0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CS1G-CPU42H

CS1G-CPU42H

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CONTROL LOGIC CPU 64K PROG

  • 数据手册
  • 价格&库存
CS1G-CPU42H 数据手册
System Design Guide System Configuration .........................................................................................2 Dimensions/Mounting Dimensions .....................................................................9 General Specifications......................................................................................11 Common Specifications for CPU Units .............................................................12 Current Consumption for Power Supply Units ..................................................15 1 System Configuration ■ Basic System Configuration CS1 Inner Boards Loop Control Board CS1W-LCB01/05 Serial Communications Board CS1W-SCB21-V1 CS1W-SCB41-V1 CS1 CPU Units CS1 Power Supply Units CS1H-CPU@@H CS1G-CPU@@H C200HW-PA204C C200HW-PA204 C200HW-PA204S C200HW-PA204R C200HW-PA209R C200HW-PD024 C200HW-PD025 CS1 CPU Backplane Programming Devices CX-One (e.g., CX-Programmer) Programming Console Cable for Peripheral Port CPU Rack For both CS1 and C200H Units CS1W-BC@@3 (2, 3, 5, 8, or 10 slots) Cable for Personal Computer CS1W-CN226/626 RUN ERR/ALM INH BKUP PRPHL COMM SYSMAC CS1D-CPU67S PROGRAMMABLE CONTROLLER MCPWR BUSY OPEN or PERIPHERAL For CS1 Unit only CS1W-BC@@2 (2, 3, 5, 8, or 10 slots) Note: Cannot be used for C200H Unit. Programmable Terminal (PT) PORT NS Series Basic I/O Units Special I/O Units CPU Bus Units Memory Card HMC-EF183 CS1 I/O Connecting Cable Expansion Racks CS1W-CN@@3 CS1 Expansion Rack (30 cm, 70 cm, 2 m, 3 m, 5 m, 10 m, 12 m) XW2Z-200T/500T Configuration Units CS1 Expansion Backplanes CS1 I/O Connecting Cable Power Supply Unit CS1 Expansion Rack For both CS1 and C200H Units CS1W-BI@@3 (3, 5, 8, or 10 slots) or Programmable Controllers Power Supply Unit CS1 I/O Connecting Cable CS1 Expansion Rack RS-422A Adapter CJ1W-CIF11 Configuration Units 2 RS-232C Cable for IBM PC/AT or compatible computers XW2Z-200S/500S-CV Configuration Units For CS1 Unit only CS1W-BI@@2 (3, 5, 8, or 10 slots) Note: Cannot be used for C200H Unit. RS-232C Cable for PT CS1G/H Power Supply Unit ■ Configuration Units CS1 Basic I/O Units 8-point Units 16-point Units 32-point Units 64-point Units 96-point Units Input Units --- ● DC Input Unit CS1W-ID211 ● AC Input Unit CS1W-IA@11 ● DC Input Unit CS1W-ID231 ● DC Input Unit CS1W-ID261 ● DC Input Unit CS1W-ID291 ● Transistor Output Units CS1W-OD26@ ● Transistor Output Units CS1W-OD29@ (32 inputs, 32 outputs) ● DC Input/Transistor Output Units CS1W-MD26@ (32 inputs, 32 outputs) ● TTL I/O Unit CS1W-MD561 (48 inputs, 48 outputs) ● DC Input/Transistor Output Units CS1W-MD29@ Output Units ● Triac Output Unit CS1W-OA201 ● Relay Contact Output Unit (independent commons) CS1W-OC201 ● Transistor Output Units ● Transistor Output Units CS1W-OD21@ CS1W-OD23@ ● Triac Output Unit CS1W-OA211 ● Relay Contact Output Unit CS1W-OC211 I/O Units --- --- --- Other Units ● Safety Relay Unit CS1W-SF200 ● Interrupt Input Unit CS1W-INT01 ● Quick-response Input Unit CS1W-IDP01 ● B7A Interface Units (32 inputs) CS1W-B7A12 (32 inputs) CS1W-B7A02 (16 inputs, 16 outputs) CS1W-B7A21 ● B7A Interface Units (32 inputs, 32 outputs) CS1W-B7A22 --- C200H Basic I/O Units and C200H Group-2 High-density I/O Units ● Input Units C200H-I@@@@ (Including group-2 highdensity input units) ● Output Units C200H-O@@@@ (Including group-2 highdensity output units) ● Interrupt Input Unit C200HS-INT01 ● Analog Timer Unit C200H-TM001 ● B7A Interface Units C200H-B7A@@@ CS1 Special I/O Units, CPU Bus Units, and Inner Boards ■ Temperature Sensor Input Units (Process I/O Units) CS1W-PTS@@ ■ Analog Input Units ● Analog Input Units CS1W-AD@@@(-V1) ● Isolated-type DC Input Units (Process I/O Units) CS1W-PDC@@ CS1W-PTW01 CS1W-PTR0@ ■ Analog Output Units ● Analog Output Units CS1W-DA0@@ ● Isolated-type Control Output Units (Process I/O Units) CS1W-PMV0@ ■ Analog I/O Units CS1W-MAD44 ■ Isolated-type Pulse Input Units (Process I/O Units) CS1W-PPS01 ■ Loop Control Board CS1W-LCB0@ ■ High-speed Counter Units CS1W-CT0@@ ■ Customizable Counter Units CS1W-HCP22-V1 CS1W-HCA@2-V1 CS1W-HIO01-V1 ■ Position Control Units CS1W-NC@@3 ■ Position Control Unit with MECHATROLINK-II interface CS1W-NCF71 CS1W-NC@71 ■ Motion Control Units CS1W-MC@21-V1 ■ Motion Control Unit with MECHATROLINK-II interface CS1W-MCH71 ■ I/O Units (Special I/O Units) C200H-ID@@@ C200H-OD@@@ C200H-MD@@@ ■ Temperature Sensor Units C200H-TS@@@ ■ Analog Input Units C200H-AD@@@ ■ Analog Output Units C200H-DA@@@ ■ Analog I/O Units C200H-MAD01 ■ Temperature Control Units C200H-TC@@@ ■ Heat/Cool Control Units C200H-TV@@@ ■ PID Control Units C200H-PID0@ ■ High-speed Counter Units C200H-CT@@@(-V1) ■ Cam Positioner Unit C200H-CP114 ■ Position Control Units C200HW-NC@@3 ■ Motion Control Units C200H-MC221 ■ Serial Communications Units/ Serial Communications Boards CS1W-SCB@1-V1 CS1W-SCU@1-V1 ■ EtherNet/IP Unit CS1W-EIP21 ■ Ethernet Unit CS1W-ETN21 ■ Controller Link Units CS1W-CLK@3 ■ SYSMAC Link Units CS1W-SLK@1 ■ FL-net Unit CS1W-FLN22 ■ DeviceNet Units CS1W-DRM21-V1 ■ CompoNet Master Unit CS1W-CRM21 ■ CompoBus/S Master Unit CS1W-SRM21 ■ ID Sensor Units CS1W-V680C1@ CS1W-V600C1@ ■ GP-IB Interface Unit CS1W-GPI01 ■ High-speed Data Storage Unit CS1W-SPU0@-V2 C200H Special I/O Units ■ DeviceNet Master Unit C200HW-DRM21-V1 ■ CompoBus/S Master Unit C200HW-SRM21-V1 ■ PC Link Unit C200H-LK401 ■ SYSBUS Bus Remote I/O Master Units C200H-RM@@@(-PV1) ■ ID Sensor Units C200H-IDS01-V1 ■ ASCII Units C200H-ASC@@ Note: Including models whose production are discontinued. Programmable Controllers CS1G/H 3 ■ CS1 CPU Rack A CS1 CPU Rack consists of a CPU Unit, Power Supply Unit, and Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus Units). CS1 CPU Backplane CS1W-BC@@@ (See note.) CS1 CPU Unit CS1G/H-CPU@@H Power Supply Unit C200HW-P@@@@(@) RUN ERR/ALM INH BKUP PRPHL COMM SYSMAC CS1D-CPU67S PROGRAMMABLE CONTROLLER MCPWR BUSY OPEN CPU Rack PERIPHERAL PORT Basic I/O Units Special I/O Units CPU Bus Units Note: C200H Units cannot be used on the CPU Rack or Expansion Racks if a CS-series-only CPU Backplane (CS1W-BC@@3) is used. ● Required Units Rack Unit name CPU Rack Required number of units CS1 CPU Backplane (CS1W-BC@@@) 1 Power Supply Unit 1 CPU Unit 1 Maximum Number of Configuration Units Varies by backplane model ● Types of Units In the CS Series, Units are classified into the following three types. The number of Racks differs depending on the type. Type Appearance (example) Basic I/O Units CS1 Basic I/O Units C200H Basic I/O Units Description Unit recognition method No. of Units Units with contact inputs and contact outputs. In the CS1 System, CS1 Basic I/O Units, C200H Basic I/O Units, and Group-2 High-density I/O Units are identified by their mounting positions (Rack and slot). The Units mounted must not exceed the maximum I/O capacity of the CPU Unit. Special I/O Units provide more advanced functions than do Basic I/O Units, including I/O other than contact inputs and contact outputs. Examples of Special I/O Units are Analog I/O Units and High-speed Counter Units. They differ from CPU Bus Units (including Network Communications Units) in having a smaller area for exchanging data with the CPU Unit. Recognized by the CPU Unit according to the unit number (CS-series Special I/O Units: 0 to 95, C200J Special I/O Units: 0 to 9, or 0 to 15) set with the rotary switches on the front panel. CS-series Special I/O Units: 96 Units max.; C200H Special I/O Units: 10 or 16 Units max. (From 1 to 4 unit numbers are assigned per Unit, depending on the model of the Unit.) CPU Bus Units exchange data with the CPU Unit via the CPU Bus. Examples of CPU Bus Units are Network Communications Units and Serial Communications Units. They differ from Special I/O Units in having a larger area for exchanging data with the CPU Unit. Recognized by the CPU Unit according to the unit number (0 to F) set with the rotary switch on the front panel. A maximum of 16 Units can be mounted. C200H Group-2 High-density I/O Units Special I/O Units CS1 Special I/O Units C200H Special I/O Units CPU Bus Units CS1 CPU Bus Units 4 Programmable Controllers CS1G/H ■ CS1 Expansion Racks ● CS1 CPU Racks and Expansion Racks Use this system configuration for an expansion of 12 m or less. Expansion Racks Configuration CPU Rack Unit name CS1 Expansion Backplane CS1W-BI@@@ 12 m CS1 I/O Connecting Cable CS1W-CN@@3 CS1 Expansion Backplane CS1W-BI@@@ CS1 I/O Connecting Cable CS1W-CN@@3 CS1 Expansion Backplane CS1W-BI@@@ CS1 Expansion Rack CS1 Expansion Rack CS1 Expansion Rack Power Supply Unit C200HW-P@@@@(@) Power Supply Unit C200HW-P@@@@(@) The maximum number of Expansion Racks: 7 CS1 I/O Connecting Cable CS1W-CN@@3 Required number of units Expansion Backplane (CS1W-BI@@@) One required for each Expansion Rack Power Supply Unit One required for each Expansion Rack Maximum Number of Configuration Units Varies by backplane model • Cable Cable name Required number of Cables CS1 I/O Connecting Cable (CS1W-CN@@3) One required for each Expansion Rack Power Supply Unit C200HW-P@@@@(@) Programmable Controllers CS1G/H 5 ● When Using a C200HX/HG/HE Expansion I/O Rack It is possible to connect to an existing C200HX/HG/HE Expansion I/O Rack. CS1 CPU Rack, CS1 Expansion Racks, and C200HX/HG/HE Expansion I/O Racks Expansion Racks Configuration • CS1 Expansion Racks CPU Rack Unit name CS1 I/O Connecting Cable CS1W-CN@@3 Power Supply Unit C200HW-P@@@@(@) C200HX/HG/HE Expansion I/O Backplane C200HW-BI@@@ 12 m CS1 to C200H I/O Connecting Cable CS1W-CN@@1 C200HX/HG/HE Expansion I/O Rack Power Supply Unit C200HW-P@@@@(@) C200H I/O Connecting Cable C200H-CN@@1 C200HX/HG/HE Expansion I/O Backplane C200HW-BI@@@ C200HX/HG/HE Expansion I/O Rack Power Supply Unit C200HW-P@@@@(@) The maximum number of Expansion Racks: 7 (C200HX/HG/HE Expansion I/O Racks :3) CS1 Expansion Rack (See note.) CS1 Expansion Backplane CS1W-BI@@@ 1 Power Supply Unit 1 Maximum Number of Configuration Units Varies by backplane model • C200HX/HG/HE Expansion Racks Unit name Required number of units C200HX/HG/HE Expansion I/O Backplane (C200HW-BI@@@) One required for each Expansion Rack Power Supply Unit One required for each Expansion Rack Maximum Number of Configuration Units Varies by backplane model • Cables Cable name Note: Multiple CS1 Expansion Racks can be connected, but the total number of Expansion Racks must not exceed the maximum of 7. In addition, the Racks must be connected in order, with CS1 Expansion Racks connected before C200HX/HG/HE Expansion I/O Racks. Required number of units Expansion Backplane (CS1W-BI@@@) Required number of cables CS1 I/O Connecting Cable (CS1W-CN@@3) Number of CS1 Expansion Racks CS1 to C200H I/O Connecting Cable (CS1W-CN@@1) 1 C200H I/O Connecting Cable (C200H-CN@@1) Number of C200HX/HG/HE Expansion I/O Racks minus 1 CS1 CPU Rack and C200HX/HG/HE Expansion I/O Racks Expansion Racks Configuration • C200HX/HG/HE Expansion I/O Racks CPU Rack Unit name CS1 to C200H I/O Connecting Cable CS1W-CN@@1 C200HX/HG/HE Expansion I/O Backplane C200HW-BI@@@ C200HX/HG/HE I/O Expansion Rack C200HX/HG/HE 12 m Expansion I/O Backplane C200HW-BI@@@ C200H I/O Connecting Cable C200H-CN@@1 C200HX/HG/HE I/O Expansion Rack Power Supply Unit C200HW-P@@@@(@) C200HX/HG/HE Expansion I/O Backplane C200HW-BI@@@ 6 C200H I/O Connecting Cable C200H-CN@@1 C200HX/HG/HE I/O Expansion Rack Power Supply Unit C200HW-P@@@@(@) Programmable Controllers CS1G/H The maximum number of Expansion Racks: 3 Power Supply Unit C200HW-P@@@@(@) Required number of units C200HX/HG/HE Expansion I/O Backplane (C200HW-BI@@@) One required for each Expansion Rack Power Supply Unit One required for each Expansion Rack Maximum Number of Configuration Units Varies by backplane model • Cables Cable name Required number of cables CS1 to C200H I/O Connecting Cable (CS1W-CN@@1) 1 C200H I/O Connecting Cable (C200H-CN@@1) Number of C200HX/HG/HE Expansion I/O Racks minus 1 ● Long-distance Expansion Use this system configuration for an expansion of more 12 m. Expansion is possible by up to 50 m. Using CS1 Connecting Cable and Long-distance Expansion Connecting Cable CPU Rack (Used for long-distance expansion.) CS1 I/O Connecting Cable CS1W-CN@@3 0.7 m CS1 Expansion Backplane CS1W-BI@@@ I/O Control Unit (see note.) CS1W-IC102 CS1 Expansion Rack Power Supply Unit C200HW-P@@@@(@) Connecting Cable for Long-distance Expansion CV500-CN@@2 Connecting Cable for Long-distance Expansion CV500-CN@@2 CS1 Expansion Backplane CS1W-BI@@@ I/O Interface Unit CS1W-II102 CS1 Expansion Rack (Used for long-distance expansion.) CS1 Expansion Backplane CS1W-BI@@@ I/O Interface Unit CS1W-II102 CS1 Expansion Rack (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) CS1 Expansion Backplane CS1W-BI@@@ 50 m Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) Power Supply Unit C200HW-P@@@@(@) 50 m CS1 Expansion Backplane CS1W-BI@@@ CS1 Expansion Backplane CS1W-BI@@@ Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Terminator * Power Supply Unit C200HW-P@@@@(@) Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) * Two Terminators (CV500-TER01) are provided with the CS1W-IC102 I/O Control Unit. The maximum number of Expansion Racks: 6 (In two levels) CS1 Expansion Backplane CS1W-BI@@@ Power Supply Unit C200HW-P@@@@(@) Terminator * Note: If even one Long-distance Expansion Connecting Cable to be used, it is necessary for an I/O Control Unit to be mounted to the CS1 Expansion Rack where the Cable is connected. Expansion Racks Configuration • CS1 Expansion Rack Unit name Required number of units I/O Control Unit (CS1W-IC102) 1 • CS1 Expansion Rack (Long-distance expansion) Unit name Required number of units CS1 Expansion Backplane (CS1W-BI@@@) One required for each Expansion Rack Power Supply Unit One required for each Expansion Rack I/O Interface Unit (CS1W-II102) One required for each Expansion Rack Maximum Number of Configuration Units Varies by backplane model • Cable Cable name Required number of cables CS1 I/O Connecting Cable (CS1W-CN@@3) 1 Connecting Cable for Long-distance Expansion (CV500-CN@@2) Number of CS1 Expansion Racks minus 1 Programmable Controllers CS1G/H 7 Using Long-distance Expansion Connecting Cable I/O Control Unit CS1W-IC102 CPU Rack (Used for long-distance expansion.) Connecting Cable for Long-distance Expansion CV500-CN@@2 Connecting Cable for Long-distance Expansion CV500-CN@@2 CS1 Expansion Backplane CS1W-BI@@@ I/O Interface Unit CS1W-II102 CS1 Expansion Rack (Used for long-distance expansion.) CS1 Expansion Backplane CS1W-BI@@@ I/O Interface Unit CS1W-II102 CS1 Expansion Rack (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) CS1 Expansion Backplane CS1W-BI@@@ Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) 50 m Power Supply Unit C200HW-P@@@@(@) Power Supply Unit C200HW-P@@@@(@) 50 m CS1 Expansion Backplane CS1W-BI@@@ CS1 Expansion Backplane CS1W-BI@@@ Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) CS1 Expansion Backplane CS1W-BI@@@ Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) Connecting Cable for Long-distance Expansion CV500-CN@@2 I/O Interface Unit CS1 Expansion Rack CS1W-II102 (Used for long-distance expansion.) Power Supply Unit C200HW-P@@@@(@) Power Supply Unit C200HW-P@@@@(@) Terminator * The maximum number of Expansion