Lighted Pushbutton Switch (Square)
A3P
CSM_A3P_DS_E_8_3
Large Square-bodied Lighted
Pushbutton Switches
• Excellent operating sensitivity.
• Excellent illumination with even surface brightness.
• Three-color models (green, orange, red; chameleon lighting)
included in lineup.
Refer to Safety Precautions for All Pushbutton Switches/
Indicators and Safety Precautions on page 22.
List of Models
Model
Appearance
52 max.
6.7
A3PJ
(Rectangular)
25
32
52 max.
6.7
A3PA
(Square)
25
25
6.4
52 max.
A3PT
(Round)
32 dia.
Note: The A3PJ is shown in the figure above as an example.
■ Specifications: Refer to page 12. ■ Panel cutout: Refer to page 19. ■ Dimensions: Refer to page 16.
■ Accessories, replacements, and tools: Refer to pages 10 to 11. ■ Precautions for correct use: Refer to page 22.
1
A3P
Model Number Structure
Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton,
Lamp, and Switch.
For more information, refer to Ordering Information (pages 3 to 5).
Some forms may not be available for order depending on the combination of functions and specifications
described below. Contact your OMRON sales representative for more detailed information.
(1)
(2) (3) (4)
(5)
A 3 P J - 90 B 1 1 -
(1) Shape of
Pushbutton
Symbol
Shape
Rectangular
Square
Round
(2) Switch
Specifications
Standard Load
24E R
................... Single screen
(3) Screen Pattern
Illumination-only models
Symbol
Screen pattern
Symbol
Operation
Momentary
A
SPDT
A
B
Alternate
T
C
Momentary
DPDT
Momentary operaD
Alternate
tion: Self-resetting
Alternate opera- Microload
tion: Self-holding
Symbol
Operation
Momentary
E
SPDT
F
Alternate
Momentary
G
DPDT
H
Alternate
J
(6) Upper Lower
• Standard Load
250 VAC, 3 A
30 VDC, 3 A
• Microload
125 VAC, 0.1 A
30 VDC, 0.1 A
Single screen
1
gray
Chameleon *1
G
Note: 1. The chameleon screen pattern
is not available with A3PT models.
2. The chameleon screen pattern
is only available with 12 or 24-VDC
models.
*1. With chameleon models, the whole
screen lights red, green, or orange.
When not lit, the display is white.
Note: The available rectangular and
square models are shown below.
Select from among the individual
products shown on page 8.
(The square models are only
available with horizontal 2-split
screen models)
Minimum applicable load
5 VDC, 1 mA
Horizontal 2-split Vertical 2-split 4-split screen
screen models screen models
models
• 3PDT models are also
available.
Select from among the
individual products shown on
page 9.
(4) Case Color (5) Lighting
(6) Color of Pushbutton
Method
For LED
SymColor
bol
LED-lighted Models Symbol Color
1
Black
(A3PJ and A3PA
R
Red
Light
Models Only)
O
orange
2
Horizontal 3-split Vertical 3-split
screen models screen models
Note: A3PT
models are
available in
light gray
only.
Symbol
05E
12E
24E
Rated
voltage
5 VDC
12 VAC/VDC
24 VAC/VDC
LED Lamplighted Models
(A3PT Only)
Symbol
05C
12C
24C
G
W
K
green
white
Chameleon
• The chameleon
screen pattern is not
available with A3PT
models.
• The chameleon
screen pattern is only
available with 12 or
24-VDC models.
Rated
voltage
5 VDC
12 VDC
24 VDC
• A3PJ and A3PA
can also be
ordered
separately. Refer
to page 8 for
details.
The above diagrams show the Switches with
the "
" mark facing down.
Colored-illumination models up
to the 4-split screen models are
available as individual Units.
Refer to page 6.
“Colored-illumination” models
operate in the way shown below:
Unlit
Lit
White
Color
The built-in LED is colored.
Number of LED Lamps
Screen pattern
Single screen
A3PJ
A3PA
Models with built-in LED
Horizontal 2-split screen
A3PT
2
2 *2
Vertical 2-split screen
Horizontal 3-split screen
Vertical 3-split screen
4 *2
---
---
4-split screen
*2. These split screen models are available only as individual Units.
They cannot be ordered as sets.
2
A3P
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
Rectangular
Models
(Single Screen)
(Single Screen)
(1)
A3PJ
Standard Loads
Contact type
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Operation
Output
Lighting
LED
SPDT
Chameleon
LED
DPDT
Chameleon
Momentary operation (Self-resetting)
Case color
Alternate operation (Self-holding)
Black
Light gray
Black
Light gray
5 VDC
A3PJ-90A11-05E(1)
A3PJ-90A12-05E(1)
A3PJ-90B11-05E(1)
A3PJ-90B12-05E(1)
12 VAC/VDC
A3PJ-90A11-12E(1)
A3PJ-90A12-12E(1)
A3PJ-90B11-12E(1)
A3PJ-90B12-12E(1)
24 VAC/VDC
A3PJ-90A11-24E(1)
A3PJ-90A12-24E(1)
A3PJ-90B11-24E(1)
A3PJ-90B12-24E(1)
12 VDC
A3PJ-90AG1-12EK
---
A3PJ-90BG1-12EK
A3PJ-90BG2-12EK
24 VDC
A3PJ-90AG1-24EK
A3PJ-90AG2-24EK
A3PJ-90BG1-24EK
A3PJ-90BG2-24EK
5 VDC
A3PJ-90C11-05E(1)
A3PJ-90C12-05E(1)
A3PJ-90D11-05E(1)
A3PJ-90D12-05E(1)
12 VAC/VDC
A3PJ-90C11-12E(1)
A3PJ-90C12-12E(1)
A3PJ-90D11-12E(1)
A3PJ-90D12-12E(1)
A3PJ-90D12-24E(1)
24 VAC/VDC
A3PJ-90C11-24E(1)
A3PJ-90C12-24E(1)
A3PJ-90D11-24E(1)
12 VDC
A3PJ-90CG1-12EK
A3PJ-90CG2-12EK
A3PJ-90DG1-12EK
---
24 VDC
A3PJ-90CG1-24EK
A3PJ-90CG2-24EK
A3PJ-90DG1-24EK
A3PJ-90DG2-24EK
Pushbutton
color
symbol
R
O
G
W
*
R
O
G
W
*
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90A11-24E R
* You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details.
