0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A165CAM

A165CAM

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Switch Access Push Button Switch Square Case

  • 数据手册
  • 价格&库存
A165CAM 数据手册
Indicator M16 Cylindrical 16-dia. Indicator • Same basic design as the A16 Pushbutton Switch. • UL and cUL approved (File No. E41515). Model Number Structure Pushbutton Switches ■ Model Number Legend Completely Assembled The model numbers used to order sets of Units are illustrated below. One set comprises the Display, Case, Lamp, and Socket. (1) (2) (3) (4) (5) M 1 6 5 - T R - 24D - P (5) Terminal Type Symbol Terminal type No symbol Solder terminals P PCB terminals S Screw-Less Clamp (1) Degree of Protection Symbol No symbol 5 (4) Light Source Protection IP40 IP65 oil-resistant (2) Shape of Display Symbol Shape (3) Color of Display Symbol Color Red Symbol 12 Rectangular R A Square G T Round Y Yellow 3J Rectangular (3-way guard) PY Pure yellow 12D W White 24D A Blue J BA Square (24-mm square) Green Type 5 24 Operating voltage Rated voltage 5 VAC/VDC 6 VAC/VDC Incandescent 12 VAC/VDC lamp 24 VAC/VDC 14 VAC/VDC 28 VAC/VDC 5 ±5% VDC 5D LED 5 VDC 12 ±5% VDC 12 VDC 24 ±5% VDC 24 VDC Voltage Reduction Unit (24-V Built-in LED) Symbol T1 T2 Type LED Operating voltage Rated voltage 90 to 121 VAC/VDC 110 VAC/VDC 180 to 242 VAC/VDC 220 VAC/VDC Solder terminals are available only with 100-V models. The Voltage Reduction Unit is not available for models with PCB terminals. Indicator M16 G-127 Ordering Information ■ List of Models Ordering as a Set The model numbers used to order sets of Units are given in the following tables. One set comprises the Display, Case, Lamp, and Socket. M16@-J (Rectangular) Models Solder Terminal Models Appearance Lighting Operating voltage IP40 IP65 oil-resistant LED without Voltage Reduction Unit 5 VDC M16-J@-5D M165-J@-5D 12 VDC M16-J@-12D M165-J@-12D 24 VDC M16-J@-24D M165-J@-24D Incandescent lamp 5 VDC/VAC M16-J@-5 M165-J@-5 12 VDC/VAC M16-J@-12 M165-J@-12 24 VDC/VAC M16-J@-24 M165-J@-24 Display color symbol (See note.) R: red Y: yellow G: green A: blue W: white PY: Pure yellow M16@-A (Square) Models Solder Terminal Models Appearance Lighting Operating voltage IP40 IP65 oil-resistant LED without Voltage Reduction Unit 5 VDC M16-A@-5D M165-A@-5D 12 VDC M16-A@-12D M165-A@-12D 24 VDC M16-A@-24D M165-A@-24D Incandescent lamp 5 VDC/VAC M16-A@-5 M165-A@-5 12 VDC/VAC M16-A@-12 M165-A@-12 24 VDC/VAC M16-A@-24 M165-A@-24 Display color symbol (See note.) R: red Y: yellow G: green A: blue W: white PY: Pure yellow M16@-T (Round) Models Solder Terminal Models Appearance Lighting Operating voltage IP65 oil-resistant LED without Voltage Reduction Unit 5 VDC M16-T@-5D M165-T@-5D 12 VDC M16-T@-12D M165-T@-12D 24 VDC M16-T@-24D M165-T@-24D Incandescent lamp 5 VDC/VAC M16-T@-5 M165-T@-5 12 VDC/VAC M16-T@-12 M165-T@-12 24 VDC/VAC M16-T@-24 M165-T@-24 Note: Enter the desired color symbol for the Display in @. G-128 IP40 Indicator M16 Display color symbol (See note.) R: red Y: yellow G: green A: blue W: white PY: Pure yellow Ordering Individually Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not available as sets can be created using individual parts. Also, store the parts as spares for maintenance and repairs. Display (Refer to page 130.) Rectangular Square Round Note: Use IP40 Displays in combination with IP40 Sockets and use IP65 Displays in combination with IP65 Sockets. Case (Refer to page 131.) Note: Display Units, which are combinations of Displays and Cases, are also available. Pushbutton Switches Lighted Models Lamp (Refer to page 130.) LED Incandescent Lamp Neon Lamp Socket (Refer to page 131.) Solder