Racks: 7 (In two levels) CS1 Expansion Backplane CS1W-BI@@@ * Two Terminators (CV500-TER01) are provided with the CS1W-IC102 I/O Control Unit. Terminator * CS1 CPU Rack Unit name I/O Control Unit (CS1W-IC102) Required number of units 1 Expansion Racks Configuration • CS1 Expansion Rack (Long-distance expansion) Unit name Required number of units CS1 Expansion Backplane (CS1W-BI@@@) One required for each Expansion Rack Power Supply Unit One required for each Expansion Rack I/O Interface Unit (CS1W-II102) One required for each Expansion Rack Maximum Number of Configuration Units Varies by backplane model • Cable Cable name Connecting Cable for Long-distance Expansion (CV500-CN@@2) 8 Programmable Controllers CS1G/H Required number of cables Number of Long-distance Expansion Racks Dimensions/Mounting Dimensions (Unit: mm) ■ External Dimensions ■ Backplane Mounting Dimensions ● For 2 I/O Slots 4-M4 RUN ERR INH COMM 198.5 POWER SYSMAC C200HX PROGRAMMABLE CONTROLLER CPU64 H B CPU Backplane CS1W-BC023 157 A 145±0.3 D W 172.3±0.3 A B W H D* Note: An Expansion Backplane cannot be connected to a 2-slot CPU Backplane. CS1W-BC022/023 (2 slots) 172.3 145 198.5 157 123 ● For 3, 5, 8, or 10 I/O Slots CS1W-BC032/033 (3 slots) 246 118 260 132 123 Backplane model CS1W-BC052/053 (5 slots) 316 118 330 132 123 CS1W-BC082/083 (8 slots) 421 118 435 132 123 CS1W-BC102/103 (10 slots) 491 118 505 132 123 6 135 (including 132 protrusion) * 118±0.3 CPU Backplane 66 min. * The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit. The depth is 111 mm for the C200HW-PA204C Power Supply Unit. 6 A±0.3 4-M4 A±0.3 80 6 6 135 (including 132 protrusion) * 118±0.3 Expansion Backplane 4-M4 W * The CS1D Backplane has no protrusions. Product name CPU Backplanes CS1 Expansion Backplane Expansion Backplanes C200HX/HG/HE Expansion Backplane Model A W CS1W-BC022/023 (2 slots) 172.3 198.5 CS1W-BC032/033 (3 slots) 246 260 CS1W-BC052/053 (5 slots) 316 330 CS1W-BC082/083 (8 slots) 421 435 CS1W-BC102/103 (10 slots) 491 505 CS1W-BI032/033 (3 slots) 246 260 CS1W-BI052/053 (5 slots) 316 330 CS1W-BI082/083 (8 slots) 421 435 CS1W-BI102/103 (10 slots) 491 505 C200HW-BI031 (3 slots) 175 189 C200HW-BI051 (5 slots) 245 259 C200HW-BI081-V1 (8 slots) 350 364 C200HW-BI101-V1 (10 slots) 420 434 Programmable Controllers CS1G/H 9 ■ Mounting Height The mounted height of CPU Racks, Expansion Racks, and Slave Racks is 118 to 153 mm, depending on I/O Units that are mounted. If Programming Devices or connecting cables are attached, the additional dimensions must be taken into account. Allow sufficient clearance in the control panel in which the PLC is mounted. ● CS1 I/O Connecting Cable R R ≥ 69 mm required Note: Cable thickness: 8.6 mm dia. ● C200H I/O Connecting Cable 118 mm to 153 mm 180 mm to 223 mm Note: When using Expansion Racks, the total length of the I/O Connecting Cables must be less than 12 m. When bending an I/O Connecting Cables, provide at least the minimum bending radius shown in the following diagrams. R ≥ 41 mm required R Note: Cable thickness: 5.1 mm dia. ● CS1 to C200H I/O Connecting Cable R R ≥ 41 mm required Note: Cable thickness: 5.1 mm dia. ● Connecting Cable for Long-distance Expansion R R ≥ 80 mm required Note: Cable thickness: 10 mm dia. 10 Programmable Controllers CS1G/H General Specifications Specifications Power Supply Unit model C200HW-PA204 C200HW-PA204C C200HW-PA204R C200HW-PA204S C200HW-PA209R C200HW-PD024 C200HW-PD025 Item Power supply voltage 100 to 240 VAC (wide range), 50/60 Hz *1 100 to 120 VAC/200 to 240 V, 50/60 Hz 24 VDC Operating voltage range 85 to 264 VAC 85 to 132 VAC/170 to 264 V 19.2 to 28.8 VDC Power consumption 120 VA max. Inrush current 120 VA max. 100 to 120 VAC input 15 A/8 ms max. (cold start at room temperature) 200 to 240 VAC input 30 A/8 ms max. (cold start at room temperature) 20 MΩ min. (at 500 VDC) between AC Insulation resistance external and GR terminals *2 Dielectric strength 100 VA max. 2,300 VAC 50/60 Hz for 1 min between AC external and GR terminals *2 Leakage current: 10 mA max. 100 to 120 VAC input 20 A/8 ms max. (cold start at room temperature) 200 to 240 VAC input 30 A/8 ms max. (cold start at room temperature) 180 VA max. 40 W max. 100 to 120 VAC: 30 A max. 200 to 240 VAC: 40 A max. 30 A max. • 20 MΩ min. (at 500 VDC) between all AC external terminals and GR terminal and between all alarm output terminals. • 20 MΩ min. (at 250 VDC) between all alarm output terminals and GR terminal. 20 MΩ min. (at 500 VDC) between all AC external and GR terminals *2 • 2,300 VAC, 50/60 Hz for 1 minute between all AC external terminals and GR terminal and between all alarm output terminals. Leakage current: 10 mA max. • 1,000 VAC, 50/60 Hz for 1 minute between all alarm output terminals and GR terminal. Leakage current: 10 mA max. 2,300 VAC 50/60 Hz for 1 min between all AC external and GR terminals *2 Leakage current: 10 mA max. 60 W max. 20 MΩ min. (at 500 VDC) between all DC external and GR terminals *2 1,000 VAC 50/60 Hz for 1 min between all DC external and GR terminals *2 Leakage current: 10 mA max. 1,000 VAC 50/60 Hz for 1 min between all DC external and GR terminals *2 Leakage current: 10 mA max. Noise immunity 2 kV on power supply line (conforming to IEC61000-4-4) Vibration resistance Conforms to JIS 0040, 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes (Time coefficient: 8 minutes x coefficient factor 10 = total time 80 min.) (CPU Unit mounted to a DIN track: 2 to 55 Hz, 2.9 m/s2 in X, Y, and Z directions for 20 minutes) Shock resistance Conforms to JIS 0041, 147 m/s2 3 times each in X, Y, and Z directions Ambient operating temperature 0 to 55°C Ambient operating humidity 10% to 90% (with no condensation) Ambient operating atmosphere No corrosive gases Ambient storage temperature -20 to 75°C (excluding battery) Grounding Less than 100 Ω Enclosure Mounted in a panel. Weight Each Rack: 6 kg max. CPU Rack dimensions (mm) 2 slots: 3 slots: 5 slots: 8 slots: 10 slots: Standards Conforms to UL, CSA, cULus, NK, Lloyds, and EC Directives. *1. *2. *3. *4. 10% to 90% (with no condensation) *4 10% to 90% (with no condensation) 198.5 x 157 x 123 (W x H x D) *3 260 x 130 x 123 (W x H x D) *3 330 x 130 x 123 (W x H x D) *3 435 x 130 x 123 (W x H x D) *3 505 x 130 x 123 (W x H x D) *3 C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz. Disconnect the Power Supply Unit’s LG terminal from the GR terminal when testing insulation and dielectric strength. Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit. The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit. The depth is 111 mm for the C200HW-PA204C Power Supply Unit. Maintain an ambient storage temperature of -25 to 30°C and relative humidity of 25% to 70% when storing the C200HW-PA204C for longer than 3 months to keep the replacement notification function in optimum working condition. Programmable Controllers CS1G/H 11 Common Specifications for CPU Units Item Specifications Control method Stored program I/O control method Cyclic scan and immediate processing are both possible. Programming •Ladder diagrams •SFC (sequential function charts) •ST (structured text) •Mnemonics Instruction length 1 to 7 steps per instruction Ladder instructions Approx. 400 (3-digit function codes) Execution time Basic instructions 0.02 μs min. Special instructions 0.04 μs min. Number of tasks 288 (cyclic tasks: 32, interrupt tasks: 256) Note 1:Cyclic tasks are executed each cycle and are controlled with TKON(820) and TKOF(821) instructions. 2:The following 4 types of interrupt tasks are supported. Power OFF interrupt tasks: 1 max. Scheduled interrupt tasks: 2 max. I/O interrupt tasks: 32 max. External interrupt tasks: 256 max. Interrupt types Scheduled Interrupts: Interrupts generated at a time scheduled by the CPU Unit’s built-in timer. I/O Interrupts: Interrupts from Interrupt Input Units. Power OFF Interrupts: Interrupts executed when the CPU Unit’s power is turned OFF. External I/O Interrupts: Interrupts from the Special I/O Units, CS-series CPU Bus Units, or the Inner Board. Function blocks *1 Languages in function block definitions: ladder programming, structured text CIO (Core I/O) Area I/O Area 5,120: CIO 000000 to CIO 031915 (320 words from CIO 0000 to CIO 0319) The setting of the first word can be changed from the default (CIO 0000) so that CIO 0000 to CIO 0999 can be used. I/O bits are allocated to Basic I/O Units, such as CS-series Basic I/O Units, C200H Basic I/O Units, and C200H Group-2 High-density I/O Units. Link Area 3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to CIO 1199) Link bits are used for data links and are allocated to Units in Controller Link Systems and PLC Link Systems. CPU Bus Unit Area 6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to CIO 1899) CS-series CPU Bus Unit bits store the operating status of CS-series CPU Bus Units. (25 words per Unit, 16 Units max.) Special I/O Unit Area 15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000 to CIO 2959) Special I/O Unit bits are allocated to CS-series Special I/O Units and C200H Special I/O Units. (See Note.) (10 words per Unit, 96 Units max. The maximum total number of slots, however, is limited to 80 including expansion slots, so the maximum number of Units is actually 80. Note: A maximum of 16 C200H Special I/O Units can be mounted. Also, depending on the Units, the maximum may be 10. Some I/O Units are classified as Special I/O Units. Inner Board Area 1,600 (100 words): CIO 190000 to CIO 199915 (words CIO 1900 to CIO 1999) Inner Board bits are allocated to Inner Boards. (100 I/O words max.) SYSMAC BUS Area 800 (50 words): CIO 300000 to CIO 304915 (words CIO 3000 to CIO 3049) SYSMAC BUS bits are allocated to Slave Racks connected to SYSMAC BUS Remote I/O Master Units. (10 words per Rack, 5 Racks max.) I/O Terminal Area 512 (32 words): CIO 310000 to CIO 313115 (words CIO 3100 to CIO 3131) I/O Terminal bits are allocated to I/O Terminal Units (but not to Slave Racks) connected to SYSMAC BUS Remote I/O Master Units. (1 word per Terminal, 32 Terminals max.) C200H Special I/O Unit Area 8,192 bits (512 words): W00000 to W51115 (W000 to W511) C200H Special I/O Unit bits are allocated to C200H Special I/O Units, and accessed separately from I/O refreshing. DeviceNet Area 1,600 (100 words): Outputs: CIO 005000 to CIO 009915 (words CIO 0050 to CIO 0099) Inputs: CIO 035000 to CIO 039915 (words CIO 0350 to CIO 0399) DeviceNet bits are allocated to Slaves according to DeviceNet remote I/O communications. PLC Link Area 64 bits (4 words): CIO 024700 to CIO 025015 (words CIO 0247 to CIO 0250) When a PLC Link Unit is used in a PLC Link, use these bits to monitor PLC Link errors and the operating status of other CPU Units in the PLC Link. The CIO Area can be used as work bits if the bits are not used as shown here. Internal I/O Area 4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499) 37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to CIO 6143) These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.) Work Area 8,192 bits (512 words): H00000 to H51115 (H000 to H511) These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.) When using work bits in programming, use the bits in the Work Area first before using bits from other areas. Holding Area 8,192 bits (512 words): H00000 to H51115 (H000 to H511) Holding bits are used to control the execution of the program, and maintain their ON/OFF status when the PLC is turned OFF or the operating mode is changed. Note: The Function Block Holding Area words are allocated from H512 to H1535. These words can be used only for the function block instance area (internally allocated variable area). Auxiliary Area Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447) Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959) Auxiliary bits are allocated specific functions. Temporary Area 16 bits (TR0 to TR15) Temporary bits are used to temporarily store the ON/OFF execution conditions at program branches. Timer Area 4,096: T0000 to T4095 (separate from counters) Note: The time units for timer settings are 0.1 s, 0.01 s, and 0.001 s (depending on the timer instruction that is used). Counter Area C0000 to C4095 (separate from timers) DM Area 32K words: D00000 to D32767 Internal Special I/O Unit DM Area: D20000 to D29599 (100 words x 96 Units) Used to set parameters for Special I/O Units. CPU Bus Unit DM Area: D30000 to D31599 (100 words x 16 Units) Used to set parameters for CPU Bus Units. Inner Board DM Area: D32000 to D32099 Used to set parameters for Inner Boards. Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the DM Area maintain their status when the PLC is turned OFF or the operating mode is changed. 12 Programmable Controllers CS1G/H Item Specifications EM Area 32K words per bank, 13 banks max.: E0_00000 to EC_32767 max. (Varies by CPU Unit model.) Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the EM Area maintain their status when the PLC is turned OFF or the operating mode is changed. The EM Area is divided into banks, and the addresses can be set by either of the following methods. Changing the current bank using the EMBC(281) instruction and setting addresses for the current bank. Setting bank numbers and addresses directly. EM data can be stored in files by specifying the number of the first bank. Data Registers DR0 to DR15: Store offset values for indirect addressing. One register is 16 bits (1 word). Index Registers IR0 to IR15: Store PLC memory addresses for indirect addressing. One register is 32 bits (2 words). Task Flag Area 32 (TK0000 to TK0031): Task Flags are read-only flags that are ON when the corresponding cyclic task is executable and OFF when the corresponding task is not executable or in standby status. Trace Memory 4,000 words (The maximum amount of data that can be traced in a data trace is 500 samples for 31 bits and 6 words. File Memory Memory Cards: Compact flash memory cards can be used (MS-DOS format). EM file memory: Part of the EM Area can be converted to file memory (MS-DOS format). Parallel Processing Modes Program execution and peripheral servicing can be performed simultaneously. Battery-free operation The user program and the system’s parameters are backed up automatically in flash memory, which is standard equipment. Constant cycle time Possible (1 to 32,000 ms) (Unit: 1 ms) Cycle time monitoring Possible (Unit stops operating if the cycle is too long): 10 to 40,000 ms (Unit: 10 ms) I/O refreshing Cyclic refreshing, immediate refreshing, refreshing with I/O REFRESH instruction I/O memory holding when changing operating modes Possible (Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.) Load OFF All outputs on Output Units can be turned OFF. Input response time setting Time constants can be set for inputs from Basic I/O Units. The time constant can be increased to reduce the influence of noise and chattering or it can be decreased to detect shorter pulses on the inputs (CS1 Basic I/O Units only). Startup mode setting Supported. Automatically reading programs (autoboot) from the Memory Card when the power is turned ON. Memory Card functions Format in which data is stored in Memory Card User program: Program file format PLC Setup and other parameters: Data file format (binary format) I/O memory: Data file format (binary format), text format, or CSV format Functions for which Memory Card read/write is supported User program