A3PJ-5712-12E

A3PJ-5712-12E

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    A3PJ-5712-12E

  • 数据手册
  • 价格&库存
A3PJ-5712-12E 数据手册
Lighted Pushbutton Switch (Square) A3P CSM_A3P_DS_E_8_3 Large Square-bodied Lighted Pushbutton Switches • Excellent operating sensitivity. • Excellent illumination with even surface brightness. • Three-color models (green, orange, red; chameleon lighting) included in lineup. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 22. List of Models Model Appearance 52 max. 6.7 A3PJ (Rectangular) 25 32 52 max. 6.7 A3PA (Square) 25 25 6.4 52 max. A3PT (Round) 32 dia. Note: The A3PJ is shown in the figure above as an example. ■ Specifications: Refer to page 12. ■ Panel cutout: Refer to page 19. ■ Dimensions: Refer to page 16. ■ Accessories, replacements, and tools: Refer to pages 10 to 11. ■ Precautions for correct use: Refer to page 22. 1 A3P Model Number Structure Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton, Lamp, and Switch. For more information, refer to Ordering Information (pages 3 to 5). Some forms may not be available for order depending on the combination of functions and specifications described below. Contact your OMRON sales representative for more detailed information. (1) (2) (3) (4) (5) A 3 P J - 90 B 1 1 - (1) Shape of Pushbutton Symbol Shape Rectangular Square Round (2) Switch Specifications Standard Load 24E R ................... Single screen (3) Screen Pattern Illumination-only models Symbol Screen pattern Symbol Operation Momentary A SPDT A B Alternate T C Momentary DPDT Momentary operaD Alternate tion: Self-resetting Alternate opera- Microload tion: Self-holding Symbol Operation Momentary E SPDT F Alternate Momentary G DPDT H Alternate J (6) Upper Lower • Standard Load 250 VAC, 3 A 30 VDC, 3 A • Microload 125 VAC, 0.1 A 30 VDC, 0.1 A Single screen 1 gray Chameleon *1 G Note: 1. The chameleon screen pattern is not available with A3PT models. 2. The chameleon screen pattern is only available with 12 or 24-VDC models. *1. With chameleon models, the whole screen lights red, green, or orange. When not lit, the display is white. Note: The available rectangular and square models are shown below. Select from among the individual products shown on page 8. (The square models are only available with horizontal 2-split screen models) Minimum applicable load 5 VDC, 1 mA Horizontal 2-split Vertical 2-split 4-split screen screen models screen models models • 3PDT models are also available. Select from among the individual products shown on page 9. (4) Case Color (5) Lighting (6) Color of Pushbutton Method For LED SymColor bol LED-lighted Models Symbol Color 1 Black (A3PJ and A3PA R Red Light Models Only) O orange 2 Horizontal 3-split Vertical 3-split screen models screen models Note: A3PT models are available in light gray only. Symbol 05E 12E 24E Rated voltage 5 VDC 12 VAC/VDC 24 VAC/VDC LED Lamplighted Models (A3PT Only) Symbol 05C 12C 24C G W K green white Chameleon • The chameleon screen pattern is not available with A3PT models. • The chameleon screen pattern is only available with 12 or 24-VDC models. Rated voltage 5 VDC 12 VDC 24 VDC • A3PJ and A3PA can also be ordered separately. Refer to page 8 for details. The above diagrams show the Switches with the " " mark facing down. Colored-illumination models up to the 4-split screen models are available as individual Units. Refer to page 6. “Colored-illumination” models operate in the way shown below: Unlit Lit White Color The built-in LED is colored. Number of LED Lamps Screen pattern Single screen A3PJ A3PA Models with built-in LED Horizontal 2-split screen A3PT 2 2 *2 Vertical 2-split screen Horizontal 3-split screen Vertical 3-split screen 4 *2 --- --- 4-split screen *2. These split screen models are available only as individual Units. They cannot be ordered as sets. 2 A3P Ordering Information Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp, and Switch. (Not all combinations are possible. Ask your OMRON representative for details.) Rectangular Models (Single Screen) (Single Screen) (1) A3PJ Standard Loads Contact type Standard load (250 VAC, 3 A; 30 VDC, 4 A) Operation Output Lighting LED SPDT Chameleon LED DPDT Chameleon Momentary operation (Self-resetting) Case color Alternate operation (Self-holding) Black Light gray Black Light gray 5 VDC A3PJ-90A11-05E(1) A3PJ-90A12-05E(1) A3PJ-90B11-05E(1) A3PJ-90B12-05E(1) 12 VAC/VDC A3PJ-90A11-12E(1) A3PJ-90A12-12E(1) A3PJ-90B11-12E(1) A3PJ-90B12-12E(1) 24 VAC/VDC A3PJ-90A11-24E(1) A3PJ-90A12-24E(1) A3PJ-90B11-24E(1) A3PJ-90B12-24E(1) 12 VDC A3PJ-90AG1-12EK --- A3PJ-90BG1-12EK A3PJ-90BG2-12EK 24 VDC A3PJ-90AG1-24EK A3PJ-90AG2-24EK A3PJ-90BG1-24EK A3PJ-90BG2-24EK 5 VDC A3PJ-90C11-05E(1) A3PJ-90C12-05E(1) A3PJ-90D11-05E(1) A3PJ-90D12-05E(1) 12 VAC/VDC A3PJ-90C11-12E(1) A3PJ-90C12-12E(1) A3PJ-90D11-12E(1) A3PJ-90D12-12E(1) A3PJ-90D12-24E(1) 24 VAC/VDC A3PJ-90C11-24E(1) A3PJ-90C12-24E(1) A3PJ-90D11-24E(1) 12 VDC A3PJ-90CG1-12EK A3PJ-90CG2-12EK A3PJ-90DG1-12EK --- 24 VDC A3PJ-90CG1-24EK A3PJ-90CG2-24EK A3PJ-90DG1-24EK A3PJ-90DG2-24EK Pushbutton color symbol R O G W * R O G W * Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PJ-90A11-24E R * You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details. Microloads Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A) Operation Output Lighting LED SPDT Chameleon LED DPDT Chameleon Momentary operation (Self-resetting) Case color Pushbutton color symbol Black Light gray 5 VDC A3PJ-90E11-05E(1) A3PJ-90E12-05E(1) 12 VAC/VDC A3PJ-90E11-12E(1) A3PJ-90E12-12E(1) 24 VAC/VDC A3PJ-90E11-24E(1) A3PJ-90E12-24E(1) 12 VDC A3PJ-90EG1-12EK 24 VDC A3PJ-90EG1-24EK 5 VDC A3PJ-90G11-05E(1) --- 12 VAC/VDC A3PJ-90G11-12E(1) A3PJ-90G12-12E(1) 24 VAC/VDC A3PJ-90G11-24E(1) A3PJ-90G12-24E(1) R O G W 12 VDC A3PJ-90GG1-12EK 24 VDC A3PJ-90GG1-24EK --- * --A3PJ-90EG2-24EK R O G W * Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PJ-90E11-24E R * You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details. Individual models: Refer to pages 7 to 11. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. (The Pushbutton, Lamp, and Switch can be ordered separately.) ■ Accessories: Refer to pages 10 to 11. 3 A3P Ordering Information Ordering as a Set ..................................The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp, and Switch. (Not all combinations are possible. Ask your OMRON representative for details.) Square Models (Single Screen) (Single Screen) (1) A3PA Standard Loads Contact type Standard load (250 VAC, 3 A; 30 VDC, 4 A) Operation Output Lighting LED SPDT Chameleon LED DPDT Chameleon Momentary operation (Self-resetting) Case color Black Alternate operation (Self-holding) Light gray Black Light gray 5 VDC A3PA-90A11-05E(1) A3PA-90A12-05E(1) A3PA-90B11-05E(1) A3PA-90B12-05E(1) 12 VAC/VDC A3PA-90A11-12E(1) A3PA-90A12-12E(1) A3PA-90B11-12E(1) A3PA-90B12-12E(1) 24 VAC/VDC A3PA-90A11-24E(1) A3PA-90A12-24E(1) A3PA-90B11-24E(1) A3PA-90B12-24E(1) 12 VDC A3PA-90AG1-12EK A3PA-90AG2-12EK A3PA-90BG1-12EK A3PA-90BG2-12EK 24 VDC A3PA-90AG1-24EK A3PA-90AG2-24EK A3PA-90BG1-24EK A3PA-90BG2-24EK 5 VDC A3PA-90C11-05E(1) A3PA-90C12-05E(1) A3PA-90D11-05E(1) A3PA-90D12-05E(1) 12 VAC/VDC A3PA-90C11-12E(1) A3PA-90C12-12E(1) A3PA-90D11-12E(1) A3PA-90D12-12E(1) 24 VAC/VDC A3PA-90C11-24E(1) A3PA-90C12-24E(1) A3PA-90D11-24E(1) A3PA-90D12-24E(1) 12 VDC A3PA-90CG1-12EK A3PA-90CG2-12EK A3PA-90DG1-12EK A3PA-90DG2-12EK 24 VDC A3PA-90CG1-24EK A3PA-90CG2-24EK A3PA-90DG1-24EK A3PA-90DG2-24EK Pushbutton color symbol R O G W * R O G W * Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PA-90A11-24E R * You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details. Microloads Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A) Operation Output Lighting LED SPDT Chameleon Momentary operation (Self-resetting) Case color Black 5 VDC A3PA-90E11-05E(1) A3PA-90E12-05E(1) 12 VAC/VDC A3PA-90E11-12E(1) A3PA-90E12-12E(1) 24 VAC/VDC A3PA-90E11-24E(1) A3PA-90E12-24E(1) 12 VDC A3PA-90EG1-12EK --- 24 VDC A3PA-90EG1-24EK A3PA-90EG2-24EK 5 VDC LED DPDT Chameleon Light gray --- --- 12 VAC/VDC A3PA-90G11-12E(1) A3PA-90G12-12E(1) 24 VAC/VDC A3PA-90G11-24E(1) A3PA-90G12-24E(1) 12 VDC A3PA-90GG1-12EK 24 VDC A3PA-90GG1-24EK --- Pushbutton color symbol R O G W * R O G W * Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PA-90E11-24E R * You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details. Individual models: Refer to pages 7 to 11. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. (The Pushbutton, Lamp, and Switch can be ordered separately.) ■ Accessories: Refer to pages 10 to 11. 4 A3P Ordering Information Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp, and Switch. Round (Single Screen) (Single Screen) (1) A3PT Standard Loads Contact type Output Lighting Standard load (250 VAC, 3 A; 30 VDC, 4 A) Operation Momentary operation (Self-resetting) Alternate operation (Self-holding) Case color Light gray Light gray Pushbutton color symbol SPDT LED lamp 24 VDC A3PT-90A12-24C(1) A3PT-90B12-24C(1) ROGW DPDT LED lamp 24 VDC A3PT-90C12-24C(1) A3PT-90D12-24C(1) ROGW Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PT-90A12-24C R Round (Single Screen) (Single Screen) (1) A3PT Microloads Contact type Output Lighting Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A) Operation Momentary operation (Self-resetting) Case color Light gray Pushbutton color symbol SPDT LED lamp 24 VDC A3PT-90E12-24C(1) ROGW DPDT LED lamp 24 VDC A3PT-90G12-24C(1) GW Note: Enter the desired color symbols for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White. Example: Red A3PT-90E12-24C R Individual models: Refer to pages 7 to 11. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. (The Pushbutton, Lamp, and Switch can be ordered separately.) ■ Accessories: Refer to pages 10 to 11. 5 A3P Ordering Information Illumination-only and Colored-illumination LED Models “Illumination only” describes LED models for which the screen color is the same whether the LED is lit or not. The screen simply becomes brighter when the LED lights. Example: Red LED Not lit Cap (transparent) Red Lit Legend plate (transparent) Red Pushbutton (Display) Colored plate (red) Lamp holder LED lamp (red) - - - Lamp “Colored illumination” describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp when the LED is lit. Example: Red LED Not lit White Cap (transparent) Lit Legend plate (transparent) Red Pushbutton (Display) Colored plate (white) Lamp holder LED lamp (red) - - - Lamp Ordering: With colored-illumination models, order the Pushbutton, Lamp, and Switch as shown in the following table. Pushbutton Lamp Select the LED lamp-lighted model required from the selection on page 8. Each assembly includes the number of white colored plates required to enable colored illumination for the corresponding screen-split configuration. For example, 4-split screen models include 4 white colored plates. Select the LED lamps to suit your desired coloration from the selection on page 9. Number of necessary LED lamps (standard) A3PJ (rectangular): 4 A3PA (square): 2 A3PT (round): 2 Switch Select from the Switches on page 9. 