0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CIMR-V7AZ47P5

CIMR-V7AZ47P5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    VARIABLE FREQUENCY DRIVE 460V

  • 数据手册
  • 价格&库存
CIMR-V7AZ47P5 数据手册
Y203-EN2-02-Katalog.book Seite 329 Mittwoch, 24. Mai 2006 2:22 14 CIMR-V7AZ Varispeed V7 Sensorless vector in pocket size • • • • • • • • • • • • Nominal torque at 0.5 Hz Autotuning High carrier up to 14 khz Stop accuracy function. Integrated PID controller and bidirectional PID-out put Motor protection with PTC input Pulse input Standard digital operator with copy function Fieldbus: Modbus, DeviceNet, PROFIBUS, CANopen High speed motion bus: ML- II Plug-in PLC option unit. Total inverter access. CE, UL, and cUL marked V7 IP65 • Compact size • Easy wiring • Built-in filter (Class B) Customized software* • The inverter software can be customized to meet specific application. Examples: • Traverse sofware S-9381. *For detailed information please refer to case software section. Ratings • 200 V Class single-phase 0.1 to 4 kW • 200 V Class three-phase 0.1 to 7.5 kW • 400 V Class three-phase 0.2 to 7.5 kW System configuration 3G3IV-PCN329-E Inverter to PC cable 3G3IV-PEZZ8122_ DIN attachment CX-Drive Line filter JVOP-144 Remote digital oper. with potentiometer JVOP-146 Remote digital oper. with potentiometer *See note 3G3IV-PCN126/326 Digital operator extension cable Braking accessories Varispeed V7 LKEB_ CDBR_B ERF150WJ_ * V7 IP65 types are built-in filter inverters. Communication unit PLC option unit *See note *See note * Option frames are needed for V7 IP65 type. Varispeed V7 329 Y203-EN2-02-Katalog.book Seite 330 Mittwoch, 24. Mai 2006 2:22 14 Specifications Type designation CIMR—V7AZB0P10 Protective enclosure: 0: IP20 1: NEMA1 05: IP65 Inverter V7 series Max. applicable motor output 0P1: 0.1 kW ~ A: With digital operator (with potentiometer) T: V7 IP65 type with digital operator ( without potentiometer ) 7P5: 7.5 kW [ "P" indicates a decimal point ] Voltage B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC Z: European standard specifications 200 V class IP20 single-phase: CIMR-V7AZ B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 IP65 single-phase: CIMR-V7TZ --- --- B0P405 B0P705 B1P505 B2P205 --- IP20 three-phase: CIMR-V7AZ 20P1 0.12 20P2 0.25 20P4 0.55 20P7 1.1 21P5 1.5 22P2 2.2 24P0 4.0 Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Rated output current A 0.8 1.6 3.0 5.0 8.0 11.0 17.5 Max. output voltage Proportional to input voltage: 0..240 V Max. output frequency 400 Hz Rated input voltage and frequency Single-phase 200..240 V 50/60 Hz 3-phase 200..230 V 50/60 Hz Allowable voltage fluctuation -15%..+10% Allowable frequency fluctuation +5% Power supply Output characteristics Maximum permissible motor output kW1 1. B4P0 Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current 40P2 40P4 40P405 40P7 40P705 41P5 41P505 42P2 42P205 43P0 43P005 44P0 44P005 Maximum permissible motor output kW1 0.37 0.55 1.1 1.5 2.2 3.0 4.0 5.5 7.5 Output characteristics 400 V class Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.0 11.0 14.0 Rated output current A 1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 IP20 three-phase: CIMR-V7AZ Power supply IP65 three-phase: CIMR-V7TZ 1. 330 Max. output voltage Proportional to input voltage: 0..400 V Max. output frequency 400 Hz Rated input voltage and frequency 3-phase 380..460 VAC, 50/60 Hz Allowable voltage fluctuation -15%..+10% Allowable frequency fluctuation +5% 45P5 47P5 Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current Frequency inverters Y203-EN2-02-Katalog.book Seite 331 Mittwoch, 24. Mai 2006 2:22 14 Commom specifications Model number CIMR-V7AZ-@ CIMR-V7TZ-@ Control methods Sine wave PWM (V/f control, sensorless vector control) Output frequency range 0.1..400 Hz Digital set value: ±0.01% (-10..