instructions, Programming Devices (including Programming Consoles), Host Link computers Filing Memory Card data and the EM (Extended Data Memory) Area can be handled as files. Debugging Control set/reset, differential monitoring, data tracing (scheduled, each cycle, or when instruction is executed), storing location generating error when a program error occurs Online editing User programs can be overwritten in program-block units when the CPU Unit is in MONITOR or PROGRAM mode. (This function is not available for block programming areas.) Program protection Overwrite protection: Set using DIP switch. Copy protection: Password set using Programming Device. Error check User-defined errors (i.e., user can define fatal errors and non-fatal errors) The FPD(269) instruction can be used to check the execution time and logic of each programming block. Error log Up to 20 errors are stored in the error log. Information includes the error code, error details, and the time the error occurred. Functions Serial communications Built-in peripheral port: Programming Device (including Programming Console) connections, Host Links, NT Links Built-in RS-232C port: Programming Device (excluding Programming Console) connections, Host Links, no-protocol communications, NT Links, and Serial Gateway *3 Serial communications board (order separately): protocol macros, Host Links, no-protocol communications *3, NT Links, Serial Gateway *3, and Modbus-RTU Slave *5 Clock Provided on all models. Note: Used to store the time when power is turned ON and when errors occur. Power OFF detection time 10 to 25 ms (not fixed) Power OFF detection delay time 0 to 10 ms (user-defined, default: 0 ms) Memory retention during power interruptions Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of the counter Completion Flags and present values. Note: If the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to maintain the IOM Hold Bit status when power to the PLC is turned ON, the contents of the CIO Area, the Work Area, part of the Auxiliary Area, timer Completion Flags and PVs, Index Registers, and the Data Registers will be saved. Sending commands to a Host Link computer FINS commands can be sent to a computer connected via the Host Link System by executing Network Communications Instructions from the PLC. Remote programming and monitoring Host Link communications can be used for remote programming and remote monitoring through a Controller Link System or Ethernet network. 8-level communications *2 Remote programming and monitoring across up to eight network layers (Controller Link or Ethernet) by using Host Link. (They are possible between different types of networks.) Storing comments in CPU Unit I/O comments can be stored in the CPU Unit in Memory Cards *1 or EM file memory. Program check Program checks are performed at the beginning of operation for items such as no END instruction and instruction errors. Programming Devices (except for the Programming Consoles) can also be used to check programs. RUN output: The internal contacts will be ON (closed) while the CPU Unit is operating in RUN mode or MONITOR mode. Control output signals These terminals are provided only on C200HW-PA204R, C200HW-PA209R, and CS1D-PA207R Power Supply Units. *1. *2. *3. *4. *5. Battery service life The battery life is 5 years at an ambient temperature of 25°C, although the lifetime can be as short as 1.1 years under adverse temperature and power conditions. (Battery Set: CS1W-BAT01) *3 *4 Self-diagnostics CPU errors (watchdog timer), I/O verification errors, I/O bus errors, memory errors, and battery errors. Other functions Words in the Auxiliary Area store the number of power interruptions, time of the last power interruption, and total power ON time. CPU Units with unit version 3.0 or later only. CPU Units with unit version 2.0 or later only. (Communications across three network layers is supported for Pre-Ver. 2.0 CPU Units.) CPU Units with unit version 3.0 or later only or Serial Communications Board/Unit with unit version 1.2 or later only. Use a replacement battery that was manufactured within the last two years. Serial Communications Board/Unit with unit version 1.3 or later only. Programmable Controllers CS1G/H 13 ■ Functions Added by Unit Version The following functions have been added for the unit versions of CS1G/H CPU Units. OK: Supported, ---: Not supported Model Function Unit version CS1@-CPU@@H No unit version Unit version 2.0 Unit version 3.0 Unit version 4.0 Downloading and Uploading Individual Tasks --- OK OK OK Improved Read Protection Using Passwords --- OK OK OK Write Protection from FINS Commands Sent to CPU Units via Networks --- OK OK OK Online Network Connections without I/O Tables --- OK OK OK Communications through a Maximum of 8 Network Levels --- OK OK OK OK (from lot number 030201) OK OK OK OK (for up to 8 group) OK (for up to 64 group) OK (for up to 64 group) OK Automatic Transfers at Power ON without a Parameter File (.STD) --- OK OK OK Automatic Detection of I/O Allocation Method for Automatic Transfer at Power ON --- --- --- OK Operation Start/End Times Connecting Online to PLCs via NS-series PTs Setting First Slot Words Support of new instructions --- OK OK OK MILH, MILR, MILC --- OK OK OK = DT, DT, DT, > = DT --- OK OK OK BCMP2 --- OK OK OK GRY OK (from lot number 030201) OK OK OK TPO --- OK OK OK DSW, TKY, HKY, MTR, 7SEG --- OK OK OK EXPLT, EGATR, ESATR, ECHRD, ECHWR --- OK OK OK OK (from lot number 030418) OK OK OK IORD/IOWR reading/writing to CPU Bus Units --- --- --- OK Function blocks (CX-Programmer Ver.5.0 or later) PRV2 --- --- OK OK Serial Gateway (converting FINS commands to CompoWay/ F commands at the built-in serial port) --- --- OK OK Comment memory (in internal flash memory) --- --- OK OK Expanded simple backup data --- --- OK OK TXDU(256), RXDU(255) (support no-protocol communications with Serial Communications Units with unit version 1.2 or later) --- --- OK OK Model conversion instructions: XFERC(565), DISTC(566), COLLC(567), MOVBC(568), BCNTC(621) --- --- OK OK Special function block instructions: GETID(286) --- --- OK OK Additional instruction functions TXD(236), RXD(235) (support no-protocol communications with Serial Communications Units with unit version 1.2 or later) --- --- OK OK Conversion instructions from numbers to ASCII and ASCII to numbers --- --- --- OK Flowchart conversion instructions (one type of block programming instructions) to convert flowchart programs from C-series Flowchart PLCs to ladder programs for CS/CJ-series PLCs --- --- --- OK Online editing of function blocks --- --- --- OK Support for I/O variables (including array variables for I/O variables) --- --- --- OK Support for STRING data type and processing functions for ST language. --- --- --- OK Use of new special instructions Function block (FB) functional upgrades ● Unit Versions Unit versions have been introduced to control differences in functions featured by CPU Units that are the result of version upgrades. The unit version is marked on the nameplates of products subject to version control, as shown in the diagram. Unit Unit version ■ Unit Versions and Programming Devices Applicable PLCs CS1G/H-series 14 Name CS1H-CPU67H/66H/65H/64H/63H CS1G-CPU45H/44H/43H/42H Programmable Controllers CX-Programmer No unit version Version 2.1 or later Unit version 2.0 Version 4.0 or later Unit version 3.0 Version 5.0 or later Unit version 4.0 Version 7.0 or later CS1G/H Current Consumption for Power Supply Units ■ Checking Current Consumption and Power Consumption After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack. Condition 1: Current Requirements There are three voltage groups for internal power consumption: 5 V, 26 V, and 24 V. • Current consumption at 5 V (internal logic power supply) • Current consumption at 26 V (relay driving power supply) • Current consumption at 24 V (power supply output terminals) (C200HW-PA204S only) Condition 2: Power Requirements For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables. ● CPU Racks and Expansion Racks The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below. Note 1:For CPU Racks, include the CPU Backplane and CPU Unit current and power consumption in the calculations. 2: For Expansion Racks, include the Expansion Backplanes current and power consumption in the calculations. Max. current supplied (A) 5 V (B) 26 V (C) 24 V (D) Max. total power supplied C200HW-PA204C 4.6 A 0.6 A --- 30 W C200HW-PA204 4.6 A 0.6 A --- 30 W C200HW-PA204S 4.6 A 0.6 A 0.8 A 30 W C200HW-PA204R 4.6 A 0.6 A --- 30 W 45 W Power Supply Units C200HW-PA209R 9A 1.3 A --- C200HW-PD024 4.6 A 0.6 A --- 30 W C200HW-PD025 5.3 A 1.3 A --- 40 W 7A 1.3 A --- 35 W 4.3 A 0.56 A --- 28 W CS1D-PA207R CS1D-PD024 Conditions 1 and 2 below must be satisfied. Condition 1: Maximum Current (1) Total Unit current consumption at 5 V ≤ (A) value (2) Total Unit current consumption at 26 V ≤ (B) value (3) Current consumption for service power supply at 24 V ≤ (C) value (Only when using the service power supply from the C200HW-PA204S.) Condition 2: Maximum Power (1) x 5 V + (2) x 26 V + (3) x 24 V ≤ (D) value ■ Example: Calculating Total Current and Power Consumption Example: When the Following Units are Mounted to a CS-series CPU Rack Using a CS1W-PA204S Power Supply Unit Type Model Quantity CPU Backplanes (8 slots) CS1W-BC083 CPU Unit Input Unit Voltage group 5V 26 V 24 V 1 0.11 A --- --- CS1H-CPU67H 1 0.82 A --- --- CS1W-ID211 2 0.10 A --- ----- CS1W-ID291 2 0.20 A --- Output Unit CS1W-OC201 2 0.10 A 0.048 A --- Special I/O Unit CS1W-NC213 1 0.25 A --- --- CPU Bus Unit CS1W-CLK23 1 0.33 A --- --- 0.3 A used --- --- 0.3 A 0.11 A + 0.82 A + 0.10 A x 2 + 0.20 A x 2 + 0.10 A x 2 + 0.25 A + 0.33 A 0.048 A x 2 0.3 A Service power supply Current consumption Power consumption Total Result 2.31 A (≤ 4.6 A) 0.096 A (≤ 0.6 A) 0.3 A (≤ 0.8 A) Total 2.31 A x 5 V=11.55 W 0.096 A x 26 V=2.496 W 0.3 A x 24 V=7.2 W Result 11.55 + 2.496 + 7.2 = 21.246W (≤ 30W) Note: For details on Unit current consumption, refer to Ordering Information. Programmable Controllers CS1G/H 15 ■ Using the CX-Programer to Display Current Consumption and Width CPU Rack and Expansion Rack current consumption and width can be displayed by selecting Current Consumption and Width from the Options Menu in the CS1 Table Window. If the capacity of the Power Supply Unit is exceeded, it will be displayed in red characters. Example: Current consumption at 5 V Power Supply Current Total current Long-distance Unit model expansion consumption consumption at 26 V/24 V 16 Programmable Controllers CS1G/H Width Ordering Information Basic Configuration Units ................................................................................18 Programming Devices...................................................................................... 22 Accessories and Maintenance Parts ...............................................................25 DIN Track Mounting Accessories .....................................................................25 Basic I/O Units .................................................................................................26 Special I/O Units, CPU Bus Units, and Inner Boards ......................................32 Replacing C200H I/O Units ..............................................................................49 Ordering Information ● Applicable Standards Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model. ● EU Directives The EU Directives applicable to PLCs include the EMC Directives and the Low Voltage Directive. OMRON complies with these directives as described below manufacturing installations. ● EMC Directives Applicable Standards EMI: EN61000-6-4 EN61131-2 EMS: EN61000-6-2 EN61131-2 OMRON PLCs conform to the related EMC standards so that the devices and machines into which they are built can more easily conform to EMC standards. The actual PLCs have been checked for conformity to EMC standards. Whether these standards are satisfied for the actual system, however, must be checked by the customer. EMC-related performance will vary depending on the configuration, wiring, and other conditions of the equipment or control panel in which the PLC is installed. The customer must, therefore, perform final checks to confirm that the overall machine or device conforms to EMC standards. ● Low Voltage Directive Applicable Standard: EN61131-2 Devices that operate at voltages from 50 to 1,000 VAC or 75 to 150 VDC must satisfy the appropriate safety requirements. With PLCs, this applies to Power Supply Units and I/O Units that operate in these voltage ranges. These Units have been designed to conform to EN61131-2, which is the applicable standard for PLCs. 17 Ordering Information Basic Configuration Units CPU Rack ■ CS1 CPU Units Mountable Racks Specifications CS1 CPU Rack Product name Number of Program I/O points capacity CS1 CPU Units Data memory capacity LD instruction execution time Online Unit replacement Duplex Communications Units Duplex Power Supply Units CS-series CPU Backplane CS1W-BC@@2 CS1D CPU Rack Current consumption (A) CS1D CPU CS/C200HBackplane 5V 26 V series CPU CS1D-BC082S system system Backplane or CS1W-BC@@3 CS1D-BC052 Model 448K words 5,120 (DM: 32K words, (Expansion 250K steps EM: 32K words × Racks: 7) 13 banks) * 0.82 --- CS1H-CPU67H 256K words 5,120 (DM: 32K words, (Expansion 120K steps EM: 32K words × Racks: 7) 7 banks) * 0.82 --- CS1H-CPU66H * 0.82 --- CS1H-CPU65H * 0.82 --- CS1H-CPU64H * 0.82 --- CS1H-CPU63H 5,120 (Expansion 60K steps Racks: 7) 128K words (DM: 32K words, EM: 32K words × 3 banks) 5,120 (Expansion 30K steps Racks: 7) 64K words (DM: 32K words, EM: 32K words × 1 bank) 5,120 (Expansion 20K steps Racks: 7) 64K words (DM: 32K words, EM: 32K words × 1 bank) 5,120 (Expansion 60K steps Racks: 7) 128K words (DM: 32K words, EM: 32K words × 3 banks) * 0.78 --- CS1G-CPU45H 1,280 (Expansion 30K steps Racks: 3) 64K words (DM: 32K words, EM: 32K words × 1 bank) * 0.78 --- CS1G-CPU44H 960 (Expansion 20K steps Racks: 2) 64K words (DM: 32K words, EM: 32K words × 1 bank) * 0.78 --- CS1G-CPU43H 960 (Expansion 10K steps Racks: 2) 64K words (DM: 32K words, EM: 32K words × 1 bank) * 0.78 --- CS1G-CPU42H 0.02 µs No No No Yes 0.04 µs No No Yes No No * These values include the current consumption of a connected Programming Console. NT-AL001 Link Adapters consume an additional 0.15 A each when used. 18 Programmable Controllers CS1G/H ■ Power Supply Units One Power Supply Unit is required for each Rack. Output capacity Product name AC Power Supply Unit Power supply voltage 100 to 240 VAC (wide range) AC Power 100 to 240 Supply VAC Unit (wide range) * 100 to 120 VAC or 200 to 240 VAC DC Power Supply Unit 5-VDC Model 26-VDC Standards output output capacity capacity Options 24-VDC Total 0.8 A power con- service sumption power supply RUN output Mountable Racks Maintenance forecast monitor C200HX/ CS1 LongCS1 CS1D CPU HG/HE distance ExpanCPU Rack Expansion Expansion sion Rack Rack I/O Rack Rack CS1D Expansion Rack SYSMAC BUS Slave Rack Model Yes C200HW-PA204C No C200HW-PA204 No C200HW-PA204R 4.6 A 0.625 A 30 W No No 4.6 A 0.625 A 30 W No Yes 0.625 A (with 0.8 A, 24 VDC service power supply) 30 W Yes No No 9A 1.3 A 45 W No Yes No C200HW-PA209R 4.6 A 0.625 A 30 W No No No C200HW-PD024 5.3 A 1.3 A 40 W No No No C200HW-PD025 4.6 A Yes No Yes C200HW-PA204S 24 VDC * C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz. ■ CS1 CPU Backplane Mountable configuration units Product name Specifications Applicable CPU CS-series Unit Basic I/O Unit Basic I/O Units Special I/O Units C200H Group-2 CS-series Special I/O Highdensity I/O Unit Unit C200Hseries Basic I/O Unit Current consumption (A) CPU Bus Units C200HCS-series series CPU Bus Special I/O Unit Unit Model 5V 26 V system system 2 slots (Note: Expansion Racks cannot be connected.) For CS-series Unit only Note: C200Hseries Units 3 slots cannot be 5 slots mounted. 