0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
C200H-TV003

C200H-TV003

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    TEMP CTRL MOD 1 ANALOG 1 ANALOG

  • 数据手册
  • 价格&库存
C200H-TV003 数据手册
INTRODUCTION M O R E P O W E R . M O R E F L E X I B I L I T Y. M O R E S P E E D . Like our popular C200H/HS mid-size PLC series, Omron’s new C200Hα series offers the advantages of large PLC performance and I/O versatility in a mid-size PLC package and price range. But there’s more to the new C200Hα series—a lot more. WHY OMRON? Improvements to the existing series, such as greater memory capacity and faster processing speed, strengthen the C200Hα series’ capabilities as a controller. Newly added features, such as a protocol macro and an optional PCMCIA Card Module, transform the C200Hα series into a powerful on-site data processing system—and transforms your workplace into a highly responsive, information-based operation. Your 24-Hour Automation Solution 880 1,184 maximum More Special I/O Modules C200HS 10 C200Hα 16 Increased Processing Speed 0.375 µs LD execution 0.1µs LD execution speed C200HS C200Hα Increased Memory Capacity C200HS 15.2k words C200Hα 31.2k words maximum Increased Data Memory C200HS 6K words C200Hα 24K words maximum Enlarged SYSMAC LINK Data Link Area C200HS C200Hα 918 words 2,966 words Increased Local Expansion C200HS C200Hα Omron performs 100% quality inspection and testing procedures at every stage of manufacturing – your assurance of satisfaction. Get Omron’s SmartFactory advantage by utilizing our application engineering know-how, extensive training, and 24-hour technical support from anywhere in the USA. Through our commitment to flexible manufacturing, Omron has become a leader in the manufacture of Sensors, Digital Panel Meters, Digital Displays, Counters, Timers, PLCs, Process and Temperature Controllers, and other control devices. Technical Information FAST More I/O Points C200HS C200Hα Quality Recognized Industry-Wide 2 expansion backplanes max. 3 expansion backplanes max. Obtain up-to-date technical specifications for all Omron products 24 hours a day, 7 days a week from your fax machine. Call our ControlFax at 847.843.1963. Request #50 for a directory of all documents available. Information is also available on the internet. Visit our web site at http://oei.omron.com and get the latest information on Omron products and literature. Worldwide Sales and Support Network You’ll find over 200 stocking distributors and local sales offices across the United States. With distributors in Canada and Mexico, and branch offices worldwide, Omron provides replacement components, service and multilingual documentation virtually anywhere in the world. Expertise You Can Rely On You can rely on the high quality PLC products you’ve come to expect from Omron. Trust our nationwide network of local stocking distributors and system integrators to offer expertise you can depend on. Just give us a call. TABLE OF CONTENTS SECTION PAGE NUMBER SYSTEM COMPONENTS 1 System Overview Introduction 2 Overview 6 PLC System specifications 8 CPU Features 9 Selection Guide 10 Specifications and Characteristics 11 Communication Boards 14 Protocol Macro Function 15 Memory Cassettes 17 Power Supply Modules 18 Backplanes 19 Connecting I/O Cables 21 Discrete I/O Modules 22 Special I/O Modules 26 COMMUNICATIONS Overview Communication Modules Fiber-optic Cable and Connections 69 70 72 89 PROGRAMMING Programming Software SSS and SYSWIN Protocol Support Software Programming Peripherals and Cables Programming Instructions 91 92 94 97 99 STANDARD PARTS 123 COMPLEMENTARY 141 PRODUCTS Operator Interface Terminals PART NUMBER INDEX 142 149 NOTE: Specifications to change without notice. Warranty: Omron certifies all of its products either meet or exceed stipulated specifications. Omron is not liable for stenographic and/or clerical errors. Omron's obligation under this warranty is limited solely to repair or replacement at Omron's discretion. Omron will not be liable for any design furnished by Buyer and incorporated into equipment. This warranty is voided if the product is altered in any way or suffers consequential damage due to negligence or misuse. Omron is not to suffer risk due to the suitability or unsuitability or the results of the use of its products used in combination with any electrical or electronic components, circuits, systems assemblies or any other materials or substances or environments. The foregoing warning is the only warranty which Omron Electronics, Inc., provides with respect to the products listed herein. No other warranties, expressed, implied, or statutory shall apply, whether as to merchantability, fitness for a particular purpose, description, or otherwise. Limitation of Liability: Notwithstanding any other statement herein, Omron Electronics, Inc., its contractors and suppliers, shall not be liable for any special, indirect, incidental or consequential damages. The remedies of the purchaser set forth herein are exclusive where so stated and the total cumulative liability of Omron Electronics, Inc., its contractors and suppliers, with respect to this contract or anything done in connection therewith, shall not exceed replacement price reimbursement as to the product on which such liability is based. SYSTEM COMPONENTS SYSTEM COMPONENTS System Overview Introduction Overview PLC System specifications CPU Features Selection Guide Specifications and Characteristics Communication Boards Protocol Macro Function Memory Cassettes Power Supply Modules Backplanes Connecting I/O Cables Discrete I/O Modules Special I/O Modules 1 2 6 8 9 10 11 14 15 17 18 19 21 22 26 1 SYSTEM COMPONENTS The New C200Hα Series: Powerful Mid-Sized Machine Control, Powerful Onsite Data Processing Migrate Easily While the functions and capabilities of the C200Hα series have been dramatically enhanced, common languages and I/O units allow smooth migration from C200H/HS PLCs. Improved Special I/O Modules The maximum number of Special I/O Modules that can be mounted on the CPU has been increased from 10 to 16 modules. You can easily manage a control system with the right combination of Special I/O Modules. The intelligent I/O read and intelligent I/O write instructions can be executed to transfer more than one word of data. All of the C200HS Special I/O Modules can be used without any modification. In addition, a PC Card Module, Motion Control Module, and Two-axis High-speed Counter Module have been added. A Built-in Protocol Macro Function Previously, it was necessary to write a communications program for the ASCII Module or BASIC Module whenever a measurement device or component was connected to the PLC. The C200H Alpha PLCs are equipped with the Protocol Macro Function which incorporates these communications programs into the ladder program with just a few ladder instructions. A variety of workplace data can be processed in real-time improving quality and reducing total product cost. System development time can be reduced substantially. 2 Interface to Memory or Ethernet via PC Card Module The PC Card Module provides two PCMCIA interface slots. Either two type I or II or one type III PC card can be installed. The system accepts SRAM, FLASH and ATA cards. PC File Operations: C200HX/HG/HE memory contents may be written to memory cards as files using ladderdiagram instructions. File contents can be compared and searched and word data can be separated by commas in the file format so that commercially available spreadsheets may be used. Ethernet Connection: Using an Ethernet PCMCIA card, data may be exchanged using Omron’s FINS protocol via UDP/IP. SYSTEM COMPONENTS Build Networks Easily with the Alpha’s Built-in Features. Using built-in Host Link function of the C200H Apha, connect directly to operator interface terminals using a cable as an interface, or use a One-to One data links between alpha PLCs are just as easy to make. When networking with a PC, the TXD and RXD instructions can be used to carry out RS-232C communications from the PLC, and the STUP instruction can be used to switch between Host Link and RS-232C, communications. Open up Your Communications Possibilities in All Three Automation Network Levels DEVICE LEVEL NETWORKS: The new C200HW-DRM21 Module supports DeviceNet open multi-vendor network communications. DeviceNet makes it possible to connect devices that have a wide variety of parameters or data, such as inverters or analog devices. It also allows other DeviceNet products to be connected as well. CONTROL LEVEL NETWORKS: Omron's SYSMAC Link and SYSMAC Net networks provide high-speed real-time data transfer. SYSMAC Link’s data link capacity has been increased from 918 words to 2,966 words. Connect to a Variety of Serial Devices The C200Hα CPU's can be equipped with one of six communication boards. By installing the appropriate communication board, the CPU can communicate with SYSMAC Link / SYSMAC Net modules, a PC Card module or serial devices. Using the Protocol Macro Function built into the C200HW-COM04-E, C200HW-COM05-E or C200HW-COM06-E communications boards, communications sequences for one of seven types of installed Omron protocols may be used or customized for a modem, operator interface, bar code reader, temperature controller, or any kind of RS-232C, RS-422 or RS-485 device. INFORMATION LEVEL NETWORKS: The C200HW-PCS01 PCMCIA Module allows data exchange with CV Ethernet units, PCs and workstations using Omron’s FINS protocol via Ethernet UDP/IP. 3 SYSTEM COMPONENTS BUILD YOUR OWN CONTROL AND DATA PROCESSING SYSTEM CPU RACK CPU Choose from 11 CPU models p.19 CPU BACKPLANE C200HW-BC031 C200HW-BC051 C200HW-BC081 C200HW-BC101 Separate CPU and power supply CPU and Expansion Backplanes CPU and power supply mount on a dedicated CPU backplanes Local expansion may be done with the new space-saving C200Hα expansion backplanes or current C200H backplanes Connect up to 5 remote I/O backplanes Special I/O Take full advantage of the C200Hα’s power with any combination of 20 Special I/O Modules p.17 p.9 EEPROM MEMORY CASSETTES 4K words C200HW-ME04K 8K words C200HW-ME08K 16K words C200HW-ME16K 32K words C200HW-ME32K EPROM MEMORY CASSETTES 16/32K words C200HS-MP16K CPUs C200HE-CPU11-E C200HE-CPU32-E C200HE-CPU42-E C200HG-CPU33-E C200HG-CPU43-E C200HG-CPU53-E C200HG-CPU63-E C200HX-CPU34-E C200HX-CPU44-E C200HX-CPU54-E C200HX-CPU64-E p.18 POWER SUPPLY MODULE C200HW-PA204 C200HW-PA204S C200HW-PD024 EXPANSION I/O RACK Communications All CPUs include a multifunctional peripheral port to communicate to programming peripherals Standard Host Link port is built into selected CPUs One of six communications boards can also be installed in the CPU. When used with the protocol macro function, these boards provide a simple way to connect with a SYSMAC Link or SYSMAC Net Link module, to communicate with a Modem, operator interface, bar code reader, Process Controller or any kind of RS-232C, RS-422 or RS485 device. p.21 p.18 p.19 I/O CONNECTING CABLE C200H-CN❏❏1 (30cm,70cm,2m,5m,10m) POWER SUPPLY MODULE C200HW-PA204 C200HW-PA204S C200HW-PD024 EXPANSION 1/O BACKPLANE C200HW-BI031 C200HW-BI051 C200HW-BI081 C200HW-BI101 SLAVE RACKS Software Support Supported by both SYSMAC Support Software Version 1.2 or greater and SYSWIN version 3.0 or greater 4 p.84 p.20 REMOTE I/O SLAVE MODULE Fiber-optic, 100/200 VAC C200H-RT001-P Fiber-optic, 24 VDC C200H-RT002-P Wired, 100/200 VAC C200H-RT201 Wired, 24 VDC C200H-RT202 SLAVE I/O BACKPLANE C200H-BC031-V2 C200H-BC051-V2 C200H-BC081-V2 C200H-BC101-V2 SYSTEM COMPONENTS COMMUNICATIONS BOARDS p.14 p.14 C200HW-COM01 C200HW-COM02 (cannot be mounted to the CPUHE-CPU11-E) p.14 p.14 C200HW-COM03 C200HW-COM04-E p.14 p.14 C200HW-COM05-E C200HW-COM06-E COMMUNICATIONS MODULES p.81 DEVICENET SCANNER C200HW-DRM21 p.85 p.87 HOST LINK RS422 C200H-LK202-V1 Fiber-optic C200H-LK101-PV1 RS232 C200H-RM201-V1 p.72 PC LINK C200H-LK401 p.83 PC CARD* C200HW-PCU01 Ethernet Set* C200HW-PCS01-E REMOTE I/O MASTER Fiber-optic C200H-RM001-V1 Wired C200H-RM201-V1 p.78 SYSMAC LINK* Coaxial C200HW-SLK23/24 Fiber-optic C200HW-SLK13/14 p.75 SYSMAC NET LINK* C200HS-SNT32 *Use these modules together with communications boards (C200H-COM01/04-E) in the CPU Rack. SPECIAL I/O MODULES p.40 p.41 p.62 p.60 p.51 p.58 p.66 ANALOG INPUT C200H-AD001 C200H-AD002 ANALOG OUTPUT C200H-DA001 C200H-DA002 ASCII/BASIC C200H-ASC02 CAM POSITIONER C200H-CP114 FUZZY LOGIC C200H-FZ001 HIGH-SPEED COUNTER C200H-CT❏❏❏ RFID SENSOR C200H-IDS❏❏ p.53 p.48 p.56 p.42 p.44,46 DUAL-AXIS MOTION CONTROL C200H-MC221 PID CONTROL C200H-PID0❏ POSITION CONTROL C200H-NC211 C200H-NC112 TEMPERATURE SENSOR C200H-TS❏❏❏ TEMPERATURE CONTROL C200H-TC❏❏❏ C200H-TV❏❏❏ p.26 p.64 VOICE C200H-OV001 B7A INTERFACE 16 points C200H-B7A❏1 p.26 p.29,34 p.30,36 p.31 p.38 p.32 B7A INTERFACE 32 points/64 points C200H-B7A❏❏ HIGH DENSITY INPUT C200H-ID❏❏❏ Group 2 C200H-ID21❏ HIGH DENSITY OUTPUT C200H-OD❏❏❏ Group 2 C200H-OD21❏ ANALOG TIMER C200H-TM001 MIXED I/O 16 inputs/16 outputs C200H-MD❏❏❏ INTERRUPT INPUT C200HS-INT01 (CPU Backplane ONLY) (cannot be used on Slave rack) DISCRETE I/O MODULES p.22 p.22 p.22 p.22 8 POINT INPUT C200H-I❏❏❏❏ 16/32 POINT INPUT C200H-I❏❏❏❏ 5/8/16 POINT OUTPUT C200H-O❏❏❏❏ 12/32 POINT OUTPUT C200H-O❏❏❏❏ 5  SYSTEM OVERVIEW BASIC CONFIGURATION -- C200HX/HG/HE CPU Rack I/O Connecting Cable Backplane I/O Modules Special I/O Modules Communication Modules CPU Power Supply Module NOTE: Memory Cassette Communications Board SELECT THE APPROPRIATE BACKPLANE FOR THE CPU RACK, EXPANSION I/O RACK, AND SLAVE RACK. EACH TYPE OF BACKPLANE IS A DIFFERENT MODEL. For blackplane dimensions, refer to the Backplanes subsection found later in this section. To order, refer to the specific information provided separately in the Standard Parts section of this catalog. CPU Rack The CPU Rack is the master controller rack for the control systems and contains the system communications ports. It may be expanded using Expansion Racks and Slave Racks. A fully configured C200Hα CPU Rack includes a CPU, Backplane, Power Supply Module, I/O Modules, Special I/O Modules and Communication Modules, as appropriate for the application. A complete system may also include connecting cables and programming software or hardware. A total of two SYSMAC LINK or SYSMAC NET Link Modules can be mounted to the CPU if the C200HW-COM01 or C200HWCOM04-E Communications Board is connected to the CPU. Only two C200HS-INT01 Interrupt Input Modules can be mounted on a CPU Rack. 6  SYSTEM OVERVIEW BASIC CONFIGURATION -- C200HX/HG/HE Slave Racks Expansion I/O Racks Backplane I/O Modules Special I/O Modules Communication Modules Fiber-optic cable or twisted-pair cable I/O Modules and Special I/O Modules Power Supply Module Remote I/O Slave Module Local Expansion Racks Slave Racks The configuration of an Expansion I/O Rack includes a Power Supply Module, an Expansion Backplane, and appropriate I/O Modules, Special I/O Modules, and Communication Modules. The number of allowable Expansion Racks varies with CPU model. Up to three Expansion I/O Racks can be connected to the C200HX-CPU54-E, C200HX-CPU64-E, C200HGCPU53-E, or C200HG-CPU63-E. Up to two Expansion I/O Racks can be connected to any other CPU for the C200HX, C200HG, and C200HE. Different types of Backplanes are necessary for the CPU, Expansion I/O Rack, and the Slave Rack. To expand a system and minimize wiring costs, you may connect a maximum of five Slave Racks per system. The Configuration of a Slave Rack includes a Remote I/O Slave Module, a Backplane (for the C200HX/HG/HE Slave Rack), I/O Modules, and Special I/O Modules. To mount a High-density I/O Module to a Slave Rack, use a C200H-RM001-PV1/RM201. Note: C200H-RM001-P Master Modules cannot be used. Group-2 High-density I/O Modules, Communications I/O Modules, and Interrupt Input Modules cannot be mounted in Slave Racks. You can connect a Maximum of two Expansion I/O Racks to Slave Racks using I/O Connecting Cable. Always count the Expansion I/O Racks (connected in this way) against the maximum of five Slave Racks that can be connected. 7  SYSTEM OVERVIEW C200HX/HG/HE SPECIFICATIONS C200Hα PLC -- System Specifications ITEM SPECIFICATIONS Supply voltage AC power supply: 100 to 120/200 to 240 VAC selectable 50/60 Hz DC power supply: 24 VDC Operating voltage range AC power supply: 85 to 132/170 to 264 VAC DC power supply: 19.2 to 28.8 VDC Power consumption AC power supply: 120 VA max. DC power supply: 50 W max. Surge current 30 A max. Output capacity 4.6 A, 5 VDC; 0.6 A, 26 VDC; 0.8 A, 24 VDC+10%/--20% (C200HW-PA204S only) Insulation resistance 20 MΩ between AC terminals and the GR terminal at 500 VDC (see note 1) Dielectric strength 2,300 VAC at 50/60 Hz for 1 minute between AC terminals and housing; 1,000 VAC at 50/60 Hz for 1 minute between DC terminals and housing. Leakage current: 10 mA max. (see note 1) Noise immunity 1,500 Vp-p, pulse width: 100 ns to 1 µs, rise time: 1 ns pulse (by noise simulator) Vibration 10 to 57 Hz; 0.075 mm amplitude, 57 to 150 Hz; acceleration: 1 G, in X, Y, and Z directions, for 80 minutes each (sweep time 8 min x 10 sweeps = 80 min); (When mounted on DIN track, 2 to 55 Hz, 0.3 G, in X, Y, and Z directions for 20 minutes each) Shock 15G (147 m/s2) in X, Y, and Z directions, 3 times each Ambient temperature Operating: 0 to 55°C (32°to 131.0°F) Storage: --20 to 75°C (-4.0 to 167.0°F) without battery Humidity 10% to 90% (without condensation) Atmosphere Must be free of corrosive gases Grounding Less than 100 Ω Enclosure rating IEC IP30 (mounted in a panel) Weight 6 kg max. (CPU: 315 g max., Power Supply Module: 510 g max., Backplane: 445 g to 1040 g) Note: 8 Be sure to disconnect the LG and GR terminals when conducting insulation resistance tests or dielectric strength tests. Internal components might be damaged if insulation resistance tests are repeated many times with the LG and GR terminals connected.  CPU YOUR INTRODUCTION TO THE C200HX/HG/HE CPU Features LED Indicators Select from Eleven C200Hα CPUs within Alpha’s Three Basic Model Types SYSMAC C200HX Programmable Controller CPU64 Each model has different program capacities, processing speeds, I/O capabilities, communications connections and features. (The C200Hα CPU Selection Table is provided later in this section.) Memory cassette DIP switch Optional Back-up Memory Cassettes Multifunctional Peripheral port For program back-up or rewrite option, each CPU has a special Memory Cassette compartment. Multifunctional Peripheral Port Directly connect to programming peripherals or communicate to Omron’s Operator Interface Terminals and other third party devices using an optional CIF Convertor Cable. RS-232C port Built-in RS-232C Port Direct Host Link communications to the CPU or interface with other devices through serial communications. Available on selected models only. Versatile Communications Install one of six C200Hα Communications Boards to have additional communications ports. The boards fit into the communications slot in the CPU and enable communication with SYSMAC LINK or SYSMAC NET modules, a PC card module or a variety of serial devices -- including Operator Interfaces. Order the Communications Board and Memory Cassette separately (not provided with the CPU). Communications Board (C200HW-COM06-E shown here) Indicators INDICATOR ON THE CPU FUNCTION RUN (green) Lit when the PLC is operating normally. ERR (red) Flashes if the PLC in operation detects any non-fatal error. (The PLC will continue operating.) Lit if the PLC in operation detects any fatal error. (The PLC will stop operating. ) After the PLC stops operating, the RUN indicator will be off, and all output signals of the Output Modules will be interrupted. INH (orange) Lit when the Load OFF flag (AR bit) is ON. (All output signals of the Output Modules will be interrupted.) COMM (orange) Flashes when the CPU is communicating with the device connected to the peripheral port or RS-232C port. Protocol Macro Three C200Hα Communications Boards offer the Protocol Macro Instruction that controls data transfer with various communications devices and components equipped with RS-232C or RS-422/-485 ports. With the Protocol Macro Function built into the C200HW-COM04, C200HW-COM05-E and C200HWCOM06-E Communications Boards, communications sequences (data transfer procedures) may be modified with Omron’s Protocol Support Software. Although seven Omron Communications sequences are built-in, you can use the Protocol Support Software to create other communications sequences. For more details, refer to the Communication Board section that follows. 9  CPU C200HX/HG/HE CPU SELECTION GUIDE Consider these Application Needs when Selecting the C200Hα CPU 1. What is the required program capacity? 2. Determine total standard I/O (with expansion rack) and Special I/O requirements. 3. What communications interfaces are required? C200Hα CPU Selection Table PROGRAM CAPACITY (WORDS) DM (WORDS) 3.2K 4K 7.2K 6K EM (WORDS) None BASIC INSTRUCTION PROCESSING TIME 0.3 µs min. NO. I/O PTS. 640 MAX. NO. EXPANSION I/O RACKS) 2 880 MAX. NO. HIGHDENSITY I/O MODULES (GROUP 2) MAX. NO. OF SPECIAL I/O MODULES (GROUP 1) NO. BELOW = TOTAL NO. OF MODULES NO. = TOTAL NO. OF MODULES Unavailable 10 RS-232C CLOCK FUNCTION COMMUNICATIONS BOARD AVAILABLE PART NUMBER No No No C200HE-CPU11-E Yes Yes C200HE-CPU32-E Yes Yes 10 Yes 15.2K 6K 6K 0.15 µs min. 880 1,184 31.2K 6K 6K x 3 (18K) 0.1 µs min. 880 1,184 Note: 10 2 3 2 3 10 10 No C200HG-CPU43-E C200HG-CPU53-E 16 (10) See Note No 10 10 No 16 (10) S N See Note t C200HG-CPU33-E Yes 16 (10) See Note 16 (10) S N See Note t C200HE-CPU42-E Yes C200HG-CPU63-E Yes Yes C200HX-CPU34-E Yes C200HX-CPU44-E No C200HX-CPU54-E Yes C200HX-CPU64-E When the table indicates a selection total of 16 High-density I/O Modules or Special I/O Modules -- the total of 16 is applicable only if you select from the Modules in this list: • High-density I/O Modules: C200H-ID216 (32 inputs) and C200H-OD218 (32 outputs). • Special I/O Modules: C200H-AD002, C200H-DA002, C200H-NC211, and C200H-CT021 If your selections are not in the list above: you may be limited to only 10 modules -- as indicated in the table. An exception: A total of only 8 can be used if you select C200H-OD219, C200H-ID217, or C200H-ID111 High-density I/O Modules.  CPU SPECIFICATIONS, CHARACTERISTICS C200Hα CPU Characteristics ITEM SPECIFICATIONS Control method Stored program I/O control method Cyclic scan with direct output and immediate interrupt processing are both possible. Programming method Ladder diagram Instruction length 1 address/instruction, 1 to 4 words/instruction Number of instructions 14 basic instructions, 231 special instructions Execution time Basic instructions: e.g., LD Special instructions: e.g., MOV(21) Program capacity -E:0.3 µs -E:0.15 µs -E:0.1 µs C200HE-CPU C200HG-CPU C200HX-CPU -E:1.2 µs -E:0.6 µs -E:0.4 µs C200HE-CPU C200HG-CPU C200HX-CPU C200HE-CPU11-E: 3.2K words max. C200HE-CPU32-E/CPU42-E: 7.2K words max. C200HG-CPU -E: 15.2K words max. C200HX-CPU -E: 31.2K words max.   I/O bits 640 (00000 to 02915, 30000 to 30915) IR bits 6,464 (03000 to 23115, 31000 to 51115) SR bits 1,080 (23200 to 25507, 25600 to 29915) TR bits 8 (TR 0 to 7) HR bits 1,600 (HR 0000 to 9915) AR bits 448 (AR 0000 to 2715) LR bits 1,024 (LR 0000 to 6315) Timers/Counters 512 (TIM/CNT 000 to 511) DM words Read/Write: 6,144 (DM 0000 to 6143) Read-only: 512 (DM 6144 to 6655) Expansion: Up to 3,000 words max. (DM 7000 to 9999) EM words Read/Write: C200HE-CPU C200HG-CPU C200HX-CPU Power failure backup function Holds HR, AR, CNT, DM, and EM and clock (RTC) contents. Memory backup time The battery service life is five years at 25°C (77°F). The service life will be shortened if the battery is used at higher temperatures. Replace the battery within one week after the battery alarm indicator starts flashing. When replacing the battery, install the new battery within five minutes after removing the old one. Self-diagnostic function CPU errors (watchdog timer), I/O verification errors, host link errors, memory errors, battery errors, I/O bus errors, remote I/O errors, etc. Program check function Checks the program from the time the program starts running and checks the omission of the END instruction or any other improper instruction. This function allows three-level checking of programs through the Programming Console. -E: None -E: 6,144 (EM 0000 to EM 6143) -E: 6,144  3 banks (EM 0000 to EM 6143) 11  CPU SPECIFICATIONS, CHARACTERISTICS Comparing C200Hα CPU Specifications Use the following table to compare the functions of the C200HX, C200HG, and C200HE with those of the C200HS and C200H. FUNCTION C200HX/HG/HE C200HS C200H User Memory (UM) 3.2K words (C200HE-CPU11-E) 7.2K words (C200HE-CPU 2-E) 15.2K words (C200HG-CPU 3-E) 31.2K words (C200HX-CPU 4-E) 15.2K words 3.2K words/7.2K words Normal Data Memory (DM) C200HX/G: 6,144 words (DM 0000 to DM 6143) (DM 4000 to DM 5999 do not exist in the C200HECPU11-E) C200HE-CPU16: 4000 words (DM0000-3999) 6,144 words (DM 0000 to DM 6143) 1,000 words (DM 0000 to DM 0999) Fixed Data Memory 512 words (DM 6144 to DM 6655) 512 words (DM 6144 to DM 6655) 1,000 words (DM 1000 to DM 1999) Fixed Expansion Data Memory 0 to 3,000 words (DM 7000 to DM 9999) 0 to 3,000 words (DM 7000 to DM 9999) None Extended Data Memory (EM) C200HE: C200HG: C200HX: None None Expansion Racks 3 max. (2 max. for C200HE-CPU CPU-3 -E/4 -E) 2 max. 2 max. Group-2 High-density I/O Modules 0 to 9 and A to F Modules per PLC C200HE-CPU11-E: No Group-2 Modules connected C200HE-CPU 2-E, C200HG/HX-CPU-3 -E/CPU4 -E: 0 to 9 Units per PLC 0 to 9 Modules per PLC 0 to 9 Modules per PLC Special I/O Modules 0 to 9 and A to F Modules per PLC C200HE-CPU -E, C200HG/HX-CPU-3 -E/CPU4 -E: 0 to 9 Modules per PLC 0 to 9 Modules per PLC 0 to 9 Modules per PLC Basic instructions (LD) 0.1 µs (C200HX) 0.15 µs (C200HG) 0.3 µs (C200HE) 0.375 µs 0.75 µs Special instructions (MOV) 0.4 µs (C200HX) 0.6 µs (C200HG) 1.2 µs (C200HE) 19 µs 88 µs Other special instructions C200HX and C200HG: Approx. 1/3 to 2/3 of the time required by the C200HS. C200HE: Approx. 