+50 ºC) Analogue set value: ±0.5% (25 ±10 ºC) Digital set value: 0.01 Hz (100 Hz) Analogue set value: 1/1000 of maximum frequency 0.01 Hz Control functions Frequency tolerance Resolution of frequency set value Resolution of output frequency Overload capability Frequency set value Braking torque (short term peak torque) Functionality Binary inputs Binary outputs 1 relay output, 2 freely programmable open collector outputs 1 programmable analogue output (0..10 V)/pulse output Analogue inputs 2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA Braking/acceleration times 0.01..6000 s Optionally frequency, current or set value Error and status LED Motor overload protection Electronic thermal overload relay Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current Overload Protection functions 150%/60 s 0..10 V (20 kΩ), 4..20 mA (250 Ω), 0..20 mA (250 Ω) Pulse train input, frequency setting value (selectable) Up to 200 W 150% or more 550 W to 1.1 kW 100% or more 1.5 kW 50% or more >1.5 kW 20% or more Continuous braking torque approx. 20% without, 150% with external braking resistor 7 freely programmable inputs Analogue output Display Overvoltage Undervoltage Momentary power loss Motor coasts to a stop after 1 minute at 150% of inverter rated output current Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class) Stops when DC bus voltage is approx. 200 V or less (double for 400 V class) (approx. 160 V or less for single-phase series) Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is approx. 0.5 s or shorter, continuous operation Cooling fin overheat Protected by electronic circuit Stall prevention level Individual levels during accel/constant speed. Decel ON/OFF available. During decel enable/disable selectable. Cooling fan fault Ground fault Power charge indication Degree of protection Ambient conditions Specifications Cooling Ambient temperature Ambient humidity Storage temperature Installation Installation height Vibration Varispeed V7 Detected by electronic circuit (fan lock detection) Protected by electronic circuit (operation level is approx. 250% of rated output current) RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less. (Charge LED is provided for 400 V) IP20, NEMA1, IP65 Self cooling for 200 V 0.1..0.4 kW (3 or single phase) and for 400 V 0.2..0.75 kW Cooling fan for 200 V 0.75 to 7.5 kW and for 400 V 1.5 to 7.5 kW Open air mounting: -10 ºC..50 ºC Wall mounting: -10 ºC..40 ºC 95% (without condensation) -20 ºC..+60 ºC (short-term temperature during transportation) Indoor (no corrosive gas, dust, etc.) Max. 1000 m 10 to 20 Hz, 9.8 m/s2 max; 20 to 50 Hz, 2 m/s2 max 331 Y203-EN2-02-Katalog.book Seite 332 Mittwoch, 24. Mai 2006 2:22 14 Digital operator Data display Indicators (setting/monitor item indicators) FREQUENCY adjuster Operation keys Appearance Data display Name Function Displays relevant data items, such as frequency reference, output frequency, and parameter set values. Frequency adjuster Sets the frequency reference within a range between 0 Hz and the maximum frequency. 1 Frequency reference indicator The frequency reference can be monitored or set while this indicator is lit. Output frequency indicator The output frequency of the inverter can be monitored while this indicator is lit. Output current indicator The output current of the inverter can be monitored while this indicator is lit. Multi-function monitor indicator The values set in U01 through U10 are monitored while this indicator is lit. Forward/reverse selection indicator The direction of rotation can be selected while this indicator is lit when operating the inverter with the RUN key. The operation of the inverter through the digital operator or according to the set parameters is selectable while this indicator is lit. 2 The parameters in n001 through n179 can be set or monitored while this indicator is lit. 3 Local/remote selection indicator Parameter setting indicator 1. 