8 slots 10 slots CS1 CPU Backplane For both CS/ C200H-series Units 2 slots (Note: Expansion Racks cannot be connected.) Yes No Yes No Yes CS1 CPU Unit Yes 3 slots 0.11 --- CS1W-BC022 0.11 --- CS1W-BC032 0.11 --- CS1W-BC052 0.11 --- CS1W-BC082 0.11 --- CS1W-BC102 0.11 --- CS1W-BC023 0.11 --- CS1W-BC033 5 slots 0.11 --- CS1W-BC053 8 slots 0.11 --- CS1W-BC083 10 slots 0.11 --- CS1W-BC103 2 slots (CS1W-BC022/023): 3 slots (CS1W-BC032/033): Dimensions (mm) 5 slots (CS1W-BC052/053): 8 slots (CS1W-BC082/083): 10 slots (CS1W-BC102/103): 198.5 x 157 (W x H) 260 x 132 (W x H) 330 x 132 (W x H) 435 x 132 (W x H) 505 x 132 (W x H) Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2). 2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2). Programmable Controllers CS1G/H 19 Expansion Racks Select the Backplane, Power Supply Unit, and Expansion Cable. If the expansion length is more than 12 m, an I/O Interface Unit is also required. ■ Expansion Backplanes ● Normal Expansion (Not Long-distance Expansion) Mountable configuration units Basic I/O Units Product name Specifications CS-series Basic I/O Unit 3 slots For CS-series Unit only 5 slots Note: C200H-series Units cannot be 8 slots mounted. 10 slots CS1 Expansion Backplanes For both CS/C200Hseries Units Dimensions (mm) Dimensions (mm) C200H Group-2 Highdensity I/O Unit CS-series Special I/O Unit C200Hseries Special I/O Unit Current consumption (A) Model CS-series CPU Bus Unit 5V 26 V system system 0.23 --- CS1W-BI032 0.23 --- CS1W-BI052 0.23 --- CS1W-BI082 0.23 --- CS1W-BI102 3 slots 0.23 --- CS1W-BI033 5 slots 0.23 --- CS1W-BI053 8 slots 0.23 --- CS1W-BI083 10 slots 0.23 --- CS1W-BI103 0.15 --- C200HW-BI031 0.15 --- C200HW-BI051 0.15 --- C200HW-BI081-V1 0.15 --- C200HW-BI101-V1 No No No Yes Yes Yes 3 slots (CS1W-BCI032/033): 5 slots (CS1W-BI052/053): 8 slots (CS1W-BI082/083): 10 slots (CS1W-BI102/103): 3 slots For C200H-series Unit only 5 slots Note: CS-series Units 8 slots cannot be mounted. 10 slots C200HX/HG/HE Expansion I/O Backplane C200Hseries Basic I/O Unit CPU Bus Units Special I/O Units No Yes Yes 260 x 132 (W x H) 330 x 132 (W x H) 435 x 132 (W x H) 505 x 132 (W x H) Yes 3 slots (C200HW-BI031): 5 slots (C200HW-BI051): 8 slots (C200HW-BI081-V1): 10 slots (C200HW-BI101-V1): Yes Yes No Yes No 189 x 132 (W x H) 259 x 132 (W x H) 364 x 132 (W x H) 434 x 132 (W x H) ● Long-distance Expansion Mountable configuration units Basic I/O Units Product name CS1 Expansion Backplanes Specifications 3 slots For CS-series Unit only 5 slots Note: C200H-series Units cannot be 8 slots mounted. 10 slots For both CS/C200Hseries Units CPU Unit mounted to CPU C200HBackplane CS-series series Basic I/O Basic I/O Unit Unit C200H Group-2 Highdensity I/O Unit Special I/O Units C200HCS-series series Special Special I/O Unit I/O Unit CPU Bus Units Current consumption (A) Model CS-series 5V 26 V CPU Bus system system Unit 0.23 --- CS1W-BI032 0.23 --- CS1W-BI052 0.23 --- CS1W-BI082 0.23 --- CS1W-BI102 3 slots 0.23 --- CS1W-BI033 5 slots 0.23 --- CS1W-BI053 8 slots 0.23 --- CS1W-BI083 10 slots 0.23 --- CS1W-BI103 CS1 CPU Unit Yes No Yes No Yes * * CS-series CPU Bus Units can be mounted in a Long-distance Expansion Rack, but the I/O refreshing time is longer than it is when the CPU Bus Unit is mounted in the CPU Rack. Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2). 2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2). 20 Programmable Controllers CS1G/H ■ I/O Control Unit (Required for long-distance expansion) The CS1W-IC102 I/O Control Unit is mounted to a CPU Backplane or CS1 Expansion Backplane when expanding more than 12 m. A CV500-CN@@2 Long-distance Expansion Connecting Cable is used to connect the I/O Control Unit to a CS1W-II102 I/O Interface Unit. Current consumption (A) Mountable backplanes Product name Specifications CPU CS1 Expansion backplane Backplanes I/O Control Unit Required to expand more than 12 m. (Two CV500-TER01 Terminators are included.) Connecting cable: Connecting Cable for Long-distance Expansion CV500-CN@@2 Connecting unit: Interface Unit CS1W-II102 Yes 5V system 26 V system 0.92 --- Yes Model CS1W-IC102 ■ I/O Interface Unit (Required for long-distance expansion) The CS1W-II102 I/O Interface Unit is mounted to a CS1 Expansion Backplane and connected to a CV500-CN@@2 Long-distance Expansion Connecting Cable when expanding more than 12 m. Product name Current consumption (A) Specifications 5V system 24 V system 0.23 --- Model I/O Interface Unit Required to expand more than 12 m. Mountable backplane: CS1 Expansion Backplanes Connecting cable: Connecting Cable for Long-distance Expansion CV500-CN@@2 CS1W-II102 ■ Connecting Cables for Expansion Backplanes Product name Specifications Model CS1 I/O Connecting Cables Connects a CPU Backplane or CS1 Expansion Backplane to a CS1 Expansion Backplane. CS1 to C200H I/O Connecting Cables Connects a CPU Backplane or CS1 Expansion Backplane to a C200HX/HG/HE Expansion I/O Backplane. C200H I/O Connecting Cables Connects a C200HX/HG/HE Expansion I/O Backplane to a C200HX/HG/HE Expansion I/O Backplane. Cable length: 0.3 m CS1W-CN313 Cable length: 0.7 m CS1W-CN713 Cable length: 2 m CS1W-CN223 Cable length: 3 m CS1W-CN323 Cable length: 5 m CS1W-CN523 Cable length: 10 m CS1W-CN133 Cable length: 12 m CS1W-CN133-B2 Cable length: 0.3 m CS1W-CN311 Cable length: 0.7 m CS1W-CN711 Cable length: 2 m CS1W-CN221 Cable length: 3 m CS1W-CN321 Cable length: 5 m CS1W-CN521 Cable length: 10 m CS1W-CN131 Cable length: 12 m CS1W-CN131-B2 Cable length: 0.3 m C200H-CN311 Cable length: 0.7 m C200H-CN711 Cable length: 2 m C200H-CN221 Cable length: 5 m C200H-CN521 Cable length: 10 m C200H-CN131 Cable length: 0.3 m CV500-CN312 Cable length: 0.6 m CV500-CN612 Cable length: 1 m CV500-CN122 Cable length: 2 m CV500-CN222 Cable length: 3 m CV500-CN322 Cable length: 5 m CV500-CN522 Cable length: 10 m CV500-CN132 Cable length: 20 m CV500-CN232 Cable length: 30 m CV500-CN332 Cable length: 40 m CV500-CN432 Cable length: 50 m CV500-CN532 ■ Connecting Cables for Long-distance Expansion Product name Specifications Model Connecting Cables for Long-distance Expansion Connects a Long-distance I/O Control Unit to an I/O Interface Unit. Reading the production number @@@@ Year (e.g., 1997=7) Month (1 to 9, X (10), Y (11), Z (12)) Day (01 to 31) Programmable Controllers CS1G/H 21 Programming Devices ■ Support Software Product name Specifications Number of Model Standards licenses --- (Media only) * FA Integrated Tool Package CX-One Ver.4.@ DVD CXONE-AL00D-V4 DVD CXONE-AL01D-V4 DVD CXONE-AL03D-V4 DVD CXONE-AL10D-V4 30 licenses DVD CXONE-AL30D-V4 50 licenses DVD CXONE-AL50D-V4 The CX-One is a comprehensive software package that integrates 1 license Support Software for OMRON PLCs and components. CX-One runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista 3 licenses (32-bit/64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version) / Windows 10 licenses 10 (32-bit/64-bit version) CX-One Version 4.@ includes CX-Programmer and CX-Simulator. For details, refer to the CX-One catalog (Cat. No. R134). Model Media Note 1: Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details. 2: Before ordering the software on a DVD, be sure that your computer and drive are compatible with the DVD format. * The CXONE-AL00D-V4 contains only the DVD installation media for users who have purchased the CX-One Version 4. @ and does not include the license number. Enter the license number of the CX-One Version 4. @ when installing. (The license number of the CX-One Version 3. @ or lower cannot be used for installation.) ● Support Software in CX-One Ver.4.@ The following tables lists the Support Software that can be installed from CX-One. Support Software in CX-One Outline CX-Programmer Application software to create and debug programs for CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series CPU Units, and to create and monitor data for CS/CJ-series Position Control Units. CX-Integrator Application software to build and set up FA networks, such as Controller Link, DeviceNet, CompoNet, CompoWay/F, and Ethernet networks. The Routing Table Component and Data Link Component can be started from here. DeviceNet Configuration functionality is also included. Switch Box Utility Utility software that helps you to debug PLCs. It helps you to monitor the I/O status and to monitor/change present values within the PLC you specify. CX-Protocol Application software to create protocols (communications sequences) between CS/CJ/CP/NSJ-series or C200HX/HG/HE Serial Communications Boards/Units and general-purpose external devices. CX-Simulator Application software to simulate CS/CJ/CP/NSJ-series CPU Unit operation on the computer to debug PLC programs without a CPU Unit. CX-Position Application software to create and monitor data for CS/CJ-series Position Control Units. (except for High-speed type) CX-Motion-NCF Application software to creat and monitor data for CS/CJ-series Position Control Units with MECHATROLINK-II * interface (NC@71). CX-Motion-MCH Application software to create data, and monitor program, and monitor data for CS/CJ-series Motion Control Units with MECHATROLINK-II * interface (MCH71). CX-Motion Application software to create data for CS/CJ-series, C200HX/HG/HE, and CVM1/CV-series Motion Control Units, and to create and monitor motion control programs. CX-Drive Application software to set and control data for Inverters and Servos. CX-Process Tool Application software to create and debug function block programs for CS/CJ-series Loop Controllers (Loop Control Units/Boards, Process Control CPU Units, and Loop Control CPU Units). Faceplate Auto-Builder for NS Application software that automatically outputs screen data as project files for NS-series PTs from tag information in function block programs created with the CX-Process Tool. CX-Designer Application software to create screen data for NS-series PTs. NV-Designer Applications software to create screen data for NV-series small PTs. CX-Configurator FDT Applications software to setting various units by installing its DTM module. CX-Thermo Application software to set and control parameters in components such as Temperature Control Units. CX-FLnet Application software for system setting and monitoring of CS/CJ-series FL-net Units. Network Configurator Application software for setting the tag datalink at the built-in EtherNet/IP port. CX-Server Middleware necessary for CX-One applications to communicate with OMRON components, such, such as PLCs, Display Devices, and Temperature Control Units. Communications Middleware Middleware necessary to communicate with CP1L CPU Units with built-in Ethernet port. PLC Tools (Installed automatically.) A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following: I/O tables, PLC memory, PLC Setup, Data Tracing/Time Chart Monitoring, PLC Error Logs, File Memory, PLC clock, Routing Tables, and Data Link Tables. Note: If the complete CX-One package is installed, approximately 4.0 GB of Hard disk space will be required. 22 Programmable Controllers CS1G/H ■ Connecting Cables for CX-One Components (e.g. CX-Programmer) Specifications Product name Applicable computers Cable length Connection configuration IBM PC/AT or compatible computer + CS1W-CN226/626 + Peripheral port of CPU Unit Can be used for both peripheral bus and host link. RS-232C Cables between Programming Device (computer) and peripheral port Peripheral Port Connecting Cable CS1W-CN226/626 Computer (9-pin RS-232C) IBM PC/AT or compatible computer (D-Sub 9-pin) The following configuration can be used when using an RS-232C cable to connect to an IBM PC/AT or compatible computer. IBM PC/AT or compatible computer + XW2Z-200S-CV/V or XW2Z-500S-CV/V + Peripheral port of CPU Unit. RS-232C Cable XW2Z-200S-CV/V XW2Z-500S-CV/V 0.1 m 2m Serial Communications Board's RS-232C ports Computer (9-pin RS-232C) 5m RS-232C Cable XW2Z-200S-CV/V (2 m) XW2Z-500S-CV/V (5 m) Active CPU Unit Standby CPU Unit RUN ERR/ALM DPL01 L INH BKUP PRPHL COMM SYSMAC CS1D-CPU67H R ERR/ALM INH BKUP PRPHL COMM LEFT CPU SYSMAC CS1D-CPU67H USE PROGRAMMABLE CONTROLLER NO USE USE BUSY MCPWR BUSY NO USE OPEN DPL SW ON OFF SPL DPL ACT. ACT. LEFT RIGHT ON PERIPHERAL INIT. +5V SW PRPHL COMM A39512 RSV ON PORT PORT DUPLEX RS-422A/485 XW2Z-500S-CV Can be used for host link only. Cannot be used for peripheral bus. RIGHT CPU MCPWR OPEN NT-AL001 XW2Z-200S-CV RS-422A/485 XW2Z-200S-V 2m RUN DPL STATUS ACTIVE CPU STATUS ACTIVE CPU STATUS PROGRAMMABLE CONTROLLER PERIPHERAL RS-232C Can be used for both peripheral bus and host link, and is equipped with an anti-static connector. CPU Unit's built-in RS-232C port Note: We recommend the following configuration if the CX-Programmer is always connected and you want to avoid switching to the other CPU Unit when an error occurs. Terminator ON +5 V must be supplied to the NT-AL001 at computer side. Use when connecting to the peripheral port CS1W-CN118 with a XW2Z200S-CV/V or XW2Z-500S-CV/V RS-232C Cable. CS1W-CN118 IBM PC/AT or compatible computer + XW2Z-200S-CV/V or XW2Z-500S-CV/V + RS-232C port of CPU Unit or Serial Communications Board/Unit IBM PC/AT or compatible computer (D-Sub 9-pin) CS1W-CN626 6m Peripheral port Connecting Cables between Programming Device (computer) and RS-232C port CS1W-CN226 2m Peripheral port Model Remarks RS-422A Adapter CJ1W-CIF11 or NT-AL001 XW2Z-500S-V 5m CX-Programmer IBM PC/AT or compatible computer + CS1W-CIF31 + CS1W-CN226/626 + Peripheral port of CPU Unit USB-Serial Conversion Cable CS1W-CIF31 Computer USB port USB-Serial Conversion Cable (PC driver CD-ROM IBM PC/AT or included) compatible computer (D-Sub 9-pin) Conforms to USB 2.0 Specifications. Serial Connecting Cable CS1W-CN226/626 XW2Z-200S-CV/500S-CV XW2Z-200S-V/500S-V CQM1-CIF02 Peripheral port or RS-232C port IBM PC/AT or compatible computer + CS1W-CIF31 + XW2Z-200S-CV/500S-CV + CS1W-CN118 + Peripheral port of CPU Unit IBM PC/AT or compatible computer + CS1W-CIF31 + XW2Z-200S-V/500S-V + CS1W-CN118 + Peripheral port of CPU Unit IBM PC/AT or compatible computer + CS1W-CIF31 + XW2Z-200S-CV/500S-CV + CS1W-CN118 + RS-232C port of CPU Unit or Serial Communications Board/Unit IBM PC/AT or compatible computer + CS1W-CIF31 + XW2Z-200S-V/500S-V + RS-232C port of CPU Unit or Serial Communications Board/ Unit The USB Serial Conversion Cable connects to the serial connecting cable, 0.5 m which connects to the PLC’s peripheral port or RS-232C port. Can be used for both peripheral bus and host link. Can be used for both peripheral bus and host link. CS1W-CIF31 Can be used for host link only. Cannot be used for peripheral bus. Can be used for both peripheral bus and host link. Can be used for host link only. Cannot be used for peripheral bus. Programmable Controllers CS1G/H 23 Note: Either of the serial communications modes listed in the following table can be used to connect CX-One Support Software (e.g., the CX-Programmer) to a CS1-series PLC. Serial communications mode Features Peripheral bus This mode can provide high-speed communications, so this mode is normally used to connect when using CX-One component software such as the CX-Programmer. • Supports 1:1 connections only. • The Programming Device’s baud rate Host Link (SYSWAY) This is a general host computer communications protocol, which supports 1:1 and 1:N connections. • Host link operates at a slower speed than peripheral bus. • Host link supports 1:N connections as well as long-distance connections when RS-422A/RS-485 is used for a connection through a modem or optical adapter. ■ Programming Console Product name Programming Console Programming Console Key Sheet Programming Console Connecting Cable Cable model (Separate item) Specifications Can be connected to the CPU Unit’s peripheral port only. Cannot be connected to CS1W-CN224: 2 m the RS-232C port. CS1W-CN624: 6 m A CS1W-KS001-E Programming Console Key Sheet is required (sold separately). Connection configuration Model CS1W-CN224 (2 m) CS1W-CN624 (6 m) Peripheral port C200H-PRO27-E Programming Console Key Sheet CS1W-KS001 Programming Console C200H-PRO27 For the following Programming Consoles: C200H-PRO27 CS1W-KS001-E For C200H-PRO27 connection, Cable length: 2 m CS1W-CN224 For C200H-PRO27 connection, Cable length: 6 m CS1W-CN624 ■ Connecting Cables for NS-series PTs Specifications Product name Connection configuration Cable length Model Connecting Cables between an NS-series PT and the RS-232C port of CPU Unit or Serial Communications Board/Unit Connecting Cables for NS-series PTs Serial Communications Board's NS-series PT XW2Z-200T 5m XW2Z-500T 2m XW2Z-200T-2 5m XW2Z-500T-2 RS-232C RS-232C Cable XW2Z-200T (2 m) XW2Z-500T (5 m) CPU Unit's built-in RS-232C port Connecting Cables between an NS-series PT and the peripheral port of CPU Unit 24 2m Programmable Controllers CS1G/H Accessories and Maintenance Parts Product name Memory Cards Specifications HMC-EF183 Memory Card Adapter (Adapts to a computer’s PCMCIA card slot.) HMC-AP001 Product name Battery Set I/O Terminal Cover Model Flash Memory, 128 MB Specifications Model Battery for CS-series maintenance Note 1: A battery is included with the CPU Unit as standard equipment. 