Terminals (Without Voltage Reduction Unit) Note: Socket Units, which are combinations of Lamps and Sockets, are also available. Indicator M16 G-129 Display For LED-lighted Models Sealing IP40 Appearance Rectangular Square IP65 oil-resistant Round Rectangular Round Square Color of Display Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY A165L-TPY Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY Green A16L-JGY A16L-AGY A16L-TGY A165L-JGY A165L-AGY A165L-TGY White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.) Sealing IP40 Appearance Rectangular Square IP65 oil-resistant Round Rectangular Round Square Color of Display Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY Green A16L-JG A16L-AG A16L-TG A165L-JG A165L-AG A165L-TG White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA Round Rectangular Square Neon Lamps Sealing IP40 Appearance Rectangular Square IP65 oil-resistant Round Color of Display Red A16L-JRN A16L-ARN A16L-TRN A165L-JRN A165L-ARN A165L-TRN Green A16L-JGN A16L-AGN A16L-TGN A165L-JGN A165L-AGN A165L-TGN White A16L-JWN A16L-AWN A16L-TWN A165L-JWN A165L-AWN A165L-TWN Lamp LED Color Operating voltage 5 VDC Red A16-5DSR 12 VDC A16-12DSR 24 VDC A16-24DSR Yellow A16-5DSY A16-12DSY A16-24DSY Green A16-5DSG A16-12DSG A16-24DSG White (See note.) A16-5DSW A16-12DSW A16-24DSW Blue A16-5DA A16-12DA A16-24DA Note: Use the white LED when the required illumination color is white or pure yellow. Incandescent Lamp Operating voltage Model G-130 Indicator M16 5 VAC/VDC A16-5 12 VAC/VDC A16-12 24 VAC/VDC A16-24 Neon Lamp Color of lamp Color of Display Operating voltage 100 VAC 200 VAC Red White, red A16-1NRN A16-2NRN Green Green A16-1NGN A16-2NGN Case Appearance Classification IP40 Model number Rectangular IP65 oil-resistant A16-CJM Square A16-CAM Round A16-CTM Rectangular A165-CJM Square A165-CAM Round A165-CTM Socket Appearance Classification Model number Solder terminals M16-0 PCB terminals M16-0P Screw-Less Clamp M16-S Solder terminals Solder terminals Voltage-reduction lighting Screw-Less Clamp 100 V M16-T1 100 V M16-T1-S 200 V M16-T2-S Pushbutton Switches Specifications ■ Approved Standards Agency UL, cUL (See note.) Standards UL508 File No. E41515 Note: cUL: CSA, C22.2 No. 14 ■ Ratings Super-bright LED Rated voltage Rated current Incandescent Lamp Operating voltage Built-in limiting resistance 5 VDC 30 mA (15 mA) 5 VDC ±5% 33 Ω (68 Ω) 12 VDC 15 mA 12 VDC ±5% 270 Ω (560 Ω) 24 VDC 10 mA 24 VDC ±5% 1,600 Ω (2,000 Ω) Note: The values in parentheses are for blue Pushbuttons. Rated voltage Rated current Operating voltage 6 VAC/VDC 60 mA 5 VAC/VDC 14 VAC/VDC 40 mA 12 VAC/VDC 28 VAC/VDC 24 mA 24 VAC/VDC Neon Lamp Rated voltage Rated current Operating voltage 110 VAC 1.5 mA 100 VAC ±10% 220 VAC 1.5 mA 200 VAC ±10% ■ Characteristics Ambient operating temperature −10°C to 55°C (with no icing or condensation) Ambient operating humidity 35% to 85% Ambient storage temperature −25°C to 65°C Note: Characteristics not provided above are the same as those for the A16. Indicator M16 G-131 Screw-less Clamp Item Screw-less Clamp Recommended wire size 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire Usable wires and ten- Twisted wire sile strength Solid wire 0.3 mm2 0.5 mm2 0.75 mm2 1.25 mm2 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. --- 10 N 20 N 30 N 40 N Tensile strength Length of exposed wire 10 ±1 mm Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Refer to page 134 for details of panel cutout dimensions. Rectangular Square M16-J M16-A Packing (t0.5) Solder terminals Packing (t0.5) Solder terminals 14.6 dia.18 dia. 14.6 dia. 18 dia. Lamp terminals Lamp terminals Mounting nut Lock ring Mounting