2. 3. 4. 332 Mode key Switches the simplified-LED (setting and monitor) item indicators in sequence. Parameter being set will be canceled if this key is pressed before entering the setting. Increment key Increases multi-function monitor numbers, parameter numbers, and parameter set values. Decrement key Decreases multi-function monitor numbers, parameter numbers, and parameter set values. Enter key Enters multi-function monitor numbers, parameter numbers, and internal data values after they are set or changed. RUN key Starts the inverter running when the 3G3MV is in operation with the digital operator STOP/RESET key Stops the inverter unless parameter n007 is set to disable the STOP key. Used to reset the inverter when an error occurs. 4 V7 IP65 types have digital operator without frequency adjuster. The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit. While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the parameter setting indicator is lit. For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF before using this function. Frequency inverters Y203-EN2-02-Katalog.book Seite 333 Mittwoch, 24. Mai 2006 2:22 14 Dimensions IP 20 type 0.1 to 4 Kw 4 M4 D1 8.5 (0.34) H2 W1 W H2 H1 H H1 H 2 M4 W1 W D Figure 1 Voltage class Three-phase 200 V Single-phase 200 V Three-phase 400 V D1 8.5 (0.34) D Figure 2 Max. applicable motor output kW Inverter model CIMR V7AZ 0.12 20P1 0.25 20P2 0.55 20P4 1.1 20P7 1.5 21P5 2.2 22P2 4.0 24P0 0.12 B0P1 0.25 B0P2 0.55 B0P4 1.1 B0P7 1.5 B1P5 2.2 B2P2 Figure Dimensions in mm W H D W1 H1 H2 76 1 68 108 128 2 108 140 140 10 56 128 131 143 5 118 96 5 128 68 76 56 118 5 131 2 128 140 96 96 140 163 128 1.1 10 170 180 158 64 118 0.6 62 64 5 71 1.4 1.5 1.5 1.5 2.2 40P2 92 16 1.0 0.55 40P4 110 34 1.1 1.1 40P7 1.5 41P5 2.2 42P2 3.0 43P0 4.0 44P0 2 128 140 143 Fan cooled 2.9 Self cooled 1.5 118 156 Self cooled 1.0 B4P0 96 Fan cooled 0.6 0.7 4.0 140 Self cooled 2.1 0.37 108 Cooling method 0.6 0.9 42 156 108 Weight kg 42 71 76 1 D1 5 64 1.5 1.5 128 71 2.1 Fan cooled 2.1 IP20 / NEMA1 type 5.5/7.5 Kw Figure 3 Max. applicable motor output kW Inverter model CIMR - V7AZ Three-phase 200 V 5.5 25P5 7.5 27P5 Three-phase 400 V 5.5 45P5 7.5 47P5 Voltage class Varispeed V7 Figure Dimensions in mm (inches) W H D W1 H1 H2 D1 180 260 170 164 244 8 65 3 180 260 170 164 244 8 65 Weight kg Cooling method 4.6 4.8 4.8 Fan cooled 4.8 333 Y203-EN2-02-Katalog.book Seite 334 Mittwoch, 24. Mai 2006 2:22 14 IIP65 type 0.55 to 4 Kw W2 H1 D D1 H W W1 H1 H2 6.4 3x PG25 Figure 4 Voltage class Single-phase 200 V Three-phase 400 V 334 Max. applicable motor output kW Inverter model CIMR V7TZ Dimensions in mm 0.55 1.1 1.5 B1P505 2.2 B2P205 0.55 40P405 1.1 40P705 1.5 41P505 2.2 42P205 3.0 43P005 4.1 4.0 44P005 4.1 Weight kg Cooling method B0P405 3.4 Self cooled B0P705 4.3 Figure W 280 H 240 D 142 W1 260 W2 228 H1 165 H2 38 H3 275 D1 44 3.7 Fan cooled 4.2 4.2 4 Self cooled 4.3 280 240 142 260 228 165 38 275 44 3.7 3.7 Fan cooled Frequency inverters Y203-EN2-02-Katalog.book Seite 335 Mittwoch, 24. Mai 2006 2:22 14 IP65 type 0.55 to 4Kw (with option frame accessory attached) W2 H1 D2 D D1 H W W1 H1 H2 6.4 Voltage class Max. applicable motor output kW Singlephase 200 V Three-phase 400 V Varispeed V7 Inverter Figure model CIMR V7TZ Figure 5 3x PG25 2x PG12 Dimensions in mm W H D W1 W2 H1 H2 H3 D1 D2 Weight kg Cooling method Self cooled 0.55 B0P405 3.6 1.1 B0P705 4.5 1.5 B1P505 2.2 B2P205 0.55 40P405 1.1 40P705 1.5 41P505 2.2 42P205 3.0 43P005 4.3 4.0 44P005 4.3 280 240 180 260 228 165 38 275 44 38 3.9 