2: The battery life is 5 years at an ambient temperature of 25°C, although the lifetime can be as short as 1.1 years under adverse temperature and power conditions. 3: Use a replacement battery that was manufactured within the last two years. CS1W-BAT01 Cover for 10-pin Terminal Blocks C200H-COV11 Protective cover for unused Power Supply Unit connector in C200H Backplane C500-COV01 Protective cover for unused CS-series Unit connector in Backplane CV500-COV01 For unused I/O slot spaces in the CS1W-BC@@3/BI@@3 or C200HW-BI@@@ Backplanes C200H-SP001 For unused I/O slot spaces in the CS1W-BC@@2/BI@@2 or CS1W-BC@@3/BI@@3 Backplanes CS1W-SP001 Connector Cover Space Units Backplane Insulation Plate (for C200HX/HG/HE Expansion I/O Backplane) Used to electrically insulate the Backplane from the control panel as a noise countermeasure. 10 slots C200HW-ATTA2 8 slots C200HW-ATT82 5 slots C200HW-ATT52 3 slots C200HW-ATT32 Contact relays 24 VDC For Relay Output Unit C200H-OC221/222/223/224/225 G6B-1174P-FD-US-M DC24 Programming Console Mounting Bracket Use to mount a C200H-PRO27 Programming Console in a control panel. C200H-ATT01 Terminator Connected to last Long-distance Expansion Rack (for CS1W-IC102). Two are included with the CS1W-IC102 I/O Control Unit. CV500-TER01 RS-422A Converter Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 RS-232C/RS-422A Link Adapter RS-232C × 1 port RS-422A terminal block NT-AL001 DIN Track Mounting Accessories Product name Specifications Model DIN Track Mounting Bracket 1 set (package of 2 brackets) C200H-DIN01 Track length: 50 cm Height: 7.3 mm PFP-50N DIN Track Track length: 1 m Height: 7.3 mm PFP-100N Track length: 1 m Height: 16 mm PFP-100N2 End Plate PFP-M Note: Order in lots of 10. Spacer PFP-S Programmable Controllers CS1G/H 25 Basic I/O Units CS1 Basic I/O Units ■ Input Units Words required Mountable Racks Unit type Product name CPU Rack Specifications CS1W-BC C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 LongRack distance CS1W-BI Expansion Rack @@3 @@2 SYSMAC BUS Slave Rack (I/O bits: CIO 0000 to CIO 0319) Current consumption (A) Model 5V 26 V system system @@3 @@2 24 VDC, 7 mA, 16 inputs Yes Yes No Yes Yes Yes No 1 word 0.10 --- CS1W-ID211 24 VDC, 6 mA, 32 inputs Yes Yes No Yes Yes Yes No 2 words 0.15 --- CS1W-ID231 24 VDC, 7 mA, 64 inputs Yes Yes No Yes Yes Yes No 4 words 0.15 --- CS1W-ID261 24 VDC, approx. 5 mA, 96 inputs Yes Yes No Yes Yes Yes No 6 words 0.20 --- CS1W-ID291 100 to 120 VAC, AC Input Unit 16 inputs 100 to 120 VDC, 16 inputs Yes Yes No Yes Yes Yes No 1 word 0.11 --- CS1W-IA111 200 to 240 VAC, 16 inputs Yes Yes No Yes Yes Yes No 1 word 0.11 --- CS1W-IA211 DC Input Unit CS1 Basic I/O Units ■ Output Units Mountable Racks CPU Rack Unit type Product name Specifications CS1W-BC CS1 Expansion CS1 LongRack distance CS1W-BI Expansion Rack @@3 @@2 SYSMAC BUS Slave Rack Words required Current consumption (A) Model 5V system 26 V system CS1W-OC201 @@3 @@2 250 VAC or 120 VDC, Relay Output 2 A max. Units Independent contacts, 8 outputs Yes Yes No Yes Yes Yes No 1 word 0.10 250 VAC or 120 VDC, 2 A max. 16 outputs Yes Yes No Yes Yes Yes No 1 word 0.13 0.006 per simultaneously ON outputs 12 to 24 VDC, 0.5 A 16 outputs Sinking Yes Yes No Yes Yes Yes No 1 word 0.17 --- CS1W-OD211 24 VDC, 0.5 A 16 outputs Sourcing Yes Yes No Yes Yes Yes No 1 word 0.17 --- CS1W-OD212 12 to 24 VDC, 0.5 A 32 outputs Sinking Yes Yes No Yes Yes Yes No 2 words 0.27 --- CS1W-OD231 24 VDC, 0.5 A 32 outputs Sourcing Yes Yes No Yes Yes Yes No 2 words 0.27 --- CS1W-OD232 12 to 24 VDC, 0.3 A 64 outputs Sinking Yes Yes No Yes Yes Yes No 4 words 0.39 --- CS1W-OD261 24 VDC, 0.3 A 64 outputs Sourcing Yes Yes No Yes Yes Yes No 4 words 0.39 --- CS1W-OD262 12 to 24 VDC, 0.1 A 96 outputs Sinking Yes Yes No Yes Yes Yes No 6 words 0.48 --- CS1W-OD291 12 to 24 VDC, 0.1 A 96 outputs Sourcing Yes Yes No Yes Yes Yes No 6 words 0.48 --- CS1W-OD292 1 word 0.23 max. (0.07 + 0.02 × number of ON points) --- CS1W-OA201 1 word 0.406 max. (0.07 + 0.021 × number of ON points) --- CS1W-OA211 Transistor Output Units CS1 Basic I/O Units Triac Output Units 250 VAC, 2 A max. 8 outputs 250 VAC, 0.5 A max. 16 outputs 26 C200HX/ HG/HE Expansion I/O Rack Yes Yes Programmable Controllers Yes Yes No No CS1G/H Yes Yes Yes Yes Yes Yes No No CS1W-OC211 ■ I/O Units Mountable Racks Product name Unit type CPU Rack Specifications CS1W-BC @@3 @@2 C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 SYSMAC BUS Slave Rack Words required Current consumption (A) 5V system Model 26 V system 24 VDC, 6 mA 32 inputs DC Input/ Transistor Output Unit CS1W-MD261 12 to 24 VDC, 0.3 A 32 outputs Sourcing Yes Yes No Yes Yes Yes No 24 VDC, 6 mA 32 inputs 2 input words and 2 output words 0.27 --- CS1W-MD262 24 VDC, 0.3 A 32 outputs Sourcing 24 VDC, approx. 5 mA 48 inputs CS1 Basic I/O Units CS1W-MD291 12 to 24 VDC, 0.1 A 48 outputs Sinking Yes Yes No Yes Yes Yes No 24 VDC, approx. 5 mA 48 inputs 3 input words and 3 output words 0.35 --- CS1W-MD292 12 to 24 VDC, 0.1 A 48 outputs Sourcing TTL I/O Unit 5 VDC 32 inputs, 32 outputs Yes Yes No Yes Yes Yes No 2 input words and 2 output words 0.27 --- CS1W-MD561 Note: The C200H-ID001 (8 no-voltage contact inputs, NPN) and C200H-ID002 (8 no-voltage contact inputs, PNP) cannot be used. ● Applicable Connectors Connector for CS1 Basic I/O Units (32 inputs, 64 inputs, 32 outputs, 64 outputs, 32 inputs/32 outputs) Name Applicable Connectors Connection Applicable Units Model Soldered FCN-361J040-AU Connector FCN-360C040-J2 Connector cover C500-CE404 (Included with Unit) Crimped FCN-363J040 Housing FCN-363J-AU Contact FCN-360C040-J2 Connector cover C500-CE405 Pressure welded FCN-367J040-AU/F C500-CE403 Connector for CS1 Basic I/O Units (96 inputs, 96 outputs, 48 inputs/48 outputs) Name Applicable Connectors Connection Applicable Units Model Soldered FCN-361J056-AU Connector FCN-360C056-J3 Connector cover CS1W-CE561 (Included with Unit) Crimped FCN-363J056 Housing FCN-363J-AU Contact FCN-360C056-J3 Connector cover CS1W-CE562 Pressure welded FCN-367J056-AU CS1W-CE563 Programmable Controllers CS1G/H 27 ■ Interrupt Input Unit Specifications Unit type Product name Mountable Racks CS1 Expansion CPU Rack Input pulse C200HX/ CS1 LongRack External width I/O Input Input HG/HE distance connecCS1W-BC Expansion CS1W-BI Expansion points voltage current tion I/O Rack Rack ON OFF @@3 @@2 @@3 @@2 time time SYSMAC Words BUS required Slave Rack Current consumption (A) Model 5V 26 V system system Interrupt Input Unit CS1 Basic I/O Units 16 inputs 24 VDC 7 mA Remov0.1 0.5 able ms ms terminal max. max. block Yes Yes * * Yes Yes No * Yes No 1 word 0.10 --- CS1W-INT01 * Interrupt inputs are not supported on these Racks (i.e., used as normal I/O Unit). ■ Quick-response Input Unit Specifications Unit type Product name Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongInput pulse External I/O Input Input HG/HE Rack distance width connecpoints voltage current Expansion Expansion CS1W-BC CS1W-BI (ON time) tion I/O Rack Rack @@3 @@2 @@3 @@2 Quickresponse Input Unit 16 inputs CS1 Basic I/O Units 24 VDC 7 mA Removable terminal block 0.1 ms max. Yes Yes No Yes Yes SYSMAC Words BUS required Slave Rack Yes No 1 word Current consumption (A) Model 5V 26 V system system 0.10 --- CS1W-IDP01 ■ B7A Interface Unit Mountable Racks Unit type Product name Specifications CS1W-BC B7A Interface Unit CS1 Basic I/O Unit CPU Rack C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 LongRack distance CS1W-BI Expansion Rack @@3 @@2 SYSMAC BUS Slave Rack Words required Current consumption (A) 5V system 26 V system Model @@3 @@2 32 inputs Yes Yes No Yes Yes Yes No 2 words 0.09 --- CS1W-B7A12 32 outputs Yes Yes No Yes Yes Yes No 2 words 0.09 --- CS1W-B7A02 0.09 --- CS1W-B7A21 0.09 --- CS1W-B7A22 16 inputs/outputs Yes Yes No Yes Yes Yes No 1 input word and 1 output word 32 inputs/outputs Yes Yes No Yes Yes Yes No 2 input words and 2 output words ■ Safety Relay Unit Specifications Unit type Product name Contact Number CPU Rack Power Number External type of Function supply of input connec(Safety general voltage words tions CS1W-BC output) inputs @@3 @@2 Safety Relay Unit CS1Basic I/O Units 28 Mountable Racks Emergency stop Unit 24 VDC 1 word 4 or 2 DPST- inputs/ words NO com(Shared mon inputs) Programmable Controllers Removable terminal block Yes CS1G/H Yes C200HX/ HG/HE Expansion I/O Rack No CS1 Expansion CS1 Longdistance Rack Expansio CS1W-BI n Rack @@3 @@2 Yes Yes Yes SYSMAC Words BUS required Slave Rack No 1 word Current consumption (A) Model 5V 26 V system system 0.10 --- CS1W-SF200 C200H Basic I/O Units and C200H Group-2 High-density I/O Units ■ Input Units Words required Mountable Racks Unit type Product name Specifications CPU Rack CS1W-BC DC Input Unit AC Input Unit C200H Basic I/O Units DC Input Unit CS1 Expansion CS1 LongRack distance CS1W-BI Expansion Rack @@3 @@2 SYSMAC BUS Slave Rack (I/O bits: CIO 0000 to CIO 0319) Model 5V 26 V system system @@3 @@2 12 to 24 VDC, 8 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-ID211 24 VDC, 16 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-ID212 100 to 120 VAC, 8 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IA121 100 to 120 VAC, 16 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IA122 200 to 240 VAC, 8 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IA221 200 to 240 VAC, 16 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IA222 Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IM211 24 VAC/VDC, 16 inputs Yes No Yes Yes No No Yes 1 word 0.01 --- C200H-IM212 24 VDC, 32 inputs Yes No Yes Yes No No No 2 words 0.10 --- C200H-ID216 24 VDC, 64 inputs Yes No Yes Yes No No No 4 words 0.12 --- C200H-ID217 24 VDC, 32 inputs, 6 mA Yes No Yes Yes No No No 2 words 0.10 --- C200H-ID218 24 VDC, 64 inputs, 6 mA Yes No Yes Yes No No No 4 words 0.12 --- C200H-ID219 AC/DC Input Unit 12 to 24 VAC/VDC, 8 inputs C200H Group-2 Highdensity I/O Units C200HX/ HG/HE Expansion I/O Rack Current consumption (A) Programmable Controllers CS1G/H 29 ■ Output Units Mountable Racks Unit type Product name CPU Rack Specifications CS1W-BC Relay Contact Output Unit C200H Basic I/O Units Transistor Output Unit Triac Output Unit C200H Group-2 Highdensity I/O Units 30 Transistor Output Units C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 SYSMAC BUS Slave Rack Words required Yes 1 word Current consumption (A) Model 5V system 26 V system @@3 @@2 250 VAC or 24 VDC, 2 A max. 8 outputs Yes No 250 VAC or 24 VDC, 2 A max. 12 outputs Yes No Yes Yes No No Yes 1 word 0.01 250 VAC or 24 VDC, 2 A max. 16 outputs Yes No Yes Yes No No Yes 1 word 0.05 0.075 per 8 simultaneously ON outputs C200H-OC225 250 VAC or 24 VDC, 2 A max. Independent contacts: 5 outputs Yes No Yes Yes No No Yes 1 word 0.01 0.075 per 8 simultaneously ON outputs C200H-OC223 250 VAC or 24 VDC, 2 A max. Independent contacts: 8 outputs Yes No Yes Yes No No Yes 1 word 0.01 0.075 per 8 simultaneously ON outputs C200H-OC224 12 to 48 VDC, 1 A 8 outputs Sinking Yes No Yes Yes No No Yes 1 word 0.14 --- C200H-OD411 24 VDC, 2.1 A 8 outputs Sinking Yes No Yes Yes No No Yes 1 word 0.14 --- C200H-OD213 5 to 24 VDC, 0.3 A 8 outputs Sourcing Yes No Yes Yes No No Yes 1 word 0.01 24 VDC, 0.3 A 12 outputs Sinking Yes No Yes Yes No No Yes 1 word 0.16 5 to 24 VDC, 0.3 A 12 outputs Sourcing Yes No Yes Yes No No Yes 1 word 0.01 24 VDC, 0.3 A 16 outputs Sinking Yes No Yes Yes No No Yes 1 word 0.18 --- C200H-OD212 250 VAC, 1.2 A max. 8 outputs Yes No Yes Yes No No Yes 1 word 0.18 --- C200H-OA223 250 VAC, 0.5 A max. 12 outputs Yes No Yes Yes No No Yes 1 word 0.27 --- C200H-OA224 4.5 to 26.4 V, 16 to 100 mA 32 outputs Sinking Yes No Yes Yes No No No 2 words 0.27 --- C200H-OD218 4.5 to 26.4 V, 16 to 100 mA 64 outputs Sinking Yes No Yes Yes No No No 4 words 0.48 --- C200H-OD219 Yes Yes No No 0.01 C200H-OC221 0.075 per 8 simultaneously ON outputs Programmable Controllers CS1G/H C200H-OC222 0.075 per 8 simultaneously ON outputs --0.075 per 8 simultaneously ON outputs C200H-OD216 C200H-OD211 C200H-OD217 ■ Analog Timer Unit Mountable Racks Unit type Product name Specifications CPU Rack CS1W-BC @@3 @@2 Yes No C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 LongRack distance CS1W-BI Expansion Rack @@3 @@2 SYSMAC BUS Slave Rack Words required Yes 1 word Current consumption (A) Model 5V 26 V system system Analog Timer Unit C200H Basic I/O Units 4-point timer Yes Yes No No 0.06 Programmable Controllers --- C200H-TM001 CS1G/H 31 Special I/O Units, CPU Bus Units, and Inner Boards CS1 Special I/O Units, CPU Bus Units, and Inner Boards ■ Temperature Sensor Input Units (Process I/O Units) Specifications Unit type Product name I/O points Signal range selection Signal range B, E, J, K, L, N, R, S, 4 4 T, U, indepeninputs WRe5-26, Isolated-type dent PL II, Thermocou±100 mV ple Input Units CS1 Special I/O Units CS1 CS1 CPU Rack C200HX/ Expansion LongHG/HE ConverRack disExternal Expansion tance connection CS1W-BC CS1W-BI sion I/O speed ExpanRack sion @@3 @@2 @@3 @@2 Rack No. of SYSMAC unit BUS numbers Slave allocated Rack Current consumption (A) Model 5V 26 V system system 20 ms/ 4 inputs, 10 ms/ 2 inputs Yes Yes No Yes Yes Yes No 0.12 0.08 CS1W-PTS11 250 ms/ 4 inputs Yes Yes No Yes Yes Yes No 0.25 --- CS1W-PTS51 8 8 R, S, K, J, 250 ms/ indepeninputs T, L, B 8 inputs dent Yes Yes No Yes Yes Yes No 0.18 0.06 CS1W-PTS55 4 B, E, J, K, 4 150 ms/ indepen- N, R, S, T, inputs 4 inputs dent ±80mV Yes Yes No Yes Yes Yes No 0.15 0.15 CS1W-PTS01-V1 Removable 20 ms/ terminal 4 inputs, Yes block 10 ms/ 2 inputs Yes No Yes Yes Yes No 0.12 0.07 CS1W-PTS12 4 4 R, S, K, J, indepeninputs T, L, B dent Pt100 Ω 4 (JIS, IEC), 4 indepenJPt100 Ω, Isolated-type inputs dent Pt50 Ω, Resistance Ni508.4 Ω Thermome- 1 unit number’s words 4 Pt100 Ω 4 250 ms/ indepen- (JIS, IEC), inputs 4 inputs dent JPt100 Ω Yes Yes No Yes Yes Yes No 0.25 --- CS1W-PTS52 8 Pt100 Ω 8 250 ms/ indepen- (JIS, IEC), inputs 8 inputs dent JPt100 Ω Yes Yes No Yes Yes Yes No 0.18 0.06 CS1W-PTS56 4 Pt100 Ω 4 100 ms/ indepen- (JIS, IEC), inputs 4 inputs dent JPt100 Ω Yes Yes No Yes Yes Yes No 0.15 0.15 CS1W-PTS02 Isolated-type Resistance 4 4 100 ms/ Thermomeindepen- Ni508.4 Ω inputs 4 inputs ter Input Unit dent (Ni508.4 W) Yes Yes No Yes Yes Yes No 0.15 0.15 CS1W-PTS03 ter Input Units 32 Mountable Racks Programmable Controllers CS1G/H ■ Analog Input Units ● Analog Input Units Specifications Unit type Product name Analog Input Units Signal I/O range points selection Signal range 1 to 5 V, 0 to 5 V, 4 4 0 to 10 V, inde-10 to inputs pendent 10 V, 4 to 20 mA 8 1 to 5 V, 8 inde0 to 5 V, inputs pendent 0 to 10 V, -10 to 10 V, 4 to 16 16 20 mA indeinputs pendent CS1 Special I/O Units ConnectorTerminal Block Conversion Unit for CS1WAD161 Mountable Racks CS1 CS1 C200HX/ CPU Rack Expansion LongHG/HE Conver- External ResoluRack distance Expansion connection CS1W-BC sion I/O CS1W-BI Expanspeed tion sion @@3 @@2 Rack @@3 @@2 Rack 1/8,000 (Can also be set to 1/4,000.) 