Microloads
Contact type
Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Output
Lighting
LED
SPDT
Chameleon
LED
DPDT
Chameleon
Momentary operation (Self-resetting)
Case color
Pushbutton
color symbol
Black
Light gray
5 VDC
A3PJ-90E11-05E(1)
A3PJ-90E12-05E(1)
12 VAC/VDC
A3PJ-90E11-12E(1)
A3PJ-90E12-12E(1)
24 VAC/VDC
A3PJ-90E11-24E(1)
A3PJ-90E12-24E(1)
12 VDC
A3PJ-90EG1-12EK
24 VDC
A3PJ-90EG1-24EK
5 VDC
A3PJ-90G11-05E(1)
---
12 VAC/VDC
A3PJ-90G11-12E(1)
A3PJ-90G12-12E(1)
24 VAC/VDC
A3PJ-90G11-24E(1)
A3PJ-90G12-24E(1)
R
O
G
W
12 VDC
A3PJ-90GG1-12EK
24 VDC
A3PJ-90GG1-24EK
---
*
--A3PJ-90EG2-24EK
R
O
G
W
*
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90E11-24E R
* You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details.
Individual models: Refer to pages 7 to 11.
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 10 to 11.
3
A3P
Ordering Information
Ordering as a Set ..................................The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
Square
Models
(Single Screen)
(Single Screen)
(1)
A3PA
Standard Loads
Contact type
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Operation
Output
Lighting
LED
SPDT
Chameleon
LED
DPDT
Chameleon
Momentary operation (Self-resetting)
Case color
Black
Alternate operation (Self-holding)
Light gray
Black
Light gray
5 VDC
A3PA-90A11-05E(1)
A3PA-90A12-05E(1)
A3PA-90B11-05E(1)
A3PA-90B12-05E(1)
12 VAC/VDC
A3PA-90A11-12E(1)
A3PA-90A12-12E(1)
A3PA-90B11-12E(1)
A3PA-90B12-12E(1)
24 VAC/VDC
A3PA-90A11-24E(1)
A3PA-90A12-24E(1)
A3PA-90B11-24E(1)
A3PA-90B12-24E(1)
12 VDC
A3PA-90AG1-12EK
A3PA-90AG2-12EK
A3PA-90BG1-12EK
A3PA-90BG2-12EK
24 VDC
A3PA-90AG1-24EK
A3PA-90AG2-24EK
A3PA-90BG1-24EK
A3PA-90BG2-24EK
5 VDC
A3PA-90C11-05E(1)
A3PA-90C12-05E(1)
A3PA-90D11-05E(1)
A3PA-90D12-05E(1)
12 VAC/VDC
A3PA-90C11-12E(1)
A3PA-90C12-12E(1)
A3PA-90D11-12E(1)
A3PA-90D12-12E(1)
24 VAC/VDC
A3PA-90C11-24E(1)
A3PA-90C12-24E(1)
A3PA-90D11-24E(1)
A3PA-90D12-24E(1)
12 VDC
A3PA-90CG1-12EK
A3PA-90CG2-12EK
A3PA-90DG1-12EK
A3PA-90DG2-12EK
24 VDC
A3PA-90CG1-24EK
A3PA-90CG2-24EK
A3PA-90DG1-24EK
A3PA-90DG2-24EK
Pushbutton
color symbol
R
O
G
W
*
R
O
G
W
*
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90A11-24E R
* You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details.
Microloads
Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Output
Lighting
LED
SPDT
Chameleon
Momentary operation (Self-resetting)
Case color
Black
5 VDC
A3PA-90E11-05E(1)
A3PA-90E12-05E(1)
12 VAC/VDC
A3PA-90E11-12E(1)
A3PA-90E12-12E(1)
24 VAC/VDC
A3PA-90E11-24E(1)
A3PA-90E12-24E(1)
12 VDC
A3PA-90EG1-12EK
---
24 VDC
A3PA-90EG1-24EK
A3PA-90EG2-24EK
5 VDC
LED
DPDT
Chameleon
Light gray
---
---
12 VAC/VDC
A3PA-90G11-12E(1)
A3PA-90G12-12E(1)
24 VAC/VDC
A3PA-90G11-24E(1)
A3PA-90G12-24E(1)
12 VDC
A3PA-90GG1-12EK
24 VDC
A3PA-90GG1-24EK
---
Pushbutton
color symbol
R
O
G
W
*
R
O
G
W
*
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90E11-24E R
* You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 18 for details.
Individual models: Refer to pages 7 to 11.
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 10 to 11.
4
A3P
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
Round
(Single Screen)
(Single Screen)
(1)
A3PT
Standard Loads
Contact type
Output
Lighting
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Operation
Momentary operation
(Self-resetting)
Alternate operation
(Self-holding)
Case color
Light gray
Light gray
Pushbutton
color symbol
SPDT LED lamp
24 VDC
A3PT-90A12-24C(1)
A3PT-90B12-24C(1)
ROGW
DPDT LED lamp
24 VDC
A3PT-90C12-24C(1)
A3PT-90D12-24C(1)
ROGW
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PT-90A12-24C R
Round
(Single Screen)
(Single Screen)
(1)
A3PT
Microloads
Contact type
Output
Lighting
Microload
(125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Momentary operation
(Self-resetting)
Case color
Light gray
Pushbutton
color symbol
SPDT LED lamp
24 VDC
A3PT-90E12-24C(1)
ROGW
DPDT LED lamp
24 VDC
A3PT-90G12-24C(1)
GW
Note: Enter the desired color symbols for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PT-90E12-24C R
Individual models: Refer to pages 7 to 11.
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 10 to 11.
5
A3P
Ordering Information
Illumination-only and Colored-illumination LED Models
“Illumination only” describes LED models for which the screen color is the same whether the LED is lit or not. The screen simply becomes brighter
when the LED lights.
Example: Red LED
Not lit
Cap (transparent)
Red
Lit
Legend plate (transparent)
Red
Pushbutton
(Display)
Colored plate (red)
Lamp
holder
LED lamp (red) - - - Lamp
“Colored illumination” describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp
when the LED is lit.
Example: Red LED
Not lit
White
Cap (transparent)
Lit
Legend plate (transparent)
Red
Pushbutton
(Display)
Colored plate (white)
Lamp
holder
LED lamp (red) - - - Lamp
Ordering: With colored-illumination models, order the Pushbutton, Lamp, and Switch as shown in the following table.
Pushbutton
Lamp
Select the LED lamp-lighted model required
from the selection on page 8. Each assembly
includes the number of white colored plates required to enable colored illumination for the
corresponding screen-split configuration. For
example, 4-split screen models include 4 white
colored plates.
