INTRODUCTION
M O R E P O W E R . M O R E F L E X I B I L I T Y. M O R E S P E E D .
Like our popular C200H/HS mid-size PLC series, Omron’s new C200Hα
series offers the advantages of large PLC performance and I/O versatility
in a mid-size PLC package and price range. But there’s more to the
new C200Hα series—a lot more.
WHY OMRON?
Improvements to the existing series, such as greater memory capacity
and faster processing speed, strengthen the C200Hα series’ capabilities
as a controller. Newly added features, such as a protocol macro and
an optional PCMCIA Card Module, transform the C200Hα series
into a powerful on-site data processing system—and transforms
your workplace into a highly responsive, information-based operation.
Your 24-Hour Automation Solution
880
1,184 maximum
More Special I/O Modules
C200HS
10
C200Hα
16
Increased Processing Speed
0.375 µs LD execution
0.1µs LD execution speed
C200HS
C200Hα
Increased Memory Capacity
C200HS
15.2k words
C200Hα
31.2k words maximum
Increased Data Memory
C200HS
6K words
C200Hα
24K words maximum
Enlarged SYSMAC LINK Data Link Area
C200HS
C200Hα
918 words
2,966 words
Increased Local Expansion
C200HS
C200Hα
Omron performs 100% quality inspection and testing procedures
at every stage of manufacturing – your assurance of satisfaction.
Get Omron’s SmartFactory advantage by utilizing our application
engineering know-how, extensive training, and 24-hour technical
support from anywhere in the USA. Through our commitment to
flexible manufacturing, Omron has become a leader in the manufacture
of Sensors, Digital Panel Meters, Digital Displays, Counters, Timers,
PLCs, Process and Temperature Controllers, and other control
devices.
Technical Information FAST
More I/O Points
C200HS
C200Hα
Quality Recognized Industry-Wide
2 expansion backplanes max.
3 expansion backplanes max.
Obtain up-to-date technical specifications for all Omron products
24 hours a day, 7 days a week from your fax machine. Call our
ControlFax at 847.843.1963. Request #50 for a directory of
all documents available.
Information is also available on the internet. Visit our web site at
http://oei.omron.com and get the latest information on Omron
products and literature.
Worldwide Sales and Support Network
You’ll find over 200 stocking distributors and local sales offices
across the United States. With distributors in Canada and Mexico,
and branch offices worldwide, Omron provides replacement
components, service and multilingual documentation virtually
anywhere in the world.
Expertise You Can Rely On
You can rely on the high quality PLC products you’ve come to
expect from Omron. Trust our nationwide network of local stocking
distributors and system integrators to offer expertise you can
depend on. Just give us a call.
TABLE OF CONTENTS
SECTION
PAGE NUMBER
SYSTEM COMPONENTS
1
System Overview
Introduction
2
Overview
6
PLC System specifications
8
CPU
Features
9
Selection Guide
10
Specifications and Characteristics
11
Communication Boards
14
Protocol Macro Function
15
Memory Cassettes
17
Power Supply Modules
18
Backplanes
19
Connecting I/O Cables
21
Discrete I/O Modules
22
Special I/O Modules
26
COMMUNICATIONS
Overview
Communication Modules
Fiber-optic Cable and Connections
69
70
72
89
PROGRAMMING
Programming Software
SSS and SYSWIN
Protocol Support Software
Programming Peripherals and Cables
Programming Instructions
91
92
94
97
99
STANDARD PARTS
123
COMPLEMENTARY
141
PRODUCTS
Operator Interface Terminals
PART NUMBER INDEX
142
149
NOTE: Specifications to change without notice.
Warranty: Omron certifies all of its products either meet
or exceed stipulated specifications. Omron is not liable
for stenographic and/or clerical errors.
Omron's obligation under this warranty is limited solely
to repair or replacement at Omron's discretion. Omron
will not be liable for any design furnished by Buyer and
incorporated into equipment.
This warranty is voided if the product is altered in any
way or suffers consequential damage due to negligence
or misuse.
Omron is not to suffer risk due to the suitability or
unsuitability or the results of the use of its products used
in combination with any electrical or electronic
components, circuits, systems assemblies or any other
materials or substances or environments.
The foregoing warning is the only warranty which Omron
Electronics, Inc., provides with respect to the products
listed herein. No other warranties, expressed, implied,
or statutory shall apply, whether as to merchantability,
fitness for a particular purpose, description, or otherwise.
Limitation of Liability: Notwithstanding any other
statement herein, Omron Electronics, Inc., its contractors
and suppliers, shall not be liable for any special, indirect,
incidental or consequential damages. The remedies of
the purchaser set forth herein are exclusive where so
stated and the total cumulative liability of Omron
Electronics, Inc., its contractors and suppliers, with
respect to this contract or anything done in connection
therewith, shall not exceed replacement price
reimbursement as to the product on which such liability
is based.
SYSTEM COMPONENTS
SYSTEM COMPONENTS
System Overview
Introduction
Overview
PLC System specifications
CPU
Features
Selection Guide
Specifications and Characteristics
Communication Boards
Protocol Macro Function
Memory Cassettes
Power Supply Modules
Backplanes
Connecting I/O Cables
Discrete I/O Modules
Special I/O Modules
1
2
6
8
9
10
11
14
15
17
18
19
21
22
26
1
SYSTEM COMPONENTS
The New C200Hα Series:
Powerful Mid-Sized Machine Control, Powerful Onsite Data Processing
Migrate Easily
While the functions and capabilities of the
C200Hα series have been dramatically
enhanced, common languages and I/O
units allow smooth migration from
C200H/HS PLCs.
Improved Special
I/O Modules
The maximum number of Special I/O
Modules that can be mounted on the CPU
has been increased from 10 to 16 modules.
You can easily manage a control system
with the right combination of Special I/O
Modules.
The intelligent I/O read and intelligent I/O
write instructions can be executed to
transfer more than one word of data. All
of the C200HS Special I/O Modules can
be used without any modification. In
addition, a PC Card Module, Motion
Control Module, and Two-axis High-speed
Counter Module have been added.
A Built-in Protocol
Macro Function
Previously, it was necessary to write a
communications program for the ASCII
Module or BASIC Module whenever a
measurement device or component was
connected to the PLC. The C200H Alpha
PLCs are equipped with the Protocol
Macro Function which incorporates these
communications programs into the ladder
program with just a few ladder instructions.
A variety of workplace data can be
processed in real-time improving quality
and reducing total product cost. System
development time can be reduced
substantially.
2
Interface to Memory
or Ethernet via PC
Card Module
The PC Card Module provides two
PCMCIA interface slots. Either two type I
or II or one type III PC card can be installed.
The system accepts SRAM, FLASH and
ATA cards.
PC File Operations: C200HX/HG/HE
memory contents may be written to
memory cards as files using ladderdiagram instructions. File contents can be
compared and searched and word data
can be separated by commas in the file
format so that commercially available
spreadsheets may be used.
Ethernet Connection: Using an Ethernet
PCMCIA card, data may be exchanged
using Omron’s FINS protocol via UDP/IP.
SYSTEM COMPONENTS
Build Networks
Easily with the
Alpha’s Built-in
Features.
Using built-in Host Link function of the
C200H Apha, connect directly to operator
interface terminals using a cable as an
interface, or use a One-to One data links
between alpha PLCs are just as easy to
make.
When networking with a PC, the TXD and
RXD instructions can be used to carry out
RS-232C communications from the PLC,
and the STUP instruction can be used to
switch between Host Link and RS-232C,
communications.
Open up Your
Communications
Possibilities in All
Three Automation
Network Levels
DEVICE LEVEL NETWORKS: The new
C200HW-DRM21 Module supports
DeviceNet open multi-vendor network
communications. DeviceNet makes it
possible to connect devices that have a
wide variety of parameters or data, such
as inverters or analog devices. It also
allows other DeviceNet products to be
connected as well.
CONTROL LEVEL NETWORKS: Omron's
SYSMAC Link and SYSMAC Net networks
provide high-speed real-time data transfer.
SYSMAC Link’s data link capacity has
been increased from 918 words to 2,966
words.
Connect to a Variety
of Serial Devices
The C200Hα CPU's can be equipped with
one of six communication boards. By
installing the appropriate communication
board, the CPU can communicate with
SYSMAC Link / SYSMAC Net modules, a
PC Card module or serial devices. Using
the Protocol Macro Function built into the
C200HW-COM04-E, C200HW-COM05-E
or C200HW-COM06-E communications
boards, communications sequences for
one of seven types of installed Omron
protocols may be used or customized for
a modem, operator interface, bar code
reader, temperature controller, or any kind
of RS-232C, RS-422 or RS-485 device.
INFORMATION LEVEL NETWORKS: The
C200HW-PCS01 PCMCIA Module allows
data exchange with CV Ethernet units,
PCs and workstations using Omron’s FINS
protocol via Ethernet UDP/IP.
3
SYSTEM COMPONENTS
BUILD YOUR
OWN CONTROL
AND DATA
PROCESSING
SYSTEM
CPU RACK
CPU
Choose from 11 CPU models
p.19
CPU BACKPLANE
C200HW-BC031
C200HW-BC051
C200HW-BC081
C200HW-BC101
Separate CPU and power supply
CPU and Expansion
Backplanes
CPU and power supply mount on
a dedicated CPU backplanes
Local expansion may be done
with the new space-saving
C200Hα expansion backplanes
or current C200H backplanes
Connect up to 5 remote I/O
backplanes
Special I/O
Take full advantage of the
C200Hα’s power with any
combination of 20 Special I/O
Modules
p.17
p.9
EEPROM MEMORY CASSETTES
4K words
C200HW-ME04K
8K words
C200HW-ME08K
16K words
C200HW-ME16K
32K words
C200HW-ME32K
EPROM MEMORY CASSETTES
16/32K words
C200HS-MP16K
CPUs
C200HE-CPU11-E
C200HE-CPU32-E C200HE-CPU42-E
C200HG-CPU33-E
C200HG-CPU43-E
C200HG-CPU53-E
C200HG-CPU63-E
C200HX-CPU34-E
C200HX-CPU44-E
C200HX-CPU54-E
C200HX-CPU64-E
p.18
POWER SUPPLY
MODULE
C200HW-PA204
C200HW-PA204S
C200HW-PD024
EXPANSION I/O RACK
Communications
All CPUs include a multifunctional
peripheral port to communicate
to programming peripherals
Standard Host Link port is built
into selected CPUs
One of six communications
boards can also be installed in
the CPU. When used with the
protocol macro function, these
boards provide a simple way to
connect with a SYSMAC Link or
SYSMAC Net Link module, to
communicate with a Modem,
operator interface, bar code
reader, Process Controller or any
kind of RS-232C, RS-422 or RS485 device.
p.21
p.18
p.19
I/O CONNECTING
CABLE
C200H-CN❏❏1
(30cm,70cm,2m,5m,10m)
POWER SUPPLY
MODULE
C200HW-PA204
C200HW-PA204S
C200HW-PD024
EXPANSION 1/O BACKPLANE
C200HW-BI031
C200HW-BI051
C200HW-BI081
C200HW-BI101
SLAVE RACKS
Software Support
Supported by both SYSMAC
Support Software Version 1.2 or
greater and SYSWIN version 3.0
or greater
4
p.84
p.20
REMOTE I/O SLAVE MODULE
Fiber-optic, 100/200 VAC C200H-RT001-P
Fiber-optic, 24 VDC
C200H-RT002-P
Wired, 100/200 VAC
C200H-RT201
Wired, 24 VDC
C200H-RT202
SLAVE I/O BACKPLANE
C200H-BC031-V2
C200H-BC051-V2
C200H-BC081-V2
C200H-BC101-V2
SYSTEM COMPONENTS
COMMUNICATIONS BOARDS
p.14
p.14
C200HW-COM01
C200HW-COM02
(cannot be mounted to the CPUHE-CPU11-E)
p.14
p.14
C200HW-COM03
C200HW-COM04-E
p.14
p.14
C200HW-COM05-E
C200HW-COM06-E
COMMUNICATIONS MODULES
p.81
DEVICENET
SCANNER
C200HW-DRM21
p.85
p.87
HOST LINK
RS422
C200H-LK202-V1
Fiber-optic C200H-LK101-PV1
RS232
C200H-RM201-V1
p.72
PC LINK
C200H-LK401
p.83
PC CARD*
C200HW-PCU01
Ethernet Set*
C200HW-PCS01-E
REMOTE I/O MASTER
Fiber-optic
C200H-RM001-V1
Wired
C200H-RM201-V1
p.78
SYSMAC LINK*
Coaxial
C200HW-SLK23/24
Fiber-optic
C200HW-SLK13/14
p.75
SYSMAC NET LINK*
C200HS-SNT32
*Use these modules together with communications boards (C200H-COM01/04-E) in the CPU Rack.
SPECIAL I/O MODULES
p.40
p.41
p.62
p.60
p.51
p.58
p.66
ANALOG INPUT
C200H-AD001
C200H-AD002
ANALOG OUTPUT
C200H-DA001
C200H-DA002
ASCII/BASIC
C200H-ASC02
CAM POSITIONER
C200H-CP114
FUZZY LOGIC
C200H-FZ001
HIGH-SPEED
COUNTER
C200H-CT❏❏❏
RFID SENSOR
C200H-IDS❏❏
p.53
p.48
p.56
p.42
p.44,46
DUAL-AXIS
MOTION CONTROL
C200H-MC221
PID CONTROL
C200H-PID0❏
POSITION
CONTROL
C200H-NC211
C200H-NC112
TEMPERATURE
SENSOR
C200H-TS❏❏❏
TEMPERATURE
CONTROL
C200H-TC❏❏❏
C200H-TV❏❏❏
p.26
p.64
VOICE
C200H-OV001
B7A INTERFACE
16 points
C200H-B7A❏1
p.26
p.29,34
p.30,36
p.31
p.38
p.32
B7A INTERFACE
32 points/64 points
C200H-B7A❏❏
HIGH DENSITY INPUT
C200H-ID❏❏❏
Group 2 C200H-ID21❏
HIGH DENSITY OUTPUT
C200H-OD❏❏❏
Group 2 C200H-OD21❏
ANALOG TIMER
C200H-TM001
MIXED I/O
16 inputs/16 outputs
C200H-MD❏❏❏
INTERRUPT INPUT
C200HS-INT01
(CPU Backplane ONLY)
(cannot be used on Slave rack)
DISCRETE I/O MODULES
p.22
p.22
p.22
p.22
8 POINT INPUT
C200H-I❏❏❏❏
16/32 POINT INPUT
C200H-I❏❏❏❏
5/8/16 POINT OUTPUT
C200H-O❏❏❏❏
12/32 POINT OUTPUT
C200H-O❏❏❏❏
5
SYSTEM OVERVIEW
BASIC CONFIGURATION -- C200HX/HG/HE
CPU Rack
I/O Connecting Cable
Backplane
I/O Modules
Special I/O Modules
Communication
Modules
CPU
Power Supply
Module
NOTE:
Memory
Cassette
Communications Board
SELECT THE APPROPRIATE BACKPLANE FOR THE CPU RACK,
EXPANSION I/O RACK, AND SLAVE RACK. EACH TYPE OF
BACKPLANE IS A DIFFERENT MODEL.
For blackplane dimensions, refer to the Backplanes
subsection found later in this section.
To order, refer to the specific information provided
separately in the Standard Parts section of this catalog.
CPU Rack
The CPU Rack is the master controller rack for the control systems and contains the system communications ports. It may be
expanded using Expansion Racks and Slave Racks.
A fully configured C200Hα CPU Rack includes a CPU, Backplane,
Power Supply Module, I/O Modules, Special I/O Modules and
Communication Modules, as appropriate for the application.
A complete system may also include connecting cables and programming software or hardware.
A total of two SYSMAC LINK or SYSMAC NET Link Modules can
be mounted to the CPU if the C200HW-COM01 or C200HWCOM04-E Communications Board is connected to the CPU.
Only two C200HS-INT01 Interrupt Input Modules can be mounted
on a CPU Rack.
6
SYSTEM OVERVIEW
BASIC CONFIGURATION -- C200HX/HG/HE
Slave Racks
Expansion I/O Racks
Backplane
I/O Modules
Special I/O Modules
Communication Modules
Fiber-optic
cable or
twisted-pair
cable
I/O Modules and
Special I/O Modules
Power Supply
Module
Remote I/O
Slave Module
Local Expansion Racks
Slave Racks
The configuration of an Expansion I/O Rack includes a
Power Supply Module, an Expansion Backplane, and appropriate I/O Modules, Special I/O Modules, and Communication Modules.
The number of allowable Expansion Racks varies with
CPU model.
Up to three Expansion I/O Racks can be connected to the
C200HX-CPU54-E, C200HX-CPU64-E, C200HGCPU53-E, or C200HG-CPU63-E.
Up to two Expansion I/O Racks can be connected to any
other CPU for the C200HX, C200HG, and C200HE.
Different types of Backplanes are necessary for the CPU,
Expansion I/O Rack, and the Slave Rack.
To expand a system and minimize wiring costs, you may
connect a maximum of five Slave Racks per system.
The Configuration of a Slave Rack includes a Remote I/O
Slave Module, a Backplane (for the C200HX/HG/HE Slave
Rack), I/O Modules, and Special I/O Modules.
To mount a High-density I/O Module to a Slave Rack, use a
C200H-RM001-PV1/RM201.
Note: C200H-RM001-P Master Modules cannot be used.
Group-2 High-density I/O Modules, Communications I/O
Modules, and Interrupt Input Modules cannot be mounted in
Slave Racks.
You can connect a Maximum of two Expansion I/O Racks to
Slave Racks using I/O Connecting Cable.
Always count the Expansion I/O Racks (connected in this
way) against the maximum of five Slave Racks that can be
connected.
7
SYSTEM OVERVIEW
C200HX/HG/HE SPECIFICATIONS
C200Hα PLC -- System Specifications
ITEM
SPECIFICATIONS
Supply voltage
AC power supply: 100 to 120/200 to 240 VAC selectable 50/60 Hz
DC power supply: 24 VDC
Operating voltage range
AC power supply: 85 to 132/170 to 264 VAC
DC power supply: 19.2 to 28.8 VDC
Power consumption
AC power supply: 120 VA max.
DC power supply: 50 W max.
Surge current
30 A max.
Output capacity
4.6 A, 5 VDC; 0.6 A, 26 VDC; 0.8 A, 24 VDC+10%/--20% (C200HW-PA204S only)
Insulation resistance
20 MΩ between AC terminals and the GR terminal at 500 VDC (see note 1)
Dielectric strength
2,300 VAC at 50/60 Hz for 1 minute between AC terminals and housing; 1,000 VAC at 50/60 Hz for 1 minute between DC terminals and housing. Leakage current: 10 mA max. (see note 1)
Noise immunity
1,500 Vp-p, pulse width: 100 ns to 1 µs, rise time: 1 ns pulse (by noise simulator)
Vibration
10 to 57 Hz; 0.075 mm amplitude, 57 to 150 Hz; acceleration: 1 G, in X, Y, and Z directions, for 80 minutes each (sweep time 8
min x 10 sweeps = 80 min); (When mounted on DIN track, 2 to 55 Hz, 0.3 G, in X, Y, and Z directions for 20 minutes each)
Shock
15G (147 m/s2) in X, Y, and Z directions, 3 times each
Ambient temperature
Operating: 0 to 55°C (32°to 131.0°F)
Storage: --20 to 75°C (-4.0 to 167.0°F) without battery
Humidity
10% to 90% (without condensation)
Atmosphere
Must be free of corrosive gases
Grounding
Less than 100 Ω
Enclosure rating
IEC IP30 (mounted in a panel)
Weight
6 kg max. (CPU: 315 g max., Power Supply Module: 510 g max., Backplane: 445 g to 1040 g)
Note:
8
Be sure to disconnect the LG and GR terminals when conducting insulation resistance tests or dielectric strength tests. Internal components might be damaged if insulation resistance tests are
repeated many times with the LG and GR terminals connected.
CPU
YOUR INTRODUCTION TO THE C200HX/HG/HE CPU
Features
LED
Indicators
Select from Eleven C200Hα CPUs within Alpha’s
Three Basic Model Types
SYSMAC C200HX
Programmable Controller
CPU64
Each model has different program capacities, processing
speeds, I/O capabilities, communications connections and features. (The C200Hα CPU Selection Table is provided later in
this section.)
Memory cassette
DIP switch
Optional Back-up Memory Cassettes
Multifunctional
Peripheral port
For program back-up or rewrite option, each CPU has a special
Memory Cassette compartment.
Multifunctional Peripheral Port
Directly connect to programming peripherals or communicate to
Omron’s Operator Interface Terminals and other third party devices using an optional CIF Convertor Cable.
RS-232C port
Built-in RS-232C Port
Direct Host Link communications to the CPU or interface with
other devices through serial communications. Available on selected models only.
Versatile Communications
Install one of six C200Hα Communications Boards to have additional communications ports. The boards fit into the communications slot in the CPU and enable communication with SYSMAC
LINK or SYSMAC NET modules, a PC card module or a variety
of serial devices -- including Operator Interfaces. Order the
Communications Board and Memory Cassette separately (not
provided with the CPU).
Communications Board (C200HW-COM06-E shown here)
Indicators
INDICATOR ON THE CPU
FUNCTION
RUN (green)
Lit when the PLC is operating normally.
ERR (red)
Flashes if the PLC in operation detects any
non-fatal error. (The PLC will continue
operating.) Lit if the PLC in operation detects any
fatal error. (The PLC will stop operating. ) After
the PLC stops operating, the RUN indicator will
be off, and all output signals of the Output
Modules will be interrupted.
INH (orange)
Lit when the Load OFF flag (AR bit) is ON. (All
output signals of the Output Modules will be
interrupted.)
COMM (orange)
Flashes when the CPU is communicating with the
device connected to the peripheral port or
RS-232C port.
Protocol Macro
Three C200Hα Communications Boards offer the Protocol Macro Instruction that controls data transfer with various communications devices and components equipped with RS-232C or
RS-422/-485 ports. With the Protocol Macro Function built into
the C200HW-COM04, C200HW-COM05-E and C200HWCOM06-E Communications Boards, communications sequences (data transfer procedures) may be modified with Omron’s Protocol Support Software.
Although seven Omron Communications sequences are built-in,
you can use the Protocol Support Software to create other communications sequences. For more details, refer to the Communication Board section that follows.
9
CPU
C200HX/HG/HE CPU SELECTION GUIDE
Consider these Application Needs when Selecting the C200Hα CPU
1.
What is the required program capacity?
2.
Determine total standard I/O (with expansion rack) and Special I/O requirements.
3.
What communications interfaces are required?
C200Hα CPU Selection Table
PROGRAM
CAPACITY
(WORDS)
DM
(WORDS)
3.2K
4K
7.2K
6K
EM
(WORDS)
None
BASIC
INSTRUCTION
PROCESSING
TIME
0.3 µs min.
NO.
I/O
PTS.
640
MAX. NO.
EXPANSION
I/O RACKS)
2
880
MAX. NO. HIGHDENSITY
I/O MODULES
(GROUP 2)
MAX. NO. OF
SPECIAL I/O
MODULES
(GROUP 1)
NO. BELOW = TOTAL
NO. OF MODULES
NO. = TOTAL NO.
OF MODULES
Unavailable
10
RS-232C
CLOCK
FUNCTION
COMMUNICATIONS BOARD
AVAILABLE
PART NUMBER
No
No
No
C200HE-CPU11-E
Yes
Yes
C200HE-CPU32-E
Yes
Yes
10
Yes
15.2K
6K
6K
0.15 µs min.
880
1,184
31.2K
6K
6K x 3
(18K)
0.1 µs min.
880
1,184
Note:
10
2
3
2
3
10
10
No
C200HG-CPU43-E
C200HG-CPU53-E
16 (10)
See Note
No
10
10
No
16 (10)
S N
See
Note
t
C200HG-CPU33-E
Yes
16 (10)
See Note
16 (10)
S N
See
Note
t
C200HE-CPU42-E
Yes
C200HG-CPU63-E
Yes
Yes
C200HX-CPU34-E
Yes
C200HX-CPU44-E
No
C200HX-CPU54-E
Yes
C200HX-CPU64-E
When the table indicates a selection total of 16 High-density I/O Modules or Special I/O Modules -- the total of 16 is applicable only if you select from the Modules in
this list:
• High-density I/O Modules: C200H-ID216 (32 inputs) and C200H-OD218 (32 outputs).
• Special I/O Modules: C200H-AD002, C200H-DA002, C200H-NC211, and C200H-CT021
If your selections are not in the list above: you may be limited to only 10 modules -- as indicated in the table.
An exception: A total of only 8 can be used if you select C200H-OD219, C200H-ID217, or C200H-ID111 High-density I/O Modules.
CPU
SPECIFICATIONS, CHARACTERISTICS
C200Hα CPU Characteristics
ITEM
SPECIFICATIONS
Control method
Stored program
I/O control method
Cyclic scan with direct output and immediate interrupt processing are both possible.
Programming method
Ladder diagram
Instruction length
1 address/instruction, 1 to 4 words/instruction
Number of instructions
14 basic instructions, 231 special instructions
Execution time
Basic instructions:
e.g., LD
Special instructions:
e.g., MOV(21)
Program capacity
-E:0.3 µs
-E:0.15 µs
-E:0.1 µs
C200HE-CPU
C200HG-CPU
C200HX-CPU
-E:1.2 µs
-E:0.6 µs
-E:0.4 µs
C200HE-CPU
C200HG-CPU
C200HX-CPU
C200HE-CPU11-E: 3.2K words max.
C200HE-CPU32-E/CPU42-E: 7.2K words max.
C200HG-CPU
-E: 15.2K words max.
C200HX-CPU
-E: 31.2K words max.
I/O bits
640 (00000 to 02915, 30000 to 30915)
IR bits
6,464 (03000 to 23115, 31000 to 51115)
SR bits
1,080 (23200 to 25507, 25600 to 29915)
TR bits
8 (TR 0 to 7)
HR bits
1,600 (HR 0000 to 9915)
AR bits
448 (AR 0000 to 2715)
LR bits
1,024 (LR 0000 to 6315)
Timers/Counters
512 (TIM/CNT 000 to 511)
DM words
Read/Write: 6,144 (DM 0000 to 6143)
Read-only: 512 (DM 6144 to 6655)
Expansion: Up to 3,000 words max. (DM 7000 to 9999)
EM words
Read/Write:
C200HE-CPU
C200HG-CPU
C200HX-CPU
Power failure backup function
Holds HR, AR, CNT, DM, and EM and clock (RTC) contents.
Memory backup time
The battery service life is five years at 25°C (77°F). The service life will be shortened if the battery is used at higher temperatures.
Replace the battery within one week after the battery alarm indicator starts flashing. When replacing the battery, install the new
battery within five minutes after removing the old one.
Self-diagnostic function
CPU errors (watchdog timer), I/O verification errors, host link errors, memory errors, battery errors, I/O bus errors, remote I/O
errors, etc.
Program check function
Checks the program from the time the program starts running and checks the omission of the END instruction or any other improper instruction. This function allows three-level checking of programs through the Programming Console.
-E: None
-E: 6,144 (EM 0000 to EM 6143)
-E: 6,144 3 banks (EM 0000 to EM 6143)
11
CPU
SPECIFICATIONS, CHARACTERISTICS
Comparing C200Hα CPU Specifications
Use the following table to compare the functions of the C200HX, C200HG, and C200HE with those of the C200HS and C200H.
FUNCTION
C200HX/HG/HE
C200HS
C200H
User Memory (UM)
3.2K words (C200HE-CPU11-E)
7.2K words (C200HE-CPU 2-E)
15.2K words (C200HG-CPU 3-E)
31.2K words (C200HX-CPU 4-E)
15.2K words
3.2K words/7.2K words
Normal Data Memory (DM)
C200HX/G: 6,144 words (DM 0000 to DM 6143)
(DM 4000 to DM 5999 do not exist in the C200HECPU11-E) C200HE-CPU16: 4000 words (DM0000-3999)
6,144 words (DM 0000 to
DM 6143)
1,000 words (DM 0000 to
DM 0999)
Fixed Data Memory
512 words (DM 6144 to DM 6655)
512 words (DM 6144 to
DM 6655)
1,000 words (DM 1000 to
DM 1999)
Fixed Expansion Data Memory
0 to 3,000 words (DM 7000 to DM 9999)
0 to 3,000 words
(DM 7000 to DM 9999)
None
Extended Data Memory (EM)
C200HE:
C200HG:
C200HX:
None
None
Expansion Racks
3 max. (2 max. for C200HE-CPU
CPU-3 -E/4 -E)
2 max.
2 max.
Group-2 High-density I/O Modules
0 to 9 and A to F Modules per PLC
C200HE-CPU11-E: No Group-2 Modules connected
C200HE-CPU 2-E, C200HG/HX-CPU-3 -E/CPU4 -E:
0 to 9 Units per PLC
0 to 9 Modules per PLC
0 to 9 Modules per PLC
Special I/O Modules
0 to 9 and A to F Modules per PLC
C200HE-CPU
-E, C200HG/HX-CPU-3 -E/CPU4 -E: 0
to 9 Modules per PLC
0 to 9 Modules per PLC
0 to 9 Modules per PLC
Basic instructions (LD)
0.1 µs (C200HX)
0.15 µs (C200HG)
0.3 µs (C200HE)
0.375 µs
0.75 µs
Special instructions (MOV)
0.4 µs (C200HX)
0.6 µs (C200HG)
1.2 µs (C200HE)
19 µs
88 µs
Other special instructions
C200HX and C200HG: Approx. 1/3 to 2/3 of the time
required by the C200HS.
C200HE: Approx. 3/4 to 4/5 of the time required by the
C200HS.
---
---
END processing time
0.7 ms (C200HX/HE-CPU 2-E)
2.1 ms (C200HE-CPU11-E)
0.7 ms
2.8 to 3.5 ms
RS-232C port
C200HX/HG/HE-CPU2 -E/4 -E/6 -E
C200HS-CPU2 -E/3 -E
None
Clock function
All models except the C200HE-CPU11-E.
All models
Incorporated by the
Memory Module
SYSMAC LINK Module and
SYSMAC NET Link Module
connection
C200HW-COM01 and C200HW-COM04-E Communications
Boards available for connection except the C200HECPU11-E.