nut Lock ring Round M16-T Packing (t0.5) M16 × 1 Solder terminals 18 dia. 15.1 dia. 14.6 dia. 18 dia. Lamp terminals Terminal Hole Dimensions Lamp terminals 14.6 dia. 18 dia. Mounting nut Lock ring G-132 Indicator M16 Rectangular The rectangular model is given here as a representative example. Lamp terminals are provided even for non-lighting applications. M16@-P PCB terminals 28.3 9.5 26.4 6 23.1 Panel Cutouts 21.1 10.8 16+0.2 0 dia. 4 24 min. 2.5 18.4 20.4 6.3 0.5 24 min. Lock ring Mounting ring 18 4.85 12.4 18.6 15.1 0.5 Recommended panel thickness: 0.5 to 3.2 mm 21 Packing (t0.5) (for oil-resistant IP65 only) 24 Rectangular M16@-T1, T2 Voltage-reduction lighting, solder terminals Panel Cutouts dia. 25 min. Display Packing (t0.5) (for oil-resistant IP65 only) 23 min. (Dimension A) Marking face Case Lock ring Mounting ring Socket Recommended panel thickness: 0.5 to 3.2 mm Rectangular M16@-S Screw-Less Clamp Socket dismounting lever Lock ring Mounting ring Packing (t0.5) (for oil-resistant IP65 only) Indicator M16 G-133 Pushbutton Switches Direction-indication arrow 16+0.2 0 ■ Terminal Arrangement Solder Terminals Screw-Less Clamp Bottom View Voltage-reduction Lighting Bottom View Black Bottom View Side with TOP indicated Side with TOP indicated Note: The L+ is not shown on the Socket Unit. Red Note: Voltage-reduction lighting models with Screw-Less Clamps (A16L-@T1-2S, A16L-@T2-2S) incorporate voltage-reduction circuits. ■ Panel Cutouts Solder Terminals Solder Terminals Screw-Less Clamp Rectangular M16@-J Square M16@-A Round M16@-T Rectangular M16@-S (Top View) (Top View) (Top View) 16+0.2 0 dia. 16+0.2 0 dia. 16+0.2 0 dia. 24 min. 25 min. 19 min. 19 min. 19 min. Note: 1. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be 0.5 to 2 mm. 2. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. Installation Refer to the Installation section for the A16. G-134 Indicator M16 32 min. (Dimension A) Precautions Refer to the Technical Information for Pushbutton Switches (Cat. No. A143) and the Precautions section for the A16. ■ Correct Use Mounting Wiring When mounting the Case onto the Socket Unit, ensure that the orientation is correct. Perform mounting with the • mark on the Case and the TOP mark on the Socket Unit facing in the same direction. When using stranded wire, gather the ends of the strands together before wiring. TOP mark When wiring, insert the wire until it comes into contact with something. After wiring is completed, pull on the wires to confirm that they are connected securely. After wiring, ensure that continuous pressure is not applied to the terminals. Refer to internal connections diagrams and confirm the terminal numbers before performing wiring. Case Socket Unit Screw-Less Clamps Mounting Procedure 1. Strip a length of 10 mm off the end of the wire (allowable range: 10±1 mm). 2. Bunch wire strands together and straighten them. 3. Insert the wire into the insertion hole while pressing the release button at the side of the hole. (Using a precision screwdriver is recommended.) 4. Let go of the release button to lock the wire into place. 5. After locking, pull on the wire gently to confirm that it is securely locked. Removing Procedure Remove wires by pulling them while pressing the release button. Note: When reusing wires that have already been locked, cut off the end of the wire and strip the wire again before using. Indicator M16 G-135 Pushbutton Switches • mark ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. A127-E1-02 G-136 In the interest of product improvement, specifications are subject to change without notice. Indicator M16
A165CAM 价格&库存

很抱歉,暂时无法提供与“A165CAM”相匹配的价格&库存,您可以联系我们找货

免费人工找货