Fan cooled 4.4 4.4 5 Self cooled 4.5 280 240 180 260 228 165 38 275 44 38 3.9 3.9 Fan cooled 335 Y203-EN2-02-Katalog.book Seite 336 Mittwoch, 24. Mai 2006 2:22 14 Filters * Dimensions Schaffner model A B C D E F G H I J K L 3x200 V 3G3MV-PFI2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4 3G3MV-PFI2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4 3G3MV-PFI2030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 1x200 V 3G3MV-PFI1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4 3G3MV-PFI1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4 3G3MV-PFI1030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 3G3MV-PFI1040-SE 174 144 50 135 161 150 5 M5 25 158 118 M4 3x400 V 3G3MV-PFI3005-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 3G3MV-PFI3010-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 3G3MV-PFI3020-SE 174 144 50 135 161 120 5 M5 25 128 118 M4 3G3MV-PFI3030-SE 304 184 56 264 288 150 6 M5 28 164 244 M5 Drive mounts Output flexes Rasmi model 3x200 V 1x200 V 3x400 V Dimensions W H L X Y Inverter fixing 3G3MV-PFI2010-E 82 50 194 181 62 M5 3G3MV-PF2020-E 111 50 169 156 91 M5 3G3MV-PFI2030-E 144 50 174 161 120 M5 3G3MV-PFI2050-E 184 56 304 288 150 M5 3G3MV-PFI1010-E 71 45 169 156 51 M5 3G3MV-PFI1020-E 111 50 169 156 91 M5 3G3MV-PFI1030-E 144 50 174 161 120 M5 3G3MV-PFI1040-E 174 50 174 161 150 M5 3G3MV-PFI3005-E 111 50 169 156 91 M5 3G3MV-PFI3010-E 111 50 169 156 91 M5 3G3MV-PFI3020-E 144 50 174 161 120 M5 3G3MV-PFI3030-E 184 56 304 288 150 M5 * V7 IP65 types are built-in filter inverters. 336 Frequency inverters Y203-EN2-02-Katalog.book Seite 337 Mittwoch, 24. Mai 2006 2:22 14 DIN rail mounting bracket DIN (35 Four, M4 tap rail 3G3IV-PZZ08122B .1 ) 3G3IV-PZZ08122A Four, M4 tap Side view (common to all the units) 3G3IV-PZZ08122D 3G3IV-PZZ08122C Four, M4 tap 3-phase 200 VAC Single-phase 200 VAC 3-phase 400 VAC Varispeed V7 Inverter CIMR-V7AZ - 20P1/ 20P4/ 20P7 CIMR-V7AZ - 21P5/ 22P2 CIMR-V7AZ - 24P0 CIMR-V7AZ - B0P1/ B0P2/ B0P4 CIMR-V7AZ - B0P7/ B1P5 CIMR-V7AZ - B2P2 CIMR-V7AZ - B4P0 CIMR-V7AZ - 40P2/ 40P4/ 40P7/ 41P5/ 42P2 CIMR-V7AZ - 44P0 Four, M4 tap DIN rail mounting bracket 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122D 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 337 Y203-EN2-02-Katalog.book Seite 338 Mittwoch, 24. Mai 2006 2:22 14 Attachments Heatsink external mounting attachment When mounting an external cooling-fan to the V7AZ, this attachment is required. Attachment order code D1 D2 D3 V7AZ-20P1 V7AZ-20P2 V7AZ-20P4 EZZ08136A 69.2 12 30 EZZ08136B 69.2 42 50 V7AZ-20P7 EZZ08136C 69.2 62 70 73 58 70 98 58 70 V7AZ-21P5 V7AZ-22P2 EZZ08136D V7AZ-24P0 -EZZ08136F 78.6 64.4 70 V7AZ-25P5 V7AZ-27P5 V7AZ-B0P1 V7AZ-B0P2 V7AZ-B0P4 EZZ08136H 113.8 56.2 60 EZZ08136A 69.2 12 30 EZZ08136B 92.2 42 50 82 58 70 98 58 70 70 V7AZ-B0P7 V7AZ-B1P5 EZZ08136D V7AZ-B2P2 EZZ08136F 98.6 64.4 V7AZ-B4P0 EZZ08136G 115.6 64.4 70 V7AZ-40P2 EZZ08136E 82 13.2 30 82 28 40 EZZ08136D 82 58 70 98 58 70 EZZ08136F 78.6 64.4 70 EZZ08136H 113.8 56.2 60 V7AZ-40P4 V7AZ-40P7 V7AZ-41P5 V7AZ-42P2 V7AZ-43P0 V7AZ-44P0 V7AZ-45P5 V7AZ-47P5 338 Dimensions in mm CIMR-V7AZ Frequency inverters Y203-EN2-02-Katalog.book Seite 339 Mittwoch, 24. Mai 2006 2:22 14 Braking resistor unit ERF-150WJ Note: Prepare mounting screws (2-M4x8 tapped screws). Screws 8mm or more and general metric screws cannot be used. Braking resistors unit 150 or more B D 150 or more MTG screw C 30 or more A 30 or more 150 Voltage 200 V class 400 V class B C D MTG.screw Approx. weight kg 20P7 105 275 50 260 M5x3 3.0 21P5 130 350 75 335 M5x4 4.5 22P2 130 350 75 335 M5x4 4.5 40P7 130 350 75 350 M5x4 5.0 25P5 250 350 200 335 M6x4 7.5 27P5 350 350 200 335 M6x4 8.5 40P7 105 275 50 260 M5x3 3.0) 41P5 130 350 75) 335 M5x4 4.5 42P2 130 350 75) 