250 µs/ input (Can also be set to 1 ms/ input.) 1/8,000 (Can also be set to 1/4,000.) 250 µs/ input (Can also be set to 1 ms/ input.) No. of SYSMAC unit BUS numbers Slave allocated Rack Removable terminal block Yes Removable terminal block Yes Yes No Yes Yes Yes No MIL connector Yes Yes No Yes Yes Yes No Yes No Yes Yes Yes No Current consumption (A) Model 5V 26 V system system 0.12 0.09 CS1W-AD041-V1 0.12 0.09 CS1W-AD081-V1 0.15 0.06 CS1W-AD161 1 unit number’s words 2 unit numbers’ words Slim terminal block Terminal: 34, dimension: 128 x 40 x 39 mm XW2D-34G6 Connection cable Cable length: 2 m XW2Z-200C --- ● Isolated-type DC Input Units (Process I/O Units) Specifications Unit type Product name Mountable Racks CS1 C200HX/ Expansion CS1 LongHG/HE Rack Conversion External distance Expanspeed connection Expansion CS1W-BC sion I/O CS1W-BI Rack Rack @@3 @@2 @@3 @@2 CPU Rack I/O points Signal range Current consumption No. of SYSMAC unit (A) BUS numbers Slave allocated 5V 26 V Rack system system Model 4 to 20 mA, 0 to 20 mA, 0 to 10 V, ±10 V, 4 0 to 5 V, inputs ±5 V, 1 to 5 V, 0 to 1.25 V, ±1.25 V 20 ms/ 4 inputs, 10 ms/ 2 inputs Yes Yes No Yes Yes Yes No 0.12 0.12 CS1W-PDC11 4 to 20 mA, 8 0 to 10 V, inputs 0 to 5 V, 1 to 5 V, 250 ms/ 8 inputs Yes Yes No Yes Yes Yes No 0.18 0.06 CS1W-PDC55 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 4 0 to 5 V, inputs ±5 V, 0 to 10 V, ±10 V 100 ms/ 4 inputs Yes Yes No Yes Yes Yes No 0.15 0.16 CS1W-PDC01 4 4 to 20 mA, inputs 1 to 5 V 100 ms/ 4 inputs Yes Yes No Yes Yes Yes No 0.15 0.16 CS1W-PTW01 Power Transducer Input Unit 8 0 to 1 mA, inputs ±1 mA 200 ms/ 8 inputs Yes Yes No Yes Yes Yes No 0.15 0.08 CS1W-PTR01 DC Analog Input Unit (100 mV) 8 0 to 100 mV, 200 ms/ inputs ±100 mV 8 inputs Yes Yes No Yes Yes Yes No 0.15 0.08 CS1W-PTR02 Isolatedtype DC Input Units CS1 Special I/O Units Removable terminal block 1 unit number’s words Isolatedtype 2-Wire Transmitter Input Unit Programmable Controllers CS1G/H 33 ■ Analog Output Units ● Analog Output Units Specifications Unit type Product name Analog Output Units CS1 Special I/O Units I/O points Signal range selection Signal range Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongConver- External Rack HG/HE distance Resosion connecExpansion Expansion lution speed tion CS1W-BC CS1W-BI I/O Rack Rack @@3 @@2 @@3 @@2 1 to 5 V, 0 to 5 V, 4 1 ms/ 4 0 to 10 V, 1/4000 indeoutput outputs pendent -10 to 10 V, 4 to 20 mA 1 to 5 V, 8 8 1 ms/ 0 to 5 V, inde1/4000 outputs output 0 to 10 V, pendent -10 to 10 V Removable terminal block 8 8 1 ms/ inde4 to 20 mA 1/4000 outputs output pendent No. of SYSMAC unit BUS numbers Slave allocated Rack Yes Yes No Yes Yes Yes No Yes Yes No Yes Yes Yes No Yes Yes No Yes Yes Yes No 1 unit number’s words Current consumption (A) Model 5V 26 V system system 0.13 0.18 CS1W-DA041 0.13 0.18 CS1W-DA08V 0.13 0.25 CS1W-DA08C ● Isolated-type Control Output Units (Process I/O Units) Mountable Racks Specifications Unit type Product name I/O points Signal range selection Signal range Conver- External sion connecspeed tion CPU Rack C200HX/ HG/HE Expansion I/O Rack CS1W-BC @@3 @@2 CS1 Special I/O Units Isolatedtype Control Output Units 4 4 to 4 inde20 mA, outputs pendent 1 to 5V 0 to 10V, ±10V, 4 4 0 to 5V, indeoutputs ±5V, pendent 0 to 1V, ±1V 100 ms/ outputs 40 ms/ outputs Yes Removable terminal block Yes No CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 Yes Yes Yes No. of SYSMAC unit BUS numbers Slave allocated Rack No Current consumption (A) Model 5V 26 V system system 0.15 0.16 CS1W-PMV01 0.12 0.12 CS1W-PMV02 1 unit number’s words Yes Yes No Yes Yes Yes No ■ Analog I/O Units Specifications Unit type Product name Analog I/O Units CS1 Special I/O Units 34 Signal I/O range points selection 4 inde4 inputs pendent 4 inde4 outputs pendent Signal range Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongConver- External Rack ResoluHG/HE distance sion connection Expansion Expansion CS1W-BC CS1W-BI speed tion I/O Rack Rack @@3 @@2 @@3 @@2 1 to 5V, 0 to 5V, 0 to 10V, -10 to 10V, 4 to 20 mA 1/4000 1 to 5V, 0 to 5V, 0 to 10V, -10 to 10V 1/4000 1 ms/ output 1 ms/ output Programmable Controllers Removable terminal block Yes CS1G/H Yes No Yes Yes Yes No. of SYSMAC unit BUS numbers Slave allocated Rack No 1 unit number’s words Current consumption (A) Model 5V 26 V system system 0.20 0.20 CS1W-MAD44 ■ Isolated-type Pulse Input Units (Process I/O Units) Mountable Racks CPU Rack Unit type Product name C200HX/ HG/HE Expansion I/O Rack Specifications CS1W-BC @@3 @@2 Yes Yes CS1 Expansion Rack CS1W-BI @@3 @@2 Yes Yes CS1 Longdistance Expansion Rack SYSMAC BUS Slave Rack Yes No Current consumption (A) No. of unit numbers allocated Model 5V 26 V system system Isolated-type Pulse Input Unit CS1 Special I/O Units 4 pulse inputs No 1 unit number’s words 0.20 0.16 CS1W-PPS01 ■ Loop Control Board/Loop Control Unit Mountable Racks Unit type Product name Specifications Loop Control Board CS1 Inner Board 50 blocks max. (total control blocks and operation blocks) *1 *1 Yes Yes RDY EXEC COMM CS1 Expansion CS1 Longdistance Rack Expansion CS1W-BI Rack @@3 @@2 No No SYSMAC BUS Slave Rack No No Current consumption (A) No. of unit numbers allocated Model 5V 26 V system system *2 0.22 --- CS1W-LCB01 *2 0.22 --- CS1W-LCB05 --- 500 blocks max. (total control blocks and operation blocks) PORT LCB01 *1. *2. CPU Rack C200HX/ HG/HE Expansion CS1W-BC I/O Rack @@3 @@2 Mount a CS1W-LCB01/05 Loop Control Board in a CS1G/H-CPU@@H CPU Unit or a CS1D-CPU@@S CS1D Duplex System CPU Unit. NT-AL001 Link Adapters consume an additional 0.15 A each when used. ■ High-speed Counter Units Specifications Unit type Product name High-speed Counter Units Number Encoder A and B of count inputs, and Z pulse channels input signal 2 CS1 Special I/O Units Input voltage: 5 VDC, 12 VDC, or 24 VDC (only 1 axis for 5 V or 12 V input) RS-422 line driver 4 Input voltage: 5 VDC, 12 VDC, or 24 VDC (up to 2 axes for 5 V or 12 V input) RS-422 line driver Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongMaximum Rack HG/HE distance count Expansion Expansion speed CS1W-BC CS1W-BI I/O Rack Rack @@3 @@2 @@3 @@2 No. of SYSMAC unit BUS numbers Slave allocated Rack Current consumption (A) Model 5V 26 V system system 50 kHz Yes Yes No Yes Yes Yes No 0.36 --- CS1W-CT021 0.45 --- CS1W-CT041 4 unit numbers’ words 500 kHz 50 kHz Yes Yes No Yes Yes Yes No 500 kHz Programmable Controllers CS1G/H 35 ■ Customizable Counter Units Mountable Racks Unit type Product name Customizable Counter Units CS1 Special I/O Units CPU Rack C200HX/ HG/HE Expansion CS1W-BC I/O Rack @@3 @@2 Specifications CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 SYSMAC BUS Slave Rack Two-axis pulse input Two-axis pulse output 12 DC inputs 8 transistor outputs Yes Yes No Yes Yes Yes No Single-axis pulse input 1 analog input 2 analog outputs 12 DC inputs 8 transistor outputs Yes Yes No Yes Yes Yes No Two-axis pulse input 2 analog outputs 12 DC inputs 8 transistor outputs Yes Yes No Yes Yes Yes 12 DC inputs 8 transistor outputs Yes Yes No Yes Yes Yes No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system 0.80 --- CS1W-HCP22-V1 0.75 0.15 CS1W-HCA12-V1 No 0.75 0.15 CS1W-HCA22-V1 No 0.60 --- CS1W-HIO01-V1 1 unit number’s words ■ Position Control Units Mountable Racks Specifications Unit type Product name Control output interface Pulse-train, Position Control open-collector outputs Units Pulse-train, linedriver outputs CPU Rack C200HX/ HG/HE Expansion CS1W-BC Number I/O Rack of axes @@3 @@2 SYSMAC BUS Slave Rack 1 axis Yes Yes No Yes Yes Yes No 2 axes Yes Yes No Yes Yes Yes No 4 axes Yes Yes No 1 axis Yes Yes No Yes Yes Yes No 2 axes Yes Yes No Yes Yes Yes No 4 axes Relay Unit for Servo CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 Yes Yes No Yes Yes Yes Yes Yes Yes No Current consumption (A) Model 5V 26 V system system 1 unit number’s words 2 unit numbers’ words 1 unit number’s words 2 unit numbers’ words 0.25 --- CS1W-NC113 0.25 --- CS1W-NC213 0.36 --- CS1W-NC413 0.25 --- CS1W-NC133 0.25 --- CS1W-NC233 0.36 --- CS1W-NC433 For use with the CS1W-NC1@3 Number of axes supported: 1 XW2B-20J6-1B For use with the CS1W-NC2@3/ NC4@3 Number of axes supported: 2 XW2B-40J6-2B For use with the CS1W-NC@@3 Number of axes supported: 2, with communications support For use with the CS1W-NC113 CS1 Special I/O Units Connectable Servo Drive: G5 Series, G Series, W Series *, or SMARTSTEP 2 Number of axes supported: 1 Connectable Servo Drive: SMARTSTEP Junior or A Series Open-collector output For use with the CS1W-NC213/ NC413 Servo Relay Unit Connecting Cable (Position Control Unit end) For use with the CS1W-NC133 Connectable Servo Drive: G5 Series, G Series, W Series *, or SMARTSTEP 2 Number of axes supported: 2 Connectable Servo Drive: SMARTSTEP Junior or A Series Connectable Servo Drive: G5 Series, G Series, W Series *, or SMARTSTEP 2 Number of axes supported: 1 Connectable Servo Drive: SMARTSTEP Junior or A Series Line-driver outputs Connectable Servo Drive: G5 Series, G Series, W Series *, or SMARTSTEP 2 For use with the CS1W-NC233/ NC433 Connectable Servo Drive: SMARTSTEP Junior or A Series * W-series is the discontinuation model in March 2013. 36 No No. of unit numbers allocated Programmable Controllers CS1G/H Number of axes supported: 2 XW2B-40J6-4A Cable length: 0.5 m XW2Z-050J-A6 Cable length: 1 m XW2Z-100J-A6 Cable length: 0.5 m XW2Z-050J-A8 Cable length: 1 m XW2Z-100J-A8 Cable length: 0.5 m XW2Z-050J-A7 Cable length: 1 m XW2Z-100J-A7 Cable length: 0.5 m XW2Z-050J-A9 Cable length: 1 m XW2Z-100J-A9 Cable length: 0.5 m XW2Z-050J-A10 Cable length: 1 m XW2Z-100J-A10 Cable length: 0.5 m XW2Z-050J-A12 Cable length: 1 m XW2Z-100J-A12 Cable length: 0.5 m XW2Z-050J-A11 Cable length: 1 m XW2Z-100J-A11 Cable length: 0.5 m XW2Z-050J-A13 Cable length: 1 m XW2Z-100J-A13 ■ Position Control Unit with MECHATROLINK-II interface Mountable Racks Specifications Unit type CPU Rack C200HX/ HG/HE Expansion Number CS1W-BC I/O Rack of axes @@3 @@2 Product name Control output interface Position Control Unit with MECHATROLINK-II interface Control commands are sent using 2 axes MECHATROLINK-II communications. Direct operation from ladder 4 axes program. Control modes: Position control, speed control, 16 axes and torque control CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 SYSMAC BUS Slave Rack No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system CS1W-NC271 Yes Yes No Yes Yes Yes No 1 unit number’s words 0.36 --- CS1W-NC471 CS1W-NCF71 CS1 CPU Bus Unit MECHATROLINK-II To connect MECHATROLINK-II compliant devices (Yaskawa Electric Corporation) Cables The model numbers at the right are used to order from OMRON. Cable length: 0.5 m FNY-W6003-A5 Cable length: 1 m FNY-W6003-01 Cable length: 3 m FNY-W6003-03 Cable length: 5 m FNY-W6003-05 Cable length: 10 m FNY-W6003-10 Cable length: 20 m FNY-W6003-20 Cable length: 30 m FNY-W6003-30 MECHATROLINK-II Terminating resistance for MECHATROLINK-II (Yaskawa Electric Corporation) Terminator The model number at the right is used to order from OMRON. FNY-W6022 MECHATROLINK-II Communications repeater. Repeater (Yaskawa Electric Corporation) JEPMC-REP2000-E ■ Motion Control Units Mountable Racks Specifications Unit type Product name CPU Rack Control output Number CS1W-BC interface of axes @@3 @@2 C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 Longdistance Rack Expansion CS1W-BI Rack @@3 @@2 No. of unit SYSMAC numbers BUS Slave allocated Rack Yes Yes No Yes Yes Yes Model 5V system 26 V system No 5 unit numbers’ words 0.70 (1.00 A when a Teaching Box is connected) --- CS1W-MC421-V1 No 3 unit numbers’ words 0.60 (0.80 A when a Teaching Box is connected) --- CS1W-MC221-V1 Motion Control Unit (G-language programming) 4 axes Current consumption (A) Analog outputs 2 axes Yes Yes No Yes Yes CS1 Special I/O Units Teaching Box Yes --- --- --- Teaching Box Connecting Cable --- --- Cable length: 2 m ROM Cassette --- --- MC Terminal Block For 2 axes Conversion Unit * For 4 axes MC Terminal Block Conversion Unit Cable --- --- CV500-CN224 CVM1-MP702-V1 --- ----- CVM1-PRO01-V1 XW2B-20J6-6 XW2B-40J6-7 Cable length: 1 m XW2Z-100J-F1 * Simplifies I/O connector wiring. Programmable Controllers CS1G/H 37 ■ Serial Communications Boards/Serial Communications Units Mountable Racks Unit type Product name CPU Rack Specifications CS1W-BC @@3 @@2 Serial Two Communications RS-232C Board ports CS1 Inner Board CS1 CPU Bus Unit The following communications protocols can be selected for each port: protocol macro, host link, NT Link (1:N mode), serial gateway (*1), no protocol (* 2), or Modbus-RTU Slave (*3). Two RS-422A/ 485 ports *1. *2. *3. *4. *5. CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 No. of SYSMAC unit BUS Slave numbers allocated Rack Current consumption (A) *4 Yes Yes *4 Yes No Yes No No Yes No Yes No Yes No Model 5V 26 V system system *5 0.28 One RS-232C port and one RS-422A/ 485 port Serial Two Communications RS-232C Unit ports C200HX/ HG/HE Expansion I/O Rack --- CS1W-SCB21-V1 *5 0.36 --- CS1W-SCB41-V1 *5 0.29 --- CS1W-SCU21-V1 0.40 --- CS1W-SCU31-V1 --- No 1 unit number’s words Yes Yes No Yes Yes Yes No The serial gateway function is supported by Serial Communications Boards and Units with unit version 1.2 or later only. The Serial Communications Unit’s no-protocol function is supported by Serial Communications Units with unit version 1.2 or later only. In addition the CPU Unit must be unit version 3.0 or later. The Modbus-RTU Slave function is supported by Serial Communications Boards and Units with unit version 1.3 or later only. One Board can be mounted in the Inner Board slot of the CPU Unit. NT-AL001 Link Adapters consume an additional 0.15 A each when used. ■ EtherNet/IP Unit Specifications Unit type Product Communications name cable Mountable Racks CPU Rack Communications functions CS1W-BC C200HX/ HG/HE Expansion I/O Rack @@3 @@2 CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 No. of SYSMAC unit BUS Slave numbers allocated Rack Current consumption (A) Model 5V 26 V system system EtherNet/ IP Unit STP (shielded twisted-pair) Tag data link cable of category message service 5, 5e, or higher. CS1 CPU Bus Unit * Yes * Yes * Yes No * Yes * Yes No 1 unit number’s words 0.41 --- CS1W-EIP21 * Up to eight CS1W-EIP21 EtherNet/IP Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. ■ EtherNet Unit Mountable Racks Unit type Product name CPU Rack Specifications CS1W-BC C200HX/ HG/HE Expansion I/O Rack @@3 @@2 EtherNet Unit CS1 CPU Bus Unit ETN21 FINS communications service (TCP/IP and UDP/IP), FTP server function, socket service, 100BASE-TX mail send service, mail Cable reception (remote command reception), auto-adjustment of PLC’s internal clock, and server host name specification * Yes * Yes No CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 * Yes * Yes * Yes No. of SYSMAC unit BUS Slave numbers allocated Rack No 1 unit number’s words Current consumption (A) Model 5V 26 V system system 0.38 --- CS1W-ETN21 * Up to four CS1W-ETN21 Ethernet Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. 