection C002 R/W 1403h Multi-function input 3 selection C003 R/W 1404h Multi-function input 4 selection C004 R/W 1405h Multi-function input 5 selection C005 R/W 1406h Multi-function input 6 selection C006 R/W 1407h Multi-function input 7 selection C007 R/W 1408h Multi-function input 8 selection C008 R/W 1409h Not used    140Ah Not used    4 Functions Monitor and setting parameters 4-201         4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution Multi-function input 1 operation selection C011 R/W  140Ch Multi-function input 2 operation selection C012 R/W  140Dh Multi-function input 3 operation selection C013 R/W  140Eh Multi-function input 4 operation selection C014 R/W  140Fh Multi-function input 5 operation selection C015 R/W 1410h Multi-function input 6 operation selection C016 R/W  1411h Multi-function input 7 operation selection C017 R/W  1412h Multi-function input 8 operation selection C018 R/W  1413h FW terminal operation selection C019 R/W  1414h Not used    00: NO 01: NC  4-202 4 Functions 140Bh 4-4 Communication Function Register No. Function code R/W 1415h Multi-function output terminal 11 selection C021 R/W 1416h Multi-function output terminal 12 selection C022 R/W 1417h Multi-function output terminal 13 selection C023 R/W 1418h Multi-function output terminal 14 selection C024 R/W 1419h Multi-function output terminal 15 selection C025 R/W 141Ah Relay output (AL2, AL1) function selection C026 R/W 4 Functions Function name 4-203 Monitor and setting parameters 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) 03: OL (overload warning) 04: OD (excessive PID deviation) 05: AL (alarm output) 06: FA3 (set-frequency-only arrival signal) 07: OTQ (overtorque) 08: IP (signal during momentary power interruption) 09: UV (signal during undervoltage) 10: TRQ (torque limit) 11: RNT (RUN time over) 12: ONT (Power ON time over) 13: THM (thermal warning) 19: BRK (brake release) 20: BER (brake error) 21: ZS (0 Hz signal) 22: DSE (excessive speed deviation) 23: POK (position ready) 24: FA4 (set frequency exceeded 2) 25: FA5 (set frequency only 2) 26: OL2 (overload warning 2) 27: ODc (analog O disconnection detection) 28: OIDc (analog OI disconnection detection) 29: O2Dc (analog O2 disconnection detection) 31: FBV (PID FB status output) 32: NDc (network error) 33: LOG1 (logic operation output 1) 34: LOG2 (logic operation output 2) 35: LOG3 (logic operation output 3) 36: LOG4 (logic operation output 4) 37: LOG5 (logic operation output 5) 38: LOG6 (logic operation output 6) 39: WAC (capacitor life warning signal) 40: WAF (cooling fan life warning signal) 41: FR (starting contact signal) 42: OHF (fin overheat warning) 43: LOC (light load detection signal) 44: MO1 (Drive Programming output 1) 45: MO2 (Drive Programming output 2) 46: MO3 (Drive Programming output 3) 47: MO4 (Drive Programming output 4) 48: MO5 (Drive Programming output 5) 49: MO6 (Drive Programming output 6) 50: IRDY (operation ready signal) 51: FWR (forward run signal) 52: RVR (reverse run signal) 53: MJA (fatal fault signal) 54: WCO (window comparator O) 55: WCOI (window comparator OI) 56: WCO2 (window comparator O2) 63: OPO (option board output) no: Not used (When alarm code output is selected in C062, AC0 to AC2, or AC0 to AC3 (ACn: alarm code output) are forced to be allocated to multi-function output terminals 11 to 13, or 11 to 14.) Resolution       4-4 Communication Function Register No. 141Bh FM selection AM selection Function code C027 C028 Resolution R/W Monitor and setting parameters R/W 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 03: Pulse FQ (Digital output frequency) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 12: YA0 (Drive Programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2)  R/W 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 11: Out TRQ sign (Output torque (signed)) 13: YA1 (Drive Programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2)   4 Functions 141Ch Function name 141Dh AMI selection C029 R/W 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 14: YA2 (Drive Programming) 141Eh Digital current monitor reference value C030 R/W 0.20 x Rated current to 2.00 x Rated current (Current value at the digital current monitor output 1440 Hz) 141Fh Multi-function output terminal 11 contact selection C031 R/W  1420h Multi-function output terminal 12 contact selection C032 R/W  1421h Multi-function output terminal 13 contact selection C033 R/W 1422h Multi-function output terminal 14 contact selection C034 R/W  1423h Multi-function output terminal 15 contact selection C035 R/W  00: NO 01: NC 0.1 [A]  4-204 4-4 Communication Function Register No. 4 1424h Relay output (AL2, AL1) contact selection 1425h Not used Function code R/W Monitor and setting parameters Resolution C036 R/W 00: NO contact at AL2, NC contact at AL1 01: NC contact at AL2, NO contact at AL1     1426h Light load signal output mode C038 R/W 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) 1427h Light load detection level C039 R/W 0.0 to 2.00 x Rated current (0.4 to 55 kW) 0.0 to 1.80 x Rated current (75 to 132 kW) 0.1 [A] R/W 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed)  C041 R/W 0.0: Does not operate. 0.1 x Rated current to 2.00 x Rated current (0.4 to 55 kW) 0.1 x Rated current to 1.80 x Rated current (75 to 132 kW) C042 (HIGH) R/W 1428h Functions Function name 1429h Overload warning signal output mode Overload warning level 142Ah Arrival frequency during acceleration 142Bh 142Ch Arrival frequency during deceleration 142Dh 142Eh PID deviation excessive level 142Fh Arrival frequency during acceleration 2 1430h 1431h Arrival frequency during deceleration 2 1432h C040 C042 (LOW) R/W C043 (HIGH) R/W C043 (LOW) R/W C044 R/W C045 (HIGH) R/W C045 (LOW) R/W C046 (HIGH) R/W C046 (LOW) R/W    0.1 [A] 0.00 to 400.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 0.0 to 100.0 0.1 [%] 0.00 to 400.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 1433h to 1437h Not used 1438h PID FB upper limit C052 R/W 0.0 to 100.0 0.1 [%] 1439h PID FB lower limit C053 R/W 0.0 to 100.0 0.1 [%] 143Ah Not used   143Bh Overtorque level (Forward power running) C055 R/W 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 1 [%] 143Ch Overtorque level (Reverse regeneration) C056 R/W 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 1 [%] 143Dh Overtorque level (Reverse power running) C057 R/W 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 1 [%] 4-205   4-4 Communication Function Register No. Function name Function code R/W C058 R/W Monitor and setting parameters 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) Resolution 143Eh Overtorque level (Forward regeneration) 143Fh Not used    1440h Not used    1441h Thermal warning level C061 R/W 0 to 100 1442h Alarm code selection C062 R/W 00: OFF (Disabled) 01: 3-bit 02: 4-bit 1443h 0-Hz detection level C063 R/W 0.00 to 100.00 0.01 [Hz] 1444h Fin overheat warning level C064 R/W 0 to 200 1 [C] 1445h to 144Ah Not used   144Bh Communication speed selection (Baud rate selection) C071 144Ch Communication station No. selection 144Dh 1 [%] 1 [%]  R/W 02: Loop-back test 03: 2400 bps 04: 4800 bps 05: 9600 bps 06: 19200 bps  C072 R/W 1 to 247  Communication bit length selection C073 R/W 7: 7-bit 8: 8-bit  144Eh Communication parity selection C074 R/W 00: No parity 01: Even 02: Odd  144Fh Communication stop bit selection C075 R/W 1: 1-bit 2: 2-bit   1450h Communication error selection C076 R/W 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free-RUN (Free-run stop) 04: Decel-Stop (Deceleration stop) 1451h Communication error timeout C077 R/W 0.00 to 99.99 0.01 [s] 1452h Communication wait time C078 R/W 0 to 1000 1 [ms] 1453h Communication method selection C079 R/W 00: ASCII 01: ModBus-RTU 1454h Not used   1455h O adjustment C081 R/W 0 to 65535 1 1456h OI adjustment C082 R/W 0 to 65535 1 1457h O2 adjustment C083 R/W 0 to 65535 1 1458h Not used   1459h Thermistor adjustment C085 R/W 145Ah to 145Eh Not used      0.0 to 1000.0 0.1  4-206 Functions  4 4-4 Communication Function Register No. Functions 4 Function name 145Fh Debug mode selection 1460h to 1468h Not used 1469h UP/DWN selection Function code R/W C091 R/W   C101 R/W 00: Not save (Do not store the frequency data) 01: Save (Store the frequency data)  R/W 00: ON-RESET (Trip reset at power-on) 01: OFF-RESET (Trip reset at power-off) 02: On in Trip (Enabled only during trip (Reset at power-on)) 03: Trip RESET (Trip reset only)  C103 R/W 00: 0-Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart)    00 *Do not change Resolution   146Ah Reset selection 146Bh Reset frequency matching selection 146Ch Not used 146Dh FM gain setting C105 R/W 50 to 200 1 [%] 146Eh AM gain setting C106 R/W 50 to 200 1 [%] 146Fh AMI gain setting C107 R/W 50 to 200 1 [%] 1470h Not used   1471h AM bias setting C109 R/W 0 to 100 1 [%] 1472h AMI bias setting C110 R/W 0 to 100 1 [%] 1473h Overload warning level 2 C111 R/W 0.0 to 2.00 x Rated current (0.4 to 55 kW) 0.0 to 1.80 x Rated current (75 to 132 kW) 1474h to 147Ch Not used   147Dh O zero adjustment C121 R/W 0 to 65535 1 147Eh OI zero adjustment C122 R/W 0 to 65535 1 147Fh O2 zero adjustment C123 R/W 0 to 65535 1 1480h to 1485h Not used   4-207 C102 Monitor and setting parameters   0.1 [A]   4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution 1486h Output 11 ON delay C130 R/W 0.1 [s] 1487h Output 11 OFF delay C131 R/W 0.1 [s] 1488h Output 12 ON delay C132 R/W 0.1 [s] 1489h Output 12 OFF delay C133 R/W 0.1 [s] 148Ah Output 13 ON delay C134 R/W 0.1 [s] 148Bh Output 13 OFF delay C135 R/W 0.1 [s] 0.0 to 100.0 Output 14 ON delay C136 R/W 0.1 [s] 148Dh Output 14 OFF delay C137 R/W 0.1 [s] 148Eh Output 15 ON delay C138 R/W 0.1 [s] 148Fh Output 15 OFF delay C139 R/W 0.1 [s] 1490h Relay output ON delay C140 R/W 0.1 [s] 1491h Relay output OFF delay C141 R/W 0.1 [s] 1492h Logic output signal 1 selection 1 C142 R/W Same as C021 to C026 (except LOG1 to LOG6)  1493h Logic output signal 1 selection 2 C143 R/W Same as C021 to C026 (except LOG1 to LOG6)  1494h Logic output signal 1 operator selection C144 R/W 00: AND 01: OR 02: XOR  1495h Logic output signal 2 selection 1 C145 R/W Same as C021 to C026 (except LOG1 to LOG6)  1496h Logic output signal 2 selection 2 C146 R/W Same as C021 to C026 (except LOG1 to LOG6)  1497h Logic output signal 2 operator selection C147 R/W 00: AND 01: OR 02: XOR  1498h Logic output signal 3 selection 1 C148 R/W Same as C021 to C026 (except LOG1 to LOG6)  1499h Logic output signal 3 selection 2 C149 R/W Same as C021 to C026 (except LOG1 to LOG6)  149Ah Logic output signal 3 operator selection C150 R/W 00: AND 01: OR 02: XOR  149Bh Logic output signal 4 selection 1 C151 R/W Same as C021 to C026 (except LOG1 to LOG6)  149Ch Logic output signal 4 selection 2 C152 R/W Same as C021 to C026 (except LOG1 to LOG6)  149Dh Logic output signal 4 operator selection C153 R/W 00: AND 01: OR 02: XOR  149Eh Logic output signal 5 selection 1 C154 R/W Same as C021 to C026 (except LOG1 to LOG6)  149Fh Logic output signal 5 selection 2 C155 R/W Same as C021 to C026 (except LOG1 to LOG6)  14A0h Logic output signal 5 operator selection C156 R/W 00: AND 01: OR 02: XOR  4-208 4 Functions 148Ch 4-4 Communication Function Register No. Functions 4 Function name Function code R/W Monitor and setting parameters Resolution 14A1h Logic output signal 6 selection 1 C157 R/W Same as C021 to C026 (except LOG1 to LOG6)  14A2h Logic output signal 6 selection 2 C158 R/W Same as C021 to C026 (except LOG1 to LOG6)  14A3h Logic output signal 6 operator selection C159 R/W 00: AND 01: OR 02: XOR  14A4h Input terminal response time 1 C160 R/W 0 to 200 (× 2 ms) 1 14A5h Input terminal response time 2 C161 R/W 0 to 200 (× 2 ms) 1 14A6h Input terminal response time 3 C162 R/W 0 to 200 (× 2 ms) 1 14A7h Input terminal response time 4 C163 R/W 0 to 200 (× 2 ms) 1 14A8h Input terminal response time 5 C164 R/W 0 to 200 (× 2 ms) 1 14A9h Input terminal response time 6 C165 R/W 0 to 200 (× 2 ms) 1 14AAh Input terminal response time 7 C166 R/W 0 to 200 (× 2 ms) 1 14ABh Input terminal response time 8 C167 R/W 0 to 200 (× 2 ms) 1 14ACh FW terminal response time C168 R/W 0 to 200 (× 2 ms) 1 14ADh Multi-step speed/position determination time C169 R/W 0 to 200 (× 2 ms) 1 14AEh to 1500h Not used   1501h Auto-tuning selection H001 R/W 00: OFF (Disabled) 01: ON (STOP) 02: ON (Rotation)    1502h Motor parameter selection H002 R/W 00: Standard motor parameter 01: Auto-tuning parameter 02: Auto-tuning parameter (online auto-tuning enabled) 1503h Motor capacity selection H003 R/W 0.20 to 160.0 1504h Motor pole number selection H004 R/W 2/4/6/8/10 Pole H005 (HIGH) R/W 0.001 to 80.000 0.001 1505h Speed response 1506h 1507h Stabilization parameter 1508h to 1514h Not used 4-209 H005 (LOW) R/W H006 R/W   0 to 255 0.1 [kW] 1  4-4 Communication Function Register No. Function name 1515h Function code R/W H020 (HIGH) R/W Motor parameter R1 1516h H020 (LOW) R/W 1517h H021 (HIGH) R/W Motor parameter R2 1518h H021 (LOW) R/W 1519h H022 (HIGH) R/W Motor parameter L H022 (LOW) R/W 151Bh H023 (HIGH) R/W Motor parameter IO 151Ch H023 (LOW) R/W 151Dh H024 (HIGH) R/W Motor parameter J 151Eh 151Fh to 1523h Not used 1524h Motor parameter R1 (auto-tuning data) H024 (LOW) R/W   H030 (HIGH) R/W 1525h H030 (LOW) R/W 1526h H031 (HIGH) R/W Motor parameter R2 (auto-tuning data) 1527h H031 (LOW) R/W 1528h H032 (HIGH) R/W Motor parameter L (auto-tuning data) 1529h H032 (LOW) R/W 152Ah H033 (HIGH) R/W Motor parameter IO (auto-tuning data) 152Bh H033 (LOW) R/W 152Ch H034 (HIGH) R/W Motor parameter J (auto-tuning data) 152Dh H034 (LOW) R/W   Resolution 0.001 to 65.535 0.001 [] 0.001 to 65.535 0.001 [] 0.01 to 655.35 0.01 [mH] 0.01 to 655.35 0.01 [A] 0.001 to 9999.000 0.001 [kgm2]  0.001 to 65.535 0.001 [] 0.001 to 65.535 0.001 [] 0.01 to 655.35 0.01 [mH] 0.01 to 655.35 0.01 [A] 0.001 to 9999.000 0.001 [kgm2] 152Eh to 153Ch Not used 153Dh PI proportional gain H050 R/W 0.0 to 1000.0 0.1 [%] 153Eh PI integral gain H051 R/W 0.0 to 1000.0 0.1 [%]  4-210 4 Functions 151Ah Monitor and setting parameters 4-4 Communication Function Register No. Functions 4 Function name Function code R/W H052 R/W   Monitor and setting parameters 0.01 to 10.00 Resolution 153Fh P proportional gain 0.01 1540h to 1546h Not used 1547h Limit at 0 Hz H060 R/W 0.0 to 100.0 1548h Boost amount at SLV startup, 0 Hz H061 R/W 0 to 50 1549h to 1550h Not used   1551h For PI proportional gain switching H070 R/W 0.0 to 1000.0 0.1 [%] 1552h For PI integral gain switching H071 R/W 0.0 to 1000.0 0.1 [%] 1553h For P proportional gain switching H072 R/W 0.00 to 10.00 0.01 1554h Gain switching time H073 R/W 0 to 9999 1555h to 1600h Not used   1601h Operation selection at option 1 error P001 R/W 00: Trip 01: RUN (Continues operation)  1602h Operation selection at option 2 error P002 R/W 00: Trip 01: RUN (Continues operation)  1603h to 160Ah Not used   160Bh Encoder pulses P011 R/W 128 to 65535 1   0.1 [%] 1 [%]  1 [ms]   160Ch V2 control mode selection P012 R/W 00: ASR (speed control mode) 01: APR (pulse train position control mode) 02: APR2 (absolute position control mode) 03: HAPR (High resolution absolute position control mode) 160Dh Pulse train mode selection P013 R/W 00: Mode 1 01: Mode 2 02: Mode 3  160Eh Orientation stop position P014 R/W 0 to 4095 1 160Fh Orientation speed setting P015 R/W Starting frequency to Max. frequency (upper limit: 120.0) 1610h Orientation direction setting P016 R/W 00: FWD (Forward side) 01: REV (Reverse side)  1611h Position ready range setting P017 R/W 0 to 10000 1 1612h Position ready delay time setting P018 R/W 0.00 to 9.99 0.01 [s] 1613h Electronic gear setting position selection P019 R/W 00: FB (Position feedback side) 01: REF (Position command side) 4-211 0.01 [Hz]  4-4 Communication Function Register No. Function name Function code R/W Monitor and setting parameters Resolution Electronic gear ratio numerator P020 R/W 1 to 9999  1615h Electronic gear ratio denominator P021 R/W 1 to 9999  1616h Position control feedforward gain P022 R/W 0.00 to 655.35 0.01 1617h Position loop gain P023 R/W 0.00 to 100.00 0.01 1618h Position bias amount P024 R/W -2048 to 2048  1619h Secondary resistance compensation enable/ disable selection P025 R/W 00: OFF (Disabled) 01: ON (Enabled)  161Ah Overspeed error detection level P026 R/W 0.0 to 150.0 161Bh Speed deviation error detection level P027 R/W 0.00 to 120.00 161Ch Motor gear ratio numerator P028 R/W 1 to 9999 1 161Dh Motor gear ratio denominator P029 R/W 1 to 9999 1 161Eh Not used   161Fh Acceleration/deceleration time input type P031 1620h Orientation stop position input type P032 0.1 [%] 0.01 [Hz]  R/W 00: OPE (Digital Operator) 01: Option 1 02: Option 2 03: EzSQ (Drive Programming)  R/W 00: OPE (Digital Operator) 01: Option 1 02: Option 2   1621h Torque reference input selection P033 R/W 00: O (Terminal O) 01: OI (Terminal OI) 02: O2 (Terminal O2) 03: OPE (Digital Operator) 06: Option 1 07: Option 2 1622h Torque reference setting P034 R/W 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 1623h Polarity selection at torque reference via O2 P035 R/W 00: Sign (Signed) 01: Direction (Depends on the RUN direction)   1 [%] 1624h Torque bias mode P036 R/W 00: OFF (None) 01: OPE (Digital Operator) 02: O2 (Terminal O2) 05: Option 1 06: Option 2 1625h Torque bias value P037 R/W -200 to 200 (0.4 to 55 kW) -180 to 180 (75 to 132 kW) 1626h Torque bias polarity selection P038 R/W 00: Sign (Signed) 01: Direction (Depends on the RUN direction) P039 (HIGH) R/W 1627h Speed limit value in torque control (forward) 1628h 0.00 to Maximum frequency P039 (LOW) 1 [%]  0.01 [Hz] R/W 4-212 4 Functions 1614h 4-4 Communication Function Register No. Function name 1629h Speed limit value in torque control (reverse) 162Ah Functions 4 Function code R/W P040 (HIGH) R/W Monitor and setting parameters 0.00 to 1st Max. frequency P040 (LOW) R/W Resolution 0.01 [Hz] 162Bh Not used    162Ch Not used    162Dh Not used    162Eh DeviceNet comm Watch dog timer P044 R/W 0.00 to 99.99 [s] R/W 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop)  R/W 0: Basic speed I/O 1: Extended speed I/O 2: Extended speed and Torque control 3: Special I/O 4: Extended control I/O 5: Extended control I/O and multifunction I/O monitor 6: Flexible format 7: Extended speed and Acceleration control 8-20: Not used    162Fh 1630h Operation setting at communications error Instance Number P045 P046 1632h Operation setting at idle mode detection P048 R/W 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) 1633h Polarity setting for rotation speed P049 R/W 0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/ 30/32/34/36/38 1634h to 1638h Not used   1639h Pulse train frequency scale P055 R/W 1.0 to 50.0 * Input frequency at maximum frequency 163Ah Pulse train frequency filter time constant P056 R/W 0.01 to 2.00 0.01 [s] 163Bh Pulse train frequency bias amount P057 R/W -100 to 100 1 [%] 163Ch Pulse train frequency limit P058 R/W 0 to 100 1 [%] 163Dh Not used   P060 (HIGH) R/W 163Eh Multi-step position command 0 163Fh 4-213 P060 (LOW) R/W  0.1 [kHz]  Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 4-4 Communication Function Register No. Function name 1640h Multi-step position command 1 1641h 1642h Multi-step position command 2 1643h 1644h Multi-step position command 3 1645h Multi-step position command 4 1647h 1648h Multi-step position command 5 1649h 164Ah Multi-step position command 6 164Bh 164Ch Multi-step position command 7 164Dh R/W Monitor and setting parameters Resolution P061 (HIGH) R/W Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 1 P061 (LOW) R/W P062 (HIGH) R/W P062 (LOW) R/W P063 (HIGH) R/W P063 (LOW) R/W P064 (HIGH) R/W P064 (LOW) R/W P065 (HIGH) R/W P065 (LOW) R/W P066 (HIGH) R/W P066 (LOW) R/W P067 (HIGH) R/W P067 (LOW) R/W 4 164Eh Zero return mode P068 R/W 00: Low speed 01: High speed 1 02: High speed 2  164Fh Zero return direction selection P069 R/W 00: FWD (Forward side) 01: REV (Reverse side)  1650h Low-speed zero return frequency P070 R/W 0.00 to 10.00 0.01 [Hz] 1651h High-speed zero return frequency P071 R/W 0.00 to Maximum frequency 0.01 [Hz] P072 (HIGH) R/W 1652h Position range specification (forward) 1653h P072 (LOW) R/W 1654h P073 (HIGH) R/W Position range specification (reverse) 1655h P073 (LOW) 0 to 268435455 (at P012 = 02)/ 0 to 1073741823 (at P012 = 03) 1 -268435455 to 0 (at P012 = 02)/ -1073741823 to 0 (at P012 = 03) 1 R/W 4-214 Functions 1646h Function code 4-4 Communication Function Register No. Function name 1656h Teaching selection 1656h to 1665h Not used 1666h to 1685h Drive Program parameter U(00) to U(31) 1686h to 16A1h Not used 16A2h to 16ABh Function code R/W 00: X00 (Multi-step position command 0 (P060)) 01: X01 (Multi-step position command 0 (P061)) 02: X02 (Multi-step position command 0 (P062)) 03: X03 (Multi-step position command 0 (P063)) 04: X04 (Multi-step position command 0 (P064)) 05: X05 (Multi-step position command 0 (P065)) 06: X06 (Multi-step position command 0 (P066)) 07: X07 (Multi-step position command 0 (P067)) Resolution  P074 R/W   P100 to P131 R/W   Option I/F cmd W register 1 to 10 P160 to P169 R/W 0000 to FFFF  16ACh to 16B5h Option I/F cmd R register 1 to 10 P170 to P179 R/W 0000 to FFFF  16B6h Profibus node address P180 R/W 0 to 125  16B7h Profibus clear mode P181 R/W 00: Clear 01: Last value  16B8h Profibus Map selection P182 R/W 00: PPO 01: Conventional 02: Flexible mode  16BBh CANOpen Node address P185 R/W 0 to 127   4 Functions Monitor and setting parameters  0 to 65535 1  16BCh CANOpen communication speed P186 R/W 00: Auto 01: 10Kbps 02: 20Kbps 03: 50Kbps 04: 125Kbps 05: 250Kbps 06: 500Kbps 07: 800Kbps 08: 1Mbps 16C0h CompoNet node address P190 R/W 0 to 63  16C2h DeviceNet node address P192 R/W 0 to 63  16C5h ML2 frame length P195 R/W 00: 32 bytes 01: 17 bytes  16C6h ML2 node address P196 R/W 21 to 3E  4-215 4-4 Communication Function * Data on H003 (Motor capacity selection) is the following code data. Code data 00 01 02 03 04 05 06 07 08 09 10 Motor capacity (kW) 0.2  0.4  0.75  1.5 2.2  3.7  Code data 11 12 13 14 15 16 17 18 19 20 21 Motor capacity (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Code data 22 23 24 25 26 Motor capacity (kW) 90 110 132 150 160 Register No. Function name 2103h R/W F202 (HIGH) R/W 2nd acceleration time 1 2104h F202 (LOW) R/W 2105h F203 (HIGH) R/W 2nd deceleration time 1 2106h 2107h to 2202h Not used F203 (LOW) R/W   Monitor and setting parameters Resolution 0.01 to 3600.00 0.01 [s] 0.01 to 3600.00 0.01 [s]  Register No. Function name Function code R/W Monitor and setting parameters Resolution 2203h 2nd set base frequency A203 R/W 30 to 2nd Max. frequency 1 [Hz] 2204h 2nd maximum frequency A204 R/W 30 to 400 1 [Hz] 2205h to 2215h Not used   A220 (HIGH) R/W 2216h 2nd multi-step speed reference 0 2217h  0.00 to 2nd Max. frequency A220 (LOW) R/W   0.01 [Hz] 2218h to 223Ah Not used 223Bh 2nd torque boost selection A241 R/W 00: Manual torque boost 01: Automatic torque boost 223Ch 2nd manual torque boost voltage A242 R/W 0.0 