SG-B5T-010A
Confidential
OMRON CORPORATION
Image Sensing Component
HVC-P
Evaluation Software
Driver Installation
Manual
Confidential
SG-B5T-010A
TABLE OF CONTENTS
1 Preparations
・・・ 02
2 Install COM Drivers
2.1 Automatic Installation
2.2 Verify Installation
2.3 Reinstallation
2.4 Manual Installation
・・・ 03
・・・ 04
・・・ 05
・・・ 06
・・・ 12
3 Run Application
3.1 Set Device Baud Rate
3.2 Set Application Baud Rate
・・・ 18
・・・ 18
・・・ 19
4 Troubleshooting
4.1 Display during Installation
4.2 Change USB Drivers Settings
4.3 Set COM Port Settings
4.4 Caution while using the Application
4.5 Delete Drivers
4.6 Update Drivers
・・・ 20
・・・ 23
・・・ 24
・・・ 25
・・・ 27
・・・ 28
・・・ 30
5 Information
・・・ 32
Installation Check Sheet
・・・ 33
■ Revision History
Date
Rev Contents
2014/01/30
A
First release
Additional Notes
You may not reproduce the contents of this document without proper written authorization from OMRON
Corporation.
You may not copy the contents of this document except for the purpose of evaluating the HVC-P sample.
The contents of this document may change without notice.
Copyright (C)2014 OMRON Corporation, All rights reserved.
1
Confidential
SG-B5T-010A
This document provides details on how to use the HVC-P device
(hereafter referred to as “the Device” and the HVC-P Evaluation
Software (hereafter referred to as “the Application”).
1 Preparations
●Items to Prepare
・A PC with high-speed Internet connection (running Windows 7).
・As administrator privileges are required for the installation, we
recommend using a PC with an administrator account login.
・USB 2.0 cable (A male to B male) (not included).
●Installation Procedure
・Follow the instructions described in 2 Install COM Drivers.
・Use the Installation Check Sheet provided at the end of the
installation manual. Please refer to it when contacting the HVC
Customer Service with issues regarding the installation.
●Operating Environment
The Application was tested in the following environment.
・OS
Windows 7 Professional SP1 64bit / 32bit
・CPU
Intel® Core™ i7-3770 CPU @ 3.40GHz
Please note that errors might occur due to the specs of the PC used.
Please refer to 4 Troubleshooting for details.
Windows and Windows7 are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.
Intel and Intel Core are registered trademarks or trademarks of Intel Corporation in the United States and other countries.
Other product and service names are registerd trademarks or trademarks of respective owners.
Copyright (C)2014 OMRON Corporation, All rights reserved.
2
Confidential
SG-B5T-010A
2 Install COM Drivers
Please follow sections 2.1 and 2.2 for installing the drivers.
Please refer to sections 2.3 and 2.4 should errors occur.
START
Section 2.1
Section 2.2
Verification in the Device Manager
COM# display
Displayed under “Other devices”
Section 2.3
COM# display
If “install was not successful”
Section 2.4
COM# display
Run the Application
Copyright (C)2014 OMRON Corporation, All rights reserved.
3
Confidential
SG-B5T-010A
2.1 Automatic Installation
① Start the PC if not already running.
② Verify that the Internet connection is working.
③ Close any running application.
④ Connect the Device to the PC with the USB cable.
⑤ The installation will start shortly.
⑥ The windows below will be usually displayed during the
installation, but not always. In such a case, proceed to
Section 2.2 after a few moments.
The status is displayed as below.
The installation may take a
few minutes. Please do not
click on “Close” until the
installation is complete.
×クリックしない
×Do not click to close
⑦ The windows above will change to the ones below when the
installation is complete, but sometimes nothing will be displayed.
Regardless, proceed to Section 2.2 after a few moments.
Copyright (C)2014 OMRON Corporation, All rights reserved.
4
Confidential
SG-B5T-010A
2.2 Verify Installation
Verify the COM port number in the device manager.
① Start the PC if not already running.
② Verify that the Internet connection is working.
③ Close any running application.
④ Connect the Device to the PC with the USB cable.
⑤ Open Device Manager on the PC.
From “Start” go to “Computer”, right-click it and select “Manage”.
⑥ Click on Device Manager
⑦ Proceed to Section 3.1 if “USB Serial Port(COM#)” is displayed
under “Ports (COM & LPT)”.
Verify the COM number of the port. The
COM number is COM4 in the example to
the left. Write it down for later.