6 A3P Ordering Information Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. LED-lighted (Single screen models only)/ Chameleon Models (LED is built into the Pushbutton.) LED Lamp-lighted Models (LED lamp and Pushbutton are separate.) Pushbutton Pushbutton Round (A3PT) models not available. · For Pushbutton Switch A3P@-502@ · For Pushbutton Switch A3P@-5@@@-@@E Lamp (LED Lamp) *2 SLL-@@E@ Switch *1 Switch *1 Round (A3PT) models not available. · For Pushbutton Switch A3P@-7@@@-@ · For Pushbutton Switch A3P@-7@@@-@ *1. The Switch is compatible with LED-lighted models and LED lamp-lighted models. *2. Number of necessary LED lamps. Screen pattern A3PJ A3PA A3PT Single screen 2 2 Horizontal 2-split screen 2 --- Vertical 2-split screen Vertical 3-split screen Horizontal 3-split screen 4 4-split screen Ordering set combinations: Refer to page 3 to 5. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. ■ Accessories: Refer to pages 10 to 11. 7 A3P Ordering Information Ordering Individually ................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Pushbutton LED-lighted Models (LED is built-in.) Split-screen color (color symbol) Appearance White (W) Red (R) Green (G) Orange (O) Selection precautions A3PJ-5701 -@@E A3PJ-5702 -@@E A3PJ-5703 -@@E A3PJ-5706 -@@E • Enter the voltage to be used in the@@at the end of the model number. Rectangular models Single screen Square models A3PA-5701 -@@E Single screen A3PA-5702 -@@E A3PA-5703 -@@E A3PA-5706 -@@E Examples of voltages used: 5V=@ 0@ 5E 12V=@ 1@ 2E 24V=@ 2@ 4E • For the color of the shaded part, select the model according to the colors given at the top of the table. Note: 1. A cap, legend plate (transparent), colored plate, white plunger case, and LED (with a current-limiting resistor) are built into the standard lighting unit. 2. Split-screen coloring configurations are given with the OMRON mark on the Switch facing down. 3. The LED is built-in and cannot be replaced individually. LED Lamp-lighted Models (LED is not built-in.) Rectangular models Square models Round models Appearance Screen pattern Selection precautions Screen Model Screen Model Screen Model Single screen A3PJ-5021 A3PA-5021 Horizontal 2- split screen A3PJ-5022 A3PA-5022 Vertical 2-split screen A3PJ-5023 --- --- Horizontal 3-split screen A3PJ-5024 --- --- Vertical 3-split screen A3PJ-5025 --- --- 4-split screen A3PJ-5026 --- A3PT-5021 --- --- • Parts included: Colored plates (white, red, green, and orange), a legend plate (transparent), and a light baffle (split-screen models only) are included. Use the appropriate combination for the LED coloring required. • The number of white colored plates required to enable colored illumination for the corresponding screen-split configuration is included. (For example, 4-split screen models include 4 white colored plates). • The number of colored plates included for each model are shown in the following table. Screen pattern Single screen Horizontal 2split screens Vertical 2-split screens Horizontal 3split screens Vertical 3-split screens * 4-split screen White Red Green Orange 1 1 1 1 2 1 1 1 3 2 2 2 4 1 1 1 * The following types of colored plates are included with Horizontal and Vertical 3-splitScreen Switches. White: One colored plate for a 2-split screen and two colored plates for a 4-split screen. Red, green, or orange: One colored plate for a 2-split screen and one colored plates for a 4-split screen. Ordering set combinations: Refer to page 3 to 5. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. ■ Accessories: Refer to pages 10 to 11. 8 A3P Ordering Information Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Pushbutton (For information on mounting of LED lamps, refer to page 23.) Chameleon Models (with Built-in LED) Appearance Chameleon pushbutton switch Rated voltage Rectangular Square 12 VDC A3PJ-5800-12E 24 VDC A3PJ-5800-24E 12 VDC A3PA-5800-12E 24 VDC A3PA-5800-24E Note: 1. With chameleon models the whole screen lights red, green, or orange (i.e., red and green simultaneously). 2. A cap, legend plate (transparent), white colored plate, and LED (with a current-limiting resistor) are built into the Pushbutton. LED Lamp Voltage Color Red Yellow Green White Switch 5 VDC Model (DC only) SLL-05ER SLL-05EY SLL-05EG SLL-05EW 12 VDC Model (DC only) SLL-12ER SLL-12EY SLL-12EG SLL-12EW 24 VDC Model (DC only) SLL-24ER SLL-24EY SLL-24EG SLL-24EW Applicable cap (color) (colored plate) Selection precautions Red Orange Green White In the standard setup, 4 LED lamps are used with A3PJ models and 2 LED lamps are used with A3PA and A3PT models. (LED models) Rectangular models Square models Round models Appearance Selection precautions Contact type Switch Number of outputs Standard load 1c Silver alloy contact 2c 3c Microload 1c Gold alloy contact 2c 3c Operation Model Model Model Momentary operation A3PJ-7010-1 