CJ1W-TS561

CJ1W-TS561

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    INPUT MODULE 6 ANALOG

  • 数据手册
  • 价格&库存
CJ1W-TS561 数据手册
Model CJ1W-TS561 Thermocouple input unit INSTRUCTION SHEET ■ General Specifications Unit classification Compatible Racks Max. number of Units CPU Unit data area for inputs Insulation resistance Dielectric Strength Thank you for purchasing an OMRON product. Read this instruction sheet thoroughly and familiarise yourself with the functions and characteristics of the product before using it. To ensure safe and correct use of this Unit, also read the Operation- and Programming Manuals for your CJ1 PLC system. Keep this instruction sheet for future reference. Internal current consumption Dimensions Weight Other OMRON MANUFACTURING OF THE NETHERLANDS B.V. ¤ OMRON Corporation 2004 All Rights Reserved ■ Unit Description The CJ1W-TS561 is a 6-channel input unit for K-type and J-type thermocouples. It can be installed in any CJ1-series PLC system. It is classified as a basic I/O unit, occupying 48, 64 or 96 I/O points, depending on the number of activated inputs. Always verify that the maximum I/O capacity of the CJ1 CPU is sufficient for the number of required I/O points. ■ Nomenclature Unit status indicators x RUN (green) x ERC (red) Sensor error indicators x 1 - 6 (red) Removable Terminal Block x Connections for Thermocouples 1 - 6 x CJ1W-TS561: screw terminal x CJ1W-TS561 (SL): screwless terminal DIP switches (remove terminal block for access) x Select input types (K-type/J-type) x Select filter functions x Select number of active inputs (1-6) Terminal Block latch x Slide down to remove x Slide up to lock ■ Characteristics Thermocouple input Number of inputs Measurement range Indication resolution Cold junction compensation - Accuracy Temperature value Data representation Indication accuracy * over full operational range (0 – 55 °C ambient temperature) Input response time (per active input) Input update cycle time (all active inputs) I/O refresh time (influence on PLC cycle time) Keep the thermocouple wiring as short as possible to avoid electrical interference. Shielded wiring is recommended. x When extending input wiring, always use compensation wires appropriate for the thermocouple type. x For activated but unused inputs, short-circuit the + and terminals, to prevent unstable readout on the other inputs. x Keep the input wiring away from power lines including AC power supply lines and high-power lines. Do not run the I/O lines in the same duct or conduit as power lines. x The input circuits are galvanically isolated from the PLC’s I/O bus, but there is no galvanic isolation between individual inputs. x Always ground the terminal on the Power Supply Unit of the PLC. In case of shielded sensor wiring, connect the shields to the same grounding point as the PLC. K-type or J-type (IEC 60584) 1 to 6 K-type: -200.0 to +1300.0 °C J-type: -100.0 to +850.0 °C 0.1 °C Internal measurement of terminal temperature, once in each scan cycle. ± 2.0 °C in a stable temperature environment (no direct heat or airflow). 16-bit signed integer in units of 0.1 °C: #F830 = -200.0 °C, #32C8 = +1300.0 °C ± 0.5 % of indicated value or ± 0.7 °C (whichever is larger) ± 1 digit max. ±2.0 °C ± 1 digit max. using a K-type thermocouple below –100 °C. 40 ms (100 Hz suppression) 67 ms (60 Hz suppression) 80 ms (50 Hz suppression) 400 ms (50+60 Hz suppression) [number of active inputs + 1] x [input response time] + 40 ms 1-3 inputs (48pt mode): 0.008 ms 4 inputs (64pt mode): 0.011 ms 5-6 inputs (96pt mode): 0.016 ms * Indication accuracy is guaranteed with the supplied terminal block. Do not replace the supplied terminal block by a different model (e.g. screw type by screwless type or vice versa). ■ LED indicators Name RUN (Green) State OFF ■ Wiring x CJ-series Basic I/O Unit CJ-series CPU Rack or CJ-series Expansion Rack 10 Units/Rack max. (This requires a CJ1G or CJ1H CPU) Basic I/O area CIO0000 – 0999 (3, 4 or 6 words allocated in IO Table) 20 M: min. (at 500 V DC) between input terminals and PLC I/O bus. 500 V AC, 50/60 Hz for 1 min. (detection current: 1 mA), between Input terminals and PLC I/O bus. 220 mA max., 5 V DC, from the PLC I/O bus. 31 x 90 x 65 mm (W x H x D) 150 g max. Other general specifications conform to the CJ-series general specifications. See Operation Manual W393. ERC (Red) Sensor Error 1–6 (Red) ON OFF ON OFF ON All ON Description Fatal error or no power supply. x Check the host PLC’s CPU status, and the status of other I/O units. If all other units function normally, replace the Unit. Unit functions normally. No fatal errors. Incorrect DIP switch setting Fatal error in the Unit. x Check the CPU unit for error codes. x Re-start the PLC system. x If the ERC LED is still lit, replace the unit. x Measurement of the corresponding channel is within range, or x Channel has been deactivated by DIP switch settings x Measured temperature