to 20.0 0.1 [%] 223Dh 2nd manual torque boost frequency A243 R/W 0.0 to 50.0 0.1 [%]   4-216 4 Functions Function code 4-4 Communication Function Register No. 223Eh 2nd V/f characteristics selection 223Fh Not used 2240h Function code R/W Monitor and setting parameters 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) Resolution  A244 R/W   2nd automatic torque boost voltage compensation gain A246 R/W 0 to 255 1 2241h *2nd automatic torque boost slip compensation gain A247 R/W 0 to 255 1 2242h to 224Eh Not used   A261 (HIGH) R/W 4 Functions Function name 224Fh 2nd frequency upper limit 2250h A261 (LOW) R/W 2251h A262 (HIGH) R/W 2nd frequency lower limit A262 (LOW) R/W   A292 (HIGH) R/W 2270h A292 (LOW) R/W 2271h A293 (HIGH) R/W A293 (LOW) R/W 2252h 2253h to 226Eh Not used 226Fh 2nd acceleration time 2 2nd deceleration time 2 2272h 2273h 2nd 2-step acceleration/ deceleration selection 2274h 2nd 2-step acceleration frequency A294 R/W A295 (HIGH) R/W 2275h A295 (LOW) R/W 2276h A296 (HIGH) R/W 2nd 2-step deceleration frequency 2277h 4-217 A296 (LOW) R/W   0.00/2nd frequency lower limit to 2nd Max. frequency 0.01 [Hz] 0.00/Starting frequency to 2nd frequency upper limit 0.01 [Hz]  0.01 to 3600.00 0.01 [s] 0.01 to 3600.00 0.01 [s] 00: 2CH-Terminal (Switched via multifunction input 09) 01: Preset FQ (Switched by setting) 02: FWD-REV (Enabled only when switching forward/reverse)  0.00 to 400.00 0.01 [Hz] 0.00 to 400.00 0.01 [Hz] 4-4 Communication Function Register No. Function name 2278h to 230Bh Not used 230Ch 2nd electronic thermal level 230Dh 2nd electronic thermal characteristics selection Function code R/W   b212 R/W 0.20 x Rated current to 1.00 x Rated current 0.1 [A] R/W 00: Reduced TRQ (Reduced torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting)  b213 Monitor and setting parameters Resolution  4 230Eh to 2501h Not used 2502h 2nd motor parameter selection H202 R/W 00: Standard motor parameter 01: Auto-tuning parameter 02: Auto-tuning parameter (online auto-tuning enabled) 2503h 2nd motor capacity selection H203 R/W 0.20 to 160.0 2504h 2nd motor pole number selection H204 R/W 2/4/6/8/10 Pole H205 (HIGH) R/W 0.001 to 80.000 0.001 H205 (LOW) R/W H206 R/W   H220 (HIGH) R/W  2nd speed response 2506h 2507h 2nd stabilization parameter 2508h to 2514h Not used 2515h 2nd motor parameter R1 2516h H220 (LOW) R/W 2517h H221 (HIGH) R/W 2nd motor parameter R2 2518h H221 (LOW) R/W 2519h H222 (HIGH) R/W 2nd motor parameter L 251Ah H222 (LOW) R/W 251Bh H223 (HIGH) R/W 2nd motor parameter IO 251Ch H223 (LOW) R/W 251Dh H224 (HIGH) R/W 2nd motor parameter J 251Eh H224 (LOW)  0 to 255  0.01 [kW] 1  0.001 to 65.535 0.001 [] 0.001 to 65.535 0.001 [] 0.01 to 655.35 0.01 [mH] 0.01 to 655.35 0.01 [A] 0.001 to 9999.000 0.001 [kgm2] R/W 4-218 Functions 2505h  4-4 Communication Function Register No. 251Fh to 2523h Function name Not used 2524h 2nd motor parameter R1 (auto-tuning data) Functions 4 Function code R/W   H230 (HIGH) R/W 2525h H230 (LOW) R/W 2526h H231 (HIGH) R/W 2nd motor parameter R2 (auto-tuning data) 2527h H231 (LOW) R/W 2528h H232 (HIGH) R/W 2nd motor parameter L (auto-tuning data) 2529h H232 (LOW) R/W 252Ah H233 (HIGH) R/W 2nd motor parameter IO (auto-tuning data) 252Bh H233 (LOW) R/W 252Ch H234 (HIGH) R/W 2nd motor parameter J (auto-tuning data) 252Dh H234 (LOW) R/W   Monitor and setting parameters Resolution  0.001 to 65.535 0.001 [] 0.001 to 65.535 0.001 [] 0.01 to 655.35 0.01 [mH] 0.01 to 655.35 0.01 [A] 0.001 to 9999.000 0.001 [kgm2] 252Eh to 253Ch Not used 253Dh 2nd PI proportional gain H250 R/W 0.0 to 1000.0 0.1 [%] 253Eh 2nd PI integral gain H251 R/W 0.0 to 1000.0 0.1 [%] 253Fh 2nd P proportional gain H252 R/W 0.01 to 10.00 0.01 2540h to 2546h Not used   2547h 2nd limit at 0 Hz H260 R/W 0.0 to 100.0 2548h 2nd boost amount at SLV startup, 0 Hz H261 R/W 0 to 50 2549h to 3102h Not used     0.1 [%] 1 [%]  * Data on H203 (2nd motor capacity selection) is the following code data. Code data 00 01 02 03 04 05 06 07 08 09 10 Motor capacity (kW) 0.2  0.4  0.75  1.5 2.2  3.7  Code data 11 12 13 14 15 16 17 18 19 20 21 Motor capacity (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Code data 22 23 24 25 26 Motor capacity (kW) 90 110 132 150 160 4-219 4-4 Communication Function Register No. Function name 3103h Function code R/W F302 (HIGH) R/W 3rd acceleration time 1 3104h F302 (LOW) R/W 3105h F303 (HIGH) R/W 3rd deceleration time 1 3106h 3107h to 3202h Not used F303 (LOW) R/W   Monitor and setting parameters Resolution 0.01 to 3600.00 0.01 [s] 0.01 to 3600.00 0.01 [s] 4  Register No. Function name Function code R/W Monitor and setting parameters Resolution 3203h 3rd set base frequency A303 R/W 30 to 3rd Max. frequency 1 [Hz] 3204h 3rd maximum frequency A304 R/W 30 to 400 1 [Hz]   A320 (HIGH) R/W 3205h to 3215h Not used 3216h 3rd multi-step speed reference 0 3217h 3218h to 323Bh Not used  0.00 to 3rd Max. frequency A320 (LOW) R/W   0.01 [Hz]  323Ch 3rd manual torque boost voltage A342 R/W 0.0 to 20.0 0.1 [%] 323Dh 3rd manual torque boost frequency A343 R/W 0.0 to 50.0 0.1 [%] 323Eh 3rd V/f characteristics selection A344 R/W 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics)   A392 (HIGH) R/W 326Eh A392 (LOW) R/W 326Fh A393 (HIGH) R/W A393 (LOW) R/W   b312 R/W 323Fh to 326Ch Not used 326Dh 3rd acceleration time 2 3rd deceleration time 2 3270h 3271h to 330B 330Ch Not used 3rd electronic thermal level   0.01 to 3600.00 0.01 [s] 0.01 to 3600.00 0.01 [s]  0.20 x Rated current to 1.00 x Rated current 0.1 [A] 4-220 Functions 4-4 Communication Function Register No. 330Dh 330Eh to 3506h 3rd electronic thermal characteristics selection Not used 3507h 3rd stabilization parameter From 3508h Not used Functions 4 Function name 4-221 Function code R/W b313 R/W   H306 R/W   Monitor and setting parameters 00: Reduced TRQ (Reduced torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting) Resolution   0 to 255 1  Chapter 5 Maintenance Operations 5-1 Protective Functions and Troubleshooting ... 5-1 5-2 Warning Function............................................. 5-10 5-1 Protective Functions and Troubleshooting 5Maintenance Operations 5-1 Protective Functions and Troubleshooting Error Code List Name Maintenance Operations 5 Description If the motor is restrained or rapidly accelerated or decelerated, a large current flows through the Inverter, which results in a malfunction. The current exceeding the specified level shuts off the output Overcurrent and an error trip appears. This protection function detects an overcurrent through the AC CT (current detector). The protection circuit is activated at approximately 220% of the Inverter rated output current and a trip occurs. Overload trip *1 Braking resistor overload trip 5-1 Error Code Points to check and remedy Reference page Constant speed E01.0 Is there any rapid load fluctuation? (Eliminate load fluctuation.) Is there any output short-circuit? (Check the output wires.) Is there any ground fault? (Check the output wires and motor.) Deceleration E02.0 Is there any rapid deceleration? (Increase the deceleration time.) 4-8 4-37 E03.0 Is there any rapid acceleration? (Increase the acceleration time.) Has the motor shaft been locked? (Check the motor and wires.) Is the torque boost too high? (Lower the torque boost.) 4-8 4-37 E04.0 Is the DC injection braking too high? (Lower the injection breaking.) Is there any error on CT? (Replace or repair the CT.) 4-24 E05.0 Is the load too large? (Reduce the loading factor.) Is the thermal level correct? (Adjust the thermal level to an appropriate level.) Note: The electronic thermal function is set to work easily at 5 Hz or lower. If a large load inertial moment is applied, the overload protect function works when the motor starts accelerating, and the load prevents it from accelerating. In this case, increase the torque boost or take other measures for adjustment. 4-46 E06.0 Is there any rapid deceleration? (Increase the deceleration time.) Is the operation cycle frequent? (Decrease the number of operation cycles.) Is the usage rate setting of the regenerative braking function low? (Set to an appropriate level.) Note: Pay attention to the allowable power of the resistor. 4-8 4-74 Acceleration Others Monitors the Inverter output current and shuts off the output, displaying an error if the built-in electronic thermal function detects overload against the motor. Trips depending on the electronic thermal function settings. Shuts off the output and displays an error if the usage rate of regenerative braking circuit exceeds the b090 set value.  5-1 Protective Functions and Troubleshooting Name Overvoltage trip EEPROM error *2 *3 Description Extremely high DC voltage between P/+ and N/- may result in failure. This function therefore shuts off the output and displays an error if the DC voltage between P/+ and N/- exceeds the specified level because of regenerative energy from the motor or increase of the incoming voltage during operation. Trips when the DC voltage between P/+ and N/- reaches approximately 400 V DC for 200-V class, and 800 V DC for 400-V class. Reference page Points to check and remedy E07.0 Is there any rapid deceleration? (Increase the deceleration time.) Is there any ground fault? (Check the output wires and motor.) Has the motor been rotated/driven from the load side? (Reduce regenerative energy.) E08.0 Is there any large electrical noise source around? (Countermeasures against electrical noise) Has the cooling efficiency been reduced? (Check that there is no clogging in the cooling fan and fin, if so clean it.) (Replace the cooling fan if faulty.)  5  *1. The reset command is not accepted until approximately 10 seconds after the trip occurs (protection function works). *2. The reset command is not accepted if the EEPROM error E08.0 occurs. Turn off the power once. If you find E08 when turning on the power again, it is possible that the internal memory element of the drive has been damaged or the parameters have not been memorized correctly. Perform the user initialization to set the parameters again. *3. The reset command through the RS terminal or STOP/RESET key is not accepted. Turn off the power. Description Undervoltage trip Shuts off the output if the incoming supply voltage drops below the specified level. This is because the control circuit stops working properly when the incoming supply voltage to the Inverter drops. Trips when the DC voltage between P/+ and N/- drops to approximately 175 V DC for 200-V class, and 345 V DC for 400-V class. E09.0 Has the power supply voltage decreased? (Check the incoming power supply.) Is the power supply capacity sufficient? (Check the power supply.) Has the drives internel charge circuit thyristor been damaged? (Check the thyristor.) CT error Shuts off the output if an error occurs in the CT (current detector) built into the Inverter. Trips if the CT output is approximately 0.6 V or more when the power is turned on. E10.0 The Inverter has a fault. (Repair/Replace)  E11.0 Is there any large electrical noise source around? (Countermeasures against noise) The Inverter has a fault. (Repair/Replace)  CPU error *1 Shuts off the output and displays an error if the internal CPU has worked erroneously or abnormally. Note: If an abnormal value is read from EEPROM, it may become a CPU error depending on the case. Error Code Check point and remedy Reference page Name 4-28 *1. The reset command through the RS terminal or STOP/RESET key is not accepted. Turn off the power. *2. The reset operation via the Digital Operator is not accepted. Be sure to reset via the RS terminal. 5-2 Maintenance Operations Shuts off the output and displays an error if an error occurs in the built-in EEPROM because of external noise or abnormal temperature rise. Note: This may be a CPU error depending on the case. Error Code 5-1 Protective Functions and Troubleshooting Name 5 External trip If an error occurs in the external equipment or devices, the Inverter receives an input signal, then the drives output is shut off. (Available with the external trip function selected) USP trip Appears when the power is turned on with the RUN signal input into the Inverter. (Available with the USP function selected) Ground fault trip *1 Maintenance Operations Description Protects the Inverter if a ground fault between the Inverter output unit and the motor is detected when turning on the power. (This function does not work when there is residual voltage in the motor.) Appears if the incoming voltage continues to be higher than the specification value for 100 seconds Incoming while the Inverter is stopped. overvoltage Trips when the main circuit DC trip voltage reaches approximately 390 V DC for 200-V class, and 780 V DC for 400-V class. Shuts off the output when a momentary power interruption occurs for 15 ms or more. Momentary If the shutoff time is long, it is power normally recognized as a power interruption shutoff. Note that, when restart is trip selected, the Inverter restarts at power-on as long as the RUN command remains. Temperature error when the rotation speed of the cooling fan decreases Appears if a decrease of the cooling fan rotation speed has been detected when a temperature error occurs. Temperature error Shuts off the output if the temperature has risen in the main circuit because of the high ambient temperature. Gate array Trips when a fault is detected in communicommunication behavior between cations the built-in CPU and the gate array. error Error Code Check point and remedy Reference page E12.0 Has any error occurred in the external devices when the external trip function is selected? (Correct the external device error.) 4-84 E13.0 When the USP function was selected, did you turn on the power with the RUN signal input into the Inverter? (Cancel the RUN command and turn on the power.) 4-84 E14.0 Is there any ground fault? (Check the output wires and motor.) Is there any error in the Inverter itself? (Disconnect the output wires to check.) Is there any error in the main circuit? (Check the main circuit. Refer to Chapter 6.) (Repair/Replace)  E15.0 Is the incoming supply voltage too high while the Inverter is stopped? (Lower the incoming voltage, correct the power supply fluctuation. Fit an AC reactor to power supply input if needed.)  E16.0 Has the incoming power supply voltage dropped? (Power recovery) Is there a contact failure for MCCB and/or Mg? (Replace MCCB, Mg.) 4-60 E20.0 Has the cooling efficiency been reduced? (Replace the cooling fan.) Is there any clogging in the heatsink fin? (Clean the fin.)  E21.0 Have you installed the Inverter vertically? (Installation check) Is the ambient temperature high? (Decrease the ambient temperature.)  E23.0 Is there any large electrical noise source around? (Countermeasures against electrical noise) Has any internal cable been disconnected? (Check the connector.)  *1. The reset command through the RS terminal or STOP/RESET key is not accepted. Turn off the power. *2. The reset operation via the Digital Operator is not accepted. Be sure to reset via the RS terminal. 5-3 5-1 Protective Functions and Troubleshooting Name Error Code Check point and remedy Reference page E24.0 Is there any input power supply phase loss? (Check the input wiring.) Is there a contact failure for MCCB and/or Mg? (Replace MCCB, Mg.)  E25.0 Is there any large electrical noise source around? (Countermeasures against electrical noise) Has the main element/IGBT been damaged? Is there any output short-circuit? (Check the IGBT.) The Inverter has a failure. (Repair/ Replace)  E30.0 Is there any output short-circuit? (Check the output wires.) Is there any ground fault? (Check the output wires and motor.) Has the main element been damaged? (Check the IGBT.) Is there any clogging in the fin? (Clean the fin.)  E35.0 Is the motor temperature too high? (Check the motor temperature.) Is there any damage to the thermister inside the motor? (Check the thermistor.) Is there any electrical noise being introduced in the thermister signal? (Separate the wiring.) 2-9 4-75 E36.0 Is the brake ON/OFF function working? (Brake check) Is the set time for b124 too short? (Increase b124.) Has the brake confirmation signal been input? (Wiring check) 4-76 Shuts off the hardware output and displays an error when the EMR terminal (S3) is turned on with SW1 on the logic board ON. E37.0 Did any error occur in the external devices when the emergency shutoff function was selected? (Correct the external device error.) 2-9 If an overload is detected in the lowest speed range of 0.2 Hz max., an electronic thermal trip inside the Inverter works to shut off the Inverter output. (2nd electronic thermal) (However, a higher frequency could remain in the error history.) E38.0 Is the load too large? (Reduce the loading factor.)  E41.0 Is the communication speed correct? Is the wiring distance appropriate? (Connection check) Description Prevents Inverter damage due to input phase loss when the input Input open phase loss protection selection is phase trip enabled (b006=01), and trips. Trips when the phase loss time is approximately 1 s or more. Trips when the gate array cannot confirm IGBT ON/OFF because of a Main circuit main element failure, a load short error circuit, or an erroneous operation *1 resulting from radiated electrical noise. Shuts off the Inverter output when detecting the thermistor resistance Thermistor value inside the motor has changed error which is connected to the TH terminal, resulting motor temperature rise. When 01 is selected in b120 (brake control selection), this error appears if the brake ON/OFF cannot be Brake error confirmed within the b124 set time (brake confirmation wait time) after the Inverter outputs the brake release signal. Emergency shutoff *2 Overload trip in low speed range Appears when the timeout occurs ModBus because of disconnection during communic Modbus-RTU communication. ations error (Trip by the C076 setting) 4-147 *1. The reset command through the RS terminal or STOP/RESET key is not accepted. Turn off the power. *2. The reset operation via the Digital Operator is not accepted. Be sure to reset via the RS terminal. 5-4 Maintenance Operations Shuts off the Inverter output to protect the main element when a momentary overcurrent, temperature error in the main IGBT error element, or drop of the main element driving power supply occurs. (Retry operation cannot be performed for this trip.) 5 5-1 Protective Functions and Troubleshooting Name Description Error Code Reference page Option 1 error Detects an error on the board mounted on option port 1. E60.0 to E69.0 Has the option board been securely mounted? (Check that the mounting is correct.)  Option 2 error Detects an error on the board mounted on option port 2. E70.0 to E79.0 Has the option board been securely mounted? (Check that the mounting is correct.)  Has the incoming power supply voltage dropped? (Power recovery) Is there a contact failure for MCCB and/or Mg? (Replace MCCB, Mg.) Is the voltage between P/+ and N/normal? (Check the voltage between P/+ and N/-.)  COM ERROR Has the remote cable plug been inserted properly? (Check the remote cable inserted correctly.) Has the Digital Operator been inserted properly? (Check the Digital Operator contact.)  Restart Wait In case of zero-start. Shows the waiting status after the incoming Inverter voltage decreases Undervoltage and shuts off. standby This error also appears during momentary power interruption. UV Wait 5 Maintenance Operations Check point and remedy Appears if an error occurs between Communications the Digital Operator and the error Inverter. Retry standby Appears in the restart standby status when the momentary power interruption/trip retry functions are enabled. Power shutoff Appears when the power is shut off. RUN command is limited Appears if the limited RUN command is received while the rotation direction is limited to one direction with b035.  F-adj Wait In case of frequency matching. Power OFF   RUN CMD.  Disable  *1. The reset command through the RS terminal or STOP/RESET key is not accepted. Turn off the power. *2. The reset operation via the Digital Operator is not accepted. Be sure to reset via the RS terminal. 5-5 5-1 Protective Functions and Troubleshooting LCD Digital Operator Error Message Display Check item Action COM ERROR -No signal is received from the inverter within 4 sec. -Reset the inverter. -Check inverter type. -Check the connector for loseness/disconnection. -Check the cable for break. -Avoid issuing the RESET signal continuously for more than 5 sec. -Change the correct inverter type. -Replace the cable and the connector. INV in RUN mode -The WRITE key is pressed while the inverter is running. -Soft-lock is turned ON. -Check if the WRITE key is pressed while the inverter is running. -Check if the WRITE key is pressed while soft-lock is ON. -The WRITE key should be pressed only while the inverter stops. -Release the Soft-Lock (of the inverter). INV in TRIP mode -WRITE key is pressed while inverter trips. -Check if the inverter trips. -Reset the inverter from trip status. INV Type Un-match -An attempt was made writing parameters between different inverter type. - -Writing is possible only between the same type inverters, Read lock enabled -In case of display “READ LOCK“. - -Release the Read Lock. Data Check Sum Error -EEPROM of LCD digital operator is overloaded. It reaches the EEPROM’s Write Limitation. - -If the same error appears after the power is supplied several times, the operator is defective. -The parameters in LCD digital operator and the parameters written into the inverter are unmatched. - INV Check Sum Error -If the same error appears several times, the inverter is defective. (Note) Resetting method Press STOP/ RESET key Supply the power again Note: It will happen sometimes when you try to write data into an inverter with different voltage class and capacity. (Please refer to each inverter instruction manual). 5-6 5 Maintenance Operations Cause 5-1 Protective Functions and Troubleshooting Option Board Protection Function List E6*.(OP1-*) appears when the option board is mounted on option port 1 (Digital Operator connecter side) , and E7*.