System Design Guide
System Configuration .........................................................................................2
Dimensions/Mounting Dimensions .....................................................................9
General Specifications......................................................................................11
Common Specifications for CPU Units .............................................................12
Current Consumption for Power Supply Units ..................................................15
1
System Configuration
■ Basic System Configuration
CS1 Inner Boards
Loop Control Board
CS1W-LCB01/05
Serial Communications Board
CS1W-SCB21-V1
CS1W-SCB41-V1
CS1 CPU Units
CS1 Power Supply Units
CS1H-CPU@@H
CS1G-CPU@@H
C200HW-PA204C
C200HW-PA204
C200HW-PA204S
C200HW-PA204R
C200HW-PA209R
C200HW-PD024
C200HW-PD025
CS1 CPU Backplane
Programming Devices
CX-One
(e.g., CX-Programmer)
Programming Console
Cable for
Peripheral Port
CPU Rack
For both CS1 and C200H Units
CS1W-BC@@3
(2, 3, 5, 8, or 10 slots)
Cable for Personal
Computer
CS1W-CN226/626
RUN
ERR/ALM
INH BKUP
PRPHL COMM
SYSMAC
CS1D-CPU67S
PROGRAMMABLE CONTROLLER
MCPWR
BUSY
OPEN
or
PERIPHERAL
For CS1 Unit only
CS1W-BC@@2
(2, 3, 5, 8, or 10 slots)
Note: Cannot be used for C200H
Unit.
Programmable
Terminal (PT)
PORT
NS Series
Basic I/O Units
Special I/O Units
CPU Bus Units
Memory Card
HMC-EF183
CS1 I/O
Connecting Cable
Expansion Racks
CS1W-CN@@3
CS1 Expansion Rack
(30 cm, 70 cm, 2 m, 3 m,
5 m, 10 m, 12 m)
XW2Z-200T/500T
Configuration Units
CS1 Expansion
Backplanes
CS1 I/O
Connecting Cable
Power Supply Unit
CS1 Expansion Rack
For both CS1 and C200H Units
CS1W-BI@@3
(3, 5, 8, or 10 slots)
or
Programmable Controllers
Power Supply Unit
CS1 I/O
Connecting Cable
CS1 Expansion Rack
RS-422A Adapter
CJ1W-CIF11
Configuration Units
2
RS-232C Cable for
IBM PC/AT or
compatible
computers
XW2Z-200S/500S-CV
Configuration Units
For CS1 Unit only
CS1W-BI@@2
(3, 5, 8, or 10 slots)
Note: Cannot be used for C200H
Unit.
RS-232C Cable
for PT
CS1G/H
Power Supply Unit
■ Configuration Units
CS1 Basic I/O Units
8-point Units
16-point Units
32-point Units
64-point Units
96-point Units
Input Units
---
● DC Input Unit
CS1W-ID211
● AC Input Unit
CS1W-IA@11
● DC Input Unit
CS1W-ID231
● DC Input Unit
CS1W-ID261
● DC Input Unit
CS1W-ID291
● Transistor Output Units
CS1W-OD26@
● Transistor Output Units
CS1W-OD29@
(32 inputs, 32 outputs)
● DC Input/Transistor
Output Units
CS1W-MD26@
(32 inputs, 32 outputs)
● TTL I/O Unit
CS1W-MD561
(48 inputs, 48 outputs)
● DC Input/Transistor
Output Units
CS1W-MD29@
Output Units
● Triac Output Unit
CS1W-OA201
● Relay Contact Output Unit
(independent commons)
CS1W-OC201
● Transistor Output Units
● Transistor Output Units
CS1W-OD21@
CS1W-OD23@
● Triac Output Unit
CS1W-OA211
● Relay Contact Output Unit
CS1W-OC211
I/O Units
---
---
---
Other Units
● Safety Relay Unit
CS1W-SF200
● Interrupt Input Unit
CS1W-INT01
● Quick-response Input Unit
CS1W-IDP01
● B7A Interface Units
(32 inputs)
CS1W-B7A12
(32 inputs)
CS1W-B7A02
(16 inputs, 16 outputs)
CS1W-B7A21
● B7A Interface Units
(32 inputs, 32 outputs)
CS1W-B7A22
---
C200H Basic I/O Units and C200H Group-2 High-density I/O Units
● Input Units
C200H-I@@@@
(Including group-2 highdensity input units)
● Output Units
C200H-O@@@@
(Including group-2 highdensity output units)
● Interrupt Input Unit
C200HS-INT01
● Analog Timer Unit
C200H-TM001
● B7A Interface Units
C200H-B7A@@@
CS1 Special I/O Units, CPU Bus Units, and Inner Boards
■ Temperature Sensor Input Units
(Process I/O Units)
CS1W-PTS@@
■ Analog Input Units
● Analog Input Units
CS1W-AD@@@(-V1)
● Isolated-type DC Input Units
(Process I/O Units)
CS1W-PDC@@
CS1W-PTW01
CS1W-PTR0@
■ Analog Output Units
● Analog Output Units
CS1W-DA0@@
● Isolated-type Control Output
Units
(Process I/O Units)
CS1W-PMV0@
■ Analog I/O Units
CS1W-MAD44
■ Isolated-type Pulse Input Units
(Process I/O Units)
CS1W-PPS01
■ Loop Control Board
CS1W-LCB0@
■ High-speed Counter Units
CS1W-CT0@@
■ Customizable Counter Units
CS1W-HCP22-V1
CS1W-HCA@2-V1
CS1W-HIO01-V1
■ Position Control Units
CS1W-NC@@3
■ Position Control Unit with
MECHATROLINK-II interface
CS1W-NCF71
CS1W-NC@71
■ Motion Control Units
CS1W-MC@21-V1
■ Motion Control Unit with
MECHATROLINK-II interface
CS1W-MCH71
■ I/O Units
(Special I/O Units)
C200H-ID@@@
C200H-OD@@@
C200H-MD@@@
■ Temperature Sensor Units
C200H-TS@@@
■ Analog Input Units
C200H-AD@@@
■ Analog Output Units
C200H-DA@@@
■ Analog I/O Units
C200H-MAD01
■ Temperature Control Units
C200H-TC@@@
■ Heat/Cool Control Units
C200H-TV@@@
■ PID Control Units
C200H-PID0@
■ High-speed Counter Units
C200H-CT@@@(-V1)
■ Cam Positioner Unit
C200H-CP114
■ Position Control Units
C200HW-NC@@3
■ Motion Control Units
C200H-MC221
■ Serial Communications Units/
Serial Communications Boards
CS1W-SCB@1-V1
CS1W-SCU@1-V1
■ EtherNet/IP Unit
CS1W-EIP21
■ Ethernet Unit
CS1W-ETN21
■ Controller Link Units
CS1W-CLK@3
■ SYSMAC Link Units
CS1W-SLK@1
■ FL-net Unit
CS1W-FLN22
■ DeviceNet Units
CS1W-DRM21-V1
■ CompoNet Master Unit
CS1W-CRM21
■ CompoBus/S Master Unit
CS1W-SRM21
■ ID Sensor Units
CS1W-V680C1@
CS1W-V600C1@
■ GP-IB Interface Unit
CS1W-GPI01
■ High-speed Data Storage Unit
CS1W-SPU0@-V2
C200H Special I/O Units
■ DeviceNet Master Unit
C200HW-DRM21-V1
■ CompoBus/S Master Unit
C200HW-SRM21-V1
■ PC Link Unit
C200H-LK401
■ SYSBUS Bus Remote I/O Master
Units
C200H-RM@@@(-PV1)
■ ID Sensor Units
C200H-IDS01-V1
■ ASCII Units
C200H-ASC@@
Note: Including models whose production are discontinued.
Programmable Controllers
CS1G/H
3
■ CS1 CPU Rack
A CS1 CPU Rack consists of a CPU Unit, Power Supply Unit, and Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus
Units).
CS1 CPU Backplane
CS1W-BC@@@ (See note.)
CS1 CPU Unit
CS1G/H-CPU@@H
Power Supply Unit
C200HW-P@@@@(@)
RUN
ERR/ALM
INH BKUP
PRPHL COMM
SYSMAC
CS1D-CPU67S
PROGRAMMABLE CONTROLLER
MCPWR
BUSY
OPEN
CPU Rack
PERIPHERAL
PORT
Basic I/O Units
Special I/O Units
CPU Bus Units
Note: C200H Units cannot be used on the CPU Rack or Expansion Racks
if a CS-series-only CPU Backplane (CS1W-BC@@3) is used.
● Required Units
Rack
Unit name
CPU Rack
Required number of units
CS1 CPU Backplane (CS1W-BC@@@)
1
Power Supply Unit
1
CPU Unit
1
Maximum Number of Configuration Units
Varies by backplane model
● Types of Units
In the CS Series, Units are classified into the following three types. The number of Racks differs depending on the type.
Type
Appearance (example)
Basic I/O Units
CS1 Basic I/O Units
C200H Basic I/O Units
Description
Unit recognition method
No. of Units
Units with contact inputs and contact
outputs.
In the CS1 System, CS1
Basic I/O Units, C200H
Basic I/O Units, and
Group-2 High-density I/O
Units are identified by
their mounting positions
(Rack and slot).
The Units mounted must
not exceed the maximum
I/O capacity of the CPU
Unit.
Special I/O Units provide more
advanced functions than do Basic I/O
Units, including I/O other than contact
inputs and contact outputs.
Examples of Special I/O Units are
Analog I/O Units and High-speed
Counter Units. They differ from CPU
Bus Units (including Network
Communications Units) in having a
smaller area for exchanging data with
the CPU Unit.
Recognized by the CPU
Unit according to the unit
number (CS-series
Special I/O Units: 0 to 95,
C200J Special I/O Units:
0 to 9, or 0 to 15) set with
the rotary switches on the
front panel.
CS-series Special I/O
Units: 96 Units max.;
C200H Special I/O Units:
10 or 16 Units max. (From
1 to 4 unit numbers are
assigned per Unit,
depending on the model
of the Unit.)
CPU Bus Units exchange data with
the CPU Unit via the CPU Bus.
Examples of CPU Bus Units are
Network Communications Units and
Serial Communications Units.
They differ from Special I/O Units in
having a larger area for exchanging
data with the CPU Unit.
Recognized by the CPU
Unit according to the unit
number (0 to F) set with
the rotary switch on the
front panel.
A maximum of 16 Units
can be mounted.
C200H Group-2 High-density
I/O Units
Special I/O Units
CS1 Special I/O Units
C200H Special I/O Units
CPU Bus Units
CS1 CPU Bus Units
4
Programmable Controllers
CS1G/H
■ CS1 Expansion Racks
● CS1 CPU Racks and Expansion Racks
Use this system configuration for an expansion of 12 m or less.
Expansion Racks Configuration
CPU Rack
Unit name
CS1 Expansion Backplane
CS1W-BI@@@
12 m
CS1 I/O
Connecting Cable
CS1W-CN@@3
CS1 Expansion Backplane
CS1W-BI@@@
CS1 I/O
Connecting Cable
CS1W-CN@@3
CS1 Expansion Backplane
CS1W-BI@@@
CS1
Expansion
Rack
CS1
Expansion
Rack
CS1
Expansion
Rack
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
The maximum
number of
Expansion Racks: 7
CS1 I/O
Connecting Cable
CS1W-CN@@3
Required number of units
Expansion
Backplane
(CS1W-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
Maximum Number
of Configuration
Units
Varies by backplane model
• Cable
Cable name
Required number of Cables
CS1 I/O Connecting
Cable
(CS1W-CN@@3)
One required for each
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
Programmable Controllers
CS1G/H
5
● When Using a C200HX/HG/HE Expansion I/O Rack
It is possible to connect to an existing C200HX/HG/HE Expansion I/O Rack.
CS1 CPU Rack, CS1 Expansion Racks, and C200HX/HG/HE Expansion I/O Racks
Expansion Racks Configuration
• CS1 Expansion Racks
CPU Rack
Unit name
CS1 I/O Connecting Cable
CS1W-CN@@3
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
12 m
CS1 to C200H I/O
Connecting Cable
CS1W-CN@@1
C200HX/HG/HE Expansion
I/O Rack
Power Supply Unit
C200HW-P@@@@(@)
C200H I/O
Connecting
Cable
C200H-CN@@1
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
C200HX/HG/HE Expansion
I/O Rack
Power Supply Unit
C200HW-P@@@@(@)
The maximum number of
Expansion Racks: 7 (C200HX/HG/HE Expansion I/O Racks :3)
CS1 Expansion Rack
(See note.)
CS1 Expansion
Backplane
CS1W-BI@@@
1
Power Supply Unit
1
Maximum Number of
Configuration Units
Varies by backplane model
• C200HX/HG/HE Expansion Racks
Unit name
Required number of units
C200HX/HG/HE
Expansion I/O
Backplane
(C200HW-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
Maximum Number of
Configuration Units
Varies by backplane model
• Cables
Cable name
Note: Multiple CS1 Expansion Racks can be connected, but the total number of Expansion Racks
must not exceed the maximum of 7. In addition, the Racks must be connected in order, with
CS1 Expansion Racks connected before C200HX/HG/HE Expansion I/O Racks.
Required number of units
Expansion Backplane
(CS1W-BI@@@)
Required number of cables
CS1 I/O Connecting
Cable
(CS1W-CN@@3)
Number of CS1 Expansion
Racks
CS1 to C200H I/O
Connecting Cable
(CS1W-CN@@1)
1
C200H I/O Connecting
Cable
(C200H-CN@@1)
Number of C200HX/HG/HE
Expansion I/O Racks
minus 1
CS1 CPU Rack and C200HX/HG/HE Expansion I/O Racks
Expansion Racks Configuration
• C200HX/HG/HE Expansion I/O Racks
CPU Rack
Unit name
CS1 to C200H I/O
Connecting Cable
CS1W-CN@@1
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
C200HX/HG/HE I/O
Expansion Rack
C200HX/HG/HE 12 m
Expansion
I/O Backplane
C200HW-BI@@@
C200H I/O
Connecting Cable
C200H-CN@@1
C200HX/HG/HE I/O
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
6
C200H I/O
Connecting Cable
C200H-CN@@1
C200HX/HG/HE I/O
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
Programmable Controllers
CS1G/H
The maximum number of Expansion Racks: 3
Power Supply Unit
C200HW-P@@@@(@)
Required number of units
C200HX/HG/HE
Expansion I/O
Backplane
(C200HW-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
Maximum Number of
Configuration Units
Varies by backplane model
• Cables
Cable name
Required number of cables
CS1 to C200H I/O
Connecting Cable
(CS1W-CN@@1)
1
C200H I/O Connecting
Cable
(C200H-CN@@1)
Number of C200HX/HG/HE
Expansion I/O Racks
minus 1
● Long-distance Expansion
Use this system configuration for an expansion of more 12 m. Expansion is possible by up to 50 m.
Using CS1 Connecting Cable and Long-distance Expansion Connecting Cable
CPU Rack
(Used for long-distance expansion.)
CS1 I/O Connecting Cable CS1W-CN@@3
0.7 m
CS1 Expansion Backplane
CS1W-BI@@@
I/O Control Unit (see note.)
CS1W-IC102
CS1 Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
Connecting Cable for Long-distance Expansion CV500-CN@@2
Connecting Cable for Long-distance Expansion CV500-CN@@2
CS1 Expansion Backplane
CS1W-BI@@@
I/O Interface Unit
CS1W-II102
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Backplane
CS1W-BI@@@
I/O Interface Unit
CS1W-II102
CS1 Expansion Rack
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit
CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
CS1 Expansion Backplane
CS1W-BI@@@
50 m
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit
CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
50 m
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit
CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Terminator *
Power Supply Unit
C200HW-P@@@@(@)
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit
CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
* Two Terminators (CV500-TER01) are provided with
the CS1W-IC102 I/O Control Unit.
The maximum number of Expansion Racks: 6 (In two levels)
CS1 Expansion Backplane
CS1W-BI@@@
Power Supply Unit
C200HW-P@@@@(@)
Terminator *
Note: If even one Long-distance Expansion Connecting Cable to be used, it is necessary for an
I/O Control Unit to be mounted to the CS1 Expansion Rack where the Cable is connected.
Expansion Racks Configuration
• CS1 Expansion Rack
Unit name
Required number of units
I/O Control Unit
(CS1W-IC102)
1
• CS1 Expansion Rack (Long-distance
expansion)
Unit name
Required number of units
CS1 Expansion
Backplane
(CS1W-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
I/O Interface Unit
(CS1W-II102)
One required for each
Expansion Rack
Maximum Number of
Configuration Units
Varies by backplane model
• Cable
Cable name
Required number of cables
CS1 I/O Connecting
Cable
(CS1W-CN@@3)
1
Connecting Cable for
Long-distance
Expansion
(CV500-CN@@2)
Number of CS1 Expansion
Racks minus 1
Programmable Controllers
CS1G/H
7
Using Long-distance Expansion Connecting Cable
I/O Control Unit
CS1W-IC102
CPU Rack
(Used for long-distance expansion.)
Connecting Cable for Long-distance Expansion CV500-CN@@2
Connecting Cable for Long-distance Expansion CV500-CN@@2
CS1 Expansion Backplane
CS1W-BI@@@
I/O Interface Unit
CS1W-II102
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Backplane
CS1W-BI@@@
I/O Interface Unit
CS1W-II102
CS1 Expansion Rack
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
CS1 Expansion Backplane
CS1W-BI@@@
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.) 50 m
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
50 m
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
CS1 Expansion Backplane
CS1W-BI@@@
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
Connecting Cable for Long-distance Expansion
CV500-CN@@2
I/O Interface Unit CS1 Expansion Rack
CS1W-II102
(Used for long-distance expansion.)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Terminator *
The maximum number of Expansion Racks: 7 (In two levels)
CS1 Expansion Backplane
CS1W-BI@@@
* Two Terminators (CV500-TER01) are provided
with the CS1W-IC102 I/O Control Unit.