A3PA-7010-1 A3PT-7010-2 Alternate operation A3PJ-7020-1 A3PA-7020-1 A3PT-7020-2 Momentary operation A3PJ-7030-1 A3PA-7030-1 A3PT-7030-2 Alternate operation A3PJ-7040-1 A3PA-7040-1 A3PT-7040-2 Momentary operation A3PJ-7150-1 --- --- Alternate operation A3PJ-7160-1 --- --- Momentary operation A3PJ-7050-1 A3PA-7050-1 A3PT-7050-2 Alternate operation A3PJ-7060-1 A3PA-7060-1 A3PT-7060-2 Momentary operation A3PJ-7070-1 A3PA-7070-1 A3PT-7070-2 Alternate operation A3PJ-7080-1 A3PA-7080-1 A3PT-7080-2 Momentary operation A3PJ-7170-1 --- --- Alternate operation A3PJ-7180-1 --- --- Ordering set combinations: Refer to page 3 to 5. The end digit denotes the color of the flange: -1 denotes a black flange, and -2 denotes a light gray flange. Round switches are available only in light gray, and not in black. Use the Switch in combination with the same shape Lamp (rectangular, square or round). Example: For rectangular Lamp A3PJ-5011, select Switch A3PJ-7@@0-@. On the Switch itself, however, only 3 digits are shown, as follows: A3PJ-7@@. Momentary operation is self-resetting, and alternate operation is self-holding (i.e., push-on, push-off). ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16. ■ Accessories: Refer to pages 10 to 11. 9 A3P Ordering Information Accessories, Replacements, and Tools Accessories Name Socket Appearance Classification Rectangular Square Application precautions Wire-wrap terminal A3PJ-4101 A3PA-4101 PCB terminal A3PJ-4102 A3PA-4102 Solder terminal A3PJ-4103 A3PA-4103 • The Socket cannot be used with when mounting multiple Switches or with 3C models. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. Black A3PJ-4001 A3PA-4001 Light gray A3PJ-4002 A3PA-4002 Black A3PJ-4004 Light gray A3PJ-4005 Black A3PJ-4007 A3PA-4007 Light gray A3PJ-4008 A3PA-4008 Black A3PJ-4010 Light gray A3PJ-4011 Short edge barrier (Horizontal mounting) (1 pair) Long edge barrier (Vertical mounting) (1 pair) --- Barrier Short intermediate barrier (Horizontal mounting) Long intermediate barrier (Vertical mounting) • The purpose of the barrier is to prevent malfunctioning and to improve design image of the mounting panel. • Intermediate barrier × 1. • Edge barriers × 1 pair (2 Units). • Mount short barriers horizontally. • Mount long barriers vertically. • For details on mounting, refer to page 23. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. --- For horizontal mounting (with OMRON logo facing down) A3PJN-5050 A3PAN-5050 For vertical mounting (with OMRON logo facing to the right) A3PJN-5055 A3PAN-5055 Switch guard Seal cover --- A3PJ-5060 A3PA-5060 Long mounting plate --- A3PJ-3002 --- • Can be used by exchanging with the cap. • Cannot be used with seal cover. • Can be used with barrier. • Use horizontal mounting guard for consecutive horizontal mounting, and use vertical mounting guard for consecutive vertical mounting. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. • Cannot be used with barrier and/ or switch guard. • For details on mounting, refer to page 23. • Cap is manufactured from vinyl chloride. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. • Use when vertically mounting individual (with barrier) or multiple Switches (in standard mounting style and with barrier). Since a short mounting plate is attached to the Switch, replace it with the long one. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. 10 A3P Ordering Information Accessories Name Appearances Classification Single screen Horizontal 2split screen A3PA A3PJ-5301 A3PA-5301 Red A3PJ-5302 A3PA-5302 Green A3PJ-5303 A3PA-5303 Yellow A3PJ-5305 A3PA-5305 Orange A3PJ-5306 A3PA-5306 White A3PJ-5321 A3PA-5321 Red A3PJ-5322 A3PA-5322 Green A3PJ-5323 A3PA-5323 Yellow A3PJ-5325 A3PA-5325 Orange A3PJ-5326 A3PA-5326 White A3PJ-5331 --- Red A3PJ-5332 --- Yellow A3PJ-5335 --- Orange A3PJ-5336 --- White A3PJ-5361 --- Red A3PJ-5362 --- Green A3PJ-5363 --- Orange A3PJ-5366 --- Horizontal 2-split screen A3PJ-4302 A3PA-4302 Vertical 2-split screen A3PJ-4303 --- Long axis A3PJ-4304 --- Colored plate for LED Vertical 2-split screen 4-split screen Light baffle A3PJ White Horizontal 3split screen Short axis A3PJ-4305 --- Vertical 3-split screen Long axis A3PJ-4306 --- 4-split screen Long axis A3PJ-4304 --- Transparent legend plate A3PJ-5202 A3PA-5202 Milk-white legend plate A3PJ-5201 A3PA-5201 Transparent cap A3PJ-5600 A3PA-5600 Legend plate Cap Crimp-processed transparent cap Tools Name Extractor Appearance A3PJ-5600-A A3PA-5600-A Classification Model --- A3PJ-5080 Application precautions • Keep mounted at all times. If the colored plate is lost or damaged, contact OMRON. • Use in accordance with coloring of the built-in LED. • For details on mounting, refer to page 23. • You cannot use the same Colored Plates for Incandescent Lamps for the A3P Ultra Bright Lighted Pushbutton Switches. • Keep mounted at all times. If the light baffle is lost, contact OMRON. • Used in LED lamp-lighted models. Cannot be used in LED-lighted models. • You cannot use the same Colored Plates for Incandescent Lamps for the A3P Ultra Bright Lighted Pushbutton Switches. • A transparent legend plate is mounted on the Pushbutton. • You cannot use the same Colored Plates for Incandescent Lamps for the A3P Ultra Bright Lighted Pushbutton Switches. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. • The surface is crimp-processed, so there is no reflection. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. Application precautions • Use to extract components when replacing the Pushbutton. • You can use the same Sockets for the A3P Ultra Bright Lighted Pushbutton Switches. 11 A3P Specifications Approved Standard Ratings Ratings UL (File No. E41515), CSA (File No. LR45258) Contact Ratings Silver Alloy Contacts (for Standard Loads) Standard Load: Microload: 5 A at 125 VAC 3 A at 250 VAC 0.1 A at 125 VAC 0.1 A at 30 VDC Rated voltage (V) Note: 1. Certification has been obtained for the Switch Unit. For detailed information on individual products that have received certification, consult your supplier. 2. Only Switch output 1c and 2c are certified. CCC (GB/T14048.5) Standard Load: Microload: 3 A at 250 VAC 4 A at 30 VDC 0.1 A at 125 VAC 0.1 A at 30 VDC Non-inductive load (A) Resistive load NC NO Inductive load (A) Lamp load NC Inductive load NO NC NO Motor load NC 125 VAC 250 VAC 5 3 0.7 0.5 3 2 1.3 0.8 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC 5 5 4 0.4 0.2 2 2 2 0.05 0.03 4 4 3 0.4 0.2 3 3 3 0.05 0.03 NO Note: 1. The above values are for steady-state currents. 2. Inductive load: Power factor = 0.4; time constant = 7 ms. 3. The lamp load has an inrush current of 10 times the steady-state current. 4. The motor load has an inrush current of 6 times the steady-state current. Standard testing condition (1) Ambient temperature: 20 ± 2°C (2) Ambient humidity: 65 ± 5%RH (3) Operating frequency: 20 times/min. Note: Only Switch output 1c and 2c are certified. Gold Alloy Contacts (for Microloads) 0.1 A at 30 VDC (resistive load); 0.1 A at 125 VAC (resistive load) Rated voltage (V) Minimum applicable load 1 mA at 5 VDC LED Ratings LED for LED-lighted Models Single screen Model Applied voltage Rated voltage LED Lamp (for LED Lamp-lighted Models) A3PJ/M2PJ Current Red, white Approx. 5 VDC±5% 5 VDC 40 mA 12 VAC/VDC 12 VAC/ Approx. VDC 20 mA ±5% 24 VAC/VDC 24 VAC/ Approx. VDC 10 mA ±5% A3PA/M2PA Current Red, white Approx. Approx. Approx. 20 mA 18 mA 20 mA Approx. Approx. Approx. 10 mA 8 mA 10 mA Approx. Approx. Approx. 5 mA 4 mA 10 mA Orange Green Orange Green Approx. Approx. 10 mA 9 mA Approx. Approx. 5 mA 4 mA Approx. Approx. 5 mA 4 mA LED for Chameleon Models Applied voltage Rated voltage 12 VDC±5% 24 VDC±5% 12 VDC 24 VDC Current Green Approx.26 mA Approx.13 mA Red Approx.20 mA Approx.10 mA Type DC only Applied voltage 5 VDC±5% 12 VDC±5% 24 VDC±5% Rated voltage 5 VDC 12 VDC 24 VDC Current Model Approx. 30 mA Approx. 15 mA Approx. 12.5 mA SLL-05E@ SLL-12E@ SLL-24E@ • Mis-lighting of the LED The LED lights with approx. 0.1 mA or less of micro-current. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED. The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current. (Circuit example) In case of using 24 VAC/VDC, Direct lighting X1 LED lamp R:10kΩ (1W) Bleeder resistor X2 12 A3P Characteristics Mechanical Electrical Operating frequency Insulation resistance Standard load Microload Between terminals of same polarity Between terminals of different polarity Between current-carrying metal part and ground Between each terminal and non-current-carrying metal part Between lamp terminals Malfunction Destruction Malfunction Contact resistance Dielectric strength Vibration resistance Shock resistance Mechanical Life expectancy Electrical Weight NC NO Inrush current Ambient operating temperature Ambient operating humidity Ambient storage temperature Degree of protection Electric shock protection class PTI (proof tracking index) Pollution degree 120 operations/minute max. *1 30 operations/minute max. 100 MΩ min. (at 500 VDC) 40 mΩ max. (initial value) 40 mΩ max. (initial value) 1,000 VAC, 50/60 Hz for 1 minute *2 2,000 VAC, 50/60 Hz for 1 minute 2,000 VAC, 50/60 Hz for 1 minute 2,000 VAC, 50/60 Hz for 1 minute 1,000 VAC, 50/60 Hz for 1 minute *3 10 to 55 Hz, 1.5 mm double amplitude (1 ms max.) 500 m/s2 max. 200 m/s2 max. (1 ms max.) Momentary operation models: 1,000,000 operations min. Alternate operation models: 200,000 operations min. (One operation consists of set and reset operations.) 100,000 operations min. Approx. 30 g Silver contact: 10 A max. Silver contact: 10 A max. LED-lighted models: −10°C to 40°C (with no icing or condensation) 35% to 85%RH −25°C to 65°C IP40 Class II 175 3 (IEC947-5-1) *1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations. *2. 600 VAC for microloads. *3. With no LED lamp mounted. Operating Characteristics A3PJ series Model Operating Characteristics Momentary operation models A3PA series Alternate operation models Momentary operation models A3PT series Alternate operation models Momentary operation models Alternate operation models Operating force OF max. 5.88 N 6.86 N 5.88 N 6.86 N 3.92 N Releasing force RF min. 0.39 N 0.29 N 0.39 N 0.29 N 0.39 N 4.90 N 0.29 N Total travel TT Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Pretravel PT max. 