0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
61FGPNBC24VDC

61FGPNBC24VDC

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Conductive Level Controller

  • 数据手册
  • 价格&库存
61FGPNBC24VDC 数据手册
Conductive Level Controller 61F-GPN-BT/-BC CSM_61F-GPN-BT_BC_DS_E_5_2 Battery (24 VDC) allows use in locations without AC power supply. AC sine-wave voltage between electrodes enables stable detection with no electric corrosion. • Outputs can be set to self-hold at ON or OFF using special circuits. • Adjustable sensitivity, with an operating resistance range of 0 to 100 kΩ, allows use for a wide variety of liquids. • Relay contact chattering conventionally caused by waves eliminated using open collector output, reducing contact wear. • Meets CE marking and is a UL recognized component. Refer to Safety Precautions for Floatless Level Controllers. Features The 61F can now run on DC power to allow energy savings, greater safety, and use in emergency situations. Combines DC Power Supply with AC Sensing Method AC sine-wave signals are sent to electrodes using a built-in DC-AC converter, preventing electric corrosion and ensuring safety. Supports Multi-channel Sensing Power supply circuits and detection circuits are isolated, allowing more than one Controller to be used in the same tank. Open Collector Output Signals can be used as direct input for a PLC. PNP output is also possible using the connection method. Oscillator circuit Detector circuit Upper limit Mid-point Control output is possible for upper limit, mid-point, and lower limit. Lower limit Same Wiring for Supply and Drainage Supply control and drainage control can be performed with the same wiring (short terminals 7 and 8 for supply control). This makes it easy to perform wiring and confirm connection. Chattering Load Drainage control Supply control Short-circuit Valve Pump Ordering Information Product name Conductive Level Controller Model number 61F-GPN-BT 24VDC 61F-GPN-BC 24VDC Open collector (NPN) Relay contact (SPST-NO) Front Socket PF113A-E Electrode Holder (See note.) Note: A variety of Holders are available to suit different types of application. For details, refer to 61F Floatless Level Controller (F030-E1-8). 1 61F-GPN-BT/-BC Specifications ■ Ratings 61F-GPN-BT Rated voltage 24 VDC Allowable voltage range 85% to 110% of the rated voltage Interelectrode voltage 5 VAC max. Operation resistance (See note 1.) Variable (0 to 100 kΩ) 61F-GPN-BC Error For scale of 0: +10 kΩ; For scale of 100: ±10 kΩ Release resistance 200% max. of the operation resistance Switching between supply and drainage Terminals 7 and 8 open: Automatic drainage operation Terminals 7 and 8 shorted: Automatic supply operation Output specifications Open collector (NPN) 30 VDC, 100 mA max. Leak current: 100 μA max. Relay output, SPST-NO 5 A, 240 VAC (Resistive load) 5 A, 30 VDC Life expectancy --- Electrical: 100,000 operations min. Mechanical: 20,000,000 operations min. Accessories Hold-down clip PFC-N8 Wiring distance (See note 2.) 100 m max. Note: 1. The 61F may not operate at resistance settings close to zero. Adjust the sensitivity to match actual usage conditions. 2. The figure for wiring distance above is for when 600-V 3-core cabtire cable with a cross-sectional area of 0.75 mm2 is used. ■ Characteristics Ambient operating temperature −10 to 55°C Ambient operating humidity 25% to 85% Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength (See note.) 2,000 VAC, 50/60 Hz for 1 minute Power consumption 2 W max. Response time Operating: 1.5 s max. Releasing: 3.0 s max. Approved standards UL61010-1, CAN/CSA C22.2 No.61010-1 EN61010-1 EN61326-1 Industrial electromagnetic environment Note: The dielectric strength is measured between power terminals and electrode terminals, power terminals and output terminals, and between electrode terminals and output terminals. Connections ■ Automatic Drainage Operation 61F-GPN-BT Open collector output OUT+ 11 5 OUT− 10 6 Relay contact output OUT+ 11 OUT− 10 Supply/ drainage selection terminals 7 8 4 E1 (See note.) 3 9 E2 Pump ON (OFF) Pump OFF (ON) E3 24 VDC Note: The part within the dotted-line box is for the 61F-GPN-BC (relay-output type) only. ■ Automatic Water Supply Operation Short terminals 7 and 8 for automatic water supply operation. (Operation shown in parentheses in the diagram above.) 2 61F-GPN-BT/-BC ■ Reading Signals for the Liquid Level Only (No Control) Only E1 and E3 are used. Output will turn ON when the liquid level reaches E1 if terminals 7 and 8 are open, and will turn OFF if terminals 7 and 8 are closed. Also, to take signals for liquid level at several points, use terminal 4 as a common for all of the Controllers and use terminal 5 of each Controller as an electrode. Note: If terminals 7 and 8 are shorted, operation of the 61F relay is “de-energizing” (i.e., energized normally and de-energized when liquid is present across the electrodes). Therefore, if the power supply connected across terminals 3 and 9 is interrupted, the output from terminals 10 and 11 will turn OFF, enabling detection of power interruptions. Dimensions 61F-GPN-BT/-BC Use a PFC-N8 Mounting Bracket to mount the Level Controller to a PF113A Rail-mounted Socket. PFC-N8 4 61F-GPN -BT/-BC 49.4 38 101 Approx. 80 70 84 83 PF113A (Order Separately) 4.5 6 t = 0.3 Note: PFC-N8 Mounting Bracket (provided with the Level Controller) Application Examples Drainage control for semiconductor wafer cleaning installations. Meet safety standards by using DC power supply for all devices in a panel. Liquid level control for waste-heat recovery boilers in co-generation systems. Applications ON Liquid level control for solar power generation systems. Liquid level control for remote regions without AC power supply. Battery OFF Cut costs by using the 61F in situations where ultrasonic/electrostatic capacity level controllers were used because only DC power supply was available. Number of controllers required: 2 1 3 61F-GPN-BT/-BC Safety Precautions Refer to Safety Precautions for Floatless Level Controllers. General Precautions Before using the Controller under conditions not described in the relevant documents or applying the Controller to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the Controller are sufficient for the systems, machines, and equipment and be sure to provide the systems, machines, and equipment with double safety-mechanisms. Safety Precautions In order to ensure safe operation, be sure to observe the following points. Correct Use Mounting Mount to a panel of thickness 1 to 5 mm. Do not mount the Controller in the following places. • Locations subject to strong vibrations or shocks. • Locations outside the specified temperature and humidity ranges, or locations prone to condensation. (The Controller detects high impedances. Do not use in locations subject to high humidity levels.) • Locations subject to dust. • Locations subject to corrosive gases (in particular, sulphurized gas or ammonia gas). • Outdoors, or in locations subject to direct sunlight. • Near devices that generate strong, high-frequency noise (e.g., high-frequency welders, machines). • Use a power supply voltage within the specified range. • Do not use the Controller in locations subject to flammable gases or objects. • Insert the Socket until it securely clicks into place. • Do not short the load connected to the output terminals. • Do not connect the power supply in reverse. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 4 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.
61FGPNBC24VDC 价格&库存

很抱歉,暂时无法提供与“61FGPNBC24VDC”相匹配的价格&库存,您可以联系我们找货

免费人工找货