Terminator *
CS1 CPU Rack
Unit name
I/O Control Unit
(CS1W-IC102)
Required number of units
1
Expansion Racks Configuration
• CS1 Expansion Rack (Long-distance
expansion)
Unit name
Required number of units
CS1 Expansion
Backplane
(CS1W-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
I/O Interface Unit
(CS1W-II102)
One required for each
Expansion Rack
Maximum Number of
Configuration Units
Varies by backplane model
• Cable
Cable name
Connecting Cable for
Long-distance
Expansion
(CV500-CN@@2)
8
Programmable Controllers
CS1G/H
Required number of cables
Number of Long-distance
Expansion Racks
Dimensions/Mounting Dimensions
(Unit: mm)
■ External Dimensions
■ Backplane Mounting Dimensions
● For 2 I/O Slots
4-M4
RUN
ERR
INH
COMM
198.5
POWER
SYSMAC C200HX
PROGRAMMABLE CONTROLLER
CPU64
H B
CPU Backplane
CS1W-BC023
157
A
145±0.3
D
W
172.3±0.3
A
B
W
H
D*
Note: An Expansion Backplane cannot be connected to a 2-slot CPU
Backplane.
CS1W-BC022/023
(2 slots)
172.3
145
198.5
157
123
● For 3, 5, 8, or 10 I/O Slots
CS1W-BC032/033
(3 slots)
246
118
260
132
123
Backplane model
CS1W-BC052/053
(5 slots)
316
118
330
132
123
CS1W-BC082/083
(8 slots)
421
118
435
132
123
CS1W-BC102/103
(10 slots)
491
118
505
132
123
6
135
(including 132
protrusion) *
118±0.3
CPU Backplane
66 min.
* The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit.
The depth is 111 mm for the C200HW-PA204C Power Supply Unit.
6
A±0.3
4-M4
A±0.3
80
6
6
135
(including 132
protrusion) *
118±0.3
Expansion Backplane
4-M4
W
* The CS1D Backplane has no protrusions.
Product name
CPU Backplanes
CS1
Expansion
Backplane
Expansion
Backplanes
C200HX/HG/HE
Expansion
Backplane
Model
A
W
CS1W-BC022/023
(2 slots)
172.3
198.5
CS1W-BC032/033
(3 slots)
246
260
CS1W-BC052/053
(5 slots)
316
330
CS1W-BC082/083
(8 slots)
421
435
CS1W-BC102/103
(10 slots)
491
505
CS1W-BI032/033
(3 slots)
246
260
CS1W-BI052/053
(5 slots)
316
330
CS1W-BI082/083
(8 slots)
421
435
CS1W-BI102/103
(10 slots)
491
505
C200HW-BI031
(3 slots)
175
189
C200HW-BI051
(5 slots)
245
259
C200HW-BI081-V1
(8 slots)
350
364
C200HW-BI101-V1
(10 slots)
420
434
Programmable Controllers
CS1G/H
9
■ Mounting Height
The mounted height of CPU Racks, Expansion Racks, and Slave
Racks is 118 to 153 mm, depending on I/O Units that are
mounted.
If Programming Devices or connecting cables are attached, the
additional dimensions must be taken into account. Allow sufficient
clearance in the control panel in which the PLC is mounted.
● CS1 I/O Connecting Cable
R
R ≥ 69 mm required
Note: Cable thickness: 8.6 mm dia.
● C200H I/O Connecting Cable
118 mm to 153 mm
180 mm to 223 mm
Note: When using Expansion Racks, the total
length of the I/O Connecting Cables
must be less than 12 m. When bending
an I/O Connecting Cables, provide at
least the minimum bending radius
shown in the following diagrams.
R ≥ 41 mm required
R
Note: Cable thickness: 5.1 mm dia.
● CS1 to C200H I/O Connecting Cable
R
R ≥ 41 mm required
Note: Cable thickness: 5.1 mm dia.
● Connecting Cable for Long-distance Expansion
R
R ≥ 80 mm required
Note: Cable thickness: 10 mm dia.
10
Programmable Controllers
CS1G/H
General Specifications
Specifications
Power Supply
Unit model
C200HW-PA204
C200HW-PA204C
C200HW-PA204R
C200HW-PA204S
C200HW-PA209R
C200HW-PD024
C200HW-PD025
Item
Power supply
voltage
100 to 240 VAC (wide range), 50/60 Hz *1
100 to 120 VAC/200 to 240 V, 50/60 Hz
24 VDC
Operating voltage
range
85 to 264 VAC
85 to 132 VAC/170 to 264 V
19.2 to 28.8 VDC
Power consumption
120 VA max.
Inrush current
120 VA max.
100 to 120 VAC input 15 A/8 ms max. (cold start at room temperature)
200 to 240 VAC input 30 A/8 ms max. (cold start at room temperature)
20 MΩ min. (at 500
VDC) between AC
Insulation resistance external and GR
terminals *2
Dielectric strength
100 VA max.
2,300 VAC 50/60 Hz
for 1 min between AC
external and GR
terminals *2
Leakage current:
10 mA max.
100 to 120 VAC input
20 A/8 ms max. (cold
start at room
temperature) 200 to
240 VAC input 30 A/8
ms max. (cold start
at room temperature)
180 VA max.
40 W max.
100 to 120 VAC:
30 A max.
200 to 240 VAC:
40 A max.
30 A max.
• 20 MΩ min. (at 500 VDC)
between all AC external
terminals and GR terminal
and between all alarm
output terminals.
• 20 MΩ min. (at 250 VDC)
between all alarm output
terminals and GR terminal.
20 MΩ min. (at 500 VDC) between all AC external and GR
terminals *2
• 2,300 VAC, 50/60 Hz for 1
minute between all AC
external terminals and GR
terminal and between all
alarm output terminals.
Leakage current: 10 mA
max.
• 1,000 VAC, 50/60 Hz for 1
minute between all alarm
output terminals and GR
terminal. Leakage current:
10 mA max.
2,300 VAC 50/60 Hz for 1 min between all AC external and GR
terminals *2
Leakage current: 10 mA max.
60 W max.
20 MΩ min. (at 500 VDC) between all DC
external and GR terminals *2
1,000 VAC 50/60 Hz for 1 min between all
DC external and GR terminals *2
Leakage current: 10 mA max.
1,000 VAC 50/60 Hz for 1 min between all DC external and GR terminals *2
Leakage current: 10 mA max.
Noise immunity
2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistance
Conforms to JIS 0040, 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes (Time coefficient: 8 minutes
x coefficient factor 10 = total time 80 min.)
(CPU Unit mounted to a DIN track: 2 to 55 Hz, 2.9 m/s2 in X, Y, and Z directions for 20 minutes)
Shock resistance
Conforms to JIS 0041, 147 m/s2 3 times each in X, Y, and Z directions
Ambient operating
temperature
0 to 55°C
Ambient operating
humidity
10% to 90% (with no
condensation)
Ambient operating
atmosphere
No corrosive gases
Ambient storage
temperature
-20 to 75°C (excluding battery)
Grounding
Less than 100 Ω
Enclosure
Mounted in a panel.
Weight
Each Rack: 6 kg max.
CPU Rack
dimensions (mm)
2 slots:
3 slots:
5 slots:
8 slots:
10 slots:
Standards
Conforms to UL, CSA, cULus, NK, Lloyds, and EC Directives.
*1.
*2.
*3.
*4.
10% to 90%
(with no condensation) *4
10% to 90% (with no condensation)
198.5 x 157 x 123 (W x H x D) *3
260 x 130 x 123 (W x H x D) *3
330 x 130 x 123 (W x H x D) *3
435 x 130 x 123 (W x H x D) *3
505 x 130 x 123 (W x H x D) *3
C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz.
Disconnect the Power Supply Unit’s LG terminal from the GR terminal when testing insulation and dielectric strength.
Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.
The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit. The depth is 111 mm for the C200HW-PA204C Power Supply Unit.
Maintain an ambient storage temperature of -25 to 30°C and relative humidity of 25% to 70% when storing the C200HW-PA204C for longer than 3 months to
keep the replacement notification function in optimum working condition.
Programmable Controllers
CS1G/H
11
Common Specifications for CPU Units
Item
Specifications
Control method
Stored program
I/O control method
Cyclic scan and immediate processing are both possible.
Programming
•Ladder diagrams
•SFC (sequential function charts)
•ST (structured text)
•Mnemonics
Instruction length
1 to 7 steps per instruction
Ladder instructions
Approx. 400 (3-digit function codes)
Execution time
Basic instructions
0.02 μs min.
Special instructions
0.04 μs min.
Number of tasks
288 (cyclic tasks: 32, interrupt tasks: 256)
Note 1:Cyclic tasks are executed each cycle and are controlled with TKON(820) and TKOF(821) instructions.
2:The following 4 types of interrupt tasks are supported. Power OFF interrupt tasks: 1 max. Scheduled interrupt tasks: 2 max. I/O interrupt tasks: 32 max. External interrupt tasks: 256 max.
Interrupt types
Scheduled Interrupts: Interrupts generated at a time scheduled by the CPU Unit’s built-in timer.
I/O Interrupts: Interrupts from Interrupt Input Units.
Power OFF Interrupts: Interrupts executed when the CPU Unit’s power is turned OFF.
External I/O Interrupts: Interrupts from the Special I/O Units, CS-series CPU Bus Units, or the Inner Board.
Function blocks *1
Languages in function block definitions: ladder programming, structured text
CIO (Core I/O)
Area
I/O Area
5,120: CIO 000000 to CIO 031915 (320 words from CIO 0000 to CIO 0319)
The setting of the first word can be changed from the default (CIO 0000) so that CIO 0000 to CIO 0999 can be used.
I/O bits are allocated to Basic I/O Units, such as CS-series Basic I/O Units, C200H Basic I/O Units, and C200H Group-2
High-density I/O Units.
Link Area
3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to CIO 1199)
Link bits are used for data links and are allocated to Units in Controller Link Systems and PLC Link Systems.
CPU Bus Unit Area
6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to CIO 1899)
CS-series CPU Bus Unit bits store the operating status of CS-series CPU Bus Units.
(25 words per Unit, 16 Units max.)
Special I/O Unit Area
15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000 to CIO 2959)
Special I/O Unit bits are allocated to CS-series Special I/O Units and C200H Special I/O Units. (See Note.)
(10 words per Unit, 96 Units max. The maximum total number of slots, however, is limited to 80 including expansion slots, so
the maximum number of Units is actually 80.
Note: A maximum of 16 C200H Special I/O Units can be mounted. Also, depending on the Units, the maximum may be 10.
Some I/O Units are classified as Special I/O Units.
Inner Board Area
1,600 (100 words): CIO 190000 to CIO 199915 (words CIO 1900 to CIO 1999)
Inner Board bits are allocated to Inner Boards. (100 I/O words max.)
SYSMAC BUS Area
800 (50 words): CIO 300000 to CIO 304915 (words CIO 3000 to CIO 3049)
SYSMAC BUS bits are allocated to Slave Racks connected to SYSMAC BUS Remote I/O Master Units. (10 words per Rack,
5 Racks max.)
I/O Terminal Area
512 (32 words): CIO 310000 to CIO 313115 (words CIO 3100 to CIO 3131)
I/O Terminal bits are allocated to I/O Terminal Units (but not to Slave Racks) connected to SYSMAC BUS Remote I/O
Master Units. (1 word per Terminal, 32 Terminals max.)
C200H Special I/O Unit
Area
8,192 bits (512 words): W00000 to W51115 (W000 to W511)
C200H Special I/O Unit bits are allocated to C200H Special I/O Units, and accessed separately from I/O refreshing.
DeviceNet Area
1,600 (100 words): Outputs: CIO 005000 to CIO 009915 (words CIO 0050 to CIO 0099)
Inputs: CIO 035000 to CIO 039915 (words CIO 0350 to CIO 0399)
DeviceNet bits are allocated to Slaves according to DeviceNet remote I/O communications.
PLC Link Area
64 bits (4 words): CIO 024700 to CIO 025015 (words CIO 0247 to CIO 0250)
When a PLC Link Unit is used in a PLC Link, use these bits to monitor PLC Link errors and the operating status of other
CPU Units in the PLC Link.
The CIO
Area can be
used as work
bits if the bits
are not used
as shown
here.
Internal I/O Area
4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)
37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to CIO 6143)
These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.)
Work Area
8,192 bits (512 words): H00000 to H51115 (H000 to H511)
These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.)
When using work bits in programming, use the bits in the Work Area first before using bits from other areas.
Holding Area
8,192 bits (512 words): H00000 to H51115 (H000 to H511)
Holding bits are used to control the execution of the program, and maintain their ON/OFF status when the PLC is turned OFF or the
operating mode is changed.
Note: The Function Block Holding Area words are allocated from H512 to H1535. These words can be used only for the function block
instance area (internally allocated variable area).
Auxiliary Area
Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)
Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)
Auxiliary bits are allocated specific functions.
Temporary Area
16 bits (TR0 to TR15)
Temporary bits are used to temporarily store the ON/OFF execution conditions at program branches.
Timer Area
4,096: T0000 to T4095 (separate from counters)
Note: The time units for timer settings are 0.1 s, 0.01 s, and 0.001 s (depending on the timer instruction that is used).
Counter Area
C0000 to C4095 (separate from timers)
DM Area
32K words: D00000 to D32767
Internal Special I/O Unit DM Area: D20000 to D29599 (100 words x 96 Units)
Used to set parameters for Special I/O Units.
CPU Bus Unit DM Area:
D30000 to D31599 (100 words x 16 Units)
Used to set parameters for CPU Bus Units.
Inner Board DM Area:
D32000 to D32099
Used to set parameters for Inner Boards.
Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the DM Area maintain their status when
the PLC is turned OFF or the operating mode is changed.
12
Programmable Controllers
CS1G/H
Item
Specifications
EM Area
32K words per bank, 13 banks max.: E0_00000 to EC_32767 max. (Varies by CPU Unit model.)
Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the EM Area maintain their status when
the PLC is turned OFF or the operating mode is changed.
The EM Area is divided into banks, and the addresses can be set by either of the following methods.
Changing the current bank using the EMBC(281) instruction and setting addresses for the current bank. Setting bank numbers and
addresses directly.
EM data can be stored in files by specifying the number of the first bank.
Data Registers
DR0 to DR15: Store offset values for indirect addressing. One register is 16 bits (1 word).
Index Registers
IR0 to IR15: Store PLC memory addresses for indirect addressing. One register is 32 bits (2 words).
Task Flag Area
32 (TK0000 to TK0031): Task Flags are read-only flags that are ON when the corresponding cyclic task is executable and OFF when the
corresponding task is not executable or in standby status.
Trace Memory
4,000 words (The maximum amount of data that can be traced in a data trace is 500 samples for 31 bits and 6 words.
File Memory
Memory Cards: Compact flash memory cards can be used (MS-DOS format).
EM file memory: Part of the EM Area can be converted to file memory (MS-DOS format).
Parallel Processing
Modes
Program execution and peripheral servicing can be performed simultaneously.
Battery-free operation
The user program and the system’s parameters are backed up automatically in flash memory, which is standard equipment.
Constant cycle time
Possible (1 to 32,000 ms) (Unit: 1 ms)
Cycle time monitoring
Possible (Unit stops operating if the cycle is too long): 10 to 40,000 ms (Unit: 10 ms)
I/O refreshing
Cyclic refreshing, immediate refreshing, refreshing with I/O REFRESH instruction
I/O memory holding
when changing
operating modes
Possible (Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.)
Load OFF
All outputs on Output Units can be turned OFF.
Input response time
setting
Time constants can be set for inputs from Basic I/O Units.
The time constant can be increased to reduce the influence of noise and chattering or it can be decreased to detect shorter pulses on the
inputs (CS1 Basic I/O Units only).
Startup mode setting
Supported.
Automatically reading programs (autoboot) from the Memory Card when the power is turned ON.
Memory Card
functions
Format in which data is stored in Memory Card
User program: Program file format
PLC Setup and other parameters: Data file format (binary format)
I/O memory: Data file format (binary format), text format, or CSV format
Functions for which Memory Card read/write is
supported
User program instructions, Programming Devices (including Programming Consoles),
Host Link computers
Filing
Memory Card data and the EM (Extended Data Memory) Area can be handled as files.
Debugging
Control set/reset, differential monitoring, data tracing (scheduled, each cycle, or when instruction is executed), storing location generating
error when a program error occurs
Online editing
User programs can be overwritten in program-block units when the CPU Unit is in MONITOR or PROGRAM mode.
(This function is not available for block programming areas.)
Program protection
Overwrite protection: Set using DIP switch.
Copy protection: Password set using Programming Device.
Error check
User-defined errors (i.e., user can define fatal errors and non-fatal errors)
The FPD(269) instruction can be used to check the execution time and logic of each programming block.
Error log
Up to 20 errors are stored in the error log. Information includes the error code, error details, and the time the error occurred.
Functions
Serial
communications
Built-in peripheral port: Programming Device (including Programming Console) connections, Host Links, NT Links
Built-in RS-232C port: Programming Device (excluding Programming Console) connections, Host Links, no-protocol communications, NT
Links, and Serial Gateway *3
Serial communications board (order separately): protocol macros, Host Links, no-protocol communications *3, NT Links, Serial Gateway
*3, and Modbus-RTU Slave *5
Clock
Provided on all models.
Note: Used to store the time when power is turned ON and when errors occur.
Power OFF detection
time
10 to 25 ms (not fixed)
Power OFF detection
delay time
0 to 10 ms (user-defined, default: 0 ms)
Memory retention
during power
interruptions
Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of the counter Completion Flags and present
values.
Note: If the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to maintain the IOM Hold Bit status when power to
the PLC is turned ON, the contents of the CIO Area, the Work Area, part of the Auxiliary Area, timer Completion Flags and PVs, Index
Registers, and the Data Registers will be saved.
Sending commands to
a Host Link computer
FINS commands can be sent to a computer connected via the Host Link System by executing Network Communications Instructions from
the PLC.
Remote programming
and monitoring
Host Link communications can be used for remote programming and remote monitoring through a Controller Link System or Ethernet
network.
8-level
communications *2
Remote programming and monitoring across up to eight network layers (Controller Link or Ethernet) by using Host Link. (They are possible
between different types of networks.)
Storing comments in
CPU Unit
I/O comments can be stored in the CPU Unit in Memory Cards *1 or EM file memory.
Program check
Program checks are performed at the beginning of operation for items such as no END instruction and instruction errors.
Programming Devices (except for the Programming Consoles) can also be used to check programs.
RUN output: The internal contacts will be ON (closed) while the CPU Unit is operating in RUN mode or MONITOR mode.
Control output signals These terminals are provided only on C200HW-PA204R, C200HW-PA209R, and CS1D-PA207R Power Supply Units.
*1.
*2.
*3.