Select the LED lamps to suit your desired coloration from the selection on page 9. Number
of necessary LED lamps (standard)
A3PJ (rectangular): 4
A3PA (square): 2
A3PT (round): 2
Switch
Select from the Switches on page 9.
6
A3P
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
LED-lighted (Single screen models only)/
Chameleon Models
(LED is built into the Pushbutton.)
LED Lamp-lighted Models
(LED lamp and Pushbutton are separate.)
Pushbutton
Pushbutton
Round (A3PT) models not available.
· For Pushbutton Switch
A3P@-502@
· For Pushbutton Switch
A3P@-5@@@-@@E
Lamp (LED Lamp) *2
SLL-@@E@
Switch *1
Switch *1
Round (A3PT) models not available.
· For Pushbutton Switch
A3P@-7@@@-@
· For Pushbutton Switch
A3P@-7@@@-@
*1. The Switch is compatible with LED-lighted models and LED lamp-lighted models.
*2. Number of necessary LED lamps.
Screen pattern
A3PJ
A3PA
A3PT
Single screen
2
2
Horizontal 2-split screen
2
---
Vertical 2-split screen
Vertical 3-split screen
Horizontal 3-split screen
4
4-split screen
Ordering set combinations: Refer to page 3 to 5.
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
■ Accessories: Refer to pages 10 to 11.
7
A3P
Ordering Information
Ordering Individually ................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbutton
LED-lighted Models (LED is built-in.)
Split-screen color
(color symbol)
Appearance
White (W)
Red (R)
Green (G)
Orange (O)
Selection precautions
A3PJ-5701
-@@E
A3PJ-5702
-@@E
A3PJ-5703
-@@E
A3PJ-5706
-@@E
• Enter the voltage to be
used in the@@at the end of
the model number.
Rectangular
models
Single screen
Square models
A3PA-5701
-@@E
Single screen
A3PA-5702
-@@E
A3PA-5703
-@@E
A3PA-5706
-@@E
Examples of voltages used:
5V=@
0@
5E
12V=@
1@
2E
24V=@
2@
4E
• For the color of the shaded
part, select the model according to the colors given
at the top of the table.
Note: 1. A cap, legend plate (transparent), colored plate, white plunger case, and LED (with a current-limiting resistor) are built into the standard lighting unit.
2. Split-screen coloring configurations are given with the OMRON mark on the Switch facing down.
3. The LED is built-in and cannot be replaced individually.
LED Lamp-lighted Models (LED is not built-in.)
Rectangular models
Square models
Round models
Appearance
Screen pattern
Selection precautions
Screen
Model
Screen
Model
Screen
Model
Single screen
A3PJ-5021
A3PA-5021
Horizontal
2- split screen
A3PJ-5022
A3PA-5022
Vertical 2-split
screen
A3PJ-5023
---
---
Horizontal 3-split
screen
A3PJ-5024
---
---
Vertical 3-split
screen
A3PJ-5025
---
---
4-split screen
A3PJ-5026
---
A3PT-5021
---
---
• Parts included:
Colored plates (white, red, green, and orange), a legend plate (transparent), and a
light baffle (split-screen models only) are included. Use the appropriate combination for
the LED coloring required.
• The number of white colored plates required
to enable colored illumination for the corresponding screen-split configuration is included. (For example, 4-split screen models
include 4 white colored plates).
• The number of colored plates included for each
model are shown in the following table.
Screen pattern
Single screen
Horizontal 2split screens
Vertical 2-split
screens
Horizontal 3split screens
Vertical 3-split
screens *
4-split screen
White
Red
Green
Orange
1
1
1
1
2
1
1
1
3
2
2
2
4
1
1
1
* The following types of colored plates are included with Horizontal and Vertical 3-splitScreen Switches.
White: One colored plate for a 2-split screen and two colored plates for a 4-split screen.
Red, green, or orange: One colored plate for a 2-split screen and one colored plates for a 4-split screen.
Ordering set combinations: Refer to page 3 to 5.
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
■ Accessories: Refer to pages 10 to 11.
8
A3P
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbutton
(For information on mounting of LED lamps, refer to page 23.)
Chameleon Models (with Built-in LED)
Appearance
Chameleon pushbutton
switch
Rated voltage
Rectangular
Square
12 VDC
A3PJ-5800-12E
24 VDC
A3PJ-5800-24E
12 VDC
A3PA-5800-12E
24 VDC
A3PA-5800-24E
Note: 1. With chameleon models the whole screen lights red, green, or orange
(i.e., red and green simultaneously).
2. A cap, legend plate (transparent), white colored plate, and LED (with a
current-limiting resistor) are built into the Pushbutton.
LED Lamp
Voltage
Color
Red
Yellow
Green
White
Switch
5 VDC
Model (DC only)
SLL-05ER
SLL-05EY
SLL-05EG
SLL-05EW
12 VDC
Model (DC only)
SLL-12ER
SLL-12EY
SLL-12EG
SLL-12EW
24 VDC
Model (DC only)
SLL-24ER
SLL-24EY
SLL-24EG
SLL-24EW
Applicable cap (color)
(colored plate)
Selection precautions
Red
Orange
Green
White
In the standard setup, 4 LED lamps are used
with A3PJ models and 2 LED lamps are
used with A3PA and A3PT models.
(LED models)
Rectangular models Square models Round models
Appearance
Selection precautions
Contact
type
Switch
Number of
outputs
Standard load
1c
Silver alloy
contact
2c
3c
Microload
1c
Gold alloy
contact
2c
3c
Operation
Model
Model
Model
Momentary operation
A3PJ-7010-1
A3PA-7010-1
A3PT-7010-2
Alternate operation
A3PJ-7020-1
A3PA-7020-1
A3PT-7020-2
Momentary operation
A3PJ-7030-1
A3PA-7030-1
A3PT-7030-2
Alternate operation
A3PJ-7040-1
A3PA-7040-1
A3PT-7040-2
Momentary operation
A3PJ-7150-1
---
---
Alternate operation
A3PJ-7160-1
---
---
Momentary operation
A3PJ-7050-1
A3PA-7050-1
A3PT-7050-2
Alternate operation
A3PJ-7060-1
A3PA-7060-1
A3PT-7060-2
Momentary operation
A3PJ-7070-1
A3PA-7070-1
A3PT-7070-2
Alternate operation
A3PJ-7080-1
A3PA-7080-1
A3PT-7080-2
Momentary operation
A3PJ-7170-1
---
---
Alternate operation
A3PJ-7180-1
---
---
Ordering set combinations: Refer to page 3 to 5.