C200HS-CPU3 -E
C200H-CPU11-E/31-E
Communications Board
The Communications Board can be mounted to all CPUs
except the C200HE-CPU11-E. The following are possible
with the Communications Board:
Use of the SYSMAC LINK Module and SYSMAC NET Link
Module expansion of up to 2 communications ports, and use
of a protocol macro function
None
None
Interrupts
Interrupt Input Modules
2 (16 points)
1 (8 points)
None
Interruption with Communications Board
Possible
---
---
Response time
Same as the C200HS.
1 ms if the C200HW-SLK
C200H-compatible mode:
10 ms
C200H mode: 1 ms
The C200HS in any mode
connected to the SYSMAC LINK Module or
SYSMAC NET Link
Module 10 ms
---
Service time
3.5 ms max. (1 system)
10.8 ms max. (1 system)
11.5 ms max. (1 system)
Remote programming
Via the peripheral port, RS-232C port, and Communications
Board
Via the peripheral port
only
---
Influence on interrupt response
performance
None
10 ms is required by the
C200HS in any mode.
---
Memory
I/O
Execution
time
CPU
SYSMAC
LINK
12
No EM
6,144 words x 1 bank
6,144 words x 3 banks
-E and C200HG/HX-
is used.
CPU
SPECIFICATIONS, CHARACTERISTICS
User Memory Area
The C200HX, C200HG, and C200HE have a User Memory (UM) area allocation function. This function allows the use of the ladder program area of the UM as a fixed expansion DM area and I/O comment area. The function is enabled with the SYSMAC Support Software
(SSS), SYSWIN, or the Programming Console. Only SSS can be used to designate any part of the ladder program area as an I/O comment area (i.e., the Programming Console cannot be used to designate any part of the ladder program area as an I/O comment area.
Error
log
area
PLC
Setup
area
System
reserved
area
DM 9999
DM 7000
DM 6655
Fixed DM (512
words)
Normal Data Memory (DM) 6,144 words
Special I/O
Module
default area
DM 6600
DM 6144
DM 6000
DM 2599
DM 1000
DM 0000
C200HX/HG/HE Memory Area Structure
Fixed
expansion
DM area
(0 to 3,000
words)
I/O
comment
area
Ladder program area
Possible ROM area
Built-in UM (32K words max.)
Ladder program
area
A user program is stored in the ladder program area. If part of the UM is used as a fixed expansion DM area or I/O comment area, the capacity
of the ladder program area storing the user program will be reduced accordingly.
I/O comment area
I/O comments are stored in the I/O comment area. The I/O comments can be stored with a program. The I/O comments can be monitored
without loading the comment, just as with conventional comments.
Fixed expansion DM
area
The default values of the Special I/O Module, Programmable Terminal, the character string of the Programmable Terminal, and operation data
are stored in the fixed expansion DM area. By changing the I/O monitor present value of the Programming Console or using the DM edit transfer
operation of the Ladder Support Software, the default values can be written to DM 7000 to DM 9999.
System reserved
area
The system reserved area is used by the system only.
PLC Setup area
The settings required for the operation of the PLC are stored in the PLC Setup area.
Normal DM area
The user can freely use the normal DM as a data area for arithmetic operations. If the Special I/O Module is used, DM 1000 to DM 2599 will be a
Special I/O Module default area.
•
DM 1000 to DM 2599 can be used as a normal DM if DM 7000 to DM 8599 are set as a Special I/O Module default area with the PLC Setup. DM 6000 to DM 6030 are used
exclusively as an error log area.
•
Unlike the normal DM area, nothing can be written to the fixed expansion DM area using ladder programming.
•
The capacity of a ladder program will decrease if the size of the fixed expansion DM area and the total capacity of the I/O comments increase.
•
The C200HX, C200HG, and C200HE do not have a fixed expansion DM area or I/O comment area before shipping. The user must allocate these areas in the UM according to
the application.
13
COMMUNICATIONS BOARDS
SPECIFICATIONS, SELECTION GUIDE
Indicators
Indicators
Bus
connector
The C200Hα offers the industry’s most versatile PLC communications options. With six Communications Board options, you
can select just the right communications for your application.
The boards fit into the communications slot in the CPU and let
you expand the PLC functionality by connecting to other PLCs
or computers with Omron’s SYSMAC LINK, SYSMAC NET or, a
PC Card Module. A variety of serial ports let you connect to
Operator Interfaces, PCs, or other serial communication devices.
Port A
(RS-232C)
C200HW-COM01
C200HW-COM02
Specifications
Indicators
Indicators
Bus
connector
Port A
(RS-422/485)
C200HW-COM03
Port A
(RS-232C)
PART NUMBER
DESCRIPTION
C200HW-COM01
CPU connection when using SYSMAC LINK or
SYSMAC NET Link Communications Modules
C200HW-COM02
One RS-232C port
C200HW-COM03
One RS-422/485 port
C200HW-COM04-E
CPU connection for the SYSMAC LINK Module or
SYSMAC NET Link Module, and an RS-232C
port, with a protocol macro function
C200HW-COM05-E
Two RS-232C ports with a protocol macro
function
C200HW-COM06-E
One RS-422/485 port, and one RS-232C port,
with a protocol macro function
C200HW-COM04-E
Communications Board Indicators
Indicators
INDICATOR
COLOR
STATUS
MEANING
FUNCTION
RDY
Green
Not lit
Board not
ready for
use
Hardware error
Flashes
Setting error
System setting or
protocol data error
Lit
Board ready
for use
Normal operation
Flashes
Communicating
Port B is in use for
communication
Indicators
Port B
(RS-232C)
Port B
(RS-232C)
Port A
(RS-232C)
Port A
(RS-422/485)
COMB
C200HW-COM05-E
Note:
C200HW-COM06-E
Order the Communications Board and Memory
Cassette separately (not provided with the CPU).
Memory
Cassette
CPU
Communications
Board
14
COMA
Orange
Port A is in use for
communication
COMMUNICATION BOARDS
PROTOCOL MACRO
The Protocol Macro instruction permits easy interfacing of C200Hα
CPUs with peripheral devices. In cases where ASCII/BASIC Modules have been used to interface with peripheral devices, the Protocol Macro instruction now offers an extremely automated method.
The Protocol Macro instruction is a communications protocol that
controls data transfer using various devices and components
equipped with RS-232C or RS-422/485 ports -- thus, replacing
ASCII/BASIC Modules and the difficult associated programming
procedures. The C200Hα Communications Boards COM04-E,
COM05-E, and COM06-E have a built-in Protocol Macro capability,
providing seven Omron communications protocols. The data transfer procedures may be modified with Omron’s Protocol Support
Software. Communications sequences are executed from the ladder program with the Protocol Macro Instruction (PMCR).
IBM PC/AT or
Compatible
C200HW-ZW3AT1-E
Protocol Support Software:
The Protocol Macro software
is used to set or customize
protocol macro data.
Features
The C200Hα Communications Boards COM04-E, COM05-E, and
COM06-E (with protocol macro capability built-in) offer these seven
standard communications sequences:
1. Temperature Controller Sequence E5 J, E5 K, ES100 ,
and E5ZE
2. Intelligent Signal Processor Sequence K3TH, K3TR, K3TX,
and K3TC
3. Bar Code Reader Sequence V500 and V520
4. Laser Micrometer Sequence 3Z4L
5. Visual Inspection System Sequence F200, F300, and F350
6. ID Controller Sequence V600
7. Hayes AT Command (Modem) Sequence ME 1414BZ,
MD 24FB10V, and MD 144FB5V
Or, use the Protocol Support Software to create Communications
sequences other than those listed.
Standard measuring devices,
components, and personal
computers
C200HX/HG/HE
C200HW-COM04-E/05-E/06-E Communications Board
(with protocol macro function)
RS-232C
Asynchronous (start-stop synchronization) communication
OMRON’s peripheral devices (equipped with standard communications sequences)
Visual Inspection
System
Intelligent Signal
Processor
Modem
ID Controller
Temperature
Controller
Bar code
reader
15
COMMUNICATION BOARDS
PROTOCOL MACRO
System Configuration Examples
C200HX/HG/HE
RS-232C (C200HW-COM05-E)
An RS-232C line connects the C200HW-COM05-E and a
device, allowing the RS-232C line to be a maximum of 15 m.
15 m
RS-232C
port B
RS-232C
RS-232C
port A
RS-422/485 (C200HW-COM06-E)
The C200HW-COM06-E connects to one or more devices
through the RS-422 and RS-485 port provided the RS-422 or
RS-485 line between the C200HW-COM06-E and the farthest
device is a maximum of 500 m.
C200HX/HG/HE
15 m
RS-422/485 port A
RS-232C port B
RS-422/485
Temperature Controller
Temperature Controller
(With an RS-422 and RS-485
communications function)
Temperature Controller
Temperature Controller
Temperature Controller
500 m
16
Simple
communications
sequence
Device with
RS-232C
interface
MEMORY CASSETTES
SPECIFICATIONS
EEPROM or EPROM
Memory Cassettes
Each C200Hα CPU can accept a Memory Cassette to provide
back-up or downloading of programs and data. EEPROM models allow the program to be downloaded to and from the CPU
memory. EPROM models allow the user to write to an EPROM
and insert it into the memory cassette.
EEPROM Memory Cassette -No Back-up Power Supply Required
The EEPROM Memory Cassette can be installed in the
C200HX, C200HG, and C200HE CPUs to write and read programs and I/O data to the CPU.
Because the EEPROM Memory Cassette does not require any
backup power supply, it will retain its data even after it is disconnected from the CPU.
EEPROM
Memory Cassette
EEPROM Memory Cassette Capacity
CAPACITY
PART NUMBER
4K words
C200HW-ME04K
8K words
C200HW-ME08K
16K words
C200HW-ME16K
32K words
C200HW-ME32K
EPROM Memory Cassette -Use a Standard PROM Writer to Write a Program
Connect an EPROM to the EPROM Memory Cassette before
installing the EPROM Memory Cassette into the CPU.
An EPROM Memory Cassette will lose its data if it is disconnected from the CPU.
EPROM Memory Cassette Capacity
DESCRIPTION
CAPACITY
PART NUMBER
Cassette
16K words/32K words
C200HS-MP16K
EPROM (Order
ROM Separately)
S
t l )
Equivalent to 27256
ROM-JD-B
Equivalent to 27512
ROM-KD-B
EPROM
Memory Cassette
17
POWER SUPPLY MODULES
CAPACITIES AND SPECIFICATIONS
All CPU Racks and Expansion Racks feature
separate Power Supplies that may be replaced individually to meet system requirements without having to replace the other
components. The Power Supply provides
power for the CPU and Modules on the Rack.
Choose an AC or DC version. Model
C200HW-PA204S comes with built-in 24 VDC
Power Supply that may be used to power
Special I/O Modules, Sensors, or other devices, eliminating the need for a separate
Power Supply.
C200HW-P
18
Power Supply Modules Available
SUPPLY VOLTAGE
COMMENTS
PART NUMBER
100 to 120 VAC
200 tto 240 VAC
---
C200HW-PA204
With 24-VDC service
power supply
C200HW-PA204S
24 VDC
---
C200HW-PD024
BACKPLANES
SPECIFICATIONS
Select the Appropriate Backplane for the CPU
with its I/O Modules
When selecting Backplanes for the CPU, the Expansion I/O,
and the Slave Rack(s), each type of Backplane is a different
model number. To order, refer to the specific information provided separately in the Standard Parts section of this catalog.
Dimensions
CPU I/O Backplane
C200HW-BC
Unit: mm (inch)
130 118
(5.12) (4.65)
130
(5.12)
W1
W2
118
(4.65)
NO. OF SLOTS
W1
W2
PART NUMBER
3 slots
246 (9.69)
260 (10.24)
C200HW-BC031
5 slots
316 (12.44)
330 (12.99)
C200HW-BC051
8 slots
421 (16.57)
435 (17.13)
C200HW-BC081
10 slots
491 (19.33)
505 (19.88)
C200HW-BC101
Expansion I/O Backplane
C200HW-BI
Unit: mm (inch)
118
(4.65)
130
(5.12)
130
(5.12)
W1
W2
118
(4.65)
NO. OF SLOTS
W1
W2
PART NUMBER
3 slots
175 (6.89)
189 (7.44)
C200HW-BI031
5 slots
245 (9.65)
259 (10.20)
C200HW-BI051
8 slots
350 (13.78)
364 (14.33)
C200HW-BI081
10 slots
420 (16.54)
434 (17.09)
C200HW-BI101
19
BACKPLANES
SPECIFICATIONS
Slave Rack Backplane
C200H-BC
-V2
Unit: mm (inch)
130 118
(5.12) (4.65)
130
(5.12)
W1
W2
20
118
(4.65)
NO. OF SLOTS
W1
W2
PART NUMBER
3 slots
246 (9.69)
260 (10.24)
C200H-BC031-V2
5 slots
316 (12.44)
330 (12.99)
C200H-BC051-V2
8 slots
421 (16.57)
435 (17.13)
C200H-BC081-V2
10 slots
491 (19.33)
505 (19.88)
C200H-BC101-V2
CONNECTING I/O CABLES
FEATURES, CAPACITIES AND SPECIFICATIONS
I/O Connecting Cables connect a CPU Rack to an Expansion
I/O Rack or an Expansion I/O Rack to another Expansion I/O
Rack. The following five types of I/O Connecting Cables are
available. The total length of the I/O Connecting Cables used in
a configuration must be 12 m maximum.
Note:
Count the Expansion I/O Racks (connected in this way) against the
maximum of five Slave Racks that can be connected.
I/O Connecting Cables
Select from Five I/O Connecting Cables
CABLE LENGTH (CM)
PART NUMBER
30
C200H-CN311
70
C200H-CN711
200
C200H-CN221
500
C200H-CN521
1,000
C200H-CN131
Note:
The total length of the I/O Connecting Cables used in a network must not
exceed 12 m.
21
DISCRETE I/O MODULES
Connector
Style A
NK APP.
MADE IN JAPAN
NK APP.
MADE IN JAPAN
Connector
Style B
LOT
No. Corporation
OMRON
LOT
No. Corporation
02X2F
OMRON
C200H--OC222
OUTPUT
UNIT
LOT
No. Corporation
29XOF
OMRON
C200H--OA121--E
OUTPUT
UNIT
NK APP.
MADE IN JAPAN
OVERVIEW
Discrete I/O modules are available in a number of voltages,
densities, terminal block, and connector types. Connector-style
high-density I/O modules with 32 or 64 discrete I/O points per
module have solder connectors included with the module. Optional wiring methods are available using Omron’s I/O blocks,
screw terminal, crimp and ribbon connectors, and pre-terminated cables. These versatile high-density configuration options
minimize rack space and wiring time. The Omron I/O Blocks
provide single-point isolation and up to 5 A current capacity per
point. Replaceable relays and solid-state plug-in modules allow
easy maintenance. There are five styles of discrete I/O modules
in the C200H family. The profiles of each are shown here. Each
module in the following pages is cross-referenced to the module
style. Modules include the appropriate connectors.
Connector
Style C
Features
• Versatile high-density configuration options minimize rack
space and wiring time
LOT
No. Corporation
OMRON
NK APP.
MADE IN JAPAN
• Replaceable relays and solid-state plug-in modules mean
easy maintenance
Connector
Style D
Connector
Style E
Discrete I/O Modules -- Varying Connector Types
22
DISCRETE I/O MODULES
INPUT MODULE SPECIFICATIONS
Input Module Specifications
TYPE
AC Input
DC Input
AC/DC
Input
Note:
NO. OF
INPUTS
INPUTS PER
COMMON
INPUT VOLTAGE
INPUT
CURRENT
OPERATING
VOLTAGE
INPUT RESPONSE TIME
ON
OFF
ON
OFF
8 pts
8 pts.
100 to 120 VAC
+10%/--15%
10 mA,
100 VAC
60 VAC
min
min.
20 VAC
max
max.
35 ms
max
max.
55 ms
max
max.
16 pts.
16 pts.
8 pts.
8 pts.
16 pts.
16 pts.
200 to 240 VAC
+10%/--15%
10%/ 15%
10 mA,
200 VAC
120 VAC
min.
i
40 VAC
max.
8 pts.
8 pts.
12 to 24 VDC
+10%/--15%
10 mA,
24 VDC
10.2
VDC
min.
3.0 VDC
max.
16 pts.
16 pts.
24 VDC
+10%/--15%
7 mA,
24 VDC
14.4
VDC
min.
5.0 VDC
max.
8 pts.
8 pts.
12 to 24 VAC/DC
+10%/--15%
10 mA,
24 VDC
10.2
VDC
min.
3.0 VDC
max.
16 pts.
16 pts.
24 VAC/DC
+10%/--15%
7 mA,
24 VAC/
DC
14.4
VDC
min.
5.0 VDC
max.
MODULE-
PART NUMBER
STYLE
1.5 ms
max.
15 ms
max.
1.5 ms
max.
15 ms
max.
A
C200H-IA121
B
C200H-IA122
A
C200H-IA221
B
C200H-IA222
A
C200H-ID211
B
C200H-ID212
A
C200H-IM211
B
C200H-IM212
1. All models feature photocoupler isolation and LED indicator.
2. Each Discrete I/O Module has a removable terminal block. See the above STYLE column for a reference to the module style/connector type and refer to the accompanying drawing and chart for specific connector details.
Input Module Circuit Configuration
AC Input: IA121, IA122, IA221, IA222
C
R1
COM
IA121, IA122:
IA221:
IA222:
910Ω
R1
330 kΩ
680 kΩ
680 kΩ
C
0.33 µF
0.15 µF
0.15 µF
R2
470 Ω
820 Ω
680 Ω
V (AC)
100 to 120
200 to 240
200 to 240
IN
R
18 kΩ
+
+
COM
0.01 µF
R
ID211: 2 kΩ
ID212: 3 kΩ
Internal circuits
~
R2
Internal circuits
IN
DC Input: ID211, ID212
V (DC)
12 to 24
24
AC/DC Input: IM211, IM212
+
+
R
18 kΩ
~
COM
0.01 µF
IM211:
IM212:
R
2 kΩ
3 kΩ
Internal circuits
IN
V
12 to 24 VAC/DC
24 VAC/DC
23
DISCRETE I/O MODULES
OUTPUT MODULE SPECIFICATIONS
Output Module Specifications
No. of
outputs
Rated load
voltage
Max. load
current
Min.
switching
capacity
Output
response
times
ON
OFF
10
ms
max.
10
ms
max.
Leakage
current
Outputs/
per common
Fuse
External
power
supply
Internal power
consumption
(VDC)
---
8 pts.
---
---
10 mA max.
Relay Output
8 pts.
12 pts.
250 VAC
(cos φ = 1)/
250 VAC
(
(cos
0 4)/
φ = 0.4)/
24 VDC max.
Relay Output
2 A/pt.
8 A/8 pts.
10 mA,
5 VDC
C200H-OC221
2 A/pt.
8 A/ 12 pts.
12 pts.
C200H-OC222
(see note)
16 pts.
2 A/pt.
8 A/ 16 pts.
16 pts.
50 mA max.
C200H-OC225
(see note)
5 pts.
2 A/pt.
10 A/5 pts.
1 pt.
10 mA max.
C200H-OC223
8 pts.
2 A pts.
16 A/8 pts.
C200H-OC224
Triac Output
Triac Output
8 pts.
120 VAC
1 A/pt.
4 A/8 pts.
12 pts.
250 VAC,
50/60 Hz
0.3 A/pt.
2 A/12 pts.
Resistive
load:
A
10 mA;
inductive
load: 40 mA
(10 VAC)
1 ms
max.
1 ms
max.
8 pts.
1.2 A/pt.
4 A/8 pts.
Resistive
load:
100 mA;
inductive
load: 50 mA
(10 VAC)
12 pts.
0.5 A/pt.
2 A/12 pts.
100 mA,
10 VAC;
50 mA,
24 VAC;
100 mA,
100 VAC
1/2 of
load
frequency
max.
1/2 of
load
f
frequency
max.
1/2 +
1 ms
of
load
frequency
max.
3 mA max.,
VAC;
100 VAC
A max.,
6 mA
200 VAC
1.5 mA
max.,
120 VAC;
3 mA max.,
240 VAC
8 pts.
5A
140 mA max.
C200H-OA121-E
12 pts.
3A
200 mA max.
C200H-OA222V
8 pts.
5A
180 mA max.
C200H-OA223
12 pts.
3.15 A
270 mA max.
C200H-OA224
Transistor Output
8 pts.
12 pts.
Transistor
Output
12 to 48 VDC
+10%/--15%
1 A/pt.
3 A/8 pts.
24 VDC
+10%/--15%
2.1 A/pt.
5.2 A/8 pts.
0.2
ms
max.
0.3
ms
max.
0.1 mA
max.
Residual
voltage:
1.5 V max.
1 ms
max.
1 ms
max.
1 mA max.
5 to 24 VDC
0.3 A/pt.
10 mA,
5 VDC
1.5
ms
max.
2 ms
max.
0.1 mA
max.
24 VDC
+10%/--15%
0.3 A/pt.
2A/12 pts.
Residual
voltage:
1.4 V max.
0.2
ms
max.
0.3
ms
max.
0.3 A/pt.
4.8 A/12 pts
12 pts.
5 to 24 VDC
0.3 A/pt.
16 pts.
24 VDC
+10%/--15%
1 A/pt.
4 A/16 pts.
Note:
Residual
voltage:
1.4 V max.
0.8 A/pt.
2.4 A/8 pts.
16 pts.
24
Part number
10 mA,
5 VDC
1.5
ms
max.
2 ms
max.
8 pts.
5A
30 mA, 12
to 48 VDC
min.
140 mA max.
C200H-OD411
8A
30 mA, 24
VDC min.
C200H-OD213
None
150 mA, 24
VDC min.
C200H-OD214
5 to
24 VDC
10 mA max.
C200H-OD216
12 pts.
5A
25 mA, 24
VDC min.
160 mA max.
C200H-OD211
16 pts.
8A
35 mA, 24
VDC min.
180 mA max.
C200H-OD212
12 pts.
None
5 to
24 VDC
10 mA max.
C200H-OD217
160 mA max.
C200H-OD21A
Residual
0.1
0.3
16 pts.
35 mA, 24
voltage:
ms
ms
VDC min.
0.8 V max.
max.
max.
Do not exceed the load current of 8 A per common. No more than 8 outputs can be turned ON simultaneously.
DISCRETE I/O MODULES
OUTPUT MODULE SPECIFICATIONS
Output Module Circuit Configuration
Relay Output:
OC221, OC222, OC223, OC224, OC225
Triac Output: OA222V, OA121-E
OUT
Internal circuits
L
+
X
L
Internal circuits
OUT
+
COM
Fuse blowout
detector
COM
OA222V: no fuse blowout detector
Use either + or -- VDC
Triac Output: OA223, OA224
OUT
L
Transistor Output: OD411/OD211
+V
Output indicator
LED
Internal circuits
COM
Fuse
Internal circuits
L
250 VAC max.
Fuse blowout
detector
L
+
COM
Fuse
Fuse blowout
detector
“F”
LED
“F”
LED
OUT
OD211: no fuse blowout detector
OA224: no fuse blowout detector
Transistor Output: OD213/OD212
Transistor Output (Source Type): OD214
+V
Output
LED
Output indicator
OUT
Internal circuits
“F”
LED
Internal circuits
LED
L
+
Fuse
COM
Fuse blowout
detector
indicator
+V
OUT
Source
driver
L
+
+ 24 VDC
COM
Reset switch
Alarm output LED
OD212: No fuse blowout detector
Transistor Output (Protective Circuit for Load
Short-circuit): OD216/OD217
Output
indicator LED
+V
OUT
RESET
L
+
COM
5 to
24 VDC
Internal circuits
Internal circuits
Note:
Transistor Output (Source Type with Protective
Circuit for Load Short-circuit): OD21A
+
LED
24 VDC
OUT00
L
OUT15
L
COM
ALARM
Fuse blowout detection circuit: The F indicator is lit and the 08 bit turns ON. The 08 to 15 bits cannot be used as ordinary IR bits.
25
SPECIAL I/O MODULES
B7A INTERFACE MODULES
The C200H-B7A Interface Modules reduce wiring from 16 input
devices or 16 output devices to a few wires. The B7A allows
you to remotely connect I/O that would have required direct connection to the PLC. You save control panel space, wiring time,
and man-hours required for installation. These modules can be
used with the full range of B7A input and output blocks for 16
I/O. The modules require a power supply, as do the terminal
blocks.
C200H-B7Al1
(16 Input Points)
Features
• Connect directly to the B7A I/O blocks using a two-conductor
wire
C200H-B7AO1
(16 Output Points)
• Transmission distance up to 500 m max.
C200H-B7A12
(32 Input Points)
C200H-B7A21
(16 Input and
16 Output Points)
26
C200H-B7A02
(32 Output Points)
C200H-B7A22
(32 Input and
32 Output Points)
SPECIAL I/O MODULES
B7A INTERFACE MODULES
System Configuration
B7A input 32 pts./output 32 pts.
B7A input 16 pts./output 16 pts.
B7A output 32 pts.
B7A input 32 pts.
C200HX/HG/HE
B7A Link Terminals
Input
Note:
Input
Output
Output
Input
Output
Input
Input
Output
Output
Refer to the B7A Link Terminals Datasheet
(Q101) for more details.
27
SPECIAL I/O MODULES
B7A INTERFACE MODULE
Performance Specifications
PART NUMBER
C200H-B7AI1
C200H-B7AO1
C200H-B7A12
B7A INTERFACE MODULES
C200H-B7A02
C200H-B7A22
16 output points and
16 input points or
15 input points + 1
error input
32 output points and
32 input points or
30 input points + 2
error inputs
I/O points
16 points or 15
points and 1 error
input
Transmission distance
500 m max. if power is supplied to the
Interface Module and B7A Link Terminal
separately.
Standard:
500 m max. using separate power supplies.
100 m max. using a common power supply.
100 m max. if power is supplied to the
Interface Module and B7A Link Terminal
from a single power supply.
High-speed:
100 m max. using separate power supplies.
50 m max. using a common power supply.
If shielded cable is not used, the maximum transmission distance is 10 m regardless of
whether a common or separate power supplies are used.
19.2 ms typical, 31 ms max.
Standard:
19.2 ms typical, 31 ms max.
High-speed:
3 ms typical, 5 ms max. (see note 1)
0.05 A min.
0.06 A min.
Transmission delay
16 output points
32 input points or
30 input points and 2
error inputs
32 output points
Internal current
consumption
5 VDC, 100 mA max.
External power
ower supply
su ly
(
(see
note
t 2)
12 to 24 VDC ±10%
Weight
200 g max.
300 g max.
Word allocations
Same as I/O Modules (in order mounted).
The words allocated to Group-2 B7A Interface Modules are determined by I/O number set on
the Modules. Words 030 to 049 allocated according to I/O number setting. Modules with 32
I/O points are allocated two words; Modules with 64 I/O points are allocated four words.
Note:
0.01 A min.
0.03 A min.
1. The transmission delay is changed by using the DIP switch.
2. The value of the external power supply does not include the value required by the B7A Link Terminal.
Connectable B7A Link Terminals
Input Terminals
TYPE
TRANSMISSION DELAY
PART NUMBER
Screw terminals
Standard (19.2 ms)
B7A-T6 1
B7A-T66
B7AS-T66
B7AS-T6 1
High-speed
High
s eed (3 ms)
Modular
Standard (19.2 ms)
B7A-T6D2
High-speed (3 ms)
B7A-T6D7
Standard (19.2 ms)
B7A-T E3
High-speed (3 ms)
B7A-T E8
TYPE
TRANSMISSION DELAY
PART NUMBER
Screw terminals
Standard (19.2 ms)
B7A-R6
PLC connectors
Output Terminals
1
1
B7A-R66
B7AS-R66
B7AS-R6
High-speed
High
s eed (3 ms)
Modular
PLC connectors
28
C200H-B7A21
GROUP-2 B7A INTERFACE MODULES
Standard (19.2 ms)
B7A-R6A52
High-speed (3 ms)
B7A-R6A57
Standard (19.2 ms)
B7A-R A 3
High-speed (3 ms)
B7A-R A 8
0.05 A min.
0.08 A min.
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE SPECIFICATIONS (GROUP-2)
The High-density Input Modules let you pack more input points
into a single I/O slot for greater space savings. These modules
do not use standard I/O points. Thus, they increase the overall
I/O capacity. They provide 32 or 64 discrete input points. The
modules can be used with Omron’s Terminal Blocks, reducing
wiring between control panels, as well as within control panels.
Features
• Easy cable connection to Omron’s XW2B- Terminal
Blocks using XW2Z- Connecting Cable. Refer to the
Standard Parts section for detailed ordering information.
C200H-ID216
(32 DC input pts.)
C200H-ID217
(64 DC input pts.)
• Up to ten 64-point modules or 32-point modules per PLC
Note:
The ambient temperature affects the number of points that can
be ON simultaneously.
Specifications
PART NUMBER
C200H-ID216
C200H-ID217
Number of inputs
32 points
64 points
Rated input voltage
24 VDC +10%/--15%
Input current
4.1 mA typical at 24 VDC
Input impedance
5.6 kΩ
ON voltage
14.4 VDC min.
OFF voltage
5.0 VDC max.
Input ON delay
1.0 ms max.
Input OFF delay
1.0 ms max.
Isolation
Photocoupler
Input indicator
LED
External connections
Connector
Number of circuits (see
note)
32 points with one
common
64 points with two
commons
Internal power consumption
100 mA max. at
5 VDC
120 mA max. at 5
VDC
Weight
180 g max.
250 g max.
Manual
W302
Circuit Configuration
ID216
COM
680 Ω
5.6KΩ
to
A
CN1/CN2
IN15
Input indicator
B
Note:
1. The polarity of the input power supply source can be positive or negative provided that the
polarity of each common is the same.
2. Although each COM is internally connected, wire them all.
3. The mountable number of High-density I/O Modules varies with the CPU. No High-density
I/O Module can be mounted to the Slave Rack.