*4.
*5.
Battery service life
The battery life is 5 years at an ambient temperature of 25°C, although the lifetime can be as short as 1.1 years under adverse temperature
and power conditions. (Battery Set: CS1W-BAT01) *3 *4
Self-diagnostics
CPU errors (watchdog timer), I/O verification errors, I/O bus errors, memory errors, and battery errors.
Other functions
Words in the Auxiliary Area store the number of power interruptions, time of the last power interruption, and total power ON time.
CPU Units with unit version 3.0 or later only.
CPU Units with unit version 2.0 or later only. (Communications across three network layers is supported for Pre-Ver. 2.0 CPU Units.)
CPU Units with unit version 3.0 or later only or Serial Communications Board/Unit with unit version 1.2 or later only.
Use a replacement battery that was manufactured within the last two years.
Serial Communications Board/Unit with unit version 1.3 or later only.
Programmable Controllers
CS1G/H
13
■ Functions Added by Unit Version
The following functions have been added for the unit versions of CS1G/H CPU Units.
OK: Supported, ---: Not supported
Model
Function
Unit version
CS1@-CPU@@H
No unit version
Unit version 2.0
Unit version 3.0
Unit version 4.0
Downloading and Uploading Individual Tasks
---
OK
OK
OK
Improved Read Protection Using Passwords
---
OK
OK
OK
Write Protection from FINS Commands Sent to CPU Units via
Networks
---
OK
OK
OK
Online Network Connections without I/O Tables
---
OK
OK
OK
Communications through a Maximum of 8 Network Levels
---
OK
OK
OK
OK
(from lot number 030201)
OK
OK
OK
OK
(for up to 8 group)
OK
(for up to 64 group)
OK
(for up to 64 group)
OK
Automatic Transfers at Power ON without a Parameter File (.STD)
---
OK
OK
OK
Automatic Detection of I/O Allocation Method for Automatic
Transfer at Power ON
---
---
---
OK
Operation Start/End Times
Connecting Online to PLCs via NS-series PTs
Setting First Slot Words
Support of
new
instructions
---
OK
OK
OK
MILH, MILR, MILC
---
OK
OK
OK
= DT, DT, DT, > = DT
---
OK
OK
OK
BCMP2
---
OK
OK
OK
GRY
OK
(from lot number 030201)
OK
OK
OK
TPO
---
OK
OK
OK
DSW, TKY, HKY, MTR, 7SEG
---
OK
OK
OK
EXPLT, EGATR, ESATR, ECHRD, ECHWR
---
OK
OK
OK
OK
(from lot number 030418)
OK
OK
OK
IORD/IOWR reading/writing to CPU Bus Units
---
---
---
OK
Function blocks (CX-Programmer Ver.5.0 or later)
PRV2
---
---
OK
OK
Serial Gateway (converting FINS commands to CompoWay/
F commands at the built-in serial port)
---
---
OK
OK
Comment memory (in internal flash memory)
---
---
OK
OK
Expanded simple backup data
---
---
OK
OK
TXDU(256), RXDU(255) (support no-protocol communications with
Serial Communications Units with unit version 1.2 or later)
---
---
OK
OK
Model conversion instructions: XFERC(565), DISTC(566),
COLLC(567), MOVBC(568), BCNTC(621)
---
---
OK
OK
Special function block instructions: GETID(286)
---
---
OK
OK
Additional
instruction
functions
TXD(236), RXD(235) (support no-protocol
communications with Serial Communications Units
with unit version 1.2 or later)
---
---
OK
OK
Conversion instructions from numbers to ASCII
and ASCII to numbers
---
---
---
OK
Flowchart conversion instructions (one type of
block programming instructions) to convert
flowchart programs from C-series Flowchart PLCs
to ladder programs for CS/CJ-series PLCs
---
---
---
OK
Online editing of function blocks
---
---
---
OK
Support for I/O variables (including array variables
for I/O variables)
---
---
---
OK
Support for STRING data type and processing
functions for ST language.
---
---
---
OK
Use of new
special
instructions
Function
block (FB)
functional
upgrades
● Unit Versions
Unit versions have been introduced to control differences in
functions featured by CPU Units that are the result of version
upgrades.
The unit version is marked on the nameplates of products subject
to version control, as shown in the diagram.
Unit
Unit version
■ Unit Versions and Programming Devices
Applicable PLCs
CS1G/H-series
14
Name
CS1H-CPU67H/66H/65H/64H/63H
CS1G-CPU45H/44H/43H/42H
Programmable Controllers
CX-Programmer
No unit version
Version 2.1 or later
Unit version 2.0
Version 4.0 or later
Unit version 3.0
Version 5.0 or later
Unit version 4.0
Version 7.0 or later
CS1G/H
Current Consumption for Power Supply Units
■ Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power
requirements for each Rack.
Condition 1: Current Requirements
There are three voltage groups for internal power consumption: 5 V, 26 V, and 24 V.
• Current consumption at 5 V (internal logic power supply)
• Current consumption at 26 V (relay driving power supply)
• Current consumption at 24 V (power supply output terminals) (C200HW-PA204S only)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system
so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current
supplied for the voltage groups shown in the following tables.
● CPU Racks and Expansion Racks
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are
shown below.
Note 1:For CPU Racks, include the CPU Backplane and CPU Unit current and power consumption in the calculations.
2: For Expansion Racks, include the Expansion Backplanes current and power consumption in the calculations.
Max. current supplied
(A) 5 V
(B) 26 V
(C) 24 V
(D) Max. total
power supplied
C200HW-PA204C
4.6 A
0.6 A
---
30 W
C200HW-PA204
4.6 A
0.6 A
---
30 W
C200HW-PA204S
4.6 A
0.6 A
0.8 A
30 W
C200HW-PA204R
4.6 A
0.6 A
---
30 W
45 W
Power Supply Units
C200HW-PA209R
9A
1.3 A
---
C200HW-PD024
4.6 A
0.6 A
---
30 W
C200HW-PD025
5.3 A
1.3 A
---
40 W
7A
1.3 A
---
35 W
4.3 A
0.56 A
---
28 W
CS1D-PA207R
CS1D-PD024
Conditions 1 and 2 below must be satisfied.
Condition 1: Maximum Current
(1) Total Unit current consumption at 5 V ≤ (A) value
(2) Total Unit current consumption at 26 V ≤ (B) value
(3) Current consumption for service power supply at 24 V ≤ (C) value (Only when using the service power supply from the
C200HW-PA204S.)
Condition 2: Maximum Power
(1) x 5 V + (2) x 26 V + (3) x 24 V ≤ (D) value
■ Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CS-series CPU Rack Using a CS1W-PA204S Power Supply Unit
Type
Model
Quantity
CPU Backplanes
(8 slots)
CS1W-BC083
CPU Unit
Input Unit
Voltage group
5V
26 V
24 V
1
0.11 A
---
---
CS1H-CPU67H
1
0.82 A
---
---
CS1W-ID211
2
0.10 A
---
-----
CS1W-ID291
2
0.20 A
---
Output Unit
CS1W-OC201
2
0.10 A
0.048 A
---
Special I/O Unit
CS1W-NC213
1
0.25 A
---
---
CPU Bus Unit
CS1W-CLK23
1
0.33 A
---
---
0.3 A used
---
---
0.3 A
0.11 A + 0.82 A + 0.10 A x 2 +
0.20 A x 2 + 0.10 A x 2 +
0.25 A + 0.33 A
0.048 A x 2
0.3 A
Service power supply
Current consumption
Power consumption
Total
Result
2.31 A (≤ 4.6 A)
0.096 A (≤ 0.6 A)
0.3 A (≤ 0.8 A)
Total
2.31 A x 5 V=11.55 W
0.096 A x 26 V=2.496 W
0.3 A x 24 V=7.2 W
Result
11.55 + 2.496 + 7.2 = 21.246W (≤ 30W)
Note: For details on Unit current consumption, refer to Ordering Information.
Programmable Controllers
CS1G/H
15
■ Using the CX-Programer to Display Current Consumption and Width
CPU Rack and Expansion Rack current consumption and width can be displayed by selecting Current Consumption and Width from the
Options Menu in the CS1 Table Window. If the capacity of the Power Supply Unit is exceeded, it will be displayed in red characters.
Example:
Current consumption
at 5 V
Power Supply
Current
Total current Long-distance
Unit model
expansion
consumption consumption
at 26 V/24 V
16
Programmable Controllers
CS1G/H
Width
Ordering Information
Basic Configuration Units ................................................................................18
Programming Devices...................................................................................... 22
Accessories and Maintenance Parts ...............................................................25
DIN Track Mounting Accessories .....................................................................25
Basic I/O Units .................................................................................................26
Special I/O Units, CPU Bus Units, and Inner Boards ......................................32
Replacing C200H I/O Units ..............................................................................49
Ordering Information
● Applicable Standards
Refer to the OMRON website (www.ia.omron.com) or
ask your OMRON representative for the most recent
applicable standards for each model.
● EU Directives
The EU Directives applicable to PLCs include the EMC
Directives and the Low Voltage Directive. OMRON
complies with these directives as described below
manufacturing installations.
● EMC Directives
Applicable Standards EMI: EN61000-6-4
EN61131-2
EMS: EN61000-6-2
EN61131-2
OMRON PLCs conform to the related EMC standards
so that the devices and machines into which they are
built can more easily conform to EMC standards. The
actual PLCs have been checked for conformity to
EMC standards. Whether these standards are
satisfied for the actual system, however, must be
checked by the customer.
EMC-related performance will vary depending on the
configuration, wiring, and other conditions of the
equipment or control panel in which the PLC is
installed.
The customer must, therefore, perform final checks to
confirm that the overall machine or device conforms
to EMC standards.
● Low Voltage Directive
Applicable Standard: EN61131-2
Devices that operate at voltages from 50 to 1,000
VAC or 75 to 150 VDC must satisfy the appropriate
safety requirements. With PLCs, this applies to
Power Supply Units and I/O Units that operate in
these voltage ranges.
These Units have been designed to conform to
EN61131-2, which is the applicable standard for
PLCs.
17
Ordering Information
Basic Configuration Units
CPU Rack
■ CS1 CPU Units
Mountable Racks
Specifications
CS1 CPU Rack
Product
name
Number of Program
I/O points capacity
CS1 CPU
Units
Data memory
capacity
LD
instruction
execution time
Online
Unit
replacement
Duplex
Communications
Units
Duplex
Power
Supply
Units
CS-series
CPU
Backplane
CS1W-BC@@2
CS1D CPU
Rack
Current
consumption
(A)
CS1D CPU
CS/C200HBackplane
5V
26 V
series CPU
CS1D-BC082S
system system
Backplane
or
CS1W-BC@@3
CS1D-BC052
Model
448K words
5,120
(DM: 32K words,
(Expansion 250K steps
EM: 32K words ×
Racks: 7)
13 banks)
*
0.82
---
CS1H-CPU67H
256K words
5,120
(DM: 32K words,
(Expansion 120K steps
EM: 32K words ×
Racks: 7)
7 banks)
*
0.82
---
CS1H-CPU66H
*
0.82
---
CS1H-CPU65H
*
0.82
---
CS1H-CPU64H
*
0.82
---
CS1H-CPU63H
5,120
(Expansion 60K steps
Racks: 7)
128K words
(DM: 32K words,
EM: 32K words ×
3 banks)
5,120
(Expansion 30K steps
Racks: 7)
64K words
(DM: 32K words,
EM: 32K words ×
1 bank)
5,120
(Expansion 20K steps
Racks: 7)
64K words
(DM: 32K words,
EM: 32K words ×
1 bank)
5,120
(Expansion 60K steps
Racks: 7)
128K words
(DM: 32K words,
EM: 32K words ×
3 banks)
*
0.78
---
CS1G-CPU45H
1,280
(Expansion 30K steps
Racks: 3)
64K words
(DM: 32K words,
EM: 32K words ×
1 bank)
*
0.78
---
CS1G-CPU44H
960
(Expansion 20K steps
Racks: 2)
64K words
(DM: 32K words,
EM: 32K words ×
1 bank)
*
0.78
---
CS1G-CPU43H
960
(Expansion 10K steps
Racks: 2)
64K words
(DM: 32K words,
EM: 32K words ×
1 bank)
*
0.78
---
CS1G-CPU42H
0.02 µs
No
No
No
Yes
0.04 µs
No
No
Yes
No
No
* These values include the current consumption of a connected Programming Console. NT-AL001 Link Adapters consume an additional 0.15 A each when used.
18
Programmable Controllers
CS1G/H
■ Power Supply Units
One Power Supply Unit is required for each Rack.
Output capacity
Product
name
AC Power
Supply
Unit
Power
supply
voltage
100 to 240
VAC (wide
range)
AC Power 100 to 240
Supply
VAC
Unit
(wide
range) *
100 to 120
VAC or 200
to 240 VAC
DC Power
Supply
Unit
5-VDC Model
26-VDC
Standards
output
output
capacity
capacity
Options
24-VDC
Total
0.8 A
power con- service
sumption power
supply
RUN
output
Mountable Racks
Maintenance
forecast
monitor
C200HX/
CS1 LongCS1
CS1D
CPU HG/HE
distance
ExpanCPU
Rack Expansion
Expansion
sion Rack
Rack
I/O Rack
Rack
CS1D
Expansion
Rack
SYSMAC
BUS
Slave
Rack
Model
Yes
C200HW-PA204C
No
C200HW-PA204
No
C200HW-PA204R
4.6 A
0.625 A
30 W
No
No
4.6 A
0.625 A
30 W
No
Yes
0.625 A
(with
0.8 A,
24 VDC
service
power
supply)
30 W
Yes
No
No
9A
1.3 A
45 W
No
Yes
No
C200HW-PA209R
4.6 A
0.625 A
30 W
No
No
No
C200HW-PD024
5.3 A
1.3 A
40 W
No
No
No
C200HW-PD025
4.6 A
Yes
No
Yes
C200HW-PA204S
24 VDC
* C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz.
■ CS1 CPU Backplane
Mountable configuration units
Product name
Specifications
Applicable
CPU
CS-series
Unit
Basic I/O
Unit
Basic I/O Units
Special I/O Units
C200H
Group-2
CS-series
Special I/O
Highdensity I/O Unit
Unit
C200Hseries
Basic
I/O Unit
Current
consumption
(A)
CPU Bus
Units
C200HCS-series
series
CPU Bus
Special I/O
Unit
Unit
Model
5V
26 V
system system
2 slots
(Note:
Expansion
Racks cannot
be connected.)
For CS-series
Unit only
Note: C200Hseries Units 3 slots
cannot be
5 slots
mounted.
8 slots
10 slots
CS1 CPU Backplane
For both CS/
C200H-series
Units
2 slots
(Note:
Expansion
Racks cannot
be connected.)
Yes
No
Yes
No
Yes
CS1
CPU
Unit
Yes
3 slots
0.11
---
CS1W-BC022
0.11
---
CS1W-BC032
0.11
---
CS1W-BC052
0.11
---
CS1W-BC082
0.11
---
CS1W-BC102
0.11
---
CS1W-BC023
0.11
---
CS1W-BC033
5 slots
0.11
---
CS1W-BC053
8 slots
0.11
---
CS1W-BC083
10 slots
0.11
---
CS1W-BC103
2 slots (CS1W-BC022/023):
3 slots (CS1W-BC032/033):
Dimensions (mm) 5 slots (CS1W-BC052/053):
8 slots (CS1W-BC082/083):
10 slots (CS1W-BC102/103):
198.5 x 157 (W x H)
260 x 132 (W x H)
330 x 132 (W x H)
435 x 132 (W x H)
505 x 132 (W x H)
Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2).
2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2).
Programmable Controllers
CS1G/H
19
Expansion Racks
Select the Backplane, Power Supply Unit, and Expansion Cable. If the expansion length is more than 12 m, an I/O Interface Unit is also
required.
■ Expansion Backplanes
● Normal Expansion (Not Long-distance Expansion)
Mountable configuration units
Basic I/O Units
Product name
Specifications
CS-series
Basic I/O
Unit
3 slots
For CS-series Unit
only
5 slots
Note: C200H-series
Units cannot be 8 slots
mounted.
10 slots
CS1 Expansion
Backplanes
For both CS/C200Hseries Units
Dimensions (mm)
Dimensions (mm)
C200H
Group-2
Highdensity I/O
Unit
CS-series
Special I/O
Unit
C200Hseries
Special I/O
Unit
Current
consumption
(A)
Model
CS-series
CPU Bus
Unit
5V
26 V
system system
0.23
---
CS1W-BI032
0.23
---
CS1W-BI052
0.23
---
CS1W-BI082
0.23
---
CS1W-BI102
3 slots
0.23
---
CS1W-BI033
5 slots
0.23
---
CS1W-BI053
8 slots
0.23
---
CS1W-BI083
10 slots
0.23
---
CS1W-BI103
0.15
---
C200HW-BI031
0.15
---
C200HW-BI051
0.15
---
C200HW-BI081-V1
0.15
---
C200HW-BI101-V1
No
No
No
Yes
Yes
Yes
3 slots (CS1W-BCI032/033):
5 slots (CS1W-BI052/053):
8 slots (CS1W-BI082/083):
10 slots (CS1W-BI102/103):
3 slots
For C200H-series
Unit only
5 slots
Note: CS-series Units
8 slots
cannot be
mounted.
10 slots
C200HX/HG/HE
Expansion
I/O Backplane
C200Hseries
Basic I/O
Unit
CPU Bus
Units
Special I/O Units
No
Yes
Yes
260 x 132 (W x H)
330 x 132 (W x H)
435 x 132 (W x H)
505 x 132 (W x H)
Yes
3 slots (C200HW-BI031):
5 slots (C200HW-BI051):
8 slots (C200HW-BI081-V1):
10 slots (C200HW-BI101-V1):
Yes
Yes
No
Yes
No
189 x 132 (W x H)
259 x 132 (W x H)
364 x 132 (W x H)
434 x 132 (W x H)
● Long-distance Expansion
Mountable configuration units
Basic I/O Units
Product name
CS1 Expansion
Backplanes
Specifications
3 slots
For CS-series
Unit only
5 slots
Note: C200H-series
Units cannot be 8 slots
mounted.