3/4 to 4/5 of the time required by the C200HS. --- --- END processing time 0.7 ms (C200HX/HE-CPU 2-E) 2.1 ms (C200HE-CPU11-E) 0.7 ms 2.8 to 3.5 ms RS-232C port C200HX/HG/HE-CPU2 -E/4 -E/6 -E C200HS-CPU2 -E/3 -E None Clock function All models except the C200HE-CPU11-E. All models Incorporated by the Memory Module SYSMAC LINK Module and SYSMAC NET Link Module connection C200HW-COM01 and C200HW-COM04-E Communications Boards available for connection except the C200HECPU11-E. C200HS-CPU3 -E C200H-CPU11-E/31-E Communications Board The Communications Board can be mounted to all CPUs except the C200HE-CPU11-E. The following are possible with the Communications Board: Use of the SYSMAC LINK Module and SYSMAC NET Link Module expansion of up to 2 communications ports, and use of a protocol macro function None None Interrupts Interrupt Input Modules 2 (16 points) 1 (8 points) None Interruption with Communications Board Possible --- --- Response time Same as the C200HS. 1 ms if the C200HW-SLK C200H-compatible mode: 10 ms C200H mode: 1 ms The C200HS in any mode connected to the SYSMAC LINK Module or SYSMAC NET Link Module 10 ms --- Service time 3.5 ms max. (1 system) 10.8 ms max. (1 system) 11.5 ms max. (1 system) Remote programming Via the peripheral port, RS-232C port, and Communications Board Via the peripheral port only --- Influence on interrupt response performance None 10 ms is required by the C200HS in any mode. --- Memory I/O Execution time CPU SYSMAC LINK 12    No EM 6,144 words x 1 bank 6,144 words x 3 banks  -E and C200HG/HX-             is used.     CPU SPECIFICATIONS, CHARACTERISTICS User Memory Area The C200HX, C200HG, and C200HE have a User Memory (UM) area allocation function. This function allows the use of the ladder program area of the UM as a fixed expansion DM area and I/O comment area. The function is enabled with the SYSMAC Support Software (SSS), SYSWIN, or the Programming Console. Only SSS can be used to designate any part of the ladder program area as an I/O comment area (i.e., the Programming Console cannot be used to designate any part of the ladder program area as an I/O comment area. Error log area PLC Setup area System reserved area DM 9999 DM 7000 DM 6655 Fixed DM (512 words) Normal Data Memory (DM) 6,144 words Special I/O Module default area DM 6600 DM 6144 DM 6000 DM 2599 DM 1000 DM 0000 C200HX/HG/HE Memory Area Structure Fixed expansion DM area (0 to 3,000 words) I/O comment area Ladder program area Possible ROM area Built-in UM (32K words max.) Ladder program area A user program is stored in the ladder program area. If part of the UM is used as a fixed expansion DM area or I/O comment area, the capacity of the ladder program area storing the user program will be reduced accordingly. I/O comment area I/O comments are stored in the I/O comment area. The I/O comments can be stored with a program. The I/O comments can be monitored without loading the comment, just as with conventional comments. Fixed expansion DM area The default values of the Special I/O Module, Programmable Terminal, the character string of the Programmable Terminal, and operation data are stored in the fixed expansion DM area. By changing the I/O monitor present value of the Programming Console or using the DM edit transfer operation of the Ladder Support Software, the default values can be written to DM 7000 to DM 9999. System reserved area The system reserved area is used by the system only. PLC Setup area The settings required for the operation of the PLC are stored in the PLC Setup area. Normal DM area The user can freely use the normal DM as a data area for arithmetic operations. If the Special I/O Module is used, DM 1000 to DM 2599 will be a Special I/O Module default area. • DM 1000 to DM 2599 can be used as a normal DM if DM 7000 to DM 8599 are set as a Special I/O Module default area with the PLC Setup. DM 6000 to DM 6030 are used exclusively as an error log area. • Unlike the normal DM area, nothing can be written to the fixed expansion DM area using ladder programming. • The capacity of a ladder program will decrease if the size of the fixed expansion DM area and the total capacity of the I/O comments increase. • The C200HX, C200HG, and C200HE do not have a fixed expansion DM area or I/O comment area before shipping. The user must allocate these areas in the UM according to the application. 13  COMMUNICATIONS BOARDS SPECIFICATIONS, SELECTION GUIDE Indicators Indicators Bus connector The C200Hα offers the industry’s most versatile PLC communications options. With six Communications Board options, you can select just the right communications for your application. The boards fit into the communications slot in the CPU and let you expand the PLC functionality by connecting to other PLCs or computers with Omron’s SYSMAC LINK, SYSMAC NET or, a PC Card Module. A variety of serial ports let you connect to Operator Interfaces, PCs, or other serial communication devices. Port A (RS-232C) C200HW-COM01 C200HW-COM02 Specifications Indicators Indicators Bus connector Port A (RS-422/485) C200HW-COM03 Port A (RS-232C) PART NUMBER DESCRIPTION C200HW-COM01 CPU connection when using SYSMAC LINK or SYSMAC NET Link Communications Modules C200HW-COM02 One RS-232C port C200HW-COM03 One RS-422/485 port C200HW-COM04-E CPU connection for the SYSMAC LINK Module or SYSMAC NET Link Module, and an RS-232C port, with a protocol macro function C200HW-COM05-E Two RS-232C ports with a protocol macro function C200HW-COM06-E One RS-422/485 port, and one RS-232C port, with a protocol macro function C200HW-COM04-E Communications Board Indicators Indicators INDICATOR COLOR STATUS MEANING FUNCTION RDY Green Not lit Board not ready for use Hardware error Flashes Setting error System setting or protocol data error Lit Board ready for use Normal operation Flashes Communicating Port B is in use for communication Indicators Port B (RS-232C) Port B (RS-232C) Port A (RS-232C) Port A (RS-422/485) COMB C200HW-COM05-E Note: C200HW-COM06-E Order the Communications Board and Memory Cassette separately (not provided with the CPU). Memory Cassette CPU Communications Board 14 COMA Orange Port A is in use for communication  COMMUNICATION BOARDS PROTOCOL MACRO The Protocol Macro instruction permits easy interfacing of C200Hα CPUs with peripheral devices. In cases where ASCII/BASIC Modules have been used to interface with peripheral devices, the Protocol Macro instruction now offers an extremely automated method. The Protocol Macro instruction is a communications protocol that controls data transfer using various devices and components equipped with RS-232C or RS-422/485 ports -- thus, replacing ASCII/BASIC Modules and the difficult associated programming procedures. The C200Hα Communications Boards COM04-E, COM05-E, and COM06-E have a built-in Protocol Macro capability, providing seven Omron communications protocols. The data transfer procedures may be modified with Omron’s Protocol Support Software. Communications sequences are executed from the ladder program with the Protocol Macro Instruction (PMCR). IBM PC/AT or Compatible C200HW-ZW3AT1-E Protocol Support Software: The Protocol Macro software is used to set or customize protocol macro data. Features The C200Hα Communications Boards COM04-E, COM05-E, and COM06-E (with protocol macro capability built-in) offer these seven standard communications sequences: 1. Temperature Controller Sequence E5 J, E5 K, ES100 , and E5ZE 2. Intelligent Signal Processor Sequence K3TH, K3TR, K3TX, and K3TC 3. Bar Code Reader Sequence V500 and V520 4. Laser Micrometer Sequence 3Z4L 5. Visual Inspection System Sequence F200, F300, and F350 6. ID Controller Sequence V600 7. Hayes AT Command (Modem) Sequence ME 1414BZ, MD 24FB10V, and MD 144FB5V Or, use the Protocol Support Software to create Communications sequences other than those listed.    Standard measuring devices, components, and personal computers C200HX/HG/HE C200HW-COM04-E/05-E/06-E Communications Board (with protocol macro function) RS-232C Asynchronous (start-stop synchronization) communication OMRON’s peripheral devices (equipped with standard communications sequences) Visual Inspection System Intelligent Signal Processor Modem ID Controller Temperature Controller Bar code reader 15  COMMUNICATION BOARDS PROTOCOL MACRO System Configuration Examples C200HX/HG/HE RS-232C (C200HW-COM05-E) An RS-232C line connects the C200HW-COM05-E and a device, allowing the RS-232C line to be a maximum of 15 m. 15 m RS-232C port B RS-232C RS-232C port A RS-422/485 (C200HW-COM06-E) The C200HW-COM06-E connects to one or more devices through the RS-422 and RS-485 port provided the RS-422 or RS-485 line between the C200HW-COM06-E and the farthest device is a maximum of 500 m. C200HX/HG/HE 15 m RS-422/485 port A RS-232C port B RS-422/485 Temperature Controller Temperature Controller (With an RS-422 and RS-485 communications function) Temperature Controller Temperature Controller Temperature Controller 500 m 16 Simple communications sequence Device with RS-232C interface  MEMORY CASSETTES SPECIFICATIONS EEPROM or EPROM Memory Cassettes Each C200Hα CPU can accept a Memory Cassette to provide back-up or downloading of programs and data. EEPROM models allow the program to be downloaded to and from the CPU memory. EPROM models allow the user to write to an EPROM and insert it into the memory cassette. EEPROM Memory Cassette -No Back-up Power Supply Required The EEPROM Memory Cassette can be installed in the C200HX, C200HG, and C200HE CPUs to write and read programs and I/O data to the CPU. Because the EEPROM Memory Cassette does not require any backup power supply, it will retain its data even after it is disconnected from the CPU. EEPROM Memory Cassette EEPROM Memory Cassette Capacity CAPACITY PART NUMBER 4K words C200HW-ME04K 8K words C200HW-ME08K 16K words C200HW-ME16K 32K words C200HW-ME32K EPROM Memory Cassette -Use a Standard PROM Writer to Write a Program Connect an EPROM to the EPROM Memory Cassette before installing the EPROM Memory Cassette into the CPU. An EPROM Memory Cassette will lose its data if it is disconnected from the CPU. EPROM Memory Cassette Capacity DESCRIPTION CAPACITY PART NUMBER Cassette 16K words/32K words C200HS-MP16K EPROM (Order ROM Separately) S t l ) Equivalent to 27256 ROM-JD-B Equivalent to 27512 ROM-KD-B EPROM Memory Cassette 17  POWER SUPPLY MODULES CAPACITIES AND SPECIFICATIONS All CPU Racks and Expansion Racks feature separate Power Supplies that may be replaced individually to meet system requirements without having to replace the other components. The Power Supply provides power for the CPU and Modules on the Rack. Choose an AC or DC version. Model C200HW-PA204S comes with built-in 24 VDC Power Supply that may be used to power Special I/O Modules, Sensors, or other devices, eliminating the need for a separate Power Supply. C200HW-P 18 Power Supply Modules Available SUPPLY VOLTAGE COMMENTS PART NUMBER 100 to 120 VAC 200 tto 240 VAC --- C200HW-PA204 With 24-VDC service power supply C200HW-PA204S 24 VDC --- C200HW-PD024  BACKPLANES SPECIFICATIONS Select the Appropriate Backplane for the CPU with its I/O Modules When selecting Backplanes for the CPU, the Expansion I/O, and the Slave Rack(s), each type of Backplane is a different model number. To order, refer to the specific information provided separately in the Standard Parts section of this catalog. Dimensions CPU I/O Backplane C200HW-BC  Unit: mm (inch) 130 118 (5.12) (4.65) 130 (5.12) W1 W2 118 (4.65) NO. OF SLOTS W1 W2 PART NUMBER 3 slots 246 (9.69) 260 (10.24) C200HW-BC031 5 slots 316 (12.44) 330 (12.99) C200HW-BC051 8 slots 421 (16.57) 435 (17.13) C200HW-BC081 10 slots 491 (19.33) 505 (19.88) C200HW-BC101 Expansion I/O Backplane C200HW-BI  Unit: mm (inch) 118 (4.65) 130 (5.12) 130 (5.12) W1 W2 118 (4.65) NO. OF SLOTS W1 W2 PART NUMBER 3 slots 175 (6.89) 189 (7.44) C200HW-BI031 5 slots 245 (9.65) 259 (10.20) C200HW-BI051 8 slots 350 (13.78) 364 (14.33) C200HW-BI081 10 slots 420 (16.54) 434 (17.09) C200HW-BI101 19  BACKPLANES SPECIFICATIONS Slave Rack Backplane C200H-BC -V2  Unit: mm (inch) 130 118 (5.12) (4.65) 130 (5.12) W1 W2 20 118 (4.65) NO. OF SLOTS W1 W2 PART NUMBER 3 slots 246 (9.69) 260 (10.24) C200H-BC031-V2 5 slots 316 (12.44) 330 (12.99) C200H-BC051-V2 8 slots 421 (16.57) 435 (17.13) C200H-BC081-V2 10 slots 491 (19.33) 505 (19.88) C200H-BC101-V2  CONNECTING I/O CABLES FEATURES, CAPACITIES AND SPECIFICATIONS I/O Connecting Cables connect a CPU Rack to an Expansion I/O Rack or an Expansion I/O Rack to another Expansion I/O Rack. The following five types of I/O Connecting Cables are available. The total length of the I/O Connecting Cables used in a configuration must be 12 m maximum. Note: Count the Expansion I/O Racks (connected in this way) against the maximum of five Slave Racks that can be connected. I/O Connecting Cables Select from Five I/O Connecting Cables CABLE LENGTH (CM) PART NUMBER 30 C200H-CN311 70 C200H-CN711 200 C200H-CN221 500 C200H-CN521 1,000 C200H-CN131 Note: The total length of the I/O Connecting Cables used in a network must not exceed 12 m. 21  DISCRETE I/O MODULES Connector Style A NK APP. MADE IN JAPAN NK APP. MADE IN JAPAN Connector Style B LOT No. Corporation OMRON LOT No. Corporation 02X2F OMRON C200H--OC222 OUTPUT UNIT LOT No. Corporation 29XOF OMRON C200H--OA121--E OUTPUT UNIT NK APP. MADE IN JAPAN OVERVIEW Discrete I/O modules are available in a number of voltages, densities, terminal block, and connector types. Connector-style high-density I/O modules with 32 or 64 discrete I/O points per module have solder connectors included with the module. Optional wiring methods are available using Omron’s I/O blocks, screw terminal, crimp and ribbon connectors, and pre-terminated cables. These versatile high-density configuration options minimize rack space and wiring time. The Omron I/O Blocks provide single-point isolation and up to 5 A current capacity per point. Replaceable relays and solid-state plug-in modules allow easy maintenance. There are five styles of discrete I/O modules in the C200H family. The profiles of each are shown here. Each module in the following pages is cross-referenced to the module style. Modules include the appropriate connectors. Connector Style C Features • Versatile high-density configuration options minimize rack space and wiring time LOT No. Corporation OMRON NK APP. MADE IN JAPAN • Replaceable relays and solid-state plug-in modules mean easy maintenance Connector Style D Connector Style E Discrete I/O Modules -- Varying Connector Types 22  DISCRETE I/O MODULES INPUT MODULE SPECIFICATIONS Input Module Specifications TYPE AC Input DC Input AC/DC Input Note: NO. OF INPUTS INPUTS PER COMMON INPUT VOLTAGE INPUT CURRENT OPERATING VOLTAGE INPUT RESPONSE TIME ON OFF ON OFF 8 pts 8 pts. 100 to 120 VAC +10%/--15% 10 mA, 100 VAC 60 VAC min min. 20 VAC max max. 35 ms max max. 55 ms max max. 16 pts. 16 pts. 8 pts. 8 pts. 16 pts. 16 pts. 200 to 240 VAC +10%/--15% 10%/ 15% 10 mA, 200 VAC 120 VAC min. i 40 VAC max. 8 pts. 8 pts. 12 to 24 VDC +10%/--15% 10 mA, 24 VDC 10.2 VDC min. 3.0 VDC max. 16 pts. 16 pts. 24 VDC +10%/--15% 7 mA, 24 VDC 14.4 VDC min. 5.0 VDC max. 8 pts. 8 pts. 12 to 24 VAC/DC +10%/--15% 10 mA, 24 VDC 10.2 VDC min. 3.0 VDC max. 16 pts. 16 pts. 24 VAC/DC +10%/--15% 7 mA, 24 VAC/ DC 14.4 VDC min. 5.0 VDC max. MODULE- PART NUMBER STYLE 1.5 ms max. 15 ms max. 1.5 ms max. 15 ms max. A C200H-IA121 B C200H-IA122 A C200H-IA221 B C200H-IA222 A C200H-ID211 B C200H-ID212 A C200H-IM211 B C200H-IM212 1. All models feature photocoupler isolation and LED indicator. 2. Each Discrete I/O Module has a removable terminal block. See the above STYLE column for a reference to the module style/connector type and refer to the accompanying drawing and chart for specific connector details. Input Module Circuit Configuration AC Input: IA121, IA122, IA221, IA222 C R1 COM IA121, IA122: IA221: IA222: 910Ω R1 330 kΩ 680 kΩ 680 kΩ C 0.33 µF 0.15 µF 0.15 µF R2 470 Ω 820 Ω 680 Ω V (AC) 100 to 120 200 to 240 200 to 240 IN R 18 kΩ + + COM 0.01 µF R ID211: 2 kΩ ID212: 3 kΩ Internal circuits ~ R2 Internal circuits IN DC Input: ID211, ID212 V (DC) 12 to 24 24 AC/DC Input: IM211, IM212 + + R 18 kΩ ~ COM 0.01 µF IM211: IM212: R 2 kΩ 3 kΩ Internal circuits IN V 12 to 24 VAC/DC 24 VAC/DC 23  DISCRETE I/O MODULES OUTPUT MODULE SPECIFICATIONS Output Module Specifications No. of outputs Rated load voltage Max. load current Min. switching capacity Output response times ON OFF 10 ms max. 10 ms max. Leakage current Outputs/ per common Fuse External power supply Internal power consumption (VDC) --- 8 pts. --- --- 10 mA max. Relay Output 8 pts. 12 pts. 250 VAC (cos φ = 1)/ 250 VAC ( (cos 0 4)/ φ = 0.4)/ 24 VDC max. Relay Output 2 A/pt. 8 A/8 pts. 10 mA, 5 VDC C200H-OC221 2 A/pt. 8 A/ 12 pts. 12 pts. C200H-OC222 (see note) 16 pts. 2 A/pt. 8 A/ 16 pts. 16 pts. 50 mA max. C200H-OC225 (see note) 5 pts. 2 A/pt. 10 A/5 pts. 1 pt. 10 mA max. C200H-OC223 8 pts. 2 A pts. 16 A/8 pts. C200H-OC224 Triac Output Triac Output 8 pts. 120 VAC 1 A/pt. 4 A/8 pts. 12 pts. 250 VAC, 50/60 Hz 0.3 A/pt. 2 A/12 pts. Resistive load: A 10 mA; inductive load: 40 mA (10 VAC) 1 ms max. 1 ms max. 8 pts. 1.2 A/pt. 4 A/8 pts. Resistive load: 100 mA; inductive load: 50 mA (10 VAC) 12 pts. 0.5 A/pt. 2 A/12 pts. 100 mA, 10 VAC; 50 mA, 24 VAC; 100 mA, 100 VAC 1/2 of load frequency max. 1/2 of load f frequency max. 1/2 + 1 ms of load frequency max. 3 mA max., VAC; 100 VAC A max., 6 mA 200 VAC 1.5 mA max., 120 VAC; 3 mA max., 240 VAC 8 pts. 5A 140 mA max. C200H-OA121-E 12 pts. 3A 200 mA max. C200H-OA222V 8 pts. 5A 180 mA max. C200H-OA223 12 pts. 3.15 A 270 mA max. C200H-OA224 Transistor Output 8 pts. 12 pts. Transistor Output 12 to 48 VDC +10%/--15% 1 A/pt. 3 A/8 pts. 24 VDC +10%/--15% 2.1 A/pt. 5.2 A/8 pts. 0.2 ms max. 0.3 ms max. 0.1 mA max. Residual voltage: 1.5 V max. 1 ms max. 1 ms max. 1 mA max. 5 to 24 VDC 0.3 A/pt. 10 mA, 5 VDC 1.5 ms max. 2 ms max. 0.1 mA max. 24 VDC +10%/--15% 0.3 A/pt. 2A/12 pts. Residual voltage: 1.4 V max. 0.2 ms max. 0.3 ms max. 0.3 A/pt. 4.8 A/12 pts 12 pts. 5 to 24 VDC 0.3 A/pt. 16 pts. 24 VDC +10%/--15% 1 A/pt. 4 A/16 pts. Note: Residual voltage: 1.4 V max. 0.8 A/pt. 2.4 A/8 pts. 16 pts. 24 Part number 10 mA, 5 VDC 1.5 ms max. 2 ms max. 8 pts. 5A 30 mA, 12 to 48 VDC min. 140 mA max. C200H-OD411 8A 30 mA, 24 VDC min. C200H-OD213 None 150 mA, 24 VDC min. C200H-OD214 5 to 24 VDC 10 mA max. C200H-OD216 12 pts. 5A 25 mA, 24 VDC min. 160 mA max. C200H-OD211 16 pts. 8A 35 mA, 24 VDC min. 180 mA max. C200H-OD212 12 pts. None 5 to 24 VDC 10 mA max. C200H-OD217 160 mA max. C200H-OD21A Residual 0.1 0.3 16 pts. 35 mA, 24 voltage: ms ms VDC min. 0.8 V max. max. max. Do not exceed the load current of 8 A per common. No more than 8 outputs can be turned ON simultaneously.  DISCRETE I/O MODULES OUTPUT MODULE SPECIFICATIONS Output Module Circuit Configuration Relay Output: OC221, OC222, OC223, OC224, OC225 Triac Output: OA222V, OA121-E OUT Internal circuits L + X L Internal circuits OUT + COM Fuse blowout detector COM OA222V: no fuse blowout detector Use either + or -- VDC Triac Output: OA223, OA224 OUT L Transistor Output: OD411/OD211 +V Output indicator LED Internal circuits COM Fuse Internal circuits L 250 VAC max. Fuse blowout detector L + COM Fuse Fuse blowout detector “F” LED “F” LED OUT OD211: no fuse blowout detector OA224: no fuse blowout detector Transistor Output: OD213/OD212 Transistor Output (Source Type): OD214 +V Output LED Output indicator OUT Internal circuits “F” LED Internal circuits LED L + Fuse COM Fuse blowout detector indicator +V OUT Source driver L + + 24 VDC COM Reset switch Alarm output LED OD212: No fuse blowout detector Transistor Output (Protective Circuit for Load Short-circuit): OD216/OD217 Output indicator LED +V OUT RESET L + COM 5 to 24 VDC Internal circuits Internal circuits Note: Transistor Output (Source Type with Protective Circuit for Load Short-circuit): OD21A + LED 24 VDC OUT00 L OUT15 L COM ALARM Fuse blowout detection circuit: The F indicator is lit and the 08 bit turns ON. The 08 to 15 bits cannot be used as ordinary IR bits. 25  SPECIAL I/O MODULES B7A INTERFACE MODULES The C200H-B7A Interface Modules reduce wiring from 16 input devices or 16 output devices to a few wires. The B7A allows you to remotely connect I/O that would have required direct connection to the PLC. You save control panel space, wiring time, and man-hours required for installation. These modules can be used with the full range of B7A input and output blocks for 16 I/O. The modules require a power supply, as do the terminal blocks. C200H-B7Al1 (16 Input Points) Features • Connect directly to the B7A I/O blocks using a two-conductor wire C200H-B7AO1 (16 Output Points) • Transmission distance up to 500 m max. C200H-B7A12 (32 Input Points) C200H-B7A21 (16 Input and 16 Output Points) 26 C200H-B7A02 (32 Output Points) C200H-B7A22 (32 Input and 32 Output Points)  SPECIAL I/O MODULES B7A INTERFACE MODULES System Configuration B7A input 32 pts./output 32 pts. B7A input 16 pts./output 16 pts. B7A output 32 pts. B7A input 32 pts. C200HX/HG/HE B7A Link Terminals Input Note: Input Output Output Input Output Input Input Output Output Refer to the B7A Link Terminals Datasheet (Q101) for more details. 27  SPECIAL I/O MODULES B7A INTERFACE MODULE Performance Specifications PART NUMBER C200H-B7AI1 C200H-B7AO1 C200H-B7A12 B7A INTERFACE MODULES C200H-B7A02 C200H-B7A22 16 output points and 16 input points or 15 input points + 1 error input 32 output points and 32 input points or 30 input points + 2 error inputs I/O points 16 points or 15 points and 1 error input Transmission distance 500 m max. if power is supplied to the Interface Module and B7A Link Terminal separately. Standard: 500 m max. using separate power supplies. 100 m max. using a common power supply. 100 m max. if power is supplied to the Interface Module and B7A Link Terminal from a single power supply. High-speed: 100 m max. using separate power supplies. 50 m max. using a common power supply. If shielded cable is not used, the maximum transmission distance is 10 m regardless of whether a common or separate power supplies are used. 19.2 ms typical, 31 ms max. Standard: 19.2 ms typical, 31 ms max. High-speed: 3 ms typical, 5 ms max. (see note 1) 0.05 A min. 0.06 A min. Transmission delay 16 output points 32 input points or 30 input points and 2 error inputs 32 output points Internal current consumption 5 VDC, 100 mA max. External power ower supply su ly ( (see note t 2) 12 to 24 VDC ±10% Weight 200 g max. 300 g max. Word allocations Same as I/O Modules (in order mounted). The words allocated to Group-2 B7A Interface Modules are determined by I/O number set on the Modules. Words 030 to 049 allocated according to I/O number setting. Modules with 32 I/O points are allocated two words; Modules with 64 I/O points are allocated four words. Note: 0.01 A min. 0.03 A min. 1. The transmission delay is changed by using the DIP switch. 2. The value of the external power supply does not include the value required by the B7A Link Terminal. Connectable B7A Link Terminals Input Terminals TYPE TRANSMISSION DELAY PART NUMBER Screw terminals Standard (19.2 ms) B7A-T6 1   B7A-T66 B7AS-T66 B7AS-T6 1 High-speed High s eed (3 ms) Modular Standard (19.2 ms) B7A-T6D2 High-speed (3 ms) B7A-T6D7 Standard (19.2 ms) B7A-T E3 High-speed (3 ms) B7A-T E8 TYPE TRANSMISSION DELAY PART NUMBER Screw terminals Standard (19.2 ms) B7A-R6 PLC connectors   Output Terminals 1 1 B7A-R66 B7AS-R66 B7AS-R6 High-speed High s eed (3 ms) Modular PLC connectors 28 C200H-B7A21 GROUP-2 B7A INTERFACE MODULES Standard (19.2 ms) B7A-R6A52 High-speed (3 ms) B7A-R6A57 Standard (19.2 ms) B7A-R A 3 High-speed (3 ms) B7A-R A 8   0.05 A min. 0.08 A min.  SPECIAL I/O MODULES HIGH-DENSITY INPUT MODULE SPECIFICATIONS (GROUP-2) The High-density Input Modules let you pack more input points into a single I/O slot for greater space savings. These modules do not use standard I/O points. Thus, they increase the overall I/O capacity. They provide 32 or 64 discrete input points. The modules can be used with Omron’s Terminal Blocks, reducing wiring between control panels, as well as within control panels. Features  • Easy cable connection to Omron’s XW2B- Terminal Blocks using XW2Z- Connecting Cable. Refer to the Standard Parts section for detailed ordering information.  C200H-ID216 (32 DC input pts.) C200H-ID217 (64 DC input pts.) • Up to ten 64-point modules or 32-point modules per PLC Note: The ambient temperature affects the number of points that can be ON simultaneously. Specifications PART NUMBER C200H-ID216 C200H-ID217 Number of inputs 32 points 64 points Rated input voltage 24 VDC +10%/--15% Input current 4.1 mA typical at 24 VDC Input impedance 5.6 kΩ ON voltage 14.4 VDC min. OFF voltage 5.0 VDC max. Input ON delay 1.0 ms max. Input OFF delay 1.0 ms max. Isolation Photocoupler Input indicator LED External connections Connector Number of circuits (see note) 32 points with one common 64 points with two commons Internal power consumption 100 mA max. at 5 VDC 120 mA max. at 5 VDC Weight 180 g max. 250 g max. Manual W302 Circuit Configuration ID216 COM 680 Ω 5.6KΩ to A CN1/CN2 IN15 Input indicator B Note: 1. The polarity of the input power supply source can be positive or negative provided that the polarity of each common is the same. 2. Although each COM is internally connected, wire them all. 3. The mountable number of High-density I/O Modules varies with the CPU. No High-density I/O Module can be mounted to the Slave Rack. IN00 to IN07 COM IN08 to IN15 COM IN00 to IN07 IN08 to IN15 1000 PF A B CN1 SW CN2 Input indicator A ID111: 820 Ω ID217: 680 Ω B 2.7 kΩ 5.6 kΩ 29 Display switch 1000 PF Internal circuits A/B IN00 to IN07 COM IN08 Internal circuits ID217 COM  SPECIAL I/O MODULES HIGH-DENSITY OUTPUT MODULE SPECIFICATIONS (GROUP-2) Using the High-density Output Modules, you pack more output points into a single I/O slot for greater space savings. These modules increase the overall I/O capacity, while not using standard I/O points. They provide 32 or 64 discrete output points. The modules can be used with Omron’s Terminal Blocks and Cables, reducing wring between control panels, as well as within control panels. Features  • Easy cable connection to Omron’s XW2B- Terminal Blocks using XW2Z- Connecting Cable. Refer to the Standard Parts section for detailed ordering information.  