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm Lock travel alternate LTA min. --- 0.5 mm --- 0.5 mm --- 0.5 mm 13 A3P Nomenclature Model Structure Lighting method Models Screen patterns LED-lighted models (LED is built-in.) A3PJ A3PA Single screen Single screen Chameleon (3-color) Chameleon (3-color) A3PJ Single screen A3PT Single screen Single screen Vertical 3-split screen Horizontal 2-split Horizontal 3-split screen screen Vertical 2-split screen LED-lighted models LED-lighted models LED lamp-lighted models (LED lamp is not built-in.) A3PA Horizontal 2-split screen 4-split screen LED lamp-lighted models Chameleon models (full screen illumination in one of three colors) Cap (transparent) Legend plate (transparent) Legend plate (transparent) Colored plate Colored plate LED Unit LED Unit 3-color emitter Built-in LED Cap (transparent) Cap (transparent) Pushbutton Legend plate (Split-screen models (transparent) contain a light baffle.) ●Pushbutton colors Colored plate · LED-lighted models and LED lamp-lighted models Lamp holder ●Switch Specifications Standard load · 250 VAC, 3 A 30 VDC, 4A Microload · 125 VAC, 0.1 A 30 VDC, 0.1 A Minimum applicable load: 5 VDC, 1 mA White, Red, Green, Orange Lamp ●Case Color Select either black or light gray to suit your panel design. (The round A3PT models are available in light gray only.) Switch 14 A3P Nomenclature A3P Lighting Method Diagram The following diagram shows the Switches with the LED-lighted models mark facing down. Single screen models • As a set: See page 3. • Individually: See page 7. Single screen Horizontal 2-split Vertical 2-split models screen models screen models A3PJ (rectangular) LED models LED lamp-lighted models Chameleon models Vertical 3-split Horizontal 3-split 4-split screen screen models screen models Single screen models • Individually: See page 7. (Not available as a set.) • As a set: See page 3. • Individually: See page 7. (Full screen illumination in one of three colors) LED-lighted models A3PA (square) LED models LED lamp-lighted models Chameleon models A3PT (round) LED models LED lamp-lighted models Single screen models Single screen Horizontal 2-split screen models models Single screen models Single screen models • As a set: See page 4. • Individually: See page 7. • Individually: See page 7. (Not available as a set.) • As a set: See page 4. • Individually: See page 7. • As a set: See page 5. • Individually: See page 7. 15 A3P Dimensions (Unit: mm) The Dimension shows switch output 2c. A3PJ (Rectangular) Models A3PA (Square) Models 2.8 26.1 22 29.9±0.2 0.5 OMRON logo OMRON logo 25±0.1 #110 quick connect terminal/ solder terminal 22.9±0.2 18.9 6.7 32±0.1 43.6 Separator 19.1 × 19.1 25±0.1 25±0.1 #110 quick connect terminal/ solder terminal 22.9±0.2 6.7 43.6 52 max. 52 max. 52.6 52.6 Separator A3PT (Round) Models #110 quick connect terminal/solder terminal 22.4 28.5 dia. OMRON logo 24.9 dia. 32 dia. 23.8 6.4 43.6 52 max. 52.6 Note: The thickness of tab terminals #110 and solder terminals is 0.5 mm. 16 A3P Dimensions (Unit: mm) Terminal connections LED-lighted Models (The terminal arrangement diagram shows switch output 1c. Connections to terminals from the lighting block are the same for switch output 2c.) Rated voltage Screen Model pattern 5 VDC 12 VAC/VDC Bottom view Top view Bottom view Terminal arrangement Lighting block Terminal arrangement Top view 24 VAC/VDC Bottom view Top view Terminal arrangement Lighting block Single screen A3PJ Bottom view Top view Lighting block Bottom view Top view Single screen A3PA Terminal Lighting block arrangement Terminal Lighting block arrangement 17 A3P Dimensions (Unit: mm) LED Lamp-lighted Models (All are shown with the OMRON logo facing down.) Model Rectangular A3PJ models Output Bottom view Top view Square A3PA models Bottom view Bottom view Top view NO1 NO1 NO1 LC+ LC+ NC1 SPDT Top view Round A3PT models NC1 LC+ C1 NC1 C1 Terminal arrangement C1 Lighting block Terminal arrangement Lighting block Top view Bottom view Top view Bottom view Lighting block Terminal arrangement Bottom view Top view NO1 NO2 NO1 NO2 PPDT LC+ NC1 NC2 C1 C2 LC+ NO1 NO2 LC+ NC1 NC2 C1 C2 NC1 C1 Terminal arrangement Lighting block Bottom view Top view Terminal arrangement Lighting block NC2 C2 Terminal arrangement Lighting block NO1 NO2 NO3 3PDT NC1 NC2 NC3 C1 C2 C3 --- LC+ Terminal arrangement --- Lighting block LED Chameleon Models (The terminal arrangement diagram shows switch output 1c. Connections to terminals from the lighting block are the same for switch output 2c.) Rated voltage Model 24 VDC Rectangular A3PJ model NO1 Square A3PA model L2− NC1 L4− C1 L3− L1− LC+ NO1 L1− LC+ NC1 L2− C1 Terminal Arrangement and Coloring Chameleon Models Wiring Coloring LC+ LC+ L1− L2− Green Red LC+ L1− and L2− shorted Orange 18 A3P Dimensions (Unit: mm) Panel Cutout (If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 21.) A3PJ (Rectangular) Models Classification Individual mounting (Horizontal) Multiple mounting (Horizontal) Flange mount models Individual mounting (Vertical) Multiple mounting (Vertical) Barrier mount models Mounting design 23.5±0.3 32±0.1 25±0.1 1 32n−1.5 ±0.3 n 2 Mount to long mounting plate (A3PJ-3002) before use. 32±0.1 25±0.1 1 2 Mount to long mounting plate (A3PJ-3002) before use. n 25n±0.5 Individual mounting (Horizontal) 27 Multiple mounting (Horizontal) 27 1 6 min. 30.5±0.3 25n−1.5 ±0.3 30.5±0.3 1 32.9n+3.5±0.3 n 2 23.5±0.3 Mount to long mounting plate (A3PJ-3002) before use. 34 34 23.5±0.3 23.5±0.3 33n+6±1 Multiple mounting (Vertical) 3 min. 36.4±0.3 39 Individual mounting (Horizontal) Panel cutout spacing between rows of Units: 23.5±0.3 32n±0.5 32±0.1 Remarks 30.5±0.3 25±0.1 32±0.1 Note: 1. 2. 3. 