10 slots
For both CS/C200Hseries Units
CPU Unit
mounted
to CPU
C200HBackplane CS-series series
Basic I/O
Basic I/O
Unit
Unit
C200H
Group-2
Highdensity
I/O Unit
Special I/O Units
C200HCS-series
series
Special
Special
I/O Unit
I/O Unit
CPU Bus
Units
Current
consumption
(A)
Model
CS-series
5V
26 V
CPU Bus
system system
Unit
0.23
---
CS1W-BI032
0.23
---
CS1W-BI052
0.23
---
CS1W-BI082
0.23
---
CS1W-BI102
3 slots
0.23
---
CS1W-BI033
5 slots
0.23
---
CS1W-BI053
8 slots
0.23
---
CS1W-BI083
10 slots
0.23
---
CS1W-BI103
CS1 CPU
Unit
Yes
No
Yes
No
Yes *
* CS-series CPU Bus Units can be mounted in a Long-distance Expansion Rack, but the I/O refreshing time is longer than it is when the CPU Bus Unit is mounted in
the CPU Rack.
Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2).
2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2).
20
Programmable Controllers
CS1G/H
■ I/O Control Unit (Required for long-distance expansion)
The CS1W-IC102 I/O Control Unit is mounted to a CPU Backplane or CS1 Expansion Backplane when expanding more than 12 m. A
CV500-CN@@2 Long-distance Expansion Connecting Cable is used to connect the I/O Control Unit to a CS1W-II102 I/O Interface Unit.
Current
consumption
(A)
Mountable backplanes
Product name
Specifications
CPU
CS1 Expansion
backplane Backplanes
I/O Control Unit
Required to expand more than 12 m.
(Two CV500-TER01 Terminators are included.)
Connecting cable: Connecting Cable for Long-distance
Expansion CV500-CN@@2
Connecting unit: Interface Unit CS1W-II102
Yes
5V
system
26 V
system
0.92
---
Yes
Model
CS1W-IC102
■ I/O Interface Unit (Required for long-distance expansion)
The CS1W-II102 I/O Interface Unit is mounted to a CS1 Expansion Backplane and connected to a CV500-CN@@2 Long-distance
Expansion Connecting Cable when expanding more than 12 m.
Product name
Current
consumption
(A)
Specifications
5V
system
24 V
system
0.23
---
Model
I/O Interface Unit
Required to expand more than 12 m.
Mountable backplane: CS1 Expansion Backplanes
Connecting cable: Connecting Cable for Long-distance Expansion
CV500-CN@@2
CS1W-II102
■ Connecting Cables for Expansion Backplanes
Product name
Specifications
Model
CS1 I/O Connecting
Cables
Connects a CPU Backplane or CS1 Expansion Backplane to a
CS1 Expansion Backplane.
CS1 to C200H I/O
Connecting Cables
Connects a CPU Backplane or CS1 Expansion Backplane to a
C200HX/HG/HE Expansion I/O Backplane.
C200H I/O Connecting
Cables
Connects a C200HX/HG/HE Expansion I/O Backplane to a
C200HX/HG/HE Expansion I/O Backplane.
Cable length: 0.3 m
CS1W-CN313
Cable length: 0.7 m
CS1W-CN713
Cable length: 2 m
CS1W-CN223
Cable length: 3 m
CS1W-CN323
Cable length: 5 m
CS1W-CN523
Cable length: 10 m
CS1W-CN133
Cable length: 12 m
CS1W-CN133-B2
Cable length: 0.3 m
CS1W-CN311
Cable length: 0.7 m
CS1W-CN711
Cable length: 2 m
CS1W-CN221
Cable length: 3 m
CS1W-CN321
Cable length: 5 m
CS1W-CN521
Cable length: 10 m
CS1W-CN131
Cable length: 12 m
CS1W-CN131-B2
Cable length: 0.3 m
C200H-CN311
Cable length: 0.7 m
C200H-CN711
Cable length: 2 m
C200H-CN221
Cable length: 5 m
C200H-CN521
Cable length: 10 m
C200H-CN131
Cable length: 0.3 m
CV500-CN312
Cable length: 0.6 m
CV500-CN612
Cable length: 1 m
CV500-CN122
Cable length: 2 m
CV500-CN222
Cable length: 3 m
CV500-CN322
Cable length: 5 m
CV500-CN522
Cable length: 10 m
CV500-CN132
Cable length: 20 m
CV500-CN232
Cable length: 30 m
CV500-CN332
Cable length: 40 m
CV500-CN432
Cable length: 50 m
CV500-CN532
■ Connecting Cables for Long-distance Expansion
Product name
Specifications
Model
Connecting Cables for
Long-distance
Expansion
Connects a Long-distance I/O Control Unit to an I/O Interface Unit.
Reading the production number
@@@@
Year (e.g., 1997=7)
Month (1 to 9, X (10), Y (11), Z (12))
Day (01 to 31)
Programmable Controllers
CS1G/H
21
Programming Devices
■ Support Software
Product name
Specifications
Number of Model
Standards licenses
--- (Media only) *
FA Integrated Tool
Package
CX-One Ver.4.@
DVD
CXONE-AL00D-V4
DVD
CXONE-AL01D-V4
DVD
CXONE-AL03D-V4
DVD
CXONE-AL10D-V4
30 licenses
DVD
CXONE-AL30D-V4
50 licenses
DVD
CXONE-AL50D-V4
The CX-One is a comprehensive software package that integrates
1 license
Support Software for OMRON PLCs and components.
CX-One runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista 3 licenses
(32-bit/64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8
(32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version) / Windows
10 licenses
10 (32-bit/64-bit version)
CX-One Version 4.@ includes CX-Programmer and CX-Simulator.
For details, refer to the CX-One catalog (Cat. No. R134).
Model
Media
Note 1: Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details.
2: Before ordering the software on a DVD, be sure that your computer and drive are compatible with the DVD format.
* The CXONE-AL00D-V4 contains only the DVD installation media for users who have purchased the CX-One Version 4. @ and does not include the license number.
Enter the license number of the CX-One Version 4. @ when installing.
(The license number of the CX-One Version 3. @ or lower cannot be used for installation.)
● Support Software in CX-One Ver.4.@
The following tables lists the Support Software that can be installed from CX-One.
Support Software in CX-One
Outline
CX-Programmer
Application software to create and debug programs for CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series CPU Units, and to
create and monitor data for CS/CJ-series Position Control Units.
CX-Integrator
Application software to build and set up FA networks, such as Controller Link, DeviceNet, CompoNet, CompoWay/F, and Ethernet
networks. The Routing Table Component and Data Link Component can be started from here. DeviceNet Configuration
functionality is also included.
Switch Box Utility
Utility software that helps you to debug PLCs. It helps you to monitor the I/O status and to monitor/change present values within
the PLC you specify.
CX-Protocol
Application software to create protocols (communications sequences) between CS/CJ/CP/NSJ-series or C200HX/HG/HE Serial
Communications Boards/Units and general-purpose external devices.
CX-Simulator
Application software to simulate CS/CJ/CP/NSJ-series CPU Unit operation on the computer to debug PLC programs without a
CPU Unit.
CX-Position
Application software to create and monitor data for CS/CJ-series Position Control Units. (except for High-speed type)
CX-Motion-NCF
Application software to creat and monitor data for CS/CJ-series Position Control Units with MECHATROLINK-II * interface
(NC@71).
CX-Motion-MCH
Application software to create data, and monitor program, and monitor data for CS/CJ-series Motion Control Units with
MECHATROLINK-II * interface (MCH71).
CX-Motion
Application software to create data for CS/CJ-series, C200HX/HG/HE, and CVM1/CV-series Motion Control Units, and to create
and monitor motion control programs.
CX-Drive
Application software to set and control data for Inverters and Servos.
CX-Process Tool
Application software to create and debug function block programs for CS/CJ-series Loop Controllers (Loop Control Units/Boards,
Process Control CPU Units, and Loop Control CPU Units).
Faceplate
Auto-Builder for NS
Application software that automatically outputs screen data as project files for NS-series PTs from tag information in function
block programs created with the CX-Process Tool.
CX-Designer
Application software to create screen data for NS-series PTs.
NV-Designer
Applications software to create screen data for NV-series small PTs.
CX-Configurator FDT
Applications software to setting various units by installing its DTM module.
CX-Thermo
Application software to set and control parameters in components such as Temperature Control Units.
CX-FLnet
Application software for system setting and monitoring of CS/CJ-series FL-net Units.
Network Configurator
Application software for setting the tag datalink at the built-in EtherNet/IP port.
CX-Server
Middleware necessary for CX-One applications to communicate with OMRON components, such, such as PLCs, Display
Devices, and Temperature Control Units.
Communications Middleware
Middleware necessary to communicate with CP1L CPU Units with built-in Ethernet port.
PLC Tools
(Installed automatically.)
A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following:
I/O tables, PLC memory, PLC Setup, Data Tracing/Time Chart Monitoring, PLC Error Logs, File Memory, PLC clock, Routing
Tables, and Data Link Tables.
Note: If the complete CX-One package is installed, approximately 4.0 GB of Hard disk space will be required.
22
Programmable Controllers
CS1G/H
■ Connecting Cables for CX-One Components (e.g. CX-Programmer)
Specifications
Product name
Applicable
computers
Cable
length
Connection configuration
IBM PC/AT or compatible computer + CS1W-CN226/626 +
Peripheral port of CPU Unit
Can be used for
both peripheral
bus and host link.
RS-232C
Cables
between
Programming
Device
(computer)
and
peripheral
port
Peripheral Port
Connecting Cable
CS1W-CN226/626
Computer
(9-pin RS-232C)
IBM PC/AT or
compatible
computer
(D-Sub 9-pin)
The following configuration can be used when using an
RS-232C cable to connect to an IBM PC/AT or compatible
computer.
IBM PC/AT or compatible computer + XW2Z-200S-CV/V or
XW2Z-500S-CV/V + Peripheral port of CPU Unit.
RS-232C Cable
XW2Z-200S-CV/V
XW2Z-500S-CV/V
0.1 m
2m
Serial Communications Board's
RS-232C ports
Computer
(9-pin RS-232C)
5m
RS-232C Cable
XW2Z-200S-CV/V (2 m)
XW2Z-500S-CV/V (5 m)
Active CPU Unit
Standby CPU Unit
RUN
ERR/ALM
DPL01
L
INH BKUP
PRPHL COMM
SYSMAC
CS1D-CPU67H
R
ERR/ALM
INH BKUP
PRPHL COMM
LEFT CPU
SYSMAC
CS1D-CPU67H
USE
PROGRAMMABLE CONTROLLER
NO USE
USE
BUSY
MCPWR
BUSY
NO USE
OPEN
DPL SW
ON OFF
SPL DPL
ACT. ACT.
LEFT RIGHT
ON
PERIPHERAL
INIT.
+5V
SW
PRPHL
COMM
A39512
RSV
ON
PORT
PORT
DUPLEX
RS-422A/485
XW2Z-500S-CV
Can be used for
host link only.
Cannot be used
for peripheral bus.
RIGHT CPU
MCPWR
OPEN
NT-AL001
XW2Z-200S-CV
RS-422A/485
XW2Z-200S-V
2m
RUN
DPL STATUS
ACTIVE
CPU STATUS
ACTIVE
CPU STATUS
PROGRAMMABLE CONTROLLER
PERIPHERAL
RS-232C
Can be used for
both peripheral
bus and host link,
and is equipped
with an anti-static
connector.
CPU Unit's built-in
RS-232C port
Note: We recommend the following configuration if the
CX-Programmer is always connected and you want to avoid
switching to the other CPU Unit when an error occurs.
Terminator ON
+5 V must be supplied to the
NT-AL001 at computer side.
Use when
connecting to the
peripheral port
CS1W-CN118
with a XW2Z200S-CV/V or
XW2Z-500S-CV/V
RS-232C Cable.
CS1W-CN118
IBM PC/AT or compatible computer + XW2Z-200S-CV/V or
XW2Z-500S-CV/V + RS-232C port of CPU Unit or Serial
Communications Board/Unit
IBM PC/AT or
compatible
computer
(D-Sub 9-pin)
CS1W-CN626
6m
Peripheral port
Connecting Cables
between Programming
Device (computer) and
RS-232C port
CS1W-CN226
2m
Peripheral port
Model
Remarks
RS-422A Adapter
CJ1W-CIF11
or NT-AL001
XW2Z-500S-V
5m
CX-Programmer
IBM PC/AT or compatible computer +
CS1W-CIF31 + CS1W-CN226/626 + Peripheral port
of CPU Unit
USB-Serial Conversion Cable
CS1W-CIF31
Computer
USB port
USB-Serial Conversion
Cable (PC driver CD-ROM
IBM PC/AT or
included)
compatible
computer
(D-Sub 9-pin)
Conforms to USB 2.0
Specifications.
Serial Connecting Cable
CS1W-CN226/626
XW2Z-200S-CV/500S-CV
XW2Z-200S-V/500S-V
CQM1-CIF02
Peripheral port or
RS-232C port
IBM PC/AT or compatible computer +
CS1W-CIF31 + XW2Z-200S-CV/500S-CV +
CS1W-CN118 + Peripheral port of CPU Unit
IBM PC/AT or compatible computer +
CS1W-CIF31 + XW2Z-200S-V/500S-V +
CS1W-CN118 + Peripheral port of CPU Unit
IBM PC/AT or compatible computer +
CS1W-CIF31 + XW2Z-200S-CV/500S-CV +
CS1W-CN118 + RS-232C port of CPU Unit or
Serial Communications Board/Unit
IBM PC/AT or compatible computer +
CS1W-CIF31 + XW2Z-200S-V/500S-V + RS-232C
port of CPU Unit or Serial Communications Board/
Unit
The USB
Serial
Conversion
Cable
connects to
the serial
connecting
cable,
0.5 m
which
connects to
the PLC’s
peripheral
port or
RS-232C
port.
Can be used for
both peripheral
bus and host link.
Can be used for
both peripheral
bus and host link.
CS1W-CIF31
Can be used for
host link only.
Cannot be used
for peripheral bus.
Can be used for
both peripheral
bus and host link.
Can be used for
host link only.
Cannot be used
for peripheral bus.
Programmable Controllers
CS1G/H
23
Note: Either of the serial communications modes listed in the following table can be used to connect CX-One Support Software (e.g., the CX-Programmer) to a
CS1-series PLC.
Serial communications mode
Features
Peripheral bus
This mode can provide high-speed communications, so this mode is normally used to connect when using CX-One component
software such as the CX-Programmer.
• Supports 1:1 connections only.
• The Programming Device’s baud rate
Host Link (SYSWAY)
This is a general host computer communications protocol, which supports 1:1 and 1:N connections.
• Host link operates at a slower speed than peripheral bus.
• Host link supports 1:N connections as well as long-distance connections when RS-422A/RS-485 is used for a connection
through a modem or optical adapter.
■ Programming Console
Product name
Programming Console
Programming Console Key
Sheet
Programming
Console
Connecting
Cable
Cable model
(Separate item)
Specifications
Can be connected to the
CPU Unit’s peripheral port
only. Cannot be connected to
CS1W-CN224: 2 m
the RS-232C port.
CS1W-CN624: 6 m
A CS1W-KS001-E
Programming Console Key
Sheet is required
(sold separately).
Connection configuration
Model
CS1W-CN224 (2 m)
CS1W-CN624 (6 m)
Peripheral port
C200H-PRO27-E
Programming
Console
Key Sheet
CS1W-KS001
Programming
Console
C200H-PRO27
For the following Programming Consoles: C200H-PRO27
CS1W-KS001-E
For C200H-PRO27 connection, Cable length: 2 m
CS1W-CN224
For C200H-PRO27 connection, Cable length: 6 m
CS1W-CN624
■ Connecting Cables for NS-series PTs
Specifications
Product name
Connection configuration
Cable length
Model
Connecting Cables between an NS-series PT and the RS-232C port of CPU Unit or
Serial Communications Board/Unit
Connecting Cables for
NS-series PTs
Serial
Communications
Board's
NS-series PT
XW2Z-200T
5m
XW2Z-500T
2m
XW2Z-200T-2
5m
XW2Z-500T-2
RS-232C
RS-232C Cable
XW2Z-200T (2 m)
XW2Z-500T (5 m)
CPU Unit's built-in
RS-232C port
Connecting Cables between an NS-series PT and the peripheral port of CPU Unit
24
2m
Programmable Controllers
CS1G/H
Accessories and Maintenance Parts
Product name
Memory Cards
Specifications
HMC-EF183
Memory Card Adapter (Adapts to a computer’s PCMCIA card slot.)
HMC-AP001
Product name
Battery Set
I/O Terminal Cover
Model
Flash Memory, 128 MB
Specifications
Model
Battery for CS-series maintenance
Note 1: A battery is included with the CPU Unit as standard equipment.
2: The battery life is 5 years at an ambient temperature of 25°C, although the lifetime
can be as short as 1.1 years under adverse temperature and power conditions.
3: Use a replacement battery that was manufactured within the last two years.
CS1W-BAT01
Cover for 10-pin Terminal Blocks
C200H-COV11
Protective cover for unused Power Supply Unit connector in C200H Backplane
C500-COV01
Protective cover for unused CS-series Unit connector in Backplane
CV500-COV01
For unused I/O slot spaces in the CS1W-BC@@3/BI@@3 or C200HW-BI@@@ Backplanes
C200H-SP001
For unused I/O slot spaces in the CS1W-BC@@2/BI@@2 or CS1W-BC@@3/BI@@3
Backplanes
CS1W-SP001
Connector Cover
Space Units
Backplane Insulation Plate
(for C200HX/HG/HE
Expansion I/O Backplane)
Used to electrically insulate the Backplane from the control
panel as a noise countermeasure.
10 slots
C200HW-ATTA2
8 slots
C200HW-ATT82
5 slots
C200HW-ATT52
3 slots
C200HW-ATT32
Contact relays
24 VDC
For Relay Output Unit C200H-OC221/222/223/224/225
G6B-1174P-FD-US-M DC24
Programming
Console Mounting
Bracket
Use to mount a C200H-PRO27 Programming Console in a control panel.
C200H-ATT01
Terminator
Connected to last Long-distance Expansion Rack (for CS1W-IC102). Two are included with
the CS1W-IC102 I/O Control Unit.
CV500-TER01
RS-422A Converter
Converts RS-233C to RS-422A/RS-485.