⑧ Proceed to Section 2.3 if it is listed under “Other devices”.
Copyright (C)2014 OMRON Corporation, All rights reserved.
5
Confidential
SG-B5T-010A
2.3 Reinstallation
Reinstall the drivers if the COM number was not displayed.
Follow instructions ① to ⑥ as in Section 2.2.
Proceed to ⑩ if “USB Serial Port” is displayed under “Other
devices”.
Proceed to ⑦ if “FT232R USB UART” is displayed.
⑦ When “FT232R USB UART” is displayed, right click on it.
If “Scan for hardware changes” is displayed, verify the Internet
connection and return to ③ in Section 2.1.
If “Update Driver Software” is displayed, select it and proceed to ⑧.
Copyright (C)2014 OMRON Corporation, All rights reserved.
6
Confidential
SG-B5T-010A
⑧ Driver Software Update
Click on “Search automatically…”
⑨ The update driver software windows will be as displayed below
when searching for the drivers.
Copyright (C)2014 OMRON Corporation, All rights reserved.
7
Confidential
SG-B5T-010A
If “Windows has successfully…” is displayed, disconnect the USB
cable and restart from Section 2.3 to verify the USB Serial Port
display.
Proceed to Section 2.4 if the device driver was not successfully
installed.
Copyright (C)2014 OMRON Corporation, All rights reserved.
8
Confidential
SG-B5T-010A
⑩ USB Serial Port Display
If the menu to the left is displayed,
verify that the PC is connected to
the Internet and restart from ③.
Click on “Update Driver Software”
⑪ Update Driver Software
Click on “Search automatically …”.
Copyright (C)2014 OMRON Corporation, All rights reserved.
9
Confidential
SG-B5T-010A
⑫The “Update driver software” windows will be as displayed below.
If “Windows has successfully…” is displayed, proceed to ⑬.
Copyright (C)2014 OMRON Corporation, All rights reserved.
10
Confidential
SG-B5T-010A
Proceed to Section 2.4 if the device driver was not successfully
installed.
⑬ Verify the COM number in “Ports (COM & LPT)” in the Device
Manager.
Verify the COM number of the port. The COM
number is COM4 in the example above. Write it
down for later.
⑭ Proceed to 3 Run Application.
Copyright (C)2014 OMRON Corporation, All rights reserved.
11
Confidential
SG-B5T-010A
2.4 Manual Installation
① Confirm the Operating System type.
Confirm the System type (32-bit/64-bit) and download the
appropriate drivers.
② Download the drivers.
The VCP drivers can be downloaded from the FTDI website.
http://www.ftdichip.com/Drivers/VCP.htm
32-bit version
64-bit version
Copyright (C)2014 OMRON Corporation, All rights reserved.
12
Confidential
SG-B5T-010A
③ Download the files.
Click on “Save”
Example: Save in Downloads
④ Unzip the files
Unzip the downloaded CDM 2.08.30 WHQL Certified.zip file.
Further unzip the CDM v2.08.30 WHQL Certified.zip file.
This will create the CDM v2.08.30 WHQL Certified folder.
Copyright (C)2014 OMRON Corporation, All rights reserved.
13
Confidential
SG-B5T-010A
⑤ Connect the HVC-P to the PC with the USB cable.
⑥ The installation will start shortly.
⑦ The windows below will be displayed during the installation.
⑧ Open the Device Manager.
From “Start” go to “Computer” and right-click on “Manage”.
Copyright (C)2014 OMRON Corporation, All rights reserved.
14
Confidential
SG-B5T-010A
⑨ Click on “Device Manager”, then “Other devices”.
⑩ Right-click on “USB Serial Port”.
Click on “Update Driver Software”.
⑪ Update the driver software.
Click on “Browse my computer…”
Copyright (C)2014 OMRON Corporation, All rights reserved.
15
Confidential
SG-B5T-010A
⑫ Click on “Browse” and select the folder unzipped earlier.
⑬ Click on “Next”.
Copyright (C)2014 OMRON Corporation, All rights reserved.
16
Confidential
SG-B5T-010A
⑭ Close the window if “Windows has successfully…” is displayed.
⑮ Verify the COM number in “Ports (COM & LPT)” in the Device
Manager.
The installation is complete if “USB Serial Port (COM#)” is
displayed.
Verify the COM number of the port. The COM number
is COM4 in the example above. Write it down for later.
Proceed to 3 Run Application.
⑯ If the above is not displayed, proceed to Section 4.5.