4. Panel cutout 2 n 26n+6±1 Mount to long mounting plate (A3PJ-3002) before use. For barrier mount models, refer to Accessories on page 10. Panel cutout spacing between rows of Units: (Dotted line indicates the position of each mounting barrier.) 29.4±0.3 1.3 30.5±0.3 6 min. 6 min. 25.9n+3.5±0.3 30.5±0.3 n: Number of Units Recommended panel thickness: 1 to 5 mm Mount the panel before mounting the Switch Guard. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. A3PA (Square) Models Classification Individual mounting Flange mount models Mounting design Panel cutout 6 min. 25±0.1 1 23.5±0.3 n 2 25n−2.5 ±0.3 25n±0.1 Individual mounting Barrier mount models 27 27.8±0.3 1 2 26n+6.5±1 Note: 1. 2. 3. 4. Panel cutout spacing between rows of Units: (Dotted line indicates the position of each mounting barrier.) 23.5±0.3 27 32 Multiple mounting 3 min. 22.5±0.3 25±0.1 Multiple mounting Panel cutout spacing between rows of Units: 23.5±0.3 25±0.1 Remarks n 1.3 6 min. 6 min. 23.5±0.3 26n+2.5±0.3 n: Number of Units Recommended panel thickness: 1 to 5 mm Mount the panel before mounting the Switch Guard. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. A3PT (Round) Models 6.4 dia. +0.2 11.8R −0 29±0.3 dia. 4 min. Note: 1. Recommended panel thickness: 1 to 5 mm 2. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. 19 A3P Dimensions (Unit: mm) Accessory Mounting Dimensions Legend Plate Rectangular Models A3PJ-5201/-5202 Extractor A3PJ-5080 Square Models A3PA-5201/-5202 25.1 20 2.5 2.5 17.2 15 16.9 17.2 50 Plate surface 1.2 10 5 0.3 1.5 25±2 Note: Made from stainless steel. 1.5 24 Socket-mounting Dimensions Rectangular Models A3PJ (M2PJ) Square Models A3PA (M2PA) Wire-wrap Terminal A3PJ-4101 Wire-wrap Terminal A3PA-4101 25.6 18 25.6 18 24 31.8 1 × 1 Wire-wrap Terminal 1 × 1 Wire-wrap Terminal 22.8 22.8 61.6 61.6 25.6 PCB Terminal A3PJ-4102 18.5±0.8 PCB Terminal A3PA-4102 18 18.5±0.8 25.6 18 3 1.2 3 1.2 24 31.8 0.3 0.3 22.8 22.8 61.6 61.6 0.5 3.6 PCB Cutout (bottom view) 3.6 PCB Cutout (bottom view) 0.5 1.5 17.4 8.7 5.2 2.05 10.4 17.6 10.5 8.65 1.25 3.5 7 6.15 8.8 5.25 8.4 Eleven, 1.5-dia. holes Nine, 1.5-dia. holes 10.2 20.45 7 11.65 Solder Terminal A3PJ-4103 25.6 Solder Terminal A3PA-4103 25.6 18 3 31.8 18 3 Terminal Hole Dimensions Terminal Hole Dimensions 0.8 0.8 0.3 24 0.3 3.2 3.2 3 3 0.9R 22.8 22.8 0.6R 61.6 61.6 8.2 0.9R 0.6R 8.2 Note: PCB cutout dimensions show the switch mounted to the socket with the OMRON logo facing down. 20 A3P Dimensions (Unit: mm) Switch and Guard Mounting Dimensions Rectangular Models A3PJN-5050 (Horizontal Mounting) A3PJN-5055 (Vertical Mounting) Spring 25±0.1 52.6 52 max. 43.6 9.6 Square Models A3PAN-5050 (Horizontal Mounting) A3PAN-5055 (Vertical Mounting) Spring 25±0.1 25.2 Switch Guard (A3PJN-5050) 52.6 52 max. 43.6 9.6 25.4 25±0.1 32±0.1 Guard Switch Guard (A3AN-5050) OMRON logo OMRON logo 19.1 26.2±0.2 Panel Cutouts Individual Mounting (Horizontal) Panel Cutouts Individual Mounting (Horizontal) Multiple Mounting (Horizontal) Multiple Mounting (Horizontal) 22.5±0.3 25n-2.5 ±0.3 32n-1.5 ±0.3 30.5±0.3 23.5±0.3 23.5±0.3 23.5±0.3 23.5±0.3 n = Number of mountings n = Number of mountings Note: Multiple vertical mounting is not possible. Note: Multiple vertical mounting is not possible. Seal Cover Mounting Dimensions Rectangular Models A3PJ-5060 Cover A (transparent) Cover B (black) Seal Cover (A3PJ-5060) Square Models A3PA-5060 Cover A (transparent) Cover B (black) OMRON logo 32.5 Seal cover (A3PA-5060) OMRON logo 32.5 39.5 9.3 42.9 32.5 8.7 51.3 max. 51.9 Multiple Mounting (Horizontal) Panel Cutouts Individual Mounting (Horizontal) 42.9 51.3 max. 51.9 Panel Cutouts Individual Mounting Multiple Mounting 9.5 min. 22.5±0.3 10.5 min. 30.5±0.3 22.5±0.3 30.5±0.3 23.5±0.3 23.5±0.3 9.5 min. 23.5±0.3 23.5±0.3 9.5 min. Note: 1. Recommended panel thickness: 1 to 5 mm 2. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions. 21 A3P Safety Precautions Refer to Safety Precautions for all Pushbutton Switches/Indicators. Caution Precautions for Correct Use 1. Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or fire may occur. 2. After wiring the Switch, make sure that there is a suitable isolation distance. Wiring • Solder quickly and correctly at 350°C max and for 3 s or less. Wait for one minute after soldering before exerting any external force on the solder. Operating Environment • Do not use in locations that are subject to dust, oil, or metal filings as these may penetrate the interior of the Switch and cause malfunction. Using Microloads • Using a standard load switch when a microload circuit is opened or closed may cause contact failure on the contacts. Use the switch within the operating range. (Refer to the diagram below.) Even when using microload models within the operating range shown below, if inrush current occurs when the contact is opened or closed, it may cause the contact surface to become rough, and so decrease life expectancy. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the Nlevel reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation, λ 60 = 0.5 x 10−6/time indicates that the estimated malfunction rate is less than 1/2,000,000 with a reliability level of 60%. Voltage (V) Do not apply a voltage higher than the maximum rated operating voltage between the lamp terminals, as there is a risk that LED will be damaged, and the Pushbutton will be ejected. 