The end digit denotes the color
of the flange: -1
denotes a black flange, and -2
denotes a light gray flange.
Round switches are available
only in light gray, and not in
black.
Use the Switch in combination
with the same shape Lamp
(rectangular, square or round).
Example: For rectangular
Lamp A3PJ-5011, select
Switch A3PJ-7@@0-@. On the
Switch itself, however, only 3
digits are shown, as follows:
A3PJ-7@@.
Momentary operation is self-resetting, and alternate operation
is self-holding (i.e., push-on,
push-off).
■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 16.
■ Accessories: Refer to pages 10 to 11.
9
A3P
Ordering Information
Accessories, Replacements, and Tools
Accessories
Name
Socket
Appearance
Classification
Rectangular
Square
Application precautions
Wire-wrap terminal
A3PJ-4101
A3PA-4101
PCB terminal
A3PJ-4102
A3PA-4102
Solder terminal
A3PJ-4103
A3PA-4103
• The Socket cannot be used with
when mounting multiple Switches or with 3C models.
• You can use the same Sockets
for the A3P Ultra Bright Lighted
Pushbutton Switches.
Black
A3PJ-4001
A3PA-4001
Light gray
A3PJ-4002
A3PA-4002
Black
A3PJ-4004
Light gray
A3PJ-4005
Black
A3PJ-4007
A3PA-4007
Light gray
A3PJ-4008
A3PA-4008
Black
A3PJ-4010
Light gray
A3PJ-4011
Short edge barrier
(Horizontal mounting) (1 pair)
Long edge barrier
(Vertical mounting)
(1 pair)
---
Barrier
Short intermediate
barrier (Horizontal
mounting)
Long intermediate
barrier (Vertical
mounting)
• The purpose of the barrier is to
prevent malfunctioning and to
improve design image of the
mounting panel.
• Intermediate barrier × 1.
• Edge barriers × 1 pair (2 Units).
• Mount short barriers horizontally.
• Mount long barriers vertically.
• For details on mounting, refer to
page 23.
• You can use the same Sockets
for the A3P Ultra Bright Lighted
Pushbutton Switches.
---
For horizontal mounting (with
OMRON logo facing down)
A3PJN-5050
A3PAN-5050
For vertical mounting (with OMRON logo facing to the right)
A3PJN-5055
A3PAN-5055
Switch guard
Seal cover
---
A3PJ-5060
A3PA-5060
Long mounting
plate
---
A3PJ-3002
---
• Can be used by exchanging with
the cap.
• Cannot be used with seal cover.
• Can be used with barrier.
• Use horizontal mounting guard
for consecutive horizontal
mounting, and use vertical
mounting guard for consecutive
vertical mounting.
• You can use the same Sockets
for the A3P Ultra Bright Lighted
Pushbutton Switches.
• Cannot be used with barrier and/
or switch guard.
• For details on mounting, refer to
page 23.
• Cap is manufactured from vinyl
chloride.
• You can use the same Sockets
for the A3P Ultra Bright Lighted
Pushbutton Switches.
• Use when vertically mounting individual (with barrier) or multiple
Switches (in standard mounting
style and with barrier). Since a
short mounting plate is attached
to the Switch, replace it with the
long one.
• You can use the same Sockets
for the A3P Ultra Bright Lighted
Pushbutton Switches.
10
A3P
Ordering Information
Accessories
Name
Appearances
Classification
Single screen
Horizontal 2split screen
A3PA
A3PJ-5301
A3PA-5301
Red
A3PJ-5302
A3PA-5302
Green
A3PJ-5303
A3PA-5303
Yellow
A3PJ-5305
A3PA-5305
Orange
A3PJ-5306
A3PA-5306
White
A3PJ-5321
A3PA-5321
Red
A3PJ-5322
A3PA-5322
Green
A3PJ-5323
A3PA-5323
Yellow
A3PJ-5325
A3PA-5325
Orange
A3PJ-5326
A3PA-5326
White
A3PJ-5331
---
Red
A3PJ-5332
---
Yellow
A3PJ-5335
---
Orange
A3PJ-5336
---
White
A3PJ-5361
---
Red
A3PJ-5362
---
Green
A3PJ-5363
---
Orange
A3PJ-5366
---
Horizontal 2-split screen
A3PJ-4302
A3PA-4302
Vertical 2-split screen
A3PJ-4303
---
Long axis
A3PJ-4304
---
Colored plate
for LED
Vertical 2-split
screen
4-split screen
Light baffle
A3PJ
White
Horizontal 3split screen
Short axis
A3PJ-4305
---
Vertical 3-split
screen
Long axis
A3PJ-4306
---
4-split screen
Long axis
A3PJ-4304
---
Transparent legend plate
A3PJ-5202
A3PA-5202
Milk-white legend plate
A3PJ-5201
A3PA-5201
Transparent cap
A3PJ-5600
A3PA-5600
Legend plate
Cap
Crimp-processed transparent cap
Tools
Name
Extractor
Appearance
A3PJ-5600-A
A3PA-5600-A
Classification
Model
---
A3PJ-5080
Application precautions
• Keep mounted at all times.
If the colored plate is lost or damaged, contact OMRON.
• Use in accordance with coloring of
the built-in LED.
• For details on mounting, refer to
page 23.
• You cannot use the same Colored
Plates for Incandescent Lamps for
the A3P Ultra Bright Lighted Pushbutton Switches.
• Keep mounted at all times.
If the light baffle is lost, contact
OMRON.
• Used in LED lamp-lighted models.
Cannot be used in LED-lighted
models.
• You cannot use the same Colored
Plates for Incandescent Lamps for
the A3P Ultra Bright Lighted Pushbutton Switches.
• A transparent legend plate is
mounted on the Pushbutton.
• You cannot use the same Colored
Plates for Incandescent Lamps for
the A3P Ultra Bright Lighted Pushbutton Switches.
• You can use the same Sockets for
the A3P Ultra Bright Lighted Pushbutton Switches.
• The surface is crimp-processed, so
there is no reflection.
• You can use the same Sockets for
the A3P Ultra Bright Lighted Pushbutton Switches.
Application precautions
• Use to extract components when
replacing the Pushbutton.
• You can use the same Sockets for
the A3P Ultra Bright Lighted Pushbutton Switches.