C200H-OD218 C200H-OD219 (32 DC output pts.) (64 DC output pts.) • Up to ten 64-point modules or 32-point modules per PLC Specifications PART NUMBER C200H-OD218 C200H-OD219 Number of outputs 32 points 64 points Max. switching capacity 16 mA at 4.5 V to 100 mA at 26.4 V Leakage current 0.1 mA max. Residual voltage 0.8 V max. Input ON delay 0.1 ms max. Input OFF delay 0.4 ms max. Output indicator LED External connections Connector Number of circuits 32 points with one common Fuse (see note) 3.5 A (one/common) External power supply 110 mA (3.4 mA per ON pt) min. at 5 to 24 VDC ±10% 220 mA (3.4 mA per ON pt) min. at 5 to 24 VDC ±10% Internal power consumption 180 mA max. at 5 VDC 260 mA max. at 5 VDC Manual W302 Note: 64 points with two commons The fuse is not user replaceable. Circuit Configuration OD218 OD219 OUT00 to OUT07 Output indicator COM F indicator Fuse 3.5A OUT08 to OUT15 COM 4.5 to 26.4 VDC OUT00 to OUT07 COM 4.5 to 26.4 VDC OUT08 to OUT15 COM 30 A OUT00 to OUT07 COM 4.5 to 26.4 VDC Output indicator Fuse break detec tor 4.5 to 26.4 VDC Internal circuits Internal circuits 4.5 to 26.4 VDC Fuse CN1 SW Display switch/ fuse break detector Output indicator 4.5 to 26.4 VDC OUT08 to OUT15 COM CN2 F indicator B Note: The number of Group-2 High-density Output Modules is limited by the CPU model. They cannot be used with the Slave Rack. CN1/ CN2  SPECIAL I/O MODULES ANALOG TIMER MODULE The Analog Timer Module lets the user fine-tune timer values manually, without going into the PLC program. Adjustments can be made from the front part of the module or from remote locations (using a special cable and external variable resistors).The module has four independently set and monitored timers that each have variable ranges. The user may select, by DIP switch, for each point to use front panel variable resistor or external variable resistors. Through internal bit allocation, each timer can be started and paused, allowing for them to be used as cumulative timers. Features C200H-TM001 • Four front panel variable resistors are used to set the timers • Connecting Cable No. C4K-CN233 available for external variable resistors • Indicators show operation and time-up status • Cumulative timer available using pause bits • Timer values may be adjusted without program changes System Configuration Specifications PART NUMBER C200H-TM001 Timing method CR oscillator No. of timers 4 Setting ranges 0.1 to 1.0 s, 1 to 10 s, 10 to 60 s, 1 to 10 min Operation Controllable from PLC program. Usable as accumulating timer. External adjustment Via C4K-CN223 (2 m) connector to 20-kΩ resistor Manual W302 C200HX/HG/HE C4K-CN223 (2 m) External adjustments mounted as required by application. 31  SPECIAL I/O MODULES INTERRUPT INPUT MODULE The Interrupt Input Module allows real world discrete inputs to interrupt the scan of the main ladder logic program and execute specific interrupt ladder logic. For systems requiring immediate response and fast throughput from field input signals, the Interrupt Input Module can provide fast sub-scan execution and response times. The Module can be configured to provide immediate interrupts and scheduled interrupts which repeat execution on a preset time base. Interrupts can also be configured to interrupt currently executing interrupt logic. Features C200HS-INT01 • Using input interrupts, the Interrupt Input Module temporarily interrupts the main program to execute interrupt subroutines • High-speed immediate or scheduled logic execution • Provides sub-scan response to field input signals • Ladder instructions control and monitor interrupt inputs Specifications PART NUMBER C200HS-INT01 Rated Input Voltage 12 to 24 VDC +10%/--15% Input Impedance 2 KΩ Input Current 10 mA typical (24 VDC) ON Voltage 10.2 VDC min. OFF Voltage 3.0 VDC max. ON Response Time 0.2 ms max. OFF Response Time 0.5 ms max. No. of Circuits 1 (8 points/common) Internal Current Consumption 20 mA, 5 VDC max. Weight 200 g max. Manual W302 Note: 32 The Interrupt Input Module must be mounted on the CPU Rack. Only two Interrupt Input Modules can be mounted per CPU Rack.  SPECIAL I/O MODULES INTERRUPT INPUT MODULE Interrupt Input Operation The above application shows input bits IR 00400 through IR 00407 assigned to subroutines 00 to 07. For example, when the input for IR 00400 goes ON, normal program execution is interrupted and the subroutine between SBN 000 and RET is executed. If required, outputs can be refreshed immediately by programming the I/O REFRESH instruction within the subroutine. Normal program area END(01) SBN(92) 00 IORF(97) Input ON 003 003 IR 00400 SBN 000 IR 00401 SBN 001 IR 00402 SBN 002 Interrupt subroutine program area RET(93) IR 00407 Note: SBN 007 Only the word 003 output processed in the interrupt subroutine program is immediately refreshed. If the Interrupt Input Module is mounted on an Expansion I/O Rack, the interrupt function cannot be used, and the Interrupt Input Module will be treated as an ordinary 8-point Input Module. Interrupt Input Modules cannot be used on Slave Racks. Circuit Configuration IN IN 2 kΩ COM 0.01 µF 1.8 kΩ Internal Circuit 12 to 24 VDC Input indicator The polarity of the input power supply source can be positive or negative provided that the polarity of each common is the same. 33  SPECIAL I/O MODULES HIGH-DENSITY INPUT MODULE The High-density Input Modules let you pack more input points into a single I/O slot for greater space savings. Functioning as as Special I/O modules, they do not use standard I/O points. Thus, they increase the overall I/O capacity. They provide 32 discrete input points with selectable response times of 2.5 ms or 15 ms. For even shorter signals, 8 inputs can be designated as quick-response inputs, to receive selectable 1 ms or 4 ms signals. The modules can also be used with Omron’s Terminal Blocks, reducing wiring between control panels as well as within control panels. C200H-ID215 (DC input) C200H-ID501 (TTL input) Features • 8 quick-response inputs available to receive short signals  • Easy cable connection to Omron’s XW2B- Terminal Blocks using XW2Z- Connecting Cable. Refer to the Standard Parts section for detailed ordering information.  • Selectable input response time • LED indicator • Provides a photocoupler for isolation Specifications PART NUMBER C200H-ID215 C200H-ID501 MODULE NAME DC INPUT MODULE TTL INPUT MODULE No. of inputs 32 Input voltage and input current 24 VDC ±10%/--15% 4.1 mA, 24 VDC 5 VDC ±10%; 3.5 mA, 5 VDC Operating voltages ON: 14.4 VDC min. OFF: 5.0 VDC max. ON: 3.0 VDC min. OFF: 1.0 VDC max. Output response times ON: 2.5/1.5 ms (selectable) OFF: 2.5/15 ms (selectable) Inputs per common 8 pts (4 circuits) Internal current consumption 130 mA max. (5VDC) Manual W302 Note: 34 High-density Modules are equipped with quick-response functions and have Special I/O functions. When mounting these models to a SYSMAC BUS Slave, the Remote I/O Master must be the C200H-RM001-PV1 or C200HRM201.  SPECIAL I/O MODULES HIGH-DENSITY INPUT MODULE Circuit Configuration TTL Input: ID501 DC Input: ID215 + IN 5.6 kΩ 5 VDC + + IN 2.4 kΩ 1.1 kΩ Internal circuits 24 VDC 1000 pF + COM Internal circuits 620 Ω COM Connect to either + or -- terminal on DC power supply. I/O Refresh Instruction The I/O Refresh instruction, IORF(97), can be used with the quick-response input function to read the input status held in the quick-response input buffer whenever needed in a program. 00000 Machine Number Setting and Input Bit No. When set to machine No.: n (0 to 9), words [100+10n+1] can be used as input bits. Input bits 08 to 15 of word 1n1 can be used as quick-response inputs. IORF(97) St E When 00000 is ON, all words from St to E will be refreshed. St and E would be 101 for Unit #0, making bits IR 10108 to IR 10115 quick-response input bits. Example: When set to 8, input bits 18108 to 18115 become quick-response inputs. Machine No. setting switch Quick-response Input Operation and Timing With quick-response input function these High-density I/O Modules can read short-pulse input signals, such as those from photomicrosensors. With standard I/O Modules, an input must be ON during the I/O refresh period for it to be read into the PLC. Input signals shorter than the cycle time can be missed, unless they happen to occur during the I/O refresh. The quick-response input buffer (on our High-density and Mixed I/O Module) is used to hold input signals as short as 1 ms or 4 ms (selectable) allowing them to be read into the IR area during the next I/O refresh. (Any pulse that is equal to or longer than the minimum time setting affects the program during the next program execution.) The quick-response input function is available on input points number 08 to 15 on CN2. 35  SPECIAL I/O MODULES HIGH-DENSITY OUTPUT MODULE The High-density Output Modules let you pack more output points into a single I/O slot for greater space savings. Treated as Special I/O modules, they do not use standard I/O points. Thus, they increase the overall I/O capacity. In static high-density mode, they provide 32 discrete output points. In this mode, the modules can also be used with Omron’s Terminal Blocks, reducing wiring between control panels as well as within control panels. In dynamic multiplex mode, the modules provide 128 dynamic output points. In this mode they can be used with numeric displays, etc. Features • Provide 32 outputs per module in static mode C200H-OD215 (32 transistor output pts.) C200H-OD501 (32 TTL output pts.)  • Easy cable connection to Omron’s XW2B- Terminal Blocks using XW2Z- Connecting Cable. Refer to the Standard Parts section for detailed ordering information.  • Provide interface to numeric displays, etc. in dynamic mode Specifications PART NUMBER C200H-OD215 C200H-OD501 MODULE NAME TRANSISTOR OUTPUT TTL OUTPUT No. of outputs 32 Rated load voltage 5 to 24 VDC +10%/--15% 5 VDC ±10%; Max. load current 16 mA at 4.5 V to 100 mA at 26.4 V/pt. 800 mA/8 pts. 3.2 A/32 pts. 35 mA/pt. 280 mA/8 pts. 1.12 A/32 pts. Outputs per common 8 pts Output response times ON: 0.2 ms max. OFF: 0.6 ms max. External connection connector Residual voltage 0.7 V max. Leakage current 0.1 mA max External power supply 90 mA, 5 to 24 VDC min. Internal power consumption 220 mA max. Manual W302 Note: 36 ON: 0.2 ms max. OFF: 0.3 ms max. 0.4 V max. 39 mA, 5 VDC min. When mounting these models to a Slave Rack, the Remote I/I Master must be the C200H-RM001-PV1 or C200H-RM201.  SPECIAL I/O MODULES HIGH-DENSITY OUTPUT MODULE Dynamic Output Mode for Digital Displays With dynamic outputs, data signals DATA0 to DATA15 are combined with strobe signals STB0 to STB15 to reduce wiring and greatly increase output capacity. The output device must be able to receive dynamic signals. Circuit Configuration Transistor Output: OD215/TTL Output: OD501 OUT Internal circuits Position Control Module C200H-NC111/NC112 R3 L + Fuse OD501: OD215: R1 4.7 kΩ None V Common V 5 VDC 5 to 24 VDC C200HX/HG/HE M7F Servomotor Servodriver 37  SPECIAL I/O MODULES MIXED I/O MODULE The high-density/multiplex mixed Input/Output modules let you pack more I/O points into a single I/O slot for greater space savings. Treated as Special I/O modules, they do not use standard I/O points. Thus, they increase the overall I/O capacity. In static high-density mode, they provide 16 discrete input points and 16 discrete output points with selectable input response times of 2.5 ms or 15 ms. For even shorter input signals, 8 inputs can be designated as quick-response inputs, to receive selectable 1 ms or 4 ms signals. In this mode, the modules can also be used with Omron’s Terminal Blocks, reducing wiring between control panels as well as within control panels. C200H-MD215/MD115 (16 DC input/16 transistor output pts.) C200H-MD501 (16 TTL input/16 TTL output pts.) In dynamic multiplex input mode, the modules provide 128 dynamic input points. In this mode they can be used with keyboards, thumbwheel switches, etc. Features • Provide 16 inputs and 16 outputs per module in static mode; 128 inputs in dynamic mode  • Easy cable connection to Omron’s XW2B- Terminal Blocks using XW2Z- Connecting Cable. Refer to the Standard Parts section for detailed ordering information.  • Selectable input response time • Up to 10 Special I/O modules per PLC • Provide interface to keyboards, thumbwheel switches, etc. in dynamic mode Specifications MODULE NAME TTL INPUT/OUTPUT MODULE DC INPUT/TRANSISTOR OUTPUT MODULE PART NUMBER C200H-MD501 C200H-MD215 C200H-MD115 Inputs No. of inputs 16 pts Input voltage and current 5 VDC ±10%, 3.5 mA (5 VDC) 24 VDC +10%--15%, 4.1 mA (24 VDC) 12 VDC +10%--15%, 4.1 mA typical (12 VDC) Operating voltages ON: 3.0 V min., OFF: 1.0 V max. ON: 14.4 V min., OFF: 5.0 V max. ON: 8.0 V min., OFF: 3.0 V max. Input response times ON/OFF: 2.5 ms/15 ms (selectable) Isolations Photocoupler Inputs per common 8 pts No. of outputs 16 pts Rated load voltage 5 VDC 5 to 24 VDC 12 VDC Max. load current 35 mA/pt, 280 mA/8 pts 100 mA/pt, 800 mA/8 pts 100 mA/pt, 800 mA/8 pts Residual voltage 0.4 V max. 0.7 V max. Output response times ON: 0.2 ms max., OFF: 0.3 ms max. ON: 0.2 ms max., OFF: 0.6 ms max. Leakage current 0.1 mA max. Outputs per common 8 pts Fuse Present (replacement not possible) Outputs External connection Connector Internal current consumption (5 VDC) 180 mA max. Manual W302 Note: 38 When mounting any of the above models to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-RM201.  SPECIAL I/O MODULES MIXED I/O MODULE Circuit Configuration MD501/MD215/MD115 Internal circuits R1 L + V1 OUT Fuse R3 R2 C COM IN + + V2 COM Dynamic Input Mode Operation and Timing With dynamic inputs, data signals DATA0 to DATA15 are combined with strobe signals STB0 to STB15 to reduce wiring and greatly increase input capacity. For example, when STB0 is ON, as shown to the right, data would be read from DATA0 to DATA3, and the status of switches A through D would be reflected in bits 00 through 03 of word 1n0, where n is the Special I/O Module’s unit number. R1 R2 R3 C V1 V2 MD501 4.7 kΩ 1.1 kΩ 2.4 kΩ None 5 VDC 5 VDC MD215 None 5.6 kΩ 620 Ω 1000 pF 5 to 24 VDC 24 VDC MD115 None 2.7 kΩ 620 Ω 1000 pF 5 to 24 VDC 12 VDC STB0 (CN1 A1) D C B A DATA0 (CN2 A1) DATA1 (CN2 A2) DATA2 (CN2 A3) DATA3 (CN2 A4) 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 Wd 1n0 Wd 1n1 Wd 1n2 to Wd 1n7 D C B A 39  SPECIAL I/O MODULES ANALOG INPUT MODULES Analog Input Modules accept a variety of analog signals from external devices, including both voltage and current ranges. Both Modules provide 12-bit resolutions and fast access to the PLC. Features • Cost-effective single-slot modules available with 4 or 8 analog inputs C200H-AD001 • 12-bit resolution C200H-AD002 • Selectable ranges include 1 to 5 V, 0 to 10 V, and 4 to 20 mA Specifications System Configuration PART NUMBER C200H-AD001 C200H-AD002 Input points 4 8 Voltage input 1 to 5V or 0 to 10 V 1 to 5 V, 0 to 10 V, or --10 to 10 V Current input 4 to 20 mA External in ut im ed input impedance Voltage input 1 MΩ min. Current input 250 Ω Resolution Voltage 1/4,000 FS Current Total precision C200HX/HG/HE Flow Temperature Current Transducer Pressure Analog input Voltage Analog signals, such as voltages and currents, are received from various sensors through the maximum of 8 inputs (AD002) and converted into 12-bit binary data. External input signal range can be freely set to cope with diverse needs. Built-in functions included: the scaling function, mean function, peak hold function, square-root extraction function, and more. 40 25°C 77.0°F ±0.5% FS Voltage: ±0.25% FS Current: ±0.4% FS 0° to 55°C (32° to 131°F) ±1.0% FS Voltage: ±0.6% FS Current: ±0.8% FS Conversion speed 2.5 ms max./pt Converted data 12-bit binary Maximum input ut signals Voltage input ±15 V max. Current input ±30 mA max. 12-bit binary or 4-digit BCD code (selectable) I/O words required 10 (Special I/O area) External connections Terminal block Connector Current consumption 550 mA max., 5 VDC 450 mA max., 5 VDC Weight 450 g max. 290 g max. Manual W127 W229  SPECIAL I/O MODULES ANALOG OUTPUT MODULES Analog Output Module provides an interface to a variety of external analog devices that accept voltage and current ranges, including servo controllers, recorders, and analog gauges. Features • Cost-effective single-slot module offers two or four analog outputs • 12-bit resolution • Selectable ranges include 1 to 5 V, 0 to 10 V, -10 to +10 V, and 4 to 20 mA C200H-DA001 Specifications C200H-DA002 PART NUMBER C200H-DA001 C200H-DA002 Output points 2 4 Voltage output 1 to 5V or 0 to 10 V --10 to 10 V Resolution Total precision Current output 4 to 20 mA Voltage 1/4,095 FS Current 1/4,095 FS 25°C 77.0°F ±0.5% FS Voltage: ±0.3% FS Current: ±0.5% FS 0° to 55°C (32° to 131°F) ±1.0% FS Voltage: ±0.5% FS Current: ±1.0% FS 1/8,190 FS Conversion speed 2.5 ms max./pt External output impedance 0.5 Ω min. Maximum external output current Voltage output 15 mA Current output --- Voltage output --- Current output 400 Ω 350 Ω 12-bit binary Voltage code bit + 12-bit binary Current code bit + 12-bit binary Allowable load resistance of external output System Configuration C200HX/HG/HE 10 mA Analog output Servomotor driver Inverter Converted data I/O words required 10 (Special I/O area) External connections Terminal block Connector Current consumption 650 mA max., 5 VDC 600 mA max., 5 VDC Weight 450 g max. 320 g max. Manual W127 W260 M Recorder Converts 12-bit binary data into analog signals (voltage or current) for output to external devices. Output signal range can be freely set to cope with diverse needs. Built-in functions such as the output limit, upper- and lower-limit alarm, and pulse output functions make the C200HX/HG/HE even more powerful. 41  SPECIAL I/O MODULES TEMPERATURE SENSOR MODULES Monitor up to 4 temperature sensor inputs directly from the PLC rack. Choose thermocouple inputs (types J and K), or platinum RTD inputs. Each module offers multiple ranges and a choice of Fahrenheit or Celsius scaling. Features • Available for thermocouple types J and K, or platinum RTD temperature sensors • Selectable number of inputs • Wide range of temperature settings C200H-TS001 C200H-TS101 Specifications PART NUMBER C200H-TS001 C200H-TS101 TYPE THERMOCOUPLE PLATINUM RESISTANCE THERMOMETER Temperature sensor Thermocouples: K (CA), J (IC) (selectable) RTD (JPt 100 Ω) Input points 4 points/Unit max. (1, 2, or 4 points can be selected) Converted data ±(1% FS + 1°C) max. Total precision 4.8 s max. when 4 points/Unit is set 2.4 s max. when 2 points/Unit is set 1.2 s max. when 1 points/Unit is set PLC fetch time Conversion cycle + PLC1 cycle time (5 s max.) Insulation Between points: Uninsulated Between input terminal and PLC signal: Insulated with a photocoupler 42 I/O words required 10 (Special I/O area) Current consumption 450 mA max., 5 VDC Weight 400 g max. Manual W124  SPECIAL I/O MODULES TEMPERATURE SENSOR MODULES System Configuration External Connections Temperature Sensor Modules C200H-TS001/TS002/TS101/TS102 High-density Output Module C200H-TS101/TS102 Platinum Resistance Thermometer Input C200H-TS001/TS002 Thermocouple Input B0 + Input 1 A0 -- B0 A B1 B2 Input 2 A2 -- B1 B2 A B3 C200HX/HG/HE Input 1 A0 A1 A1 + + B B′ B B′ Input 2 A2 B3 A3 A3 B4 B4 -- A4 B’ B5 B5 A B A4 R0  G79- C Connecting Cable (1-to-1) + M7F A5 A5 B6 Input 3 A6 -- B6 A B B′ A B B′ B7 B8 Input 4 A8 -- B9 Note: B7 A7 A7 + Input 3 A6 B8 Input 4 A8 B9 A cold junction compensating circuit, whose precision is adjusted together with the Module, is provided between the B4 and B5 terminals of the C200H-TS001 (for thermocouple). Temperature Ranges C200H-TS101 C200H-TS001 Thermocouple Measuring element K (CA) Chromel/Alumel °C Unit °F °C Note: Measurement ranges 00 01 02 05 06 07 08 03 04 09 10 11 12 Pt 100 Ω °C Unit 1,600 1,000 800 Measure- 600 ment 500 ranges 400 300 200 150 100 80 50 0 Temp, spec code (2-digit BCD) Platinum Resistance thermometer Measuring element J (IC) Iron/Constantan 13 14 °F 500 400 300 200 150 100 80 50 0 --20 --50 Temp, spec code (2-digit BCD) 15 16 17 18 21 22 23 19 20 Use the IR bit for setting the temperature range. (Common settings for 4 inputs.) 43 24 25  SPECIAL I/O MODULES TEMPERATURE CONTROL MODULES Omron puts accurate temperature control right in the rack to make advanced PID control with auto-tuning readily accessible. Eliminates a need for stand-alone controllers with networks. Display and set parameters with the C200H-DSC01 Data Setting Console. Details on the Data Setting Console are provided later in this section.  C200H-TC10 C200H-TC00 Features • Auto-tuning of PID constants C200H-DSC01 Data Setting Console • The temperature controller accepts inputs from a thermocouple or platinum resistance thermometer. The module is switch-selectable offering ten different sensor types. • Transistor, voltage, or current output can be selected as the control output. • High speed and high accuracy temperature control is performed with a sampling period of 500 ms and with an indication accuracy of ±0.5%. • Eight data values such as main set value, alarm set value, and input shift range can be preset in one data bank and a maximum of eight data banks can be preset with each bank preset for a different purpose. It is possible to change the banks during operation. • Alarm outputs can be selected out of ten modes, such as an upper limit, lower limit, and upper/lower limit. • The heater current is monitored by the high-precision current transformer (CT) capable of detecting in 0.1 A units. Through the use of heater burnout detection, heater burnout can be quickly detected. • Data input and process value monitoring -- using the Data Setting Console. Specifications 44  C200H-TC10  PART NUMBER C200H-TC00 Current transformer detection current 0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max. Input points (no. of loops) Two points (two loops, each of which consists of a temperature sensor and CT) Temperature control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning) Preset memory bank items (8 max.) Main set value, alarm set value, input shift range, proportional band, integral time, derivative time, sensitivity adjustment, etc. Setting/Indication accuracy ±0.5% of set (designated) value or ±2°C whichever larger, ±1 digit max. Proportional band 0.0° to 999.9°C/°F (in units of 0.1°C/°F) Integral (reset) time 0 to 9,999 s (in units of 1 s) Derivative (rate) time 0 to 9,999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Sampling period 500 ms Input shift range --99.9° to 999.9°C/°F (in units of 0.1°C/°F) Alarm output mode Selectable from no alarm function, upper alarm, lower alarm, upper/lower alarm, upper-/lower-range alarm, upper/lower alarm with standby sequence, upper alarm with standby sequence, lower alarm with standby sequence, absolute-value upper alarm, or absolute-value lower alarm. No. of banks 8 banks Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane) External supply voltage 24 VDC +10%/--15%, 200 mA min. Weight 360 g max. Manual W225 ±0.5% of set (designated) value or ±1°C whichever larger, ±1 digit max.  SPECIAL I/O MODULES TEMPERATURE CONTROL MODULES CONTROL OUTPUT SENSOR PART NUMBER Transistor output Thermocou le: R, S, K(CA), J(IC), Thermocouple: T(CC) E(CRC) T(CC), E(CRC), B B, N N, L(IC) L(IC), U(CC) C200H-TC001 Voltage output Current output Transistor output Voltage output Current output C200H-TC002 C200H-TC003 Platinum resistance thermometer: JPt100 Pt100 JPt100, System Configuration C200H-TC101 Temperature Control Module C200HX/HG/HE C200H-TC102 C200H-TC103 Loop 1 Temperature sensor CT Loop 2 Temperature sensor CT C200H-DSC01 Data Setting Console Relay box for heater control 45  SPECIAL I/O MODULES HEAT/COOL TEMPERATURE CONTROL MODULES Omron puts accurate heat/cool control right in the rack to make advanced PID control with auto-tuning directly accessible on the PLC rack. For applications requiring tight process control, such as plastic extruders. Display and set parameters with the C200H-DSC01 Data Setting Console. Features  C200H-TV10 C200H-TV00 • For stable temperature control, use advanced PID and an auto-tuning feature. ON/OFF control can also be selected. C200H-DSC01 Data Setting Console • Dedicated Module available for each Temperature Sensor. Two types of Temperature Control Module are available, depending on the thermocouple or platinum resistance thermometer temperature sensor used. • Comprehensive output specifications -- three types are available: C200H-TV 1 for transistor output, C200H-TV 2 for voltage output, and C200H-TV 3 for current output.    • Two Heat/Cool Control loops with a single module • Heater burnout can be quickly detected -- a minimum current difference of 2.5 A and a heater burnout detection setting range of 0.1 to 49.9 A allows for the rapid correction. • Eight banks of data settings, such as set point (SP) and alarm set values, can be preset in eight data banks for easy selection. • Data Input and Display -- The C200H-DSC01 Data Setting Console (sold separately) is used to input data and display process values (PV) and set values (SV). The easy-to-read display can be panel-mounted. • Data reading/writing User Program of the C200HX/HG/HE allows reading or writing of various data. Specifications  C200H-TV10  PART NUMBER C200H-TV00 Current transformer detection current 0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max. Input points (no. of loops) Two points (two loops, each of which consists of a temperature sensor and CT) Temperature control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning) No. of banks 8 banks Setting/Indication accuracy (see note) ±0.5% of set (designated) value or ±2°C whichever larger, ±1 digit max. Hysteresis 0.0° to 999.9°C/°F (in units of 0.1°C/°F) Proportional band 0.0° to 999.9°C/°F (in units of 0.1°C/°F) Integral (reset) time 0 to 9,999 s (in units of 1 s) Derivative (rate) time 0 to 9,999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Sampling period 500 ms Input shift range --99.9° to 999.9°C/°F (in units of 0.1°C/°F) Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane) External supply voltage 24 VDC +10%/--15%, 200 mA min. Weight 360 g max. ±0.5% of set (designated) value or ±1°C whichever larger, ±1 digit max. Manual W240 Note: The indication accuracy of thermocouples R and S at a temperature of 200°C max., that of thermocouples K and T at a temperature of --100°C max., and that of thermocouple U are all ±4°C, ±1 digit max. The indication accuracy of thermocouple B at temperature of 400°C or below is not guaranteed. 46  SPECIAL I/O MODULES HEAT/COOL TEMPERATURE CONTROL MODULES CONTROL OUTPUT SENSOR PART NUMBER Transistor output Thermocou le: R, S, K, Thermocouple: J T N L J, T, E E, B B, N, L, U C200H-TV001 Voltage output Current output Transistor output Voltage output Current output C200H-TV002 C200H-TV003 Platinum resistance th thermometer: t JPt100 JPt100, Pt100 C200H-TV101 System Configuration Heat/Cool Temperature Control Module C200HX/HG/HE C200H-TV102 C200H-TV103 Loop 1 Temperature sensor CT Loop 2 C200H-DSC01 Data Setting Console Relay box for heater and coolant control Temperature sensor CT 47  SPECIAL I/O MODULES PID CONTROL MODULES This module provides two independent PID loops for process control right on the PLC rack. Based on Omron’s E5EX-LA process controller, the C200H-PID0 accepts both current and voltage analog inputs for pressure, flow and other measurements. The module can be programmed and controlled from the PLC or from the optional Data Setting Console. (Details on the Data Setting console are found later in this section.)   