(OP2-*) appears when it is mounted on option port 2 (control circuit terminal block side). •Protection function list when the PG board (3G3AX-PG01) is mounted Name Error Code Encoder disconnection Shuts off the output and displays an error when the encoder wiring disconnection or connection failure is detected, the encoder is damaged, or an encoder except for line driver output is used. E60.0 E70.0 Excess speed Shuts off the output and displays an error when the motor rotation exceeds the maximum frequency (A004) × the overspeed error detection level (P026). E61.0 E71.0 Positioning error Shuts off the output and displays an error when the current position deviation against the position reference value exceeds 1,000,000 pulses during position control. E62.0 E72.0 Position control range trip Shuts off the output and displays an error when the current position exceeds the setting values of the position limit range specification for Forward (P072) and Reverse (P073) during absolute position control. E63.0 E73.0 3G3AX-PG01 connection error Shuts off the output and displays an error if a connection (mounting) failure of the PG board is detected. E69.0 E79.0 5 Maintenance Operations Description Note: Check the DIP switch settings on the PG board for any abnormal operation. Function List of the DIP Switches on the PG Board (3G3AX-PG01) DIP switch Switch No. Description ON Disconnection detection enabled when the encoder A/B-phase is not connected OFF Disconnection detection disabled when the encoder A/B-phase is not connected ON Disconnection detection enabled when the encoder Z-phase is not connected OFF Disconnection detection disabled when the encoder Z-phase is not connected ON With the termination resistor between SAP and SAN (150 ) OFF Without the termination resistor between SAP and SAN ON With the termination resistor between SBP and SBN (150 ) OFF Without the termination resistor between SBP and SBN 1 SWENC 2 1 SWR 2 •Protection function display when the digital command board (3G3AX-DI01) is mounted Name 3G3AX-DI01 error Description Shuts off the output and displays an error if a timeout occurs in communication between the Inverter and digital command board. Error Code E60.0 E70.0 Note: Input mode is determined by the combination of DIP and rotary switches. Check the settings of the DIP and rotary switches on the digital command board for any abnormal operation. 5-7 5-1 Protective Functions and Troubleshooting Function List of the DIP and Rotary Switches on the digital command board (3G3AX-DI01) DIP switch (TYPE) Switch No. 1 2 Resolution setting Rotary switch (CODE) Setting code 0.01 Hz 0  1 OFF: Batch input mode (PAC) Acceleration/Deceleration time setting Set frequency 0.1 Hz 1 Hz Rate 0.01 sec 0.1 sec 1 sec Torque limit setting Position setting 1% 1 pulse  2  3  4  5 For factory adjustment (Do not set) 6 OFF: Binary input (BIN) 7 to F For factory adjustment (Do not set) 0  1   2  3 ON: Dividing input mode (DIV)  4   5  6  7     8  9  A   B  C to F For factory adjustment (Do not set) How to Read the Input Mode List Example 1. Switch setting when setting the frequency with a resolution of 1 Hz, via binary input (BIN) in the batch input mode (PAC) TYPE CODE 1 2 OFF: BIN OFF: PAC 2 Example 2. Switch setting when setting the frequency with a resolution of 0.1 Hz, via BCD input, and setting the acceleration/deceleration time with a resolution of 0.1 sec, via BCD input in the dividing input mode (DIV) TYPE CODE 1 2 ON: BCD ON: DIV 4 For the communication option boards, refer to the specific user manual of each option. 5-8 5 Maintenance Operations ON: BCD input (BCD)  5-1 Protective Functions and Troubleshooting Trip Monitor Display (1) Trip factor Explanation of display TRIP M1-STOP ALL E 12.1 E 12.1 E12.1 Indicates the cause of the trip. Indicates the Inverter status at the time of tripping. 50.00Hz Ext. Trip 111006 11:05 Stop (2) Output frequency (Hz) at the time of tripping 4.00A TRIP ERR1 P1 5 M1-STOP ALL Ext. Trip 111006 11:05 Stop Output FQ 50.00Hz Maintenance Operations Output current TRIP ERR1 P2 DC Voltage (3) Output current (A) at the time of tripping 4.00A M1-STOP ALL 400.2 Vdc (4) P-N DC voltage (V) at the time of tripping 15hr (5) Total RUN time (h) before the trip Ext. Trip 400.2Vdc RUN time 15hr ON time 8hr 8hr (6) Total power ON time (h) before the trip 5-9 0 1 2 3 4 5 6 7 8 9 : During initialization at power-on or with the reset terminal set to ON. : During stop : During deceleration : During constant speed : During acceleration : The RUN command is turned on at frequency: 0. : During startup : During DC injection braking : During overload limit : During forcing/servo ON Note: The trip monitor display shows the Inverter status at the time of tripping, not the actual motor operation. (Example) While PID control is used or the frequency reference is input using analog signals (voltage/current), the Inverter may alternate frequently between acceleration and deceleration because of the signal fluctuations, even if the motor seems to operate at a constant speed. In this case, the onscreen lnverter status at the time of tripping may differ from the actual operation. 5-2 Warning Function 5-2 Warning Function •The following table shows the details of warning display and parameter correction. Target code Frequency upper limit A061/A261 Base code > Frequency lower limit A062/A262 Base frequency A003/A203/A303 Condition > *1 > > Multi-step speeds 1 to 15 A021 to A035 > Orientation speed setting P015 > Frequency lower limit A062/A262 > Output frequency F001, Multi-step speed reference 0 A020/A220 *2 > Multi-step speeds 1 to 15 A021 to A035 > < Frequency upper limit A061/A261 Maximum frequency A004/A204/A304 5 Frequency upper limit A061/A261 Maintenance Operations Output frequency F001, Multi-step speed reference 0 A020/A220/A320 *2 Orientation speed P015 < Output frequency F001, Multi-step speed reference 0 A020/A220/A320 *2 < Frequency upper limit A061/A261 < Frequency lower limit A062/A262 < Output frequency F001, Multi-step speed reference 0 A020/A220/A320 *2 < Multi-step speeds 1 to 15 A021 to A035 < Jogging frequency A038 < Output frequency F001, Multi-step speed reference 0 A020/A220/A320 *2 Multi-step speeds 1 to 15 A021 to A035 Frequency upper limit A061/A261 > Frequency lower limit A062/A262 > Output frequency F001, Multi-step speed reference 0 A020/A220 *2 > Multi-step speed reference 1 to 15 A021 to A035 > Free V/f frequencies 1 to 6 b100, b102, b104, b106, b108, b110 > Free V/f frequencies 2 to 6 b102, b104, b106, b108, b110 < Free V/f frequency 1 b100 > Free V/f frequencies 3 to 6 b104, b106, b108, b110 < Free V/f frequencies 1, 2 b100, b102 > Free V/f frequencies 4 to 6 b106, b108, b110 < Frequency lower limit A062/A262 Starting frequency b082 Jump frequency 1/2/3 ± Jump width A063 ± A064 A065 ± A066 A067 ± A068 *3 Free V/f frequency 7 b112 Free V/f frequency 1 b100 Free V/f frequency 2 b102 Free V/f frequency 3 b104 5-10 5-2 Warning Function Target code Condition Base code Free V/f frequencies 1 to 3 b100, b102, b104 > Free V/f frequencies 5, 6 b108, b110 < Free V/f frequencies 1 to 4 b100, b102, b104, b106 > Free V/f frequency 6 b110 < Free V/f frequencies 1 to 5 b100, b102, b104, b106, b108 > Free V/f frequency 6 b110 Free electric thermal frequencies 2, 3 b017, b019 < Free electric thermal frequency 1 b015 Free electric thermal frequency 1 b015 > Free electric thermal frequency 3 b019 < Free electric thermal frequencies 1 2 b015, b017 > Free V/f frequency 4 b106 Free V/f frequency 5 b108 Maintenance Operations 5 Free electric thermal frequency 2 b017 Free electric thermal frequency 3 b019 *1. In this case, the base frequency is rewritten when corresponding parameters. Change the data to a correct value is a warning occurs. Otherwise, the motor may burn out depending on the value. *2. Checks even if the frequency reference selection (A001) is set other than to the Digital Operator (02). *3. The jump frequency is rewritten into the value of the subtraction of the jump width (lower limit) from the jump frequency. • Warning appears when a target code set data meets the condition shown above in relation to the base code data. • Parameters are rewritten into the data of the base code. (rewritten at start-up) 5-11 Chapter 6 Inspection and Maintenance 6-1 Inspection and Maintenance ........................... 6-1 6-1 Inspection and Maintenance 6Inspection and Maintenance 6-1 Inspection and Maintenance DANGER Do not change wiring and slide switches (SW1), put on or take off Digital Operator and optional devices, replace cooling fans while the input power is being supplied. Doing so may result in a serious injury due to an electric shock. Do not remove the terminal block cover during the power supply and 10 minutes after the power shutoff. Doing so may result in a serious injury due to an electric shock. CAUTION 6 Inspection and Maintenance Do not touch the Inverter fins, braking resistors and the motor, which become too hot during the power supply and for some time after the power shutoff. Doing so may result in a burn. Do not dismantle, repair or modify this product. Doing so may result in an injury. Safety Information Maintenance and Inspection •Be sure to confirm safety before conducting maintenance, inspection or parts replacement. Precautions for Use Operation Stop Command •Provide a separate emergency stop switch because the STOP key on the Digital Operator is valid only when function settings are performed. •When checking a signal during the power supply and the voltage is erroneously applied to the control input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal. Product Disposal •Comply with the local ordinance and regulations when disposing of the product. 6-1 6-1 Inspection and Maintenance Daily Inspection •Basically, check the following during operation. •The motor operates according to the settings. •There are no errors in the installation environment. •There are no errors in the cooling system. •There are no abnormal vibrations or sounds. •There are no abnormal overheat or discoloration. •There are no abnormal odors. •Check the input voltage of the Inverter during operation using a tester or other equipment. •There is no frequent power supply voltage fluctuation. •The voltage level between the wires is balanced. Cleaning •Always keep the Inverter clean for operation. •Lightly remove any dirt with a soft cloth moistened with a neutral detergent. Periodic Inspection •Check the parts that cannot be checked without stopping operation, as well as those that require periodic inspection. •Contact OMRON Corporation for periodic inspections. •Check that there are no errors in the cooling system. .......... Clean the air filter. •Check that all parts that need tightening are secure. .......... Screws and bolts may become loose because of vibration or temperature change. •Check that there is no corrosion or damage to the conductors and/or insulators. •Measurement of insulation resistance. •Check and replace the cooling fan, smoothing capacitor, and relay. 6-2 6 Inspection and Maintenance Note: Do not use such solutions as acetone, benzene, toluene, or alcohol for cleaning. Doing so may cause the Inverter surface to dissolve or its coating to come off. Do not use any detergent or alcohol to clean the Digital Operator display. 6-1 Inspection and Maintenance Daily Inspection and Periodic Inspection Inspection period Inspection part Inspection item Inspection point Periodic Inspection method Criteria Meter Daily 1 year 2 years General Check that there are no abnormal Entire device vibrations or sounds. Power supply voltage 6 Inspection and Maintenance Check ambient Ambient temperature, as environment well as humidity and dust levels. Main circuit General Check that the main circuit voltage is normal. Megger check (between main circuit terminal and ground terminal)  Refer to "2-1 Installation". Ambient temperature 10C to 50C, no freezing. Ambient humidity 90% max., no condensation.  Visual or acoustic inspection No faults  Measure the voltage between Inverter main circuit terminals R/L1, S/L2, and T/L3. Must be within allowable fluctuation of AC voltage.  Disconnect the I/O wirings of the Inverter main circuit terminal block, detach the control terminal block board, and remove the short-circuit bar used for switching the Inverter built-in filter function. Then, use a 5 M min. megger to measure the resistance between the ground terminal and the short-circuited parts of terminals R/L1, S/ L2, T/L3, U/T1, V/T2, W/T3, P/+, PD/+1, N/-, RB, Ro, and To. Thermomet -er Hygrometer Recorder Tester, digital multimeter 500 V DC megger *1. The life of the smoothing capacitor depends on ambient temperature. Refer to "Appendix-2 Product Life Curve" for the replacement reference. *2. The life of the cooling fan varies depending on the environmental conditions, such as ambient temperature and/or dust. Check the operation through daily inspections. *3. The replacement reference (year/cycle) or "Appendix-2 Product Life Curve" is based on the expected design life, which is not guaranteed. 6-3 6-1 Inspection and Maintenance Inspection period Inspection part Inspection item Inspection point Periodic Inspection method Criteria Meter Daily 1 year 2 years General Connection conductor and wire Terminal block  Tighten securely. No faults Check that no part has indications of overheating.  Visual inspection No faults Check that there is no distortion with the conductor.  Visual inspection No faults Visual inspection No faults Disconnect the wiring of the Inverter main circuit terminal block and measure the resistance levels between terminals R/L1, S/L2, T/L3 and P/+, N/-, and between U/T1, V/T2, W/T3 and P/+, N/- in the range of tester × 1 . Refer to "Checking the Inverter and Converter". Inverter unit replacement reference Start/Stop: Cycle 106 *3 Check that there is no damage to the wire Insulation.  Check that there is no damage.  Inverter unit Main circuit Check the Converter resistance unit between the (including terminals. the resistor) Smoothing capacitor Relay  Check that there is no liquid leakage.  Check that the safety valve has not come out and that there are no bulges.  Visual inspection 6 Analog tester Capacity meter No faults Reference of the replacement period: 10 years *2 *3 Check that there is no abnormal sound during operation.  Acoustic inspection No faults Check that there is no rough surface on the contact.  Visual inspection No faults *1. The life of the smoothing capacitor depends on ambient temperature. Refer to "Appendix-2 Product Life Curve" for the replacement reference. *2. The life of the cooling fan varies depending on the environmental conditions, such as ambient temperature and/or dust. Check the operation through daily inspections. *3. The replacement reference (year/cycle) or "Appendix-2 Product Life Curve" is based on the expected design life, which is not guaranteed. 6-4 Inspection and Maintenance Check that any parts which may need tightening are secure. 6-1 Inspection and Maintenance Inspection period Inspection part Inspection item Inspection point Periodic Inspection method Criteria Meter Daily 1 year 2 years Control Operation circuit Protection check circuit 6 Cooling fan Inspection and Maintenance Cooling system Fin Display Check the balance of output voltage levels between phases in single Inverter run. Check that there are no errors in protection and display circuits through sequence protection operation. Check that there are no abnormal vibration or sounds. Meter   Short-circuit or open the Inverter protection Error is found in circuit output under the sequence. simulated conditions. Check that the connection parts are secure.  Rotates Rotate manually smoothly. when the power is off. No faults Reference of the replacement period: 10 years Visual inspection Check that there is no clogging.  Visual inspection No clogging. Visual inspection Check that the LED indicators are lit properly. Check that the LED indicators are lit properly.    Cleaning Display Phase-to-phase voltage balance 200-V class: 4 V max. 400-V class: Digital 8 V max. multimeter Rectifier Voltmeter Measure the voltage between Inverter main circuit terminals U/T1, V/T2, and W/T3. Check that the indicated value is normal.  *2 *3 Clean with a soft cloth. Check the indicated values on the panel meters. The specified or control values Voltmeter, must be ammeter satisfied. *1. The life of the smoothing capacitor depends on ambient temperature. Refer to "Appendix-2 Product Life Curve" for the replacement reference. *2. The life of the cooling fan varies depending on the environmental conditions, such as ambient temperature and/or dust. Check the operation through daily inspections. *3. The replacement reference (year/cycle) or "Appendix-2 Product Life Curve" is based on the expected design life, which is not guaranteed. 6-5 6-1 Inspection and Maintenance Inspection period Inspection part Inspection item Inspection point Periodic Inspection method Criteria Meter Daily 1 year 2 years Check that there are no abnormal vibrations or sounds.  Acoustic, feeling, and/ No faults or visual inspection  Check that there is no abnormal odor No faults caused by damage or overheating. General Check that there are no abnormal odors. Motor Insulation resistance Megger check (Between the collective motor terminals and ground terminal)  Disconnect Inverter main circuit terminals U/T1, V/T2, and W/T3, and shortcircuit the 3-phase motor wires. Then, 5 M min. use a megger to measure the resistance between the motor wire and ground terminal. 500 V DC megger 6 6-6 Inspection and Maintenance *1. The life of the smoothing capacitor depends on ambient temperature. Refer to "Appendix-2 Product Life Curve" for the replacement reference. *2. The life of the cooling fan varies depending on the environmental conditions, such as ambient temperature and/or dust. Check the operation through daily inspections. *3. The replacement reference (year/cycle) or "Appendix-2 Product Life Curve" is based on the expected design life, which is not guaranteed. 6-1 Inspection and Maintenance Megger test •For a megger test of the external circuit, be sure to disconnect all the terminals of the Inverter so as not to apply the test voltage to the Inverter. •Use a high resistance tester for a power distribution test of the control circuit. Do not use a megger or buzzer. •Conduct an Inverter megger test only to the main circuit, not to the control circuit. •Use a 500 V DC megger for a megger test. •For a megger test of the Inverter main circuit, remove the short-circuit bar used for switching the Inverter built-in filter function and then short-circuit terminals R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, PD/+1, P/+, N/-, RB, Ro, and To with the wires, as shown below. After the megger test, remove the short-circuit wires from terminals R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, P/+, PD/+1, N/-, RB, Ro, and To, and reconnect the short-circuit bar for switching the Inverter built-in filter function. Note that the RB terminal is provided only for the Inverters with 22 kW or lower capacity. R/L1 Inspection and Maintenance 6 Power supply Do not connect the power wire. PD/+1 P/+ N/- RB U/T1 S/L2 V/T2 T/L3 W/T3 Motor IM Ground terminal Ground terminal Ro Do not connect to the To motor. 500 V DC megger Be sure to remove the short-circuit bar for switching the built-in filter function. Withstand Voltage Test Do not conduct a withstand voltage test on any part of the Inverter. Doing the test is dangerous and may cause damage or deterioration to the parts inside the Inverter. Checking the Inverter and Converter •The quality of the Inverter and converter can be checked using a tester. (Preparation) Disconnect the externally connected power supply wires (R/L1, S/L2, T/L3), the motor connection wires (U/T1, V/T2, W/T3), and the regenerative braking resistance (P/+, RB). Prepare a tester. (Usable range is 1  measurement resistance.) (Checking method) •The quality can be judged by measuring the conduction state of Inverter main circuit terminal blocks R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, RB, P/+, and N/- while alternating the tester polarity. Note 1: Before checking, measure the voltage between P/+ and N/- at DC voltage range in advance, and confirm that the smoothing capacitor is sufficiently discharged. 6-7 6-1 Inspection and Maintenance Note 2: A nearly infinite value is shown in a no-conduction state. However, the value may not be infinite if the momentary conduction occurs through the influence of the smoothing capacitor The value shown ranges from a few to a few dozen  in a conduction state. The Inverter or converter is in good shape if the values from various parameters are nearly equal, though they are not consistent depending on the types of elements or testers. Note 3: The regenerative braking circuit is provided for Inverters with a capacity of 22 kW or lower. Tester polarity Measurement value + (red) - (black) R/L1 Converter unit S/L2 RB Inverter unit TR1 PD/+1 No conduction D1 PD/+1 PD/+1 P/+ R/L1 D1 D2 Conduction TR2 TR3 D3 U/T1 PD/+1 No conduction R/L1 D2 Converter unit PD/+1 T/L3 S/L2 Conduction V/T2 S/L2 PD/+1 No conduction D3 PD/+1 T/L3 Conduction R/L1 N/- Conduction N/- R/L1 No conduction S/L2 N/- Conduction N/- S/L2 No conduction T/L3 N/- Conduction N/- T/L3 No conduction U/T1 P/+ No conduction P/+ U/T1 Conduction V/T2 P/+ No conduction P/+ V/T2 Conduction W/T3 P/+ No conduction P/+ W/T3 Conduction U/T1 N/- Conduction N/- U/T1 No conduction V/T2 N/- Conduction N/- V/T2 No conduction W/T3 N/- Conduction N/- W/T3 No conduction RB P/+ No conduction P/+ RB Conduction RB N/- No conduction N/- RB No conduction C W/T3 T/L3 TR7 6 D4 D4 D5 D6 TR5 TR6 Inspection and Maintenance TR4 D5 N/- Regenerative braking circuit D6 TR1 Inverter unit TR2 TR3 TR4 TR5 Regenerative braking circuit TR6 TR7 6-8 6-1 Inspection and Maintenance Measurement Methods of I/O Voltage, Current, and Electric Power Below is a general measurement device for input/output voltages, current, and electric power. R W11 IR R/L1 U/T1 ER IS S/L2 W12 V/T2 Inspection and Maintenance 6 Motor EV IT T/L3 W13 W/T3 W02 IW ET Measurement item V IV ES T U EU Inverter Power S supply W01 IU W EW Measurement point Measurement device Note Measurement value reference Power supply voltage EIN Between R-S, S-T, and TR (ER), (ES), (ET) Moving-iron voltmeter or Rectifier voltmeter All effective values 200-V class: 200 to 240 V, 50/60 Hz 400-V class: 380 to 480 V, 50/60 Hz Power supply current IIN Current R, S, T (IR), (IS), (IT) Moving iron ammeter All effective values When the input current is not balanced IIN = (IR+IS+ IT)/3 Input electric power WIN Between R-S, S-T, and T-R (WI1) + (WI2) + (WI3) All effective values Three-wattmeter method Input power factor PfIN Calculated from the measured values of power supply voltage EIN, power supply current IIN, and input electric power WIN. PfIN = Output voltage EOUT Between U-V, V-W, W-U (EU), (EV), (EW) Output current IOUT Current U, V, W (IU), (IV),(IW) Output power WOUT Between U-V, V-W (WO1)+(WO2) Output power factor PfOUT 6-9 Electrodynamic wattmeter WIN 3 ⋅ EIN ⋅ IIN × 100(%) Effective See the figure below value of or fundamental Rectifier voltmeter wave Moving iron ammeter Electrodynamic wattmeter All effective values All effective values Calculated from the measured values of output voltage EOUT, output current IOUT, and output power WOUT. PfOUT = WOUT × 100(%) 3EOUTIOUT Two-wattmeter method (or three-wattmeter method) 6-1 Inspection and Maintenance Inverter Note 1: For output voltage, use Measurement Method of Output Voltage a measurement device that displays effective U R R/L1 U/T1 values of fundamental wave. For current and V S Motor Power supply electric power, use a V/T2 S/L2 measurement device W T that displays all T/L3 W/T3 effective values. 