335 M5x4 4.5 130 350 75 335 M5x4 5.0 45P5 250 350 200 335 M6x4 7.5 47P5 350 350 200 335 M6x4 8.5 43P0 43P7 Varispeed V7 Dimensions in mm A Model LKEB-# 339 Y203-EN2-02-Katalog.book Seite 340 Mittwoch, 24. Mai 2006 2:22 14 Installation Standard connections Thermal overload relay (option) DC reactor (option) U X Short bar +2 MCCB +1 – B1 B2 R/L1 R Line filter 1* S T S/L2 U/T1 T/L3 Forward run/stop S1 PHC Reverse run/stop S2 PHC External fault (no contact) S3 PHC Fault reset S4 PHC Multi-step speed reference 1 S5 PHC Multi-step speed reference 2 S6 PHC JOG command S7 PHC SC 2kΩ Frequency reference P 24 V W/T3 Grounding MA MB P P1 PNP PC Housing (type : ZHR-3) CN2 max AM R– (1/2 W. 120 Ω) P 4 to 20 mA 0V GND R+ Terminal resistance 0 to 10 V VIN IIN min S+ Multi-function photocoupler output +48 VDC 50 mA or less Speed agree Digital operator frequency setting potentiometer MEMOBUS communication RS-485/422 max 19.2kBPS Running P2 0V Frequency setter Multi-function output 250 VAC 1 A or less 30 VDC 1 A or less Fault MC Shield connection terminal Speed reference RP pulse train (33 kHz max.) Frequency setting FS power supply (+12 V 20 mA) Speed frequency FR reference 0 to +10 V (20 kΩ) OR FC 4 to 20 mA (250 Ω) Pulse train input IM V/T2 NPN Multifunction input Braking resistor (option) AC Multi-function analog input 2* Frequency meter adjusting potentiometer Analog monitor output TO +10 VDC (2 mA) P FM 0Pulse monitor output Output (12 VDC frequency 20 mA max. 30 - 70% duty) S– 1* V7 IP65 types are built-in filter. 2* A housing is required when using the CN2 terminal on the back side of the digital operator. 1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request : shielded wire P : twisted pair shielded wire Shows the following two kinds of connections (factory setting) : · Input signals (S1 to S7) are non-voltage contacts · Sequence connection by NPN transistor (0V common) A +24 V power supply is required for sequence connection by PNP transistor (+24 V common) . 340 Frequency inverters Y203-EN2-02-Katalog.book Seite 341 Mittwoch, 24. Mai 2006 2:22 14 Main circuit Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 B1, B2 +2, +1 +1, – Name AC power supply input Function (signal level) Inverter output Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0.75 kW for other usage, such as a junction terminal.) For inverter output Braking resistor connection For braking resistor connection DC reactor connection Remove the short bar between +2 and +1 when connecting DC reactor (option) DC power supply input For power supply input (+1: positive electrode; – : negative electrode)* Grounding For grounding (grounding should conform to the local grounding code.) Control Circuit RS-485/422 Analog output signals Digital output signals Analog input signals Digital input signals Type No. Signal name Function S1 Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN. S2 Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN. S3 Multi-function input selection 3 Factory setting: "fault reset" S4 Multi-function input selection 4 Factory setting: "external fault (NO contact)" S5 Multi-function input selection 5 Factory setting: "multi-step speed reference 1" S6 Multi-function input selection 6 Factory setting: "multi-step speed reference 2" S7 Multi-function input selection 7 Factory setting: "JOG command" SC Multi-function input selection Common Common for control signal RP Speed reference pulse train input 33 kHz max. FS Power supply terminal for frequency setting +12V (allowable current: 20 mA max.) FR Speed frequency reference 0 to +10 VDC (20 kΩ) or 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) (resolution 1/1000) FC Frequency reference common 0V 1 (CN2) Multi-function analog voltage input Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 