C4V
Miniature Power Switch
Miniature Power Switch
with Contact gap of 3 mm
min.
● Unique snap-action mechanism allows
large-capacity switching.
C
4
V
● Sharp snap feeling with firm switching action.
● Contact gap of 3 mm min.
● UL, cUL standards approved. Conforms to EN
standards.
RoHS Compliant
(Please refer to "Precautions" for details.)
Typical Applications
• Power Switching
• Door Interlock
Ordering Information
Switching Functions
Momentary
Alternate
SPST
DPST
Contact Forms
2
Models
SPST
2
1
4
3
2
2
1
C4V-811M-D
C4V-821M
DPST
1
1
4
C4V-811A-D
3
C4V-821A
Specifications
Rating (resistive load)
8A 125/250 VAC
Ambient temperature
-10°C to +55°C 60%RH max. (with no icing or condensation)
Ambient humidity
45 to 85%RH (at +5 to 35°C)
Insulation resistance
100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value)
50 mΩ max. (at 6 VDC 1A)
Dielectric
strength
Between terminals of the same
polarity
3,000 VAC 50/60Hz 1 min
Between terminals of different
polarity
3,000 VAC 50/60Hz 1 min
Between current-carrying
metal parts and ground
3,000 VAC 50/60Hz 1 min
Vibration resistance
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Malfunction
147 m/s2 min.
Mechanical
10,000 operations min.
Durability
Electrical
10,000 operations min.
Degree of protection
IEC IP00
Operating force
7 N {714 gf} max.
Approved Safety Standard
●UL (UL1054/CSA C22.2 No.55)
8A 250 VAC
●TÜV (EN61058-1)
8A 250 VAC
1
C4V
Miniature Power Switch
Dimensions
(Units: mm)
●SPST
10±0.1
12
6 ±0.1
C
4
V
FP
Operating Force
OF
7 N {714 gf} max.
Free Position
FP
24.0±0.2mm
Operating
Position
OP
21mm min.
Total Travel
Position
TTP
19.5±0.2mm
Releasing
Position
RP
21.5mm min.
Set Position
SP
21.4±0.3mm
* mark part: In case of the alternative model,
"RP" means "SP"
RP*
OP TTP
14.5
12.25 ±0.2
±0.1
6.5
±0.1
8
±0.2
4.75
0.8
11.6
17.2±0.1
13
19±0.1
●DPST
10±0.1
12
6 ±0.1
Operating Force
OF
7 N {714 gf} max.
Free Position
FP
24.0±0.2mm
Operating
Position
OP
21mm min.
Total Travel
Position
TTP
19.5±0.2mm
Releasing
Position
RP
21.5mm min.
Set Position
SP
21.4±0.3mm
* mark part: In case of the alternative model,
"RP" means "SP"
FP
RP* OP TTP
14.5
12.25 ±0.2
6.5 ±0.1
±0.1
8±0.2
4.75
0.8
11.6
13
17.2±0.1
19±0.1
Note. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions
described in the above figure.
Operating specifications/Internal connection
●DPST
●SPST
2
2
1
4
3
1
Panel Cutout
X
Y
Z
The above figure is an example of the mounting method.
2
Direction
Dimensions
(mm)
X
17.4 +0.15
0
Y
13.2
Z
+0.15
0
0
5.5 –0.15
C4V
Miniature Power Switch
Precautions
Warning
Please do not perform wiring or touch the charged
parts of terminals while power is supplied to the
Switch, as electric shock may occur.
Caution
• Use the switch within the rated voltage and current ranges,
otherwise the switch may have reduced durability, radiate
heat, or burn out.
This particularly applies to the instantaneous voltages and
currents when switching.
●Environment for Storage and Use
• To prevent deterioration such as discoloration of the terminals
and other problems during storage, do not store/use the switch
in location subject to the following conditions.
1. High temperatures or humidity
2. Corrosive gases
3. Direct sunlight
4. Sea wind
Also, the switch is not waterproof or splash-resistant. Do not
install or use the switch in locations that are subject to contact
with water, oil or dust.
• Do not subject the switch to freezing conditions or
condensation.
Correct Use
●Mounting
• Pay attention to the creepage distance/clearance distance for
insulation after wiring onto terminal when mounting frame is
made of metal.
●Wiring
• Please use the receptacle that is compatible with 4.8×0.8 mm
quick connect terminal (#187) when using it as a quick connect
terminal.
• Ensure that the wires are thick enough for the load (current) to
be applied.
• The performance of the Switch may be affected if used under
micro loads. Please test the Switch under actual operating
conditions.
• It is possible to use the terminals as a soldering terminal.
However, it is not in compliance with safety standards for use
as solder connection.
Please use it as the quick connect terminal when standard
approval is necessary.
• When soldering terminals manually, perform soldering within 5
seconds using a 60 W soldering iron (temperature at the tip of
the soldering iron: 350°C max.). Do not apply excessive force
to the terminals during soldering.
• Applying the tip of the soldering iron to the root side of the
terminal can cause deformation of the Housing and Base.
• This product does not correspond to the flow solder and reflow
solder.
It causes the malfunction by the infiltration of flux and the
thermal deformation.
●Handling
• Avoid shock damage to the product when handling. Shock can
cause deformation or break of the product.
• Do not apply excessive operating force to the switch to avoid
deformation or damage.
• Apply an operating force not exceeding 30N {3,059 gf}.
Do not apply a load from an angle or from the side of the
actuator.
●RoHS Compliant
The "RoHS Compliant" designation indicates that the listed
models do not contain the six hazardous substances covered by
the RoHS Directive.
Reference:
The following standards are used to determine compliance for
the six substances.
Lead
: 1,000 ppm max.
Mercury
: 1,000 ppm max.
Cadmium
: 100 ppm max.
Hexavalent chromium: 1,000 ppm max.
PBB
: 1,000 ppm max.
PBDE
: 1,000 ppm max.
3
C
4
V
C4V
Miniature Power Switch
C
4
V
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. A197-E1-04
1014(0207)(O)