CJ1W-CIF11
RS-232C/RS-422A Link Adapter
RS-232C × 1 port
RS-422A terminal block
NT-AL001
DIN Track Mounting Accessories
Product name
Specifications
Model
DIN Track
Mounting Bracket
1 set (package of 2 brackets)
C200H-DIN01
Track length: 50 cm
Height: 7.3 mm
PFP-50N
DIN Track
Track length: 1 m
Height: 7.3 mm
PFP-100N
Track length: 1 m
Height: 16 mm
PFP-100N2
End Plate
PFP-M
Note: Order in lots of 10.
Spacer
PFP-S
Programmable Controllers
CS1G/H
25
Basic I/O Units
CS1 Basic I/O Units
■ Input Units
Words
required
Mountable Racks
Unit type
Product name
CPU Rack
Specifications
CS1W-BC
C200HX/
HG/HE
Expansion
I/O Rack
CS1 Expansion
CS1 LongRack
distance
CS1W-BI
Expansion
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
(I/O bits:
CIO 0000 to
CIO 0319)
Current
consumption
(A)
Model
5V
26 V
system system
@@3
@@2
24 VDC, 7 mA,
16 inputs
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.10
---
CS1W-ID211
24 VDC, 6 mA,
32 inputs
Yes
Yes
No
Yes
Yes
Yes
No
2 words
0.15
---
CS1W-ID231
24 VDC, 7 mA,
64 inputs
Yes
Yes
No
Yes
Yes
Yes
No
4 words
0.15
---
CS1W-ID261
24 VDC, approx.
5 mA, 96 inputs
Yes
Yes
No
Yes
Yes
Yes
No
6 words
0.20
---
CS1W-ID291
100 to 120 VAC,
AC Input Unit 16 inputs
100 to 120 VDC,
16 inputs
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.11
---
CS1W-IA111
200 to 240 VAC,
16 inputs
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.11
---
CS1W-IA211
DC Input Unit
CS1 Basic
I/O Units
■ Output Units
Mountable Racks
CPU Rack
Unit type
Product name
Specifications
CS1W-BC
CS1 Expansion
CS1 LongRack
distance
CS1W-BI
Expansion
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
Words
required
Current
consumption
(A)
Model
5V
system
26 V
system
CS1W-OC201
@@3
@@2
250 VAC or 120 VDC,
Relay Output 2 A max.
Units
Independent contacts,
8 outputs
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.10
250 VAC or 120 VDC,
2 A max.
16 outputs
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.13
0.006
per
simultaneously
ON
outputs
12 to 24 VDC,
0.5 A
16 outputs
Sinking
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.17
---
CS1W-OD211
24 VDC, 0.5 A
16 outputs
Sourcing
Yes
Yes
No
Yes
Yes
Yes
No
1 word
0.17
---
CS1W-OD212
12 to 24 VDC,
0.5 A
32 outputs
Sinking
Yes
Yes
No
Yes
Yes
Yes
No
2 words
0.27
---
CS1W-OD231
24 VDC, 0.5 A
32 outputs
Sourcing
Yes
Yes
No
Yes
Yes
Yes
No
2 words
0.27
---
CS1W-OD232
12 to 24 VDC,
0.3 A
64 outputs
Sinking
Yes
Yes
No
Yes
Yes
Yes
No
4 words
0.39
---
CS1W-OD261
24 VDC, 0.3 A
64 outputs
Sourcing
Yes
Yes
No
Yes
Yes
Yes
No
4 words
0.39
---
CS1W-OD262
12 to 24 VDC,
0.1 A
96 outputs
Sinking
Yes
Yes
No
Yes
Yes
Yes
No
6 words
0.48
---
CS1W-OD291
12 to 24 VDC,
0.1 A
96 outputs
Sourcing
Yes
Yes
No
Yes
Yes
Yes
No
6 words
0.48
---
CS1W-OD292
1 word
0.23
max.
(0.07 +
0.02 ×
number
of ON
points)
---
CS1W-OA201
1 word
0.406
max.
(0.07 +
0.021 ×
number
of ON
points)
---
CS1W-OA211
Transistor
Output Units
CS1 Basic
I/O Units
Triac Output
Units
250 VAC, 2 A max.
8 outputs
250 VAC, 0.5 A max.
16 outputs
26
C200HX/
HG/HE
Expansion
I/O Rack
Yes
Yes
Programmable Controllers
Yes
Yes
No
No
CS1G/H
Yes
Yes
Yes
Yes
Yes
Yes
No
No
CS1W-OC211
■ I/O Units
Mountable Racks
Product
name
Unit type
CPU Rack
Specifications
CS1W-BC
@@3
@@2
C200HX/
HG/HE
Expansion
I/O Rack
CS1 Expansion
CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
Words
required
Current
consumption
(A)
5V
system
Model
26 V
system
24 VDC, 6 mA
32 inputs
DC Input/
Transistor
Output Unit
CS1W-MD261
12 to 24 VDC, 0.3 A
32 outputs
Sourcing
Yes
Yes
No
Yes
Yes
Yes
No
24 VDC, 6 mA
32 inputs
2 input
words
and 2
output
words
0.27
---
CS1W-MD262
24 VDC, 0.3 A
32 outputs
Sourcing
24 VDC, approx. 5 mA
48 inputs
CS1 Basic
I/O Units
CS1W-MD291
12 to 24 VDC, 0.1 A
48 outputs
Sinking
Yes
Yes
No
Yes
Yes
Yes
No
24 VDC, approx. 5 mA
48 inputs
3 input
words
and 3
output
words
0.35
---
CS1W-MD292
12 to 24 VDC, 0.1 A
48 outputs
Sourcing
TTL I/O Unit
5 VDC
32 inputs, 32 outputs
Yes
Yes
No
Yes
Yes
Yes
No
2 input
words
and 2
output
words
0.27
---
CS1W-MD561
Note: The C200H-ID001 (8 no-voltage contact inputs, NPN) and C200H-ID002 (8 no-voltage contact inputs, PNP) cannot be used.
● Applicable Connectors
Connector for CS1 Basic I/O Units (32 inputs, 64 inputs, 32 outputs, 64 outputs, 32 inputs/32 outputs)
Name
Applicable
Connectors
Connection
Applicable Units
Model
Soldered
FCN-361J040-AU Connector
FCN-360C040-J2 Connector cover
C500-CE404
(Included with Unit)
Crimped
FCN-363J040
Housing
FCN-363J-AU
Contact
FCN-360C040-J2 Connector cover
C500-CE405
Pressure welded
FCN-367J040-AU/F
C500-CE403
Connector for CS1 Basic I/O Units (96 inputs, 96 outputs, 48 inputs/48 outputs)
Name
Applicable
Connectors
Connection
Applicable Units
Model
Soldered
FCN-361J056-AU Connector
FCN-360C056-J3 Connector cover
CS1W-CE561
(Included with Unit)
Crimped
FCN-363J056
Housing
FCN-363J-AU
Contact
FCN-360C056-J3 Connector cover
CS1W-CE562
Pressure welded
FCN-367J056-AU
CS1W-CE563
Programmable Controllers
CS1G/H
27
■ Interrupt Input Unit
Specifications
Unit type
Product
name
Mountable Racks
CS1
Expansion
CPU Rack
Input pulse
C200HX/
CS1 LongRack
External
width
I/O
Input Input
HG/HE
distance
connecCS1W-BC Expansion CS1W-BI Expansion
points voltage current
tion
I/O Rack
Rack
ON OFF
@@3 @@2
@@3 @@2
time time
SYSMAC Words
BUS
required
Slave
Rack
Current
consumption
(A)
Model
5V
26 V
system system
Interrupt
Input Unit
CS1 Basic
I/O Units
16
inputs
24
VDC
7 mA
Remov0.1 0.5
able
ms
ms
terminal
max. max.
block
Yes
Yes
*
*
Yes Yes
No
*
Yes
No
1 word
0.10
---
CS1W-INT01
* Interrupt inputs are not supported on these Racks (i.e., used as normal I/O Unit).
■ Quick-response Input Unit
Specifications
Unit type
Product
name
Mountable Racks
CS1
CPU Rack C200HX/
Expansion CS1 LongInput pulse External
I/O
Input Input
HG/HE
Rack
distance
width
connecpoints voltage current
Expansion
Expansion
CS1W-BC
CS1W-BI
(ON time)
tion
I/O Rack
Rack
@@3 @@2
@@3 @@2
Quickresponse
Input Unit
16
inputs
CS1 Basic
I/O Units
24
VDC
7 mA
Removable
terminal
block
0.1 ms
max.
Yes
Yes
No
Yes
Yes
SYSMAC Words
BUS
required
Slave
Rack
Yes
No
1 word
Current
consumption
(A)
Model
5V
26 V
system system
0.10
---
CS1W-IDP01
■ B7A Interface Unit
Mountable Racks
Unit type
Product
name
Specifications
CS1W-BC
B7A Interface
Unit
CS1 Basic
I/O Unit
CPU Rack
C200HX/
HG/HE
Expansion
I/O Rack
CS1 Expansion
CS1 LongRack
distance
CS1W-BI
Expansion
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
Words required
Current
consumption
(A)
5V
system
26 V
system
Model
@@3
@@2
32 inputs
Yes
Yes
No
Yes
Yes
Yes
No
2 words
0.09
---
CS1W-B7A12
32 outputs
Yes
Yes
No
Yes
Yes
Yes
No
2 words
0.09
---
CS1W-B7A02
0.09
---
CS1W-B7A21
0.09
---
CS1W-B7A22
16 inputs/outputs
Yes
Yes
No
Yes
Yes
Yes
No
1 input word and
1 output word
32 inputs/outputs
Yes
Yes
No
Yes
Yes
Yes
No
2 input words and
2 output words
■ Safety Relay Unit
Specifications
Unit type
Product
name
Contact Number
CPU Rack
Power Number
External
type
of
Function supply of input
connec(Safety general
voltage words
tions CS1W-BC
output) inputs
@@3 @@2
Safety
Relay Unit
CS1Basic
I/O Units
28
Mountable Racks
Emergency
stop Unit
24
VDC
1 word
4
or 2
DPST- inputs/
words
NO
com(Shared
mon
inputs)
Programmable Controllers
Removable
terminal
block
Yes
CS1G/H
Yes
C200HX/
HG/HE
Expansion I/O
Rack
No
CS1
Expansion CS1 Longdistance
Rack
Expansio
CS1W-BI
n Rack
@@3 @@2
Yes
Yes
Yes
SYSMAC Words
BUS
required
Slave
Rack
No
1 word
Current
consumption
(A)
Model
5V
26 V
system system
0.10
---
CS1W-SF200
C200H Basic I/O Units and C200H Group-2 High-density I/O Units
■ Input Units
Words
required
Mountable Racks
Unit type
Product
name
Specifications
CPU Rack
CS1W-BC
DC Input
Unit
AC Input
Unit
C200H
Basic I/O
Units
DC Input
Unit
CS1 Expansion
CS1 LongRack
distance
CS1W-BI
Expansion
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
(I/O bits:
CIO 0000 to
CIO 0319)
Model
5V
26 V
system system
@@3
@@2
12 to 24 VDC, 8 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-ID211
24 VDC, 16 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-ID212
100 to 120 VAC, 8 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IA121
100 to 120 VAC, 16 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IA122
200 to 240 VAC, 8 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IA221
200 to 240 VAC, 16 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IA222
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IM211
24 VAC/VDC, 16 inputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
---
C200H-IM212
24 VDC, 32 inputs
Yes
No
Yes
Yes
No
No
No
2 words
0.10
---
C200H-ID216
24 VDC, 64 inputs
Yes
No
Yes
Yes
No
No
No
4 words
0.12
---
C200H-ID217
24 VDC, 32 inputs, 6 mA
Yes
No
Yes
Yes
No
No
No
2 words
0.10
---
C200H-ID218
24 VDC, 64 inputs, 6 mA
Yes
No
Yes
Yes
No
No
No
4 words
0.12
---
C200H-ID219
AC/DC Input
Unit
12 to 24 VAC/VDC, 8 inputs
C200H
Group-2
Highdensity
I/O Units
C200HX/
HG/HE
Expansion
I/O Rack
Current
consumption
(A)
Programmable Controllers
CS1G/H
29
■ Output Units
Mountable Racks
Unit type
Product
name
CPU Rack
Specifications
CS1W-BC
Relay
Contact
Output Unit
C200H
Basic I/O
Units
Transistor
Output Unit
Triac Output
Unit
C200H
Group-2
Highdensity
I/O Units
30
Transistor
Output Units
C200HX/
HG/HE
Expansion
I/O Rack
CS1 Expansion
CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
Words
required
Yes
1 word
Current consumption
(A)
Model
5V
system
26 V
system
@@3
@@2
250 VAC or 24 VDC,
2 A max.
8 outputs
Yes
No
250 VAC or 24 VDC,
2 A max.
12 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
250 VAC or 24 VDC,
2 A max.
16 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.05
0.075 per 8
simultaneously
ON outputs
C200H-OC225
250 VAC or 24 VDC,
2 A max.
Independent
contacts: 5 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
0.075 per 8
simultaneously
ON outputs
C200H-OC223
250 VAC or 24 VDC,
2 A max.
Independent
contacts: 8 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
0.075 per 8
simultaneously
ON outputs
C200H-OC224
12 to 48 VDC, 1 A
8 outputs
Sinking
Yes
No
Yes
Yes
No
No
Yes
1 word
0.14
---
C200H-OD411
24 VDC, 2.1 A
8 outputs
Sinking
Yes
No
Yes
Yes
No
No
Yes
1 word
0.14
---
C200H-OD213
5 to 24 VDC, 0.3 A
8 outputs
Sourcing
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
24 VDC, 0.3 A
12 outputs
Sinking
Yes
No
Yes
Yes
No
No
Yes
1 word
0.16
5 to 24 VDC, 0.3 A
12 outputs
Sourcing
Yes
No
Yes
Yes
No
No
Yes
1 word
0.01
24 VDC, 0.3 A
16 outputs
Sinking
Yes
No
Yes
Yes
No
No
Yes
1 word
0.18
---
C200H-OD212
250 VAC, 1.2 A max.
8 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.18
---
C200H-OA223
250 VAC, 0.5 A max.
12 outputs
Yes
No
Yes
Yes
No
No
Yes
1 word
0.27
---
C200H-OA224
4.5 to 26.4 V,
16 to 100 mA
32 outputs
Sinking
Yes
No
Yes
Yes
No
No
No
2 words
0.27
---
C200H-OD218
4.5 to 26.4 V,
16 to 100 mA
64 outputs
Sinking
Yes
No
Yes
Yes
No
No
No
4 words
0.48
---
C200H-OD219
Yes
Yes
No
No
0.01
C200H-OC221
0.075 per 8
simultaneously
ON outputs
Programmable Controllers
CS1G/H
C200H-OC222
0.075 per 8
simultaneously
ON outputs
--0.075 per 8
simultaneously
ON outputs
C200H-OD216
C200H-OD211
C200H-OD217
■ Analog Timer Unit
Mountable Racks
Unit type
Product
name
Specifications
CPU Rack
CS1W-BC
@@3
@@2
Yes
No
C200HX/
HG/HE
Expansion
I/O Rack
CS1 Expansion
CS1 LongRack
distance
CS1W-BI
Expansion
Rack
@@3
@@2
SYSMAC
BUS Slave
Rack
Words
required
Yes
1 word
Current
consumption
(A)
Model
5V
26 V
system system
Analog
Timer Unit
C200H
Basic I/O
Units
4-point timer
Yes
Yes
No
No
0.06
Programmable Controllers
---
C200H-TM001
CS1G/H
31
Special I/O Units, CPU Bus Units, and Inner Boards
CS1 Special I/O Units, CPU Bus Units, and Inner Boards
■ Temperature Sensor Input Units (Process I/O Units)
Specifications
Unit type
Product
name
I/O
points
Signal
range
selection
Signal
range
B, E, J, K,
L, N, R, S,
4
4
T, U,
indepeninputs
WRe5-26,
Isolated-type
dent
PL II,
Thermocou±100 mV
ple Input
Units
CS1
Special
I/O Units
CS1
CS1
CPU Rack C200HX/ Expansion LongHG/HE
ConverRack
disExternal
Expansion
tance
connection CS1W-BC
CS1W-BI
sion I/O
speed
ExpanRack
sion
@@3 @@2
@@3 @@2
Rack
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Current
consumption
(A)
Model
5V
26 V
system system
20 ms/
4 inputs,
10 ms/
2 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.12
0.08
CS1W-PTS11
250 ms/
4 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.25
---
CS1W-PTS51
8
8
R, S, K, J, 250 ms/
indepeninputs
T, L, B
8 inputs
dent
Yes
Yes
No
Yes
Yes
Yes
No
0.18
0.06
CS1W-PTS55
4
B, E, J, K,
4
150 ms/
indepen- N, R, S, T,
inputs
4 inputs
dent
±80mV
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.15
CS1W-PTS01-V1
Removable
20 ms/
terminal
4 inputs,
Yes
block
10 ms/
2 inputs
Yes
No
Yes
Yes
Yes
No
0.12
0.07
CS1W-PTS12
4
4
R, S, K, J,
indepeninputs
T, L, B
dent
Pt100 Ω
4
(JIS, IEC),
4
indepenJPt100 Ω,
Isolated-type inputs
dent
Pt50 Ω,
Resistance
Ni508.4 Ω
Thermome-
1 unit
number’s
words
4
Pt100 Ω
4
250 ms/
indepen- (JIS, IEC),
inputs
4 inputs
dent
JPt100 Ω
Yes
Yes
No
Yes
Yes
Yes
No
0.25
---
CS1W-PTS52
8
Pt100 Ω
8
250 ms/
indepen- (JIS, IEC),
inputs
8 inputs
dent
JPt100 Ω
Yes
Yes
No
Yes
Yes
Yes
No
0.18
0.06
CS1W-PTS56
4
Pt100 Ω
4
100 ms/
indepen- (JIS, IEC),
inputs
4 inputs
dent
JPt100 Ω
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.15
CS1W-PTS02
Isolated-type
Resistance
4
4
100 ms/
Thermomeindepen- Ni508.4 Ω
inputs
4 inputs
ter Input Unit
dent
(Ni508.4 W)
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.15
CS1W-PTS03
ter Input
Units
32
Mountable Racks
Programmable Controllers
CS1G/H
■ Analog Input Units
● Analog Input Units
Specifications
Unit type
Product
name
Analog
Input Units
Signal
I/O
range
points selection
Signal
range
1 to 5 V,
0 to 5 V,
4
4
0 to 10 V,
inde-10 to
inputs
pendent
10 V, 4 to
20 mA
8
1 to 5 V,
8
inde0 to 5 V,
inputs
pendent 0 to 10 V,
-10 to
10 V, 4 to
16
16
20 mA
indeinputs
pendent
CS1
Special
I/O Units
ConnectorTerminal
Block
Conversion Unit
for CS1WAD161
Mountable Racks
CS1
CS1
C200HX/
CPU Rack
Expansion LongHG/HE
Conver- External
ResoluRack
distance
Expansion connection
CS1W-BC sion I/O CS1W-BI Expanspeed
tion
sion
@@3 @@2 Rack
@@3 @@2 Rack
1/8,000
(Can
also be
set to
1/4,000.)