Copyright (C)2014 OMRON Corporation, All rights reserved.
17
Confidential
SG-B5T-010A
3 Run Application
Please make sure to also refer to the HVC-P Evaluation
Software Manual before using the Application
3.1 Set Device Baud Rate
This is for the transmission rate for the UART signal of the Device.
The possible values are 9600, 38400, 115200, 230400, 460800,
921600 (921600 is the default value).
Make sure that the Baud rate set in the Application matches the
value manually set on the Device.
Setting the Baud rate on the Device must be done manually
through the DIP switch (identified as SW-2 on the image below) on
the back of the Device.
SW2
ON
OFF
SW2-4
SW2-3
SW2-2
SW2-1
Make sure to leave SW2-1 to ON at all times.
The possible settings for SW2-2, SW2-3 and SW2-4 are displayed
below.
□
:9600
□□□
□□
:38400
□
□
□
□ :460800
□□
□□
□
:230400
□
□□□
:115200
□
□□
□ :921600
□
Please refer to the HVC-P Instruction Sheet for details.
Copyright (C)2014 OMRON Corporation, All rights reserved.
18
Confidential
SG-B5T-010A
3.2 Set Application Baud Rate
Click on the “HVC-PDemo.exe” file
to start the Application.
The window displayed below will open the first time the
Application is run.
Select the Port number written down from in Section 2.2.
③ Select the Baud rate.
Make sure to select the Baud rate matching the value manually
set for the Device.
④ Click on “Connect” to start the Application.
Copyright (C)2014 OMRON Corporation, All rights reserved.
19
Confidential
SG-B5T-010A
4 Troubleshooting
The Device won’t power-up.
Location of the LED
Suspected cause The cable or connector is not working properly.
Items to verify
① Verify the USB cable connection to the PC.
② Verify the USB cable connection to the Device.
Error Message:
Device driver software was not successfully installed
Suspected cause
The driver installation failed.
Items to verify
① Reinstall the drivers as described in Section 2-3.
“Other devices” is displayed in the Device Manager
Suspected cause
The driver installation is not complete.
Items to verify
① Reinstall the drivers as described in Section 2-3.
Copyright (C)2014 OMRON Corporation, All rights reserved.
20
Confidential
SG-B5T-010A
The Port (COM#) is unknown.
Items to verify
① Identify the Port (COM#) from the Device Manager.
Please refer to Section 2.2 for details.
Error message:
Device is not responding.
Please verify connection.
Suspected cause
① The cable is not properly connected.
② The transmission setting is incorrect.
③ The USB driver install was not completed.
④ The port setting (COM#) is incorrect.
⑤ The drivers are updated.
Items to verify
① Verify the cable and the connector.
② Verify the Baud rate setting on the Device (refer to Section 3.1)
and in the Application (refer to Section 3.2).
Verify the Port (COM#) setting in the Device Manager (refer to
Section 2.2).
③ Verify that the driver installation is complete. Refer to Section
4.1 to see the windows displayed while the installation is still
running.
④ Change the Port (COM#) settings (refer to Section 4.3)
⑤ Update the drivers (refer to Section 4.6).
Copyright (C)2014 OMRON Corporation, All rights reserved.
21
Confidential
SG-B5T-010A
Error message:
Communication error.
Please lower the Baud rate or change the USB driver settings.
Suspected cause
The PC used is not powerful enough.
Items to verify
① Lower the Baud rate setting.
Change the setting on the Device (refer to Section 3.1) and in
the Application (refer to Section 3.2).
② Change the USB driver settings (refer to Section 4.2).
Please contact the HVC Customer Service should any issue
continue to occur.
Contact information is given in the HVC-P Instruction Sheet.
Copyright (C)2014 OMRON Corporation, All rights reserved.
22
Confidential
SG-B5T-010A
4.1 Display during Installation
The windows below will be displayed during the installation of the
USB drivers.
The status is displayed as below.
Clicking on the “Show hidden icons” button on the taskbar will
display the following windows. The status of the driver installation
can be verified from here.
Click on the USB driver icon.
Copyright (C)2014 OMRON Corporation, All rights reserved.
23
Confidential
SG-B5T-010A
4.2 Change USB Driver Settings
Right click on the “USB Serial Port(COM#)” displayed under “Ports
(COM & LPT) in the Device Manager and select “Properties”.
Click on “Advanced” in the “Port Settings” tab.
The transmission performance will improve if the “Latency Timer
(msec)” in “BM Options” is set lower than 16.