kΩ) 2 (CN2) Multi-function analog current input Current input (between terminals 2 and 3): 4 to 20 mA (input impedance: 250 Ω) 3 (CN2 Multi-function analog input common MA NO contact output NC Contact output MC Contact output common P1 Photocoupler output 1 Factory setting: "running" P2 Photocoupler output 2 Factory setting: "at frequency" PC Photocoupler output common 0V AM Analog monitor output AC Analog monitor common R+ Communication input (+) R– Communication input (–) S+ Communication output (+) S– Communication output (–) Varispeed V7 Factory setting: "fault" Factory setting: "output frequency" 0 to +10 V output (pulse monitor output available by setting constants. Duty: 30 to 70%) 0V For MEMOBUS communication operation by RS-485 or RS-422 communication is available. Signal level 24VDC, 8mA photocoupler insulation Contact capacity 250 VAC, 1 A or less 30 VDC, 1 A or less Photocoupler output: +48 VDC, 50 mA or less 0 to 10 V 2 mA or less Resolution: 8 bits RS-485/422 MEMOBUS protocol 19.2 kBPS max. 341 Y203-EN2-02-Katalog.book Seite 342 Mittwoch, 24. Mai 2006 2:22 14 30 mm min. (0.1 to 4.0 KW) 50 mm min. (5.5 and 7.5 KW) W= Inverter Inverter Air 100 mm min. Inverter Side 100 mm min. Air Inverter heat loss Three-phase 200 V class 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 Rated current A 0.8 1.6 3 5 8 11 17.5 25 33 219.2 Heat loss W Model CIMR-V7AZ Inverter capacity kVA 27P5 Fin 3.7 7.7 15.8 28.4 53.7 60.4 96.7 170.4 Inside unit 9.3 10.3 12.3 16.7 19.1 34.4 52.4 79.4 98.9 Total heat loss 13.0 18.0 28.1 45.1 72.8 94.8 149.1 249.8 318.1 B4P0 Single-phase 200 V class B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Rated current A 0.8 1.6 3 5 8 11 17.5 Heat loss W Model CIMR-V7AZ Inverter capacity kVA Fin 3.7 7.7 15.8 28.4 53.7 64.5 98.2 Inside unit 10.4 12.3 16.1 23.0 29.1 49.1 78.2 Total heat loss 14.1 20.0 31.9 51.4 82.8 113.6 176.4 Three-phase 400 V class 40P2 40P4 40P7 41P5 42P2 44P0 45P5 1.4 2.6 3.7 4.2 5.5 7.0 11 14 Rated current A 1.8 3.4 4.8 5.5 7.2 8.6 14.8 18 209.6 Heat loss W Model CIMR-V7AZ Inverter capacity kVA 47P5 Fin 15.1 30.3 45.8 50.5 58.2 73.4 168.8 Inside unit 15.0 24.6 29.9 32.5 37.6 44.5 87.7 99.3 Total heat loss 30.1 54.9 75.7 83.0 95.8 117.9 256.5 308.9 Installation conditions for IP65 Install the inverter vertically in order to ensure proper cooling. When installing the inverter, always provide the following minimum installation space to allow normal heat dissipation. 50 mm or more 120 mm or more Air 40 mm or more 50 mm or more Side spaces 40 mm or more 120 mm or more Air Top and bottom spaces 1. Always provide enough space for the main circuit or control lines including cable gland. 2. If installing inverters next to one another, provide a minimum spacing of 60mm. 342 Frequency inverters Y203-EN2-02-Katalog.book Seite 343 Mittwoch, 24. Mai 2006 2:22 14 Connections for braking resistor Braking resistor 3-phase power supply Motor Connections for braking resistor unit Overload relay trip contact Braking resistor unit Use sequencer to break power supply side on overload relay trip contact Power supply 3-phase Braking resistor unit overheat contact Faulr contact AC reactor AC reactor Motor Be sure to connect AC reactor on inverter input side [L1 (R), L2 (S), L3 (T)]. Max. applicable motor output kW 0.12 0.25 0.55 1.1 1.5 2.2 4.0 5.5 7.5 Varispeed V7 200 V class Current value A 2.0 2.0 2.5 5 10 15 20 30 40 Inductance mH 2.0 2.0 4.2 2.1 1.1 0.71 0.53 0.35 0.265 Max. applicable motor output kW 0.2 0.4 0.75 1.5 2.2 4.0 5.5 7.5 400 V class Current value A ------ Inductance mH 1.3 18.0 2.5 5 7.5 10 15 20 8.4 4.2 3.6 2.2 1.42 1.06 343 Y203-EN2-02-Katalog.book Seite 344 Mittwoch, 24. Mai 2006 2:22 14 DC reactor DC reactor Motor 200 V class Max. applicable