250 µs/
input
(Can
also be
set to
1 ms/
input.)
1/8,000
(Can
also be
set to
1/4,000.)
250 µs/
input
(Can
also be
set to
1 ms/
input.)
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Removable
terminal
block
Yes
Removable
terminal
block
Yes
Yes
No
Yes
Yes
Yes
No
MIL
connector
Yes
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Current
consumption
(A)
Model
5V
26 V
system system
0.12
0.09
CS1W-AD041-V1
0.12
0.09
CS1W-AD081-V1
0.15
0.06
CS1W-AD161
1 unit
number’s
words
2 unit
numbers’
words
Slim terminal block
Terminal: 34, dimension: 128 x 40 x 39 mm
XW2D-34G6
Connection cable
Cable length: 2 m
XW2Z-200C
---
● Isolated-type DC Input Units (Process I/O Units)
Specifications
Unit type
Product
name
Mountable Racks
CS1
C200HX/ Expansion
CS1 LongHG/HE
Rack
Conversion External
distance
Expanspeed
connection
Expansion
CS1W-BC sion I/O
CS1W-BI
Rack
Rack
@@3 @@2
@@3 @@2
CPU Rack
I/O
points
Signal
range
Current
consumption
No. of
SYSMAC unit
(A)
BUS
numbers
Slave
allocated
5V
26 V
Rack
system system
Model
4 to 20 mA,
0 to 20 mA,
0 to 10 V,
±10 V,
4
0 to 5 V,
inputs
±5 V,
1 to 5 V,
0 to 1.25 V,
±1.25 V
20 ms/
4 inputs, 10
ms/
2 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.12
0.12
CS1W-PDC11
4 to 20 mA,
8
0 to 10 V,
inputs 0 to 5 V,
1 to 5 V,
250 ms/
8 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.18
0.06
CS1W-PDC55
4 to 20 mA,
0 to 20 mA,
1 to 5 V,
4
0 to 5 V,
inputs
±5 V,
0 to 10 V,
±10 V
100 ms/
4 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.16
CS1W-PDC01
4
4 to 20 mA,
inputs 1 to 5 V
100 ms/
4 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.16
CS1W-PTW01
Power
Transducer
Input Unit
8
0 to 1 mA,
inputs ±1 mA
200 ms/
8 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.08
CS1W-PTR01
DC Analog
Input Unit
(100 mV)
8
0 to 100 mV, 200 ms/
inputs ±100 mV
8 inputs
Yes
Yes
No
Yes
Yes
Yes
No
0.15
0.08
CS1W-PTR02
Isolatedtype DC
Input Units
CS1
Special
I/O Units
Removable
terminal
block
1 unit
number’s
words
Isolatedtype 2-Wire
Transmitter
Input Unit
Programmable Controllers
CS1G/H
33
■ Analog Output Units
● Analog Output Units
Specifications
Unit type
Product
name
Analog
Output
Units
CS1
Special
I/O Units
I/O
points
Signal
range
selection
Signal
range
Mountable Racks
CS1
CPU Rack C200HX/
Expansion CS1 LongConver- External
Rack
HG/HE
distance
Resosion connecExpansion
Expansion
lution
speed
tion
CS1W-BC
CS1W-BI
I/O Rack
Rack
@@3 @@2
@@3 @@2
1 to 5 V,
0 to 5 V,
4
1 ms/
4
0 to 10 V,
1/4000
indeoutput
outputs
pendent -10 to 10 V,
4 to 20 mA
1 to 5 V,
8
8
1 ms/
0 to 5 V,
inde1/4000
outputs
output
0 to 10 V,
pendent
-10 to 10 V
Removable
terminal
block
8
8
1 ms/
inde4 to 20 mA 1/4000
outputs
output
pendent
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
Yes
No
1 unit
number’s
words
Current
consumption
(A)
Model
5V
26 V
system system
0.13
0.18
CS1W-DA041
0.13
0.18
CS1W-DA08V
0.13
0.25
CS1W-DA08C
● Isolated-type Control Output Units (Process I/O Units)
Mountable Racks
Specifications
Unit type
Product
name
I/O
points
Signal
range
selection
Signal
range
Conver- External
sion
connecspeed
tion
CPU Rack
C200HX/
HG/HE
Expansion
I/O Rack
CS1W-BC
@@3 @@2
CS1
Special
I/O Units
Isolatedtype
Control
Output
Units
4
4 to
4
inde20 mA,
outputs
pendent 1 to 5V
0 to 10V,
±10V,
4
4
0 to 5V,
indeoutputs
±5V,
pendent
0 to 1V,
±1V
100 ms/
outputs
40 ms/
outputs
Yes
Removable
terminal
block
Yes
No
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
Yes
Yes
Yes
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
No
Current
consumption
(A)
Model
5V
26 V
system system
0.15
0.16
CS1W-PMV01
0.12
0.12
CS1W-PMV02
1 unit
number’s
words
Yes
Yes
No
Yes
Yes
Yes
No
■ Analog I/O Units
Specifications
Unit
type
Product
name
Analog
I/O Units
CS1
Special
I/O Units
34
Signal
I/O
range
points selection
4
inde4 inputs
pendent
4
inde4
outputs pendent
Signal
range
Mountable Racks
CS1
CPU Rack C200HX/ Expansion CS1 LongConver- External
Rack
ResoluHG/HE
distance
sion connection
Expansion
Expansion
CS1W-BC
CS1W-BI
speed
tion
I/O Rack
Rack
@@3 @@2
@@3 @@2
1 to 5V,
0 to 5V,
0 to 10V,
-10 to 10V,
4 to 20 mA
1/4000
1 to 5V,
0 to 5V,
0 to 10V,
-10 to 10V
1/4000
1 ms/
output
1 ms/
output
Programmable Controllers
Removable
terminal
block
Yes
CS1G/H
Yes
No
Yes
Yes
Yes
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
No
1 unit
number’s
words
Current
consumption
(A)
Model
5V
26 V
system system
0.20
0.20
CS1W-MAD44
■ Isolated-type Pulse Input Units (Process I/O Units)
Mountable Racks
CPU Rack
Unit type
Product name
C200HX/
HG/HE
Expansion
I/O Rack
Specifications
CS1W-BC
@@3
@@2
Yes
Yes
CS1
Expansion
Rack
CS1W-BI
@@3
@@2
Yes
Yes
CS1 Longdistance
Expansion
Rack
SYSMAC
BUS Slave
Rack
Yes
No
Current
consumption
(A)
No. of unit
numbers
allocated
Model
5V
26 V
system system
Isolated-type
Pulse Input Unit
CS1
Special
I/O Units
4 pulse inputs
No
1 unit
number’s
words
0.20
0.16
CS1W-PPS01
■ Loop Control Board/Loop Control Unit
Mountable Racks
Unit type
Product name
Specifications
Loop Control
Board
CS1 Inner
Board
50 blocks max. (total control
blocks and operation blocks)
*1
*1
Yes Yes
RDY
EXEC
COMM
CS1
Expansion CS1 Longdistance
Rack
Expansion
CS1W-BI
Rack
@@3 @@2
No
No
SYSMAC
BUS Slave
Rack
No
No
Current
consumption
(A)
No. of unit
numbers
allocated
Model
5V
26 V
system system
*2
0.22
---
CS1W-LCB01
*2
0.22
---
CS1W-LCB05
---
500 blocks max. (total control
blocks and operation blocks)
PORT
LCB01
*1.
*2.
CPU Rack C200HX/
HG/HE
Expansion
CS1W-BC
I/O Rack
@@3 @@2
Mount a CS1W-LCB01/05 Loop Control Board in a CS1G/H-CPU@@H CPU Unit or a CS1D-CPU@@S CS1D Duplex System CPU Unit.
NT-AL001 Link Adapters consume an additional 0.15 A each when used.
■ High-speed Counter Units
Specifications
Unit type
Product
name
High-speed
Counter
Units
Number Encoder A and B
of count inputs, and Z pulse
channels input signal
2
CS1
Special
I/O Units
Input voltage: 5 VDC,
12 VDC, or 24 VDC
(only 1 axis for 5 V or
12 V input)
RS-422 line driver
4
Input voltage: 5 VDC,
12 VDC, or 24 VDC
(up to 2 axes for 5 V
or 12 V input)
RS-422 line driver
Mountable Racks
CS1
CPU Rack C200HX/
Expansion CS1 LongMaximum
Rack
HG/HE
distance
count
Expansion
Expansion
speed
CS1W-BC
CS1W-BI
I/O Rack
Rack
@@3 @@2
@@3 @@2
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Current
consumption
(A)
Model
5V
26 V
system system
50 kHz
Yes
Yes
No
Yes
Yes
Yes
No
0.36
---
CS1W-CT021
0.45
---
CS1W-CT041
4 unit
numbers’
words
500 kHz
50 kHz
Yes
Yes
No
Yes
Yes
Yes
No
500 kHz
Programmable Controllers
CS1G/H
35
■ Customizable Counter Units
Mountable Racks
Unit type
Product name
Customizable
Counter Units
CS1
Special
I/O Units
CPU Rack C200HX/
HG/HE
Expansion
CS1W-BC
I/O Rack
@@3 @@2
Specifications
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
SYSMAC
BUS Slave
Rack
Two-axis pulse input
Two-axis pulse output
12 DC inputs
8 transistor outputs
Yes
Yes
No
Yes
Yes
Yes
No
Single-axis pulse input
1 analog input
2 analog outputs
12 DC inputs
8 transistor outputs
Yes
Yes
No
Yes
Yes
Yes
No
Two-axis pulse input
2 analog outputs
12 DC inputs
8 transistor outputs
Yes
Yes
No
Yes
Yes
Yes
12 DC inputs
8 transistor outputs
Yes
Yes
No
Yes
Yes
Yes
No. of unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
0.80
---
CS1W-HCP22-V1
0.75
0.15
CS1W-HCA12-V1
No
0.75
0.15
CS1W-HCA22-V1
No
0.60
---
CS1W-HIO01-V1
1 unit
number’s
words
■ Position Control Units
Mountable Racks
Specifications
Unit type
Product name
Control output
interface
Pulse-train,
Position Control open-collector
outputs
Units
Pulse-train, linedriver outputs
CPU Rack C200HX/
HG/HE
Expansion
CS1W-BC
Number
I/O Rack
of axes @@3 @@2
SYSMAC
BUS Slave
Rack
1 axis
Yes
Yes
No
Yes
Yes
Yes
No
2 axes
Yes
Yes
No
Yes
Yes
Yes
No
4 axes
Yes
Yes
No
1 axis
Yes
Yes
No
Yes
Yes
Yes
No
2 axes
Yes
Yes
No
Yes
Yes
Yes
No
4 axes
Relay Unit for
Servo
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Current
consumption
(A)
Model
5V
26 V
system system
1 unit
number’s
words
2 unit
numbers’
words
1 unit
number’s
words
2 unit
numbers’
words
0.25
---
CS1W-NC113
0.25
---
CS1W-NC213
0.36
---
CS1W-NC413
0.25
---
CS1W-NC133
0.25
---
CS1W-NC233
0.36
---
CS1W-NC433
For use with the CS1W-NC1@3
Number of axes supported: 1
XW2B-20J6-1B
For use with the CS1W-NC2@3/
NC4@3
Number of axes supported: 2
XW2B-40J6-2B
For use with the CS1W-NC@@3
Number of axes supported: 2, with communications support
For use with the
CS1W-NC113
CS1
Special
I/O Units
Connectable Servo Drive:
G5 Series, G Series, W Series *,
or SMARTSTEP 2
Number of axes
supported: 1
Connectable Servo Drive:
SMARTSTEP Junior or A Series
Open-collector
output
For use with the
CS1W-NC213/
NC413
Servo Relay Unit
Connecting
Cable (Position
Control Unit end)
For use with the
CS1W-NC133
Connectable Servo Drive:
G5 Series, G Series, W Series *,
or SMARTSTEP 2
Number of axes
supported: 2
Connectable Servo Drive:
SMARTSTEP Junior or A Series
Connectable Servo Drive:
G5 Series, G Series, W Series *,
or SMARTSTEP 2
Number of axes
supported: 1
Connectable Servo Drive:
SMARTSTEP Junior or A Series
Line-driver
outputs
Connectable Servo Drive:
G5 Series, G Series, W Series *,
or SMARTSTEP 2
For use with the
CS1W-NC233/
NC433
Connectable Servo Drive:
SMARTSTEP Junior or A Series
* W-series is the discontinuation model in March 2013.
36
No
No. of unit
numbers
allocated
Programmable Controllers
CS1G/H
Number of axes
supported: 2
XW2B-40J6-4A
Cable length: 0.5 m
XW2Z-050J-A6
Cable length: 1 m
XW2Z-100J-A6
Cable length: 0.5 m
XW2Z-050J-A8
Cable length: 1 m
XW2Z-100J-A8
Cable length: 0.5 m
XW2Z-050J-A7
Cable length: 1 m
XW2Z-100J-A7
Cable length: 0.5 m
XW2Z-050J-A9
Cable length: 1 m
XW2Z-100J-A9
Cable length: 0.5 m
XW2Z-050J-A10
Cable length: 1 m
XW2Z-100J-A10
Cable length: 0.5 m
XW2Z-050J-A12
Cable length: 1 m
XW2Z-100J-A12
Cable length: 0.5 m
XW2Z-050J-A11
Cable length: 1 m
XW2Z-100J-A11
Cable length: 0.5 m
XW2Z-050J-A13
Cable length: 1 m
XW2Z-100J-A13
■ Position Control Unit with MECHATROLINK-II interface
Mountable Racks
Specifications
Unit type
CPU Rack C200HX/
HG/HE
Expansion
Number CS1W-BC I/O Rack
of axes @@3 @@2
Product name
Control output
interface
Position Control
Unit with
MECHATROLINK-II
interface
Control commands
are sent using
2 axes
MECHATROLINK-II
communications.
Direct operation
from ladder
4 axes
program.
Control modes:
Position control,
speed control,
16 axes
and torque
control
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
SYSMAC
BUS Slave
Rack
No. of unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
CS1W-NC271
Yes
Yes
No
Yes
Yes
Yes
No
1 unit
number’s
words
0.36
---
CS1W-NC471
CS1W-NCF71
CS1 CPU
Bus Unit
MECHATROLINK-II To connect MECHATROLINK-II compliant devices (Yaskawa Electric Corporation)
Cables
The model numbers at the right are used to order from OMRON.
Cable length: 0.5 m
FNY-W6003-A5
Cable length: 1 m
FNY-W6003-01
Cable length: 3 m
FNY-W6003-03
Cable length: 5 m
FNY-W6003-05
Cable length: 10 m
FNY-W6003-10
Cable length: 20 m
FNY-W6003-20
Cable length: 30 m
FNY-W6003-30
MECHATROLINK-II Terminating resistance for MECHATROLINK-II (Yaskawa Electric Corporation)
Terminator
The model number at the right is used to order from OMRON.
FNY-W6022
MECHATROLINK-II Communications repeater.
Repeater
(Yaskawa Electric Corporation)
JEPMC-REP2000-E
■ Motion Control Units
Mountable Racks
Specifications
Unit type
Product name
CPU Rack
Control output Number CS1W-BC
interface
of axes @@3 @@2
C200HX/
HG/HE
Expansion
I/O Rack
CS1
Expansion CS1 Longdistance
Rack
Expansion
CS1W-BI
Rack
@@3 @@2
No. of unit
SYSMAC numbers
BUS Slave allocated
Rack
Yes
Yes
No
Yes
Yes
Yes
Model
5V
system
26 V
system
No
5 unit
numbers’
words
0.70
(1.00 A
when a
Teaching
Box is
connected)
---
CS1W-MC421-V1
No
3 unit
numbers’
words
0.60
(0.80 A
when a
Teaching
Box is
connected)
---
CS1W-MC221-V1
Motion Control Unit
(G-language
programming)
4 axes
Current
consumption
(A)
Analog outputs
2 axes
Yes
Yes
No
Yes
Yes
CS1
Special
I/O Units
Teaching Box
Yes
---
---
---
Teaching Box
Connecting Cable
---
---
Cable length: 2 m
ROM Cassette
---
---
MC Terminal Block For 2 axes
Conversion Unit * For 4 axes
MC Terminal Block
Conversion Unit
Cable
---
---
CV500-CN224
CVM1-MP702-V1
---
-----
CVM1-PRO01-V1
XW2B-20J6-6
XW2B-40J6-7
Cable length: 1 m
XW2Z-100J-F1
* Simplifies I/O connector wiring.
Programmable Controllers
CS1G/H
37
■ Serial Communications Boards/Serial Communications Units
Mountable Racks
Unit type
Product name
CPU Rack
Specifications
CS1W-BC
@@3 @@2
Serial
Two
Communications RS-232C
Board
ports
CS1 Inner
Board
CS1 CPU
Bus Unit
The following
communications
protocols can be
selected for each
port: protocol
macro, host link,
NT Link (1:N
mode), serial
gateway (*1), no
protocol (* 2), or
Modbus-RTU
Slave (*3).
Two
RS-422A/
485 ports
*1.
*2.
*3.
*4.
*5.
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
No. of
SYSMAC unit
BUS Slave numbers
allocated
Rack
Current
consumption
(A)
*4
Yes
Yes
*4
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Model
5V
26 V
system system
*5
0.28
One
RS-232C
port and one
RS-422A/
485 port
Serial
Two
Communications
RS-232C
Unit
ports
C200HX/
HG/HE
Expansion
I/O Rack
---
CS1W-SCB21-V1
*5
0.36
---
CS1W-SCB41-V1
*5
0.29
---
CS1W-SCU21-V1
0.40
---
CS1W-SCU31-V1
---
No
1 unit
number’s
words
Yes
Yes
No
Yes
Yes
Yes
No
The serial gateway function is supported by Serial Communications Boards and Units with unit version 1.2 or later only.