11
A3P
Specifications
Approved Standard Ratings
Ratings
UL (File No. E41515), CSA (File No. LR45258)
Contact Ratings
Silver Alloy Contacts (for Standard Loads)
Standard Load:
Microload:
5 A at 125 VAC
3 A at 250 VAC
0.1 A at 125 VAC
0.1 A at 30 VDC
Rated
voltage
(V)
Note: 1. Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
2. Only Switch output 1c and 2c are certified.
CCC (GB/T14048.5)
Standard Load:
Microload:
3 A at 250 VAC
4 A at 30 VDC
0.1 A at 125 VAC
0.1 A at 30 VDC
Non-inductive load (A)
Resistive load
NC
NO
Inductive load (A)
Lamp load
NC
Inductive load
NO
NC
NO
Motor load
NC
125 VAC
250 VAC
5
3
0.7
0.5
3
2
1.3
0.8
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5
5
4
0.4
0.2
2
2
2
0.05
0.03
4
4
3
0.4
0.2
3
3
3
0.05
0.03
NO
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4; time constant = 7 ms.
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
Standard testing condition
(1) Ambient temperature: 20 ± 2°C
(2) Ambient humidity: 65 ± 5%RH
(3) Operating frequency: 20 times/min.
Note: Only Switch output 1c and 2c are certified.
Gold Alloy Contacts (for Microloads)
0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load)
Rated voltage (V)
Minimum applicable load 1 mA at 5 VDC
LED Ratings
LED for LED-lighted Models
Single screen
Model
Applied
voltage
Rated
voltage
LED Lamp (for LED Lamp-lighted Models)
A3PJ/M2PJ
Current
Red,
white
Approx.
5 VDC±5% 5 VDC
40 mA
12 VAC/VDC 12 VAC/ Approx.
VDC
20 mA
±5%
24 VAC/VDC 24 VAC/ Approx.
VDC
10 mA
±5%
A3PA/M2PA
Current
Red,
white
Approx. Approx. Approx.
20 mA 18 mA 20 mA
Approx. Approx. Approx.
10 mA
8 mA
10 mA
Approx. Approx. Approx.
5 mA
4 mA
10 mA
Orange
Green
Orange
Green
Approx. Approx.
10 mA
9 mA
Approx. Approx.
5 mA
4 mA
Approx. Approx.
5 mA
4 mA
LED for Chameleon Models
Applied voltage
Rated voltage
12 VDC±5%
24 VDC±5%
12 VDC
24 VDC
Current
Green
Approx.26 mA
Approx.13 mA
Red
Approx.20 mA
Approx.10 mA
Type
DC only
Applied
voltage
5 VDC±5%
12 VDC±5%
24 VDC±5%
Rated
voltage
5 VDC
12 VDC
24 VDC
Current
Model
Approx. 30 mA
Approx. 15 mA
Approx. 12.5 mA
SLL-05E@
SLL-12E@
SLL-24E@
• Mis-lighting of the LED
The LED lights with approx. 0.1 mA or less of micro-current. Take
a countermeasure like adding a resistor to prevent mis-lighting in
parallel to the LED.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
(Circuit example)
In case of using 24 VAC/VDC, Direct lighting
X1
LED
lamp
R:10kΩ (1W)
Bleeder resistor
X2
12
A3P
Characteristics
Mechanical
Electrical
Operating frequency
Insulation resistance
Standard load
Microload
Between terminals of same polarity
Between terminals of different polarity
Between current-carrying metal part and ground
Between each terminal and non-current-carrying
metal part
Between lamp terminals
Malfunction
Destruction
Malfunction
Contact resistance
Dielectric strength
Vibration resistance
Shock resistance
Mechanical
Life expectancy
Electrical
Weight
NC
NO
Inrush current
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
120 operations/minute max. *1
30 operations/minute max.
100 MΩ min. (at 500 VDC)
40 mΩ max. (initial value)
40 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1 minute *2
2,000 VAC, 50/60 Hz for 1 minute
2,000 VAC, 50/60 Hz for 1 minute
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute *3
10 to 55 Hz, 1.5 mm double amplitude (1 ms max.)
500 m/s2 max.
200 m/s2 max. (1 ms max.)
Momentary operation models: 1,000,000 operations min.
Alternate operation models: 200,000 operations min.
(One operation consists of set and reset operations.)
100,000 operations min.
Approx. 30 g
Silver contact: 10 A max.
Silver contact: 10 A max.
LED-lighted models: −10°C to 40°C
(with no icing or condensation)
35% to 85%RH
−25°C to 65°C
IP40
Class II
175
3 (IEC947-5-1)
*1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations.
*2. 600 VAC for microloads.
*3. With no LED lamp mounted.
Operating Characteristics
A3PJ series
Model
Operating
Characteristics
Momentary
operation models
A3PA series
Alternate
operation models
Momentary
operation models
A3PT series
Alternate
operation models
Momentary
operation models
Alternate
operation models
Operating force
OF max.
5.88 N
6.86 N
5.88 N
6.86 N
3.92 N
Releasing force
RF min.
0.39 N
0.29 N
0.39 N
0.29 N
0.39 N
4.90 N
0.29 N
Total travel
TT
Approx. 3.5 mm
Approx. 3.5 mm
Approx. 3.5 mm
Approx. 3.5 mm
Approx. 3.5 mm
Approx. 3.5 mm
Pretravel
PT max.
3 mm
3 mm
3 mm
3 mm
3 mm
3 mm
Lock travel alternate
LTA min.
---
0.5 mm
---
0.5 mm
---
0.5 mm
13
A3P
Nomenclature
Model Structure
Lighting
method
Models
Screen
patterns
LED-lighted models
(LED is built-in.)
A3PJ
A3PA
Single
screen
Single
screen
Chameleon
(3-color)
Chameleon
(3-color)
A3PJ
Single
screen
A3PT
Single
screen
Single
screen
Vertical 3-split
screen
Horizontal 2-split Horizontal 3-split
screen
screen
Vertical 2-split
screen
LED-lighted models
LED-lighted models
LED lamp-lighted models
(LED lamp is not built-in.)
A3PA
Horizontal 2-split
screen
4-split screen
LED lamp-lighted models
Chameleon models (full screen
illumination in one of three colors)
Cap
(transparent)
Legend plate
(transparent)
Legend plate
(transparent)
Colored
plate
Colored
plate
LED Unit
LED Unit
3-color emitter
Built-in LED
Cap
(transparent)
Cap
(transparent)
Pushbutton
Legend plate (Split-screen models
(transparent)
contain a light
baffle.)
●Pushbutton
colors
Colored
plate
· LED-lighted models and
LED lamp-lighted models
Lamp
holder
●Switch Specifications
Standard load
· 250 VAC, 3 A
30 VDC, 4A
Microload
· 125 VAC, 0.1 A
30 VDC, 0.1 A
Minimum applicable load: 5 VDC, 1 mA
White, Red, Green, Orange
Lamp
●Case Color
Select either black or light
gray to suit your panel design.