IN00
to
IN07
COM
IN08
to
IN15
COM
IN00
to
IN07
IN08
to
IN15
1000 PF
A
B
CN1
SW
CN2
Input indicator
A
ID111: 820 Ω
ID217: 680 Ω
B
2.7 kΩ
5.6 kΩ
29
Display switch
1000 PF
Internal circuits
A/B
IN00
to
IN07
COM
IN08
Internal circuits
ID217
COM
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE SPECIFICATIONS (GROUP-2)
Using the High-density Output Modules, you pack more output
points into a single I/O slot for greater space savings. These
modules increase the overall I/O capacity, while not using standard I/O points. They provide 32 or 64 discrete output points.
The modules can be used with Omron’s Terminal Blocks and
Cables, reducing wring between control panels, as well as within control panels.
Features
• Easy cable connection to Omron’s XW2B- Terminal Blocks
using XW2Z- Connecting Cable. Refer to the Standard
Parts section for detailed ordering information.
C200H-OD218
C200H-OD219
(32 DC output pts.)
(64 DC output pts.)
• Up to ten 64-point modules or 32-point modules per PLC
Specifications
PART NUMBER
C200H-OD218
C200H-OD219
Number of outputs
32 points
64 points
Max. switching capacity
16 mA at 4.5 V to 100 mA at 26.4 V
Leakage current
0.1 mA max.
Residual voltage
0.8 V max.
Input ON delay
0.1 ms max.
Input OFF delay
0.4 ms max.
Output indicator
LED
External connections
Connector
Number of circuits
32 points with one
common
Fuse (see note)
3.5 A (one/common)
External power supply
110 mA (3.4 mA per ON
pt) min. at 5 to 24 VDC
±10%
220 mA (3.4 mA per ON
pt) min. at 5 to 24 VDC
±10%
Internal power
consumption
180 mA max. at 5 VDC
260 mA max. at 5 VDC
Manual
W302
Note:
64 points with two
commons
The fuse is not user replaceable.
Circuit Configuration
OD218
OD219
OUT00
to
OUT07
Output indicator
COM
F indicator
Fuse
3.5A
OUT08
to
OUT15
COM
4.5 to 26.4 VDC
OUT00
to
OUT07
COM
4.5 to 26.4 VDC
OUT08
to
OUT15
COM
30
A
OUT00
to
OUT07
COM
4.5 to 26.4 VDC
Output indicator
Fuse
break
detec
tor
4.5 to 26.4 VDC
Internal circuits
Internal circuits
4.5 to 26.4 VDC
Fuse
CN1
SW
Display
switch/
fuse
break
detector
Output indicator
4.5 to 26.4 VDC
OUT08
to
OUT15
COM
CN2
F indicator
B
Note:
The number of Group-2 High-density Output Modules is limited by the CPU model.
They cannot be used with the Slave Rack.
CN1/
CN2
SPECIAL I/O MODULES
ANALOG TIMER MODULE
The Analog Timer Module lets the user fine-tune timer values
manually, without going into the PLC program. Adjustments can
be made from the front part of the module or from remote locations (using a special cable and external variable resistors).The
module has four independently set and monitored timers that
each have variable ranges. The user may select, by DIP switch,
for each point to use front panel variable resistor or external
variable resistors. Through internal bit allocation, each timer can
be started and paused, allowing for them to be used as cumulative timers.
Features
C200H-TM001
• Four front panel variable resistors are used to set the
timers
• Connecting Cable No. C4K-CN233 available for external
variable resistors
• Indicators show operation and time-up status
• Cumulative timer available using pause bits
• Timer values may be adjusted without program changes
System Configuration
Specifications
PART NUMBER
C200H-TM001
Timing method
CR oscillator
No. of timers
4
Setting ranges
0.1 to 1.0 s, 1 to 10 s, 10 to 60 s, 1 to 10 min
Operation
Controllable from PLC program. Usable as accumulating
timer.
External adjustment
Via C4K-CN223 (2 m) connector to 20-kΩ resistor
Manual
W302
C200HX/HG/HE
C4K-CN223
(2 m)
External adjustments
mounted as required by
application.
31
SPECIAL I/O MODULES
INTERRUPT INPUT MODULE
The Interrupt Input Module allows real world discrete inputs to
interrupt the scan of the main ladder logic program and execute
specific interrupt ladder logic. For systems requiring immediate
response and fast throughput from field input signals, the Interrupt Input Module can provide fast sub-scan execution and response times. The Module can be configured to provide immediate interrupts and scheduled interrupts which repeat
execution on a preset time base. Interrupts can also be configured to interrupt currently executing interrupt logic.
Features
C200HS-INT01
• Using input interrupts, the Interrupt Input Module
temporarily interrupts the main program to execute
interrupt subroutines
• High-speed immediate or scheduled logic execution
• Provides sub-scan response to field input signals
• Ladder instructions control and monitor interrupt inputs
Specifications
PART NUMBER
C200HS-INT01
Rated Input Voltage
12 to 24 VDC +10%/--15%
Input Impedance
2 KΩ
Input Current
10 mA typical (24 VDC)
ON Voltage
10.2 VDC min.
OFF Voltage
3.0 VDC max.
ON Response Time
0.2 ms max.
OFF Response Time
0.5 ms max.
No. of Circuits
1 (8 points/common)
Internal Current Consumption
20 mA, 5 VDC max.
Weight
200 g max.
Manual
W302
Note:
32
The Interrupt Input Module must be mounted on the CPU Rack. Only two
Interrupt Input Modules can be mounted per CPU Rack.
SPECIAL I/O MODULES
INTERRUPT INPUT MODULE
Interrupt Input Operation
The above application shows input bits IR 00400 through IR 00407
assigned to subroutines 00 to 07. For example, when the input for IR
00400 goes ON, normal program execution is interrupted and the
subroutine between SBN 000 and RET is executed. If required, outputs can be refreshed immediately by programming the I/O REFRESH instruction within the subroutine.
Normal
program
area
END(01)
SBN(92) 00
IORF(97)
Input
ON
003
003
IR 00400
SBN 000
IR 00401
SBN 001
IR 00402
SBN 002
Interrupt
subroutine
program
area
RET(93)
IR 00407
Note:
SBN 007
Only the word 003 output processed in the interrupt
subroutine program is immediately refreshed.
If the Interrupt Input Module is mounted on an Expansion I/O Rack,
the interrupt function cannot be used, and the Interrupt Input Module will be treated as an ordinary 8-point Input Module. Interrupt Input Modules cannot be used on Slave Racks.
Circuit Configuration
IN
IN
2 kΩ
COM
0.01
µF
1.8
kΩ
Internal
Circuit
12 to 24 VDC
Input indicator
The polarity of the input power supply source can be positive or
negative provided that the polarity of each common is the same.
33
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE
The High-density Input Modules let you pack more input points
into a single I/O slot for greater space savings. Functioning as
as Special I/O modules, they do not use standard I/O points.
Thus, they increase the overall I/O capacity. They provide 32
discrete input points with selectable response times of 2.5 ms or
15 ms. For even shorter signals, 8 inputs can be designated as
quick-response inputs, to receive selectable 1 ms or 4 ms signals. The modules can also be used with Omron’s Terminal
Blocks, reducing wiring between control panels as well as within
control panels.
C200H-ID215 (DC input)
C200H-ID501 (TTL input)
Features
• 8 quick-response inputs available to receive short signals
• Easy cable connection to Omron’s XW2B- Terminal Blocks
using XW2Z- Connecting Cable. Refer to the Standard
Parts section for detailed ordering information.
• Selectable input response time
• LED indicator
• Provides a photocoupler for isolation
Specifications
PART NUMBER
C200H-ID215
C200H-ID501
MODULE NAME
DC INPUT MODULE
TTL INPUT MODULE
No. of inputs
32
Input voltage and input current
24 VDC ±10%/--15%
4.1 mA, 24 VDC
5 VDC ±10%;
3.5 mA, 5 VDC
Operating voltages
ON: 14.4 VDC min.
OFF: 5.0 VDC max.
ON: 3.0 VDC min.
OFF: 1.0 VDC max.
Output response times
ON: 2.5/1.5 ms (selectable)
OFF: 2.5/15 ms (selectable)
Inputs per common
8 pts (4 circuits)
Internal current consumption
130 mA max. (5VDC)
Manual
W302
Note:
34
High-density Modules are equipped with quick-response functions and have
Special I/O functions. When mounting these models to a SYSMAC BUS
Slave, the Remote I/O Master must be the C200H-RM001-PV1 or C200HRM201.
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE
Circuit Configuration
TTL Input: ID501
DC Input: ID215
+
IN
5.6 kΩ
5 VDC
+
+
IN
2.4 kΩ
1.1 kΩ
Internal circuits
24 VDC 1000 pF
+
COM
Internal circuits
620 Ω
COM
Connect to either + or -- terminal on DC power supply.
I/O Refresh Instruction
The I/O Refresh instruction, IORF(97), can be used with
the quick-response input function to read the input status
held in the quick-response input buffer whenever needed
in a program.
00000
Machine Number Setting and Input Bit No.
When set to machine No.: n (0 to 9), words [100+10n+1]
can be used as input bits. Input bits 08 to 15 of word 1n1
can be used as quick-response
inputs.
IORF(97)
St
E
When 00000 is ON, all words from St
to E will be refreshed.
St and E would be 101 for Unit #0,
making bits IR 10108 to IR 10115
quick-response input bits.
Example: When set to 8,
input bits 18108 to 18115
become quick-response
inputs.
Machine No.
setting
switch
Quick-response Input Operation and Timing
With quick-response input function these High-density I/O
Modules can read short-pulse input signals, such as those from
photomicrosensors.
With standard I/O Modules, an input must be ON during the I/O
refresh period for it to be read into the PLC. Input signals
shorter than the cycle time can be missed, unless they happen
to occur during the I/O refresh.
The quick-response input buffer (on our High-density and
Mixed I/O Module) is used to hold input signals as short as
1 ms or 4 ms (selectable) allowing them to be read into the IR
area during the next I/O refresh. (Any pulse that is equal to or
longer than the minimum time setting affects the program during
the next program execution.)
The quick-response input function is available on input points
number 08 to 15 on CN2.
35
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE
The High-density Output Modules let you pack more output
points into a single I/O slot for greater space savings. Treated
as Special I/O modules, they do not use standard I/O points.
Thus, they increase the overall I/O capacity. In static high-density mode, they provide 32 discrete output points. In this mode,
the modules can also be used with Omron’s Terminal Blocks,
reducing wiring between control panels as well as within control
panels. In dynamic multiplex mode, the modules provide 128
dynamic output points. In this mode they can be used with numeric displays, etc.
Features
• Provide 32 outputs per module in static mode
C200H-OD215
(32 transistor output pts.)
C200H-OD501
(32 TTL output pts.)
• Easy cable connection to Omron’s XW2B- Terminal Blocks
using XW2Z- Connecting Cable. Refer to the Standard
Parts section for detailed ordering information.
• Provide interface to numeric displays, etc. in dynamic mode
Specifications
PART NUMBER
C200H-OD215
C200H-OD501
MODULE NAME
TRANSISTOR OUTPUT
TTL OUTPUT
No. of outputs
32
Rated load voltage
5 to 24 VDC +10%/--15%
5 VDC ±10%;
Max. load current
16 mA at 4.5 V to
100 mA at 26.4 V/pt.
800 mA/8 pts. 3.2 A/32
pts.
35 mA/pt. 280 mA/8 pts.
1.12 A/32 pts.
Outputs per common
8 pts
Output response times
ON: 0.2 ms max.
OFF: 0.6 ms max.
External connection
connector
Residual voltage
0.7 V max.
Leakage current
0.1 mA max
External power supply
90 mA, 5 to 24 VDC min.
Internal power consumption
220 mA max.
Manual
W302
Note:
36
ON: 0.2 ms max.
OFF: 0.3 ms max.
0.4 V max.
39 mA, 5 VDC min.
When mounting these models to a Slave Rack, the Remote I/I Master must
be the C200H-RM001-PV1 or C200H-RM201.
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE
Dynamic Output Mode for Digital Displays
With dynamic outputs, data signals DATA0 to DATA15 are
combined with strobe signals STB0 to STB15 to reduce
wiring and greatly increase output capacity. The output
device must be able to receive dynamic signals.
Circuit Configuration
Transistor Output: OD215/TTL Output: OD501
OUT
Internal circuits
Position Control Module
C200H-NC111/NC112
R3
L
+
Fuse
OD501:
OD215:
R1
4.7 kΩ
None
V
Common
V
5 VDC
5 to 24 VDC
C200HX/HG/HE
M7F
Servomotor
Servodriver
37
SPECIAL I/O MODULES
MIXED I/O MODULE
The high-density/multiplex mixed Input/Output modules let you
pack more I/O points into a single I/O slot for greater space savings. Treated as Special I/O modules, they do not use standard
I/O points. Thus, they increase the overall I/O capacity.
In static high-density mode, they provide 16 discrete input
points and 16 discrete output points with selectable input
response times of 2.5 ms or 15 ms. For even shorter input
signals, 8 inputs can be designated as quick-response inputs, to
receive selectable 1 ms or 4 ms signals. In this mode, the
modules can also be used with Omron’s Terminal Blocks,
reducing wiring between control panels as well as within control
panels.
C200H-MD215/MD115
(16 DC input/16 transistor output pts.)
C200H-MD501
(16 TTL input/16 TTL output pts.)
In dynamic multiplex input mode, the modules provide 128
dynamic input points. In this mode they can be used with
keyboards, thumbwheel switches, etc.
Features
• Provide 16 inputs and 16 outputs per module in static mode;
128 inputs in dynamic mode
• Easy cable connection to Omron’s XW2B- Terminal Blocks
using XW2Z- Connecting Cable. Refer to the Standard
Parts section for detailed ordering information.
• Selectable input response time
• Up to 10 Special I/O modules per PLC
• Provide interface to keyboards, thumbwheel switches, etc. in
dynamic mode
Specifications
MODULE NAME
TTL INPUT/OUTPUT MODULE
DC INPUT/TRANSISTOR OUTPUT MODULE
PART NUMBER
C200H-MD501
C200H-MD215
C200H-MD115
Inputs
No. of inputs
16 pts
Input voltage and current
5 VDC ±10%, 3.5 mA (5 VDC)
24 VDC +10%--15%, 4.1 mA
(24 VDC)
12 VDC +10%--15%, 4.1 mA typical
(12 VDC)
Operating voltages
ON: 3.0 V min., OFF: 1.0 V max.
ON: 14.4 V min., OFF: 5.0 V max.
ON: 8.0 V min., OFF: 3.0 V max.
Input response times
ON/OFF: 2.5 ms/15 ms (selectable)
Isolations
Photocoupler
Inputs per common
8 pts
No. of outputs
16 pts
Rated load voltage
5 VDC
5 to 24 VDC
12 VDC
Max. load current
35 mA/pt, 280 mA/8 pts
100 mA/pt, 800 mA/8 pts
100 mA/pt, 800 mA/8 pts
Residual voltage
0.4 V max.
0.7 V max.
Output response times
ON: 0.2 ms max., OFF: 0.3 ms max.
ON: 0.2 ms max., OFF: 0.6 ms max.
Leakage current
0.1 mA max.
Outputs per common
8 pts
Fuse
Present (replacement not possible)
Outputs
External connection
Connector
Internal current consumption (5 VDC)
180 mA max.
Manual
W302
Note:
38
When mounting any of the above models to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-RM201.
SPECIAL I/O MODULES
MIXED I/O MODULE
Circuit Configuration
MD501/MD215/MD115
Internal circuits
R1
L
+
V1
OUT
Fuse
R3
R2
C
COM
IN
+
+
V2
COM
Dynamic Input Mode Operation and Timing
With dynamic inputs, data signals DATA0 to DATA15 are combined with strobe signals STB0 to STB15 to reduce wiring and
greatly increase input capacity. For example, when STB0 is ON,
as shown to the right, data would be read from DATA0 to
DATA3, and the status of switches A through D would be reflected in bits 00 through 03 of word 1n0, where n is the Special
I/O Module’s unit number.
R1
R2
R3
C
V1
V2
MD501
4.7 kΩ
1.1 kΩ
2.4 kΩ
None
5 VDC
5 VDC
MD215
None
5.6 kΩ
620 Ω
1000 pF
5 to
24 VDC
24 VDC
MD115
None
2.7 kΩ
620 Ω
1000 pF
5 to
24 VDC
12 VDC
STB0
(CN1 A1)
D
C
B
A
DATA0 (CN2 A1)
DATA1 (CN2 A2)
DATA2 (CN2 A3)
DATA3 (CN2 A4)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Wd 1n0
Wd 1n1
Wd 1n2
to
Wd 1n7
D C B A
39
SPECIAL I/O MODULES
ANALOG INPUT MODULES
Analog Input Modules accept a variety of analog signals from
external devices, including both voltage and current ranges.
Both Modules provide 12-bit resolutions and fast access to the
PLC.
Features
• Cost-effective single-slot modules available with 4 or 8
analog inputs
C200H-AD001
• 12-bit resolution
C200H-AD002
• Selectable ranges include 1 to 5 V, 0 to 10 V, and 4 to 20 mA
Specifications
System Configuration
PART NUMBER
C200H-AD001
C200H-AD002
Input points
4
8
Voltage input
1 to 5V or 0 to 10 V
1 to 5 V, 0 to 10 V, or
--10 to 10 V
Current
input
4 to 20 mA
External
in
ut im
ed
input
impedance
Voltage
input
1 MΩ min.
Current
input
250 Ω
Resolution
Voltage
1/4,000 FS
Current
Total precision
C200HX/HG/HE
Flow
Temperature
Current
Transducer
Pressure
Analog input
Voltage
Analog signals, such as voltages and currents, are received
from various sensors through the maximum of 8 inputs
(AD002) and converted into 12-bit binary data.
External input signal range can be freely set to cope with
diverse needs.
Built-in functions included: the scaling function, mean function, peak hold function, square-root extraction function, and
more.
40
25°C
77.0°F
±0.5% FS
Voltage: ±0.25% FS
Current: ±0.4% FS
0° to
55°C
(32° to
131°F)
±1.0% FS
Voltage: ±0.6% FS
Current: ±0.8% FS
Conversion speed
2.5 ms max./pt
Converted data
12-bit binary
Maximum input
ut signals
Voltage
input
±15 V max.
Current
input
±30 mA max.
12-bit binary or 4-digit
BCD code (selectable)
I/O words required
10 (Special I/O area)
External connections
Terminal block
Connector
Current consumption
550 mA max., 5 VDC
450 mA max., 5 VDC
Weight
450 g max.
290 g max.
Manual
W127
W229
SPECIAL I/O MODULES
ANALOG OUTPUT MODULES
Analog Output Module provides an interface to a variety of external analog devices that accept voltage and current ranges,
including servo controllers, recorders, and analog gauges.
Features
• Cost-effective single-slot module offers two or four analog
outputs
• 12-bit resolution
• Selectable ranges include 1 to 5 V, 0 to 10 V, -10 to +10 V,
and 4 to 20 mA
C200H-DA001
Specifications
C200H-DA002
PART NUMBER
C200H-DA001
C200H-DA002
Output points
2
4
Voltage output
1 to 5V or 0 to 10 V
--10 to 10 V
Resolution
Total precision
Current
output
4 to 20 mA
Voltage
1/4,095 FS
Current
1/4,095 FS
25°C
77.0°F
±0.5% FS
Voltage: ±0.3% FS
Current: ±0.5% FS
0° to
55°C
(32° to
131°F)
±1.0% FS
Voltage: ±0.5% FS
Current: ±1.0% FS
1/8,190 FS
Conversion speed
2.5 ms max./pt
External output impedance
0.5 Ω min.
Maximum
external output current
Voltage
output
15 mA
Current
output
---
Voltage
output
---
Current
output
400 Ω
350 Ω
12-bit binary
Voltage code bit + 12-bit
binary
Current code bit + 12-bit
binary
Allowable
load resistance of external output
System Configuration
C200HX/HG/HE
10 mA
Analog output
Servomotor driver
Inverter
Converted data
I/O words required
10 (Special I/O area)
External connections
Terminal block
Connector
Current consumption
650 mA max., 5 VDC
600 mA max., 5 VDC
Weight
450 g max.
320 g max.
Manual
W127
W260
M
Recorder
Converts 12-bit binary data into analog signals (voltage or current) for
output to external devices.
Output signal range can be freely set to cope with diverse needs.
Built-in functions such as the output limit, upper- and lower-limit
alarm, and pulse output functions make the C200HX/HG/HE even
more powerful.
41
SPECIAL I/O MODULES
TEMPERATURE SENSOR MODULES
Monitor up to 4 temperature sensor inputs directly from the PLC
rack. Choose thermocouple inputs (types J and K), or platinum
RTD inputs. Each module offers multiple ranges and a choice of
Fahrenheit or Celsius scaling.
Features
• Available for thermocouple types J and K, or platinum RTD
temperature sensors
• Selectable number of inputs
• Wide range of temperature settings
C200H-TS001
C200H-TS101
Specifications
PART NUMBER
C200H-TS001
C200H-TS101
TYPE
THERMOCOUPLE
PLATINUM
RESISTANCE
THERMOMETER
Temperature
sensor
Thermocouples: K (CA),
J (IC) (selectable)
RTD
(JPt 100 Ω)
Input points
4 points/Unit max. (1, 2, or 4 points can be selected)
Converted data
±(1% FS + 1°C) max.
Total precision
4.8 s max. when 4 points/Unit is set
2.4 s max. when 2 points/Unit is set
1.2 s max. when 1 points/Unit is set
PLC fetch time
Conversion cycle + PLC1 cycle time (5 s max.)
Insulation
Between points: Uninsulated
Between input terminal and PLC signal: Insulated with a
photocoupler
42
I/O words required
10 (Special I/O area)
Current
consumption
450 mA max., 5 VDC
Weight
400 g max.
Manual
W124
SPECIAL I/O MODULES
TEMPERATURE SENSOR MODULES
System Configuration
External Connections
Temperature Sensor Modules
C200H-TS001/TS002/TS101/TS102
High-density
Output Module
C200H-TS101/TS102
Platinum Resistance
Thermometer Input
C200H-TS001/TS002
Thermocouple Input
B0
+
Input 1
A0
--
B0
A
B1
B2
Input 2
A2
--
B1
B2
A
B3
C200HX/HG/HE
Input 1
A0
A1
A1
+
+
B
B′
B
B′
Input 2
A2
B3
A3
A3
B4
B4
--
A4
B’
B5
B5
A
B
A4
R0
G79- C
Connecting
Cable
(1-to-1)
+
M7F
A5
A5
B6
Input 3
A6
--
B6
A
B
B′
A
B
B′
B7
B8
Input 4
A8
--
B9
Note:
B7
A7
A7
+
Input 3
A6
B8
Input 4
A8
B9
A cold junction compensating circuit, whose precision
is adjusted together with the Module, is provided between the B4 and B5 terminals of the C200H-TS001
(for thermocouple).
Temperature Ranges
C200H-TS101
C200H-TS001
Thermocouple
Measuring
element
K (CA) Chromel/Alumel
°C
Unit
°F
°C
Note:
Measurement
ranges
00
01
02 05
06 07 08
03 04
09 10
11
12
Pt 100 Ω
°C
Unit
1,600
1,000
800
Measure- 600
ment
500
ranges
400
300
200
150
100
80
50
0
Temp, spec code
(2-digit BCD)
Platinum Resistance thermometer
Measuring
element
J (IC) Iron/Constantan
13
14
°F
500
400
300
200
150
100
80
50
0
--20
--50
Temp, spec code
(2-digit BCD)
15
16
17 18
21 22 23
19 20
Use the IR bit for setting the temperature range. (Common settings for 4 inputs.)
43
24 25
SPECIAL I/O MODULES
TEMPERATURE CONTROL MODULES
Omron puts accurate temperature control right in the rack to
make advanced PID control with auto-tuning readily accessible.
Eliminates a need for stand-alone controllers with networks.
Display and set parameters with the C200H-DSC01 Data Setting Console. Details on the Data Setting Console are provided
later in this section.
C200H-TC10
C200H-TC00
Features
• Auto-tuning of PID constants
C200H-DSC01
Data Setting
Console
• The temperature controller accepts inputs from a
thermocouple or platinum resistance thermometer. The
module is switch-selectable offering ten different sensor
types.
• Transistor, voltage, or current output can be selected as the
control output.
• High speed and high accuracy temperature control is
performed with a sampling period of 500 ms and with an
indication accuracy of ±0.5%.
• Eight data values such as main set value, alarm set value,
and input shift range can be preset in one data bank and a
maximum of eight data banks can be preset with each bank
preset for a different purpose. It is possible to change the
banks during operation.
• Alarm outputs can be selected out of ten modes, such as an
upper limit, lower limit, and upper/lower limit.
• The heater current is monitored by the high-precision current
transformer (CT) capable of detecting in 0.1 A units. Through
the use of heater burnout detection, heater burnout can be
quickly detected.
• Data input and process value monitoring -- using the Data
Setting Console.
Specifications
44
C200H-TC10
PART NUMBER
C200H-TC00
Current transformer detection current
0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max.
Input points (no. of loops)
Two points (two loops, each of which consists of a temperature sensor and CT)
Temperature control mode
PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning)
Preset memory bank items (8 max.)
Main set value, alarm set value, input shift range, proportional band, integral time, derivative time, sensitivity adjustment, etc.
Setting/Indication accuracy
±0.5% of set (designated) value or ±2°C whichever larger, ±1
digit max.
Proportional band
0.0° to 999.9°C/°F (in units of 0.1°C/°F)
Integral (reset) time
0 to 9,999 s (in units of 1 s)
Derivative (rate) time
0 to 9,999 s (in units of 1 s)
Control period
1 to 99 s (in units of 1 s)
Sampling period
500 ms
Input shift range
--99.9° to 999.9°C/°F (in units of 0.1°C/°F)
Alarm output mode
Selectable from no alarm function, upper alarm, lower alarm, upper/lower alarm, upper-/lower-range alarm, upper/lower alarm
with standby sequence, upper alarm with standby sequence, lower alarm with standby sequence, absolute-value upper alarm,
or absolute-value lower alarm.
No. of banks
8 banks
Internal current consumption
5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage
24 VDC +10%/--15%, 200 mA min.
Weight
360 g max.
Manual
W225
±0.5% of set (designated) value or ±1°C whichever larger, ±1
digit max.
SPECIAL I/O MODULES
TEMPERATURE CONTROL MODULES
CONTROL OUTPUT
SENSOR
PART NUMBER
Transistor output
Thermocou le: R, S, K(CA), J(IC),
Thermocouple:
T(CC) E(CRC)
T(CC),
E(CRC), B
B, N
N, L(IC)
L(IC), U(CC)
C200H-TC001
Voltage output
Current output
Transistor output
Voltage output
Current output
C200H-TC002
C200H-TC003
Platinum resistance thermometer:
JPt100 Pt100
JPt100,
System Configuration
C200H-TC101
Temperature Control
Module
C200HX/HG/HE
C200H-TC102
C200H-TC103
Loop 1
Temperature
sensor
CT
Loop 2
Temperature
sensor
CT
C200H-DSC01
Data Setting
Console
Relay box
for heater
control
45
SPECIAL I/O MODULES
HEAT/COOL TEMPERATURE CONTROL MODULES
Omron puts accurate heat/cool control right in the rack to make
advanced PID control with auto-tuning directly accessible on the
PLC rack. For applications requiring tight process control, such
as plastic extruders. Display and set parameters with the
C200H-DSC01 Data Setting Console.
Features
C200H-TV10
C200H-TV00
• For stable temperature control, use advanced PID and an
auto-tuning feature. ON/OFF control can also be selected.
C200H-DSC01
Data Setting Console
• Dedicated Module available for each Temperature Sensor.
Two types of Temperature Control Module are available,
depending on the thermocouple or platinum resistance
thermometer temperature sensor used.
• Comprehensive output specifications -- three types are
available: C200H-TV
1 for transistor output,
C200H-TV
2 for voltage output, and C200H-TV
3 for
current output.
• Two Heat/Cool Control loops with a single module
• Heater burnout can be quickly detected -- a minimum current
difference of 2.5 A and a heater burnout detection setting
range of 0.1 to 49.9 A allows for the rapid correction.
• Eight banks of data settings, such as set point (SP) and
alarm set values, can be preset in eight data banks for easy
selection.
• Data Input and Display -- The C200H-DSC01 Data Setting
Console (sold separately) is used to input data and display
process values (PV) and set values (SV). The easy-to-read
display can be panel-mounted.
• Data reading/writing User Program of the C200HX/HG/HE
allows reading or writing of various data.
Specifications
C200H-TV10
PART NUMBER
C200H-TV00
Current transformer detection
current
0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max.
Input points (no. of loops)
Two points (two loops, each of which consists of a temperature sensor and CT)
Temperature control mode
PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning)
No. of banks
8 banks
Setting/Indication accuracy (see
note)
±0.5% of set (designated) value or ±2°C whichever larger, ±1
digit max.
Hysteresis
0.0° to 999.9°C/°F (in units of 0.1°C/°F)
Proportional band
0.0° to 999.9°C/°F (in units of 0.1°C/°F)
Integral (reset) time
0 to 9,999 s (in units of 1 s)
Derivative (rate) time
0 to 9,999 s (in units of 1 s)
Control period
1 to 99 s (in units of 1 s)
Sampling period
500 ms
Input shift range
--99.9° to 999.9°C/°F (in units of 0.1°C/°F)
Internal current consumption
5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage
24 VDC +10%/--15%, 200 mA min.
Weight
360 g max.
±0.5% of set (designated) value or ±1°C whichever larger, ±1
digit max.
Manual
W240
Note:
The indication accuracy of thermocouples R and S at a temperature of 200°C max., that of thermocouples K and T at a temperature of --100°C max., and that of thermocouple U are all ±4°C, ±1 digit max. The indication accuracy of thermocouple B at temperature of 400°C or below is not guaranteed.