30 26 mA 100 mA 0.15 mA 24 LED (for VDC) • Check the terminal polarity when wiring. • The rated voltage is shown on the plate on the back of the lighting unit, so be sure to use within the voltage shown. • An LED current-limiting resistor is built in, so there is no need to mount an external resistor. Character Plate (Character Film) • If preparing the character plate separately, use a heat-resistant film with a thickness of 0.1 to 0.3 mm. 24.1 +0 −0.1 12 Invalid area 5 1 mA 100 mA 160 mA 0 0.1 1 10 100 1,000 Current (mA) Others 17.1 +0 −0.3 17.1 +0 −0.3 Standard load area Microload area 17.1 +0 −0.3 • If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. 24.8 +0 dia. −0.3 23.±0.1 dia. 5.2+0 −0.3 22 A3P Assembly/Disassembly A3PJ/M2PJ (Rectangular Models), A3PA/M2PA (Square Models) Locking/Unlocking Positive Cap Lock Mechanism Lock Unlock Positive cap stopper Mounting Pushbutton • Be sure to mount the Pushbutton with the correct orientation. Align the groove on the Pushbutton, the projections in the Switch, and the LED contact piece before pushing the Pushbutton into the Switch. • When dismounting the Pushbutton, use the Extractor (A3PJ-5080) for easy dismounting. OMRON logo Groove Mounting and Replacing LED Lamps If using a square model with one LED lamp, insert the lamp in the center hole. Note: Built-in LEDs cannot be replaced. LED Rated Voltage Display (LED Models Only) The LED rated voltage is shown between the built-in resistors on the back of the lighting unit. Use within a range of ± 5%. A3PJ Rated voltage display A3PA LED contact piece Diagram shows A3PA model. Removing/Mounting Cap Insert the A3PA from the open side into the theft-prevention stopper. Note: Display is on the back. Mounting Switch onto Panel Mounting Colored Plate Place the colored plate on the plunger case with the dull side of the colored plate facing downward. With A3PJ split-screen models, be sure that the projections on the upper surface of the colored plate face outward. For the A3PA, make sure that the flat plate is facing upwards. • Individual Mounting and Barrier Mounting When mounting the Switch, push it into the panel cutout from the front of the mounting panel by holding it with the logo mark “OMRON” facing downward. • Multiple Barrier Mounting (A3PJ) When mounting a number of Switches in line on the panel, link the Switches with spacing barriers in between, attach mounting barriers at both sides of this block of Switches and, pushing in on the mounting barriers at the side, insert the Switches into the panel cutout together. Flat plate Projection OMRON logo OMRON logo A3PA A3PJ Mounting Barriers Mount each part by pushing it in the direction of the arrow shown in the corresponding illustration below. Mounting Character Plate (Character Frame) and Legend Plate Mount the legend plate for the A3PJ under the layered surfaces and mount the cap, as shown below. Barrier mounting Transparent cap Legend plate (Character plate) Colored plate (Light baffle) 23 A3P Mounting Seal Cover After mounting the seal cover onto the flange of the Switch, push the Switch into the panel cutout. Inscribing the Legend Plate • Inscribe the legend plate to a depth of 0.5 mm max. • The legend plate is made from polycarbonate resin. To coat the legend plate, use an alcohol-based coating such as melamine, phthalic acid, or acrylic. Maintenance Lock 1. First, when you insert the transparent lens while pressing the center, the maintenance lock mechanism will be activated, and the Switch will not operate. Lamp replacement and other maintenance can be performed without turning OFF the power supply to devices and equipment. Use an insertion force of 4 kg. 2. Next, when you remove your finger from the Switch, the lock will be released. 3. The Switch will start to operate when the lighting unit is pressed the second time. 24 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2022.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2022 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: A3PJ-5080 A3PA-4001 A3PA-4101 A3PA-4102 A3PA-4103 A3PA-5011 A3PA-5012 A3PA-5050 A3PA-5060 A3PA-5101 A3PA-5106 A3PA-5121 A3PA-5201 A3PA-5202 A3PA-5600 A3PA-5701-06E A3PA-5701-12E A3PA5701-24E A3PA-5702-05E A3PA-5702-12E A3PA-5702-24E A3PA-5703-05E A3PA-5703-24E A3PA-5706-05E A3PA-5706-12E A3PA-5706-24E A3PA-5711-24E A3PA-5712-O5E A3PA-5713-24E A3PA-5716-24E A3PA-572324E A3PA-5731-24E A3PA-5732-24E A3PA-5733-24E A3PA-5736-05E A3PA-5736-12E A3PA-5742-24E A3PA5746-24E A3PA-5803-24E A3PA-7010-1 A3PA-7020-1 A3PA-7030-1 A3PA-7040-1 A3PA-7050-1 A3PA-7070-1 A3PA-90A11-24EG A3PA-90A11-24EO A3PA-90A11-24ER A3PA-90A11-24EW A3PA-90A11-28 A3PA-90C12-28 A3PA-90D11-06 A3PJ-3002 A3PJ-4001 A3PJ-4002 A3PJ-4004 A3PJ-4007 A3PJ-4010 A3PJ-4102 A3PJ-4103 A3PJ-4302 A3PJ-4305 A3PJ-4308 A3PJ-4501 A3PJ-5011 A3PJ-5012 A3PJ-5014 A3PJ-5016 A3PJ-5021 A3PJ5022 A3PJ-5023 A3PJ-5050 A3PJ-5055 A3PJ-5060 A3PJ-5101 A3PJ-5103 A3PJ-5122 A3PJ-5124 A3PJ-5125 A3PJ-5161 A3PJ-5162 A3PJ-5165 A3PJ-5166 A3PJ-5201 A3PJ-5202 A3PJ-5207 A3PJ-5502 A3PJ-5600 A3PJ5701-05E A3PJ-5701-12E A3PJ-5701-24E A3PJ-5702-06E A3PJ-5702-12E A3PJ-5702-24E A3PJ-5703-24E A3PJ-5706-24E A3PJ-5711-24E A3PJ-5712-12E A3PJ-5712-24E A3PJ-5713-12E
A3PJ-5712-12E 价格&库存

很抱歉,暂时无法提供与“A3PJ-5712-12E”相匹配的价格&库存,您可以联系我们找货

免费人工找货