38 Programmable Controllers CS1G/H ● Industrial Switching Hubs Specifications Product name Appearance Functions No. of pors Failure detection 3 No 5 No 5 Yes Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation Industrial Switching Hubs Accessories Current Consumption (A) • Power supply connector • Power supply connector • Connector for informing error Model 0.22 W4S1-03B 0.22 W4S1-05B 0.22 W4S1-05C ■ Controller Link Units Mountable Racks CPU Rack Unit type Product name Specifications CS1W-BC Wired shielded twisted-pair cable *1 Controller Link Optical ring H-PCF Unit cable *2 CS1 CPU Bus Unit Optical ring GI cable *3 Controller Wired shielded twisted-pair Link Support cable *1 Board H-PCF optical model GI optical model @@3 @@2 *4 Yes *4 Yes *4 Yes *4 Yes C200HX/ HG/HE Expansion I/O Rack CS1 Expansion Rack CS1W-BI CS1 Longdistance Expansion Rack SYSMAC BUS Slave Rack @@3 @@2 No *4 Yes *4 Yes Yes No *4 Yes No *4 Yes *4 Yes Yes No *4 Yes No *4 Yes *4 Yes Yes No No. of unit numbers allocated 1 unit number’s words Current consumption (A) 5V 26 V system system 0.33 --- CS1W-CLK23 0.52 --- CS1W-CLK13 0.65 --- CS1W-CLK53 • CD-ROM × 1 *5 • Installation Guide (W467) × 1 • Communications Connector × 1 • • • • CD-ROM × 1 *5 Installation Guide (W467) × 1 Optical Fiber Cable Bracket × 1 Power Supply Connector × 1 Model 3G8F7-CLK23-E --- 3G8F7-CLK13-E 3G8F7-CLK53-E ● Controller Link Options Product name Specifications Relay Terminal Block for Wired Controller Link Unit Use for Wired Controller Link Units (set of 5). Controller Link Repeater Unit Wire-to-Wire Model CS1W-RPT01 PWR T/R1 T/R2 Wire-to-Optical (H-PCF) Model *2 Model CJ1W-TB101 These products are not mounted to the PLC. (They are installed individually on DIN Rail or with screws.) CS1W-RPT01 CS1W-RPT02 SL1 TER SW SW1 1 BAUD 2 RATE ON TER SW SL2 DC24V INPUT *1. *2. *3. *4. *5. Wire-to-Optical (GI) Model *3 CS1W-RPT03 Use the following special cable for shielded, twisted-pair cable. • ESVC0.5 × 2C-13262 (Bando Electric Wire: Japanese Company) • ESNC0.5 × 2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company) • ESPC 1P × 0.5 mm2 (Nagaoka Electric Wire Co., Ltd.: Japanese Company) • Li2Y-FCY2 × 0.56qmm (Kromberg & Schubert, Komtec Department: German Company) • 1 × 2 × AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company) • #9207 (Belden: US Company) When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link). • Up to four Pre-Ver. 1.2 Controller Link Units (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. • Up to eight Controller Link Units with unit version 1.2 or later (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. The CD-ROM contains the following software. • Controller Link (PCI) Driver • FinsGateway Version 2003 (PCI-CLK Edition) • FinsGateway Version 3 (PCI-CLK Edition) • Setup Diagnostic Utility • C Library Programmable Controllers CS1G/H 39 ● H-PCF Cables (For Controller Link and SYSMAC LINK) Product name Application and construction Specifications Black (1) (2) (3) (4) (5) (6) Optical Fiber Cable Optical Connectors (Crimp-cut) *1. *2. 40 Controller Link SYSMAC LINK SYSBUS 1. 2. 3. 4. Optical fiber single-core cord Tension member (plastic-sheathed wire) Filler (plastic) Filler surrounding signal wires (plastic, yarn, or fiber) 5. Holding tape (plastic) 6. Heat-resistant PV sheath Two-core optical cable with tension member Model 10 m S3200-HCCB101 Black 50 m S3200-HCCB501 Black 100 m S3200-HCCB102 Black 500 m S3200-HCCB502 Black 1,000 m S3200-HCCB103 Orange 10 m S3200-HCCO101 Orange 50 m S3200-HCCO501 Orange 100 m S3200-HCCO102 Orange 500 m S3200-HCCO502 Orange 1,000 m S3200-HCCO103 Controller Link: CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E 3G8F7-CLK12-EV1 *1 CS1W-RPT02 SYSMAC LINK:CS1W-SLK11 3G8F7-SLK11-E C200HW-SLK13/14 *1 Half-lock S3200-COCF2571 Controller Link: CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E 3G8F7-CLK12-EV1 *1 CS1W-RPT02 SYSMAC LINK:3G8F7-SLK11-E Full-lock S3200-COCF2071 *2 Discontinuation models. Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock Cable (S3200-COCF2571) or a H-PCF Optical Fiber Cable with Connectors (S3200-CN@@@-@@-@@). Programmable Controllers CS1G/H ● H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines) Applicable Appearance Model S3200-CN@@@-20-20 Controller Link SYSMAC LINK S3200-CN@@@-20-25 S3200-CN@@@-25-25 Note: Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished. • Cable Length • Optical Connector Assembly Tool The following cable lengths are available: 2 m, 5 m, 15 m, and 20 m. For lengths of 21 m or more, contact your OMRON sales representative. • Model Numbers (1) 2 m, 5 m, 10 m, 15 m, 20 m (2) 21 m or longer (e.g.) S3200-CN@@@-20-25 (1) (1 ) H-PCF Optical Fiber Cable (2) (e.g.) S3200-CN-20-20 (3) (1) ( 2) Cable length @@@ Length 201 2m 501 5m 102 10m 152 15m 202 20m (3) Specify the cable length in meters (3) Connectors (both ends) No. Product name Applicable Units This tool is used on site for mounting crimp-cut connectors and hard Optical plastic-clad silica optical Fiber fiber for optical Assembly transmission systems of Tool * C-series SYSBUS, SYSMAC LINK, and Controller Link. Model Maker CAK-0057 Sumitomo Electric Industries, Ltd. * There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing cables with pre-attached connectors or having a qualified technician assemble the cables. Connector lock 20 Full-lock 25 Half-lock Cable length ● GI Optical Cables A qualified technician must select, assemble, and install GI Optical Fiber Cable, so always let an optical cable specialist handle the GI cable. Usable Optical Fiber Cables and Optical Connectors • Optical fiber types: Graded, indexed, multi-mode, all quartz glass, fiber (GI-type AGF cable) • Optical fiber construction (core diameter/clad diameter): 62.5/125 µm or 50/125 µm • Optical fiber optical characteristics of optical fiber: Refer to the tables. • Optical connectors: ST connectors (IEC-874-10) • 50/125 µm AGF Cables Items Minimum Typical Numerical Aperture (N.A) --- 0.21 Transmission loss (dB) --- --- Connection loss (dB) Transmission band width (MHz·km) --- --- 500 --- Maximum Remarks --- --- 3.0Lf 0.5 km ≤ Lf 3.0 Lf + 0.2 0.2 km ≤ Lf ≤ 0.5 km 3.0 Lf + 0.4 Lf ≤ 0.2 km 1.0 λ = 0.8 µm, one location --- λ = 0.8 µm, Ta = 25°C λ = 0.85 µm (LD) Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak wavelength of the test light source. • 62.5/125 µm AGF Cables Items Minimum Typical Numerical Aperture (N.A) --- 0.28 Transmission loss (dB) --- --- Connection loss (dB) Transmission band width (MHz·km) --- --- 200 --- Maximum Remarks --- --- 3.5Lf 0.5 km ≤ Lf 3.5Lf + 0.2 0.2 km ≤ Lf ≤ 0.5 km 3.5Lf + 0.4 Lf ≤ 0.2 km 1.0 λ = 0.8 µm, one location --- λ = 0.8 µm, Ta = 25°C λ = 0.85 µm (LD) Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak wavelength of the test light source. Programmable Controllers CS1G/H 41 ■ SYSMAC LINK Units Mountable Racks CPU Rack Unit type Product name Specifications CS1W-BC C200HX/ HG/HE Expansion I/O Rack @@3 @@2 SYSMAC LINK Unit Coaxial (5C-2V cable) Optical (H-PCF cable) *2 SYSMAC LINK Support Board Data link and message communications functions *1 Yes *1 Yes *1 Yes *1 Yes No *1 Yes CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 *1 Yes No *1 Yes *1 Yes *1 Yes *1 Yes No. of unit SYSMAC BUS Slave numbers allocated Rack No Current consumption (A) 5V 26 V system system 0.48 --- CS1W-SLK21 0.47 --- CS1W-SLK11 1 unit number’s words No Coaxial 3G8F7-SLK21-E CS1 CPU Bus Unit The 3G8F7-SLK@@ SYSMAC LINK Support Board includes the FinsGateway communications middleware version 3. --- Optical (H-PCF cable) *2 F Adapter F Adapter Cover Model 3G8F7-SLK11-E ----- C1000H-CE001 One Adapter is included with each Coaxial-cable SYSMAC LINK Unit/Board. --- A Terminator must be installed at each node on the ends of the network. --- C1000H-COV01 Terminator --- *1. *2. C1000H-TER01 Up to four CS1W-SLK11/21 SYSMAC LINK Units can be mounted to the CPU Backplane and Expansion Backplanes of one PLC. When using wired optical (H-PCF) communications, use the H-PCF Cable or H-PCF Cable with pre-attached connectors. ■ FL-net Units Mountable Racks Unit type Product name Specifications CPU Rack CS1W-BC @@3 @@2 C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 Longdistance Rack Expansion CS1W-BI Rack @@3 @@2 No. of unit SYSMAC BUS Slave numbers allocated Rack Current consumption (A) Model 5V 26 V system system FL-net Unit CS1 CPU Bus Unit FL-net (OPCN-2) Ver. 2 specifications 100BASE-TX Cable * Yes * Yes No * Yes * Yes * Yes No 1 unit number’s words 0.38 --- CS1W-FLN22 * Up to four CS1W-FLN22 FL-net Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. 42 Programmable Controllers CS1G/H ■ DeviceNet Unit Mountable Racks Unit type Product name CPU Rack Communications functions Specifications CS1W-BC @@3 @@2 DeviceNet Unit CS1 CPU Bus Unit Functions as master and/or slave; allows control of 32,000 points max. per master. • Remote I/O Master communications (Fixed or user-set allocation) • Remote I/O Slave communications (Fixed or user-set allocation) • Message communications Yes CS1 Expansion CS1 Longdistance Rack Expansion CS1W-BI Rack @@3 @@2 C200HX/ HG/HE Expansion I/O Rack Yes No Yes Yes No. of unit SYSMAC BUS Slave numbers allocated Rack Yes Current consumption (A) Model 5V 26 V system system No 1 unit number’s words 0.29 --- CS1W-DRM21-V1 Maximum number of Units: 16 if Configurator is used ■ CompoNet Master Unit Specifications Unit type Product name Communications functions Mountable Racks Maximum number of I/O points per Master CPU Rack CS1W-BC @@3 @@2 CompoNet Master Unit CS1 Special I/O Unit Word Slave Units: 1,024 inputs and 1,024 outputs • Remote I/O (2,048 I/O points communications total) • Message Bit Slave Units: communications 256 inputs and 256 outputs (512 I/O points total) Yes C200HX/ HG/HE Expansion I/O Rack Yes No CS1 Expansion CS1 Long- SYSMAC distance Rack BUS Slave Expansion Rack CS1W-BI Rack @@3 @@2 Yes Yes Yes No No. of unit numbers allocated 1, 2, 4, or 8 unit numbers’ words (variable) Current consumption (A) Model 5V 26 V system system 0.40 --- CS1W-CRM21 ■ CompoBus/S Master Unit Specifications Unit type Product name Mountable Racks Maximum number Communications of I/O points per functions Master CPU Rack CS1W-BC @@3 @@2 CS1 Special I/O Unit CompoBus/ S Master Unit Remote I/O communications C200HX/ HG/HE Expansion I/O Rack CS1 Expansion CS1 Long- SYSMAC distance Rack BUS Slave Expansion CS1W-BI Rack Rack @@3 @@2 256 max. (128 inputs and 128 outputs) No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system 2 unit numbers’ words Yes Yes No Yes Yes Yes No 128 max. (64 inputs and 64 outputs) 0.15 --- CS1W-SRM21 1 unit number’s words ■ ID Sensor Units Mountable Racks Unit type Product name Connecting ID System Number of RW Heads External power supply CPU Rack CS1W-BC @@3 @@2 ID Sensor Units CS1 Expansion CS1 Longdistance Rack Expansion CS1W-BI Rack @@3 @@2 No. of SYSMAC unit BUS numbers Slave allocated Rack Current consumption (A) Model 5V 26 V system system * 1 Not required Yes Yes No Yes Yes Yes No 1 unit number’s words 0.26 0.13 CS1W-V680C11 2 24 VDC Yes Yes No Yes Yes Yes No 2 unit numbers’ words 0.32 --- CS1W-V680C12 1 Not required Yes Yes No Yes Yes Yes No 1 unit number’s words 0.26 0.12 CS1W-V600C11 2 24 VDC Yes Yes No Yes Yes Yes No 2 unit numbers’ words 0.32 --- CS1W-V600C12 V680-series RFID system CS1 Special I/O Unit C200HX/ HG/HE Expansion I/O Rack V600-series RFID system * The current consumption is 0.28 A when connected to the V680-H01. For details, refer to the V680 Series RFID System Catalog (Cat. No. Q151). Programmable Controllers CS1G/H 43 ■ GP-IB Interface Unit Mountable Racks CPU Rack Unit type Product name Specifications CS1W-BC @@3 @@2 * Yes * Yes CS1 Expansion Rack C200HX/ HG/HE Expansion I/O Rack CS1W-BI @@3 @@2 * Yes * Yes CS1 Longdistance Expansion Rack SYSMAC BUS Slave Rack Yes No No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system GP-IB Interface Unit CS1 Special I/O Unit Master or slave mode provided. No 1 unit number’s words 0.33 --- CS1W-GPI01 * Up to four GP-IP Interface Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC. ■ SPU Unit (High-speed Data Storage Unit) Mountable Racks Specifications CPU Rack Unit type Product name PC Card slot SPU Unit (High-speed Data Storage Unit) 1 PC Card Type II slot Insert an OMRON HMC-EF@@@ to use the Memory Card. Ethernet LAN port CS1W-BC C200HX/ HG/HE Expansion I/O Rack @@3 @@2 CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 SYSMAC BUS Slave Rack Yes No Yes Yes Yes No Model 5V 26 V system system 1 port (10/100 BASE-TX) Yes Current consumption (A) 0.56 --- CS1W-SPU01-V2 0.70 --- CS1W-SPU02-V2 1 unit number’s words 2 ports (10/100 BASE-TX) SPUConsole Support Software * Functions: Setting the High-speed Data Storage Unit's unit settings, sampling settings, etc. (The software is required to make the High-speed Data Storage Unit's settings.) OS: Windows 7/Windows 8/ Windows 8.1/Windows 10 SPU Unit SPU Data Management Middleware Functions: Automatically uploads collected data files from the SPU Unit to the computer, and can also register the data in a database. OS: Windows XP/ Windows Vista/ Windows 7/Windows 8 --- Flash memory: 128 MB --- --- HMC-EF183 --- --- HMC-EF283 --- --- HMC-EF583 --- --- HMC-AP001 CS1 CPU Bus Unit Memory Cards Flash memory: 256 MB Flash memory: 512 MB --- Note: A memory Card is required to collect data. Memory Card Adapter (for a computer’s PCMCIA slot) * SPU-Console version lower than version 2.0 cannot be connected to SPU Units with unit version 2.0 or later. 