46
SPECIAL I/O MODULES
HEAT/COOL TEMPERATURE CONTROL MODULES
CONTROL OUTPUT
SENSOR
PART NUMBER
Transistor output
Thermocou le: R, S, K,
Thermocouple:
J T
N L
J,
T, E
E, B
B, N,
L, U
C200H-TV001
Voltage output
Current output
Transistor output
Voltage output
Current output
C200H-TV002
C200H-TV003
Platinum resistance
th
thermometer:
t JPt100
JPt100,
Pt100
C200H-TV101
System Configuration
Heat/Cool
Temperature
Control Module
C200HX/HG/HE
C200H-TV102
C200H-TV103
Loop 1
Temperature
sensor
CT
Loop 2
C200H-DSC01
Data Setting
Console
Relay box
for heater
and coolant
control
Temperature
sensor
CT
47
SPECIAL I/O MODULES
PID CONTROL MODULES
This module provides two independent PID loops for process
control right on the PLC rack. Based on Omron’s E5EX-LA
process controller, the C200H-PID0 accepts both current and
voltage analog inputs for pressure, flow and other measurements. The module can be programmed and controlled from the
PLC or from the optional Data Setting Console. (Details on the
Data Setting console are found later in this section.)
C200H-PID0
C200H-DSC01
Data Setting Console
Features
• Advanced PID -- stable PID control using advanced PID and
an auto-tuning feature. ON/OFF control can also be selected.
• High-speed sampling period of 100 ms -- a sampling period of
100 ms is achieved with two loops, enabling high-speed PID
control.
• Input noise reduction with digital filter -- mitigation of sudden
input fluctuations makes the PID Control Module effective in
quick-response systems.
• Three types of output specification versions are available:
C200H-PID01 for transistor output, C200H-PID02 for voltage
output, and C200H-PID03 for current output.
• Eight banks of data settings -- eight data values, including set
point (SP) and alarm set values, can be preset in eight data
banks for easy selection.
• Data input and display using Data Setting Console to input
data and display process values (PV) and set values (SV).
Easy-to-read display can be panel-mounted.
• Data reading/writing -- the user program of the
C200HX/HG/HE allows reading or writing of various data.
Specifications
48
PART NUMBER
C200H-PID0
Input signal range
4 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V
Input points (no. of loops)
Two points (two loops, each of which consists of a voltage and a current)
Control mode
PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID control with auto-tuning)
No. of banks
8 banks
Setting/Indication accuracy
±0.5% FS ±1 digit max. The SV and displayed value match. There is no relative error.
Hysteresis
0.0 to 100.0% FS (in units of 0.1% FS)
Proportional band
0.0 to 999.9 (in units of 0.1)
Integral (reset) time
0 to 9,999 s (in units of 1 s)
Derivative (rate) time
0 to 9,999 s (in units of 1 s)
Control period
1 to 99 s (in units of 1 s)
Sampling period
100 ms
Input shift range
--999 to 9,999 (decimal point position is designated by a parameter setting)
Internal current consumption
5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage
24 VDC +10%/--15%, 200 mA min.
Weight
360 g max.
Manual
W241
SPECIAL I/O MODULES
PID CONTROL MODULE
OUTPUT
PART NUMBER
Transistor output (open collector)
C200H-PID01
Voltage output
C200H-PID02
Current output
C200H-PID03
System Configuration
PID Control Module
Loop 1
Flow sensor
CT
C200HX/HG/HE
C200H-DSC01
Data Setting
Console
Flow sensor
Relay box for
valve control
Loop 2
CT
49
SPECIAL I/O MODULES
DATA SETTING CONSOLE
The C200H-DSC01 Data Setting Console mounts on the front
panel to display data and provide operator interface for a rackmounted Temperature Controller Module, Cam Positioner Module and PID Modules. You will need one Data Setting Console
to monitor each Module. Included with the C200H-DSC01 are
mounting brackets, panel decals for modules to identify the
modules and a temperature unit label.
Features
• Fits 1/8 DIN cutouts
• 2 m or 4 m cable
• Change set values, parameters
C200H-DSC01
• Monitor present value, set value and memory bank number
as well as output status
Specifications
50
PART NUMBER
C200H-DSC01
Size
1/8 DIN (48 x 96 mm)
Applicable
modules
C200H-TC
C200H-CP114
Display data
Set value, present value, bank number, auto-tuning, heater burnout
alarm, mode, bank, step, cam number, ON/OFF, run, alarm 1 and 2
Connecting
cables
2 m: C200H-CN225
4 m: C200H-CN425
Enclosure
rating
IP20 (For NEMA 4 rating, use a Y29-49N cover.)
C200H-TV
C200H-PID
SPECIAL I/O MODULE
FUZZY LOGIC MODULE
The Fuzzy Coprocessor Module allows state-of-the-art fuzzy
logic inference processing to be closely integrated with Omron’s
C200Hα PLCs. In addition to normal ladder logic control, the
PLC CPU enables pre-processing and post-processing of fuzzy
I/O, which is provided by standard Analog I/O Modules, and/or
internal registers in the PLC CPU, using intelligent I/O READ
and WRITE instructions in ladder logic.
Fuzzy control is best applied to applications that rely heavily on
human control and input such as control for overhead cranes,
flow control, and temperature control.
C200H-FZ001
Features
• Up to 8 inputs, 4 outputs
• Up to 128 rules
• User-definable membership functions
• PLC provides pre-processing and post-processing of fuzzy
I/O
• The C200HX/HG/HE can handle jobs that used to require
highly-experienced operators.
Specifications
PART NUMBER
Fuzzy logic
processor
Membership
functions
I/O words
Peri heral device
Peripheral
i ti
communications
C200H-FZ001
I/O capacity
8 inputs and 4 outputs
Rule format
8 condition and 2 conclusion parts max.
Rule capacity
128 rules max.
Logic process
Forward logic
Logic rule
MAX--MIN logical product
Number of labels
7 max.
Final calculation
Each output can be set independently for calculation by center of gravity, leftmost maximum, or rightmost
maximum method.
Rule with no grade
Can be set to retain the previous value or take a preset value.
Condition
Defined by up to 4 end points. Grade (height) at the end points must be either 0 or 1 (0 or 4095). Resolution is
4095 by 4095.
Conclusion
Only the horizontal position is set. Height is fixed at 4095. Resolution is 4095 by 4095.
Inputs
8 words max. Each input is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to
4095 decimal).
Outputs
4 words max. Each output is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to
4095 decimal).
Communications
Half duplex
Synchronization
Start-stop synchronization
Baud rate
300, 600, 1200, 2400, 4800, 9600, or 19200 (set on DIP switch 2)
Transmission distance
15 m max.
Interface
RS-232C port
Communications protocol
Special procedure (1:N)
Processing time
Self-diagnostics
6 ms max. for Unit, 3 to 4 times the cycle time for system.
Program check
A “memory error” will be generated if an error occurs during the program check.
Data retained in a power interruption
Rules and membership functions are retained.
Internal current consumption
5 VDC, 0.3 A max. (Supplied from the Backplane.)
Weight
400 g max.
Manual
W208
51
SPECIAL I/O MODULES
FUZZY LOGIC MODULE
System Configuration
Analog Output Module
Fuzzy Logic Module
Analog Input Module
Analog inputs
Analog outputs
C200HX/HG/HE
RS-232C cable
(to 9-pin connector)
Fuzzy Support
Software
C500-SU981-E
To 25-pin connector
IBM PC/AT or compatible
52
SPECIAL I/O MODULES
DUAL-AXIS MOTION CONTROL MODULE
The dual-axis motion controllers are compatible with servo
drivers that accept analog inputs for a complete motion control
system. Programs are stored internally in the module and can
be selected and monitored from the extensive memory interface
available in the PLC.
The Motion Control Support Software (MCSS) provides the program editing, downloading, diagnostic, and on-line monitoring
capability to reduce engineering, debugging, and start-up time.
(Order separately.)
Features
C200H-MC221
• Dual-axis semi-closed loop servo control for simple servo
positioning applications
• Internal program storage for fast selection and execution
of motion profiles
• Extensive control and monitoring interface reduces
maintenance and debugging
• G Code Programming Language subset reduces program
development time
• A maximum of 100 programs can be registered
• A maximum of eight modules can be mounted to a single
C200HX/HG/HE PLC to control a maximum of 16 axes.
Write Sophisticated Programs Easily -with G-language Programming and MC Support Software.
The functions of the MC Module are set with the MC
Support Software.
The MC Support Software has well-constructed menu
functions, making it possible to use the MC Module easily.
The function groups of the MC Module are classified with
the system setup menu and the itemized functions of the
MC Module are classified with the main menus.
These are the main menus of the MC Support Software:
MC Program Edit Menu
MC Parameter Edit Menu
Position Data Edit Menu
MC Monitoring Menu
MC Program Edit Menu
MC Parameter Edit Menu
53
SPECIAL I/O MODULES
MOTION CONTROL MODULE
Specifications
PART NUMBER
C200H-MC221
Number of I/O words
20 (2 slots)
External connecting devices
IBM PC/AT or compatible, Teaching Box, and MPG (manual pulse generator)
Controlled driver
Servodrivers that can handle analog inputs
Control
Positioning
Control method
Semi-closed loop using incremental encoder (speed command voltage output)
Number of controlled axes
2 axes max.
Number of simultaneously controlled axes
2 axes max.
PTP (independent) control
Execution by independent programs, operation modes for each axis
Linear interpolation
2 axes max.
Circular interpolation
2 axes max. on a plane
Interrupt inching
Inching on an axis with interrupt input to the axis.
Speed control
Control unit
Minimum unit settings
1, 0.1, 0.01, 0.001, 0.0001 (the unit conversion function is not available.)
Units
mm, inch, degree, pulse
Max. command value
--39,999,999 to +39,999,999
Acceleration//Deceleration curve
Trapezoid or S curve
Acceleration/Deceleration time
0 to 9,998 ms in 2-ms units can be set independently for acceleration and deceleration.
Feed operations
Rapid feed speed
Example: 36.86 m/min.
Interpolation feed speed
Example: 36.86 m/min.
Rapid feed override
0 to 100%
Interpolation feed override
0 to 199%
Conditions
Encoder resolution: 2,048 p/r
/r
Motor speed: 4,500 r/m
Control unit: 0.001 mm/pulse
Setting unit: 0.1%
Jog feed override
0 to 100%
Task program
rogram
managementt
Number of tasks
2 max. (program execution units)
Number of programs
The maximum number of programs differs according to the number of tasks (e.g., 100 programs are controlled if 1 task is used and 50 programs are controlled if 2 tasks are used).
Task program
management
Program capacity
The maximum number of program blocks varies with the number of tasks (e.g., 800 program blocks are
controlled if 1 tasks is used and 400 program blocks are controlled if 2 tasks are used).
Position data capacity
2,000 max. when only 1 axis is used.
Number of registers
32 (mainly used to specify position data numbers)
Sub-program nesting
5 levels max.
M code
0 to 999
Auxiliary function
54
Speed control of up to 2 axes. From 1 to 1,000,000 ppc in single-pulse increments (after quadruplication), if
pulses are used as the unit of control.
Internal current consumption
0.65 A (0.85 A with Teaching Box connected) at 5 VDC
0.2 A at 24 VDC
Weight
500 g max.
Manual
W314, W315, W256
SPECIAL I/O MODULES
MOTION CONTROL MODULE
System Configuration
C200HX/HG/HE/HS/S PLC
MC Support Software (IBM
PC/AT or compatible)
C200H-MC221
MC Module
Manual Pulse
Generator
(MPG)
External input (dedicated cable)
Analog Input
Servodriver
Teaching
Console
Terminal Block
Conversion Unit
2 Axes
CCW limit input
CW limit input
2 generalpurpose
inputs
Origin proximity input
Servomotor
Emergency stop input
55
SPECIAL I/O MODULES
POSITION CONTROL MODULE
Position control modules provide either a step and direction
pulse train or CW/CCW pulse trains to control a single- or dualaxis stepper or servo motor driver. Interface signals include CW
and CCW limits, origin approach, origin stop, emergency stop,
and interrupt signals. Automatic backlash and origin offset functions are now included for precise positioning requirements.
Move parameters can be set up in either ladder logic, or by connecting the hand-held programming console and are stored in
battery-backed memory. Extensive diagnostics are also available to the PLC for quick error detection and troubleshooting.
Features
• Pulse output for stepper motor or servo motor driver
C200H-NC211
• Origin and backlash compensation for precision positioning
C200H-NC112
• Teach mode or storage of calculated movement parameters
• Internal diagnostics
• External signal interface for CW, CCW, origin, emergency
stop, mode, and interrupt
• Parameters, speeds, and positions set in CPU DM area
• Linear interpolation capability on C200H-NC211
Additional Functions -- C200H-NC211 Only
• Simultaneous two-axis control is possible with single-axis
independent control and two-axis linear interpolation.
• Position data or speed data can be changed or transferred
from the PLC to the NC211 while the positioning operation is
stopped.
• Speed can be changed using the speed coefficient, even
during positioning operation.
• Up to 53 positions can be set on both axes.
Specifications
PART NUMBERS
C200H-NC211
C200H-NC112
Axes controlled
2 axes/Module
1 axes/Module
Control system
Automatic trapezoidal acceleration/deceleration
Position
Speed
Data
--8,388,607 to 8,388,606 pulses
Data capacity
53/axis
Data
1 to 250,000 pps
Data capacity
15
Speed adjustment rate
Origin search
56
20
2 to 2,000 pps/1 ms
Origin proximity
None/NO/NC
When provided, H/L level selection is available.
Origin signal
Rise or fall selection
Origin compensation
0 to ±9,999 pulses
Origin search speed
High speed, proximity speed setting available
Backlash compensation
0 to 9,999 pulses
Manual operation
High-speed jog, low-speed jog, inching
I/O words required
20 (Special I/O area)
10 (Special I/O area)
Internal current consumption
5 VDC, 0.5 A max.
5 VDC, 0.2 A max.
Weight
500 g max.
400 g max.
Manual
W166
W128
SPECIAL I/O MODULES
POSITION CONTROL MODULE
Connection Example -- Servo Motor for the Pulse-train Input
Input
Module
C200H-NC211
Position Control Module
AC Servo
Driver
C200HX/HG/HE
AC Servo Driver
XW2ZJ-A2
Connecting Cable
for the C200HNC211
AC
Servomotor
AC Servomotor
XW2B-40J6-2 Connector/Terminal
Conversion Unit for the C200HNC211
57
SPECIAL I/O MODULES
HIGH-SPEED COUNTER MODULE
The high-speed counter modules provide an interface for applications where the counting speed exceeds the PLC’s processing speed. Typical applications include frequency inputs, rotary
encoder interface, position control, cut to length, and motion
control. Built-in I/O and front panel indicators on the module
allow for faster throughput and easy visual monitoring of module
status. Interface signals include count inputs, integral outputs,
and external resets.
Features
C200H-CT021
C200H-CT001-V1
C200H-CT002
Two counters count input signals at a high speed of 75 kcps
max. (C200H-CT021) from Incremental Rotary Encoders or
other sources.
Seven counting modes for varied applications:
Simple counter mode counts input pulses (available with
the C200H-CT021 only)
Drum operations linear mode, circular mode
Preset counter operations -- preset mode
Counting operations -- gate mode (normal and
cumulative), latch mode, sampling mode
• Three input modes available: differential phases, up/down
inputs, pulse and direction inputs
• Provided with multiplication function (x2/x4) for differential
phase input
• Count values can be set in either BCD or HEX
Note: A maximum of 16 C200H-CT021 Modules can be
mounted to a single C200HX-CPU5 -E, C200HXCPU6 -E, C200HG-CPU5 -E, or C200HG-CPU6 -E
CPU.
58
SPECIAL I/O MODULES
HIGH-SPEED COUNTER MODULE
Specifications
PART NUMBER
C200H-CT001-V1
Number of axes
1 axis/Module
2 axes/Module
Operating modes
6
7
Input signal
Encoder inputs A, B
Counter 1 inputs A, B
Counter 2 inputs A, B
Signal level
5, 12, or 24 VDC (selected
when wiring)
Input modes
Differential, up/down, pulse and direction
Counting speed
(see note)
50 kcps
Other
Input multiplier (x2 or x4) available for differential inputs
Input signal
Counter input Z
Counter 1: input Z
Counter 2: input Z
Signal level
External control inputs IN1 and IN2
Counter 1:
external control inputs IN1 and IN2
Counter 2:
external control inputs IN1 and IN2
Count input
External input
RS-422 line driver
(Am26LS31-compatible)
Input signal
Control inputs IN1, IN2
Signal level
5, 12, or 24 VDC (selected when wiring)
Output
External outputs 0 to 7 (8 points)
Output level
External output power supply: 5 to 24 VDC
Switching capacity: 16 to 80 mA
I/O words required
10 (Special I/O area)
Internal current consumption
5 VDC, 0.3 A max.
Weight
400 g max.
Manuals
W141
Note:
RS-422 line driver
(Am26LS31-compatible)
C200H-CT021
12 or 24 VDC (selected when wiring)
RS-422 line driver (Am26LS31-compatible)
75 kcps
5, 12, or 24 VDC (selected
when wiring)
External output
C200H-CT002
12 or 24 VDC (selected when wiring)
RS-422 line driver (Am26LS31-compatible)
12 or 24 VDC (selected when wiring)
5 VDC, 0.4 A max.
305 g max.
W141
W311
Affected by the differential phase pulse input.
System Configuration
A High-speed Counter Module counts input signals from
incremental rotary encoders or other sources.
C200H-CT0
High-speed Counter Module
C200HX/HG/HE
Rotary Encoder (E6A, etc)
Sensor input switch, etc.
59
SPECIAL I/O MODULES
CAM POSITIONER MODULE
The Cam Positioner Module simulates a rotating mechanical
cam, drum sequencer, or programmable limit switch in a PLC
I/O module. The module provides a resolver interface and uses
the Data Setting Console for displaying values.
Features
C200H-CP114
C200H-DSC01
Data Setting Console
• The cam outputs can be set at 16 external outputs and 32
internal outputs with a total of 48 points. The internal outputs
can be taken directly into the C200HX/HG/HE, reducing
wiring inside the control panel.
• The ON/OFF data for the maximum of seven points can be
set for one cam. Data can be registered in one bank. To
facilitate easy set-up changes during operation, a maximum
of eight banks is available for data setting.
• The Data Setting Console allows easy monitoring of cam
data settings, present cam angles, or resolver rpm.
• To provide an optimum output, use the adjustable operation
function to make fine adjustments of the ON/OFF data.
• Data on operating conditions -- such as the present cam
angle, cam outputs for 48 points, resolver rpm, and resolver
status -- can be constantly monitored from the
C200HX/HG/HE side.
• Using origin compensation, the machine origin and the
resolver origin can be easily matched.
• The resolver rpm can be converted into an actual production
quantity by using the scaling function.
Specifications
60
PART NUMBER
C200H-CP114
Output points
48 points (16 external output points, 32 internal output points)
External outputs
NPN transistor open collector (with photo-coupler insulation)
Switching capacity: 100 mA at 24 VDC
Simultaneous ON points: 8 points max.
Resolver cable length
100 m max.
Resolver response rpm
800 rpm max.
Resolver response speed
200 µs (at a sampling frequency of 5 kHz)
Resolver resolution
1°
Program memory
EEPROM (8 banks)
Origin compensation
1° or 359° (The present angle needs to be compensated to 0°)
Internal current consumption
5 VDC, 0.3 A max. (Supplied from the Backplane.)
External power supply
24 VDC +10%/--15%, 2 A min.
Weight
350 g max.
Manual
W224
SPECIAL I/O MODULES
CAM POSITIONER MODULE
System Configuration
Cam Positioner Module
C200HX/HG/HE
3F88L-RS17/17T
3F88L-RS15/15W
Resolver
Solenoid,
DC Input
Module, etc.
C200H-DSC01
Data Setting Console
61
SPECIAL I/O MODULE
ASCII/BASIC MODULE
Two RS-232C Ports
Bidirectional serial interface to
• Computers
• Printers
• Bar code readers
• PLCs
• Other ASCII devices
The ASCII/BASIC Module provides a 24-Kbyte programmable
coprocessor module that operates independently of the PLC.
Two built-in RS-232C ports provide easy interface to a variety of
external devices including other manufacturers’ PLCs, computer
terminals, operator stations, bar code readers, and any other
device utilizing a serial interface. The module is programmable
in either BASIC or Assembly providing a platform for complex
calculations and algorithms at the PLC level. This includes PID,
gas flow calculations and complex math and string manipulation
functions. Communications can be initiated by either the module
or the PLC.
C200H-ASC02
Features
• 24-Kb, battery-backed RAM and 24-Kb EEPROM
programmable in BASIC or Assembly languages
• Special commands to initiate communication with the PLC
• Two RS-232C ports, 19,200 baud maximum speed
• Built-in clock/calendar including year, month, day, date, hour,
minute, second (accurate to 30 seconds/year)
Specifications
62
PART NUMBER
C200H-ASC02
Baud rate
Port 1: 300 to 9,600 bps
Port 2: 300 to 19,200 bps
Transmission distance
15 m max.
Memory capacity
BASIC program area:
24K bytes (RAM)
BASIC program storage area: 24K bytes (EEPROM)
Transmission capacity
255 words max. at 20 words per cycle
Diagnostic functions
CPU watchdog timer, battery voltage drop
Battery life
5 years at 25°C (77°F) The life of the battery is shortened if the Module is used at higher temperatures.
I/O words required
10 (Special I/O area)
Internal current consumption
5 VDC, 0.2 A max.
Weight
400 g max.
Manual
W165
SPECIAL I/O MODULES
ASCII/BASIC MODULE
System Configuration
ASCII/BASIC Module
C200HX/HG/HE
Port 1
(RS-232C)
(RS-232C)
(Programming)
Port 1/Port 2
(I/O)
Keyboard
Printer
Computer
Bar-code reader
Modem
NT-series
Programmable
Terminal
63
SPECIAL I/O MODULES
VOICE MODULE
Use the Voice Module for operator interface messages. Record
up to 60 voice messages on site, or use a tape recorder and
transfer the messages to the module. Messages can also be
uploaded or downloaded through the RS-232C port on the front
panel. The built-in speaker enables immediate message verification. Message length and sound quality are selectable.
Input Devices
• Computer
• Microphone
• Tape recorder
Output Devices
• Computer
• Printer
• Speaker
• Microphone jack enables live message broadcast
• Flexible message length
• Messages can be interrupted to start another message
• Messages can be recorded in phrase and word combination
formats
C200H-OV001
• Upload or download messages through the RS-232C port on
the front panel
Specifications
PART NUMBER
C200H-OV001
Voice synthesis method
Message
Message in
input
ut (switch
(switch-selectable)
selectable)
Message output (switch-selectable)
32, 48, or 64 s (switch selectable)
Capacity
(sentences
and phrases)
60 max.
MIC IN
Microphone input: Unbalanced dynamic microphone (600 Ω)
LINE IN
Tape input: Input impedance: 50 kΩ, unbalanced; Maximum input voltage: 3.3 V
SPEAKER
OUT
Built-in amplifier output: 0.14 W (8 Ω speaker)
LINE OUT
External amplifier output: 600 Ω unbalanced transformer output
Maximum output voltage: 0.5 V rms (effective value)
Both balanced and unbalanced external amplifiers can be connected.
Built-in monitor speaker
Diameter 27 mm, 0.1 W (8 Ω)
Input frequency
32-second recordings: 8 kHz
48-second recordings: 5.3 kHz
64-second recordings: 4 kHz
Output frequency characteristics
32-second recordings: 100 Hz to 3.2 kHz
48/64-second recordings: 100 Hz to 2.2 kHz
Low-pass filter (LPF) selector function (see note)
Cutoff frequency: 3.2 kHz for 32-second recordings, 2.2 kHz for 48/64-second recordings
Message memory
128K bytes RAM (battery powered)
External communication function
(for saving recorded messages)
RS-232C (Baud rate: 19,200/9,600/4,800/2,400 bps. XON/XOFF: yes/no, CTS/RTS: yes/no)
Self-diagnosis function
CPU watchdog timer, LOW battery voltage detection
Battery life
5 years at 25°C (battery life is shorter for higher temperatures)
I/O words required
10 (Special I/O area)
Internal current consumption
5 VDC, 0.3 A max.
Weight
400 g max.
Manual
W172
Note:
64
Adaptive differential pulse-coded modulation (ADPCM)
Recording time
The recording time of the Voice Module is varied by changing the unit’s input frequency. For improved sound quality, the cutoff frequency of the low-pass filter is automatically changed to a lower frequency when the recording time is increased from 32 to either 48 or 64 seconds. (The output frequency is set to 100 Hz to 2.2 kHz when the
recording time is set to 48 or 64 seconds.)
SPECIAL I/O MODULES
VOICE MODULE
System Configuration
Voice Module
C200HX/HG/HE
Voice Output
Voice Input
Microphone
(dynamic, 600 Ω)
Module’s internal
amplifier output
LINE OUT
(600 Ω)
Speaker
(8 Ω, commercially
available)
Cassette tape recorder
(50 kΩ, 3.3 V max., audio use)
External amplifier
Speaker
65
SPECIAL I/O MODULES
RFID SENSOR MODULE
The RFID Modules provide a direct interface to Omron’s V600
and V620 C200H RFID Sensor Read/Write Heads. The module
acts as the controller for Read/Write Heads that exchange data
with data carriers using RF technology. Applications include
conveyor and pallet storage, product labeling, warehousing applications, and more. Up to 8 Kb of data can be stored on a
single data carrier. The interface modules provide a quick and
easy interface to the production line PLC using ladder diagram
programming.
C200H-IDS01-V1
(electromagnetic, for short distances)
C200H-IDS21
(microwave, for long distances)
Features
• Provide flexibility in handling individual workpieces or pallets
by reading product specifications can be read from ID data
carriers (tags)
• Allows up-to-date access information on inventory and
material flow
• System consists of an ID controller or SYSMAC C200H-IDS
Module, Read/Write (R/W) heads, and data carriers (tags)
• Three Read/Write ranges available
• Direct monitoring from the C200H-IDS Module with hand-held
programming console
Specifications
PART NUMBER
C200H-IDS01-V1 AND C200H-IDS21
Communication control procedure
Interactive
Number of R/W Heads (antennas)
connected
One per RFID Sensor Module
Data Carrier (DC)
2K-byte SRAM (with replaceable battery), 8K-SRAM (with built-in battery)
256-byte EEPROM
Data Carrier memory format
8-bit format
Commands
The following seven commands are used:
Read, Write, Auto Read, Auto Write, Clear-all, Auto Read/Write Abort, and Data Management (C200H-IDS01-V1 only)
Data transferrable per instruction
Up to 512 words (1024 bytes) can be transferred at 20 words/scan.
Diagnostic functions
•
CPU watchdog timer
•
Communication errors -- Data Carrier Missing
Six communication errors identify the causes of errors that have occurred during communication between the Data Carrier
and the RFID Sensor Module
•
Error Log
The Error Log function allows communication errors to be displayed in statistical form or in order of occurrence. Error
information is retained by the back-up capacitor.
Monitoring functions
The following monitoring functions are available when the RFID Sensor Module is connected to a Hand-held
Programming Console. Use the keyboard sheet provided with the RFID Sensor Module. (Cable length: 4 m max.)
Read (1 byte)
Stepwise Write (1 byte)
Continuous Write
Test
Error Log
Memory backup
Error information is backed up by a capacitor for 15 days (at 25°C).
I/O words required
5 (Special I/O area)
Internal current consumption
5 VDC, 0.25 A max.
26 VDC, 0.12 A max. (to drive Read/Write Head or R/W Antenna) See note.
Weight
400 g max.
Manual
W153
Note:
66
The Read/Write Head (or Antenna) is supplied 26 VDC. Refer to the C200H PLC Installation Guides (W111 and W218) for information on system design.
SPECIAL I/O MODULE
RFID SENSOR MODULE
System Configuration
C200H-IDS01-V1
RFID Sensor Module
C200HX/HG/HE
Data can be read from
or written to a moving DC.
C200H-CN422 (4 m)
C200H-CN222 (2 m)
Connecting Cable
V600 Read/Write (R/W)
Head (Antenna)
Special keysheet for
RFID Sensor Module
C200H-PRO27-E
Programming Console
V600-D
Data Carrier (DC)
Tests data transmission
and reads out error messages.
Further details on RFID components can be found in Catalog Q80-E3- .
67
68
COMMUNICATIONS
COMMUNICATIONS
Overview
Communication Modules
Fiber-optic Cable and Connections
69
70
72
89
69
COMMUNICATIONS
OVERVIEW
Plant-wide Information Management and
Control Networks
Omron’s advanced plant-wide information management network
capabilities let you harness the power of valuable manufacturing
and production data stored throughout your plant and turn it into
a competitive advantage. Omron’s ethernet connectivity allows
customers to interface PLCs with higher level business
computing systems and other PLCs via Ethernet. To link your
supervisory computers and factory controllers in a seamless,
high-speed, high-capacity network, use Omron’s fiber-optic
based SYSMAC NET communications network. Twin fiber-optic
cables, automatic loopback, and a token ring configuration
provide a reliable, deterministic interface to a variety of
information systems. SYSMAC NET’s fast, 2 Mbps transmission
speed and 2 Kb message size moves large amounts of data
quickly.
Distributed Control Networks
By more tightly integrating their control systems, many
manufacturers have been able to increase productivity and
manufacturing flexibility. Omron’s SYSMAC LINK distributed
control network provides a high speed (2 Mbps) link for
exchanging critical production data between supervisory
computers and programmable controllers in real time.
The token bus peer-to-peer network uses noise resistant
fiber-optic or low cost co-axial cable media for reliable,
deterministic communications. A special data link feature
provides an easy to set up, shared memory system for even
tighter integration between multiple controls and computers.
Operator Interface Terminals on Networks
Omron’s Host Link serial network provides an ideal interface for
today’s data-hungry data acquisition and control software, or
local operator interface. Multiple Operator Interface Terminals
can be connected to a PLC using the Host Link module.
Drivers for this openly available protocol have been developed
for all major third-party operator interface and control software
packages and operator interface devices.
Device-level Networking
Omron offers several options for the networking to factory floor
devices. Omron’s DeviceNet products are compatible with the
DeviceNet specification and provide a variety of distributed I/O
solutions. DeviceNet is an open communications protocol that
allows several vendors’ products to exist on a single network,
giving the customer a wide variety of options to choose from.
Omron’s SYSMAC Bus remote I/O systems significantly lower
wiring and maintenance costs. The SYSMAC Bus remote I/O
connects CPUs and distant I/O using low-cost twisted pair
wiring or fiber-optic cables.
