CJ/CS Series ID Sensor Unit
CJ1W-V680C11/-V680C12
CS1W-V680C11/-V680C12
CSM_C_1W-V680C1_DS_E_1_2
Communication Unit Dedicated for RFID V680
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 8 kbytes.
Features
• Easy reading and writing of data by simply setting parameters in PLC memory area.
• Simpler device configuration compared to serial communication allows faster data processing.
• Function Block (FB) library in Ladder Program facilitates generation of communication programs.
Note: For system configuration, refer to V680-series catalog (Q151). For specification of controllers, refer to the manual of each controller.
Ordering Information
Type
Appearance
Connected ID System
External
power supply
1 Head
CJ
Special
I/O Unit
V680
Series
CS
Special
I/O Unit
Appearance
Current consumption (A)
Model
5V
24 V
External
1 unit
number
0.26
0.13 *
−
CJ1W-V680C11
2 unit
number
0.32
0.26
−
CJ1W-V680C12
−
2 Heads
Type
No. of unit
numbers
used
External
power supply
No. of unit
numbers
used
1 Head
−
2 Heads
24 VDC
Connected ID System
Current consumption (A)
Model
5V
26 V
External
1 unit
number
0.26
0.13 *
−
CS1W-V680C11
2 unit
number
0.32
−
0.36
CS1W-V680C12
V680
Series
* When connected to the V680-H01-V2: 0.28 A
1
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
General Specification
Item
Model
CJ1W-V680C11
Internal: 5 V 0.26 A
Current
Internal:
con0.13 A *
24 V/26 V
sumption
External: 24 V −
CS1W-V680C11
CS1W-V680C12
0.26 A
0.32 A
0.26 A
0.13 A *
−
−
−
0.36 A
Ambient operating
temperature
0 to 55°C
Ambient storage temperature
−20°C to 75°C
Ambient operating humidity
10% to 90% (with no condensation)
Insulation resistance
20 mΩ min. at 500 VDC
Dielectric strength
1,000 VAC for 1 minute
Degree of protection
Mounted in panel (IP30)
Vibration resistance
10 to 57 Hz variable vibration, 0.075-mm double amplitude and 57 to 150 Hz variable vibration at 9.8 m/s2
acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each
Shock resistance
147 m/s2 in X, Y, and Z directions 3 times each
Appearance
31 × 65 × 90 mm (excluding protrusions)
35 × 130 × 101 mm (excluding protrusions)
Weight
120 g max.
180 g max.
* When connected to the V680-H01-V2: 0.28 A.
2
CJ1W-V680C12
0.32 A
130 g max.
300 g max.
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
Performance Specifications
For CJ1 Series
Item
Model
Unit classification
CJ1W-V680C11
CJ1W-V680C12
Special I/O Unit
Influence on CPU Unit's
0.15 ms
cycle time
0.3 ms
Mounting location
CJ1-series CPU Rack or CJ1-series Expansion Rack
(Cannot be mounted to C200H Expansion I/O Racks or SYSMAC BUS Slave Racks.)
Connectable Antennas
V680-series Amplifiers and Antennas *1
Applicable RF Tags
V680-series RF Tags
No. of allocated units
1
2
No. of allocated words
10 words
20 words
Control protocol
Special protocol
Special I/O Unit Area in Constant data
CIO Area: CIO 2000 to exchange of 10 words/
Unit
CIO 2959
Data exchange
methods with CPU Unit
CPU Unit to ID
Sensor Unit
Unit controls, communications
processing specification, data
storage area specification
ID Sensor Unit to
CPU Unit
Unit information, results
information, processing results
monitor
100 words/Unit
Special I/O Unit words in
transferred when power CPU Unit to ID
DM Area: D20000 to
Sensor Unit
is turned ON or when
D29599
restarting the Unit
Data transfer quantity
2,048 bytes max. (160 bytes/scan) *2
System Settings, Auto Wait Time
Setting, Write Protection Disable
Setting, Antenna Connection
Setting, Results Monitor Output,
Test Setting, Run/Test Switching
Method Setting
2,048 bytes max./channel (160 bytes/scan) *2
Run Mode
Operating modes
Diagnostic functions
Test Mode
• Communications tests
• Distance level measurements
• Read speed level measurements
• Write speed level measurements
• Noise level measurements
• Communications success rate measurements
(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error
*1. V680-H01 and V680-H01-V2 can be connected to 1CH-type ID Sensor Units only. They are not supported by 2CH-type ID Sensor Units.
*2. If using Intelligent I/O Instructions is specified as the data transfer method, up to 2,048 bytes can be transferred in one scan.
3
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
For CS1 Series
Item
Model
CS1W-V680C11
CS1W-V680C12
Unit classification
Special I/O Unit
Influence on CPU
Unit's cycle time
0.15 ms
Mounting location
CS1-series CPU Rack or CS1-series Expansion Rack
(Cannot be mounted to C200H Expansion I/O Racks or SYSMAC BUS Slave Racks.)