However, setting the value too low will increase the rate of
interruption of the USB and increase the load on the system. Please
make sure to set a balanced value.
Copyright (C)2014 OMRON Corporation, All rights reserved.
24
Confidential
SG-B5T-010A
4.3 Change COM Port Settings
The Port COM# identified in Section 2 is sometimes not displayed in
the Port setting of the Application.
In the example below, the device manager displays COM3 but it is
not displayed in the Port setting of the Application.
COM4 is not displayed.
Refer to ⑤ to ⑦ of Section 2.2 on how to access the Device
Manager.
Right click on the “USB Serial Port (COM#)” displayed under
“Ports (COM & LPT).
Copyright (C)2014 OMRON Corporation, All rights reserved.
25
Confidential
SG-B5T-010A
Open “Advanced” in the “USB Serial Port (COM#) Properties”
window.
Click on “COM Port Number” and select an available COM#, i.e. one
that is not “(in use)”.
Select a different COM# if the same error message appears.
Choose a COM# not “(in use)”.
For example, using COM5 will result in an
error but using any non-used COM# after
COM6 is fine.
Click “OK” to close the window.
Copyright (C)2014 OMRON Corporation, All rights reserved.
26
Confidential
SG-B5T-010A
4.4 Caution while Using the Application
“Continuous”
execution button
Display when process not running
Display when process is running
Changing the transfer image size or clicking on the “x” to close the
Application while a detection process is running (the “Continuous”
button has been clicked once) will display a “Please wait.” message
and the Application may sometimes freeze.
Please make sure to click on the “Continuous” button a second time
to stop the running process before changing the transfer image size
or closing the Application.
Copyright (C)2014 OMRON Corporation, All rights reserved.
27
Confidential
SG-B5T-010A
4.5 Delete Driver
If the drivers still cannot be successfully installed after following
Section 2.3 and 2.4, delete them once before trying again.
Proceed from ① to ④ of Section 2.1.
⑤ Open the Device Manager.
⑥ Click on “Device Manager”.
The image below displays the Device Manager when the USB
serial port is listed under “Other devices”.
Copyright (C)2014 OMRON Corporation, All rights reserved.
28
Confidential
SG-B5T-010A
⑦ Select “USB Serial Port” and right-click.
Click on “Uninstall”
⑧ Click “OK”.
⑨ Verify that the USB serial ports was deleted from the Device
Manager.
⑩ Disconnect the USB cable from the PC.
When reinstalling, start from Section 2.1.
Copyright (C)2014 OMRON Corporation, All rights reserved.
29
Confidential
SG-B5T-010A
4.6 Update Drivers
Drivers update may be required when the Application is not running
properly.
Proceed from ① to ⑥ of Section 2.2.
右クリック
クリック
⑦ Right click on “USB Serial Port (COM#) and select “Update
Driver Software”
⑧ Update the drivers.
Click on “Search automatically...”
Copyright (C)2014 OMRON Corporation, All rights reserved.
30
Confidential
SG-B5T-010A
⑨ The windows below will be displayed when updating the drivers.
⑩ Verify the COM number in “Ports (COM & LPT)” in the Device
Manager.
Verify the COM number of the port. The COM number is COM4 in the
example above. Write it down for later
Copyright (C)2014 OMRON Corporation, All rights reserved.
31
Confidential
SG-B5T-010A
5 Information
The Device is using the FT232R drivers from FTDI.
The latest VCP (Virtual COM Port) drivers can be downloaded from
FTDI’s website.
・FTDI website
http://www.ftdichip.com/
・Latest drivers
http://www.ftdichip.com/Drivers/VCP.htm
Copyright (C)2014 OMRON Corporation, All rights reserved.
32
Confidential
SG-B5T-010A
Installation Check Sheet
Please use the check sheet when proceeding with the installation.
Preparations
□ PC with an Internet Connection
Maker/Model
OS (Windows Edition)
System
Processor
RAM
System Type
bit
_
_
P2
_
_
□ Administrator Privileges
□ USB 2.0 cable (A male to B male)
Driver Installation
□ COM#
COM
P3 to P17
_
This is the COM number displayed after a successful installation.
Baud Rate Setting
□ DIP-SW setting of the Device
□ 9600
□ 38400
□ 230400
□ 460800
□ 115200
□ 921600
P18
□ Baud Rate setting of the Application
□ 9600
□ 38400
□ 115200
□ 230400
□ 460800
□ 921600
P19
Copyright (C)2014 OMRON Corporation, All rights reserved.
33