The Serial Communications Unit’s no-protocol function is supported by Serial Communications Units with unit version 1.2 or later only. In addition the CPU Unit
must be unit version 3.0 or later.
The Modbus-RTU Slave function is supported by Serial Communications Boards and Units with unit version 1.3 or later only.
One Board can be mounted in the Inner Board slot of the CPU Unit.
NT-AL001 Link Adapters consume an additional 0.15 A each when used.
■ EtherNet/IP Unit
Specifications
Unit type
Product
Communications
name
cable
Mountable Racks
CPU Rack
Communications
functions
CS1W-BC
C200HX/
HG/HE
Expansion
I/O Rack
@@3 @@2
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
No. of
SYSMAC unit
BUS Slave numbers
allocated
Rack
Current
consumption
(A)
Model
5V
26 V
system system
EtherNet/
IP Unit
STP (shielded
twisted-pair)
Tag data link
cable of category message service
5, 5e, or higher.
CS1 CPU
Bus Unit
*
Yes
*
Yes
*
Yes
No
*
Yes
*
Yes
No
1 unit
number’s
words
0.41
---
CS1W-EIP21
* Up to eight CS1W-EIP21 EtherNet/IP Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one
PLC.
■ EtherNet Unit
Mountable Racks
Unit type
Product
name
CPU Rack
Specifications
CS1W-BC
C200HX/
HG/HE
Expansion
I/O Rack
@@3 @@2
EtherNet
Unit
CS1 CPU
Bus Unit
ETN21
FINS communications
service (TCP/IP and
UDP/IP), FTP server
function, socket service,
100BASE-TX mail send service, mail
Cable
reception (remote
command reception),
auto-adjustment of PLC’s
internal clock, and server
host name specification
*
Yes
*
Yes
No
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
*
Yes
*
Yes
*
Yes
No. of
SYSMAC unit
BUS Slave numbers
allocated
Rack
No
1 unit
number’s
words
Current
consumption
(A)
Model
5V
26 V
system system
0.38
---
CS1W-ETN21
* Up to four CS1W-ETN21 Ethernet Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
38
Programmable Controllers
CS1G/H
● Industrial Switching Hubs
Specifications
Product name
Appearance
Functions
No. of
pors
Failure
detection
3
No
5
No
5
Yes
Quality of Service (QoS):
EtherNet/IP control data priority
Failure detection:
Broadcast storm and LSI error detection
10/100BASE-TX, Auto-Negotiation
Industrial Switching
Hubs
Accessories
Current
Consumption
(A)
• Power supply
connector
• Power supply
connector
• Connector for
informing error
Model
0.22
W4S1-03B
0.22
W4S1-05B
0.22
W4S1-05C
■ Controller Link Units
Mountable Racks
CPU Rack
Unit type
Product name
Specifications
CS1W-BC
Wired shielded
twisted-pair cable *1
Controller Link Optical ring H-PCF
Unit
cable *2
CS1 CPU
Bus Unit
Optical ring GI
cable *3
Controller
Wired shielded twisted-pair
Link Support cable *1
Board
H-PCF optical model
GI optical model
@@3
@@2
*4
Yes
*4
Yes
*4
Yes
*4
Yes
C200HX/
HG/HE
Expansion
I/O Rack
CS1
Expansion
Rack
CS1W-BI
CS1 Longdistance
Expansion
Rack
SYSMAC
BUS Slave
Rack
@@3
@@2
No
*4
Yes
*4
Yes
Yes
No
*4
Yes
No
*4
Yes
*4
Yes
Yes
No
*4
Yes
No
*4
Yes
*4
Yes
Yes
No
No. of
unit
numbers
allocated
1 unit
number’s
words
Current
consumption
(A)
5V
26 V
system system
0.33
---
CS1W-CLK23
0.52
---
CS1W-CLK13
0.65
---
CS1W-CLK53
• CD-ROM × 1 *5
• Installation Guide (W467) × 1
• Communications Connector × 1
•
•
•
•
CD-ROM × 1 *5
Installation Guide (W467) × 1
Optical Fiber Cable Bracket × 1
Power Supply Connector × 1
Model
3G8F7-CLK23-E
---
3G8F7-CLK13-E
3G8F7-CLK53-E
● Controller Link Options
Product name
Specifications
Relay Terminal Block for
Wired Controller Link Unit
Use for Wired Controller Link Units (set of 5).
Controller Link Repeater
Unit
Wire-to-Wire Model
CS1W-RPT01
PWR
T/R1
T/R2
Wire-to-Optical (H-PCF) Model *2
Model
CJ1W-TB101
These products are not mounted to the PLC.
(They are installed individually on DIN Rail or
with screws.)
CS1W-RPT01
CS1W-RPT02
SL1
TER SW
SW1
1 BAUD
2 RATE
ON
TER SW
SL2
DC24V
INPUT
*1.
*2.
*3.
*4.
*5.
Wire-to-Optical (GI) Model *3
CS1W-RPT03
Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5 × 2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5 × 2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)
• ESPC 1P × 0.5 mm2 (Nagaoka Electric Wire Co., Ltd.: Japanese Company)
• Li2Y-FCY2 × 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1 × 2 × AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector.
When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
• Up to four Pre-Ver. 1.2 Controller Link Units (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be mounted to the CS1
CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
• Up to eight Controller Link Units with unit version 1.2 or later (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be
mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
The CD-ROM contains the following software.
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library
Programmable Controllers
CS1G/H
39
● H-PCF Cables (For Controller Link and SYSMAC LINK)
Product name
Application and construction
Specifications
Black
(1)
(2)
(3)
(4)
(5)
(6)
Optical Fiber Cable
Optical
Connectors
(Crimp-cut)
*1.
*2.
40
Controller Link
SYSMAC LINK
SYSBUS
1.
2.
3.
4.
Optical fiber single-core cord
Tension member (plastic-sheathed wire)
Filler (plastic)
Filler surrounding signal wires (plastic,
yarn, or fiber)
5. Holding tape (plastic)
6. Heat-resistant PV sheath
Two-core
optical cable
with tension
member
Model
10 m
S3200-HCCB101
Black
50 m
S3200-HCCB501
Black
100 m
S3200-HCCB102
Black
500 m
S3200-HCCB502
Black
1,000 m
S3200-HCCB103
Orange
10 m
S3200-HCCO101
Orange
50 m
S3200-HCCO501
Orange
100 m
S3200-HCCO102
Orange
500 m
S3200-HCCO502
Orange
1,000 m
S3200-HCCO103
Controller Link: CS1W-CLK13
CS1W-CLK12-V1 *1
3G8F7-CLK13-E
3G8F7-CLK12-EV1 *1
CS1W-RPT02
SYSMAC LINK:CS1W-SLK11
3G8F7-SLK11-E
C200HW-SLK13/14 *1
Half-lock
S3200-COCF2571
Controller Link: CS1W-CLK13
CS1W-CLK12-V1 *1
3G8F7-CLK13-E
3G8F7-CLK12-EV1 *1
CS1W-RPT02
SYSMAC LINK:3G8F7-SLK11-E
Full-lock
S3200-COCF2071 *2
Discontinuation models.
Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock Cable (S3200-COCF2571) or a H-PCF
Optical Fiber Cable with Connectors (S3200-CN@@@-@@-@@).
Programmable Controllers
CS1G/H
● H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply
Lines)
Applicable
Appearance
Model
S3200-CN@@@-20-20
Controller Link
SYSMAC LINK
S3200-CN@@@-20-25
S3200-CN@@@-25-25
Note: Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.
• Cable Length
• Optical Connector Assembly Tool
The following cable lengths are available: 2 m, 5 m, 15 m, and
20 m. For lengths of 21 m or more, contact your OMRON sales
representative.
• Model Numbers
(1) 2 m, 5 m, 10 m, 15 m, 20 m
(2) 21 m or longer
(e.g.) S3200-CN@@@-20-25
(1)
(1 ) H-PCF
Optical Fiber Cable
(2)
(e.g.) S3200-CN-20-20
(3)
(1)
( 2) Cable length
@@@
Length
201
2m
501
5m
102
10m
152
15m
202
20m
(3) Specify the
cable length
in meters
(3) Connectors (both ends)
No.
Product
name
Applicable Units
This tool is used on site
for mounting crimp-cut
connectors and hard
Optical
plastic-clad silica optical
Fiber
fiber for optical
Assembly
transmission systems of
Tool *
C-series SYSBUS,
SYSMAC LINK, and
Controller Link.
Model
Maker
CAK-0057
Sumitomo Electric
Industries, Ltd.
* There is a risk of quality problems when using cables assembled by typical
users, so we recommend purchasing cables with pre-attached connectors
or having a qualified technician assemble the cables.
Connector lock
20
Full-lock
25
Half-lock
Cable length
● GI Optical Cables
A qualified technician must select, assemble, and install GI
Optical Fiber Cable, so always let an optical cable specialist
handle the GI cable.
Usable Optical Fiber Cables and Optical Connectors
• Optical fiber types: Graded, indexed, multi-mode, all quartz
glass, fiber (GI-type AGF cable)
• Optical fiber construction (core diameter/clad diameter):
62.5/125 µm or 50/125 µm
• Optical fiber optical characteristics of optical fiber: Refer to the
tables.
• Optical connectors: ST connectors (IEC-874-10)
• 50/125 µm AGF Cables
Items
Minimum Typical
Numerical
Aperture (N.A)
---
0.21
Transmission
loss (dB)
---
---
Connection
loss (dB)
Transmission
band width
(MHz·km)
---
---
500
---
Maximum
Remarks
---
---
3.0Lf
0.5 km ≤ Lf
3.0 Lf + 0.2
0.2 km ≤ Lf ≤ 0.5 km
3.0 Lf + 0.4
Lf ≤ 0.2 km
1.0
λ = 0.8 µm, one location
---
λ = 0.8 µm,
Ta = 25°C
λ = 0.85 µm (LD)
Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak
wavelength of the test light source.
• 62.5/125 µm AGF Cables
Items
Minimum Typical
Numerical
Aperture (N.A)
---
0.28
Transmission
loss (dB)
---
---
Connection
loss (dB)
Transmission
band width
(MHz·km)
---
---
200
---
Maximum
Remarks
---
---
3.5Lf
0.5 km ≤ Lf
3.5Lf + 0.2
0.2 km ≤ Lf ≤ 0.5 km
3.5Lf + 0.4
Lf ≤ 0.2 km
1.0
λ = 0.8 µm, one location
---
λ = 0.8 µm,
Ta = 25°C
λ = 0.85 µm (LD)
Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak
wavelength of the test light source.
Programmable Controllers
CS1G/H
41
■ SYSMAC LINK Units
Mountable Racks
CPU Rack
Unit type
Product name
Specifications
CS1W-BC
C200HX/
HG/HE
Expansion
I/O Rack
@@3 @@2
SYSMAC LINK
Unit
Coaxial
(5C-2V cable)
Optical
(H-PCF cable) *2
SYSMAC LINK
Support Board
Data link and
message
communications functions
*1
Yes
*1
Yes
*1
Yes
*1
Yes
No
*1
Yes
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
*1
Yes
No
*1
Yes
*1
Yes
*1
Yes
*1
Yes
No. of
unit
SYSMAC
BUS Slave numbers
allocated
Rack
No
Current
consumption
(A)
5V
26 V
system system
0.48
---
CS1W-SLK21
0.47
---
CS1W-SLK11
1 unit
number’s
words
No
Coaxial
3G8F7-SLK21-E
CS1 CPU
Bus Unit
The 3G8F7-SLK@@ SYSMAC LINK Support Board includes the
FinsGateway communications middleware version 3.
---
Optical (H-PCF cable) *2
F Adapter
F Adapter
Cover
Model
3G8F7-SLK11-E
-----
C1000H-CE001
One Adapter is included with each Coaxial-cable SYSMAC LINK
Unit/Board.
---
A Terminator must be installed at each node on the ends of the
network.
---
C1000H-COV01
Terminator
---
*1.
*2.
C1000H-TER01
Up to four CS1W-SLK11/21 SYSMAC LINK Units can be mounted to the CPU Backplane and Expansion Backplanes of one PLC.
When using wired optical (H-PCF) communications, use the H-PCF Cable or H-PCF Cable with pre-attached connectors.
■ FL-net Units
Mountable Racks
Unit type
Product name
Specifications
CPU Rack
CS1W-BC
@@3 @@2
C200HX/
HG/HE
Expansion
I/O Rack
CS1
Expansion CS1 Longdistance
Rack
Expansion
CS1W-BI
Rack
@@3 @@2
No. of
unit
SYSMAC
BUS Slave numbers
allocated
Rack
Current
consumption
(A)
Model
5V
26 V
system system
FL-net Unit
CS1 CPU
Bus Unit
FL-net (OPCN-2) Ver. 2
specifications
100BASE-TX Cable
*
Yes
*
Yes
No
*
Yes
*
Yes
*
Yes
No
1 unit
number’s
words
0.38
---
CS1W-FLN22
* Up to four CS1W-FLN22 FL-net Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
42
Programmable Controllers
CS1G/H
■ DeviceNet Unit
Mountable Racks
Unit type
Product
name
CPU Rack
Communications
functions
Specifications
CS1W-BC
@@3 @@2
DeviceNet
Unit
CS1 CPU
Bus Unit
Functions as
master and/or
slave; allows
control of
32,000 points
max. per
master.
• Remote I/O Master
communications
(Fixed or user-set
allocation)
• Remote I/O Slave
communications
(Fixed or user-set
allocation)
• Message
communications
Yes
CS1
Expansion CS1 Longdistance
Rack
Expansion
CS1W-BI
Rack
@@3 @@2
C200HX/
HG/HE
Expansion
I/O Rack
Yes
No
Yes
Yes
No. of
unit
SYSMAC
BUS Slave numbers
allocated
Rack
Yes
Current
consumption
(A)
Model
5V
26 V
system system
No
1 unit
number’s
words
0.29
---
CS1W-DRM21-V1
Maximum number of Units: 16 if Configurator is used
■ CompoNet Master Unit
Specifications
Unit type
Product
name
Communications
functions
Mountable Racks
Maximum number
of I/O points per
Master
CPU Rack
CS1W-BC
@@3 @@2
CompoNet
Master Unit
CS1
Special
I/O Unit
Word Slave Units:
1,024 inputs and
1,024 outputs
• Remote I/O
(2,048 I/O points
communications
total)
• Message
Bit Slave Units:
communications
256 inputs and
256 outputs
(512 I/O points
total)
Yes
C200HX/
HG/HE
Expansion
I/O Rack
Yes
No
CS1
Expansion CS1 Long- SYSMAC
distance
Rack
BUS Slave
Expansion
Rack
CS1W-BI
Rack
@@3 @@2
Yes
Yes
Yes
No
No. of
unit
numbers
allocated
1, 2, 4, or
8 unit
numbers’
words
(variable)
Current
consumption
(A)
Model
5V
26 V
system system
0.40
---
CS1W-CRM21
■ CompoBus/S Master Unit
Specifications
Unit type
Product
name
Mountable Racks
Maximum number
Communications
of I/O points per
functions
Master
CPU Rack
CS1W-BC
@@3 @@2
CS1
Special
I/O Unit
CompoBus/
S Master
Unit
Remote I/O
communications
C200HX/
HG/HE
Expansion
I/O Rack
CS1
Expansion CS1 Long- SYSMAC
distance
Rack
BUS Slave
Expansion
CS1W-BI
Rack
Rack
@@3 @@2
256 max.
(128 inputs and 128
outputs)
No. of
unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
2 unit
numbers’
words
Yes
Yes
No
Yes
Yes
Yes
No
128 max.
(64 inputs and 64
outputs)
0.15
---
CS1W-SRM21
1 unit
number’s
words
■ ID Sensor Units
Mountable Racks
Unit type
Product
name
Connecting ID
System
Number
of RW
Heads
External
power
supply
CPU Rack
CS1W-BC
@@3 @@2
ID Sensor
Units
CS1
Expansion CS1 Longdistance
Rack
Expansion
CS1W-BI
Rack
@@3 @@2
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Current
consumption
(A)
Model
5V
26 V
system system
*
1
Not
required
Yes
Yes
No
Yes
Yes
Yes
No
1 unit
number’s
words
0.26
0.13
CS1W-V680C11
2
24 VDC
Yes
Yes
No
Yes
Yes
Yes
No
2 unit
numbers’
words
0.32
---
CS1W-V680C12
1
Not
required
Yes
Yes
No
Yes
Yes
Yes
No
1 unit
number’s
words
0.26
0.12
CS1W-V600C11
2
24 VDC
Yes
Yes
No
Yes
Yes
Yes
No
2 unit
numbers’
words
0.32
---
CS1W-V600C12
V680-series RFID
system
CS1
Special
I/O Unit
C200HX/
HG/HE
Expansion
I/O Rack
V600-series RFID
system
* The current consumption is 0.28 A when connected to the V680-H01. For details, refer to the V680 Series RFID System Catalog (Cat. No. Q151).
Programmable Controllers
CS1G/H
43
■ GP-IB Interface Unit
Mountable Racks
CPU Rack
Unit type
Product name
Specifications
CS1W-BC
@@3
@@2
*
Yes
*
Yes
CS1
Expansion
Rack
C200HX/
HG/HE
Expansion
I/O Rack
CS1W-BI
@@3
@@2
*
Yes
*
Yes
CS1 Longdistance
Expansion
Rack
SYSMAC
BUS Slave
Rack
Yes
No
No. of unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
GP-IB
Interface Unit
CS1
Special
I/O Unit
Master or slave mode
provided.
No
1 unit
number’s
words
0.33
---
CS1W-GPI01
* Up to four GP-IP Interface Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
■ SPU Unit (High-speed Data Storage Unit)
Mountable Racks
Specifications
CPU Rack
Unit type
Product name
PC Card slot
SPU Unit
(High-speed
Data Storage
Unit)
1 PC Card Type II
slot Insert an
OMRON
HMC-EF@@@ to
use the Memory
Card.