motor output kW Current value A 400 V class Inductance mH Max. applicable motor output kW 0.12 0.25 0.55 5.4 8 344 0.2 0.4 3.2 28 5.7 11 12 6.3 23 3.6 0.75 1.5 1.5 18 3 2.2 4.0 4.0 5.5 5.5 7.5 Inductance mH -------- 1.1 2.2 Current value A 36 1 7.5 Frequency inverters Y203-EN2-02-Katalog.book Seite 345 Mittwoch, 24. Mai 2006 2:22 14 Ordering information 3G3IV-PCN329-E Inverter to PC cable CX-Drive 3G3IV-PEZZ8122_ DIN attachment JVOP-144 Remote digital oper. with potentiometer JVOP-146 Remote digital oper. with potentiometer 3G3IV-PCN126/326 Digital operator extension cable D D D D D D *See note Line filter Braking accessories Varispeed V7 LKEB_ A E CDBR_B ERF150WJ_ * V7 IP65 types are built-in filter inverters. Communication unit PLC option unit *See note B *See note C * Option frames are needed for V7 IP65 type. Varispeed V7 200 V 400 V Specifications 1x200 V 3x200 V Varispeed V7 Model 0.12 Kw 0.8 A CIMR-V7AZB0P10 0.25 Kw 1.6 A 0.55 Kw 3.0 A 1.1 Kw Specifications 3x400 V Model 0.37 Kw 1.2 A CIMR-V7AZ40P20 CIMR-V7AZB0P20 0.55 Kw 1.8 A CIMR-V7AZ40P40 CIMR-V7AZB0P40 1.1 Kw 3.4 A CIMR-V7AZ40P70 5.0 A CIMR-V7AZB0P70 1.5 Kw 4.8 A CIMR-V7AZ41P50 1.5 Kw 8.0 A CIMR-V7AZB1P50 2.2 Kw 5.5 A CIMR-V7AZ42P20 2.2 Kw 11.0 A CIMR-V7AZB2P20 3.0 Kw 7.2 A CIMR-V7AZ43P00 4.0 Kw 17.5 A CIMR-V7AZB4P00 4.0 Kw 9.2 A CIMR-V7AZ44P00 0.12 Kw 0.8 A CIMR-V7AZ20P10 5.5 Kw 14.8 A CIMR-V7AZ45P51 0.25 Kw 1.6 A CIMR-V7AZ20P20 7.5 Kw 18.0 A CIMR-V7AZ47P51 0.55 Kw 3.0 A CIMR-V7AZ20P40 1.1 Kw 5.0 A CIMR-V7AZ20P70 1.5 Kw 8.0 A CIMR-V7AZ21P50 2.2 Kw 11.0 A CIMR-V7AZ22P20 4.0 Kw 17.5 A CIMR-V7AZ24P00 5.5 Kw 25.0 A CIMR-V7AZ25P51 7.5 Kw 33.0 A CIMR-V7AZ27P51 345 Y203-EN2-02-Katalog.book Seite 346 Mittwoch, 24. Mai 2006 2:22 14 Varispeed V7 IP65 200 V 400 V Specifications 1x200 V Model Specifications 0.55 Kw 3.0 A CIMR-V7TZB0P405 1.1 Kw 5.0 A 1.5 Kw 8.0 A 2.2 Kw 11.0 A 3x400 V Model 0.55 Kw 1.8 A CIMR-V7TZ40P405 CIMR-V7TZB0P705 1.1 Kw 3.4 A CIMR-V7TZ40P705 CIMR-V7TZB1P505 1.5 Kw 4.8 A CIMR-V7TZ41P505 CIMR-V7TZB2P205 2.2 Kw 5.5 A CIMR-V7TZ42P205 3.0 Kw 7.2 A CIMR-V7TZ43P005 4.0 Kw 9.2 A CIMR-V7TZ44P005 ALine filters * Inverter Voltage 3-Phase 200 VAC Single-Phase 200 VAC 3-Phase 400 VAC Line filter Model CIMR-V7AZ Schaffner Rasmi Rated current (A) Weight (kg) 20P1 / 20P2 / 20P4 / 20P7 3G3MV-PFI2010-SE 3G3MV-PFI2010-E 10 0.8 21P5 / 22P2 3G3MV-PFI2020-SE 3G3MV-PFI2020-E 20 1.0 24P0 3G3MV-PFI2030-SE 3G3MV-PFI2030-E 30 1.1 25P5 / 27P5 - 3G3MV-PFI2050-E 50 2.3 B0P1 / B0P2 / B0P4 3G3MV-PFI1010-SE 3G3MV-PFI1010-E 10 0.6 B0P7 / B1P5 3G3MV-PFI1020-SE 3G3MV-PFI1020-E 20 1.0 B2P2 3G3MV-PFI1030-SE 3G3MV-PFI1030-E 30 1.1 B4P0 3G3MV-PFI1040-SE 3G3MV-PFI1040-E 40 1.2 40P2 / 40P4 3G3MV-PFI3005-SE 3G3MV-PFI3005-E 5 1.0 40P7 / 41P5 / 42P2 3G3MV-PFI3010-SE 3G3MV-PFI3010-E 10 1.0 43P0 / 44P0 3G3MV-PFI3020-SE 3G3MV-PFI3020-E 15 1.1 45P5 / 47P5 3G3MV-PFI3030-SE 3G3MV-PFI3030-E 30 2.3 * V7 IP65 types are built-in filter inverters. 346 Frequency inverters Y203-EN2-02-Katalog.book Seite 347 Mittwoch, 24. Mai 2006 2:22 14 B Communication cards Type Model 1 3G3MV-PDRT2 Description DeviceNet option card 2 SI-P1/V7 Function • Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller. • Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller. Communication option board PROFIBUS-DP option card • Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. SI-S1/V7 Can open option card • Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. 3G3MV-PCORT21 Can open gateway SI-T1/V7 MECHATROLINK-II option card 1. 2. 3. • Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller. • High speed motion bus. • Host controller: TrajeXia, MCH or MP series.3 Option frame accessory is needed for V7 IP65 types when communications option units are used. For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used. Please refer to TrajeXia, MCH or MP series section for host controller technical information. C PLC option card Type Model 1 3G3MV-P10CDT-E Description PLC option PLC option Function • Full PLC featrues, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs. • Standard OMRON tools can be used for programming • Calendar / clock • Same features as standard models with RS 422/485 support. PLC option with RS 422/485 3G3MV-P10CDT3-E 1. Option frame accessory is needed on V7 IP65 types when PLC option unit is used. D Option frame accessory for V7 IP65 Type Model Description Option frame V7TZ-FR1 Varispeed V7 Function • Frame accessory is needed when communication option unit or PLC option unit are used with Varispeed V7 IP65. Option frame 347 Y203-EN2-02-Katalog.book Seite 348 Mittwoch, 24. Mai 2006 2:22 14 E Accessories Description Functions 4-4.4 DIA. dia. MTG 4-4.4 MTGholes HOLES DATA (15.5) STOP Remote digital operator without potentiometer 1.7 5 (0.07) (0.2) 12.2 (0.48) 10.5 (0.41) 18.2 30.4 (0.72) (1.20) 56 (2.20) 4-M4SPOT spot facing 4-M4 FACING DEEP 3.5(0.14) (0.14) deep 3.5 15.5 (0.61) 70 (2.76) Remote digital operator with potentiometer RUN STOP RESET MIN MAX 78 (3.07) 88 (3.46) 5 (0.2) 1.7 (0.07) 12.2 (0.48) 23.1 (0.91) 9.3 (0.37) 10.5 (0.41) 18.2 30.4 (0.72) (1.20) 68 (2.68) DSPL DATA ENTER 50 (1.97) JVOP-144 DIGITAL OPERATOR JVOP-140 80 (3.15) 4-4.4 DIA. dia. MTG 4-4.4 MTGholes HOLES 11 58 (2.28) (0.43) Digital operator 23.1 (0.91) 78 (3.07) 88 (3.46) 68 (2.68) 58 (2.28) 11 (0.43) JVOP-146 50 (1.97) Model 80 (3.15) Types 56 (2.20) 4-M4 SPOT FACING 4-M4 spot DEEP 3.5 facing (0.14) deep 3.5 (0.14) 15.5 (0.61) 70 (2.76) Accessories 72606-CVS31060 3G3IV-PEZZ0838BA 3G3IV-PCN126 3G3IV-PCN326 3G3IV-PCN329-E Blank cover Digital operator case Digital operator extension cable 1 meter 3 meters PC configuration cable ----same as JVOP-144 without operator --------- Types Model Description Software E Computer software CX-drive Computer software Configuration and monitoring software tool CX-One Computer software Configuration and monitoring software tool 348 Installation Frequency inverters Y203-EN2-02-Katalog.book Seite 349 Mittwoch, 24. Mai 2006 2:22 14 F Braking unit, braking resistor unit Inverter Voltage Max. applicable motor output kW 200 V (single-/ three-phase) 400 V (threephase) Varispeed V7 Braking resistor unit Inverter model CIMR-V7AZ Inverter-mounted type (3 %ED, 10 sec max) Separately-installed type (10 %ED, 10 sec. max.) Braking torque % Threephase Singlephase Model ERF150WJ_ Resistance Ω No. of used Braking torque % Model LKEB# Resistor spec. (per one unit) W Ω No. of used 0.12 20P1 B0P1 401 400 1 220 – – – – 0.25 20P2 B0P2 401 400 1 220 – – – – 300 0.55 20P4 B0P4 201 200 1 220 20P7 70 200 1 220 200 1.1 20P7 B0P7 201 200 1 125 20P7 70 200 1 125 120 1.5 21P5 B1P5 101 100 1 125 21P5 260 100 1 125 60 2.2 22P2 B2P2 700 70 1 120 22P2 260 1 120 60 4.0 24P0 B4P0 620 62 1 100 23P7 390 40 1 125 32 5.5 25P5 – – – – – 25P5 520 30 1 115 9.6 780 20 70 Connectable min. resistance Ω 300 7.5 27P5 – – – – – 27P5 1 125 9.6 0.37 40P2 – 751 750 1 230 – – – – 750 750 0.55 40P4 – 751 750 1 230 40P7 70 750 1 230 1.1 40P7 – 751 750 1 130 40P7 70 750 1 130 510 1.5 41P5 – 401 400 1 125 41P5 260 400 1 125 240 2.2 42P2 – 301 300 1 115 42P2 260 250 1 135 200 3.0 43P0 – 4.0 44P0 – 401 400 2 105 43P7 390 150 1 135 100 5.5 45P5 – – – – – 45P5 520 100 1 135 32 7.5 47P5 – – – – – 47P5 780 75 1 130 32 349 Y203-EN2-02-Katalog.book Seite 350 Mittwoch, 24. Mai 2006 2:22 14 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I20E-EN-02 350 In the interest of product improvement, specifications are subject to change without notice. Frequency inverters
CIMR-V7AZ47P5 价格&库存

很抱歉,暂时无法提供与“CIMR-V7AZ47P5”相匹配的价格&库存,您可以联系我们找货

免费人工找货