70
COMMUNICATIONS
OVERVIEW
PLANT INFORMATION SYSTEM
Ethernet
CV 500
C200HX/HG/HE
Bridge
PLANTWIDE INFORMATION
SYSMAC NET
MMI computer
C2000H
Line Server
MMI computer
C200H
DISTRIBUTED CONTROL
CV/CVM1
SYSMAC LINK
C200HX/HG/HE
CV1000
CV1000
MMI computer
Master
C200HX/HG/HE
SYSMAC BUS Wired System
Slave
I/O Blocks
C200H Remote
Rack
C500 Remote
Rack
DeviceNet System
Remote
I/O Block
CQM1-DRT21
Branching
SYSMAC BUS Fiber-optic System
C500 Remote
Rack
C200H Remote
Rack
Fiber-optic
Remote I/O
Block
Dedicated
cable
Trunk line
Manifold
Valve
Block I/O
Control
Station
Bar Code
Reader
RS-232C
Interface
DeviceLink Cable
Third-party Products
71
COMMUNICATIONS MODULES
PC CARD MODULES
Connect to ethernet networks with ease and exchange data files
using PCMCIA cards. The PC Card Module provides two
PCMCIA interface slots. Two type-I or type-II cards or one
type-III PCMCIA card can be installed. Using the C200HWPCU01-E, C200Hα memory contents may be written to memory
cards as files, to exchange production data between PLCs and
PCs. Using the C200HW-PCS01-E with an Ethernet-compatible
PCMCIA card, data may be exchanged using FINS protocol via
UDP/IP.
C200HW-PCU01-E
PC Card Module
Features
C200HW-PCS01-E
Ethernet Set
(setup utility driver provided)
Data storage and ease of production stage change with Memory
Cards.
• A standard SRAM or FLASH card inserted into the slot is
used as file storage
• Data can be loaded and saved between the PLC and
memory cards using CMCR (CARD MACRO) instructions
• Data written with the PC Card Module to memory cards is
read with the IBM PC/AT or compatible and vice versa
Communications Board
C200HW-COM01
C200HW-COM04-E
(with RS-232C port)
Connects to Office Networks with Ethernet Cards
• A standard Ethernet Card can be inserted into the slot and,
using the RS-232C port on the front panel, can be set to
allow connection of the C200HX/HG/HE PLC with the
Ethernet
• Data is loaded and saved between the CPU and host
computer by using OMRON’s unique FINS (Factory
Intelligent Network Service) commands. In addition, the PC
Card Module allows the PLC to execute the SEND/RECV
instruction to communicate with the host computer or other
PLCs.
Bus Connection Unit
C200HW-CE011
(for 1 Module)
C200HW-CE012
(for 2 Modules)
PC Card Module Specifications
PART NUMBER
C200HW-PCU01-E
CPU
i80386-SX25 MHz
Memory
1 MB DRAM
ROM
512 KB (for BIOS, DOS, and system file storage)
FLASH ROM
1 MB (for BIOS, DOS, and system file storage)
Serial port
RS-232C x 1 (for terminal connection setup)
PC card interface
PCMCIA 2.1 (3.3-V type is not supported.)
Type x 2 slots or type x 1 slot
Indicators
RUN, ERR, PC card access, and PC card formatting
Power supply
5 VDC (supplied by the Power Supply Unit)
Dimensions
34.5 x 130 x 125 (W x H x D)
Weight
400 g max.
Note:
72
I80386 is a registered trademark of Intel Corp. Ethernet is a registered trademark of Xerox, Corp.
COMMUNICATIONS MODULES
PC CARD MODULE
System Configuration
Data Storage and Easy Production Stage Changes using Memory Cards
C200HX/HG/HE
PC Card Module
Communications Board
Peripheral
devices
such as
Temperature Controller, etc.
Memory card
IBM PC/AT or
compatible
Connects to OA Networks using Ethernet Cards
Production order
data
Host computer
Ethernet
CV-series PLC
Production order
data
CV500-ETN01 Ethernet Module
C200HX/HG/HE
Ethernet Set and PC Card Module
Recommended Memory Cards
MANUFACTURER
PRODUCT
SunDisk compatibles
SDP5100A (FLASH PACKER series)
Intel
IMC001FLKA (FLASH Card)
Note:
OMRON does not guarantee the performance of the above memory cards
although OMRON has confirmed that the above memory cards are suitable
for the PC Card Module.
Recommended Ethernet Cards
MANUFACTURER
PRODUCT
Kingston Technology
KNE-PCM/T
Others
ODI SPEC3 Compatible
73
COMMUNICATIONS MODULES
PC CARD MODULE
Possible Configurations When Installing PC Card Modules
Standard Mounting -- for PC Card Module
C200HW-CE011
Bus Connection Unit
(for 1 Module)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HWPCU01--E PC
Card Module
C200HW-COM01/04-E
Communications Board
C200HW-PCS01-E
Ethernet Set
Mounting with the SYSMAC LINK Module
C200HW-CE012
Bus Connection Unit
(for 2 Modules)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-PCU01-E
PC Card Module
C200HW-PCS01-E
Ethernet Set
C200HWSLK13/23/14/24
SYSMAC LINK
Module
74
C200HW-COM01/04-E
Communications Board
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
SYSMAC NET is a fiber-optic token ring network designed to
transfer large amounts of data between the PLC and IBM PC/AT
Compatible, VME computers, and any ASCII RS-232C devices.
Fiber-optic transmission media provides reliable long distance
communications in harsh environments. Automatic loop-back,
extensive diagnostics, and network utility software provide added reliability and ease of configuration. The C200HS-SNT32
SYSMAC Module is easily integrated to the C200Hα CPU. The
Module connects to the CPU through one of the C200HWCOM01/COM04-E Communications Boards with a C200HWCE001/CE002 Bus Connector.
C200HS-SNT32
Features
• Achieves high-speed and long-distance communications
through Fiber-optic Cables -- N:N token ring
communications method is available. Transmission is
possible with a node separation of 1 km and a data
transmission rate of 2M bits/s. Transmission up to 3 km is
possible when a long-distance repeater is connected.
• Large-scale FA Network configuration -- Up to 126 NSB,
NSU, and SYSMAC NET Link Modules can be connected.
Connect the PLC to a factory computer or host computer
network.
• Improved redundancy capabilities -- The automatic
loop-back and node separation test facilitate the taking of
prompt countermeasures when any abnormality occurs.
Communications Board
C200HW-COM01
C200HW-COM04-E
(w/RS-232C port)
Bus Connection Unit
C200HW-CE001
(for 1 Module)
C200HW-CE002
(for 2 Modules)
• Easy data links between PLCs -- The built-in application
software allows easy data links between PLCs.
• Compatible with H-PCF Fiber-optic Cables -- Possible to
use not only the conventional PCF fiber optic cables but
also H-PCF (hard-clad fiber) Cables. Since solderless
optical connectors can be used, connections on-site have
become easier. (For detailed specifications and ordering
procedures for H-PCF Cables, contact your OMRON
representative.)
Optional Power Supply Module
The SYSMAC Net Module is designed to receive back-up power
supply from the Optional Power Supply Module. Should any
failure of the SYSMAC Net Module occur, the node bypass
function will activate to prevent shutdown of the entire network.
Communication Specifications
ITEM
DESCRIPTION
Communications method
N:N token ring
Transmission method
Manchester code, base band
Data transmission rate
2M bps
Transmission paths
2-conductor fiber optic cable (plastic-clad, crystal
core; core dia.: 200 µm)
Number of nodes
126 max.
Node separation
1 km max.
Message length
2K bytes max.
Send buffer capacity
1 message
Receive buffer capacity
15 messages
Redundancy functions
Automatic loopback
Node bypass
Self-diagnosis function (by test mode function)
Error detection CRC-CCIT
generating function = X16+X12+X5+1
Optional Power Supply Module
C200H-APS01 (for 1 Module
C200H-APS02 (for 2 Modules)
(Optional Power Supply Adapter
required)
Power Supply Connecting Cable
C200H-CN001
(for 1 Module)
C200H-CN002
(for 2 Modules)
75
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
Network Configuration
The SYSMAC NET consists of one line server and a combination of 126 NSB, NSU, and SYSMAC NET Link Modules max.
IBM PC/AT
or compatible
NSB
SYSMAC NET
Host
computer
IBM PC/AT
or compatible
ASCII
Module
RS-232C
Line server
NSB
C-series
PLC
RS-232C
Optical fiber
cable
(2-core)
NSU
Central
Power
Supply
SYSMAC NET
Bridge
NSB
IBM
PC/AT
or
compatible
Power Supply
Adapter
SYSMAC
NET Link
Module
SYSMAC
NET Link
Module
C200HX
/HG/HE
C500
C1000H
C2000H
Back loop
Normal loop
NSB: Network Service Board
NSU: Network Service Module
Bridge: Used for connecting two networks. Up to 20 bridges can be connected in one network provided that it is treated as one node.
SYSMAC NET Link Module: Treated as one node. (It doesn’t function as a bridge. When used together with the SYSMAC LINK Module,
only a total of two Modules can be connected.)
Specifications
76
PART NUMBER
C200HS-SNT32
Transmission direction
1:1
1:N
Data length
1,000 words max. (2,000 bytes)
Only in the same area
Send/Receive data
to/from PLC
The command/response format data for data send or that for
data receive are sent/received if SEND(90) or RECV(98)
has been executed by the program instruction.
Send/Receive data
to/from Module other than
PLC
Command/Response by data send or data receive
Watchdog timer response
1 s (default) or watchdog timer setting value (10 min, 55.35
s max.)
Internal current
consumption
1 A max.
Weight
400 g max.
Manual
W114
Data send/receive
Data send only (no response)
Broadcasting data transfer:
N:126 max.
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
Possible Configurations When Installing SYSMAC NET Link Modules
The following are the possible configurations for installing a
SYSMAC NET Module on a C200Hα CPU Rack.
One Module Mounted
C200HW-CE001
Bus Connection Unit (for 1 Module)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200H-APS01
Power Supply Adapter
(for 1 Module)
C200HW-COM01/04-E
Communications Board
C200HS-SNT32
SYSMAC NET Link Module
Two Modules Mounted
C200HW-CE002
Bus Connection Unit (for 2 Modules)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200H-APS02
Power Supply Adapter
(for 2 Modules)
C200HS-SNT32
SYSMAC NET
Link Module
C200HW-COM01/04-E
Communications Board
With SYSMAC LINK Module
C200HW-CE002
Bus Connection Unit (for 2 Modules)
C200H-APS01
Power Supply Adapter
(for 1 Module)
C200HS-SNT32
SYSMAC NET
Link Module
Note:
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
C200HSSLK13/23/14/24
SYSMAC LINK
Module
Up to two SYSMAC LINK Modules and the SYSMAC NET Link Module can be mounted to the left
of the CPU.
77
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
SYSMAC LINK is a fiber-optic token ring network designed to
transfer large amounts of control data in real-time between
PLCs. Both coaxial and fiber-optic medias may be used.
The C200Hα SYSMAC Link Modules are easily integrated to
the C200Hα CPU. The Modules connect to the CPU through
one of the C200HW-COM01/COM04-E Communications
Boards with a C200HW-CE001/CE002 Bus Connector.
Features
C200HW-SLK23/24
(Coaxial cable)
C200HW-SLK13/14
(Fiber-optic)
• Maximum of 62 SYSMAC LINK Modules -- Up to 62
SYSMAC LINK Modules can be connected in one network. In
addition, two SYSMAC LINK Modules can be mounted on
one PLC, allowing multi-level system configuration.
• Data Modules -- The data link capacity is as large as 2,966
words. High-speed and large-capacity data communications
are possible using the LR area and DM area.
• Flexible Data Link configuration -- Since an optimum data link
table can be created for each node (Machine No.) using the
SYSMAC Support or SYSWIN, the data link area can be
used effectively.
Communications Board
C200HW-COM01
C200HW-COM04-E
(w/RS-232C port)
Bus Connection Unit
C200HW-CE001
(for 1 Module)
C200HW-CE002
(for 2 Modules)
• Event communications -- using the SEND and RECV
instructions, up to 256 words of data can be sent or received
for any node in the network.
• Remote programming or monitoring using the SYSMAC
Support Software -- Programs can be transferred to any
SYSMAC Module within the network and various monitoring
operations can be performed for that Module.
• Built-in LSI exclusively for communications -- The built-in LSI
allows setting of the communication time period between
SYSMAC Modules. The control station is automatically
switched when any trouble occurs in the data link control
station, assuring a highly reliable data link system.
Optional Power Supply Module
The SYSMAC Link Modules are designed to receive back-up
power supply from the Optional Power Supply Module. Should
any failure of the SYSMAC Link Module occur, the node bypass
function will activate to prevent shutdown of the entire network.
C200H-APS03
Optional Power Supply Module
78
Note: Mount the SYSMAC LINK Module to the left of the CPU.
The SYSMAC LINK Module cannot be used with the
C200HE-CPU11-E.
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
Specifications
PART NUMBER
C200HW-SLK23/24 (COAXIAL)
Communications method
N:N token ring
C200HW-SLK13/14 (FIBER OPTIC)
Transmission method
Manchester code, base band
Transmission path
Bus
Data transmission rate
2M bps
Transmission media
Coaxial cable (5C-2V)
Hard-plastic-clad quartz optical fiber
cable
Node separation
1 km max.
10 km max. (800 m max. between
nodes)
Message length
512 bytes max. (256 words)
Connectors
BNC (F Adapter)
Link functions
Data link, data read/write service
Data link words
C200HW-SLK13/23: 918 words max.
C200HW-SLK14/24: 2,966 words max.
Send buffer capacity
1 message
Receive buffer capacity
2 messages
RAS functions
Automatic polling unit backup, self-diagnostics (internode echo tests), failed
node bypass (optical systems only), watchdog timer, error (CRC-CCITT)
detection = X16+X12+X5+1
Current consumption
0.8 A max.
Weight
400 g max.
Manual
W174
Daisy chain
Full, half-lock press-in connector
500 g max.
System Configuration
Coaxial Cable System
Up to 62 nodes separated by a total of 1 km max
IBM PC/AT or
compatible
C200HX/HG/HE
C1000H-TER01
Termination Resistance
is necessary
CVM1
CV500/CV1000/CV2000
SYSMAC LINK Support Board
3G8F5-SLK21-E
C1000H-TER01
Termination Resistance
is necessary
79
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
Fiber-optic System
Up to 62 nodes separated by a total of 10 km max.
with 800 m max between nodes
CVM1
CV500/CV1000/CV2000
C200HX/HG/HE
IBM PC/AT or
compatible
C200H-APS03 Backup
Power Supply Module
(see note 1)
Uninterruptible Power
System (see note 3)
Note:
C1000H-APS01 Backup
Power Supply Module
SYSMAC LINK
Support Board
3G8F5-SLK21-E
Backup Power Supply
(see note 2)
1. The Backup Power Supply is provided with Power Supply Cables (C200H-CN111, C1000H-CN111 for one Module). When supplying power to two Modules simultaneously, order the C200H-CN211 Cable for one Module.
2. The Backup Power Supply Module for a PLC is different in shape from that for a IBM PC/AT or compatible. Be sure to use an appropriate Power Supply.
3. The Backup Power Supply must be separated from the main power supply line to the PLC.
Possible Configurations When Installing SYSMAC Link Modules
One Module Mounted
C200HW-CE001
Bus Connection Units
(for 1 Module)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
C200HW-SLK13/23/14/24
SYSMAC LINK Module
Two Modules Mounted
C200HW-CE002
Bus Connection Unit
(for 2 Modules)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
C200HW-SLK13/23/14/24
SYSMAC LINK Modules
80
COMMUNICATIONS MODULES
DEVICENET SCANNER MODULE
The DeviceNet Scanner Module for the C200Hα allows open
communication over DeviceNet networks with Omron and other
vendors’ I/O products. DeviceNet’s open communications protocol allows the greatest flexibility in design of distributed I/O,
while at the same time reducing installation costs.
Features
• Dedicated cable saves wiring effort -- two nodes are
connected through a single dedicated cable, greatly
reducing installation costs
• Allows T-type bifurcation, branching, and multi-drop wiring.
• Connects to 50 slaves max. for 1,600-point I/O control
possible with the C200HX-, C200HG-, and C200HE-series
Master
C200HW-DRM21
• Network length of 500 meters max. -- possible with a
speed of 125K bps
• Communication at 500K bps max. -- possible with a
network length of 100 m max.
• Conforms to DeviceNet specifications
DeviceNet Communications Specifications
The communications specifications of the DeviceNet Master Module
conform to the DeviceNet communications protocol.
ITEM
SPECIFICATIONS
Baud rate
500K, 250K, or 125K bps (selectable)
Communications
distance
Communications
speed (K bps)
Max.
network
length (m)
Branch
length (m)
Total branch
length (m)
500
100 max.
6 max.
39 max.
250
250 max.
78 max.
125
500 max.
156 max.
Error control
CRC, node address multiple check, and scan list collation
Cable
Dedicated cable
Specifications
PART NUMBER
C200HW-DRM21
Available PLC
C200HX/HG/HE
Max. No. of
connecting PLCs
1
Mounting position
Mounted to the CPU or Expansion I/O Rack. (Cannot be
mounted to the Slave Rack)
Max. no. of I/O
points
1,600
Max. no. of
connecting slaves
50
Manual
W267
81
COMMUNICATIONS MODULES
DEVICENET SCANNER MODULE
System Configuration Example
Master
(800 inputs/800 outputs)
C200HX/HG/HE
Slave
DRT1-HD16s
DRT1-ND16X
Sensor Terminal
(8 sensor input
points)
DRT1-DA02
Analog Output
Terminal
(2 output points)
DRT1-AD04
Analog Input
Terminal
(4 or 2 input points)
DRT1-1D08/16
DRT1-OD08/16
Remote I/O Terminal
(8 or 16 input and
8 or 16 output points)
DRT1-1016X
DRT1-0016X
Remote Adapter
(16 input and 16
output points)
I/O Block
SYSMAC CQM1
Branching
CQM1-DRT21
(16 inputs, 16 outputs)
T-type bifurcation
T-type bifurcation
T-type Bifurcation
Tap
T-type Bifurcation
Tap
Trunk line
Dedicated cable
Other companies’ products
Manifold Valve
Block I/O
Control Station
RS-232C Interface
Bar Code Reader
DeviceLink Cable
T-type Bifurcation Tap
(with termination
resistor)
82
COMMUNICATIONS MODULES
REMOTE I/O MASTER MODULES
The SYSMAC BUS Remote I/O system is ideal for distribution
of I/O and other devices at long distances from the CPU. Multiple remote I/O systems can be connected to a single CPU allowing maximum configuration flexibility.
A SYSMAC BUS Remote I/O system consists of a Remote
Master and one or more Remote Slave modules. Both small
and large rack-style I/O can be mixed in the same remote I/O
system. Remote terminal blocks allow for distribution of 8- and
16-point I/O blocks in a wired remote I/O system. Stand-alone
fiber-optic I/O modules allow distribution of 8-point I/O blocks in
a fiber-optic remote I/O system. I/O Link modules allow connection of a PLC to a fiber-optic remote I/O system. Special link
adapters are available for extended distances and mixing media
types.
Fiber-optic Master
C200H-RM001-PV1
Wired Master
C200H-RM201
Features
• High-speed distribution with twisted pair wiring (saving
both wiring efforts and time) or select fiber-optic cable
versions
• Variety of I/O styles and types in a given remote I/O
system
• RS-485 communications at 187.5 Kbps
• Connect C200H I/O, C500 I/O, G7 remote I/O terminals,
programmable terminals
Note: Remote I/O Master Module cannot be used with a DeviceNet Master Module.
Available Remote I/O Slaves
MODULE
Remote I/O Slave Modules
C200H Slave
Racks
WORDS
ALLOCATED
MAX. IN FIBER-OPTIC SYSTEMS
IR 050 to IR 099
5 (any Expansion I/O Racks connected to Slave Racks must be counted as one additional Slave
each)
C500 Slave
Racks
Fiber-optic I/O Module
Programmable Terminals
MAX. IN WIRED SYSTEMS
2 (If C200H and C500 Slave Racks are both used under the same Master, compute the total for
C200H Slaves, counting each C500 Slave as two C200H Slaves.)
IR 200 to IR 231
32
Cannot connect.
Cannot connect.
8 (4 words allocated to each)
I/O Terminals
32 (1 word allocated to each)
Remote Interfaces
32 (1 word allocated to each)
CQM1
8 (4 words allocated to each)
Note:
I/O links created to C200H
(
(See
note)
When using the above Modules in combination, be careful not to allocate the same words.
83
COMMUNICATIONS MODULES
REMOTE I/O MASTER MODULES
I/O Links to the CQM1
C200HX/HG/HE with
C200H-RM201 Master
Set to #0 at
the CQM1
CQM1 with I/O Link Module
(CQM1-LK501)
IR 200/201
Output
IR 001/002
IR 202/203
Input
IR 100/101
The CQM1 allocates I/O
words according to the slot the
I/O Link Module is mounted to.
System Configuration
Fiber-optic Remote I/O System
C200H-RM001-PV1
Fiber-optic Remote
I/O Master Module
Wired Remote I/O System
(Maximum of two Modules can be
mounted.)
C200H-RT001-P/RT002-P
Remote I/O Slave Module
(Maximum of two Modules can be
C200H-RM201
Wired Remote I/O mounted.)
Master Module
Slave Rack
1-V2
1-V2
C200H-BC
Backplane
C500 Slave Rack (Calculate one
C500 Module as
two C200HX/
HG/HE Modules)
Fiberoptic
Cable
C200H-RT201/RT202 Remote
I/O Slave Module
Slave Rack
C200H-BC
Backplane
5 Slave
Racks max.,
C500 Slave
Rack
counted as 2.
C500 Slave Rack
(Calculate one
C500 Module
as two C200HX/
HG/HE Modules)
Twisted-pair
cable
C500-RT001/002-(P)V1
Remote I/O Slave Module
5 Slave
Racks max.,
C500 Slave
Rack
counted as 2.
C500-RT201
Remote I/O Slave Module
G7TC I/O Block
G71 I/O Interface
I/O Link Module
32 Module
(32 words) max.
Terminator
G72C I/O Terminal
To other Slaves (PTs, I/O Link Modules, etc.)
Fiber-optic I/O
Module
Repeater
Module
Fiber-optic I/O
Module
64 Modules (32 words) max.; Repeater
Module not counted and required for
more than 32 Modules.
84
COMMUNICATIONS MODULES
HOST LINK MODULES
Host Link allows any computer or other communications devices to communicate with one (RS-232C), or several (RS-422)
Omron PLCs. Multiple system levels can be connected to the
same PLC with up to 32 PLCs connected to one computer. Omron’s Host Link protocol is well defined and available for custom
software driver development and operator interface connection
to Omron PLCs. Most major operator interface companies have
Host Link interfaces and drivers available. Host Link systems
allow SYSWIN Programming Software or SSS to program and
monitor any PLC in the system.
When configuring a Host Link system:
• The computer must have one serial port available
• If a fiber-optic, or RS-422 Host Link module is used, Link
Adapters must be included in the system
C200H-LK101-PV1
Host Link Module
(Fiber-optic)
Features
The Host Link protocol is common to all Omron PLCs, including
the CPM1, CQM1, C200H, C200HS, C200HE, C200HG,
C200HX, C1000H, C2000H, and CV-series PLCs.
• Connect up to 32 PLCs to a single host computer
• Use twisted pair or fiber-optic transmission media
On the Host Link Module side:
• IR area can be read or written
• Programs can be uploaded or downloaded
• Up to two Host Link Modules can be connected to a CPU
or Expansion I/O Module. RS-232C, RS-422, and
plastic-clad fiber-optic are available
C200H-LK202-V1
Host Link Module
(RS-422)
• Host Link Modules can be used in combination
(multi-drop) with other C-series Modules
• Host Link Modules can be connected to the Operator
Interface Terminal
C200H-LK201-V1
Host Link Module
(RS-232C)
85
COMMUNICATIONS MODULES
HOST LINK MODULES
System Configuration
Multilevel Host Link System
The following example illustrates the use of the
C200H-LK101-PV1 (fiber-optic) with two personal computers for
system monitoring and data loading.
Fiber-optic Cable
Fiber-optic Cable
Two
Host Link
Modules
3G2A9-AL004-PE
Link Adapter
RS-232C
Host Link Module
RS-232C
Fiber-optic Cable
Host computer
(IBM PC/AT or
compatible) for
system monitoring
Host computer
(IBM PC/AT or
compatible) for
data management
3G2A9-AL004-PE
Link Adapter
Host Link System with SYSMAC Support Software
or SYSWIN
Various functions, such as offline programming or online
monitoring, can be developed by connecting to the IBM PC/AT
or compatible with the use of SYSMAC Support Software or
SYSWIN.
RS-422
3G2A9-AL004
Link Adapter
RS-232C
Host computer (IBM PC/
AT or compatible) with the
C500-ZL3AT1-E SYSMAC
Support Software, or
SYSWIN
C200H-LK202-V1
(as an example)
86
COMMUNICATIONS MODULES
PC LINK MODULES
PC Link is a peer-to-peer communication system allowing highspeed transfer of data between PLCs over long distances. Both
small and large rack PLCs can be connected to the same system. Standard Link Adapters are available for fiber-optic media
and longer transmission distances. No special programming is
required to transfer data, and multi-level systems can be connected to a single PLC.
Features
• High-speed data transfer between up to 32 PLCs
• No special programming required
C200H-LK401
PC Link Module
• Multi-level capability
Specifications
PART NUMBER
C200H-LK401
Communication method
2-conductor, half duplex
Synchronization
HDLC
Transmission speed
128K bps
Transmission method
Broadcasting
Transmission distance
500 m (total cable length in system without optical links, including branch lines)
Max. no. of PLC Link
M d l per S
t
Modules
System
(see note)
PLC of polling unit
Single-level
Multilevel
C200HX/HG/HE, C1000H, or
C2000H
32
16
Transmission LR bits
No. of PC Link Modules
2
3 to 4
5 to 8
9 to 16
17 to 32
C200HX/HG/HE,
C1000H, or C2000H
512
256
128
64
32
Transmission time
35 ms max. (for 128 bits with 8 PLC Link Modules)
Diagnostic functions
CPU watchdog timer, CRC transmission error check
Interface
RS-485
Cable used
Shielded twisted pair
Manual
W135
Note:
Use a 3G2A5-LK009-V1 PLC Link Module when connecting to the C1000H(F) or C2000H.
87
COMMUNICATIONS MODULES
PC LINK MODULES
Multi-level System (4 Levels Max.)
PC Link System Hierarchy
Level 1
Level 3
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC link
PLC link
Level 2
Use a Link Adapter.
Use RS-232C, RS-422, or fiber-optic
cable depending on application.
Level 4
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PC link
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PC link
Usage of Link Relay Area
PLC #0
LR area
Own area
Machine #1
data input area
Machine #2
data input area
Machine #n
data input area
PLC #1
LR area
Machine #0
data input area
Own area
Machine #2
data input area
Machine #n
data input area
PLC #2
LR area
Machine #0
data input area
Machine #1
data input area
Own area
Machine #n
data input area
PLC #3
LR area
Machine #0
data input area
Machine #1
data input area
Machine #2
data input area
Own area
Own area becomes the write area
(send) for the other machine.
Read
(Receive)
Write
(Send)
Own LR
Other
machine’s LR
Other
machine’s LR
Own LR
Read
(Receive)
Write
(Send)
For example, when inputting data
5232 into LR 00 of machine #0, the
data 5232 is output to the LR 00 of
machines #1 to #n.
Application Example
C200HX/HG/HE
CPU Rack
PC Link -- offering high-speed peer-to-peer
communications between PLCs.
• Up to two PC Link Modules can be connected to the
C200HX/HG/HE CPU C200H--LK401or Expansion I/O
Module.
C200HX/HG/HE
Expansion I/O Rack
• The PC Link Module is included in the connectable
number of Special I/O Modules (10 Modules max.).
Although this requires Machine No. setting, it doesn’t
occupy the IR area or DM area.
• Using the split processing of the PC Link Module, PC
Link service can be divided into two, four, or eight
parts, preventing any increase in the cycle time.
88
COMMUNICATIONS
FIBER-OPTIC CABLE AND CONNECTIONS
Omron pioneered the use of fiber-optics for factory floor communications in 1985 by introducing standard fiber-optic interfaces for Remote I/O and all Omron industrial communications
networks. Fiber-optic communications offer distinct advantages
over conventional wiring, including electrical noise immunity and
increased transmission distances.
Recent developments in fiber-optic and communications
technology have provided a variety of cost-effective and
easy-to-install solutions. Simple field termination, lower cable
costs and a variety of fiber-optic cable types allow the effective
use of fiber-optic communications in most industrial
applications.
Omron offers a variety of standard direct-connect fiber-optic
modules for fiber-optic communications. Two types of modules
are available: -P suffix types are for use with APF, HPCF and
PCF Cable types. Non -P suffix types are for use with HPCF
and PCF Cable types. Both of these module types accept the
fiber-optic cable directly. No adapter is needed.
All Plastic Fiber (APF)
All Plastic Fiber is ideal for short transmission distances up to 20
meters in remote I/O, or Host Link communications. Field
termination requires no special tools or skills. APF requires the
use of -P modules. The connectors used with APF are the
3G5A2 connectors.
APF
Hard Plastic-clad Fiber (HPCF)
Hard Plastic-clad Fiber has a 200 micron core cable for
maximum distances of up to 200 meters without repeaters. It is
available in both a zipcord style and a reinforced plastic-jacketed
style with stress relief for pulling through conduit. A termination
tool kit is required for field terminations. Bulk cable lengths up to
1 km are available. The connectors used with HPCF are the
S3200 connectors.
HPCF Zipcord
HPCF Reinforced
89
COMMUNICATIONS
FIBER-OPTIC CABLE AND CONNECTIONS
Plastic-clad Fiber (PCF)
Plastic-clad Fiber is a high performance fiber allowing maximum
distances of up to 800 meters (0.5 mile) without repeaters.
Pre-terminated lengths from 0.1 to 800 meters are available.
Connector bodies can be easily removed for running cable
through ducts, then re-assembled.