Connectable Antennas
V680-series Amplifiers and Antennas *1
Applicable RF Tags
V680-series RF Tags
No. of allocated units
1
2
No. of allocated words
10 words
20 words
Control protocol
Special protocol
0.3 ms
Special I/O Unit Area in Constant data
CIO Area: CIO 2000 to exchange of 10 words/
Unit
CIO 2959
Data exchange
methods with CPU Unit
CPU Unit to ID
Sensor Unit
Unit controls, communications
processing specification, data
storage area specification
ID Sensor Unit to
CPU Unit
Unit information, results
information, processing results
monitor
100 words/Unit
Special I/O Unit words in
transferred when power CPU Unit to ID
DM Area: D20000 to
Sensor Unit
is turned ON or when
D29599
restarting the Unit
Data transfer quantity
2,048 bytes max. (160 bytes/scan) *2
System Settings, Auto Wait Time
Setting, Write Protection Disable
Setting, Antenna Connection
Setting, Results Monitor Output,
Test Setting, Run/Test Switching
Method Setting
2,048 bytes max./channel (160 bytes/scan) *2
Run Mode
Operating modes
Diagnostic functions
Test Mode
• Communications tests
• Distance level measurements
• Read speed level measurements
• Write speed level measurements
• Noise level measurements
• Communications success rate measurements
(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error
*1. V680-H01 and V680-H01-V2 can be connected to 1CH-type ID Sensor Units only. They are not supported by 2CH-type ID Sensor Units.
*2. If using Intelligent I/O Instructions is specified as the data transfer method, up to 2,048 bytes can be transferred in one scan.
4
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
For NJ Series
Item
Model
CJ1W-V680C11
Unit classification
Special I/O Unit
Mounting location
NJ-series CPU Rack or NJ-series Expansion Rack
Connectable Antennas
V680-series Amplifiers and Antennas *
Applicable RF Tags
V680-series RF Tags
CJ1W-V680C12
Run Mode
Operating modes
Test Mode
• Communications tests
• Distance level measurements
• Read speed level measurements
• Write speed level measurements
• Noise level measurements
• Communications success rate measurements
Data exchange
Data exchange by using I/O ports
methods with CPU Unit
Diagnostic functions
(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error
* V680-H01 and V680-H01-V2 can be connected to 1CH-type ID Sensor Units only. They are not supported by 2CH-type ID Sensor Units.
5
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
Communications Function Specifications
Item
Model
CJ1W-V680C11
CJ1W-V680C12
(1) RF Tag Communications Speed (Normal Mode or High-speed Mode)
(2) Write Verification Processing
(3) Auto Wait Time Setting
(4) UID Addition Setting
(5) Write Protection Setting
(6) Antenna Connection Setting (One-channel ID Sensor Unit (CJ1W-V680C11))
(7) Results Monitor Setting
Communications
control
Read
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Commands
Read
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Copy
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Single trigger
Single auto
Repeat auto
FIFO trigger *
FIFO repeat *
Multi-access trigger *
Multi-access repeat *
Communications
specification
* FIFO trigger, FIFO repeat, Multi-access trigger, and Multi-access repeat specification cannot be used for communicating with V680-D1KP@@ RF Tags.
Item
Communications
control
Commands
Communications
specification
Model
CS1W-V680C11
CS1W-V680C12
(1) RF Tag Communications Speed (Normal Mode or High-speed Mode)
(2) Write Verification Processing
(3) Auto Wait Time Setting
(4) UID Addition Setting
(5) Write Protection Setting
(6) Antenna Connection Setting (One-channel ID Sensor Unit (CS1W-V680C11))
(7) Results Monitor Setting
Read
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Read
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Copy
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Single trigger
Single auto
Repeat auto
FIFO trigger *
FIFO repeat *
Multi-access trigger *
Multi-access repeat *
* FIFO trigger, FIFO repeat, Multi-access trigger, and Multi-access repeat specification cannot be used for communicating with V680-D1KP@@ RF Tags.
6
CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12
Connectable Units
When using V680-HS51/-HS52/-HS63/-HS65 Antenna
NJ System
Expansion
CPU unit
unit
4 units
6 units
2 units
3 units
N/A
N/A
N/A
N/A
Model
CJ1W-V680C11
CJ1W-V680C12
CS1W-V680C11
CS1W-V680C12
CJ System
Expansion
CPU unit
unit
4 units
4 units
2 units
2 units
N/A
N/A
N/A
N/A
CS System
Expansion
CPU unit
unit
N/A
N/A
N/A
N/A
9 units
9 units
10 units
10 units
CJ System
Expansion
CPU unit
unit
2 units
1 unit
N/A
N/A
CS System
Expansion
CPU unit
unit
N/A
N/A
4 units
4 units
When using V680-H01-V2 Antenna
NJ System
Expansion
CPU unit
unit
2 units
2 units
N/A
N/A
Model
CJ1W-V680C11
CS1W-V680C11
Dimensions
(unit: mm)
CS1W-V680C11
CJ1W-V680C11
Six operation indicators
65
Six operation indicators
123
Switches
4.5
2.7
Switches
0
1
18.1
90
4.7
2.7
31
130
17.3
Connector
Connector
101
35
CS1W-V680C12
CJ1W-V680C12
Eight operation indicators
123
Eight operation indicators
2.7
4.5
Switches
Switches
65
0
4.7
90
18.1
1
130
17.3
25
29.2
51
Connectors
2.7
31
Connectors
3.6
35
8
15
Terminals
101
With cover
mounted: 16.5
Related Manuals
Man. No
Model
Z271
V680 series
CS1W-V680C11
CS1W-V680C12
CJ1W-V680C11
CJ1W-V680C12
Z317
V680 series
CJ1W-V680C11
CJ1W-V680C12
Manual name
ID sensor units
User’s Manual
ID sensor units
User’s Manual
Application
Description
When connecting to OMRON
PLC CS/CJ-series
Describes the following for the main ID Sensor Unit:
• System configuration
• Data exchange with CPU units
• Functions of ID Sensor Unit
• Controlling ID Sensor Unit
• Operations when alarm is triggered
When connecting to OMRON
PLC NJ-series
Describes the following for the main ID Sensor Unit:
• System configuration
• Data exchange with CPU units
• Functions of ID Sensor Unit
• Controlling ID Sensor Unit
• Operations when alarm is triggered
7
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2018.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2018 All Right Reserved.