C200H-PID0 C200H-DSC01 Data Setting Console Features • Advanced PID -- stable PID control using advanced PID and an auto-tuning feature. ON/OFF control can also be selected. • High-speed sampling period of 100 ms -- a sampling period of 100 ms is achieved with two loops, enabling high-speed PID control. • Input noise reduction with digital filter -- mitigation of sudden input fluctuations makes the PID Control Module effective in quick-response systems. • Three types of output specification versions are available: C200H-PID01 for transistor output, C200H-PID02 for voltage output, and C200H-PID03 for current output. • Eight banks of data settings -- eight data values, including set point (SP) and alarm set values, can be preset in eight data banks for easy selection. • Data input and display using Data Setting Console to input data and display process values (PV) and set values (SV). Easy-to-read display can be panel-mounted. • Data reading/writing -- the user program of the C200HX/HG/HE allows reading or writing of various data. Specifications 48  PART NUMBER C200H-PID0 Input signal range 4 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V Input points (no. of loops) Two points (two loops, each of which consists of a voltage and a current) Control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID control with auto-tuning) No. of banks 8 banks Setting/Indication accuracy ±0.5% FS ±1 digit max. The SV and displayed value match. There is no relative error. Hysteresis 0.0 to 100.0% FS (in units of 0.1% FS) Proportional band 0.0 to 999.9 (in units of 0.1) Integral (reset) time 0 to 9,999 s (in units of 1 s) Derivative (rate) time 0 to 9,999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Sampling period 100 ms Input shift range --999 to 9,999 (decimal point position is designated by a parameter setting) Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane) External supply voltage 24 VDC +10%/--15%, 200 mA min. Weight 360 g max. Manual W241  SPECIAL I/O MODULES PID CONTROL MODULE OUTPUT PART NUMBER Transistor output (open collector) C200H-PID01 Voltage output C200H-PID02 Current output C200H-PID03 System Configuration PID Control Module Loop 1 Flow sensor CT C200HX/HG/HE C200H-DSC01 Data Setting Console Flow sensor Relay box for valve control Loop 2 CT 49  SPECIAL I/O MODULES DATA SETTING CONSOLE The C200H-DSC01 Data Setting Console mounts on the front panel to display data and provide operator interface for a rackmounted Temperature Controller Module, Cam Positioner Module and PID Modules. You will need one Data Setting Console to monitor each Module. Included with the C200H-DSC01 are mounting brackets, panel decals for modules to identify the modules and a temperature unit label. Features • Fits 1/8 DIN cutouts • 2 m or 4 m cable • Change set values, parameters C200H-DSC01 • Monitor present value, set value and memory bank number as well as output status Specifications 50 PART NUMBER C200H-DSC01 Size 1/8 DIN (48 x 96 mm) Applicable modules C200H-TC C200H-CP114 Display data Set value, present value, bank number, auto-tuning, heater burnout alarm, mode, bank, step, cam number, ON/OFF, run, alarm 1 and 2 Connecting cables 2 m: C200H-CN225 4 m: C200H-CN425 Enclosure rating IP20 (For NEMA 4 rating, use a Y29-49N cover.)  C200H-TV C200H-PID   SPECIAL I/O MODULE FUZZY LOGIC MODULE The Fuzzy Coprocessor Module allows state-of-the-art fuzzy logic inference processing to be closely integrated with Omron’s C200Hα PLCs. In addition to normal ladder logic control, the PLC CPU enables pre-processing and post-processing of fuzzy I/O, which is provided by standard Analog I/O Modules, and/or internal registers in the PLC CPU, using intelligent I/O READ and WRITE instructions in ladder logic. Fuzzy control is best applied to applications that rely heavily on human control and input such as control for overhead cranes, flow control, and temperature control. C200H-FZ001 Features • Up to 8 inputs, 4 outputs • Up to 128 rules • User-definable membership functions • PLC provides pre-processing and post-processing of fuzzy I/O • The C200HX/HG/HE can handle jobs that used to require highly-experienced operators. Specifications PART NUMBER Fuzzy logic processor Membership functions I/O words Peri heral device Peripheral i ti communications C200H-FZ001 I/O capacity 8 inputs and 4 outputs Rule format 8 condition and 2 conclusion parts max. Rule capacity 128 rules max. Logic process Forward logic Logic rule MAX--MIN logical product Number of labels 7 max. Final calculation Each output can be set independently for calculation by center of gravity, leftmost maximum, or rightmost maximum method. Rule with no grade Can be set to retain the previous value or take a preset value. Condition Defined by up to 4 end points. Grade (height) at the end points must be either 0 or 1 (0 or 4095). Resolution is 4095 by 4095. Conclusion Only the horizontal position is set. Height is fixed at 4095. Resolution is 4095 by 4095. Inputs 8 words max. Each input is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to 4095 decimal). Outputs 4 words max. Each output is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to 4095 decimal). Communications Half duplex Synchronization Start-stop synchronization Baud rate 300, 600, 1200, 2400, 4800, 9600, or 19200 (set on DIP switch 2) Transmission distance 15 m max. Interface RS-232C port Communications protocol Special procedure (1:N) Processing time Self-diagnostics 6 ms max. for Unit, 3 to 4 times the cycle time for system. Program check A “memory error” will be generated if an error occurs during the program check. Data retained in a power interruption Rules and membership functions are retained. Internal current consumption 5 VDC, 0.3 A max. (Supplied from the Backplane.) Weight 400 g max. Manual W208 51  SPECIAL I/O MODULES FUZZY LOGIC MODULE System Configuration Analog Output Module Fuzzy Logic Module Analog Input Module Analog inputs Analog outputs C200HX/HG/HE RS-232C cable (to 9-pin connector) Fuzzy Support Software C500-SU981-E To 25-pin connector IBM PC/AT or compatible 52  SPECIAL I/O MODULES DUAL-AXIS MOTION CONTROL MODULE The dual-axis motion controllers are compatible with servo drivers that accept analog inputs for a complete motion control system. Programs are stored internally in the module and can be selected and monitored from the extensive memory interface available in the PLC. The Motion Control Support Software (MCSS) provides the program editing, downloading, diagnostic, and on-line monitoring capability to reduce engineering, debugging, and start-up time. (Order separately.) Features C200H-MC221 • Dual-axis semi-closed loop servo control for simple servo positioning applications • Internal program storage for fast selection and execution of motion profiles • Extensive control and monitoring interface reduces maintenance and debugging • G Code Programming Language subset reduces program development time • A maximum of 100 programs can be registered • A maximum of eight modules can be mounted to a single C200HX/HG/HE PLC to control a maximum of 16 axes. Write Sophisticated Programs Easily -with G-language Programming and MC Support Software. The functions of the MC Module are set with the MC Support Software. The MC Support Software has well-constructed menu functions, making it possible to use the MC Module easily. The function groups of the MC Module are classified with the system setup menu and the itemized functions of the MC Module are classified with the main menus. These are the main menus of the MC Support Software: MC Program Edit Menu MC Parameter Edit Menu Position Data Edit Menu MC Monitoring Menu MC Program Edit Menu MC Parameter Edit Menu 53  SPECIAL I/O MODULES MOTION CONTROL MODULE Specifications PART NUMBER C200H-MC221 Number of I/O words 20 (2 slots) External connecting devices IBM PC/AT or compatible, Teaching Box, and MPG (manual pulse generator) Controlled driver Servodrivers that can handle analog inputs Control Positioning Control method Semi-closed loop using incremental encoder (speed command voltage output) Number of controlled axes 2 axes max. Number of simultaneously controlled axes 2 axes max. PTP (independent) control Execution by independent programs, operation modes for each axis Linear interpolation 2 axes max. Circular interpolation 2 axes max. on a plane Interrupt inching Inching on an axis with interrupt input to the axis. Speed control Control unit Minimum unit settings 1, 0.1, 0.01, 0.001, 0.0001 (the unit conversion function is not available.) Units mm, inch, degree, pulse Max. command value --39,999,999 to +39,999,999 Acceleration//Deceleration curve Trapezoid or S curve Acceleration/Deceleration time 0 to 9,998 ms in 2-ms units can be set independently for acceleration and deceleration. Feed operations Rapid feed speed Example: 36.86 m/min. Interpolation feed speed Example: 36.86 m/min. Rapid feed override 0 to 100% Interpolation feed override 0 to 199% Conditions Encoder resolution: 2,048 p/r /r Motor speed: 4,500 r/m Control unit: 0.001 mm/pulse Setting unit: 0.1% Jog feed override 0 to 100% Task program rogram managementt Number of tasks 2 max. (program execution units) Number of programs The maximum number of programs differs according to the number of tasks (e.g., 100 programs are controlled if 1 task is used and 50 programs are controlled if 2 tasks are used). Task program management Program capacity The maximum number of program blocks varies with the number of tasks (e.g., 800 program blocks are controlled if 1 tasks is used and 400 program blocks are controlled if 2 tasks are used). Position data capacity 2,000 max. when only 1 axis is used. Number of registers 32 (mainly used to specify position data numbers) Sub-program nesting 5 levels max. M code 0 to 999 Auxiliary function 54 Speed control of up to 2 axes. From 1 to 1,000,000 ppc in single-pulse increments (after quadruplication), if pulses are used as the unit of control. Internal current consumption 0.65 A (0.85 A with Teaching Box connected) at 5 VDC 0.2 A at 24 VDC Weight 500 g max. Manual W314, W315, W256  SPECIAL I/O MODULES MOTION CONTROL MODULE System Configuration C200HX/HG/HE/HS/S PLC MC Support Software (IBM PC/AT or compatible) C200H-MC221 MC Module Manual Pulse Generator (MPG) External input (dedicated cable) Analog Input Servodriver Teaching Console Terminal Block Conversion Unit 2 Axes CCW limit input CW limit input 2 generalpurpose inputs Origin proximity input Servomotor Emergency stop input 55  SPECIAL I/O MODULES POSITION CONTROL MODULE Position control modules provide either a step and direction pulse train or CW/CCW pulse trains to control a single- or dualaxis stepper or servo motor driver. Interface signals include CW and CCW limits, origin approach, origin stop, emergency stop, and interrupt signals. Automatic backlash and origin offset functions are now included for precise positioning requirements. Move parameters can be set up in either ladder logic, or by connecting the hand-held programming console and are stored in battery-backed memory. Extensive diagnostics are also available to the PLC for quick error detection and troubleshooting. Features • Pulse output for stepper motor or servo motor driver C200H-NC211 • Origin and backlash compensation for precision positioning C200H-NC112 • Teach mode or storage of calculated movement parameters • Internal diagnostics • External signal interface for CW, CCW, origin, emergency stop, mode, and interrupt • Parameters, speeds, and positions set in CPU DM area • Linear interpolation capability on C200H-NC211 Additional Functions -- C200H-NC211 Only • Simultaneous two-axis control is possible with single-axis independent control and two-axis linear interpolation. • Position data or speed data can be changed or transferred from the PLC to the NC211 while the positioning operation is stopped. • Speed can be changed using the speed coefficient, even during positioning operation. • Up to 53 positions can be set on both axes. Specifications PART NUMBERS C200H-NC211 C200H-NC112 Axes controlled 2 axes/Module 1 axes/Module Control system Automatic trapezoidal acceleration/deceleration Position Speed Data --8,388,607 to 8,388,606 pulses Data capacity 53/axis Data 1 to 250,000 pps Data capacity 15 Speed adjustment rate Origin search 56 20 2 to 2,000 pps/1 ms Origin proximity None/NO/NC When provided, H/L level selection is available. Origin signal Rise or fall selection Origin compensation 0 to ±9,999 pulses Origin search speed High speed, proximity speed setting available Backlash compensation 0 to 9,999 pulses Manual operation High-speed jog, low-speed jog, inching I/O words required 20 (Special I/O area) 10 (Special I/O area) Internal current consumption 5 VDC, 0.5 A max. 5 VDC, 0.2 A max. Weight 500 g max. 400 g max. Manual W166 W128  SPECIAL I/O MODULES POSITION CONTROL MODULE Connection Example -- Servo Motor for the Pulse-train Input Input Module C200H-NC211 Position Control Module AC Servo Driver C200HX/HG/HE AC Servo Driver  XW2ZJ-A2 Connecting Cable for the C200HNC211 AC Servomotor AC Servomotor XW2B-40J6-2 Connector/Terminal Conversion Unit for the C200HNC211 57  SPECIAL I/O MODULES HIGH-SPEED COUNTER MODULE The high-speed counter modules provide an interface for applications where the counting speed exceeds the PLC’s processing speed. Typical applications include frequency inputs, rotary encoder interface, position control, cut to length, and motion control. Built-in I/O and front panel indicators on the module allow for faster throughput and easy visual monitoring of module status. Interface signals include count inputs, integral outputs, and external resets. Features C200H-CT021 C200H-CT001-V1 C200H-CT002 Two counters count input signals at a high speed of 75 kcps max. (C200H-CT021) from Incremental Rotary Encoders or other sources. Seven counting modes for varied applications: Simple counter mode counts input pulses (available with the C200H-CT021 only) Drum operations linear mode, circular mode Preset counter operations -- preset mode Counting operations -- gate mode (normal and cumulative), latch mode, sampling mode • Three input modes available: differential phases, up/down inputs, pulse and direction inputs • Provided with multiplication function (x2/x4) for differential phase input • Count values can be set in either BCD or HEX Note: A maximum of 16 C200H-CT021 Modules can be mounted to a single C200HX-CPU5 -E, C200HXCPU6 -E, C200HG-CPU5 -E, or C200HG-CPU6 -E CPU.  58     SPECIAL I/O MODULES HIGH-SPEED COUNTER MODULE Specifications PART NUMBER C200H-CT001-V1 Number of axes 1 axis/Module 2 axes/Module Operating modes 6 7 Input signal Encoder inputs A, B Counter 1 inputs A, B Counter 2 inputs A, B Signal level 5, 12, or 24 VDC (selected when wiring) Input modes Differential, up/down, pulse and direction Counting speed (see note) 50 kcps Other Input multiplier (x2 or x4) available for differential inputs Input signal Counter input Z Counter 1: input Z Counter 2: input Z Signal level External control inputs IN1 and IN2 Counter 1: external control inputs IN1 and IN2 Counter 2: external control inputs IN1 and IN2 Count input External input RS-422 line driver (Am26LS31-compatible) Input signal Control inputs IN1, IN2 Signal level 5, 12, or 24 VDC (selected when wiring) Output External outputs 0 to 7 (8 points) Output level External output power supply: 5 to 24 VDC Switching capacity: 16 to 80 mA I/O words required 10 (Special I/O area) Internal current consumption 5 VDC, 0.3 A max. Weight 400 g max. Manuals W141 Note: RS-422 line driver (Am26LS31-compatible) C200H-CT021 12 or 24 VDC (selected when wiring) RS-422 line driver (Am26LS31-compatible) 75 kcps 5, 12, or 24 VDC (selected when wiring) External output C200H-CT002 12 or 24 VDC (selected when wiring) RS-422 line driver (Am26LS31-compatible) 12 or 24 VDC (selected when wiring) 5 VDC, 0.4 A max. 305 g max. W141 W311 Affected by the differential phase pulse input. System Configuration A High-speed Counter Module counts input signals from incremental rotary encoders or other sources.  C200H-CT0 High-speed Counter Module C200HX/HG/HE Rotary Encoder (E6A, etc) Sensor input switch, etc. 59  SPECIAL I/O MODULES CAM POSITIONER MODULE The Cam Positioner Module simulates a rotating mechanical cam, drum sequencer, or programmable limit switch in a PLC I/O module. The module provides a resolver interface and uses the Data Setting Console for displaying values. Features C200H-CP114 C200H-DSC01 Data Setting Console • The cam outputs can be set at 16 external outputs and 32 internal outputs with a total of 48 points. The internal outputs can be taken directly into the C200HX/HG/HE, reducing wiring inside the control panel. • The ON/OFF data for the maximum of seven points can be set for one cam. Data can be registered in one bank. To facilitate easy set-up changes during operation, a maximum of eight banks is available for data setting. • The Data Setting Console allows easy monitoring of cam data settings, present cam angles, or resolver rpm. • To provide an optimum output, use the adjustable operation function to make fine adjustments of the ON/OFF data. • Data on operating conditions -- such as the present cam angle, cam outputs for 48 points, resolver rpm, and resolver status -- can be constantly monitored from the C200HX/HG/HE side. • Using origin compensation, the machine origin and the resolver origin can be easily matched. • The resolver rpm can be converted into an actual production quantity by using the scaling function. Specifications 60 PART NUMBER C200H-CP114 Output points 48 points (16 external output points, 32 internal output points) External outputs NPN transistor open collector (with photo-coupler insulation) Switching capacity: 100 mA at 24 VDC Simultaneous ON points: 8 points max. Resolver cable length 100 m max. Resolver response rpm 800 rpm max. Resolver response speed 200 µs (at a sampling frequency of 5 kHz) Resolver resolution 1° Program memory EEPROM (8 banks) Origin compensation 1° or 359° (The present angle needs to be compensated to 0°) Internal current consumption 5 VDC, 0.3 A max. (Supplied from the Backplane.) External power supply 24 VDC +10%/--15%, 2 A min. Weight 350 g max. Manual W224  SPECIAL I/O MODULES CAM POSITIONER MODULE System Configuration Cam Positioner Module C200HX/HG/HE 3F88L-RS17/17T 3F88L-RS15/15W Resolver Solenoid, DC Input Module, etc. C200H-DSC01 Data Setting Console 61  SPECIAL I/O MODULE ASCII/BASIC MODULE Two RS-232C Ports Bidirectional serial interface to • Computers • Printers • Bar code readers • PLCs • Other ASCII devices The ASCII/BASIC Module provides a 24-Kbyte programmable coprocessor module that operates independently of the PLC. Two built-in RS-232C ports provide easy interface to a variety of external devices including other manufacturers’ PLCs, computer terminals, operator stations, bar code readers, and any other device utilizing a serial interface. The module is programmable in either BASIC or Assembly providing a platform for complex calculations and algorithms at the PLC level. This includes PID, gas flow calculations and complex math and string manipulation functions. Communications can be initiated by either the module or the PLC. C200H-ASC02 Features • 24-Kb, battery-backed RAM and 24-Kb EEPROM programmable in BASIC or Assembly languages • Special commands to initiate communication with the PLC • Two RS-232C ports, 19,200 baud maximum speed • Built-in clock/calendar including year, month, day, date, hour, minute, second (accurate to 30 seconds/year) Specifications 62 PART NUMBER C200H-ASC02 Baud rate Port 1: 300 to 9,600 bps Port 2: 300 to 19,200 bps Transmission distance 15 m max. Memory capacity BASIC program area: 24K bytes (RAM) BASIC program storage area: 24K bytes (EEPROM) Transmission capacity 255 words max. at 20 words per cycle Diagnostic functions CPU watchdog timer, battery voltage drop Battery life 5 years at 25°C (77°F) The life of the battery is shortened if the Module is used at higher temperatures. I/O words required 10 (Special I/O area) Internal current consumption 5 VDC, 0.2 A max. Weight 400 g max. Manual W165  SPECIAL I/O MODULES ASCII/BASIC MODULE System Configuration ASCII/BASIC Module C200HX/HG/HE Port 1 (RS-232C) (RS-232C) (Programming) Port 1/Port 2 (I/O) Keyboard Printer Computer Bar-code reader Modem NT-series Programmable Terminal 63  SPECIAL I/O MODULES VOICE MODULE Use the Voice Module for operator interface messages. Record up to 60 voice messages on site, or use a tape recorder and transfer the messages to the module. Messages can also be uploaded or downloaded through the RS-232C port on the front panel. The built-in speaker enables immediate message verification. Message length and sound quality are selectable. Input Devices • Computer • Microphone • Tape recorder Output Devices • Computer • Printer • Speaker • Microphone jack enables live message broadcast • Flexible message length • Messages can be interrupted to start another message • Messages can be recorded in phrase and word combination formats C200H-OV001 • Upload or download messages through the RS-232C port on the front panel Specifications PART NUMBER C200H-OV001 Voice synthesis method Message Message in input ut (switch (switch-selectable) selectable) Message output (switch-selectable) 32, 48, or 64 s (switch selectable) Capacity (sentences and phrases) 60 max. MIC IN Microphone input: Unbalanced dynamic microphone (600 Ω) LINE IN Tape input: Input impedance: 50 kΩ, unbalanced; Maximum input voltage: 3.3 V SPEAKER OUT Built-in amplifier output: 0.14 W (8 Ω speaker) LINE OUT External amplifier output: 600 Ω unbalanced transformer output Maximum output voltage: 0.5 V rms (effective value) Both balanced and unbalanced external amplifiers can be connected. Built-in monitor speaker Diameter 27 mm, 0.1 W (8 Ω) Input frequency 32-second recordings: 8 kHz 48-second recordings: 5.3 kHz 64-second recordings: 4 kHz Output frequency characteristics 32-second recordings: 100 Hz to 3.2 kHz 48/64-second recordings: 100 Hz to 2.2 kHz Low-pass filter (LPF) selector function (see note) Cutoff frequency: 3.2 kHz for 32-second recordings, 2.2 kHz for 48/64-second recordings Message memory 128K bytes RAM (battery powered) External communication function (for saving recorded messages) RS-232C (Baud rate: 19,200/9,600/4,800/2,400 bps. XON/XOFF: yes/no, CTS/RTS: yes/no) Self-diagnosis function CPU watchdog timer, LOW battery voltage detection Battery life 5 years at 25°C (battery life is shorter for higher temperatures) I/O words required 10 (Special I/O area) Internal current consumption 5 VDC, 0.3 A max. Weight 400 g max. Manual W172 Note: 64 Adaptive differential pulse-coded modulation (ADPCM) Recording time The recording time of the Voice Module is varied by changing the unit’s input frequency. For improved sound quality, the cutoff frequency of the low-pass filter is automatically changed to a lower frequency when the recording time is increased from 32 to either 48 or 64 seconds. (The output frequency is set to 100 Hz to 2.2 kHz when the recording time is set to 48 or 64 seconds.)  SPECIAL I/O MODULES VOICE MODULE System Configuration Voice Module C200HX/HG/HE Voice Output Voice Input Microphone (dynamic, 600 Ω) Module’s internal amplifier output LINE OUT (600 Ω) Speaker (8 Ω, commercially available) Cassette tape recorder (50 kΩ, 3.3 V max., audio use) External amplifier Speaker 65  SPECIAL I/O MODULES RFID SENSOR MODULE The RFID Modules provide a direct interface to Omron’s V600 and V620 C200H RFID Sensor Read/Write Heads. The module acts as the controller for Read/Write Heads that exchange data with data carriers using RF technology. Applications include conveyor and pallet storage, product labeling, warehousing applications, and more. Up to 8 Kb of data can be stored on a single data carrier. The interface modules provide a quick and easy interface to the production line PLC using ladder diagram programming. C200H-IDS01-V1 (electromagnetic, for short distances) C200H-IDS21 (microwave, for long distances) Features • Provide flexibility in handling individual workpieces or pallets by reading product specifications can be read from ID data carriers (tags) • Allows up-to-date access information on inventory and material flow • System consists of an ID controller or SYSMAC C200H-IDS Module, Read/Write (R/W) heads, and data carriers (tags) • Three Read/Write ranges available • Direct monitoring from the C200H-IDS Module with hand-held programming console Specifications PART NUMBER C200H-IDS01-V1 AND C200H-IDS21 Communication control procedure Interactive Number of R/W Heads (antennas) connected One per RFID Sensor Module Data Carrier (DC) 2K-byte SRAM (with replaceable battery), 8K-SRAM (with built-in battery) 256-byte EEPROM Data Carrier memory format 8-bit format Commands The following seven commands are used: Read, Write, Auto Read, Auto Write, Clear-all, Auto Read/Write Abort, and Data Management (C200H-IDS01-V1 only) Data transferrable per instruction Up to 512 words (1024 bytes) can be transferred at 20 words/scan. Diagnostic functions • CPU watchdog timer • Communication errors -- Data Carrier Missing Six communication errors identify the causes of errors that have occurred during communication between the Data Carrier and the RFID Sensor Module • Error Log The Error Log function allows communication errors to be displayed in statistical form or in order of occurrence. Error information is retained by the back-up capacitor. Monitoring functions The following monitoring functions are available when the RFID Sensor Module is connected to a Hand-held Programming Console. Use the keyboard sheet provided with the RFID Sensor Module. (Cable length: 4 m max.) Read (1 byte) Stepwise Write (1 byte) Continuous Write Test Error Log Memory backup Error information is backed up by a capacitor for 15 days (at 25°C). I/O words required 5 (Special I/O area) Internal current consumption 5 VDC, 0.25 A max. 26 VDC, 0.12 A max. (to drive Read/Write Head or R/W Antenna) See note. Weight 400 g max. Manual W153 Note: 66 The Read/Write Head (or Antenna) is supplied 26 VDC. Refer to the C200H PLC Installation Guides (W111 and W218) for information on system design.  SPECIAL I/O MODULE RFID SENSOR MODULE System Configuration C200H-IDS01-V1 RFID Sensor Module C200HX/HG/HE Data can be read from or written to a moving DC. C200H-CN422 (4 m) C200H-CN222 (2 m) Connecting Cable V600 Read/Write (R/W) Head (Antenna) Special keysheet for RFID Sensor Module  C200H-PRO27-E Programming Console V600-D Data Carrier (DC) Tests data transmission and reads out error messages.  Further details on RFID components can be found in Catalog Q80-E3- . 