2 W 220 kW Note 2: The Inverter output Diode waveform, under PWM + 600 V 0.1 A min. (200-V class) control, has a margin of 1000 V 0.1 A min. (400-V class) VDC error, especially at a Moving coil type low frequency. 300 V (200-V class) Effective value of fundamental wave VAC 600 V (400-V class) Note 3: General-purpose VAC = 1.1 × VDC testers are not applicable because of noise in many cases. 6 Inspection and Maintenance 6-10 Chapter 7 Specifications 7-1 Standard Specification List ............................. 7-1 7-2 Dimensional Drawing....................................... 7-7 7-3 Options.............................................................. 7-15 7-1 Standard Specification List 7Specifications 7-1 Standard Specification List Three-phase 200-V Class Class 3-phase 200 V Model name (3G3RX-) A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 Max. applicable motor 4P at CT 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 at VT 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 at CT 1.0 1.7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 at VT 1.3 2.1 3.2 4.1 6.7 10.4 15.2 20.0 26.3 29.4 at CT 1.2 2.0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 at VT 1.5 2.6 3.9 5.0 8.1 12.4 18.2 24.1 31.5 35.3 kW 200 V Rated output capacity (kVA) 240 V Rated input voltage 3-phase (3-wire) 200 V -15% to 240 V +10%, 50/60 Hz ±5% Rated output voltage 7 Rated output current (A) 3-phase: 200 to 240 V (Cannot exceed that of incoming voltage.) at CT 3.0 5.0 7.5 10.5 16.5 24 32 46 64 76 at VT 3.7 6.3 9.4 12 19.6 30 44 58 73 85 6 6 14 14 Specifications Radio noise filter Weight (kg) Built-in 3.5 Regenerative braking Braking 7-1 Minimum connection resistance () 3.5 3.5 3.5 3.5 6 Built-in braking resistor circuit (discharge resistor separately mounted) 50 50 35 35 35 16 10 10 7.5 7.5 7-1 Standard Specification List Class 3-phase 200 V Model name (3G3RX-) Max. applicable motor 4P kW 200 V Rated output capacity (kVA) 240 V A2220 at CT 22 30 37 45 55 at VT 30 37 45 55 75 at CT 32.9 41.9 50.2 63.0 76.2 at VT 39.1 49.5 59.2 72.7 93.5 at CT 39.4 50.2 60.2 75.6 91.4 at VT 46.9 59.4 71.0 87.2 112.2 3-phase (3-wire) 200 V -15% to 240 V +10%, 50/ 60 Hz ±5% Rated input voltage 3-phase: 200 to 240 V (Cannot exceed that of incoming voltage.) Rated output voltage Rated output current (A) A2300 A2370 A2450 A2550 at CT 95 121 145 182 220 at VT 113 140 169 210 270 30 43 Radio noise filter Weight (kg) Built-in 14 22 30 Regenerative braking Built-in braking resistor circuit Regenerative braking unit separately mounted Minimum connection resistance () 5  7 Braking Specifications 7-2 7-1 Standard Specification List Three-phase 400-V Class Class 3-phase 400 V Model name (3G3RX-) A4004 A4007 A4015 A4022 A4040 A4055 A4075 A4110 A4150 A4185 Max. applicable motor 4P at CT 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 at VT 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 at CT 1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 at VT 1.3 2.1 3.3 4.6 7.7 11.0 15.2 20.9 25.6 30.4 at CT 1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 at VT 1.5 2.5 4.0 5.5 9.2 13.3 18.2 24.1 30.7 36.5 kW 400 V Rated output capacity (kVA) 480 V Rated input voltage 3-phase (3-wire) 380 V -15% to 480 V +10%, 50/60 Hz ±5% Rated output voltage Rated output current (A) 3-phase: 380 to 480 V (Cannot exceed that of incoming voltage.) at CT 1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 at VT 1.9 3.1 4.8 6.7 11.1 16 22 29 37 43 6 6 14 14 24 24 Radio noise filter Built-in Weight (kg) Specifications 7 3.5 3.5 Regenerative braking Braking Minimum connection resistance () 3.5 3.5 6 Built-in braking resistor circuit (discharge resistor) 100 100 100 100 Class 70 70 kW 400 V Rated output capacity (kVA) 480 V 35 A4220 A430 0 A437 0 A445 0 A455 0 B475 0 B490 0 at CT 22 30 37 45 55 75 90 110 132 at VT 30 37 45 55 75 90 110 132 160 at CT 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1 at VT 39.4 48.4 58.8 72.7 93.5 110.8 135 159.3 200.9 at CT 39.9 48.2 62.3 75.6 93.1 128.3 146.3 180.4 216.1 at VT 47.3 58.1 70.6 87.2 112.2 133 162.1 191.2 241.1 Rated input voltage Rated output current (A) B411K B413K 3-phase (3-wire) 380 V -15% to 480 V +10%, 50/60 Hz ±5% Rated output voltage 3-phase: 380 to 480 V (Cannot exceed that of incoming voltage.) at CT 48 58 75 91 112 149 176 217 260 at VT 57 70 85 105 135 160 195 230 290 60 60 80 80 Radio noise filter Weight (kg) Regenerative braking Built-in 14 22 30 30 30 Built-in braking resistor circuit Regenerative braking unit separately mounted 20  Braking Minimum connection resistance () 7-3 35 3-phase 400 V Model name (3G3RX-) Max. applicable motor 4P 3.5 7-1 Standard Specification List Common Specifications Item Specifications Enclosure rating IP20 up to 55KW, IP00 from 75 to 132KW Cooling method Forced air cooling Control method Phase-to-phase sinusoidal modulation PWM Output frequency range 0.1 to 400 Hz Frequency precision Digital command: ±0.01% of the max. frequency Analog command: ±0.2% of the max. frequency (25C ± 10C) Frequency resolution Digital setting: 0.01 Hz Analog setting: Max. frequency/4000 (Terminal O: 12 bits/0 to +10 V), (Terminal O2: 12 bits/-10 to +10 V), (Terminal OI: 12 bits/0 to +20 mA) Voltage/Frequency characteristics Speed fluctuation Overload current rating Acceleration/Deceleration time V/f optionally changeable at base frequencies of 30 to 400 Hz, V/f braking constant torque, reduction torque, sensor-less vector control, sensor-less vector control at 0 Hz ±0.5% (under sensor-less vector control or sensor-less vector control at 0 Hz) 150%/60s, 200%/3s for CT and 120%/60s for VT 0.01 to 3600.0 s (line/curve selection) 200%/0.3 Hz (under sensor-less vector control or sensor-less vector control at 0 Hz) 7 Starting torque 150%/Torque at 0 Hz (under sensor-less vector control at 0 Hz, when a motor size one rank lower than specified is connected) Forward or reverse operation/Stop Frequency settings Input Operates when the starting frequency is lower than that in deceleration via the STOP command, when the frequency reference is lower than the operation frequency, or via an external input (braking power, time, and frequency are variable) Standard Digital Operator Setting via External signal 0 to +10 V DC, -10 to +10 V DC (Input impedance: 10 k) 4 to 20 mA (Input impedance: 100 ) External port keys Setting through RS485 communication Standard Digital Operator RUN/STOP (Forward/reverse switched via the parameter settings) External signal Forward/Stop (Reverse/Stop available at the time of multi-functional input terminal allocation) 3-wire input available (at the time of control circuit terminal block allocation) External port Setting through RS485 communication 7-4 Specifications DC injection braking 7-1 Standard Specification List Item Thermistor input terminal 1 terminal (Positive/Negative temperature coefficient of resistance element switchable) Multi-function output 5 open collector output terminals: NO/NC switchable, sink/source logic switchable 1 relay (SPDT contact) output terminal: NO/NC switchable [Terminal function] 6 functions can be selected from among 45. Signal during RUN (RUN), Constant speed arrival signal (FA1), Over set frequency arrival signal (FA2), Overload warning (OL), Excessive PID deviation (OD), Alarm signal (AL), Set-frequency-only arrival signal (FA3), Overtorque (OTQ), Signal during momentary power interruption (IP), Signal during undervoltage (UV), Torque limit (TRQ), RUN time exceeded (RNT), Power ON time exceeded (ONT), Thermal warning (THM), Brake release (BRK), Brake error (BER), 0-Hz signal (ZS), Excessive speed deviation (DSE), Position ready (POK), Set frequency exceeded 2 (FA4), Set frequency only 2 (FA5), Overload warning 2 (OL2), Analog FV disconnection detection (FVDc), Analog FI disconnection detection (FIDc), Analog FE disconnection detection (FEDc), PID FB status output (FBV), Network error (NDc), Logic operation output 1 (LOG1), Logic operation output 2 (LOG2), Logic operation output 3 (LOG3), Logic operation output 4 (LOG4), Logic operation output 5 (LOG5), Logic operation output 6 (LOG6), Capacitor life warning (WAC), Cooling fan life warning (WAF), Starting contact signal (FR), Fin overheat warning (OHF), Light load detection signal (LOC), Operation ready (IRDY), Forward run (FWR), Reverse run (RVR), Fatal fault (MJA), Window comparator FV (WCFV), Window comparator FI (WCFI), Window comparator FE (WCFE), Alarm codes 0 to 3 (AC0 to AC3) Multi-function monitor output terminal Analog voltage output, Analog current output, Pulse train output (A-F, D-F {multiplied by "n", pulse output only}, A, T, V, P, etc.) Display monitor Output frequency, Output current, Output torque, Frequency conversion value, Trip record, I/O terminal status, Electric power, etc. Other functions V/f free setting (7), Upper/lower frequency limit, Frequency jump, Curve acceleration/ deceleration, Manual torque boost level/break, Energy-saving operation, Analog meter adjustment, Starting frequency, Carrier frequency adjustment, Electronic thermal function, (free setting available), External start/end (frequency/rate), Analog input selection, Trip retry, Restart during momentary power interruption, Various signal outputs, Reduced voltage startup, Overload limit, Initialization value setting, Automatic deceleration at power-off, AVR function, Automatic acceleration/deceleration, Auto tuning (Online/Offline), High-torque multi-motor operation control (sensor-less vector control of two monitors with one Inverter) Input Multi-function input 8 terminals, NO/NC switchable, sink/source logic switchable [Terminal function] 8 functions can be selected from among 61. Reverse (RV), Multi-step speed setting binary 1 (CF1), Multi-step speed setting binary 2 (CF2), Multi-step speed setting binary 3 (CF3), Multi-step speed setting binary 4 (CF4), Jogging (JG), DC injection braking (DB), 2nd control (SET), 2-step acceleration/ deceleration (2CH), Free-run stop (FRS), External trip (EXT), USP function (USP), Commercial switching (CS), Soft lock (SFT), Analog input switching (AT), 3rd control (SET3), Reset (RS), 3-wire start (STA), 3-wire stop (STP), 3-wire forward/reverse (F/R), PID enabled/disabled (PID), PID integral reset (PIDC), Control gain switching (CAS), UP/DWN function accelerated (UP), UP/DWN function decelerated (DWN), UP/DWN function data clear (UDC), Forced operator (OPE), Multi-step speed setting bit 1 (SF1), Multi-step speed setting bit 2 (SF2), Multi-step speed setting bit 3 (SF3), Multi-step speed setting bit 4 (SF4), Multi-step speed setting bit 5 (SF5), Multi-step speed setting bit 6 (SF6), Multi-step speed setting bit 7 (SF7), Overload limit switching (OLR), Torque limit enabled (TL), Torque limit switching 1 (TRQ1), Torque limit switching 2 (TRQ2), P/PI switching (PPI), Brake confirmation (BOK), Orientation (ORT), LAD cancel (LAC), Position deviation clear (PCLR), Pulse train position command input permission (STAT), Frequency addition function (ADD), Forced terminal block (F-TM), Torque reference input permission (ATR), Integrated power clear (KHC), Servo ON (SON), Preliminary excitation (FOC), Analog command on hold (AHD), Position command selection 1 (CP1), Position command selection 2 (CP2), Position command selection 3 (CP3), Zero return limit signal (ORL), Zero return startup signal (ORG), Forward driving stop (FOT), Reverse driving stop (ROT), Speed/Position switching (SPD), Pulse counter (PCNT), Pulse counter clear (PCC), No allocation (no) Output Specifications 7 7-5 Specifications 7-1 Standard Specification List Item Specifications Protective functions Overcurrent protection, Overvoltage protection, Undervoltage protection, Electronic thermal protection, Temperature error protection, Momentary power interruption/Power interruption protection, Input phase loss protection, Braking resistor overload protection, Ground-fault current detection at power-on, USP error, External trip, Emergency shutoff trip, CT error, Communication error, Option error, etc. Operating environment 0.5 to 15 kHz for CT, 0.5 to 12 kHz for VT Ambient/Storage temperature/ Humidity Options Carrier frequency modification range Feedback option Vibration * Location -10C to 50C/-20C to 65C/20% to 90% RH (with no condensation) 3G3RX-A004 to A220 5.9 m/s2 (0.6G), 10 to 55 Hz 3G3RX-A300 to A550, B4750 to B413K 2.94 m/s2 (0.3G), 10 to 55 Hz At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust) Sensor vector control Digital input option 4-digit BCD, 16-bit binary Other options Braking resistor, AC reactor, DC reactor, Digital Operator cables, Noise filter, Braking unit, etc. 7 * Complies with the test method specified in JIS C0040 (1999). Note: Insulation distance complies with UL/CE standards. Specifications 7-6 7-2 Dimensional Drawing 7-2 Dimensional Drawing 3G3RX-A2004/A2007/A2015/A2022/A2037 A4004/A4007/A4015/A4022/A4040 150 130 2-6 HITACHI WARNING LOCAL REMOTE READ WRITE ESC Specifications 7 62 140 6 143 7-7 255 REV 241 FWD 7-2 Dimensional Drawing 3G3RX-A2055/A2075/A2110 A4055/A4075/A4110 210 189 2-7 HITACHI WARNING LOCAL REMOTE READ WRITE ESC 260 REV 246 FWD 7 7 82 13.6 170 Specifications 203 7-8 7-2 Dimensional Drawing 3G3RX-A2150/A2185/A2220 A4150/A4185/A4220 2-7 250 229 HITACHI WARNING LOCAL REMOTE READ WRITE ESC 376 390 83 REV 9.5 FWD Specifications 7 190 7 244 7-9 7-2 Dimensional Drawing 3G3RX-A2300/A4300 2-10 HITACHI WARNING LOCAL REMOTE READ WRITE ESC 540 REV 510 FWD 7 Specifications 10 265 195 310 7-10 7-2 Dimensional Drawing 3G3RX-A2370/A2450 A4370/A4450/A4550 2-12 HITACHI WARNING LOCAL REMOTE READ WRITE REV 550 FWD 520 ESC 7 Specifications 12 300 250 390 7-11 7-2 Dimensional Drawing 3G3RX-A2550 2-12 HITACHI WARNING LOCAL REMOTE READ WRITE REV 700 FWD 670 ESC 7 Specifications 12 380 250 480 7-12 7-2 Dimensional Drawing 3G3RX-B4750/B4900 2-12 HITACHI WARNING LOCAL REMOTE READ WRITE REV 700 FWD 670 ESC Specifications 7 12 300 268 390 7-13 7-2 Dimensional Drawing 3G3RX-B411K/B413K 2-12 HITACHI WARNING LOCAL REMOTE READ WRITE ESC 740 REV 710 FWD 7 Specifications 12 380 270 480 7-14 7-3 Options 7-3 Options Braking Unit (AX-BCR-TE) Dimensional Drawing B S H H1 OVERCURRENT ACTIVE POWER R BUSS+ BUSS R DANGER HIGH VOLTAGE ! B1 7 T Dimensions Specifications Reference B B1 H H1 T S 82.5 40.5 150 138 220 6 130 64.5 205 193 208 6 131 64.5 298 280 300 9 AX-BCR4015045-TE AX-BCR4017068-TE AX-BCR2035090-TE AX-BCR2070130-TE AX-BCR4035090-TE AX-BCR4070130-TE AX-BCR4090240-TE Specifications Specifications Voltage Permanent Reference Peak (5s max) Minimum connectable resistor (Ohms) Superfast fuse F2 (A) 32 4 100 130 47 2.8 125 11 45 33 16 50 17 13 68 51 11 63 AX-BCR4035090-TE 35 26 90 67 8.5 100 AX-BCR4070130-TE 70 52 130 97 5.5 125 AX-BCR4090240-TE 90 67 240 180 3.2 250 Current (A) Brake power (KVA) Current (A) Brake power (KVA) AX-BCR2035090-TE 35 13 90 AX-BCR2070130-TE 70 25 AX-BCR4015045-TE 15 AX-BCR4017068-TE 200V 400V 7-15 7-3 Options Braking Resistor (AX-REMK-IE) Dimensional Drawing AX-REM00K1200/400-IE AX-REM00K2/4/6-IE 7 Specifications Specifications Type Weight Dimensions Resistance ( Power (W) AX-REM00K2070-IE 70 200 AX-REM00K2120-IE 120 200 AX-REM00K2200-IE 200 200 AX-REM00K4075-IE 75 400 AX-REM00K4035-IE 35 400 AX-REM00K4030-IE 30 400 AX-REM00K5120-IE 120 500 AX-REM00K6100-IE 100 600 AX-REM00K6035-IE 35 600 L H M I T KG 105 27 36 94 - 0.2 200 27 36 189 - 0.425 260 27 36 249 - 0.58 320 27 36 309 - 0.73 7-16 7-3 Options AX-REM00K9-IE Specifications Type 7 Weight Dimensions Resistance ( Power (W) AX-REM00K9070-IE 70 900 AX-REM00K9020-IE 20 900 AX-REM00K9017-IE 17 900 L H M I T KG 200 62 100 74 - 1.41 Specifications AX-REM01K9-IE Specifications Type Resistance ( Power (W) AX-REM01K9070-IE 70 1900 AX-REM01K9017-IE 17 1900 7-17 Weight Dimensions L H M I T KG 200 62 100 74 - 1.41 7-3 Options AX-REM02/03K-IE Specifications Type Resistance ( Power (W) AX-REM02K1070-IE 70 2100 AX-REM02K1017-IE 17 2100 AX-REM03K5035-IE 35 3500 AX-REM03K5010-IE 10 3500 Weight Dimensions L H M I T KG 310 100 240 295 210 7 365 100 240 350 210 8 7 AX-REM19/38K-IE Specifications Specifications Type Resistance ( Power (W) AX-REM19K0030-IE 30 19000 AX-REM19K0020-IE 20 19000 AX-REM19K0008-IE 8 19000 AX-REM19K0006-IE 6 19000 AX-REM38K0012-IE 12 38000 Weight Dimensions L H M I T KG 206 350 140 190 50 8.1 306 350 140 290 50 14.5 7-18 7-3 Options Simplified Selection Table for Braking Unit and Braking Resistor Inverter RX@ Max. motor kW Braking resistor unit Braking Unit AX-BCR@ min. resistance  3-pha 0.55 Inverter mounted type (3 %ED, 10 sec max) Type AX- Resist  REM00K1200-IE 200 2004 50 1.1 2007 1.5 2015 200 V (single-/three-phase) REM00K2070-IE 2.2 2022 4.0 2037 5.5 2055 7.5 Braking torque % Type AX- Resist  180 REM00K1200-IE 200 180 100 REM00K2070-IE 70 200 140 REM00K4075-IE 75 130 90 REM00K4035-IE 35 180 75 50 REM00K6035-IE 35 100 REM00K4035-IE 35 16 75 REM00K9017-IE 17 150 55 REM01K9017-IE 17 110 10 11.0 2110 15.0 2150 REM00K6035-IE 35 40 REM02K1017-IE 17 75 REM00K9017-IE 17 55 REM03K5010-IE 10 95 REM03K5010-IE 10 REM19K0008-IE 8 7.5 18.5 2185 22.0 2220 30.0 2300 75 5 37.0 2370 45.0 2450 2070130-TE Specifications REM00K4075-IE 2075 2035090-TE 7 External resistor 10%ED 10 sec max for built-in 5 sec max for Braking Unit 70 35 Built-in Braking torque % 55.0 2550 0.55 4004 65 4 80 6 80 6 60 3 105 3 85 REM19K0006-IE 2.8 2 x REM19K0006-IE 200 REM00K1400-IE 1.1 95 400 4007 200 REM00K1400-IE 400 200 200 100 1.5 4015 REM00K1200-IE 200 190 REM00K2200-IE 200 190 2.2 4022 REM00K2200-IE 200 130 REM00K5120-IE 120 200 4.0 4040 REM00K2120-IE 120 120 REM00K6100-IE 100 140 140 REM00K9070-IE 70 150 REM00K4075-IE 75 100 REM01K9070-IE 70 110 70 5.5 4055 7.5 Built-in 4075 400 V (three-phase) 35 11.0 4110 15.0 4150 REM00K6100-IE 100 50 REM02K1070-IE 70 75 REM00K9070-IE 70 55 REM03K5035-IE 35 110 REM03K5035-IE 35 REM19K0030-IE 30 24 18.5 4185 22.0 4220 30.0 4300 37.0 4370 45.0 4450 55.0 4550 90 20 4750 90.0 4900 110.0 411K 132.0 75 85 4015045-TE 16 REM19K0020-IE 20 4017068-TE 11 REM38K0012-IE 12 95 125 100 4035090-TE 75.0 100 2 x REM19K0020-IE 10 100 3 x REM19K0030-IE 10 75 105 8.5 4070130-TE 5.5 2 x REM38K0012-IE 6 4090240-TE 3.2 3 x REM38K0012-IE 4 125 413K 105 (1) Inverter specifications (choose voltage, capacity, and model) The content noted in the table assumes the case of combining one Inverter and one motor of the same capacity. (2) Select the %ED. Use the %ED that is equivalent to or lower than the value shown. 7-19 7-3 Options (3)Table above just contain typical recommended values that could work correctly in a wide range of applications. But special precaution and selection should be done when very large braking torque or continous regeneration is required (for example cranes). (5) The specified conditions contain restrictions. Make sure there are not any issues * Calculated based on using a standard 4-pole motor. * The simplified selection table above cannot be used in cases where a 10% ED is exceeded 7 Specifications 7-20 7-3 Options DC Reactor (AX-RC-DE) Dimensional Drawing Figure 1 Figure 2 B C F D E A Voltage Reference AX-RC Fig Dimensions A B 06750061-DE 84 03510093-DE 113 1 108 135 01110309-DE Specifications 120 200V 152 124 136 146 00590614-DE 160 150 177 00440859-DE 00301275-DE 195 00231662-DE 240 101 161 196 198 H 66 5 7.5 2 182.6 162.5 120 135 82 6.5 94 7 160 185 115 14000047-DE 84 113 88 123 228 119 - 108 135 1 04410167-DE 120 152 03350219-DE 02330307-DE 150 177 01750430-DE 01200644-DE 133 136 146 160 182.6 10 25.5 - - 12 34.0 38.0 42.0 101 66 5 120 82 6.5 135 94 7 7.5 2 1.60 1.95 9.5 160 115 7 185 3.70 5.20 9.5 2 6.00 11.4 14.3 88 162.5 6.00 11.4 1.22 161 195 3.20 14.3 116 10100069-DE 1.60 17.0 149 105 Kg 5.20 2 109 200 9.5 9.5 96 43000020-DE 27000030-DE 17.0 10 00920797-DE 196 123 00741042-DE 188 109 34.0 00611236-DE 198 119 38.0 240 00501529-DE 200 228 12 00312446-DE 42.0 48.8 67.0 216 00213613-DE - 149 00372094-DE 00252981-DE 25.5 2 228 7-21 G 1.95 228 00133057-DE 06400116-DE F 1.22 188 2 00162500-DE 400V 105 00840437-DE 00192015-DE E 116 02510138-DE 01600223-DE D 96 10700032-DE 7 C 300 133 250 236 288 67.0 153 79.0 7-3 Options Specifications Voltage Inverter Type RX- Max. applicable motor output kW Reference Current value (A) Inductance (mH) A2004 0.4 AX-RC10700032-DE 3.2 10.70 A2007 0.7 AX-RC06750061-DE 6.1 6.75 A2015 1.5 AX-RC03510093-DE 9.3 3.51 A2022 2.2 AX-RC02510138-DE 13.8 2.51 A2037 3.7 AX-RC01600223-DE 22.3 1.60 A2055 5.5 AX-RC01110309-DE 30.9 1.11 A2075 7.5 AX-RC00840437-DE 43.7 0.84 A2110 11.0 AX-RC00590614-DE 61.4 0.59 A2150 15.0 AX-RC00440859-DE 85.9 0.44 A2185 / A2220 18.5 to 22 AX-RC00301275-DE 127.5 0.30 A2300 30 AX-RC00231662-DE 166.2 0.23 A2370 37 AX-RC00192015-DE 201.5 0.19 A2450 45 AX-RC00162500-DE 250.0 0.16 A2550 55 AX-RC00133057-DE 305.7 0.13 A4004 0.4 AX-RC43000020-DE 2.0 43.00 A4007 0.7 AX-RC27000030-DE 3.0 27.00 A4015 1.5 AX-RC14000047-DE 4.7 14.00 A4022 2.2 AX-RC10100069-DE 6.9 10.10 A4040 4.0 AX-RC06400116-DE 11.6 6.40 A4055 5.5 AX-RC04410167-DE 16.7 4.41 A4075 7.5 AX-RC03350219-DE 21.9 3.35 A4110 11.0 AX-RC02330307-DE 30.7 2.33 A4150 15.0 AX-RC01750430-DE 43.0 1.75 A4185 / A4220 18.5 to 22 AX-RC01200644-DE 64.4 1.20 A4300 30 AX-RC00920797-DE 79.7 0.92 A4370 37 AX-RC00741042-DE 104.2 0.74 A4450 45 AX-RC00611236-DE 123.6 0.61 A4550 55 AX-RC00501529-DE 152.9 0.50 B4750 75 AX-RC00372094-DE 209.4 0.37 B4900 90 AX-RC00312446-DE 244.6 0.31 B411K 110 AX-RC00252981-DE 298.1 0.25 B413K 132 AX-RC00213613-DE 361.3 0.21 200V 7 Specifications 400V 7-22 7-3 Options External EMC Filter (AX-FIR-RE) Dimensional Drawing Footprint Dimensions H Book Type Dimensions W W H drive mounts L output flexes Voltage L X Inverter model X Y Y Model Dimensions L W H X Y M 305 125 45 290 110 M5 Filter type Weight KG 3G3RX-A2004 3G3RX-A2007 7 3G3RX-A2015 AX-FIR2018-RE 3G3RX-A2022 2.0 Footprint 3G3RX-A2037 Specifications 3G3RX-A2055 3G3RX-A2075 3x200 V AX-FIR2053-RE 312 212 56 296 110 M6 2.5 3G3RX-A2110 3G3RX-A2150 3G3RX-A2185 AX-FIR2110-RE 8.0 3G3RX-A2220 3G3RX-A2300 3G3RX-A2370 3G3RX-A2450 3G3RX-A2550 AX-FIR2145-RE 455 110 240 414 80 Book type 8.6 AX-FIR3250-RE 13 AX-FIR3320-RE 13.2 3G3RX-A4004 3G3RX-A4007 3G3RX-A4015 AX-FIR3010-RE 305 125 45 290 110 M5 AX-FIR3030-RE 312 212 50 296 189 M6 AX-FIR3053-RE 451 252 60 435 229 M6 3G3RX-A4300 AX-FIR3064-RE 598 310 70 578 265 M8 3G3RX-A4370 AX-FIR3100-RE 1.9 3G3RX-A4022 3G3RX-A4040 3G3RX-A4055 3G3RX-A4075 Footprint 2.2 3G3RX-A4110 3G3RX-A4150 3x400 V 3G3RX-A4185 4.5 3G3RX-A4220 3G3RX-A4450 3G3RX-A4550 3G3RX-B4750 3G3RX-B4900 3G3RX-B411K 3G3RX-B413K 7-23 AX-FIR3130-RE 455 110 240 414 80 - 8.6 Book type AX-FIR3250-RE 386 AX-FIR3320-RE 7.0 8.0 260 135 240 235 13.0 13.2 7-3 Options Output AC Reactor (AX-RAO-DE) Dimensional Drawing Dimensions Weight Kg Reference B2 C2 D E F AX-RAO11500026-DE 120 70 120 80 52 5.5 1.78 AX-RAO07600042-DE 120 70 120 80 52 5.5 1.78 AX-RAO04100075-DE 120 80 120 80 62 5.5 2.35 AX-RAO03000105-DE 120 80 120 80 62 5.5 2.35 AX-RAO01830160-DE 180 85 190 140 55 6 5.5 AX-RAO01150220-DE 180 85 190 140 55 6 5.5 