(The round A3PT
models are available in
light gray only.)
Switch
14
A3P
Nomenclature
A3P Lighting Method Diagram
The following diagram shows
the Switches with the
LED-lighted
models
mark facing down.
Single screen
models
• As a set: See page 3.
• Individually: See page 7.
Single screen Horizontal 2-split Vertical 2-split
models
screen models screen models
A3PJ
(rectangular)
LED
models
LED
lamp-lighted
models
Chameleon
models
Vertical 3-split Horizontal 3-split 4-split screen
screen models screen models
Single screen
models
• Individually: See page 7.
(Not available as a set.)
• As a set: See page 3.
• Individually: See page 7.
(Full screen illumination
in one of three colors)
LED-lighted
models
A3PA
(square)
LED
models
LED
lamp-lighted
models
Chameleon
models
A3PT
(round)
LED
models
LED
lamp-lighted
models
Single screen
models
Single screen Horizontal 2-split
screen models
models
Single screen
models
Single screen
models
• As a set: See page 4.
• Individually: See page 7.
• Individually: See page 7.
(Not available as a set.)
• As a set: See page 4.
• Individually: See page 7.
• As a set: See page 5.
• Individually: See page 7.
15
A3P
Dimensions
(Unit: mm)
The Dimension shows switch output 2c.
A3PJ (Rectangular) Models
A3PA (Square) Models
2.8
26.1
22
29.9±0.2
0.5
OMRON logo
OMRON logo
25±0.1
#110 quick connect terminal/
solder terminal
22.9±0.2
18.9
6.7
32±0.1
43.6
Separator
19.1 × 19.1
25±0.1
25±0.1
#110 quick connect terminal/
solder terminal
22.9±0.2
6.7
43.6
52 max.
52 max.
52.6
52.6
Separator
A3PT (Round) Models
#110 quick connect terminal/solder terminal
22.4 28.5 dia.
OMRON logo
24.9 dia.
32 dia.
23.8
6.4
43.6
52 max.
52.6
Note: The thickness of tab terminals #110 and solder terminals is 0.5 mm.
16
A3P
Dimensions
(Unit: mm)
Terminal connections
LED-lighted Models
(The terminal arrangement diagram shows switch output 1c. Connections to terminals from the lighting block are the same for switch output 2c.)
Rated voltage
Screen
Model
pattern
5 VDC
12 VAC/VDC
Bottom view
Top view
Bottom view
Terminal
arrangement
Lighting block
Terminal
arrangement
Top view
24 VAC/VDC
Bottom view
Top view
Terminal
arrangement
Lighting block
Single screen
A3PJ
Bottom view
Top view
Lighting block
Bottom view
Top view
Single screen
A3PA
Terminal
Lighting block
arrangement
Terminal
Lighting block
arrangement
17
A3P
Dimensions
(Unit: mm)
LED Lamp-lighted Models
(All are shown with the OMRON logo facing down.)
Model
Rectangular A3PJ models
Output
Bottom view
Top view
Square A3PA models
Bottom view
Bottom view
Top view
NO1
NO1
NO1
LC+
LC+
NC1
SPDT
Top view
Round A3PT models
NC1
LC+
C1
NC1
C1
Terminal
arrangement
C1
Lighting block
Terminal
arrangement
Lighting block
Top view
Bottom view
Top view
Bottom view
Lighting block
Terminal
arrangement
Bottom view
Top view
NO1 NO2
NO1 NO2
PPDT
LC+
NC1 NC2
C1 C2
LC+
NO1 NO2
LC+
NC1 NC2
C1
C2
NC1
C1
Terminal
arrangement
Lighting block
Bottom view
Top view
Terminal
arrangement
Lighting block
NC2
C2
Terminal
arrangement
Lighting block
NO1 NO2 NO3
3PDT
NC1 NC2 NC3
C1 C2 C3
---
LC+
Terminal
arrangement
---
Lighting block
LED Chameleon Models
(The terminal arrangement diagram shows switch output 1c. Connections to terminals from the lighting block are the same for switch output 2c.)
Rated voltage
Model
24 VDC
Rectangular
A3PJ model
NO1
Square A3PA
model
L2−
NC1
L4−
C1
L3−
L1−
LC+
NO1 L1−
LC+
NC1 L2−
C1
Terminal Arrangement and Coloring
Chameleon Models
Wiring
Coloring
LC+
LC+
L1−
L2−
Green
Red
LC+
L1− and L2−
shorted
Orange
18
A3P
Dimensions
(Unit: mm)
Panel Cutout (If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 21.)
A3PJ (Rectangular) Models
Classification
Individual
mounting
(Horizontal)
Multiple
mounting
(Horizontal)
Flange
mount
models
Individual
mounting
(Vertical)
Multiple
mounting
(Vertical)
Barrier
mount
models
Mounting design
23.5±0.3
32±0.1
25±0.1
1
32n−1.5 ±0.3
n
2
Mount to long
mounting plate
(A3PJ-3002)
before use.
32±0.1
25±0.1
1
2
Mount to long
mounting plate
(A3PJ-3002)
before use.
n
25n±0.5
Individual
mounting
(Horizontal)
27
Multiple
mounting
(Horizontal)
27
1
6 min.
30.5±0.3
25n−1.5 ±0.3
30.5±0.3
1
32.9n+3.5±0.3
n
2
23.5±0.3
Mount to long
mounting plate
(A3PJ-3002)
before use.
34
34
23.5±0.3
23.5±0.3
33n+6±1
Multiple
mounting
(Vertical)
3 min.
36.4±0.3
39
Individual
mounting
(Horizontal)
Panel cutout spacing between rows of Units:
23.5±0.3
32n±0.5
32±0.1
Remarks
30.5±0.3
25±0.1
32±0.1
Note: 1.
2.
3.
4.
Panel cutout
2
n
26n+6±1
Mount to long
mounting plate
(A3PJ-3002)
before use.
For barrier mount models, refer to Accessories on
page 10.
Panel cutout spacing between rows of Units:
(Dotted line indicates the position of each mounting
barrier.)
29.4±0.3
1.3
30.5±0.3
6 min.
6 min.
25.9n+3.5±0.3
30.5±0.3
n: Number of Units
Recommended panel thickness: 1 to 5 mm
Mount the panel before mounting the Switch Guard.
If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
A3PA (Square) Models
Classification
Individual
mounting
Flange
mount
models
Mounting design
Panel cutout
6 min.