67  68 COMMUNICATIONS COMMUNICATIONS Overview Communication Modules Fiber-optic Cable and Connections 69 70 72 89 69  COMMUNICATIONS OVERVIEW Plant-wide Information Management and Control Networks Omron’s advanced plant-wide information management network capabilities let you harness the power of valuable manufacturing and production data stored throughout your plant and turn it into a competitive advantage. Omron’s ethernet connectivity allows customers to interface PLCs with higher level business computing systems and other PLCs via Ethernet. To link your supervisory computers and factory controllers in a seamless, high-speed, high-capacity network, use Omron’s fiber-optic based SYSMAC NET communications network. Twin fiber-optic cables, automatic loopback, and a token ring configuration provide a reliable, deterministic interface to a variety of information systems. SYSMAC NET’s fast, 2 Mbps transmission speed and 2 Kb message size moves large amounts of data quickly. Distributed Control Networks By more tightly integrating their control systems, many manufacturers have been able to increase productivity and manufacturing flexibility. Omron’s SYSMAC LINK distributed control network provides a high speed (2 Mbps) link for exchanging critical production data between supervisory computers and programmable controllers in real time. The token bus peer-to-peer network uses noise resistant fiber-optic or low cost co-axial cable media for reliable, deterministic communications. A special data link feature provides an easy to set up, shared memory system for even tighter integration between multiple controls and computers. Operator Interface Terminals on Networks Omron’s Host Link serial network provides an ideal interface for today’s data-hungry data acquisition and control software, or local operator interface. Multiple Operator Interface Terminals can be connected to a PLC using the Host Link module. Drivers for this openly available protocol have been developed for all major third-party operator interface and control software packages and operator interface devices. Device-level Networking Omron offers several options for the networking to factory floor devices. Omron’s DeviceNet products are compatible with the DeviceNet specification and provide a variety of distributed I/O solutions. DeviceNet is an open communications protocol that allows several vendors’ products to exist on a single network, giving the customer a wide variety of options to choose from. Omron’s SYSMAC Bus remote I/O systems significantly lower wiring and maintenance costs. The SYSMAC Bus remote I/O connects CPUs and distant I/O using low-cost twisted pair wiring or fiber-optic cables. 70  COMMUNICATIONS OVERVIEW PLANT INFORMATION SYSTEM Ethernet CV 500 C200HX/HG/HE Bridge PLANTWIDE INFORMATION SYSMAC NET MMI computer C2000H Line Server MMI computer C200H DISTRIBUTED CONTROL CV/CVM1 SYSMAC LINK C200HX/HG/HE CV1000 CV1000 MMI computer Master C200HX/HG/HE SYSMAC BUS Wired System Slave I/O Blocks C200H Remote Rack C500 Remote Rack DeviceNet System Remote I/O Block CQM1-DRT21 Branching SYSMAC BUS Fiber-optic System C500 Remote Rack C200H Remote Rack Fiber-optic Remote I/O Block Dedicated cable Trunk line Manifold Valve Block I/O Control Station Bar Code Reader RS-232C Interface DeviceLink Cable Third-party Products 71  COMMUNICATIONS MODULES PC CARD MODULES Connect to ethernet networks with ease and exchange data files using PCMCIA cards. The PC Card Module provides two PCMCIA interface slots. Two type-I or type-II cards or one type-III PCMCIA card can be installed. Using the C200HWPCU01-E, C200Hα memory contents may be written to memory cards as files, to exchange production data between PLCs and PCs. Using the C200HW-PCS01-E with an Ethernet-compatible PCMCIA card, data may be exchanged using FINS protocol via UDP/IP. C200HW-PCU01-E PC Card Module Features C200HW-PCS01-E Ethernet Set (setup utility driver provided) Data storage and ease of production stage change with Memory Cards. • A standard SRAM or FLASH card inserted into the slot is used as file storage • Data can be loaded and saved between the PLC and memory cards using CMCR (CARD MACRO) instructions • Data written with the PC Card Module to memory cards is read with the IBM PC/AT or compatible and vice versa Communications Board C200HW-COM01 C200HW-COM04-E (with RS-232C port) Connects to Office Networks with Ethernet Cards • A standard Ethernet Card can be inserted into the slot and, using the RS-232C port on the front panel, can be set to allow connection of the C200HX/HG/HE PLC with the Ethernet • Data is loaded and saved between the CPU and host computer by using OMRON’s unique FINS (Factory Intelligent Network Service) commands. In addition, the PC Card Module allows the PLC to execute the SEND/RECV instruction to communicate with the host computer or other PLCs. Bus Connection Unit C200HW-CE011 (for 1 Module) C200HW-CE012 (for 2 Modules) PC Card Module Specifications PART NUMBER C200HW-PCU01-E CPU i80386-SX25 MHz Memory 1 MB DRAM ROM 512 KB (for BIOS, DOS, and system file storage) FLASH ROM 1 MB (for BIOS, DOS, and system file storage) Serial port RS-232C x 1 (for terminal connection setup) PC card interface PCMCIA 2.1 (3.3-V type is not supported.) Type  x 2 slots or type  x 1 slot Indicators RUN, ERR, PC card access, and PC card formatting Power supply 5 VDC (supplied by the Power Supply Unit) Dimensions 34.5 x 130 x 125 (W x H x D) Weight 400 g max. Note: 72 I80386 is a registered trademark of Intel Corp. Ethernet is a registered trademark of Xerox, Corp.  COMMUNICATIONS MODULES PC CARD MODULE System Configuration Data Storage and Easy Production Stage Changes using Memory Cards C200HX/HG/HE PC Card Module Communications Board Peripheral devices such as Temperature Controller, etc. Memory card IBM PC/AT or compatible Connects to OA Networks using Ethernet Cards Production order data Host computer Ethernet CV-series PLC Production order data CV500-ETN01 Ethernet Module C200HX/HG/HE Ethernet Set and PC Card Module Recommended Memory Cards MANUFACTURER PRODUCT SunDisk compatibles SDP5100A (FLASH PACKER series) Intel IMC001FLKA (FLASH Card) Note: OMRON does not guarantee the performance of the above memory cards although OMRON has confirmed that the above memory cards are suitable for the PC Card Module. Recommended Ethernet Cards MANUFACTURER PRODUCT Kingston Technology KNE-PCM/T Others ODI SPEC3 Compatible 73  COMMUNICATIONS MODULES PC CARD MODULE Possible Configurations When Installing PC Card Modules Standard Mounting -- for PC Card Module C200HW-CE011 Bus Connection Unit (for 1 Module) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200HWPCU01--E PC Card Module C200HW-COM01/04-E Communications Board C200HW-PCS01-E Ethernet Set Mounting with the SYSMAC LINK Module C200HW-CE012 Bus Connection Unit (for 2 Modules) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200HW-PCU01-E PC Card Module C200HW-PCS01-E Ethernet Set C200HWSLK13/23/14/24 SYSMAC LINK Module 74 C200HW-COM01/04-E Communications Board  COMMUNICATIONS MODULES SYSMAC NET LINK MODULE SYSMAC NET is a fiber-optic token ring network designed to transfer large amounts of data between the PLC and IBM PC/AT Compatible, VME computers, and any ASCII RS-232C devices. Fiber-optic transmission media provides reliable long distance communications in harsh environments. Automatic loop-back, extensive diagnostics, and network utility software provide added reliability and ease of configuration. The C200HS-SNT32 SYSMAC Module is easily integrated to the C200Hα CPU. The Module connects to the CPU through one of the C200HWCOM01/COM04-E Communications Boards with a C200HWCE001/CE002 Bus Connector. C200HS-SNT32 Features • Achieves high-speed and long-distance communications through Fiber-optic Cables -- N:N token ring communications method is available. Transmission is possible with a node separation of 1 km and a data transmission rate of 2M bits/s. Transmission up to 3 km is possible when a long-distance repeater is connected. • Large-scale FA Network configuration -- Up to 126 NSB, NSU, and SYSMAC NET Link Modules can be connected. Connect the PLC to a factory computer or host computer network. • Improved redundancy capabilities -- The automatic loop-back and node separation test facilitate the taking of prompt countermeasures when any abnormality occurs. Communications Board C200HW-COM01 C200HW-COM04-E (w/RS-232C port) Bus Connection Unit C200HW-CE001 (for 1 Module) C200HW-CE002 (for 2 Modules) • Easy data links between PLCs -- The built-in application software allows easy data links between PLCs. • Compatible with H-PCF Fiber-optic Cables -- Possible to use not only the conventional PCF fiber optic cables but also H-PCF (hard-clad fiber) Cables. Since solderless optical connectors can be used, connections on-site have become easier. (For detailed specifications and ordering procedures for H-PCF Cables, contact your OMRON representative.) Optional Power Supply Module The SYSMAC Net Module is designed to receive back-up power supply from the Optional Power Supply Module. Should any failure of the SYSMAC Net Module occur, the node bypass function will activate to prevent shutdown of the entire network. Communication Specifications ITEM DESCRIPTION Communications method N:N token ring Transmission method Manchester code, base band Data transmission rate 2M bps Transmission paths 2-conductor fiber optic cable (plastic-clad, crystal core; core dia.: 200 µm) Number of nodes 126 max. Node separation 1 km max. Message length 2K bytes max. Send buffer capacity 1 message Receive buffer capacity 15 messages Redundancy functions Automatic loopback Node bypass Self-diagnosis function (by test mode function) Error detection CRC-CCIT generating function = X16+X12+X5+1 Optional Power Supply Module C200H-APS01 (for 1 Module C200H-APS02 (for 2 Modules) (Optional Power Supply Adapter required) Power Supply Connecting Cable C200H-CN001 (for 1 Module) C200H-CN002 (for 2 Modules) 75  COMMUNICATIONS MODULES SYSMAC NET LINK MODULE Network Configuration The SYSMAC NET consists of one line server and a combination of 126 NSB, NSU, and SYSMAC NET Link Modules max. IBM PC/AT or compatible NSB SYSMAC NET Host computer IBM PC/AT or compatible ASCII Module RS-232C Line server NSB C-series PLC RS-232C Optical fiber cable (2-core) NSU Central Power Supply SYSMAC NET Bridge NSB IBM PC/AT or compatible Power Supply Adapter SYSMAC NET Link Module SYSMAC NET Link Module C200HX /HG/HE C500 C1000H C2000H Back loop Normal loop NSB: Network Service Board NSU: Network Service Module Bridge: Used for connecting two networks. Up to 20 bridges can be connected in one network provided that it is treated as one node. SYSMAC NET Link Module: Treated as one node. (It doesn’t function as a bridge. When used together with the SYSMAC LINK Module, only a total of two Modules can be connected.) Specifications 76 PART NUMBER C200HS-SNT32 Transmission direction 1:1 1:N Data length 1,000 words max. (2,000 bytes) Only in the same area Send/Receive data to/from PLC The command/response format data for data send or that for data receive are sent/received if SEND(90) or RECV(98) has been executed by the program instruction. Send/Receive data to/from Module other than PLC Command/Response by data send or data receive Watchdog timer response 1 s (default) or watchdog timer setting value (10 min, 55.35 s max.) Internal current consumption 1 A max. Weight 400 g max. Manual W114 Data send/receive Data send only (no response) Broadcasting data transfer: N:126 max.  COMMUNICATIONS MODULES SYSMAC NET LINK MODULE Possible Configurations When Installing SYSMAC NET Link Modules The following are the possible configurations for installing a SYSMAC NET Module on a C200Hα CPU Rack. One Module Mounted C200HW-CE001 Bus Connection Unit (for 1 Module) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200H-APS01 Power Supply Adapter (for 1 Module) C200HW-COM01/04-E Communications Board C200HS-SNT32 SYSMAC NET Link Module Two Modules Mounted C200HW-CE002 Bus Connection Unit (for 2 Modules) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200H-APS02 Power Supply Adapter (for 2 Modules) C200HS-SNT32 SYSMAC NET Link Module C200HW-COM01/04-E Communications Board With SYSMAC LINK Module C200HW-CE002 Bus Connection Unit (for 2 Modules) C200H-APS01 Power Supply Adapter (for 1 Module) C200HS-SNT32 SYSMAC NET Link Module Note: C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200HW-COM01/04-E Communications Board C200HSSLK13/23/14/24 SYSMAC LINK Module Up to two SYSMAC LINK Modules and the SYSMAC NET Link Module can be mounted to the left of the CPU. 77  COMMUNICATIONS MODULES SYSMAC LINK MODULES SYSMAC LINK is a fiber-optic token ring network designed to transfer large amounts of control data in real-time between PLCs. Both coaxial and fiber-optic medias may be used. The C200Hα SYSMAC Link Modules are easily integrated to the C200Hα CPU. The Modules connect to the CPU through one of the C200HW-COM01/COM04-E Communications Boards with a C200HW-CE001/CE002 Bus Connector. Features C200HW-SLK23/24 (Coaxial cable) C200HW-SLK13/14 (Fiber-optic) • Maximum of 62 SYSMAC LINK Modules -- Up to 62 SYSMAC LINK Modules can be connected in one network. In addition, two SYSMAC LINK Modules can be mounted on one PLC, allowing multi-level system configuration. • Data Modules -- The data link capacity is as large as 2,966 words. High-speed and large-capacity data communications are possible using the LR area and DM area. • Flexible Data Link configuration -- Since an optimum data link table can be created for each node (Machine No.) using the SYSMAC Support or SYSWIN, the data link area can be used effectively. Communications Board C200HW-COM01 C200HW-COM04-E (w/RS-232C port) Bus Connection Unit C200HW-CE001 (for 1 Module) C200HW-CE002 (for 2 Modules) • Event communications -- using the SEND and RECV instructions, up to 256 words of data can be sent or received for any node in the network. • Remote programming or monitoring using the SYSMAC Support Software -- Programs can be transferred to any SYSMAC Module within the network and various monitoring operations can be performed for that Module. • Built-in LSI exclusively for communications -- The built-in LSI allows setting of the communication time period between SYSMAC Modules. The control station is automatically switched when any trouble occurs in the data link control station, assuring a highly reliable data link system. Optional Power Supply Module The SYSMAC Link Modules are designed to receive back-up power supply from the Optional Power Supply Module. Should any failure of the SYSMAC Link Module occur, the node bypass function will activate to prevent shutdown of the entire network. C200H-APS03 Optional Power Supply Module 78 Note: Mount the SYSMAC LINK Module to the left of the CPU. The SYSMAC LINK Module cannot be used with the C200HE-CPU11-E.  COMMUNICATIONS MODULES SYSMAC LINK MODULES Specifications PART NUMBER C200HW-SLK23/24 (COAXIAL) Communications method N:N token ring C200HW-SLK13/14 (FIBER OPTIC) Transmission method Manchester code, base band Transmission path Bus Data transmission rate 2M bps Transmission media Coaxial cable (5C-2V) Hard-plastic-clad quartz optical fiber cable Node separation 1 km max. 10 km max. (800 m max. between nodes) Message length 512 bytes max. (256 words) Connectors BNC (F Adapter) Link functions Data link, data read/write service Data link words C200HW-SLK13/23: 918 words max. C200HW-SLK14/24: 2,966 words max. Send buffer capacity 1 message Receive buffer capacity 2 messages RAS functions Automatic polling unit backup, self-diagnostics (internode echo tests), failed node bypass (optical systems only), watchdog timer, error (CRC-CCITT) detection = X16+X12+X5+1 Current consumption 0.8 A max. Weight 400 g max. Manual W174 Daisy chain Full, half-lock press-in connector 500 g max. System Configuration Coaxial Cable System Up to 62 nodes separated by a total of 1 km max IBM PC/AT or compatible C200HX/HG/HE C1000H-TER01 Termination Resistance is necessary CVM1 CV500/CV1000/CV2000 SYSMAC LINK Support Board 3G8F5-SLK21-E C1000H-TER01 Termination Resistance is necessary 79  COMMUNICATIONS MODULES SYSMAC LINK MODULES Fiber-optic System Up to 62 nodes separated by a total of 10 km max. with 800 m max between nodes CVM1 CV500/CV1000/CV2000 C200HX/HG/HE IBM PC/AT or compatible C200H-APS03 Backup Power Supply Module (see note 1) Uninterruptible Power System (see note 3) Note: C1000H-APS01 Backup Power Supply Module SYSMAC LINK Support Board 3G8F5-SLK21-E Backup Power Supply (see note 2) 1. The Backup Power Supply is provided with Power Supply Cables (C200H-CN111, C1000H-CN111 for one Module). When supplying power to two Modules simultaneously, order the C200H-CN211 Cable for one Module. 2. The Backup Power Supply Module for a PLC is different in shape from that for a IBM PC/AT or compatible. Be sure to use an appropriate Power Supply. 3. The Backup Power Supply must be separated from the main power supply line to the PLC. Possible Configurations When Installing SYSMAC Link Modules One Module Mounted C200HW-CE001 Bus Connection Units (for 1 Module) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200HW-COM01/04-E Communications Board C200HW-SLK13/23/14/24 SYSMAC LINK Module Two Modules Mounted C200HW-CE002 Bus Connection Unit (for 2 Modules) C200HE-CPU32-E/42-E C200HG-CPU33-E/43-E/53-E/63-E C200HX-CPU34-E/44-E/54-E/64-E CPU C200HW-COM01/04-E Communications Board C200HW-SLK13/23/14/24 SYSMAC LINK Modules 80  COMMUNICATIONS MODULES DEVICENET SCANNER MODULE The DeviceNet Scanner Module for the C200Hα allows open communication over DeviceNet networks with Omron and other vendors’ I/O products. DeviceNet’s open communications protocol allows the greatest flexibility in design of distributed I/O, while at the same time reducing installation costs. Features • Dedicated cable saves wiring effort -- two nodes are connected through a single dedicated cable, greatly reducing installation costs • Allows T-type bifurcation, branching, and multi-drop wiring. • Connects to 50 slaves max. for 1,600-point I/O control possible with the C200HX-, C200HG-, and C200HE-series Master C200HW-DRM21 • Network length of 500 meters max. -- possible with a speed of 125K bps • Communication at 500K bps max. -- possible with a network length of 100 m max. • Conforms to DeviceNet specifications DeviceNet Communications Specifications The communications specifications of the DeviceNet Master Module conform to the DeviceNet communications protocol. ITEM SPECIFICATIONS Baud rate 500K, 250K, or 125K bps (selectable) Communications distance Communications speed (K bps) Max. network length (m) Branch length (m) Total branch length (m) 500 100 max. 6 max. 39 max. 250 250 max. 78 max. 125 500 max. 156 max. Error control CRC, node address multiple check, and scan list collation Cable Dedicated cable Specifications PART NUMBER C200HW-DRM21 Available PLC C200HX/HG/HE Max. No. of connecting PLCs 1 Mounting position Mounted to the CPU or Expansion I/O Rack. (Cannot be mounted to the Slave Rack) Max. no. of I/O points 1,600 Max. no. of connecting slaves 50 Manual W267 81  COMMUNICATIONS MODULES DEVICENET SCANNER MODULE System Configuration Example Master (800 inputs/800 outputs) C200HX/HG/HE Slave DRT1-HD16s DRT1-ND16X Sensor Terminal (8 sensor input points) DRT1-DA02 Analog Output Terminal (2 output points) DRT1-AD04 Analog Input Terminal (4 or 2 input points) DRT1-1D08/16 DRT1-OD08/16 Remote I/O Terminal (8 or 16 input and 8 or 16 output points) DRT1-1016X DRT1-0016X Remote Adapter (16 input and 16 output points) I/O Block SYSMAC CQM1 Branching CQM1-DRT21 (16 inputs, 16 outputs) T-type bifurcation T-type bifurcation T-type Bifurcation Tap T-type Bifurcation Tap Trunk line Dedicated cable Other companies’ products Manifold Valve Block I/O Control Station RS-232C Interface Bar Code Reader DeviceLink Cable T-type Bifurcation Tap (with termination resistor) 82  COMMUNICATIONS MODULES REMOTE I/O MASTER MODULES The SYSMAC BUS Remote I/O system is ideal for distribution of I/O and other devices at long distances from the CPU. Multiple remote I/O systems can be connected to a single CPU allowing maximum configuration flexibility. A SYSMAC BUS Remote I/O system consists of a Remote Master and one or more Remote Slave modules. Both small and large rack-style I/O can be mixed in the same remote I/O system. Remote terminal blocks allow for distribution of 8- and 16-point I/O blocks in a wired remote I/O system. Stand-alone fiber-optic I/O modules allow distribution of 8-point I/O blocks in a fiber-optic remote I/O system. I/O Link modules allow connection of a PLC to a fiber-optic remote I/O system. Special link adapters are available for extended distances and mixing media types. Fiber-optic Master C200H-RM001-PV1 Wired Master C200H-RM201 Features • High-speed distribution with twisted pair wiring (saving both wiring efforts and time) or select fiber-optic cable versions • Variety of I/O styles and types in a given remote I/O system • RS-485 communications at 187.5 Kbps • Connect C200H I/O, C500 I/O, G7 remote I/O terminals, programmable terminals Note: Remote I/O Master Module cannot be used with a DeviceNet Master Module. Available Remote I/O Slaves MODULE Remote I/O Slave Modules C200H Slave Racks WORDS ALLOCATED MAX. IN FIBER-OPTIC SYSTEMS IR 050 to IR 099 5 (any Expansion I/O Racks connected to Slave Racks must be counted as one additional Slave each) C500 Slave Racks Fiber-optic I/O Module Programmable Terminals MAX. IN WIRED SYSTEMS 2 (If C200H and C500 Slave Racks are both used under the same Master, compute the total for C200H Slaves, counting each C500 Slave as two C200H Slaves.) IR 200 to IR 231 32 Cannot connect. Cannot connect. 8 (4 words allocated to each) I/O Terminals 32 (1 word allocated to each) Remote Interfaces 32 (1 word allocated to each) CQM1 8 (4 words allocated to each) Note: I/O links created to C200H ( (See note) When using the above Modules in combination, be careful not to allocate the same words. 83  COMMUNICATIONS MODULES REMOTE I/O MASTER MODULES I/O Links to the CQM1 C200HX/HG/HE with C200H-RM201 Master Set to #0 at the CQM1 CQM1 with I/O Link Module (CQM1-LK501) IR 200/201 Output IR 001/002 IR 202/203 Input IR 100/101 The CQM1 allocates I/O words according to the slot the I/O Link Module is mounted to. System Configuration Fiber-optic Remote I/O System C200H-RM001-PV1 Fiber-optic Remote I/O Master Module Wired Remote I/O System (Maximum of two Modules can be mounted.) C200H-RT001-P/RT002-P Remote I/O Slave Module (Maximum of two Modules can be C200H-RM201 Wired Remote I/O mounted.) Master Module Slave Rack 1-V2 1-V2 C200H-BC Backplane C500 Slave Rack (Calculate one C500 Module as two C200HX/ HG/HE Modules) Fiberoptic Cable C200H-RT201/RT202 Remote I/O Slave Module Slave Rack C200H-BC Backplane 5 Slave Racks max., C500 Slave Rack counted as 2. C500 Slave Rack (Calculate one C500 Module as two C200HX/ HG/HE Modules) Twisted-pair cable C500-RT001/002-(P)V1 Remote I/O Slave Module 5 Slave Racks max., C500 Slave Rack counted as 2. C500-RT201 Remote I/O Slave Module G7TC I/O Block G71 I/O Interface I/O Link Module 32 Module (32 words) max. Terminator G72C I/O Terminal To other Slaves (PTs, I/O Link Modules, etc.) Fiber-optic I/O Module Repeater Module Fiber-optic I/O Module 64 Modules (32 words) max.; Repeater Module not counted and required for more than 32 Modules. 