AX-RAO00950320-DE 180 85 205 140 55 6 6.5 AX-RAO00630430-DE 180 95 205 140 65 6 9.1 AX-RAO00490640-DE 180 95 205 140 65 6 9.1 AX-RAO00390800-DE 240 110 275 200 75 6 16.0 AX-RAO00330950-DE 240 110 275 200 75 6 16.0 AX-RAO00251210-DE 240 110 275 200 75 6 16.0 AX-RAO00191450-DE 240 120 275 200 85 6 18.6 AX-RAO00161820-DE 240 150 275 200 110 6 27.0 AX-RAO00132200-DE 240 - - 200 110 6 27.0 AX-RAO16300038-DE 120 70 120 80 52 5.5 1.78 AX-RAO11800053-DE 120 80 120 80 52 5.5 2.35 AX-RAO07300080-DE 120 80 120 80 62 5.5 2.35 AX-RAO04600110-DE 180 85 190 140 55 6 5.5 AX-RAO03600160-DE 180 85 205 140 55 6 6.5 AX-RAO02500220-DE 180 95 205 140 55 6 9.1 AX-RAO02000320-DE 180 105 205 140 85 6 11.7 AX-RAO01650400-DE 240 110 275 200 75 6 16.0 AX-RAO01300480-DE 240 120 275 200 85 6 18.6 AX-RAO01030580-DE 240 120 275 200 85 6 18.6 AX-RAO00800750-DE 240 120 275 200 110 6 27.0 AX-RAO00680900-DE 240 150 275 200 110 6 27.0 7 Specifications A 7-24 7-3 Options Dimensions Weight Kg Reference A B2 C2 D E F AX-RAO00531100-DE 240 150 275 200 110 6 27.0 AX-RAO00401490-DE 300 165 320 200 125 6 44.0 AX-RAO00331760-DE 300 165 320 200 125 6 44.0 AX-RAO00262170-DE 360 - - 300 145 8 70.0 AX-RAO00212600-DE 360 - - 300 145 8 70.0 Specifications Voltage 7 Specifications 200 V class 400 V clas 7-25 Max. applicable motor output kW Reference Current value (A) Inductance (mH) 0.4 AX-RAO11500026-DE 2.6 11.50 0.75 AX-RAO07600042-DE 4.2 7.60 1.5 AX-RAO04100075-DE 7.5 4.10 2.2 AX-RAO03000105-DE 10.5 3.00 3.7 AX-RAO01830160-DE 16.0 1.83 5.5 AX-RAO01150220-DE 22.0 1.15 7.5 AX-RAO00950320-DE 32.0 0.95 11 AX-RAO00630430-DE 43.0 0.63 15 AX-RAO00490640-DE 64.0 0.49 18.5 AX-RAO00390800-DE 80.0 0.39 22 AX-RAO00330950-DE 95.0 0.33 30 AX-RAO00251210-DE 121.0 0.25 37 AX-RAO00191450-DE 145.0 0.19 45 AX-RAO00161820-DE 182.0 0.16 55 AX-RAO00132200-DE 220.0 0.13 0.4 to 1.5 AX-RAO16300038-DE 3.8 16.30 2.2 AX-RAO11800053-DE 5.3 11.80 4.0 AX-RAO07300080-DE 8.0 7.30 5.5 AX-RAO04600110-DE 11.0 4.60 7.5 AX-RAO03600160-DE 16.0 3.60 11 AX-RAO02500220-DE 22.0 2.50 15.0 AX-RAO02000320-DE 32.0 2.00 18.5 AX-RAO01650400-DE 40.0 1.65 22 AX-RAO01300480-DE 48.0 1.30 30 AX-RAO01030580-DE 58.0 1.03 37 AX-RAO00800750-DE 75.0 0.80 45 AX-RAO00680900-DE 90.0 0.68 55 AX-RAO00531100-DE 110.0 0.53 75 AX-RAO00401490-DE 149.0 0.40 90 AX-RAO00331760-DE 176.0 0.33 110 AX-RAO00262170-DE 217.0 0.26 132 AX-RAO00212600-DE 260.0 0.21 7-3 Options Input AC Reactor (AX-RAI-DE) Dimensional Drawing Dimensions Voltage Reference A B1 B2 C1 C2 D E F 120 80 62 5.5 Weight Kg 7 AX-RAI02800100-DE 120 80 2.35 AX-RAI00880200-DE Specifications AX-RAI00350335-DE 200V AX-RAI00180670-DE - 55 140 180 AX-RAI00091000-DE 205 AX-RAI00071550-DE AX-RAI00042300-DE 105 240 130 AX-RAI07700050-DE AX-RAI03500100-DE 5.5 190 85 - 6 205 210 - 200 70 120 120 85 11.7 75 16.0 52 1.78 80 80 5.5 2.5 190 AX-RAI00740335-DE AX-RAI00360500-DE 2.35 62 AX-RAI01300170-DE 400V 6.5 85 5.5 55 140 180 6.5 205 AX-RAI00290780-DE 105 85 11.7 6 16.0 AX-RAI00191150-DE 110 AX-RAI00111850-DE AX-RAI00072700-DE 275 240 75 200 165 - 210 - 16.0 110 27.0 7-26 7-3 Options Specifications Voltage Max. applicable motor output kW Reference Current value A Inductance mH 0.4 to 1.5 AX-RAI02800100-DE 10.0 2.8 2.2 to 3.7 AX-RAI00880200-DE 20.0 0.88 5.5 to 7.5 AX-RAI00350335-DE 33.5 0.35 11.0 to 15.0 AX-RAI00180670-DE 67.0 0.18 18.5 to 22.0 AX-RAI00091000-DE 100.0 0.09 30.0 to 37.0 AX-RAI00071550-DE 155.0 0.07 45.0 to 55.0 AX-RAI00042300-DE 230.0 0.04 0.4 to 1.5 AX-RAI07700050-DE 5.0 7.7 2.2 to 4.0 AX-RAI03500100-DE 10.0 3.5 5.5 to 7.5 AX-RAI01300170-DE 17.0 1.3 11.0 to 15.0 AX-RAI00740335-DE 33.5 0.74 18.5 to 22.0 AX-RAI00360500-DE 50.0 0.36 30.0 to 37.0 AX-RAI00290780-DE 78.0 0.29 45.0 to 55.0 AX-RAI00191150-DE 115.0 0.19 75.0 to 90.0 AX-RAI00111850-DE 185.0 0.11 110.0 to 132.0 AX-RAI00072700-DE 270.0 0.07 3 phase 200V 3 phase 400V Specifications 7 Chokes (AX-FER-RE) Dimensional Drawing X Øm W Y L H Reference 7-27 Ød D diameter Motor KW AX-FER2102-RE 21 AX-FER2515-RE Dimensions Weight Kg L W H X Y m < 2.2 85 22 46 70 - 5 0.1 25 < 15 105 25 62 90 - 5 0.2 AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7 AX-FER6055-RE 60 < 55 200 65 170 180 45 6 1.7 7-3 Options AX-OP05-E 7 Specifications 7-28 7-3 Options Digital Operator (3G3AX-OP) 3G3AX-OP01 (7) 10 Data display RUN command LED indicator Operation keys FREQ adjuster 2-M3 d 20.5 7 18 18 16.5 8.8 15.3 Specifications 2-4 Panel cut dimensions External dimensions 7-29 Height (55 mm) × Width (70 mm) × Depth (10 mm) Appendix Appendix-1 Appendix-2 Appendix-3 Appendix-4 Parameter List................................ App-1 Product Life Curve......................... App-47 Life Alarm Output .......................... App-48 EC Declaration of Conformity....... App-49 Appendix-1 Parameter List AppAppendix Appendix-1 Parameter List Monitor Mode (d) •The default setting displays "d001" at power-on. To select the optional display, change the setting in "b038". Appendix Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page d001 Output frequency monitor [Output FQ] 0.00 to 400.00  Yes Hz 4-1 d002 Output current monitor [Output current] 0.0 to 9999.0   A 4-1 d003 Rotation direction monitor [Rotation] FWD: Forward STOP: Stop REV: Reverse    4-1 d004 PID feedback value monitor [PID-FB] 0.00 to 999000.00 (Enabled when the PID function is selected)    4-1 d005 Multi-function input monitor [Input]    4-2    4-2 MONITOR-A d005 Input d006 Example FW, Multi-function input terminals 7, 2, 1: ON Multi-function input terminals 8, 6, 5, 4, 3: OFF HLHLLLLHH FW 8 7 6 5 4 3 H001 Multi-function output monitor [Output] M1-STOP ALL 2 1 00:OFF MONITOR-A M1-STOP ALL d006 Output LLLLH H Example Multi-function output terminals 12, 11: ON Relay output terminal AL2, Multi-function output terminals 15, 14, 13: OFF AL2 15 14 13 12 11 H001 00:OFF d007 Output frequency monitor (after conversion) [Scaled FQ] 0.00 to 39960.00 (Output frequency x Conversion factor of b086)  Yes  4-2 d008 Real frequency monitor [Actual FQ] -400.00 to 400.00   Hz 4-3 d009 Torque reference monitor [Torque command] -200 to 200   % 4-3 d010 Torque bias monitor [Torque bias] -200 to 200   % 4-3 d012 Output torque monitor [Output Torque] -200 to 200   % 4-3 d013 Output voltage monitor [Output Voltage] 0.0 to 600.0   V 4-3 App-1 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page d014 Input power monitor 0.0 to 999.9 [Input Power]   W 4-4 d015 Power ON time monitor [Watt-hour] 0.0 to 999999.9    4-4 d016 Total RUN time [RUN time] 0 to 999999   h 4-4 d017 Power ON time monitor [ON time] 0 to 999999   h 4-4 d018 Fin temperature monitor [Heatsink Tmp.] -020. to 200.0   C 4-4 d019 Motor temperature monitor [Motor tmp.] -020. to 200.0   C 4-5 d022 Life assessment monitor [Life (C/F)]    4-5 MONITOR-A M1-STOP ALL 1: Main circuit board capacitor service life 2: Cooling fan rpm reduction d022 Life(C/F) LL 2 1 H001 00:OFF Program counter [Program Counter] 0 to 1024     d024 Program number [Program No.] 0 to 9999     d025 Drive programming monitor (UM0) [UM0] -2147483647 to 2147483647     d026 Drive programming monitor (UM1) [UM1] -2147483647 to 2147483647     d027 Drive programming monitor (UM2) [UM2] -2147483647 to 2147483647     d028 Pulse counter monitor [Pls. Cnt.] 0 to 2147483647    4-6 d029 Position command monitor [Set pos] -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected    4-6 d030 Current position monitor [Curnt pos] -1073741823 to 1073741823 when HAPR is selected -268435456 to 268435456 when APR2 is selected    4-6 4-137 d031 Clock [Clock] Setting Data and Time for the LCD digital operator     App-2 Appendix d023 Appendix-1 Parameter List Appendix Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page d060 Inverter mode [Inverter mode] 00 to 01     d080 Fault frequency monitor [Trip Counter] 0 to 65535   Time 4-6 d081 Fault monitor 1 (Latest) [ERR1] 4-7 d082 Fault monitor 2 [ERR2] 4-7 d083 Fault monitor 3 [ERR3] d084 Fault monitor 4 [ERR4] d085 Fault monitor 5 [ERR5] 4-7 d086 Fault monitor 6 [ERR6] 4-7 d090 Warning monitor [WARN] Warning code 0 to 385    4-7 d102 DC voltage monitor [DC Voltage] 0.0 to 999.9   V 4-7 d103 Regenerative braking load rate monitor [BRD load] 0.0 to 100.0   % 4-7 d104 Electronic thermal monitor [E.Thermal] 0.0 to 100.0   % 4-7 App-3 Error code (condition of occurrence) Output frequency [Hz]  Output current [A] Internal DC voltage [V] RUN time [h] ON time [h] 4-7    4-7 Appendix-1 Parameter List Basic Function Mode (F) Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page F001 Output frequency setting/monitor [SetFrequency (TM)] 0.0/Starting frequency to 1st/2nd/3rd max. frequency 0.00 to 400.00 0.00 Yes Hz 4-8 F002 Acceleration time 1 [Accel.time1] 0.01 to 3600.00 10.00 Yes s 4-8 F202 * 2nd acceleration time 1 [Accel.time1-M2] 0.01 to 3600.00 10.00 Yes s 4-8 F302 * 3rd acceleration time 1 [Accel.time1-M3] 0.01 to 3600.00 10.00 Yes s 4-8 F003 Deceleration time 1 0.01 to 3600.00 [Decel.time1] 10.00 Yes s 4-8 F203 * 2nd deceleration time 1 [Decel.time1-M2] 0.01 to 3600.00 10.00 Yes s 4-8 F303 * 3rd deceleration time 1 [Decel.time1-M3] 0.01 to 3600.00 10.00 Yes s 4-8 F004 Operator rotation direction selection [Run key direction] 00: FWD (Forward) 01: REV (Reverse) 00 No  4-9 App-4 Appendix * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. Appendix-1 Parameter List Extended Function Mode Analog input, Others Appendix Basic setting Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page 01 No  4-10 4-144 No  4-11 A001 Frequency reference selection [Frequency source] 00: VR (Digital Operator (FREQ adjuster)) (Enabled when 3G3AX-OP01 is used.) 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 06: Pulse train frequency 07: EzSQ (Drive programming) 10: (Math) Operation function result A002 RUN command selection [RUN cmd source] 01: Terminal 02: Digital Operator (F001) 03: RS485 (ModBus communication) 04: Option 1 05: Option 2 01 A003 Base frequency [Base Frequency] 30 to Maximum frequency [A004] 50 A203 * 2nd set base frequency 30 to 2nd maximum frequency [A204] [Base Frequency-M2] A303 * 3rd set base frequency 30 to 3rd maximum frequency [A304] [Base Frequency-M3] 50 A004 Maximum frequency [Max.Frequency] A003 to 400 50 A204 * 2nd maximum frequency [Max.Frequency-M2] A203 to 400 50 A304 * 3rd maximum frequency [Max.Frequency-M3] A303 to 400 50 O/OI selection [AT Select] 00: [O]/[O2] Switches between O/OI terminal AT 01: [O]/[O2] Switches between O/O2 terminal AT 02: [O]/VR Switches between O/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 03: [OI]/VR Switches between OI/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 04: [O2]/VR Switches between O2/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 00 A005 50 4-11 4-112 No Hz 4-11 No Hz 4-12 No  4-12 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-5 Appendix-1 Parameter List Function name Monitor or data range Default setting Changes during operation Unit Page 03 No  4-12 A006 O2 selection [O2 Select] 00: [O2] only 01: [O/OI-P] auxiliary frequency reference (not reversible) 02: [O/OI-PM] auxiliary frequency reference (reversible) 03: [OFF] O2 disabled A011 O start frequency [[O] start FQ] 0.00 to 400.00 0.00 No Hz A012 O end frequency [[O] end FQ] 0.00 to 400.00 0.00 No Hz A013 O start ratio [[O] start %] 0 to 100 0 No % A014 O end ratio [[O] end %] 0 to 100 100 No % A015 O start selection [[O] start FQ select] 00: External start frequency (A011 set value) 01: 0 Hz 01 No  A016 O, O2, OI sampling [Analog-in filter] 1 to 30 31 (with 500 ms filter ± 0.1 Hz hysteresis) 31 No  4-15 A017 Drive Programming (EzSQ) Selection [EzSQ select] 0: Disable 1: [PRG] start 2: Always ON 00 No   A019 Multi-step speed selection [Multispeed select] 00: Binary: 16-step selection with 4 terminals 01: Bit: 8-step selection with 7 terminals 00 No  4-16 A020 Multi-step speed reference 0 [Multispeed 0] 0.00 to Max. Frequency [A004] 6.00 Yes Hz A220 * 2nd multi-step speed reference 0 [Multispeed 0-M2] 0.00 to Max. Frequency [A204] 6.00 Yes Hz A320 * 3rd multi-step speed reference 0 0.00 to Max. Frequency [A304] [Multispeed 0-M3] 6.00 Yes Hz 4-14 4-8 4-16 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-6 Appendix Multi-step speed, Jogging Analog input, Others Parameter No. Appendix-1 Parameter List Multi-step speed, Jogging Appendix Parameter No. Function name Monitor or data range Default setting A021 Multi-step speed reference 1 [Multispeed 1] 0.00 A022 Multi-step speed reference 2 [Multispeed 2] 0.00 A023 Multi-step speed reference 3 [Multispeed 3] 0.00 A024 Multi-step speed reference 4 [Multispeed 4] 0.00 A025 Multi-step speed reference 5 [Multispeed 5] 0.00 A026 Multi-step speed reference 6 [Multispeed 6] 0.00 A027 Multi-step speed reference 7 [Multispeed 7] 0.00 A028 Multi-step speed reference 8 [Multispeed 8] A029 Multi-step speed reference 9 [Multispeed 9] 0.00 A030 Multi-step speed reference 10 [Multispeed 10] 0.00 A031 Multi-step speed reference 11 [Multispeed 11] 0.00 A032 Multi-step speed reference 12 [Multispeed 12] 0.00 A033 Multi-step speed reference 13 [Multispeed 13] 0.00 A034 Multi-step speed reference 14 [Multispeed 14] 0.00 A035 Multi-step speed reference 15 [Multispeed 15] 0.00 0.0/Starting frequency to Max. frequency 0.00 Changes during operation Unit Page Yes Hz 4-16 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-7 Appendix-1 Parameter List Parameter No. Multi-step speed, Jogging Monitor or data range Jogging frequency [Jog frequency] 0.00/Starting frequency to 9.99 A039 Jogging stop selection [Jog stop mode] 00: FRS (Free running on jogging stop/ Disabled in operation) 01: DEC (Deceleration stop on jogging stop/ Disabled in operation) 02: DB (DC injection braking on jogging stop/ Disabled in operation) 03: FRS (RUN) (Free running on jogging stop/Enabled in operation) 04: DEC (RUN) (Deceleration stop on jogging stop/Enabled in operation) 05: DB (RUN) (DC injection braking on jogging stop/Enabled in operation) A041 Torque boost selection [TRQ boost sel] A038 Default setting Changes during operation Unit 6.00 Yes Hz 04 No  No  Yes % Page 4-18 00 00: Manual torque boost 01: Automatic torque boost A241 * 2nd torque boost selection [TRQ boost sel-M2] A042 Manual torque boost voltage [TRQ boost V%] A242 * 2nd manual torque boost voltage [TRQ boost V%-M2] A342 * 3rd manual torque boost voltage [TRQ boost V%-M3] 1.0 A043 Manual torque boost frequency [TRQ boost FQ%] 5.0 A243 * 2nd manual torque boost frequency 0.0 to 50.0 [TRQ boost FQ%-M2] 5.0 A343 * 3rd manual torque boost frequency [TRQ boost FQ%M3]] 5.0 00 1.0 0.0 to 20.0 1.0 4-19 Yes % * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-8 Appendix V/f characteristics Function name Appendix-1 Parameter List Parameter No. V/f characteristics Monitor or data range Default setting V/f characteristics selection [V/F select] 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) A244 * 2nd V/f characteristics selection [V/F select-M2] 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 02: Free V/f (characteristics) 03: SLV (Sensorless vector control) 04: 0SLV (0-Hz sensorless vector control) 05: V2 (Sensor vector control) 00 A344 * 3rd V/f characteristics selection [V/F select-M3] 00: VC (Constant torque characteristics) 01: VP (Special reduced torque characteristics) 00 A045 Output voltage gain [V/F gain] 20 to 100 100 A046 Automatic torque boost voltage compensation gain [A.TQ-BST V gain] 0 to 255 100 A246 * 2nd automatic torque boost voltage compensation gain [A.TQ-BST V gainM2] A047 Automatic torque boost slip compensation gain [A.TQ-BST SL gain] A247 * 2nd automatic torque boost slip compensation gain [A.TQ-BST SL gainM2] A044 Appendix Function name 0 to 255 Changes during operation Unit Page No  4-21 Yes % 4-24 Yes  00 100 4-20 0 to 255 100 Yes 0 to 255  100 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-9 Appendix-1 Parameter List Function name Monitor or data range Default setting Changes during operation Unit Page 01 No  4-24 4-112 4-24 A051 DC injection braking selection [DB enable] 00: OFF (Disabled) 01: ON (Enabled) 02: ON (FQ) (Frequency control [A052 set value]) A052 DC injection braking frequency [DB Frequency] 0.00 to 400.00 0.50 No Hz A053 DC injection braking delay time [DB wait time] 0.0 to 5.0 0.0 No s DC injection braking power [DB force] 0 to 100 (0.4 to 55 kW) 50 No % A054 0 to 80 (75 to 132 kW) 40 No % A055 DC injection braking time [DB decel time] 0.0 to 60.0 0.5 No s A056 DC injection braking method selection [DB input select] 00: Edge operation 01: Level operation 01 No  A057 Startup DC injection braking power [DB force start] 0 to 100 (0.4 to 55 kW) 0 to 80 (75 to 132 kW) 0 No % A058 Startup DC injection braking time [DB time start] 0.0 to 60.0 0.0 No s DC injection braking carrier frequency [DB carrier FQ] 0.5 to 15.0 (0.4 to 55 kW) 5.0 No kHz A059 0.5 to 10.0 (75 to 132 kW) 3.0 No kHz No Hz A061 Frequency upper limit 0.00/Frequency lower limit to Max. [FQ upper limit] Frequency A261 * 2nd frequency upper limit [FQ upper limit-M2] A062 Frequency lower limit 0.00/Starting frequency to Frequency upper [FQ lower limit] limit 0.00 A262 * 2nd frequency lower 0.00/Starting frequency to 2nd frequency limit upper limit [FQ lower limit-M2] 0.00 0.00/2nd frequency lower limit to 2nd Max. Frequency 4-24 Appendix Upper/Lower limiter, Jump DC injection braking Parameter No. 0.00 0.00 4-28 No Hz * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-10 Appendix-1 Parameter List PID control Appendix Upper/Lower limit, Jump Parameter No. Function name Monitor or data range Default setting Changes during operation Unit No Hz A063 Jump frequency 1 [Jump FQ1 Center] 0.00 A064 Jump frequency width 1 [Jump FQ1 Width] 0.50 A065 Jump frequency 2 [Jump FQ2 Center] 0.00 A066 Jump frequency width 2 [Jump FQ2 Width] A067 Jump frequency 3 [Jump FQ3 Center] 0.00 A068 Jump frequency width 3 [Jump FQ3 Width] 0.50 A069 Acceleration stop frequency [Accel hold FQ] 0.00 to 400.00 0.00 No Hz A070 Acceleration stop time [Accel hold time] 0.0 to 60.0 0.0 No s A071 PID selection [PID enable] 00: OFF (Disabled) 01: ON (+) (Enabled) 02: ON (+/-) (Reverse output enabled) 00 No  A072 PID P gain [PID P gain] 0.2 to 5.0 1.0 Yes  A073 PID I gain [PID I gain] 0.0 to 3600.0 1.0 Yes s A074 PID D gain [PID D gain] 0.00 to 100.00 0.00 Yes s A075 PID scale [PID scale convert] 0.01 to 99.99 1.00 No Time A076 PID feedback selection [PV source select] 00: OI 01: O 02: Modbus (RS485 communication) 03: Pulse (Pulse train frequency) 10: Math (Operation function output) Jump frequency: 0.0 to 400.0 Jump frequency width: 0.0 to 10.0 Page 0.50 4-30 4-31 00 No  A077 00: OFF (Deviation = Target value Reverse PID function Feedback value) [Reverse PID action] 01: ON (Deviation = Feedback value - Target value) 00 No  A078 PID output limit function [PID limit] 0.0 to 100.0 0.0 No % A079 PID feedforward selection [PID F-Fwd select] 00: Disabled 01: O 02: OI 03: O2 00 No  4-31 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-11 Appendix-1 Parameter List Parameter No. Monitor or data range A081 AVR selection [AVR select] 00: Always ON 01: Always OFF 02: OFF during deceleration A082 AVR voltage selection [AVR voltage sel] 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 A085 RUN mode selection [Operation mode] 00: Normal operation 01: Energy-saving operation 02: Automatic operation A086 Energy-saving response/accuracy adjustment [Energy-saving tune] AVR RUN mode, Acceleration/Deceleration functions Function name Default setting Changes during operation Unit 02 No  Page 4-35 200/ 400 No V 00 No  4-36 0.0 to 100.0 50.0 Yes  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. Appendix App-12 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting A092 Acceleration time 2 [Accel.time2] 10.00 A292 * 2nd acceleration time 2 [Accel.time2-M2] 10.00 A392 * 3rd acceleration time 2 [Accel.time2-M3] 10.00 A093 Deceleration time 2 [Decel.time2] 10.00 A293 * 2nd deceleration time 2 [Decel.time2-M2] 10.00 A393 * 3rd deceleration time 2 [Decel.time2-M3] 10.00 A094 2-step acceleration/ deceleration selection [Acc2/Dec2 sel] RUN mode, Acceleration/Deceleration functions Appendix 0.01 to 3600.00 A294 * 2nd 2-step acceleration/ deceleration selection [Acc2/Dec2 sel-M2 A095 2-step acceleration frequency [Acc.1-2 FQ] A295 * 2nd 2-step acceleration frequency [Acc.1-2 FQ-M2] A096 2-step deceleration frequency [Dec.1-2 FQ] A296 * 2nd 2-step deceleration frequency [Dec. 1-2 FQ-M2] A097 Acceleration pattern selection [Accel.curve select] A098 Deceleration pattern selection [Decel. curve select] Changes during operation Unit Yes s Page 00 00: 2CH-Terminal (Switched via multifunction input 09) 01: Preset FQ (Switched by setting) 02: FWD-REV (Enabled only when switching forward/reverse) 4-37 No  No Hz No Hz No  00 0.00 0.00 0.00 to 400.00 0.00 0.00 00: Line 01: S-curve 02: U-curve 03: inv.U curve 04: EL-S curve 01 4-38 01 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-13 Appendix-1 Parameter List Parameter No. A101 Function name Monitor or data range OI start frequency [[OI] start FQ] Default setting Changes during operation Unit 0.00 No Hz 0.00 No Hz Page External frequency adjustment 0.00 to 400.00 A102 OI end frequency [[OI] end FQ] A103 OI start ratio [[OI] start %] 0 to OI end ratio 20 No % A104 OI end ratio [[OI] end %] OI start ratio to 100 100 No % A105 OI start selection [[OI] start FQ select] 00: Start FQ (Use OI start frequency [A101]) 01: 0 Hz 00 No  A111 O2 start frequency [[O2] start FQ] 0.00 No Hz 0.00 No Hz 4-14 Operation frequency A112 O2 end frequency [[O2] end FQ] A113 O2 start ratio [[O2] start %] -100 to O2 end ratio -100 No % A114 O2 end ratio [[O2] end %] O2 start ratio to 100 100 No % A131 Acceleration curve parameter [Accel.curve const] 02 No  A132 Deceleration curve parameter [Decel.curve const] A141 Operation frequency input A setting [A-input calc. FQ] A142 Operation frequency input B setting [B-input calc. FQ] A143 Operator selection [Calculation symbol] 00: ADD (Addition (A + B)) 01: SUB (Subtraction (A - B)) 02: MUL (Multiplication (A × B)) A145 Frequency addition amount [Add frequency] 0.00 to 99.99 100.0 to 400.0 A146 Frequency addition direction [Add direction] 00: ADD (Add A145 value to output frequency) 01: SUB (Subtract A145 value from output frequency) 01 (small curve) to 10 (large curve) 00: Operator (Digital Operator (F001)) 01: VR (Digital Operator (FREQ adjuster)) (Enabled when 3G3AX-OP01 is used.) 02: O (Input O) 03: OI (Input OI) 04: Modbus (RS485 communication) 05: Option 1 06: Option 2 07: Pulse (Pulse train frequency) 4-15 4-38 02 No  02 No  03 No  00 No  0.00 No Hz Appendix Accel/Decel Ext freq adjustment -400.00 to 400.00 4-41 4-41 00 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-14 Appendix-1 Parameter List Acceleration/Deceleration Parameter No. Momentary power interruption/Trip restart Monitor or data range Default setting Changes during operation Unit A150 EL-S-curve ratio 1 during acceleration [EL-S start accel] 0 to 50 10 No % A151 EL-S-curve ratio 2 during acceleration [EL-S end accel] 0 to 50 10 No % A152 EL-S-curve