Ethernet
LAN port
CS1W-BC
C200HX/
HG/HE
Expansion
I/O Rack
@@3 @@2
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
SYSMAC
BUS Slave
Rack
Yes
No
Yes
Yes
Yes
No
Model
5V
26 V
system system
1 port
(10/100
BASE-TX)
Yes
Current
consumption
(A)
0.56
---
CS1W-SPU01-V2
0.70
---
CS1W-SPU02-V2
1 unit
number’s
words
2 ports
(10/100
BASE-TX)
SPUConsole
Support
Software *
Functions: Setting the
High-speed Data Storage Unit's
unit settings, sampling settings,
etc. (The software is required to
make the High-speed Data
Storage Unit's settings.)
OS: Windows 7/Windows 8/
Windows 8.1/Windows 10
SPU Unit
SPU Data
Management
Middleware
Functions: Automatically
uploads collected data files from
the SPU Unit to the computer,
and can also register the data in
a database.
OS: Windows XP/
Windows Vista/
Windows 7/Windows 8
---
Flash memory:
128 MB
---
---
HMC-EF183
---
---
HMC-EF283
---
---
HMC-EF583
---
---
HMC-AP001
CS1 CPU
Bus Unit
Memory
Cards
Flash memory:
256 MB
Flash memory:
512 MB
---
Note:
A memory
Card is
required to
collect
data.
Memory Card Adapter
(for a computer’s PCMCIA slot)
* SPU-Console version lower than version 2.0 cannot be connected to SPU Units with unit version 2.0 or later.
44
No. of unit
numbers
allocated
Programmable Controllers
CS1G/H
---
WS02-SPTC1-V2
1 license
WS02-EDMC1-V2
5 licenses
WS02-EDMC1-V2L05
C200H Special I/O Units
■ Temperature Sensor Units
Specifications
Unit type
Product
name
I/O
points
Signal
range
selection
Mountable Racks
CPU Rack
Signal
range
ConverExternal
sion
connection
speed
CS1W-BC
@@3 @@2
C200H
Special
I/O Unit
Thermocouple
K, J
4
4
Tempera- inputs common
ture
Sensor
Units
4
4
inputs common
4.8 s
max.
Removable
(when 4
terminal
inputs
block
are used
per Unit)
Thermometer
JPt100
Thermometer
Pt100
4
4
inputs common
CS1
Expansion CS1 LongRack
distance
Expansion
CS1W-BI
Rack
@@3 @@2
C200HX/
HG/HE
Expansion
I/O Rack
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Yes
No
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
No
Yes
1 unit
number’s
words
Current
consumption
(A)
Model
5V
26 V
system system
0.45
---
C200H-TS001
0.45
---
C200H-TS101
0.45
---
C200H-TS102
■ Analog Input Units
Specifications
Product
Unit type
name
Signal
I/O
range
points selection
Analog
Input
Units
C200H
Special
I/O Unit
8
8
cominputs
mon
Signal
range
Mountable Racks
CS1
CPU Rack C200HX/
Expansion CS1 LongConverResoExternal
HG/HE
distance
Rack
sion
lution
connection
Expansion
Expansion
CS1W-BC
CS1W-BI
speed
I/O Rack
Rack
@@3 @@2
@@3 @@2
1 to 5 V,
4 to 20 mA,
1 ms/
1/4000
0 to 10 V,
input
-10 to 10 V
Removable
terminal
Yes
block
No
Yes
Yes
No
No
Current
No. of
consumption
SYSMAC unit
(A)
BUS
numbers
Slave
allocated
5V
26 V
Rack
system system
Yes
1 unit
number’s
words
0.10
0.10
Model
C200H-AD003
■ Analog Output Units
Specifications
Unit type
Product
name
Analog
Output
Units
C200H
Special
I/O Unit
I/O
points
Signal
range
selection
Signal
range
Mountable Racks
CS1
CPU Rack C200HX/
Expansion CS1 LongConverRack
HG/HE
distance
ResoluExternal
sion
tion
connection
Expansion
Expansion
speed
CS1W-BC
CS1W-BI
I/O Rack
Rack
@@3 @@2
@@3 @@2
8
8
indepenoutputs
dent
1 to 5 V,
1 ms/
0 to 10 V,
1/4000
output
-10 to 10 V
8
8
indepenoutputs
dent
4 to 20 mA
1/4000
1 ms/
output
Yes
No
Yes
Yes
No
No
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Yes
Removable
terminal
block
Current
consumption
(A)
Model
5V
26 V
system system
0.10
0.20
C200H-DA003
0.10
0.25
C200H-DA004
1 unit
number’s
words
Yes
No
Yes
Yes
No
No
Yes
■ Analog I/O Units
Specifications
Unit type
Product
name
Analog
I/O
Units
C200H
Special
I/O Unit
I/O
points
Signal
range
selection
Signal
range
CS1
CPU Rack C200HX/
Expansion CS1 LongConverRack
HG/HE
distance
ResoluExternal
sion
Expansion
Expansion
tion
connection
speed
CS1W-BC
CS1W-BI
I/O Rack
Rack
@@3 @@2
@@3 @@2
2
independent
1 to 5 V,
0 to 10 V,
1 ms/
1/4000
-10 to 10 V,
input
4 to 20 mA
2
2
indepenoutputs
dent
1 to 5 V,
0 to 10 V,
1 ms/
1/4000
-10 to 10 V,
output
4 to 20 mA
2
inputs
Mountable Racks
Removable
terminal
Yes
block
No
Yes
Yes
No
No
No. of
SYSMAC unit
BUS
numbers
Slave
allocated
Rack
Yes
1 unit
number’s
words
Programmable Controllers
Current
consumption
(A)
Model
5V
26 V
system system
0.10
0.20
C200H-MAD01
CS1G/H
45
■ Temperature Control Units
Specifications
Unit type
Product name No. of
loops
Temperature
Control Units
C200H
Special
I/O Unit
Mountable Racks
CS1
Expansion CS1 LongCPU Rack C200HX/
SYSMAC
Rack
Temperature
HG/HE
distance
Control output
BUS Slave
sensor inputs
Expansion
Expansion
CS1W-BC
CS1W-BI
Rack
I/O Rack
Rack
@@3 @@2
@@3 @@2
No. of
unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
Thermocouples Open-collector
2 loops (R, S, K, J, T, E, NPN outputs
B, N, L, or U)
(pulses)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC001
Thermocouples Voltage
2 loops (R, S, K, J, T, E, outputs
B, N, L, or U)
(pulses)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC002
Thermocouples Current
2 loops (R, S, K, J, T, E, outputs
B, N, L, or U)
(linear)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC003
2 loops
Platinum
resistance
thermometers
(JPt00, Pt100)
ON/OFF
transistor
outputs
(pulses)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC101
2 loops
Platinum
resistance
thermometers
(JPt00, Pt100)
ON/OFF
voltage
outputs
(pulses)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC102
2 loops
Platinum
resistance
thermometers
(JPt00, Pt100)
ON/OFF
current
outputs
(linear)
Yes
No
Yes
Yes
No
No
Yes
0.33
---
C200H-TC103
Connecting Cable length: 2 m
Cables
Cable length: 4 m
1 unit
number’s
words
---
C200H-CN225
---
C200H-CN425
■ Heat/Cool Temperature Control Units
Specifications
Unit type
Product name No. of
loops
Heat/Cool
Temperature
Control Units
C200H
Special
I/O Unit
Temperature
sensor inputs
Mountable Racks
Control
output
Heating
output:
Voltage output
Thermocouples (pulses),
2 loops (R, S, K, J, T, E, Cooling
B, N, L, or U)
output:
Open-collector
NPN outputs
(pulses)
CS1
Expansion CS1 LongCPU Rack C200HX/
SYSMAC
Rack
HG/HE
distance
BUS Slave
Expansion
Expansion
CS1W-BC
CS1W-BI
Rack
I/O Rack
Rack
@@3 @@2
@@3 @@2
Yes
No
Connecting Cable length: 2 m
Cables
Cable length: 4 m
46
Programmable Controllers
CS1G/H
Yes
Yes
No
No
Yes
No. of
unit
numbers
allocated
1 unit
number’s
words
Current
consumption
(A)
Model
5V
26 V
system system
0.33
---
C200H-TV002
---
C200H-CN225
---
C200H-CN425
■ PID Control Units
Specifications
Unit type
Product name No. of
loops
PID Control
Units
C200H
Special
I/O Unit
Temperature
sensor input
Voltage input/
current input
2 loops (4 to 20 mA,
1 to 5 V, 0 to 5 V,
or 0 to 10 V)
Mountable Racks
Control
output
Current
outputs
(linear)
CS1
CPU Rack C200HX/
Expansion CS1 LongSYSMAC
Rack
HG/HE
distance
BUS Slave
Expansion
Expansion
CS1W-BC
CS1W-BI
Rack
I/O Rack
Rack
@@3 @@2
@@3 @@2
Yes
No
Yes
Yes
No
Connecting Cable length: 2 m
Cables
Cable length: 4 m
No
Yes
No. of
unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
1 unit
number’s
words
0.33
---
C200H-PID03
---
C200H-CN225
---
C200H-CN425
■ High-speed Counter Units
Specifications
Unit type
Product name Number Encoder A and
of
B input, pulse
counters input, Z signal
High-speed
Counter Units
C200H
Special I/
O Unit
Voltage input: 12
or 24 VDC
Mountable Racks
CS1
Expansion CS1 LongCPU Rack C200HX/
Maximum
SYSMAC
Rack
HG/HE
distance
counting
BUS Slave
Expansion
Expansion
CS1W-BC
CS1W-BI
speed
Rack
I/O Rack
Rack
@@3 @@2
@@3 @@2
Current
consumption
(A)
Model
5V
26 V
system system
50 kHz
2
Yes
RS-422 line
driver
No. of
unit
numbers
allocated
No
Yes
Yes
No
No
Yes
1 unit
number’s
words
0.40
---
C200H-CT021
75 kHz
Programmable Controllers
CS1G/H
47
■ ASCII Units
Mountable Racks
Unit type
Product name
CS1
Expansion CS1 LongCPU Rack C200HX/
SYSMAC
Rack
HG/HE
distance
BUS Slave
Expansion
Expansion
CS1W-BC
CS1W-BI
Rack
I/O Rack
Rack
@@3 @@2
@@3 @@2
Specifications
No. of
unit
numbers
allocated
Current
consumption
(A)
Model
5V
26 V
system system
ASCII Units
User memory area: 200 Kbytes
Shared memory: Provided
(general-purpose area: 90
words)
RS-232C x 2 ports
C200H
Special
I/O Unit
RS-422A Adapter
Yes
No
Converts RS-232C to RS-422A/
RS-485 format.
RS-232C/RS-422A One RS-232C port
Link Adapter
One RS-422 terminal block
48
Programmable Controllers
CS1G/H
Yes
Yes
No
No
Yes
1 unit
number’s
words
0.25
---
C200H-ASC11
---
---
CJ1W-CIF11
---
---
NT-AL001
Replacing C200H I/O Units
This section shows the corresponding CS1 I/O models and notes for replacing C200H I/O Units.
16-point DC Input Units
Item
Model number
Description
64-point DC Input Units
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-ID212
CS1W-ID211
Description
Notes
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-ID218
CS1W-ID231
32-point DC Input Units with connectors. The connectors,
the pin arrangement, and the input specifications are the
same.
Item
Model number
Description
Model number
Description
The internal 5-V current consumption increases (from
100mA to 150mA). Check that the increased current is
within the range of the power supply.
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-ID216
CS1W-ID231
32-point DC Input Units with connectors. The connectors
and the pin arrangement are the same. The input current
increases, allowing use with a wider range of devices.
There are 2 commons instead of 1. Connect where
necessary.
Notes
C200H-ID219
CS1W-ID261
64-point DC Input Units with connectors. The connectors,
the pin arrangement, and the input specifications are the
same.
The internal 5-V current consumption increases (from
120mA to 150mA). Check that the increased current is
within the range of the power supply.
The input specifications change (e.g., the impedance
decreases and the input current increases from 4.1mA to
6mA.) Check that correct operation is possible in cases
where changes in input specifications may influence
operation.
The internal 5-V current consumption increases (from
100mA to 150mA). Check that the increased current is
within the range of the power supply.
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-ID217
CS1W-ID261
64-point DC Input Units with connectors. The connectors
and the pin arrangement are the same. The input current
increases, allowing use with a wider range of devices.
There are 4 commons instead of 2. Connect where
necessary.
Notes
32-point DC Input Units (cntd.)
Item
Corresponding
CS1 I/O Unit
There are 4 commons instead of 2. Connect where
necessary.
There are 2 commons instead of 1. Connect where
necessary.
Notes
C200H I/O Unit
64-point DC Input Units (cntd.)
32-point DC Input Units
Model number
Description
The impedance increases (from 3kΩ to 3.3kΩ). Check that
correct operation is possible in cases where increased
impedance may influence operation.
The internal 5-V current consumption increases (from
10mA to 100mA). Check that the increased current is
within the range of the power supply.
Item
Model number
16-point DC Input Units with terminal blocks
The terminal arrangement must be changed.
Notes
Item
The input specifications change (e.g., the impedance
decreases and the input current increases from 4.1mA to
6mA.) Check that correct operation is possible in cases
where changes in input specifications may influence
operation.
The internal 5-V current consumption increases (from
100mA to 150mA). Check that the increased current is
within the range of the power supply.
16-point Sinking Transistor Output Units
Item
Model number
Description
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-OD212
CS1W-OD211
16-point Transistor Output (sinking) Units with terminal
blocks. The output current capacity increases (from 0.3A
per point and 4.8A per Unit to 0.5A per point and 8A per
Unit). The rated voltage range also increases (from 24V to
any voltage in the range 12 to 24V.)
The terminal arrangement must be changed.
Notes
The output specifications change. Check that correct
operation is possible in cases where changes in output
specifications may influence operation. (Residual voltage
increases from 0.8V to 1.5V, ON response time increases
from 0.1ms to 0.5ms, OFF response time increases from
0.3ms to 1ms.)
Programmable Controllers
CS1G/H
49
C200H???????????????????
16-point Sourcing Transistor Output Units
Item
Model number
Description
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-OD21A *
CS1W-OD212
16-point Transistor Output (sourcing) Units with terminal
blocks.
32-point Sourcing Transistor Output Units
Item
Model number
Description
The terminal arrangement must be changed.
Notes
The internal 5-V current consumption increases (from
160mA to 170mA). The external 24-V power supply
current also increases (from 35mA to 40mA). Check that
the increased current is within the range of the power
supply.
There are no alarm output contacts. Use the alarm bits in
the Auxiliary Area.
* Discontinuation models in March 2015.
Notes
Model number
Description
Corresponding
CS1 I/O Unit
C200H-OD218
CS1W-OD231
Notes
The output specifications change. Check that correct
operation is possible in cases where changes in output
specifications may influence operation. (Residual voltage
increases from 0.8V to 1.5V, ON response time increases
from 0.1ms to 0.5ms, OFF response time increases from
0.3ms to 1ms.)
64-point Sinking Transistor Output Units
Item
Description
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-OD219
CS1W-OD261
64-point Transistor Output (sinking) Units with connectors.
The connectors and the pin arrangement are the same.
The output current capacity increases (from 100mA to
0.3A per point, 1.6A per common, and 6.4A per Unit). The
load voltage range changes from 4.5 to 26.4V to 10.2 to
26.4V.
There are 4 commons instead of 2. Connect where
necessary.
32-point Transistor Output (sinking) Units with connectors.
The connectors and the pin arrangement are the same.
The output current capacity increases (from 100mA to
0.5A per point, 2.5A per common, and 5A per Unit). The
load voltage range changes from 4.5 to 26.4V to 10.2 to
26.4V.
There are 2 commons instead of 1. Connect where
necessary.
CS1W-OD232
* C200H-OD21B was discontinued at the end of March 2016.
Model number
C200H I/O Unit
C200H-OD21B *
32-point Transistor Output (sourcing) Units with
connectors. The connectors and the pin arrangement are
the same.
The internal 5-V current consumption increases (from
180mA to 270mA). Check that the increased current is
within the range of the power supply.
32-point Sinking Transistor Output Units
Item
Corresponding
CS1 I/O Unit
There are 2 commons instead of 1. Connect where
necessary.
The output capacity changes (from 1A per point and 4A
per Unit to 0.5A per point and 5A per Unit). Check that
correct operation is possible in cases where changes in
output capacity may influence operation.
The output specifications change. Check that correct
operation is possible in cases where changes in output
specifications may influence operation. (Residual voltage
increases from 0.8V to 1.5V, ON response time increases
from 0.1ms to 0.5ms, OFF response time increases from
0.3ms to 1ms.)
C200H I/O Unit
Notes
The output specifications change. Check that correct
operation is possible in cases where changes in output
specifications may influence operation. (Residual voltage
increases from 0.8V to 1.5V, ON response time increases
from 0.1ms to 0.5ms, OFF response time increases from
0.4ms to 1ms.)
Replacement is not possible for applications with an output
load range of 4.5 to 10.2V.
The output specifications change. Check that correct
operation is possible in cases where changes in output
specifications may influence operation. (Residual voltage
increases from 0.8V to 1.5V, ON response time increases
from 0.1ms to 0.5ms, OFF response time increases from
0.4ms to 1ms.)
The internal 5-V current consumption increases (from
270mA to 390mA). Check that the increased current is
within the range of the power supply.
Replacement is not possible for applications with an output
load range of 4.5 to 10.2V.
16-point 100-VAC Input Units
The internal 5-V current consumption increases (from
180mA to 270mA). Check that the increased current is
within the range of the power supply.
Item
Model number
Description
C200H I/O Unit
Corresponding
CS1 I/O Unit
C200H-IA122/122V
CS1W-IA111
16-point 100-VAC Input Units with terminal blocks.
100-VDC input also possible.
The terminal arrangement must be changed.
Notes
The input specifications change. Check that correct
operation is possible in cases where changes in input
specifications may influence operation. (ON voltage
increases from 60VAC min. to 65VAC min. and the input
impedance (50Hz) increases from 9.7kΩ to 10kΩ.)
The internal 5-V current consumption increases (from
10mA to 110mA). Check that the increased current is
within the range of the power supply.
50
Programmable Controllers
CS1G/H
MEMO
51
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.
br
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Authorized Distributor:
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification
Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration • Runtime
P062I-E-02
Note: Specifications are subject to change.
© 2018 Omron. All Rights Reserved.
Printed on recycled paper.
Printed in U.S.A.