84  COMMUNICATIONS MODULES HOST LINK MODULES Host Link allows any computer or other communications devices to communicate with one (RS-232C), or several (RS-422) Omron PLCs. Multiple system levels can be connected to the same PLC with up to 32 PLCs connected to one computer. Omron’s Host Link protocol is well defined and available for custom software driver development and operator interface connection to Omron PLCs. Most major operator interface companies have Host Link interfaces and drivers available. Host Link systems allow SYSWIN Programming Software or SSS to program and monitor any PLC in the system. When configuring a Host Link system: • The computer must have one serial port available • If a fiber-optic, or RS-422 Host Link module is used, Link Adapters must be included in the system C200H-LK101-PV1 Host Link Module (Fiber-optic) Features The Host Link protocol is common to all Omron PLCs, including the CPM1, CQM1, C200H, C200HS, C200HE, C200HG, C200HX, C1000H, C2000H, and CV-series PLCs. • Connect up to 32 PLCs to a single host computer • Use twisted pair or fiber-optic transmission media On the Host Link Module side: • IR area can be read or written • Programs can be uploaded or downloaded • Up to two Host Link Modules can be connected to a CPU or Expansion I/O Module. RS-232C, RS-422, and plastic-clad fiber-optic are available C200H-LK202-V1 Host Link Module (RS-422) • Host Link Modules can be used in combination (multi-drop) with other C-series Modules • Host Link Modules can be connected to the Operator Interface Terminal C200H-LK201-V1 Host Link Module (RS-232C) 85  COMMUNICATIONS MODULES HOST LINK MODULES System Configuration Multilevel Host Link System The following example illustrates the use of the C200H-LK101-PV1 (fiber-optic) with two personal computers for system monitoring and data loading. Fiber-optic Cable Fiber-optic Cable Two Host Link Modules 3G2A9-AL004-PE Link Adapter RS-232C Host Link Module RS-232C Fiber-optic Cable Host computer (IBM PC/AT or compatible) for system monitoring Host computer (IBM PC/AT or compatible) for data management 3G2A9-AL004-PE Link Adapter Host Link System with SYSMAC Support Software or SYSWIN Various functions, such as offline programming or online monitoring, can be developed by connecting to the IBM PC/AT or compatible with the use of SYSMAC Support Software or SYSWIN. RS-422 3G2A9-AL004 Link Adapter RS-232C Host computer (IBM PC/ AT or compatible) with the C500-ZL3AT1-E SYSMAC Support Software, or SYSWIN C200H-LK202-V1 (as an example) 86  COMMUNICATIONS MODULES PC LINK MODULES PC Link is a peer-to-peer communication system allowing highspeed transfer of data between PLCs over long distances. Both small and large rack PLCs can be connected to the same system. Standard Link Adapters are available for fiber-optic media and longer transmission distances. No special programming is required to transfer data, and multi-level systems can be connected to a single PLC. Features • High-speed data transfer between up to 32 PLCs • No special programming required C200H-LK401 PC Link Module • Multi-level capability Specifications PART NUMBER C200H-LK401 Communication method 2-conductor, half duplex Synchronization HDLC Transmission speed 128K bps Transmission method Broadcasting Transmission distance 500 m (total cable length in system without optical links, including branch lines) Max. no. of PLC Link M d l per S t Modules System (see note) PLC of polling unit Single-level Multilevel C200HX/HG/HE, C1000H, or C2000H 32 16 Transmission LR bits No. of PC Link Modules 2 3 to 4 5 to 8 9 to 16 17 to 32 C200HX/HG/HE, C1000H, or C2000H 512 256 128 64 32 Transmission time 35 ms max. (for 128 bits with 8 PLC Link Modules) Diagnostic functions CPU watchdog timer, CRC transmission error check Interface RS-485 Cable used Shielded twisted pair Manual W135 Note: Use a 3G2A5-LK009-V1 PLC Link Module when connecting to the C1000H(F) or C2000H. 87  COMMUNICATIONS MODULES PC LINK MODULES Multi-level System (4 Levels Max.) PC Link System Hierarchy Level 1 Level 3 PC link PC link PC link PC link PC link PC link PC link PC link PC link PC link PC link PC link PLC PLC PLC PLC PLC PLC PLC PLC PLC PLC PLC PLC PLC link PLC link Level 2 Use a Link Adapter. Use RS-232C, RS-422, or fiber-optic cable depending on application. Level 4 PC link PC link PC link PC link PC link PC link PC link PC link PLC PLC PLC PLC PLC PLC PLC PLC PC link Usage of Link Relay Area PLC #0 LR area Own area Machine #1 data input area Machine #2 data input area Machine #n data input area PLC #1 LR area Machine #0 data input area Own area Machine #2 data input area Machine #n data input area PLC #2 LR area Machine #0 data input area Machine #1 data input area Own area Machine #n data input area PLC #3 LR area Machine #0 data input area Machine #1 data input area Machine #2 data input area Own area Own area becomes the write area (send) for the other machine. Read (Receive) Write (Send) Own LR Other machine’s LR Other machine’s LR Own LR Read (Receive) Write (Send) For example, when inputting data 5232 into LR 00 of machine #0, the data 5232 is output to the LR 00 of machines #1 to #n. Application Example C200HX/HG/HE CPU Rack PC Link -- offering high-speed peer-to-peer communications between PLCs. • Up to two PC Link Modules can be connected to the C200HX/HG/HE CPU C200H--LK401or Expansion I/O Module. C200HX/HG/HE Expansion I/O Rack • The PC Link Module is included in the connectable number of Special I/O Modules (10 Modules max.). Although this requires Machine No. setting, it doesn’t occupy the IR area or DM area. • Using the split processing of the PC Link Module, PC Link service can be divided into two, four, or eight parts, preventing any increase in the cycle time. 88  COMMUNICATIONS FIBER-OPTIC CABLE AND CONNECTIONS Omron pioneered the use of fiber-optics for factory floor communications in 1985 by introducing standard fiber-optic interfaces for Remote I/O and all Omron industrial communications networks. Fiber-optic communications offer distinct advantages over conventional wiring, including electrical noise immunity and increased transmission distances. Recent developments in fiber-optic and communications technology have provided a variety of cost-effective and easy-to-install solutions. Simple field termination, lower cable costs and a variety of fiber-optic cable types allow the effective use of fiber-optic communications in most industrial applications. Omron offers a variety of standard direct-connect fiber-optic modules for fiber-optic communications. Two types of modules are available: -P suffix types are for use with APF, HPCF and PCF Cable types. Non -P suffix types are for use with HPCF and PCF Cable types. Both of these module types accept the fiber-optic cable directly. No adapter is needed. All Plastic Fiber (APF) All Plastic Fiber is ideal for short transmission distances up to 20 meters in remote I/O, or Host Link communications. Field termination requires no special tools or skills. APF requires the use of -P modules. The connectors used with APF are the 3G5A2 connectors. APF Hard Plastic-clad Fiber (HPCF) Hard Plastic-clad Fiber has a 200 micron core cable for maximum distances of up to 200 meters without repeaters. It is available in both a zipcord style and a reinforced plastic-jacketed style with stress relief for pulling through conduit. A termination tool kit is required for field terminations. Bulk cable lengths up to 1 km are available. The connectors used with HPCF are the S3200 connectors. HPCF Zipcord HPCF Reinforced 89  COMMUNICATIONS FIBER-OPTIC CABLE AND CONNECTIONS Plastic-clad Fiber (PCF) Plastic-clad Fiber is a high performance fiber allowing maximum distances of up to 800 meters (0.5 mile) without repeaters. Pre-terminated lengths from 0.1 to 800 meters are available. Connector bodies can be easily removed for running cable through ducts, then re-assembled. PCF Indoor All Glass Crystal Fiber (AGF) Special cable and configurations are available for longer distance requirements, up to 3 km. The maximum transmission distance with each type of fiber-optic cable is determined by the kind of Remote I/O or Host Link modules used. These modules either have a -P or no -P in the part number. The table below shows maximum transmission distances. Longer distances are possible using standard repeaters. PCF Indoor/Outdoor System Compatibility The following table shows which Fiber-optic Cable can be used with each system. The table also shows the maximum length of each Cable. FIBER-OPTIC CABLE APF HPCF PCF SYSMAC BUS with -P modules 20 m (65 ft.) — 100 m (328 ft.) 200 m (656 ft.) 100 m (328 ft.) 200 m (656 ft.) 800 m (0.5 mile) 200 m (656 ft.) 800 m (0.5 mile) 200 m (656 ft.) 800 m (0.5 mile) 1000 m (0.62 mile) SYSMAC BUS with non -P modules SYSMAC WAY with -P modules (C-series only) SYSMAC WAY with non -P modules (C-series only) SYSMAC NET 20 m (65 ft.) — — A Part Number Summary of Fiber-optic Cable and Connectors Refer to the Standard Parts section of this catalog for an inclusive list of Fiber-optic Connectors and Fiber-optic Cable in three basic types (offering numerous selections within each type). 90 PROGRAMMING PROGRAMMING Programming Software SSS and SYSWIN Protocol Support Software Programming Peripherals and Cables Programming Instructions 91 92 94 97 99 91  PROGRAMMING SOFTWARE SYSWIN OR SSS Overview of Software Options C200Hα CPUs can be programmed using Omron’s SYSWIN Programming Software. SYSWIN is a Microsoft Windows-based programming and documentation application. SYSWIN provides you with an easy and intuitive graphical user interface designed for use with all of Omron’s C and CV series PLCs. SYSWIN also offers a comprehensive range of functions for the PLC programmer, from program editing to full symbolic and network debugging. System Information PLCS SUPPORTED CPM1, C**K, C**H, CQM1, C200H, C200HS, C500, C1000H, C2000H, C200HE, C200HG, C200HX, CVM1+EV Communications SYSMAC NET, SYSMAC LINK, HOST LINK Computer requirements 486DX2/50 RAM Capacity 2 or 4 MB RAM minimum Free disk space 8Mb of free hard disk space Floppy disk drive 3.5” double density Communication port 1 or 2, with RS--232C port or RS--422 Video Color VGA or better C200Hα CPUs can also be programmed using Omron’s SSS DOS programming packages. Save time with Easy and Intuitive Programming SYSWIN provides you with fast and easy programming operations. With simple point and click editing, creating ladder logic is a snap. Not sure about which function to use? SYSWIN provides you with a quick categorization of PLC functions and extensive on-line help. First time users will find it easy to learn while working with Omron’s PLCs and Software. Powerful Editing Extensive editing features of SYSWIN lets you create and modify programs quickly and easily. Cut and paste library functions let you take advantage of your existing code. In addition, you can easily find and replace program addresses and documentation throughout your program. 92  PROGRAMMING SOFTWARE SYSWIN OR SSS Documentation Need to document your program? SYSWIN gives you lots of room for commenting addresses (30 characters), networks, and blocks of programs (up to 32K per). In addition, managing your documentation is easy using the Address Symbol Editor. With the Address Symbol editor you get all of our internal relays already documented as well as a summary of all addresses used in the program and documentation. Simply select a new address for your program and choose from the documentation. In addition you can sort your documentation by address or symbol. Extensive Monitoring Tools SYSWIN programming software let’s you monitor bit status, specified I/O status, word content, or Data memory on-line. With the Data Display, monitoring large areas of memory is made easy. Different areas of memory can be monitored simultaneously -- as well as in different data formats, such as hex, decimal, binary, ASCII, and floating point. Powerful Cross Reference SYSWIN’s address cross referencer is great tool for debugging your program. With a simple point and click you can view all your addresses, location and usage while also viewing ladder logic. Then simply click on any address and your ladder logic automatically moves to the location of address. 93  PROGRAMMING SOFTWARE PROTOCOL SUPPORT SOFTWARE Overview The C200HW-COM04-E, C200HW-COM05-E, and C200HW-COM06-E Communication Boards have a protocol macro capability. The Protocol Support Software makes it possible to customize communication sequences by using the protocol macro. The Protocol Support Software supports seven types of standard communications sequences -- to either customize or use as they are. • The conversational-type menu of the Protocol Support Software allows communication sequences to be registered easily. • The Protocol Support Software allows a maximum of 1,000 communication sequences to be registered, each having 16 steps max. • Each of the registered communication sequences can include data for the transmission method, link word, monitor period, and response advice method to be used with the registered communication sequence. X-ON and X-OFF flow control, RS and CS flow, modem control, delimiter control and the contention method are supported by the Protocol Support Software. • Each of the steps can include data for the repetition number, a communication command, communication message, reception matrix, the next process to be executed, and the error processing command to be executed if the step has an execution error. • Any destination address or communications data set with the Protocol Support Software can include variable N, wildcard, and word call settings. Whenever a step is repeated, the value of variable N in the step will increase by one. Because of this, a message can be transmitted to more than one address continuously, or the table data stored in any word can be transmitted continuously. • The Protocol Support Software automatically allows transmission of any communication message with an error check code, such as SUN, LRC, or CRC, and data for the length of the communication message. At the destination address of the communication message, the Protocol Support Software allows the checking of the communication message according to the error check code and the data for the length of the communication message so the destination address can receive the communication message correctly. • The process can be defined with an END, GOTO, NEXT, or ABORT that is executed right after each step is executed with or without any error. • A maximum of 15 types of expected reception messages can be set with a reception matrix. Each of the expected reception messages can include data that determines the next process to be executed and the error processing command to be executed if there is a message reception error. Note: Refer to the Protocol Support Software Operation Manual (W305) for details. 94  PROGRAMMING SOFTWARE PROTOCOL SUPPORT SOFTWARE System Settings C200HW-ZW3AT1-E Protocol Support Software Set communication conditions according to the application when using the protocol macro for communication. The standard communication conditions are shown here. ITEM SPECIFICATIONS No. of start bits 1 Data length 7 bits Parity Even No. of stop bits 2 Baud rate 9,600 bps C200HX/HG/HE Standard measuring devices, components, and personal computers RS-232C Asynchronous (start-stop synchronization) communication Modem Visual Inspection System Intelligent Signal Processor ID Controller Temperature Controller Bar code reader Laser micrometer System Configuration Using the protocol macro, you can customize communications sequences for a variety of communications devices that use RS-232C, RS-422, or RS-485 lines. Refer to the following system configuration. Configuration of Communication Sequences -- A maximum of 1,000 communications sequences (i.e., communications sequences 0 to 999) can be registered, each consisting of 16 steps max. Starts processing Protocol macro executed PMCR Port B: 28912 Port A: 28908 Step 0 Port Port B specification 2 Sequence no. for port specification + communications sequence no. No. of first word of output data to Communications sequence 000 Step 15 to Step 0 Communications sequence 999 to No. of first word of input data Step 15 Port A Port specification 1 Step 0 Communications sequence 000 to Step 15 to Communications sequence 999 Step 0 to Step 15 95  PROGRAMMING SOFTWARE PROTOCOL SUPPORT SOFTWARE E5AJ Temperature Controller Connection Example Connections C200HX AL001 RS-422 RS-422 RS-422 RS-422 #0 RS-422 RS-422 #1 #2 #3 RS-422 Port A E5AJ-A2H02 E5AJ-A2H02 E5AJ-A2H02 E5AJ-A2H02 Program Example In this example, the E5AJ is set to a target value. Start condition PMCR execute flag Port A specification with communications sequence 205 @PMCR Setting Units and Values #1205 DM0506 DM1000 DM word Set data Meaning DM 0506 DM 0507 DM 0508 0003 0003 0085 No. of words for transmission data Unit no. Target value (85°C) End Code: This communications sequence is set to any word because there is no reception data for the communications sequence. 96  PROGRAMMING PERIPHERALS AND CABLES OVERVIEW These are the devices available for programming and diagnostics. C200H-LK201-V1 C200HX/HG/HE Mounted directly Host Link Module RS-232C port CONNECTING CABLES C200H-CN222/422 (2 m/4 m) Programming Console Connecting Cable C200HS-CN220-EU C200HS-CN229-EU C500-CN221-EU C500-CN222-EU Connecting Cable Peripheral port CQM1-CIF02 Connecting Cable C500-ZL3AT1-EV1.2 PERIPHERAL DEVICE SYSWINHL-V3.1 SUPPORT SOFTWARE IBM PC/AT or Compatible Programming Console for C200H C200H-PRO27-E SYSMAC Support Software SYSWIN Programming Console CQM1-PRO01-E 97  PROGRAMMING PERIPHERALS AND CABLES OVERVIEW Programming Consoles C200H-PRO27-E Programming Console CQM1-PRO01-E Programming Console There are two programming consoles that can be used with the C200HX/C200HG/C200HE: The C200H-PRO27-E and the CQM1-PRO01-E. The programming console is a complete online and off-line programming and monitoring hand-held console. In addition to programming and monitoring with the programming console, users can verify programs, compare and create I/O tables, monitor multiple I/O, force set/reset bits, and choose from run, monitor, debug or program modes. The C200H-PRO27-E Programming Console connects to the C200HX/C200HG/C200HE CPU peripheral port with C200H-CN222 or C200H-CN422 Connecting Cable (cable purchased separately). The CQM1-PRO01-E Programming Console comes with a 2 m connecting cable which connects to the C200HX, C200HG, or C200HE CPU peripheral port. C200H-CN222/422 Programming Console Connecting Cable (2 m/4 m) Connecting Cables CQM1-CIF02 Connecting Cable 98 C200HS-CN220-EU C200HS-CN229-EU C500-CN221-EU C500-CN222-EU Connecting Cable There are several cables which allow you to connect a PC to the C200HX/HG/HE for programming and monitoring, using SYSWIN or SSS. The C200HS-CN220-EU (9-pin RS-232C) and the C200HS-CN229-EU (25-pin RS-232C) cables connect a PC to a built-in RS-232C port of the C200HX/HG/HE CPU. The C500-CN221-EU (9-pin RS-232C) and C500-CN222-EU (25-pin RS-232C) cables connect a PC to a rack-mounted C200H-LK201-V1.  PROGRAMMING INSTRUCTIONS GENERAL INFORMATION AND BASIC INSTRUCTIONS General Information • An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. • An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. • An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   Basic Instructions NAME MNEMONIC • • • SYMBOL FUNCTION LOAD LD B Defines the status of bit B as the execution condition for subsequent operations in the instruction line. LOAD NOT LD NOT B Defines the status of the inverse of bit B as the execution condition for subsequent operations in the instruction line. AND AND B Logically ANDs the status of the designated bit with the current execution condition. AND NOT AND NOT B Logically ANDs the inverse of the designated bit with the current execution condition. OR OR B Logically ORs the status of the designated bit with the current execution condition. OR NOT OR NOT B Logically ORs the inverse of the designated bit with the execution condition. AND LOAD AND LD Logically ANDs the resultant execution conditions of the preceding logic blocks. OR LOAD OR LD Logically ORs the resultant execution conditions of the preceding logic blocks. OUTPUT OUT B Turns ON B for an ON execution condition; turns OFF B for an OFF execution condition. OUTPUT NOT OUT NOT B Turns OFF B for an ON execution condition; turns ON B for an OFF execution condition. SET SET SET B Turns the operand bit OFF when the execution condition is ON, and does not affect the status of the operand bit when the execution condition is OFF. RESET RSET RST B Turns the operand bit ON when the execution condition is ON, and does not affect the status of the operand bit when the execution condition is OFF. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   99  PROGRAMMING INSTRUCTIONS BASIC INSTRUCTIONS (CONTINUED) SYMBOL NAME MNEMONIC CP COUNTER CNT FUNCTION CNT N R SV REVERSIBLE COUNTER CNTR (12) II DI R TIMER TIM CNTR(12) N SV TIM N A decrementing counter. SV: 0 to 9999; CP: count pulse; R: reset input. The TC bit is entered as a constant. Increases or decreases the PV by one whenever the increment input (II) or decrement input (DI) signals, respectively, go from OFF to ON. SV: 0 to 9999; R: reset input. ON-delay (decrementing) timer operation. Set value: 000.0 to 999.9 s. SV TOTALIZING TIMER TTIM(87) TTIM(87) N SV RB  HIGH- SPEED TIMER TIMH(15) TIMH(15) N Creates a totalizing timer. A high-speed, ON-delay (decrementing) timer. SV: 00.02 to 99.99 s. The TC bit is entered as a constant. SV END END(01) INTERLOCK IL(02) INTERLOCK CLEAR ILC(03) END(01) Required at the end of each program. Instructions located after END(01) will not be executed. IL(02) Creates interlocks used to control execution of program sections. The entire section is reset when execution is completed. ILC(03) JUMP JMP(04) JUMP END JME(05) JMP(04) N JME(05) N S KEEP KEEP(11) JUMP transfer program execution to the JUMP END with the same number. Defines a bit (B) as a latch, controlled by the set (S) and reset (R) inputs. KEEP(11) B R • • • 100 NO OPERATION NOP(00) None Nothing is executed and program operation moves to the next instruction. DIFFERENTIATE UP DIFU(13) DIFU(13) B DIFU(13) turns ON the designated bit (B) for one cycle on reception of the leading (rising) edge of the input signal. DIFFERENTIATE DOWN DIFD(14) DIFD(14) B DIFD(14) turns ON the bit for one cycle on reception of the trailing (falling) edge. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS DATA CONVERSION INSTRUCTIONS NAME MNEMONIC SYMBOL BCD-TO- BINARY (@)BIN(23) BIN(23) S R FUNCTION Converts 4-digit, BCD data in source word (S) into 16-bit binary data, and outputs converted data to result word (R). S (BCD) DOUBLE BCD-TO-DOUBLE BINARY (@)BINL(58) BINL(58) S R R (BIN) x100 x160 x101 x161 x102 x162 x103 x163 Converts the BCD value of the two source words (S: starting word) into binary and outputs the converted data to the two result words (R: starting word). R S S+1 BINARY-TO- BCD (@)BCD(24) BCD(24) S R R+1 Converts binary data in source word (S) into BCD, and outputs converted data to result word (R). S (BIN) DOUBLE BINARY-TO-DOUBLE BCD (@)BCDL(59) BCDL(59) S R R (BCD) x160 x100 x161 x101 x162 x102 x163 x103 Converts the binary value of the two source words (S: starting word) into eight digits of BCD data, and outputs the converted data to the two result words. R S S+1 BIT COUNTER (@)BCNT(67) BCNT(67) N SB R  • • • R+1 Counts the number of ON bits in one or more words. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   101  PROGRAMMING INSTRUCTIONS DATA CONVERSION INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL 4-TO-16 DECODER (@)MLPX(76) MLPX(76) S Di R FUNCTION Converts up to four hexadecimal digits in the source word (S), into decimal values from 0 to 15, and turns ON the corresponding bit(s) in the result word(s) (R). S 0 to F R 15 16-TO-4 ENCODER (@)DMPX(77) DMPX(77) S R Di 00 Determines the position of the leftmost ON bit in the source word(s) (starting word: S) and turns ON the corresponding bit(s) in the specified digit of the result word (R). 15 00 S R 7-SEGMENT DECODER (@)SDEC(78) SDEC(78) S Di D 0 to F Converts hexadecimal values from the source word (S) into 7-segment display data. Results are placed in consecutive half-words, starting at the first destination word (D) S 0 to F D ASCII CONVERT (@)ASC(86) ASC(86) S Di D Converts hexadecimal digits from the source word (S) into 8-bit ASCII values, starting at leftmost or rightmost half of the starting destination word (D). S 0 to F 8-bit D data 15 2’S COMPLEMENT (@)NEG NEG(--) S R ---  DOUBLE 2’S COMPLEMENT (@)NEGL  • • • 102 NEGL(--) S R --- 08 07 00 Converts the four-digit hexadecimal content of the source word to its 2’s complement and outputs the result to R. Converts the eight-digit hexadecimal content of the source words to its 2’s complement and outputs the result to R and R+1. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS DATA CONVERSION INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL ASCII-TO-HEXADECIMAL (@)HEX  FUNCTION Converts ASCII data to hexadecimal data. HEX(--) S Di D Di: 0011 S 1st D byte 0 2nd byte 1 2 3 LINE (@)LINE(63) LINE(63) S C D LINE-TO- COLUMN (@)COLM(64) COLM(64) S D C  HOURS-TO- SECONDS (@)SEC(65) SEC(65) SECONDS- TO-HOURS (@)HMS(66) HMS(66) ARITHMETIC PROCESS (@)APR(69) APR(69) C S D  S R ------  S R ------  • • • Fetches data from the same numbered bit (C) in 16 consecutive words (where S is the address of the first source word), and creates a 4-digit word with them. Bit C D S 0 0 00 S+1 1 1 01 S+15 0 0 15 Places bit data from the source word (S), consecutively into the same numbered bits of the 16 consecutive destination words. S Bit C 00 1 1 D 01 1 1 D+1 15 0 0 D+15 Converts a time given in hours/minutes/seconds (S and S+1) to an equivalent time in seconds only (R and R+1). Converts a time given in seconds (S and S+1) to an equivalent time in hours/minutes/seconds (R and R+1). Calculates the cosine, or sine of the given degree value, or determines the y-coordinate of the given x value in a previously established line graph. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   103  PROGRAMMING INSTRUCTIONS SPECIAL PROCESSING INSTRUCTIONS SYMBOL NAME MNEMONIC FUNCTION TRACE MEMORY SAMPLING TRSM(45) TRSM(45) Initiates data tracing. DISPLAY MESSAGE (@)MSG(46) MSG(46) Displays eight words of ASCII code, starting from FM, on the Programming Console or GPC. FM FM FM+ 7 A B C D D P ABCD........DP LONG MESSAGE (@)LMSG(47) LMSG(47)  S D ------ SCALING (@)SCL SCL(--) S P1 R  DATA SEARCH (@)SRCH SRCH(--) N R1 C  Finds the maximum value in specified data area and outputs that value to another word. FIND MINIMUM (@)MIN MIN(--) C R1 D Finds the minimum value in specified data area and outputs that value to another word. SUM (@)SUM SUM(--) C R1 D Computes the sum of the contents of the words in the specified range of memory.  104 Searches the specified range of memory for the specified data. Outputs the word address(es) of words in the range that contain the data. MAX(--) C R1 D  • • Performs a scaling conversion on the calculated value. FIND MAXIMUM (@)MAX  • Outputs a 32-character message to either a Programming Console, or a device connected via the RS-232C interface. The output message must be in ASCII beginning at address S. R1 R1+1 R1+2 R1+3 MSB 1 3 5 7 LSB 2 4 6 8 An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS SPECIAL PROCESSING INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL FRAME CHECKSUM (@)FCS FCS(--) C R1 D  AVERAGE VALUE (@)AVG AVG(--) S N D  FAILURE POINT DETECTION FPD  PID CONTROL PID • • FPD(--) C T D PID(--) S C D  • FUNCTION Checks for errors in data transmitted by a Host Link command. R1 R1+1 R1+2 R1+3 MSB 1 3 5 7 LSB 2 4 6 8 Adds the specified number of hexadecimal words and computes the mean value. Rounds off to 4 digits past the decimal point. Finds errors within an instruction block. PID control is performed according to the operand and PID parameters that are preset. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   105  PROGRAMMING INSTRUCTIONS DATA SHIFTING INSTRUCTIONS SYMBOL NAME MNEMONIC FUNCTION I SHIFT REGISTER SFT(10) P R Creates a bit shift register for data from the starting word (St) through to the ending word (E). SFT(10) St E 15 00 15 00 E REVERSIBLE SHIFT REGISTER (@)SFTR(84) SFTR(84) C St E St IN Shifts bits in the specified words either left or right. Starting (St) and ending words (E) must be specified. 15 00 15 E 00 S t IN CY 15 00 15 E IN 00 St CY ASYNCHRONOUS SHIFT REGISTER (@)ASFT(17)  ASFT(17) C St E WORD SHIFT (@)WSFT(16) WSFT(16) St Creates and controls a reversible non-synchronous word shift register between St and E. Exchanges the content of a word containing zero with the content of either the preceding or following word, depending on the shift direction. The data in the words from the starting word (St) through to the ending word (E), is shifted left in word units, writing all zeros into the starting word. E ARITHMETIC SHIFT LEFT (@)ASL(25) ASL(25) Wd Each bit within a single word of data (Wd) is shifted one bit to the left, with zero written to bit 00 and bit 15 moving to CY. 15 CY ARITHMETIC SHIFT RIGHT (@)ASR(26) ASR(26) Wd 15 • • 106 0 Each bit within a single word of data (Wd) is shifted one bit to the right, with zero written to bit 15 and bit 00 moving to CY. 0 • 00 Wd 00 Wd CY An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS DATA SHIFTING INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL ROTATE LEFT (@)ROL(27) ROL(27) Wd FUNCTION Each bit within a single word of data (Wd) is moved one bit to the left, with bit 15 moving to carry (CY), and CY moving to bit 00. 15 00 CY Wd ROTATE RIGHT (@)ROR(28) ROR(28) Wd Each bit within a single word of data (Wd) is moved one bit to the right, with bit 00 moving to carry (CY), and CY moving to bit 15. 