PCF Indoor
All Glass Crystal Fiber (AGF)
Special cable and configurations are available for longer
distance requirements, up to 3 km. The maximum transmission
distance with each type of fiber-optic cable is determined by the
kind of Remote I/O or Host Link modules used. These modules
either have a -P or no -P in the part number. The table below
shows maximum transmission distances. Longer distances are
possible using standard repeaters.
PCF Indoor/Outdoor
System Compatibility
The following table shows which Fiber-optic Cable can be used
with each system. The table also shows the maximum length of
each Cable.
FIBER-OPTIC CABLE
APF
HPCF
PCF
SYSMAC BUS with -P modules
20 m
(65 ft.)
—
100 m
(328 ft.)
200 m
(656 ft.)
100 m
(328 ft.)
200 m
(656 ft.)
800 m
(0.5 mile)
200 m
(656 ft.)
800 m
(0.5 mile)
200 m
(656 ft.)
800 m
(0.5 mile)
1000 m
(0.62 mile)
SYSMAC BUS with non -P modules
SYSMAC WAY with -P modules
(C-series only)
SYSMAC WAY with non -P modules
(C-series only)
SYSMAC NET
20 m
(65 ft.)
—
—
A Part Number Summary of Fiber-optic
Cable and Connectors
Refer to the Standard Parts section of this catalog for an
inclusive list of Fiber-optic Connectors and Fiber-optic Cable in
three basic types (offering numerous selections within each
type).
90
PROGRAMMING
PROGRAMMING
Programming Software
SSS and SYSWIN
Protocol Support Software
Programming Peripherals and Cables
Programming Instructions
91
92
94
97
99
91
PROGRAMMING SOFTWARE
SYSWIN OR SSS
Overview of Software Options
C200Hα CPUs can be programmed using Omron’s SYSWIN
Programming Software. SYSWIN is a Microsoft
Windows-based programming and documentation
application. SYSWIN provides you with an easy and intuitive
graphical user interface designed for use with all of Omron’s
C and CV series PLCs. SYSWIN also offers a
comprehensive range of functions for the PLC programmer,
from program editing to full symbolic and network debugging.
System Information
PLCS SUPPORTED
CPM1, C**K, C**H, CQM1, C200H, C200HS, C500,
C1000H, C2000H, C200HE, C200HG, C200HX,
CVM1+EV
Communications
SYSMAC NET, SYSMAC LINK, HOST LINK
Computer requirements
486DX2/50
RAM Capacity
2 or 4 MB RAM minimum
Free disk space
8Mb of free hard disk space
Floppy disk drive
3.5” double density
Communication port
1 or 2, with RS--232C port or RS--422
Video
Color VGA or better
C200Hα CPUs can also be programmed using
Omron’s SSS DOS programming packages.
Save time with Easy and Intuitive Programming
SYSWIN provides you with fast and easy programming
operations. With simple point and click editing, creating ladder
logic is a snap. Not sure about which function to use? SYSWIN
provides you with a quick categorization of PLC functions and
extensive on-line help. First time users will find it easy to learn
while working with Omron’s PLCs and Software.
Powerful Editing
Extensive editing features of SYSWIN lets you create and
modify programs quickly and easily. Cut and paste library
functions let you take advantage of your existing code. In
addition, you can easily find and replace program addresses
and documentation throughout your program.
92
PROGRAMMING SOFTWARE
SYSWIN OR SSS
Documentation
Need to document your program? SYSWIN gives you lots of
room for commenting addresses (30 characters), networks, and
blocks of programs (up to 32K per). In addition, managing your
documentation is easy using the Address Symbol Editor. With
the Address Symbol editor you get all of our internal relays
already documented as well as a summary of all addresses
used in the program and documentation. Simply select a new
address for your program and choose from the documentation.
In addition you can sort your documentation by address or
symbol.
Extensive Monitoring Tools
SYSWIN programming software let’s you monitor bit status,
specified I/O status, word content, or Data memory on-line. With
the Data Display, monitoring large areas of memory is made
easy. Different areas of memory can be monitored
simultaneously -- as well as in different data formats, such as
hex, decimal, binary, ASCII, and floating point.
Powerful Cross Reference
SYSWIN’s address cross referencer is great tool for debugging
your program. With a simple point and click you can view all
your addresses, location and usage while also viewing ladder
logic. Then simply click on any address and your ladder logic
automatically moves to the location of address.
93
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
Overview
The C200HW-COM04-E, C200HW-COM05-E, and
C200HW-COM06-E Communication Boards have a protocol
macro capability. The Protocol Support Software makes it
possible to customize communication sequences by using the
protocol macro. The Protocol Support Software supports seven
types of standard communications sequences -- to either
customize or use as they are.
• The conversational-type menu of the Protocol Support
Software allows communication sequences to be
registered easily.
• The Protocol Support Software allows a maximum of
1,000 communication sequences to be registered, each
having 16 steps max.
• Each of the registered communication sequences can
include data for the transmission method, link word,
monitor period, and response advice method to be used
with the registered communication sequence. X-ON and
X-OFF flow control, RS and CS flow, modem control,
delimiter control and the contention method are supported
by the Protocol Support Software.
• Each of the steps can include data for the repetition
number, a communication command, communication
message, reception matrix, the next process to be
executed, and the error processing command to be
executed if the step has an execution error.
• Any destination address or communications data set with
the Protocol Support Software can include variable N,
wildcard, and word call settings. Whenever a step is
repeated, the value of variable N in the step will increase
by one. Because of this, a message can be transmitted to
more than one address continuously, or the table data
stored in any word can be transmitted continuously.
• The Protocol Support Software automatically allows
transmission of any communication message with an error
check code, such as SUN, LRC, or CRC, and data for the
length of the communication message. At the destination
address of the communication message, the Protocol
Support Software allows the checking of the
communication message according to the error check
code and the data for the length of the communication
message so the destination address can receive the
communication message correctly.
• The process can be defined with an END, GOTO, NEXT, or
ABORT that is executed right after each step is executed
with or without any error.
• A maximum of 15 types of expected reception messages
can be set with a reception matrix. Each of the expected
reception messages can include data that determines the
next process to be executed and the error processing
command to be executed if there is a message reception
error.
Note: Refer to the Protocol Support Software Operation Manual (W305) for details.
94
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
System Settings
C200HW-ZW3AT1-E
Protocol Support Software
Set communication conditions according to the application when
using the protocol macro for communication. The standard
communication conditions are shown here.
ITEM
SPECIFICATIONS
No. of start bits
1
Data length
7 bits
Parity
Even
No. of stop bits
2
Baud rate
9,600 bps
C200HX/HG/HE
Standard measuring devices,
components, and personal
computers
RS-232C
Asynchronous (start-stop synchronization) communication
Modem
Visual Inspection
System
Intelligent Signal Processor
ID Controller
Temperature
Controller
Bar code reader
Laser micrometer
System Configuration
Using the protocol macro, you can customize communications
sequences for a variety of communications devices that use
RS-232C, RS-422, or RS-485 lines. Refer to the following
system configuration.
Configuration of Communication Sequences -- A maximum of
1,000 communications sequences (i.e., communications
sequences 0 to 999) can be registered, each consisting of 16
steps max.
Starts processing
Protocol
macro
executed
PMCR
Port B: 28912
Port A: 28908
Step 0
Port
Port B
specification 2
Sequence no. for port
specification + communications sequence no.
No. of first word of
output data
to
Communications
sequence 000
Step 15
to
Step 0
Communications
sequence 999
to
No. of first word of
input data
Step 15
Port A
Port
specification 1
Step 0
Communications
sequence 000
to
Step 15
to
Communications
sequence 999
Step 0
to
Step 15
95
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
E5AJ Temperature Controller Connection Example
Connections
C200HX
AL001
RS-422
RS-422
RS-422
RS-422
#0
RS-422
RS-422
#1
#2
#3
RS-422
Port A
E5AJ-A2H02
E5AJ-A2H02
E5AJ-A2H02
E5AJ-A2H02
Program Example
In this example, the E5AJ is set to a target value.
Start
condition
PMCR
execute flag
Port A specification with communications sequence 205
@PMCR
Setting Units and Values
#1205
DM0506
DM1000
DM word
Set data
Meaning
DM 0506
DM 0507
DM 0508
0003
0003
0085
No. of words for transmission data
Unit no.
Target value (85°C)
End Code:
This communications sequence is set to any word because there is
no reception data for the communications sequence.
96
PROGRAMMING PERIPHERALS AND CABLES
OVERVIEW
These are the devices available for programming and diagnostics.
C200H-LK201-V1
C200HX/HG/HE
Mounted
directly
Host Link Module
RS-232C
port
CONNECTING
CABLES
C200H-CN222/422
(2 m/4 m)
Programming Console
Connecting Cable
C200HS-CN220-EU
C200HS-CN229-EU
C500-CN221-EU
C500-CN222-EU
Connecting Cable
Peripheral
port
CQM1-CIF02
Connecting Cable
C500-ZL3AT1-EV1.2
PERIPHERAL
DEVICE
SYSWINHL-V3.1
SUPPORT
SOFTWARE
IBM PC/AT or Compatible
Programming Console for C200H
C200H-PRO27-E
SYSMAC
Support Software
SYSWIN
Programming Console
CQM1-PRO01-E
97
PROGRAMMING PERIPHERALS AND CABLES
OVERVIEW
Programming Consoles
C200H-PRO27-E
Programming
Console
CQM1-PRO01-E
Programming Console
There are two programming consoles that can be used with the
C200HX/C200HG/C200HE: The C200H-PRO27-E and the
CQM1-PRO01-E. The programming console is a complete online and off-line programming and monitoring hand-held console. In addition to programming and monitoring with the programming console, users can verify programs, compare and
create I/O tables, monitor multiple I/O, force set/reset bits, and
choose from run, monitor, debug or program modes.
The C200H-PRO27-E Programming Console connects to the
C200HX/C200HG/C200HE CPU peripheral port with
C200H-CN222 or C200H-CN422 Connecting Cable (cable
purchased separately).
The CQM1-PRO01-E Programming Console comes with a 2 m
connecting cable which connects to the C200HX, C200HG, or
C200HE CPU peripheral port.
C200H-CN222/422
Programming Console
Connecting Cable
(2 m/4 m)
Connecting Cables
CQM1-CIF02
Connecting Cable
98
C200HS-CN220-EU
C200HS-CN229-EU
C500-CN221-EU
C500-CN222-EU
Connecting Cable
There are several cables which allow you to connect a PC to
the C200HX/HG/HE for programming and monitoring, using
SYSWIN or SSS. The C200HS-CN220-EU (9-pin RS-232C) and
the C200HS-CN229-EU (25-pin RS-232C) cables connect a PC
to a built-in RS-232C port of the C200HX/HG/HE CPU. The
C500-CN221-EU (9-pin RS-232C) and C500-CN222-EU (25-pin
RS-232C) cables connect a PC to a rack-mounted
C200H-LK201-V1.
PROGRAMMING INSTRUCTIONS
GENERAL INFORMATION AND BASIC INSTRUCTIONS
General Information
• An instruction marked with “@” can be used as a differentiated instruction that will be executed only
once each time the instruction executing condition is turned ON.
• An instruction marked with “ ” is an expansion instruction. These instructions must be assigned
function codes before they can be used.
• An instruction marked with “ ” is an expansion instruction. The assigned function code is the
default for the C200HX/HG/HE PLC.
Basic Instructions
NAME MNEMONIC
•
•
•
SYMBOL
FUNCTION
LOAD
LD
B
Defines the status of bit B as the execution condition for
subsequent operations in the instruction line.
LOAD NOT
LD NOT
B
Defines the status of the inverse of bit B as the execution condition for subsequent operations in the instruction line.
AND
AND
B
Logically ANDs the status of the designated bit with the
current execution condition.
AND NOT
AND NOT
B
Logically ANDs the inverse of the designated bit with
the current execution condition.
OR
OR
B
Logically ORs the status of the designated bit with the
current execution condition.
OR NOT
OR NOT
B
Logically ORs the inverse of the designated bit with the
execution condition.
AND LOAD
AND LD
Logically ANDs the resultant execution conditions of the
preceding logic blocks.
OR LOAD
OR LD
Logically ORs the resultant execution conditions of the
preceding logic blocks.
OUTPUT
OUT
B
Turns ON B for an ON execution condition; turns OFF
B for an OFF execution condition.
OUTPUT NOT
OUT NOT
B
Turns OFF B for an ON execution condition; turns ON
B for an OFF execution condition.
SET
SET
SET B
Turns the operand bit OFF when the execution condition is ON, and does not affect the status of the operand
bit when the execution condition is OFF.
RESET
RSET
RST B
Turns the operand bit ON when the execution condition
is ON, and does not affect the status of the operand bit
when the execution condition is OFF.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
99
PROGRAMMING INSTRUCTIONS
BASIC INSTRUCTIONS (CONTINUED)
SYMBOL
NAME MNEMONIC
CP
COUNTER
CNT
FUNCTION
CNT N
R
SV
REVERSIBLE COUNTER
CNTR (12)
II
DI
R
TIMER
TIM
CNTR(12)
N
SV
TIM N
A decrementing counter. SV: 0 to 9999; CP: count
pulse; R: reset input. The TC bit is entered as a constant.
Increases or decreases the PV by one whenever the increment input (II) or decrement input (DI) signals, respectively, go from OFF to ON. SV: 0 to 9999; R: reset
input.
ON-delay (decrementing) timer operation. Set value:
000.0 to 999.9 s.
SV
TOTALIZING TIMER
TTIM(87)
TTIM(87)
N
SV
RB
HIGH- SPEED TIMER
TIMH(15)
TIMH(15) N
Creates a totalizing timer.
A high-speed, ON-delay (decrementing) timer. SV:
00.02 to 99.99 s. The TC bit is entered as a constant.
SV
END
END(01)
INTERLOCK
IL(02)
INTERLOCK CLEAR
ILC(03)
END(01)
Required at the end of each program. Instructions located after END(01) will not be executed.
IL(02)
Creates interlocks used to control execution of program
sections. The entire section is reset when execution is
completed.
ILC(03)
JUMP
JMP(04)
JUMP END
JME(05)
JMP(04)
N
JME(05)
N
S
KEEP
KEEP(11)
JUMP transfer program execution to the JUMP END
with the same number.
Defines a bit (B) as a latch, controlled by the set (S) and
reset (R) inputs.
KEEP(11)
B
R
•
•
•
100
NO OPERATION
NOP(00)
None
Nothing is executed and program operation moves to
the next instruction.
DIFFERENTIATE UP
DIFU(13)
DIFU(13) B
DIFU(13) turns ON the designated bit (B) for one cycle
on reception of the leading (rising) edge of the input signal.
DIFFERENTIATE DOWN
DIFD(14)
DIFD(14) B
DIFD(14) turns ON the bit for one cycle on reception of
the trailing (falling) edge.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS
NAME MNEMONIC
SYMBOL
BCD-TO- BINARY
(@)BIN(23)
BIN(23)
S
R
FUNCTION
Converts 4-digit, BCD data in source word (S) into
16-bit binary data, and outputs converted data to result
word (R).
S
(BCD)
DOUBLE BCD-TO-DOUBLE
BINARY (@)BINL(58)
BINL(58)
S
R
R
(BIN)
x100
x160
x101
x161
x102
x162
x103
x163
Converts the BCD value of the two source words (S:
starting word) into binary and outputs the converted
data to the two result words (R: starting word).
R
S
S+1
BINARY-TO- BCD
(@)BCD(24)
BCD(24)
S
R
R+1
Converts binary data in source word (S) into BCD, and
outputs converted data to result word (R).
S
(BIN)
DOUBLE BINARY-TO-DOUBLE
BCD
(@)BCDL(59)
BCDL(59)
S
R
R
(BCD)
x160
x100
x161
x101
x162
x102
x163
x103
Converts the binary value of the two source words (S:
starting word) into eight digits of BCD data, and outputs
the converted data to the two result words.
R
S
S+1
BIT COUNTER
(@)BCNT(67)
BCNT(67)
N
SB
R
•
•
•
R+1
Counts the number of ON bits in one or more words.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
101
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
4-TO-16 DECODER
(@)MLPX(76)
MLPX(76)
S
Di
R
FUNCTION
Converts up to four hexadecimal digits in the source
word (S), into decimal values from 0 to 15, and turns
ON the corresponding bit(s) in the result word(s) (R).
S
0 to F
R
15
16-TO-4 ENCODER
(@)DMPX(77)
DMPX(77)
S
R
Di
00
Determines the position of the leftmost ON bit in the
source word(s) (starting word: S) and turns ON the corresponding bit(s) in the specified digit of the result word
(R).
15
00
S
R
7-SEGMENT DECODER
(@)SDEC(78)
SDEC(78)
S
Di
D
0 to F
Converts hexadecimal values from the source word (S)
into 7-segment display data. Results are placed in consecutive half-words, starting at the first destination
word (D)
S
0 to F
D
ASCII CONVERT
(@)ASC(86)
ASC(86)
S
Di
D
Converts hexadecimal digits from the source word (S)
into 8-bit ASCII values, starting at leftmost or rightmost
half of the starting destination word (D).
S
0 to F
8-bit
D
data
15
2’S COMPLEMENT
(@)NEG
NEG(--)
S
R
---
DOUBLE 2’S COMPLEMENT
(@)NEGL
•
•
•
102
NEGL(--)
S
R
---
08
07
00
Converts the four-digit hexadecimal content of the
source word to its 2’s complement and outputs the result to R.
Converts the eight-digit hexadecimal content of the
source words to its 2’s complement and outputs the result to R and R+1.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
ASCII-TO-HEXADECIMAL
(@)HEX
FUNCTION
Converts ASCII data to hexadecimal data.
HEX(--)
S
Di
D
Di: 0011
S
1st
D
byte
0
2nd byte
1
2
3
LINE
(@)LINE(63)
LINE(63)
S
C
D
LINE-TO- COLUMN
(@)COLM(64)
COLM(64)
S
D
C
HOURS-TO- SECONDS
(@)SEC(65)
SEC(65)
SECONDS- TO-HOURS
(@)HMS(66)
HMS(66)
ARITHMETIC PROCESS
(@)APR(69)
APR(69)
C
S
D
S
R
------
S
R
------
•
•
•
Fetches data from the same numbered bit (C) in 16 consecutive words (where S is the address of the first
source word), and creates a 4-digit word with them.
Bit C
D
S
0
0
00
S+1
1
1
01
S+15
0
0
15
Places bit data from the source word (S), consecutively
into the same numbered bits of the 16 consecutive destination words.
S
Bit C
00
1
1
D
01
1
1
D+1
15
0
0
D+15
Converts a time given in hours/minutes/seconds (S
and S+1) to an equivalent time in seconds only (R and
R+1).
Converts a time given in seconds (S and S+1) to an
equivalent time in hours/minutes/seconds (R and
R+1).
Calculates the cosine, or sine of the given degree value,
or determines the y-coordinate of the given x value in a
previously established line graph.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
103
PROGRAMMING INSTRUCTIONS
SPECIAL PROCESSING INSTRUCTIONS
SYMBOL
NAME MNEMONIC
FUNCTION
TRACE MEMORY SAMPLING
TRSM(45)
TRSM(45)
Initiates data tracing.
DISPLAY MESSAGE
(@)MSG(46)
MSG(46)
Displays eight words of ASCII code, starting from FM,
on the Programming Console or GPC.
FM
FM
FM+ 7
A
B
C
D
D
P
ABCD........DP
LONG MESSAGE
(@)LMSG(47)
LMSG(47)
S
D
------
SCALING
(@)SCL
SCL(--)
S
P1
R
DATA SEARCH
(@)SRCH
SRCH(--)
N
R1
C
Finds the maximum value in specified data area and
outputs that value to another word.
FIND MINIMUM
(@)MIN
MIN(--)
C
R1
D
Finds the minimum value in specified data area and outputs that value to another word.
SUM
(@)SUM
SUM(--)
C
R1
D
Computes the sum of the contents of the words in the
specified range of memory.
104
Searches the specified range of memory for the specified data. Outputs the word address(es) of words in the
range that contain the data.
MAX(--)
C
R1
D
•
•
Performs a scaling conversion on the calculated value.
FIND MAXIMUM
(@)MAX
•
Outputs a 32-character message to either a Programming Console, or a device connected via the RS-232C
interface. The output message must be in ASCII beginning at address S.
R1
R1+1
R1+2
R1+3
MSB
1
3
5
7
LSB
2
4
6
8
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
SPECIAL PROCESSING INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
FRAME CHECKSUM
(@)FCS
FCS(--)
C
R1
D
AVERAGE VALUE
(@)AVG
AVG(--)
S
N
D
FAILURE POINT DETECTION
FPD
PID CONTROL
PID
•
•
FPD(--)
C
T
D
PID(--)
S
C
D
•
FUNCTION
Checks for errors in data transmitted by a
Host Link command.
R1
R1+1
R1+2
R1+3
MSB
1
3
5
7
LSB
2
4
6
8
Adds the specified number of hexadecimal words and
computes the mean value. Rounds off to 4 digits past
the decimal point.
Finds errors within an instruction block.
PID control is performed according to the operand and
PID parameters that are preset.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
105
PROGRAMMING INSTRUCTIONS
DATA SHIFTING INSTRUCTIONS
SYMBOL
NAME MNEMONIC
FUNCTION
I
SHIFT REGISTER
SFT(10)
P
R
Creates a bit shift register for data from the starting
word (St) through to the ending word (E).
SFT(10)
St
E
15
00
15
00
E
REVERSIBLE SHIFT
REGISTER
(@)SFTR(84)
SFTR(84)
C
St
E
St
IN
Shifts bits in the specified words either left or right.
Starting (St) and ending words (E) must be specified.
15
00
15
E
00
S
t
IN
CY
15
00
15
E
IN
00
St
CY
ASYNCHRONOUS SHIFT REGISTER
(@)ASFT(17)
ASFT(17)
C
St
E
WORD SHIFT
(@)WSFT(16)
WSFT(16)
St
Creates and controls a reversible non-synchronous
word shift register between St and E. Exchanges the
content of a word containing zero with the content of either the preceding or following word, depending on the
shift direction.
The data in the words from the starting word (St)
through to the ending word (E), is shifted left in word
units, writing all zeros into the starting word.
E
ARITHMETIC SHIFT LEFT
(@)ASL(25)
ASL(25)
Wd
Each bit within a single word of data (Wd) is shifted one
bit to the left, with zero written to bit 00 and bit 15 moving
to CY.
15
CY
ARITHMETIC SHIFT RIGHT
(@)ASR(26)
ASR(26)
Wd
15
•
•
106
0
Each bit within a single word of data (Wd) is shifted one
bit to the right, with zero written to bit 15 and bit 00 moving to CY.
0
•
00
Wd
00
Wd
CY
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
DATA SHIFTING INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
ROTATE LEFT
(@)ROL(27)
ROL(27)
Wd
FUNCTION
Each bit within a single word of data (Wd) is moved one
bit to the left, with bit 15 moving to carry (CY), and CY
moving to bit 00.
15
00
CY
Wd
ROTATE RIGHT
(@)ROR(28)
ROR(28)
Wd
Each bit within a single word of data (Wd) is moved one
bit to the right, with bit 00 moving to carry (CY), and CY
moving to bit 15.
15
CY
ONE DIGIT SHIFT LEFT
(@)SLD(74)
SLD(74)
St
E
00
Wd
Shifts all data, between the starting word (St) and ending word (E), one digit (four bits) to the left, writing zero
into the rightmost digit of the starting word.
St
0
St + 1
E
ONE DIGIT SHIFT RIGHT
(@)SRD(75)
SRD(75)
E
St
Shifts all data, between starting word (St) and ending
word (E), one digit (four bits) to the right, writing zero into
the leftmost digit of the ending word.
E
E -- 1
St 0
•
•
•
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
107
PROGRAMMING INSTRUCTIONS
BCD ARITHMETIC INSTRUCTIONS
SYMBOL
NAME MNEMONIC
BCD ADD
(@)ADD(30)
FUNCTION
ADD(30)
Au
Ad
R
Adds two 4-digit BCD values (Au and Ad) and content
of CY, and outputs the result to the specified result word
(R).
CY
Au + Ad +
DOUBLE BCD ADD
(@)ADDL(54)
ADDL(54)
Au
Ad
R
R
Adds two 8-digit values (2 words each) and the content
of CY, and outputs the result.
+
Au+ 1
Au
Ad+ 1
Ad
+
CY
CY
BCD SUBTRACT
(@)SUB(31)
SUB(31)
Mi
Su
R
R+ 1
SUBL(55)
Mi
Su
R
R
Subtracts both the 4-digit BCD subtrahend (Su) and
content of CY, from the 4-digit BCD minuend (Mi) and
outputs the result to the specified result word (R).
Mi -- Su --
DOUBLE BCD SUBTRACT
(@)SUBL(55)
CY
R
--
Mi
Su
Su + 1
--
CY
CY
MUL(32)
Md
Mr
CY
Subtracts both the 8-digit BCD subtrahend and the content of CY from an 8-digit BCD minuend, and outputs
the result.
Mi + 1
BCD MULTIPLY
(@)MUL(32)
CY
R+ 1
R
Multiplies the 4-digit BCD multiplicand (Md) and 4-digit
BCD multiplier (Mr), and outputs the result to the specified result words (R and R + 1).
R
R+1
Md x Mr
DOUBLE BCD MULTIPLY
(@)MULL(56)
MULL(56)
Md
Mr
R
Multiplies the 8-digit BCD multiplicand and 8-digit BCD
multiplier, and outputs the result.
X
R+3
•
•
•
108
R
Md+ 1
Md
Mr+ 1
Md
R+2
R+1
R
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
BCD ARITHMETIC INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
BCD DIVIDE
(@)DIV(33)
FUNCTION
DIV(33)
Dd
Dr
R
Divides the 4-digit BCD dividend (Dd) by the 4-digit
BCD divisor (Dr), and outputs the result to the specified
result words. R receives the quotient; R + 1 receives the
remainder.
Dd ÷ Dr
DOUBLE BCD DIVIDE
(@)DIVL(57)
DIVL(57)
Dd
Dr
R
R+1
R
Divides the 8-digit BCD dividend by an 8-digit BCD divisor, and outputs the result.
Dd + 1
Dd
Dr + 1
Dr
Quotient
R+1
R
Remainder
R+3
R+2
÷
SET CARRY
(@)STC(40)
STC(40)
Sets the Carry Flag (i.e., turns CY ON).
CLEAR CARRY
(@)CLC(41)
CLC(41)
Clears the Carry Flag (i.e, turns CY OFF).
INCREMENT
(@)INC(38)
INC(38)
Wd
Increments the value of a 4-digit BCD word (Wd) by
one, without affecting carry (CY).
DECREMENT
(@)DEC(39)
DEC(39)
Wd
Decrements the value of a 4-digit BCD word by 1, without affecting carry (CY).
SQUARE ROOT
(@)ROOT(72)
ROOT(72)
Computes the square root of an 8-digit BCD value (Sq
and Sq + 1) and outputs the truncated 4-digit, integer result to the specified result word (R).
Sq
R
Sq+1
Sq
R
FLOATING POINT
DIVIDE
(@)FDIV(79)
FDIV(79)
Dd
Dr
R
Divides one floating point value by another and outputs
a floating point result.
÷
•
•
•
Dd+ 1
Dd
Dr+ 1
Dr
R+1
R
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
109
PROGRAMMING INSTRUCTIONS
ADVANCED I/O INSTRUCTIONS
SYMBOL
NAME MNEMONIC
TEN KEY INPUT
TKY
TKY(--)
IW
D1
D2
HKY(--)
IW
OW
D
This instruction inputs 8 digits in hexadecimal from a
hexadecimal keyboard.
DIGITAL SWITCH INPUT
DSW
DSW(--)
IW
OW
R
Inputs 4- or 8-digit BCD data from a digital switch.
7-SEGMENT DISPLAY OUTPUT
7SEG
7SEG(--)
S
O
C
Converts 4- or 8-digit BCD data to 7-segment display
format and then outputs the converted data.
MATRIX INPUT
MTR
MTR(--)
IW
OW
D
•
•
110
Inputs 8 digits of BCD data from a 10-key keypad.
HEXADECIMAL KEY INPUT
HKY
•
FUNCTION
Inputs data from an 8 input point × 8 output point matrix
and records that data in D to D+3.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
SUBROUTINE INSTRUCTIONS
SYMBOL
NAME MNEMONIC
SBS(91)
N
Calls subroutine N. Moves program operation to the
specified subroutine.
SUBROUTINE DEFINE
SBN(92)
SBN(92)
N
Marks the start of subroutine N.
SUBROUTINE RETURN
RET(93)
MACRO
(@)MCRO(99)
INTERRUPT CONTROL
(@)INT(89)
•
•
•
FUNCTION
SUBROUTINE ENTRY
(@)SBS(91)
RET(93)
Marks the end of a subroutine and returns control to the
main program.
MCRO(99)
N
I1
O1
Calls and executes a subroutine replacing I/O words.
INT(89)
CC
N
D
Controls scheduled interrupts and interrupts from Interrupt Input Units.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
111
PROGRAMMING INSTRUCTIONS
DATA COMPARISON INSTRUCTIONS
SYMBOL
NAME MNEMONIC
COMPARE
(@)CMP(20)
SIGNED BINARY COMPARE
(@)CPS
DOUBLE COMPARE
CMPL(60)
DOUBLE SIGNED BINARY
COMPARE
(@)CPSL
BLOCK
COMPARE
(@)BCMP(68)
FUNCTION
CMP(20)
Cp1
Cp2
Compares the data in two 4-digit hexadecimal words
(Cp1 and Cp2) and outputs result to the GR, EQ, or LE
Flags.
CPS(--)
Cp1
Cp2
Compares two 16-bit (4-digit) signed binary values and
outputs the result to the GR, EQ, and LE flags.
CMPL(60)
S1
S2
Compares the 8-digit hexadecimal values in words
S1+1 and S1 with the values in S2+1 and S2, and
indicates the result using the Greater Than, Less Than,
and Equal Flags.
CPSL(--)
Cp1
Cp2
Compares two 32-bit (8-digit) signed binary values and
outputs the result to the GR, EQ, and LE flags.
BCMP(68)
S
CB
Compares a 1-word binary value (S) with the 16 ranges
given in the comparison table (CB is the starting word of
the comparison block). If the value falls within any of the
ranges, the corresponding bits in the result word (R) will
be set.