ratio 1 during deceleration [EL-S start decel] 0 to 50 10 No % A153 EL-S-curve ratio 2 during deceleration [EL-S end decel] 0 to 50 10 No % Retry selection [Restart mode UV] 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) 00 No  Page 4-39 b001 Appendix Function name 4-42 b002 Allowable momentary power interruption 0.3 to 25.0 time [Allowable UV time] 1.0 No s b003 Retry wait time [Retry wait time UV] 0.3 to 100.0 1.0 No s b004 Momentary power interruption/ undervoltage trip during stop selection [UV trip on stop] 00: OFF (Disabled) 01: ON (Enabled) 02: Decel-OFF (Disabled during stop and deceleration stop) 00 No  b005 Momentary power interruption retry time 00: 16 times selection 01: No limit [No. Of restart UV] 00 No  b006 Input phase loss protection selection [Phase loss detection] 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-46 b007 Frequency matching lower limit frequency setting [Restart min. FQ] 0.00 to 400.00 0.00 No Hz 4-42 4-71 4-87 Trip retry selection [Restart mode OV/ OC] 00: TRIP (Alarm) 01: 0 Hz start 02: f-match (Frequency matching start) 03: f-match Trip (Trip after frequency matching deceleration stop) 04: Actv. f-match (Active Frequency Matching restart) 00 No  4-42 b008 4-87 4-42 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-15 Appendix-1 Parameter List Function name Monitor or data range b009 Undervoltage retry time selection [Under voltage retry] b010 Overvoltage/ overcurrent retry time selection 1 to 3 [No. Of restart OV/ OC] b011 Trip retry wait time [Retry wait time OV/ OC] b012 Electronic thermal level [E. Thermal Level] b212 * 2nd electronic thermal level [E. Thermal LevelM2] b312 * 3rd electronic thermal level [E. Thermal LevelM3] b013 Electronic thermal characteristics selection [E. Thermal Character] b213 * 2nd electronic thermal characteristics selection [E. Thermal Character-M2] b313 * 3rd electronic thermal characteristics selection [E. Thermal Character-M3] 00: 16 times 01: No limit 0.3 to 100.0 0.20 × Rated current to 1.00 × Rated current Default setting Changes during operation Unit 00 No  3 No Time Page 4-42 1.0 No s Rated current No A 4-46 00: Reduced TRQ (Reduced torque characteristics) 01: Const TRQ (Constant torque characteristics) 02: Free set (Free setting) 00 No  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-16 Appendix Electronic Thermal Momentary power interruption/Trip restart Parameter No. Appendix-1 Parameter List Appendix Electronic Thermal Parameter No. Function name b015 Free setting, electronic thermal frequency 1 [Free E.Thermal FQ1] b017 Free setting, electronic thermal frequency 2 [Free E.Thermal FQ2] b019 Free setting, electronic thermal frequency 3 [Free E.Thermal FQ3] b016 Free setting, electronic thermal current 1 [Free E.Thermal I-1] b018 Free setting, electronic thermal current 2 [Free E.Thermal I-2] b020 Free setting, electronic thermal current 3 [Free E.Thermal I-3] Monitor or data range 0 to 400 Default setting Changes during operation Unit 0 No Hz Page 4-46 0.0 to Rated current 0.0 No A * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-17 Appendix-1 Parameter List Function name Monitor or data range Default setting Changes during operation Unit 01 No  b021 Overload limit selection [OL restrict mode] 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/ constant speed operation) 02: ON-Cnst (Enabled in constant speed operation) 03: ON-A/C(R) (Enabled in acceleration/ constant speed operation (Accelerates during regeneration)) b022 Overload limit level [OL restrict level] 0.20 × Rated current to 2.00 × Rated current 1.50 (0.4 to 55 kW) × 0.20 × Rated current to 1.80 × Rated current Rated (75 to 132 kW) current No A b023 Overload limit parameter [Decel.rate OL restrict] 0.10 to 30.00 No s b024 Overload limit selection 2 [OL restrict 2 mode] 00: OFF (Disabled) 01: ON-Acc/Cnst (Enabled in acceleration/ constant speed operation) 02: ON-Cnst (Enabled in constant speed operation) 03: ON-A/C(R) (Enabled in acceleration/ constant speed operation (Accelerates during regeneration)) 1.00 Page 4-49 No  b025 0.20 × Rated current to 2.00 × Rated current 1.50 Overload limit level 2 (0.4 to 55 kW) × [OL restrict 2 level] 0.20 × Rated current to 1.80 × Rated current Rated (75 to 132 kW) current No A b026 Overload limit parameter 2 [Decel.rate OL2 rstr] 1.00 No s b027 Overcurrent 00: OFF (Disabled) suppression function 01: ON (Enabled) [OC suppress select] 00 No  b028 Active Frequency Matching restart level [Curnt Active Fmatch] 0.20 × Rated current to 2.00 × Rated current Rated (0.4 to 55 kW) 0.20 × Rated current to 1.80 × Rated current current (75 to 132 kW) No A b029 Active Frequency Matching restart parameter [Decel.rate act.Fmatch] 0.10 to 30.00 0.50 No s b030 Starting frequency at Active Frequency Matching restart [Start FQ act.Fmatch] 00: Off FQ (Frequency at interruption) 01: Max.FQ (Max. Frequency) 02: Set FQ (Set Frequency) 00 No  0.10 to 30.00 01 4-51 4-43 4-71 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-18 Appendix Overload limit, Overcurrent Protection Parameter No. Appendix-1 Parameter List Monitor or data range Default setting Changes during operation Unit Page 01 No  4-51 b031 Soft lock selection [Softlock select] b034 RUN time/Power ON time setting [RNT/ONT time] 0 to 65535 0 No h 4-52 b035 Rotation direction limit selection [Rotation restriction] 00: FREE (Forward and Reverse are enabled) 01: FWD (Only Forward is enabled) 02: REV (Only Reverse is enabled) 00 No  4-52 b036 Reduced voltage startup selection [Reduced V start] 0 (Reduced voltage startup time: small) to 255 (Reduced voltage startup time: large) 6 No  4-53 b037 Display selection [Display restriction] 00: All (Complete display) 01: Utilized (Individual display of functions) 02: User (User setting) 03: Compare (Data comparison display) 04: Basic (Basic display) 00 No  4-53 b038 Initial screen selection [Initial display] 000 to 202 001 No  4-56 b039 User parameter automatic setting 00: OFF (Disabled) function selection 01: ON (Enabled) [Auto U param. regist] 00 No  4-57 b040 00: 4-quadrant (Four-quadrant separate setting) Torque limit selection 01: TRQ input (Terminal switch) [TRQ limit select] 02: [O] input (Analog input) 03: Option 1 04: Option 2 00 No - 4-57 4-59 b041 Torque limit 1 (Four-quadrant mode 0 to 200 (0.4 to 55 kW) forward power 0 to 180 (75 to 132 kW) running) no (Torque limit disabled) [TRQ limit FW/POW] 150 No % 4-57 4-59 Torque limit Appendix Function name 00: Lock (SFT) (Data other than b031 cannot be changed when terminal SFT is ON) 01: Only FQ (SFT) (Data other than b031 and the specified frequency parameter cannot be changed when terminal SFT is ON) 02: Lock (Data other than b031 cannot be changed) 03: Only FQ (Data other than b031 and the specified frequency parameter cannot be changed) 10: RUN chg mode (Data other than parameters changeable during operation cannot be changed) Others Lock Parameter No. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-19 Appendix-1 Parameter List Default setting Changes during operation Unit b042 Torque limit 2 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) reverse regeneration) no (Torque limit disabled) [TRQ limit RV/REG] 150 No % b043 Torque limit 3 (Four-quadrant mode 0 to 200 (0.4 to 55 kW) reverse power 0 to 180 (75 to 132 kW) running) no (Torque limit disabled) [TRQ limit RV/POW] 150 No % b044 Torque limit 4 0 to 200 (0.4 to 55 kW) (Four-quadrant mode 0 to 180 (75 to 132 kW) forward regeneration) no (Torque limit disabled) [TRQ limit FW/REG] 150 No % b045 Torque LADSTOP 00: OFF (Disabled) selection 01: ON (Enabled) [TRQ limit LADSTOP] 00 No  4-59 b046 Reverse rotation prevention selection [Rev RUN protect] 00: OFF (Disabled) 01: ON (Enabled) 00 No  4-59 b049 Dual rate selection [Dual rate select] 00: CT (Constant torque) 01: VT (Variable torque) 00 No   Others Torque limit Parameter No. Function name Monitor or data range Page 4-57 4-59 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. Appendix App-20 Appendix-1 Parameter List Appendix Others Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 00 No  b050 Selection of non-stop function at momentary power interruption [Ctrld decel. select] 00: OFF (Disabled) 01: V-Cnst (STOP) (Enabled (deceleration stop)) 02: NS1 (Enabled (without recovery)) 03: NS2 (Enabled (with recovery)) b051 Starting voltage of non-stop function at momentary power interruption [DC Volt ctrld. decel] 0.0 to 1000.0 220/ 440 No V b052 Stop deceleration level of non-stop function at momentary power interruption [OV lvl ctrld. decel] 0.0 to 1000.0 360/ 720 No V b053 Deceleration time of non-stop function at momentary power 0.01 to 3600.00 interruption [Decel time ctrld. dec] 1.00 No s b054 Deceleration starting width of non-stop function at 0.00 to 10.00 momentary power interruption [FQ drop ctrld. decel] 0.00 No Hz b055 Proportional gain setting of non-stop function at momentary power interruption [P gain ctrld. decel] 0.00 to 2.55 0.20 Yes  b056 Integral time setting of non-stop function at momentary power interruption [I gain ctrld. decel] 0.000 to 65.535 0.100 Yes s Page 4-60 4-63 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-21 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Changes during operation Unit 100 Yes % b061 Set a lower limit level. Window comparator Setting range: 0 to 100 O lower limit level Upper limit: Upper limit level - Hysteresis [Windw comp [O] min] width × 2 0 Yes % b062 Set a hysteresis width for the upper and lower Window comparator limit levels. O hysteresis width Setting range: 0 to 10 [Windw comp [O] hys] Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b063 Window comparator OI upper limit level [Windw comp [OI] max] Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 100 Yes % b064 Window comparator OI lower limit level [Windw comp [OI] min] Set a lower limit level. Setting range: 0 to 100 Upper limit: Upper limit level - Hysteresis width × 2 0 Yes % b065 Window comparator OI hysteresis width [Windw comp [OI] hys] Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b066 Window comparator O2 upper limit level [Windw comp [O2] max] Set an upper limit level. Setting range: -100 to 100 Lower limit: Lower limit level + Hysteresis width × 2 100 Yes % b067 Window comparator O2 lower limit level [Windw comp [O2] min] Set a lower limit level. Setting range: -100 to 100 Upper limit: Upper limit level - Hysteresis width × 2 -100 Yes % b068 Window comparator O2 hysteresis width [Windw comp [O2] hys] Set a hysteresis width for the upper and lower limit levels. Setting range: 0 to 10 Upper limit: (Upper limit level - Lower limit level) × 2 0 Yes % b070 Analog operation level at O disconnection [Discon Level [O]] 0 to 100/no (ignored) no No  b071 Analog operation level at OI disconnection [Discon Level [OI]] 0 to 100/no (ignored) no No  b072 Analog operation level at O2 disconnection [Discon Level [O2]] -100 to 100/no (ignored) no No  Page 4-66 Appendix b060 Window comparator O upper limit level [Windw comp [O] max] Others Set an upper limit level. Setting range: 0 to 100 Lower limit: Lower limit level + Hysteresis width × 2 Default setting 4-66 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-22 Appendix-1 Parameter List Parameter No. Monitor or data range Default setting Changes during operation Unit Cleared with the Enter key after changing to 01 00 Yes  Function name b078 Integrated power clear [Clear kWh data] b079 Integrated power display gain [kWh display gain] 1 to 1000 b082 Starting frequency [Start Frequency] b083 Carrier frequency [Carrier frequency] Page 4-4 1 No  0.10 to 9.99 0.50 No Hz 0.5 to 15.0 (0.4 to 55 kW) *Derating enabled 5.0 No kHz 0.5 to 10.0 (75 to 132 kW) *Derating enabled 3.0 No kHz 00: no (Clears the trip monitor) 01: Trip data (Initializes data) 02: Parameters )Clears the trip monitor and Initialization selection initializes data) [Initialize Mode] 03: Trip+Param (Clears the trip monitor and parameters) 04: Trp+Prm+EzSQ (Clears trip monitor, parameters and Drive program) 00 No  b085 Initialization parameter selection [Initial data select] 01 No  b086 Frequency conversion coefficient 0.1 to 99.9 [FQ scale factor] 1.0 Yes  4-2 b087 STOP key selection [STOP key enable] 00: ON (Enabled) 01: OFF (Disabled) 02: Only RESET (Disabled only during stop) 00 No  4-70 b088 Free-run stop selection [Restart after FRS] 00: 0 Hz start 01: f-match (Frequency matching start) 02: Actv. f-match (Active Frequency Matching restart) 00 No  4-71 b089 Automatic carrier 00: OFF (Disabled) reduction 01: ON (Enabled) [Auto.Carrier reduce] 00 No  4-73 b090 Usage rate of regenerative braking function [BRD use ratio] 0.0 to 100.0 0.0 No % 4-74 b091 Stop selection [Stop mode select] 00: Decel-Stop (Deceleration  Stop) 01: Free-RUN (Free-run stop) 00 No  4-70 b092 Cooling fan control [Cooling fan crtl] 00: Alws-ON (Always ON) 01: ON in RUN (ON during RUN) 01 No  b095 Regenerative braking 00: OFF (Disabled) function operation 01: RUN-ON (Enabled (Disabled during selection stop)) [BRD ctrl select] 02: Alws-ON (Enabled (Enabled during stop)) 00 No  b096 Regenerative braking 330 to 380 function ON level 660 to 760 [BRD activation] 360/ 720 No V Others Appendix b084 01 *Do not change. 4-68 4-68 4-120 4-70 4-74 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-23 Appendix-1 Parameter List Vf free setting Others Parameter No. Function name Monitor or data range 00: Disabled 01: PTC enabled 02: NTC enabled b098 Thermistor selection [Thermistor select] b099 Thermistor error level 0 to 9999 [Thermistor level] b100 Free V/f frequency 1 [Free V/F-F1] 0 to Free V/f frequency 2 b101 Free V/f voltage 1 [Free V/F-V1] 0.0 to 800.0 b102 Free V/f frequency 2 [Free V/F-F2] 0 to Free V/f frequency 3 b103 Free V/f voltage 2 [Free V/F-V2] 0.0 to 800.0 b104 Free V/f frequency 3 [Free V/F-F3] 0 to Free V/f frequency 4 b105 Free V/f voltage 3 [Free V/F-V3] 0.0 to 800.0 b106 Free V/f frequency 4 [Free V/F-F4] 0 to Free V/f frequency 5 b107 Free V/f voltage 4 [Free V/F-V4] 0.0 to 800.0 b108 Free V/f frequency 5 [Free V/F-F5] 0 to Free V/f frequency 6 b109 Free V/f voltage 5 [Free V/F-V5] 0.0 to 800.0 b110 Free V/f frequency 6 [Free V/F-F6] 0. to Free V/f frequency 7 b111 Free V/f voltage 6 [Free V/F-V6] 0.0 to 800.0 b112 Free V/f frequency 7 [Free V/F-F7] 0. to 400 b113 Free V/f voltage 7 [Free V/F-V7] 0.0 to 800.0 Default setting Changes during operation Unit 00 No  Page 4-75 3000 No  0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 0 No Hz 0.0 No V 4-22 Appendix * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-24 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 00 No  Page b120 Brake control selection [Brake control sel] 00: OFF (Disabled) 01: ON (Enabled) b121 Brake wait time for release [Brake w.time Rels] 0.00 to 5.00 0.00 No s b122 Brake wait time for acceleration [Brake w.time Accel] 0.00 to 5.00 0.00 No s b123 Brake wait time for stopping [Brake w.time Stop] 0.00 to 5.00 0.00 No s b124 Brake wait time for confirmation [Brake w.time Confirm] 0.00 to 5.00 0.00 No s b125 Brake release frequency [Brake Release FQ] 0.00 to -400.00 0.00 No Hz b126 Brake release current 0.0 to 2.00 × Rated current (0.4 to 55 kW) [Brake Release I] 0.0 to 1.80 × Rated current (75 to 132 kW) Rated current No  b127 Brake input frequency [Braking Frequency] 0.00 to 400.00 0.00 No Hz b130 Overvoltage protection function selection during deceleration [Over-V supp.select] 00: OFF (Disabled) 01: V-const (DC voltage kept constant) 02: Accel (Acceleration enabled) 01 No  b131 Overvoltage protection level during deceleration [Over-V supp. level] 200-V class: 330 to 390 400-V class: 660 to 780 380/ 760 No V b132 Overvoltage protection parameter [Over-V supp. constant] 0.10 to 30.00 1.00 No s b133 Overvoltage protection proportional gain 0.00 to 2.55 setting [Over-V supp.P-gain] 0.50 Yes  b134 Overvoltage protection integral time setting [Over-V supp.I-gain] 0.000 to 65.535 0.060 Yes s b164 Auto return initial display [Auto return init.disp] 00: OFF 01: ON 00 No   b166 Data Read/Write selection [Data R/W select] 00: R/W OK (Read/Write Ok) 01: R/W Protected (Read/Write Protected) 00 No   Others Appendix 4-77 4-78 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-25 Appendix-1 Parameter List b180 Function name Initialize trigger [Initialize trigger] C001 Multi-function input 1 selection *1 [Input [1] Function] C002 Multi-function input 2 selection [Input [2] Function] C003 Multi-function input 3 selection *1 [Input [3] Function] C004 Multi-function input 4 selection [Input [4] Function] C005 Multi-function input 5 selection [Input [5] Function] C006 Multi-function input 6 selection [Input [6] Function] C007 Multi-function input 7 selection [Input [7] Function] C008 Multi-function input 8 selection [Input [8] Function] Monitor or data range 00: No action 01: Initialize 01: RV (reverse) 02: CF1 (multi-step speed setting binary 1) 03: CF2 (multi-step speed setting binary 2) 04: CF3 (multi-step speed setting binary 3) 05: CF4 (multi-step speed setting binary 4) 06: JG (jogging) 07: DB (external DC injection braking) 08: SET (2nd control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (free-run stop) 12: EXT (external trip) 13: USP (USP function) 14: CS (commercial switch) 15: SFT (soft lock) 16: AT (analog input switching) 17: SET3 (3rd control) 18: RS (reset) 20: STA (3-wire start) 21: STP (3-wire stop) 22: F/R (3-wire forward/reverse) 23: PID (PID enabled/disabled) 24: PIDC (PID integral reset) 26: CAS (control gain switching) 27: UP (UP/DWN function accelerated) 28: DWN (UP/DWN function decelerated) 29: UDC (UP/DWN function data clear) 31: OPE (forced operator) 32: SF1 (multi-step speed setting bit 1) 33: SF2 (multi-step speed setting bit 2) 34: SF3 (multi-step speed setting bit 3) 35: SF4 (multi-step speed setting bit 4) 36: SF5 (multi-step speed setting bit 5) 37: SF6 (multi-step speed setting bit 6) 38: SF7 (multi-step speed setting bit 7) 39: OLR (overload limit switching) 40: TL (torque limit enabled) 41: TRQ1 (torque limit switching 1) 42: TRQ2 (torque limit switching 2) 43: PPI (P/PI switching) 44: BOK (Brake confirmation) 45: ORT (orientation) 46: LAC (LAD cancel) 47: PCLR (position deviation clear) 48: STAT (pulse train position command input permission) 50: ADD (frequency addition) 51: F-TM (forced terminal block) 52: ATR (torque command input permission) 53: KHC (integrated power clear) 54: SON (servo ON) 55: FOC (preliminary excitation) 56: MI1 (Drive programming input 1) 57: MI2 (Drive programming input 2) 58: MI3 (Drive programming input 3) 59: MI4 (Drive programming input 4) 60: MI5 (Drive programming input 5) 61: MI6 (Drive programming input 6) 62: MI7 (Drive programming input 7) 63: MI8 (Drive programming input 8) 65: AHD (analog command held) 66: CP1 (position command selection 1) 67: CP2 (position command selection 2) 68: CP3 (position command selection 3) 69: ORL (zero return limit signal) 70: ORG (zero return startup signal) 71: FOT (forward driving stop) 72: ROT (reverse driving stop) 73: SPD (speed/position switching) 74: PCNT (pulse counter) 75: PCC (pulse counter clear) 82: PRG (Drive program start) no: NO (no allocation) Default setting Changes during operation Unit Page 00 No   No  4-79 01 *1 12 18 02 Appendix Multi-function input terminals Others Parameter No. 03 06 08 no *1. C001 and C003 are forcibly rewritten into 18 (RS) and 64 (EMR), respectively, when the emergency shutoff function is enabled (SW1 = ON). (64 cannot be set optionally.) When SW1 is turned ON once and then OFF, C003 has no allocations ("no"). * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-26 Appendix-1 Parameter List Appendix Multi-function input terminals Parameter No. Function name Monitor or data range Default setting C011 Multi-function input 1 operation selection [Input [1] actv. State] 00 C012 Multi-function input 2 operation selection [Input [2] actv. State] 00 C013 Multi-function input 3 operation selection [Input [3] actv. State] 00 C014 Multi-function input 4 operation selection [Input [4] actv. State] 00 C015 Multi-function input 5 operation selection [Input [5] actv. State] C016 Multi-function input 6 operation selection [Input [6] actv. State] 00 C017 Multi-function input 7 operation selection [Input [7] actv. State] 00 C018 Multi-function input 8 operation selection [Input [8] actv. State] 00 C019 FW terminal operation selection [Input [FW] actv. State] 00 00: NO 01: NC 00 Changes during operation Unit Page No  4-81 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-27 Appendix-1 Parameter List Parameter No. C021 C023 C024 C025 C026 Monitor or data range 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) Multi-function output 03: OL (overload warning) terminal 11 selection 04: OD (excessive PID deviation) [Output [11] function] 05: AL (alarm output) 06: FA3 (set-frequency-only arrival signal) 07: OTQ (overtorque) 08: IP (signal during momentary power interruption) 09: UV (signal during undervoltage) 10: TRQ (torque limit) 11: RNT (RUN time over) Multi-function output 12: ONT (Power ON time over) terminal 12 selection 13: THM (thermal warning) [Output [12] function] 19: BRK (brake release) 20: BER (brake error) 21: ZS (0 Hz signal) 22: DSE (excessive speed deviation) 23: POK (position ready) 24: FA4 (set frequency exceeded 2) 25: FA5 (set frequency only 2) Multi-function output 26: OL2 (overload warning 2) terminal 13 selection 27: ODc (analog O disconnection detection) 28: OIDc (analog OI disconnection detection) [Output [13] function] 29: O2Dc (analog O2 disconnection detection) 31: FBV (PID FB status output) 32: NDc (network error) 33: LOG1 (logic operation output 1) 34: LOG2 (logic operation output 2) 35: LOG3 (logic operation output 3) Multi-function output 36: LOG4 (logic operation output 4) 37: LOG5 (logic operation output 5) terminal 14 selection 38: LOG6 (logic operation output 6) [Output [14] function] 39: WAC (capacitor life warning signal) 40: WAF (cooling fan life warning signal) 41: FR (starting contact signal) 42: OHF (fin overheat warning) 43: LOC (light load detection signal) 44: MO1 (Drive programming output 1) 45: MO2 (Drive programming output 2) Multi-function output 46: MO3 (Drive programming output 3) terminal 15 selection 47: MO4 (Drive programming output 4) [Output [15] function] 48: MO5 (Drive programming output 5) 49: MO6 (Drive programming output 6) 50: IRDY (operation ready signal) 51: FWR (forward run signal) 52: RVR (reverse run signal) 53: MJA (fatal fault signal) 54: WCO (window comparator O) 55: WCOI (window comparator OI) Relay output (AL2, 56: WCO2 (window comparator O2) 63: OPO (Option board output) AL1) function no: Not used selection (When C062 is used to select the alarm code [Alarm relay function] output, the multi-function output terminals 11 to 13, or 11 to 14 are forcibly changed to AC0 to AC2 or AC0 to AC3 [Acn 'Alarm code output'], respectively.) Default setting Changes during operation Unit Page No  4-95 00 21 03 07 Appendix Multi-function output terminal C022 Function name 01 05 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-28 Appendix-1 Parameter List Parameter No. Analog monitor Appendix C027 C028 Monitor or data range Default setting Changes during operation Unit Page FM selection [[FM] Function] When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 03: Pulse FQ (Digital output frequency) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 12: YA0 (Drive programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2) 00 No  4-109 4-118 AM selection [[AM] Function] When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 08: Pulse I (Digital current monitor) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 11: Out TRQ sign (Output torque ) 13: YA1 (Drive programming) 19: OP1 (Option board 1) 20: OP2 (Option board 2) 00 No  00 Function name 4-110 4-118 C029 AMI selection [[AMI] Function] When inverter is in sensor vector control (A044=05) the real motor speed from the motor encoder (d008 monitor) is used instead of the output frequency. 