15 CY ONE DIGIT SHIFT LEFT (@)SLD(74) SLD(74) St E 00 Wd Shifts all data, between the starting word (St) and ending word (E), one digit (four bits) to the left, writing zero into the rightmost digit of the starting word. St 0 St + 1 E ONE DIGIT SHIFT RIGHT (@)SRD(75) SRD(75) E St Shifts all data, between starting word (St) and ending word (E), one digit (four bits) to the right, writing zero into the leftmost digit of the ending word. E E -- 1 St 0 • • • An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   107  PROGRAMMING INSTRUCTIONS BCD ARITHMETIC INSTRUCTIONS SYMBOL NAME MNEMONIC BCD ADD (@)ADD(30) FUNCTION ADD(30) Au Ad R Adds two 4-digit BCD values (Au and Ad) and content of CY, and outputs the result to the specified result word (R). CY Au + Ad + DOUBLE BCD ADD (@)ADDL(54) ADDL(54) Au Ad R R Adds two 8-digit values (2 words each) and the content of CY, and outputs the result. + Au+ 1 Au Ad+ 1 Ad + CY CY BCD SUBTRACT (@)SUB(31) SUB(31) Mi Su R R+ 1 SUBL(55) Mi Su R R Subtracts both the 4-digit BCD subtrahend (Su) and content of CY, from the 4-digit BCD minuend (Mi) and outputs the result to the specified result word (R). Mi -- Su -- DOUBLE BCD SUBTRACT (@)SUBL(55) CY R -- Mi Su Su + 1 -- CY CY MUL(32) Md Mr CY Subtracts both the 8-digit BCD subtrahend and the content of CY from an 8-digit BCD minuend, and outputs the result. Mi + 1 BCD MULTIPLY (@)MUL(32) CY R+ 1 R Multiplies the 4-digit BCD multiplicand (Md) and 4-digit BCD multiplier (Mr), and outputs the result to the specified result words (R and R + 1). R R+1 Md x Mr DOUBLE BCD MULTIPLY (@)MULL(56) MULL(56) Md Mr R Multiplies the 8-digit BCD multiplicand and 8-digit BCD multiplier, and outputs the result. X R+3 • • • 108 R Md+ 1 Md Mr+ 1 Md R+2 R+1 R An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS BCD ARITHMETIC INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL BCD DIVIDE (@)DIV(33) FUNCTION DIV(33) Dd Dr R Divides the 4-digit BCD dividend (Dd) by the 4-digit BCD divisor (Dr), and outputs the result to the specified result words. R receives the quotient; R + 1 receives the remainder. Dd ÷ Dr DOUBLE BCD DIVIDE (@)DIVL(57) DIVL(57) Dd Dr R R+1 R Divides the 8-digit BCD dividend by an 8-digit BCD divisor, and outputs the result. Dd + 1 Dd Dr + 1 Dr Quotient R+1 R Remainder R+3 R+2 ÷ SET CARRY (@)STC(40) STC(40) Sets the Carry Flag (i.e., turns CY ON). CLEAR CARRY (@)CLC(41) CLC(41) Clears the Carry Flag (i.e, turns CY OFF). INCREMENT (@)INC(38) INC(38) Wd Increments the value of a 4-digit BCD word (Wd) by one, without affecting carry (CY). DECREMENT (@)DEC(39) DEC(39) Wd Decrements the value of a 4-digit BCD word by 1, without affecting carry (CY). SQUARE ROOT (@)ROOT(72) ROOT(72) Computes the square root of an 8-digit BCD value (Sq and Sq + 1) and outputs the truncated 4-digit, integer result to the specified result word (R). Sq R Sq+1 Sq R FLOATING POINT DIVIDE (@)FDIV(79) FDIV(79) Dd Dr R Divides one floating point value by another and outputs a floating point result. ÷ • • • Dd+ 1 Dd Dr+ 1 Dr R+1 R An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   109  PROGRAMMING INSTRUCTIONS ADVANCED I/O INSTRUCTIONS SYMBOL NAME MNEMONIC TEN KEY INPUT TKY TKY(--) IW D1 D2  HKY(--) IW OW D This instruction inputs 8 digits in hexadecimal from a hexadecimal keyboard. DIGITAL SWITCH INPUT DSW DSW(--) IW OW R Inputs 4- or 8-digit BCD data from a digital switch. 7-SEGMENT DISPLAY OUTPUT 7SEG 7SEG(--) S O C Converts 4- or 8-digit BCD data to 7-segment display format and then outputs the converted data. MATRIX INPUT MTR MTR(--) IW OW D    • • 110 Inputs 8 digits of BCD data from a 10-key keypad. HEXADECIMAL KEY INPUT HKY  • FUNCTION Inputs data from an 8 input point × 8 output point matrix and records that data in D to D+3. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS SUBROUTINE INSTRUCTIONS SYMBOL NAME MNEMONIC SBS(91) N Calls subroutine N. Moves program operation to the specified subroutine. SUBROUTINE DEFINE SBN(92) SBN(92) N Marks the start of subroutine N. SUBROUTINE RETURN RET(93) MACRO (@)MCRO(99) INTERRUPT CONTROL (@)INT(89)  • • • FUNCTION SUBROUTINE ENTRY (@)SBS(91) RET(93) Marks the end of a subroutine and returns control to the main program. MCRO(99) N I1 O1 Calls and executes a subroutine replacing I/O words. INT(89) CC N D Controls scheduled interrupts and interrupts from Interrupt Input Units. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   111  PROGRAMMING INSTRUCTIONS DATA COMPARISON INSTRUCTIONS SYMBOL NAME MNEMONIC COMPARE (@)CMP(20) SIGNED BINARY COMPARE (@)CPS  DOUBLE COMPARE CMPL(60) DOUBLE SIGNED BINARY COMPARE (@)CPSL  BLOCK COMPARE (@)BCMP(68) FUNCTION CMP(20) Cp1 Cp2 Compares the data in two 4-digit hexadecimal words (Cp1 and Cp2) and outputs result to the GR, EQ, or LE Flags. CPS(--) Cp1 Cp2 Compares two 16-bit (4-digit) signed binary values and outputs the result to the GR, EQ, and LE flags. CMPL(60) S1 S2 Compares the 8-digit hexadecimal values in words S1+1 and S1 with the values in S2+1 and S2, and indicates the result using the Greater Than, Less Than, and Equal Flags. CPSL(--) Cp1 Cp2 Compares two 32-bit (8-digit) signed binary values and outputs the result to the GR, EQ, and LE flags. BCMP(68) S CB Compares a 1-word binary value (S) with the 16 ranges given in the comparison table (CB is the starting word of the comparison block). If the value falls within any of the ranges, the corresponding bits in the result word (R) will be set. R Lower limit S Upper limit Result CB CB+1 1 CB+2 CB+3 0 CB+4 CB+5 1 CB+30 CB+31 0 Lower limit ≤ S ≤ Upper limit 1 TABLE COMPARE (@)TCMP(85) TCMP(85) CD TB R Compares a 4-digit hexadecimal value (CD) with values in table consisting of 16 words. If the value of CD falls within any of the comparison ranges, corresponding bits in result word (R) are set. R CD Tb 0 Tb+1 1 0 Tb+13 1: same 0: different • • • 112 1 Tb+14 0 Tb+15 1 An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS DATA COMPARISON INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL MULTI-WORD COMPARE (@)MCMP(19)  FUNCTION MCMP(19) S1 S2 D AREA RANGE COMPARE ZCP(88)  DOUBLE AREA RANGE COMPARE ZCPL ZCPL(--) CD LL UL  • • • ZCP(--) CD LL UL Compares the data within a block of 16 words of 4-digit hexadecimal data (S1 to S1+15) with that in another block of 16 words (S2 to S2+15) on a word-by-word basis. If the words are not the same, the bit corresponding to different words turns ON in the result word, D. Compares a word to a range defined by lower and upper limits and outputs the result to the GR, EQ, and LE flags. Compares an 8-digit value to a range defined by lower and upper limits and outputs the result to the GR, EQ, and LE flags. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   113  PROGRAMMING INSTRUCTIONS DATA TRANSFER INSTRUCTIONS SYMBOL NAME MNEMONIC FUNCTION MOVE (@)MOV(21) MOV(21) S D Transfers data from source word, (S) to destination word (D). MOVE NOT (@)MVN(22) MVN(22) Transfers the inverse of the data in the source word (S) to destination word (D). S D BLOCK TRANSFER (@)XFER(70) XFER(70) N S D Moves the content of consecutive source words (S gives the address of the starting source word) to consecutive destination words (D is the starting destination word). S BLOCK SET (@)BSET(71) BSET(71) S St E D S+1 D+1 S+N--1 D+N--1 Copies the content of one word or constant (S) to several consecutive words (from the starting word, St, through to the ending word, E). St S E MOVE BIT (@)MOVB(82) MOVB(82) S Bi D Transfers the designated bit of the source word or constant (S) to the designated bit of the destination word (D). S D TRANSFER BITS @XFRB(62)  MOVE DIGIT (@)MOVD(83) XFRB(--) C S D Copies the status of up to 255 specified source bits to the specified destination bits. MOVD(83) S Di D Moves hexadecimal content of up to four specified 4-bit source digit(s) from the source word to the specified destination digit(s). 15 00 S D • • • 114 An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS DATA TRANSFER INSTRUCTIONS (CONTINUED) SYMBOL NAME MNEMONIC FUNCTION NETWORK SEND (@)SEND(90) SEND(90) S D C Transfers data from n source words (S is the starting word) to the destination words (D is the first address) in node N of the specified network (in a SYSMAC LINK or NET Link System). NETWORK RECEIVE (@)RECV(98) RECV(98) S D C Transfers data from the source words (S is the first word) from node N of the specified network (in a SYSMAC LINK or NET Link System) to the destination words starting at D. DIST(80) S DBs Of Moves one word of source data (S) to the destination given by the destination base word (DBs) plus offset (Of). SINGLE WORD DISTRIBUTE (@)DIST(80) S Base (DBs) + Offset (OF) (S) DATA COLLECT (@)COLL(81) COLL(81) SBs Of D XDMR(--) N S D The contents of the designated number of words of the fixed expansion DM data are read and output to the destination word on the PLC side. Base (DBs) + Offset (OF) (SBs+Of) EXPANSION DM READ (@)XDMR  RECEIVE (@)RXD RXD(--) D C N  • • • (DBs + Of) Extracts data from the source word and writes it to the destination word (D). (D) Receives data via a communications port. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   115  PROGRAMMING INSTRUCTIONS DATA TRANSFER INSTRUCTIONS (CONTINUED) SYMBOL NAME MNEMONIC TRANSMIT (@)TXD TXD(--) S C N  EM CONSTANT BLOCK TRANSFER (@)XFR2 XFR2 W S N  EM CONSTANT INTERBANK BLOCK TRANSFER (@)BXF2  SETUP CHANGE (@)STUP  EXPANSION DM BANK CHANGE (@)EMBC EMBC N INDIRECT EXPANSION DM SETTING (@)IEMS IEMS C  • • 116 BXF2 C S D STUP N S  • FUNCTION Sends data via a communications port. Sends data of more than one word existing in series from the designated word to the words following the designated word. When a constant is designated where the data is sent to or sent from, the EM area is designated. Sends data of more than one word existing in series from the designated word to the words following the designated word. If the designated word is in an EM area, the bank number can be specified. Sends the designated word content (for 5 words) to the system setting area of designated RS-232 port. Changes the current bank of the Expansion DM. Switches the indirect execution area between DM and EM. Current bank can be switched when changing to EM. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS LOGIC INSTRUCTIONS SYMBOL NAME MNEMONIC FUNCTION LOGICAL AND (@)ANDW(34) ANDW(34) I1 I2 R Logically ANDs two 16-bit input words (I1 and I2) and sets the bits in the result word (R) if the corresponding bits in the input words are both ON. LOGICAL OR (@)ORW(35) ORW(35) I1 Logically ORs two 16-bit input words (I1 and I2) and sets the bits in the result word (R) when one or both of the corresponding bits in the input words is/are ON. I2 R EXCLUSIVE OR (@)XORW(36) XORW(36) I1 I2 R Exclusively ORs two 16-bit input words (I1 and I2) and sets the bits in the result word (R) when the corresponding bits in input words differ in status. EXCLUSIVE NOR (@)XNRW(37) XNRW(37) I1 Exclusively NORs two 16-bit input words (I1 and I2) and sets the bits in the result word (R) when the corresponding bits in both input words have the same status. I2 R COMPLEMENT (@)COM(29) COM(29) Wd Inverts bit status of one word (Wd) of data, changing 0s to 1s, and vice versa. Wd • • •  An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   117  PROGRAMMING INSTRUCTIONS SYSTEM PROCESSING INSTRUCTIONS NAME MNEMONIC SYMBOL FAL(06) N Assigns a failure alarm code to the given execution condition. This code is generated as an error code whenever the instruction is executed. SEVERE FAILURE ALARM FALS(07) FALS(07) N A fatal version of FAL(06). When a FALS(07) instruction is executed the CPU is stopped and the number is generated as an error code. CYCLE TIME (@)SCAN(18) SCAN(18)  Mi TERM(48)  WDT(94) T Sets the maximum and minimum limits for the watchdog timer (normally 0 to 130 ms). New limits: Maximum time = 130 + (100 x T) Minimum time = 130 + (100 x (T--1)) I/O REFRESH (@)IORF(97) IORF(97) St E Can refresh I/O words allocated to CPU or Expansion I/O Racks and Special I/O Modules. GROUP-2 HIGH-DENSITY I/O REFRESH (@)MPRF(61) MPRF(61) St E Refreshes I/O words allocated to Group-2 High-density I/O Modules.  INTELLIGENT IO READ (@)IORD IORD C S D  INTELLIGENT IO WRITE (@)IORW IOWR C S D  PROTOCOL MACRO (@)PMCR PMCR C S D  CARD MACRO (@)CMCR CMCR C S D  118 Shifts the Programming Console to TERMINAL mode. ---------------- WATCHDOG TIMER REFRESH (@)WDT(94) • • Sets the minimum cycle time, Mi, in tenths of milliseconds. The possible setting range is from 0 to 999.0 ms. ----------- TERMINAL MODE (@)TERM(48) • FUNCTION FAILURE ALARM (@)FAL(06) Reads data of more than one word from an ASCII Module, etc. Writes data of more than one word from a PLC’s CPU to an ASCII Module. By calling the send/receive sequence (protocol data) registered in the Communication Board connected to a PLC’s CPU, data can be sent to or received from another personal computer that has RS-232C. Reads or writes files in the memory card of the PC Card Module. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS STEP LADDER INSTRUCTIONS NAME MNEMONIC • • • SYMBOL FUNCTION STEP DEFINE STEP(08) STEP(08) B When used with a control bit (B), defines the start of a STEP START SNXT(09) SNXT(09) B new step and resets the previous step. When used without B, it defines the end of step execution. Used with a control bit (B) to indicate the end of the step, reset the step, and start the next step which has been defined with the same control bit. An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   119  PROGRAMMING INSTRUCTIONS BINARY ARITHMETIC INSTRUCTIONS NAME MNEMONIC SYMBOL BINARY ADD (@)ADB(50) ADB(50) Au Ad R FUNCTION Adds the 4-digit augend (Au), 4-digit addend (Ad), and content of CY and outputs the result to the specified result word (R). Au + Ad + CY R CY DOUBLE BINARY ADD (@)ADBL ADBL(--) Au Ad R  Adds two 8-digit binary values (normal or signed data) and contents of carry, and outputs the result to R and R+1. CY BINARY SUBTRACT (@)SBB(51) SBB(51) Mi Su R Au + 1 Au Ad + 1 Ad + CY R+1 R Subtracts the 4-digit hexadecimal subtrahend (Su) and content of carry, from the 4-digit hexadecimal minuend (Mi), and outputs the result to the specified result word (R). Mi   Su CY R CY DOUBLE BINARY SUBTRACT (@)SBBL  SBBL(--) Mi Su R Subtracts an 8-digit binary value (normal or signed data) and contents of carry from another and outputs the result to R and R+1. Mi + 1 Mi Su + 1 Su -CY BINARY MULTIPLY (@)MLB(52) MLB(52) Md Mr R CY R+1 R Multiplies the 4-digit hexadecimal multiplicand (Md) and 4-digit multiplier (Mr), and outputs the 8-digit hexadecimal result to the specified result words (R and R+1). Md X R+1 • • • 120 Mr R An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.    PROGRAMMING INSTRUCTIONS BINARY ARITHMETIC INSTRUCTIONS (CONTINUED) NAME MNEMONIC SYMBOL SIGNED BINARY MULTIPLY (@)MBS  FUNCTION MBS(--) Md Mr R Multiplies the signed binary content of two words and outputs the 8-digit signed binary result to R+1 and R. MBSL(--) Md Mr R Multiplies two 32-bit (8-digit) signed binary values and outputs the 16-digit signed binary result to R+3 through R. Md Mr X R +1 DOUBLE SIGNED BINARY MULTIPLY (@)MBSL  R X R+3 BINARY DIVIDE (@)DVB(53) DVB(53) Dd Dr R R+2 Md + 1 Md Mr + 1 Mr R+1 R Divides the 4-digit hexadecimal dividend (Dd) by the 4-digit divisor (Dr), and outputs result to the designated result words ( R and R + 1). Dd ÷ Dr Quotient Remainder SIGNED BINARY DIVIDE (@)DBS  DBS(--) Dd Dr R R R+ 1 Divides one 16-bit signed binary value by another and outputs the 32-bit signed binary result to R+1 and R. Quotient R Dr DOUBLE SIGNED BINARY DIVIDE (@)DBSL  • • • DBSL(--) Dd Dr R Remainder R+1 Dd Divides one 32-bit signed binary value by another and outputs the 64-bit signed binary result to R+3 to R. Remainder R+3 Dr+1 Dr R+2 Quotient R+1 Dd+1 R Dd An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction executing condition is turned ON. An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used. An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.   121  122 STANDARD PARTS STANDARD PARTS 123 123  CPU RACK CPU Rack ITEM DESCRIPTION C Us ((All models CPUs ode s are a e provided o ded with clock l k function f ti and d slots l t for f communications except CPU11-E.) CPU11-E ) UM DM I/O points RS-232C 3.2K words 4K words 640 No C200HE-CPU11-E 7.2K words 6K words 880 No C200HE-CPU32-E 8K words Yes C200HE-CPU42-E 12K words No C200HG-CPU33-E Yes C200HG-CPU43-E No C200HG-CPU53-E Yes C200HG-CPU63-E No C200HX-CPU34-E Yes C200HX-CPU44-E No C200HX-CPU54-E Yes C200HX-CPU64-E 15.2K words PART NUMBER 1,184 31.2K words 24K words 880 1,184 Power Supply Modules CPU I/O Backplanes Communication Boards STANDARDS U, C, N, CE 100 to 120/200 to 240 VAC C200HW-PA204 100 to 120/200 to 240 VAC (with 24-VDC output terminals) C200HW-PA204S 24 VDC C200HW-PD024 3 slots C200HW-BC031 5 slots C200HW-BC051 8 slots C200HW-BC081 10 slots C200HW-BC101 Communications port for SYSMAC LINK and SYSMAC NET Link Modules C200HW-COM01 RS-232C port C200HW-COM02 RS-422/485 port C200HW-COM03 Communications port for the SYSMAC LINK Module and SYSMAC C200HW-COM04-E NET Link Module and a protocol macro function Memory y Cassettes Two RS-232C ports and a protocol macro function C200HW-COM05-E RS-422/485 port, an RS-232C port, and a protocol macro function C200HW-COM06-E EEPROM 4K words C200HW-ME04K 8K words C200HW-ME08K 16K words C200HW-ME16K N 32K words C200HW-ME32K N, CE 16K words/32K words C200HS-MP16K L, CE Equivalent to 27256, 150 ns, 12.5 V ROM-JD-B CE Equivalent to 27512, 150 ns, 12.5 V ROM-KD-B EPROM 124 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. N, CE  EXPANSION Expansion Rack ITEM DESCRIPTION PART NUMBER STANDARDS Power Supply Modules 100 to 120/200 to 240 VAC C200HW-PA204 U, C, N, CE 100 to 120/200 to 240 VAC (with 24-VDC output terminals) C200HW-PA204S 24 VDC C200HW-PD024 3 slots C200HW-BI031 5 slots C200HW-BI051 8 slots C200HW-BI081 10 slots C200HW-BI0101 Expansion I/O Backplanes I/O Connecting Cables /O Co ec g Cab es 30 cm 70 cm The e total o a length e g of o the e I/O /O Connecting Co ec g Cables Cab es used d in i a network t k mustt b be 12 m maximum. i --- C200H-CN311 C200H-CN711 200 cm C200H-CN221 500 cm C200H-CN521 1,000 cm C200H-CN131 Slave Rack Slave Racks Remote I/O Slave Modules 100 to 120/200 to 240 VAC (switchable) APF/ PCF C200H-RT001-P U, C, N, L C200H-RT002-P N, L C200H-RT201 U, C, N, L C200H-RT201-C CE 24 VDC C200H-RT202 N, L, CE 3 slots C200H-BC031-V2 U, C, N, L, CE 5 slots C200H-BC081-V2 8 slots C200H-BC051-V2 10 slots C200H-BC101-V2 24 VDC 100 to 120/200 to 240 VAC (switchable) Backplanes I/O Blocks I/O /O T Terminals i l Link Adapter Input Wired Specify either 12 or 24 VDC. U, C, N, L G71-IC16 Output G71-OD16 AC input Specify either 100 or 200 VAC. G7TC-IA16 DC input Specify either 12 or 24 VDC. G7TC-ID16 Output Specify either 12 or 24 VDC. G7TC-OC16 O/E converter; 1 connector for RS-485, 1 connector each for APF/ PCF B500-AL007-P U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 125  I/O MODULES ITEM DESCRIPTION Input Modules AC Input Modules 100 to 120 VAC C200H-IA121 U, C, N, L 16 pts 100 to 120 VAC C200H-IA122 U, C, N, L 8 pts 200 to 240 VAC C200H-IA221 U, C, N, L 16 pts 200 to 240 VAC C200H-IA222 8 pts 12 to 24 VDC C200H-ID211 16 pts 24 VDC C200H-ID212 8 pts 12 to 24 VAC/DC C200H-IM211 16 pts 24 VAC/DC C200H-IM212 Interrupt Input Module (see note) 8 pts 12 to 24 VDC C200HS-INT01 U, C Relay Output Modules 8 pts 2 A, 250 VAC/24 VDC (for resistive load) C200H-OC221 U, C, N, L 12 pts 2 A, 250 VAC/24 VDC (for resistive load) C200H-OC222 5 pts 2 A, 250 VAC/24 VDC (for resistive load) Independent commons C200H-OC223 8 pts 2 A, 250 VAC/24 VDC (for resistive load) Independent commons C200H-OC224 16 pts 2 A, 250 VAC/24 VDC (for resistive load) (see note) C200H-OC225 8 pts 1 A, 120 VAC C200H-OA121-E U, C 8 pts 1 A, 200 VAC C200H-OA223 N, L, CE 12 pts 0.3 A, 200 VAC C200H-OA222V CE 8 pts 1 A, 12 to 48 VDC C200H-OD411 U, C, N, L, CE 12 pts 0.3 A, 24 VDC C200H-OD211 16 pts 0.3 A, 24 VDC (see note) C200H-OD212 8 pts 2.1 A, 24 VDC C200H-OD213 8 pts 0.8 A, 24 VDC; source type (PNP); w/load short protection C200H-OD214 8 pts 0.3 A, 5 to 24 VDC; source type (PNP) C200H-OD216 12 pts 0.3 A, 5 to 24 VDC; source type (PNP) C200H-OD217 16 pts 1 A, 24 VDC; source type (PNP); w/load short protection C200H-OD21A CE 4 timers 0.1 to 1 s/1 to 10 s/10 to 60 s/1 min to 10 min (switchable) C200H-TM001 U, C Connector w/lead wire (2 m) for 1 external resistor C4K-CN223 --- 15 or 16 input pts Connects to B7A Link Terminals. Standard transmission delay. C200H-B7AI1 U, C, CE 16 output pts Connects to B7A Link Terminals. Standard transmission delay. C200H-B7AO1 (see note) AC/DC Input Modules Triac Output Modules Transistor Output Modules Analog Timer Module Variable Resistor Connector B7A Interface Modules Note: 126 STANDARDS 8 pts DC Input Modules Output Modules PART NUMBER U, C, N, L, CE U, C, N, L If the Interrupt Input Module is mounted on an Expansion I/O Rack, the interrupt function cannot be used and the Interrupt Input Module will be treated as an ordinary 8-point Input Module. Moreover, Interrupt Input Modules cannot be used on Slave Racks. U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met.  SPECIAL I/O MODULES (INCLUDING GROUP 2 I/O) Group-2 I/O Modules ITEM DESCRIPTION DC Input Modules 32 pts 24 VDC 64 pts Transistor Output Modules B7A Interface Modules (GROUP 2 I/O MODULES) 32 pts 32 output pts STANDARDS C200H-ID216 U, C, N, L, CE C200H-ID217 16 mA at 4.5 V to 100 mA at 26.4 V 64 pts 32 input pts PART NUMBER U, C, N, L C200H-OD218 C200H-OD219 Connects to B7A Link Terminals. Standard or high-speed hi h d transmission t i i delay. d l --- C200H-B7A12 C200H-B7A02 16 input and 16 output points C200H-B7A21 32 input and 32 output points C200H-B7A22 DESCRIPTION PART NUMBER STANDARDS U,, C,, N,, L,, CE Special I/O Modules ITEM High-density g y I/O M Modules d l (see note 1) DC Input Modules Transistor Output Modules DC Input/Transistor Output Modules Analog I/O Modules Analog Input Modules Analog Output Modules Fuzzy Logic Module Fuzzy Support Software Temperature Sensor Module 32 pts 5 VDC (TTL inputs); w/high-speed input C200H-ID501 32 pts 24 VDC; w/high-speed input C200H-ID215 32 pts 0.1 A, 24 VDC (useable as 128-point dynamic output unit) C200H-OD215 32 pts 35 mA, 5 VDC (TTL outputs) (useable as 128-point dynamic output unit) C200H-OD501 16 input and 16 output pts 24-VDC inputs; w/high-speed input; 0.1-A, 24-VDC outputs (useable as 128-point dynamic input unit) C200H-MD215 16 input and 16 output pts 5-VDC TTL inputs; w/high speed input; 35-mA, 5-VDC TTL outputs (useable as 128-point dynamic input unit) C200H-MD501 16 input and 16 output pts 12-VDC TTL inputs; w/high speed input; 12-VDC TTL outputs (useable as 128-point dynamic input unit) C200H-MD115 N, L 4 to 20 mA, 1 to 5/0 to 10 V (switchable); 4 inputs; 12 bits C200H-AD001 U, C, N, L 4 to 20 mA, 1 to 5/0 to 10 V/--10 to 10V (switchable); 8 inputs; 12 bits or BCD C200H-AD002 4 to 20 mA, 1 to 5/0 to 10 V (switchable); 2 outputs C200H-DA001 4 to 20 mA, --10 to 10 V; 4 outputs C200H--DA002 --- Programmed using the Fuzzy Support Software. C200H-FZ001 N Available on either 3.5” or 5.25” floppy disks. C500-SU981-E --- Thermocouple K(CA) or J(IC), switchable; 4 inputs C200H-TS001 U, C K(CA) or L(Fe-CuNi) DIN standards; 4 inputs C200H-TS002 Pt 100 Ω; 4 inputs C200H-TS101 Pt 100 Ω; 4 inputs; DIN and 1989 JIS standards C200H-TS102 Pt resistance thermometer U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 127  SPECIAL I/O (CONTINUED) ITEM DESCRIPTION Temperature Control Modules Thermocouple Pt resistance thermometer Heat/Cool Temperat re Control Mod Temperature Modules les Thermocouple Pt resistance thermometer Cam Positioner Module PART NUMBER STANDARDS Transistor output C200H-TC001 U, C Voltage output C200H-TC002 Current output C200H-TC003 Transistor output C200H-TC101 Voltage output C200H-TC102 Current output C200H-TC103 Transistor output C200H-TV001 Voltage output C200H-TV002 Current output C200H-TV003 Transistor output C200H-TV101 Voltage output C200H-TV102 Current output C200H-TV103 Detects angles of rotation by means of a resolver and provides ON and OFF outputs at specified angles. A maximum of C200H-CP114 48 cam outputs (16 external outputs and 32 internal outputs) maximum are available. Data Setting Console Connecting g Cables PID Control Modules Position Control Modules High-speed Counter Modules ASCII/BASIC Modules 128 Used to set and monitor data in Temperature Control Modules and C200H-DSC01 Cam Positioner Modules. 2m C200H-CN225 4m C200H-CN425 Transistor output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs (selectable) C200H-PID01 Voltage output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs (selectable) C200H-PID02 Current output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs (selectable) C200H-PID03 1 axis Pulse output; directly connects to servomotor driver; compatible with line driver; speeds: 1 to 250,000 pps C200H-NC112 U, C, CE 2 axis Pulse output; speeds: 1 to 250,000 pps, 53 pts per axis C200H-NC211 U, C 1 axis Pulse input; counting speed: 50 kcps; 5 VDC/12 VDC/24 VDC C200H-CT001-V1 U, C, CE 1 axis Pulse input; counting speed: 75 kcps; RS-422 line driver C200H-CT002 2 axis Pulse input; counting speed: 75 kcps; RS-422 line driver C200H-CT021 24K-byte RAM and 24K-byte EEPROM are built-in. C200H-ASC02 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. --U, C CE  SPECIAL I/O (CONTINUED) ITEM DESCRIPTION PART NUMBER STANDARDS RFID Sensor Modules Local application, electromagnetic coupling C200H-IDS01-V1 U, C Remote application; microwave transmissions C200H-IDS21 --- Electromagnetic type V600-H series Microwave type V620-H series SRAM type for V600-H series. V600-D Read/Write Heads Data Carriers Voice Module Connecting Cable Motion Control Module 60 messages max.; message length: 32, 48, or 64 s (switchable) C200H-OV001 RS-232C C200H-CN224 G-language programmable 2-axis analog outputs C200H-MC221 MC Support Software IBM PC/AT or compatible CV500-ZN3AT1-E Connecting cable 3.3 m CQM1-CIF02 Teaching Box --- CVM1-PRS71 Connection cable for Teaching Box 2 m long CV500-CN224 Memory Pack (with key sheet) (see note 2) --- CVM1-MP701 Terminal Block Conversion Unit Simplifies wiring for I/O connectors. XW2B-20J6-6 Connecting cable for Terminal Block Conversion Unit Note: EEPROM type for V600-H series. R V600-DP --- XW2Z-100J-F1 1. When mounting a High-density I/O Module as a Special I/O Module to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-RM201. 2. The CV-series Programming Console can be used as a Teaching Box by replacing the Memory Pack of the Programming Console. U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 129  I/O MODULE ACCESSORIES ITEM DESCRIPTION PART NUMBER I/O /O Terminal e a BLock oc Co Cover e For 10 pin I/O Terminal Blocks For 19 pin I/O Terminal Blocks For 5- and 8- point Modules 24-pin, solder type, straight 24-pin, crimp type 24-pin, for ribbon cable 24-pin, solder type, 90° angle 40-pin, solder type, straight 40-pin, crimp type 40-pin, for ribbon cable 40-pin, solder type, 90° angle RS-232C, 25 pins RS-422, 9 pins RS-232C, 25 pins RS-422, 9 pins C200H-COV02 C200H-COV03 C200H-COV11 C500-CE241 C500-CE242 C500-CE243 C500-CE244 C500-CE401 C500-CE402 C500-CE403 C500-CE404 0020756-4, RS-232 connector 0020757-2, RS-422 connector 0020758-0, RS-232 cover 0020759-9, RS-422 cover Connector Co ec o Connector Cover 130 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met.  