25±0.1
1
23.5±0.3
n
2
25n−2.5 ±0.3
25n±0.1
Individual
mounting
Barrier
mount
models
27
27.8±0.3
1
2
26n+6.5±1
Note: 1.
2.
3.
4.
Panel cutout spacing between rows of Units:
(Dotted line indicates the position of each mounting barrier.)
23.5±0.3
27
32
Multiple
mounting
3 min.
22.5±0.3
25±0.1
Multiple
mounting
Panel cutout spacing between rows of Units:
23.5±0.3
25±0.1
Remarks
n
1.3
6 min.
6 min.
23.5±0.3
26n+2.5±0.3
n: Number of Units
Recommended panel thickness: 1 to 5 mm
Mount the panel before mounting the Switch Guard.
If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
A3PT (Round) Models
6.4 dia.
+0.2
11.8R −0
29±0.3 dia.
4 min.
Note: 1. Recommended panel thickness: 1 to 5 mm
2. If the panel is to be finished (e.g., coated), make sure that the panel
meets the specified dimensions after the coating.
19
A3P
Dimensions
(Unit: mm)
Accessory Mounting Dimensions
Legend Plate
Rectangular Models
A3PJ-5201/-5202
Extractor
A3PJ-5080
Square Models
A3PA-5201/-5202
25.1
20
2.5
2.5
17.2
15
16.9
17.2
50
Plate surface 1.2
10
5
0.3
1.5
25±2
Note: Made from stainless steel.
1.5
24
Socket-mounting Dimensions
Rectangular Models A3PJ (M2PJ)
Square Models A3PA (M2PA)
Wire-wrap Terminal
A3PJ-4101
Wire-wrap Terminal
A3PA-4101
25.6
18
25.6
18
24
31.8
1 × 1 Wire-wrap Terminal
1 × 1 Wire-wrap Terminal
22.8
22.8
61.6
61.6
25.6
PCB Terminal
A3PJ-4102
18.5±0.8
PCB Terminal
A3PA-4102
18
18.5±0.8
25.6
18
3
1.2
3
1.2
24
31.8
0.3
0.3
22.8
22.8
61.6
61.6
0.5
3.6
PCB Cutout
(bottom view)
3.6
PCB Cutout
(bottom view)
0.5
1.5
17.4
8.7
5.2
2.05
10.4
17.6
10.5
8.65
1.25
3.5
7
6.15
8.8
5.25
8.4
Eleven, 1.5-dia. holes
Nine, 1.5-dia. holes
10.2
20.45
7 11.65
Solder Terminal
A3PJ-4103
25.6
Solder Terminal
A3PA-4103
25.6
18
3
31.8
18
3
Terminal Hole
Dimensions
Terminal Hole
Dimensions
0.8
0.8
0.3
24
0.3
3.2
3.2
3
3
0.9R
22.8
22.8
0.6R
61.6
61.6
8.2
0.9R
0.6R
8.2
Note: PCB cutout dimensions show the switch mounted to the socket with the OMRON logo facing down.
20
A3P
Dimensions
(Unit: mm)
Switch and Guard Mounting Dimensions
Rectangular Models
A3PJN-5050 (Horizontal Mounting)
A3PJN-5055 (Vertical Mounting)
Spring
25±0.1
52.6
52 max.
43.6
9.6
Square Models
A3PAN-5050 (Horizontal Mounting)
A3PAN-5055 (Vertical Mounting)
Spring
25±0.1
25.2
Switch Guard
(A3PJN-5050)
52.6
52 max.
43.6
9.6
25.4
25±0.1
32±0.1
Guard
Switch Guard
(A3AN-5050)
OMRON logo
OMRON logo
19.1
26.2±0.2
Panel Cutouts
Individual Mounting
(Horizontal)
Panel Cutouts
Individual Mounting
(Horizontal)
Multiple Mounting
(Horizontal)
Multiple Mounting
(Horizontal)
22.5±0.3
25n-2.5 ±0.3
32n-1.5 ±0.3
30.5±0.3
23.5±0.3
23.5±0.3
23.5±0.3
23.5±0.3
n = Number of mountings
n = Number of mountings
Note: Multiple vertical mounting is not possible.
Note: Multiple vertical mounting is not possible.
Seal Cover Mounting Dimensions
Rectangular Models
A3PJ-5060
Cover A (transparent) Cover B (black)
Seal Cover
(A3PJ-5060)
Square Models
A3PA-5060
Cover A (transparent) Cover B (black)
OMRON logo
32.5
Seal cover
(A3PA-5060)
OMRON logo
32.5
39.5
9.3
42.9
32.5
8.7
51.3 max.
51.9
Multiple Mounting
(Horizontal)
Panel Cutouts
Individual Mounting
(Horizontal)
42.9
51.3 max.
51.9
Panel Cutouts
Individual Mounting
Multiple Mounting
9.5 min.
22.5±0.3 10.5 min.
30.5±0.3
22.5±0.3
30.5±0.3
23.5±0.3
23.5±0.3
9.5 min.
23.5±0.3
23.5±0.3
9.5 min.
Note: 1. Recommended panel thickness: 1 to 5 mm
2. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
21
A3P
Safety Precautions
Refer to Safety Precautions for all Pushbutton Switches/Indicators.
Caution
Precautions for Correct Use
1. Always make sure that the power is turned OFF before mounting,
removing, or wiring the Switch, or performing maintenance.
Electric shock or fire may occur.
2. After wiring the Switch, make sure that there is a suitable isolation
distance.
Wiring
• Solder quickly and correctly at 350°C max and for 3 s or less.
Wait for one minute after soldering before exerting any external
force on the solder.
Operating Environment
• Do not use in locations that are subject to dust, oil, or metal filings
as these may penetrate the interior of the Switch and cause
malfunction.
Using Microloads
• Using a standard load switch when a microload circuit is opened or
closed may cause contact failure on the contacts. Use the switch
within the operating range. (Refer to the diagram below.) Even
when using microload models within the operating range shown
below, if inrush current occurs when the contact is opened or
closed, it may cause the contact surface to become rough, and so
decrease life expectancy. Therefore, insert a contact protection
circuit where necessary. The minimum applicable load is the Nlevel reference value. This value indicates the malfunction
reference level for the reliability level of 60% (λ 60) (conforming to
JIS C5003). The equation, λ 60 = 0.5 x 10−6/time indicates that the
estimated malfunction rate is less than 1/2,000,000 with a reliability
level of 60%.