00: Output FQ (Output frequency) 01: Output I (Output current) 02: Output TRQ (Output torque) 04: Output V (Output voltage) 05: Power 06: Thermal (Thermal load rate) 07: LAD-FQ (LAD frequency) 09: Motor tmp (Motor temperature) 10: Heatsink tmp (Fin temperature) 14: YA2 (Drive programming) C030 Digital current monitor reference value [Digital I Ref.] 0.20 × Rated current to 2.00 × Rated current Rated (Current value at the digital current monitor current output 1440 Hz) No  Yes A 4-109 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-29 Appendix-1 Parameter List Function name Monitor or data range Default setting C031 Multi-function output terminal 11 contact selection [Output [11] actv. state] C032 Multi-function output terminal 12 contact selection [Output [12] actv. state] C033 Multi-function output terminal 13 contact selection [Output [13] actv. state] C034 Multi-function output terminal 14 contact selection [Output [14] actv. state] C035 Multi-function output terminal 15 contact selection [Output [15] actv. state] C036 Relay output (AL2, AL1) contact selection [Alarm RLY active state] 00: NO contact at AL2; NC contact at AL1 01: NC contact at AL2; NO contact at AL1 01 C038 Light load signal output mode [LOC out mode select] 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) 01 C039 Light load detection level [LOC out level] 0.0 to 2.00 × Rated current (0.4 to 55 kW) 0.0 to 1.80 × Rated current (75 to 132 kW) C040 Overload warning signal output mode [Overload warn mode] 00: ACC/DEC/CST (Enabled during acceleration/deceleration/constant speed) 01: Const (Enabled only during constant speed) C041 0.0: Does not operate. Overload warning 0.1 × Rated current to 2.00 × Rated current level (0.4 to 55 kW) [Overload warn level] 0.1 × Rated current to 1.80 × Rated current (75 to 132 kW) 00: NO 01: NC Changes during operation Unit Page No  4-96 No  00 Appendix Level and output terminal status Multi-function output terminal Parameter No. 4-106 Rated current No A 01 No  4-49 Rated current No A * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-30 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 0.00 No Hz C042 Arrival frequency during acceleration [FQ arrive accel.1] C043 Arrival frequency during deceleration [FQ arrive decel.1] 0.00 to 400.00 0.00 No Hz C044 PID deviation excessive level [PID deviation] 0.0 to 100.0 3.0 No % C045 Arrival frequency during acceleration 2 0.00 to 400.00 [FQ arrive accel.2] 0.00 No Hz C046 Arrival frequency during deceleration 2 0.00 to 400.00 [FQ arrive decel.2] 0.00 No Hz C052 PID FB upper limit [PID FBV high limit] 0.0 to 100.0 100.0 No % C053 PID FB lower limit [PID FBV low limit] 0.0 to 100.0 0.0 No % C055 Overtorque level (Forward power running) [OV-TRQ FW/POW] 200 No % C056 Overtorque level (Reverse regeneration) [OV-TRQ RV/REG] 200 No % C057 Overtorque level (Reverse power running) [OV-TRQ RVPOW] C058 Overtorque level (Forward regeneration) [OV-TRQ FW/REG] C061 Thermal warning level [E-Thermal warning] C062 00: OFF (Disabled) Alarm code selection 01: 3-bit [Alarm code output] 02: 4-bit C063 0 Hz detection level [0Hz detection level] C064 Fin overheat warning level 0 to 200 [Heatsink warning] 0.00 to 400.00 Page 4-98 4-31 4-98 Level and output terminal status Appendix 4-31 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 0 to 100 0.00 to 100.00 4-100 200 No % 200 No % 80 No % 4-46 00 No  4-101 0.00 No Hz 4-101 120 No C 4-105 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-31 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit C071 Communication speed selection (Baud rate selection) [Comm. baud rate] 02: Loop-back test 03: 2400 bps 04: 4800 bps 05: 9600 bps 06: 19200 bps 05 No  C072 Communication station No. selection [Modbus address] 1 to 247 1 No  C073 Communication bit length selection [Comm. Data length] 7: 7-bit 8: 8-bit 8 No  C074 Communication parity selection [Parity] 00: No parity 01: Even 02: Odd 00 No  C075 Communication stop bit selection [Stop bit] 1: 1-bit 2: 2-bit 1 No  C076 00: Trip Communication error 01: Decel-Trip (Trip after deceleration stop) selection 02: Ignore [Comm.error mode] 03: Free-RUN (Free-run stop) 04: Decel-Stop (Deceleration stop) 02 No  C077 Communication error timeout 0.00 to 99.99 [Comm. Timeout] 0.00 No s C078 Communication wait time [Comm.wait time] 0 No ms C079 Communication method selection [Comm.mode] 00: ASCII 01: ModBus-RTU C081 O adjustment [[O] span calibration] Page Communication function 4-146 Adjustment 4-146 01 No  0 to 65535 Factory default Yes   C082 OI adjustment 0 to 65535 [[OI] span calibration] Factory default Yes   C083 O2 adjustment [[O2] span calibration] 0 to 65535 Factory default Yes   C085 Thermistor adjustment [PTC span calibration] 0.0 to 1000.0 Factory default Yes  4-75 C091 Debug mode selection [Debug mode select] Use "00". * Do not change. 00 No   * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-32 Appendix 0 to 1000 4-104 4-146 Appendix-1 Parameter List Changes during operation Unit Page 00: Not save (Do not store the frequency data) 01: Save (Store the frequency data) 00 No  4-90 Reset selection [Reset mode select] 00: ON-RESET (Trip reset at power-on) 01: OFF-RESET (Trip reset when the power is OFF) 02: On in Trip (Enabled only during trip (Reset when the power is ON)) 03: Trip RESET (Trip reset only) 00 Yes  4-87 4-137 C103 Reset frequency matching selection [Restart after reset] 00: 0 Hz start 01: f-match (Frequency matching start) 02: Actv.f-match (Active Frequency Matching restart) 00 No  4-87 C105 FM gain setting [FM gain adjust] 50 to 200 100 Yes % 4-110 C106 AM gain setting [AM gain adjust] 50 to 200 100 Yes % C107 AMI gain setting [AMI gain adjust] 50 to 200 100 Yes % C109 AM bias setting [AM bias adjust] 0 to 100 0 Yes % C110 AMI bias setting [AMI bias adjust] 0 to 100 20 Yes % C111 Overload warning level 2 [Overload warn lvl 2] 0.0 to 2.00 × Rated current (0.4 to 55 kW) 0.0 to 1.80 × Rated current (75 to 132 kW) Rated current No A C121 O zero adjustment [[O] 0 calibration] 0 to 65535 Factory default Yes  C122 OI zero adjustment [[OI] 0 calibration] 0 to 65535 Factory default Yes  C123 O2 zero adjustment [[O2] 0 calibration] 0 to 65535 Factory default Yes  C101 UP/DWN selection [UP/DWN memory mode] C102 Terminal Meter adjustment Others Function name Adjustment Appendix Default setting Parameter No. Monitor or data range 4-111 4-49  * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-33 Appendix-1 Parameter List Function name Monitor or data range Default setting C130 Output 11 ON delay [Output [11] ON delay] 0.0 to 100.0 0.0 C131 Output 11 OFF delay [Output [11] OFF 0.0 to 100.0 delay] 0.0 C132 Output 12 ON delay [Output [12] ON delay] 0.0 to 100.0 0.0 C133 Output 12 OFF delay [Output [12] OFF 0.0 to 100.0 delay] 0.0 C134 Output 13 ON delay [Output [13] ON delay] 0.0 to 100.0 0.0 C135 Output 13 OFF delay [Output [13] OFF 0.0 to 100.0 delay] 0.0 C136 Output 14 ON delay [Output [14] ON delay] 0.0 to 100.0 0.0 C137 Output 14 OFF delay [Output [14] OFF 0.0 to 100.0 delay] 0.0 C138 Output 15 ON delay [Output [15] ON delay] 0.0 to 100.0 0.0 C139 Output 15 OFF delay [Output [15] OFF 0.0 to 100.0 delay] 0.0 C140 Relay output ON delay 0.0 to 100.0 [Alarm-RLY ON delay] 0.0 C141 Relay output OFF delay [Alarm-RLY OFF delay] 0.0 to 100.0 0.0 C142 Logic output signal 1 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 1 operand A] 00 C143 Logic output signal 1 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 2 operand B] 00 Changes during operation Unit Page No s 4-108 Appendix Output terminal operation function Parameter No. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-34 Appendix-1 Parameter List Output terminal operation function Appendix Parameter No. Function name Monitor or data range 00: AND 01: OR 02: XOR Default setting C144 Logic output signal 1 operator selection [Log.out 1 operator] C145 Logic output signal 2 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 2 operand A] 00 C146 Logic output signal 2 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 2 operand B] 00 C147 Logic output signal 2 operator selection [Log.out 2 operator] 00 C148 Logic output signal 3 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 3 operand A] 00 C149 Logic output signal 3 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 3 operand B] 00 C150 Logic output signal 3 operator selection [Log.out 3 operator] 00 C151 Logic output signal 4 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 4 operand A] 00 C152 Logic output signal 4 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 4 operand B] 00 C153 Logic output signal 4 operator selection [Log.out 4 operator] 00 C154 Logic output signal 5 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 5 operand A] 00 C155 Logic output signal 5 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 5 operand B] 00 C156 Logic output signal 5 operator selection [Log.out 5 operator] C157 Logic output signal 6 Same as options for C021 to C026 selection 1 (excluding LOG1 to LOG6) [Log.out 6 operand A] 00 C158 Logic output signal 6 Same as options for C021 to C026 selection 2 (excluding LOG1 to LOG6) [Log.out 6 operand B] 00 C159 Logic output signal 6 operator selection [Log.out 6 operator] 00 00: AND 01: OR 02: XOR 00: AND 01: OR 02: XOR 00: AND 01: OR 02: XOR 00: AND 01: OR 02: XOR 00: AND 01: OR 02: XOR Changes during operation Unit Page No  4-102 No  4-102 00 00 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-35 Appendix-1 Parameter List Function name Monitor or data range Default setting C160 Input terminal response time 1 [Input [1] resp.time] 0 to 200 (× 2 ms) 1 C161 Input terminal response time 2 [Input [2] resp.time] 0 to 200 (× 2 ms) 1 C162 Input terminal response time 3 [Input [3] resp.time] 0 to 200 (× 2 ms) 1 C163 Input terminal response time 4 [Input [4] resp.time] 0 to 200 (× 2 ms) 1 C164 Input terminal response time 5 [Input [5] resp.time] 0 to 200 (× 2 ms) 1 C165 Input terminal response time 6 [Input [6] resp.time] 0 to 200 (× 2 ms) 1 C166 Input terminal response time 7 [Input [7] resp.time] 0 to 200 (× 2 ms) 1 C167 Input terminal response time 8 [Input [8] resp.time] 0 to 200 (× 2 ms) 1 C168 FW terminal response time 0 to 200 (× 2 ms) [Input [FW] resp.time] 1 C169 Multi-step speed/ position determination time [Multi-spd determ.time] 0 0 to 200 (× 10 ms) Changes during operation Unit Page No ms 4-108 No ms 4-16 4-137 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-36 Appendix Others Input terminal response Parameter No. Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page No  4-111 No  4-111 4-113 4-115 No kW H001 00: OFF (Disabled) Auto-tuning selection 01: ON (STOP) [Auto-tuning select] 02: ON (Rotation) 00 H002 Motor parameter selection [Motor data select] 00 H202 * 2nd motor parameter selection [Motor data selectM2] H003 Motor capacity selection [Motor capacity] H203 * 2nd motor capacity selection [Motor capacity-M2] H004 Motor pole number selection [Motor poles] H204 * 2nd motor pole number selection [Motor poles-M2] H005 Speed response [M.speed const] 00: Standard motor parameter 01: Auto-tuning parameter 02: Auto-tuning parameter (online auto-tuning enabled) 00 Factory default Control parameter 0.20 to 160.0 Factory default 4 2/4/6/8/10 Appendix H205 H006 Stabilization parameter [M.stabil.const] H206 * 2nd stabilization parameter [M.stabil.const-M2] H306 * 3rd stabilization parameter [M.stabil.const-M3] No Pole Yes  4-89 4-92 Yes  4-120 4 1.590 0.001 to 80.000 * 2nd speed response [M.speed const-M2] 4-19 4-111 4-115 4-118 1.590 100 0 to 255 100 100 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-37 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting No  No  No mH No A Depends on the motor capacity. H020 Motor parameter R1 [M.const R1] H220 * 2nd motor parameter R1 [M.const R1-M2] Depends on the motor capacity. H021 Motor parameter R2 [M.const R2] Depends on the motor capacity. H221 * 2nd motor parameter R2 [M.const R2-M2] Depends on the motor capacity. H022 Motor parameter L [M.const L] Depends on the motor capacity. H222 * 2nd motor parameter L [M.const L-M2] Depends on the motor capacity. H023 Motor parameter IO [M.const IO] Depends on the motor capacity. H223 * 2nd motor parameter IO [M.const IO-M2] Depends on the motor capacity. Motor parameter J [M.const J] Depends on the motor capacity. 0.001 to 65.535 0.001 to 65.535 Control parameter Unit 0.01 to 655.35 0.01 to 655.35 Page 4-115 Appendix Changes during operation 4-115 H024 0.001 to 9999.000 H224 * 2nd motor parameter J [M.const J-M2] No kgm2 Depends on the motor capacity. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-38 Appendix-1 Parameter List Appendix Control parameter Parameter No. Function name H030 Motor parameter R1 (auto-tuning data) [M.const R1 (A.Tune)] H230 * 2nd motor parameter R1 (auto-tuning data) [M.const R1-M2 (A.Tune)] H031 Motor parameter R2 (auto-tuning data) [M.const R2 (A.Tune)] H231 * 2nd motor parameter R2 (auto-tuning data) [M.const R2-M2 (A.Tune)] H032 Motor parameter L (auto-tuning data) [M.const L (A.Tune)] H232 * 2nd motor parameter L (auto-tuning data) [M.const L-M2 (A.Tune)] H033 Motor parameter Io (auto-tuning data) [M.const IO (A.Tune)] H233 * 2nd motor parameter Io (auto-tuning data) [M.const IO-M2 (A.Tune)] H034 Motor parameter J (auto-tuning data) [M.const J (A.Tune)] H234 * 2nd motor parameter J (auto-tuning data) [M.const J-M2 (A.Tune)] Monitor or data range Default setting Changes during operation Unit No  No  No mH No A No kgm2 Page Depends on the motor capacity. 0.001 to 65.535 Depends on the motor capacity. Depends on the motor capacity. 0.001 to 65.535 Depends on the motor capacity. Depends on the motor capacity. 0.01 to 655.35 Depends on the motor capacity. 4-111 4-115 Depends on the motor capacity. 0.01 to 655.35 Depends on the motor capacity. Depends on the motor capacity. 0.001 to 9999.000 Depends on the motor capacity. * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-39 Appendix-1 Parameter List Parameter No. Function name Monitor or data range Default setting Unit Yes  Yes  Yes  Yes % H050 PI proportional gain [PI P gain] H250 * 2nd PI proportional gain [PI P gain-M2] H051 PI integral gain [PI I gain] H251 *2nd PI integral gain [PI I gain-M2] 100.0 H052 P proportional gain [P gain] 1.00 H252 *2nd P proportional gain [P gain-M2] H060 Limit at 0 Hz [0Hz Speed limit] H260 * 2nd limit at 0 Hz [0Hz Speed limit-M2] 100.0 H061 Boost amount at SLV startup, 0 Hz [Bst HiTQ start SLV] 50 H261 * 2nd boost amount at 0 to 50 SLV startup, 0 Hz [Bst HiTQ start SLVM2] H070 For PI proportional gain switching [PI P gain term.] 0.0 to 1000.0 H071 For PI integral gain switching [PI I gain term.] 0.0 to 1000.0 H072 For P proportional gain switching [P gain term.] 0.00 to 10.00 1.00 Yes  H073 Gain switching time [Gain switching time] 0 to 9999 100 Yes ms Page 100.0 0.0 to 1000.0 100.0 100.0 0.0 to 1000.0 Control parameter Changes during operation 0.01 to 10.00 4-89 4-92 1.00 100.0 0.0 to 100.0 4-117 Yes % 100.0 Yes  100.0 Yes  50 Appendix 4-89 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-40 Appendix-1 Parameter List Parameter No. Function name Monitor or data range P001 Operation selection at option 1 error [Error mode OP1 card] P002 Operation selection at option 2 error [Error mode OP2 card] 00: Trip 01: RUN (Continues operation) P011 Encoder pulses [FB Encoder PPR] 128 to 65535 00: Trip 01: RUN (Continues operation) Default setting Changes during operation Unit 00 No  Page Appendix Options 4-111 00 No  1024 No Pulse 4-124 4-133 4-134 P012 00: ASR (speed control mode) V2 control mode 01: APR (pulse train position control mode) selection 02: APR2 (absolute position control mode) [Control pulse setting] 03: HAPR (High resolution absolute position control mode) 00 No  4-124 4-136 P013 Pulse train mode selection [Pulse train mode] 00: Mode 1 01: Mode 2 02: Mode 3 00 No  4-127 P014 Orientation stop position [Home search stop] 0 to 4095 0 No  P015 Orientation speed Starting frequency to Max. frequency (upper setting limit: 120.0) [Home search speed] 5.00 No Hz P016 Orientation direction setting [Home search direction] 00 No  00: FWD (Forward side) 01: REV (Reverse side) 4-134 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-41 Appendix-1 Parameter List Function name Monitor or data range Default setting Changes during operation Unit Page 5 No Pulse 4-127 4-134 0.00 No s 4-127 4-134 P017 Position ready range setting 0 to 10000 [Home search range] P018 Position ready delay time setting [Home search delay] 0.00 to 9.99 P019 Electronic gear setting position selection [E.gear position] 00: FB (Position feedback side) 01: REF (Position command side) 00 Yes  P020 Electronic gear ratio numerator [E.gear ratio-Num.] 1 to 9999 1 Yes  P021 Electronic gear ratio denominator [E.gear ratio-Den.] 1 to 9999 P022 Position control feedforward gain [Feed-FW gain] 0.00 to 655.35 4-128 4-129 1 Yes  0.00 Yes  0.50 Yes rad/s 4-124 4-128 4-129 4-134 4-136 Position bias amount -2048 to 2048 [Position bias] 0 Yes rad/s 4-128 P025 Secondary resistance compensation 00: OFF (Disabled) enable/disable 01: ON (Enabled) selection [Temp.comp. Therm] 00 No  4-114 P026 Overspeed error detection level 0.0 to 150.0 [OverSpeed err level] 135.0 No % 5-7 P027 Speed deviation error detection level 0.00 to 120.00 [SpeedDev. Err level] 7.50 No Hz 4-124 P028 Motor gear ratio numerator [M.gear ratio-num] 1 No  P029 Motor gear ratio denominator [M.gear ratio-den] 1 to 9999 1 No  P031 Acceleration/ deceleration time input type [Acc/Dec time source] 00: OPE (Digital Operator) 01: Option 1 02: Option 2 03: EzSQ (Drive Programming) 00 No  4-8 P032 Orientation stop 00: OPE (Digital Operator) position input type 01: Option 1 [Positioning cmd src.] 02: Option 2 00 No   P023 Position loop gain [Position loop gain] P024 0.00 to 100.00 1 to 9999 4-133 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-42 Appendix Options Parameter No. Appendix-1 Parameter List Options Appendix Parameter No. Function name Monitor or data range Default setting Changes during operation Unit 00 No  Page P033 Torque reference input selection [TRQ cmd source] 00: O (Terminal O) 01: OI (Terminal OI) 02: O2 (Terminal O2) 03: OPE (Digital Operator) 06: Option 1 07: Option 2 P034 Torque reference setting [TRQ cmd setting] 0 to 200 (0.4 to 55 kW) 0 to 180 (75 to 132 kW) 0 Yes % P035 Polarity selection at torque reference via O2 [O2 TRQ polarity] 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00 No  P036 Torque bias mode [TRQ bias mode] 00: OFF (None) 01: OPE (Digital Operator) 02: O2 (Terminal O2) 05: Option 1 06: Option 2 00 No  P037 Torque bias value [TRQ bias value] -200 to 200 (0.4 to 55 kW) -180 to 180 (75 to 132 kW) 0 Yes % P038 Torque bias polarity selection [TRQ bias polarity] 00: Sign (Signed) 01: Direction (Depends on the RUN direction) 00 No  P039 Speed limit value in torque control (forward) [TRQ SpeedLmt (FW)] 0.00 to Maximum frequency 0.00 Yes Hz P040 Speed limit value in torque control (reverse) [TRQ SpeedLmt (RV)] 0.00 to Maximum frequency 0.00 Yes Hz P044 DeviceNet comm Watch dog timer [DeviceNet comm WDT] 0.00 to 99.99 1.00 No s  P045 00: Trip Operation setting at 01: Decel-Trip (Trip after deceleration stop) communications error 02: Ignore [Act. Network com 03: Free RUN loss] 04: Decel-Stop (Deceleration stop) 00 No   1 No   4-126 4-126 4-127 4-126 P046 Instance Number [Instance No.] 0: Basic speed I/O 1: Extended speed I/O 2: Extended speed and Torque control 3: Special I/O 4: Extended control I/O 5: Extended control I/O and multifunction I/O monitor 6: Flexible format 7: Extended speed and Acceleration control 8-20: Not used * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-43 Appendix-1 Parameter List Options Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page P048 Operation setting at idle mode detection [Act. Network idle] 00: Trip 01: Decel-Trip (Trip after deceleration stop) 02: Ignore 03: Free RUN 04: Decel-Stop (Deceleration stop) 00 No   P049 Polarity setting for rotation speed [Poles of RPM] 0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/ 32/34/36/38 0 No   P055 Pulse train frequency scale 1.0 to 50.0 [Pulse FQ scale] 25.0 No kHz P056 Pulse train frequency filter time constant 0.01 to 2.00 [Pulse FQ filter] 0.10 No s P057 Pulse train frequency bias amount -100 to 100 [Pulse FQ bias] P058 Pulse train frequency limit 0 to 100 [Pulse FQ limit] P060 Multi-step position command 0 [Position set 0] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P061 Multi-step position command 1 [Position set 1] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P062 Multi-step position command 2 [Position set 2] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P063 Multi-step position command 3 [Position set 3] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P064 Multi-step position command 4 [Position set 4] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 P065 Multi-step position command 5 [Position set 5] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P066 Multi-step position command 6 [Position set 6] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P067 Multi-step position command 7 [Position set 7] Position range specification (reverse side) to Position range specification (forward side) -268435455 to 268435455 0 P068 00: Low speed Zero return mode 01: High speed 1 [Homing mode select] 02: High speed 2 00 Yes  P069 Zero return direction selection [Homing direction] 00 Yes  0 No % 100 No % Yes  Appendix Absolute position control 4-144 0 4-136 00: FWD (Forward side) 01: REV (Reverse side) * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-44 Appendix-1 Parameter List Absolute position control Parameter No. Monitor or data range Default setting Changes during operation Unit 0.00 Yes Hz 0.00 Yes Hz P070 Low-speed zero return frequency [LowSpeed homing FQ] P071 High-speed zero return frequency 0.00 to Maximum frequency [HiSpeed homing FQ] P072 Position range specification 0 to 268435455 (at P012 = 02) (forward) 0 to 1073741823 (at P012 = 03) [Position