R
Lower limit
S
Upper limit Result
CB
CB+1
1
CB+2
CB+3
0
CB+4
CB+5
1
CB+30
CB+31
0
Lower limit ≤ S ≤ Upper limit 1
TABLE COMPARE
(@)TCMP(85)
TCMP(85)
CD
TB
R
Compares a 4-digit hexadecimal value (CD) with values in table consisting of 16 words. If the value of CD
falls within any of the comparison ranges, corresponding bits in result word (R) are set.
R
CD
Tb
0
Tb+1
1
0
Tb+13
1: same
0: different
•
•
•
112
1
Tb+14
0
Tb+15
1
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
DATA COMPARISON INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
MULTI-WORD COMPARE
(@)MCMP(19)
FUNCTION
MCMP(19)
S1
S2
D
AREA RANGE COMPARE
ZCP(88)
DOUBLE AREA RANGE
COMPARE
ZCPL
ZCPL(--)
CD
LL
UL
•
•
•
ZCP(--)
CD
LL
UL
Compares the data within a block of 16 words of 4-digit
hexadecimal data (S1 to S1+15) with that in another
block of 16 words (S2 to S2+15) on a word-by-word basis. If the words are not the same, the bit corresponding
to different words turns ON in the result word, D.
Compares a word to a range defined by lower and upper
limits and outputs the result to the GR, EQ, and LE flags.
Compares an 8-digit value to a range defined by lower
and upper limits and outputs the result to the GR, EQ,
and LE flags.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
113
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS
SYMBOL
NAME MNEMONIC
FUNCTION
MOVE
(@)MOV(21)
MOV(21)
S
D
Transfers data from source word, (S) to destination
word (D).
MOVE NOT
(@)MVN(22)
MVN(22)
Transfers the inverse of the data in the source word (S)
to destination word (D).
S
D
BLOCK TRANSFER
(@)XFER(70)
XFER(70)
N
S
D
Moves the content of consecutive source words (S
gives the address of the starting source word) to consecutive destination words (D is the starting destination
word).
S
BLOCK SET
(@)BSET(71)
BSET(71)
S
St
E
D
S+1
D+1
S+N--1
D+N--1
Copies the content of one word or constant (S) to several consecutive words (from the starting word, St,
through to the ending word, E).
St
S
E
MOVE BIT
(@)MOVB(82)
MOVB(82)
S
Bi
D
Transfers the designated bit of the source word or constant (S) to the designated bit of the destination word
(D).
S
D
TRANSFER BITS
@XFRB(62)
MOVE DIGIT
(@)MOVD(83)
XFRB(--)
C
S
D
Copies the status of up to 255 specified source bits to
the specified destination bits.
MOVD(83)
S
Di
D
Moves hexadecimal content of up to four specified 4-bit
source digit(s) from the source word to the specified
destination digit(s).
15
00
S
D
•
•
•
114
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS (CONTINUED)
SYMBOL
NAME MNEMONIC
FUNCTION
NETWORK SEND
(@)SEND(90)
SEND(90)
S
D
C
Transfers data from n source words (S is the starting
word) to the destination words (D is the first address) in
node N of the specified network (in a SYSMAC LINK or
NET Link System).
NETWORK RECEIVE
(@)RECV(98)
RECV(98)
S
D
C
Transfers data from the source words (S is the first
word) from node N of the specified network (in a SYSMAC LINK or NET Link System) to the destination
words starting at D.
DIST(80)
S
DBs
Of
Moves one word of source data (S) to the destination
given by the destination base word (DBs) plus offset
(Of).
SINGLE WORD
DISTRIBUTE
(@)DIST(80)
S
Base (DBs)
+
Offset (OF)
(S)
DATA COLLECT
(@)COLL(81)
COLL(81)
SBs
Of
D
XDMR(--)
N
S
D
The contents of the designated number of words of the
fixed expansion DM data are read and output to the destination word on the PLC side.
Base (DBs)
+
Offset (OF)
(SBs+Of)
EXPANSION DM READ
(@)XDMR
RECEIVE
(@)RXD
RXD(--)
D
C
N
•
•
•
(DBs + Of)
Extracts data from the source word and writes it to the
destination word (D).
(D)
Receives data via a communications port.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
115
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS (CONTINUED)
SYMBOL
NAME MNEMONIC
TRANSMIT
(@)TXD
TXD(--)
S
C
N
EM CONSTANT BLOCK
TRANSFER
(@)XFR2
XFR2
W
S
N
EM CONSTANT INTERBANK
BLOCK TRANSFER
(@)BXF2
SETUP CHANGE
(@)STUP
EXPANSION DM BANK
CHANGE
(@)EMBC
EMBC
N
INDIRECT EXPANSION DM
SETTING
(@)IEMS
IEMS
C
•
•
116
BXF2
C
S
D
STUP
N
S
•
FUNCTION
Sends data via a communications port.
Sends data of more than one word existing in series
from the designated word to the words following the
designated word. When a constant is designated where
the data is sent to or sent from, the EM area is designated.
Sends data of more than one word existing in series
from the designated word to the words following the
designated word. If the designated word is in an EM
area, the bank number can be specified.
Sends the designated word content (for 5 words) to the
system setting area of designated RS-232 port.
Changes the current bank of the Expansion DM.
Switches the indirect execution area between DM and
EM. Current bank can be switched when changing to
EM.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
LOGIC INSTRUCTIONS
SYMBOL
NAME MNEMONIC
FUNCTION
LOGICAL AND
(@)ANDW(34)
ANDW(34)
I1
I2
R
Logically ANDs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) if the corresponding
bits in the input words are both ON.
LOGICAL OR
(@)ORW(35)
ORW(35)
I1
Logically ORs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) when one or both of
the corresponding bits in the input words is/are ON.
I2
R
EXCLUSIVE OR
(@)XORW(36)
XORW(36)
I1
I2
R
Exclusively ORs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) when the corresponding bits in input words differ in status.
EXCLUSIVE NOR
(@)XNRW(37)
XNRW(37)
I1
Exclusively NORs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) when the corresponding bits in both input words have the same status.
I2
R
COMPLEMENT
(@)COM(29)
COM(29)
Wd
Inverts bit status of one word (Wd) of data, changing 0s
to 1s, and vice versa.
Wd
•
•
•
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
117
PROGRAMMING INSTRUCTIONS
SYSTEM PROCESSING INSTRUCTIONS
NAME MNEMONIC
SYMBOL
FAL(06)
N
Assigns a failure alarm code to the given execution
condition. This code is generated as an error code
whenever the instruction is executed.
SEVERE FAILURE ALARM
FALS(07)
FALS(07)
N
A fatal version of FAL(06). When a FALS(07) instruction
is executed the CPU is stopped and the number is generated as an error code.
CYCLE TIME
(@)SCAN(18)
SCAN(18)
Mi
TERM(48)
WDT(94)
T
Sets the maximum and minimum limits for the watchdog
timer (normally 0 to 130 ms). New limits:
Maximum time = 130 + (100 x T)
Minimum time = 130 + (100 x (T--1))
I/O REFRESH
(@)IORF(97)
IORF(97)
St
E
Can refresh I/O words allocated to CPU or Expansion
I/O Racks and Special I/O Modules.
GROUP-2 HIGH-DENSITY I/O
REFRESH
(@)MPRF(61)
MPRF(61)
St
E
Refreshes I/O words allocated to Group-2 High-density
I/O Modules.
INTELLIGENT IO READ
(@)IORD
IORD
C
S
D
INTELLIGENT IO WRITE
(@)IORW
IOWR
C
S
D
PROTOCOL MACRO
(@)PMCR
PMCR
C
S
D
CARD MACRO
(@)CMCR
CMCR
C
S
D
118
Shifts the Programming Console to TERMINAL mode.
----------------
WATCHDOG TIMER
REFRESH
(@)WDT(94)
•
•
Sets the minimum cycle time, Mi, in tenths of milliseconds. The possible setting range is from 0 to 999.0 ms.
-----------
TERMINAL MODE
(@)TERM(48)
•
FUNCTION
FAILURE ALARM
(@)FAL(06)
Reads data of more than one word from an ASCII
Module, etc.
Writes data of more than one word from a PLC’s CPU
to an ASCII Module.
By calling the send/receive sequence (protocol data)
registered in the Communication Board connected to a
PLC’s CPU, data can be sent to or received from
another personal computer that has RS-232C.
Reads or writes files in the memory card of the PC Card
Module.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
STEP LADDER INSTRUCTIONS
NAME MNEMONIC
•
•
•
SYMBOL
FUNCTION
STEP DEFINE
STEP(08)
STEP(08)
B When used with a control bit (B), defines the start of a
STEP START
SNXT(09)
SNXT(09)
B
new step and resets the previous step. When used without B, it defines the end of step execution.
Used with a control bit (B) to indicate the end of the step,
reset the step, and start the next step which has been
defined with the same control bit.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
119
PROGRAMMING INSTRUCTIONS
BINARY ARITHMETIC INSTRUCTIONS
NAME MNEMONIC
SYMBOL
BINARY ADD
(@)ADB(50)
ADB(50)
Au
Ad
R
FUNCTION
Adds the 4-digit augend (Au), 4-digit addend (Ad), and
content of CY and outputs the result to the specified result word (R).
Au
+
Ad
+
CY
R
CY
DOUBLE BINARY ADD
(@)ADBL
ADBL(--)
Au
Ad
R
Adds two 8-digit binary values (normal or signed data)
and contents of carry, and outputs the result to R and
R+1.
CY
BINARY SUBTRACT
(@)SBB(51)
SBB(51)
Mi
Su
R
Au + 1
Au
Ad + 1
Ad
+
CY
R+1
R
Subtracts the 4-digit hexadecimal subtrahend (Su) and
content of carry, from the 4-digit hexadecimal minuend
(Mi), and outputs the result to the specified result word
(R).
Mi
Su
CY
R
CY
DOUBLE BINARY SUBTRACT
(@)SBBL
SBBL(--)
Mi
Su
R
Subtracts an 8-digit binary value (normal or signed
data) and contents of carry from another and outputs
the result to R and R+1.
Mi + 1
Mi
Su + 1
Su
-CY
BINARY MULTIPLY
(@)MLB(52)
MLB(52)
Md
Mr
R
CY
R+1
R
Multiplies the 4-digit hexadecimal multiplicand (Md) and
4-digit multiplier (Mr), and outputs the 8-digit hexadecimal result to the specified result words (R and R+1).
Md
X
R+1
•
•
•
120
Mr
R
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
PROGRAMMING INSTRUCTIONS
BINARY ARITHMETIC INSTRUCTIONS (CONTINUED)
NAME MNEMONIC
SYMBOL
SIGNED BINARY MULTIPLY
(@)MBS
FUNCTION
MBS(--)
Md
Mr
R
Multiplies the signed binary content of two words and
outputs the 8-digit signed binary result to R+1 and R.
MBSL(--)
Md
Mr
R
Multiplies two 32-bit (8-digit) signed binary values and
outputs the 16-digit signed binary result to R+3 through
R.
Md
Mr
X
R +1
DOUBLE SIGNED BINARY
MULTIPLY
(@)MBSL
R
X
R+3
BINARY DIVIDE
(@)DVB(53)
DVB(53)
Dd
Dr
R
R+2
Md + 1
Md
Mr + 1
Mr
R+1
R
Divides the 4-digit hexadecimal dividend (Dd) by the
4-digit divisor (Dr), and outputs result to the designated
result words ( R and R + 1).
Dd
÷
Dr
Quotient
Remainder
SIGNED BINARY DIVIDE
(@)DBS
DBS(--)
Dd
Dr
R
R
R+ 1
Divides one 16-bit signed binary value by another and
outputs the 32-bit signed binary result to R+1 and R.
Quotient
R
Dr
DOUBLE SIGNED BINARY
DIVIDE
(@)DBSL
•
•
•
DBSL(--)
Dd
Dr
R
Remainder
R+1
Dd
Divides one 32-bit signed binary value by another
and outputs the 64-bit signed binary result to R+3 to
R.
Remainder
R+3
Dr+1
Dr
R+2
Quotient
R+1
Dd+1
R
Dd
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “ ” is an expansion instruction. These instructions must be assigned function codes before they can be
used.
An instruction marked with “ ” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
121
122
STANDARD PARTS
STANDARD PARTS
123
123
CPU RACK
CPU Rack
ITEM
DESCRIPTION
C Us ((All models
CPUs
ode s are
a e provided
o ded with
clock
l k function
f
ti and
d slots
l t for
f communications except CPU11-E.)
CPU11-E )
UM
DM
I/O points
RS-232C
3.2K words
4K words
640
No
C200HE-CPU11-E
7.2K words
6K words
880
No
C200HE-CPU32-E
8K words
Yes
C200HE-CPU42-E
12K words
No
C200HG-CPU33-E
Yes
C200HG-CPU43-E
No
C200HG-CPU53-E
Yes
C200HG-CPU63-E
No
C200HX-CPU34-E
Yes
C200HX-CPU44-E
No
C200HX-CPU54-E
Yes
C200HX-CPU64-E
15.2K words
PART NUMBER
1,184
31.2K words
24K words
880
1,184
Power Supply Modules
CPU I/O Backplanes
Communication Boards
STANDARDS
U, C, N, CE
100 to 120/200 to 240 VAC
C200HW-PA204
100 to 120/200 to 240 VAC (with 24-VDC output terminals)
C200HW-PA204S
24 VDC
C200HW-PD024
3 slots
C200HW-BC031
5 slots
C200HW-BC051
8 slots
C200HW-BC081
10 slots
C200HW-BC101
Communications port for SYSMAC LINK and
SYSMAC NET Link Modules
C200HW-COM01
RS-232C port
C200HW-COM02
RS-422/485 port
C200HW-COM03
Communications port for the SYSMAC LINK Module and SYSMAC C200HW-COM04-E
NET Link Module and a protocol macro function
Memory
y Cassettes
Two RS-232C ports and a protocol macro function
C200HW-COM05-E
RS-422/485 port, an RS-232C port, and a protocol macro function
C200HW-COM06-E
EEPROM
4K words
C200HW-ME04K
8K words
C200HW-ME08K
16K words
C200HW-ME16K
N
32K words
C200HW-ME32K
N, CE
16K words/32K words
C200HS-MP16K
L, CE
Equivalent to 27256, 150 ns, 12.5 V
ROM-JD-B
CE
Equivalent to 27512, 150 ns, 12.5 V
ROM-KD-B
EPROM
124
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
N, CE
EXPANSION
Expansion Rack
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
Power Supply Modules
100 to 120/200 to 240 VAC
C200HW-PA204
U, C, N, CE
100 to 120/200 to 240 VAC (with 24-VDC output terminals)
C200HW-PA204S
24 VDC
C200HW-PD024
3 slots
C200HW-BI031
5 slots
C200HW-BI051
8 slots
C200HW-BI081
10 slots
C200HW-BI0101
Expansion I/O Backplanes
I/O
Connecting
Cables
/O Co
ec g Cab
es
30 cm
70 cm
The
e total
o a length
e g of
o the
e I/O
/O Connecting
Co ec g Cables
Cab es
used
d in
i a network
t
k mustt b
be 12 m maximum.
i
---
C200H-CN311
C200H-CN711
200 cm
C200H-CN221
500 cm
C200H-CN521
1,000 cm
C200H-CN131
Slave Rack
Slave Racks Remote I/O Slave
Modules
100 to 120/200 to 240 VAC (switchable)
APF/
PCF
C200H-RT001-P
U, C, N, L
C200H-RT002-P
N, L
C200H-RT201
U, C, N, L
C200H-RT201-C
CE
24 VDC
C200H-RT202
N, L, CE
3 slots
C200H-BC031-V2
U, C, N, L,
CE
5 slots
C200H-BC081-V2
8 slots
C200H-BC051-V2
10 slots
C200H-BC101-V2
24 VDC
100 to 120/200 to 240 VAC (switchable)
Backplanes
I/O Blocks
I/O
/O
T
Terminals
i l
Link Adapter
Input
Wired
Specify either 12 or 24 VDC.
U, C, N, L
G71-IC16
Output
G71-OD16
AC input
Specify either 100 or 200 VAC.
G7TC-IA16
DC input
Specify either 12 or 24 VDC.
G7TC-ID16
Output
Specify either 12 or 24 VDC.
G7TC-OC16
O/E converter; 1 connector for RS-485, 1 connector each for APF/
PCF
B500-AL007-P
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
125
I/O MODULES
ITEM
DESCRIPTION
Input
Modules
AC Input Modules
100 to 120 VAC
C200H-IA121
U, C, N, L
16 pts
100 to 120 VAC
C200H-IA122
U, C, N, L
8 pts
200 to 240 VAC
C200H-IA221
U, C, N, L
16 pts
200 to 240 VAC
C200H-IA222
8 pts
12 to 24 VDC
C200H-ID211
16 pts
24 VDC
C200H-ID212
8 pts
12 to 24 VAC/DC
C200H-IM211
16 pts
24 VAC/DC
C200H-IM212
Interrupt Input Module
(see note)
8 pts
12 to 24 VDC
C200HS-INT01
U, C
Relay Output Modules
8 pts
2 A, 250 VAC/24 VDC (for resistive load)
C200H-OC221
U, C, N, L
12 pts
2 A, 250 VAC/24 VDC (for resistive load)
C200H-OC222
5 pts
2 A, 250 VAC/24 VDC (for resistive load)
Independent commons
C200H-OC223
8 pts
2 A, 250 VAC/24 VDC (for resistive load)
Independent commons
C200H-OC224
16 pts
2 A, 250 VAC/24 VDC (for resistive load)
(see note)
C200H-OC225
8 pts
1 A, 120 VAC
C200H-OA121-E
U, C
8 pts
1 A, 200 VAC
C200H-OA223
N, L, CE
12 pts
0.3 A, 200 VAC
C200H-OA222V
CE
8 pts
1 A, 12 to 48 VDC
C200H-OD411
U, C, N, L, CE
12 pts
0.3 A, 24 VDC
C200H-OD211
16 pts
0.3 A, 24 VDC (see note)
C200H-OD212
8 pts
2.1 A, 24 VDC
C200H-OD213
8 pts
0.8 A, 24 VDC; source type (PNP); w/load short
protection
C200H-OD214
8 pts
0.3 A, 5 to 24 VDC; source type (PNP)
C200H-OD216
12 pts
0.3 A, 5 to 24 VDC; source type (PNP)
C200H-OD217
16 pts
1 A, 24 VDC; source type (PNP); w/load short
protection
C200H-OD21A
CE
4 timers
0.1 to 1 s/1 to 10 s/10 to 60 s/1 min to 10 min
(switchable)
C200H-TM001
U, C
Connector w/lead wire (2 m) for 1 external resistor
C4K-CN223
---
15 or 16
input pts
Connects to B7A Link Terminals. Standard transmission delay.
C200H-B7AI1
U, C, CE
16 output
pts
Connects to B7A Link Terminals. Standard transmission delay.
C200H-B7AO1
(see note)
AC/DC Input Modules
Triac Output Modules
Transistor Output
Modules
Analog Timer Module
Variable Resistor
Connector
B7A Interface Modules
Note:
126
STANDARDS
8 pts
DC Input Modules
Output
Modules
PART NUMBER
U, C, N, L, CE
U, C, N, L
If the Interrupt Input Module is mounted on an Expansion I/O Rack, the interrupt function cannot be used and the Interrupt Input Module will be
treated as an ordinary 8-point Input Module. Moreover, Interrupt Input Modules cannot be used on Slave Racks.
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
SPECIAL I/O MODULES (INCLUDING GROUP 2 I/O)
Group-2 I/O Modules
ITEM
DESCRIPTION
DC Input Modules
32 pts
24 VDC
64 pts
Transistor Output
Modules
B7A Interface Modules
(GROUP 2 I/O MODULES)
32 pts
32 output pts
STANDARDS
C200H-ID216
U, C, N, L,
CE
C200H-ID217
16 mA at 4.5 V to 100 mA at 26.4 V
64 pts
32 input pts
PART NUMBER
U, C, N, L
C200H-OD218
C200H-OD219
Connects to B7A Link Terminals. Standard
or high-speed
hi h
d transmission
t
i i delay.
d l
---
C200H-B7A12
C200H-B7A02
16 input and 16
output points
C200H-B7A21
32 input and 32
output points
C200H-B7A22
DESCRIPTION
PART NUMBER
STANDARDS
U,, C,, N,, L,,
CE
Special I/O Modules
ITEM
High-density
g
y
I/O M
Modules
d l
(see note 1)
DC Input Modules
Transistor Output
Modules
DC Input/Transistor
Output Modules
Analog I/O
Modules
Analog Input
Modules
Analog Output
Modules
Fuzzy Logic Module
Fuzzy Support
Software
Temperature Sensor Module
32 pts
5 VDC (TTL inputs); w/high-speed input
C200H-ID501
32 pts
24 VDC; w/high-speed input
C200H-ID215
32 pts
0.1 A, 24 VDC (useable as 128-point dynamic
output unit)
C200H-OD215
32 pts
35 mA, 5 VDC (TTL outputs) (useable as
128-point dynamic output unit)
C200H-OD501
16 input and
16 output pts
24-VDC inputs; w/high-speed input; 0.1-A,
24-VDC outputs (useable as 128-point dynamic
input unit)
C200H-MD215
16 input and
16 output pts
5-VDC TTL inputs; w/high speed input; 35-mA,
5-VDC TTL outputs (useable as 128-point dynamic input unit)
C200H-MD501
16 input and
16 output pts
12-VDC TTL inputs; w/high speed input;
12-VDC TTL outputs (useable as 128-point dynamic input unit)
C200H-MD115
N, L
4 to 20 mA, 1 to 5/0 to 10 V (switchable); 4 inputs; 12 bits
C200H-AD001
U, C, N, L
4 to 20 mA, 1 to 5/0 to 10 V/--10 to 10V (switchable); 8 inputs; 12
bits or BCD
C200H-AD002
4 to 20 mA, 1 to 5/0 to 10 V (switchable); 2 outputs
C200H-DA001
4 to 20 mA, --10 to 10 V; 4 outputs
C200H--DA002
---
Programmed using the Fuzzy Support Software.
C200H-FZ001
N
Available on either 3.5” or 5.25” floppy disks.
C500-SU981-E
---
Thermocouple
K(CA) or J(IC), switchable; 4 inputs
C200H-TS001
U, C
K(CA) or L(Fe-CuNi) DIN standards; 4 inputs
C200H-TS002
Pt 100 Ω; 4 inputs
C200H-TS101
Pt 100 Ω; 4 inputs; DIN and 1989 JIS standards
C200H-TS102
Pt resistance
thermometer
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
127
SPECIAL I/O (CONTINUED)
ITEM
DESCRIPTION
Temperature Control Modules
Thermocouple
Pt resistance
thermometer
Heat/Cool
Temperat re Control Mod
Temperature
Modules
les
Thermocouple
Pt resistance
thermometer
Cam Positioner Module
PART NUMBER
STANDARDS
Transistor output
C200H-TC001
U, C
Voltage output
C200H-TC002
Current output
C200H-TC003
Transistor output
C200H-TC101
Voltage output
C200H-TC102
Current output
C200H-TC103
Transistor output
C200H-TV001
Voltage output
C200H-TV002
Current output
C200H-TV003
Transistor output
C200H-TV101
Voltage output
C200H-TV102
Current output
C200H-TV103
Detects angles of rotation by means of a resolver and provides ON and OFF outputs at specified angles. A maximum of
C200H-CP114
48 cam outputs (16 external outputs and 32 internal outputs) maximum are available.
Data Setting Console
Connecting
g Cables
PID Control Modules
Position Control Modules
High-speed Counter Modules
ASCII/BASIC Modules
128
Used to set and monitor data in Temperature Control Modules and C200H-DSC01
Cam Positioner Modules.
2m
C200H-CN225
4m
C200H-CN425
Transistor output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable)
C200H-PID01
Voltage output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable)
C200H-PID02
Current output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable)
C200H-PID03
1 axis
Pulse output; directly connects to servomotor
driver; compatible with line driver; speeds: 1 to
250,000 pps
C200H-NC112
U, C, CE
2 axis
Pulse output; speeds: 1 to 250,000 pps, 53 pts
per axis
C200H-NC211
U, C
1 axis
Pulse input; counting speed: 50 kcps; 5
VDC/12 VDC/24 VDC
C200H-CT001-V1
U, C, CE
1 axis
Pulse input; counting speed: 75 kcps; RS-422
line driver
C200H-CT002
2 axis
Pulse input; counting speed: 75 kcps; RS-422
line driver
C200H-CT021
24K-byte RAM and 24K-byte EEPROM are built-in.
C200H-ASC02
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
--U, C
CE
SPECIAL I/O (CONTINUED)
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
RFID Sensor Modules
Local application, electromagnetic coupling
C200H-IDS01-V1
U, C
Remote application; microwave transmissions
C200H-IDS21
---
Electromagnetic type
V600-H series
Microwave type
V620-H series
SRAM type for V600-H series.
V600-D
Read/Write Heads
Data Carriers
Voice Module
Connecting Cable
Motion Control Module
60 messages max.; message length: 32, 48, or 64 s (switchable)
C200H-OV001
RS-232C
C200H-CN224
G-language programmable 2-axis analog outputs
C200H-MC221
MC Support Software
IBM PC/AT or compatible
CV500-ZN3AT1-E
Connecting cable
3.3 m
CQM1-CIF02
Teaching Box
---
CVM1-PRS71
Connection cable for
Teaching Box
2 m long
CV500-CN224
Memory Pack
(with key sheet)
(see note 2)
---
CVM1-MP701
Terminal Block
Conversion Unit
Simplifies wiring for I/O connectors.
XW2B-20J6-6
Connecting cable for
Terminal Block Conversion Unit
Note:
EEPROM type for V600-H series.
R
V600-DP
---
XW2Z-100J-F1
1. When mounting a High-density I/O Module as a Special I/O Module to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or
C200H-RM201.
2. The CV-series Programming Console can be used as a Teaching Box by replacing the Memory Pack of the Programming Console.
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
129
I/O MODULE ACCESSORIES
ITEM
DESCRIPTION
PART NUMBER
I/O
/O Terminal
e
a BLock
oc Co
Cover
e
For 10 pin I/O Terminal Blocks
For 19 pin I/O Terminal Blocks
For 5- and 8- point Modules
24-pin, solder type, straight
24-pin, crimp type
24-pin, for ribbon cable
24-pin, solder type, 90° angle
40-pin, solder type, straight
40-pin, crimp type
40-pin, for ribbon cable
40-pin, solder type, 90° angle
RS-232C, 25 pins
RS-422, 9 pins
RS-232C, 25 pins
RS-422, 9 pins
C200H-COV02
C200H-COV03
C200H-COV11
C500-CE241
C500-CE242
C500-CE243
C500-CE244
C500-CE401
C500-CE402
C500-CE403
C500-CE404
0020756-4, RS-232 connector
0020757-2, RS-422 connector
0020758-0, RS-232 cover
0020759-9, RS-422 cover
Connector
Co
ec o
Connector Cover
130
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
COMMUNICATION MODULES
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
PC Card Module
A memory card suitable for Phoenix PCM+3.2 and one of the following
Bus Connection Units is required. No PC card is provided with the module.
C200HW-PCU01-E
---
Ethernet Set
A floppy disk containing Ethernet setup utility data is provided. One of
the following Bus Connection Units is required. No PC card is provided
with the Module.
C200HW-PCS01-E
Bus Connection
Units
For 1 Module
C200HW-CE011
For 2 Modules
C200HW-CE012
SYSMAC LINK Module
(coaxial cable)
A Bus Connection Unit must be ordered separately.
y
Data link table:
918 words
C200HW-SLK23
Data link table:
2,966 words
C200HW-SLK24
Terminator
One required for each node at ends of System.
C1000H-TER01
Attachment
Stirrup
Provided with SYSMAC LINK Module.
C200H-TL001
F Adapter
To connect network
C1000H-CE001
F Adapter Cover
To connect network
SYSMAC LINK Module
(fiber-optic cable)
U, C, N
---
C1000H-COV01
Connect with H-PCF cable. A Bus Connection
y
Unit must be ordered separately.
Data link table:
918 words
C200HW-SLK13
Data link table:
2,966 words
C200HW-SLK14
U, C, N
Power Supply
Adapter
Required when supplying backup power
For 1 or 2
Modules
C200H-APS03
U, C
Power Cable
Connects Power Supply
y Adapter and SYSMAC NET
Li k Module.
Link
M d l
For 1 Module
C200H-CN111
---
For 2 Modules
C200H-CN211
SYSMAC LINK Support
Board (coaxial cable)
To connect IBM PC/AT or compatible as node in SYSMAC LINK system
3G8F5-SLK21-E
SYSMAC NET LINK
Module
A Bus Connection Unit must be ordered separately.
C200HS-SNT32
Power
o e Su
Supply
y
Ad t
Adapter
Required
equ ed when
e su
supplying
y g backup
bac u power
o e
Power Cable
Connects Power Supply Adapter
and SYSMAC NET Link Module.
Bus Connection Units
Host Link Modules
DeviceNet Scanner Module
For 1 Module
C200H-APS01
For 2 Modules
C200H-APS02
Included with
C200H-APS01
For 1 Module
C200H-CN001
Included with
C200H-APS02
For 2 Modules
C200H-CN002
For 1 Module
C200HW-CE001
For 2 Modules
C200HW-CE002
APF/PCF
C200H-LK101-PV1
N, L
RS-422
C200H-LK202-V1
U, C
RS-232C
C200H-LK201-V1
Connects SYSMAC LINK Module or SYSMAC NET
Link Module to CPU.
Rack-mounting
Number of I/O points: 1,600 max.
Number of Slave Modules: 50 max.
C200H, C200HS,
C200HE,
C200HG,
C200HX
C200HW-DRM21
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
131
N
U, C, N
COMMUNICATION MODULES AND SYSMAC NET/SYSMAC LINK
ITEM
DESCRIPTION
PC Link
Module
Remote I/O Master
Modules
Remote I/O Slave Modules
Note:
PART NUMBER
STANDARDS
Single level: 32 Modules
Multilevel: 16 Modules
RS-485
C200H-LK401
N, L
Up to two per PLC; connectable to up to 5 Slaves per
PLC total
APF/PCF
C200H-RM001-PV1
Wired
C200H-RM201
For reference, see Slave Racks on page 125 (also page 84).