Voltage (V)
Do not apply a voltage higher than the maximum
rated operating voltage between the lamp
terminals, as there is a risk that LED will be
damaged, and the Pushbutton will be ejected.
30
26 mA 100 mA
0.15 mA
24
LED (for VDC)
• Check the terminal polarity when wiring.
• The rated voltage is shown on the plate on the back of the lighting
unit, so be sure to use within the voltage shown.
• An LED current-limiting resistor is built in, so there is no need to
mount an external resistor.
Character Plate (Character Film)
• If preparing the character plate separately, use a heat-resistant film
with a thickness of 0.1 to 0.3 mm.
24.1 +0
−0.1
12
Invalid
area
5
1 mA
100 mA 160 mA
0
0.1
1
10
100
1,000
Current (mA)
Others
17.1 +0
−0.3
17.1 +0
−0.3
Standard
load area
Microload
area
17.1 +0
−0.3
• If the panel is to be finished (e.g., coated), make sure that the panel
meets the specified dimensions after the coating.
24.8 +0
dia.
−0.3
23.±0.1 dia.
5.2+0
−0.3
22
A3P
Assembly/Disassembly
A3PJ/M2PJ (Rectangular Models), A3PA/M2PA (Square Models)
Locking/Unlocking Positive Cap Lock Mechanism
Lock
Unlock
Positive cap stopper
Mounting Pushbutton
• Be sure to mount the Pushbutton with the correct orientation. Align
the groove on the Pushbutton, the projections in the Switch, and the
LED contact piece before pushing the Pushbutton into the Switch.
• When dismounting the Pushbutton, use the Extractor (A3PJ-5080)
for easy dismounting.
OMRON logo
Groove
Mounting and Replacing LED Lamps
If using a square model with one LED lamp, insert the lamp in the
center hole.
Note: Built-in LEDs cannot be replaced.
LED Rated Voltage Display (LED Models Only)
The LED rated voltage is shown between the built-in resistors on the
back of the lighting unit. Use within a range of ± 5%.
A3PJ
Rated
voltage display
A3PA
LED contact piece
Diagram shows A3PA model.
Removing/Mounting Cap
Insert the A3PA from the open side into the theft-prevention stopper.
Note: Display is on the back.
Mounting Switch onto Panel
Mounting Colored Plate
Place the colored plate on the plunger case with the dull side of the
colored plate facing downward.
With A3PJ split-screen models, be sure that the projections on the
upper surface of the colored plate face outward. For the A3PA, make
sure that the flat plate is facing upwards.
• Individual Mounting
and Barrier Mounting
When mounting the Switch,
push it into the panel cutout
from the front of the
mounting panel by holding it
with the logo mark
“OMRON” facing downward.
• Multiple Barrier Mounting (A3PJ)
When mounting a number of Switches in
line on the panel, link the Switches with
spacing barriers in between, attach
mounting barriers at both sides of this block
of Switches and, pushing in on the
mounting barriers at the side, insert the
Switches into the panel cutout together.
Flat plate
Projection
OMRON
logo
OMRON
logo
A3PA
A3PJ
Mounting Barriers
Mount each part by pushing it in the direction of the arrow shown in
the corresponding illustration below.
Mounting Character Plate (Character Frame) and Legend
Plate
Mount the legend plate for the A3PJ under the layered surfaces and
mount the cap, as shown below.
Barrier mounting
Transparent cap
Legend plate
(Character plate)
Colored plate
(Light baffle)
23
A3P
Mounting Seal Cover
After mounting the seal cover onto the flange of the Switch, push the
Switch into the panel cutout.
Inscribing the Legend Plate
• Inscribe the legend plate to a depth of 0.5 mm max.
• The legend plate is made from polycarbonate resin. To coat the
legend plate, use an alcohol-based coating such as melamine,
phthalic acid, or acrylic.
Maintenance Lock
1. First, when you insert the transparent lens while pressing the
center, the maintenance lock mechanism will be activated, and the
Switch will not operate. Lamp replacement and other maintenance
can be performed without turning OFF the power supply to devices
and equipment. Use an insertion force of 4 kg.
2. Next, when you remove your finger from the Switch, the lock will be
released.
3. The Switch will start to operate when the lighting unit is pressed the
second time.
24
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2022.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2022 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
A3PJ-5080 A3PA-4001 A3PA-4101 A3PA-4102 A3PA-4103 A3PA-5011 A3PA-5012 A3PA-5050 A3PA-5060
A3PA-5101 A3PA-5106 A3PA-5121 A3PA-5201 A3PA-5202 A3PA-5600 A3PA-5701-06E A3PA-5701-12E A3PA5701-24E A3PA-5702-05E A3PA-5702-12E A3PA-5702-24E A3PA-5703-05E A3PA-5703-24E A3PA-5706-05E
A3PA-5706-12E A3PA-5706-24E A3PA-5711-24E A3PA-5712-O5E A3PA-5713-24E A3PA-5716-24E A3PA-572324E A3PA-5731-24E A3PA-5732-24E A3PA-5733-24E A3PA-5736-05E A3PA-5736-12E A3PA-5742-24E A3PA5746-24E A3PA-5803-24E A3PA-7010-1 A3PA-7020-1 A3PA-7030-1 A3PA-7040-1 A3PA-7050-1 A3PA-7070-1
A3PA-90A11-24EG A3PA-90A11-24EO A3PA-90A11-24ER A3PA-90A11-24EW A3PA-90A11-28 A3PA-90C12-28
A3PA-90D11-06 A3PJ-3002 A3PJ-4001 A3PJ-4002 A3PJ-4004 A3PJ-4007 A3PJ-4010 A3PJ-4102 A3PJ-4103
A3PJ-4302 A3PJ-4305 A3PJ-4308 A3PJ-4501 A3PJ-5011 A3PJ-5012 A3PJ-5014 A3PJ-5016 A3PJ-5021 A3PJ5022 A3PJ-5023 A3PJ-5050 A3PJ-5055 A3PJ-5060 A3PJ-5101 A3PJ-5103 A3PJ-5122 A3PJ-5124 A3PJ-5125
A3PJ-5161 A3PJ-5162 A3PJ-5165 A3PJ-5166 A3PJ-5201 A3PJ-5202 A3PJ-5207 A3PJ-5502 A3PJ-5600 A3PJ5701-05E A3PJ-5701-12E A3PJ-5701-24E A3PJ-5702-06E A3PJ-5702-12E A3PJ-5702-24E A3PJ-5703-24E
A3PJ-5706-24E A3PJ-5711-24E A3PJ-5712-12E A3PJ-5712-24E A3PJ-5713-12E