44 No. of unit numbers allocated Programmable Controllers CS1G/H --- WS02-SPTC1-V2 1 license WS02-EDMC1-V2 5 licenses WS02-EDMC1-V2L05 C200H Special I/O Units ■ Temperature Sensor Units Specifications Unit type Product name I/O points Signal range selection Mountable Racks CPU Rack Signal range ConverExternal sion connection speed CS1W-BC @@3 @@2 C200H Special I/O Unit Thermocouple K, J 4 4 Tempera- inputs common ture Sensor Units 4 4 inputs common 4.8 s max. Removable (when 4 terminal inputs block are used per Unit) Thermometer JPt100 Thermometer Pt100 4 4 inputs common CS1 Expansion CS1 LongRack distance Expansion CS1W-BI Rack @@3 @@2 C200HX/ HG/HE Expansion I/O Rack No. of SYSMAC unit BUS numbers Slave allocated Rack Yes No Yes Yes No No Yes Yes No Yes Yes No No Yes Yes No Yes Yes No No Yes 1 unit number’s words Current consumption (A) Model 5V 26 V system system 0.45 --- C200H-TS001 0.45 --- C200H-TS101 0.45 --- C200H-TS102 ■ Analog Input Units Specifications Product Unit type name Signal I/O range points selection Analog Input Units C200H Special I/O Unit 8 8 cominputs mon Signal range Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongConverResoExternal HG/HE distance Rack sion lution connection Expansion Expansion CS1W-BC CS1W-BI speed I/O Rack Rack @@3 @@2 @@3 @@2 1 to 5 V, 4 to 20 mA, 1 ms/ 1/4000 0 to 10 V, input -10 to 10 V Removable terminal Yes block No Yes Yes No No Current No. of consumption SYSMAC unit (A) BUS numbers Slave allocated 5V 26 V Rack system system Yes 1 unit number’s words 0.10 0.10 Model C200H-AD003 ■ Analog Output Units Specifications Unit type Product name Analog Output Units C200H Special I/O Unit I/O points Signal range selection Signal range Mountable Racks CS1 CPU Rack C200HX/ Expansion CS1 LongConverRack HG/HE distance ResoluExternal sion tion connection Expansion Expansion speed CS1W-BC CS1W-BI I/O Rack Rack @@3 @@2 @@3 @@2 8 8 indepenoutputs dent 1 to 5 V, 1 ms/ 0 to 10 V, 1/4000 output -10 to 10 V 8 8 indepenoutputs dent 4 to 20 mA 1/4000 1 ms/ output Yes No Yes Yes No No No. of SYSMAC unit BUS numbers Slave allocated Rack Yes Removable terminal block Current consumption (A) Model 5V 26 V system system 0.10 0.20 C200H-DA003 0.10 0.25 C200H-DA004 1 unit number’s words Yes No Yes Yes No No Yes ■ Analog I/O Units Specifications Unit type Product name Analog I/O Units C200H Special I/O Unit I/O points Signal range selection Signal range CS1 CPU Rack C200HX/ Expansion CS1 LongConverRack HG/HE distance ResoluExternal sion Expansion Expansion tion connection speed CS1W-BC CS1W-BI I/O Rack Rack @@3 @@2 @@3 @@2 2 independent 1 to 5 V, 0 to 10 V, 1 ms/ 1/4000 -10 to 10 V, input 4 to 20 mA 2 2 indepenoutputs dent 1 to 5 V, 0 to 10 V, 1 ms/ 1/4000 -10 to 10 V, output 4 to 20 mA 2 inputs Mountable Racks Removable terminal Yes block No Yes Yes No No No. of SYSMAC unit BUS numbers Slave allocated Rack Yes 1 unit number’s words Programmable Controllers Current consumption (A) Model 5V 26 V system system 0.10 0.20 C200H-MAD01 CS1G/H 45 ■ Temperature Control Units Specifications Unit type Product name No. of loops Temperature Control Units C200H Special I/O Unit Mountable Racks CS1 Expansion CS1 LongCPU Rack C200HX/ SYSMAC Rack Temperature HG/HE distance Control output BUS Slave sensor inputs Expansion Expansion CS1W-BC CS1W-BI Rack I/O Rack Rack @@3 @@2 @@3 @@2 No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system Thermocouples Open-collector 2 loops (R, S, K, J, T, E, NPN outputs B, N, L, or U) (pulses) Yes No Yes Yes No No Yes 0.33 --- C200H-TC001 Thermocouples Voltage 2 loops (R, S, K, J, T, E, outputs B, N, L, or U) (pulses) Yes No Yes Yes No No Yes 0.33 --- C200H-TC002 Thermocouples Current 2 loops (R, S, K, J, T, E, outputs B, N, L, or U) (linear) Yes No Yes Yes No No Yes 0.33 --- C200H-TC003 2 loops Platinum resistance thermometers (JPt00, Pt100) ON/OFF transistor outputs (pulses) Yes No Yes Yes No No Yes 0.33 --- C200H-TC101 2 loops Platinum resistance thermometers (JPt00, Pt100) ON/OFF voltage outputs (pulses) Yes No Yes Yes No No Yes 0.33 --- C200H-TC102 2 loops Platinum resistance thermometers (JPt00, Pt100) ON/OFF current outputs (linear) Yes No Yes Yes No No Yes 0.33 --- C200H-TC103 Connecting Cable length: 2 m Cables Cable length: 4 m 1 unit number’s words --- C200H-CN225 --- C200H-CN425 ■ Heat/Cool Temperature Control Units Specifications Unit type Product name No. of loops Heat/Cool Temperature Control Units C200H Special I/O Unit Temperature sensor inputs Mountable Racks Control output Heating output: Voltage output Thermocouples (pulses), 2 loops (R, S, K, J, T, E, Cooling B, N, L, or U) output: Open-collector NPN outputs (pulses) CS1 Expansion CS1 LongCPU Rack C200HX/ SYSMAC Rack HG/HE distance BUS Slave Expansion Expansion CS1W-BC CS1W-BI Rack I/O Rack Rack @@3 @@2 @@3 @@2 Yes No Connecting Cable length: 2 m Cables Cable length: 4 m 46 Programmable Controllers CS1G/H Yes Yes No No Yes No. of unit numbers allocated 1 unit number’s words Current consumption (A) Model 5V 26 V system system 0.33 --- C200H-TV002 --- C200H-CN225 --- C200H-CN425 ■ PID Control Units Specifications Unit type Product name No. of loops PID Control Units C200H Special I/O Unit Temperature sensor input Voltage input/ current input 2 loops (4 to 20 mA, 1 to 5 V, 0 to 5 V, or 0 to 10 V) Mountable Racks Control output Current outputs (linear) CS1 CPU Rack C200HX/ Expansion CS1 LongSYSMAC Rack HG/HE distance BUS Slave Expansion Expansion CS1W-BC CS1W-BI Rack I/O Rack Rack @@3 @@2 @@3 @@2 Yes No Yes Yes No Connecting Cable length: 2 m Cables Cable length: 4 m No Yes No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system 1 unit number’s words 0.33 --- C200H-PID03 --- C200H-CN225 --- C200H-CN425 ■ High-speed Counter Units Specifications Unit type Product name Number Encoder A and of B input, pulse counters input, Z signal High-speed Counter Units C200H Special I/ O Unit Voltage input: 12 or 24 VDC Mountable Racks CS1 Expansion CS1 LongCPU Rack C200HX/ Maximum SYSMAC Rack HG/HE distance counting BUS Slave Expansion Expansion CS1W-BC CS1W-BI speed Rack I/O Rack Rack @@3 @@2 @@3 @@2 Current consumption (A) Model 5V 26 V system system 50 kHz 2 Yes RS-422 line driver No. of unit numbers allocated No Yes Yes No No Yes 1 unit number’s words 0.40 --- C200H-CT021 75 kHz Programmable Controllers CS1G/H 47 ■ ASCII Units Mountable Racks Unit type Product name CS1 Expansion CS1 LongCPU Rack C200HX/ SYSMAC Rack HG/HE distance BUS Slave Expansion Expansion CS1W-BC CS1W-BI Rack I/O Rack Rack @@3 @@2 @@3 @@2 Specifications No. of unit numbers allocated Current consumption (A) Model 5V 26 V system system ASCII Units User memory area: 200 Kbytes Shared memory: Provided (general-purpose area: 90 words) RS-232C x 2 ports C200H Special I/O Unit RS-422A Adapter Yes No Converts RS-232C to RS-422A/ RS-485 format. RS-232C/RS-422A One RS-232C port Link Adapter One RS-422 terminal block 48 Programmable Controllers CS1G/H Yes Yes No No Yes 1 unit number’s words 0.25 --- C200H-ASC11 --- --- CJ1W-CIF11 --- --- NT-AL001 Replacing C200H I/O Units This section shows the corresponding CS1 I/O models and notes for replacing C200H I/O Units. 16-point DC Input Units Item Model number Description 64-point DC Input Units C200H I/O Unit Corresponding CS1 I/O Unit C200H-ID212 CS1W-ID211 Description Notes C200H I/O Unit Corresponding CS1 I/O Unit C200H-ID218 CS1W-ID231 32-point DC Input Units with connectors. The connectors, the pin arrangement, and the input specifications are the same. Item Model number Description Model number Description The internal 5-V current consumption increases (from 100mA to 150mA). Check that the increased current is within the range of the power supply. C200H I/O Unit Corresponding CS1 I/O Unit C200H-ID216 CS1W-ID231 32-point DC Input Units with connectors. The connectors and the pin arrangement are the same. The input current increases, allowing use with a wider range of devices. There are 2 commons instead of 1. Connect where necessary. Notes C200H-ID219 CS1W-ID261 64-point DC Input Units with connectors. The connectors, the pin arrangement, and the input specifications are the same. The internal 5-V current consumption increases (from 120mA to 150mA). Check that the increased current is within the range of the power supply. The input specifications change (e.g., the impedance decreases and the input current increases from 4.1mA to 6mA.) Check that correct operation is possible in cases where changes in input specifications may influence operation. The internal 5-V current consumption increases (from 100mA to 150mA). Check that the increased current is within the range of the power supply. C200H I/O Unit Corresponding CS1 I/O Unit C200H-ID217 CS1W-ID261 64-point DC Input Units with connectors. The connectors and the pin arrangement are the same. The input current increases, allowing use with a wider range of devices. There are 4 commons instead of 2. Connect where necessary. Notes 32-point DC Input Units (cntd.) Item Corresponding CS1 I/O Unit There are 4 commons instead of 2. Connect where necessary. There are 2 commons instead of 1. Connect where necessary. Notes C200H I/O Unit 64-point DC Input Units (cntd.) 32-point DC Input Units Model number Description The impedance increases (from 3kΩ to 3.3kΩ). Check that correct operation is possible in cases where increased impedance may influence operation. The internal 5-V current consumption increases (from 10mA to 100mA). Check that the increased current is within the range of the power supply. Item Model number 16-point DC Input Units with terminal blocks The terminal arrangement must be changed. Notes Item The input specifications change (e.g., the impedance decreases and the input current increases from 4.1mA to 6mA.) Check that correct operation is possible in cases where changes in input specifications may influence operation. The internal 5-V current consumption increases (from 100mA to 150mA). Check that the increased current is within the range of the power supply. 16-point Sinking Transistor Output Units Item Model number Description C200H I/O Unit Corresponding CS1 I/O Unit C200H-OD212 CS1W-OD211 16-point Transistor Output (sinking) Units with terminal blocks. The output current capacity increases (from 0.3A per point and 4.8A per Unit to 0.5A per point and 8A per Unit). The rated voltage range also increases (from 24V to any voltage in the range 12 to 24V.) The terminal arrangement must be changed. Notes The output specifications change. Check that correct operation is possible in cases where changes in output specifications may influence operation. (Residual voltage increases from 0.8V to 1.5V, ON response time increases from 0.1ms to 0.5ms, OFF response time increases from 0.3ms to 1ms.) Programmable Controllers CS1G/H 49 C200H??????????????????? 16-point Sourcing Transistor Output Units Item Model number Description C200H I/O Unit Corresponding CS1 I/O Unit C200H-OD21A * CS1W-OD212 16-point Transistor Output (sourcing) Units with terminal blocks. 32-point Sourcing Transistor Output Units Item Model number Description The terminal arrangement must be changed. Notes The internal 5-V current consumption increases (from 160mA to 170mA). The external 24-V power supply current also increases (from 35mA to 40mA). Check that the increased current is within the range of the power supply. There are no alarm output contacts. Use the alarm bits in the Auxiliary Area. * Discontinuation models in March 2015. Notes Model number Description Corresponding CS1 I/O Unit C200H-OD218 CS1W-OD231 Notes The output specifications change. Check that correct operation is possible in cases where changes in output specifications may influence operation. (Residual voltage increases from 0.8V to 1.5V, ON response time increases from 0.1ms to 0.5ms, OFF response time increases from 0.3ms to 1ms.) 64-point Sinking Transistor Output Units Item Description C200H I/O Unit Corresponding CS1 I/O Unit C200H-OD219 CS1W-OD261 64-point Transistor Output (sinking) Units with connectors. The connectors and the pin arrangement are the same. The output current capacity increases (from 100mA to 0.3A per point, 1.6A per common, and 6.4A per Unit). The load voltage range changes from 4.5 to 26.4V to 10.2 to 26.4V. There are 4 commons instead of 2. Connect where necessary. 32-point Transistor Output (sinking) Units with connectors. The connectors and the pin arrangement are the same. The output current capacity increases (from 100mA to 0.5A per point, 2.5A per common, and 5A per Unit). The load voltage range changes from 4.5 to 26.4V to 10.2 to 26.4V. There are 2 commons instead of 1. Connect where necessary. CS1W-OD232 * C200H-OD21B was discontinued at the end of March 2016. Model number C200H I/O Unit C200H-OD21B * 32-point Transistor Output (sourcing) Units with connectors. The connectors and the pin arrangement are the same. The internal 5-V current consumption increases (from 180mA to 270mA). Check that the increased current is within the range of the power supply. 32-point Sinking Transistor Output Units Item Corresponding CS1 I/O Unit There are 2 commons instead of 1. Connect where necessary. The output capacity changes (from 1A per point and 4A per Unit to 0.5A per point and 5A per Unit). Check that correct operation is possible in cases where changes in output capacity may influence operation. The output specifications change. Check that correct operation is possible in cases where changes in output specifications may influence operation. (Residual voltage increases from 0.8V to 1.5V, ON response time increases from 0.1ms to 0.5ms, OFF response time increases from 0.3ms to 1ms.) C200H I/O Unit Notes The output specifications change. Check that correct operation is possible in cases where changes in output specifications may influence operation. (Residual voltage increases from 0.8V to 1.5V, ON response time increases from 0.1ms to 0.5ms, OFF response time increases from 0.4ms to 1ms.) Replacement is not possible for applications with an output load range of 4.5 to 10.2V. The output specifications change. Check that correct operation is possible in cases where changes in output specifications may influence operation. (Residual voltage increases from 0.8V to 1.5V, ON response time increases from 0.1ms to 0.5ms, OFF response time increases from 0.4ms to 1ms.) The internal 5-V current consumption increases (from 270mA to 390mA). Check that the increased current is within the range of the power supply. Replacement is not possible for applications with an output load range of 4.5 to 10.2V. 16-point 100-VAC Input Units The internal 5-V current consumption increases (from 180mA to 270mA). Check that the increased current is within the range of the power supply. Item Model number Description C200H I/O Unit Corresponding CS1 I/O Unit C200H-IA122/122V CS1W-IA111 16-point 100-VAC Input Units with terminal blocks. 100-VDC input also possible. The terminal arrangement must be changed. Notes The input specifications change. Check that correct operation is possible in cases where changes in input specifications may influence operation. (ON voltage increases from 60VAC min. to 65VAC min. and the input impedance (50Hz) increases from 9.7kΩ to 10kΩ.) The internal 5-V current consumption increases (from 10mA to 110mA). Check that the increased current is within the range of the power supply. 50 Programmable Controllers CS1G/H MEMO 51 OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com. br OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime P062I-E-02 Note: Specifications are subject to change. © 2018 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
CS1G-CPU42H 价格&库存

很抱歉,暂时无法提供与“CS1G-CPU42H”相匹配的价格&库存,您可以联系我们找货

免费人工找货
CS1G-CPU42H
  •  国内价格 香港价格
  • 1+19181.134911+2379.41088

库存:3