range FWD] 268435455 Yes  P073 Position range specification -268435455 to 0 (at P012 = 02) (reverse) -1073741823 to 0 (at P012 = 03) [Position range REV] -268435455 Yes  0.00 to 10.00 Page 4-136 Teaching selection [Teaching select] 00: X00 (Multi-step position command 0 (P060)) 01: X01 (Multi-step position command 1 (P061)) 02: X02 (Multi-step position command 2 (P062)) 03: X03 (Multi-step position command 3 (P063)) 04: X04 (Multi-step position command 4 (P064)) 05: X05 (Multi-step position command 5 (P065)) 06: X06 (Multi-step position command 6 (P066)) 07: X07 (Multi-step position command 7 (P067)) 00 Yes  P100 to P131 Drive Program parameter U(00) to U(31) [EzSQ parameter U(00)] to [EzSQ parameter U(31)] 0 to 65535 0 Yes   P160 to P169 Option I/F cmd W register 1 to 10 [Op I/F cmd W reg.1] 0000 to FFFF to [Op I/F cmd W reg.10] 0000 Yes   P170 to P179 Option I/F cmd R register 1 to 10 [Op I/F cmd R reg.1] to [Op I/F cmd R reg.10] 0000 to FFFF 0000 Yes   P180 Profibus node address [Profibus Node adrs] 0 to 125 0 No   P181 Profibus clear mode 00: Clear [Profibus CLR mode] 01: Last value 00 No   P074 Appendix Function name 4-137 * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-45 Appendix-1 Parameter List Function name Monitor or data range Default setting Changes during operation Unit Page P182 Profibus Map selection [Profibus Map selection] 00: PPO 01: Conventional 02: Flexible Mode 00 No   P185 CANOpen Node address [CANOpen Node adrs] 0 to 127 0 No   P186 CANOpen communication speed [CANOpen com speed] 00: Auto 01: 10Kbps 02: 20Kbps 03: 50Kbps 04: 125Kbps 05: 250Kbps 06: 500Kbps 07: 800Kbps 08: 1Mbps 06 No   P190 CompoNet node address [CompoNet Node address] 0 to 63 0 No   P192 DeviceNet node address [DeviceNet MAC ID] 0 to 63 63 No   P195 ML2 frame length [ML2 frame length] 00: 32 bytes 01: 17 bytes 00 No   P196 ML2 node address [ML2 node address] 21 to 3E 21 No   U001 User 1 selection no/d001 to P196 no U002 User 2 selection no/d001 to P196 no U003 User 3 selection no/d001 to P196 no U004 User 4 selection no/d001 to P196 no U005 User 5 selection no/d001 to P196 no U006 User 6 selection no/d001 to P196 no Yes  4-53 U007 User 7 selection no/d001 to P196 no U008 User 8 selection no/d001 to P196 no U009 User 9 selection no/d001 to P196 no U010 User 10 selection no/d001 to P196 no U011 User 11 selection no/d001 to P196 no U012 User 12 selection no/d001 to P196 no * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. App-46 Appendix User parameter Parameter No. Appendix-2 Product Life Curve Appendix-2 Product Life Curve Ambient temperature (°C) 24-hour power supply/day 50 40 30 20 10 0 -10 1 2 3 4 5 6 7 8 9 10 Capacitor life (year) Appendix Note 1: Ambient temperature refers to the temperature measured at the location approximately 5 cm from the bottom center of the Inverter. (atmospheric temperature) It refers to the temperature inside if the Inverter is stored in an enclosure. Note 2: The smoothing capacitor, which will deteriorate because of the chemical reaction caused by the temperatures of the parts, should normally be replaced once every 10 years (which is the expected design life, and not guaranteed). However, if the ambient temperature is high, or the Inverter is used with a current exceeding the rated current, for example, under overload conditions, its life will be significantly shortened. App-47 Appendix-3 Life Alarm Output Appendix-3 Life Alarm Output •When the product life becomes close to the end for the parts including the on-board smoothing capacitor or cooling fan, but excluding the main circuit smoothing capacitor, an alarm can be output through the self-diagnostic function. Use it as a reference of the parts replacement period. For details, refer to "Life Assessment Monitor [d022]" (page 4-5), "Multi-function Pulse Counter (PCNT, PCC)" (page 4-94), or "Multi-function Output Terminal Contact Selection" (page 4-96). This alarm is output through the self-diagnosis based on the expected design life (not a guaranteed value). Therefore, it has a margin of error depending on your environment or operation conditions. Appendix App-48 Appendix-4 EC Declaration of Conformity Appendix Appendix-4 EC Declaration of Conformity App-49 Appendix-4 EC Declaration of Conformity Appendix App-50 Index Index Numerics D 0-Hz sensorless vector control .............................. 4-117 2-step acceleration/deceleration.............................. 4-37 3-wire input function ................................................ 4-88 data comparison display................................. 4-53, 4-55 DC injection braking ................................................ 4-24 DC voltage monitor.................................................... 4-7 deceleration time 2 .................................................. 4-37 derating.................................................................... 4-68 digital operator.................................................. 2-22, 3-3 display selection ............................................. 3-18, 4-53 DWN ........................................................................ 4-90 A acceleration stop ..................................................... 4-30 acceleration time 2 .................................................. 4-37 acceleration/deceleration pattern ............................ 4-38 acceleration/deceleration time................................... 4-8 ADD ......................................................................... 4-41 AHD ......................................................................... 4-93 AL ............................................................................ 4-95 alarm code output.................................................. 4-101 allowable momentary power interruption time ......... 4-42 AM .................................................................. 2-7, 4-110 AMI ................................................................. 2-7, 4-110 analog command hold function................................ 4-93 automatic energy-saving operation function............ 4-36 automatic optimum acceleration/deceleration ......... 4-36 automatic torque boost ............................................ 4-20 B base frequency ........................................................ basic display ............................................................ BER ......................................................................... binary operation....................................................... bit operation............................................................. BOK ......................................................................... brake control............................................................ BRK ......................................................................... 4-11 4-56 4-76 4-17 4-18 4-76 4-76 4-76 C capacitor life warning............................................. 4-103 carrier frequency...................................................... 4-68 CAS ......................................................................... 4-89 commercial switching .............................................. 4-85 communication function......................................... 4-145 constant torque characteristics (VC) ....................... 4-21 control circuit terminal................................................ 2-6 control gain switching .............................................. 4-89 control method......................................................... 4-21 cooling fan control ................................................... 4-74 cooling fan speed drop signal................................ 4-104 current position monitor ............................................. 4-6 Index-1 E electronic gear ....................................................... 4-129 electronic thermal monitor ......................................... 4-7 EMC....................................................... 2-14, 2-15, 2-16 emergency shutoff .............................................. 2-8, 2-9 end frequency.......................................................... 4-14 end ratio................................................................... 4-14 excess speed............................................................. 5-7 EXT.......................................................................... 4-84 extended function mode .......................................... 3-20 external analog input ............................................... 4-12 external DC injection braking................................... 4-25 external thermistor................................................... 4-75 external trip (EXT) ................................................... 4-84 F F/R........................................................................... 4-88 fatal fault signal...................................................... 4-107 fault monitor............................................................... 4-7 FBV.......................................................................... 4-34 FC............................................................................ 2-20 FE ..................................................................... 2-6, 2-20 feedback .................................................................. 4-32 feedback option ..................................................... 4-123 FI ............................................................................. 2-20 fin overheat warning .............................................. 4-105 fin temperature monitor ............................................. 4-4 FOC ....................................................................... 4-119 forced operator ........................................................ 4-91 forced terminal......................................................... 4-93 forward run signal .................................................. 4-107 FR.......................................................................... 4-105 free-run stop ............................................................ 4-71 free-run stop selection and stop selection ............... 4-70 frequency addition function...................................... 4-41 frequency arrival signal............................................ 4-98 frequency conversion coefficient ............................... 4-2 frequency jump ........................................................ 4-30 frequency limit ......................................................... 4-28 lower limit ......................................................... 4-28 upper limit ........................................................ 4-28 Index frequency matching ................................................. 4-71 frequency pull-in restart .................................. 4-43, 4-45 frequency reference selection ................................. 4-10 FRS ......................................................................... 4-71 F-TM ........................................................................ 4-93 function mode ............................................................ 4-8 FV ............................................................................ 2-20 FW ............................................................................. 2-8 FWR ...................................................................... 4-107 H high-torque multi-operation.................................... 4-119 I initial screen............................................................. 4-56 initialization .............................................................. 4-70 input power monitor ................................................... 4-4 internal DC injection braking........................... 4-26, 4-28 IP .................................................................... 4-44, 4-45 J JG ............................................................................ 4-18 jogging operation ..................................................... 4-18 K KHC ........................................................................... 4-4 L LAC................................................................... 4-9, 4-40 LAD................................................................... 4-9, 4-80 life assessment monitor.................................. 4-5, 4-103 light load detection signal ...................................... 4-106 LOC ....................................................................... 4-106 LOG1 to LOG6 ...................................................... 4-102 M main circuit terminal.......................................... 2-6, 2-14 manual torque boost................................................ 4-20 maximum frequency ................................................ 4-12 MJA ....................................................................... 4-107 momentary power interruption non-stop.................. 4-60 momentary power interruption/undervoltage trip during stop selection.................................................. 4-42, 4-44 MP ......................................................................... 4-109 multi-function input monitor ....................................... 4-2 multi-function input terminal selection ..................... 4-79 multi-function output monitor ..................................... 4-2 multi-function output terminal .................................. 4-95 N NDc........................................................................ 4-104 no............................................................................. 4-79 O OD ........................................................................... 4-34 offline auto-tuning .................................................. 4-111 OHF ....................................................................... 4-105 OL, OL2 ................................................................... 4-50 OLR ......................................................................... 4-49 online auto-tuning .................................................. 4-113 ONT ......................................................................... 4-52 OPE ......................................................................... 4-91 operation frequency function ................................... 4-41 operation method....................................................... 3-3 operation ready signal ........................................... 4-106 operation selection during option error .................. 4-111 orientation function ................................................ 4-134 OTQ....................................................................... 4-100 output current monitor ............................................... 4-1 output frequency monitor.................................... 4-1, 4-2 output frequency setting/monitor ............................... 4-8 output signal delay/hold......................................... 4-108 output signal logic operation.................................. 4-102 output torque monitor ................................................ 4-3 output voltage gain .................................................. 4-24 output voltage monitor ............................................... 4-3 overcurrent suppression .......................................... 4-51 overload limit ........................................................... 4-49 overload warning ..................................................... 4-49 overtorque ............................................................. 4-100 overvoltage protection function during deceleration 4-78 P P/PI switching .......................................................... 4-92 P24 ............................................................................ 2-7 phase loss protection............................................... 4-46 PID........................................................................... 4-31 PID feedback value monitor ...................................... 4-1 PIDC ........................................................................ 4-35 power ON time........................................................... 4-4 power recovery restart prevention ........................... 4-84 PPI........................................................................... 4-92 preliminary excitation............................................. 4-119 pulse train frequency input .................................... 4-144 Index-2 Index R T real frequency monitor............................................... 4-3 reduced voltage startup ........................................... 4-53 relay output terminals .............................................. 4-97 reset......................................................................... 4-87 retry selection .......................................................... 4-42 reverse rotation prevention...................................... 4-59 reverse run signal .................................................. 4-107 RNT ......................................................................... 4-52 rotation direction limit selection ............................... 4-52 rotation direction selection......................................... 4-9 RS.............................................................................. 2-9 RUN......................................................................... 4-98 RUN command selection......................................... 4-11 RUN direction monitor ............................................... 4-1 RUN direction selection ............................................. 4-9 RV................................................................... 2-11, 4-79 RVR ....................................................................... 4-107 test run....................................................................... 3-4 thermistor................................................................. 4-75 THM......................................................................... 4-48 TL ............................................................................ 4-58 torque bias monitor.................................................... 4-3 torque boost............................................................. 4-19 torque LADSTOP function ....................................... 4-59 torque limit ............................................................... 4-57 torque reference monitor ........................................... 4-3 total RUN time ........................................................... 4-4 trip monitor display .................................................... 5-9 trip retry ................................................................... 4-42 TRQ ......................................................................... 4-95 TRQ1, TRQ2 ........................................................... 4-58 S SC............................................................................ 2-20 secondary resistance compensation ..................... 4-114 sensor vector control ............................................. 4-125 sensorless vector control....................................... 4-116 servo ON ............................................................... 4-143 SF1 to SF7 .............................................................. 4-18 signal during RUN ................................................... 4-98 sink logic.................................................................. 2-21 slide switch .............................................................. 2-10 soft lock ................................................................... 4-51 SON....................................................................... 4-143 source logic ............................................................. 2-21 special reduced torque characteristics .................... 4-22 STA.......................................................................... 4-88 stabilization parameter .......................................... 4-120 start frequency......................................................... 4-14 start ratio.................................................................. 4-14 start selection .......................................................... 4-14 starting contact signal............................................ 4-105 starting frequency .................................................... 4-68 stop key selection .................................................... 4-70 stop selection.................................................. 4-70, 4-71 STP.......................................................................... 4-88 synchronous operation .......................................... 4-130 Index-3 U UDC......................................................................... 4-90 UP............................................................................ 4-90 UP/DOWN function.................................................. 4-90 user parameter ........................................................ 4-57 user selection .......................................................... 4-53 USP ......................................................................... 4-84 UV................................................................... 4-45, 4-95 V V2 .......................................................................... 4-124 W WAF....................................................................... 4-104 wiring control circuit terminals ................................. 2-20 wiring the main circuit terminals .............................. 2-11 Z ZS .......................................................................... 4-101 OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 industrial.omron.eu Austria Tel: +43 (0) 2236 377 800 industrial.omron.at France Tel: +33 (0) 1 56 63 70 00 industrial.omron.fr Netherlands Tel: +31 (0) 23 568 11 00 industrial.omron.nl Spain Tel: +34 913 777 900 industrial.omron.es Belgium Tel: +32 (0) 2 466 24 80 industrial.omron.be Germany Tel: +49 (0) 2173 680 00 industrial.omron.de Norway Tel: +47 (0) 22 65 75 00 industrial.omron.no Sweden Tel: +46 (0) 8 632 35 00 industrial.omron.se Czech Republic Tel: +420 234 602 602 industrial.omron.cz Hungary Tel: +36 (0) 1 399 30 50 industrial.omron.hu Poland Tel: +48 (0) 22 645 78 60 industrial.omron.com.pl Switzerland Tel: +41 41 748 13 13 industrial.omron.ch Denmark Tel: +45 43 44 00 11 industrial.omron.dk Italy Tel: +39 02 32 681 industrial.omron.it Portugal Tel: +351 21 942 94 00 industrial.omron.pt Turkey Tel: +90 (0) 216 474 00 40 industrial.omron.com.tr Finland Tel: +358 (0) 207 464 200 industrial.omron.fi Middle East & Africa Tel: +31 (0) 23 568 11 00 industrial.omron.eu Russia Tel: +7 495 648 94 50 industrial.omron.ru United Kingdom Tel: +44 (0) 870 752 08 61 industrial.omron.co.uk Note: Specifications subject to change without notice. Cat. No. I560-E2-04
3G3RXA2004 价格&库存

很抱歉,暂时无法提供与“3G3RXA2004”相匹配的价格&库存,您可以联系我们找货

免费人工找货