out-of-range, or x Thermocouple broken wire Calibration data not found or incorrect. The Unit should be returned to OMRON for calibration. ■ DIP switches ■ Data representation 8 DIP switches are accessible after removing the front terminal block. Switch settings are processed at time of power ON, and should not be changed while the unit is powered. Default (ex-factory) setting is all switches ON, i.e. all 6 inputs are active and set to K-type thermocouple, with filtering at n x 100 Hz. Be sure to adjust the settings to your requirements before use. SW 1, 2 and 3 : Input type selection Any combination of input types (different numbers of K-type/J-type sensors) can be set. SW 1 2 3 State OFF ON OFF ON OFF ON Input type selection Input channel 1 is J-type Input channel 1 is K-type Input channels 2 and 3 are J-type Input channels 2 and 3 are K-type Input channels 4, 5 and 6 are J-type Input channels 4, 5 and 6 are K-type SW 4 + 5 : Input filtering (valid for all active input channels) Use filtering if the measured value is affected by the mains frequency or other sources of electrical interference. SW4 OFF OFF ON ON SW5 OFF ON OFF ON Filtering n x 10 Hz suppression n x 50 Hz suppression n x 60 Hz suppression n x 100 Hz suppression Response time 400 ms each input 80 ms each input 67 ms each input 40 ms each input Measured temperatures are indicated in °C. Each input value occupies one word (16 bits) in the CIO area and is encoded as a signed integer, with a resolution of 0.1 °C. Examples: #0300 = #FF85 = Value #7AAA #7BBB #7CCC #8CCC ■ ‘Not Ready’ flag During initialisation after power-on, and in case of internal failure, a ‘Not Ready’ flag will be set in the PLC memory area A050 to A069 (Basic I/O Unit information area, refer to CJ1 Operation Manual W393 for details). The lower bit of each unit is the Not Ready flag; the error code indicated in the remaining bits is relevant for repair purposes only. While this flag is ON, the temperature sensor data indicated by the unit in the CIO area is invalid. Address A050 A051 A069 Create the I/O table in the PLC after changing the switch settings, to register the correct number of input words in the PLC CPU. The unit is registered as 48-point, 64-point, or 96-point input unit, depending on the number of 16-bit CIO words it occupies. SW6 OFF ON OFF ON OFF ON OFF ON SW7 OFF OFF ON ON OFF OFF ON ON SW8 OFF OFF OFF OFF ON ON ON ON Active inputs Occupied input words Not valid, ERC indicator will be ON 1 3 CIO words (1 used)* 1, 2 3 CIO words (2 used)* 1, 2, 3 3 CIO words 1, 2, 3, 4 4 CIO words 1, 2, 3, 4, 5 6 CIO words (5 used)* 1, 2, 3, 4, 5, 6 6 CIO words 1, 2, 3, 4, 5, 6 6 CIO words Description Calibration data invalid or error detected at start-up, e.g. cold junction temperature out of range. Sensor error, broken wire Measured value out of range (over max. Temperature) Measured value out of range (under min. Temperature) During initialisation after power ON, data of active inputs will be #0000 until the “Not Ready’ flag turns OFF. A055 Input words are allocated in the PLC’s CIO area as Basic I/O Unit, i.e. sequentially starting at the leftmost unit. See CJ1-series Operation Manual W393 for details. 76.8 °C -12.3 °C Measured values are updated in CIO memory in each I/O refresh cycle. The following values are to be interpreted as error codes: SW 6+7+8 : Input activation To prevent broken wire indication for unused inputs, and to reduce the number of input channels occupied in CIO memory, the number of required inputs can be set by SW 6+7+8. 768 (dec) = -123 (dec) = Bit 00 08 00 … 00 … 00 08 When Bit = ON Unit in rack 0, slot 0 is not ready Unit in rack 0, slot 1 is not ready Unit in rack 0, slot 2 is not ready … Unit in rack 1, slot 0 is not ready … Unit in rack 3, slot 9 is not ready Unit in rack 3, slot 10 is not ready ■ Unit cycle time The internal processing time for all measurements by the unit is determined by the number of active channels and the filter type. Unit initialisation Measure Cold Junction + Sensor error check Measure Channel 1 Measure Channel 2 * In these cases, more CIO words will be occupied than required for the active inputs. The remaining occupied CIO words will be filled with 0’s, and cannot be used as work bits. The cold junction compensation measurement and one sensor error check are executed each cycle. The cold junction measurement time depends on the input filter setting, whereas the sensor error check takes a fixed 40 ms. Example: If 4 inputs are active, and filtering is set to n x 50 Hz (response time = 80 ms): Each measurement cycle takes (4+1) x 80 + 40 ms = 440 ms. Measure Channel N OMRON ELECTRONICS LLC Phone: 1-847-843-7900 or 1-800-55-OMRON OMRON CORPORATION OMRON CANADA INC. Phone: 416-286-6465 Phone: 1-514-636-6676 (French) Note: Specification subject to change without notice Printed in The Netherlands 1634299-2A
CJ1W-TS561 价格&库存

很抱歉,暂时无法提供与“CJ1W-TS561”相匹配的价格&库存,您可以联系我们找货

免费人工找货