Only a single PC Card Module can used with the CPU.
SYSMAC NET/SYSMAC LINK Hardware
132
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
SYSMAC NET Network Support
Board
For IBM PC/AT or compatible
S3200-NSB11-E
---
SYSMAC LINK Network Support
Board
For IBM PC/AT or compatible, coaxial cable connector
3G8F5-SLK21-E
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
FIBER-OPTIC COMMUNICATION MODULE CONNECTIONS
3GS3200 Connectors (S3200 is the Part No. prefix.)
C200H
C1000H, C2000H
CVM1, CV500, CV1000, CV2000
SYSMAC NET Network Support
Board
SYSMAC NET Line Server
SYSMAC NET Bridge
SYSMAC NET Network Service
Unit
SYSMAC NET VME Interface
SYSMAC NET
SYSMAC LINK
SYSMAC WAY
SYSMAC BUS
COCH82
COCH82
COCF2011
—
SYSMAC
BUS/2
—
—
COCF2011
—
COCF2511
COCH62M
COCF2011
COCH62M
COCF2511
COCF2011
COCF2011
—
COCH62M
COCH62M
COCH62M
—
—
—
—
—
—
—
—
—
—
—
—
COCH62M
—
—
—
—
COCH82
COCH82
COCF2011
—
3G5A2 Connectors (-P modules only) 3G5A2 is the Part No. prefix. B500 Part No. prefixes are equivalent to 3G5A2 prefixes.
C200H
C1000H, C2000H
CVM1, CV500, CV1000, CV2000
SYSMAC WAY
CO001, CO002
CO001, CO002
—
SYSMAC BUS
CO001, CO002
CO001, CO002
CO001, CO002
All Plastic Fiber-optic (APF) Cable
ITEM
DESCRIPTION
PART NUMBER
Fiber-optic Cable
Fiber-optic
be o c
Connectors
20 m (65.6 ft.), without connectors
Brown, for cable 0 to 10 m (0 to 32.8 ft.) long (includes 2)
Black, for cable 8 to 20 m (0 to 65.6 ft.) long (includes 2)
B500-PF212
3G5A2-CO001
3G5A2-CO002
Hard Plastic-Clad Fiber-optic (HPCF) Cable
ITEM
DESCRIPTION
PART NUMBER
Fiber-optic
be o c
C bl
Cable
50 m (164 ft.), without connectors
100 m (328 ft.), without connectors
500 m (0.31 mile), without connectors
1 km (0.62 mile), without connectors
Zipcord style, orange, 50 m (164 ft.), without connectors
SYSMAC BUS or SYSMAC WAY only
SYSMAC BUS/2 (all PLCs), SYSMAC LINK (other than C200H)
SYSMAC NET (other than C200H)
SYSMAC NET, LINK (C200H only)
SYSMAC NET In-line male connector
SYSMAC NET In-line female connector
SYSMAC LINK In-line adapter
For HPCF Cable
FCS-HCR-LB-501
FCS-HCR-LB-102
FCS-HCR-LB-502
FCS-HCR-LB-103
FCS-HCR-CO-501
S3200-COCH82
S3200-COCF2011
S3200-COCH62M
S3200-COCF2511
S3200-COCF62M
S3200-COCF62F
S3200-COIAT2000
FCS-CAK6230-US
Fiber-optic
be o c
C
Connectors
t
In-line
e Fiber-optic
be o c
C
Connectors
t
Termination Kit
Plastic-Clad Fiber-optic (PCF) Cable
ITEM
DESCRIPTION
PART NUMBER
Indoor Fiber-optic
C bl
Cable
10 cm (0.32 ft.), with connectors
1 m (3.2 ft.), with connectors
2 m (6.56 ft.), with connectors
3 m (9.8 ft.), with connectors
5 m (16.4 ft.), with connectors
10 m (32.8 ft.), with connectors
20 m (65.6 ft.), with connectors
30 m (98 ft.), with connectors
50 m (164 ft.), with connectors
100 m (328 ft.), with connectors
200 m (656 ft.), with connectors
400 m (0.25 mile), with connectors
800 m (0.5 mile), with connectors
3G5A2-OF011
3G5A2-OF101
3G5A2-OF201
3G5A2-OF301
3G5A2-OF501
3G5A2-OF111
3G5A2-OF211
3G5A2-OF311
3G5A2-OF511
3G5A2-OF002-100M
3G5A2-OF002-200M
3G5A2-OF002-400M
3G5A2-OF002-800M
Indoor/Outdoor
doo /Ou doo
Fib
Fiber-optic
ti Cable
C bl
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
133
LINK ADAPTERS
134
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
Link Adapters
3 RS-422 connectors
3G2A9-AL001
N, L
3 fiber-optic connectors (APF/PCF)
3G2A9-AL002-PE
N
3 fiber-optic connectors (PCF)
3G2A9-AL002-E
1 connector for RS-232C; 2 for RS-422
3G2A9-AL003
---
1 connector each for APF/PCF, RS-422, and RS-232C
3G2A9-AL004-PE
N, L
1 connector each for PCF, RS-422, and RS-232C
3G2A9-AL004-E
1 connector each for APF/PCF and APF
3G2A9-AL005-PE
1 connector each for PCF and AGF
3G2A9-AL005-E
1 connector for APF/PCF; 2 for AGF
3G2A9-AL006-PE
1 connector for PCF; 2 for AGF
3G2A9-AL006-E
O/E converter; 1 connector for RS-485, 1 connector each for
APF/PCF
B500-AL007-P
N, L
Used for on-line removal of SYSMAC NET Link Units from
the SYSMAC NET Link System, SYSMAC NET Fiber-optic
Link Adapter (3 connectors for APF/PCF)
B700-AL001
---
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
---
PROGRAMMING DEVICES
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
Programming Consoles
Provided with a 2-m cable for ladder programming
C200H-PRO27-E
U, C
One of the following connection cables is required for ladder programming.
CQM1-PRO01-E
Programming Console
Mounting Bracket
Used to attach Hand-held Programming Console to a
panel.
C200H-ATT01
Programming Console
Connecting Cables
For C200H-PRO27-E Hand-held
Programming Console
2m
4m
C200H-CN222
C200HS-CN222
CE
C200H-CN422
---
C200HS-CN422
CE
---
Data Setting Console
Used for data input and process value display for the
C200H-TC
.
C200H-DSC01
Data Setting Console
Connecting Cables
For C200H-DSC01
2m
C200H-CN225
4m
C200H-CN425
3.3 m
CQM1-CIF02
Connecting Cable
Used to connect an IBM PC/AT or
compatible to the C200HX/HG/HE.
---
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
135
OPTIONAL PRODUCTS
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
I/O Module
Cover
Cover for 10-pin terminal block
C200H-COV11
---
Terminal Block Covers
Short protection for 10-pin terminal block (package of 10 covers); 8 pts
C200H-COV02
Short protection for 19-pin terminal block (package of 10 covers); 12 pts
C200H-COV03
Connector Cover
Protective cover for unused I/O Connecting Cable connectors
C500-COV02
Space Module
Used for vacant slots
C200H-SP001
N, L
Battery Set
For C200H or C200HS RAM Memory Unit only
C200H-BAT09
---
Relay
24 VDC
G6B-1174P-FD-US
CPU Backplane
Insulation Plates
For 3-slot Backplane
C200H-ATT31
For 5-slot Backplane
C200H-ATT51
For 8-slot Backplane
C200H-ATT81
For 10-slot Backplane
C200H-ATTA1
For 3-slot Backplane
C200HW-ATT32
For 5-slot Backplane
C200HW-ATT52
For 8-slot Backplane
C200HW-ATT82
For 10-slot Backplane
C200HW-ATTA2
Solder terminal; 40p and a Connector Cover
C500-CE401
Solderless terminal; 40p and a Connector Cover (Crimp-type)
C500-CE402
Pressure welded terminal; 40p
C500-CE403
Solder terminal; 40p and a Connector Cover (Horizontal-type)
C500-CE404
Crimp-style terminal; 40p and a Connector Cover (Horizontal-type)
C500-CE405
I/O Backplane
Insulation Plates
External Connectors
136
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
---
N
---
MOUNTING RAIL AND MOUNTING ACCESSORIES
ITEM
DESCRIPTION
PART NUMBER
STANDARDS
DIN Rail Mounting
Bracket
1 set (2 included)
C200H-DIN01
---
DIN Rails
Length: 50 cm; height: 7.3 cm
PFP-50N
Length: 1 m; height: 7.3 cm
PFP-100N
Length: 1 m; height: 16 mm
PFP-100N2
End Plate
---
PFP-M
Spacer
---
PFP-S
Note:
Order DIN Rails, End Plates, and Spacers in units of 10 each.
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
137
SOFTWARE
SYSMAC Support Software (SSS)
ITEM
DESCRIPTION
PART NUMBER
SYSMAC Support Software
(for C20, C
P, C
K,
C120, C
H, C200H,
C200HS, C200HE, C200HG,
C200HX, C500, C1000H,
C2000H, CQM1, and CVM1)
3.5”, 2HD for IBM PC/AT compatible
C500-ZL3AT1-EV1.2
DESCRIPTION
PART NUMBER
3.5”, 2HD for IBM PC/AT compatible
SYSWINHL-V3.0
ITEM
DESCRIPTION
PART NUMBER
Protocol Support Software
3.5”, 2HD for IBM PC/AT compatible
C200HW-ZW3AT1-E
SYSWIN
ITEM
SYSWIN
(for C20, C
P, C
K,
C120, C
H, C200H,
C200HS, C200HE,
C200HG, C200HX, C500,
C1000H, C2000H, CQM1,
and CVM1)
Protocol Support Software (PSS)
Motion Control Support Software (MCSS) -- for C200H-MC221 Motion Control Module ONLY
138
ITEM
DESCRIPTION
PART NUMBER
Motion Control
Support Software
3.5”, 2HD for IBM PC/AT compatible
CV500-ZN3AT1-E
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
MANUALS
PLC Installation, Operation
ITEM
DESCRIPTION
PART NUMBER
C200HX/C200HG/C200HE PLCs
C200HX/C200HG/C200HE PLCs
C200HW-COM01-C200HW-COM06-E
C200HW-ZW3AT1-E Protocol
Software
Installation Guide
Operation Guide
Operation Guide
Operation Guide
W302
W303
W304
W305
ITEM
DESCRIPTION
PART NUMBER
C200H-PCU01/PCS01
C200H-ASC02
C200H-AD001, C200H-DA001
C200H-AD002
C200H-DA002
C200H-CT001-V1/CT002
C200H-CT021
C200H-TS001/TS002
C200H-TC
PC Card Module
ASCII/BASIC Module
Analog I/O Modules
Analog Input Module
Analog Output Module
High-speed Counter Modules
High-speed Counter Modules
Temperature Sensor Input Modules
Temperature Control Module
W313
W165
W127
W229
W260
W141
W311
W124
W225
C200H-TV
Heat/Cool Temperature Control Module
W240
PID Control Module
W241
Cam Positioner Module
Position Control Module
Position Control Module
Position Control Module
ID Sensor Module
Voice Module
Motion Module
Fuzzy Logic Module
W224
W137
W128
W166
W153
W172
W314 / W315 / W256
W208
DESCRIPTION
PART NUMBER
SYSMAC Link Modules
SYSMAC Net Module
PC Link Module
Host Link Modules
System manual
System manual
System manual
W174
W114
W135
W143
W120
W136
W267
DESCRIPTION
PART NUMBER
Operation manual
W173
W84
Operation manual
Operation manual
Procedures for programming EPROM
Procedures for interfacing with floppy disk
W150
W107
W155
W119
ITEM
DESCRIPTION
PART NUMBER
SYSMAC Support Software
SYSWIN Support Software
Programming procedures using SSS
Programming procedures using SYSWIN
W247/W248
SYSWIN-EMAN-V
Special I/O Modules
C200H-PID
C200H-CP114
C200H-NC111
C200H-NC112
C200H-NC221
C200H-IDS01/IDS21
C200H-OV001
C200H-MC221
C200H-FZ001
Communications
ITEM
C200HW-SLK
C200HS-SNT32
C200H-LK401
C200H-LK20
SYSBUS Wired Remote I/O
SYSBUS Fiber-Optic Remote I/O
DeviceNet
Peripheral Devices
ITEM
C200H-DAC01
GPC (Graphics Programming
Console)
FIT (Factory Intelligent Terminal)
Printer Interface Module
PROM Writer Operation Guide
Floppy Disk Interface Module
Programming Software
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
139
140
COMPLEMENTARY PRODUCTS
COMPLEMENTARY
141
PRODUCTS
Operator Interface Terminals
142
141
COMPLEMENTARY PRODUCTS
OPERATOR INTERFACE TERMINALS
Easy to order, with no complicated configuration (communications and memory are built-in), the NT Series Terminals
provide a variety of control options. From the basic 4 line x 20 character, text-based NT11S to our graphic touch screen
models — including the slim NT20S (with a depth of only 54 mm) and the eight-color NT620C — our new line of terminals can be relied on for clear, dependable data presentation. And with Omron’s Host Link and NT Link communication
methods, fast response times between terminal and PLC are guaranteed. Direct connection to the C200H backplane is
also available on some models for an even faster response. Combine this with Omron’s NT Support Software and you
get a powerful operator interface that’s easy to read and quick to connect with screens that are simple to create.
MODEL
NT11S
NT20S
NT30
NT30C
DISPLAY
Size
4 line x 20 character
5" diagonal
5.7" diagonal
5.7" diagonal
Type
Backlit LCD
Backlit STN LCD
Bicolor backlit STN LCD
8-color backlit STN LCD
Resolution
160 x 64 pixels
256 x 128 pixels
320 x 240 pixels
320 x 240 pixels
Interface
Alphanumeric
Touch screen
Touch screen
Touch screen
Touch cells
—
72 per screen
192 per screen
192 per screen
Large characters
Slim profile
Bicolor display
8-color display
Contrast control
Easy to configure screens
Full graphic capabilities
Full graphic capabilities
Password protect screens
Replaceable backlight
Replaceable backlight
Replaceable backlight
Type
Flash EPROM
Flash EPROM
Flash EPROM
Flash EPROM
Size
32 K
64-92 K
512 K
512 K
250 screens
250 screens
2000 screens
2000 screens
Communication
Host Link / NT Link
Host Link / NT Link /
C200H Interface
Host Link / NT Link
Host Link / NT Link
Overall
Dimensions
218W x 113H x 38.2D mm
8.58W x 4.45H x 1.50D in
190W x 110H x 58D mm
7.48W x 4.33H x 2.28D in
195W x 142H x 55.6D mm
7.68W x 5.59H x 2.19D in
195W x 142H x 55.6D mm
7.68W x 5.59H x 2.19D in
Ratings
NEMA 4
NEMA 4
NEMA 4
NEMA 4
Approvals
UL / CSA
UL / CSA
UL / CSA
UL / CSA
—
Backlight
Backlight
Backlight
Chemical resistant cover
Chemical resistant cover
Chemical resistant cover
Protective sheet
Protective sheet
Protective sheet
C200H Interface
B7A Interface
B7A Interface
FEATURES
MEMORY
Max.
# of screens
GRAPHIC CAPABILITIES
Freeform drawing
Bitmap
Tiling
Bar graph
Line trending
Thumbwheel switch
Text and numeric
Real-Time
Clock
Printer Port
ENVIRONMENTAL
Accessories
142
COMPLEMENTARY PRODUCTS
OPERATOR INTERFACE TERMINALS
MODEL
NT600S (LCD)
NT600S (EL)
NT620S
NT620C
Size
9" diagonal
9" diagonal
9" diagonal
9.7" diagonal
Type
Backlit STN LCD
Electroluminescent
Electroluminescent
8-color backlit STN LCD
Resolution
640 x 400 pixels
640 x 400 pixels
640 x 400 pixels
640 x 480 pixels
Interface
Touch screen
Touch screen
Touch screen
Touch screen
Touch cells
128 per screen
128 per screen
512 per screen
768 per screen
Large screen
Clear EL display
Clear EL display
8-color display
Slim profile
Extra-wide viewing angle
Full graphic capabilities
Full graphic capabilities
Replaceable backlight
Slim profile
Extra-wide viewing angle
Replaceable backlight
DISPLAY
FEATURES
MEMORY
Type
Flash EPROM
Flash EPROM
Flash EPROM
Flash EPROM
Size
128 K
128 K
512 K
1 MB
500 screens
500 screens
2000 screens
2000 screens
Communication
Host Link / NT Link
C200H Interface
Host Link / NT Link /
C200H Interface
Host Link / NT Link
Host Link / NT Link
Overall
Dimensions
275W x 192H x 71D mm
10.83W x 7.56H x 2.80D in
275W x 192H x 71D mm
10.83W x 7.56H x 2.80D in
275W x 192H x 71D mm
10.83W x 7.56H x 2.80D in
275W x 196H x 76.8D mm
10.83W x 7.72H x 3.02D in
Ratings
NEMA 4
NEMA 4
NEMA 4
NEMA 4
Approvals
UL / CSA
UL / CSA
UL / CSA
UL / CSA
Accessories
Backlight
Chemical resistant cover
Chemical resistant cover
Backlight
Chemical resistant cover
Protective sheet
Protective sheet
Chemical resistant cover
Protective sheet
C200H Interface
Max.
# of screens
GRAPHIC CAPABILITIES
Freeform drawing
Bitmap
Tiling
Bar graph
Line trending
Thumbwheel switch
Text and numeric
Real-Time
Clock
Printer Port
ENVIRONMENTAL
C200H Interface
Protective sheet
143
OPERATOR INTERFACE TERMINAL
COMMUNICATIONS OPTIONS
Direct Access Function greatly reduces programming effort
of the host. The Direct Access Function enables the user to
directly access the relay area and DM area of the Host. Using
this function, the user can greatly reduce the PLC programming
effort that is required for the Operator Interface Terminals. The
C200HX/HG/HE Interface and NT Link are ideal for applications
that require high-speed input operations.
NT Link
1:1 NT Link
• Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Host
• Enables a faster I/O response by using a dedicated
communications protocol.
RS-232C port
15 m max.
Operator
Interface
Terminal
RS-422 Host Link Connection
• Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Host
• Ideal for a long-distance transmission with 1:1 connection.
Host Link
Module
RS-422 Cable
500 m max.
CPU
Operator
Interface
Terminal
RS-232C Host Link Connection
• Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Host
• One of the most popular communications systems.
Host Link
Module
Host Link Cable
Distance: 15 m max.
CPU
Operator
Interface
Terminal
C200H Backplane Connection
Host
• Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
I/O Expansion Port
• Directly connects to the I/O expansion port of the
C200HX/HG/HE to achieve faster response and high-speed
display.
I/O Expansion Cable
10 m max.
Operator
Interface
Terminal
144
• No Communications Units are required on the
C200HX/HG/HE side.
OPERATOR INTERFACE TERMINAL
COMMUNICATIONS OPTIONS
Communications Methods Applicable to C200HX/HG/HE
Possible to connect to the I/O expansion port
Possible to use from the Communications Module built
into the CPU (see note)
Possible to connect to the Communications Module
DIRECT ACCESS FUNCTION
PLC
C
RS-232C
HOST LINK
CONNECTION
C200HX/HG/HE
Note:
/
C200H
BACKPLANE
CONNECTION
NT LINK
RS-422
HOST LINK
CONNECTION
/
C200HE-CPU42-E, C200HG-CPU43-E/63-E, and C200HX-CPU44-E/64-E allow
connection to the built-in port.
Communications Methods of the NT Series
OPERATOR
O
O
INTERFACE
TERMINAL
DIRECT ACCESS FUNCTION
RS-232C
HOST LINK
CONNECTION
C200H
BACKPLANE
CONNECTION
NT LINK
RS-422
HOST LINK
CONNECTION
NT11S
Yes
---
Yes
Yes
NT20S
Yes
Yes
Yes
---
NT30/C
Yes
---
Yes
Yes
NT600S
Yes
Yes
Yes
---
NT620S/C
Yes
---
Yes
---
145
I/O BLOCKS
I/O Blocks Connect to High-density I/O Modules,
Mixed I/O Modules and Normal I/O Modules
Connecting to High-density I/O Modules
C200H-ID215
C200H-OD215
C200H-MD215
G70A I/O
Block*
G79 Connecting
Cable
G7VC Output Block
G70A I/O Blocks
• G70A I/O Blocks provide16 contact input or 16 contact output
points in a compact package (234 x 75 x 64 mm).
• They mount to DIN track to save installation and
maintenance time.
G7VC Output Blocks
• G7VC Output Blocks provide 16 output points in a compact
package (192 x 58 x 38.5 mm).
Connecting to Group-2 I/O Modules
• A rotating front cover provides easy access to terminals for
simplified maintenance and increased safety.
C200H-ID216
C200H-ID217
C200H-OD218
C200H-OD219
II
I
IV
G79-I or G79-O
Connecting
Cable
G70A I/O
Block*
III
G7VC Output Block
Note:
I to IV indicate connector numbers.
Connecting to I/O Modules Equipped with Connectors
C200H-OD215
C200H-MD215
G70A-ZOC16-3
I/O Block with Relays
G79 Connecting
Cable (1:1)
146
G72C/G72C-V I/O TERMINALS
G72C/G72C-V I/O Terminals In Remote I/O Systems
I/O Terminals are connected as Slaves in Remote I/O Systems
to provide for special wiring needs via wiring blocks.
Compactness in the right shape is provided by a choice
between flat terminals (182 x 85 x 45 mm) and vertical terminals
(202 x 45 x 63 mm).
C200H-RM201
Remote I/O Master Module
G72C-VID16
G72C-VOD16
G72C-ID16
G72C-OD16
G70A-ZOC16-3
Valve wiring block
(Not sold by OMRON.)
G71-OD16
Note:
Ask your OMRON dealer for more information concerning OMRON
I/O Blocks and I/O Terminals.
147
CONNECTOR TERMINAL CONVERSION UNITS/CABLES
Connecting Cables
A
For 32-point I/O Modules with Connectors:
XW2ZNote:
The G79- C (Cable for G7TC) cannot be used for the XW2C.
You Can Easily Convert Between Connectors and Terminal Blocks
to Simplify Control Wiring.
XW2B
• Only 45 mm wide, the XW2B connects directly to PLC I/O
• Modules using special cables to simplify connection.
• Snap onto DIN rail or mount with screws.
• Easy panel-mounting.
XW2Z
• A special cable for easy connection between PLC I/O
Modules and Connector--Terminal Conversion Units
For 32-point I/O Modules with Connectors (Group-2 Slaves) or
B
For 64-point I/O Modules with Connectors :
Connection Examples
XW2Z-
32-point PLC I/O Modules
with Connectors
XW2ZA
Connecting Cable
For 32-point Input Modules with Connectors (Group-2 Slaves) or
For 64-point Input Modules with Connectors :
D
XW2ZNote:
C200H-ID215
C200H-OD215
C200H-MD115
C200H-MD215
C200H-MD501
C200H-ID501
C200H-OD501
XW2B-20G
(Cable for G7TC) cannot be used for the XW2C.
The G79-1 C-
F
Cable with Loose Crimp Connectors (20 connections) :
32-point I/O Modules
with Connectors
(Group-2 Slaves)
64-point I/O Modules
with Connectors
(Group-2 Slaves)
C200H-ID216
C200H-OD218
C200H-ID217
C200H-OD219
XW2Z-
XW2B-40G
I/O Modules with
Terminal Blocks
XW2ZF
Cable with
Loose Crimp
Connectors
XW2B-20G
148
PART NUMBER INDEX
PART NUMBER INDEX
149
149
PART NUMBER INDEX
C200HW--COM05--E . . . . . . . . . . . . . 14, 124
C200H--TS101 . . . . . . . . . . . . . . .42, 43, 127
C200HW--COM06--E . . . . . . . . . . . . . 14, 124
C200H--TV00_ . . . . . . . . . . . . . . .46, 47, 128
C200HW--DRM21 . . . . . . . . . . . . . . . .81, 131
C200H--TV10_ . . . . . . . . . . . . . . .46, 47, 128
C200HW--ME04K . . . . . . . . . . . . . . . .17, 124
C200HIA222 . . . . . . . . . . . . . . . . . . . .23, 126
C200HW--ME08K . . . . . . . . . . . . . . . .17, 124
C200HS--CN220--EU . . . . . . . . . . . . . . . . . 98
C200HW--ME16K . . . . . . . . . . . . . . . .17, 124
G6B--1174P--FD--US . . . . . . . . . . . . . . . . 136
C200HS--CN222 . . . . . . . . . . . . . . . . . . . .135
C200HW--ME32K . . . . . . . . . . . . . . . .17, 124
G71--IC16 . . . . . . . . . . . . . . . . . . . . . . . . .125
C200HS--CN229--EU . . . . . . . . . . . . . . . . . 98
C200HW--P___ . . . . . . . . . . . . . . . . . .17, 124
G71--OD16 . . . . . . . . . . . . . . . . . . . . . . . .125
C200HS--CN422 . . . . . . . . . . . . . . . . . . . .135
C200HW--PA204. . . . . . . . . . . . .18, 124, 125
G7TC--IA16 . . . . . . . . . . . . . . . . . . . . . . . .125
C200HS--INT01 . . . . . . . . . . . . . .31, 32, 126
C200HW--PA204S . . . . . . . . . . . 18, 124, 125
G7TC--ID16 . . . . . . . . . . . . . . . . . . . . . . . .125
C200HS--MP16K . . . . . . . . . . . . . . . .17, 124
C200HW--PCS01--E . . . . . . . . 72, 73, 74, 131
G7TC--OC16 . . . . . . . . . . . . . . . . . . . . . . .125
C200HS--SNT32 . . . . . . . . . . . . . .75, 76, 131
C200HW--PCU01--E . . . . . . . . 72, 73, 74, 131
C200HW--ATT32. . . . . . . . . . . . . . . . . . . .136
C200HW--PD024 . . . . . . . . . . . .18, 124, 125
C200HW--ATT52. . . . . . . . . . . . . . . . . . . .136
C200HW--SLK13/14 . . . . . . . . 78, 79, 80, 131
PFP--100N . . . . . . . . . . . . . . . . . . . . . . . . .137
C200HW--SLK23/24 . . . . . . . . 78, 79, 80, 131
PFP--100N2 . . . . . . . . . . . . . . . . . . . . . . . .137
C200HW--ZW3AT1--E . . . . . . . . . . . . . . . 138
PFP--50N . . . . . . . . . . . . . . . . . . . . . . . . . .137
C500--CE241 . . . . . . . . . . . . . . . . . . . . . . .130
PFP--M . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
C500--CE242 . . . . . . . . . . . . . . . . . . . . . . .130
PFP--S . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
C200HW--ATT82. . . . . . . . . . . . . . . . . . . .136
C200HW--ATTA2 . . . . . . . . . . . . . . . . . . .136
C200HW--BC031 . . . . . . . . . . . . . . . .19, 124
C200HW--BC051 . . . . . . . . . . . . . . . .19, 124
C200HW--BC081 . . . . . . . . . . . . . . . .19, 124
C200HW--BC101 . . . . . . . . . . . . . . . .19, 124
C200HW--BI031 . . . . . . . . . . . . . . . . . . . . .19
C200HW--BI051 . . . . . . . . . . . . . . . . . . . . .19
C200HW--BI081 . . . . . . . . . . . . . . . . . . . . .19
C200HW--BI101 . . . . . . . . . . . . . . . . . . . . .19
C200HW--CE001 . . . . . . 75, 76, 78, 80, 131
C200HW--CE002 . . . . . . 75, 76, 78, 80, 131
C200HW--CE011 . . . . . . . . . .72, 73, 74, 131
C200HW--CE012 . . . . . . . . . .72, 73, 74, 131
C200HW--COM01 . . . 14, 75, 76, 78, 80, 124
C200HW--COM02 . . . . . . . . . . . . . . . .14, 124
C200HW--COM03 . . . . . . . . . . . . . . . .14, 124
C200HW--COM04--E . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . 14, 75, 76, 78, 80, 124
152
F
C200H--TS001 . . . . . . . . . . . . . . .42, 43, 127
C500--CE243 . . . . . . . . . . . . . . . . . . . . . . .130
FCS-CAK6230-US . . . . . . . . . . . . . . . . . . 133
FCS-HCR-_ _ -_ _ _ . . . . . . . . . . . . . . . . . 133
G
P
S
C500--CE244 . . . . . . . . . . . . . . . . . . . . . . .130
C500--CE401 . . . . . . . . . . . . . . . . . . .130, 136
C500--CE402 . . . . . . . . . . . . . . . . . . .130, 136
C500--CE403 . . . . . . . . . . . . . . . . . . .130, 136
C500--CE404 . . . . . . . . . . . . . . . . . . . . . . .130
C500--CE405 . . . . . . . . . . . . . . . . . . . . . . .136
C500--COV02 . . . . . . . . . . . . . . . . . . . . . .136
S300--COCH82 . . . . . . . . . . . . . . . . . . . . .133
S3200--COCF2011 . . . . . . . . . . . . . . . . . . 133
S3200--COCF2511 . . . . . . . . . . . . . . . . . . 133
S3200--COCF62F . . . . . . . . . . . . . . . . . . .133
S3200--COCF62M . . . . . . . . . . . . . . . . . . 133
S3200--COCH62M . . . . . . . . . . . . . . . . . . 133
S3200--COIAT2000 . . . . . . . . . . . . . . . . . 133
C500--Z3AT1--EV1.2 . . . . . . . . . . . . . . . . 138
S3200--NSB11--E . . . . . . . . . . . . . . . . . . .132
CQM1--CIF02 . . . . . . . . . . . . . . .98, 129, 135
SYSWINHL--V3.0 . . . . . . . . . . . . . . . . . . .138
CQM1--PRO01--E . . . . . . . . . . . . . . . .98, 135
CV500--CN244 . . . . . . . . . . . . . . . . . . . . .129
X
CV500--ZN3AT1--E . . . . . . . . . . . . . . 129, 138
XW2B--20J6--6 . . . . . . . . . . . . . . . . . . . . .129
CVM1--PRS71 . . . . . . . . . . . . . . . . . . . . . .129
XW2Z--100J--F1 . . . . . . . . . . . . . . . . . . . .129