COMMUNICATION MODULES ITEM DESCRIPTION PART NUMBER STANDARDS PC Card Module A memory card suitable for Phoenix PCM+3.2 and one of the following Bus Connection Units is required. No PC card is provided with the module. C200HW-PCU01-E --- Ethernet Set A floppy disk containing Ethernet setup utility data is provided. One of the following Bus Connection Units is required. No PC card is provided with the Module. C200HW-PCS01-E Bus Connection Units For 1 Module C200HW-CE011 For 2 Modules C200HW-CE012 SYSMAC LINK Module (coaxial cable) A Bus Connection Unit must be ordered separately. y Data link table: 918 words C200HW-SLK23 Data link table: 2,966 words C200HW-SLK24 Terminator One required for each node at ends of System. C1000H-TER01 Attachment Stirrup Provided with SYSMAC LINK Module. C200H-TL001 F Adapter To connect network C1000H-CE001 F Adapter Cover To connect network SYSMAC LINK Module (fiber-optic cable) U, C, N --- C1000H-COV01 Connect with H-PCF cable. A Bus Connection y Unit must be ordered separately. Data link table: 918 words C200HW-SLK13 Data link table: 2,966 words C200HW-SLK14 U, C, N Power Supply Adapter Required when supplying backup power For 1 or 2 Modules C200H-APS03 U, C Power Cable Connects Power Supply y Adapter and SYSMAC NET Li k Module. Link M d l For 1 Module C200H-CN111 --- For 2 Modules C200H-CN211 SYSMAC LINK Support Board (coaxial cable) To connect IBM PC/AT or compatible as node in SYSMAC LINK system 3G8F5-SLK21-E SYSMAC NET LINK Module A Bus Connection Unit must be ordered separately. C200HS-SNT32 Power o e Su Supply y Ad t Adapter Required equ ed when e su supplying y g backup bac u power o e Power Cable Connects Power Supply Adapter and SYSMAC NET Link Module. Bus Connection Units Host Link Modules DeviceNet Scanner Module For 1 Module C200H-APS01 For 2 Modules C200H-APS02 Included with C200H-APS01 For 1 Module C200H-CN001 Included with C200H-APS02 For 2 Modules C200H-CN002 For 1 Module C200HW-CE001 For 2 Modules C200HW-CE002 APF/PCF C200H-LK101-PV1 N, L RS-422 C200H-LK202-V1 U, C RS-232C C200H-LK201-V1 Connects SYSMAC LINK Module or SYSMAC NET Link Module to CPU. Rack-mounting Number of I/O points: 1,600 max. Number of Slave Modules: 50 max. C200H, C200HS, C200HE, C200HG, C200HX C200HW-DRM21 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 131 N U, C, N  COMMUNICATION MODULES AND SYSMAC NET/SYSMAC LINK ITEM DESCRIPTION PC Link Module Remote I/O Master Modules Remote I/O Slave Modules Note: PART NUMBER STANDARDS Single level: 32 Modules Multilevel: 16 Modules RS-485 C200H-LK401 N, L Up to two per PLC; connectable to up to 5 Slaves per PLC total APF/PCF C200H-RM001-PV1 Wired C200H-RM201 For reference, see Slave Racks on page 125 (also page 84). Only a single PC Card Module can used with the CPU. SYSMAC NET/SYSMAC LINK Hardware 132 ITEM DESCRIPTION PART NUMBER STANDARDS SYSMAC NET Network Support Board For IBM PC/AT or compatible S3200-NSB11-E --- SYSMAC LINK Network Support Board For IBM PC/AT or compatible, coaxial cable connector 3G8F5-SLK21-E U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met.  FIBER-OPTIC COMMUNICATION MODULE CONNECTIONS 3GS3200 Connectors (S3200 is the Part No. prefix.) C200H C1000H, C2000H CVM1, CV500, CV1000, CV2000 SYSMAC NET Network Support Board SYSMAC NET Line Server SYSMAC NET Bridge SYSMAC NET Network Service Unit SYSMAC NET VME Interface SYSMAC NET SYSMAC LINK SYSMAC WAY SYSMAC BUS COCH82 COCH82 COCF2011 — SYSMAC BUS/2 — — COCF2011 — COCF2511 COCH62M COCF2011 COCH62M COCF2511 COCF2011 COCF2011 — COCH62M COCH62M COCH62M — — — — — — — — — — — — COCH62M — — — — COCH82 COCH82 COCF2011 — 3G5A2 Connectors (-P modules only) 3G5A2 is the Part No. prefix. B500 Part No. prefixes are equivalent to 3G5A2 prefixes. C200H C1000H, C2000H CVM1, CV500, CV1000, CV2000 SYSMAC WAY CO001, CO002 CO001, CO002 — SYSMAC BUS CO001, CO002 CO001, CO002 CO001, CO002 All Plastic Fiber-optic (APF) Cable ITEM DESCRIPTION PART NUMBER Fiber-optic Cable Fiber-optic be o c Connectors 20 m (65.6 ft.), without connectors Brown, for cable 0 to 10 m (0 to 32.8 ft.) long (includes 2) Black, for cable 8 to 20 m (0 to 65.6 ft.) long (includes 2) B500-PF212 3G5A2-CO001 3G5A2-CO002 Hard Plastic-Clad Fiber-optic (HPCF) Cable ITEM DESCRIPTION PART NUMBER Fiber-optic be o c C bl Cable 50 m (164 ft.), without connectors 100 m (328 ft.), without connectors 500 m (0.31 mile), without connectors 1 km (0.62 mile), without connectors Zipcord style, orange, 50 m (164 ft.), without connectors SYSMAC BUS or SYSMAC WAY only SYSMAC BUS/2 (all PLCs), SYSMAC LINK (other than C200H) SYSMAC NET (other than C200H) SYSMAC NET, LINK (C200H only) SYSMAC NET In-line male connector SYSMAC NET In-line female connector SYSMAC LINK In-line adapter For HPCF Cable FCS-HCR-LB-501 FCS-HCR-LB-102 FCS-HCR-LB-502 FCS-HCR-LB-103 FCS-HCR-CO-501 S3200-COCH82 S3200-COCF2011 S3200-COCH62M S3200-COCF2511 S3200-COCF62M S3200-COCF62F S3200-COIAT2000 FCS-CAK6230-US Fiber-optic be o c C Connectors t In-line e Fiber-optic be o c C Connectors t Termination Kit Plastic-Clad Fiber-optic (PCF) Cable ITEM DESCRIPTION PART NUMBER Indoor Fiber-optic C bl Cable 10 cm (0.32 ft.), with connectors 1 m (3.2 ft.), with connectors 2 m (6.56 ft.), with connectors 3 m (9.8 ft.), with connectors 5 m (16.4 ft.), with connectors 10 m (32.8 ft.), with connectors 20 m (65.6 ft.), with connectors 30 m (98 ft.), with connectors 50 m (164 ft.), with connectors 100 m (328 ft.), with connectors 200 m (656 ft.), with connectors 400 m (0.25 mile), with connectors 800 m (0.5 mile), with connectors 3G5A2-OF011 3G5A2-OF101 3G5A2-OF201 3G5A2-OF301 3G5A2-OF501 3G5A2-OF111 3G5A2-OF211 3G5A2-OF311 3G5A2-OF511 3G5A2-OF002-100M 3G5A2-OF002-200M 3G5A2-OF002-400M 3G5A2-OF002-800M Indoor/Outdoor doo /Ou doo Fib Fiber-optic ti Cable C bl U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 133  LINK ADAPTERS 134 ITEM DESCRIPTION PART NUMBER STANDARDS Link Adapters 3 RS-422 connectors 3G2A9-AL001 N, L 3 fiber-optic connectors (APF/PCF) 3G2A9-AL002-PE N 3 fiber-optic connectors (PCF) 3G2A9-AL002-E 1 connector for RS-232C; 2 for RS-422 3G2A9-AL003 --- 1 connector each for APF/PCF, RS-422, and RS-232C 3G2A9-AL004-PE N, L 1 connector each for PCF, RS-422, and RS-232C 3G2A9-AL004-E 1 connector each for APF/PCF and APF 3G2A9-AL005-PE 1 connector each for PCF and AGF 3G2A9-AL005-E 1 connector for APF/PCF; 2 for AGF 3G2A9-AL006-PE 1 connector for PCF; 2 for AGF 3G2A9-AL006-E O/E converter; 1 connector for RS-485, 1 connector each for APF/PCF B500-AL007-P N, L Used for on-line removal of SYSMAC NET Link Units from the SYSMAC NET Link System, SYSMAC NET Fiber-optic Link Adapter (3 connectors for APF/PCF) B700-AL001 --- U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. ---  PROGRAMMING DEVICES ITEM DESCRIPTION PART NUMBER STANDARDS Programming Consoles Provided with a 2-m cable for ladder programming C200H-PRO27-E U, C One of the following connection cables is required for ladder programming. CQM1-PRO01-E Programming Console Mounting Bracket Used to attach Hand-held Programming Console to a panel. C200H-ATT01 Programming Console Connecting Cables For C200H-PRO27-E Hand-held Programming Console 2m 4m C200H-CN222 C200HS-CN222 CE C200H-CN422 --- C200HS-CN422 CE --- Data Setting Console Used for data input and process value display for the C200H-TC . C200H-DSC01 Data Setting Console Connecting Cables For C200H-DSC01 2m C200H-CN225 4m C200H-CN425 3.3 m CQM1-CIF02 Connecting Cable  Used to connect an IBM PC/AT or compatible to the C200HX/HG/HE. --- U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 135  OPTIONAL PRODUCTS ITEM DESCRIPTION PART NUMBER STANDARDS I/O Module Cover Cover for 10-pin terminal block C200H-COV11 --- Terminal Block Covers Short protection for 10-pin terminal block (package of 10 covers); 8 pts C200H-COV02 Short protection for 19-pin terminal block (package of 10 covers); 12 pts C200H-COV03 Connector Cover Protective cover for unused I/O Connecting Cable connectors C500-COV02 Space Module Used for vacant slots C200H-SP001 N, L Battery Set For C200H or C200HS RAM Memory Unit only C200H-BAT09 --- Relay 24 VDC G6B-1174P-FD-US CPU Backplane Insulation Plates For 3-slot Backplane C200H-ATT31 For 5-slot Backplane C200H-ATT51 For 8-slot Backplane C200H-ATT81 For 10-slot Backplane C200H-ATTA1 For 3-slot Backplane C200HW-ATT32 For 5-slot Backplane C200HW-ATT52 For 8-slot Backplane C200HW-ATT82 For 10-slot Backplane C200HW-ATTA2 Solder terminal; 40p and a Connector Cover C500-CE401 Solderless terminal; 40p and a Connector Cover (Crimp-type) C500-CE402 Pressure welded terminal; 40p C500-CE403 Solder terminal; 40p and a Connector Cover (Horizontal-type) C500-CE404 Crimp-style terminal; 40p and a Connector Cover (Horizontal-type) C500-CE405 I/O Backplane Insulation Plates External Connectors 136 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. --- N ---  MOUNTING RAIL AND MOUNTING ACCESSORIES ITEM DESCRIPTION PART NUMBER STANDARDS DIN Rail Mounting Bracket 1 set (2 included) C200H-DIN01 --- DIN Rails Length: 50 cm; height: 7.3 cm PFP-50N Length: 1 m; height: 7.3 cm PFP-100N Length: 1 m; height: 16 mm PFP-100N2 End Plate --- PFP-M Spacer --- PFP-S Note: Order DIN Rails, End Plates, and Spacers in units of 10 each. U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met. 137  SOFTWARE SYSMAC Support Software (SSS) ITEM DESCRIPTION PART NUMBER SYSMAC Support Software (for C20, C P, C K, C120, C H, C200H, C200HS, C200HE, C200HG, C200HX, C500, C1000H, C2000H, CQM1, and CVM1) 3.5”, 2HD for IBM PC/AT compatible C500-ZL3AT1-EV1.2 DESCRIPTION PART NUMBER 3.5”, 2HD for IBM PC/AT compatible SYSWINHL-V3.0 ITEM DESCRIPTION PART NUMBER Protocol Support Software 3.5”, 2HD for IBM PC/AT compatible C200HW-ZW3AT1-E    SYSWIN ITEM    SYSWIN (for C20, C P, C K, C120, C H, C200H, C200HS, C200HE, C200HG, C200HX, C500, C1000H, C2000H, CQM1, and CVM1) Protocol Support Software (PSS) Motion Control Support Software (MCSS) -- for C200H-MC221 Motion Control Module ONLY 138 ITEM DESCRIPTION PART NUMBER Motion Control Support Software 3.5”, 2HD for IBM PC/AT compatible CV500-ZN3AT1-E U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met.  MANUALS PLC Installation, Operation ITEM DESCRIPTION PART NUMBER C200HX/C200HG/C200HE PLCs C200HX/C200HG/C200HE PLCs C200HW-COM01-C200HW-COM06-E C200HW-ZW3AT1-E Protocol Software Installation Guide Operation Guide Operation Guide Operation Guide W302 W303 W304 W305 ITEM DESCRIPTION PART NUMBER C200H-PCU01/PCS01 C200H-ASC02 C200H-AD001, C200H-DA001 C200H-AD002 C200H-DA002 C200H-CT001-V1/CT002 C200H-CT021 C200H-TS001/TS002 C200H-TC PC Card Module ASCII/BASIC Module Analog I/O Modules Analog Input Module Analog Output Module High-speed Counter Modules High-speed Counter Modules Temperature Sensor Input Modules Temperature Control Module W313 W165 W127 W229 W260 W141 W311 W124 W225 C200H-TV Heat/Cool Temperature Control Module W240 PID Control Module W241 Cam Positioner Module Position Control Module Position Control Module Position Control Module ID Sensor Module Voice Module Motion Module Fuzzy Logic Module W224 W137 W128 W166 W153 W172 W314 / W315 / W256 W208 DESCRIPTION PART NUMBER SYSMAC Link Modules SYSMAC Net Module PC Link Module Host Link Modules System manual System manual System manual W174 W114 W135 W143 W120 W136 W267 DESCRIPTION PART NUMBER Operation manual W173 W84 Operation manual Operation manual Procedures for programming EPROM Procedures for interfacing with floppy disk W150 W107 W155 W119 ITEM DESCRIPTION PART NUMBER SYSMAC Support Software SYSWIN Support Software Programming procedures using SSS Programming procedures using SYSWIN W247/W248 SYSWIN-EMAN-V Special I/O Modules   C200H-PID C200H-CP114 C200H-NC111 C200H-NC112 C200H-NC221 C200H-IDS01/IDS21 C200H-OV001 C200H-MC221 C200H-FZ001 Communications ITEM  C200HW-SLK C200HS-SNT32 C200H-LK401 C200H-LK20 SYSBUS Wired Remote I/O SYSBUS Fiber-Optic Remote I/O DeviceNet  Peripheral Devices ITEM C200H-DAC01 GPC (Graphics Programming Console) FIT (Factory Intelligent Terminal) Printer Interface Module PROM Writer Operation Guide Floppy Disk Interface Module Programming Software U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL, CSA, NK, LLOYD, and CE standards were met.  139  140 COMPLEMENTARY PRODUCTS COMPLEMENTARY 141 PRODUCTS Operator Interface Terminals 142 141 COMPLEMENTARY PRODUCTS OPERATOR INTERFACE TERMINALS Easy to order, with no complicated configuration (communications and memory are built-in), the NT Series Terminals provide a variety of control options. From the basic 4 line x 20 character, text-based NT11S to our graphic touch screen models — including the slim NT20S (with a depth of only 54 mm) and the eight-color NT620C — our new line of terminals can be relied on for clear, dependable data presentation. And with Omron’s Host Link and NT Link communication methods, fast response times between terminal and PLC are guaranteed. Direct connection to the C200H backplane is also available on some models for an even faster response. Combine this with Omron’s NT Support Software and you get a powerful operator interface that’s easy to read and quick to connect with screens that are simple to create. MODEL NT11S NT20S NT30 NT30C DISPLAY Size 4 line x 20 character 5" diagonal 5.7" diagonal 5.7" diagonal Type Backlit LCD Backlit STN LCD Bicolor backlit STN LCD 8-color backlit STN LCD Resolution 160 x 64 pixels 256 x 128 pixels 320 x 240 pixels 320 x 240 pixels Interface Alphanumeric Touch screen Touch screen Touch screen Touch cells — 72 per screen 192 per screen 192 per screen Large characters Slim profile Bicolor display 8-color display Contrast control Easy to configure screens Full graphic capabilities Full graphic capabilities Password protect screens Replaceable backlight Replaceable backlight Replaceable backlight Type Flash EPROM Flash EPROM Flash EPROM Flash EPROM Size 32 K 64-92 K 512 K 512 K 250 screens 250 screens 2000 screens 2000 screens Communication Host Link / NT Link Host Link / NT Link / C200H Interface Host Link / NT Link Host Link / NT Link Overall Dimensions 218W x 113H x 38.2D mm 8.58W x 4.45H x 1.50D in 190W x 110H x 58D mm 7.48W x 4.33H x 2.28D in 195W x 142H x 55.6D mm 7.68W x 5.59H x 2.19D in 195W x 142H x 55.6D mm 7.68W x 5.59H x 2.19D in Ratings NEMA 4 NEMA 4 NEMA 4 NEMA 4 Approvals UL / CSA UL / CSA UL / CSA UL / CSA — Backlight Backlight Backlight Chemical resistant cover Chemical resistant cover Chemical resistant cover Protective sheet Protective sheet Protective sheet C200H Interface B7A Interface B7A Interface FEATURES MEMORY Max. # of screens GRAPHIC CAPABILITIES Freeform drawing Bitmap Tiling Bar graph Line trending Thumbwheel switch Text and numeric Real-Time Clock Printer Port ENVIRONMENTAL Accessories 142 COMPLEMENTARY PRODUCTS OPERATOR INTERFACE TERMINALS MODEL NT600S (LCD) NT600S (EL) NT620S NT620C Size 9" diagonal 9" diagonal 9" diagonal 9.7" diagonal Type Backlit STN LCD Electroluminescent Electroluminescent 8-color backlit STN LCD Resolution 640 x 400 pixels 640 x 400 pixels 640 x 400 pixels 640 x 480 pixels Interface Touch screen Touch screen Touch screen Touch screen Touch cells 128 per screen 128 per screen 512 per screen 768 per screen Large screen Clear EL display Clear EL display 8-color display Slim profile Extra-wide viewing angle Full graphic capabilities Full graphic capabilities Replaceable backlight Slim profile Extra-wide viewing angle Replaceable backlight DISPLAY FEATURES MEMORY Type Flash EPROM Flash EPROM Flash EPROM Flash EPROM Size 128 K 128 K 512 K 1 MB 500 screens 500 screens 2000 screens 2000 screens Communication Host Link / NT Link C200H Interface Host Link / NT Link / C200H Interface Host Link / NT Link Host Link / NT Link Overall Dimensions 275W x 192H x 71D mm 10.83W x 7.56H x 2.80D in 275W x 192H x 71D mm 10.83W x 7.56H x 2.80D in 275W x 192H x 71D mm 10.83W x 7.56H x 2.80D in 275W x 196H x 76.8D mm 10.83W x 7.72H x 3.02D in Ratings NEMA 4 NEMA 4 NEMA 4 NEMA 4 Approvals UL / CSA UL / CSA UL / CSA UL / CSA Accessories Backlight Chemical resistant cover Chemical resistant cover Backlight Chemical resistant cover Protective sheet Protective sheet Chemical resistant cover Protective sheet C200H Interface Max. # of screens GRAPHIC CAPABILITIES Freeform drawing Bitmap Tiling Bar graph Line trending Thumbwheel switch Text and numeric Real-Time Clock Printer Port ENVIRONMENTAL C200H Interface Protective sheet 143  OPERATOR INTERFACE TERMINAL COMMUNICATIONS OPTIONS Direct Access Function greatly reduces programming effort of the host. The Direct Access Function enables the user to directly access the relay area and DM area of the Host. Using this function, the user can greatly reduce the PLC programming effort that is required for the Operator Interface Terminals. The C200HX/HG/HE Interface and NT Link are ideal for applications that require high-speed input operations. NT Link 1:1 NT Link • Greatly reduces ladder programming required for controlling the Operator Interface Terminals. Host • Enables a faster I/O response by using a dedicated communications protocol. RS-232C port 15 m max. Operator Interface Terminal RS-422 Host Link Connection • Greatly reduces ladder programming required for controlling the Operator Interface Terminals. Host • Ideal for a long-distance transmission with 1:1 connection. Host Link Module RS-422 Cable 500 m max. CPU Operator Interface Terminal RS-232C Host Link Connection • Greatly reduces ladder programming required for controlling the Operator Interface Terminals. Host • One of the most popular communications systems. Host Link Module Host Link Cable Distance: 15 m max. CPU Operator Interface Terminal C200H Backplane Connection Host • Greatly reduces ladder programming required for controlling the Operator Interface Terminals. I/O Expansion Port • Directly connects to the I/O expansion port of the C200HX/HG/HE to achieve faster response and high-speed display. I/O Expansion Cable 10 m max. Operator Interface Terminal 144 • No Communications Units are required on the C200HX/HG/HE side.  OPERATOR INTERFACE TERMINAL COMMUNICATIONS OPTIONS Communications Methods Applicable to C200HX/HG/HE  Possible to connect to the I/O expansion port  Possible to use from the Communications Module built into the CPU (see note)  Possible to connect to the Communications Module DIRECT ACCESS FUNCTION PLC C RS-232C HOST LINK CONNECTION C200HX/HG/HE Note: / C200H BACKPLANE CONNECTION  NT LINK  RS-422 HOST LINK CONNECTION / C200HE-CPU42-E, C200HG-CPU43-E/63-E, and C200HX-CPU44-E/64-E allow connection to the built-in port. Communications Methods of the NT Series OPERATOR O O INTERFACE TERMINAL DIRECT ACCESS FUNCTION RS-232C HOST LINK CONNECTION C200H BACKPLANE CONNECTION NT LINK RS-422 HOST LINK CONNECTION NT11S Yes --- Yes Yes NT20S Yes Yes Yes --- NT30/C Yes --- Yes Yes NT600S Yes Yes Yes --- NT620S/C Yes --- Yes --- 145  I/O BLOCKS I/O Blocks Connect to High-density I/O Modules, Mixed I/O Modules and Normal I/O Modules Connecting to High-density I/O Modules C200H-ID215 C200H-OD215 C200H-MD215 G70A I/O Block* G79 Connecting Cable G7VC Output Block G70A I/O Blocks • G70A I/O Blocks provide16 contact input or 16 contact output points in a compact package (234 x 75 x 64 mm). • They mount to DIN track to save installation and maintenance time. G7VC Output Blocks • G7VC Output Blocks provide 16 output points in a compact package (192 x 58 x 38.5 mm). Connecting to Group-2 I/O Modules • A rotating front cover provides easy access to terminals for simplified maintenance and increased safety. C200H-ID216 C200H-ID217 C200H-OD218 C200H-OD219 II I IV G79-I or G79-O Connecting Cable G70A I/O Block* III G7VC Output Block Note: I to IV indicate connector numbers. Connecting to I/O Modules Equipped with Connectors C200H-OD215 C200H-MD215 G70A-ZOC16-3 I/O Block with Relays G79 Connecting Cable (1:1) 146  G72C/G72C-V I/O TERMINALS G72C/G72C-V I/O Terminals In Remote I/O Systems I/O Terminals are connected as Slaves in Remote I/O Systems to provide for special wiring needs via wiring blocks. Compactness in the right shape is provided by a choice between flat terminals (182 x 85 x 45 mm) and vertical terminals (202 x 45 x 63 mm). C200H-RM201 Remote I/O Master Module G72C-VID16 G72C-VOD16 G72C-ID16 G72C-OD16 G70A-ZOC16-3 Valve wiring block (Not sold by OMRON.) G71-OD16 Note: Ask your OMRON dealer for more information concerning OMRON I/O Blocks and I/O Terminals. 147  CONNECTOR TERMINAL CONVERSION UNITS/CABLES Connecting Cables A For 32-point I/O Modules with Connectors: XW2ZNote:  The G79- C (Cable for G7TC) cannot be used for the XW2C. You Can Easily Convert Between Connectors and Terminal Blocks to Simplify Control Wiring. XW2B • Only 45 mm wide, the XW2B connects directly to PLC I/O • Modules using special cables to simplify connection. • Snap onto DIN rail or mount with screws. • Easy panel-mounting. XW2Z • A special cable for easy connection between PLC I/O Modules and Connector--Terminal Conversion Units For 32-point I/O Modules with Connectors (Group-2 Slaves) or B For 64-point I/O Modules with Connectors : Connection Examples XW2Z- 32-point PLC I/O Modules with Connectors  XW2ZA Connecting Cable For 32-point Input Modules with Connectors (Group-2 Slaves) or For 64-point Input Modules with Connectors : D XW2ZNote: C200H-ID215 C200H-OD215 C200H-MD115 C200H-MD215 C200H-MD501 C200H-ID501 C200H-OD501  XW2B-20G   (Cable for G7TC) cannot be used for the XW2C. The G79-1 C- F Cable with Loose Crimp Connectors (20 connections) : 32-point I/O Modules with Connectors (Group-2 Slaves) 64-point I/O Modules with Connectors (Group-2 Slaves) C200H-ID216 C200H-OD218 C200H-ID217 C200H-OD219 XW2Z-  XW2B-40G I/O Modules with Terminal Blocks  XW2ZF Cable with Loose Crimp Connectors  XW2B-20G 148 PART NUMBER INDEX PART NUMBER INDEX 149 149  PART NUMBER INDEX C200HW--COM05--E . . . . . . . . . . . . . 14, 124 C200H--TS101 . . . . . . . . . . . . . . .42, 43, 127 C200HW--COM06--E . . . . . . . . . . . . . 14, 124 C200H--TV00_ . . . . . . . . . . . . . . .46, 47, 128 C200HW--DRM21 . . . . . . . . . . . . . . . .81, 131 C200H--TV10_ . . . . . . . . . . . . . . .46, 47, 128 C200HW--ME04K . . . . . . . . . . . . . . . .17, 124 C200HIA222 . . . . . . . . . . . . . . . . . . . .23, 126 C200HW--ME08K . . . . . . . . . . . . . . . .17, 124 C200HS--CN220--EU . . . . . . . . . . . . . . . . . 98 C200HW--ME16K . . . . . . . . . . . . . . . .17, 124 G6B--1174P--FD--US . . . . . . . . . . . . . . . . 136 C200HS--CN222 . . . . . . . . . . . . . . . . . . . .135 C200HW--ME32K . . . . . . . . . . . . . . . .17, 124 G71--IC16 . . . . . . . . . . . . . . . . . . . . . . . . .125 C200HS--CN229--EU . . . . . . . . . . . . . . . . . 98 C200HW--P___ . . . . . . . . . . . . . . . . . .17, 124 G71--OD16 . . . . . . . . . . . . . . . . . . . . . . . .125 C200HS--CN422 . . . . . . . . . . . . . . . . . . . .135 C200HW--PA204. . . . . . . . . . . . .18, 124, 125 G7TC--IA16 . . . . . . . . . . . . . . . . . . . . . . . .125 C200HS--INT01 . . . . . . . . . . . . . .31, 32, 126 C200HW--PA204S . . . . . . . . . . . 18, 124, 125 G7TC--ID16 . . . . . . . . . . . . . . . . . . . . . . . .125 C200HS--MP16K . . . . . . . . . . . . . . . .17, 124 C200HW--PCS01--E . . . . . . . . 72, 73, 74, 131 G7TC--OC16 . . . . . . . . . . . . . . . . . . . . . . .125 C200HS--SNT32 . . . . . . . . . . . . . .75, 76, 131 C200HW--PCU01--E . . . . . . . . 72, 73, 74, 131 C200HW--ATT32. . . . . . . . . . . . . . . . . . . .136 C200HW--PD024 . . . . . . . . . . . .18, 124, 125 C200HW--ATT52. . . . . . . . . . . . . . . . . . . .136 C200HW--SLK13/14 . . . . . . . . 78, 79, 80, 131 PFP--100N . . . . . . . . . . . . . . . . . . . . . . . . .137 C200HW--SLK23/24 . . . . . . . . 78, 79, 80, 131 PFP--100N2 . . . . . . . . . . . . . . . . . . . . . . . .137 C200HW--ZW3AT1--E . . . . . . . . . . . . . . . 138 PFP--50N . . . . . . . . . . . . . . . . . . . . . . . . . .137 C500--CE241 . . . . . . . . . . . . . . . . . . . . . . .130 PFP--M . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 C500--CE242 . . . . . . . . . . . . . . . . . . . . . . .130 PFP--S . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 C200HW--ATT82. . . . . . . . . . . . . . . . . . . .136 C200HW--ATTA2 . . . . . . . . . . . . . . . . . . .136 C200HW--BC031 . . . . . . . . . . . . . . . .19, 124 C200HW--BC051 . . . . . . . . . . . . . . . .19, 124 C200HW--BC081 . . . . . . . . . . . . . . . .19, 124 C200HW--BC101 . . . . . . . . . . . . . . . .19, 124 C200HW--BI031 . . . . . . . . . . . . . . . . . . . . .19 C200HW--BI051 . . . . . . . . . . . . . . . . . . . . .19 C200HW--BI081 . . . . . . . . . . . . . . . . . . . . .19 C200HW--BI101 . . . . . . . . . . . . . . . . . . . . .19 C200HW--CE001 . . . . . . 75, 76, 78, 80, 131 C200HW--CE002 . . . . . . 75, 76, 78, 80, 131 C200HW--CE011 . . . . . . . . . .72, 73, 74, 131 C200HW--CE012 . . . . . . . . . .72, 73, 74, 131 C200HW--COM01 . . . 14, 75, 76, 78, 80, 124 C200HW--COM02 . . . . . . . . . . . . . . . .14, 124 C200HW--COM03 . . . . . . . . . . . . . . . .14, 124 C200HW--COM04--E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 75, 76, 78, 80, 124 152 F C200H--TS001 . . . . . . . . . . . . . . .42, 43, 127 C500--CE243 . . . . . . . . . . . . . . . . . . . . . . .130 FCS-CAK6230-US . . . . . . . . . . . . . . . . . . 133 FCS-HCR-_ _ -_ _ _ . . . . . . . . . . . . . . . . . 133 G P S C500--CE244 . . . . . . . . . . . . . . . . . . . . . . .130 C500--CE401 . . . . . . . . . . . . . . . . . . .130, 136 C500--CE402 . . . . . . . . . . . . . . . . . . .130, 136 C500--CE403 . . . . . . . . . . . . . . . . . . .130, 136 C500--CE404 . . . . . . . . . . . . . . . . . . . . . . .130 C500--CE405 . . . . . . . . . . . . . . . . . . . . . . .136 C500--COV02 . . . . . . . . . . . . . . . . . . . . . .136 S300--COCH82 . . . . . . . . . . . . . . . . . . . . .133 S3200--COCF2011 . . . . . . . . . . . . . . . . . . 133 S3200--COCF2511 . . . . . . . . . . . . . . . . . . 133 S3200--COCF62F . . . . . . . . . . . . . . . . . . .133 S3200--COCF62M . . . . . . . . . . . . . . . . . . 133 S3200--COCH62M . . . . . . . . . . . . . . . . . . 133 S3200--COIAT2000 . . . . . . . . . . . . . . . . . 133 C500--Z3AT1--EV1.2 . . . . . . . . . . . . . . . . 138 S3200--NSB11--E . . . . . . . . . . . . . . . . . . .132 CQM1--CIF02 . . . . . . . . . . . . . . .98, 129, 135 SYSWINHL--V3.0 . . . . . . . . . . . . . . . . . . .138 CQM1--PRO01--E . . . . . . . . . . . . . . . .98, 135 CV500--CN244 . . . . . . . . . . . . . . . . . . . . .129 X CV500--ZN3AT1--E . . . . . . . . . . . . . . 129, 138 XW2B--20J6--6 . . . . . . . . . . . . . . . . . . . . .129 CVM1--PRS71 . . . . . . . . . . . . . . . . . . . . . .129 XW2Z--100J--F1 . . . . . . . . . . . . . . . . . . . .129
C200H-TV003 价格&库存

很抱歉,暂时无法提供与“C200H-TV003”相匹配的价格&库存,您可以联系我们找货

免费人工找货